Sample records for analyses final comparison

  1. KEY COMPARISON Final report on international comparison CCQM-K71: Measurement of stack gas

    NASA Astrophysics Data System (ADS)

    Nieuwenkamp, G.; van der Veen, A. M. H.; Wessel, R. M.; Qiao, Han; Oh, Sang-Hyub; Kim, Byung-Moon; Kim, Kwang-Sub; Pérez Castorena, Alejandro; Ramírez Nambo, Carlos; Koelliker Delgado, Jorge; Serrano Caballero, Victor M.; Rangel Murillo, Francisco; Avila Salas, Manuel de Jesus; Dias, Florbela; Baptista, Gonçalo; Konopelko, L. A.; Kustikov, Y. A.; Pankratov, V. V.; Selyukov, D. N.; Balandovich, V. S.; Vishnyakov, I. M.; Pavlov, M. V.; Maltsev, M. A.; Botha, Angelique; Valkova, Miroslava; Stovcik, Viliam; Musil, Stanislav; Milton, M. J. T.; Uprichard, I. J.; Vargha, G. M.; Guenther, F.; Gameson, L.; da Cunha, V.

    2010-01-01

    Industrial stack gas emission measurements are important for process control, control of air pollution, and for implementing legislation regarding carbon dioxide emission rights. Measurements are typically performed using a range of process analysers for carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NOx), sulphur dioxide (SO2) and miscellaneous hydrocarbons. The calibration of these analysers is often performed using a series of binary mixtures of each component in nitrogen. For reasons of efficiency as well as a better match with true stack gas, the use of multi-component mixtures for this purpose would be preferred. The aim of this key comparison is to evaluate the measurement capabilities of national metrology institutes for carbon monoxide, carbon dioxide, nitrogen monoxide, sulphur dioxide and propane in nitrogen. Ten laboratories participated in the key comparison and one in the associated study. The key comparison reference value is based on the gravimetric preparation data. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Academic Performance and Pass Rates: Comparison of Three First-Year Life Science Courses

    ERIC Educational Resources Information Center

    Downs, C. T.

    2009-01-01

    First year students' academic performance in three Life Science courses (Botany, Zoology and Bioscience) was compared. Pass rates, as well as the means and distributions of final marks were analysed. Of the three components (coursework, practical and theory examinations) contributing to the final mark of each course, students performed best in the…

  3. Final report on EURAMET.L-S21: `Supplementary comparison of parallel thread gauges'

    NASA Astrophysics Data System (ADS)

    Mudronja, Vedran; Šimunovic, Vedran; Acko, Bojan; Matus, Michael; Bánréti, Edit; István, Dicso; Thalmann, Rudolf; Lassila, Antti; Lillepea, Lauri; Bartolo Picotto, Gian; Bellotti, Roberto; Pometto, Marco; Ganioglu, Okhan; Meral, Ilker; Salgado, José Antonio; Georges, Vailleau

    2015-01-01

    The results of the comparison of parallel thread gauges between ten European countries are presented. Three thread plugs and three thread rings were calibrated in one loop. Croatian National Laboratory for Length (HMI/FSB-LPMD) acted as the coordinator and pilot laboratory of the comparison. Thread angle, thread pitch, simple pitch diameter and pitch diameter were measured. Pitch diameters were calibrated within 1a, 2a, 1b and 2b calibration categories in accordance with the EURAMET cg-10 calibration guide. A good agreement between the measurement results and differences due to different calibration categories are analysed in this paper. This comparison was a first EURAMET comparison of parallel thread gauges based on the EURAMET ctg-10 calibration guide, and has made a step towards the harmonization of future comparisons with the registration of CMC values for thread gauges. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on AFRIMETS comparison of liquid in glass thermometer calibrations from -35 °C to 250 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans; Kebede Ejigu, Efrem; Madiba, Tshifhiwa; du Clou, Sven; Chibaya, Blessing; Mwazi, Victor; Kajane, Tebogo; Mundembe, Victor; Kwong, Christian Ng Ha; Madeleine, Gilbert

    2017-01-01

    A Regional Metrology Organization (RMO) supplementary comparison of liquid in glass thermometer (AFRIMETS.T-S5) was carried out by the National Metrology Institute of South Africa (NMISA), Zimbabwe Scientific & Industrial Research & Development Centre—National Metrology Institute (SIRDC-NMI), Zambia Bureau of Standards (ZABS), Botswana Bureau of Standards (BOBS), Namibian Standards Institute (NSI), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between January and September 2016. The temperature range of the inter comparison is -35 °C to 250 °C. The results of this comparison are reported here, along with descriptions of the Artefacts used. This report also presents the uncertainty budget of each participant. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Key comparison BIPM.RI(I)-K5 of the air kerma standards of the ININ, Mexico and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D. T.; Alvarez Romero, J. T.; De la Cruz Hernández, D.; Cabrera Vertti, M. R.; Tovar-Muñoz, V. M.

    2015-01-01

    A direct comparison of the standards for air kerma of the Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in February 2015. The comparison result, evaluated as a ratio of the ININ and the BIPM standards for air kerma, is 1.0048 with a combined standard uncertainty of 2.0 × 10-3. The results are analysed and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. A comparison of subgroup analyses in grant applications and publications.

    PubMed

    Boonacker, Chantal W B; Hoes, Arno W; van Liere-Visser, Karen; Schilder, Anne G M; Rovers, Maroeska M

    2011-07-15

    In this paper, the authors compare subgroup analyses as outlined in grant applications and their related publications. Grants awarded by the Netherlands Organization for Health Research and Development (ZonMw) from 2001 onward that were finalized before March 1, 2010, were studied. Of the 79 grant proposals, 50 (63%) were intervention studies, 18 (23%) were diagnostic studies, and 6 (8%) were prognostic studies. Subgroups were mentioned in 49 (62%) grant applications and in 53 (67%) publications. In 20 of the 79 projects (25%), the publications were completely in agreement with the grant proposal; that is, subgroups that were prespecified in the grant proposal were reported and no new subgroup analyses were introduced in the publications. Of the 149 prespecified subgroups, 46 (31%) were reported in the final report or scientific publications, and 143 of the 189 (76%) reported subgroups were based on post-hoc findings. For 77% of the subgroup analyses in the publications, there was no mention of whether these were prespecified or post hoc. Justification for subgroup analysis and methods to study subgroups were rarely reported. The authors conclude that there is a large discrepancy between grant applications and final publications regarding subgroup analyses. Both nonreporting prespecified subgroup analyses and reporting post-hoc subgroup analyses are common. More guidance is clearly needed.

  7. KEY COMPARISON: Final report on Key Comparison APMP.SIM.M.P-K1c: Bilateral comparison between NIST (USA) and NPLI (India) in the pneumatic pressure region 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Driver, R. Gregory; Olson, Douglas A.; Dilawar, Nita; Bandyopadhyay, A. K.

    2007-01-01

    We report the results of a bilateral comparison of pressure measurement between NIST and NPLI using a piston gauge transfer standard (TS), designated as NPLI-4, over the range of nominal applied pressure 0.4 MPa to 4.0 MPa. This TS was cross-floated against the laboratory secondary standard designated as PG13 at NIST, USA and against NPLI-8 at NPLI, India. The nominal pressure points of the bilateral comparison were (0.4, 0.8, 1.2, 1.6, 2.0, 2.4, 2.8, 3.2, 3.6 and 4.0) MPa, respectively. The comparison was performed in both the institutes in identical pressure cycles in increasing pressures. The comparison data were analysed in terms of the effective area [Ap (mm2)] as a function pressure [p (MPa)] of the TS at the above-mentioned pressures. We have also estimated the zero-pressure effective area [A0 (mm2)] and the pressure distortion coefficient [λ (MPa-1)] of the transfer standard. The consistency of the results at every pressure in the range indicates that the laboratory standards used in this comparison are compatible, uniform and can be considered traceable to each other. Finally, the degree of equivalence between NPLI and NIST is 11.4 × 10-6 or better, which is always less than the relative standard uncertainty of the difference (33.6 × 10-6). Main text. To reach the main text of this Paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. Key comparison BIPM.RI(I)-K5 of the air-kerma standards of the SMU, Slovakia and the BIPM in 137Cs gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    The first direct comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 137Cs radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0051 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SMU, Slovakia and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Durný, N.

    2018-01-01

    A key comparison of the standards for air kerma of the Slovak Institute of Metrology (SMU), Slovakia and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in June 2017. The comparison result, evaluated as a ratio of the SMU and the BIPM standards for air kerma, is 1.0042 with a combined standard uncertainty of 2.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2 parts in 104. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the MKEH, Hungary and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Machula, G.

    2018-01-01

    A comparison of the standards for air kerma of the Hungarian Trade Licensing Office (MKEH), Hungary and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in March 2016. The comparison result, evaluated as a ratio of the MKEH and the BIPM standards for air kerma, is 1.0047 with a combined standard uncertainty of 1.9 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 2.6 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. SUPPLEMENTARY COMPARISON: APMP.PR-S1 comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Xu, Gan; Huang, Xuebo; Liu, Yuanjie

    2007-01-01

    APMP.PR-S1, a supplementary comparison of irradiance responsivity of UVA detectors, was carried out among seven national metrology institutes piloted by SPRING Singapore from 2003 to 2005. Two quantities, the narrow band UV (365 nm ± 5 nm) irradiance responsivity and the broad band UVA (315 nm-400 nm) irradiance responsivity of the transfer detectors, have been compared. Commercial UV source (medium pressure mercury short arc lamp) and UVA detectors were used as transfer standards in the comparison. Measurement results from participants were reported and their uncertainties associated with the comparison were analysed in this report. The method of weighted mean with cut-off was used to calculate the comparison reference values. The results from most participating labs lie within ±5% against the comparison reference values with a few exceptions. The degree of agreement of the comparison depends not only on the base scales of spectral responsivity and spectral irradiance of a laboratory, but also equally importantly on the method used for the measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. The Effectiveness of the Use of Programed Analyses of Musical Works on Students' Perception of Form. Final Report.

    ERIC Educational Resources Information Center

    Nelson, Carl B.

    Linearly programed materials used with musical references on magnetic tapes were compared to conventional listening materials used outside the classroom and to assignments for a college music course. The point of the comparison was to ascertain whether or not the programed materials significantly improved students' aural perception of the…

  13. Reaching Year 12 in Victoria, Australia: Student and School Influences

    ERIC Educational Resources Information Center

    Marks, Gary

    2014-01-01

    This paper examines student and school influences on reaching Year 12, the final year of schooling in Victoria, Australia. It analyses data from the population of students who were in Year 9 in 2008. Male, English-speaking background, government school, and especially Indigenous students were less likely to reach Year 12 than comparison groups.…

  14. Comparison of Anticipation and Study-Test Procedures of Paired-Associate Learning by Children. Final Report.

    ERIC Educational Resources Information Center

    Cole, Lawrence E.

    The study paired-associate (PA) learning via the anticipation (ANT) and study-test (ST) procedures across second, third, fourth and fifth grades. Specifically, age differences in the rate of learning and examining PA learning according to the stage analyses were examined. Retention was also of interest: however, a ceiling effect negated the…

  15. Social comparison and perceived breach of psychological contract: their effects on burnout in a multigroup analysis.

    PubMed

    Cantisano, Gabriela Topa; Domínguez, J Francisco Morales; García, J Luis Caeiro

    2007-05-01

    This study focuses on the mediator role of social comparison in the relationship between perceived breach of psychological contract and burnout. A previous model showing the hypothesized effects of perceived breach on burnout, both direct and mediated, is proposed. The final model reached an optimal fit to the data and was confirmed through multigroup analysis using a sample of Spanish teachers (N = 401) belonging to preprimary, primary, and secondary schools. Multigroup analyses showed that the model fit all groups adequately.

  16. Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D.; Cardoso, J.

    2018-01-01

    A comparison of the standards for air kerma of the Instituto Superior Técnico, Laboratório de Proteção e Segurança Radiológica (IST-LPSR), Portugal and of the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation beam of the BIPM in December 2015. The comparison result, evaluated as a ratio of the IST-LPSR and the BIPM standards for air kerma, is 1.0026 with a combined standard uncertainty of 1.7 × 10-3. The results for an indirect comparison made at the same time are consistent with the direct results at the level of 1.1 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Report on AFRIMETS supplementary comparison: platinum resistance thermometer and digital thermometer calibrations against ITS-90 over the range -50 °C to 450 °C (AFRIMETS.T-S1)

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans; Abdelaziz, Yasser; Tesfaye, Fitsum; Egadwa, Wilson; Norranim, Uthai; Rwashana, Simon; Kagoma, Alphonce; Ziagi, Adam; Kwong, Christian Ng Ha; Madeleine, Gilbert

    2017-01-01

    A Regional Metrology Organization (RMO) supplementary comparison of platinum resistance thermometer and digital thermometer (AFRIMETS.T-S1) was carried out by the National Metrology Institute of South Africa (NMISA), National Institute for Standards Egypt (NIS), National Metrology Institute of Ethiopia (NMIE), Kenya Bureau of Standards (KEBS), National Institute of Metrology Thailand (NIMT), Uganda National Bureau of Standards (UNBS), Tanzania Bureau of Standards (TBS), Mauritius Standards Bureau (MSB) and Seychelles Bureau of Standards (SBS) between March 2008 and October 2010. The temperature range of the inter comparison is -50 °C to 450 °C. The results of this comparison are reported here, along with descriptions of the Artefacts and devices used during measurement. This report also presents the uncertainty budget. The results are analysed and normalized error (En) values are reported. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    NASA Astrophysics Data System (ADS)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Application of CFD to a generic hypersonic flight research study

    NASA Technical Reports Server (NTRS)

    Green, Michael J.; Lawrence, Scott L.; Dilley, Arthur D.; Hawkins, Richard W.; Walker, Mary M.; Oberkampf, William L.

    1993-01-01

    Computational analyses have been performed for the initial assessment of flight research vehicle concepts that satisfy requirements for potential hypersonic experiments. Results were obtained from independent analyses at NASA Ames, NASA Langley, and Sandia National Labs, using sophisticated time-dependent Navier-Stokes and parabolized Navier-Stokes methods. Careful study of a common problem consisting of hypersonic flow past a slightly blunted conical forebody was undertaken to estimate the level of uncertainty in the computed results, and to assess the capabilities of current computational methods for predicting boundary-layer transition onset. Results of this study in terms of surface pressure and heat transfer comparisons, as well as comparisons of boundary-layer edge quantities and flow-field profiles are presented here. Sensitivities to grid and gas model are discussed. Finally, representative results are presented relating to the use of Computational Fluid Dynamics in the vehicle design and the integration/support of potential experiments.

  20. Living network meta-analysis compared with pairwise meta-analysis in comparative effectiveness research: empirical study.

    PubMed

    Nikolakopoulou, Adriani; Mavridis, Dimitris; Furukawa, Toshi A; Cipriani, Andrea; Tricco, Andrea C; Straus, Sharon E; Siontis, George C M; Egger, Matthias; Salanti, Georgia

    2018-02-28

    To examine whether the continuous updating of networks of prospectively planned randomised controlled trials (RCTs) ("living" network meta-analysis) provides strong evidence against the null hypothesis in comparative effectiveness of medical interventions earlier than the updating of conventional, pairwise meta-analysis. Empirical study of the accumulating evidence about the comparative effectiveness of clinical interventions. Database of network meta-analyses of RCTs identified through searches of Medline, Embase, and the Cochrane Database of Systematic Reviews until 14 April 2015. Network meta-analyses published after January 2012 that compared at least five treatments and included at least 20 RCTs. Clinical experts were asked to identify in each network the treatment comparison of greatest clinical interest. Comparisons were excluded for which direct and indirect evidence disagreed, based on side, or node, splitting test (P<0.10). Cumulative pairwise and network meta-analyses were performed for each selected comparison. Monitoring boundaries of statistical significance were constructed and the evidence against the null hypothesis was considered to be strong when the monitoring boundaries were crossed. A significance level was defined as α=5%, power of 90% (β=10%), and an anticipated treatment effect to detect equal to the final estimate from the network meta-analysis. The frequency and time to strong evidence was compared against the null hypothesis between pairwise and network meta-analyses. 49 comparisons of interest from 44 networks were included; most (n=39, 80%) were between active drugs, mainly from the specialties of cardiology, endocrinology, psychiatry, and rheumatology. 29 comparisons were informed by both direct and indirect evidence (59%), 13 by indirect evidence (27%), and 7 by direct evidence (14%). Both network and pairwise meta-analysis provided strong evidence against the null hypothesis for seven comparisons, but for an additional 10 comparisons only network meta-analysis provided strong evidence against the null hypothesis (P=0.002). The median time to strong evidence against the null hypothesis was 19 years with living network meta-analysis and 23 years with living pairwise meta-analysis (hazard ratio 2.78, 95% confidence interval 1.00 to 7.72, P=0.05). Studies directly comparing the treatments of interest continued to be published for eight comparisons after strong evidence had become evident in network meta-analysis. In comparative effectiveness research, prospectively planned living network meta-analyses produced strong evidence against the null hypothesis more often and earlier than conventional, pairwise meta-analyses. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Living network meta-analysis compared with pairwise meta-analysis in comparative effectiveness research: empirical study

    PubMed Central

    Nikolakopoulou, Adriani; Mavridis, Dimitris; Furukawa, Toshi A; Cipriani, Andrea; Tricco, Andrea C; Straus, Sharon E; Siontis, George C M; Egger, Matthias

    2018-01-01

    Abstract Objective To examine whether the continuous updating of networks of prospectively planned randomised controlled trials (RCTs) (“living” network meta-analysis) provides strong evidence against the null hypothesis in comparative effectiveness of medical interventions earlier than the updating of conventional, pairwise meta-analysis. Design Empirical study of the accumulating evidence about the comparative effectiveness of clinical interventions. Data sources Database of network meta-analyses of RCTs identified through searches of Medline, Embase, and the Cochrane Database of Systematic Reviews until 14 April 2015. Eligibility criteria for study selection Network meta-analyses published after January 2012 that compared at least five treatments and included at least 20 RCTs. Clinical experts were asked to identify in each network the treatment comparison of greatest clinical interest. Comparisons were excluded for which direct and indirect evidence disagreed, based on side, or node, splitting test (P<0.10). Outcomes and analysis Cumulative pairwise and network meta-analyses were performed for each selected comparison. Monitoring boundaries of statistical significance were constructed and the evidence against the null hypothesis was considered to be strong when the monitoring boundaries were crossed. A significance level was defined as α=5%, power of 90% (β=10%), and an anticipated treatment effect to detect equal to the final estimate from the network meta-analysis. The frequency and time to strong evidence was compared against the null hypothesis between pairwise and network meta-analyses. Results 49 comparisons of interest from 44 networks were included; most (n=39, 80%) were between active drugs, mainly from the specialties of cardiology, endocrinology, psychiatry, and rheumatology. 29 comparisons were informed by both direct and indirect evidence (59%), 13 by indirect evidence (27%), and 7 by direct evidence (14%). Both network and pairwise meta-analysis provided strong evidence against the null hypothesis for seven comparisons, but for an additional 10 comparisons only network meta-analysis provided strong evidence against the null hypothesis (P=0.002). The median time to strong evidence against the null hypothesis was 19 years with living network meta-analysis and 23 years with living pairwise meta-analysis (hazard ratio 2.78, 95% confidence interval 1.00 to 7.72, P=0.05). Studies directly comparing the treatments of interest continued to be published for eight comparisons after strong evidence had become evident in network meta-analysis. Conclusions In comparative effectiveness research, prospectively planned living network meta-analyses produced strong evidence against the null hypothesis more often and earlier than conventional, pairwise meta-analyses. PMID:29490922

  2. Moulding techniques in lipstick manufacture: a comparative evaluation.

    PubMed

    Dweck, A C; Burnham, C A

    1980-06-01

    Synopsis This paper examines two methods of lipstick bulk manufacture: one via a direct method and the other via stock concentrates. The paper continues with a comparison of two manufactured bulks moulded in three different ways - first by split moulding, secondly by Rotamoulding, and finally by Ejectoret moulding. Full consideration is paid to time, labour and cost standards of each approach and the resultant moulding examined using some novel physical testing methods. The results of these tests are statistically analysed. Finally, on the basis of the gathered data and photomicrographical work a theoretical lipstick structure is proposed by which the results may be explained.

  3. Behavioral genetics and taste

    PubMed Central

    Boughter, John D; Bachmanov, Alexander A

    2007-01-01

    This review focuses on behavioral genetic studies of sweet, umami, bitter and salt taste responses in mammals. Studies involving mouse inbred strain comparisons and genetic analyses, and their impact on elucidation of taste receptors and transduction mechanisms are discussed. Finally, the effect of genetic variation in taste responsiveness on complex traits such as drug intake is considered. Recent advances in development of genomic resources make behavioral genetics a powerful approach for understanding mechanisms of taste. PMID:17903279

  4. Publishing interim results of randomised clinical trials in peer-reviewed journals.

    PubMed

    Counsell, Nicholas; Biri, Despina; Fraczek, Joanna; Hackshaw, Allan

    2017-02-01

    Interim analyses of randomised controlled trials are sometimes published before the final results are available. In several cases, the treatment effects were noticeably different after patient recruitment and follow-up completed. We therefore conducted a literature review of peer-reviewed journals to compare the reported treatment effects between interim and final publications and to examine the magnitude of the difference. We performed an electronic search of MEDLINE from 1990 to 2014 (keywords: 'clinical trial' OR 'clinical study' AND 'random*' AND 'interim' OR 'preliminary'), and we manually identified the corresponding final publication. Where the electronic search produced a final report in which the abstract cited interim results, we found the interim publication. We also manually searched every randomised controlled trial in eight journals, covering a range of impact factors and general medical and specialist publications (1996-2014). All paired articles were checked to ensure that the same comparison between interventions was available in both. In all, 63 studies are included in our review, and the same quantitative comparison was available in 58 of these. The final treatment effects were smaller than the interim ones in 39 (67%) trials and the same size or larger in 19 (33%). There was a marked reduction, defined as a ≥20% decrease in the size of the treatment effect from interim to final analysis, in 11 (19%) trials compared to a marked increase in 3 (5%), p = 0.057. The magnitude of percentage change was larger in trials where commercial support was reported, and increased as the proportion of final events at the interim report decreased in trials where commercial support was reported (interaction p = 0.023). There was no evidence of a difference between trials that stopped recruitment at the interim analysis where this was reported as being pre-specified versus those that were not pre-specified (interaction p = 0.87). Published interim trial results were more likely to be associated with larger treatment effects than those based on the final report. Publishing interim results should be discouraged, in order to have reliable estimates of treatment effects for clinical decision-making, regulatory authority reviews and health economic analyses. Our work should be expanded to include conference publications and manual searches of additional journal publications.

  5. Finite element elastic-plastic-creep and cyclic life analysis of a cowl lip

    NASA Technical Reports Server (NTRS)

    Arya, Vinod K.; Melis, Matthew E.; Halford, Gary R.

    1990-01-01

    Results are presented of elastic, elastic-plastic, and elastic-plastic-creep analyses of a test-rig component of an actively cooled cowl lip. A cowl lip is part of the leading edge of an engine inlet of proposed hypersonic aircraft and is subject to severe thermal loadings and gradients during flight. Values of stresses calculated by elastic analysis are well above the yield strength of the cowl lip material. Such values are highly unrealistic, and thus elastic stress analyses are inappropriate. The inelastic (elastic-plastic and elastic-plastic-creep) analyses produce more reasonable and acceptable stress and strain distributions in the component. Finally, using the results from these analyses, predictions are made for the cyclic crack initiation life of a cowl lip. A comparison of predicted cyclic lives shows the cyclic life prediction from the elastic-plastic-creep analysis to be the lowest and, hence, most realistic.

  6. Ocean data assimilation using optimal interpolation with a quasi-geostrophic model

    NASA Technical Reports Server (NTRS)

    Rienecker, Michele M.; Miller, Robert N.

    1991-01-01

    A quasi-geostrophic (QG) stream function is analyzed by optimal interpolation (OI) over a 59-day period in a 150-km-square domain off northern California. Hydrographic observations acquired over five surveys were assimilated into a QG open boundary ocean model. Assimilation experiments were conducted separately for individual surveys to investigate the sensitivity of the OI analyses to parameters defining the decorrelation scale of an assumed error covariance function. The analyses were intercompared through dynamical hindcasts between surveys. The best hindcast was obtained using the smooth analyses produced with assumed error decorrelation scales identical to those of the observed stream function. The rms difference between the hindcast stream function and the final analysis was only 23 percent of the observation standard deviation. The two sets of OI analyses were temporally smoother than the fields from statistical objective analysis and in good agreement with the only independent data available for comparison.

  7. Overview of MSFC AMSD Integrated Modeling and Analysis

    NASA Technical Reports Server (NTRS)

    Cummings, Ramona; Russell, Kevin (Technical Monitor)

    2002-01-01

    Structural, thermal, dynamic, and optical models of the NGST AMSD mirror assemblies are being finalized and integrated for predicting cryogenic vacuum test performance of the developing designs. Analyzers in use by the MSFC Modeling and Analysis Team are identified, with overview of approach to integrate simulated effects. Guidelines to verify the individual models and calibration cases for comparison with the vendors' analyses are presented. In addition, baseline and proposed additional scenarios for the cryogenic vacuum testing are briefly described.

  8. Flexible Substrates Comparison for Pled Technology

    NASA Astrophysics Data System (ADS)

    Nenna, G.; Miscioscia, R.; Tassini, P.; Minarini, C.; Vacca, P.; Valentino, O.

    2008-08-01

    Flexible substrate displays are critical to organic electronics, e-paper's and e-ink's development. Many different types of materials are under investigation, including glass, polymer films and metallic foils. In this work we report a comparison study of polymer films as flexible substrates for polymer light emitting diodes (PLEDs) technology. The selected polymer substrates are two thermoplastic semi-crystalline polymers (PET and PEN) and a high Tg material that cannot be melt processed (PAR). Firstly, the chosen films were characterized in morphology and optical properties with the aim to confirm their suitability for optoelectronic applications. Transmittance was analysed by UV-Vis spectrophotometry and roughness by a surface profilometer. Finally, the surface energy of substrates (untreated and after UV-ozone treatment) was estimated by contact angle measurements in order to evaluate their wettability for active materials deposition.

  9. NASTRAN benefits analysis. Volume 2: Final technical report

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Baseline data are considered for comparisons of the costs and benefits of the NASA structural analysis program and to determine impacts and benefits to current users. To develop this information, questionnaires were mailed to users. Personal and telephone interviews were made to solicit further information. The questions in the questionnaire and in the interview were related to benefits derived from the programs, areas of needed improvement, and applicable usage comments. The collected information was compiled and analyzed. Methodology, analyses, and results are presented. The information is applicable to issues preceding NASTRAN Level 15.

  10. Influence of a revision course and the gender of examiners on the grades of the final ENT exam – a retrospective review of 3961 exams

    PubMed Central

    Grasl, Matthäus C.; Seemann, Rudolf; Hanisch, Michael; Heiduschka, Gregor; Kremser, Karl; Thurnher, Dietmar

    2015-01-01

    Revision courses should repeat already acquired knowledge and skills and mostly provide a basis for passing the following exam. Aim: The aim of the study is to investigate the influence of a previously attended revision course on the grades achieved in a final exam (Ear, Nose and Throat Diseases). Additionally we ask the question whether the gender of the examiners plays a role concerning the marks or not. Methods: 3961 exams at the Department of Ear, Nose and Throat (ENT) Diseases in Vienna were investigated, 725 with revision course (experimental group) and 3236 without previous revision course (comparison group). The revision courses were performed in a standardized way concerning form and content, interactive and case based. Both groups were examined uniform in regard to topics and time duration. 16 male and 6 female examiners were involved. The grading followed a five–level scale. The examination marks were calculated in the arithmetic mean and median value for the entire sample, gender dependence was calculated according to the Wilcoxon-Mann-Whitney-Test. The inferential statistics included single- and multiple factorial analyses of variance as well as uni- and multivariate regression models. Results: The experimental group achieved a grade average of 2.54 compared with 2.46 for the comparison group. Splitting up into male and female examiners, an average of 2.54 and 2.58 resp. for the experimental group and 2.44 and 2.61 resp. for the comparison group resulted. Female examiner marked significantly lower grades in comparison to their male colleagues (P= 0.001926). Conclusions: The ENT revision course did not improve the grade averages of the final ENT exam. Female examiners grade stricter than male examiners. There was no difference concerning grades 4 (pass) and 5 (fail) but female examiners grade less with mark 1. PMID:26483851

  11. SUPPLEMENTARY COMPARISON: Final report on APMP.PR-S1.1: Bilateral comparison of irradiance responsivity of UVA detectors

    NASA Astrophysics Data System (ADS)

    Huang, Xuebo

    2009-01-01

    In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. A Comparison of Simplified Two-dimensional Flow Models Exemplified by Water Flow in a Cavern

    NASA Astrophysics Data System (ADS)

    Prybytak, Dzmitry; Zima, Piotr

    2017-12-01

    The paper shows the results of a comparison of simplified models describing a two-dimensional water flow in the example of a water flow through a straight channel sector with a cavern. The following models were tested: the two-dimensional potential flow model, the Stokes model and the Navier-Stokes model. In order to solve the first two, the boundary element method was employed, whereas to solve the Navier-Stokes equations, the open-source code library OpenFOAM was applied. The results of numerical solutions were compared with the results of measurements carried out on a test stand in a hydraulic laboratory. The measurements were taken with an ADV probe (Acoustic Doppler Velocimeter). Finally, differences between the results obtained from the mathematical models and the results of laboratory measurements were analysed.

  13. Response to "Comparison and Evaluation of Clustering Algorithms for Tandem Mass Spectra".

    PubMed

    Griss, Johannes; Perez-Riverol, Yasset; The, Matthew; Käll, Lukas; Vizcaíno, Juan Antonio

    2018-05-04

    In the recent benchmarking article entitled "Comparison and Evaluation of Clustering Algorithms for Tandem Mass Spectra", Rieder et al. compared several different approaches to cluster MS/MS spectra. While we certainly recognize the value of the manuscript, here, we report some shortcomings detected in the original analyses. For most analyses, the authors clustered only single MS/MS runs. In one of the reported analyses, three MS/MS runs were processed together, which already led to computational performance issues in many of the tested approaches. This fact highlights the difficulties of using many of the tested algorithms on the nowadays produced average proteomics data sets. Second, the authors only processed identified spectra when merging MS runs. Thereby, all unidentified spectra that are of lower quality were already removed from the data set and could not influence the clustering results. Next, we found that the authors did not analyze the effect of chimeric spectra on the clustering results. In our analysis, we found that 3% of the spectra in the used data sets were chimeric, and this had marked effects on the behavior of the different clustering algorithms tested. Finally, the authors' choice to evaluate the MS-Cluster and spectra-cluster algorithms using a precursor tolerance of 5 Da for high-resolution Orbitrap data only was, in our opinion, not adequate to assess the performance of MS/MS clustering approaches.

  14. Final report of the regional key comparison EURAMET.M.G-K1: European Comparison of Absolute Gravimeters ECAG-2011

    NASA Astrophysics Data System (ADS)

    Francis, Olivier; Klein, Gilbert; Baumann, Henri; Dando, Nicolas; Tracey, Ray; Ullrich, Christian; Castelein, Stefaan; Hua, Hu; Kang, Wu; Chongyang, Shen; Songbo, Xuan; Hongbo, Tan; Zhengyuan, Li; Pálinkás, Vojtech; Kostelecký, Jakub; Mäkinen, Jaakko; Näränen, Jyri; Merlet, Sébastien; Farah, Tristan; Guerlin, Christine; Pereira Dos Santos, Franck; Le Moigne, Nicolas; Champollion, Cédric; Deville, Sabrina; Timmen, Ludger; Falk, Reinhard; Wilmes, Herbert; Iacovone, Domenico; Baccaro, Francesco; Germak, Alessandro; Biolcati, Emanuele; Krynski, Jan; Sekowski, Marcin; Olszak, Tomasz; Pachuta, Andrzej; Agren, Jonas; Engfeldt, Andreas; Reudink, René; Inacio, Pedro; McLaughlin, Daniel; Shannon, Geoff; Eckl, Marc; Wilkins, Tim; van Westrum, Derek; Billson, Ryan

    2012-01-01

    During November 2011 a EURAMET key comparison of absolute gravimeters was organized in the Underground Laboratory for Geodynamics in Walferdange, Luxemburg. The comparison assembled 22 participants coming from 16 countries and four different continents. The comparison was divided into two parts: a key comparison that included six National Metrology Institutes or Designated Institutes, and a pilot study including all participants. The global result given by the pilot study confirms that all instruments are absolutely coherent with each other. The results obtained in the key comparison confirm a good agreement between the NMI instruments. Finally, a link to ICAG-2009 shows also that the NMI gravimeters are stable in time. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Voxel-Wise Comparisons of the Morphology of Diffusion Tensors Across Groups of Experimental Subjects

    PubMed Central

    Bansal, Ravi; Staib, Lawrence H.; Plessen, Kerstin J.; Xu, Dongrong; Royal, Jason; Peterson, Bradley S.

    2007-01-01

    Water molecules in the brain diffuse preferentially along the fiber tracts within white matter, which form the anatomical connections across spatially distant brain regions. A diffusion tensor (DT) is a probabilistic ellipsoid composed of 3 orthogonal vectors, each having a direction and an associated scalar magnitude, that represent the probability of water molecules diffusing in each of those directions. The 3D morphologies of DTs can be compared across groups of subjects to reveal disruptions in structural organization and neuroanatomical connectivity of the brains of persons with various neuropsychiatric illnesses. Comparisons of tensor morphology across groups have typically been performed on scalar measures of diffusivity, such as Fractional Anisotropy (FA), rather than directly on the complex 3D morphologies of DTs. Scalar measures, however, are related in nonlinear ways to the eigenvalues and eigenvectors that create the 3D morphologies of DTs. We present a mathematical framework that permits the direct comparison across groups of mean eigenvalues and eigenvectors of individual DTs. We show that group-mean eigenvalues and eigenvectors are multivariate Gaussian distributed, and we use the Delta method to compute their approximate covariance matrices. Our results show that the theoretically computed Mean Tensor (MT) eigenvectors and eigenvalues match well with their respective true values. Furthermore, a comparison of synthetically generated groups of DTs highlights the limitations of using FA to detect group differences. Finally, analyses of in vivo DT data using our method reveal significant between-group differences in diffusivity along fiber tracts within white matter, whereas analyses based on FA values failed to detect some of these differences. PMID:18006284

  16. Regional health accounts for Pakistan--expenditure disparities on provincial and district level.

    PubMed

    Lorenz, Christian; Khalid, Muhammad

    2011-05-01

    Since May 2009 the first National Health Accounts (NHA) for Pakistan have been finalised and published by Federal Bureau of Statistics (FBS) in cooperation with German Technical Cooperation (GTZ). This paper goes one step ahead of the report and analyses in more detail the regional differences in health expenditure structures in Pakistan. The further analyses can be divided into four parts: health expenditures in provinces (Provincial Health Accounts, PHA), Punjab provincial and district governments health expenditures and its comparison with ADB figures, all districts of Pakistan and comparison between total district government and provincial government expenditure for each province; the latter calculation is applied as indication for the degree of fiscal autonomy of the districts in each province. Consequently, first the provincial health expenditures by Financial Agents is analysed and compared between the provinces which leads to very heterogeneous results (section 2); the per capita health expenditures differ from 16 to 23 USD. Secondly, NHA results on Punjab district government are compared with available ADB results and differences in methods as possible reasons for different results are presented (section 3). Third, district data of all district governments in all four Pakistani provinces are analysed on the level of detailed function codes in section 4; the aim is to discover regional differences between districts of the same as well as of different provinces. Fourth, in section 5 the degree of fiscal autonomy on health of the districts in each province is analysed; therefore the ordinance description is reviewed and total district government with total provincial government expenditures are compared per province. Finally recommendations for future rounds of NHA in Pakistan are given regarding formats and necessities of detailed health expenditure data collection to ensure evidence based decision making not only on federal, but also on provincial and district level.

  17. Use of TRMM Rainfall Information in Improving Long-Term, Satellite-Based Global Precipitation Analyses

    NASA Technical Reports Server (NTRS)

    Starr, David OC. (Technical Monitor); Adler, Robert F.; Huffman, George; Curtis, Scott; Bolvin, David; Nelkin, Eric

    2002-01-01

    The TRMM rainfall products are inter-compared among themselves and to the 23 year, monthly, globally complete precipitation analysis of the World Climate Research Program's (WCRP/ GEWEX) Global Precipitation Climatology Project (GPCP). Ways in which the TRMM-based estimates can be used to improve the long-term data set are described. These include improvement of the passive microwave algorithm that is applied to the 15 year SSM/I record and calibration or adjustment of the current GPCP fields utilizing the 4-5 year overlap of TRMM and GPCP. A comparison of the GPCP monthly surface precipitation fields and the TRMM-based multi-satellite analyses indicates that the two are similar, but have significant differences that relate to the different input data sets. Although on a zonal average basis over the ocean the two analyses are similar in the deep Tropics, there are subtle differences between the eastern and western Pacific Ocean in the relative magnitudes. In mid-latitudes the GPCP has somewhat larger mean precipitation than TRMM. Statistical comparisons of TRMM and GPCP monthly fields are carried out in terms of histogram matching for both ocean and land regions and for small areas to diagnose differences. These comparisons form the basis for a TRMM calibration of the GPCP fields using matched histograms over regional areas as a function of season. Although final application of this procedure will likely await the Version 6 of the TRMM products, tests using Version 5 are shown that provide a TRMM-calibrated GPCP version that will produce an improved climatology and a more accurate month-to-month precipitation analysis for the last 20 years.

  18. Continuous chelation irrigation improves the adhesion of epoxy resin-based root canal sealer to root dentine.

    PubMed

    Neelakantan, P; Varughese, A A; Sharma, S; Subbarao, C V; Zehnder, M; De-Deus, G

    2012-12-01

    To test the impact of continuous chelation by NaOCl+ etidronic acid (HEBP) during instrumentation, and a final rinse of EDTA or NaOCl + HEBP on the dentine bond strength of an epoxy resin sealer (AH Plus). Single-rooted teeth (n = 100) were divided into five groups (n = 20) based on the irrigation protocol and their root canals instrumented using a rotary Ni-Ti system: 2.5% NaOCl during instrumentation followed by bi-distilled water (G1) or 17% EDTA (G2) as final rinse; 1 : 1 mixture of 5% NaOCl and 18% HEBP during instrumentation, and the same mixture (G3), 17% EDTA (G4) or bi-distilled water (G5) as final rinse. Canals were filled with AH Plus. Roots were sectioned, and push-out tests were performed in coronal, middle and apical root thirds. Results were analysed using analysis of variance (anova) and Bonferroni test for multiple comparisons. The alpha-type error was set at 0.05 for all the analyses. Push-out bond strength was highest in coronal and lowest in apical root thirds (P < 0.05). Groups that used NaOCl + HEBP irrigation during instrumentation had significantly higher bond strengths than groups following the NaOCl-EDTA irrigation in all root thirds (P < 0.05). The use of a strong chelator as final flush further increased bond strengths (G4, P < 0.05). The continuous chelation irrigation protocol optimizes the bond strength of an epoxy resin sealer to dentine. © 2012 International Endodontic Journal.

  19. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 5, Uncertainty and sensitivity analyses of gas and brine migration for undisturbed performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-08-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to migration of gas and brine from the undisturbed repository. Additional information about the 1992 PA is provided in other volumes. Volume 1 containsmore » an overview of WIPP PA and results of a preliminary comparison with 40 CFR 191, Subpart B. Volume 2 describes the technical basis for the performance assessment, including descriptions of the linked computational models used in the Monte Carlo analyses. Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses with respect to the EPA`s Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Finally, guidance derived from the entire 1992 PA is presented in Volume 6. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect gas and brine migration from the undisturbed repository are: initial liquid saturation in the waste, anhydrite permeability, biodegradation-reaction stoichiometry, gas-generation rates for both corrosion and biodegradation under inundated conditions, and the permeability of the long-term shaft seal.« less

  20. Understanding arid environments using fossil rodent middens

    USGS Publications Warehouse

    Pearson, S.; Betancourt, J.L.

    2002-01-01

    American rodent middens have made a more dramatic contribution to understanding past environments and the development of ecological theory than Australian rodent middens. This relates to differences in the natural environment, the landscape histories, the scale and scientific approaches of the researchers. The comparison demonstrates: the power of synoptic perspectives; the value of thorough macrofossil identification in midden analysis and its potential advance in Australia where pollen has dominated analyses, the value of herbaria and reference collections; the potential of environmental databases; the importance of scientific history and 'critical research mass' and; finally, the opportunistic nature of palaeoecological research. ?? 2002 Elsevier Science Ltd.

  1. Analysis and correlation of the test data from an advanced technology rotor system

    NASA Technical Reports Server (NTRS)

    Jepson, D.; Moffitt, R.; Hilzinger, K.; Bissell, J.

    1983-01-01

    Comparisons were made of the performance and blade vibratory loads characteristics for an advanced rotor system as predicted by analysis and as measured in a 1/5 scale model wind tunnel test, a full scale model wind tunnel test and flight test. The accuracy with which the various tools available at the various stages in the design/development process (analysis, model test etc.) could predict final characteristics as measured on the aircraft was determined. The accuracy of the analyses in predicting the effects of systematic tip planform variations investigated in the full scale wind tunnel test was evaluated.

  2. Comparing composts formed by different technological processing

    NASA Astrophysics Data System (ADS)

    Lyckova, B.; Mudrunka, J.; Kucerova, R.; Glogarova, V.

    2017-10-01

    The presented article compares quality of composts which were formed by different technological processes. The subject to comparison was a compost which was created in a closed fermenter where ideal conditions for decomposition and organic substances conversion were ensured, with compost which was produced in an open box of community composting. The created composts were analysed to determine whether it is more important for the final compost to comply with the composting conditions or better sorting of raw materials needed for compost production. The results of the carried out experiments showed that quality of the resulting compost cannot be determined unequivocally.

  3. Fatigue Crack Growth in Peened Friction Stir Welds

    NASA Technical Reports Server (NTRS)

    Forth, Scott C.; Hatamleh, Omar

    2008-01-01

    Friction stir welding induces residual stresses that accelerates fatigue crack growth in the weld nugget. Shot peening over the weld had little effect on growth rate. Laser peening over the weld retarded the growth rate: Final crack growth rate was comparable to the base, un-welded material. Crack tunneling evident from residual compressive stresses. 2195-T8 fracture surfaces were highly textured. Texturing makes comparisons difficult as the material system is affecting the data as much as the processing. Material usage becoming more common in space applications requiring additional work to develop useful datasets for damage tolerance analyses.

  4. The development and validation of the Physical Appearance Comparison Scale-3 (PACS-3).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2018-05-21

    Appearance comparison processes are implicated in the development of body-image disturbance and disordered eating. The Physical Appearance Comparison Scale-Revised (PACS-R) assesses the simple frequency of appearance comparisons; however, research has suggested that other aspects of appearance comparisons (e.g., comparison direction) may moderate the association between comparisons and their negative outcomes. In the current study, the PACS-R was revised to examine aspects of comparisons with relevance to body-image and eating outcomes. Specifically, the measure was modified to examine (a) dimensions of physical appearance relevant to men and women (i.e., weight-shape, muscularity, and overall physical appearance), (b) comparisons with proximal and distal targets, (c) upward versus downward comparisons, and (d) the acute emotional impact of comparisons. The newly revised measure, labeled the PACS-3, along with existing measures of appearance comparison, body satisfaction, eating pathology, and self-esteem, was completed by 1,533 college men and women. Exploratory and confirmatory factor analyses were conducted to examine the factor structure of the PACS-3. In addition, the reliability, convergent validity, and incremental validity of the PACS-3 scores were examined. The final PACS-3 comprises 27 items and 9 subscales: Proximal: Frequency, Distal: Frequency, Muscular: Frequency, Proximal: Direction, Distal: Direction, Muscular: Direction, Proximal: Effect, Distal: Effect, and Muscular: Effect. the PACS-3 subscale scores demonstrated good reliability and convergent validity. Moreover, the PACS-3 subscales greatly improved the prediction of body satisfaction and disordered eating relative to existing measures of appearance comparison. Overall, the PACS-3 improves upon existing scales and offers a comprehensive assessment of appearance-comparison processes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobromir Panayotov; Andrew Grief; Brad J. Merrill

    'Fusion for Energy' (F4E) develops designs and implements the European Test Blanket Systems (TBS) in ITER - Helium-Cooled Lithium-Lead (HCLL) and Helium-Cooled Pebble-Bed (HCPB). Safety demonstration is an essential element for the integration of TBS in ITER and accident analyses are one of its critical segments. A systematic approach to the accident analyses had been acquired under the F4E contract on TBS safety analyses. F4E technical requirements and AMEC and INL efforts resulted in the development of a comprehensive methodology for fusion breeding blanket accident analyses. It addresses the specificity of the breeding blankets design, materials and phenomena and atmore » the same time is consistent with the one already applied to ITER accident analyses. Methodology consists of several phases. At first the reference scenarios are selected on the base of FMEA studies. In the second place elaboration of the accident analyses specifications we use phenomena identification and ranking tables to identify the requirements to be met by the code(s) and TBS models. Thus the limitations of the codes are identified and possible solutions to be built into the models are proposed. These include among others the loose coupling of different codes or code versions in order to simulate multi-fluid flows and phenomena. The code selection and issue of the accident analyses specifications conclude this second step. Furthermore the breeding blanket and ancillary systems models are built on. In this work challenges met and solutions used in the development of both MELCOR and RELAP5 codes models of HCLL and HCPB TBSs will be shared. To continue the developed models are qualified by comparison with finite elements analyses, by code to code comparison and sensitivity studies. Finally, the qualified models are used for the execution of the accident analyses of specific scenario. When possible the methodology phases will be illustrated in the paper by limited number of tables and figures. Description of each phase and its results in detail as well the methodology applications to EU HCLL and HCPB TBSs will be published in separate papers. The developed methodology is applicable to accident analyses of other TBSs to be tested in ITER and as well to DEMO breeding blankets.« less

  6. KEY COMPARISON: Final report, on-going key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII, 2007

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez Blaya, Carmen

    2009-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone mole fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. KEY COMPARISON: Final report on bilateral comparison CCEM.RF-K9.1: Thermal noise standards at 12.4 GHz, 13.5 GHz, 15 GHz and 17.5 GHz

    NASA Astrophysics Data System (ADS)

    Allal, Djamel

    2009-01-01

    A bilateral comparison subsequent to key comparison CCEM.RF-K9 was decided between VNIIFTRI and PTB. It was registered into the BIPM KCDB under the identifier CCEM.RF-K9.1. The results of this comparison were gathered by the pilot laboratory of comparison CCEM.RF-K9, the LNE, and a very good agreement was found between the two participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  8. jvenn: an interactive Venn diagram viewer.

    PubMed

    Bardou, Philippe; Mariette, Jérôme; Escudié, Frédéric; Djemiel, Christophe; Klopp, Christophe

    2014-08-29

    Venn diagrams are commonly used to display list comparison. In biology, they are widely used to show the differences between gene lists originating from different differential analyses, for instance. They thus allow the comparison between different experimental conditions or between different methods. However, when the number of input lists exceeds four, the diagram becomes difficult to read. Alternative layouts and dynamic display features can improve its use and its readability. jvenn is a new JavaScript library. It processes lists and produces Venn diagrams. It handles up to six input lists and presents results using classical or Edwards-Venn layouts. User interactions can be controlled and customized. Finally, jvenn can easily be embeded in a web page, allowing to have dynamic Venn diagrams. jvenn is an open source component for web environments helping scientists to analyze their data. The library package, which comes with full documentation and an example, is freely available at http://bioinfo.genotoul.fr/jvenn.

  9. Analysis of the Efficacy of an Intervention to Improve Parent-Adolescent Problem Solving

    PubMed Central

    Semeniuk, Yulia Yuriyivna; Brown, Roger L.; Riesch, Susan K.

    2016-01-01

    We conducted a two-group longitudinal partially nested randomized controlled trial to examine whether young adolescent youth-parent dyads participating in Mission Possible: Parents and Kids Who Listen, in contrast to a comparison group, would demonstrate improved problem solving skill. The intervention is based on the Circumplex Model and Social Problem Solving Theory. The Circumplex Model posits that families who are balanced, that is characterized by high cohesion and flexibility and open communication, function best. Social Problem Solving Theory informs the process and skills of problem solving. The Conditional Latent Growth Modeling analysis revealed no statistically significant differences in problem solving among the final sample of 127 dyads in the intervention and comparison groups. Analyses of effect sizes indicated large magnitude group effects for selected scales for youth and dyads portraying a potential for efficacy and identifying for whom the intervention may be efficacious if study limitations and lessons learned were addressed. PMID:26936844

  10. The Financial Benefits of Various Catastrophic Failure Prevention Strategies in a Wind Farm: Two market studies (UK-Spain)

    NASA Astrophysics Data System (ADS)

    Yürüşen, N. Y.; Tautz-Weinert, J.; Watson, S. J.; Melero, J. J.

    2017-11-01

    Operation of wind farms is driven by the overall aim of minimising costs while maximising energy sales. However, in certain circumstances investments are required to guarantee safe operation and survival of an asset. In this paper, we discuss the merits of various catastrophic failure prevention strategies in a Spanish wind farm. The wind farm operator was required to replace blades in two phases: temporary and final repair. We analyse the power performance of the turbine in the different states and investigate four scenarios with different timing of temporary and final repair during one year. The financial consequences of the scenarios are compared with a baseline by using a discounted cash flow analysis that considers the wholesale electricity market selling prices and interest rates. A comparison with the UK electricity market is conducted to highlight differences in the rate of return in the two countries.

  11. The Multidimensional Assessment of Interoceptive Awareness (MAIA)

    PubMed Central

    Mehling, Wolf E.; Price, Cynthia; Daubenmier, Jennifer J.; Acree, Mike; Bartmess, Elizabeth; Stewart, Anita

    2012-01-01

    This paper describes the development of a multidimensional self-report measure of interoceptive body awareness. The systematic mixed-methods process involved reviewing the current literature, specifying a multidimensional conceptual framework, evaluating prior instruments, developing items, and analyzing focus group responses to scale items by instructors and patients of body awareness-enhancing therapies. Following refinement by cognitive testing, items were field-tested in students and instructors of mind-body approaches. Final item selection was achieved by submitting the field test data to an iterative process using multiple validation methods, including exploratory cluster and confirmatory factor analyses, comparison between known groups, and correlations with established measures of related constructs. The resulting 32-item multidimensional instrument assesses eight concepts. The psychometric properties of these final scales suggest that the Multidimensional Assessment of Interoceptive Awareness (MAIA) may serve as a starting point for research and further collaborative refinement. PMID:23133619

  12. Biases and power for groups comparison on subjective health measurements.

    PubMed

    Hamel, Jean-François; Hardouin, Jean-Benoit; Le Neel, Tanguy; Kubis, Gildas; Roquelaure, Yves; Sébille, Véronique

    2012-01-01

    Subjective health measurements are increasingly used in clinical research, particularly for patient groups comparisons. Two main types of analytical strategies can be used for such data: so-called classical test theory (CTT), relying on observed scores and models coming from Item Response Theory (IRT) relying on a response model relating the items responses to a latent parameter, often called latent trait. Whether IRT or CTT would be the most appropriate method to compare two independent groups of patients on a patient reported outcomes measurement remains unknown and was investigated using simulations. For CTT-based analyses, groups comparison was performed using t-test on the scores. For IRT-based analyses, several methods were compared, according to whether the Rasch model was considered with random effects or with fixed effects, and the group effect was included as a covariate or not. Individual latent traits values were estimated using either a deterministic method or by stochastic approaches. Latent traits were then compared with a t-test. Finally, a two-steps method was performed to compare the latent trait distributions, and a Wald test was performed to test the group effect in the Rasch model including group covariates. The only unbiased IRT-based method was the group covariate Wald's test, performed on the random effects Rasch model. This model displayed the highest observed power, which was similar to the power using the score t-test. These results need to be extended to the case frequently encountered in practice where data are missing and possibly informative.

  13. KEY COMPARISON: Final report on CCPR K1-a: Spectral irradiance from 250 nm to 2500 nm

    NASA Astrophysics Data System (ADS)

    Woolliams, Emma R.; Fox, Nigel P.; Cox, Maurice G.; Harris, Peter M.; Harrison, Neil J.

    2006-01-01

    The CCPR K1-a key comparison of spectral irradiance (from 250 nm to 2500 nm) was carried out to meet the requirements of the Mutual Recognition Arrangement by 13 participating national metrology institutes (NMIs). Because of the fragile nature of the tungsten halogen lamps used as comparison artefacts, the comparison was arranged as a star comparison with three lamps per participant. NPL (United Kingdom) piloted the comparison and, by measuring all lamps, provided a link between participants' measurements. The other participants were BNM-INM (France), CENAM (Mexico), CSIRO (Australia), HUT (Finland), IFA-CSIC (Spain), MSL-IRL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NRC (Canada), PTB (Germany) and VNIIOFI (Russian Federation). Before the analysis was completed and the results known, the pilot discussed with each participant which lamp measurements should be included as representative of their comparison. As a consequence of this check, at least one measurement was excluded from one third of the lamps because of changes due to transportations. The comparison thus highlighted the difficulty regarding the availability of suitable transfer standards for the dissemination of spectral irradiance. The use of multiple lamps and multiple measurements ensured sufficient redundancy that all participants were adequately represented. In addition, during this pre-draft A phase all participants had the opportunity to review the uncertainty budgets and methods of all other participants. This new process helped to ensure that all submitted results and their associated uncertainties were evaluated in a consistent manner. The comparison was analysed using a model-based method which regarded each lamp as having a stable spectral irradiance and the measurements made by an NMI as systematically influenced by a factor that applies to all that NMI's measurements. The aim of the analysis was to estimate the systematic factor for each NMI. Across the spectral region (250 nm to 2500 nm) there were 44 wavelengths at which a comparison was made. These were treated entirely independently and thus the report describes 44 comparisons. For wavelengths from 250 nm to 800 nm (apart from 300 nm) all participants had unilateral degrees of equivalence (DoEs) with values consistent with their uncertainties for a coverage level k = 2. At all other wavelengths (apart from 1400 nm) all participants achieved consistency at the k = 4 level for the unilateral DoEs and the vast majority within k = 3. The results are a significant improvement over those of the previous comparison in 1990, especially considering that the declared uncertainties of most participants have been substantially improved over the intervening decade. These results are evidence of the value of the effort devoted to the development of improved spectral scales (and of the evaluation of their uncertainty) by many NMIs in recent years. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. KEY COMPARISON: Final report of International Comparison EUROMET.QM-K1c: Comparison of measurements of nitrogen monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, A. M. H.; Nieuwenkamp, G.; Oudwater, R.; Wessel, R. M.; Novak, J.; Perrochet, J.-F.; Ackermann, A.; Rakowska, A.; Cortez, L.; Dias, F.; Konopelko, L.; Kustikov, Y.; Sutour, C.; Masé, T.; Milton, M. J. T.; Uprichard, I. J.; Woods, P. T.; Walden, J.; Lopez Esteban, M. T.

    2005-01-01

    Following-up the key comparison CCQM-K1c, EUROMET organized a regional key comparison involving ten laboratories. The objectives of this EUROMET key comparison were essentially the same as for the CCQM-K1c comparison: to compare the measurement capabilities of national metrological institutes (NMIs) in measuring amount of substance fractions of nitrogen monoxide in nitrogen. The nominal amount of substance fraction of the standards used for the comparison was 100 µmol/mol. The pilot laboratory in this key comparison also piloted the CCQM key comparison and has long-term experience in the behaviour of these mixtures and the technical challenges in preparing batches of very similar mixtures. Most participants used chemiluminescence as the measurement method; two participants used UV techniques and one ND-IR. The degrees of equivalence between this comparison and CCQM-K1c were calculated; four laboratories participated in both key comparisons, thus providing sufficient data for demonstrating the comparability. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  15. Final report, ongoing key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII (December 2014)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2015-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2010)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2011-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with ISCIII, March 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Sanchez, Carmen; Morillo Gomez, Pilar

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on the ongoing key comparison BIPM.QM-K1: Ozone at ambient level, comparison with ISCIII (December 2012)

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Idrees, Faraz; Wielgosz, Robert; Morillo Gomez, Pilar; Sánchez, Carmen

    2013-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Instituto de Salud Carlos III (ISCIII) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NPL, April 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Sweeney, Bryan; Quincey, Paul

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone standard of the United Kingdom maintained by the National Physical Laboratory (NPL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with VSL, September 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Heikens, Dita; van der Veen, Adrian

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Netherlands maintained by the Van Swinden (VSL) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NIST, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Moussay, Philippe; Wielgosz, Robert; Hodges, Joe; Norris, James E.

    2017-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the National Institute of Standards and Technology (NIST) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Comparison of alternative approaches for analysing multi-level RNA-seq data

    PubMed Central

    Mohorianu, Irina; Bretman, Amanda; Smith, Damian T.; Fowler, Emily K.; Dalmay, Tamas

    2017-01-01

    RNA sequencing (RNA-seq) is widely used for RNA quantification in the environmental, biological and medical sciences. It enables the description of genome-wide patterns of expression and the identification of regulatory interactions and networks. The aim of RNA-seq data analyses is to achieve rigorous quantification of genes/transcripts to allow a reliable prediction of differential expression (DE), despite variation in levels of noise and inherent biases in sequencing data. This can be especially challenging for datasets in which gene expression differences are subtle, as in the behavioural transcriptomics test dataset from D. melanogaster that we used here. We investigated the power of existing approaches for quality checking mRNA-seq data and explored additional, quantitative quality checks. To accommodate nested, multi-level experimental designs, we incorporated sample layout into our analyses. We employed a subsampling without replacement-based normalization and an identification of DE that accounted for the hierarchy and amplitude of effect sizes within samples, then evaluated the resulting differential expression call in comparison to existing approaches. In a final step to test for broader applicability, we applied our approaches to a published set of H. sapiens mRNA-seq samples, The dataset-tailored methods improved sample comparability and delivered a robust prediction of subtle gene expression changes. The proposed approaches have the potential to improve key steps in the analysis of RNA-seq data by incorporating the structure and characteristics of biological experiments. PMID:28792517

  4. International comparison on the management system of end-of-life vehicles

    NASA Astrophysics Data System (ADS)

    Wang, Jiaxi; Zhu, Anqi; Zhou, Yaodong

    2017-04-01

    With the rapid development of economy, Chinese vehicle ownership has risen significantly. At the same time, the end-of-life vehicles put a huge pressure to energy and environment, which will finally have an extremely bad effect on sustainable development of economy. The paper takes the United States, the European Union and Japan as samples, compares and analyses these countries’ experiences in law, administration, operation. The key of developed country governance to solve ‘trust’ problem in recycling is its diversity within a complete legal system. At last, the paper gives some suggestions on the issue of Chinese end-of-life vehicles recycling.

  5. Recent results from DAMA/LIBRA - phase1 and perspectives

    NASA Astrophysics Data System (ADS)

    Bernabei, R.; Belli, P.; d'Angelo, S.; Di Marco, A.; Montecchia, F.; d'Angelo, A.; Incicchitti, A.; Cappella, F.; Caracciolo, V.; Cerulli, R.; Dai, C. J.; He, H. L.; Kuang, H. H.; Ma, X. H.; Sheng, X. D.; Wang, R. G.; Ye, Z. P.

    The DAMA/LIBRA{phase1 and the former DAMA/NaI data (cumulative exposure 1:33 ton x yr, corresponding to 14 annual cycles) give evidence at 9.3 σ C.L. for the presence of Dark Matter (DM) particles in the galactic halo, on the basis of the exploited model independent DM annual modulation signature by using highly radiopure NaI(Tl) target. Results and comparisons will be briefly recalled. Recent analyses on possible diurnal ects and on the Earth shadowing effect (the latter holds only for some DM candidates) will be mentioned. Finally, the perspectives of the running DAMA/LIBRA-phase2 will be mentioned.

  6. Final report of key comparison AFRIMETS.AUV.A-K5: primary pressure calibration of LS1P microphones according to IEC 61094-2, over the frequency range 2 Hz to 10 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Avison, J.; Harris, P.; Blabla, M.; Hämäläinen, J.

    2017-01-01

    The degrees of equivalence of the AFRIMETS.AUV.A-K5 regional key comparison are reported here as the final report. The scope of the comparison covered the complex pressure sensitivities of two LS1P microphones over the frequency range 2 Hz to 10 kHz in accordance with IEC 61094-2: 2009. Four national metrology institutes from two different regional metrology organisations participated in the comparison. Two LS1P microphones were circulated simultaneously to all the participants in a circular configuration. One of the microphones sensitivity shifted and all results associated with this microphone were subsequently excluded from further analysis and linking. The AFRIMETS.AUV.A-K5 comparison results were linked to the CCAUV.A-K5 comparison results via dual participation in the CCAUV.A-K5 and AFRIMETS.AUV.A-K5 comparisons. The degrees of equivalence, linked to the CCAUV.A-K5 comparison, were calculated for all participants of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with INECC, September 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Fentanes, Oscar; Benítez, Ángeles; Ordoñez, Daniel

    2018-01-01

    As part of the ongoing key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of Mexico maintained by the National Institute of Ecology and Climate Change (INECC) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM). The instruments have been compared over a nominal ozone amount-of-substance fraction range from 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with CMS-ITRI, June 2016

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Lin, Tsai-Yin; Norris, James E.; Hodges, Joseph T.

    2017-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the ITRI Center for Measurement Standards (CMS-ITRI) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report, on-going key comparison BIPM.QM-K1: ozone at ambient level, comparison with DMDM, July 2015

    NASA Astrophysics Data System (ADS)

    Viallon, J.; Moussay, P.; Wielgosz, R.; Bebic, J.; Norris, J. E.; Guenther, F.

    2016-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of the Directorate of Measures and Precious Metals (DMDM) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Archaeomagnetic research in the United States midcontinent

    NASA Astrophysics Data System (ADS)

    Lengyel, Stacey Nicole

    This dissertation combines archaeomagnetic and independent chronometric data from 240 archaeological features to develop a regional secular variation curve for the U.S. midcontinent. These data were obtained from features located between 31.5--40.5° N latitude and 82.5--93.5° W longitude that have been dated to between 60 and 10,700 cal BP. The archaeomagnetic samples were collected from 41 sites within this region over the past 35 years under the direction of four different researchers: Robert DuBois (University of Oklahoma), Daniel Wolfman (University of Arkansas and New Mexico State Museum), Wulf Gose (University of Texas at Austin), and myself. In this project, the data are initially smoothed through the moving windows method to form the first approximation of the curve. Outlier analyses and pairwise statistical comparisons are utilized to refine the smoothed curve, and the results are compared to other Holocene-aged secular variation records from North America. These analyses indicate that the final curve should be treated as three distinct segments with different precision and use recommendations. First, the 850--75 cal BP segment can be used to date archaeomagnetic sample from the project area with expected temporal precision of 100--200 years. Second, the 2528--850 cal BP segment can be used cautiously to date archaeomagnetic samples with an expected temporal precision of 200--300 years. Third, the 9755--4650 cal BP segment should be used for contextual dating purposes only, in that an undated sample can be put into a regional context through comparison with the segment's constituent samples. Finally, three archaeological problems are addressed through the archaeomagnetic data. First, archaeomagnetic data are used to resolve the temporal conflict between an eastern Tennessee structure's morphology and a much earlier radiocarbon date obtained for the structure. Then, archaeomagnetic data are used to address a number of internal chronology questions regarding three Powers phase sites in eastern Missouri. Finally, the sequencing of several protohistoric and historic sites in eastern Tennessee is examined through a series of archaeomagnetic data.

  11. Effects of thermal cycling parameters on residual stresses in alumina scales of CoNiCrAlY and NiCoCrAlY bond coats

    DOE PAGES

    Nordhorn, Christian; Mücke, Robert; Unocic, Kinga A.; ...

    2014-08-20

    In this paper, furnace cycling experiments were performed on free-standing high-velocity oxygen-fuel bond coat samples to investigate the effect of material composition, surface texture, and cycling conditions on the average stresses in the formed oxide scales after cooling. The oxide scale thicknesses were determined by SEM image analyses and information about the stresses were acquired by photo-stimulated luminescence-spectroscopy. Additionally, the scale thickness dependent stress fields were calculated in finite-element analyses including approximation functions for the surface roughness derived on the basis of profilometry data. The evolution of the average residual stress as a function of oxide scale thickness was subjectmore » to stochastic fluctuations predominantly caused by local scale spallations. In comparison to the supplemental modeling results, thermal stresses due to mismatch of thermal expansion coefficients are identified as the main contribution to the residual stresses. Finally, the theoretical results emphasize that analyses of spectroscopic data acquired for average stress investigations of alumina scales rely on detailed information about microstructural features.« less

  12. A Comparative Study on Emerging Electric Vehicle Technology Assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Jonathan; Khowailed, Gannate; Blackburn, Julia

    2011-03-01

    Numerous organizations have published reports in recent years that investigate the ever changing world of electric vehicle (EV) technologies and their potential effects on society. Specifically, projections have been made on greenhouse gas (GHG) emissions associated with these vehicles and how they compare to conventional vehicles or hybrid electric vehicles (HEVs). Similar projections have been made on the volumes of oil that these vehicles can displace by consuming large amounts of grid electricity instead of petroleum-based fuels. Finally, the projected rate that these new vehicle fleets will enter the market varies significantly among organizations. New ideas, technologies, and possibilities aremore » introduced often, and projected values are likely to be refined as industry announcements continue to be made. As a result, over time, a multitude of projections for GHG emissions, oil displacement, and market penetration associated with various EV technologies has resulted in a wide range of possible future outcomes. This leaves the reader with two key questions: (1) Why does such a collective range in projected values exist in these reports? (2) What assumptions have the greatest impact on the outcomes presented in these reports? Since it is impractical for an average reader to review and interpret all the various vehicle technology reports published to date, Sentech Inc. and the Oak Ridge National Laboratory have conducted a comparative study to make these interpretations. The primary objective of this comparative study is to present a snapshot of all major projections made on GHG emissions, oil displacement, or market penetration rates of EV technologies. From the extensive data found in relevant publications, the key assumptions that drive each report's analysis are identified and 'apples-to-apples' comparisons between all major report conclusions are attempted. The general approach that was taken in this comparative study is comprised of six primary steps: (1) Search Relevant Literature - An extensive search of recent analyses that address the environmental impacts, market penetration rates, and oil displacement potential of various EV technologies was conducted; (2) Consolidate Studies - Upon completion of the literature search, a list of analyses that have sufficient data for comparison and that should be included in the study was compiled; (3) Identify Key Assumptions - Disparity in conclusions very likely originates from disparity in simple assumptions. In order to compare 'apples-to-apples,' key assumptions were identified in each study to provide the basis for comparing analyses; (4) Extract Information - Each selected report was reviewed, and information on key assumptions and data points was extracted; (5) Overlay Data Points - Visual representations of the comprehensive conclusions were prepared to identify general trends and outliers; and (6) Draw Final Conclusions - Once all comparisons are made to the greatest possible extent, the final conclusions were draw on what major factors lead to the variation in results among studies.« less

  13. Comparison Between Laser Scanning and Automated 3d Modelling Techniques to Reconstruct Complex and Extensive Cultural Heritage Areas

    NASA Astrophysics Data System (ADS)

    Fassi, F.; Fregonese, L.; Ackermann, S.; De Troia, V.

    2013-02-01

    In Cultural Heritage field, the necessity to survey objects in a fast manner, with the ability to repeat the measurements several times for deformation or degradation monitoring purposes, is increasing. In this paper, two significant cases, an architectonical one and an archaeological one, are presented. Due to different reasons and emergency situations, the finding of the optimal solution to enable quick and well-timed survey for a complete digital reconstruction of the object is required. In both cases, two survey methods have been tested and used: a laser scanning approach that allows to obtain high-resolution and complete scans within a short time and a photogrammetric one that allows the three-dimensional reconstruction of the object from images. In the last months, several methodologies, including free or low cost techniques, have arisen. These kinds of software allow the fully automatically three-dimensional reconstruction of objects from images, giving back a dense point cloud and, in some case, a surfaced mesh model. In this paper some comparisons between the two methodologies above mentioned are presented, using the example of some real cases of study. The surveys have been performed by employing both photogrammetry and laser scanner techniques. The methodological operational choices, depending on the required goal, the difficulties encountered during the survey with these methods, the execution time (that is the key parameter), and finally the obtained results, are fully described and examinated. On the final 3D model, an analytical comparison has been made, to analyse the differences, the tolerances, the possibility of accuracy improvement and the future developments.

  14. Macroscopic Neural Theories of Cognition

    DTIC Science & Technology

    2014-03-01

    Autobiographical Memory -- 51% • Emotional Face Processing -- 14% • Single Word Reading -- 45% • N-Back Working Memory – 41% 22 A graphic comparison of...seven meta-analyses carried out for working memory is shown in Table 2. The results of this comparison were also clear—there was substantial...variation among the areas reported by the seven meta-analyses. Table 2. A Comparison of Seven Meta-analyses dealing with Working Memory . (Uttal, 2013

  15. Forced Mixer Nozzle Optimization

    NASA Technical Reports Server (NTRS)

    Sheoran, Yogi; Hoover, Robert; Schuster, William; Anderson, Morris; Weir, Donald S.

    1999-01-01

    Computational fluid dynamic (CFD) and computational acoustic analyses (CAA) were performed for a TFE731-40 compound nozzle, a TFE731-60 mixer nozzle and an Energy Efficient Engine (E(sup 3)) mixer nozzle for comparison with available data. The CFD analyses were performed with a three dimensional, Navier-Stokes solution of the flowfield on an unstructured grid using the RAMPANT program. The CAA analyses were performed with the NASA Glenn MGB program using a structured grid. A successful aerodynamic solution for the TFE731-40 compound nozzle operating statically was obtained, simulating an engine operating on a test stand. Analysis of the CFD results of the TFE731-40 with the MGB program produced predicted sound power levels that agree quite well with the measured data front full-scale static engine tests. Comparison of the predicted sound pressure with the data show good agreement near the jet axis, but the noise levels are overpredicted at angles closer to the inlet. The predicted sound power level for the TFE731-60 did not agree as well with measured static engine data as the TFE731-40. Although a reduction in the predicted noise level due to the mixed flow was observed, the reduction was not as significant as the measured data. The analysis of the V2 mixer from the E(sup 3) study showed that peak temperatures predicted in the mixer exit flowfield were within 5 percent of the values measured by the exit probes. The noise predictions of the V2 mixer nozzle tended to be 3-5 dB higher in peak noise level than the measurements. In addition, the maximum frequency of the noise was also overpredicted. An analysis of the 3 candidate mixer nozzle configurations demonstrated the feasibility of using centerbody lobes and porosity to improve mixing efficiency. A final configuration was designed with a predicted thermal mixing efficiency that was 5 percent higher than the 3 candidate mixers. The results of the MGB noise calculations show that the final design will exceed the design goal of a 3 dB reduction in noise as compared to the baseline TFE731-40.

  16. Analyzing the Impacts of Dams on Riparian Ecosystems: A Review of Research Strategies and Their Relevance to the Snake River Through Hells Canyon

    PubMed Central

    Braatne, Jeffrey H.; Goater, Lori A.; Blair, Charles L.

    2007-01-01

    River damming provides a dominant human impact on river environments worldwide, and while local impacts of reservoir flooding are immediate, subsequent ecological impacts downstream can be extensive. In this article, we assess seven research strategies for analyzing the impacts of dams and river flow regulation on riparian ecosystems. These include spatial comparisons of (1) upstream versus downstream reaches, (2) progressive downstream patterns, or (3) the dammed river versus an adjacent free-flowing or differently regulated river(s). Temporal comparisons consider (4) pre- versus post-dam, or (5) sequential post-dam conditions. However, spatial comparisons are complicated by the fact that dams are not randomly located, and temporal comparisons are commonly limited by sparse historic information. As a result, comparative approaches are often correlative and vulnerable to confounding factors. To complement these analyses, (6) flow or sediment modifications can be implemented to test causal associations. Finally, (7) process-based modeling represents a predictive approach incorporating hydrogeomorphic processes and their biological consequences. In a case study of Hells Canyon, the upstream versus downstream comparison is confounded by a dramatic geomorphic transition. Comparison of the multiple reaches below the dams should be useful, and the comparison of Snake River with the adjacent free-flowing Salmon River may provide the strongest spatial comparison. A pre- versus post-dam comparison would provide the most direct study approach, but pre-dam information is limited to historic reports and archival photographs. We conclude that multiple study approaches are essential to provide confident interpretations of ecological impacts downstream from dams, and propose a comprehensive study for Hells Canyon that integrates multiple research strategies. PMID:18043964

  17. The Visual Analogue Scale for Rating, Ranking and Paired-Comparison (VAS-RRP): A new technique for psychological measurement.

    PubMed

    Sung, Yao-Ting; Wu, Jeng-Shin

    2018-04-17

    Traditionally, the visual analogue scale (VAS) has been proposed to overcome the limitations of ordinal measures from Likert-type scales. However, the function of VASs to overcome the limitations of response styles to Likert-type scales has not yet been addressed. Previous research using ranking and paired comparisons to compensate for the response styles of Likert-type scales has suffered from limitations, such as that the total score of ipsative measures is a constant that cannot be analyzed by means of many common statistical techniques. In this study we propose a new scale, called the Visual Analogue Scale for Rating, Ranking, and Paired-Comparison (VAS-RRP), which can be used to collect rating, ranking, and paired-comparison data simultaneously, while avoiding the limitations of each of these data collection methods. The characteristics, use, and analytic method of VAS-RRPs, as well as how they overcome the disadvantages of Likert-type scales, ranking, and VASs, are discussed. On the basis of analyses of simulated and empirical data, this study showed that VAS-RRPs improved reliability, response style bias, and parameter recovery. Finally, we have also designed a VAS-RRP Generator for researchers' construction and administration of their own VAS-RRPs.

  18. Final report of supplementary comparison AFRIMETS.AUV.A-S1: primary pressure calibration of LS2aP microphones according to IEC 61094-2, over the frequency range 1 Hz to 31.5 kHz.

    NASA Astrophysics Data System (ADS)

    Nel, R.; Barrera-Figueroa, S.; Dobrowolska, D.; Defilippo Soares, Z. M.; Maina, A. K.; Hof, C.

    2016-01-01

    This is the final report of the AFRIMETS.AUV-S1 comparison of the pressure sensitivity, modulus and phase, of LS2aP microphones in the frequency range 1 Hz to 31.5 kHz in accordance with IEC 61094-2. Six national metrology institutes from three different regional metrology organisations participated in the comparison for which two LS2aP microphones were circulated simultaneously to all the participants in a hybrid-star configuration. The comparison reference values were calculated as the weighted mean for modulus and phase for each individual microphone. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Biases and Power for Groups Comparison on Subjective Health Measurements

    PubMed Central

    Hamel, Jean-François; Hardouin, Jean-Benoit; Le Neel, Tanguy; Kubis, Gildas; Roquelaure, Yves; Sébille, Véronique

    2012-01-01

    Subjective health measurements are increasingly used in clinical research, particularly for patient groups comparisons. Two main types of analytical strategies can be used for such data: so-called classical test theory (CTT), relying on observed scores and models coming from Item Response Theory (IRT) relying on a response model relating the items responses to a latent parameter, often called latent trait. Whether IRT or CTT would be the most appropriate method to compare two independent groups of patients on a patient reported outcomes measurement remains unknown and was investigated using simulations. For CTT-based analyses, groups comparison was performed using t-test on the scores. For IRT-based analyses, several methods were compared, according to whether the Rasch model was considered with random effects or with fixed effects, and the group effect was included as a covariate or not. Individual latent traits values were estimated using either a deterministic method or by stochastic approaches. Latent traits were then compared with a t-test. Finally, a two-steps method was performed to compare the latent trait distributions, and a Wald test was performed to test the group effect in the Rasch model including group covariates. The only unbiased IRT-based method was the group covariate Wald’s test, performed on the random effects Rasch model. This model displayed the highest observed power, which was similar to the power using the score t-test. These results need to be extended to the case frequently encountered in practice where data are missing and possibly informative. PMID:23115620

  20. Final report of international comparison APMP.QM-S2.2015 of oxygen in nitrogen at 0.2 mol/mol

    NASA Astrophysics Data System (ADS)

    Aoki, Nobuyuki; Shimosaka, Takuya; Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Wongjuk, Arnuttachai; Rattanasombat, Soponrat; Sinweeruthai, Ratirat; Uehara, Shinji; Aleksandrov, Vladimir

    2017-01-01

    This document describes the results of the supplementary comparison for oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction of oxygen is 0.20 mol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Final report, on-going key comparison BIPM.QM-K1, ozone at ambient level, comparison with NMISA, June 2017

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert; Ntsasa, Napo G.; Tshilongo, James; Mphaphuli, Gumani E.; Norris, James E.; Hodges, Joseph T.

    2018-01-01

    As part of the on-going key comparison BIPM.QM-K1, a comparison has been performed between the ozone national standard of South Africa maintained by the National Metrology Institute of South Africa (NMISA) and the common reference standard of the key comparison, maintained by the Bureau International des Poids et Mesures (BIPM), via a transfer standard maintained by the National Institute of Standards and Technology (NIST). The instruments have been compared over a nominal ozone amount-of-substance fraction range of 0 nmol/mol to 500 nmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Kinematic and Hydrometer Data Products from Scanning Radars during MC3E

    DOE Data Explorer

    matthews, Alyssa; Dolan, Brenda; Rutledge, Steven

    2016-02-29

    Recently the Radar Meteorology Group at Colorado State University has completed major case studies of some top cases from MC3E including 25 April, 20 May and 23 May 2011. A discussion on the analysis methods as well as radar quality control methods is included. For each case, a brief overview is first provided. Then, multiple Doppler (using available X-SAPR and C-SAPR data) analyses are presented including statistics on vertical air motions, sub-divided by convective and stratiform precipitation. Mean profiles and CFAD's of vertical motion are included to facilitate comparison with ASR model simulations. Retrieved vertical motion has also been verified with vertically pointing profiler data. Finally for each case, hydrometeor types are included derived from polarimetric radar observations. The latter can be used to provide comparisons to model-generated hydrometeor fields. Instructions for accessing all the data fields are also included. The web page can be found at: http://radarmet.atmos.colostate.edu/mc3e/research/

  3. Well-being as a moving target: measurement equivalence of the Bradburn Affect Balance Scale.

    PubMed

    Maitland, S B; Dixon, R A; Hultsch, D F; Hertzog, C

    2001-03-01

    Although the Bradburn Affect Balance scale (ABS) is a frequently used two-factor indicator of well-being in later life, its measurement and invariance properties are not well documented. We examined these issues using confirmatory factor analyses of cross-sectional (adults ages 54-87 years) and longitudinal data from the Victoria Longitudinal Study. Stability of the positive and negative affect factors was moderate across a 3-year period. Overall, factor loadings for positive affect items were invariant over time with the exception of the pleased item. Negative affect items were time invariant. However, age-group comparisons between young-old and old-old groups revealed age differences in loadings for the upset item at Time 1. Finally, gender groups differed in loadings for the top of the world and going your way items. Thus a pattern of partial measurement equivalence characterized item response to the ABS. Our results suggest that group comparisons and longitudinal change in ABS scale scores of positive and negative affect should be interpreted with caution.

  4. An ANOVA approach for statistical comparisons of brain networks.

    PubMed

    Fraiman, Daniel; Fraiman, Ricardo

    2018-03-16

    The study of brain networks has developed extensively over the last couple of decades. By contrast, techniques for the statistical analysis of these networks are less developed. In this paper, we focus on the statistical comparison of brain networks in a nonparametric framework and discuss the associated detection and identification problems. We tested network differences between groups with an analysis of variance (ANOVA) test we developed specifically for networks. We also propose and analyse the behaviour of a new statistical procedure designed to identify different subnetworks. As an example, we show the application of this tool in resting-state fMRI data obtained from the Human Connectome Project. We identify, among other variables, that the amount of sleep the days before the scan is a relevant variable that must be controlled. Finally, we discuss the potential bias in neuroimaging findings that is generated by some behavioural and brain structure variables. Our method can also be applied to other kind of networks such as protein interaction networks, gene networks or social networks.

  5. Polar motion excitation analysis due to global continental water redistribution

    NASA Astrophysics Data System (ADS)

    Fernandez, L.; Schuh, H.

    2006-10-01

    We present the results obtained when studying the hydrological excitation of the Earth‘s wobble due to global redistribution of continental water storage. This work was performed in two steps. First, we computed the hydrological angular momentum (HAM) time series based on the global hydrological model LaD (Land Dynamics model) for the period 1980 till 2004. Then, we compared the effectiveness of this excitation by analysing the residuals of the geodetic time series after removing atmospheric and oceanic contributions with the respective hydrological ones. The emphasis was put on low frequency variations. We also present a comparison of HAM time series from LaD with respect to that one from a global model based on the assimilated soil moisture and snow accumulation data from NCEP/NCAR (The National Center for Environmental Prediction/The National Center for Atmospheric Research) reanalysis. Finally, we evaluate the performance of LaD model in closing the polar motion budget at seasonal periods in comparison with the NCEP and the Land Data Assimilation System (LDAS) models.

  6. Analysis of the Efficacy of an Intervention to Improve Parent-Adolescent Problem Solving.

    PubMed

    Semeniuk, Yulia Yuriyivna; Brown, Roger L; Riesch, Susan K

    2016-07-01

    We conducted a two-group longitudinal partially nested randomized controlled trial to examine whether young adolescent youth-parent dyads participating in Mission Possible: Parents and Kids Who Listen, in contrast to a comparison group, would demonstrate improved problem-solving skill. The intervention is based on the Circumplex Model and Social Problem-Solving Theory. The Circumplex Model posits that families who are balanced, that is characterized by high cohesion and flexibility and open communication, function best. Social Problem-Solving Theory informs the process and skills of problem solving. The Conditional Latent Growth Modeling analysis revealed no statistically significant differences in problem solving among the final sample of 127 dyads in the intervention and comparison groups. Analyses of effect sizes indicated large magnitude group effects for selected scales for youth and dyads portraying a potential for efficacy and identifying for whom the intervention may be efficacious if study limitations and lessons learned were addressed. © The Author(s) 2016.

  7. On the study of oil paint adhesion on optically transparent glass: Conservation of reverse paintings on glass

    NASA Astrophysics Data System (ADS)

    Bayle, M.; Waugh, D. G.; Colston, B. J.; Lawrence, J.

    2015-12-01

    Reverse painting on glass is a technique which consists of applying a cold paint layer on the reverse-side of glass. The main challenge facing these artworks is the fragile adhesion of the pictorial layer - a simple movement can modify the appearance of the painting. This paper details a study into the adhesion parameters of pigments on glass and the comparison between different pigments. The relationships between the binder (linseed oil) with pigments and the glass with or without the use of an adhesive are studied. Physical analyses by surface characterisation have been carried out to better understand the influence of the pigment. The use of a sessile drop device, optical microscopy, scanning electron microscopy (SEM), a surface 3D profiler and a pencil hardness scratch tester were necessary to establish a comparison of the pictorial layer adhesion. A comparison of the effect of two adhesives, namely ox gall and gum arabic, has shown that the adhesion is not only linked to the physical parameters but that possible chemical reactions can influence the results. Finally, a treatment based on humidity-extreme storage has shown the weakness of some pictorial layers.

  8. Microarray analyses of Xylella fastidiosa provide evidence of coordinated transcription control of laterally transferred elements.

    PubMed

    Nunes, Luiz R; Rosato, Yoko B; Muto, Nair H; Yanai, Giane M; da Silva, Vivian S; Leite, Daniela B; Gonçalves, Edmilson R; de Souza, Alessandra A; Coletta-Filho, Helvécio D; Machado, Marcos A; Lopes, Silvio A; de Oliveira, Regina Costa

    2003-04-01

    Genetically distinct strains of the plant bacterium Xylella fastidiosa (Xf) are responsible for a variety of plant diseases, accounting for severe economic damage throughout the world. Using as a reference the genome of Xf 9a5c strain, associated with citrus variegated chlorosis (CVC), we developed a microarray-based comparison involving 12 Xf isolates, providing a thorough assessment of the variation in genomic composition across the group. Our results demonstrate that Xf displays one of the largest flexible gene pools characterized to date, with several horizontally acquired elements, such as prophages, plasmids, and genomic islands (GIs), which contribute up to 18% of the final genome. Transcriptome analysis of bacteria grown under different conditions shows that most of these elements are transcriptionally active, and their expression can be influenced in a coordinated manner by environmental stimuli. Finally, evaluation of the genetic composition of these laterally transferred elements identified differences that may help to explain the adaptability of Xf strains to infect such a wide range of plant species.

  9. Theoretical Mathematics

    NASA Astrophysics Data System (ADS)

    Stöltzner, Michael

    Answering to the double-faced influence of string theory on mathematical practice and rigour, the mathematical physicists Arthur Jaffe and Frank Quinn have contemplated the idea that there exists a `theoretical' mathematics (alongside `theoretical' physics) whose basic structures and results still require independent corroboration by mathematical proof. In this paper, I shall take the Jaffe-Quinn debate mainly as a problem of mathematical ontology and analyse it against the backdrop of two philosophical views that are appreciative towards informal mathematical development and conjectural results: Lakatos's methodology of proofs and refutations and John von Neumann's opportunistic reading of Hilbert's axiomatic method. The comparison of both approaches shows that mitigating Lakatos's falsificationism makes his insights about mathematical quasi-ontology more relevant to 20th century mathematics in which new structures are introduced by axiomatisation and not necessarily motivated by informal ancestors. The final section discusses the consequences of string theorists' claim to finality for the theory's mathematical make-up. I argue that ontological reductionism as advocated by particle physicists and the quest for mathematically deeper axioms do not necessarily lead to identical results.

  10. Final report on bilateral comparison SIM.EM-S9.b: Comparison of resistance standards at 1 Ω and 10 kΩ between INIMET (Cuba) and INTI (Argentina), March to October 2012

    NASA Astrophysics Data System (ADS)

    Tonina, A.; Currás, M.; Navarro, M.

    2014-01-01

    The CIPM MRA states that its technical basis is a set of results obtained in a course of time through key comparisons carried out by the Consultative Committees of the CIPM, the BIPM and the Regional Metrology Organizations (RMOs). As part of this process, INTI (Argentina) has participated in several key and supplementary comparisons. By means of procedures for linking key comparison data, a bilateral comparison would help to provide assurance of equality in measurements between the participating laboratories. With this end, the comparison SIM.EM-S9.b of 1 ohm and 10 kiloohm standard resistors of INIMET (Cuba) and INTI was carried out from March to October 2012. The obtained results were very good. They show that the resistance standards maintained by INTI and INIMET were equivalent, within their combined uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Fractal Analyses of High-Resolution Cloud Droplet Measurements.

    NASA Astrophysics Data System (ADS)

    Malinowski, Szymon P.; Leclerc, Monique Y.; Baumgardner, Darrel G.

    1994-02-01

    Fractal analyses of individual cloud droplet distributions using aircraft measurements along one-dimensional horizontal cross sections through clouds are performed. Box counting and cluster analyses are used to determine spatial scales of inhomogeneity of cloud droplet spacing. These analyses reveal that droplet spatial distributions do not exhibit a fractal behavior. A high variability in local droplet concentration in cloud volumes undergoing mixing was found. In these regions, thin filaments of cloudy air with droplet concentration close to those observed in cloud cores were found. Results suggest that these filaments may be anisotropic. Additional box counting analyses performed for various classes of cloud droplet diameters indicate that large and small droplets are similarly distributed, except for the larger characteristic spacing of large droplets.A cloud-clear air interface defined by a certain threshold of total droplet count (TDC) was investigated. There are indications that this interface is a convoluted surface of a fractal nature, at least in actively developing cumuliform clouds. In contrast, TDC in the cloud interior does not have fractal or multifractal properties. Finally a random Cantor set (RCS) was introduced as a model of a fractal process with an ill-defined internal scale. A uniform measure associated with the RCS after several generations was introduced to simulate the TDC records. Comparison of the model with real TDC records indicates similar properties of both types of data series.

  12. Prediction of external corrosion for steel cylinders at the Paducah Gaseous Diffusion Plant: Application of an empirical method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyon, B.F.

    1996-02-01

    During the summer of 1995, ultrasonic wall thickness data were collected for 100 steel cylinders containing depleted uranium (DU) hexafluoride located at Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky. The cylinders were selected for measurement to assess the condition of the more vulnerable portion of the cylinder inventory at PGDP. The purpose of this report is to apply the method used in Lyon to estimate the effects of corrosion for larger unsampled populations as a function of time. The scope of this report is limited and is not intended to represent the final analyses of available data. Future effortsmore » will include continuing analyses of available data to investigate defensible deviations from the conservative assumptions made to date. For each cylinder population considered, two basic types of analyses were conducted: (1) estimates were made of the number of cylinders as a function of time that will have a minimum wall thickness of either 0 mils (1 mil = 0.00 1 in.) or 250 mils and (2) the current minimum wall thickness distributions across cylinders were estimated for each cylinder population considered. Additional analyses were also performed investigating comparisons of the results for F and G yards with the results presented in Lyon (1995).« less

  13. Reporting quality of statistical methods in surgical observational studies: protocol for systematic review.

    PubMed

    Wu, Robert; Glen, Peter; Ramsay, Tim; Martel, Guillaume

    2014-06-28

    Observational studies dominate the surgical literature. Statistical adjustment is an important strategy to account for confounders in observational studies. Research has shown that published articles are often poor in statistical quality, which may jeopardize their conclusions. The Statistical Analyses and Methods in the Published Literature (SAMPL) guidelines have been published to help establish standards for statistical reporting.This study will seek to determine whether the quality of statistical adjustment and the reporting of these methods are adequate in surgical observational studies. We hypothesize that incomplete reporting will be found in all surgical observational studies, and that the quality and reporting of these methods will be of lower quality in surgical journals when compared with medical journals. Finally, this work will seek to identify predictors of high-quality reporting. This work will examine the top five general surgical and medical journals, based on a 5-year impact factor (2007-2012). All observational studies investigating an intervention related to an essential component area of general surgery (defined by the American Board of Surgery), with an exposure, outcome, and comparator, will be included in this systematic review. Essential elements related to statistical reporting and quality were extracted from the SAMPL guidelines and include domains such as intent of analysis, primary analysis, multiple comparisons, numbers and descriptive statistics, association and correlation analyses, linear regression, logistic regression, Cox proportional hazard analysis, analysis of variance, survival analysis, propensity analysis, and independent and correlated analyses. Each article will be scored as a proportion based on fulfilling criteria in relevant analyses used in the study. A logistic regression model will be built to identify variables associated with high-quality reporting. A comparison will be made between the scores of surgical observational studies published in medical versus surgical journals. Secondary outcomes will pertain to individual domains of analysis. Sensitivity analyses will be conducted. This study will explore the reporting and quality of statistical analyses in surgical observational studies published in the most referenced surgical and medical journals in 2013 and examine whether variables (including the type of journal) can predict high-quality reporting.

  14. Seismic behavior of a low-rise horizontal cylindrical tank

    NASA Astrophysics Data System (ADS)

    Fiore, Alessandra; Rago, Carlo; Vanzi, Ivo; Greco, Rita; Briseghella, Bruno

    2018-05-01

    Cylindrical storage tanks are widely used for various types of liquids, including hazardous contents, thus requiring suitable and careful design for seismic actions. The study herein presented deals with the dynamic analysis of a ground-based horizontal cylindrical tank containing butane and with its safety verification. The analyses are based on a detailed finite element (FE) model; a simplified one-degree-of-freedom idealization is also set up and used for verification of the FE results. Particular attention is paid to sloshing and asynchronous seismic input effects. Sloshing effects are investigated according to the current literature state of the art. An efficient methodology based on an "impulsive-convective" decomposition of the container-fluid motion is adopted for the calculation of the seismic force. The effects of asynchronous ground motion are studied by suitable pseudo-static analyses. Comparison between seismic action effects, obtained with and without consideration of sloshing and asynchronous seismic input, shows a rather important influence of these conditions on the final results.

  15. Finite element analyses of continuous filament ties for masonry applications : final report for the Arquin Corporation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinones, Armando, Sr.; Bibeau, Tiffany A.; Ho, Clifford Kuofei

    2008-08-01

    Finite-element analyses were performed to simulate the response of a hypothetical vertical masonry wall subject to different lateral loads with and without continuous horizontal filament ties laid between rows of concrete blocks. A static loading analysis and cost comparison were also performed to evaluate optimal materials and designs for the spacers affixed to the filaments. Results showed that polypropylene, ABS, and polyethylene (high density) were suitable materials for the spacers based on performance and cost, and the short T-spacer design was optimal based on its performance and functionality. Simulations of vertical walls subject to static loads representing 100 mph windsmore » (0.2 psi) and a seismic event (0.66 psi) showed that the simulated walls performed similarly and adequately when subject to these loads with and without the ties. Additional simulations and tests are required to assess the performance of actual walls with and without the ties under greater loads and more realistic conditions (e.g., cracks, non-linear response).« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, Wade C.

    Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 andmore » S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.« less

  17. Final report on EURAMET.QM-S10/1274: supplementary comparison of preparative capabilities for automotive gas mixtures

    NASA Astrophysics Data System (ADS)

    Val'ková, M.; Ďurišová, Z.; Szilágyi, Z. N.; Büki, T.; Fükű, J.

    2016-01-01

    This bilateral supplementary preparative comparison involves standard gas mixtures of automotive gas containing carbon monoxide, carbon dioxide and propane in nitrogen. Two laboratories (SMU, Slovakia and MKEH, Hungary) participated in this supplementary comparison. SMU was the coordinating laboratory, responsible for collecting and reporting measurement results. The participants have established facilities for automotive gas gravimetric preparation and analysis. The agreement of the results in this supplementary comparison is good. All the results with their reported uncertainties are in agreement with the reference values for the participants. SMU participated and obtained good results in the previous preparative comparison organised within EURAMET in this field. Both laboratories have existing claims for their Calibration and Measurement Capabilities (CMCs) for automotive gas mixtures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report of the SIM.QM-S8 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Mester, Zoltan; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola

    2018-01-01

    After completing a supplementary comparison SIM.QM-S7, the National Metrology Institute of Colombia (NMIC) requested to National Research Council of Canada (NRC) a subsequent bilateral comparison, because INMC considered that its results in SIM.QM-S7 unrepresentative of its standards. In this context, NRC agreed to coordinate this bilateral comparison with the aim of demonstrating the measurement capabilities of trace elements in fresh water. Participants included NMIC and LATU. No measurement method was prescribed by the coordinating laboratory. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S8 Supplementary Comparison provides NMIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. KEY COMPARISON: Final report of EUROMET Project 696: pH determination of a phthalate buffer

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Charlet, Philippe; Eberhard, Ralf; Karpov, Oleg V.; Philippe, Rachel; Rivier, Cedric; Maximov, Igor; Sudmeier, Uwe

    2005-01-01

    The EUROMET project 696, a trilateral comparison between PTB, Germany, LNE, France and VNIIFTRI, Russia was performed in order to demonstrate and document the capability of the participants to measure the pH of a phthalate buffer by the primary measurement procedure for pH. Good agreement of the reported results was observed. The sample was very similar to the one used in the comparison CCQM-K17. PTB acts as pilot laboratory in CCQM-K17 and in EUROMET 696. This comparison allows one to link the results obtained by LNE to the CCQM-K17 key comparison through the degree of equivalence of PTB. On the other hand, the discrepancy between measured pH values at the VNIIFTRI and PTB for the same type of buffer solution decreased, as compared with a bilateral comparison in 1997. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  20. Final report of EURAMET 1197: Supplementary bilateral comparison of hydraulic gauge pressure standards up to 50 MPa

    NASA Astrophysics Data System (ADS)

    Durgut, Yasin; Petrovski, Nenad; Kacarski, Vanco

    2012-01-01

    Interlaboratory comparisons are important for the laboratories to assess their own measurement capability. It is equally important for the accreditation bodies and assessors during the audit process of a laboratory to judge whether the laboratory is doing well. As per accreditation rules, it is mandatory for the testing and calibration laboratories to participate in such comparisons from time to time. In this report, results of the bilateral interlaboratory comparison in pressure area in hydraulic media up to 50 MPa gauge between UME (Turkey) and BOM (The FYR of Macedonia) are presented. The artefact used for the comparison was a digital pressure calibrator and its drift was taken into account in the calculation. Results show that all En values lie in acceptable limits. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Bilateral key comparison on luminous flux COOMET.PR-K4.1. final report

    NASA Astrophysics Data System (ADS)

    Huriev, M.; Khlevnoy, B.; Tolstykh, G.; Ivashin, E.; Gorchkova, T.

    2017-01-01

    This report describes an international bilateral key comparison on luminous flux of tungsten lamps between the National Scientific Centre 'Institute of Metrology' (NSC 'IM', Ukraine) and All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI, Russia). The comparison is intended to determine the Degrees of Equivalence (DoE) for NSC 'IM' and the associated expanded uncertainty. VNIIOFI acts as a laboratory, providing the link to the comparison CCPR-K4. The comparison used a set of tungsten incandescent lamps as a transfer standard with a luminous flux of approximately 3800 lm. The determined DoE of NSC 'IM' is -0.94% with an expanded uncertainty (k = 2) of 1.05%. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Final report on COOMET Vickers PTB/VNIIFTRI key comparison (COOMET.M.H-K1.b and COOMET.M.H-K1.c)

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Herrmann, K.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales of two National Metrology Institutes—PTB and VNIIFTRI. The pilot laboratory was PTB, which was the linking institute with the key comparison reference values of CCM.H-K1. In the key comparison two sets of hardness reference blocks for the Vickers hardness scales HV1 and HV30, each consisting of three hardness reference blocks with the hardness levels 240 HV, 540 HV and 840 HV, are used. The same hardness reference blocks were used previously in the key comparison CCM.H-K1. The measurement results and uncertainty assessments, announced by VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. SUPPLEMENTARY COMPARISON: COOMET.RI(II)-S1.Rn-222 (169/UA/98): Rn-222 volume activity comparison

    NASA Astrophysics Data System (ADS)

    Skliarov, V.; Röttger, A.; Honig, A.; Korostin, S.; Kuznetsov, S.; Lapenas, A.; Milevsky, V.; Ivaniukovich, A.; Kharitonov, I.; Sepman, S.

    2009-01-01

    According to a first program, a supplementary comparison of Rn-222 volume activity was drawn up as a bilateral supplementary comparison between NSC 'Institute of Metrology', Ukraine, and VNIIFTRI, Russia. It took place in March 2005. In April 2005, at the 5th meeting of COOMET held in Braunschweig (Germany), representatives of these institutes exchanged data which showed the comparability of the national standards of Ukraine and Russia for the check points. During the discussion of the procedure some other institutes decided to join the comparison program, which was extended to BelGIM (Belarus), PTB (Germany), VNIIM (Russia) and RMTC (Latvia). The national standards of volume activity of radon-222 were thus calibrated using one standard radon radiometer as the transfer standard. Results are shown in the Final Report of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by COOMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Comparison-Bot: an Automated Preliminary-Final Report Comparison System.

    PubMed

    Kalaria, Amit D; Filice, Ross W

    2016-06-01

    Regular comparison of preliminary to final reports is a critical part of radiology resident and fellow education as prior research has documented substantial preliminary to final discrepancies. Unfortunately, there are many barriers to this comparison: high study volume; overnight rotations without an attending; the ability to finalize reports remotely; the subtle nature of many changes; and lack of easy access to the preliminary report after finalization. We developed a system that automatically compiles and emails a weekly summary of report differences for all residents and fellows. Trainees can also create a custom report using a date range of their choice and can view this data on a resident dashboard. Differences between preliminary and final reports are clearly highlighted with links to the associated study in Picture Archiving and Communication Systems (PACS) for efficient review and learning. Reports with more changes, particularly changes made in the impression, are highlighted to focus attention on those exams with substantive edits. Our system provides an easy way for trainees to review changes to preliminary reports with immediate access to the associated images, thereby improving their educational experience. Departmental surveys showed that our report difference summary is easy to understand and improves the educational experience of our trainees. Additionally, interesting descriptive statistics help us understand how reports are changed by trainee level, by attending, and by exam type. Finally, this system can be easily ported to other departments who have access to their Health Level 7 (HL7) data.

  5. Ares I-X Separation and Reentry Trajectory Analyses

    NASA Technical Reports Server (NTRS)

    Tartabini, Paul V.; Starr, Brett R.

    2011-01-01

    The Ares I-X Flight Test Vehicle was launched on October 28, 2009 and was the first and only test flight of NASA s two-stage Ares I launch vehicle design. The launch was successful and the flight test met all of its primary and secondary objectives. This paper discusses the stage separation and reentry trajectory analysis that was performed in support of the Ares I-X test flight. Pre-flight analyses were conducted to assess the risk of stage recontact during separation, to evaluate the first stage flight dynamics during reentry, and to define the range safety impact ellipses of both stages. The results of these pre-flight analyses were compared with available flight data. On-board video taken during flight showed that the flight test vehicle successfully separated without any recontact. Reconstructed trajectory data also showed that first stage flight dynamics were well characterized by pre-flight Monte Carlo results. In addition, comparisons with flight data indicated that the complex interference aerodynamic models employed in the reentry simulation were effective in capturing the flight dynamics during separation. Finally, the splash-down locations of both stages were well within predicted impact ellipses.

  6. Final report on APMP.M.M.K4.1—bilateral comparison of 1 kg stainless steel mass standards between KRISS and A*STAR

    NASA Astrophysics Data System (ADS)

    Chung, J. W.; Lee, S. M.; Lee, S. J.

    2017-01-01

    This report describes a bilateral comparison of 1 kg stainless steel mass standard between the Korea Research Institute of Standards and Science (KRISS), and the National Measurement Centre, Agency for Science, Technology and Research (A*STAR), Singapore, which is registered in the BIPM KCDB as APMP.M.M-K4.1. This nominal value was chosen as it followed the nominal value of CCM.M-K4. This bilateral comparison was piloted by KRISS. The transfer weight was delivered to A*STAR from KRISS in April 2015 and received back from A*STAR in October 2015. A*STAR are aiming to improve their calibration measurement capability (CMC) for mass of 1 kg. KRISS participated in both this comparison and CCM.M-K4, providing a link between the A*STAR result and the KCRV of CCM.M-K4. The final report of this comparison is given in this document. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Aberrant functioning of the putamen links delusions, antipsychotic drug dose, and compromised connectivity in first episode psychosis--Preliminary fMRI findings.

    PubMed

    Raij, Tuukka T; Mäntylä, Teemu; Kieseppä, Tuula; Suvisaari, Jaana

    2015-08-30

    The dopamine theory proposes the relationship of delusions to aberrant signaling in striatal circuitries that can be normalized with dopamine D2 receptor-blocking drugs. Localization of such circuitries, as well as their upstream and downstream signaling, remains poorly known. We collected functional magnetic resonance images from first-episode psychosis patients and controls during an audiovisual movie. Final analyses included 20 patients and 20 controls; another sample of 10 patients and 10 controls was used to calculate a comparison signal-time course. We identified putamen circuitry in which the signal aberrance (poor correlation with the comparison signal time course) was predicted by the dopamine theory, being greater in patients than controls; correlating positively with delusion scores; and correlating negatively with antipsychotic-equivalent dosage. In Granger causality analysis, patients showed a compromised contribution of the cortical salience network to the putamen and compromised contribution of the putamen to the default mode network. Results were corrected for multiple comparisons at the cluster level with primary voxel-wise threshold p < 0.005 for the salience network contribution, but liberal primary threshold p < 0.05 was used in other group comparisons. If replicated in larger studies, these findings may help unify and extend current hypotheses on dopaminergic dysfunction, salience processing and pathogenesis of delusions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Comparison of connectivity analyses for resting state EEG data

    NASA Astrophysics Data System (ADS)

    Olejarczyk, Elzbieta; Marzetti, Laura; Pizzella, Vittorio; Zappasodi, Filippo

    2017-06-01

    Objective. In the present work, a nonlinear measure (transfer entropy, TE) was used in a multivariate approach for the analysis of effective connectivity in high density resting state EEG data in eyes open and eyes closed. Advantages of the multivariate approach in comparison to the bivariate one were tested. Moreover, the multivariate TE was compared to an effective linear measure, i.e. directed transfer function (DTF). Finally, the existence of a relationship between the information transfer and the level of brain synchronization as measured by phase synchronization value (PLV) was investigated. Approach. The comparison between the connectivity measures, i.e. bivariate versus multivariate TE, TE versus DTF, TE versus PLV, was performed by means of statistical analysis of indexes based on graph theory. Main results. The multivariate approach is less sensitive to false indirect connections with respect to the bivariate estimates. The multivariate TE differentiated better between eyes closed and eyes open conditions compared to DTF. Moreover, the multivariate TE evidenced non-linear phenomena in information transfer, which are not evidenced by the use of DTF. We also showed that the target of information flow, in particular the frontal region, is an area of greater brain synchronization. Significance. Comparison of different connectivity analysis methods pointed to the advantages of nonlinear methods, and indicated a relationship existing between the flow of information and the level of synchronization of the brain.

  9. Physical validation of a patient-specific contact finite element model of the ankle.

    PubMed

    Anderson, Donald D; Goldsworthy, Jane K; Li, Wendy; James Rudert, M; Tochigi, Yuki; Brown, Thomas D

    2007-01-01

    A validation study was conducted to determine the extent to which computational ankle contact finite element (FE) results agreed with experimentally measured tibio-talar contact stress. Two cadaver ankles were loaded in separate test sessions, during which ankle contact stresses were measured with a high-resolution (Tekscan) pressure sensor. Corresponding contact FE analyses were subsequently performed for comparison. The agreement was good between FE-computed and experimentally measured mean (3.2% discrepancy for one ankle, 19.3% for the other) and maximum (1.5% and 6.2%) contact stress, as well as for contact area (1.7% and 14.9%). There was also excellent agreement between histograms of fractional areas of cartilage experiencing specific ranges of contact stress. Finally, point-by-point comparisons between the computed and measured contact stress distributions over the articular surface showed substantial agreement, with correlation coefficients of 90% for one ankle and 86% for the other. In the past, general qualitative, but little direct quantitative agreement has been demonstrated with articular joint contact FE models. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces (e.g., those from an intact versus those with residual intra-articular fracture incongruity).

  10. Frontal crashworthiness characterisation of a vehicle segment using curve comparison metrics.

    PubMed

    Abellán-López, D; Sánchez-Lozano, M; Martínez-Sáez, L

    2018-08-01

    The objective of this work is to propose a methodology for the characterization of the collision behaviour and crashworthiness of a segment of vehicles, by selecting the vehicle that best represents that group. It would be useful in the development of deformable barriers, to be used in crash tests intended to study vehicle compatibility, as well as for the definition of the representative standard pulses used in numerical simulations or component testing. The characterisation and selection of representative vehicles is based on the objective comparison of the occupant compartment acceleration and barrier force pulses, obtained during crash tests, by using appropriate comparison metrics. This method is complemented with another one, based exclusively on the comparison of a few characteristic parameters of crash behaviour obtained from the previous curves. The method has been applied to different vehicle groups, using test data from a sample of vehicles. During this application, the performance of several metrics usually employed in the validation of simulation models have been analysed, and the most efficient ones have been selected for the task. The methodology finally defined is useful for vehicle segment characterization, taken into account aspects of crash behaviour related to the shape of the curves, difficult to represent by simple numerical parameters, and it may be tuned in future works when applied to larger and different samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Comparisons of neutrino event generators from an oscillation-experiment perspective

    NASA Astrophysics Data System (ADS)

    Mayer, Nathan

    2015-05-01

    Monte Carlo generators are crucial to the analysis of high energy physics data, ideally giving a baseline comparison between the state-of-art theoretical models and experimental data. Presented here is a comparison between three of final state distributions from the GENIE, Neut, NUANCE, and NuWro neutrino Monte Carlo event generators. The final state distributions chosen for comparison are: the electromagnetic energy fraction in neutral current interactions, the energy of the leading π0 vs. the scattering angle for neutral current interactions, and the muon energy vs. scattering angle of νµ charged current interactions.

  12. KEY COMPARISON: Final Report on EUROMET.T-K3: Regional key comparison of the realisations of the ITS-90 from 83.8058 K to 692.677 K

    NASA Astrophysics Data System (ADS)

    Renaot, E.; Hermier, Y.; Valin, M.; Bonnier, G.

    2007-01-01

    This report presents the results of the EUROMET regional key comparison corresponding to CCT-K3 and covering the temperature range from 83.8058 K (triple point of Ar) to 692.77 K (freezing point of Zn). The comparison involved the six NMIs previously involved in CCT-K3 (BNM-INM/CNAM, SMU, IMGC, NMi-VSL, NPL, PTB) and 18 European national laboratories. The comparison was divided into five different loops coordinated by a co-pilot chosen among the laboratories having participated in the CCT-K3 comparison. BNM-INM/CNAM played the role of pilot in establishing the link between the five loops. In each loop, an artefact in the form of a standard platinum resistance thermometer (SPRT) was circulated among the participant laboratories. In order to have sufficient information about the possible drift of the SPRTs, the co-pilots have performed a calibration over the full temperature range at the beginning and at the end of the loop. Each participant laboratory carried out the measurements in agreement with the protocol. After initial measurements of R(tpw) and successful annealing treatment, each calibration consisted of three measurements of R(t) at each fixed point, in separate realizations. Each measurement was followed by a measurement of R(tpw). The order of fixed points was Zn, Sn, In, Ga, Hg, Ar, but if a fixed point was not available, it was omitted. Values of W(t), and their average value, were calculated. The results were reported to the co-pilot and BNM-INM/CNAM, with uncertainty budgets and other specified data. The results of the comparison were analysed by BNM-INM/CNAM. For the sake of clarity, the results are firstly presented loop by loop. In a second step a EUROMET Reference Value (ERV) taking into account the whole comparison was defined. In order to calculate this ERV advantage was taken of the presence of BNM-INM/CNAM in the five loops; the differences between each laboratory's results and BNM-INM's were considered. The participant laboratories decided during a Workshop organized by the pilot in Vienna in April 2005 to use as ERV the weighted mean rather than the simple mean. The differences (TLab - TERV) are presented with the associated uncertainties. Given that the protocol of the comparison contains a detailed description of how the uncertainties are to be calculated, the uncertainty budgets established by the participants seem consistent or, at least, homogeneous. The degrees of equivalence between the participating laboratories (in the same loop or in different loops) are given with their associated uncertainty. Finally, a method for establishing the bilateral equivalence between the participants in CCT-K3 and in EUROMET'T-K3 is proposed. It is recommend to use a group of 'linking laboratories' composed by the pilot and the co-pilots in order to link EUROMET.T-K3 to CCT-K3. The hypothesis is that the mean temperature of the pilot and co-pilot laboratories is the same in EUROMET.T-K3 as it was in CCT-K3. A specific analysis of the pilot's and co-pilot's results shows that even when the results given by one or several members of the 'linking laboratories' are not positioned in the same place as in EUROMET.T-K3 and CCT-K3 the mean calculated for the group is really reproducible. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Final report on COOMET.AUV.A-S1: Technical report on supplementary comparison 'Comparison of national standards of the sound pressure unit in air through calibration of working reference microphones'

    NASA Astrophysics Data System (ADS)

    Pozdeeva, Valentina; Chalyy, Vladimir

    2014-01-01

    The supplementary comparison COOMET.AUV.A-S1 for secondary calibration methods using WS1 and WS2 measurement microphones was carried out from 2009 to 2010. The results were submitted to and approved by CCAUV in April 2014. Four National Metrology Institutes took part in this comparison and are as follows: BelGIM (Belarus), VNIIFTRI (Russia), SMU (Slovakia) and DP NDI 'Sistema' (Ukraine). Three of the above NMIs (VNIIFTRI, SMU and DP NDI 'Sistema') had earlier participated in COOMET key comparisons and one NMI (VNIIFTRI) had also participated in CCAUV key comparisons. The Comparison Reference Values were calculated as the weighted mean values from results obtained by three institutes. The comparison results show agreement for all participants in the frequency range from 20 Hz to 12.5 kHz for WS1 microphones, and in the frequency range from 20 Hz to 16 kHz for WS2 microphones. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. KEY COMPARISON: Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Kurupakorn, C.; Fletcher, N.; Stock, M.

    2010-01-01

    This report describes the results obtained from a NIMT (Thailand)-BIPM bilateral comparison of 10 kΩ resistance standards in 2009. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMIT and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was smaller than the uncertainty arising from the calibrations. The mean difference between the NIMT and the BIPM calibrations was found to be significantly larger than the expanded uncertainty (k = 2) of the comparison. However, this exercise allowed previously undetected sources of errors to be detected in the NIMT facility. A new bilateral comparison can be organized as soon as these problems are fixed. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. Health benefit assessment of pharmaceuticals: An international comparison of decisions from Germany, England, Scotland and Australia.

    PubMed

    Fischer, Katharina Elisabeth; Heisser, Thomas; Stargardt, Tom

    2016-10-01

    Little is known on the performance of the newly introduced health benefit assessment process, AMNOG, in Germany compared to other health technology assessment agencies. We analysed whether decisions of the German Federal Joint Committee (FJC) deviate from decisions of the UK National Institute for Health and Care Excellence (NICE), the Scottish Medicines Consortium (SMC) and the Australian Pharmaceutical Benefits Advisory Committee (PBAC). We analysed decisions made for comparable patient subgroups by the four agencies between 2011 and 2014. First, decisions were compared (a) by their final outcome, i.e. whether a health benefit was identified, and (b) by the agencies' judgement on comparative effectiveness. Subsequently, we partially explored reasons for differences between HTA agencies. From the 192 FJC decisions, we identified 55 that overlapped with NICE, 166 with SMC and 119 with PBAC. FJC agreed with NICE in 40% in final outcome (Cohen's Kappa=-0.13). Similar results were obtained for FJC and SMC (47.6%, kappa=0.03) and FJC and PBAC (48.7%, kappa=0.07). Agreement increased when comparing judgements based on comparative effectiveness only. However, the FJC's final decision was positive only in 43.6%, 39.2% and 44.5% of the patient subgroups, as opposed to 74.5% (NICE), 68.7% (SMC), and 68.9% (PBAC), respectively. We show that the FJC - an agency relatively new in structurally assessing the health benefit of pharmaceuticals - deviates considerably in decisions compared to other HTA agencies. Our study also reveals that the FJC tends to appraise stricter than NICE. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  16. Cost-Effectiveness of High Dose Hemodialysis in Comparison to Conventional In-Center Hemodialysis in the Netherlands.

    PubMed

    Beby, Anna Trisia; Cornelis, Tom; Zinck, Raymund; Liu, Frank Xiaoqing

    2016-11-01

    In the Netherlands, the current standard of care for treating patients with end-stage renal disease is three sessions of in-center hemodialysis (conventional ICHD). However, the literature indicates that high dose hemodialysis (high dose HD) may provide better health outcome such as survival and quality of life. The objective of this study was to determine the cost-effectiveness of high dose HD, both in-center and at home, in comparison to conventional ICHD from a Dutch payer's perspective over a 5 year period. Additionally, the cost-effectiveness of conventional HD at home in comparison to conventional ICHD will be analysed. A Markov model was developed assuming 28-day treatment cycles and was populated with data from Dutch and international renal registries, official tariffs and medical literature. Univariable and probabilistic sensitivity analyses were performed to test the robustness of the results. Using publicly available tariffs from the Dutch Healthcare Authority (Nederlandse Zorgautoriteit) of 2015, doing high dose ICHD instead of conventional ICHD shows an incremental cost-effectiveness ratio (ICER) of €275,747 per quality-adjusted life year (QALY) gained. In contrast, the ICER of high dose HD at home in comparison to conventional ICHD is €3248 per gained QALY. The final analysis shows that conventional HD at home is less costly per patient (-€3063) than conventional ICHD and results in health benefit improvement (+0.249 QALYs), and is therefore regarded as cost saving. Treating dialysis patients with conventional HD at home shows to be cost saving in comparison to conventional ICHD. However, the magnitude of clinical benefit of high dose HD at home is over two times greater than the clinical benefit of conventional HD at home. According to our analysis, from a payer's perspective, high dose HD should be offered as a home therapy to obtain its clinical benefits in a cost-effective manner. Future research should consider our findings alongside societal factors, such as patient preference, monitoring cost for the home patient, productivity loss and capacity. Baxter BV, The Netherlands.

  17. Comparison of Numerical Analyses with a Static Load Test of a Continuous Flight Auger Pile

    NASA Astrophysics Data System (ADS)

    Hoľko, Michal; Stacho, Jakub

    2014-12-01

    The article deals with numerical analyses of a Continuous Flight Auger (CFA) pile. The analyses include a comparison of calculated and measured load-settlement curves as well as a comparison of the load distribution over a pile's length. The numerical analyses were executed using two types of software, i.e., Ansys and Plaxis, which are based on FEM calculations. Both types of software are different from each other in the way they create numerical models, model the interface between the pile and soil, and use constitutive material models. The analyses have been prepared in the form of a parametric study, where the method of modelling the interface and the material models of the soil are compared and analysed. Our analyses show that both types of software permit the modelling of pile foundations. The Plaxis software uses advanced material models as well as the modelling of the impact of groundwater or overconsolidation. The load-settlement curve calculated using Plaxis is equal to the results of a static load test with a more than 95 % degree of accuracy. In comparison, the load-settlement curve calculated using Ansys allows for the obtaining of only an approximate estimate, but the software allows for the common modelling of large structure systems together with a foundation system.

  18. A geometric morphometrics comparative analysis of Neandertal humeri (epiphyses-fused) from the El Sidrón cave site (Asturias, Spain).

    PubMed

    Rosas, Antonio; Pérez-Criado, Laura; Bastir, Markus; Estalrrich, Almudena; Huguet, Rosa; García-Tabernero, Antonio; Pastor, Juan Francisco; de la Rasilla, Marco

    2015-05-01

    A new collection of 49,000 year old Neandertal fossil humeri from the El Sidrón cave site (Asturias, Spain) is presented. A total of 49 humeral remains were recovered, representing 10 left and 8 right humeri from adults, adolescents, and a juvenile (not included in the analyses). 3D geometric morphometric (GM) methods as well as classic anthropological variables were employed to conduct a broad comparative analysis by means of mean centroid size and shape comparisons, principal components analysis, and cluster studies. Due to the fragmentary nature of the fossils, comparisons were organized in independent analyses according to different humeral portions: distal epiphysis, diaphysis, proximal epiphysis, and the complete humerus. From a multivariate viewpoint, 3D-GM analyses revealed major differences among taxonomic groups, supporting the value of the humerus in systematic classification. Notably, the Australopithecus anamensis (KP-271) and Homo ergaster Nariokotome (KNM-WT 15000) distal humerus consistently clusters close to those of modern humans, which may imply a primitive condition for Homo sapiens morphology. Australopithecus specimens show a high degree of dispersion in the morphospace. The El Sidrón sample perfectly fits into the classic Neandertal pattern, previously described as having a relatively wide olecranon fossa, as well as thin lateral and medial distodorsal pillars. These characteristics were also typical of the Sima de los Huesos (Atapuerca) sample, African mid-Pleistocene Bodo specimen, and Lower Pleistocene TD6-Atapuerca remains and may be considered as a derived state. Finally, we hypothesize that most of the features thought to be different between Neandertals and modern humans might be associated with structural differences in the pectoral girdle and shoulder joint. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Final report on key comparison CCAUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Avison, Janine; Barham, Richard

    2014-01-01

    This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report on the EURAMET.M.FF-K4.2.2014 volume comparison at 100 μL—calibration of micropipettes

    NASA Astrophysics Data System (ADS)

    Batista, Elsa; Matus, Michael; Metaxiotou, Zoe; Tudor, Maria; Lenard, Elzbieta; Buker, Oliver; Wennergren, Per; Piluri, Erinda; Miteva, Mariana; Vicarova, Martina; Vospĕlová, Alena; Turnsek, Urska; Micic, Ljiljana; Grue, Lise-Lote; Mihailovic, Mirjana; Sarevska, Anastazija

    2017-01-01

    During the EURAMET TC-F meeting of 2014 and following the finalization of CCM.FF-K4.2.2011 comparison, it was agreed to start a Regional Key Comparison (KC) on volume measurements using two 100 μL micropipettes (piston pipettes) allowing the participating laboratories to assess the agreement of their results and uncertainties. Two 100 μL micropipettes were tested by 15 participants. One participant was not a member or associate member of the BIPM and was be removed from this report. The comparison started in July 2015 and ended in March 2016. The Volume and Flow Laboratory of the Portuguese Institute for Quality (IPQ) was the pilot laboratory and performed the initial and final measurements of the micropipettes. The micropipettes showed a stable volume during the whole comparison, which was confirmed by the results from the pilot laboratory. The original results of all participant NMIs were corrected to the standard atmospheric pressure in order to compare results under the same calibration conditions, and the contribution of the 'process-related handling contribution' was added to the uncertainty budget of each participant. In general the declared CMCs are in accordance with the KCDB. For the micropipette 354828Z, two laboratories had inconsistent results. For micropipette 354853Z, three laboratories had inconsistent results. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. The nonconforming virtual element method for eigenvalue problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gardini, Francesca; Manzini, Gianmarco; Vacca, Giuseppe

    We analyse the nonconforming Virtual Element Method (VEM) for the approximation of elliptic eigenvalue problems. The nonconforming VEM allow to treat in the same formulation the two- and three-dimensional case.We present two possible formulations of the discrete problem, derived respectively by the nonstabilized and stabilized approximation of the L 2-inner product, and we study the convergence properties of the corresponding discrete eigenvalue problems. The proposed schemes provide a correct approximation of the spectrum and we prove optimal-order error estimates for the eigenfunctions and the usual double order of convergence of the eigenvalues. Finally we show a large set of numericalmore » tests supporting the theoretical results, including a comparison with the conforming Virtual Element choice.« less

  2. Report on the bilateral comparison between BIM (Bulgaria) and VSL (The Netherlands)

    NASA Astrophysics Data System (ADS)

    Dekker, Paul; Kunova, Angela; Dierikx, Erik

    2017-01-01

    A bilateral comparison has been organized between VSL, The Netherlands and BIM, Bulgaria in the field of spectral regular transmittance measurements. This comparison is registered as EURAMET project nr. 1073 and EURAMET.PR-K6.2 in the BIPM key comparison database. The aim of the comparison is to demonstrate the improvement of calibration measurement capabilities of BIM in this working field. If this comparison is successful, i.e. the results support the claimed improvement in uncertainties, the improved CMC's for BIM will be included in Appendix C of the CIPM mutual recognition arrangement (MRA). The results of this comparison are linked to key comparison CCPR K6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Final report on the key comparison CCM.P-K4.2012 in absolute pressure from 1 Pa to 10 kPa

    NASA Astrophysics Data System (ADS)

    Ricker, Jacob; Hendricks, Jay; Bock, Thomas; Dominik, Pražák; Kobata, Tokihiko; Torres, Jorge; Sadkovskaya, Irina

    2017-01-01

    The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  5. KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Final report on key comparison COOMET.QM-K36 (Project COOMET 540/UA/11) 'Electrolytic Conductivity 0,5 S/m'

    NASA Astrophysics Data System (ADS)

    Gavrilkin, V.; Prokopenko, L.; Bakovec, N.; Zolotorevich, E.; Suvorov, V.; Ovchinnikov, Yu; Pilishvili, T.; Buleishvili, M.; Zhasanbaeva, B.; Aytzhatova, G.; Ticona, G.; Vyskocil, L.

    2015-01-01

    The COOMET.QM-K36 key comparison 'Electrolytic conductivity: 0.5 S/m' is a comparison in the field of electrolytic conductivity measurements conducted by COOMET and carried out in 2012. It used a solution of KCl in water and the results are connected to those of the CCQM key comparison CCQM-K36.a through common participation of VNIIFTRI (Russia), SMU (Slovakia) and Ukrmetrteststandart (Ukraine). The purpose of this key comparison was to establish the equivalence of measurements of electrolytic conductivity performed at the National Metrology Institutes of COOMET member states for the value of 0.5 S/m. The results can be used to support the CMCs claims over the range of 0.1 S/m to 1.3 S/m. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on the Seventh International Comparison of Absolute Gravimeters (ICAG 2005)

    USGS Publications Warehouse

    Jiang, Z.; Francis, O.; Vitushkin, L.; Palinkas, V.; Germak, A.; Becker, M.; D'Agostino, G.; Amalvict, M.; Bayer, R.; Bilker-Koivula, M.; Desogus, S.; Faller, J.; Falk, R.; Hinderer, J.; Gagnon, C.; Jakob, T.; Kalish, E.; Kostelecky, J.; Lee, C.; Liard, J.; Lokshyn, Y.; Luck, B.; Makinen, J.; Mizushima, S.; Le, Moigne N.; Origlia, C.; Pujol, E.R.; Richard, P.; Robertsson, L.; Ruess, D.; Schmerge, D.; Stus, Y.; Svitlov, S.; Thies, S.; Ullrich, C.; Van Camp, M.; Vitushkin, A.; Ji, W.; Wilmes, H.

    2011-01-01

    The Bureau International des Poids et Mesures (BIPM), S??vres, France, hosted the 7th International Comparison of Absolute Gravimeters (ICAG) and the associated Relative Gravity Campaign (RGC) from August to September 2005. ICAG 2005 was prepared and performed as a metrological pilot study, which aimed: To determine the gravity comparison reference values; To determine the offsets of the absolute gravimeters; and As a pilot study to accumulate experience for the CIPM Key Comparisons. This document presents a complete and extensive review of the technical protocol and data processing procedures. The 1st ICAG-RGC comparison was held at the BIPM in 1980-1981 and since then meetings have been organized every 4 years. In this paper, we present an overview of how the meeting was organized, the conditions of BIPM gravimetric sites, technical specifications, data processing strategy and an analysis of the final results. This 7th ICAG final report supersedes all previously published reports. Readings were obtained from participating instruments, 19 absolute gravimeters and 15 relative gravimeters. Precise levelling measurements were carried out and all measurements were performed on the BIPM micro-gravity network which was specifically designed for the comparison. ?? 2011 BIPM & IOP Publishing Ltd.

  10. Final report on SIM Regional Key Comparison SIM.L-K1.2007: Calibration of gauge blocks by optical interferometry

    NASA Astrophysics Data System (ADS)

    Colín, C.; Viliesid, M.; Chaudhary, K. P.; Decker, J.; Dvorácek, F.; Franca, R.; Ilieff, S.; Rodríguez, J.; Stoup, J.

    2012-01-01

    This Key Comparison of gauge blocks (GB) calibration by optical interferometry was carried out to support this Calibration and Measurement Capability (CMC) of the National Measurement Institutes (NMI) from the SIM Region for this specific service and for those that rely on this kind of technique as required by the Mutual Recognition Arrangement (MRA). It provides evidence of the participant's technical competence and supports the uncertainties they state in their CMC. It is a Regional Key Comparison and should be linked to the upper level corresponding comparison CCL-K1. The comparison had nine participants, five from the SIM Region—NRC-CNRC, Canada; NIST, USA; CENAM, Mexico; INMETRO, Brazil; and INTI, Argentina— and four from other regions—CMI, Czech Rep.; CEM, Spain; NPLI, India; and NMISA South Africa. It included the circulation of fourteen GB—seven steel GB and seven ceramic GB. The circulation of the artifacts started on 2007-11-01 and ended on 2010-04-25. Some additional time was required to publish the results as the same artifacts were used thereafter for comparison SIM.L-S6, Calibration of GB by mechanical comparison, and the results could not be disclosed until the participants of the second circulation loop had sent their results. The final report of this comparison was sent out for review in May 2012 and the final version was approved in August 2012. The behavior of the artifacts throughout the circulation was good and therefore the results obtained were judged technically valid. The reference value was taken as arithmetic mean of the largest subset of consistent results. Most of participates obtained results in good agreement with the reference values with a few exceptions mentioned in the report. The corresponding NMIs are responsible for identifying the causes and taking corrective action. This makes the present comparison exercise valid to support the CMC claims of the participants in GB calibration by optical interferometry. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Final report on key comparison CCQM-K81: Chloramphenicol in pig muscle

    NASA Astrophysics Data System (ADS)

    Polzer, Joachim; Henrion, Andre; Gowik, Petra

    2013-01-01

    Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K81 'Chloramphenicol in pig muscle', was coordinated by BVL and PTB in 2009/2010. Six NMIs/DIs participated in this comparison. Chloramphenicol (CAP) is an effective broad-spectrum antibiotic which can in principle be used for the treatment of humans and animals. Its use for the treatment of food-producing animals is, however, forbidden worldwide in many countries due to potential severe side effects. The key comparison was the follow-up to the successful pilot study 'CCQM-P90: chloramphenicol in milk'. With this key comparison it was intended to demonstrate the capability of NMIs/DIs to analyse traces of CAP in food at concentration levels resulting from legal requirements for food control. Additionally, the quality of this kind of analysis with respect to compliance with legal requirements for food control methods and the international comparability of measurements should be evaluated in general. The study was classified as a 'track C' study (studies in emerging areas of global interest). For the study incurred lyophilised pig muscle material containing CAP (at a mass-fraction level around the maximum allowable level for import for a number of countries) has been produced as a candidate reference material by BVL and IRMM (Institute for Reference Materials and Measurements, JRC of the European Commission). Animal treatment and slaughtering of the animal to gain incurred muscle material as well as pre-testing of the CAP content was done at the BVL. The IRMM did further processing of the material and testing of homogeneity and stability. Participants were invited to assign the mass fraction of free CAP in the comparison sample. CCQM-K81 demonstrated successfully the capability of the participating laboratories to assign chloramphenicol values in tissue down to residue levels of around 0.3 ng/g (referring to the analyte content in reconstituted muscle material). Although very different sample preparation techniques (different pre-treatments, defattening steps, cartridges, solvents) as well as different analytical techniques (LC-MSMS, GC-MS, different instruments, columns, eluents) were applied to detect chloramphenicol at a very low concentration level, a KCRV of 0.267 ng/g with a satisfying expanded uncertainty of 17.4% was ascertained. Two of the reported results were not eligible to be used in establishing the KCRV; anyhow the KCRV as estimated from just the eligible results agrees very well with the additional results. With respect to legal requirements for quantitative methods for residue control in food the key comparison results prove the capabilities of the laboratories to fulfil these settings with highest precision and to provide calibration and measurement services to residue control laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. On the comparison between MASS and generalized-SCIDAR techniques

    NASA Astrophysics Data System (ADS)

    Masciadri, E.; Lombardi, G.; Lascaux, F.

    2014-02-01

    The Multi-Aperture Scintillation Sensor (MASS) and the Generalized-Scintillation Detection and Ranging (Generalized-SCIDAR) are two instruments conceived to measure the optical turbulence vertical distribution on the whole troposphere and low stratosphere (˜20 km) widely used in the astronomical context. In this paper, we perform a detailed analysis/comparison of measurements provided by the two instruments and taken during the extended site testing campaign carried out in 2007 at Cerro Paranal and promoted by the European Southern Observatory. The main and final goal of the study is to provide a detailed estimation of the measurements reliability, i.e. dispersion of turbulence measurements done by the two instruments at different heights above the ground. This information is directly related to our ability in estimating the absolute value of the turbulence stratification. To better analyse the uncertainties between the MASS and the Generalized-SCIDAR we took advantage of the availability of measurements taken during the same campaign by a third independent instrument called Differential Image Motion Monitor (DIMM) measuring the integrated turbulence extended on the whole 20 km. Such a cross-check comparison permitted us to define the reliability of the instruments and their measurements, their limits and the contexts in which their use can present some risk.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Some of the major technical questions associated with the burial of radioactive high-level wastes in geologic formations are related to the thermal environments generated by the waste and the impact of this dissipated heat on the surrounding environment. The design of a high level waste storage facility must be such that the temperature variations that occur do not adversely affect operating personnel and equipment. The objective of this investigation was to assist OWI by determining the thermal environment that would be experienced by personnel and equipment in a waste storage facility in salt. Particular emphasis was placed on determining themore » maximum floor and air temperatures with and without ventilation in the first 30 years after waste emplacement. The assumed facility design differs somewhat from those previously analyzed and reported, but many of the previous parametric surveys are useful for comparison. In this investigation a number of 2-dimensional and 3-dimensional simulations of the heat flow in a repository have been performed on the HEATING5 and TRUMP heat transfer codes. The representative repository constructs used in the simulations are described, as well as the computational models and computer codes. Results of the simulations are presented and discussed. Comparisons are made between the recent results and those from previous analyses. Finally, a summary of study limitations, comparisons, and conclusions is given.« less

  14. Final report on comparison of hydraulic pressure balance effective area determination in the range up to 80 MPa

    NASA Astrophysics Data System (ADS)

    Grgec Bermanec, L.; Pantic, D.; Ramac, B.

    2018-01-01

    Bilateral comparison was organized between the laboratory for process measurement of the Croatian Metrology Institute (HMI/FSB-LPM) and the pressure laboratory of the Directorate of Measures and Precious Metals of the Republic of Serbia (DMDM). Laboratory for process measurement of HMI acted as the pilot laboratory. The aim of the comparison was to evaluate the degree of equivalence in the determination of effective area and elastic distortion coefficient, considering respective uncertainties of the two laboratories. Measurements were done on the pressure balance in gauge mode, with oil as transmitting medium, in the gauge pressure range 10–80 MPa. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    NASA Astrophysics Data System (ADS)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. An etiological model of disordered eating behaviors among Brazilian women.

    PubMed

    de Carvalho, Pedro Henrique Berbert; Alvarenga, Marle Dos Santos; Ferreira, Maria Elisa Caputo

    2017-09-01

    The Tripartite Influence Model posits that parents, peers and media influences mediated by internalization and appearance social comparison are predictors of body dissatisfaction, a key risk factor for eating disorders. However, the Tripartite Influence Model has not been tested in Brazil where the people are known to have high levels of body image and appearance concerns. This study aimed to test an adapted Tripartite Influence Model of body dissatisfaction and disordered eating behaviors among Brazilian women. A sample of 741 undergraduate students (M age  = 23.55 years, SD = 4.09) completed measures of sociocultural influences, internalization of body ideal, social appearance comparison, body dissatisfaction, muscularity dissatisfaction, disordered eating and body change behaviors. Structural equation modeling analyses indicated that the proposed etiological model for Brazilian women has good fit indexes (χ 2 (2064) = 6793.232; p = 0.0001; χ 2 /gl = 3.29; CFI = 0.82; PCFI = 0.79; RMSEA = 0.056 [IC90% = 0.053-0.057]). Parent and media influences were related with both internalization and social comparison, while peer influence with social comparison. A full mediation model was found, with both internalization and social comparison contributing to body dissatisfaction. Finally, body dissatisfaction was associated with disordered eating behaviors. The findings inform the importance of considering cultural aspects that influence body image and eating behaviors, and highlight the validity of the proposed etiological model for Brazilian women, that can be used for research and clinical purposes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Angiosonography in suspicious breast lesions with non-diagnostic FNAC: comparison with power Doppler US.

    PubMed

    Caumo, F; Carbognin, G; Casarin, A; Pinali, L; Vasori, S; D'Onofrio, M; Pozzi Mucelli, R

    2006-02-01

    The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC). Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34. The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour. Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesions.

  18. Comparison of extraction techniques of robenidine from poultry feed samples.

    PubMed

    Wilga, Joanna; Wasik, Agata Kot-; Namieśnik, Jacek

    2007-10-31

    In this paper, effectiveness of six different commonly applied extraction techniques for the determination of robenidine in poultry feed has been compared. The sample preparation techniques included shaking, Soxhlet, Soxtec, ultrasonically assisted extraction, microwave - assisted extraction and accelerated solvent extraction. Comparison of these techniques was done with respect to the recovery extraction, temperature and time, reproducibility and solvent consumption. Every single extract was subjected to clean - up using aluminium oxide column (Pasteur pipette filled with 1g of aluminium oxide), from which robenidine was eluted with 10ml of methanol. The eluate from the clean-up column was collected in a volumetric flask, and finally it was analysed by HPLC-DAD-MS. In general, all extraction techniques were capable of isolating of robenidine from poultry feed, but the recovery obtained using modern extraction techniques was higher than that obtained using conventional techniques. In particular, accelerated solvent extraction was more superior to other techniques, which highlights the advantages of this sample preparation technique. However, in routine analysis, shaking and ultrasonically assisted extraction is still the preferred method for the solution of robenidine and other coccidiostatics.

  19. International comparison of activity measurements of a solution of 238Pu

    NASA Astrophysics Data System (ADS)

    Ratel, G.; Michotte, C.

    2018-01-01

    This report concerns an international comparison of measurements of a solution of 238Pu that was carried out by 12 participants in 2001. The report includes the degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Comparison APMP.QM-S2.1: oxygen in nitrogen at atmospheric level

    NASA Astrophysics Data System (ADS)

    Kim, B. M.; Kim, K.; Jung, J.; Oh, S.; Hui, L.; Li, H.; Keat, T. B.; Ann, C. H.

    2016-01-01

    This document describes results of the bilateral comparison of an oxygen in nitrogen gas mixture. The nominal amount-of-substance fraction was 0.2 mol/mol oxygen in nitrogen Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Final report of APMP.QM-K46 ammonia in nitrogen at 30 μmol/mol level

    NASA Astrophysics Data System (ADS)

    Uehara, Shinji; Qiao, Han; Shimosaka, Takuya

    2017-01-01

    This report describes the results for a bilateral comparison of ammonia in nitrogen gas mixture. The nominal amount-of-substance fraction was 30 μmol/mol. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Taiwan industrial cooperation program technology transfer for low-level radioactive waste final disposal - phase I.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knowlton, Robert G.; Cochran, John Russell; Arnold, Bill Walter

    2007-01-01

    Sandia National Laboratories and the Institute of Nuclear Energy Research, Taiwan have collaborated in a technology transfer program related to low-level radioactive waste (LLW) disposal in Taiwan. Phase I of this program included regulatory analysis of LLW final disposal, development of LLW disposal performance assessment capabilities, and preliminary performance assessments of two potential disposal sites. Performance objectives were based on regulations in Taiwan and comparisons to those in the United States. Probabilistic performance assessment models were constructed based on limited site data using software including GoldSim, BLT-MS, FEHM, and HELP. These software codes provided the probabilistic framework, container degradation, waste-formmore » leaching, groundwater flow, radionuclide transport, and cover infiltration simulation capabilities in the performance assessment. Preliminary performance assessment analyses were conducted for a near-surface disposal system and a mined cavern disposal system at two representative sites in Taiwan. Results of example calculations indicate peak simulated concentrations to a receptor within a few hundred years of LLW disposal, primarily from highly soluble, non-sorbing radionuclides.« less

  3. Dalitz plot analysis of the D+→K-π+π+ decay in the FOCUS experiment

    NASA Astrophysics Data System (ADS)

    Link, J. M.; Yager, P. M.; Anjos, J. C.; Bediaga, I.; Castromonte, C.; Machado, A. A.; Magnin, J.; Massafferri, A.; de Miranda, J. M.; Pepe, I. M.; Polycarpo, E.; Dos Reis, A. C.; Carrillo, S.; Casimiro, E.; Cuautle, E.; Sánchez-Hernández, A.; Uribe, C.; Vázquez, F.; Agostino, L.; Cinquini, L.; Cumalat, J. P.; Frisullo, V.; O'Reilly, B.; Segoni, I.; Stenson, K.; Butler, J. N.; Cheung, H. W. K.; Chiodini, G.; Gaines, I.; Garbincius, P. H.; Garren, L. A.; Gottschalk, E.; Kasper, P. H.; Kreymer, A. E.; Kutschke, R.; Wang, M.; Benussi, L.; Bianco, S.; Fabbri, F. L.; Zallo, A.; Reyes, M.; Cawlfield, C.; Kim, D. Y.; Rahimi, A.; Wiss, J.; Gardner, R.; Kryemadhi, A.; Chung, Y. S.; Kang, J. S.; Ko, B. R.; Kwak, J. W.; Lee, K. B.; Cho, K.; Park, H.; Alimonti, G.; Barberis, S.; Boschini, M.; Cerutti, A.; D'Angelo, P.; Dicorato, M.; Dini, P.; Edera, L.; Erba, S.; Inzani, P.; Leveraro, F.; Malvezzi, S.; Menasce, D.; Mezzadri, M.; Moroni, L.; Pedrini, D.; Pontoglio, C.; Prelz, F.; Rovere, M.; Sala, S.; Davenport, T. F.; Arena, V.; Boca, G.; Bonomi, G.; Gianini, G.; Liguori, G.; Lopes Pegna, D.; Merlo, M. M.; Pantea, D.; Ratti, S. P.; Riccardi, C.; Vitulo, P.; Göbel, C.; Otalora, J.; Hernandez, H.; Lopez, A. M.; Mendez, H.; Paris, A.; Quinones, J.; Ramirez, J. E.; Zhang, Y.; Wilson, J. R.; Handler, T.; Mitchell, R.; Engh, D.; Hosack, M.; Johns, W. E.; Luiggi, E.; Nehring, M.; Sheldon, P. D.; Vaandering, E. W.; Webster, M.; Sheaff, M.; Pennington, M. R.; Focus Collaboration

    2007-09-01

    Using data collected by the high-energy photoproduction experiment FOCUS at Fermilab we performed a Dalitz plot analysis of the Cabibbo favored decay D+ →K-π+π+. This study uses 53653 Dalitz-plot events with a signal fraction of ∼ 97%, and represents the highest statistics, most complete Dalitz plot analysis for this channel. Results are presented and discussed using two different formalisms. The first is a simple sum of Breit-Wigner functions with freely fitted masses and widths. It is the model traditionally adopted and serves as comparison with the already published analyses. The second uses a K-matrix approach for the dominant S-wave, in which the parameters are fixed by first fitting Kπ scattering data and continued to threshold by Chiral Perturbation Theory. We show that the Dalitz plot distribution for this decay is consistent with the assumption of two-body dominance of the final state interactions and the description of these interactions is in agreement with other data on the Kπ final state.

  4. A quantitative dynamic systems model of health-related quality of life among older adults

    PubMed Central

    Roppolo, Mattia; Kunnen, E Saskia; van Geert, Paul L; Mulasso, Anna; Rabaglietti, Emanuela

    2015-01-01

    Health-related quality of life (HRQOL) is a person-centered concept. The analysis of HRQOL is highly relevant in the aged population, which is generally suffering from health decline. Starting from a conceptual dynamic systems model that describes the development of HRQOL in individuals over time, this study aims to develop and test a quantitative dynamic systems model, in order to reveal the possible dynamic trends of HRQOL among older adults. The model is tested in different ways: first, with a calibration procedure to test whether the model produces theoretically plausible results, and second, with a preliminary validation procedure using empirical data of 194 older adults. This first validation tested the prediction that given a particular starting point (first empirical data point), the model will generate dynamic trajectories that lead to the observed endpoint (second empirical data point). The analyses reveal that the quantitative model produces theoretically plausible trajectories, thus providing support for the calibration procedure. Furthermore, the analyses of validation show a good fit between empirical and simulated data. In fact, no differences were found in the comparison between empirical and simulated final data for the same subgroup of participants, whereas the comparison between different subgroups of people resulted in significant differences. These data provide an initial basis of evidence for the dynamic nature of HRQOL during the aging process. Therefore, these data may give new theoretical and applied insights into the study of HRQOL and its development with time in the aging population. PMID:26604722

  5. Final report of the key comparison APMP.QM-K9: APMP comparison on pH measurement of phosphate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Ohata, Masaki; Cherdchu, Chainarong; Tangpaisarnkul, Nongluck

    2011-01-01

    The APMP.QM-K9 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phosphate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan, NMIJ, and the National Institute of Metrology of Thailand, NIMT, in August 2009. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K9, CCQM-K9.1 and CCQM-K9.2. The comparison material was a phosphate buffer of pH around 6.86 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the first APMP key comparison on pH measurement and the third APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004 and APMP.QM-P09 (a phthalate buffer) in 2006. The results can be used further by any participant to support its CMC claim for a phosphate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the temperature(s) used or the full temperature range between 15 °C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. [Differentiation of coding quality in orthopaedics by special, illustration-oriented case group analysis in the G-DRG System 2005].

    PubMed

    Schütz, U; Reichel, H; Dreinhöfer, K

    2007-01-01

    We introduce a grouping system for clinical practice which allows the separation of DRG coding in specific orthopaedic groups based on anatomic regions, operative procedures, therapeutic interventions and morbidity equivalent diagnosis groups. With this, a differentiated aim-oriented analysis of illustrated internal DRG data becomes possible. The group-specific difference of the coding quality between the DRG groups following primary coding by the orthopaedic surgeon and final coding by the medical controlling is analysed. In a consecutive series of 1600 patients parallel documentation and group-specific comparison of the relevant DRG parameters were carried out in every case after primary and final coding. Analysing the group-specific share in the additional CaseMix coding, the group "spine surgery" dominated, closely followed by the groups "arthroplasty" and "surgery due to infection, tumours, diabetes". Altogether, additional cost-weight-relevant coding was necessary most frequently in the latter group (84%), followed by group "spine surgery" (65%). In DRGs representing conservative orthopaedic treatment documented procedures had nearly no influence on the cost weight. The introduced system of case group analysis in internal DRG documentation can lead to the detection of specific problems in primary coding and cost-weight relevant changes of the case mix. As an instrument for internal process control in the orthopaedic field, it can serve as a communicative interface between an economically oriented classification of the hospital performance and a specific problem solution of the medical staff involved in the department management.

  7. Key comparison BIPM.RI(I)-K9 of the absorbed dose to water standards of the PTB, Germany and the BIPM in medium-energy x-rays

    NASA Astrophysics Data System (ADS)

    Burns, D. T.; Kessler, C.; Büermann, L.; Ketelhut, S.

    2018-01-01

    A key comparison has been made between the absorbed dose to water standards of the PTB, Germany and the BIPM in the medium-energy x-ray range. The results show the standards to be in general agreement at the level of the standard uncertainty of the comparison of 9 to 11 parts in 103. The results are combined with those of a EURAMET comparison and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Comparisons of absolute gravimeters (COOMET.M.G-S1)

    NASA Astrophysics Data System (ADS)

    Vinnichenko, Mr Alexander; Germak, Alessandro, Dr

    2017-01-01

    This report describes the results of the RMO supplementary comparison COOMET.M.G-S1 (also known as bilateral comparison COOMET 634/UA/14). The comparison measurements between the two participants NSC 'IM' (pilot laboratory) and INRIM were started in December 2015 and finished in January 2016. Participants of comparisons were conducted at their national standards the measurements of the free fall acceleration in gravimetric point laboratory of absolute gravimetry of INRIM named INRiM.2. Absolute measurements of gravimetric acceleration were conducted by ballistic gravimeters. The agreement between the two participants is good. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. KEY COMPARISON: BIPM comparison BIPM.RI(II)-K1.Cu-64 of the activity measurements of the radionuclide 64Cu

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Courte, S.; Ratel, G.; Kossert, K.; Nähle, O. J.

    2009-01-01

    In 2009, the Physikalisch-Technische Bundesanstalt (PTB), Germany, submitted a sample of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The value of the activity submitted was about 9.3 MBq. The result of this new comparison has been approved for publication by Section II of the Consultative Committee for Ionizing Radiation (CCRI(II)), comparison identifier BIPM.RI(II)-K1.Cu-64. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. Final report on SIM.T-S5: comparison of the calibration of 100 Ω platinum resistance thermometers

    NASA Astrophysics Data System (ADS)

    del Campo, D.; García, S.; Velasquez, A.; Medrano, J. A.; Solano, A.; Torres, H. E.

    2015-01-01

    An International Comparison on industrial Platinum Resistance Thermometers (PRTs) among the National Metrology Institutes (NMIs) of Spain, Panama, Honduras, El Salvador, Costa Rica and Nicaragua began in 2013 and was successfully completed in 2014. Two PRTs were circulated (hand carried) and compared in the range from -38.8 °C up to 250 °C. The Centro Español de Metrología (Spanish NMI), CEM, acted as the pilot laboratory providing the reference value of the comparison. The thermometers have shown an acceptable behavior throughout the comparison, therefore the results can be considered valid for comparing the measurement capabilities of the participant laboratories. The equivalence between the participant laboratories in the calibration of platinum resistance thermometers by comparison in the range from -38,8 °C up to 250 °C has been demonstrated in almost all cases. This report presents the results of this comparison and provides detailed information of the measurements performed by the participating laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Report on key comparison COOMET.AUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Dobrowolska, D.; Kosterov, A.

    2016-01-01

    This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the BIM, Bulgaria, and the BIPM, April 2012 to September 2012

    NASA Astrophysics Data System (ADS)

    Sapunova, I.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the BIM (Bulgaria) and the BIPM carried out in 2012. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz and for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 1.1 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral comparison of 100 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 100 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.66 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral comparison of 10 pF capacitance standards (ongoing BIPM key comparison BIPM.EM-K14.a) between the NSAI-NML, Ireland, and the BIPM, March-August 2011

    NASA Astrophysics Data System (ADS)

    Power, O.; Moran, A.; Fletcher, N.; Goebel, R.; Stock, M.

    2015-01-01

    This report gives the result of a bilateral comparison of capacitance between the NSAI-NML (Ireland) and the BIPM carried out in 2011. Two 10 pF travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A—B—A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz for a measuring voltage of 15 V. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.a. The results from the NSAI-NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 2.5 × 10-6. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Power, Oliver

    2017-01-01

    This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of the ongoing BIPM key comparison BIPM.EM-K14.b in which the BIPM is the pilot laboratory. Two 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of 1000 Hz, for a measuring rms voltage of 15 V. The results from the NSAI-NML and the BIPM were found to be in relatively good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of 0.85 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report of CCAUV.V-K3: key comparison in the field of acceleration on the complex charge sensitivity

    NASA Astrophysics Data System (ADS)

    Qiao, Sun; Lifeng, Yang; Bartoli, Claire; Veldman, Ian; Ripper, Gustavo P.; Bruns, Thomas; Rask Licht, Torben; Kolasa, Joanna; Hof, Christian; Silva Pineda, Guillermo; Dickinson, Laurence; Ota, Akihiro; Cheung, Wan Sup; Yankovsky, Alexander; Shan, Cui

    2017-01-01

    This is the final report for CIPM key comparison CCAUV.V-K3 in the area of 'vibration' (quantity of acceleration). The aim of this comparison was to measure the voltage sensitivity of one accelerometer standard set with primary means at 27 frequencies from 0.1 Hz to 40 Hz. Fourteen Metrology Institutes from five RMOs have participated in the comparison with National Institute of Metrology, P.R. China as pilot lab and Laboratoire National de Métrologie et d'Essais and National Metrology Institute of South Africa as co-pilot labs. One quartz-flexure servo accelerometer of single-ended type and a signal conditioner was circulated among the participants. All but one of the participating laboratories provided their calibration results, which were mostly consistent within their declared expanded uncertainties for magnitude results. Only two participants failed to contribute to the KCRV values calculated for five frequencies. For phase shift, three participants could not contribute to the calculation of the KCRV values in a total of sixteen frequencies. This first low-frequency vibration key comparison revealed the current calibration capabilities of the fourteen participants of five RMOs. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on APMP.M.P-S3: Results of the supplementary comparison in gas media in the range 1.77 MPa to 6.8 MPa

    NASA Astrophysics Data System (ADS)

    Owen, N.; Bergoglio, M.

    2013-01-01

    This report provides the results of the supplementary bilateral comparison APMP.M.P-S3 between NMI Australia (NMIA) and INRIM, Italy executed from November 2010 to November 2011. NMIA acted as the pilot laboratory and provided a Ruska G series piston gauge as the transfer standard, with a nominal area 16.8 mm2 requiring a nominal load of 12 kg to balance a pressure of 7.0 MPa. The purpose of this supplementary bilateral comparison was to provide data for linking NMIA to CCM.P-K1.c in the pressure range greater than 4 MPa to extend the range covered by key comparison APMP.M.P-K1c. The original protocol called for the pressure range from 80 kPa to 6.80 MPa. Both participants agreed to limit this comparison range to 1.77 MPa to 6.50 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. MEGALEX: A megastudy of visual and auditory word recognition.

    PubMed

    Ferrand, Ludovic; Méot, Alain; Spinelli, Elsa; New, Boris; Pallier, Christophe; Bonin, Patrick; Dufau, Stéphane; Mathôt, Sebastiaan; Grainger, Jonathan

    2018-06-01

    Using the megastudy approach, we report a new database (MEGALEX) of visual and auditory lexical decision times and accuracy rates for tens of thousands of words. We collected visual lexical decision data for 28,466 French words and the same number of pseudowords, and auditory lexical decision data for 17,876 French words and the same number of pseudowords (synthesized tokens were used for the auditory modality). This constitutes the first large-scale database for auditory lexical decision, and the first database to enable a direct comparison of word recognition in different modalities. Different regression analyses were conducted to illustrate potential ways to exploit this megastudy database. First, we compared the proportions of variance accounted for by five word frequency measures. Second, we conducted item-level regression analyses to examine the relative importance of the lexical variables influencing performance in the different modalities (visual and auditory). Finally, we compared the similarities and differences between the two modalities. All data are freely available on our website ( https://sedufau.shinyapps.io/megalex/ ) and are searchable at www.lexique.org , inside the Open Lexique search engine.

  1. Building integrated business environments: analysing open-source ESB

    NASA Astrophysics Data System (ADS)

    Martínez-Carreras, M. A.; García Jimenez, F. J.; Gómez Skarmeta, A. F.

    2015-05-01

    Integration and interoperability are two concepts that have gained significant prominence in the business field, providing tools which enable enterprise application integration (EAI). In this sense, enterprise service bus (ESB) has played a crucial role as the underpinning technology for creating integrated environments in which companies may connect all their legacy-applications. However, the potential of these technologies remains unknown and some important features are not used to develop suitable business environments. The aim of this paper is to describe and detail the elements for building the next generation of integrated business environments (IBE) and to analyse the features of ESBs as the core of this infrastructure. For this purpose, we evaluate how well-known open-source ESB products fulfil these needs. Moreover, we introduce a scenario in which the collaborative system 'Alfresco' is integrated in the business infrastructure. Finally, we provide a comparison of the different open-source ESBs available for IBE requirements. According to this study, Fuse ESB provides the best results, considering features such as support for a wide variety of standards and specifications, documentation and implementation, security, advanced business trends, ease of integration and performance.

  2. Materials Informatics: Statistical Modeling in Material Science.

    PubMed

    Yosipof, Abraham; Shimanovich, Klimentiy; Senderowitz, Hanoch

    2016-12-01

    Material informatics is engaged with the application of informatic principles to materials science in order to assist in the discovery and development of new materials. Central to the field is the application of data mining techniques and in particular machine learning approaches, often referred to as Quantitative Structure Activity Relationship (QSAR) modeling, to derive predictive models for a variety of materials-related "activities". Such models can accelerate the development of new materials with favorable properties and provide insight into the factors governing these properties. Here we provide a comparison between medicinal chemistry/drug design and materials-related QSAR modeling and highlight the importance of developing new, materials-specific descriptors. We survey some of the most recent QSAR models developed in materials science with focus on energetic materials and on solar cells. Finally we present new examples of material-informatic analyses of solar cells libraries produced from metal oxides using combinatorial material synthesis. Different analyses lead to interesting physical insights as well as to the design of new cells with potentially improved photovoltaic parameters. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Familial covariation of facial emotion recognition and IQ in schizophrenia.

    PubMed

    Andric, Sanja; Maric, Nadja P; Mihaljevic, Marina; Mirjanic, Tijana; van Os, Jim

    2016-12-30

    Alterations in general intellectual ability and social cognition in schizophrenia are core features of the disorder, evident at the illness' onset and persistent throughout its course. However, previous studies examining cognitive alterations in siblings discordant for schizophrenia yielded inconsistent results. Present study aimed to investigate the nature of the association between facial emotion recognition and general IQ by applying genetically sensitive cross-trait cross-sibling design. Participants (total n=158; patients, unaffected siblings, controls) were assessed using the Benton Facial Recognition Test, the Degraded Facial Affect Recognition Task (DFAR) and the Wechsler Adult Intelligence Scale-III. Patients had lower IQ and altered facial emotion recognition in comparison to other groups. Healthy siblings and controls did not significantly differ in IQ and DFAR performance, but siblings exhibited intermediate angry facial expression recognition. Cross-trait within-subject analyses showed significant associations between overall DFAR performance and IQ in all participants. Within-trait cross-sibling analyses found significant associations between patients' and siblings' IQ and overall DFAR performance, suggesting their familial clustering. Finally, cross-trait cross-sibling analyses revealed familial covariation of facial emotion recognition and IQ in siblings discordant for schizophrenia, further indicating their familial etiology. Both traits are important phenotypes for genetic studies and potential early clinical markers of schizophrenia-spectrum disorders. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Implementation of novel statistical procedures and other advanced approaches to improve analysis of CASA data.

    PubMed

    Ramón, M; Martínez-Pastor, F

    2018-04-23

    Computer-aided sperm analysis (CASA) produces a wealth of data that is frequently ignored. The use of multiparametric statistical methods can help explore these datasets, unveiling the subpopulation structure of sperm samples. In this review we analyse the significance of the internal heterogeneity of sperm samples and its relevance. We also provide a brief description of the statistical tools used for extracting sperm subpopulations from the datasets, namely unsupervised clustering (with non-hierarchical, hierarchical and two-step methods) and the most advanced supervised methods, based on machine learning. The former method has allowed exploration of subpopulation patterns in many species, whereas the latter offering further possibilities, especially considering functional studies and the practical use of subpopulation analysis. We also consider novel approaches, such as the use of geometric morphometrics or imaging flow cytometry. Finally, although the data provided by CASA systems provides valuable information on sperm samples by applying clustering analyses, there are several caveats. Protocols for capturing and analysing motility or morphometry should be standardised and adapted to each experiment, and the algorithms should be open in order to allow comparison of results between laboratories. Moreover, we must be aware of new technology that could change the paradigm for studying sperm motility and morphology.

  5. Effect of bending on the room-temperature tensile strengths of structural ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, M.G.

    1992-01-01

    Results for nearly fifty, room-temperature tensile tests conducted on two advanced, monolithic silicon nitride ceramics are evaluated for the effects of bending and application of various Weibull statistical analyses. Two specimen gripping systems (straight collet and tapered collet) were evaluated for both success in producing gage section failures and tendency to minimize bending at failure. Specimen fabrication and grinding technique consderations are briefly reviewed and related to their effects on successful tensile tests. Ultimate tensile strengths are related to the bending measured at specimen failure and the effects of the gripping system on bending are discussed. Finally, comparisons are mademore » between the use of censored and uncensored data sample sets for determining the maximum likelihood estimates of the Weibull parameters from the tensile strength distributions.« less

  6. Effect of bending on the room-temperature tensile strengths of structural ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, M.G.

    1992-07-01

    Results for nearly fifty, room-temperature tensile tests conducted on two advanced, monolithic silicon nitride ceramics are evaluated for the effects of bending and application of various Weibull statistical analyses. Two specimen gripping systems (straight collet and tapered collet) were evaluated for both success in producing gage section failures and tendency to minimize bending at failure. Specimen fabrication and grinding technique consderations are briefly reviewed and related to their effects on successful tensile tests. Ultimate tensile strengths are related to the bending measured at specimen failure and the effects of the gripping system on bending are discussed. Finally, comparisons are mademore » between the use of censored and uncensored data sample sets for determining the maximum likelihood estimates of the Weibull parameters from the tensile strength distributions.« less

  7. Design scenarios for renovation of sports complex: a case study

    NASA Astrophysics Data System (ADS)

    Nižetić, S.

    2018-02-01

    This paper elaborates design scenarios for a sports complex in Croatia from a technical and economic aspect. Different energy options are analysed and two are additionally addressed and discussed as the most viable ones. The possibilities of sports complex renovation are shown by properly choosing the appropriate energy concept and thus reducing the overall cost for produced thermal energy by around 33% and reducing the carbon dioxide emission by a factor of 1.8 in comparison with its present state. Finally, this study presents an example of good practice, where renewable energy solutions can be proposed and where it is possible to cover around 70-80% of overall yearly costs from achieved energy savings for the novel plant that is assumed to be financed through a bank loan.

  8. Dynamic analysis of the American Maglev system. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seda-Sanabria, Y.; Ray, J.C.

    1996-06-01

    Understanding the dynamic interaction between a magnetic levitated (Maglev) vehicle and its supporting guideway is essential in the evaluation of the performance of such a system. This interacting coupling, known as vehicle/guideway interaction (VGI), has a significant effect on system parameters such as the required magnetic suspension forces and gaps, vehicular ride quality, and guideway deflections and stresses. This report presents the VGI analyses conducted on an actual Maglev system concept definition (SCD), the American Maglev SCD, using a linear-elastic finite-element (FE) model. Particular interest was focused on the comparison of the ride quality of the vehicle, using two differentmore » suspension systems, and their effect on the guideway structure. The procedure and necessary assumptions in the modeling are discussed.« less

  9. Final report on COOMET.T-S1. Comparison of type S thermocouples at the freezing points of zinc, aluminium and copper 2014—2015

    NASA Astrophysics Data System (ADS)

    Pokhodun, A. I.; Ivanova, A. G.; Duysebayeva, K. K.; Ivanova, K. P.

    2015-01-01

    Regional comparison of type S thermocouples at the freezing points of zinc, aluminium and copper was initiated by COOMET TC1.1-10 (the technical committee of COOMET `Thermometry and thermal physics'). Three NMI take part in COOMET regional comparison: D I Mendeleev Institute for Metrology (VNIIM) (Russian Federation), National Scientific Centre (Institute of Metrology) (NSC IM, Ukraine), Republic State Enterprise (Kazakhstan Institute of Metrology) (KazInMetr, Republic of Kazakhstan). VNIIM (Russia) was chosen as the coordinator-pilot of the regional comparison. A star type comparison was used. The participants: KazInMetr and NSC IM constructed the type S thermocouples and calibrated them in three fixed points: zinc, aluminum and copper points, using methods of ITS-90 fixed point realizations. The thermocouples have been sent to VNIIM together with the results of the calibration at three fixed points, with the values of the inhomogeneity at temperature 200 °C and the uncertainty evaluations of the results. For calibration of thermocouples the same VNIIM fixed points cells were used. Participating laboratories repeated the calibration of thermocouples after its returning in zinc, aluminum and copper points to determine the stability of its results. In result of the comparison was to evaluate the equivalence of the type S thermocouples calibration in fixed points by NMIs to confirm corresponding lines of international website for NMI's Calibration and Measurement Capabilities (CMC). This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. APMP.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Kang, Namgoo; Bae, Hyun Kil; Woo, Jin Chun; Bi, Zhe; Zhou, Zeyi; Sinweeruthai, Ratirat; Wongjuk, Arnuttachai; Li, Hou; Beng Keat, Teo; Hui, Liu; Wu, Thomas; Hock Ann, Chua; Smeulders, Damian; Briton McCallum, John; Tendai Satumba, Raymond; Shimosaka, Takuya; Matsumoto, Nobuhiro; Kadir, Haslina Abdul; Fauzi Ahmad, Mohamad; Nasir, Noor Hidaya Abdul; Nishino, Tomoe; Akima, Dai; Uehara, Shinji

    2018-01-01

    This document describes the result of a key comparison for propane in nitrogen. The nominal amount-of-substance fraction of propane is 1000 μmol/mol. The comparison aimed to assess the measurement capability of participants in gas analysis. Nine NMIs or DIs participated in the comparison. CERI participated in a key comparison CCQM-K111—propane in nitrogen, and coordinated this key comparison. Therefore, every participants' results of this comparison are linking to the CCQM-K111. Gravimetric values of the samples were used as key comparison reference values (KCRVs). Measured values of eight participants were within +/- 0.25 % of the KCRVs. Many participants reported purity or impurity analysis of materials. These results are also able to assess the participants' capability of the analysis. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Comparison on the calibrations of hydrometers for liquids density determination between SIM laboratories

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Quiroga, Aldo; Daued, Arturo; Cantero, Diana; Sequeira, Francisco; Castro, Luis Carlos; Becerra, Luis Omar; Salazar, Manuel; Vega, Maria

    2017-01-01

    A supplementary comparison was made between SIM laboratories concerning the calibration of four hydrometers within the range of 600 kg/m3 to 2000 kg/m3. The main objectives of the comparison were to evaluate the degree of equivalences SIM NMIs in the calibration of hydrometers of high accuracy. The participant NMIs were: CENAM, IBMETRO, INEN, INDECOPI, INM, INTN and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. A comparison of rural high school students in Germany with rural Tennessee high school students' mathematics and science achievement

    NASA Astrophysics Data System (ADS)

    Harding, R. Fredrick

    This descriptive study compared the science and mathematics aptitudes and achievement test scores for the final school year students in rural White County and Van Buren County, Tennessee with rural county students in Germany. In accordance with the previous research literature (Stevenson, 2002), German students outperformed U.S. students on The International Trends in Math and Science test (TIMSS). As reform in the U.S. education system has been underway, this study intended to compare German county student final school year performance with White County and Van Buren County (Grade 12) performance in science and mathematics. The entire populations of 176 White and Van Buren Counties senior high final school year students were compared with 120 school final year students from two rural German county high schools. The student responses to identical test and questionnaire items were compared using the t-test statistical analysis. In conclusion after t-test analyses, there was no significant difference (p>.05 level) in student attitudes on the 27 problem achievement and the 35 TIMSS questionnaire items between the sampled population of 120 German students compared with the population of 176 White and Van Buren students. Also, there was no statistically significant difference (p>.05 level) between the German, White, and Van Buren County rural science and math achievement in the TIMSS problem section of the final year test. Based on the research, recommendations to improve U.S. student scores to number one in the world include making changes in teaching methodology in mathematics and science; incorporating pamphlet lessons rather than heavily reliance on textbooks; focusing on problem solving; establishing an online clearinghouse for effective lessons; creating national standards in mathematics and science; matching students' course choices to job aspirations; tracking misbehaving students rather than mainstreaming them into the regular classroom; and designing individual educational plans for every student. Further study and future investigations are recommended from this study to compare White County and Van Buren County Students with other rural county schools in Tennessee, as well as other states. In addition, the Tennessee students' state mandated science and mathematics could be correlated to the TIMMS to identify trends and relationships. Future comparisons of White County and Van Buren County with higher scoring rural Asian students could be done in search of more effective methods of teaching science and mathematics.

  13. The fingerprint nature of PCDD in iron ore sinter strand emissions, the effect of suppressants and alternative fuels, and the potential for comparison with the isomer profile of PCDF.

    PubMed

    Ooi, Tze C; Thompson, Dennis; Anderson, David R; Fisher, Ray

    2018-01-01

    It has been previously shown that the isomer profile of PCDF emissions from iron ore sinter plant only varies within limits even when suppressants or alternative fuels are added, to the extent that it can be said to have a 'fingerprint'. The isomer profiles of PCDD from tetra- to hexacholrodibenzo-p-dioxin from the same samples examined for PCDF emissions have been obtained, and show the same tendency for a 'fingerprint ' isomer distribution to occur. Occasional exceptionally high isomer abundances are observed, but these are uncommon. The potential for comparison of the abundances of PCDF and PCDD isomers with similar chlorination patterns to determine whether the same formation process is involved has been examined. It is found that co-elutions prevent extensive comparisons irrespective of whether the SP2331 or DB5ms column is used in the analyses for separation of isomers to provide the results used for comparisons, although they allow limited results to be obtained. It is suggested that analyses using the two chromatography columns to analyse the same sample in parallel could provide more resolution of the isomer profiles for use in comparisons. A pilot study using samples analysed using each column is limited because of detailed differences in the emissions profiles, but demonstrates that greater resolution is possible if the two columns are used to analyse one sample. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Comparison of Estimates between Cohort and Case-Control Studies in Meta-Analyses of Therapeutic Interventions: A Meta-Epidemiological Study.

    PubMed

    Lanza, Amy; Ravaud, Philippe; Riveros, Carolina; Dechartres, Agnes

    2016-01-01

    Observational studies are increasingly being used for assessing therapeutic interventions. Case-control studies are generally considered to have greater risk of bias than cohort studies, but we lack evidence of differences in effect estimates between the 2 study types. We aimed to compare estimates between cohort and case-control studies in meta-analyses of observational studies of therapeutic interventions by using a meta-epidemiological study. We used a random sample of meta-analyses of therapeutic interventions published in 2013 that included both cohort and case-control studies assessing a binary outcome. For each meta-analysis, the ratio of estimates (RE) was calculated by comparing the estimate in case-control studies to that in cohort studies. Then, we used random-effects meta-analysis to estimate a combined RE across meta-analyses. An RE < 1 indicated that case-control studies yielded larger estimates than cohort studies. The final analysis included 23 meta-analyses: 138 cohort and 133 case-control studies. Treatment effect estimates did not significantly differ between case-control and cohort studies (combined RE 0.97 [95% CI 0.86-1.09]). Heterogeneity was low, with between-meta-analysis variance τ2 = 0.0049. Estimates did not differ between case-control and prospective or retrospective cohort studies (RE = 1.05 [95% CI 0.96-1.15] and RE = 0.99 [95% CI, 0.83-1.19], respectively). Sensitivity analysis of studies reporting adjusted estimates also revealed no significant difference (RE = 1.03 [95% CI 0.91-1.16]). Heterogeneity was also low for these analyses. We found no significant difference in treatment effect estimates between case-control and cohort studies assessing therapeutic interventions.

  15. Final report of the supplementary comparison EURAMET.EM-S31 comparison of capacitance and capacitance ratio

    NASA Astrophysics Data System (ADS)

    Schurr, J.; Fletcher, N.; Gournay, P.; Thévenot, O.; Overney, F.; Johnson, L.; Xie, R.; Dierikx, E.

    2017-01-01

    Within the framework of the supplementary comparison EURAMET.EM-S31, 'Comparison of capacitance and capacitance ratio', five participants (the BIPM, METAS, LNE, PTB, and VSL) inter-compared their capacitance realisations traced to the quantum Hall resistance measured at either ac or dc. The measurands were the capacitance values of three 10 pF standards and one 100 pF standard, and optionally their voltage and frequency dependences. Because the results were not fully satisfying, the circulation was repeated, augmented by a link to the NMIA calculable capacitor. Also two ac-dc resistors were circulated and their frequency dependences were measured in terms of the ac-dc resistance standards involved in the particular capacitance realisations, to allow inter-comparison of these resistance standards. At the end and in any case, a good agreement is achieved within the expanded uncertainties at coverage factor k = 2. Furthermore, the comparison led to new insight regarding the stability and travelling behaviour of the capacitance standards and, by virtue of the link to the NMIA calculable capacitor, to a determination of the von Klitzing constant in agreement with the 2014 CODATA value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. KEY COMPARISON Final report on APMP.EM-K6.a: APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty

    NASA Astrophysics Data System (ADS)

    Budovsky, Ilya

    2010-01-01

    The APMP international comparison of ac-dc transfer standards at the lowest attainable level of uncertainty, APMP.EM-K6a, started in 2000 and concluded in 2003. This comparison has offered the same range and frequencies as the key comparison CCEM-K6a with the view of providing the National Metrology Institutes (NMIs) of the APMP member economies with an opportunity to link the values of their standards for ac-dc transfer difference to the international reference values. The ac-dc difference of the travelling standard was measured with 3 V applied at standard frequencies of 1 kHz, 20 kHz, 100 kHz and 1 MHz, and optional frequencies of 50 kHz and 500 kHz. The travelling standard has not been damaged and has shown excellent stability. The results submitted by the overwhelming majority of the participants lie well within the reported uncertainty. At the standard frequencies the results have been linked to those of the CCEM-K6a key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIMT (Thailand) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Khumthukthit, N.; Jassadajin, C.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NIMT (Thailand) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NIMT and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.20 × 10-6 for 1 Ω and 0.74 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the SMD (Belgium) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, Benjamin; Fletcher, Nick; Vlad, Dana

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the SMD (Belgium) and the BIPM carried out in 2017. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the SMD, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13.b (for 10 kΩ). The results from the SMD and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.080 × 10-6 for 1 Ω and 0.068 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Final report on RMO Vickers key comparison COOMET M.H-K1

    NASA Astrophysics Data System (ADS)

    Aslanyan, E.; Menelao, F.; Herrmann, K.; Aslanyan, A.; Pivovarov, V.; Galat, E.; Dovzhenko, Y.; Zhamanbalin, M.

    2013-01-01

    This report describes a COOMET key comparison on Vickers hardness scales involving five National Metrology Institutes: PTB (Germany), BelGIM (Belarus), NSC IM (Ukraine), KazInMetr (Kazakhstan) and VNIIFTRI (Russia). The pilot laboratory was VNIIFTRI, and PTB acted as the linking institute to key comparisons CCM.H-K1.b and CCM.H-K1.c conducted for the Vickers hardness scales HV1 and HV30, respectively. The comparison was also conducted for the HV5 Vickers hardness scale, since this scale is most frequently used in practice in Russia and CIS countries that work according to GOST standards. In the key comparison, two sets of hardness reference blocks for the Vickers hardness scales HV1, HV5 and HV30 consisting each of three hardness reference blocks with hardness levels of 450 HV and 750 HV were used. The measurement results and uncertainty assessments for HV1 and HV30 hardness scales, as announced by BelGIM, NSC IM, KazInMetr and VNIIFTRI, are in good agreement with the key comparison reference values of CCM.H-K1.b and CCM.H-K1.c. The comparison results for the HV5 hardness scale are viewed as additional information, since up to today no CCM key comparisons on this scale have yet been carried out. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Comparison of gaseous exhaust indices of the F109 turbofan using three different blends of petroleum-based Jet-A and camelina-based Jet-A

    NASA Astrophysics Data System (ADS)

    Kozak, Brian John

    This research project focused on the collection and comparison of gaseous exhaust emissions of the F109 turbofan engine using petroleum-based Jet-A and two different blends of camelina-based Jet-A. Simulated landing and takeoff cycles were used to collect gaseous exhaust emissions. Unburned hydrocarbon (HC), nitrogen oxide (NOx), and carbon moNOxide (CO) exhaust indices (EIm) were calculated using ICAO Annex 16 Volume II formulae. Statistical analyses were performed on the Elm data. There was no significant difference in HC EIm and CO EI m among the three fuels at takeoff thrust. There were significant differences among the fuels for NOx EIm. 50% Jet-A 50% camelina produced the highest NOx EIm, then 75% Jet-A 25% camelina and finally Jet-A. At climb thrust, both blends of camelina fuel produced higher NOx EIm but no difference in CO EIm and HC EIm as Jet-A. At approach thrust, both blends of camelina fuel produced higher NOx EIm, lower CO EIm, and no difference in HC EIm as Jet-A. At idle thrust, there was no significant difference among the fuels for NOx EIm. There were significant differences among the fuels for HC EIm. Jet-A and 50% Jet-A 50% both produced higher HC EIm as 75% Jet-A 25% camelina. There were significant differences among the fuels for CO EI m. Jet-A produced the highest CO EIm, then 75% Jet-A 25% camelina and finally 50% Jet-A 50% camelina.

  2. A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement

    PubMed Central

    Young, Tony; Dowsey, Michelle M.; Pandy, Marcus; Choong, Peter F.

    2018-01-01

    Background Medial stabilized total knee joint replacement (TKJR) construct is designed to closely replicate the kinematics of the knee. Little is known regarding comparison of clinical functional outcomes of patients utilising validated patient reported outcome measures (PROM) after medial stabilized TKJR and other construct designs. Purpose To perform a systematic review of the available literature related to the assessment of clinical functional outcomes following a TKJR employing a medial stabilized construct design. Methods The review was performed with a Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) algorithm. The literature search was performed using variouscombinations of keywords. The statistical analysis was completed using Review Manager (RevMan), Version 5.3. Results In the nineteen unique studies identified, there were 2,448 medial stabilized TKJRs implanted in 2,195 participants, there were 1,777 TKJRs with non-medial stabilized design constructs implanted in 1,734 subjects. The final mean Knee Society Score (KSS) value in the medial stabilized group was 89.92 compared to 90.76 in the non-medial stabilized group, with the final KSS mean value difference between the two groups was statistically significant and favored the non-medial stabilized group (SMD 0.21; 95% CI: 0.01 to 0.41; p = 004). The mean difference in the final WOMAC values between the two groups was also statistically significant and favored the medial stabilized group (SMD: −0.27; 95% CI: −0.47 to −0.07; p = 0.009). Moderate to high values (I2) of heterogeneity were observed during the statistical comparison of these functional outcomes. Conclusion Based on the small number of studies with appropriate statistical analysis, we are unable to reach a clear conclusion in the clinical performance of medial stabilized knee replacement construct. Level of Evidence Level II PMID:29696144

  3. Structures in solutions from joint experimental-computational analysis: applications to cyclic molecules and studies of noncovalent interactions.

    PubMed

    Aliev, Abil E; Mia, Zakirin A; Khaneja, Harmeet S; King, Frank D

    2012-01-26

    The potential of an approach combining nuclear magnetic resonance (NMR) spectroscopy, molecular dynamics (MD) simulations, and quantum mechanical (QM) calculations for full structural characterizations in solution is assessed using cyclic organic compounds, namely, benzazocinone derivatives 1-3 with fused five- and eight-membered aliphatic rings, camphoric anhydride 4, and bullvalene 5. Various MD simulations were considered, using force field and semiempirical QM treatments, implicit and explicit solvation, and high-temperature MD calculations for selecting plausible molecular geometries for subsequent QM geometry optimizations using mainly B3LYP, M062X, and MP2 methods. The QM-predicted values of NMR parameters were compared to their experimental values for verification of the final structures derived from the MD/QM analysis. From these comparisons, initial estimates of quality thresholds (calculated as rms deviations) were 0.7-0.9 Hz for (3)J(HH) couplings, 0.07-0.11 Å for interproton distances, 0.05-0.08 ppm for (1)H chemical shifts, and 1.0-2.1 ppm for (13)C chemical shifts. The obtained results suggest that the accuracy of the MD analysis in predicting geometries and relative conformational energies is not critical and that the final geometry refinements of the structures selected from the MD simulations using QM methods are sufficient for correcting for the expected inaccuracy of the MD analysis. A unique example of C(sp(3))-H···N(sp(3)) intramolecular noncovalent interaction is also identified using the NMR/MD/QM and the natural bond orbital analyses. As the NMR/MD/QM approach relies on the final QM geometry optimization, comparisons of geometric characteristics predicted by different QM methods and those from X-ray and neutron diffraction measurements were undertaken using rigid and flexible cyclic systems. The joint analysis shows that intermolecular noncovalent interactions present in the solid state alter molecular geometries significantly compared to the geometries of isolated molecules from QM calculations.

  4. A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement.

    PubMed

    Young, Tony; Dowsey, Michelle M; Pandy, Marcus; Choong, Peter F

    2018-01-01

    Medial stabilized total knee joint replacement (TKJR) construct is designed to closely replicate the kinematics of the knee. Little is known regarding comparison of clinical functional outcomes of patients utilising validated patient reported outcome measures (PROM) after medial stabilized TKJR and other construct designs. To perform a systematic review of the available literature related to the assessment of clinical functional outcomes following a TKJR employing a medial stabilized construct design. The review was performed with a Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) algorithm. The literature search was performed using variouscombinations of keywords. The statistical analysis was completed using Review Manager (RevMan), Version 5.3. In the nineteen unique studies identified, there were 2,448 medial stabilized TKJRs implanted in 2,195 participants, there were 1,777 TKJRs with non-medial stabilized design constructs implanted in 1,734 subjects. The final mean Knee Society Score (KSS) value in the medial stabilized group was 89.92 compared to 90.76 in the non-medial stabilized group, with the final KSS mean value difference between the two groups was statistically significant and favored the non-medial stabilized group (SMD 0.21; 95% CI: 0.01 to 0.41; p = 004). The mean difference in the final WOMAC values between the two groups was also statistically significant and favored the medial stabilized group (SMD: -0.27; 95% CI: -0.47 to -0.07; p = 0.009). Moderate to high values ( I 2 ) of heterogeneity were observed during the statistical comparison of these functional outcomes. Based on the small number of studies with appropriate statistical analysis, we are unable to reach a clear conclusion in the clinical performance of medial stabilized knee replacement construct. Level II.

  5. CCQM key comparison CCQM-K75: Determination of toxic metals in algae

    NASA Astrophysics Data System (ADS)

    Shakhashiro, A.; Toervenyi, A.; Gaudino, S.; Rosamilia, S.; Belli, M.; Turk, G. C.

    2011-01-01

    The determination of mass fraction of toxic elements and especially platinum emitted from automobile catalytic converters in the air is a critical factor in assessing air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to toxic elements. Biomonitors, such as lichen and algae, are examples of environmental samples that have been widely used by the scientific community to assess and monitor the level of environmental pollution. For this purpose, the IAEA-450 algae material containing heavy metals and platinum at low level was prepared by IAEA Seibersdorf Laboratories in collaboration with the Italian National Institute for Environmental Protection—ISPRA (former APAT). During the April meeting in 2009 of the Inorganic Analysis Working Group (IAWG) of the CCQM it was agreed to organize a key comparison K75 for Pt and Ni and a parallel pilot study P118 for As, Cd, Cr, Hg, Ni, Pb and Pt using this algae material. The key comparison CCQM-K75 was successfully organized. The participating NMIs demonstrated a high level of measurement capabilities and technical competence in analysing nickel and platinum at a low level of concentration in environmental samples such as algae. The between-laboratories reproducibility standard deviation for nickel and platinum was 1.9% and 3.6% respectively, which reflects an excellent agreement of between-laboratories measurement results. The ratio between the bias and its expanded uncertainty for nickel and platinum was below 2.0 for all reported results except in one case. This study was a practical demonstration of a CCQM comparison to use the 'core-capabilities' utilized by participants as a mean of providing evidence for Calibration and Measurement Capabilities (CMC) claims for Ni and Pt. Based on this CCQM international key comparison, the measurement capability of the NMIs which participated in the CCQM-K75 has been demonstrated directly for determination of Pt and Ni in algae matrix. In addition, the NMIs demonstrated a wide range of 'core-capabilities' applicable to other measurement applications. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  6. Final report on bilateral supplementary comparison APMP.M.P-S5 in hydraulic gauge pressure from 1 MPa to 10 MPa

    NASA Astrophysics Data System (ADS)

    Yue, J.; Yang, Y.; Sabuga, W.

    2016-01-01

    This report summarizes the results of the Asia-Pacific Metrology Programme (APMP) supplementary comparison APMP.M.P-S5 for hydraulic gauge pressure in the range of 1 MPa to 10 MPa, which is a bilateral comparison carried out at the National Institute of Metrology, China (NIM) and the Physikalisch-Technische Bundesanstalt, Germany (PTB) during the period June 2014 to June 2015. NIM piloted the comparison and provided the transfer standard, which was a piston-cylinder assembly (PCA) of 1 cm2 nominal effective area built in a hydraulic pressure balance manufactured by Fluke Corporation. The laboratory standards of NIM and PTB are both hydraulic pressure balances equipped with PCAs, of which the nominal effective area is 1 cm2 for NIM and 5 cm2 for PTB. The results of the comparison successfully demonstrated that the hydraulic gauge pressure standards of NIM and PTB in the range of 1 MPa to 10 MPa are equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. The quiet revolution: reporting of health outcomes in general medical journals.

    PubMed

    Seymour, J; Newell, D; Shiell, A

    1997-01-01

    This study reviews the extent of evaluation of health outcomes in three general medical journals over the past decade by examining papers published in the original research section of the New England Journal of Medicine (NEJM), The Lancet, and the Medical Journal of Australia (MJA) in 1982 and 1992. Evaluations were identified and classified according to the type of comparison group and the type of outcome measures employed. They were divided into three categories: those employing a comparison group; those employing a before-and-after study design (or own comparison group); and those with no comparison group. The categories of outcome measures were mortality, clinical or intermediate measures of health state, and final outcome measures (quality of life). Results show that the proportion of papers evaluating a health services intervention remained stable over the period. However, the MJA published considerably fewer evaluations than the other journals. In the NEJM and The Lancet, 75 per cent of evaluations incorporated comparison groups, in the MJA, less than 40 per cent. Overall, the proportion of papers reporting final outcome measures increased significantly between 1982 and 1992 (p = 0.04) but the change in each journal individually did not reach statistical significance. This study indicates that the reporting of health outcomes evaluations has remained constant but there has been some change in the use of comparison groups and final outcome measures over time.

  8. SUPPLEMENTARY COMPARISON COOMET. M.P-S5 of hydraulic gauge pressure standards from 5 MPa to 34 MPa

    NASA Astrophysics Data System (ADS)

    Babayev, E. A.; Klenovská, Simona; Páviš, Richard; Pražák, Dominik

    2018-01-01

    This report describes the results of bilateral inter laboratory comparison (BILC) denoted as COOMET.M.P-S5 (also known as supplementary comparison COOMET 723/AZ/17). The comparison measurements between the two participants, Czech Metrology Institute (CMI) (pilot laboratory) and Azerbaijan İnstitute of Metrology (AzMI), started in April 2017 and finished in June 2017. The transfer standards was a digital manometer, Crystal XP 2i with the gauge pressure range (0–34000) kPa. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. KEY COMPARISON: CCEM.RF-K9: International comparison of thermal noise standards between 12.4 GHz and 18 GHz (GT-RF/99-1)

    NASA Astrophysics Data System (ADS)

    Allal, Djamel; Achkar, Joseph

    2006-01-01

    An international comparison of thermal noise-power measurements has been carried out among five national metrology institutes between 12.4 GHz and 18 GHz. Four transfer standards were measured. The following national institutes participated: BNM-LCIE (France), NPL (United Kingdom), PTB (Germany), NIST (United States of America) and VNIIFTRI (Russia). The Bureau National de Métrologie-Laboratoire Central des Industries Electriques (France) acted as the pilot laboratory for the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. SUPPLEMENTARY COMPARISON Bilateral comparison on the calibrations of hydrometers for liquid density between INRIM-Italy and INMETRO-Brazil: SIM.M.D-S2

    NASA Astrophysics Data System (ADS)

    Lorefice, Salvatore; Malta, Dalni; Julio Pinheiro, José; Marteleto, Paulo Roberto

    2010-01-01

    The results of the SIM.M.D-S2 bilateral comparison between INRIM-Italy and INMETRO-Brazil are summarized in this report. The aims of this comparison were to check the stated uncertainty levels and the degrees of equivalence between the two institutes on the calibration of hydrometers for liquid density in the range of 800 kg m-3 to 1000 kg m-3 at 20 ºC, by means of two transfer standards of excellent metrological characteristics. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  11. KEY COMPARISON Comparison of the standards of air kerma of the ENEA-INMRI and the BIPM for 137Cs gamma rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Toni, M.; Bovi, M.

    2010-01-01

    A comparison of the standards of air kerma of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI) and of the Bureau International des Poids et Mesures (BIPM) was carried out in 137Cs radiation in 1998. The comparison result, updated for changes in the standards in 2003 and 2009, is 0.9927 (0.0067) and demonstrates that the ENEA-INMRI and BIPM standards are in agreement within the uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. KEY COMPARISON: Final report on CCEM key comparison CCEM.RF-K10.CL (GT-RF/99-2) 'Power in 50 Ω coaxial lines, frequency: 50 MHz to 26 GHz' measurement techniques and results

    NASA Astrophysics Data System (ADS)

    Janik, Dieter; Inoue, T.; Michaud, A.

    2006-01-01

    This report summarizes the results and the measuring methods of an international key comparison between twelve national metrology institutes (NMIs) and is concerning the calibration factor of RF power sensors in the coaxial 3.5 mm line for frequencies up to 26 GHz. Two RF power travelling standards fitted with male PC 3.5 mm connectors were measured at seven frequencies. The following NMIs participated: NMIJ (Japan), NRC (Canada), NIST (USA), METAS (Switzerland), CSIR-NML (South Africa), NMIA (Australia), NPL (UK), SiQ (Slovenia), IEN (Italy), VNIIFTRI (Russian Federation), SPRING (Singapore) and PTB (Germany), as the pilot laboratory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. SUPPLEMENTARY COMPARISON: Report of the bilateral comparison of the calibrations of hydrometers for liquid density determination between CENAM-Mexico and INRIM-Italy: SIM.M.D-S1

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Lorefice, Salvatore

    2009-01-01

    Hydrometers are instruments usually made of glass which are widely used for different levels of precision to measure liquid density and related quantities to control different products and processes. This bilateral comparison on the calibration of hydrometers shows that results reported by CENAM-Mexico and INRIM-Italy are consistent within the claimed uncertainty in the range of 800 kg/m3 to 1200 kg/m3. This bilateral comparison is intended to link the two regional comparisons SIM.M.D-K4 and EURAMET.D-K4. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Supplementary comparison EURAMET.L-S24 on involute gear standards

    NASA Astrophysics Data System (ADS)

    Kniel, K.; Chanthawong, N.; Eastman, N.; Frazer, R.; Kupko, V.; Osawa, S.; Xue, Z.

    2014-01-01

    At its meeting in 2007, the EURAMET TC-Length decided to run an intercomparison of involute gear standards as a regional comparison with non-European involvement. The Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany (PTB) was identified as the pilot laboratory, responsible for planning, organizing and analyzing the comparison. In all, seven participants from China, Germany, Japan, Thailand, Ukraine, United Kingdom and USA were asked to measure three different gear standards specialized for profile, helix and pitch measurements. The measurements started mid 2008 and were finished at the end of 2010. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The comparison was registered as the supplementary comparison EURAMET.L-S24. The final report has been peer-reviewed and approved for publication by the CCL WG-MRA, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report of the key comparison APMP.QM-K91: APMP comparison on pH measurement of phthalate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Ketrin, Rosi; Nuryatini; Thanh, Ngo Huy; Truong Chinh, Nguyen; Vospelova, Alena; Bastkowski, Frank; Sander, Beatrice; Matzke, Jessica; Prokunin, Sergey; Frolov, Dmitry; Aprelev, Alexey; Dobrovolskiy, Vladimir; Uysal, Emrah; Liv, Lokman; Velina Lara-Manzano, Judith; Montero-Ruiz, Jazmin; Ortiz-Aparicio, JosÉ Luis; Ticona Canaza, Galia; Anuar Mohd Amin, Khirul; Abd Kadir, Haslina; Bakovets, Nickolay; Wong, Siu-Kay; Lam, Wai-Hing

    2017-01-01

    The APMP.QM-K91 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phthalate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan at the APMP-TCQM meeting held September 22-23, 2014. After approval by TCQM, the comparison has been conducted by NMIJ. The comparison is a key comparison following CCQM-K91. The comparison material was a phthalate buffer of pH around 4.0 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the third APMP key comparison on pH measurement and the fifth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006, APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011 and APMP.QM-K19/APMP.QM-P25 (a borate buffer) in 2013-2014. The results can be used further by any participant to support its CMC claim at least for a phthalate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. KEY COMPARISON: Final report on APMP.M.P-K6.1 pneumatic key comparison from 20 kPa to 105 kPa in gauge mode

    NASA Astrophysics Data System (ADS)

    Hung, Chen-Chuan; Jian, Wu; Changpan, Tawat

    2009-01-01

    This report describes the key comparison APMP.M.P-K6.1 among the three national metrology institutes, Center for Measurement Standards-ITRI (CMS-ITRI, Taiwan), SPRING Singapore and National Institute of Metrology (NIMT), in the pressure range from 20 kPa to 105 kPa in gas media and gauge mode executed during the period April 2003 to April 2004. This comparison was conducted by CMS-ITRI and was based on the calibration procedure of APMP pneumatic pressure comparison APMP.M.P-K6. We intended to link to the CCM.P-K6 key comparison through the APMP.M.P-K6 key comparison by using the proposed linkage method in the APMP.M.P-K6 key comparison to determine a linking factor that can transform the quantities measured in the APMP.M.P-K6.1 key comparison. All three participating institutes used pneumatic piston gauges as their pressure standards. The Ruska 2465 gas-operated piston-cylinder assembly TL-1409 used as transfer standard offered by CMS-ITRI was calibrated three times by the pilot institute during the comparison period and showed that it was very stable after evaluation. The comparison was conducted on the basis of cross-float experiments to determine the effective area of transfer standards from the national standards of three institutes. The comparison results (as shown in Table 6) were equivalent to the CCM.P-K6 comparison and the relative bilateral degrees of equivalence between two laboratories were smaller than 39.7 × 10-6 from 20 kPa to 105 kPa. These results showed all participating institutes measuring the same quantity in the whole pressure range lay within their expanded uncertainty with confidence level 95%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  17. Measurement of Hadronic Event Shapes and Jet Substructure in Proton-Proton Collisions at 7.0 TeV Center-of-Mass Energy with the ATLAS Detector at the Large Hadron Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David Wilkins

    2012-03-20

    This thesis presents the first measurement of 6 hadronic event shapes in proton-proton collisions at a center-of-mass energy of {radical}s = 7 TeV using the ATLAS detector at the Large Hadron Collider. Results are presented at the particle-level, permitting comparisons to multiple Monte Carlo event generator tools. Numerous tools and techniques that enable detailed analysis of the hadronic final state at high luminosity are described. The approaches presented utilize the dual strengths of the ATLAS calorimeter and tracking systems to provide high resolution and robust measurements of the hadronic jets that constitute both a background and a signal throughout ATLASmore » physics analyses. The study of the hadronic final state is then extended to jet substructure, where the energy flow and topology within individual jets is studied at the detector level and techniques for estimating systematic uncertainties for such measurements are commissioned in the first data. These first substructure measurements in ATLAS include the jet mass and sub-jet multiplicity as well as those concerned with multi-body hadronic decays and color flow within jets. Finally, the first boosted hadronic object observed at the LHC - the decay of the top quark to a single jet - is presented.« less

  18. Comparison of measurement standards of the acoustic pressure in air in the low frequency range: COOMET.AUV.A-K2

    NASA Astrophysics Data System (ADS)

    Chalyy, V.

    2011-01-01

    A bilateral regional comparison of national microphone standards from 2 Hz to 250 Hz was carried out between the DP NDI 'Systema' (Ukraine) and the VNIIFTRI (Russia) from July to September 2009. The comparison, COOMET.AUV.A-K2, was based on the pressure calibration of laboratory standard microphones type LSIP. The comparison results have been linked to the established key comparison reference value (KCRV) of CCAUV.A-K2. The degrees of equivalence, expressed as the deviation from the established KCRV and its expanded uncertainty (k = 2), have been determined, and the comparison result is in agreement with the KCRV within the estimated uncertainties at all employed frequencies. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Bilateral comparison of 1 Ω standards (ongoing BIPM key comparison BIPM.EM-K13.a) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 1 Ω resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The mean difference between the NMLI and the BIPM calibrations was found to be just within the expanded uncertainty (k = 2) of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Creating a literature database of low-calorie sweeteners and health studies: evidence mapping.

    PubMed

    Wang, Ding Ding; Shams-White, Marissa; Bright, Oliver John M; Parrott, J Scott; Chung, Mei

    2016-01-05

    Evidence mapping is an emerging tool used to systematically identify, organize and summarize the quantity and focus of scientific evidence on a broad topic, but there are currently no methodological standards. Using the topic of low-calorie sweeteners (LCS) and selected health outcomes, we describe the process of creating an evidence-map database and demonstrate several example descriptive analyses using this database. The process of creating an evidence-map database is described in detail. The steps include: developing a comprehensive literature search strategy, establishing study eligibility criteria and a systematic study selection process, extracting data, developing outcome groups with input from expert stakeholders and tabulating data using descriptive analyses. The database was uploaded onto SRDR™ (Systematic Review Data Repository), an open public data repository. Our final LCS evidence-map database included 225 studies, of which 208 were interventional studies and 17 were cohort studies. An example bubble plot was produced to display the evidence-map data and visualize research gaps according to four parameters: comparison types, population baseline health status, outcome groups, and study sample size. This plot indicated a lack of studies assessing appetite and dietary intake related outcomes using LCS with a sugar intake comparison in people with diabetes. Evidence mapping is an important tool for the contextualization of in-depth systematic reviews within broader literature and identifies gaps in the evidence base, which can be used to inform future research. An open evidence-map database has the potential to promote knowledge translation from nutrition science to policy.

  1. Meat and milk intakes and toddler growth: a comparison feeding intervention of animal-source foods in rural Kenya.

    PubMed

    Long, Jennifer K; Murphy, Suzanne P; Weiss, Robert E; Nyerere, Susan; Bwibo, Nimrod O; Neumann, Charlotte G

    2012-06-01

    To examine the effects of animal-source foods on toddler growth. A 5-month comparison feeding intervention study with one of three millet-based porridges randomized to eighteen feeding stations serving 303 children aged 11-40 months. Feeding stations served plain millet porridge (Plain group), porridge with milk (Milk group) or porridge with beef (Meat group). Anthropometry, morbidity and food intake were measured at baseline and regular intervals. Longitudinal mixed models were used to analyse growth. Embu, Kenya. Two hundred and seventy-four children were included in final analyses. Linear growth was significantly greater for the Milk group than the Meat group (P = 0·0025). Slope of growth of mid-arm muscle area of the Plain group was significantly greater than in the Meat group (P = 0·0046), while the Milk group's mid-upper arm circumference growth rate was significantly greater than the Meat group's (P = 0·0418). The Milk and Plain groups' measures did not differ. Milk and meat porridges did not have a significantly greater effect on growth than plain porridge in this undernourished population. Linear growth was influenced by more than energy intakes, as the Plain group's total body weight-adjusted energy intakes were significantly greater than the Meat group's, although linear growth did not differ. Energy intakes may be more important for growth in arm muscle. The diverse age distribution in the study makes interpretation difficult. A longer study period, larger sample size and more focused age group would improve clarity of the results.

  2. Numerical Investigations On The Seismic Behaviour Of Confined Masonry Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calderini, Chiara; Cattari, Serena; Lagomarsino, Sergio

    2008-07-08

    In the last century, severe earthquakes highlighted the seismic vulnerability of unreinforced masonry buildings. Many technological innovations have been introduced in time in order to improve resistance, ductility, and dissipation properties of this type of constructions. The most widely diffused are reinforced masonry and confined masonry. Damage observation of recent earthquakes demonstrated the effectiveness of the response of confined masonry structures to seismic actions. In general, in this type of structures, reinforced concrete beams and columns are not main structural elements, however, they have the following functions: to confine masonry in order to increase its ductility; to bear tensile stressesmore » derived from bending; to contrast the out-of-plane overturning of masonry panels. It is well evident that these functions are as much effectively performed as the connection between masonry and reinforced concrete elements is good (for example by mean of local interlocking or reinforcements). Confined masonry structures have been extensively studied in the last decades both from a theoretical point of view and by experimental tests Aims of this paper is to give a contribution to the understanding of the seismic behaviour of confined masonry walls by means of numerical parametrical analyses. There latter are performed by mean of the finite element method; a nonlinear anisotropic constitutive law recently developed for masonry is adopted. Comparison with available experimental results are carried out in order to validate the results. A comparison between the resistance obtained from the numerical analyses and the prevision provided by simplified resistance criteria proposed in literature and in codes is finally provided.« less

  3. Comparison of the Victorian Audit of Surgical Mortality with coronial cause of death.

    PubMed

    Hansen, Dylan; Retegan, Claudia; Woodford, Noel; Vinluan, Jessele; Beiles, Charles B

    2016-06-01

    The Victorian Audit of Surgical Mortality (VASM) is designed to improve the level of patient care by educating surgeons of areas for improvement in patient management during a surgical admission. Coronial data obtained via the National Coronial Information System were used as an independent method to validate the cause of death as determined by the treating surgeon. The audit prospectively collected 4905 cases that underwent peer assessment and 842 (17%) received an in-depth second-line assessment of which 200 (24%) also underwent a coronial review. Using the coronial assessment as the reference standard, retrospective comparison of coronial diagnoses compared with the audit case outcomes was conducted to determine the overall accuracy of the stated cause of death. The degree of agreement was also analysed based on whether the patient received a full autopsy (internal examination) or an external examination only. The time taken to obtain the coronial and audit case closure was also analysed. Overall, 195 of the 200 cases had a cause of death identified by the coroner. In 82%, the cause of death reported to VASM by the treating surgeon matched the cause of death determined by the coroner. Concordance was not affected by the extent of post-mortem performed. Time taken to finalize cases was slightly shorter for the coronial process, but unclosed coronial findings resulted in the exclusion of 103 cases. The causes of death data in VASM are accurate when compared with the coronial data independent of whether the coronial investigation included a complete autopsy. © 2015 Royal Australasian College of Surgeons.

  4. Final report of AFRIMETS.M.M-S6: supplementary comparison of 100 mg, 100 g 500 g, 1 kg and 5 kg stainless steel mass standards

    NASA Astrophysics Data System (ADS)

    Mautjana, R. T.; Molefe, P. T.; Mayindu, N. F.; Armah, M. N.; Ramasawmy, V.; Albasini, G. L.; Matali, S.; Richmond, H.; Rusimbi, V.; Kiwanuka, J.; Mutale, D. M.; Mutsimba, F.

    2018-01-01

    This report summarizes the results of AFRIMETS.M.M-S6 mass standards comparison conducted between eleven participating laboratories/countries. Two sets of five weights with nominal values 100 mg, 100 g, 500 g, 1 kg and 5 kg were used as the traveling standards. These nominal values were decided from the needs of participating laboratories submitted to the pilot laboratory through a questionnaire and agreed upon by all participants. The traveling standards were hand carried between laboratories starting from February 2014 and were received from the last participants in October 2014. The programme was coordinated by National Metrology Institute of South Africa (NMISA), who provided the travelling standards and reference values for the comparison. The corrections to the BIPM as-maintained mass unit [5] have insignificant influence on the results of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Final report of the key comparison of APMP.AUV.V-K2

    NASA Astrophysics Data System (ADS)

    Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui

    2017-01-01

    A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report on APMP.RF-S21.F

    NASA Astrophysics Data System (ADS)

    Ishii, Masanori; Kim, Jeong Hwan; Ji, Yu; Cho, Chi Hyun; Zhang, Tim

    2018-01-01

    The supplementary comparison report APMP.RF-S21.F describes the comparison of loop antennas, which was conducted between April 2013 and January 2014. The two comparison artefacts were well-characterised active loop antennas of diameter 30 cm and 60 cm respectively, which typically operate in a frequency range from 9 kHz to 30 MHz. These antennas represent the main groups of antennas which are used around the world for EMC measurements in the frequency range below 30 MHz. There are several well-known methods for calibrating the antenna factor of these devices. The calibration systems used in this comparison for the loop antennas employed the standard magnetic field method or the three-antenna method. Despite the limitations of the algorithm, which we used to derive the reference value for each case (particularly for small samples), the actual calculated reference values seem to be reasonable. As a result, the agreement between each participant was very good in all cases. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Final report on APMP.T-K7 key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Tsai, S. F.; White, R.; Tamba, J.; Yamazawa, K.; Ho, M. K.; Tsui, C. M.; Zaid, G.; Achmadi, A.; Gam, K. S.; Othman, H.; Ali, N. M.; Yuan, K. H.; Shaochun, Y.; Liedberg, H.; Yaokulbodee, C.

    2016-01-01

    APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final report on the key comparison, CCM.P-K15 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Arai, Kenta; Bergoglio, Mercede; Fedchak, James A.; Jousten, Karl; Hong, Seung Soo; Torres Guzman, Jorge

    2017-01-01

    The comparison CCM.P-K15 is a key comparison in pressure involving six laboratories in three regional metrological organizations (RMO). The measurand of the comparison is the accommodation coefficient of two spinning rotating gauge characterized in nitrogen from 0.1 mPa up to 1.0 Pa. The two transfer standards were circulated from November 2009 until March 2011. The circulation consisted of three loops, one for each RMO, and a new calibration by the pilot be-tween each loop. The stability of one of the transfer standards was poor and was worse than expected based on the previous history of the transfer standard while the other transfer standard demonstrated good stability while circulated in Europe and America and a fair stability while circulated in Asia. All the participants demonstrated equivalence to the definition of pressure in their respective primary standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on regional supplementary comparison SIM.M.FF-S5: Volume of liquids at 50 mL

    NASA Astrophysics Data System (ADS)

    Morales, Abed; Malta, Dalni; Kornblit, Fernando; Ramírez, Ruben R.; Arias, Roberto; Trujillo, Sonia

    2012-01-01

    A regional supplementary comparison for the volume of liquid at 50 mL was conducted during October 2009 to June 2010 between the SIM members CENAM, INTI, INMETRO, INDECOPI and INTN. The transfer standard consisted of two 50 mL glass pycnometers, of the Gay Lussac type. CENAM acted as the pilot, collected the measurement results, analyzed the data and produced the comparison report. The median of all participants' results was used to calculate the regional comparison reference value because the result for one of the two pycnometers in one laboratory failed the chi-squared test at the 0.05 probability level. The measurements reported by the participants show an excellent overlap in four out of the five NMIs (-34×10-6 < Di < 29×10-6). The degree of equivalence obtained herein will be taken into account for the preparation of calibration and measurement capabilities claims from the participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the SIM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.; Rujirat, N.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Fundamental period of Italian reinforced concrete buildings: comparison between numerical, experimental and Italian code simplified values

    NASA Astrophysics Data System (ADS)

    Ditommaso, Rocco; Carlo Ponzo, Felice; Auletta, Gianluca; Iacovino, Chiara; Nigro, Antonella

    2015-04-01

    Aim of this study is a comparison among the fundamental period of reinforced concrete buildings evaluated using the simplified approach proposed by the Italian Seismic code (NTC 2008), numerical models and real values retrieved from an experimental campaign performed on several buildings located in Basilicata region (Italy). With the intention of proposing simplified relationships to evaluate the fundamental period of reinforced concrete buildings, scientists and engineers performed several numerical and experimental campaigns, on different structures all around the world, to calibrate different kind of formulas. Most of formulas retrieved from both numerical and experimental analyses provides vibration periods smaller than those suggested by the Italian seismic code. However, it is well known that the fundamental period of a structure play a key role in the correct evaluation of the spectral acceleration for seismic static analyses. Generally, simplified approaches impose the use of safety factors greater than those related to in depth nonlinear analyses with the aim to cover possible unexpected uncertainties. Using the simplified formula proposed by the Italian seismic code the fundamental period is quite higher than fundamental periods experimentally evaluated on real structures, with the consequence that the spectral acceleration adopted in the seismic static analysis may be significantly different than real spectral acceleration. This approach could produces a decreasing in safety factors obtained using linear and nonlinear seismic static analyses. Finally, the authors suggest a possible update of the Italian seismic code formula for the simplified estimation of the fundamental period of vibration of existing RC buildings, taking into account both elastic and inelastic structural behaviour and the interaction between structural and non-structural elements. Acknowledgements This study was partially funded by the Italian Civil Protection Department within the project DPC-RELUIS 2014 - RS4 ''Seismic observatory of structures and health monitoring''. References R. Ditommaso, M. Vona, M. R. Gallipoli and M. Mucciarelli (2013). Evaluation and considerations about fundamental periods of damaged reinforced concrete buildings. Nat. Hazards Earth Syst. Sci., 13, 1903-1912, 2013. www.nat-hazards-earth-syst-sci.net/13/1903/2013. doi:10.5194/nhess-13-1903-2013

  12. Accurate 3d Scanning of Damaged Ancient Greek Inscriptions for Revealing Weathered Letters

    NASA Astrophysics Data System (ADS)

    Papadaki, A. I.; Agrafiotis, P.; Georgopoulos, A.; Prignitz, S.

    2015-02-01

    In this paper two non-invasive non-destructive alternative techniques to the traditional and invasive technique of squeezes are presented alongside with specialized developed processing methods, aiming to help the epigraphists to reveal and analyse weathered letters in ancient Greek inscriptions carved in masonry or marble. The resulting 3D model would serve as a detailed basis for the epigraphists to try to decipher the inscription. The data were collected by using a Structured Light scanner. The creation of the final accurate three dimensional model is a complicated procedure requiring large computation cost and human effort. It includes the collection of geometric data in limited space and time, the creation of the surface, the noise filtering and the merging of individual surfaces. The use of structured light scanners is time consuming and requires costly hardware and software. Therefore an alternative methodology for collecting 3D data of the inscriptions was also implemented for reasons of comparison. Hence, image sequences from varying distances were collected using a calibrated DSLR camera aiming to reconstruct the 3D scene through SfM techniques in order to evaluate the efficiency and the level of precision and detail of the obtained reconstructed inscriptions. Problems in the acquisition processes as well as difficulties in the alignment step and mesh optimization are also encountered. A meta-processing framework is proposed and analysed. Finally, the results of processing and analysis and the different 3D models are critically inspected and then evaluated by a specialist in terms of accuracy, quality and detail of the model and the capability of revealing damaged and "hidden" letters.

  13. Personal Self and Collective Self: When Academic Choices Depend on the Context of Social Comparison

    ERIC Educational Resources Information Center

    Chazal, Sebastien; Guimond, Serge; Darnon, Celine

    2012-01-01

    This research examines the impact of same-sex versus opposite-sex social comparisons on the perception of one's own abilities at school and subsequent reported marks and academic choices. During their final year, male and female high school students were asked to describe themselves either in comparison with boys in their class, in comparison with…

  14. Solar radiation variability over La Réunion island and associated larger-scale dynamics

    NASA Astrophysics Data System (ADS)

    Mialhe, Pauline; Morel, Béatrice; Pohl, Benjamin; Bessafi, Miloud; Chabriat, Jean-Pierre

    2017-04-01

    This study aims to examine the solar radiation variability over La Réunion island and its relationship with large-scale circulation. The Satellite Application Facility on Climate Monitoring (CM SAF) produces a Shortwave Incoming Solar radiation (SIS) data record called Solar surfAce RAdiation Heliosat - East (SARAH-E). A comparison to in situ observations from Météo-France measurements networks quantifies the skill of SARAH-E grids which we use as dataset. First step of the work, irradiance mean cycles are calculated to describe the diurnal-seasonal SIS behaviour over La Réunion island. By analogy with the climate anomalies, instantaneous deviations are computed after removal of the mean states. Finally, we associate these anomalies with larger-scale atmospheric dynamics into the South West Indian Ocean by applying multivariate clustering analyses (Hierarchical Ascending Classification, k-means).

  15. Cooperation of German Airports in Europe: Comparison of Different Types by Means of an Interdependence-Profile-Model

    NASA Technical Reports Server (NTRS)

    Meincke, Peter A.

    2003-01-01

    The limited growth possibilities in the home markets - not the least of which, based on capacity and expansion problems - force the large airport operators to enter into, via partnerships, cooperations and alliances. The German airports already cooperate among one another in different forms. The purpose of the paper is to examine the structures and possibilities of cooperation among airports in Europe (e.g. Airport Systems, Airport Networks). The experience of German airports with different cooperations and alliances will be also considered. Finally the forms of cooperations among airports are analysed by means of interdependence-profile-models with different features (mutual dependence, coordination volume, complexity, cooperation profit, value, degree of formalization and temporal frame), in order to find out how high the cooperative attachment of cooperation is to be evaluated.

  16. Cell-block procedure in endoscopic ultrasound-guided-fine-needle-aspiration of gastrointestinal solid neoplastic lesions

    PubMed Central

    Ieni, Antonio; Barresi, Valeria; Todaro, Paolo; Caruso, Rosario Alberto; Tuccari, Giovanni

    2015-01-01

    In the present review we have analyzed the clinical applications of endoscopic ultrasound-guided-fine-needle-aspiration (EUS-FNA) and the methodological aspects obtained by cell-block procedure (CBP) in the diagnostic approach to the gastrointestinal neoplastic pathology. CBP showed numerous advantages in comparison to the cytologic routine smears; in particular, better preservation of cell architecture, achievement of routine haematoxylin-eosin staining equivalent to histological slides and possibility to perform immunohistochemistry or molecular analyses represented the most evident reasons to choose this method. Moreover, by this approach, the differential diagnosis of solid gastrointestinal neoplasias may be more easily achieved and the background of contaminant non-neoplastic gastrointestinal avoided. Finally, biological samples collected by EUS-FNA CBP-assisted should be investigated in order to identify and quantify further potential molecular markers. PMID:26322154

  17. Protamines and spermatogenesis in Drosophila and Homo sapiens : A comparative analysis.

    PubMed

    Kanippayoor, Rachelle L; Alpern, Joshua H M; Moehring, Amanda J

    2013-04-01

    The production of mature and motile sperm is a detailed process that utilizes many molecular players to ensure the faithful execution of spermatogenesis. In most species that have been examined, spermatogenesis begins with a single cell that undergoes dramatic transformation, culminating with the hypercompaction of DNA into the sperm head by replacing histones with protamines. Precise execution of the stages of spermatogenesis results in the production of motile sperm. While comparative analyses have been used to identify similarities and differences in spermatogenesis between species, the focus has primarily been on vertebrate spermatogenesis, particularly mammals. To understand the evolutionary basis of spermatogenetic variation, however, a more comprehensive comparison is needed. In this review, we examine spermatogenesis and the final packaging of DNA into the sperm head in the insect Drosophila melanogaster and compare it to spermatogenesis in Homo sapiens.

  18. Report of the key-comparison of spectral diffuse reflectance (EURAMET.PR-K5) (Ref. 619)

    NASA Astrophysics Data System (ADS)

    Andor, György; Gál, Péter

    2018-01-01

    This report details the final results of the EURAMET comparison on regular spectral transmittance carried out between 2006 and 2016. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 780 nm at 20 nm increment. We used a star type comparison: first the participants sent their samples to the pilot, than the pilot measured all the samples of the participants and sent them back. The participants measured the samples and sent them to the pilot for control measurement. Six standards were used as reference standards in order to maintain the scale during the comparison. These were three samples of BCR-406 opal glasses (BCR 30506; BCR 30303; BCR 30704), an MC20 Russian opal glass (MC 4777) and two samples made of pressed halon (polytetrafluoroethylene) powder (halon 2007A; halon 2007C). These six samples were designated as the Comparison reference standards. The diffuse reflectance was initially measured on the OMH (BFKH) absolute reflectometer. The link to the CCPR-K5 results was BFKH, and the check on BFKH was the PTB results who also participated in the CCPR-K5 comparison. The participants were GUM, INM, LNE, METAS, BFKH, PTB, SP. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Analyses of Eighth Grade Math Texts and Achievement (Evaluation Report). What Works Clearinghouse Brief Study Report

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2005

    2005-01-01

    This report reviews a study of the effects of "Saxon Algebra 1/2" on the mathematics achievement of 8th-grade students and a comparison of textbook content between the intervention and comparison curricula (Crawford & Raia, 1986). Crawford and Raia conducted three analyses with different subsets of the overall sample, but only one analysis is…

  20. Evaluation of the Air Quality Monitor's Performance on the International Space Station

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Reese, Eric; Ballard, Ken; Durham, Tamara

    2010-01-01

    The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.

  1. Rotorcraft Conceptual Design Environment

    DTIC Science & Technology

    2009-10-01

    systems engineering design tool sets. The DaVinci Project vision is to develop software architecture and tools specifically for acquisition system...enable movement of that information to and from analyses. Finally, a recently developed rotorcraft system analysis tool is described. Introduction...information to and from analyses. Finally, a recently developed rotorcraft system analysis tool is described. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION

  2. Exercise self-identity: interactions with social comparison and exercise behaviour.

    PubMed

    Verkooijen, Kirsten T; de Bruijn, Gert-Jan

    2013-01-01

    Possible interactions among exercise self-identity, social comparison and exercise behaviour were explored in a sample of 417 undergraduate students (mean age = 21.5, SD = 3.0; 73% female). Two models were examined using self-report data; (1) a mediation model which proposed an association between social comparison and exercise behaviour mediated by exercise self-identity and (2) a moderation model proposing an association between exercise behaviour and self-identity moderated by social comparison. Results of the mediation analyses revealed partial mediation of the social comparison--exercise behaviour relationship by self-identity in females. Results of the moderation analyses revealed in males a significant interaction of social comparison with exercise behaviour in the prediction of self-identity - the positive association between exercise behaviour and exercise self-identity showed only significant among male students who believed to exercise equally much or less than peers. Possible explanations and implications for exercise promotion are discussed.

  3. Final report on key comparison EURAMET.M.P-K13 in the range 50 MPa to 500 MPa of hydraulic gauge pressure

    NASA Astrophysics Data System (ADS)

    Kocas, I.; Sabuga, W.; Bergoglio, M.; Eltaweel, A.; Korasie, C.; Farar, P.; Setina, J.; Waller, B.; Durgut, Y.

    2015-01-01

    The regional key comparison EURAMET.M.P-K13 for pressure measurements in liquid media from 50 MPa to 500 MPa was piloted by the TÜBİTAK UME Pressure Group Laboratories, Turkey. The transfer standard was a DH-Budenberg pressure balance with a free deformation piston-cylinder unit of 2 mm2 nominal effective area. Six laboratories from the EURAMET region, namely PTB, INRIM, SMU, IMT, NPL and UME, and two laboratories from the AFRIMETS region, NIS and NMISA participated in this comparison. Participant laboratories and countries are given in the bottom of the page. PTB participated in this comparison to provide a link to corresponding 500 MPa CCM key comparison CCM.P-K13. The results of all participants excepting NMISA and NPL were found to be consistent with the reference value of the actual comparison and of CCM.P-K13 within their claimed uncertainties (k = 2), at all pressures. Compared in pairs all laboratories with exception of NPL and NMISA demonstrate their agreement with each other within the expanded uncertainties (k = 2) at all pressures. The results are therefore considered to be satisfactory. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the CMI (Czech Republic) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Kučera, J.; Chrobok, P.; Vo&jacute; čko&vacute; , L.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the CMI (Czech Republic) and the BIPM carried out in 2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the CMI and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.046 × 10-6 for 1 Ω and 0.034 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Power, O.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Approaches to self-assembly of colloidal monolayers: A guide for nanotechnologists.

    PubMed

    Lotito, Valeria; Zambelli, Tomaso

    2017-08-01

    Self-assembly of quasi-spherical colloidal particles in two-dimensional (2D) arrangements is essential for a wide range of applications from optoelectronics to surface engineering, from chemical and biological sensing to light harvesting and environmental remediation. Several self-assembly approaches have flourished throughout the years, with specific features in terms of complexity of the implementation, sensitivity to process parameters, characteristics of the final colloidal assembly. Selecting the proper method for a given application amidst the vast literature in this field can be a challenging task. In this review, we present an extensive classification and comparison of the different techniques adopted for 2D self-assembly in order to provide useful guidelines for scientists approaching this field. After an overview of the main applications of 2D colloidal assemblies, we describe the main mechanisms underlying their formation and introduce the mathematical tools commonly used to analyse their final morphology. Subsequently, we examine in detail each class of self-assembly techniques, with an explanation of the physical processes intervening in crystallization and a thorough investigation of the technical peculiarities of the different practical implementations. We point out the specific characteristics of the set-ups and apparatuses developed for self-assembly in terms of complexity, requirements, reproducibility, robustness, sensitivity to process parameters and morphology of the final colloidal pattern. Such an analysis will help the reader to individuate more easily the approach more suitable for a given application and will draw the attention towards the importance of the details of each implementation for the final results. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIS (Egypt) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Helmy, M.; Raouf, A.; Hamed, Heba A. M.; Eliwa Gad, A.

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NIS (Egypt) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NIS, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NIS and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of about 0.72 × 10-6 at 10 pF and about 0.65 × 10-6 at 100 pF. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. The development of phonological skills in late and early talkers

    PubMed Central

    KEHOE, Margaret; CHAPLIN, Elisa; MUDRY, Pauline; FRIEND, Margaret

    2016-01-01

    This study examined the relationship between phonological and lexical development in a group of French-speaking children (n=30), aged 29 months. The participants were divided into three sub-groups based on the number of words in their expressive vocabulary : low vocabulary (below the 15th percentile) (<< late-talkers >>) ; average-sized vocabulary (40-60th percentile) (<< middle group >>) and advanced vocabulary (above the 90th percentile) (<< precocious >> or “early talkers”). The phonological abilities (e.g., phonemic inventory, percentage of correct consonants, and phonological processes) of the three groups were compared. The comparison was based on analyses of spontaneous language samples. Most findings were consistent with previous results found in English-speaking children, indicating that the phonological abilities of late talkers are less well developed than those of children with average-sized vocabularies which in turn are less well-developed than those of children with advanced vocabularies. Nevertheless, several phonological measures were not related to vocabulary size, in particular those concerning syllable-final position. These findings differ from those obtained in English. The article finally discusses the clinical implications of the findings for children with delayed language development. PMID:26924855

  9. Engine System Loads Analysis Compared to Hot-Fire Data

    NASA Technical Reports Server (NTRS)

    Frady, Gregory P.; Jennings, John M.; Mims, Katherine; Brunty, Joseph; Christensen, Eric R.; McConnaughey, Paul R. (Technical Monitor)

    2002-01-01

    Early implementation of structural dynamics finite element analyses for calculation of design loads is considered common design practice for high volume manufacturing industries such as automotive and aeronautical industries. However with the rarity of rocket engine development programs starts, these tools are relatively new to the design of rocket engines. In the NASA MC-1 engine program, the focus was to reduce the cost-to-weight ratio. The techniques for structural dynamics analysis practices, were tailored in this program to meet both production and structural design goals. Perturbation of rocket engine design parameters resulted in a number of MC-1 load cycles necessary to characterize the impact due to mass and stiffness changes. Evolution of loads and load extraction methodologies, parametric considerations and a discussion of load path sensitivities are important during the design and integration of a new engine system. During the final stages of development, it is important to verify the results of an engine system model to determine the validity of the results. During the final stages of the MC-1 program, hot-fire test results were obtained and compared to the structural design loads calculated by the engine system model. These comparisons are presented in this paper.

  10. Clinical reasoning skills in final-year dental students: A qualitative cross-curricula comparison.

    PubMed

    Nafea, E T; Dennick, R

    2018-05-01

    The aim of this research was to explore the perceptions of undergraduate dental students regarding clinical reasoning skills and also discover the influences of different curriculum designs on the acquisition of these skills by students. Eighteen final-year students from three different dental schools with varied curricula and cultures participated in the current research. The research used qualitative methodology. The study took place in 2013-2014. Interviews captured the participants' own understanding of clinical reasoning and its acquisition plus they "talked through" a clinical problem using a "think-aloud" technique. Thematic analysis was used to analyse the transcripts of the recorded interviews. Results obtained were related to curriculum structure. Unfamiliarity with the term clinical reasoning was common in students. Students from different schools used different strategies to reason when discussing clinical vignettes. Clinical reasoning process was dominated by pattern recognition. Students' behaviours seemed to be influenced by cultural factors. This research contributes to a greater understanding of how students learn, understand and apply dental clinical reasoning which will improve educational practices in the future. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Results of the EURAMET.RI(II)-S6.I-129 supplementary comparison

    NASA Astrophysics Data System (ADS)

    García-Toraño, Eduardo; Altzitzoglou, Timotheos; Auerbach, Pavel; Bé, Marie-Martine; Lourenço, Valérie; Bobin, Christophe; Cassette, Philippe; Dersch, Rainer; Kossert, Karsten; Nähle, Ole; Peyrés, Virginia; Pommé, Stefaan; Rozkov, Andrej; Sanchez-Cabezudo, Anabel; Sochoro&vacute; , Jana

    2015-01-01

    An international comparison of the long-lived gamma-ray emitter 129I has been recently completed. A total of 5 laboratories measured a solution prepared by Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT). Aliquots of the master solution were standardized in terms of activity per mass unit by participant laboratories using 4 different techniques. The results of the comparison can be used as the basis for establishing the equivalence among the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Final report of CCQM-K136 measurement of porosity properties (specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous Al2O3

    NASA Astrophysics Data System (ADS)

    Sobina, E.; Zimathis, A.; Prinz, C.; Emmerling, F.; Unger, W.; de Santis Neves, R.; Galhardo, C. E.; De Robertis, E.; Wang, H.; Mizuno, K.; Kurokawa, A.

    2016-01-01

    CCQM key comparison K-136 Measurement of porosity properties (specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous Al2O3 has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The objective of this key comparison is to compare the equivalency of the National Metrology Institutes (NMIs) and Designated Institutes (DIs) for the measurement of specific adsorption, BET specific surface area, specific pore volume and pore diameter) of nanoporous substances (sorbents, catalytic agents, cross-linkers, zeolites, etc) used in advanced technology. In this key comparison, a commercial sorbent (aluminum oxide) was supplied as a sample. Five NMIs participated in this key comparison. All participants used a gas adsorption method, here nitrogen adsorption at 77.3 K, for analysis according to the international standards ISO 15901-2 and 9277. In this key comparison, the degrees of equivalence uncertainties for specific adsorption, BET specific surface area, specific pore volume and pore diameter was established. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report on EURAMET.M.P-S12 — Bilateral supplementary comparison of the national pressure standards of CMI and INRIM in the range 300 Pa to 15 kPa of negative gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajícek, Zdenek; Bergoglio, Mercede; Pražák, Dominik; Pasqualin, Stefano

    2014-01-01

    This report describes a EURAMET bilateral supplementary comparison between Czech CMI and Italian INRIM in low negative gauge pressure in gas (nitrogen), denoted as EURAMET.M.P-S12. The digital non-rotating pressure balance FPG8601 manufactured by Fluke/DH-Instruments, USA is normally used for gauge and absolute pressures in the range from 1 Pa to 15 kPa, but with some modifications it can be used also for the negative gauge pressures in the same range. During the preparation of the visit of INRIM at CMI for the last comparison within the framework of EURAMET.M.P-K4.2010, it was agreed to also perform an additional comparison in the range from 300 Pa to 15 kPa of negative gauge pressure. The measurements were performed in October 2012. Both institutes successfully proved their equivalence in all the tested points in the range from 300 Pa to 15 kPa of negative gauge pressure in a comparison that had, so far, been unique. . Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Applying evidence from economic evaluations to translate cancer survivorship research into care.

    PubMed

    de Moor, Janet S; Alfano, Catherine M; Breen, Nancy; Kent, Erin E; Rowland, Julia

    2015-09-01

    This paper summarizes recommendations stemming from the meeting, Applying Evidence from Economic Evaluations to Translate Cancer Survivorship Research into Care, hosted by the National Cancer Institute. The meeting convened funded investigators, experts in cancer control, survivorship, health economics, and team science to identify the economic and health services data needed to facilitate the dissemination of cancer survivorship interventions into care and how survivorship and health economic investigators can successfully collaborate together and with other stakeholders. Recommendations from the meeting are as follows. First, investigators must engage key stakeholders early in the planning process to understand the outcomes and cost domains on which they base decisions. Second, evaluations of intervention efficacy and value should be conducted using standardized and comparable measures and analytic approaches to enable comparisons across studies. Finally, a health economist should be included during the planning phase of the study so that the economic evaluation is pursued in concert with the survivorship intervention. Economic analyses, from the perspective of key stakeholders, must be incorporated into survivorship intervention research. The results from these analyses should be disseminated in a manner that is transparent, accessible, and comparable across studies. To optimize cancer survivors' health and quality of life, it is essential deliver high-quality and high-value care. Incorporating economic analyses into survivorship intervention research can inform the translation of effective interventions into practice.

  17. Analysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software.

    PubMed

    Rogasch, Nigel C; Sullivan, Caley; Thomson, Richard H; Rose, Nathan S; Bailey, Neil W; Fitzgerald, Paul B; Farzan, Faranak; Hernandez-Pavon, Julio C

    2017-02-15

    The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS-EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS-EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS-EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS-EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS-EEG research. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  18. An Evidence-Based Review of Impacts, Strategies and Tools to Mitigate Urban Heat Islands

    PubMed Central

    Leal Filho, Walter; Echevarria Icaza, Leyre; Emanche, Victoria Omeche; Quasem Al-Amin, Abul

    2017-01-01

    The impacts of climate changes on cities, which are home to over half of the world’s population, are already being felt. In many cases, the intensive speed with which urban centres have been growing means that little attention has been paid to the role played by climatic factors in maintaining quality of life. Among the negative consequences of rapid city growth is the expansion of the problems posed by urban heat islands (UHIs), defined as areas in a city that are much warmer than other sites, especially in comparison with rural areas. This paper analyses the consistency of the UHI-related literature in three stages: first it outlines its characteristics and impacts in a wide variety of cities around the world, which poses pressures to public health in many different countries. Then it introduces strategies which may be employed in order to reduce its effects, and finally it analyses available tools to systematize the initial high level assessment of the phenomenon for multidisciplinary teams involved in the urban planning process. The analysis of literature on the characteristics, impacts, strategies and digital tools to assess on the UHI, reveals the wide variety of parameters, methods, tools and strategies analysed and suggested in the different studies, which does not always allow to compare or standardize the diagnosis or solutions. PMID:29257100

  19. Genome-wide signatures of flowering adaptation to climate temperature: Regional analyses in a highly diverse native range of Arabidopsis thaliana.

    PubMed

    Tabas-Madrid, Daniel; Méndez-Vigo, Belén; Arteaga, Noelia; Marcer, Arnald; Pascual-Montano, Alberto; Weigel, Detlef; Xavier Picó, F; Alonso-Blanco, Carlos

    2018-03-08

    Current global change is fueling an interest to understand the genetic and molecular mechanisms of plant adaptation to climate. In particular, altered flowering time is a common strategy for escape from unfavourable climate temperature. In order to determine the genomic bases underlying flowering time adaptation to this climatic factor, we have systematically analysed a collection of 174 highly diverse Arabidopsis thaliana accessions from the Iberian Peninsula. Analyses of 1.88 million single nucleotide polymorphisms provide evidence for a spatially heterogeneous contribution of demographic and adaptive processes to geographic patterns of genetic variation. Mountains appear to be allele dispersal barriers, whereas the relationship between flowering time and temperature depended on the precise temperature range. Environmental genome-wide associations supported an overall genome adaptation to temperature, with 9.4% of the genes showing significant associations. Furthermore, phenotypic genome-wide associations provided a catalogue of candidate genes underlying flowering time variation. Finally, comparison of environmental and phenotypic genome-wide associations identified known (Twin Sister of FT, FRIGIDA-like 1, and Casein Kinase II Beta chain 1) and new (Epithiospecifer Modifier 1 and Voltage-Dependent Anion Channel 5) genes as candidates for adaptation to climate temperature by altered flowering time. Thus, this regional collection provides an excellent resource to address the spatial complexity of climate adaptation in annual plants. © 2018 John Wiley & Sons Ltd.

  20. Preliminary Results of T and F Asymmetries for KLambda Photoproduction from the Proton

    NASA Astrophysics Data System (ADS)

    Walford, Natalie; Klein, Franz

    2013-04-01

    The search for undiscovered excited states of the nucleon continues to be a focus of experiments at Jefferson Lab. A large effort has been launched using the CLAS detector to provide the database, which will allow nearly model-independent partial wave analyses to be carried out in the search for such states. Polarization observables play a crucial role in this effort, as they are essential in disentangling overlapping resonant and non-resonant amplitudes. Recent coupled-channel analyses [1] have found strong sensitivity of the K-Lambda channel to several higher mass nucleon resonances. In 2010, double-polarization data were taken at JLab using circularly polarized photons incident on a transversely polarized frozen spin target (FROST) [2] comprising butanol, operated at the low temperature of 30mK. The reaction products were detected in CLAS using tagged photons. We will present preliminary data of the T and F asymmetries of the K-Lambda final state with comparisons to predictions of recent multipole analyses. There are very few published measurements of the T asymmetry and none of the F asymmetry for the K-Lambda channel. This work is the first of its kind and will significantly broaden the world database for this reaction.[4pt] [1] A.V. Anisovich et al., Eur. Phys. J. A48 (2012) 15.2] C.D. Keith et al., Nucl. Instr. Meth. A694 (2012) 27.

  1. Trajectories of change in depression severity during treatment with antidepressants.

    PubMed

    Uher, R; Muthén, B; Souery, D; Mors, O; Jaracz, J; Placentino, A; Petrovic, A; Zobel, A; Henigsberg, N; Rietschel, M; Aitchison, K J; Farmer, A; McGuffin, P

    2010-08-01

    Response and remission defined by cut-off values on the last observed depression severity score are commonly used as outcome criteria in clinical trials, but ignore the time course of symptomatic change and may lead to inefficient analyses. We explore alternative categorization of outcome by naturally occurring trajectories of symptom change. Growth mixture models were applied to repeated measurements of depression severity in 807 participants with major depression treated for 12 weeks with escitalopram or nortriptyline in the part-randomized Genome-based Therapeutic Drugs for Depression study. Latent trajectory classes were validated as outcomes in drug efficacy comparison and pharmacogenetic analyses. The final two-piece growth mixture model categorized participants into a majority (75%) following a gradual improvement trajectory and the remainder following a trajectory with rapid initial improvement. The rapid improvement trajectory was over-represented among nortriptyline-treated participants and showed an antidepressant-specific pattern of pharmacogenetic associations. In contrast, conventional response and remission favoured escitalopram and produced chance results in pharmacogenetic analyses. Controlling for drop-out reduced drug differences on response and remission but did not affect latent trajectory results. Latent trajectory mixture models capture heterogeneity in the development of clinical response after the initiation of antidepressants and provide an outcome that is distinct from traditional endpoint measures. It differentiates between antidepressants with different modes of action and is robust against bias due to differential discontinuation.

  2. Supplementary comparison of 500 microgram, 200 microgram, 100 microgram and 50 microgram weights—EURAMET.M.M-S9

    NASA Astrophysics Data System (ADS)

    Davidson, Stuart; Valcu, Adriana; Medina, Nieves; Zuda, Jaroslav; Snopko, Laurenc; Kolozinska, Irena

    2017-01-01

    A comparison of sub-milligram mass standards was undertaken within EURAMET between NPL (as the pilot laboratory), INM (Romania), CEM (Spain), CMI (Czech Republic), SMU (Slovakia) and NSC IM (Ukraine). The weights circulated had nominal values of 500 micrograms, 200 micrograms (2 weights), 100 micrograms and 50 micrograms. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Propane in nitrogen, 1000 μmol/mol

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Pankratov, V. V.; Pankov, A. A.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.; Levbarg, O. S.; Kisel, S. P.; Shpilnyi, S. A.; Yakubov, S. Ye; Bakovec, N. V.; Mironchik, A. M.; Aleksandrov, V. V.

    2017-01-01

    This article presents the report on the COOMET key comparison COOMET.QM-K111, which is linking to the appropriate CCQM comparison—CCQM-K111 'Propane in nitrogen 1000 μmol/mol'. CCQM-K111 was carried out in 2014-2016 and it was one of a series of key comparisons in the gas analysis area assessing core competences. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. NAA For Human Serum Analysis: Comparison With Conventional Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliveira, Laura C.; Zamboni, Cibele B.; Medeiros, Jose A. G.

    2010-08-04

    Instrumental and Comparator methods of Neutron Activation Analysis (NAA) were applied to determine elements of clinical relevancy in serum samples of adult population (Sao Paulo city, Brazil). A comparison with the conventional analyses, Colorimetric for calcium, Titrymetric for chlorine and Ion Specific Electrode for sodium and potassium determination were also performed permitting a discussion about the performance of NAA methods for clinical chemistry research.

  5. Final report on APMP.T-K7.1 key comparison of water triple point cells, bilateral NMIJ-VMI

    NASA Astrophysics Data System (ADS)

    Yamazawa, Kazuaki; Nakano, Tohru; Thanh Binh, Pham

    2018-01-01

    APMP.T-K7.1, was held from July 2014 to May 2015 to compare the national realizations of the water triple point between NMIJ (Japan) and VMI (Vietnam). To reach the objective, VMI sent a transfer cell to NMIJ and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the NMIJ and at the VMI, and aims to link the results of APMP.T-K7.1 to APMP.T-K7 and CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. KEY COMPARISON: Report of the spectral irradiance comparison EURAMET.PR-K1.a.1 between MIKES (Finland) and NIMT (Thailand)

    NASA Astrophysics Data System (ADS)

    Ojanen, M.; Shpak, M.; Kärhä, P.; Leecharoen, R.; Ikonen, E.

    2009-01-01

    A bilateral comparison of the spectral irradiance scales between MIKES (Finland) and NIMT (Thailand) was carried out at 22 wavelengths between 290 nm and 900 nm. MIKES acted as the pilot and link to the results of the key comparison CCPR-K1.a. The spectral irradiance values measured by NIMT generally agree with the key comparison reference value within the expanded uncertainty. The only exceptions are results at wavelengths 300 nm, 450 nm and 500 nm, where the ratios between the degree of equivalence (DoE) and the expanded uncertainty of DoE (k = 2) are 1.0, 1.4 and 1.2, respectively. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. DKIST enclosure modeling and verification during factory assembly and testing

    NASA Astrophysics Data System (ADS)

    Larrakoetxea, Ibon; McBride, William; Marshall, Heather K.; Murga, Gaizka

    2014-08-01

    The Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope, ATST) is unique as, apart from protecting the telescope and its instrumentation from the weather, it holds the entrance aperture stop and is required to position it with millimeter-level accuracy. The compliance of the Enclosure design with the requirements, as of Final Design Review in January 2012, was supported by mathematical models and other analyses which included structural and mechanical analyses (FEA), control models, ventilation analysis (CFD), thermal models, reliability analysis, etc. During the Enclosure Factory Assembly and Testing the compliance with the requirements has been verified using the real hardware and the models created during the design phase have been revisited. The tests performed during shutter mechanism subsystem (crawler test stand) functional and endurance testing (completed summer 2013) and two comprehensive system-level factory acceptance testing campaigns (FAT#1 in December 2013 and FAT#2 in March 2014) included functional and performance tests on all mechanisms, off-normal mode tests, mechanism wobble tests, creation of the Enclosure pointing map, control system tests, and vibration tests. The comparison of the assumptions used during the design phase with the properties measured during the test campaign provides an interesting reference for future projects.

  8. Measurement of the I = 1 / 2 K π S -wave amplitude from Dalitz plot analyses of η c → K K ¯ π in two-photon interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lees, J. P.; Poireau, V.; Tisserand, V.

    Here we study the processes γγ→Kmore » $$0\\atop{S}$$K ±π ∓ and γγ→K +K -π 0 using a data sample of 519 fb -1 recorded with the BABAR detector operating at the SLAC PEP-II asymmetric-energy e +e - collider at center-of-mass energies at and near the Υ(nS) (n=2, 3, 4) resonances. We observe ηc decays to both final states and perform Dalitz plot analyses using a model-independent partial wave analysis technique. This allows a model-independent measurement of the mass-dependence of the I=1/2 Kπ S-wave amplitude and phase. A comparison between the present measurement and those from previous experiments indicates similar behavior for the phase up to a mass of 1.5 GeV/c 2. In contrast, the amplitudes show very marked differences. Lastly, the data require the presence of a new a 0(1950) resonance with parameters m=1931±14±22 MeV/c 2 and Γ=271±22±29 MeV.« less

  9. Modelling exhaust plume mixing in the near field of an aircraft

    NASA Astrophysics Data System (ADS)

    Garnier, F.; Brunet, S.; Jacquin, L.

    1997-11-01

    A simplified approach has been applied to analyse the mixing and entrainment processes of the engine exhaust through their interaction with the vortex wake of an aircraft. Our investigation is focused on the near field, extending from the exit nozzle until about 30 s after the wake is generated, in the vortex phase. This study was performed by using an integral model and a numerical simulation for two large civil aircraft: a two-engine Airbus 330 and a four-engine Boeing 747. The influence of the wing-tip vortices on the dilution ratio (defined as a tracer concentration) shown. The mixing process is also affected by the buoyancy effect, but only after the jet regime, when the trapping in the vortex core has occurred. In the early wake, the engine jet location (i.e. inboard or outboard engine jet) has an important influence on the mixing rate. The plume streamlines inside the vortices are subject to distortion and stretching, and the role of the descent of the vortices on the maximum tracer concentration is discussed. Qualitative comparison with contrail photograph shows similar features. Finally, tracer concentration of inboard engine centreline of B-747 are compared with other theoretical analyses and measured data.

  10. Measurement of the I = 1 / 2 K π S -wave amplitude from Dalitz plot analyses of η c → K K ¯ π in two-photon interactions

    DOE PAGES

    Lees, J. P.; Poireau, V.; Tisserand, V.; ...

    2016-01-20

    Here we study the processes γγ→Kmore » $$0\\atop{S}$$K ±π ∓ and γγ→K +K -π 0 using a data sample of 519 fb -1 recorded with the BABAR detector operating at the SLAC PEP-II asymmetric-energy e +e - collider at center-of-mass energies at and near the Υ(nS) (n=2, 3, 4) resonances. We observe ηc decays to both final states and perform Dalitz plot analyses using a model-independent partial wave analysis technique. This allows a model-independent measurement of the mass-dependence of the I=1/2 Kπ S-wave amplitude and phase. A comparison between the present measurement and those from previous experiments indicates similar behavior for the phase up to a mass of 1.5 GeV/c 2. In contrast, the amplitudes show very marked differences. Lastly, the data require the presence of a new a 0(1950) resonance with parameters m=1931±14±22 MeV/c 2 and Γ=271±22±29 MeV.« less

  11. Regional comparison of absolute gravimeters SIM.M.G-K1 key comparison

    NASA Astrophysics Data System (ADS)

    Newell, D. B.; van Westrum, D.; Francis, O.; Kanney, J.; Liard, J.; Ramirez, A. E.; Lucero, B.; Ellis, B.; Greco, F.; Pistorio, A.; Reudink, R.; Iacovone, D.; Baccaro, F.; Silliker, J.; Wheeler, R. D.; Falk, R.; Ruelke, A.

    2017-01-01

    Twelve absolute gravimeters were compared during the regional Key Comparison SIM.M.G-K1 of absolute gravimeters. The four gravimeters were from different NMIs and DIs. The comparison was linked to the CCM.G-K2 through EURAMET.M.G-K2 via the DI gravimeter FG5X-216. Overall, the results and uncertainties indicate an excellent agreement among the gravimeters, with a standard deviation of the gravimeters' DoEs better than 1.3 μGal. In the case of the official solution, all the gravimeters are in equivalence well within the declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Regional comparison of absolute gravimeters, EURAMET.M.G-K2 key comparison

    NASA Astrophysics Data System (ADS)

    Pálinkáš, V.; Francis, O.; Val'ko, M.; Kostelecký, J.; Van Camp, M.; Castelein, S.; Bilker-Koivula, M.; Näränen, J.; Lothhammer, A.; Falk, R.; Schilling, M.; Timmen, L.; Iacovone, D.; Baccaro, F.; Germak, A.; Biolcati, E.; Origlia, C.; Greco, F.; Pistorio, A.; De Plaen, R.; Klein, G.; Seil, M.; Radinovic, R.; Reudink, R.; Dykowski, P.; Sȩkowski, M.; Próchniewicz, D.; Szpunar, R.; Mojzeš, M.; Jańk, J.; Papčo, J.; Engfeldt, A.; Olsson, P. A.; Smith, V.; van Westrum, D.; Ellis, B.; Lucero, B.

    2017-01-01

    In the framework of the regional EURAMET.M.G-K2 comparison of absolute gravimeters, 17 gravimeters were compared in November 2015. Four gravimeters were from different NMIs and DIs, they were used to link the regional comparison to the CCM.G.K2 by means of linking converter. Combined least-squares adjustments with weighted constraint was used to determine KCRV. Several pilot solutions are presented and compared with the official solution to demonstrate influences of different approaches (e.g. definition of weights and the constraint) on results of the adjustment. In case of the official solution, all the gravimeters are in equivalence with declared uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NSAI-NML (Ireland) and the BIPM

    NASA Astrophysics Data System (ADS)

    Goebel, R.; Power, O.; Fletcher, N.; Stock, M.

    2012-01-01

    This report describes the results obtained from a NML(Ireland)-BIPM bilateral comparison of 10 kΩ resistance standards in 2010. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.b. Two BIPM 10 kΩ travelling standards of SR104 type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standards was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in agreement, with a mean difference smaller than the standard uncertainty of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. 75 FR 65558 - Final Supplemental Environmental Impact Statement, Single Nuclear Unit at the Bellefonte Plant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-25

    ... TENNESSEE VALLEY AUTHORITY Final Supplemental Environmental Impact Statement, Single Nuclear Unit... Environmental Impact Statement for a Single Nuclear Unit at the Bellefonte Plant Site (final SEIS) on September... the ROD. TVA prepared the final SEIS to update the extensive environmental information and analyses...

  15. Final report on APMP supplementary comparison of industrial platinum resistance thermometer for range -50 °C to 400 °C. (APMP.T-S6)

    NASA Astrophysics Data System (ADS)

    Ali, Nurulaini Md; Othman, Hafidzah; Ho, Mong-Kim; Yang, Inseok; Gabi, Victor; Zhang, Zhe; Sheng, Ying; Hu, Jing; Zhang, Jintao; Tsai, Shu-Fei; Liao, Su-Chuion; Shafiqul Alam, Md; Norranim, Uthai; Yaokulbodee, Charuayrat; Liedberg, Hans; Gamal Ahmed, Mohamed; Harba, Naser; Fuad Flaifel, Mustafa; Suherlan; Achmadi, Aditya; Haoyuan, Kho; Yan, Fan; Boon Kwee, Neoh; Thanh Binh, Pham; Ragay, Monalisa

    2017-01-01

    The National Metrology Laboratory, Malaysia (NML-SIRIM) had coordinated the Supplementary Comparison of Industrial Platinum Resistance Thermometer (IPRT) started from July 2009 until April 2011 together with the National Measurement Institute of Australia (NMIA) and Korea Research Institute of Standards and Science (KRISS). This comparison was opened to all APMP members and 16 participants had taken part in order to consolidate or improve their calibration and measurement capabilities (CMCs). Three units of artefacts 100-ohm IPRT belonging to NML-SIRIM, NMIA and KRISS were used and three loops of measurement were run in parallel to shorten the circulation time. The stability of artefacts was monitored with initial and final ice point measurement by each laboratory. The participants need to perform measurement at temperature points (0,-50,-30, 0, 100, 200, 300, 400,0) °C. All submitted data were compiled and adjusted at nominal temperature and by using the linkage from NMIA and KRISS as reference value for all three loops , the temperature deviation from participants from different loops can be compared. The approach of Birge Ratio for final exclusion comprised all the excluded results from the analysis of each loop and the measurement performance for each participant were summarized by the En number value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report on international comparison CCQM-K83: Halocarbons in dry whole air

    NASA Astrophysics Data System (ADS)

    Rhoderick, George; Guenther, Franklin; Duewer, David; Lee, Jeongsoon; Moon, Dongmin; Lee, Jinbok; Lim, Jeongsik; Seog Kim, Jin

    2014-01-01

    The growing awareness of climate change/global warming and continuing concerns regarding stratospheric ozone depletion will require future measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track and control the emissions of these species globally in the atmosphere, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. This report describes the results of a key comparison for several of the more important halocarbons at atmospheric concentration levels. The comparison includes the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC 12), trichlorofluoromethane (CFC 11), and 1,1,2 trichlorotrifluoroethane (CFC 113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC 22) and 1-chloro-1,1-difluoroethane (HCFC 142b); and the hydrofluorocarbon (HFC) 1,1,1,2 tetrafluoroethane (HFC 134a), all in a dried whole air sample. The objective of this key comparison is to compare the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Comparison of the Josephson Voltage Standards of the DMDM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pantelic-Babic, J.; Sofranac, Z.; Cincar Vujovic, T.

    2016-01-01

    A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Directorate of Measures and Precious Metals (DMDM), Belgrade, Serbia, was carried out in June 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the DMDM using its Josephson standard with its own measuring device. Option A required the DMDM to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. Since no sufficiently stable voltage could be achieved in this configuration, a digital detector was used. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 1.5 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. KEY COMPARISON: Final report of the CCQM-K56: Ca, Fe, Zn and Cu in whole fat soybean powder

    NASA Astrophysics Data System (ADS)

    Liandi, Ma; Qian, Wang

    2010-01-01

    The CCQM-K56 key comparison was organized by the Inorganic Analysis Working Group (IAWG) of CCQM as a follow-up to completed pilot study CCQM-P64 to test the abilities of national metrology institutes to measure the amount content of nutritious elements in whole fat soybean powder. A pilot study CCQM-P64.1 was conducted in parallel with this key comparison. The National Institute of Metrology (NIM), P. R. China, acted as the coordinating laboratory. Eleven NIMs participated in CCQM-K56. Four elements - Ca, Fe, Zn and Cu - in different concentration levels have been studied. Different measurement methods (IDMS, ICP-MS, ICP-OES, AAS and INAA) and the microwave digestion method were used. The agreement of the results of CCQM-K56 is very good, and obviously better than that of the original P64. It shows that the capability of all of the participants had been promoted from the original pilot study to this key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. International comparison CCQM-K101: oxygen in nitrogen—a track B comparison and that the matrix contains argon

    NASA Astrophysics Data System (ADS)

    Zhou, Z.; Han, Q.; Wang, D.; Macé, T.; Kipphardt, H.; Maiwald, M.; Tuma, D.; Uehara, S.; Akima, D.; Shimosaka, T.; Jung, J.; Oh, S.-H.; van der Veen, A.; van Wijk, J. I. T.; Ziel, P. R.; Konopelko, L.; Valkova, M.; Mogale, David M.; Botha, A.; Brewer, P.; Murugan, A.; Doval Minnaro, M.; Miller, M.; Guenther, F.; Kelly, M. E.

    2016-01-01

    This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Aerobic power and field test results of amateur 15-a-side rugby union players.

    PubMed

    Sant'anna, Ricardo T; de Souza Castro, Flávio A

    2017-12-01

    The aim of the present study was to verify whether it is possible to predict aerobic power in amateur 15-a-side rugby union players through the Yo-Yo Intermittent Recovery Test Level 1 (Yo-Yo IRT1) and the 5-meter Multiple Shuttle Test (5-m MST). Forty-two amateur players - 22 forwards and 20 backs - were evaluated in three phases: 1) maximum treadmill test in the laboratory; 2) field test set by a drawing in the first phase; and 3) second field test. Descriptive, comparison, correlation, regression and level of agreement analyses were performed. Backs, when compared to forwards, showed a higher VO2max (61.7±15 mL/kg/min and 51.6±10.1 mL/kg/min, respectively), Yo-Yo IRT1 final level (16.4±0.8 and 14.9±0.9, respectively) and Yo-Yo IRT1 total distance (1283.3±312.5 m and 792±277.6 m, respectively), and a higher final distance in the 5-m MST (686.8±36.6 and 642.9±46.5, respectively). Significant correlations were found between the result and the total distance on the Yo-Yo IRT1 and the VO2max (r=0.425 and r=0.459, respectively). Using the total distance covered in the Yo-Yo IRT1, the VO2max of amateur 15-a-side rugby union players can be estimated through the equation VO2max = 0.016 × (DIST Yo‑Yo) + 40.578. Yo-Yo IRT1 is most useful when the objective is to evaluate the aerobic power of amateur RU players in comparison with the 5-m MST.

  1. Modelisation de l'historique d'operation de groupes turbine-alternateur

    NASA Astrophysics Data System (ADS)

    Szczota, Mickael

    Because of their ageing fleet, the utility managers are increasingly in needs of tools that can help them to plan efficiently maintenance operations. Hydro-Quebec started a project that aim to foresee the degradation of their hydroelectric runner, and use that information to classify the generating unit. That classification will help to know which generating unit is more at risk to undergo a major failure. Cracks linked to the fatigue phenomenon are a predominant degradation mode and the loading sequences applied to the runner is a parameter impacting the crack growth. So, the aim of this memoir is to create a generator able to generate synthetic loading sequences that are statistically equivalent to the observed history. Those simulated sequences will be used as input in a life assessment model. At first, we describe how the generating units are operated by Hydro-Quebec and analyse the available data, the analysis shows that the data are non-stationnary. Then, we review modelisation and validation methods. In the following chapter a particular attention is given to a precise description of the validation and comparison procedure. Then, we present the comparison of three kind of model : Discrete Time Markov Chains, Discrete Time Semi-Markov Chains and the Moving Block Bootstrap. For the first two models, we describe how to take account for the non-stationnarity. Finally, we show that the Markov Chain is not adapted for our case, and that the Semi-Markov chains are better when they include the non-stationnarity. The final choice between Semi-Markov Chains and the Moving Block Bootstrap depends of the user. But, with a long term vision we recommend the use of Semi-Markov chains for their flexibility. Keywords: Stochastic models, Models validation, Reliability, Semi-Markov Chains, Markov Chains, Bootstrap

  2. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the BIM (Bulgaria) and the BIPM

    NASA Astrophysics Data System (ADS)

    Rolland, B.; Fletcher, N.; Tenev, A.; Hadzhistoykova, R.

    2017-01-01

    This report gives the result of a bilateral comparison of resistance between the BIM (Bulgaria) and the BIPM carried out in 2013. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the BIM, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ). The results from the BIM and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95% confidence, k = 2) of 0.30 × 10-6 at 10 kΩ and in reasonable agreement for 1 Ω with a relative difference of -0.18 × 10-6 with a relative expanded uncertainty of 0.17 × 10-6. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on EURAMET.M.P-K4.2010: Key and supplementary comparison of national pressure standards in the range 1 Pa to 15 kPa of absolute and gauge pressure

    NASA Astrophysics Data System (ADS)

    Krajíček, Zdeněk; Bergoglio, Mercede; Jousten, Karl; Otal, Pierre; Sabuga, Wladimir; Saxholm, Sari; Pražák, Dominik; Vičar, Martin

    2014-01-01

    This report describes a EURAMET comparison of five European National Metrology Institutes in low gauge and absolute pressure in gas (nitrogen), denoted as EURAMET.M.P-K4.2010. Its main intention is to state equivalence of the pressure standards, in particular those based on the technology of force-balanced piston gauges such as e.g. FRS by Furness Controls, UK and FPG8601 by DHI-Fluke, USA. It covers the range from 1 Pa to 15 kPa, both gauge and absolute. The comparison in absolute mode serves as a EURAMET Key Comparison which can be linked to CCM.P-K4 and CCM.P-K2 via PTB. The comparison in gauge mode is a supplementary comparison. The comparison was carried out from September 2008 till October 2012. The participating laboratories were the following: CMI, INRIM, LNE, MIKES, PTB-Berlin (absolute pressure 1 kPa and below) and PTB-Braunschweig (absolute pressure 1 kPa and above and gauge pressure). CMI was the pilot laboratory and provided a transfer standard for the comparison. This transfer standard was also the laboratory standard of CMI at the same time, which resulted in a unique and logistically difficult star comparison. Both in gauge and absolute pressures all the participating institutes successfully proved their equivalence with respect to the reference value and all also proved mutual bilateral equivalences in all the points. All the participating laboratories are also equivalent with the reference values of CCM.P-K4 and CCM.P-K2 in the relevant points. The comparison also proved the ability of FPG8601 to serve as a transfer standard. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2012-01-01

    As part of the on-going BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from February to March 2012. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_C (ZC) and BIPM_D (ZD), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson voltage standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 February 2012. UNML - UBIPM = +0.83 µV, uc = 1.35 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. The final result is impacted by the anomalous offset between the NSAI-NML results for the two transfer standards. The reason for this offset hasn't been determined. However, the difference remains within the total combined standard uncertainty. Therefore, the comparison result shows that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. The effect of Tai Chi on four chronic conditions-cancer, osteoarthritis, heart failure and chronic obstructive pulmonary disease: a systematic review and meta-analyses.

    PubMed

    Chen, Yi-Wen; Hunt, Michael A; Campbell, Kristin L; Peill, Kortni; Reid, W Darlene

    2016-04-01

    Many middle-aged and older persons have more than one chronic condition. Thus, it is important to synthesise the effectiveness of interventions across several comorbidities. The aim of this systematic review was to summarise current evidence regarding the effectiveness of Tai Chi in individuals with four common chronic conditions-cancer, osteoarthritis (OA), heart failure (HF) and chronic obstructive pulmonary disease (COPD). 4 databases (MEDLINE, EMBASE, CINAHL and SPORTDiscus) were searched for original articles. Two reviewers independently screened the titles and abstracts and then conducted full-text reviews, quality assessment and finally data abstraction. 33 studies met the inclusion criteria. Meta-analyses were performed on disease-specific symptoms, physiological outcomes and physical performance of each chronic condition. Subgroup analyses on disease-specific symptoms were conducted by categorising studies into subsets based on the type of comparison groups. Meta-analyses showed that Tai Chi improved or showed a tendency to improve physical performance outcomes, including 6-min walking distance (6MWD) and knee extensor strength, in most or all four chronic conditions. Tai Chi also improved disease-specific symptoms of pain and stiffness in OA. The results demonstrated a favourable effect or tendency of Tai Chi to improve physical performance and showed that this type of exercise could be performed by individuals with different chronic conditions, including COPD, HF and OA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. APMP comparison on luminous flux units (APMP.PR-K4)

    NASA Astrophysics Data System (ADS)

    Liu, H.; Lin, Y. D.; Yang, C. Z.; Yu, J.

    2018-01-01

    During the 18th APMP meeting in 2004, TCPR agreed that the luminous flux should be one of the several regional comparisons to be conducted in the field of photometry and radiometry, and the project was named as APMP.PR-K4. Nine laboratories took part in this comparison. A group of LF 200W lamps (no less than three) was used as transfer artifacts by each participant. The National Institute of Metrology (NIM, China) acted as the pilot laboratory. Presented in this report are the detailed procedures and results of the work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Statistics attack on `quantum private comparison with a malicious third party' and its improvement

    NASA Astrophysics Data System (ADS)

    Gu, Jun; Ho, Chih-Yung; Hwang, Tzonelih

    2018-02-01

    Recently, Sun et al. (Quantum Inf Process:14:2125-2133, 2015) proposed a quantum private comparison protocol allowing two participants to compare the equality of their secrets via a malicious third party (TP). They designed an interesting trap comparison method to prevent the TP from knowing the final comparison result. However, this study shows that the malicious TP can use the statistics attack to reveal the comparison result. A simple modification is hence proposed to solve this problem.

  10. Economic evaluations of angiotensin-converting enzyme inhibitors and angiotensin II receptor blockers in type 2 diabetic nephropathy: a systematic review

    PubMed Central

    2014-01-01

    Background Structured comparison of pharmacoeconomic analyses for ACEIs and ARBs in patients with type 2 diabetic nephropathy is still lacking. This review aims to systematically review the cost-effectiveness of both ACEIs and ARBs in type 2 diabetic patients with nephropathy. Methods A systematic literature search was performed in MEDLINE and EMBASE for the period from November 1, 1999 to Oct 31, 2011. Two reviewers independently assessed the quality of the articles included and extracted data. All cost-effectiveness results were converted to 2011 Euros. Results Up to October 2011, 434 articles were identified. After full-text checking and quality assessment, 30 articles were finally included in this review involving 39 study settings. All 6 ACEIs studies were literature-based evaluations which synthesized data from different sources. Other 33 studies were directed at ARBs and were designed based on specific trials. The Markov model was the most common decision analytic method used in the evaluations. From the cost-effectiveness results, 37 out of 39 studies indicated either ACEIs or ARBs were cost-saving comparing with placebo/conventional treatment, such as amlodipine. A lack of evidence was assessed for valid direct comparison of cost-effectiveness between ACEIs and ARBs. Conclusion There is a lack of direct comparisons of ACEIs and ARBs in existing economic evaluations. Considering the current evidence, both ACEIs and ARBs are likely cost-saving comparing with conventional therapy, excluding such RAAS inhibitors. PMID:24428868

  11. Reliability and Validity of Nonsymbolic and Symbolic Comparison Tasks in School-Aged Children.

    PubMed

    Castro, Danilka; Estévez, Nancy; Gómez, David; Dartnell, Pablo Ricardo

    2017-12-04

    Basic numerical processing has been regularly assessed using numerical nonsymbolic and symbolic comparison tasks. It has been assumed that these tasks index similar underlying processes. However, the evidence concerning the reliability and convergent validity across different versions of these tasks is inconclusive. We explored the reliability and convergent validity between two numerical comparison tasks (nonsymbolic vs. symbolic) in school-aged children. The relations between performance in both tasks and mental arithmetic were described and a developmental trajectories' analysis was also conducted. The influence of verbal and visuospatial working memory processes and age was controlled for in the analyses. Results show significant reliability (p < .001) between Block 1 and 2 for nonsymbolic task (global adjusted RT (adjRT): r = .78, global efficiency measures (EMs): r = .74) and, for symbolic task (adjRT: r = .86, EMs: r = .86). Also, significant convergent validity between tasks (p < .001) for both adjRT (r = .71) and EMs (r = .70) were found after controlling for working memory and age. Finally, it was found the relationship between nonsymbolic and symbolic efficiencies varies across the sample's age range. Overall, these findings suggest both tasks index the same underlying cognitive architecture and are appropriate to explore the Approximate Number System (ANS) characteristics. The evidence supports the central role of ANS in arithmetic efficiency and suggests there are differences across the age range assessed, concerning the extent to which efficiency in nonsymbolic and symbolic tasks reflects ANS acuity.

  12. AC Power at Power Frequencies: Bilateral comparison between SASO NMCC and TÜBİTAK UME

    NASA Astrophysics Data System (ADS)

    Çaycı, Hüseyin; Yılmaz, Özlem; AlRobaish, Abdullah M.; AlAnazi, Shafi S.; AlAyali, Ahmed R.; AlRumie, Rashed A.

    2018-01-01

    A supplementary bilateral comparison measurement on AC Power at 50/60 Hz between SASO NMCC (GULFMET) and TÜBİTAK UME (EURAMET) was performed with the primary power standards of each partner. Measurement methods and setups which are very similar of the participants, measurement results, calculation of differences in the results, evaluation of uncertainties are given within this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Sewage sludge conditioning with the application of ash from biomass-fired power plant

    NASA Astrophysics Data System (ADS)

    Wójcik, Marta; Stachowicz, Feliks; Masłoń, Adam

    2018-02-01

    During biomass combustion, there are formed combustion products. Available data indicates that only 29.1 % of biomass ashes were recycled in Poland in 2013. Chemical composition and sorptive properties of ashes enable their application in the sewage sludge treatment. This paper analyses the impact of ashes from biomass-combustion power plant on sewage sludge dewatering and higienisation. The results obtained in laboratory tests proved the possitive impact of biomass ashes on sewage sludge hydration reduction after dewatering and the increase of filtrate volume. After sludge conditioning with the use of biomass combustion by-products, the final moisture content decreased by approximatelly 10÷25 % in comparison with raw sewage sludge depending on the method of dewatering. The application of biomass combustion products in sewage sludge management could provide an alternative method of their utilization according to law and environmental requirements.

  14. Subsystem Analysis/Optimization for the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    McDonald, J. P.; Hedayat, A.; Brown, T. M.; Knight, K. C.; Champion, R. H., Jr.

    1998-01-01

    The Orbital Sciences Corporation X-34 vehicle demonstrates technologies and operations key to future reusable launch vehicles. The general flight performance goal of this unmanned rocket plane is Mach 8 flight at an altitude of 250,000 feet. The Main Propulsion System (MPS) supplies liquid propellants to the main engine, which provides the primary thrust for attaining mission goals. Major MPS design and operational goals are aircraft-like ground operations, quick turnaround between missions, and low initial/operational costs. Analyses related to optimal MPS subsystem design are reviewed in this paper. A pressurization system trade weighs maintenance/reliability concerns against those for safety in a comparison of designs using pressure regulators versus orifices to control pressurant flow. A propellant dump/feed system analysis weighs the issues of maximum allowable vehicle landing weight, trajectory, and MPS complexity to arrive at a final configuration for propellant dump/feed systems.

  15. A green approach toward quinoxalines and bis-quinoxalines and their biological evaluation against A431, human skin cancer cell lines.

    PubMed

    Bandyopadhyay, Debasish; Cruz, Jessica; Morales, Liza D; Arman, Hadi D; Cuate, Erica; Lee, Young S; Banik, Bimal K; Kim, Dae J

    2013-08-01

    The objective of this study was to develop a practical green procedure to synthesize quinoxalines and bis-quinoxalines and evaluate their inhibitory effects on the viability of A431 human epidermoid carcinoma cells. A series of quinoxaline and bis-quinoxaline derivatives have been designed and synthesized following a microwave-assisted and bismuth nitrate-catalyzed eco-friendly route. A detailed comparison has been made between microwave-induced protocol with the reactions occurred at room temperature. The structure of the compounds have been elucidated by various spectroscopic methods and finally confirmed by x-ray crystallographic analyses. Two quinoxaline derivatives, compounds 6 and 12 have demonstrated inhibitory effects on the viability of A431 human epidermoid carcinoma cells when compared with HaCaT nontumorigenic human keratinocyte cells. Notably, compound 6 inhibits Stat3 phosphorylation/activation in A431 skin cancer cells.

  16. “Feeling Disorder” as a Comparative and Contingent Process: Gender, Neighborhood Conditions, and Adolescent Mental Health*

    PubMed Central

    Browning, Christopher R.; Soller, Brian; Gardner, Margo; Brooks-Gunn, Jeanne

    2017-01-01

    We explore the effects of neighborhood social disorder on internalizing symptoms among urban youth, focusing on three questions: First, we ask whether the impact of social disorder on internalizing symptoms results from comparisons to conditions measured locally or across the entire city. Second, we consider whether neighborhood collective efficacy modifies disorder’s effect on internalizing symptoms. Finally, we assess whether these effects vary by gender. Analyses of survey data of 2,367 youth from the Project on Human Development in Chicago Neighborhoods indicate social disorder is positively associated with girls’ internalizing symptoms when measured as a deviation from a “neighborhood cluster” (2–3 census tracts) mean. High collective efficacy within girls’ neighborhood cluster attenuates disorder effects on their internalizing symptoms. We find no evidence of disorder or collective efficacy effects on boys’ internalizing symptoms. PMID:24026534

  17. Hybrid organic semiconductor lasers for bio-molecular sensing.

    PubMed

    Haughey, Anne-Marie; Foucher, Caroline; Guilhabert, Benoit; Kanibolotsky, Alexander L; Skabara, Peter J; Burley, Glenn; Dawson, Martin D; Laurand, Nicolas

    2014-01-01

    Bio-functionalised luminescent organic semiconductors are attractive for biophotonics because they can act as efficient laser materials while simultaneously interacting with molecules. In this paper, we present and discuss a laser biosensor platform that utilises a gain layer made of such an organic semiconductor material. The simple structure of the sensor and its operation principle are described. Nanolayer detection is shown experimentally and analysed theoretically in order to assess the potential and the limits of the biosensor. The advantage conferred by the organic semiconductor is explained, and comparisons to laser sensors using alternative dye-doped materials are made. Specific biomolecular sensing is demonstrated, and routes to functionalisation with nucleic acid probes, and future developments opened up by this achievement, are highlighted. Finally, attractive formats for sensing applications are mentioned, as well as colloidal quantum dots, which in the future could be used in conjunction with organic semiconductors.

  18. Analysis and comparison of NoSQL databases with an introduction to consistent references in big data storage systems

    NASA Astrophysics Data System (ADS)

    Dziedzic, Adam; Mulawka, Jan

    2014-11-01

    NoSQL is a new approach to data storage and manipulation. The aim of this paper is to gain more insight into NoSQL databases, as we are still in the early stages of understanding when to use them and how to use them in an appropriate way. In this submission descriptions of selected NoSQL databases are presented. Each of the databases is analysed with primary focus on its data model, data access, architecture and practical usage in real applications. Furthemore, the NoSQL databases are compared in fields of data references. The relational databases offer foreign keys, whereas NoSQL databases provide us with limited references. An intermediate model between graph theory and relational algebra which can address the problem should be created. Finally, the proposal of a new approach to the problem of inconsistent references in Big Data storage systems is introduced.

  19. Novel aldehyde and thiosemicarbazone derivatives: Synthesis, spectroscopic characterization, structural studies and molecular docking studies

    NASA Astrophysics Data System (ADS)

    Karakurt, Tuncay; Tahtaci, Hakan; Subasi, Nuriye Tuna; Er, Mustafa; Ağar, Erbil

    2016-12-01

    In this study our purpose is that, synthesis and characterization of compounds containing the aldehyde and thiosemicarbazone groups and comparison of the theoretical results with the experimental results. The structures of all synthesized compounds were elucidated by IR, 1H NMR, 13C NMR, elemental analyses techniques. The structure of compound (4) (C9H8N4O2S) was also elucidated by X-ray diffraction analysis. In addition, the theoretical IR spectrum, 1H NMR and 13C NMR chemical shift values, frontier molecular orbital values (FMO) of these molecules were analyzed by using Becke-3- Lee-Yang-Parr (B3LYP) method with LanL2DZ basis set. Finally, molecular docking studies were performed on synthesized compounds using the 4DKI beta-lactam protein structure to determine the potential binding mode of inhibitors.

  20. On Some Methods in Safety Evaluation in Geotechnics

    NASA Astrophysics Data System (ADS)

    Puła, Wojciech; Zaskórski, Łukasz

    2015-06-01

    The paper demonstrates how the reliability methods can be utilised in order to evaluate safety in geotechnics. Special attention is paid to the so-called reliability based design that can play a useful and complementary role to Eurocode 7. In the first part, a brief review of first- and second-order reliability methods is given. Next, two examples of reliability-based design are demonstrated. The first one is focussed on bearing capacity calculation and is dedicated to comparison with EC7 requirements. The second one analyses a rigid pile subjected to lateral load and is oriented towards working stress design method. In the second part, applications of random field to safety evaluations in geotechnics are addressed. After a short review of the theory a Random Finite Element algorithm to reliability based design of shallow strip foundation is given. Finally, two illustrative examples for cohesive and cohesionless soils are demonstrated.

  1. Contribution to the application of two-colour imaging to diesel combustion

    NASA Astrophysics Data System (ADS)

    Payri, F.; Pastor, J. V.; García, J. M.; Pastor, J. M.

    2007-08-01

    The two-colour method (2C) is a well-known methodology for the estimation of flame temperature and the soot-related KL factor. A 2C imaging system has been built with a single charge-coupled device (CCD) camera for visualization of the diesel flame in a single-cylinder 2-stroke engine with optical accesses. The work presented here focuses on methodological aspects. In that sense, the influence of calibration uncertainties on the measured temperature and KL factor has been analysed. Besides, a theoretical study is presented that tries to link the true flame temperature and soot distributions with those derived from the 2C images. Finally, an experimental study has been carried out in order to show the influence of injection pressure, air density and temperature on the 2C-derived parameters. Comparison with the expected results has shown the limitations of this methodology for diesel flame analysis.

  2. Effect of a 6-Week Active Play Intervention on Fundamental Movement Skill Competence of Preschool Children.

    PubMed

    Foulkes, J D; Knowles, Z; Fairclough, S J; Stratton, G; O'Dwyer, M; Ridgers, N D; Foweather, L

    2017-04-01

    This study examined the effectiveness of an active play intervention on fundamental movement skills of 3- to 5-year-old children from deprived communities. In a cluster randomized controlled trial design, six preschools received a resource pack and a 6-week local authority program involving staff training with help implementing 60-minute weekly sessions and postprogram support. Six comparison preschools received a resource pack only. Twelve skills were assessed at baseline, postintervention, and at a 6-month follow-up using the Children's Activity and Movement in Preschool Study Motor Skills Protocol. One hundred and sixty-two children (Mean age = 4.64 ± 0.58 years; 53.1% boys) were included in the final analyses. There were no significant differences between groups for total fundamental movement skill, object-control skill or locomotor skill scores, indicating a need for program modification to facilitate greater skill improvements.

  3. An introduction to using Bayesian linear regression with clinical data.

    PubMed

    Baldwin, Scott A; Larson, Michael J

    2017-11-01

    Statistical training psychology focuses on frequentist methods. Bayesian methods are an alternative to standard frequentist methods. This article provides researchers with an introduction to fundamental ideas in Bayesian modeling. We use data from an electroencephalogram (EEG) and anxiety study to illustrate Bayesian models. Specifically, the models examine the relationship between error-related negativity (ERN), a particular event-related potential, and trait anxiety. Methodological topics covered include: how to set up a regression model in a Bayesian framework, specifying priors, examining convergence of the model, visualizing and interpreting posterior distributions, interval estimates, expected and predicted values, and model comparison tools. We also discuss situations where Bayesian methods can outperform frequentist methods as well has how to specify more complicated regression models. Finally, we conclude with recommendations about reporting guidelines for those using Bayesian methods in their own research. We provide data and R code for replicating our analyses. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Quantitative proteomics in biological research.

    PubMed

    Wilm, Matthias

    2009-10-01

    Proteomics has enabled the direct investigation of biological material, at first through the analysis of individual proteins, then of lysates from cell cultures, and finally of extracts from tissues and biopsies from entire organisms. Its latest manifestation - quantitative proteomics - allows deeper insight into biological systems. This article reviews the different methods used to extract quantitative information from mass spectra. It follows the technical developments aimed toward global proteomics, the attempt to characterize every expressed protein in a cell by at least one peptide. When applications of the technology are discussed, the focus is placed on yeast biology. In particular, differential quantitative proteomics, the comparison between an experiment and its control, is very discriminating for proteins involved in the process being studied. When trying to understand biological processes on a molecular level, differential quantitative proteomics tends to give a clearer picture than global transcription analyses. As a result, MS has become an even more indispensable tool for biochemically motivated biological research.

  5. Data analysis and archival

    NASA Technical Reports Server (NTRS)

    Danielsen, Edwin F.; Pfister, Leonhard; Hipskind, R. Stephen; Gaines, Steven E.

    1990-01-01

    The purpose of this task is the acquisition, distribution, archival, and analysis of data collected during and in support of the Upper Atmospheric Research Program (UARP) field experiments. Meteorological and U2 data from the 1984 Stratosphere-Troposphere Exchange Project (STEP) was analyzed to determine characteristics of internal atmospheric waves. CDROM's containing data from the 1987 STEP, 1987 Airborne Antarctic Ozone Expedition (AAOE), and the 1989 Airborne Arctic Stratospheric Expedition (AASE) were produced for archival and distribution of those data sets. The AASE CDROM contains preliminary data and a final release is planned for February 1990. Comparisons of data from the NASA ER-2 Meteorological Measurement System (MMS) with radar tracking and radiosonde data show good agreement. Planning for a Meteorological Support Facility continues. We are investigating existing and proposed hardware and software to receive, manipulate, and display satellite imagery and standard meteorological analyses, forecasts, and radiosonde data.

  6. Validation/Calibration of SMOS L2 Soil Moisture in Crop Area, Eastern China

    NASA Astrophysics Data System (ADS)

    Cui, Huizhen; Jiang, Lingmei; Yang, Na; Lu, Zheng

    2016-08-01

    The Soil Moisture and Ocean Salinity (SMOS) is the worldwide satellite dedicated to retrieve soil moisture information at the global scale, with a high temporal resolution, and from space borne L-band 2-D interferometry radiometer. Product validation for the accuracy of data and utilization is a crucial step. At present, the validation work carried out in China was mainly concentrated in the Tibetan Plateau. The study of this paper mainly focused on the validation of SMOS L2 soil moisture data products in the north of Henan province plain region. This region is in front of Taihang Mountains. Results from the average-average and node- site comparison show that the correlation coefficients (R) between 0.20 and 0.40, also the existence of dry bias mainly concentrated in the 0.07 0.11m3m-3. Finally, this paper analysed the influence factors on the quality of SMOS soil moisture products.

  7. In vitro evidence for RNA binding properties of the coat protein of prunus necrotic ringspot ilarvirus and their comparison to related and unrelated viruses.

    PubMed

    Pallás, V; Sánchez-Navarro, J A; Díez, J

    1999-01-01

    The RNA binding properties of the prunus necrotic ringspot virus (PNRSV) coat protein (CP) were demonstrated by northwestern and dot-blot analyses. The capability to bind PNRSV RNA 4 was compared with viruses representing three different interactions prevailing in the assembly and architecture of virions. The results showed that cucumber mosaic virus (CMV) and PNRSV CPs, which stabilise their virions mainly through RNA-protein interactions bound PNRSV RNA 4 even at very high salt concentrations. The CP of cherry leaf roll nepovirus, whose virions are predominantly stabilised by protein-protein interactions did not bind even at the lowest salt concentration tested. Finally the CP of carnation mottle carmovirus, that has an intermediate position in which both RNA-protein and protein-protein interactions are equally important showed a salt-dependent RNA binding.

  8. A Comparison of Attitudes and Final Grades among Freshman Dental Students.

    ERIC Educational Resources Information Center

    Lee, Mickey M.; And Others

    1981-01-01

    A study examined students' change in attitudes toward dental education, themselves, and gross anatomy based on their experience in a difficult anatomy course and their final grades. Change occurred only in their attitudes about dental education, but it is concluded that specific aspects of the environment can be used to predict a final grade. (MSE)

  9. Feedback on students' clinical reasoning skills during fieldwork education

    PubMed Central

    de Beer, Marianne; Mårtensson, Lena

    2015-01-01

    Background/aim Feedback on clinical reasoning skills during fieldwork education is regarded as vital in occupational therapy students' professional development. The nature of supervisors' feedback however, could be confirmative and/or corrective and corrective feedback could be with or without suggestions on how to improve. The aim of the study was to evaluate the impact of supervisors' feedback on final-year occupational therapy students' clinical reasoning skills through comparing the nature of feedback with the students' subsequent clinical reasoning ability. Method A mixed-method approach with a convergent parallel design was used combining the collection and analysis of qualitative and quantitative data. From focus groups and interviews with students, data were collected and analysed qualitatively to determine how the students experienced the feedback they received from their supervisors. By quantitatively comparing the final practical exam grades with the nature of the feedback, their fieldwork End-of-Term grades and average academic performance it became possible to merge the results for comparison and interpretation. Results Students' clinical reasoning skills seem to be improved through corrective feedback if accompanied by suggestions on how to improve, irrespective of their average academic performance. Supervisors were inclined to underrate high performing students and overrate lower performing students. Conclusions Students who obtained higher grades in the final practical examinations received more corrective feedback with suggestions on how to improve from their supervisors. Confirmative feedback alone may not be sufficient for improving the clinical reasoning skills of students. PMID:26256854

  10. Spontaneous strategy use in children with autism spectrum disorder: the roles of metamemory and language skills

    PubMed Central

    Bebko, James M.; Rhee, Thomas; McMorris, Carly A.; Ncube, Busisiwe L.

    2015-01-01

    Metamemory, or beliefs about one’s own memory capabilities, knowing what you know, and knowing what you don’t know, has frequently been linked to the spontaneous use of rehearsal strategies in typically developing children. However, limited research has investigated mnemonic strategy use, metamemory, or the relationship between these two cognitive processes in children with autism spectrum disorders (ASDs). The current study examined the relative strength of metamemory knowledge and language skills as predictors of rehearsal use and memory performance in individuals with ASD. Twenty-one children with ASD and 21 children in a combined comparison group were matched on chronological and verbal mental age. Over two sessions, participants completed a serial recall task, a language measure, and a metamemory questionnaire. Children were classified as rehearsers/non-rehearsers based on behavioral observations and/or verbal reports of strategy use. As expected from previous research, the comparison group had a significantly higher proportion of rehearsers than the ASD group. However, spontaneous rehearsers performed significantly better on the serial recall task than non-rehearsers, regardless of group membership. Children in the comparison group had a higher mean total score on the metamemory questionnaire than the ASD group. However, when examined by rehearsal use, participants classified as rehearsers, regardless of diagnostic group, scored significantly higher on the metamemory questionnaire than non-rehearsers. Finally, across groups, hierarchical regression analyses identified both metamemory and language proficiency as significant predictors of rehearsal strategy use. The fact that the predictors showed the same relationship across the comparison group and the ASD group implies that metamemory and language proficiency, while separate entities, are both fundamental underlying skills contributing to the emergence of rehearsal strategies, and that the results are likely generalizable to other populations with developmental challenges. PMID:25788890

  11. Galaxy Cluster Mass Reconstruction Project - II. Quantifying scatter and bias using contrasting mock catalogues

    DOE PAGES

    Old, L.; Wojtak, R.; Mamon, G. A.; ...

    2015-03-26

    Our paper is the second in a series in which we perform an extensive comparison of various galaxy-based cluster mass estimation techniques that utilize the positions, velocities and colours of galaxies. Our aim is to quantify the scatter, systematic bias and completeness of cluster masses derived from a diverse set of 25 galaxy-based methods using two contrasting mock galaxy catalogues based on a sophisticated halo occupation model and a semi-analytic model. Analysing 968 clusters, we find a wide range in the rms errors in log M200c delivered by the different methods (0.18–1.08 dex, i.e. a factor of ~1.5–12), with abundance-matchingmore » and richness methods providing the best results, irrespective of the input model assumptions. In addition, certain methods produce a significant number of catastrophic cases where the mass is under- or overestimated by a factor greater than 10. Given the steeply falling high-mass end of the cluster mass function, we recommend that richness- or abundance-matching-based methods are used in conjunction with these methods as a sanity check for studies selecting high-mass clusters. We also see a stronger correlation of the recovered to input number of galaxies for both catalogues in comparison with the group/cluster mass, however, this does not guarantee that the correct member galaxies are being selected. Finally, we did not observe significantly higher scatter for either mock galaxy catalogues. These results have implications for cosmological analyses that utilize the masses, richnesses, or abundances of clusters, which have different uncertainties when different methods are used.« less

  12. Can oral 5-aminosalicylic acid be administered once daily in the treatment of mild-to-moderate ulcerative colitis? A meta-analysis of randomized-controlled trials.

    PubMed

    Zhu, Ying; Tang, Ren-Kuan; Zhao, Peng; Zhu, Shi-sheng; Li, Yong-guo; Li, Jian-bo

    2012-05-01

    Several trials have demonstrated that oral delayed-release mesalamine might be administered once daily. We aimed to conduct a meta-analysis to investigate this. A comprehensive and multiple-source literature search was carried out. Only randomized-controlled trials (RCTs) were investigated by comparing a once daily-dosing regime with a divided (twice or thrice daily)-dosing regime of oral delayed-release mesalamine formulations for induction or maintenance of remission in patients with mild-to-moderate ulcerative colitis. The quality of RCTs was assessed using the Jadad scores. Meta-analysis of pooled odds ratios was carried out using Review Manager 5.1. Nine RCTs were finally included. With regard to meta-analyses for induction trials, there were no significant differences for all comparisons between the once daily and the divided groups, including maintenance of just clinical remission (P=0.52) and just endoscopic remission (P=0.23), maintenance of combined clinical and endoscopic remission (P=0.78), and the overall incidence of adverse events (P=0.61). With regard to meta-analyses for maintenance trials, there were also no significant differences for all comparisons between once daily and divided groups, including maintenance of just clinical remission (P=0.73) and just endoscopic remission (P=0.43), maintenance of combined clinical and endoscopic remission (P=0.43), the overall incidence of adverse events (P=0.12) as well as compliance with the prescribed medication (P=0.34). The present work showed that oral delayed-release mesalazine administered as a single or a divided dose demonstrated a good safety profile, which was well tolerated and effective as either maintenance or induction treatment. High clinical and/or endoscopic remission rates can be achieved with once-daily dosing.

  13. Measurement Equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS®) Pain Interference Short Form Items: Application to Ethnically Diverse Cancer and Palliative Care Populations.

    PubMed

    Teresi, Jeanne A; Ocepek-Welikson, Katja; Cook, Karon F; Kleinman, Marjorie; Ramirez, Mildred; Reid, M Carrington; Siu, Albert

    2016-01-01

    Reducing the response burden of standardized pain measures is desirable, particularly for individuals who are frail or live with chronic illness, e.g., those suffering from cancer and those in palliative care. The Patient Reported Outcome Measurement Information System ® (PROMIS ® ) project addressed this issue with the provision of computerized adaptive tests (CAT) and short form measures that can be used clinically and in research. Although there has been substantial evaluation of PROMIS item banks, little is known about the performance of PROMIS short forms, particularly in ethnically diverse groups. Reviewed in this article are findings related to the differential item functioning (DIF) and reliability of the PROMIS pain interference short forms across diverse sociodemographic groups. DIF hypotheses were generated for the PROMIS short form pain interference items. Initial analyses tested item response theory (IRT) model assumptions of unidimensionality and local independence. Dimensionality was evaluated using factor analytic methods; local dependence (LD) was tested using IRT-based LD indices. Wald tests were used to examine group differences in IRT parameters, and to test DIF hypotheses. A second DIF-detection method used in sensitivity analyses was based on ordinal logistic regression with a latent IRT-derived conditioning variable. Magnitude and impact of DIF were investigated, and reliability and item and scale information statistics were estimated. The reliability of the short form item set was excellent. However, there were a few items with high local dependency, which affected the estimation of the final discrimination parameters. As a result, the item, "How much did pain interfere with enjoyment of social activities?" was excluded in the DIF analyses for all subgroup comparisons. No items were hypothesized to show DIF for race and ethnicity; however, five items showed DIF after adjustment for multiple comparisons in both primary and sensitivity analyses: ability to concentrate, enjoyment of recreational activities, tasks away from home, participation in social activities, and socializing with others. The magnitude of DIF was small and the impact negligible. Three items were consistently identified with DIF for education: enjoyment of life, ability to concentrate, and enjoyment of recreational activities. No item showed DIF above the magnitude threshold and the impact of DIF on the overall measure was minimal. No item showed gender DIF after correction for multiple comparisons in the primary analyses. Four items showed consistent age DIF: enjoyment of life, ability to concentrate, day to day activities, and enjoyment of recreational activities, none with primary magnitude values above threshold. Conditional on the pain state, Spanish speakers were hypothesized to report less pain interference on one item, enjoyment of life. The DIF findings confirmed the hypothesis; however, the magnitude was small. Using an arbitrary cutoff point of theta ( θ ) ≥ 1.0 to classify respondents with acute pain interference, the highest number of changes were for the education groups analyses. There were 231 respondents (4% of the total sample) who changed from the designation of no acute pain interference to acute interference after the DIF adjustment. There was no change in the designations for race/ethnic subgroups, and a small number of changes for respondents aged 65 to 84. Although significant DIF was observed after correction for multiple comparisons, all DIF was of low magnitude and impact. However, some individual-level impact was observed for low education groups. Reliability estimates were high. Thus, the PROMIS short form pain items examined in this ethnically diverse sample performed relatively well; although one item was problematic and removed from the analyses. It is concluded that the majority of the PROMIS pain interference short form items can be recommended for use among ethnically diverse groups, including those in palliative care and with cancer and chronic illness.

  14. Measurement Equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS®) Pain Interference Short Form Items: Application to Ethnically Diverse Cancer and Palliative Care Populations

    PubMed Central

    Teresi, Jeanne A.; Ocepek-Welikson, Katja; Cook, Karon F.; Kleinman, Marjorie; Ramirez, Mildred; Reid, M. Carrington; Siu, Albert

    2017-01-01

    Reducing the response burden of standardized pain measures is desirable, particularly for individuals who are frail or live with chronic illness, e.g., those suffering from cancer and those in palliative care. The Patient Reported Outcome Measurement Information System® (PROMIS®) project addressed this issue with the provision of computerized adaptive tests (CAT) and short form measures that can be used clinically and in research. Although there has been substantial evaluation of PROMIS item banks, little is known about the performance of PROMIS short forms, particularly in ethnically diverse groups. Reviewed in this article are findings related to the differential item functioning (DIF) and reliability of the PROMIS pain interference short forms across diverse sociodemographic groups. Methods DIF hypotheses were generated for the PROMIS short form pain interference items. Initial analyses tested item response theory (IRT) model assumptions of unidimensionality and local independence. Dimensionality was evaluated using factor analytic methods; local dependence (LD) was tested using IRT-based LD indices. Wald tests were used to examine group differences in IRT parameters, and to test DIF hypotheses. A second DIF-detection method used in sensitivity analyses was based on ordinal logistic regression with a latent IRT-derived conditioning variable. Magnitude and impact of DIF were investigated, and reliability and item and scale information statistics were estimated. Results The reliability of the short form item set was excellent. However, there were a few items with high local dependency, which affected the estimation of the final discrimination parameters. As a result, the item, “How much did pain interfere with enjoyment of social activities?” was excluded in the DIF analyses for all subgroup comparisons. No items were hypothesized to show DIF for race and ethnicity; however, five items showed DIF after adjustment for multiple comparisons in both primary and sensitivity analyses: ability to concentrate, enjoyment of recreational activities, tasks away from home, participation in social activities, and socializing with others. The magnitude of DIF was small and the impact negligible. Three items were consistently identified with DIF for education: enjoyment of life, ability to concentrate, and enjoyment of recreational activities. No item showed DIF above the magnitude threshold and the impact of DIF on the overall measure was minimal. No item showed gender DIF after correction for multiple comparisons in the primary analyses. Four items showed consistent age DIF: enjoyment of life, ability to concentrate, day to day activities, and enjoyment of recreational activities, none with primary magnitude values above threshold. Conditional on the pain state, Spanish speakers were hypothesized to report less pain interference on one item, enjoyment of life. The DIF findings confirmed the hypothesis; however, the magnitude was small. Using an arbitrary cutoff point of theta (θ) ≥ 1.0 to classify respondents with acute pain interference, the highest number of changes were for the education groups analyses. There were 231 respondents (4% of the total sample) who changed from the designation of no acute pain interference to acute interference after the DIF adjustment. There was no change in the designations for race/ethnic subgroups, and a small number of changes for respondents aged 65 to 84. Conclusions Although significant DIF was observed after correction for multiple comparisons, all DIF was of low magnitude and impact. However, some individual-level impact was observed for low education groups. Reliability estimates were high. Thus, the PROMIS short form pain items examined in this ethnically diverse sample performed relatively well; although one item was problematic and removed from the analyses. It is concluded that the majority of the PROMIS pain interference short form items can be recommended for use among ethnically diverse groups, including those in palliative care and with cancer and chronic illness. PMID:28983449

  15. Selected problems with boron determination in water treatment processes. Part I: comparison of the reference methods for ICP-MS and ICP-OES determinations.

    PubMed

    Kmiecik, Ewa; Tomaszewska, Barbara; Wątor, Katarzyna; Bodzek, Michał

    2016-06-01

    The aim of the study was to compare the two reference methods for the determination of boron in water samples and further assess the impact of the method of preparation of samples for analysis on the results obtained. Samples were collected during different desalination processes, ultrafiltration and the double reverse osmosis system, connected in series. From each point, samples were prepared in four different ways: the first was filtered (through a membrane filter of 0.45 μm) and acidified (using 1 mL ultrapure nitric acid for each 100 mL of samples) (FA), the second was unfiltered and not acidified (UFNA), the third was filtered but not acidified (FNA), and finally, the fourth was unfiltered but acidified (UFA). All samples were analysed using two analytical methods: inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The results obtained were compared and correlated, and the differences between them were studied. The results show that there are statistically significant differences between the concentrations obtained using the ICP-MS and ICP-OES techniques regardless of the methods of sampling preparation (sample filtration and preservation). Finally, both the ICP-MS and ICP-OES methods can be used for determination of the boron concentration in water. The differences in the boron concentrations obtained using these two methods can be caused by several high-level concentrations in selected whole-water digestates and some matrix effects. Higher concentrations of iron (from 1 to 20 mg/L) than chromium (0.02-1 mg/L) in the samples analysed can influence boron determination. When iron concentrations are high, we can observe the emission spectrum as a double joined and overlapping peak.

  16. Injuries affect team performance negatively in professional football: an 11-year follow-up of the UEFA Champions League injury study.

    PubMed

    Hägglund, Martin; Waldén, Markus; Magnusson, Henrik; Kristenson, Karolina; Bengtsson, Håkan; Ekstrand, Jan

    2013-08-01

    The influence of injuries on team performance in football has only been scarcely investigated. To study the association between injury rates and team performance in the domestic league play, and in European cups, in male professional football. 24 football teams from nine European countries were followed prospectively for 11 seasons (2001-2012), including 155 team-seasons. Individual training and match exposure and time-loss injuries were registered. To analyse the effect of injury rates on performance, a Generalised Estimating Equation was used to fit a linear regression on team-level data. Each team's season injury rate and performance were evaluated using its own preceding season data for comparison in the analyses. 7792 injuries were reported during 1 026 104 exposure hours. The total injury incidence was 7.7 injuries/1000 h, injury burden 130 injury days lost/1000 h and player match availability 86%. Lower injury burden (p=0.011) and higher match availability (p=0.031) were associated with higher final league ranking. Similarly, lower injury incidence (p=0.035), lower injury burden (p<0.001) and higher match availability (p<0.001) were associated with increased points per league match. Finally, lower injury burden (p=0.043) and higher match availability (p=0.048) were associated with an increase in the Union of European Football Association (UEFA) Season Club Coefficient, reflecting success in the UEFA Champions League or Europa League. Injuries had a significant influence on performance in the league play and in European cups in male professional football. The findings stress the importance of injury prevention to increase a team's chances of success.

  17. Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NMISA (South Africa) and the BIPM

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Khoza, Michael

    2017-01-01

    This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NMISA (South Africa) and the BIPM carried out in 2016. The comparison at 10 pF forms part of the ongoing BIPM key comparison BIPM.EM-K14.a and that at 100 pF of the ongoing BIPM key comparison BIPM.EM-K14.b. The BIPM is the pilot laboratory for both of these comparisons. Two 10 pF and 100 pF travelling standards belonging to the BIPM were used in this comparison carried out with an 'A-B-A' pattern of measurements. The standards were measured first at the BIPM for a period of about one month, then for a similar period at the NMISA, and finally again at the BIPM. The measurand was the two terminal-pair capacitance at a frequency of either 1000 Hz or 1592 Hz, for a measuring rms voltage of 15 V at 10 pF and 10 V at 100 pF. One of the 10 pF travelling standards had to be eliminated from the comparison due to a bistable behaviour, possibly due to transportation. The results from the NMISA and the BIPM at both 1000 Hz and 1592 Hz were found to be in good agreement, with a difference smaller than the relative expanded uncertainty (95 % confidence, k = 2) of maximum value 0.33 × 10-6 at 10 pF and 0.24 × 10-6 at 100 pF (and 1000 Hz in both cases). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on key comparison APMP.M.P-K3: Absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Yoshida, H.; Arai, K.; Akimichi, H.; Hong, S. S.; Song, H. W.

    2011-01-01

    The results of a key comparison of ultra-high vacuum standards at two national metrology institutes (NMIJ/AIST and KRISS) are reported. This bilateral comparison was carried out from May 2010 to October 2010 within the framework of the Asia-Pacific Metrology Programme (APMP) to determine their degrees of equivalence at pressures in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. The pilot institute was NMIJ/AIST. Two spinning rotor gauges and two hot cathode ionization gauges were used as the transfer standards. NMIJ/AIST used two calibration systems: the dynamic expansion system (NMIJ-DES) and two-stage flow-dividing system (NMIJ-TFS). KRISS used the dynamic expansion system. The transfer standards were sufficiently stable to meet the requirements of the comparison compared with those of previous international comparisons owing to some improvements of the protocol and the transfer standards. The ultra-high vacuum standards of NMIJ/AIST and KRISS were found to be equivalent within their claimed uncertainties in the range from 3 × 10-6 Pa to 9 × 10-5 Pa. The NMIJ-DES results, which have smaller uncertainty than NMIJ-TFS, were transferred to the corresponding CCM key comparison, CCM.P-K3, in the range from 3 × 10-6 Pa to 9 × 10-5 Pa and it is shown that the NMIJ values were equivalent to the CCM key comparison reference value within the claimed uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Final report on EURAMET.QM-S6/1195: Bilateral comparison of liquefied hydrocarbon mixtures in constant pressure (piston) cylinders

    NASA Astrophysics Data System (ADS)

    Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong

    2013-01-01

    Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Economic Analyses in Anterior Cruciate Ligament Reconstruction: A Qualitative and Systematic Review.

    PubMed

    Saltzman, Bryan M; Cvetanovich, Gregory L; Nwachukwu, Benedict U; Mall, Nathan A; Bush-Joseph, Charles A; Bach, Bernard R

    2016-05-01

    As the health care system in the United States (US) transitions toward value-based care, there is an increased emphasis on understanding the cost drivers and high-value procedures within orthopaedics. To date, there has been no systematic review of the economic literature on anterior cruciate ligament reconstruction (ACLR). To evaluate the overall evidence base for economic studies published on ACLR in the orthopaedic literature. Data available on the economics of ACLR are summarized and cost drivers associated with the procedure are identified. Systematic review. All economic studies (including US-based and non-US-based) published between inception of the MEDLINE database and October 3, 2014, were identified. Given the heterogeneity of the existing evidence base, a qualitative, descriptive approach was used to assess the collective results from the economic studies on ACLR. When applicable, comparisons were made for the following cost-related variables associated with the procedure for economic implications: outpatient versus inpatient surgery (or outpatient vs overnight hospital stay vs >1-night stay); bone-patellar tendon-bone (BPTB) graft versus hamstring (HS) graft source; autograft versus allograft source; staged unilateral ACLR versus bilateral ACLR in a single setting; single- versus double-bundle technique; ACLR versus nonoperative treatment; and other unique comparisons reported in single studies, including computer-assisted navigation surgery (CANS) versus traditional surgery, early versus delayed ACLR, single- versus double-incision technique, and finally the costs of ACLR without comparison of variables. A total of 24 studies were identified and included; of these, 17 included studies were cost identification studies. The remaining 7 studies were cost utility analyses that used economic models to investigate the effect of variables such as the cost of allograft tissue, fixation devices, and physical therapy, the percentage and timing of revision surgery, and the cost of revision surgery. Of the 24 studies, there were 3 studies with level 1 evidence, 8 with level 2 evidence, 6 with level 3 evidence, and 7 with level 4 evidence. The following economic comparisons were demonstrated: (1) ACLR is more cost-effective than nonoperative treatment with rehabilitation only (per 3 cost utility analyses); (2) autograft use had lower total costs than allograft use, with operating room supply costs and allograft costs most significant (per 5 cost identification studies and 1 cost utility analysis); (3) results on hamstring versus BPTB graft source are conflicting (per 2 cost identification studies); (4) there is significant cost reduction with an outpatient versus inpatient setting (per 5 studies using cost identification analyses); (5) bilateral ACLR is more cost efficient than 2 unilateral ACLRs in separate settings (per 2 cost identification studies); (6) there are lower costs with similarly successful outcomes between single- and double-bundle technique (per 3 cost identification studies and 2 cost utility analyses). Results from this review suggest that early single-bundle, single (endoscopic)-incision outpatient ACLR using either BPTB or HS autograft provides the most value. In the setting of bilateral ACL rupture, single-setting bilateral ACLR is more cost-effective than staged unilateral ACLR. Procedures using CANS technology do not yet yield results that are superior to the results of a standard surgical procedure, and CANS has substantially greater costs. © 2015 The Author(s).

  1. Examination of Demographic Differences Between the United States Population and the United States Air Force

    DTIC Science & Technology

    1999-04-01

    realm of gender and race /ethnic background. Finally, analysis is accomplished on these differences and conclusions drawn to ascertain any consequences... Race /Ethnic Comparison ............................................................................................ 31 Hispanic Population...Population............................................................................ 36 Race /Ethnic by Gender Comparison

  2. Final report on the regional supplementary comparison APMP.AUV.A-S1

    NASA Astrophysics Data System (ADS)

    Plangsangmas, Virat; Leeudomwong, Surat; Scott, Andrew; Zhong, Bo; Huang, Yuchung

    2014-01-01

    A regional supplementary comparison APMP.AUV.A-S1 has been carried out for the measurement of sound pressure level, frequency and total distortion of a multi-frequency sound calibrator. The role of the Pilot laboratory was undertaken by the National Institute of Metrology (Thailand) (NIMT). The multi-frequency sound calibrator was circulated through thirteen National Metrology Institutes (NMIs). Two NMIs were added to the original time schedule after starting the circulation. The measurements took place between September 2008 and July 2010. This report includes the measurement results from all the participants. Supplementary Comparison Reference Values (SCRVs) have been determined from the results. Deviations from the SCRVs are mostly within declared expanded uncertainties. It has been found that a term for the inherent instability in this type of device needs to be included in any uncertainty budget, and a recommended minimum value of this has been given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  3. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  4. 75 FR 14569 - Polyethylene Retail Carrier Bags from Taiwan: Final Determination of Sales at Less Than Fair Value

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... excludes (1) polyethylene bags that are not printed with logos or store names and that are closeable with... comparison methodology to TCI's targeted sales and the average-to-average comparison methodology to TCI's non... average-to-average comparison method does not account for such price differences and results in the...

  5. SIM key comparison for luminous flux. SIM.PR-K4

    NASA Astrophysics Data System (ADS)

    Matamoros, Carlos H.; Ohno, Yoshi; Zwinkels, Joanne; Cogno, Jorge A.; Couceiro, Iakyra B.

    2016-01-01

    In compliance with the established BIPM and CCPR policies and guidelines on comparisons, the SIM Photometry and Radiometry Working Group decided to conduct a key comparison on total luminous flux in order to provide an opportunity for its member National Metrology Institutes (NMIs) that did not participate in the CCPR-K4 comparison, to get a link to the reference value obtained for this quantity (the lumen) and to derive the corresponding degrees of equivalence. This SIM.PR-K4 was piloted by Centro Nacional de Metrología (CENAM), the NMI of Mexico and included the participation of five laboratories: CENAM (Mexico), INTI (Argentina), INMETRO (Brazil), NIST (USA, linking lab), and NRC (Canada, linking lab). The comparison, conducted in star type scheme, was run using three to four lamps per participant, and results are given in this report, including the unilateral degrees of equivalence. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. APMP supplementary comparison report of absorbed dose rate in tissue for beta radiation (BIPM KCDB: APMP.RI(I)-S2)

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurosawa, T.; Saito, N.; Kadni, T. B.; Kim, I. J.; Kim, B. C.; Yi, C.-Y.; Pungkun, V.; Chu, C.-H.

    2017-01-01

    The supplementary comparison of absorbed dose rate in tissue for beta radiation (APMP.RI(I)-S2) was performed with five national metrology institutes in 2013 and 2014. Two commercial thin window ionization chambers were used as transfer instruments and circulated among the participants. Two of the NMIs measured the calibration coefficients of the chambers in reference fields produced from Pm-147, Kr-85 and Sr-90/Y-90, while the other three measured those only in Sr-90/Y-90 beta-particle field. The degree of equivalence for the participants was determined and this comparison verifies the calibration capabilities of the participating laboratories. In addition, most of the results of this comparison are consistent with another international comparison (EUROMET.RI(I)-S2) reported before this work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. International comparison Euramet.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Wouter van der Hout, J.; van der Veen, Adriaan M. H.; Ziel, Paul R.; Kipphardt, Heinrich; Tuma, Dirk; Maiwald, Michael; Fernández, Teresa E.; Gómez, Concepción; Cieciora, Dariusz; Ochman, Grzegorz; Dias, Florbela; Silvino, Victor; Macé, Tatiana; Sutour, Christophe; Marioni, Fabrice; Ackermann, Andreas; Niederhauser, Bernhard; Fükő, Judit; Büki, Tamás; Nagyné Szilágyi, Zsófia; Tarhan, Tanıl; Engin, Erinç

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare Primary Standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as an RMO track A key comparison. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results are within +/- 1 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. APMP supplementary comparison (APMP.L-S8) measurement of flatness of optical flat by interferometry

    NASA Astrophysics Data System (ADS)

    Buajarern, J.; Bitou, Y.; Zi, X.; Zhao, L.; Swift, N.; Agarwal, A.; Hungwe, F.

    2018-01-01

    A reginal supplementary comparison, APMP.L-S8, was started in 2015 to demonstrate the equivalence of routine calibration services offered by NMIs to clients. Participants in this APMP.L-S8 comparison agreed to apply interferometric method for flatness measurement of the optical flats. There are two configurations of flatness interferometer used in this comparison, vertical type and horizontal type. There are seven laboratories from NMIs participated this supplementary comparison which included NIMT, NMIJ, NIM, NMC/A*STAR, MSL, NPLI and NMISA. This report describes the measurement results of two optical flats, diameter of 70 mm and 160 mm. The calibrations of this comparison were carried out by participants during the period from July 2015 to September 2016. The results show that there is a degree of equivalence below 1 for all measurands. Hence, there is a close agreement between the measurements from all participants. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database. The results can be used to link regional comparisons to this CCM key comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. APMP.QM-S8: determination of mass fraction of benzoic acid, methyl paraben and n-butyl paraben in soy sauce

    NASA Astrophysics Data System (ADS)

    Teo, Tang Lin; Gui, Ee Mei; Lu, Ting; Sze Cheow, Pui; Giannikopoulou, Panagiota; Kakoulides, Elias; Lampi, Evgenia; Choi, Sik-man; Yip, Yiu-chung; Chan, Pui-kwan; Hui, Sin-kam; Wollinger, Wagner; Carvalho, Lucas J.; Garrido, Bruno C.; Rego, Eliane C. P.; Ahn, Seonghee; Kim, Byungjoo; Li, Xiuqin; Guo, Zhen; Styarini, Dyah; Aristiawan, Yosi; Putri Ramadhaningtyas, Dillani; Aryana, Nurhani; Ebarvia, Benilda S.; Dacuaya, Aaron; Tongson, Alleni; Aganda, Kim Christopher; Junvee Fortune, Thippaya; Tangtrirat, Pradthana; Mungmeechai, Thanarak; Ceyhan Gören, Ahmet; Gündüz, Simay; Yilmaz, Hasibe

    2017-01-01

    The supplementary comparison APMP.QM-S8: determination of mass fraction of benzoic acid, methyl paraben and n-butyl paraben in soy sauce was coordinated by the Health Sciences Authority, Singapore under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM). Ten national metrology institutes (NMIs) or designated institutes (DIs) participated in the comparison. All the institutes participated in the comparison for benzoic acid, while six NMIs/DIs participated in the comparison for methyl paraben and n-butyl paraben. The comparison was designed to enable participating institutes to demonstrate their measurement capabilities in the determination of common preservatives in soy sauce, using procedure(s) that required simple sample preparation and selective detection in the mass fraction range of 50 to 1000 mg/kg. The demonstrated capabilities can be extended to include other polar food preservatives (e.g. sorbic acid, propionic acid and other alkyl benzoates) in water, aqueous-based beverages (e.g. fruit juices, tea extracts, sodas, sports drinks, etc) and aqueous-based condiments (e.g. vinegar, fish sauce, etc). Liquid--liquid extraction and/or dilution were applied, followed by instrumental analyses using LC-MS/MS, LC-MS, GC-MS (with or without derivatisation) or HPLC-DAD. Isotope dilution mass spectrometry was used for quantification, except in the case of a participating institute, where external calibration method was used for quantification of all three measurands. The assigned Supplementary Comparison Reference Values (SCRVs) were the medians of ten results for benzoic acid, six results for methyl paraben and six results for n-butyl paraben. Benzoic acid was assigned a SCRV of 154.55 mg/kg with a combined standard uncertainty of 0.94 mg/kg, methyl paraben was assigned a SCRV of 100.95 mg/kg with a combined standard uncertainty of 0.40 mg/kg, and n-butyl paraben was assigned a SCRV of 99.05 mg/kg with a combined standard uncertainty of 1.36 mg/kg. The k-factors for the estimation of the expanded uncertainties of the SCRVs were 2.26, 2.57 and 2.57, respectively. The degree of equivalence (with the SCRV) and its uncertainty were calculated for each result. All the participating institutes (except in one case for benzoic acid) were able to demonstrate or confirm their capabilities in the determination of polar food preservatives in water or aqueous-based beverages/condiments. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Student distress in clinical workplace learning: differences in social comparison behaviours.

    PubMed

    Janet Raat, A N; Schönrock-Adema, Johanna; van Hell, E Ally; Kuks, Jan B M; Cohen-Schotanus, Janke

    2015-03-01

    In medical education, student distress is known to hamper learning and professional development. To address this problem, recent studies aimed at helping students cope with stressful situations. Undergraduate students in clinical practice frequently use experiences of surrounding peers to estimate their abilities to master such challenging situations. This use of the experiences of others, known as social comparison, may affect student distress both positively and negatively. To find characteristics of a beneficial use of social comparison, we examined differences in comparison behaviours between students expressing low and high levels of distress. The participants in our study, response rate 93% (N = 301/321), were all medical students in their first year in clinical practice. They completed the General Health Questionnaire (GHQ-12) to measure distress, and three separate questionnaires to measure: (1) orientation to comparison, (2) motive for comparison, and (3) interpretation of comparison. Differences were analysed using multivariate analysis of variance. Although all students were oriented towards social comparison, the analyses showed that this orientation was less apparent among low-distress students. Besides, the low-distress students were less inclined to use motives indicative for comparisons with peers perceived as performing worse and were less negative in the interpretations of their comparisons. As social comparison is frequently used among all students, we recommend to make them aware of their comparison behaviours and inform them about the pros and cons of the distinguished aspects of the comparison process.

  12. Behind the Final Grade in Hybrid v. Traditional Courses: Comparing Student Performance by Assessment Type, Core Competency, and Course Objective

    ERIC Educational Resources Information Center

    Bain, Lisa Z.

    2012-01-01

    There are many different delivery methods used by institutions of higher education. These include traditional, hybrid, and online course offerings. The comparisons of these typically use final grade as the measure of student performance. This research study looks behind the final grade and compares student performance by assessment type, core…

  13. COOMET.QM-K93 (COOMET 615/RU/13): key comparison in the field of measuring of the ethanol amount fraction in nitrogen (120 μmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Efremova, O. V.; Fatina, O. V.; Orshanskaia, A. A.; Rozhnov, M. S.; Melnyk, D. M.; Petryshyn, P. V.

    2016-01-01

    The relevance of the COOMET.QM-K93 comparison is founded on paying particular attention to reliability of measurements which are performed during the medical examination of drivers of vehicles in order to assess the degree of alcoholic intoxication. Standard gas mixtures of ethanol in nitrogen in cylinders under pressure play a key role in providing metrological assurance of breath-alcohol analyzers. Participating laboratories: VNIIM and Ukrmetrteststandart. This comparison was carried out in 2014-2015. This supplementary comparison supports CMC claims for: ethanol in the range 50-500 μmol/mol in a matrix of either nitrogen or synthetic air. Results: The results are consistent with the reference values. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    NASA Astrophysics Data System (ADS)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Bilateral key comparison CCM.P-K3.1 for absolute pressure measurements from 3 × 10-6 Pa to 9 × 10-4 Pa

    NASA Astrophysics Data System (ADS)

    Fedchak, J. A.; Bock, Th; Jousten, K.

    2014-01-01

    This report describes the bilateral key comparison CCM.P-K3.1 between the National Institute of Standards and Technology (NIST) and Physikalisch-Technische Bundesanstalt (PTB) for absolute pressure in the range from 3 × 10-6 Pa to 9 × 10-4 Pa. This comparison was a follow-up to the comparison CCM.P-K3. Two ionization gauges and two spinning rotor gauges (SRGs) were used as the transfer standards for the comparison. The SRGs were used to compare the standards at a pressure of 9 × 10-4 Pa and to normalize the ionization gauge readings. The two ionization gauges were used to compare the standards in the pressure range of from 3 × 10-6 Pa to 3 × 10-4 Pa. Both laboratories used dynamic expansion chambers as standards in the comparison. The two labs showed excellent agreement with each other and with the CCM.P-K3 key comparison reference value (KCRV) over the entire range. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. On a comparison of Huber-Mises-Hencky with Burzynski-Pecherski equivalent stresses for glass body during nonstationary thermal load

    NASA Astrophysics Data System (ADS)

    Badur, Janusz; Bryk, Mateusz; Ziolkowski, Pawel; Slawinski, Daniel; Ziolkowski, Piotr; Kornet, Sebastian; Stajnke, Michal

    2017-03-01

    Glass materials are constantly the base of life the majority of society. A lot of us, every morning brew a cup of tea or coffee in his favourite cup or look out glass pane in order to define the weather outside. Examples can be multiplied and multiplied. On account the role of glass materials, in most people life, has been decided to choice a glass material as a base to perform thermal FSI analysis. However the analysis would be nothing without calculative model. It is well known that there are various strength hypothesis, which treat of material strength dependency on reduced tension. In most cases, to the issue which is related to reduced tensions appointment which appear in analysed material, the Huber-Mises-Hencky hypothesis is used, but it is difficult to model glass material by this hypothesis. It happens because of specific properties of glass, which is amorphous body. And here, with help occurs the W.Burzynski, Huber's student. Burzynski proposed the following reduced tension definition: Φf+η (p )ṡΦv=K , from which the Burzynski material effort is calculated:σB=1/2 k ṡ[ -(k -1 )ṡσm+√{(k-1 ) 2ṡσm2+4 ṡk ṡσHM H 2 } ] . We reached to the idea, which is the introduction of material properties coefficient k. This parameter describes the relation of compressing strength to the tensile strength. Furthermore, R. Pecherski proposed the Burzynski hypothesis enlargement by Lode's angle influence, which controls the participation of the energy density of distortion. Finally the Burzynski-Pecherski hypothesis is: η˜f(θ )ϕf+η˜v(p )ϕv=K . Where θ describes Lode's angle. In this work is presented the comparison of aforementioned hypothesis and delimitation the differences in received results stresses values by each one of hypothesis. As example of analysed problem the cold glass cup under nonstationary thermal load (which is simulated by boiled water) is taken under consideration. The analysis consist of flow calculations, bounded with filling the glass cup by hot fluid, import of geometry inner walls temperature values and finally calculation of reduced stresses using both strength hypothesis.

  18. Calibration of mass and conventional mass of weights 2 kg, 1 kg, 200 g, 50 g, 1 g and 200 mg

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Peña, Luis Manuel; Escalante Vargas, Boris; Cori Almonte, Luz; Martín Quiroga Rojas, Aldo; Bermúdez Coronel, Álvaro; Escobar Soto, Jhon J.; Naula, Wilson; Florencio, Arnaldo; Lourdes Valenzuela, María; Ramos Alfaro, Olman; Prenda Peña, Marcela

    2018-01-01

    This report describes the results of a supplementary comparison between SIM NMIs, which was carried out to evaluate the consistency of the measurements of calibration in high accuracy mass standards using the normalized error criteria (2 kg, 1 kg, 200 g, 50 g, 1 g and 200 mg). The supplementary comparison was carried out from April 2012 to July 2013. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Force supplementary comparison at SIM (SIM.M.F-S5), compression testing machines calibration, up to 200 kN

    NASA Astrophysics Data System (ADS)

    Cárdenas Moctezuma, A.; Torres Guzmán, J. C.

    2016-01-01

    CENAM, through the Force and Pressure Division, organized a comparison on testing machines calibration, in compression mode. The participating laboratories were SIM National Institutes of Metrology from Colombia, Peru and Costa Rica, where CENAM, Mexico was the pilot and reference laboratory. The results obtained by the laboratories are presented in this paper as well as the analysis of compatibility. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison on the calibration of a set of F1 mass standards between IBMETRO (Bolivia) and INTI (Argentina)

    NASA Astrophysics Data System (ADS)

    Quille, Ruben; Sanchez, Jorge; Escalante, Boris

    2017-01-01

    Mass calibration is an important activity for National Metrology Institutes (NMIs), due to the amount of measurements on scientific, industrial and legal activities that have traceability to the national mass standards of each country. In order to evaluate the stated uncertainty and degree of equivalence between INTI-Argentina and IBMETRO-Bolivia on mass calibration a bilateral comparison was agreed between both laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Methodological Quality of Meta-Analyses: Matched-Pairs Comparison over Time and between Industry-Sponsored and Academic-Sponsored Reports

    ERIC Educational Resources Information Center

    Lane, Peter W.; Higgins, Julian P. T.; Anagnostelis, Betsy; Anzures-Cabrera, Judith; Baker, Nigel F.; Cappelleri, Joseph C.; Haughie, Scott; Hollis, Sally; Lewis, Steff C.; Moneuse, Patrick; Whitehead, Anne

    2013-01-01

    Context: Meta-analyses are regularly used to inform healthcare decisions. Concerns have been expressed about the quality of meta-analyses and, in particular, about those supported by the pharmaceutical industry. Objective: The objective of this study is to compare the quality of pharmaceutical-industry-supported meta-analyses with academic…

  2. Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications

    DOT National Transportation Integrated Search

    1998-12-01

    Original Report date: October 1997. This is the first and final report for research project 0-1721, "Effectiveness Comparison of TxDOT Quality Control/Quality Assurance and Method Specifications." This study was established and sponsored by TxDOT to ...

  3. A Method for Quantifying, Visualising, and Analysing Gastropod Shell Form

    PubMed Central

    Liew, Thor-Seng; Schilthuizen, Menno

    2016-01-01

    Quantitative analysis of organismal form is an important component for almost every branch of biology. Although generally considered an easily-measurable structure, the quantification of gastropod shell form is still a challenge because many shells lack homologous structures and have a spiral form that is difficult to capture with linear measurements. In view of this, we adopt the idea of theoretical modelling of shell form, in which the shell form is the product of aperture ontogeny profiles in terms of aperture growth trajectory that is quantified as curvature and torsion, and of aperture form that is represented by size and shape. We develop a workflow for the analysis of shell forms based on the aperture ontogeny profile, starting from the procedure of data preparation (retopologising the shell model), via data acquisition (calculation of aperture growth trajectory, aperture form and ontogeny axis), and data presentation (qualitative comparison between shell forms) and ending with data analysis (quantitative comparison between shell forms). We evaluate our methods on representative shells of the genera Opisthostoma and Plectostoma, which exhibit great variability in shell form. The outcome suggests that our method is a robust, reproducible, and versatile approach for the analysis of shell form. Finally, we propose several potential applications of our methods in functional morphology, theoretical modelling, taxonomy, and evolutionary biology. PMID:27280463

  4. Response of the Alliance 1 Proof-of-Concept Airplane Under Gust Loads

    NASA Technical Reports Server (NTRS)

    Naser, A. S.; Pototzky, A. S.; Spain, C. V.

    2001-01-01

    This report presents the work performed by Lockheed Martin's Langley Program Office in support of NASA's Environmental Research Aircraft and Sensor Technology (ERAST) program. The primary purpose of this work was to develop and demonstrate a gust analysis method which accounts for the span-wise variation of gust velocity. This is important because these unmanned aircraft having high aspect ratios and low wing loading are very flexible, and fly at low speeds. The main focus of the work was therefore to perform a two-dimensional Power Spectrum Density (PSD) analysis of the Alliance 1 Proof-of-Concept Unmanned Aircraft, As of this writing, none of the aircraft described in this report have been constructed. They are concepts represented by analytical models. The process first involved the development of suitable structural and aeroelastic Finite Element Models (FEM). This was followed by development of a one-dimensional PSD gust analysis, and then the two-dimensional (PSD) analysis of the Alliance 1. For further validation and comparison, two additional analyses were performed. A two-dimensional PSD gust analysis was performed on a simplet MSC/NASTRAN example problem. Finally a one-dimensional discrete gust analysis was performed on Alliance 1. This report describes this process, shows the relevant comparisons between analytical methods, and discusses the physical meanings of the results.

  5. HIV Type 1 Transmission Networks Among Men Having Sex with Men and Heterosexuals in Kenya

    PubMed Central

    Faria, Nuno Rodrigues; Hassan, Amin; Hamers, Raph L.; Mutua, Gaudensia; Anzala, Omu; Mandaliya, Kishor; Cane, Patricia; Berkley, James A.; Rinke de Wit, Tobias F.; Wallis, Carole; Graham, Susan M.; Price, Matthew A.; Coutinho, Roel A.; Sanders, Eduard J.

    2014-01-01

    Abstract We performed a molecular phylogenetic study on HIV-1 polymerase sequences of men who have sex with men (MSM) and heterosexual patient samples in Kenya to characterize any observed HIV-1 transmission networks. HIV-1 polymerase sequences were obtained from samples in Nairobi and coastal Kenya from 84 MSM, 226 other men, and 364 women from 2005 to 2010. Using Bayesian phylogenetics, we tested whether sequences clustered by sexual orientation and geographic location. In addition, we used trait diffusion analyses to identify significant epidemiological links and to quantify the number of transmissions between risk groups. Finally, we compared 84 MSM sequences with all HIV-1 sequences available online at GenBank. Significant clustering of sequences from MSM at both coastal Kenya and Nairobi was found, with evidence of HIV-1 transmission between both locations. Although a transmission pair between a coastal MSM and woman was confirmed, no significant HIV-1 transmission was evident between MSM and the comparison population for the predominant subtype A (60%). However, a weak but significant link was evident when studying all subtypes together. GenBank comparison did not reveal other important transmission links. Our data suggest infrequent intermingling of MSM and heterosexual HIV-1 epidemics in Kenya. PMID:23947948

  6. Time-frequency featured co-movement between the stock and prices of crude oil and gold

    NASA Astrophysics Data System (ADS)

    Huang, Shupei; An, Haizhong; Gao, Xiangyun; Huang, Xuan

    2016-02-01

    The nonlinear relationships among variables caused by the hidden frequency information complicate the time series analysis. To shed more light on this nonlinear issue, we examine their relationships in joint time-frequency domain with multivariate framework, and the analyses in the time domain and frequency domain serve as comparisons. The daily Brent oil prices, London gold fixing price and Shanghai Composite index from January 1991 to September 2014 are adopted as example. First, they have long-term cointegration relationship in time domain from holistic perspective. Second, the Granger causality tests in different frequency bands are heterogeneous. Finally, the comparison between results from wavelet coherence and multiple wavelet coherence in the joint time-frequency domain indicates that in the high (1-14 days) and medium frequency (14-128 days) bands, the combination of Brent and gold prices has stronger correlation with the stock. In the low frequency band (256-512 days), year 2003 is the structure broken point before which Brent and oil are ideal choice for hedging the risk of the stock market. Thus, this paper offers more details between the Chinese stock market and the commodities markets of crude oil and gold, which suggests that the decisions for different time and frequencies should consider the corresponding benchmark information.

  7. Comparing Medical and Recreational Cannabis Users on Socio-Demographic, Substance and Medication Use, and Health and Disability Characteristics.

    PubMed

    Goulet-Stock, Sybil; Rueda, Sergio; Vafaei, Afshin; Ialomiteanu, Anca; Manthey, Jakob; Rehm, Jürgen; Fischer, Benedikt

    2017-01-01

    While recreational cannabis use is common, medical cannabis programs have proliferated across North America, including a federal program in Canada. Few comparisons of medical and recreational cannabis users (RCUs) exist; this study compared these groups on key characteristics. Data came from a community-recruited sample of formally approved medical cannabis users (MCUs; n = 53), and a sub-sample of recreational cannabis users (RCUs; n = 169) from a representative adult survey in Ontario (Canada). Samples were telephone-surveyed on identical measures, including select socio-demographic, substance and medication use, and health and disability measures. Based on initial bivariate comparisons, multivariate logistical regression with a progressive adjustment approach was performed to assess independent predictors of group status. In bivariate analyses, older age, lower household income, lower alcohol use, higher cocaine, prescription opioid, depression and anxiety medication use, and lower health and disability status were significantly associated with medical cannabis use. In the multivariate analysis, final model, household income, alcohol use, and disability levels were associated with medical cannabis use. Conclusions/Scientific Significance: Compared to RCUs, medical users appear to be mainly characterized by factors negatively influencing their overall health status. Future studies should investigate the actual impact and net benefits of medical cannabis use on these health problems. © 2017 S. Karger AG, Basel.

  8. Surface Roughness Optimization Using Taguchi Method of High Speed End Milling For Hardened Steel D2

    NASA Astrophysics Data System (ADS)

    Hazza Faizi Al-Hazza, Muataz; Ibrahim, Nur Asmawiyah bt; Adesta, Erry T. Y.; Khan, Ahsan Ali; Abdullah Sidek, Atiah Bt.

    2017-03-01

    The main challenge for any manufacturer is to achieve higher quality of their final products with maintains minimum machining time. In this research final surface roughness analysed and optimized with maximum 0.3 mm flank wear length. The experiment was investigated the effect of cutting speed, feed rate and depth of cut on the final surface roughness using D2 as a work piece hardened to 52-56 HRC, and coated carbide as cutting tool with higher cutting speed 120-240 mm/min. The experiment has been conducted using L9 design of Taguchi collection. The results have been analysed using JMP software.

  9. Testing of a simplified LED based vis/NIR system for rapid ripeness evaluation of white grape (Vitis vinifera L.) for Franciacorta wine.

    PubMed

    Giovenzana, Valentina; Civelli, Raffaele; Beghi, Roberto; Oberti, Roberto; Guidetti, Riccardo

    2015-11-01

    The aim of this work was to test a simplified optical prototype for a rapid estimation of the ripening parameters of white grape for Franciacorta wine directly in field. Spectral acquisition based on reflectance at four wavelengths (630, 690, 750 and 850 nm) was proposed. The integration of a simple processing algorithm in the microcontroller software would allow to visualize real time values of spectral reflectance. Non-destructive analyses were carried out on 95 grape bunches for a total of 475 berries. Samplings were performed weekly during the last ripening stages. Optical measurements were carried out both using the simplified system and a portable commercial vis/NIR spectrophotometer, as reference instrument for performance comparison. Chemometric analyses were performed in order to extract the maximum useful information from optical data. Principal component analysis (PCA) was performed for a preliminary evaluation of the data. Correlations between the optical data matrix and ripening parameters (total soluble solids content, SSC; titratable acidity, TA) were carried out using partial least square (PLS) regression for spectra and using multiple linear regression (MLR) for data from the simplified device. Classification analysis were also performed with the aim of discriminate ripe and unripe samples. PCA, MLR and classification analyses show the effectiveness of the simplified system in separating samples among different sampling dates and in discriminating ripe from unripe samples. Finally, simple equations for SSC and TA prediction were calculated. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Assessing the significance of pedobarographic signals using random field theory.

    PubMed

    Pataky, Todd C

    2008-08-07

    Traditional pedobarographic statistical analyses are conducted over discrete regions. Recent studies have demonstrated that regionalization can corrupt pedobarographic field data through conflation when arbitrary dividing lines inappropriately delineate smooth field processes. An alternative is to register images such that homologous structures optimally overlap and then conduct statistical tests at each pixel to generate statistical parametric maps (SPMs). The significance of SPM processes may be assessed within the framework of random field theory (RFT). RFT is ideally suited to pedobarographic image analysis because its fundamental data unit is a lattice sampling of a smooth and continuous spatial field. To correct for the vast number of multiple comparisons inherent in such data, recent pedobarographic studies have employed a Bonferroni correction to retain a constant family-wise error rate. This approach unfortunately neglects the spatial correlation of neighbouring pixels, so provides an overly conservative (albeit valid) statistical threshold. RFT generally relaxes the threshold depending on field smoothness and on the geometry of the search area, but it also provides a framework for assigning p values to suprathreshold clusters based on their spatial extent. The current paper provides an overview of basic RFT concepts and uses simulated and experimental data to validate both RFT-relevant field smoothness estimations and RFT predictions regarding the topological characteristics of random pedobarographic fields. Finally, previously published experimental data are re-analysed using RFT inference procedures to demonstrate how RFT yields easily understandable statistical results that may be incorporated into routine clinical and laboratory analyses.

  11. International comparison CCQM-K111.1—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capability of preparing Primary Standard gas Mixtures (PSMs), performing the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this subsequent key comparison is classified as a track B key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities for propane under the default scheme. The artefact was a binary mixture of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The result of the participating laboratory is consistent with the key comparison reference value within the respective expanded uncertainties and deviates less than 0.1 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Allisy-Roberts, P. J.; Burns, D. T.; Guerra, A. S.; Laitano, R. F.; Pimpinella, M.

    2010-01-01

    A comparison of the standards for absorbed dose to water of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI), and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the ENEA and the BIPM standards for absorbed dose to water, is 0.9999 (0.0044). The present 2007 result replaces the earlier ENEA value in this key comparison. The degrees of equivalence between the ENEA and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have published results in this ongoing comparison for absorbed dose to water. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  13. Final report on supplementary comparison APMP.M.P-S7.TRI in hydraulic gauge pressure from 40 MPa to 200 MPa

    NASA Astrophysics Data System (ADS)

    Kobata, Tokihiko; Olson, Douglas A.; Eltawil, Alaaeldin A.

    2017-01-01

    This report describes the results of a supplementary comparison of hydraulic high-pressure standards at three national metrology institutes (NMIs); National Metrology Institute of Japan, AIST (NMIJ/AIST), National Institute of Standards and Technology (NIST), USA and National Institute for Standards (NIS), Egypt, which was carried out at NIST during the period May 2001 to September 2001 within the framework of the Asia-Pacific Metrology Programme (APMP) in order to evaluate their degrees of equivalence at pressures in the range 40 MPa to 200 MPa for gauge mode. The pilot institute was NMIJ/AIST. Three working pressure standards from the institutes, in the form of piston-cylinder assemblies, were used for the comparison. The comparison and calculation methods used are discussed in this report. From the cross-float measurements, the differences between the working pressure standards of each institute were examined through an evaluation of the effective area of each piston-cylinder assembly with its uncertainty. From the comparison results, it was revealed that the values claimed by the participating institutes, NMIJ, NIST, and NIS, agree within the expanded (k = 2) uncertainties. The hydraulic pressure standards in the range 40 MPa to 200 MPa for gauge mode of the three participating NMIs were found to be equivalent within their claimed uncertainties. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. SUPPLEMENTARY COMPARISON: Final report of the bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B between PTB and NIMT

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo

    2009-01-01

    The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  15. High-resolution Monte Carlo simulation of flow and conservative transport in heterogeneous porous media: 1. Methodology and flow results

    USGS Publications Warehouse

    Naff, R.L.; Haley, D.F.; Sudicky, E.A.

    1998-01-01

    In this, the first of two papers concerned with the use of numerical simulation to examine flow and transport parameters in heterogeneous porous media via Monte Carlo methods, various aspects of the modelling effort are examined. In particular, the need to save on core memory causes one to use only specific realizations that have certain initial characteristics; in effect, these transport simulations are conditioned by these characteristics. Also, the need to independently estimate length scales for the generated fields is discussed. The statistical uniformity of the flow field is investigated by plotting the variance of the seepage velocity for vector components in the x, y, and z directions. Finally, specific features of the velocity field itself are illuminated in this first paper. In particular, these data give one the opportunity to investigate the effective hydraulic conductivity in a flow field which is approximately statistically uniform; comparisons are made with first- and second-order perturbation analyses. The mean cloud velocity is examined to ascertain whether it is identical to the mean seepage velocity of the model. Finally, the variance in the cloud centroid velocity is examined for the effect of source size and differing strengths of local transverse dispersion.

  16. Developing Army Leaders through Increased Rigor in Professional Military Training and Education

    DTIC Science & Technology

    2017-06-09

    leadership. Research Methodology An applied, exploratory, qualitative research methodology via a structured and focused case study comparison was...research methodology via a structured and focused case study comparison. Finally, it will discuss how the methodology will be conducted to make...development models; it serves as the base data for case study comparison. 48 Research Methodology and Data Analysis A qualitative research

  17. Bilateral comparison of 1 V and 10 V standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Simionescu, M.; Cîrneanu, L.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Institut National de Metrologie (INM), Bucharest, Romania, was carried out from August to October 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_8 (Z8), were transported by freight to INM. At INM, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at INM, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by INM, at the level of 1.018 V and 10 V, at INM, UINM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 6 September 2013. UINM - UBIPM = -0.014 µV uc = 0.051 µV, at 1 V UINM - UBIPM = -0.43 µV uc = 0.34 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at INM, based on KJ-90, and the uncertainty related to the comparison. These are satisfactory results. The comparison results show that the voltage standards maintained by INM and the BIPM were equivalent, within the comparison uncertainty, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final report on the key comparison CCPR-K5: Spectral diffuse reflectance

    NASA Astrophysics Data System (ADS)

    Nadal, Maria; Eckerle, Kenneth L.; Early, Edward A.; Ohno, Yoshi

    2013-01-01

    The CCPR K5 key comparison on spectral diffuse reflectance was carried out in the framework of the CIPM Mutual Recognition Arrangement, by 13 national metrology institutes (MMIs) as participants. The participants were CSIR-NML (South Africa), HUT (Finland), IFA-CSIC (Spain), KRISS (Republic of Korea), MSL (New Zealand), NIM (China), NIST (United States of America), NMIJ (Japan), NPL (United Kingdom), NRC (Canada), OMH (Hungary), PTB (Germany) and VNIIOFI (Russia Federation). NIST (USA) piloted the comparison. The aim of this comparison was to check the agreement of measurement of the spectral diffuse reflectance among participants, using the measurement geometry of d/0 or 0/d in the wavelength range of 360 nm to 820 nm at 20 nm increment. The comparison was a star type comparison with the samples provided by the pilot laboratory and with the measurement sequence: Pilot-Participant-Pilot. Spectralon and matte white ceramic tiles were used as the transfer standards. Each participant received three of each type of sample and at least one sample of each type was measured three times on three separate days, and the other two samples were measured once. The report presents the description of the measurement facilities, procedures and uncertainties of all the participants as well as the results of the comparison. Measurement results from the participants and their associated uncertainties were analyzed in accordance with the Guidelines for CCPR Key Comparison Report Preparation, using weighted mean with cut-off. For the calculation of the Key Comparison Reference Value (KCRV), as agreed by the participants, the data of both samples were used for the 460 nm to 820 nm region and only the data of the Spectralon samples were used in the spectral region of 360 nm to 440 nm. The unilateral degrees of equivalence (DoE) calculated for each participant are mostly consistent within the uncertainty (k = 2) of the DoE. This international comparison of spectral diffuse reflectance shows overall good agreement among all participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Pairwise-Comparison Software

    NASA Technical Reports Server (NTRS)

    Ricks, Wendell R.

    1995-01-01

    Pairwise comparison (PWC) is computer program that collects data for psychometric scaling techniques now used in cognitive research. It applies technique of pairwise comparisons, which is one of many techniques commonly used to acquire the data necessary for analyses. PWC administers task, collects data from test subject, and formats data for analysis. Written in Turbo Pascal v6.0.

  20. Planned Comparisons as Better Alternatives to ANOVA Omnibus Tests.

    ERIC Educational Resources Information Center

    Benton, Roberta L.

    Analyses of data are presented to illustrate the advantages of using a priori or planned comparisons rather than omnibus analysis of variance (ANOVA) tests followed by post hoc or posteriori testing. The two types of planned comparisons considered are planned orthogonal non-trend coding contrasts and orthogonal polynomial or trend contrast coding.…

  1. Pilot Study EURAMET.AUV.V-P1: Bilateral comparison on magnitude of the complex charge sensitivity of accelerometers from 10 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Bartoli, Claire; Hermawanto, Denny

    2017-01-01

    The results of a Pilot Study EURAMET.AUV.V-P1 between LNE (France) and RCM-LIPI (Indonesia) are reported. This bilateral comparison of sinusoidal vibration was organized after the implementation of various improvements at RCM-LIPI following a previous (unpublished) comparison that had revealed discrepancies in their results at frequencies above 5 kHz. The results of this Pilot Study, using the same accelerometers as the earlier comparison, demonstrate that the discrepancies at high frequencies have been resolved. For both the back-to-back and the single-ended accelerometers tested, the sensitivities of the RCM-LIPI and the LNE over the frequency range from 10 Hz to 10 kHz now agree within their declared uncertainties. Main text To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV.

  2. Activity measurements of the radionuclide 124Sb by the LNE-LNHB, France for the ongoing comparison BIPM.RI(II)-K1.Sb-124

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Moune, M.; Bobin, C.

    2011-01-01

    In 2007, the Laboratoire national de métrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of 124Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section II, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. KEY COMPARISON: CCEM.RF-K18.CL (GT-RF/00-1): Noise in 50 Ω coaxial line at frequencies up to 1 GHz

    NASA Astrophysics Data System (ADS)

    Eiø, Christopher; Adamson, David; Randa, James; Allal, Djamel; Uzdin, Rinadij

    2006-01-01

    A measurement comparison of noise temperature has been carried out between four national metrology laboratories in coaxial line at 30 MHz, 60 MHz and 1 GHz. The identification of this intercomparison is CCEM.RF-K18.CL. Two noise sources have been measured. The following four national laboratories participated in this intercomparison: NPL (United Kingdom), NIST (United States of America), BNM-LNE (France) and VNIIFTRI (Russia). The National Physical Laboratory (UK) acted as the pilot laboratory for the comparison. It can be seen that there is generally good agreement between the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. The role biomedical science laboratories can play in improving science knowledge and promoting first-year nursing academic success

    NASA Astrophysics Data System (ADS)

    Arneson, Pam

    The Role Biomedical Science Laboratories Can Play In Improving Science Knowledge and Promoting First-Year Nursing Academic Success The need for additional nursing and health care professionals is expected to increase dramatically over the next 20 years. With this in mind, students must have strong biomedical science knowledge to be competent in their field. Some studies have shown that participation in bioscience laboratories can enhance science knowledge. If this is true, an analysis of the role bioscience labs have in first-year nursing academic success is apposite. In response, this study sought to determine whether concurrent enrollment in anatomy and microbiology lecture and lab courses improved final lecture course grades. The investigation was expanded to include a comparison of first-year nursing GPA and prerequisite bioscience concurrent lecture/lab enrollment. Additionally, research has indicated that learning is affected by student perception of the course, instructor, content, and environment. To gain an insight regarding students' perspectives of laboratory courses, almost 100 students completed a 20-statement perception survey to understand how lab participation affects learning. Data analyses involved comparing anatomy and microbiology final lecture course grades between students who concurrently enrolled in the lecture and lab courses and students who completed the lecture course alone. Independent t test analyses revealed that there was no significant difference between the groups for anatomy, t(285) = .11, p = .912, but for microbiology, the lab course provided a significant educational benefit, t(256) = 4.47, p = .000. However, when concurrent prerequisite bioscience lecture/lab enrollment was compared to non-concurrent enrollment for first-year nursing GPA using independent t test analyses, no significant difference was found for South Dakota State University, t(37) = -1.57, p = .125, or for the University of South Dakota, t(38) = -0.46, p = .651. Student perception survey examination included computation of means and standard deviations for statements related to the educational importance of lab courses, the value of lab experimentation, and the usefulness of concurrent lecture/lab enrollment. Independent t test analyses sought to determine differences within the courses of anatomy lab and microbiology lab as well as differences between the instructors involved. Results suggested that student perceptions may be dependent on the course, the instructor, and possibly the content.

  5. Comparison of Written and Oral Examinations in a Baccalaureate Medical-Surgical Nursing Course.

    ERIC Educational Resources Information Center

    Rushton, Patricia; Eggett, Dennis

    2003-01-01

    Of four groups of medical-surgical nurses, 55 took one final and three midterm written exams, 150 took one each (written), 45 took an oral final, 92 took both written and oral, and 47 took a written test with licensure questions and an oral final. Oral exams resulted in higher scores, more effective study habits, and increased application. (SK)

  6. The development and validation of the Physical Appearance Comparison Scale-Revised (PACS-R).

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2014-04-01

    The Physical Appearance Comparison Scale (PACS; Thompson, Heinberg, & Tantleff, 1991) was revised to assess appearance comparisons relevant to women and men in a wide variety of contexts. The revised scale (Physical Appearance Comparison Scale-Revised, PACS-R) was administered to 1176 college females. In Study 1, exploratory factor analysis and parallel analysis using one half of the sample suggested a single factor structure for the PACS-R. Study 2 utilized the remaining half of the sample to conduct confirmatory factor analysis, item analysis, and to examine the convergent validity of the scale. These analyses resulted in an 11-item measure that demonstrated excellent internal consistency and convergent validity with measures of body satisfaction, eating pathology, sociocultural influences on appearance, and self-esteem. Regression analyses demonstrated the utility of the PACS-R in predicting body satisfaction and eating pathology. Overall, results indicate that the PACS-R is a reliable and valid tool for assessing appearance comparison tendencies in women. Copyright © 2014. Published by Elsevier Ltd.

  7. Predictive distributions were developed for the extent of heterogeneity in meta-analyses of continuous outcome data.

    PubMed

    Rhodes, Kirsty M; Turner, Rebecca M; Higgins, Julian P T

    2015-01-01

    Estimation of between-study heterogeneity is problematic in small meta-analyses. Bayesian meta-analysis is beneficial because it allows incorporation of external evidence on heterogeneity. To facilitate this, we provide empirical evidence on the likely heterogeneity between studies in meta-analyses relating to specific research settings. Our analyses included 6,492 continuous-outcome meta-analyses within the Cochrane Database of Systematic Reviews. We investigated the influence of meta-analysis settings on heterogeneity by modeling study data from all meta-analyses on the standardized mean difference scale. Meta-analysis setting was described according to outcome type, intervention comparison type, and medical area. Predictive distributions for between-study variance expected in future meta-analyses were obtained, which can be used directly as informative priors. Among outcome types, heterogeneity was found to be lowest in meta-analyses of obstetric outcomes. Among intervention comparison types, heterogeneity was lowest in meta-analyses comparing two pharmacologic interventions. Predictive distributions are reported for different settings. In two example meta-analyses, incorporating external evidence led to a more precise heterogeneity estimate. Heterogeneity was influenced by meta-analysis characteristics. Informative priors for between-study variance were derived for each specific setting. Our analyses thus assist the incorporation of realistic prior information into meta-analyses including few studies. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Comparison between triple quadrupole, time of flight and hybrid quadrupole time of flight analysers coupled to liquid chromatography for the detection of anabolic steroids in doping control analysis.

    PubMed

    Pozo, Oscar J; Van Eenoo, Peter; Deventer, Koen; Elbardissy, Hisham; Grimalt, Susana; Sancho, Juan V; Hernandez, Felix; Ventura, Rosa; Delbeke, Frans T

    2011-01-17

    Triple quadrupole (QqQ), time of flight (TOF) and quadrupole-time of flight (QTOF) analysers have been compared for the detection of anabolic steroids in human urine. Ten anabolic steroids were selected as model compounds based on their ionization and the presence of endogenous interferences. Both qualitative and quantitative analyses were evaluated. QqQ allowed for the detection of all analytes at the minimum required performance limit (MRPL) established by the World Anti-Doping Agency (between 2 and 10 ng mL(-1) in urine). TOF and QTOF approaches were not sensitive enough to detect some of the analytes (3'-hydroxy-stanozolol or the metabolites of boldenone and formebolone) at the established MRPL. Although a suitable accuracy was obtained, the precision was unsatisfactory (RSD typically higher than 20%) for quantitative purposes irrespective of the analyser used. The methods were applied to 30 real samples declared positives either for the misuse of boldenone, stanozolol and/or methandienone. Most of the compounds were detected by every technique, however QqQ was necessary for the detection of some metabolites in a few samples. Finally, the possibility to detect non-target steroids has been explored by the use of TOF and QTOF. The use of this approach revealed that the presence of boldenone and its metabolite in one sample was due to the intake of androsta-1,4,6-triene-3,17-dione. Additionally, the intake of methandienone was confirmed by the post-target detection of a long-term metabolite. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Prediction of the thermal environment and thermal response of simple panels exposed to radiant heat

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Ash, Robert L.

    1989-01-01

    A method of predicting the radiant heat flux distribution produced by a bank of tubular quartz heaters was applied to a radiant system consisting of a single unreflected lamp irradiating a flat metallic incident surface. In this manner, the method was experimentally verified for various radiant system parameter settings and used as a source of input for a finite element thermal analysis. Two finite element thermal analyses were applied to a thermal system consisting of a thin metallic panel exposed to radiant surface heating. A two-dimensional steady-state finite element thermal analysis algorithm, based on Galerkin's Method of Weighted Residuals (GFE), was formulated specifically for this problem and was used in comparison to the thermal analyzers of the Engineering Analysis Language (EAL). Both analyses allow conduction, convection, and radiation boundary conditions. Differences in the respective finite element formulation are discussed in terms of their accuracy and resulting comparison discrepancies. The thermal analyses are shown to perform well for the comparisons presented here with some important precautions about the various boundary condition models. A description of the experiment, corresponding analytical modeling, and resulting comparisons are presented.

  10. Regularities in eyewitness identification.

    PubMed

    Clark, Steven E; Howell, Ryan T; Davey, Sherrie L

    2008-06-01

    What do eyewitness identification experiments typically show? We address this question through a meta-analysis of 94 comparisons between target-present and target-absent lineups. The analyses showed that: (a) correct identifications and correct-nonidentifications were uncorrelated, (b) suspect identifications were more diagnostic with respect to the suspect's guilt or innocence than any other response, (c) nonidentifications were diagnostic of the suspect's innocence, (d) the diagnosticity of foil identifications depended on lineup composition, and (e) don't know responses were nondiagnostic with respect to guilt or innocence. Results of diagnosticity analyses for simultaneous and sequential lineups varied for full-sample versus direct-comparison analyses. Diagnosticity patterns also varied as a function of lineup composition. Theoretical, forensic, and legal implications are discussed.

  11. Reanalysis of Korean War Anthropological Records to Support the Resolution of Cold Cases.

    PubMed

    Wilson, Emily K

    2017-09-01

    Re-investigation of previously unidentified remains from the Korean War has yielded 55 new identifications, each with corresponding records of prior anthropological analyses. This study compares biological assessments for age at death, stature, and ancestry across (i) anthropological analyses from the 1950s, (ii) recent anthropological analyses of those same sets of remains, and (iii) the reported antemortem biological information for the identified individual. A comparison of long bone measurements from both the 1950s and during reanalysis is also presented. These comparisons demonstrate commonalities and continuing patterns of errors that are useful in refining both research on Korean War cold case records and forensic anthropological analyses performed using methods developed from the 1950s identifications. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  12. Race and diurnal blood pressure patterns. A review and meta-analysis.

    PubMed

    Profant, J; Dimsdale, J E

    1999-05-01

    Investigators have reported variable findings regarding the role of race in diurnal blood pressure patterns. We performed a review and meta-analysis of this literature to identify the overall effect of race on circadian blood pressure patterns. Eighteen studies involving 2852 participants were reviewed. Meta-analyses were conducted using effect sizes calculated from the data provided directly in the study reports. Separate meta-analyses were conducted on effect sizes for differences between blacks and whites in daytime and nighttime systolic and diastolic blood pressure and nocturnal dip in systolic and diastolic blood pressure. To evaluate discrepancies in findings from studies involving American versus non-American blacks, overall meta-analyses as well as within-subset meta-analyses of black/white differences were conducted for comparisons involving American and non-American blacks. Results of overall meta-analyses indicate that blacks experience higher levels of systolic and diastolic blood pressure, both at night and during the day. These differences were significantly greater at night than during the day (P<0.05). Results of within-subset analyses involving American blacks mirrored those for all black/white comparisons, except that the effect of race on nocturnal dip, ie, that American blacks experienced less of a dip in both systolic and diastolic blood pressure at night, was significant (P<0.05). In contrast, the effect of race on nocturnal dip was not significant for comparisons involving non-American blacks. These results suggest a consistent difference in the chronobiology of blood pressure, particularly in American blacks.

  13. BATMAN-TCM: a Bioinformatics Analysis Tool for Molecular mechANism of Traditional Chinese Medicine.

    PubMed

    Liu, Zhongyang; Guo, Feifei; Wang, Yong; Li, Chun; Zhang, Xinlei; Li, Honglei; Diao, Lihong; Gu, Jiangyong; Wang, Wei; Li, Dong; He, Fuchu

    2016-02-16

    Traditional Chinese Medicine (TCM), with a history of thousands of years of clinical practice, is gaining more and more attention and application worldwide. And TCM-based new drug development, especially for the treatment of complex diseases is promising. However, owing to the TCM's diverse ingredients and their complex interaction with human body, it is still quite difficult to uncover its molecular mechanism, which greatly hinders the TCM modernization and internationalization. Here we developed the first online Bioinformatics Analysis Tool for Molecular mechANism of TCM (BATMAN-TCM). Its main functions include 1) TCM ingredients' target prediction; 2) functional analyses of targets including biological pathway, Gene Ontology functional term and disease enrichment analyses; 3) the visualization of ingredient-target-pathway/disease association network and KEGG biological pathway with highlighted targets; 4) comparison analysis of multiple TCMs. Finally, we applied BATMAN-TCM to Qishen Yiqi dripping Pill (QSYQ) and combined with subsequent experimental validation to reveal the functions of renin-angiotensin system responsible for QSYQ's cardioprotective effects for the first time. BATMAN-TCM will contribute to the understanding of the "multi-component, multi-target and multi-pathway" combinational therapeutic mechanism of TCM, and provide valuable clues for subsequent experimental validation, accelerating the elucidation of TCM's molecular mechanism. BATMAN-TCM is available at http://bionet.ncpsb.org/batman-tcm.

  14. Gender stereotyping in television advertisements: a study of French and Danish television.

    PubMed

    Furnham, A; Babitzkow, M; Uguccioni, S

    2000-02-01

    Two similar, but not identical, content analyses of the portrayals of men and women in French and Danish television advertisements are reported. By partially replicating and extending past investigations conducted in America, Australia, Britain, Hong Kong, Indonesia, Italy, Kenya, and New Zealand, it was predicted that there would be more gender stereotyping in French television advertisements and less gender stereotyping in Danish television advertisements. In the first study, 165 French television advertisements were analyzed by following established coding categories (A. Furnham & E. Skae, 1997; L. Z. McArthur & B. G. Resko, 1975). Contrary to prediction, the results showed that traditional gender role portrayal on French television was no different from that found in other countries. Separate statistical analyses were carried out for visually versus aurally classified central figures, yet this yielded relatively few significant differences. In the second study, a sample of 151 Danish advertisements was analyzed; results showed that Danish television was generally less gender stereotypic than French television in its portrayal of women. Exactly half (5) of the coding categories showed significant differences. Finally, an international statistical comparison between these two studies and similar research in Australia, Britain, and Italy was carried out. The methodological implications of these results are discussed as well as the theoretical issues arising from other studies of this sort.

  15. Reasoning in people with obsessive-compulsive disorder.

    PubMed

    Simpson, Jane; Cove, Jennifer; Fineberg, Naomi; Msetfi, Rachel M; J Ball, Linden

    2007-11-01

    The aim of this study was to investigate the inductive and deductive reasoning abilities of people with obsessive-compulsive disorder (OCD). Following previous research, it was predicted that people with OCD would show different abilities on inductive reasoning tasks but similar abilities to controls on deductive reasoning tasks. A two-group comparison was used with both groups matched on a range of demographic variables. Where appropriate, unmatched variables were entered into the analyses as covariates. Twenty-three people with OCD and 25 control participants were assessed on two tasks: an inductive reasoning task (the 20-questions task) and a deductive reasoning task (a syllogistic reasoning task with a content-neutral and content-emotional manipulation). While no group differences emerged on several of the parameters of the inductive reasoning task, the OCD group did differ on one, and arguably the most important, parameter by asking fewer correct direct-hypothesis questions. The syllogistic reasoning task results were analysed using both correct response and conclusion acceptance data. While no main effects of group were evident, significant interactions indicated important differences in the way the OCD group reasoned with content neutral and emotional syllogisms. It was argued that the OCD group's patterns of response on both tasks were characterized by the need for more information, states of uncertainty, and doubt and postponement of a final decision.

  16. Taste receptors and gustatory associated G proteins in channel catfish, Ictalurus punctatus.

    PubMed

    Gao, Sen; Liu, Shikai; Yao, Jun; Zhou, Tao; Li, Ning; Li, Qi; Dunham, Rex; Liu, Zhanjiang

    2017-03-01

    Taste sensation plays a pivotal role in nutrient identification and acquisition. This is particularly true for channel catfish (Ictalurus punctatus) that live in turbid waters with limited visibility. This biological process is mainly mediated by taste receptors expressed in taste buds that are distributed in several organs and tissues, including the barbels and skin. In the present study, we identified a complete repertoire of taste receptor and gustatory associated G protein genes in the channel catfish genome. A total of eight taste receptor genes were identified, including five type I and three type II taste receptor genes. Their genomic locations, phylogenetic relations, orthologies and expression were determined. Phylogenetic and collinear analyses provided understanding of the evolution dynamics of this gene family. Furthermore, the motif and dN/dS analyses indicated that selection pressures of different degrees were imposed on these receptors. Additionally, four genes of gustatory associated G proteins were also identified. It was indicated that expression patterns of catfish taste receptors and gustatory associated G proteins across organs mirror the distribution of taste buds across organs. Finally, the expression comparison between catfish and zebrafish organs provided evidence of potential roles of catfish skin and gill involved in taste sensation. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Large-Eddy Simulation Comparison of Neutral Flow Over a Canopy: Sensitivities to Physical and Numerical Conditions, and Similarity to Other Representations

    NASA Astrophysics Data System (ADS)

    Ouwersloot, H. G.; Moene, A. F.; Attema, J. J.; de Arellano, J. Vilà-Guerau

    2017-01-01

    The representation of a neutral atmospheric flow over roughness elements simulating a vegetation canopy is compared between two large-eddy simulation models, wind-tunnel data and recently updated empirical flux-gradient relationships. Special attention is devoted to the dynamics in the roughness sublayer above the canopy layer, where turbulence is most intense. By demonstrating that the flow properties are consistent across these different approaches, confidence in the individual independent representations is bolstered. Systematic sensitivity analyses with the Dutch Atmospheric Large-Eddy Simulation model show that the transition in the one-sided plant-area density from the canopy layer to unobstructed air potentially alters the flow in the canopy and roughness sublayer. Anomalously induced fluctuations can be fully suppressed by spreading the transition over four steps. Finer vertical resolutions only serve to reduce the magnitude of these fluctuations, but do not prevent them. To capture the general dynamics of the flow, a resolution of 10 % of the canopy height is found to suffice, while a finer resolution still improves the representation of the turbulent kinetic energy. Finally, quadrant analyses indicate that momentum transport is dominated by the mean velocity components within each quadrant. Consequently, a mass-flux approach can be applied to represent the momentum flux.

  18. Mineralogy and Major Element Abundance of the Dust Particles Recovered from Muses-C Regio on the Asteroid Itokawa

    NASA Technical Reports Server (NTRS)

    Nakamura, T.; Noguchi, T.; Tanaka, M.; Zolensky, M. E.; Kimura, M.; Nakato, A.; Ogami, T.; Ishida, H.; Tsuchiyama, A.; Yada, T.; hide

    2011-01-01

    Remote sensing by the spacecraft Hayabusa suggested that outermost surface particles of Muses-C regio of the asteroid Itokawa consist of centimeter and sub-centimeter size small pebbles. However, particles we found in the sample catcher A stored in the Hayabusa capsule, where Muses-C particles were captured during first touchdown, are much smaller. i.e., most are smaller than 100 microns in size. This suggests that only small fractions of Muses-C particles were stirred up due to the impact of the sampling horn onto the surface, or due to jets from chemical thrusters during the lift off of the spacecraft from the surface. X-ray fluorescence and near-infrared measurements by the Hayabusa spacecraft suggested that Itokawa surface materials have mineral and major element composition roughly similar to LL chondrites. The particles of the Muses-C region are expected to have experienced some effects of space weathering. Both of these prospects can be tested by the direct mineralogical analyses of the returned Itokawa particles in our study and another one. This comparison is most important aspect of the Hayabusa mission, because it finally links chemical analyses of meteorites fallen on the Earth to spectroscopic measurements of the asteroids.

  19. A variational assimilation method for satellite and conventional data: Development of basic model for diagnosis of cyclone systems

    NASA Technical Reports Server (NTRS)

    Achtemeier, G. L.; Ochs, H. T., III; Kidder, S. Q.; Scott, R. W.; Chen, J.; Isard, D.; Chance, B.

    1986-01-01

    A three-dimensional diagnostic model for the assimilation of satellite and conventional meteorological data is developed with the variational method of undetermined multipliers. Gridded fields of data from different type, quality, location, and measurement source are weighted according to measurement accuracy and merged using least squares criteria so that the two nonlinear horizontal momentum equations, the hydrostatic equation, and an integrated continuity equation are satisfied. The model is used to compare multivariate variational objective analyses with and without satellite data with initial analyses and the observations through criteria that were determined by the dynamical constraints, the observations, and pattern recognition. It is also shown that the diagnoses of local tendencies of the horizontal velocity components are in good comparison with the observed patterns and tendencies calculated with unadjusted data. In addition, it is found that the day-night difference in TOVS biases are statistically different (95% confidence) at most levels. Also developed is a hybrid nonlinear sigma vertical coordinate that eliminates hydrostatic truncation error in the middle and upper troposphere and reduces truncation error in the lower troposphere. Finally, it is found that the technique used to grid the initial data causes boundary effects to intrude into the interior of the analysis a distance equal to the average separation between observations.

  20. Comparison of Oregon state highway division Table-1 and Table-2 asphalt : final report.

    DOT National Transportation Integrated Search

    1991-12-01

    The objective of this study was to compare the effect of using the Oregon State Highway Division (OSHD) modified Table-1 asphalts and the OSHD modified Table-2 asphalts in asphalt concrete; the primary factors for comparison were reflective and therm...

  1. Results and evaluation of key comparison CCM.P-K12.1 for very low helium flow rates (leak rates)

    NASA Astrophysics Data System (ADS)

    Šetina, Janez; Vičar, Martin; Pražák, Dominik

    2015-01-01

    The Czech Metrology Institute (CMI) took part and failed to prove equivalence in the Key Comparison CCM.P-K12 of helium leak artefacts (leak rates) into vacuum. After identifying and eliminating the cause of the failure, the Institute of Metals and Technology (IMT) of Slovenia, a successful participant in CCM.P-K12, volunteered to serve as pilot and link in a following bilateral comparison of IMT and CMI that obtained designation CCM.P-K12.1 in June 2012. It was decided to perform the comparison with a glass permeation helium leak artefact at nominally 3.10-11 mol/s (7.4.10-7 mbar.L.s-1) at 23 °C. Both the laboratory standards took part in CCM.P-K12 and were considered as primary. The comparison measurements were performed in October 2012. CMI proved equivalence both with IMT and with the reference value of the key comparison CCM.P-K12. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Subsequent bilateral comparison to CCT-K3, CIPM key comparison CCT-K3.1: Comparison of standard platinum resistance thermometers at the triple point of water (T = 273.16 K) and at the melting point of gallium (T = 302.9146 K)

    NASA Astrophysics Data System (ADS)

    Picard, S.; Nonis, M.; Solve, S.; Allisy-Roberts, P. J.; Renaot, E.; Martin, C.

    2011-01-01

    A comparison of standard platinum resistance thermometers (SPRTs) has been carried out between the BIPM and the Laboratoire commun de métrologie LNE-CNAM using the melting point of gallium and the triple point of water. The temperature difference at Ga between the BIPM and the LNE-CNAM was determined as 108 µK with an associated combined standard uncertainty of 223 µK. This outcome indicates a present temperature difference of the BIPM of -65 µK with respect to an Average Reference Value from an earlier comparison, with an associated uncertainty of uc = 262 µK. It should be noted that the present BIPM scale is not independent, but traceable to cells used in KC7. The comparison results validate the re-establishment of thermometer calibrations at the BIPM for internal use. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. CCQM-K104 key comparison (avermectin B1a) on the characterization of organic substances for chemical purity

    NASA Astrophysics Data System (ADS)

    Dai, Xinhua; Zhang, Wei; Li, Hongmei; Huang, Ting; Li, Mengwan; Quan, Can; Zhang, Qinghe; Davies, Stephen R.; Warren, John; Lo, Man-fung; Kakoulides, Elias; Ceyhan Gören, Ahmet; Marbumrung, Sornkrit; Pfeifer, Dietmar; Ün, İlker; Gündüz, Simay; Yilmaz, Hasibe; Kankaew, Pornhatai; Sudsiri, Nittaya; Shearman, Kittiya; Pookrod, Preeyaporn; Polzer, Joachim; Radeck, Wolfgang

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K104, was coordinated by the National Institute of Metrology (NIM). The comparison was designed to demonstrate a laboratory's performance in determining the mass fraction of the main component in a complex high purity organic material. Nine NMIs or DIs participated in the comparison. Eight participants reported their results. An additional impurity was resolved from the avermectin B1a peak and was tentatively identified as an unknown impurity by NMIA (National Measurement Institute (Australia)). It was subsequently identified by NIM as a diastereoisomer of avermectin B1a at the C-26 position. Final reference value (KCRV) = 924.63 mg/g, with uncertainty (k=1) = 3.89 mg/g, and expanded uncertainty = 8.97 mg/g. The degrees of equivalence with the avermectin B1a KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of high structural complexity (relative molecular mass range of 500 Da -1000 Da and low polarity (-log KOW <= -2). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  4. Final report on the key comparison, CCM.M.P-K15.1 in the pressure range from 1.0 × 10-4 Pa to 1.0 Pa

    NASA Astrophysics Data System (ADS)

    Wuethrich, Christian; Hongyan, Yu

    2017-01-01

    At the CCM WG-LP meeting in Berlin in April 2011 the National Institute of Metrology of the people's republic of China asked for an opportunity to be linked to the CCM.M.P-K15 comparison which just ended. METAS, which had been active as pilot for the CCM.M.P-K15, agreed to make a link with NIM. The NIM introduced a new static expansion system in his laboratory. Two spinning rotor gauges and a control electronic are used as transfer standard. The circulation of the transfer standard was made in spring 2012. The drift of the accommodation coefficient of the two SRG was measured by the pilot before and after the comparison. The stability of the transfer standards was excellent and the equivalence between METAS and NIM has been demonstrated. A link to the CCM.M.P­K15 has been established using the results from METAS. It has been possible to achieve a link with a small uncertainty due to the strong correlation of the measurements of METAS in the two comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. CCM.FF-K3.2011: Final report for the CIPM key comparison of air speed, 0.5 m/s to 40 m/s

    NASA Astrophysics Data System (ADS)

    Müller, Harald; Caré, Isabelle; Lucas, Peter; Pachinger, Dietmar; Kurihara, Noboru; Lishui, Cui; Su, Chun-Min; Shinder, Iosif; Spazzini, Pier Giorgio

    2017-01-01

    The CCM.FF-K3.2011 comparison was organized for the purpose of determination of the degree of equivalence of the national standards for air speed over the range 0.5 m/s to 40 m/s. An ultrasonic anemometer and a Laser Doppler anemometer were used as transfer standards. Nine laboratories from three RMOs participated between July 2013 and July 2015—EURAMET: PTB, Germany; LNE-CETIAT, France; INRIM, Italy; VSL, The Netherlands; E+E, Austria; SIM: NIST, USA; APMP: NMIJ/AIST, Japan; NIM, China; CMS/ITRI, Chinese Taipei. The measurements were provided at ambient conditions. All results of independent participants were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each air speed separately following `procedure A' presented by M G Cox. The degree of equivalence with the KCRV was calculated for each air speed and laboratory. Almost all reported results were consistent with the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Final report on COOMET.QM-K76 (COOMET project no 484/RU/09): Key comparison of primary standard gas mixtures: SO2 in nitrogen (100 µmol/mol)

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Kustikov, Y. A.; Kolobova, A. V.; Shor, N. B.; Efremova, O. V.; Rozhnov, M. S.; Melnyk, D. M.; Kozia, V. G.; Shpilnyi, S. A.; Petryshyn, P. V.; Iakubov, S. E.; Kluchits, A. S.; Ananyin, V. N.; Mironchik, A. M.; Mokhnach, M. V.; Valkova, M.; Stovcik, V.

    2014-01-01

    Sulfur dioxide is one of the main contaminants present in the atmosphere due to burning of coal, oil and natural gas, smelting of base metals and production of sulfuric acid. Sulfur dioxide has been the subject of three previous CCQM key comparisons: CCQM-K1.d in 1997, CCQM-K26.b in 2005 and CCQM-K76 in 2010. VNIIM proposed a new COOMET project (No 484/RU/09) in this field, which was registered in the KCDB as key comparison COOMET.QM-K76. It was found that all results were consistent with the reference (gravimetric) values, with observed differences not exceeding ±0.60% and not exceeding either the appropriate assigned expanded uncertainties. VNIIM is the linking laboratory to CCQM-K76. SMU has improved the results obtained in CCQM-K76. The mixtures prepared for this exercise were found to be stable during about one year within the uncertainty of the measurements. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Final report of APMP.QM-S6: clenbuterol in porcine meat

    NASA Astrophysics Data System (ADS)

    Sin, D. W.-M.; Ho, C.; Yip, Y.-C.

    2016-01-01

    At the CCQM Organic Analysis Working Group (OAWG) Meeting held in April 2012 and the APMP TCQM Meeting held in November 2012, an APMP supplementary comparison (APMP.QM-S6) on the determination of clenbuterol in porcine meat was supported by the OAWG and APMP TCQM. This comparison was organized by the Government Laboratory, Hong Kong. In order to accommodate a wider participation, a pilot study (APMP.QM-P22) was run in parallel to APMP.QM-S6. This study provided the means for assessing the measurement capabilities for determination of low-polarity measurands in a procedure that requires extraction, clean-up, analytical separation, and selective detection in a food matrix. A total of 7 institutes registered for the supplementary comparison and 6 of them submitted their results. 4 results were included for SCRV calculation. All participating laboratories applied Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry (ID-LCMS/MS) technique with clenbuterol-d9 as internal standard spiked for quantitation in this programme. KEY WORDS FOR SEARCH APMP.QM-S6 and Clenbuterol Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. KEY COMPARISON: Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays

    NASA Astrophysics Data System (ADS)

    Allisy-Roberts, P. J.; Kessler, C.; Burns, D. T.; Berlyand, V.; Berlyand, A.

    2010-01-01

    A new comparison of the standards for absorbed dose to water of the All-Russian Scientific Research Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Russia and of the Bureau International des Poids et Mesures (BIPM) has been made in 60Co gamma radiation in 2009. The results show that the VNIIFTRI and the BIPM standards for absorbed dose to water are in agreement, yielding a mean ratio of 0.9976 for the calibration coefficients of the transfer chambers, the difference from unity being within the combined standard uncertainty (0.0043) for this result. This result is consistent with the earlier 2001 comparison result of 0.9967 (43). The updated degrees of equivalence for the VNIIFTRI are compared with those of the other national metrology institutes as presented in the BIPM key comparison database. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. KEY COMPARISON: Final report on CCQM-K57: Chemical composition of clay

    NASA Astrophysics Data System (ADS)

    Salas, Antonio; Ramírez, Estele

    2009-01-01

    After the successful completion of the pilot study, CCQM-P65 [1], the Inorganic Analysis Working Group of CCQM agreed to conduct key comparison CCQM-K57, Chemical composition of clay, in Paris, April 2006. The natural mass fraction levels of five elements—Si, Ca, Fe, Al and Mg—were measured and reported as oxides in clay. Six national metrology institutes participated in CCQM K57, and CENAM (Querétaro, Mexico) coordinated. The methods employed were isotope dilution mass spectrometry (IDMS), inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-optical emission spectrometry (ICP-OES) using the dehydration method and condensation method, gravimetric analysis, neutron activation analysis (NAA), prompt gamma activation analysis (PGAA) and x-ray fluorescence spectrometry (XRF) with the reconstitution method and external calibration. This final report presents the capability of the participant institutes, based on the KCRV, which was approved at the IAWG spring meeting in 2008, and the equivalence statements regarding the KCRV, approved at its autumn meeting. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  10. A preliminary comparison between TOVS and GOME level 2 ozone data

    NASA Astrophysics Data System (ADS)

    Rathman, William; Monks, Paul S.; Llewellyn-Jones, David; Burrows, John P.

    1997-09-01

    A preliminary comparison between total column ozone concentration values derived from TIROS Operational Vertical Sounder (TOVS) and Global Ozone Monitoring Experiment (GOME) has been carried out. Two comparisons of ozone datasets have been made: a) TOVS ozone analysis maps vs. GOME level 2 data; b) TOVS data located at Northern Hemisphere Ground Ozone Stations (NHGOS) vs. GOME data. Both analyses consistently showed an offset in the value of the total column ozone between the datasets [for analyses a) 35 Dobson Units (DU); and for analyses b) 10 DU], despite a good correlation between the spatial and temporal features of the datasets. A noticeably poor correlation in the latitudinal bands 10°/20° North and 10°/20° South was observed—the reasons for which are discussed. The smallest region which was statistically representative of the ozone value correlation dataset of TOVS data at NHGOS and GOME level-2 data was determined to be a region that was enclosed by effective radius of 0.75 arc-degrees (83.5km).

  11. Evaluation and inter-comparison of modern day reanalysis datasets over Africa and the Middle East

    NASA Astrophysics Data System (ADS)

    Shukla, S.; Arsenault, K. R.; Hobbins, M.; Peters-Lidard, C. D.; Verdin, J. P.

    2015-12-01

    Reanalysis datasets are potentially very valuable for otherwise data-sparse regions such as Africa and the Middle East. They are potentially useful for long-term climate and hydrologic analyses and, given their availability in real-time, they are particularity attractive for real-time hydrologic monitoring purposes (e.g. to monitor flood and drought events). Generally in data-sparse regions, reanalysis variables such as precipitation, temperature, radiation and humidity are used in conjunction with in-situ and/or satellite-based datasets to generate long-term gridded atmospheric forcing datasets. These atmospheric forcing datasets are used to drive offline land surface models and simulate soil moisture and runoff, which are natural indicators of hydrologic conditions. Therefore, any uncertainty or bias in the reanalysis datasets contributes to uncertainties in hydrologic monitoring estimates. In this presentation, we report on a comprehensive analysis that evaluates several modern-day reanalysis products (such as NASA's MERRA-1 and -2, ECMWF's ERA-Interim and NCEP's CFS Reanalysis) over Africa and the Middle East region. We compare the precipitation and temperature from the reanalysis products with other independent gridded datasets such as GPCC, CRU, and USGS/UCSB's CHIRPS precipitation datasets, and CRU's temperature datasets. The evaluations are conducted at a monthly time scale, since some of these independent datasets are only available at this temporal resolution. The evaluations range from the comparison of the monthly mean climatology to inter-annual variability and long-term changes. Finally, we also present the results of inter-comparisons of radiation and humidity variables from the different reanalysis datasets.

  12. International comparison CCQM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, Adriaan M. H.; Wouter van der Hout, J.; Ziel, Paul R.; Oudwater, Rutger J.; Fioravante, Andreia L.; Augusto, Cristiane R.; Coutinho Brum, Mariana; Uehara, Shinji; Akima, Dai; Bae, Hyun Kil; Kang, Namgoo; Woo, Jin-Chun; Liaskos, Christina E.; Rhoderick, George C.; Jozela, Mudalo; Tshilongo, James; Ntsasa, Napo G.; Botha, Angelique; Brewer, Paul J.; Brown, Andrew S.; Bartlett, Sam; Downey, Michael L.; Konopelko, L. A.; Kolobova, A. V.; Pankov, A. A.; Orshanskaya, A. A.; Efremova, O. V.

    2017-01-01

    This key comparison aims to assess the core capabilities of the participants in gas analysis. Such competences include, among others, the capabilities to prepare primary standard gas Mixtures (PSMs), perform the necessary purity analysis on the materials used in the gas mixture preparation, the verification of the composition of newly prepared PSMs against existing ones, and the capability of calibrating the composition of a gas mixture. According to the Strategy for Key Comparisons of the Gas Analysis Working Group, this key comparison is classified as a track A key comparison, which means that the results of this key comparison can be used to underpin calibration and measurement capabilities using the flexible scheme, and for propane under the default scheme. The artefacts were binary mixtures of propane in nitrogen at a nominal amount-of-substance fraction level of 1000 μmol/mol. The values and uncertainties from the gravimetric gas mixture preparation were used as key comparison reference values (KCRVs). Each transfer standard had its own KCRV. The results are generally good. All results but one are within +/- 0.2 % of the KCRV. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Solve, S.; Chayramy, R.; Stock, M.

    2011-01-01

    As a part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from March to April 2011. Two BIPM Zener diode-based travelling standards (Fluke 732B) were transported by freight to NSAI-NML. At NSAI-NML, the 10 V output EMF of each travelling standard was measured by direct comparison with a group of characterized Zener diode-based electronic voltage standards. At the BIPM, the travelling standards were calibrated before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages on internal temperature and ambient pressure. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated expanded uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  14. Elements in human serum—CCQM-K139

    NASA Astrophysics Data System (ADS)

    Shin, Richard; Dewi, Fransiska; Tong, Benny; Wah, Leung Ho; Saxby, David; Armishaw, Paul; Ivanova, Veronika; Feng, Liuxing; Wang, Jun; Estela del Castillo Busto, M.; Fisicaro, Paola; Rienitz, Olaf; Fung, Wai-Hong; Ho-pan Yau, Michael; Yim, Yong-Hyeon; Buzoianu, Mirella; Can, Suleyman Z.; Ari, Betul; Cankur, Oktay; Goenaga Infante, Heidi; Pérez-Zambra, Ramiro; Ferreira, Elizabeth; Long, Stephen

    2018-01-01

    Elements in human serum serve as important biomarkers and their levels reflect the well-being of an individual. Electrolytes such as sodium (Na) and chloride (Cl) are crucial in maintaining the normal distribution of water, osmotic pressure and electrical neutrality in the body. Trace element such as copper (Cu) plays a part in many oxidation-reduction reactions and metalloenzymes. The majority of selenium (Se) exists as selenoproteins which are cofactors in the glutathione peroxidase activity that protects the body against free radicals. Phosphorus (P) is required for strong bones and teeth. It is also indispensable for growth, maintenance and repair of tissues and cells. The key comparison CCQM-K139: elements in human serum was coordinated by the Health Sciences Authority, Singapore. This comparison aimed to enable participating National Metrology Institutes (NMIs) and Designated Institutes (DIs) to demonstrate their competence in the determination of elements (electrolytes and essential elements) in human serum. The five measurands (Na, Cl, Cu, Se and P) selected for this comparison were not covered in the last two comparisons in the clinical area (CCQM-K14 and CCQM-K107) and offered different analytical challenges. Their concentration levels were within the normal biological range. They were also within the range of existing calibration and measurement capability (CMC) claims in the International Bureau of Weights and Measures' Key Comparison Database (BIPM KCDB). Ten institutes participated in the comparison for Na, eight for Cl, eleven for Cu, six for Se and eight for P. For the analysis of Na, Cu, Se and P, most of the participating institutes employed microwave-assisted digestion and acid digestion (with or without heating) sample dissolution. For the analysis of Cl, in addition to the microwave-assisted digestion and acid digestion, a wider variety of techniques were employed. These included matrix separation, alkaline extraction and coulometric titration. Inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES) were the two most commonly used instrumental techniques. Other techniques used included ion chromatography (IC), flame atomic absorption spectrometry (FAAS), titration and micro-coulometry. The medians were used as the estimators of Key Comparison Reference Values (KCRVs) for all measurands. The KCRVs (+/- standard uncertainty) for Na, Cl, Cu, Se and P (in mg/kg) were 3346 (+/- 14), 3871 (+/- 22), 1.151 (+/- 0.007), 0.1292 (+/- 0.0007) and 125.70 (+/- 0.35), respectively. The k-factor of 2 was used for the estimation of the expanded uncertainties of the KCRVs. The degree of equivalence and its associated uncertainty were calculated for each submitted result. For the five measurands, most participating institutes were able to demonstrate their capabilities in the determination of elements in human serum. CMC claims based on elements covered in this study may include other elements with similar core competencies, such as zinc (Zn), potassium (K), magnesium (Mg), calcium (Ca) and iron (Fe), in a wide range of biological materials. The measurands should be at similar concentration range and analysed using the same measurement technique(s) applied in this key comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. The Relationship between Affective Response to Social Comparison and Academic Performance in High School

    ERIC Educational Resources Information Center

    Wehrens, Maike J. P. W.; Buunk, Abraham P.; Lubbers, Miranda J.; Dijkstra, Pieternel; Kuyper, Hans; van der Werf, Greetje P. C.

    2010-01-01

    The goal of the present study was to study the relationship between affective responses to social comparison and test scores among high school students. Our analyses showed that three types of responses to social comparison could be distinguished: an empathic, constructive, and destructive response. Whereas girls scored higher on empathic…

  16. Electric chiller handbook. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-02-01

    Electric chillers have dominated the market for large commercial cooling systems due to their history of reliable, economical operation. The phaseout of CFCs and deregulation of the utility industry are two factors that significantly impact the chiller market. The CFC phaseout is resulting in the upgrading or replacement of thousands of electric chillers nationwide. In a deregulated environment, utilities are finding increasing need to provide services that can win and retain new customers. Utility representatives need current information on applying and selecting cost-effective chiller systems. The objective of this report was to develop a comprehensive handbook that helps utility technicalmore » and marketing staff, their customers, and design professionals evaluate and select the best options for chilled-water systems in commercial buildings. Investigators used a variety of industry data sources to develop market-share information for electric and gas chiller systems and to determine applications according to building age, type, and region. Discussions with chiller manufacturers provided information on product availability, performance, and ownership cost. Using EPRI`s COMTECH software, investigators performed comprehensive cost analyses for placement of large and small chillers in three representative cities. Case studies of actual installations support these analyses. Electric Chiller Handbook provides a single source of current information on all major issues associated with chiller selection and application. Key issues include chiller availability and markets, rated performance, future viability of various refrigerant options, the cost-effectiveness of alternative chillers, and chilled-water system optimization. The Handbook also describes available hardware, outlines the features and costs of gas-fired competitive systems, and provides methods and comparisons of life-cycle costing of various chiller system options. Analyses of chiller features and economics show that electric chillers are preferable to gas chillers in the large majority of applications, consistent with current market trends. Furthermore, today`s chillers offer a wide range of efficiencies and refrigerant options to serve cooling system needs for the 20-year lifetime of the chiller. Finally, new higher-efficiency models of electric chillers offer very attractive paybacks.« less

  17. KEY COMPARISON: Final report on CCQM-K9.2: Subsequent key comparison on pH determination of phosphate buffer by Harned cell measurements

    NASA Astrophysics Data System (ADS)

    Spitzer, Petra; Giera, Janine; Fraga, Isabel C.; Tønnes Jakobsen, Pia; Jensen, Hans D.; Hyllested, Peter; Karpov, Oleg; Kutovoy, Viatcheslav; Nakamura, Susumu; Vospelova, Alena; Zvezdina, Valentina

    2008-01-01

    CCQM-K9.2 was performed supplementary to the key comparison CCQM-K9 on the pH determination of a phosphate buffer with nominal pH ~ 6.9 (at 25 °C). The sample composition was very similar in both comparisons. Only the source of the starting material used for sample preparation was different. The comparison was restricted to the use of the primary method for pH (Harned cell measurement) as defined in the IUPAC Recommendations [2]. The measurement temperatures were 15 °C, 25 °C, 37 °C. CCQM-K9.2, CCQM-K.9 and the first supplementary comparison CCQM-K9.1 [5] are activities of the Electrochemical Working Group (EAWG) of the CCQM. All three comparisons were coordinated by the PTB, Germany. The Danish Primary Laboratory (DPL) successfully took part in the CCQM-K9. Meanwhile the primary set-up for pH in Denmark moved from DPL affiliated to Radiometer Medical to DFM, Denmark. The subsequent comparison allows assessing the degree of equivalence for the measurement of pH at DFM after the move. Due to the interest of other laboratories in demonstrating their progress in pH measurements on the primary level the CCQM-K9.2 supplementary comparison was extended to other participants than DFM, namely NMIJ, VNIIFTRI, INMETRO and CMI. The reported quantity for CCQM-K9.2 was not the pH of the sample but the acidity function at zero chloride molality (see chapter 12). To calculate the pH value from the acidity function it is necessary to know the ionic strength of the sample buffer solution, which was undisclosed by the coordinator. With the exception of the Czech Metrology Institute, CMI, good agreement in the determined acidity function is found between the participants. The results reported by DFM and by PTB agree within their measurement uncertainty at all measurement temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Power, O.; Chayramy, R.; Solve, S.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out from January to February 2013. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_8 (Z8) and BIPM_9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (electromotive force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 February 2013. UNML - UBIPM = -0.63 µV uc = 1.31 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Abdel Mageed, Hala M.; Aladdin, Omar M.; Raouf, M. Helmy A.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMB (ZB) and BIPMC (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, UNIS, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 7 September 2014. UNIS - UBIPM = 0.09 µV uc = 0.08 µV, at 1 V UNIS - UBIPM = 0.22 µV uc = 0.14 µV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM, March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2014-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland-National Metrology Laboratory (NSAI-NML), Dublin, Ireland, was carried out in February and March 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_4 (Z4) and BIPM_5 (Z5), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the value assigned to DC voltage standard by NSAI-NML, at the level of 10 V, at NSAI-NML, UNML, and that assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 10 March 2014. UNML - UBIPM = -0.64 µV uc = 1.35 µV, at 10 V where uc is thecombined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML,based on KJ-90, and the uncertainty related to the comparison. The comparison results show that the voltage standards maintained by NSAI-NML and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Anthocyanin analyses of Vaccinium fruit dietary supplements

    USDA-ARS?s Scientific Manuscript database

    Vaccinium fruit ingredients within dietary supplements were identified by comparisons with anthocyanin analyses of known Vaccinium profiles (demonstration of anthocyanin fingerprinting). Available Vaccinium supplements were purchased and analyzed; their anthocyanin profiles (based on HPLC separation...

  2. Final report of the APMP water flow key comparison: APMP.M.FF-K1

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.

    2011-01-01

    The key comparison, APMP.M.FF-K1, was undertaken by APMP/TCFF, the Technical Committee for Fluid Flow (TCFF) under the Asia Pacific Metrology Program (APMP). One objective of the key comparison was to demonstrate the degree of equivalence among six participating laboratories (KRISS, NMIJ, VMI, CMS, NIM and VNIIM) in water flow rate metrology by comparing the results with the key comparison reference value (KCRV) determined from the CCM.FF-K1 key comparison. The other objective of this key comparison was to provide supporting evidence for the calibration and measurement capabilities (CMCs), which had been declared by the participating laboratories during this key comparison. The Transfer Standard Package (TSP) was a Coriolis mass flowmeter, which had been used in the CCM.FF-K1 key comparison. Because the K-factors in the APMP.M.FF-K1 key comparison were slightly lower than the K-factors of the CCM.FF-K1 key comparison due to long-term drifts of the TSP, a correction value D was introduced. The value of D was given by a weighted sum between two link laboratories (NMIJ and KRISS), which participated in both the CCM.FF-K1 and the APMP.M.FF-K1 key comparisons. By this correction, the K-factors were laid between 12.004 and 12.017 at either low (Re = 254 000) or high (Re = 561 000) flow rates. Most of the calibration data were within expected uncertainty bounds. However, some data showed undulations, which gave large fluctuations of the metering factor at Re = 561 000. Calculation of degrees of equivalence showed that all the participating laboratories had deviations between -0.009 and 0.007 pulses/kg from the CCM.FF-K1 KCRV at either the low or the high flow rates. In case of En calculation, all the participating laboratories showed values less than 1, indicating that the corrected K-factors of all the laboratories were equivalent with the KCRV at both Re = 254 000 and 561 000. When the corrected K-factors from two participating laboratories were compared, all the numbers of equivalence showed values less than 1, indicating equivalence. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. Fleet DNA: Commercial Fleet Vehicle Operating Data | Transportation

    Science.gov Websites

    and Vehicle Dynamometer Evaluation and Comparison of Class 7 Hybrid Electric and Conventional Diesel Gasoline-Electric Hybrid Transit Buses In-Use Performance Comparison of Hybrid Electric, CNG, and Diesel Diesel Electric Hybrid Tractor Evaluation: 13-Month Final Report Project Startup: Evaluating Coca-Cola's

  4. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S1

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S2

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Using Inequality Measures to Incorporate Environmental Justice into Regulatory Analyses

    PubMed Central

    Harper, Sam; Ruder, Eric; Roman, Henry A.; Geggel, Amelia; Nweke, Onyemaechi; Payne-Sturges, Devon; Levy, Jonathan I.

    2013-01-01

    Formally evaluating how specific policy measures influence environmental justice is challenging, especially in the context of regulatory analyses in which quantitative comparisons are the norm. However, there is a large literature on developing and applying quantitative measures of health inequality in other settings, and these measures may be applicable to environmental regulatory analyses. In this paper, we provide information to assist policy decision makers in determining the viability of using measures of health inequality in the context of environmental regulatory analyses. We conclude that quantification of the distribution of inequalities in health outcomes across social groups of concern, considering both within-group and between-group comparisons, would be consistent with both the structure of regulatory analysis and the core definition of environmental justice. Appropriate application of inequality indicators requires thorough characterization of the baseline distribution of exposures and risks, leveraging data generally available within regulatory analyses. Multiple inequality indicators may be applicable to regulatory analyses, and the choice among indicators should be based on explicit value judgments regarding the dimensions of environmental justice of greatest interest. PMID:23999551

  7. 77 FR 66471 - Methodology for Designation of Frontier and Remote Areas

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-05

    ... the use of a shorter, more intuitively appealing descriptive label in research publications and other...) Selection of final methodological approach; and (8) Analyses using final methodology on 2000 data. All the...

  8. Reporting of analyses from randomized controlled trials with multiple arms: a systematic review.

    PubMed

    Baron, Gabriel; Perrodeau, Elodie; Boutron, Isabelle; Ravaud, Philippe

    2013-03-27

    Multiple-arm randomized trials can be more complex in their design, data analysis, and result reporting than two-arm trials. We conducted a systematic review to assess the reporting of analyses in reports of randomized controlled trials (RCTs) with multiple arms. The literature in the MEDLINE database was searched for reports of RCTs with multiple arms published in 2009 in the core clinical journals. Two reviewers extracted data using a standardized extraction form. In total, 298 reports were identified. Descriptions of the baseline characteristics and outcomes per group were missing in 45 reports (15.1%) and 48 reports (16.1%), respectively. More than half of the articles (n = 171, 57.4%) reported that a planned global test comparison was used (that is, assessment of the global differences between all groups), but 67 (39.2%) of these 171 articles did not report details of the planned analysis. Of the 116 articles reporting a global comparison test, 12 (10.3%) did not report the analysis as planned. In all, 60% of publications (n = 180) described planned pairwise test comparisons (that is, assessment of the difference between two groups), but 20 of these 180 articles (11.1%) did not report the pairwise test comparisons. Of the 204 articles reporting pairwise test comparisons, the comparisons were not planned for 44 (21.6%) of them. Less than half the reports (n = 137; 46%) provided baseline and outcome data per arm and reported the analysis as planned. Our findings highlight discrepancies between the planning and reporting of analyses in reports of multiple-arm trials.

  9. The Effectiveness of Tutoring on Developmental English Grades

    ERIC Educational Resources Information Center

    Vick, Nicholas; Robles-Piña, Rebecca A.; Martirosyan, Nara M.; Kite, Valerie

    2015-01-01

    Tutoring is an important form of academic support for developmental education students. A comparison study was conducted to investigate the benefits of tutoring on the final grades for developmental English students who participated in tutoring versus those students who did not. The final grades for three consecutive semesters were analyzed to…

  10. Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Power, O.; Stock, M.

    2016-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in January and February 2016. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM7 (Z7) and BIPM9 (Z9), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V, at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 31 of January 2016. UNML - UBIPM = + 0.22 μV uc = 1.35 μV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Bilateral Comparison of 1 V and 10 V Standards between the SMD (Belgium) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Vlad, D.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Service Métrologie—Metrologische Dienst (SMD), Brussel, Belgium, was carried out from October to November 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to SMD and also back to BIPM. At SMD, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at SMD, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by SMD, at the level of 1.018 V and 10 V, at SMD, USMD, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 5 November 2014. USMD - UBIPM = 0.14 mV; uc = 0.07 mV, at 1 V USMD - UBIPM = 0.09 mV; uc = 0.49 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at SMD, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Bilateral Comparison of 1 V and 10 V Standards between the JV (Norway) and the BIPM, January to February 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Sengebush, F.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the Justervesenet (JV), Kjeller, Norway, was carried out from January to February 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM4 (Z4) and BIPM5 (Z5), were transported by freight to JV and also back to BIPM. At JV, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at JV, withthe Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by JV, at the level of 1.018 V and 10 V, at JV, UJV, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 28 January 2015. UJV - UBIPM = 0.23 μV uc = 0.03 μV , at 1 V UJV - UBIPM = 0.63 μV uc = 0.28 μV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at JV, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Power, O.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - National Metrology Laboratory (NSAI - NML), Dublin, Ireland, was carried out in February and March 2015. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM6 (Z6) and BIPMC (ZC), were transported by freight to NSAI-NML. At NSAI-NML, the reference standard for DC voltage at the 10 V level consists of a group of characterized Zener diode-based electronic voltage standards. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the group standard. At the BIPM the travelling standards were calibrated, before and after the measurements at NSAI-NML, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final resultof the comparison is presented as the difference between the values assigned to DC voltage standards by NSAI - NML, at the level of 10 V,at NSAI - NML, UNML, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 24 February 2015. UNML - UBIPM = - 0.82 mV; uc = 1.35 mV , at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NSAI-NML, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Bilateral Comparison of 1 V and 10 V Standards between the NIMT (Thailand) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

    NASA Astrophysics Data System (ADS)

    Solve, S.; Chayramy, R.; Stock, M.; Pimsut, S.

    2015-01-01

    As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute of Metrology (Thailand), NIMT, was carried out from October to December 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPMA (ZA) and BIPM6 (Z6), were transported by freight to NIMT and back to BIPM. At NIMT, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIMT, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned toDC voltage standards by NIMT, at the level of 1.018 V and 10 V, at NIMT, UNIMT, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of 23 November 2014. UNIMT - UBIPM = 0.16 mV; uc = 0.14 mV, at 1 V UNIMT - UBIPM = - 0.03 mV; uc = 0.11 mV, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIMT, based on KJ-90, and the uncertainty related to the comparison. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Ultra-trace analysis of 41Ca in urine by accelerator mass spectrometry: an inter-laboratory comparison

    PubMed Central

    Jackson, George S.; Hillegonds, Darren J.; Muzikar, Paul; Goehring, Brent

    2013-01-01

    A 41Ca interlaboratory comparison between Lawrence Livermore National Laboratory (LLNL) and the Purdue Rare Isotope Laboratory (PRIME Lab) has been completed. Analysis of the ratios assayed by accelerator mass spectrometry (AMS) shows that there is no statistically significant difference in the ratios. Further, Bayesian analysis shows that the uncertainties reported by both facilities are correct with the possibility of a slight under-estimation by one laboratory. Finally, the chemistry procedures used by the two facilities to produce CaF2 for the cesium sputter ion source are robust and don't yield any significant differences in the final result. PMID:24179312

  16. Angle comparison using an autocollimator

    NASA Astrophysics Data System (ADS)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Final report of the SIM.QM-S7 supplementary comparison, trace metals in drinking water

    NASA Astrophysics Data System (ADS)

    Yang, Lu; Nadeau, Kenny; Gedara Pihillagawa, Indu; Meija, Juris; Grinberg, Patricia; Mester, Zoltan; Valle Moya, Edith; Solís González, Faviola Alejandra; del Rocio Arvizu Torres, María; Yañez Muñoz, Oscar; Velina Lara-Manzano, Judith; Mazzitello, Gisela; Prina, Pedro; Acosta, Osvaldo; Napoli, Romina; Pérez Zambra, Ramiro; Ferreira, Elizabeth; Dobrovolskiy, Vladimir; Aprelev, Aleksei; Stakheev, Aleksei; Frolov, Dmitriy; Gusev, Leonid; Ivanova, Veronika; Näykki, Teemu; Sara-Aho, Timo; Venegas Padilla, Jimmy; Acuña Cubillo, Carlos; Bremmer, Dwyte; Freemantle, Ruel; Taebunpakul, Sutthinun; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Kaewkhomdee, Nattikarn; Thiengmanee, Usana; Tangjit, Tararat; Buzoianu, Mirella; Alejandro Ahumada Forigua, Diego; Abella Gamba, Johanna Paola; Alfredo Chavarro Medina, Luis; Sobina, Egor; Tabatchikova, Tatyana; Alexopoulos, Charalambos; Kakoulides, Elias; Delgado, Mabel; Flores, Liliana; Knox, Saira; Siewlal, Kester; Maharaj, Avinash

    2018-01-01

    SIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance - Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Final design review summary report for the TN-WHC cask and transportation system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kee, A.T.

    1997-01-17

    This document represents comments generated from a review of Transnuclear`s Final Design Package distributed on December 10, 1996 and a review of the Final Design Analysis Report meeting held on December 17 & 18, 1996. The Final design describes desicn features and presents final analyses @j performed to fabricate and operate the system while meeting the Cask/Transportation Functions and Requirements, WHC-SD-SNF-FRD-011, Rev. 0 and specification WHC-S-0396, Rev. 1.

  19. Mass univariate analysis of event-related brain potentials/fields I: a critical tutorial review.

    PubMed

    Groppe, David M; Urbach, Thomas P; Kutas, Marta

    2011-12-01

    Event-related potentials (ERPs) and magnetic fields (ERFs) are typically analyzed via ANOVAs on mean activity in a priori windows. Advances in computing power and statistics have produced an alternative, mass univariate analyses consisting of thousands of statistical tests and powerful corrections for multiple comparisons. Such analyses are most useful when one has little a priori knowledge of effect locations or latencies, and for delineating effect boundaries. Mass univariate analyses complement and, at times, obviate traditional analyses. Here we review this approach as applied to ERP/ERF data and four methods for multiple comparison correction: strong control of the familywise error rate (FWER) via permutation tests, weak control of FWER via cluster-based permutation tests, false discovery rate control, and control of the generalized FWER. We end with recommendations for their use and introduce free MATLAB software for their implementation. Copyright © 2011 Society for Psychophysiological Research.

  20. Comparisons of several aerodynamic methods for application to dynamic loads analyses

    NASA Technical Reports Server (NTRS)

    Kroll, R. I.; Miller, R. D.

    1976-01-01

    The results of a study are presented in which the applicability at subsonic speeds of several aerodynamic methods for predicting dynamic gust loads on aircraft, including active control systems, was examined and compared. These aerodynamic methods varied from steady state to an advanced unsteady aerodynamic formulation. Brief descriptions of the structural and aerodynamic representations and of the motion and load equations are presented. Comparisons of numerical results achieved using the various aerodynamic methods are shown in detail. From these results, aerodynamic representations for dynamic gust analyses are identified. It was concluded that several aerodynamic methods are satisfactory for dynamic gust analyses of configurations having either controls fixed or active control systems that primarily affect the low frequency rigid body aircraft response.

  1. Comparison between measured turbine stage performance and the predicted performance using quasi-3D flow and boundary layer analyses

    NASA Technical Reports Server (NTRS)

    Boyle, R. J.; Haas, J. E.; Katsanis, T.

    1984-01-01

    A method for calculating turbine stage performance is described. The usefulness of the method is demonstrated by comparing measured and predicted efficiencies for nine different stages. Comparisons are made over a range of turbine pressure ratios and rotor speeds. A quasi-3D flow analysis is used to account for complex passage geometries. Boundary layer analyses are done to account for losses due to friction. Empirical loss models are used to account for incidence, secondary flow, disc windage, and clearance losses.

  2. Investigating gender violence in Jamaica.

    PubMed

    Spiring, Fred

    2014-01-01

    As Jamaica moves through implementation of their National Policy on Gender Equality and develops harassment legislation, this article attempts to investigate current levels and trends of gender-based violence in Jamaica. All analyses make use of existing data and data formats in developing performance indicators that illustrate the current state of gender violence in Jamaica. The analyses provide a baseline for the future assessment and comparison with internationally accepted gender-based violence indicators. All source data has been included to facilitate comparisons and discussions regarding related levels and trends of violence as well as addressing performance indicator effectiveness.

  3. Propensity-score matching in economic analyses: comparison with regression models, instrumental variables, residual inclusion, differences-in-differences, and decomposition methods.

    PubMed

    Crown, William H

    2014-02-01

    This paper examines the use of propensity score matching in economic analyses of observational data. Several excellent papers have previously reviewed practical aspects of propensity score estimation and other aspects of the propensity score literature. The purpose of this paper is to compare the conceptual foundation of propensity score models with alternative estimators of treatment effects. References are provided to empirical comparisons among methods that have appeared in the literature. These comparisons are available for a subset of the methods considered in this paper. However, in some cases, no pairwise comparisons of particular methods are yet available, and there are no examples of comparisons across all of the methods surveyed here. Irrespective of the availability of empirical comparisons, the goal of this paper is to provide some intuition about the relative merits of alternative estimators in health economic evaluations where nonlinearity, sample size, availability of pre/post data, heterogeneity, and missing variables can have important implications for choice of methodology. Also considered is the potential combination of propensity score matching with alternative methods such as differences-in-differences and decomposition methods that have not yet appeared in the empirical literature.

  4. International comparison CCQM-K119 liquefied petroleum gas

    NASA Astrophysics Data System (ADS)

    Brewer, P. J.; Downey, M. L.; Atkins, E.; Brown, R. J. C.; Brown, A. S.; Zalewska, E. T.; van der Veen, A. M. H.; Smeulders, D. E.; McCallum, J. B.; Satumba, R. T.; Kim, Y. D.; Kang, N.; Bae, H. K.; Woo, J. C.; Konopelko, L. A.; Popova, T. A.; Meshkov, A. V.; Efremova, O. V.; Kustikov, Y.

    2018-01-01

    Liquefied hydrocarbon mixtures with traceable composition are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas), thus meeting the needs of an increasingly large industrial market. This comparison aims to assess the analytical capabilities of laboratories for measuring the composition of a Liquid Petroleum Gas (LPG) mixture when sampled in the liquid phase from a Constant Pressure Cylinder. Mixtures contained ethane, propane, propene, i-butane, n-butane, but-1-ene and i-pentane with nominal amount fractions of 2, 71, 9, 4, 10, 3 and 1 cmol mol-1 respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. International comparison CCQM-K113—noble gas mixture

    NASA Astrophysics Data System (ADS)

    Lim, Jeong Sik; Lee, Jinbok; Moon, Dongmin; Tshilongo, James; Qiao, Han; Shuguo, Hu; Tiqiang, Zhang; Kelley, Michael E.; Rhoderick, George C.; Konopelko, L. A.; Kolobova, A. V.; Vasserman, I. I.; Zavyalov, S. V.; Gromova, E. V.; Efremova, O. V.

    2017-01-01

    Noble gases are one of the key elements used in the various processes of the bulbs industry, automotive industry, space industry, lasers industry, display industry as well as the semiconductor industry. Considering continuous growth, the provision of a reliable standard is required for those industries to improve their productivity. In this report, a result of the key comparison, CCQM-K113: noble gas mixture, is presented. Nominal amount-of-substance fractions of argon, neon, krypton, and xenon in helium are 20, 10, 2, and 1 cmol/mol, respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Comparison of a 50 mL pycnometer and a 500 mL flask, EURAMET.M.FF.S8 (EURAMET 1297)

    NASA Astrophysics Data System (ADS)

    Mićić, Ljiljana; Batista, Elsa

    2018-01-01

    The purpose of this comparison was to compare the results of the participating laboratories in the calibration of 50 mL pycnometer and 500 mL volumetric flask using the gravimetric method. Laboratories were asked to determined the 'contained' volume of the 50 mL pycnometer and of the 500 mL flask at a reference temperature of 20 °C. The gravimetric method was used for both instruments by all laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Sensing systems efficiency evaluation and comparison for homeland security and homeland defense

    NASA Astrophysics Data System (ADS)

    Pakhomov, Alexander A.

    2010-04-01

    Designers and consumers of various security, intelligence, surveillance and reconnaissance (ISR) systems as well as various unattended ground sensors pay most attention to their commonly used performance characteristics such as probability of a target detection and probability of a false alarm. These characteristics are used for systems comparison and evaluation. However, it is not enough for end-users of these systems as well as for their total/final effectiveness assessment. This article presents and discusses a system approach to an efficiency estimation of the security and ISR systems. Presented approach aims at final result of the system's function and use. It allows setting up reasonable technical and structural requirements for the security and ISR systems, to make trustworthy comparison and practical application planning of such systems. It also allows finding forward-looking, perspective ways of systems development. Presented results can be guidance to both designers and consumers.

  8. Calibration of mass and conventional mass of weights between INACAL-CENAM-CESMEC (SIM.M.M-S13)

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Cori Almonte, Luz Marina; García, Fernando; García, Francisco; Hernández, Raúl; Peña, Luis Manuel; Quiroga Rojas, Aldo; Taipe Araujo, Donny

    2017-01-01

    This supplementary comparison was piloted by the Instituto Nacional de Calidad (INACAL, Peru) and describes the results of the comparison in mass and conventional mass in weights of 2 kg and 10 kg between INACAL-PERU, CENAM-MEXICO and CESMEC-CHILE. The travelling standards were OIML class E2 weights of stainless steel. INACAL measured the volume of the traveling standards of 10 kg and the volume value used for the 2 kg mass standard was provided by the PTB. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Comparison between hadronic final states produced in μ p and e + e - interactions

    NASA Astrophysics Data System (ADS)

    Arneodo, M.; Arvidson, A.; Aubert, J. J.; Badelek, B.; Beaufays, J.; Bee, C. P.; Benchouk, C.; Berghoff, G.; Bird, I.; Blum, D.; Böhm, E.; de Bouard, X.; Brasse, F. W.; Braun, H.; Broll, C.; Brown, S.; Brück, H.; Calen, H.; Chima, J. S.; Ciborowski, J.; Clifft, R.; Coignet, G.; Combley, F.; Coughlan, J.; D'Agostini, G.; Dahlgren, S.; Dengler, F.; Derado, I.; Dreyer, T.; Drees, J.; Düren, M.; Eckardt, V.; Edwards, A.; Edwards, M.; Ernst, T.; Eszes, G.; Favier, J.; Ferrero, M. I.; Figiel, J.; Flauger, W.; Foster, J.; Gabathuler, E.; Gajewski, J.; Gamet, R.; Gayler, J.; Geddes, N.; Grafström, P.; Grard, F.; Haas, J.; Hagberg, E.; Hasert, F. J.; Hayman, P.; Heusse, P.; Jaffré, M.; Jacholkowska, A.; Janata, F.; Jancso, G.; Johnson, A. S.; Kabuss, E. M.; Kellner, G.; Korbel, V.; Krüger, J.; Kullander, S.; Landgraf, U.; Lanske, D.; Loken, J.; Long, K.; Maire, M.; Malecki, P.; Manz, A.; Maselli, S.; Mohr, W.; Montanet, F.; Montgomery, H. E.; Nagy, E.; Nassalski, J.; Norton, P. R.; Oakham, F. G.; Osborne, A. M.; Pascaud, C.; Pawlik, B.; Payre, P.; Peroni, C.; Peschel, H.; Pessard, H.; Pettingale, J.; Pietrzyk, B.; Pönsgen, B.; Pötsch, M.; Renton, P.; Ribarics, P.; Rith, K.; Rondio, E.; Sandacz, A.; Scheer, M.; Schlagböhmer, A.; Schiemann, H.; Schmitz, N.; Schneegans, M.; Scholz, M.; Schröder, T.; Schouten, M.; Schultze, K.; Sloan, T.; Stier, H. E.; Studt, M.; Taylor, G. N.; Thénard, J. M.; Thompson, J. C.; de La Torre, A.; Toth, J.; Urban, L.; Wallucks, W.; Whalley, M.; Wheeler, S.; Williams, W. S. C.; Wimpenny, S. J.; Windmolders, R.; Wolf, G.

    1987-12-01

    A comparison is made between the properties of the final state hadrons produced in 280 GeV μ p interactions and in e + e - annihilation. The Lund model of hadroproduction is used as an aid in understanding the differences observed. The hadron distributions from μ p and e + e - interactions are consistent with the quark parton model assumption of environmental independence, provided that the differences in heavy quark production and hard QCD effects in the two processes are taken into account. A comparison with a K + p experiment is also made. Values are also determined for the Lund model parameters σq = 0.410 ± 0.002 ± 0.020 GeV and σ' = 0.29{-0.15/-0.13 +0.09+0.10} GeV, controlling the transverse momenta in fragmentation and intrinsic transverse momenta of the struck quark respectively.

  10. 49 CFR 268.21 - Down-selection of one or more Maglev projects for further study and selection of one project for...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... further study and selection of one project for final design, engineering, and construction funding. 268.21... and selection of one project for final design, engineering, and construction funding. (a) Upon... analyses necessary prior to initiation of construction. Final design and engineering work will also be...

  11. 49 CFR 268.21 - Down-selection of one or more Maglev projects for further study and selection of one project for...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... further study and selection of one project for final design, engineering, and construction funding. 268.21... and selection of one project for final design, engineering, and construction funding. (a) Upon... analyses necessary prior to initiation of construction. Final design and engineering work will also be...

  12. 49 CFR 268.21 - Down-selection of one or more Maglev projects for further study and selection of one project for...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... further study and selection of one project for final design, engineering, and construction funding. 268.21... and selection of one project for final design, engineering, and construction funding. (a) Upon... analyses necessary prior to initiation of construction. Final design and engineering work will also be...

  13. 49 CFR 268.21 - Down-selection of one or more Maglev projects for further study and selection of one project for...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... further study and selection of one project for final design, engineering, and construction funding. 268.21... and selection of one project for final design, engineering, and construction funding. (a) Upon... analyses necessary prior to initiation of construction. Final design and engineering work will also be...

  14. 49 CFR 268.21 - Down-selection of one or more Maglev projects for further study and selection of one project for...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... further study and selection of one project for final design, engineering, and construction funding. 268.21... and selection of one project for final design, engineering, and construction funding. (a) Upon... analyses necessary prior to initiation of construction. Final design and engineering work will also be...

  15. 77 FR 26444 - Revisions to Final Response To Petition From New Jersey Regarding SO2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... modeling or other technical analyses and no new analyses were necessary to make the revisions. III. Public... this modeling approach. Therefore, no new technical analyses or any changes to the modeling are...) modeling analysis submitted with the September 2010 petition identified NAAQS violations at receptors in...

  16. Efficacy and safety of nebivolol and valsartan as fixed-dose combination in hypertension: a randomised, multicentre study.

    PubMed

    Giles, Thomas D; Weber, Michael A; Basile, Jan; Gradman, Alan H; Bharucha, David B; Chen, Wei; Pattathil, Manoj

    2014-05-31

    The fixed-dose combination of any two antihypertensive drugs from different drug classes is typically more effective in reducing blood pressure than a dose increase of component monotherapy. We assessed the efficacy and safety of a fixed-dose combination of a vasodilating β blocker (nebivolol) and an angiotensin II receptor blocker (valsartan) in adults with hypertension. We did an 8-week, phase 3, multicentre, randomised, double-blind, placebo-controlled, parallel-group trial at 401 US sites. Participants (age ≥18 years) with hypertension but with blood pressure less than 180/110 mm Hg were randomly assigned (2:2:2:2:2:2:2:1) by a 24-h interactive web response system in blocks of 15 to 4 weeks of double-blind treatment with nebivolol and valsartan fixed-dose combination (5 and 80 mg/day, 5 and 160 mg/day, or 10 and 160 mg/day), nebivolol (5 mg/day or 20 mg/day), valsartan (80 mg/day or 160 mg/day), or placebo. Doses were doubled in weeks 5-8; results are reported according to the final dose. Participants and research staff were masked to treatment allocation. The primary and key secondary endpoints were changes from baseline to week 8 in diastolic and systolic blood pressure, respectively. The primary statistical comparison was between the highest fixed-dose combination dose and the highest monotherapy doses; lower doses were then compared if this comparison was positive (Hochberg method for multiple testing). Efficacy analyses were by intention to treat. Safety assessments included monitoring of adverse events. Continuous efficacy parameters were analysed using an ANCOVA model; binary outcomes were analysed using a logistic regression model. This study is registered with ClinicalTrials.gov, NCT01508026. Between Jan 6, 2012, and March 15, 2013, 4161 patients were randomly assigned (277 to placebo and 554-555 to each active comparator group), 4118 of whom were included in the primary analysis. At week 8, the fixed-dose combination 20 and 320 mg/day group had significantly greater reductions in diastolic blood pressure from baseline than both nebivolol 40 mg/day (least-squares mean difference -1·2 mm Hg, 95% CI -2·3 to -0·1; p=0·030) and valsartan 320 mg/day (-4·4 mm Hg, -5·4 to -3·3; p<0·0001); all other comparisons were also significant, favouring the fixed-dose combinations (all p<0·0001). All systolic blood pressure comparisons were also significant (all p<0·01). At least one treatment-emergent adverse event was experienced by 30-36% of participants in each group. Nebivolol and valsartan fixed-dose combination is an effective and well-tolerated treatment option for patients with hypertension. Forest Research Institute. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. International Comparisons of Teachers' Salaries: An Exploratory Study. Survey Report.

    ERIC Educational Resources Information Center

    Barro, Steven M.; Suter, Larry

    This paper, the final product of a study, "International Comparison of Teachers' Salaries," on an exploratory effort to compare salaries of elementary and secondary school teachers in the United States with those in other economically advanced countries. Data was obtained from Canada, Denmark, Federal Republic of Germany, France, Italy, Japan,…

  18. Market-based approaches to tree valuation

    Treesearch

    Geoffrey H. Donovan; David T. Butry

    2008-01-01

    A recent four-part series in Arborist News outlined different appraisal processes used to value urban trees. The final article in the series described the three generally accepted approaches to tree valuation: the sales comparison approach, the cost approach, and the income capitalization approach. The author, D. Logan Nelson, noted that the sales comparison approach...

  19. Using Inequality Measures to Incorporate Environmental Justice into Regulatory Analyses

    EPA Science Inventory

    Abstract: Formally evaluating how specific policy measures influence environmental justice is challenging, especially in the context of regulatory analyses in which quantitative comparisons are the norm. However, there is a large literature on developing and applying quantitative...

  20. On-site comparison of Quantum Hall Effect resistance standards of METAS and the BIPM: Ongoing key comparison BIPM.EM-K12

    NASA Astrophysics Data System (ADS)

    Gournay, Pierre; Rolland, Benjamin; Mortara, Alessandro; Jeanneret, Blaise

    2018-01-01

    An on-site comparison of the quantum Hall effect (QHE) resistance standards of the Federal Institute of Metrology METAS (Switzerland) and of the Bureau International des Poids et Mesures (BIPM) was made in December 2017. Measurements of a 100 Ω standard in terms of the conventional value of the von Klitzing constant, RK-90, agreed to 5 parts in 1010 with a relative combined standard uncertainty uc = 23 × 10‑10. Scaling from 100 Ω to 10 kΩ has also been addressed through the measurement of a 10000 Ω/100 Ω ratio. The measurements carried out agreed to 2 parts in 1010 with a relative combined standard uncertainty uc = 19 × 10‑10. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. COOMET pilot comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 kHz

    NASA Astrophysics Data System (ADS)

    Yi, Chen; Isaev, A. E.; Yuebing, Wang; Enyakov, A. M.; Teng, Fei; Matveev, A. N.

    2011-01-01

    A description is given of the COOMET project 473/RU-a/09: a pilot comparison of hydrophone calibrations at frequencies from 250 Hz to 200 kHz between Hangzhou Applied Acoustics Research Institute (HAARI, China)—pilot laboratory—and Russian National Research Institute for Physicotechnical and Radio Engineering Measurements (VNIIFTRI, Designated Institute of Russia of the CIPM MRA). Two standard hydrophones, B&K 8104 and TC 4033, were calibrated and compared to assess the current state of hydrophone calibration of HAARI (China) and Russia. Three different calibration methods were applied: a vibrating column method, a free-field reciprocity method and a comparison method. The standard facilities of each laboratory were used, and three different sound fields were applied: pressure field, free-field and reverberant field. The maximum deviation of the sensitivities of two hydrophones between the participants' results was 0.36 dB. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV-KCWG.

  2. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    NASA Astrophysics Data System (ADS)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  3. SUPPLEMENTARY COMPARISON: Final report on Supplementary Comparison APMP.M.H-S1

    NASA Astrophysics Data System (ADS)

    Kongkavitool, Rugkanawan; Hattori, Koichiro; Sanh, Vo; Yen, Lim Gin

    2007-01-01

    This report presents the results of supplementary comparison APMP.M.H-S1 among four national metrology institutes (NIMT, NMIJ/AIST, VMI and SPRING). The comparison was carried out during October 2004 to January 2005 in order to determine the capability of the primary Rockwell hardness standard, including standard conditions, of each participant, to confirm the accuracy of Rockwell hardness scale C measurement declared by the participant, which includes the effect of each participant's primary indenter and determine the degrees of equivalence of hardness scale measurement in the range 20 HRC to 60 HRC. Furthermore, the comparison was carried out a by common indenter, which was provided by the pilot institute, in order to determine the measurement capability of the participant's primary machine without the influence of the indenter, as a study of scientific purpose. The pilot institute was the National Institute of Metrology (Thailand), NIMT. There were two sets of artifacts for the comparison. Each set was composed of nine hardness blocks: 20 HRC, 25 HRC, 30 HRC, 35 HRC, 40 HRC, 45 HRC, 50 HRC, 55 HRC, 60 HRC. The verification of the participant's primary Rockwell hardness machine was carried out according to ISO6508-3 before making the measurement. The pilot institute made measurements at the beginning and the end of the comparison in order to monitor the stability of the artifacts. The degree of equivalence of each national primary hardness standard was expressed quantitatively by two terms, the deviation from KCRV and the uncertainty of this deviation at a 95% level of confidence. The En parameter was calculated to express the equivalence between the measurements of participants as well. The degree of equivalence between pairs of participating institutes was expressed by the difference of their deviations from the key comparison reference value and the uncertainty of this difference at the 95% level of confidence. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  4. Simeprevir with pegylated interferon alfa 2a plus ribavirin for treatment of hepatitis C virus genotype 1 in patients with HIV: a meta-analysis and historical comparison.

    PubMed

    Andersohn, Frank; Claes, Anne-Kathrin; Kulp, Werner; Mahlich, Jörg; Rockstroh, Jürgen Kurt

    2016-01-11

    About one third of patients infected with human immunodeficiency virus (HIV) also have chronic hepatitis due to hepatitis C virus (HCV). HCV therapy with simeprevir, pegylated interferon alfa (PegIFNα) and ribavirin (RBV) have been shown to be superior to PegIFNα + RBV alone in non-HIV patients, but no randomized trials in patients with HCV genotype 1 (HCV-1)/HIV coinfection are available. This was a historical comparison of study C212 (simeprevir + PegIFNα-2a + RBV in patients with HCV-1/HIV coinfection) with studies in which HCV-1/HIV coinfected patients were treated with PegIFNα-2a + RBV alone. A systematic literature search was performed to identify eligible studies. Efficacy and safety results of PegIFNα-2a + RBV studies were combined in random- and fixed-effects inverse-variance weighted meta-analyses of proportions using the Freeman-Tukey double arcsin transformation method, and compared with the results of study C212. The literature search revealed a total of 2392 records, with 206 articles selected for full-text review. Finally, 11 relevant articles reporting on 12 relevant study groups were included. Results on sustained virologic response 24 weeks after end of treatment (SVR24) were available from all 12 study groups. Pooled SVR24 for PegIFNα-2a + RBV from the random-effects meta-analysis was 28.2% (95% CI 23.8% to 32.9%). The comparison between study C212 (SVR24 = 72.6%; 95% CI 63.1% to 80.9%) revealed substantial superiority of simeprevir + PegIFNα-2a + RBV compared to PegIFNα-2a + RBV alone, with an absolute risk difference of 45% (95% CI 34 to 55). This finding was robust in a sensitivity analysis that only included historical studies with a planned treatment duration of at least 48 weeks and the same RBV dose as in study C212. No increases in the frequency of important adverse event categories including anemia were identified, but these analyses were limited by the low number of studies. This historical comparison provides first systematic evidence for the superiority of simeprevir + PegIFNα-2a + RBV compared to PegIFNα-2a + RBV in patients with HCV-1/HIV coinfection. Given the limitations of the historical comparison for safety endpoints, additional data on the comparative safety of simeprevir in patients with HCV-1/HIV coinfection would be desirable. Identifier for study TMC435-TiDP16-C212 (ClinicalTrials.gov): NCT01479868.

  5. CCQM-K103 key comparison melanine in milk powder

    NASA Astrophysics Data System (ADS)

    Li, Xiuqin; Zhang, Qinghe; Li, Hongmei; Li, Mengwan; Wong, Siu-kay; Lee, Foo-Wing; Kakoulides, Elias; Naujaus, Evaldas; Fernandes-Whaley, Maria; Prevoo-Franzsen, Des; Quinn, Laura; Pookrod, Preeyaporn; Konopelko, Leonid

    2017-01-01

    Under the Comité Consultatif pour la Quantité de Matière (CCQM), a key comparison, CCQM-K103, was coordinated by the National Institute of Metrology (NIM) and Government Laboratory, Hong Kong, China (GLHK). The comparison was designed to demonstrate NMIs/DIs ability to analyze traces of melamine in milk and milk powder at concentration levels resulting from requirements for food safety. Seven NMIs or DIs participated in the comparison. Final reference value (KCRV) is 0.286 mg/kg, with standard uncertainty of the median as 0.011 mg/kg (3.8 %). The k-factor for the estimation of the expanded uncertainty was chosen as k = 2.57 ( t (0.05;5) ), thus the expanded uncertainty is 0.028 mg/kg (9.8%). The degrees of equivalence with melamine in milk powder KCRV for each participant were reported. The measurement results and degrees of equivalence should be indicative of the performance of a laboratory's measurement capability for IDMS in determining mass fractions in the range from 0.1 to 5.0 mg/kg of analytes with low molar mass (range 50-300 Da) with high polarity (pKow > -2.0) in milk and milk products. Extension to other analytes and matrices should be applied with care since there is a close linkage to other relevant parameters as e.g. sample preparation procedures (liquid/liquid extraction, SPE clean-up) and analytical separation techniques (e.g., GC-MS, LC-MS/MS etc). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. SIM.M.FF-S7: Final report on SIM/ANDIMET supplementary comparison for volume of liquids at 100 mL and 100 μL

    NASA Astrophysics Data System (ADS)

    Trujillo, S.; Maldonado, J. M.; Vega, M. C.; Santalla, E.; Sica, A.; Cantero, D.; Salazar, M.; Morales, A.; Solano, P.; Rodríguez, L. D.

    2016-01-01

    A SIM/ANDIMET comparison for liquid volume using two 100 mL pycnometers and two 100 μL piston pipettes was performed between January 2012 and October 2013. The National Metrology Institute (NMI) of Bolivia was the coordinating laboratory and the Mexican NMI provided technical assistance. The participating labs were IBMETRO (Bolivia), INM (Colombia), INEN (Ecuador), INDECOPI (Peru), LACOMET (Costa Rica), LATU (Uruguay), INTN (Paraguay), and CENAM (Mexico). Based on measurements made by CENAM at the beginning and end of the comparison, the transfer standards were stable during the comparison within 0.0001 mL for the 100 mL pycnometers and 0.03 μL for the 100 μL pipettes. For 100 mL, six of the eight participants agreed within ± 0.003 % and had standardized degrees of equivalence (EN) less than 1. Two participants (INEN and INM) had EN values greater than 1. For the 100 μL pipettes, the results were corrected for the influence of altitude and seven of the eight participants agreed within ± 0.3 %. Results from INEN and some from INM and IBMETRO had EN values greater than 1 for the 100 μL pipettes. Uncertainties recommended by Guideline DKD-R 8-1 for micropipettes were included. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Final report on the supplementary comparison, EURAMET.M.P-S7 (EURAMET project 1040) in the pressure range from 1.10-4 Pa to 0.9 Pa

    NASA Astrophysics Data System (ADS)

    Wüthrich, C.; Alisic, S.; Bergoglio, M.; Saxholm, S.; Lefkopoulos, A.; Pražák, D.; Setina, J.

    2016-01-01

    Many laboratories within EURAMET started a calibration service in medium and high vacuum recently and did not have the opportunity to take part to a comparison before. In order to assess the uncertainty budget and the quality of the measurement of these laboratories, an intercomparison, EURAMET 1040 registered as EURAMET.M.P-S7, from 0.1 mPa to 0.9 Pa has been organised. The participants are the CMI (Czech republic), EIM (Greece), IMT (Slovenia), INRIM (Italy), IMBIH (Bosnia Herzegovinia) and MIKES (Finland) while METAS (Switzerland) is pilot laboratory. Three laboratories (INRIM, CMI and METAS) involved in this work have a primary definition of the pressure. Two spinning rotor gauges and a control electronic are used as transfer standard. The circulation of the transfer standard is organised as a succession of loops with a measurement by the pilot between each participant. A reference value has been determined based on a weighted mean of the results of the primary laboratories. All the participants have demonstrated their equivalence in the definition of the pressure. This comparison has been used as pilot comparison for the CCM.P-K14 project which covers the same scope with similar transfer standards. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Final Report: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo

    2015-01-01

    The EURAMET.M.FF-K6 comparison was organized for the purpose of determination of the degree of equivalence of the primary (national) standards for low-pressure gas flow measurement over the range (2 to 100) m3/h and was performed simultaneously with CCM.FF-K6.2011 with the same transfer standard. A rotary gas meter G65 was used as a transfer standard. The measurements were provided by prescribed reference conditions. Fifteen laboratories from EURAMET participated in this key comparison - SMU, Slovakia; PTB, Germany; CEM, Spain; LNE-LADG, France; VSL, Netherlands; CMI, Czech Republic; BEV, Austria; MKEH, Hungary; GUM Poland; SP, Sweden; METAS, Switzerland; DMDM, Serbia; TUBITAK-UME, Turkey; EIM, Greece; IMBiH, Bosnia-Herzegovina. The EURAMET.M.FF-K6 is linked to the CCM.FF-K6.2011 by correcting the results of three linking laboratories (Slovakia SMU, Germany PTB and France LNE LADG). This correction provides an estimate of what would have been the result from the EURAMET.M-FF-K6 participants, if they had actually participated in CCM.FF-K6.2011. According to the evaluation 93.7 % of the results were consistent with KCRV, 3.4 % of the results were in the warning level and 2.9 % of the results were inconsistent. The results of this comparison can be used for review of the CMC tables. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Final report on key comparison CCQM-K100: Analysis of copper in ethanol

    NASA Astrophysics Data System (ADS)

    Zhou, Tao; Kakoulides, Elias; Zhu, Yanbei; Jaehrling, Reinhard; Rienitz, Olaf; Saxby, David; Phukphatthanachai, Pranee; Yafa, Charun; Labarraque, Guillaume; Cankur, Oktay; Can, Süleyman Z.; Konopelko, Leonid A.; Kustikov, Yu A.; Caciano de Sena, Rodrigo; Marques Rodrigues, Janaina; Fonseca Sarmanho, Gabriel; Fortunato de Carvalho Rocha, Werickson; dos Reis, Lindomar Augusto

    2014-01-01

    The increase in renewable sources in the energy matrix of the countries is an effort to reduce dependency on crude oil and the environmental impacts associated with its use. In order to help overcome the lack of widely accepted quality standards for fuel ethanol and to guarantee its competitiveness in the international trade market, the NMIs have been working to develop certified reference materials for bio-fuels and measurement methods. Inorganic impurities such as Cu, Na and Fe may be present in the fuel ethanol and their presence is associated with corrosion and the formation of oxide deposits in some engine parts. The key comparison CCQM-K100 was carried out under the auspices of the Inorganic Analysis Working Group (IAWG) and the coordination of the National Institute of Metrology, Quality and Technology (INMETRO). The objective of this key comparison was to compare the measurement capabilities of the participants for the determination of Cu in fuel ethanol. Ten NMIs participated in this exercise and most of them used the isotopic dilution method for determining the amount of Cu. The median was chosen as key comparison reference value (KCRV). The assigned KCRV for the Cu content was 0.3589 µg/g with a combined standard uncertainty of 0.0014 µg/g. In general, there is a good agreement among the participants' results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Key comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael

    2015-01-01

    Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Activity measurements of the radionuclides 18F and 64Cu for the NIST, USA in the ongoing comparisons BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Nonis, M.; Bergeron, D.; Cessna, J.; Fitzgerald, R.; Pibida, L.; Zimmerman, B.; Fenwick, A.; Ferreira, K.; Keightley, J.; Da Silva, I.

    2017-01-01

    In 2016, comparisons of activity measurements of 18F and 64Cu using the Transfer Instrument of the International Reference System (SIRTI) took place at the National Institute of Standards and Technology (NIST, USA). This is the first SIRTI comparison for 64Cu. Ampoules containing about 27 kBq of 18F and 100 kBq of 64Cu solutions were measured in the SIRTI for about 5 and 1.5 half-lives, respectively. The NIST standardized the activity in the ampoules by ionization chamber measurements traceable to 4π(LS)β-γ anticoincidence measurements. The comparisons, identifiers BIPM.RI(II)-K4.F-18 and BIPM.RI(II)-K4.Cu-64, are linked to the corresponding BIPM.RI(II)-K1.F-18 and BIPM.RI(II)-K1.Cu-64 comparisons and degrees of equivalence with the respective key comparison reference values have been evaluated. The NIST replaces its earlier degree of equivalence for 18F obtained in the frame of the CCRI(II)-K3.F-18 comparison in 2001. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Evaluating intra- and inter- sample variability in Electron Spin Resonance dating of fossil teeth: an example from Cuesta de la Bajada site (Spain).

    NASA Astrophysics Data System (ADS)

    Duval, Mathieu; Grün, Rainer; Shao, Qingfeng; Martin, Loïc; Arnold, Lee J.

    2017-04-01

    Over the last decades, technological improvements have progressively enabled to significantly decrease the amount of material required for dating analyses. In particular, the combined use of laser ablation (LA) with ICP-MS opened new possibilities for high resolution in situ U-series analyses of fossil teeth. With this technique it is now possible to directly visualise the spatial distribution of U and Th isotopes in dental tissues. Moreover, the combination of LA-ICP-MS with Electron Spin Resonance (ESR) enables an increased sampling resolution, and offers the possibility to produce several ages for different areas within a given fossil tooth. To test the potential of this new approach, several fossil teeth were collected from the Middle Palaeolithic site of Cuesta de la Bajada (Teruel, Spain). Each tooth was divided into several subsamples, providing thus several combined US-ESR age results per tooth. For each subsample, ESR, high-resolution laser ablation and solution ICP-MS U-series analyses were systematically performed. Relative beta dose rate contributions from the different tissues and the sediment were also adjusted using DosiVox software and compared with those derived from the standard approach. The results of this work give some interesting insight into the intra- and inter- sample variability that may exist at a given site. The consistency of the final US-ESR age estimates obtained on teeth are also evaluated by comparison with the (semi)-independent results derived from ESR and Luminescence dating of optically bleached quartz grains collected from the same excavation area.

  13. Preparation of polyaniline/PbS core-shell nano/microcomposite and its application for photocatalytic H2 electrogeneration from H2O.

    PubMed

    Rabia, Mohamed; Mohamed, H S H; Shaban, Mohamed; Taha, S

    2018-01-18

    Lead sulfide (PbS) and polyaniline (PANI) nano/microparticles were prepared. Then, PANI/PbS core-shell nano/microcomposites (I, II, and III) were prepared by oxidative polymerization of different aniline concentrations (0.01, 0.03, and 0.05 M), respectively, in the presence of 0.05 M PbS. FT-IR, XRD, SEM, HR-TEM, and UV-Vis analyses were carried out to characterize the samples. From the FT-IR data, there are redshifts in PbS and PANI nano/microparticles bands in comparison with PANI/PbS nano/microcomposites. The average crystallite sizes of PANI/PbS core-shell nano/microcomposites (I, II, and III) from XRD analyses were 46.5, 55, and 42.16 nm, respectively. From the optical analyses, nano/microcomposite (II) has the optimum optical properties with two band gaps values of 1.41 and 2.79 eV. Then, the nano/microcomposite (II) membrane electrode supported on ITO glass was prepared and applied on the photoelectrochemical (PEC) H 2 generation from H 2 O. The characteristics current-voltage and current-time behaviors were measured at different wavelengths from 390 to 636 nm. Also, the incident photon-to-current conversion efficiency (IPCE) under monochromatic illumination condition was calculated. The optimum values for IPCE were 36.5 and 35.2% at 390 and 405 nm, respectively. Finally, a simple mechanism for PEC H 2 generation from H 2 O using the nano/microcomposite (II) membrane electrode was mentioned.

  14. The lifestyle of prokaryotic organisms influences the repertoire of promiscuous enzymes.

    PubMed

    Martínez-Núñez, Mario Alberto; Rodríguez-Vázquez, Katya; Pérez-Rueda, Ernesto

    2015-09-01

    The metabolism of microbial organisms and its diversity are partly the result of an adaptation process to the characteristics of the environments that they inhabit. In this work, we analyze the influence of lifestyle on the content of promiscuous enzymes in 761 nonredundant bacterial and archaeal genomes. Promiscuous enzymes were defined as those proteins whose catalytic activities are defined by two or more different Enzyme Commission (E.C.) numbers. The genomes analyzed were categorized into four lifestyles for their exhaustive comparisons: free-living, extremophiles, pathogens, and intracellular. From these analyses we found that free-living organisms have larger genomes and an enrichment of promiscuous enzymes. In contrast, intracellular organisms showed smaller genomes and the lesser proportion of promiscuous enzymes. On the basis of our data, we show that the proportion of promiscuous enzymes in an organism is mainly influenced by the lifestyle, where fluctuating environments promote its emergence. Finally, we evidenced that duplication processes occur preferentially in metabolism of free-living and extremophiles species. © 2015 Wiley Periodicals, Inc.

  15. [An analysis of cephalometric polygons in 21 sets of triplets].

    PubMed

    Kosovcević, Z; Marković, M

    1991-01-01

    Lateral cephalometric radiographs of 21 sets of triplets (4 monozygotic, 12 dizygotic and 5 three zygotic) were used for this study. The following two polygons were analysed: SNA and NSAr Go Me. Superimposition of the cephalometric tracings was made on the S-N line with S as the registration point. Intra- and inter-set comparisons between monozygotic (MZ), dizygotic (DZ) and three zygotic (TZ) triplets were made. Members of MZ triplets demonstrated the greatest similarity in size and form of the polygons. The second greatest similarity was found between MZ members of the DZ triplets, while the third DZ member of all such triplets showed much higher difference compared with the MZ members. Finally, triplets of TZ sets demonstrated the greatest difference between each other. The results obtained from this study indicated that genetic factors played a dominant role in growth and development of the craniofacial complex. However, difference found between members of MZ triplets suggested an importance of environmental factors in these processes as well.

  16. A general strategy toward the rational synthesis of metal tungstate nanostructures using plasma electrolytic oxidation method

    NASA Astrophysics Data System (ADS)

    Jiang, Yanan; Liu, Baodan; Zhai, Zhaofeng; Liu, Xiaoyuan; Yang, Bing; Liu, Lusheng; Jiang, Xin

    2015-11-01

    A new method based on conventional plasma electrolytic oxidation (PEO) technology has been developed for the rational synthesis of metal tungstate nanostructures. Using this method, ZnWO4 and NiWO4 nanostructures with controllable morphologies (nanorods, nanosheets and microsheets) and superior crystallinity have been synthesized. It has been found that the morphology diversity of ZnWO4 nanostructures can be selectively tailored through tuning the electrolyte concentration and annealing temperatures, showing obvious advantages in comparison to traditional hydrothermal and sol-gel methods. Precise microscopy analyses on the cross section of the PEO coating and ZnWO4 nanostructures confirmed that the precursors initially precipitated in the PEO coating and its surface during plasma discharge process are responsible for the nucleation and subsequent growth of metal tungstate nanostructures by thermal annealing. The method developed in this work represents a general strategy toward the rational synthesis of metal oxide nanostructures and the formation mechanism of metal tungstate nanostructures fabricated by the PEO method is finally discussed.

  17. Recent results and perspectives on cosmology and fundamental physics from microwave surveys

    NASA Astrophysics Data System (ADS)

    Burigana, Carlo; Battistelli, Elia Stefano; Benetti, Micol; Cabass, Giovanni; de Bernardis, Paolo; di Serego Alighieri, Sperello; di Valentino, Eleonora; Gerbino, Martina; Giusarma, Elena; Gruppuso, Alessandro; Liguori, Michele; Masi, Silvia; Norgaard-Nielsen, Hans Ulrik; Rosati, Piero; Salvati, Laura; Trombetti, Tiziana; Vielva, Patricio

    2016-04-01

    Recent cosmic microwave background (CMB) data in temperature and polarization have reached high precision in estimating all the parameters that describe the current so-called standard cosmological model. Recent results about the integrated Sachs-Wolfe (ISW) effect from CMB anisotropies, galaxy surveys, and their cross-correlations are presented. Looking at fine signatures in the CMB, such as the lack of power at low multipoles, the primordial power spectrum (PPS) and the bounds on non-Gaussianities, complemented by galaxy surveys, we discuss inflationary physics and the generation of primordial perturbations in the early universe. Three important topics in particle physics, the bounds on neutrinos masses and parameters, on thermal axion mass and on the neutron lifetime derived from cosmological data are reviewed, with attention to the comparison with laboratory experiment results. Recent results from cosmic polarization rotation (CPR) analyses aimed at testing the Einstein equivalence principle (EEP) are presented. Finally, we discuss the perspectives of next radio facilities for the improvement of the analysis of future CMB spectral distortion experiments.

  18. Organic acid modeling and model validation: Workshop summary. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, T.J.; Eilers, J.M.

    1992-08-14

    A workshop was held in Corvallis, Oregon on April 9--10, 1992 at the offices of E&S Environmental Chemistry, Inc. The purpose of this workshop was to initiate research efforts on the entitled ``Incorporation of an organic acid representation into MAGIC (Model of Acidification of Groundwater in Catchments) and testing of the revised model using Independent data sources.`` The workshop was attended by a team of internationally-recognized experts in the fields of surface water acid-bass chemistry, organic acids, and watershed modeling. The rationale for the proposed research is based on the recent comparison between MAGIC model hindcasts and paleolimnological inferences ofmore » historical acidification for a set of 33 statistically-selected Adirondack lakes. Agreement between diatom-inferred and MAGIC-hindcast lakewater chemistry in the earlier research had been less than satisfactory. Based on preliminary analyses, it was concluded that incorporation of a reasonable organic acid representation into the version of MAGIC used for hindcasting was the logical next step toward improving model agreement.« less

  19. A novel explicit equation for the friction factor prediction in the annular flow with drag-reducing polymer

    NASA Astrophysics Data System (ADS)

    Lakzian, Esmail; Masoudifar, Amir; Saghi, Hassan

    2017-03-01

    In this paper, a novel explicit equation is presented for the friction factor prediction in the annular flow with drag reducing polymer (DRP). By using dimensional analyses and curve fitting on the published experimental data, the suggested equation is derived based on the logarithmic velocity profiles and power law in boundary layers. In the next step, a least squares method is used to calibrate the presented equation. Then, the equation is used to friction factor prediction of the gas-liquid mixture with DRP and the results are compared with the experimental data and the Al-Sarkhi ones. Finally, drag reduction (DR) is applied as the ratio of the friction factor reduction using DRP to the friction factor without DRP. The DR results show that the suggested equation has a better agreement with the experimental data in comparison with the pervious equations. The results also show that DR prediction decreases with the increase of the gas superficial velocity.

  20. Development of the Basis for an Analytical Protocol for Feeds and Products of Bio-oil Hydrotreatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oasmaa, Anja; Kuoppala, Eeva; Elliott, Douglas C.

    2012-04-02

    Methods for easily following the main changes in the composition, stability, and acidity of bio-oil in hydrotreatment are presented. The correlation to more conventional methods is provided. Depending on the final use the upgrading requirement is different. This will create challenges also for the analytical protocol. Polar pyrolysis liquids and their products can be divided into five main groups with solvent fractionation the change in which is easy to follow. This method has over ten years been successfully used for comparison of fast pyrolysis bio-oil quality, and the changes during handling, and storage, provides the basis of the analytical protocolmore » presented in this paper. The method has most recently been used also for characterisation of bio-oil hydrotreatment products. Discussion on the use of gas chromatographic and spectroscopic methods is provided. In addition, fuel oil analyses suitable for fast pyrolysis bio-oils and hydrotreatment products are discussed.« less

  1. Written object naming, spelling to dictation, and immediate copying: Different tasks, different pathways?

    PubMed

    Bonin, Patrick; Méot, Alain; Lagarrigue, Aurélie; Roux, Sébastien

    2015-01-01

    We report an investigation of cross-task comparisons of handwritten latencies in written object naming, spelling to dictation, and immediate copying. In three separate sessions, adults had to write down a list of concrete nouns from their corresponding pictures (written naming), from their spoken (spelling to dictation) and from their visual presentation (immediate copying). Linear mixed models without random slopes were performed on the latencies in order to study and compare within-task fixed effects. By-participants random slopes were then included to investigate individual differences within and across tasks. Overall, the findings suggest that written naming, spelling to dictation, and copying all involve a lexical pathway, but that written naming relies on this pathway more than the other two tasks do. Only spelling to dictation strongly involves a nonlexical pathway. Finally, the analyses performed at the level of participants indicate that, depending on the type of task, the slower participants are more or less influenced by certain psycholinguistic variables.

  2. Reduced size dual band pass filters for RFID applications with excellent bandpass/bandstop characteristics

    NASA Astrophysics Data System (ADS)

    Abdalla, M. A.; Choudhary, D. Kumar; Chaudhary, R. Kumar

    2018-02-01

    This paper presents the design of two reduced size dual-band metamaterial bandpass filters and its simulation followed by measurements of proposed filters. These filters are supporting different frequency bands and primarily could be utilize in radio frequency identification (RFID) application. The filter includes three cells in which two are symmetrical and both inductively coupled with the third cell which is present in between them. In the proposed designs, three different metamaterial composite right/left handed (CRLH) cell resonators have been analysed for compactness. The CRLH cell consists of an interdigital capacitor, a stub/meander line/spiral inductor and a via to connect the top of the structure and ground plane. Finally, the proposed dual band bandpass filters (using meander line and spiral inductor) are showing size reduction by 65% and 50% (with 25% operating frequency reduction), respectively, in comparison with reference filter using stub inductor. More than 30 dB attenuation has been achieved between the two passbands.

  3. Proposal for a study of computer mapping of terrain using multispectral data from ERTS-A for the Yellowstone National Park test site

    NASA Technical Reports Server (NTRS)

    Smedes, H. W. (Principal Investigator); Root, R. R.; Roller, N. E. G.; Despain, D.

    1978-01-01

    The author has identified the following significant results. A terrain map of Yellowstone National Park showed plant community types and other classes of ground cover in what is basically a wild land. The map comprised 12 classes, six of which were mapped with accuracies of 70 to 95%. The remaining six classes had spectral reflectances that overlapped appreciably, and hence, those were mapped less accurately. Techniques were devised for quantitatively comparing the recognition map of the park with control data acquired from ground inspection and from analysis of sidelooking radar images, a thermal IR mosaic, and IR aerial photos of several scales. Quantitative analyses were made in ten 40 sq km test areas. Comparison mechanics were performed by computer with the final results displayed on line printer output. Forested areas were mapped by computer using ERTS data for less than 1/4 the cost of the conventional forest mapping technique for topographic base maps.

  4. Comparative study of tool machinery sliding systems; comparison between plane and cylindrical basic shapes

    NASA Astrophysics Data System (ADS)

    Glăvan, D. O.; Babanatsas, T.; Babanatis Merce, R. M.; Glăvan, A.

    2018-01-01

    The paper brings in attention the importance that the sliding system of a tool machinery is having in the final precision of the manufacturing. We are basically comparing two type of slides, one constructed with plane surfaces and the other one with circular cross-sections (as known as cylindrical slides), analysing each solution from the point of view of its technology of manufacturing, of the precision that the particular slides are transferring to the tool machinery, cost of production, etc. Special attention is given to demonstrate theoretical and to confirm by experimental works what is happening with the stress distribution in the case of plane slides and cylindrical slides, both in longitudinal and in cross-over sections. Considering the results obtained for the stress distribution in the transversal and longitudinal cross sections, by composing them, we can obtain the stress distribution on the semicircular slide. Based on the results, special solutions for establishing the stress distribution between two surfaces without interact in the contact zone have been developed.

  5. Patient safety in external beam radiotherapy, results of the ACCIRAD project: Recommendations for radiotherapy institutions and national authorities on assessing risks and analysing adverse error-events and near misses.

    PubMed

    Malicki, Julian; Bly, Ritva; Bulot, Mireille; Godet, Jean-Luc; Jahnen, Andreas; Krengli, Marco; Maingon, Philippe; Prieto Martin, Carlos; Skrobala, Agnieszka; Valero, Marc; Jarvinen, Hannu

    2018-05-02

    The ACCIRAD project, commissioned by the European Commission (EC) to develop guidelines for risk analysis of accidental and unintended exposures in external beam radiotherapy (EBRT), was completed in the year 2014. In 2015, the "General guidelines on risk management in external beam radiotherapy" were published as EC report Radiation Protection (RP)-181. The present document is the third and final report of the findings from the ACCIRAD project. The main aim of this paper is to describe the key features of the risk management process and to provide general guidelines for radiotherapy departments and national authorities on risk assessment and analysis of adverse error-events and near misses. The recommendations provided here and in EC report RP-181 are aimed at promoting the harmonisation of risk management systems across Europe, improving patient safety, and enabling more reliable inter-country comparisons. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Breastfeeding and maternal alcohol use: Prevalence and effects on child outcomes and fetal alcohol spectrum disorders.

    PubMed

    May, Philip A; Hasken, Julie M; Blankenship, Jason; Marais, Anna-Susan; Joubert, Belinda; Cloete, Marise; de Vries, Marlene M; Barnard, Ronel; Botha, Isobel; Roux, Sumien; Doms, Cate; Gossage, J Phillip; Kalberg, Wendy O; Buckley, David; Robinson, Luther K; Adnams, Colleen M; Manning, Melanie A; Parry, Charles D H; Hoyme, H Eugene; Tabachnick, Barbara; Seedat, Soraya

    2016-08-01

    Determine any effects that maternal alcohol consumption during the breastfeeding period has on child outcomes. Population-based samples of children with fetal alcohol spectrum disorders (FASD), normally-developing children, and their mothers were analyzed for differences in child outcomes. Ninety percent (90%) of mothers breastfed for an average of 19.9 months. Of mothers who drank postpartum and breastfed (MDPB), 47% breastfed for 12 months or more. In case control analyses, children of MDPB were significantly lighter, had lower verbal IQ scores, and more anomalies in comparisons controlling for prenatal alcohol exposure and final FASD diagnosis. Utilizing a stepwise logistic regression model adjusting for nine confounders of prenatal drinking and other maternal risks, MDPB were 6.4 times more likely to have a child with FASD than breastfeeding mothers who abstained from alcohol while breastfeeding. Alcohol use during the period of breastfeeding was found to significantly compromise a child's development. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. BREASTFEEDING AND MATERNAL ALCOHOL USE: PREVALENCE AND EFFECTS ON CHILD OUTCOMES AND FETAL ALCOHOL SPECTRUM DISORDERS

    PubMed Central

    May, Philip A.; Hasken, Julie M.; Blankenship, Jason; Marais, Anna-Susan; Joubert, Belinda; Cloete, Marise; de Vries, Marlene M.; Barnard, Ronel; Botha, Isobel; Roux, Sumien; Doms, Cate; Gossage, J. Phillip; Kalberg, Wendy O.; Buckley, David; Robinson, Luther K.; Adnams, Colleen M.; Manning, Melanie A.; Parry, Charles D.H.; Hoyme, H. Eugene; Tabachnick, Barbara; Seedat, Soraya

    2016-01-01

    Objective Determine any effects that maternal alcohol consumption during the breastfeeding period has on child outcomes. Methods Population-based samples of children with fetal alcohol spectrum disorders (FASD), normally-developing children, and their mothers were analyzed for differences in child outcomes. Results Ninety percent (90%) of mothers breastfed for an average of 19.9 months. Of mothers who drank postpartum and breastfed (MDPB), 47% breastfed for 12 months or more. In case control analyses, children of MDPB were significantly lighter, had lower verbal IQ scores, and more anomalies in comparisons controlling for prenatal alcohol exposure and final FASD diagnosis. Utilizing a stepwise logistic regression model adjusting for nine confounders of prenatal drinking and other maternal risks, MDPB were 6.4 times more likely to have a child with FASD than breastfeeding mothers who abstained from alcohol while breastfeeding. Conclusions Alcohol use during the period of breastfeeding was found to significantly compromise a child’s development. PMID:27174445

  8. Hypothalamic transcriptomes of 99 mouse strains reveal trans eQTL hotspots, splicing QTLs and novel non-coding genes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasin-Brumshtein, Yehudit; Khan, Arshad H.; Hormozdiari, Farhad

    2016-09-13

    Previous studies had shown that the integration of genome wide expression profiles, in metabolic tissues, with genetic and phenotypic variance, provided valuable insight into the underlying molecular mechanisms. We used RNA-Seq to characterize hypothalamic transcriptome in 99 inbred strains of mice from the Hybrid Mouse Diversity Panel (HMDP), a reference resource population for cardiovascular and metabolic traits. We report numerous novel transcripts supported by proteomic analyses, as well as novel non coding RNAs. High resolution genetic mapping of transcript levels in HMDP, reveals bothlocalandtransexpression Quantitative Trait Loci (eQTLs) demonstrating 2transeQTL 'hotspots' associated with expression of hundreds of genes. We alsomore » report thousands of alternative splicing events regulated by genetic variants. Finally, comparison with about 150 metabolic and cardiovascular traits revealed many highly significant associations. Our data provide a rich resource for understanding the many physiologic functions mediated by the hypothalamus and their genetic regulation.« less

  9. Automatic load forecasting. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, D.J.; Vemuri, S.

    A method which lends itself to on-line forecasting of hourly electric loads is presented and the results of its use are compared to models developed using the Box-Jenkins method. The method consists of processing the historical hourly loads with a sequential least-squares estimator to identify a finite order autoregressive model which in turn is used to obtain a parsimonious autoregressive-moving average model. A procedure is also defined for incorporating temperature as a variable to improve forecasts where loads are temperature dependent. The method presented has several advantages in comparison to the Box-Jenkins method including much less human intervention and improvedmore » model identification. The method has been tested using three-hourly data from the Lincoln Electric System, Lincoln, Nebraska. In the exhaustive analyses performed on this data base this method produced significantly better results than the Box-Jenkins method. The method also proved to be more robust in that greater confidence could be placed in the accuracy of models based upon the various measures available at the identification stage.« less

  10. What We Talk About When We Talk About Drought: Tree-ring Perspectives on Model-Data Comparisons in Hydroclimate Research

    NASA Astrophysics Data System (ADS)

    Cook, B.; Anchukaitis, K. J.

    2017-12-01

    Comparative analyses of paleoclimate reconstructions and climate model simulations can provide valuable insights into past and future climate events. Conducting meaningful and quantitative comparisons, however, can be difficult for a variety of reasons. Here, we use tree-ring based hydroclimate reconstructions to discuss some best practices for paleoclimate-model comparisons, highlighting recent studies that have successfully used this approach. These analyses have improved our understanding of the Medieval-era megadroughts, ocean forcing of large scale drought patterns, and even climate change contributions to future drought risk. Additional work is needed, however, to better reconcile and formalize uncertainties across observed, modeled, and reconstructed variables. In this regard, process based forward models of proxy-systems will likely be a critical tool moving forward.

  11. Update of the BIPM comparison BIPM.RI(II)-K1.Cu-64 of activity measurements of the radionuclide 64Cu to include the 2009 results of the CMI-IIR (Czech Rep.) and the NPL (UK), the 2010 result of the LNE-LNHB (France) and the 2011 result of the ENEA-INMRI (Italy)

    NASA Astrophysics Data System (ADS)

    Michotte, C.; Ratel, G.; Courte, S.; Sochorovà, J.; Auerbach, P.; Keightley, J.; Johansson, L.; Bakhshandeiar, E.; Cassette, P.; Moune, M.; Capogni, M.; De Felice, P.

    2013-01-01

    Since 2009, four national metrology institutes (NMI) have submitted four samples of known activity of 64Cu to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)-K1.Cu-64. The values of the activity submitted were between about 3 MBq and 260 MBq. There are now five results in the BIPM.RI(II)-K1.Cu-64 comparison. A key comparison reference value (KCRV) has been calculated for the first time for this nuclide. The degrees of equivalence between each equivalent activity measured in the SIR and the KCRV have been calculated and the results are given in the form of a table. A graphical presentation is also given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the VSL, Netherlands and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; de Prez, L. A.; Jansen, B. J.; Pooter, J. A.

    2017-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the Dutch Metrology Institute (VSL) and the Bureau International des Poids et Mesures (BIPM) from 23 September to 20 October 2014. The comparison was based on the determination of absorbed dose to water for three radiation qualities of the medical accelerator facilities of the National Physical Laboratory (United Kingdom). After establishing Draft B, the VSL discovered an error in the calculation of the correction factor for excess-heat linked to the VSL glass vessel used in the measurements at the NPL. The comparison results for the revised standard, reported as ratios of the VSL and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 0.9959 (54) at 6 MV, 0.9958 (64) at 10 MV and 0.9991 (75) at 25 MV. This result is part of the on-going BIPM.RI(I)-K6 series of comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Activity measurements of a suite of radionuclides (241Am, 239,240Pu, 238Pu, 238U, 234U, 235U, 232Th, 230Th, 228Th, 228Ra, 137Cs, 210Pb, 90Sr and 40K) in biota reference material (Ocean Shellfish): CCRI(II)-S3

    NASA Astrophysics Data System (ADS)

    Nour, S.; Karam, L. R.; Inn, K. G. W.

    2012-01-01

    In 2005, the CCRI decided that a comparison undertaken from 2002 to 2008 by the NIST (under the auspices of the Inter-America Metrology System [SIM]) in the development of a new biota (Ocean Shellfish) standard reference material (SRM) was sufficiently well constructed that it could be converted into a supplementary comparison under CCRI(II), with comparison identifier CCRI(II)-S3. This would enable the comparison to be used to support calibration and measurement capability (CMC) claims for radionuclide measurements in reference materials (specifically, animal-based organic materials). Previous comparisons of radionuclides have been of single or multiple nuclides in non-complex matrices and results of such could not be extended to support capabilities to measure the same nuclides in reference materials. The results of this comparison have been used to determine the certified reference value of the SRM. The key comparison working group (KCWG) of the CCRI(II) has approved this approach as a mechanism to link all the results to certified 'reference values' in lieu of the key comparison reference value (KCRV) of these specified radionuclides in this type of matrix (shellfish) so as to support CMCs of similar materials submitted by the present participants. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. MAAMD: a workflow to standardize meta-analyses and comparison of affymetrix microarray data

    PubMed Central

    2014-01-01

    Background Mandatory deposit of raw microarray data files for public access, prior to study publication, provides significant opportunities to conduct new bioinformatics analyses within and across multiple datasets. Analysis of raw microarray data files (e.g. Affymetrix CEL files) can be time consuming, complex, and requires fundamental computational and bioinformatics skills. The development of analytical workflows to automate these tasks simplifies the processing of, improves the efficiency of, and serves to standardize multiple and sequential analyses. Once installed, workflows facilitate the tedious steps required to run rapid intra- and inter-dataset comparisons. Results We developed a workflow to facilitate and standardize Meta-Analysis of Affymetrix Microarray Data analysis (MAAMD) in Kepler. Two freely available stand-alone software tools, R and AltAnalyze were embedded in MAAMD. The inputs of MAAMD are user-editable csv files, which contain sample information and parameters describing the locations of input files and required tools. MAAMD was tested by analyzing 4 different GEO datasets from mice and drosophila. MAAMD automates data downloading, data organization, data quality control assesment, differential gene expression analysis, clustering analysis, pathway visualization, gene-set enrichment analysis, and cross-species orthologous-gene comparisons. MAAMD was utilized to identify gene orthologues responding to hypoxia or hyperoxia in both mice and drosophila. The entire set of analyses for 4 datasets (34 total microarrays) finished in ~ one hour. Conclusions MAAMD saves time, minimizes the required computer skills, and offers a standardized procedure for users to analyze microarray datasets and make new intra- and inter-dataset comparisons. PMID:24621103

  15. Evaluation of the User Strategy on 2d and 3d City Maps Based on Novel Scanpath Comparison Method and Graph Visualization

    NASA Astrophysics Data System (ADS)

    Dolezalova, J.; Popelka, S.

    2016-06-01

    The paper is dealing with scanpath comparison of eye-tracking data recorded during case study focused on the evaluation of 2D and 3D city maps. The experiment contained screenshots from three map portals. Two types of maps were used - standard map and 3D visualization. Respondents' task was to find particular point symbol on the map as fast as possible. Scanpath comparison is one group of the eye-tracking data analyses methods used for revealing the strategy of the respondents. In cartographic studies, the most commonly used application for scanpath comparison is eyePatterns that output is hierarchical clustering and a tree graph representing the relationships between analysed sequences. During an analysis of the algorithm generating a tree graph, it was found that the outputs do not correspond to the reality. We proceeded to the creation of a new tool called ScanGraph. This tool uses visualization of cliques in simple graphs and is freely available at www.eyetracking.upol.cz/scangraph. Results of the study proved the functionality of the tool and its suitability for analyses of different strategies of map readers. Based on the results of the tool, similar scanpaths were selected, and groups of respondents with similar strategies were identified. With this knowledge, it is possible to analyse the relationship between belonging to the group with similar strategy and data gathered from the questionnaire (age, sex, cartographic knowledge, etc.) or type of stimuli (2D, 3D map).

  16. Final report for tank 241-AP-108, grab samples 8AP-96-1, 8AP-96-2 and 8AP-96-FB

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esch, R.A.

    1996-04-19

    This document is the final report deliverable for the tank 241-AP-108 grab samples. The samples were subsampled and analyzed in accordance with the TSAP. Included in this report are the results for the Waste Compatibility analyses, with the exception of DSC and thermogravimetric analysis (TGA) results which were presented in the 45 Day report (Part 2 of this document). The raw data for all analyses, with the exception of DSC and TGA, are also included in this report.

  17. Rotational flow in tapered slab rocket motors

    NASA Astrophysics Data System (ADS)

    Saad, Tony; Sams, Oliver C.; Majdalani, Joseph

    2006-10-01

    Internal flow modeling is a requisite for obtaining critical parameters in the design and fabrication of modern solid rocket motors. In this work, the analytical formulation of internal flows particular to motors with tapered sidewalls is pursued. The analysis employs the vorticity-streamfunction approach to treat this problem assuming steady, incompressible, inviscid, and nonreactive flow conditions. The resulting solution is rotational following the analyses presented by Culick for a cylindrical motor. In an extension to Culick's work, Clayton has recently managed to incorporate the effect of tapered walls. Here, an approach similar to that of Clayton is applied to a slab motor in which the chamber is modeled as a rectangular channel with tapered sidewalls. The solutions are shown to be reducible, at leading order, to Taylor's inviscid profile in a porous channel. The analysis also captures the generation of vorticity at the surface of the propellant and its transport along the streamlines. It is from the axial pressure gradient that the proper form of the vorticity is ascertained. Regular perturbations are then used to solve the vorticity equation that prescribes the mean flow motion. Subsequently, numerical simulations via a finite volume solver are carried out to gain further confidence in the analytical approximations. In illustrating the effects of the taper on flow conditions, comparisons of total pressure and velocity profiles in tapered and nontapered chambers are entertained. Finally, a comparison with the axisymmetric flow analog is presented.

  18. [The survivability of patients with cervical cancer of IIB stage].

    PubMed

    Kryzhanivs'ka, A Ie; Diakiv, I B

    2014-01-01

    To the present tense finally mine-out not tactic of treatment of patients with the cervical cancer (CC) of IIB stage, but in the standards of diagnostics and treatment there are different variants of treatment of this pathology, and choice, most optimum, as a rule, depends on subjective opinion of doctor. Consequently, purpose of our work--to promote efficiency of treatment of patients on CC IIB the stage, by application of neoadjuvant chemotherapy in the combined treatment. The results of treatment are analysed 291 patients on CC IIB stages which got radical treatment in Ivano-Frankivsk OKOD from 1998 to 2013 years. At the use of neoadjuvant chemotherapy index of general 5-years-survival and nonrecurrence survivability made 74.4% and 70.8%, and to preoperative chemotherapy--70.8% and 68.3% accordingly. At application of independent chemoradial therapy, to the index of general 5-years-survival and nonrecurrence survivability was 51.1% and 49.3%, accordingly. It is not exposed reliable difference (P < 0.05) at comparison of indexes of 5-years-survivability of patients which have got the combined methods of treatment, but a reliable difference is exposed when compared to patients which have got independent chemoradial therapy (P > 0.05). Consequently, application of the combined methods of treatment of patients of CC IIB stages were improved by indexes general 5-years and to nonrecurrence survivability by comparison to independent cheradial therapy. .

  19. Evaluation of key driver categories influencing sustainable waste management development with the analytic hierarchy process (AHP): Serbia example.

    PubMed

    Tot, Bojana; Srđević, Bojan; Vujić, Bogdana; Russo, Mário Augusto Tavares; Vujić, Goran

    2016-08-01

    The problems of waste management have become increasingly complex in recent decades. The increasing amount of generated waste, adopted legislation in the field of waste management, administrative issues, economic impacts and social awareness are important drivers in achieving a sustainable waste management system. However, in practice, there are many other drivers that are often mutually in conflict. The purpose of this research is to define the precise driver and their corresponding sub-drivers, which are relevant for developing a waste management system and, on the basis of their importance, to determine which has the predominant influence on the slow development of a waste management system at the national and regional level, within the Republic of Serbia and similar countries of southeast Europe. This research presents two levels of decision making: the first is a pair-wise comparison of the drivers in relation to the goal and the second is a pair-wise comparison of the sub-drivers in relation to the driver and in relation to the goal. Results of performed analyses on the waste management drivers were integrated via the decision-making process supported by an analytic hierarchy process (AHP). The final results of this research shows that the Institutional-Administrative driver is the most important for developing a sustainable waste management system. © The Author(s) 2016.

  20. Surveillance of Salmonella enteritidis in layer houses: a retrospective comparison of the Food and Drug Administration's egg safety rule (2010-2011) and the California Egg Quality Assurance Program (2007-2011).

    PubMed

    Pitesky, Maurice; Charlton, Bruce; Bland, Mark; Rolfe, Dan

    2013-03-01

    Between July 2007 and December 2011, 2660 environmental drag swab samples were collected in total from California layer flocks on behalf of the California Egg Quality Assurance Program (CEQAP), the egg safety rule (21 CFR Parts 16 and 118) of the Food and Drug Administration (FDA), or both. The samples were processed by the California Animal Health and Food Safety Lab, and positive or negative results for Salmonella enterica serovar Enteritidis (SE) were recorded. This study retrospectively compares the differences between the FDA and CEQAP programs with respect to their SE environmental sampling surveillance results. To accomplish this comparison, two different CEQAP (new and old) data sets representing different SE environmental surveillance approaches in the life of the flock were compared against each other and against the FDA's SE environmental testing plan. Significant differences were noted between the CEQAP and FDA programs with respect to the prevalence of SE in the farm environment. Analyses of the prevalence of SE at different stages in the flock's life cycle (chick papers, preproduction, midproduction, postmolt, and premarket) found the highest prevalence of SE in premarket (11.9%), followed by postmolt (3.5%) and midproduction (3.4%), and there was a tie between chick papers and preproduction (2.1%). To assess the main effects of the presence of SE in the farm environment, backwards binary logistic regression was used. Of six independent variables examined (age of flock, year, season, owner, CEQAP membership, and analysis of pooled samples vs. individual swabs), only age of flock, owner, and year were determined to be significant factors in the final model. Although CEQAP membership and pooling vs. individuals swabs were not included in the final model, Pearson chi-square tests did show significantly higher odds of SE for non-CEQAP member farms and higher odds of SE in pooled samples vs. individual swabs.

  1. [The changing spectrum of fever of unknown origin: trends and comparison with previous series at the Salvador Zubirán National Institute of Nutrition].

    PubMed

    Molina-Gamboa, J; Rivera-Morales, I; Camacho-Mezquita, E; Ponce-de-León, S

    1994-01-01

    We reviewed 400 medical records of patients admitted because of fever at the National Institute of Nutrition Salvador Zubirán between January 1, 1988 to December 31, 1992. Patient characteristics, diagnostic methods, final diagnosis and patient progress were analyzed, comparing these data with the previous series of the institute. We found 77 cases of fever of unknown origin (FUO), 47 males and 30 females, between 14 to 87 years of age. The final diagnosis encountered were: infections (40%), neoplasias (23%), collagen diseases (13%), and other diagnosis (8%). Sixteen percent of the cases remained without a final diagnosis. The most frequent infections were HIV infection (19%), tuberculosis (19%) and endocarditis (13%). The most common neoplasia was lymphoma (55.6%), with 90% of Hodgkin's disease. SLE was the most common autoimmune disease found. The methods to establish a final diagnosis were: biopsies (52%), serology (17%), cultures (12%), image (11%), and clinical (8%). Final diagnosis by serology tests increased from 2 to 17% in comparison with previous reports. Eight laparotomies were done, which is a less frequent practice than previously (10 vs 35%). We saw only one case of amebic hepatic abscess and had no cases of malaria and salmonellosis as final diagnosis of FUO; HIV infection was found to be a new major cause of FUO.

  2. 75 FR 32972 - Office of New Reactors: Notice of Availability of the Final Staff Guidance; Section 14.3.12 on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... the Final Staff Guidance; Section 14.3.12 on Physical Security Hardware Inspections, Tests, Analyses...: The NRC is issuing its Final Revision 1 to NUREG-0800, ``Standard Review Plan (SRP) for the Review of Safety Analysis Reports for Nuclear Power Plants,'' Section 14.3.12 on ``Physical Security Hardware...

  3. What is the strength of evidence for heart failure disease-management programs?

    PubMed

    Clark, Alexander M; Savard, Lori A; Thompson, David R

    2009-07-28

    Heart failure (HF) disease-management programs are increasingly common. However, some large and recent trials of programs have not reported positive findings. There have also been parallel recent advances in reporting standards and theory around complex nonpharmacological interventions. These developments compel reconsideration in this Viewpoint of how research into HF-management programs should be evaluated, the quality, specificity, and usefulness of this evidence, and the recommendations for future research. Addressing the main determinants of intervention effectiveness by using the PICO (Patient, Intervention, Comparison, and Outcome) approach and the recent CONSORT (Consolidated Standards of Reporting Trials) statement on nonpharmacological trials, we will argue that in both current trials and meta-analyses, interventions and comparisons are not sufficiently well described; that complex programs have been excessively oversimplified; and that potentially salient differences in programs, populations, and settings are not incorporated into analyses. In preference to more general meta-analyses of programs, adequate descriptions are first needed of populations, interventions, comparisons, and outcomes in past and future trials. This could be achieved via a systematic survey of study authors based on the CONSORT statement. These more detailed data on studies should be incorporated into future meta-analyses of comparable trials and used with other techniques such as patient-based outcomes data and meta-regression. Although trials and meta-analyses continue to have potential to generate useful evidence, a more specific evidence base is needed to support the development of effective programs for different populations and settings.

  4. Energy Conversion Advanced Heat Transport Loop and Power Cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, C. H.

    2006-08-01

    The Department of Energy and the Idaho National Laboratory are developing a Next Generation Nuclear Plant (NGNP) to serve as a demonstration of state-of-the-art nuclear technology. The purpose of the demonstration is two fold 1) efficient low cost energy generation and 2) hydrogen production. Although a next generation plant could be developed as a single-purpose facility, early designs are expected to be dual-purpose. While hydrogen production and advanced energy cycles are still in its early stages of development, research towards coupling a high temperature reactor, electrical generation and hydrogen production is under way. Many aspects of the NGNP must bemore » researched and developed in order to make recommendations on the final design of the plant. Parameters such as working conditions, cycle components, working fluids, and power conversion unit configurations must be understood. Three configurations of the power conversion unit were demonstrated in this study. A three-shaft design with 3 turbines and 4 compressors, a combined cycle with a Brayton top cycle and a Rankine bottoming cycle, and a reheated cycle with 3 stages of reheat were investigated. An intermediate heat transport loop for transporting process heat to a High Temperature Steam Electrolysis (HTSE) hydrogen production plant was used. Helium, CO2, and an 80% nitrogen, 20% helium mixture (by weight) were studied to determine the best working fluid in terms cycle efficiency and development cost. In each of these configurations the relative component size were estimated for the different working fluids. The relative size of the turbomachinery was measured by comparing the power input/output of the component. For heat exchangers the volume was computed and compared. Parametric studies away from the baseline values of the three-shaft and combined cycles were performed to determine the effect of varying conditions in the cycle. This gives some insight into the sensitivity of these cycles to various operating conditions as well as trade offs between efficiency and capital cost. Prametric studies were carried out on reactor outlet temperature, mass flow, pressure, and turbine cooling. Recommendations on the optimal working fluid for each configuration were made. A steady state model comparison was made with a Closed Brayton Cycle (CBC) power conversion system developed at Sandia National Laboratory (SNL). A preliminary model of the CBC was developed in HYSYS for comparison. Temperature and pressure ratio curves for the Capstone turbine and compressor developed at SNL were implemented into the HYSYS model. A comparison between the HYSYS model and SNL loop demonstrated power output predicted by HYSYS was much larger than that in the experiment. This was due to a lack of a model for the electrical alternator which was used to measure the power from the SNL loop. Further comparisons of the HYSYS model and the CBC data are recommended. Engineering analyses were performed for several configurations of the intermediate heat transport loop that transfers heat from the nuclear reactor to the hydrogen production plant. The analyses evaluated parallel and concentric piping arrangements and two different working fluids, including helium and a liquid salt. The thermal-hydraulic analyses determined the size and insulation requirements for the hot and cold leg pipes in the different configurations. Economic analyses were performed to estimate the cost of the va« less

  5. SPARC Intercomparison of Middle Atmosphere Climatologies

    NASA Technical Reports Server (NTRS)

    Randel, William; Fleming, Eric; Geller, Marvin; Hamilton, Kevin; Karoly, David; Ortland, Dave; Pawson, Steve; Swinbank, Richard; Udelhofen, Petra

    2002-01-01

    This atlas presents detailed incomparisons of several climatological wind and temperature data sets which cover the middle atmosphere (over altitudes approx. 10-80 km). A number of middle atmosphere climatologies have been developed in the research community based on a variety of meteorological analyses and satellite data sets. Here we present comparisons between these climatological data sets for a number of basic circulation statistics, such as zonal mean temperature, winds and eddy flux statistics. Special attention is focused on tropical winds and temperatures, where large differences exist among separate analyses. We also include comparisons between the global climatologies and historical rocketsonde wind and temperature measurements, and also with more recent lidar temperature data. These comparisons highlight differences and uncertainties in contemporary middle atmosphere data sets, and allow biases in particular analyses to be isolated. In addition, a brief atlas of zonal mean temperature and wind statistics is provided to highlight data availability and as a quick-look reference. This technical report is intended as a companion to the climatological data sets held in archive at the SPARC Data Center (http://www.sparc.sunysb.edu).

  6. A HIV-1 heterosexual transmission chain in Guangzhou, China: a molecular epidemiological study.

    PubMed

    Han, Zhigang; Leung, Tommy W C; Zhao, Jinkou; Wang, Ming; Fan, Lirui; Li, Kai; Pang, Xinli; Liang, Zhenbo; Lim, Wilina W L; Xu, Huifang

    2009-09-25

    We conducted molecular analyses to confirm four clustering HIV-1 infections (Patient A, B, C & D) in Guangzhou, China. These cases were identified by epidemiological investigation and suspected to acquire the infection through a common heterosexual transmission chain. Env C2V3V4 region, gag p17/p24 junction and partial pol gene of HIV-1 genome from serum specimens of these infected cases were amplified by reverse transcription polymerase chain reaction (RT-PCR) and nucleotide sequenced. Phylogenetic analyses indicated that their viral nucleotide sequences were significantly clustered together (bootstrap value is 99%, 98% and 100% in env, gag and pol tree respectively). Evolutionary distance analysis indicated that their genetic diversities of env, gag and pol genes were significantly lower than non-clustered controls, as measured by unpaired t-test (env gene comparison: p < 0.005; gag gene comparison: p < 0.005; pol gene comparison: p < 0.005). Epidemiological results and molecular analyses consistently illustrated these four cases represented a transmission chain which dispersed in the locality through heterosexual contact involving commercial sex worker.

  7. New volatile selenium and tellurium species in fermentation gases produced by composting duck manure

    NASA Astrophysics Data System (ADS)

    Pinel-Raffaitin, P.; Pécheyran, C.; Amouroux, D.

    The occurrence of volatile metal(loid) compounds is investigated in gases released from a compost composed of pine shavings, duck feathers and duck excreta. The fermentation gases were sampled using Tedlar bags, pre-concentrated with cryogenic trap and finally analysed by cryo-trapping followed by gas chromatography hyphenated to inductively coupled mass spectrometry (CT-GC-ICPMS). In addition to arsenic (As), bismuth (Bi), lead (Pb), antimony (Sb) and tin (Sn) volatile species, up to eight selenium (Se) and seven tellurium (Te) species, namely methylated, ethylated and mixed methyl-ethylated ones, are detected for the first time. Although few volatile species standards are available, their identification or semi-identification is established by using quantitative structure-activity relationship (QSAR) through the correlation between boiling point and retention time of each compound. Their semi-quantification highlights maximal concentrations ranging from 30 to 2300 ng m -3 for Se species and from 10 to 500 ng m -3 for Te species. The variations of their concentrations are examined by emphasizing the influences of both compost nature and compost maturation stage. Finally, the results obtained in this study outline the diversity and the quantity of Se and Te species especially in comparison with other fermentation gases. Their release could thus induce "olfactory pollution" and potential sanitary and environmental impacts if no effluent treatment is applied during the compost production.

  8. Physicochemical properties of calcium silicate-based formulations MTA Repair HP and MTA Vitalcem.

    PubMed

    Guimarães, Bruno Martini; Prati, Carlo; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Gandolfi, Maria Giovanna

    2018-04-05

    This study aimed to analyze the following physicochemical properties: radiopacity, final setting time, calcium release, pH change, solubility, water sorption, porosity, surface morphology, and apatite-forming ability of two calcium silicate-based materials. We tested MTA Repair HP and MTA Vitalcem in comparison with conventional MTA, analyzing radiopacity and final setting time. Water absorption, interconnected pores and apparent porosity were measured after 24-h immersion in deionized water at 37°C. Calcium and pH were tested up to 28 d in deionized water. We analyzed data using two-way ANOVA with Student-Newman-Keuls tests (p<0.05). We performed morphological and chemical analyses of the material surfaces using ESEM/EDX after 28 d in HBSS. MTA Repair HP showed similar radiopacity to that of conventional MTA. All materials showed a marked alkalinizing activity within 3 h, which continued for 28 d. MTA Repair HP showed the highest calcium release at 28 d (p<0.05). MTA Vitalcem showed statistically higher water sorption and solubility values (p<0.05). All materials showed the ability to nucleate calcium phosphate on their surface after 28 d in HBSS. MTA Repair HP and MTA Vitalcem had extended alkalinizing activity and calcium release that favored calcium phosphate nucleation. The presence of the plasticizer in MTA HP might increase its solubility and porosity. The radiopacifier calcium tungstate can be used to replace bismuth oxide.

  9. SUPPLEMENTARY COMPARISON: EUROMET.L-S10 Comparison of squareness measurements

    NASA Astrophysics Data System (ADS)

    Mokros, Jiri

    2005-01-01

    The idea of performing a comparison of squareness resulted from the need to review the MRA Appendix C, Category 90° square. At its meeting in October 1999 (in Prague) it was decided upon a first comparison of squareness measurements in the framework of EUROMET, numbered #570, starting in 2000, with the Slovak Institute of Metrology (SMU) as the pilot laboratory. During the preparation stage of the project, it was agreed that it should be submitted as a EUROMET supplementary comparison in the framework of the Mutual Recognition Arrangement (MRA) of the Metre Convention and would boost confidence in calibration and measurement certificates issued by the participating national metrology institutes. The aim of the comparison of squareness measurement was to compare and verify the declared calibration measurement capabilities of participating laboratories and to investigate the effect of systematic influences in the measurement process and their elimination. Eleven NMIs from the EUROMET region carried out this project. Two standards were calibrated: granite squareness standard of rectangular shape, cylindrical squareness standard of steel with marked positions for the profile lines. The following parameters had to be calibrated: granite squareness standard: interior angle γB between two lines AB and AC (envelope - LS regression) fitted through the measured profiles, and/or granite squareness standard: interior angle γLS between two LS regression lines AB and AC fitted through the measured profiles, cylindrical squareness standard: interior angles γ0°, γ90°, γ180°, γ270° between the LS regression line fitted through the measurement profiles at 0°, 90°, 180°, 270° and the envelope plane of the basis (resting on a surface plate), local LS straightness deviation for all measured profiles (2 and 4) of both standards. The results of the comparison are the deviations of profiles and angles measured by the individual NMIs from the reference values. These resulted from the weighted mean of data from participating laboratories, while some of them were excluded on the basis of statistical evaluation. Graphical interpretations of all deviations are contained in the Final Report. In order to compare the individual deviations mutually (25 profiles for the granite square and 44 profiles for the cylinder), graphical illustrations of 'standard deviations' and both extreme values (max. and min.) of deviations were created. This regional supplementary comparison has provided independent information about the metrological properties of the measuring equipment and method used by the participating NMIs. The Final Report does not contain the En values. Participants could not estimate some contributions in the uncertainty budget on the basis of previous comparisons, since no comparison of this kind had ever been organized. Therefore the En value cannot reflect the actual state of the given NMI. Instead of En, an analysis has been performed by means of the Grubbs test according to ISO 5725-2. This comparison provided information about the state of provision of metrological services in the field of big squares measurement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EUROMET, according to the provisions of the Mutual Recognition Arrangement (MRA).

  10. Training apartment upkeep skills to rehabilitation clients: a comparison of task analytic strategies.

    PubMed Central

    Williams, G E; Cuvo, A J

    1986-01-01

    The research was designed to validate procedures to teach apartment upkeep skills to severely handicapped clients with various categorical disabilities. Methodological features of this research included performance comparisons between general and specific task analyses, effect of an impasse correction baseline procedure, social validation of training goals, natural environment assessments and contingencies, as well as long-term follow-up. Subjects were taught to perform upkeep responses on their air conditioner-heating unit, electric range, refrigerator, and electrical appliances within the context of a multiple-probe across subjects experimental design. The results showed acquisition, long-term maintenance, and generalization of the upkeep skills to a nontraining apartment. General task analyses were recommended for assessment and specific task analyses for training. The impasse correction procedure generally did not produce acquisition. PMID:3710947

  11. Children's body image and social comparisons with peers and the media.

    PubMed

    Tatangelo, Gemma L; Ricciardelli, Lina A

    2017-05-01

    Social comparisons are related to the development of body dissatisfaction among adolescents and adults, yet this relationship remains relatively unexamined among children. This study examines children's peer and media-related social comparisons, and how this impacts on their body image. Children aged 8-10 years completed interviews (17 girls and 19 boys in individual interviews, and 16 girls and 16 boys in focus groups). Analyses revealed that appearance-related comparisons were more common among girls, whereas sports/ability-related comparisons were more common for boys. In addition, boys viewed media comparisons as inspiring, whereas girls reported negative emotions. Implications for future research and prevention programmes are discussed.

  12. A Meta-Meta-Analysis: Empirical Review of Statistical Power, Type I Error Rates, Effect Sizes, and Model Selection of Meta-Analyses Published in Psychology

    ERIC Educational Resources Information Center

    Cafri, Guy; Kromrey, Jeffrey D.; Brannick, Michael T.

    2010-01-01

    This article uses meta-analyses published in "Psychological Bulletin" from 1995 to 2005 to describe meta-analyses in psychology, including examination of statistical power, Type I errors resulting from multiple comparisons, and model choice. Retrospective power estimates indicated that univariate categorical and continuous moderators, individual…

  13. Atmospheric air pollutants: CO in Nitrogen, 5 μmol/mol

    NASA Astrophysics Data System (ADS)

    Konopelko, L. A.; Pankratov, V. V.; Pankov, A. A.; Ivahnenko, B. V.; Efremova, O. V.; Bakovec, N. V.; Mironchik, A. M.; Aleksandrov, V. V.

    2017-01-01

    This article presents the report on the COOMET supplementary comparison "Atmospheric air pollutants: CO in Nitrogen, 5 μmol/mol". Carbon monoxide (CO) is present in atmosphere due to different natural and anthropogenic sources. CO is a toxic gas and in concentrations higher than (3-5) μmol/mol it is hazardous to human health. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Mass: 100 mg, 10 g, 100 g, 1 kg, 10 kg and 50 kg

    NASA Astrophysics Data System (ADS)

    Kaçmaz, Sevda; Davidson, Stuart

    2017-01-01

    Bilateral mass comparison of mass standards of 100 mg, 2 g, 20 g, 500 g and 10 kg was carried out in 2011 to 2012 between UME and NPL. UME was the pilot laboratory. For all mass standards, the results show adequate agreement between the laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Final report of CCQM-K130 nitrogen mass fraction measurements in glycine

    NASA Astrophysics Data System (ADS)

    Medvedevskikh, Maria; Krasheninina, Maria; do Rego, Eliane C. P.; Wollinger, Wagner; Monteiro, Tânia M.; de Carvalho, Lucas J.; Acco Garcia, Steve Ali; Haraldsson, Conny; Rodriguez, M. Alejandra; Rodriguez, Gabriela; Salvo, Karino; Gavrilkin, Vladimir; Kulyk, Sergij; Samuel, Laly

    2017-01-01

    CCQM key comparison K-130 in the field of nitrogen mass fracton has been performed by the Inorganic Analysis Working Group (IAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this key comparison CCQM-K130 is to support National Measurement Institutes (NMIs) and Designated Institutes (DIs) to demonstrate the validity of the procedures the employed for determination of nitrogen mass fraction in glycine. Mass fraction of nitrogen is very important pointer because the results of these measurements are often used for determination of protein mass fraction that is an important indicator of the quality of the vast majority of food products and raw materials, in particular dry milk powder. Proteins-enzymes catalyze chemical reactions, protein along with fats and carbohydrates is one of the indicators characterizing the energy value of food, so its definition is mandatory for all food products. The study material for this key comparison has been selected to be representative as one of the aminoacid - the simplest part of the protein. Glycine is an amino acid, single acid that does not have any isomers (melting point -290 °C specific heat of evaporation - 528,6 J/kg; specific melting heat - 981,1 J/kg; pKa - 2, 34, molar mass - 75,07 g/mol, density - 1,607 g/cm3). Ural Scientific Research Institute for Metrology (UNIIM) acted as the coordinating laboratory of this comparison. Nine NMIs participated in this key comparison and one NMI participated in Pilot study that was condacted in parallel. Report A contains the results of key comparison and pilot study. The results of Pilot study were excluded from the Report B Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Final report on the torque key komparison CCM.T-K1.2 measurand torque: 0 N.m, 500 N.m, 1000 N.m

    NASA Astrophysics Data System (ADS)

    Röske, Dirk

    2015-01-01

    The purpose of the CIPM subsequent bilateral comparison CCM.T-K1.2 was to link another participant, namely the National Institute of Metrology (Thailand), in short NIMT, to the CCM.T-K1 torque key comparison. The measuring capabilities up to 1000 N.m of dead-weight torque standard machines with supported lever were investigated. The pilot laboratory was the same in both comparisons—it was the Physikalisch-Technische Bundesanstalt (PTB, Braunschweig, Germany). The same two very stable torque transducers with well-known properties were used as travelling standards. The measurements at the participating laboratory were carried out between November 2007 and February 2008. According to the technical protocol, torque steps of 500 N.m and 1000 N.m had to be measured both in clockwise and anticlockwise directions. Corrections had to be applied to the results reported by the participants taking into account the use of different amplifiers, the creep (due to different loading times of the machines) and the environmental conditions in the laboratories (temperature and relative humidity of the ambient air). The results of the pilot laboratory in this bilateral comparison are in very good agreement with the same results obtained in the CCM.T-K1 comparison. For each of the transducers, the two torque steps and both senses of direction of the torque vector, the key comparison reference value of the CCM.T-K1 was taken, and the results of participant NIMT were calculated with respect to these values. The agreement between the results is very good. The smallest expanded (k = 2) relative uncertainty of the machine stated by the participant is 1 × 10-4. The results of the comparison support this uncertainty statement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Comparison of density determination of liquid samples by density meters

    NASA Astrophysics Data System (ADS)

    Buchner, C.; Wolf, H.; Vámossy, C.; Lorefice, S.; Lenard, E.; Spohr, I.; Mares, G.; Perkin, M.; Parlic-Risovic, T.; Grue, L.-L.; Tammik, K.; van Andel, I.; Zelenka, Z.

    2016-01-01

    Hydrostatic density determinations of liquids as reference material are mainly performed by National Metrology Institutes to provide means for calibrating or checking liquid density measuring instruments such as oscillation-type density meters. These density meters are used by most of the metrology institutes for their calibration and scientific work. The aim of this project was to compare the results of the liquid density determination by oscillating density meters of the participating laboratories. The results were linked to CCM.D.K-2 partly via Project EURAMET.M.D.K-2 (1019) "Comparison of liquid density standards" by hydrostatic weighing piloted by BEV in 2008. In this comparison pentadecane, water and of oil with a high viscosity were measured at atmospheric pressure using oscillation type density meter. The temperature range was from 15 °C to 40 °C. The measurement results were in some cases discrepant. Further studies, comparisons are essential to explore the capability and uncertainty of the density meters Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. EURAMET.M.P-S9 / EURAMET 1170, LOOP2. Comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Otal, P.; Boineau, F.; Medina, N.; Pražák, D.; Wüthrich, C.; Saxholm, S.; Sabuga, W.; Kocas, I.; Durgut, Y.

    2017-01-01

    This report gives the results of a comparison of pressure standards of seven European National Metrology institutes in the range of negative gauge pressure from -950 hPa to 0 hPa. This comparison was piloted by LNE and was carried out from January 2011 to March 2012. This work is a part of the EURAMET project 1170 and is registered as a supplementary comparison EURAMET.M.P-S9. The transfer standard used was a pressure monitor RPM4 A160Ks manufactured by DH Instruments Inc., with a resolution of 0.1 Pa. The reference values have been determined from the weighted mean of the deviations reported by the participants for each specified pressure. Seventy-three of the seventy-seven values (96%) reported by the laboratories agree with the reference values within the expanded uncertainties with a coverage factor k = 2. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Final report on VMI-NMISA bilateral comparison APMP.T-K3.1: Realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

    NASA Astrophysics Data System (ADS)

    Liedberg, Hans

    2012-01-01

    The Comité Consulatif de Thermométrie (CCT) has organized several key comparisons to compare realizations of the ITS-90 in different National Metrology Institutes. To keep the organization, time scale and data processing of such a comparison manageable, the number of participants in a CCT key comparison (CCT KC) is limited to a few laboratories in each major economic region. Subsequent regional key comparisons are linked to the applicable CCT KC by two or more linking laboratories. For the temperature range from 83.8058 K (triple point of Ar) to 933.473 K (freezing point of Al), a key comparison, CCT-K3, was carried out from 1997 to 2001 among representative laboratories in North America, Europe and Asia. Following CCT-K3, the Asia-Pacific Metrology Program Key Comparison 3 (APMP.T-K3) was organized for National Metrology Institutes in the Asia/Pacific region. NMIA (Australia) and KRISS (South Korea) provided the link between CCT-K3 and APMP.T-K3. APMP.T-K3, which took place from February 2000 to June 2003, covered the temperature range from -38.8344 °C (triple point of Hg) to 419.527 °C (freezing point of Zn), using a standard platinum resistance thermometer (SPRT) as the artefact. In June 2007 the Vietnam Metrology Institute (VMI) requested a bilateral comparison to link their SPRT calibration capabilities to APMP.T-K3, and in October 2007 the National Metrology Institute of South Africa (NMISA) agreed to provide the link to APMP.T-K3. Like APMP.T-K3, the comparison was restricted to the Hg to Zn temperature range to reduce the chance of drift in the SPRT artefact. The comparison was carried out in a participant-pilot-participant topology (with NMISA as the pilot and VMI as the participant). VMI's results in the comparison were linked to the Average Reference Values of CCT-K3 via NMISA's results in APMP.T-K3. The resistance ratios measured by VMI and NMISA at Zn, Sn, Ga and Hg fixed points agree within their combined uncertainties, and VMI's results also agree with the CCT-K3 reference values at these fixed points. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Supplement to CCM.D-K4 'Hydrometer' report: linkage of EURAMET.M.D-K4 comparison, SIM.M.D-K4 comparison and the supplementary SIM.M.D-S2 to CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.

    2017-01-01

    Evaluation of different types of comparisons to a common set of reference values of a CIPM key comparison is essential to satisfy the concept of the CIPM Mutual Recognition Arrangement (CIPM MRA), where the DoEs of any participant who took part in comparisons should be within the Calibration and Measurement Capability (CMC) section of the CIPM MRA Key Comparison Data Base. The subject of this supplementary report is therefore to present the equivalence of each National Metrological Institute (NMI) participant in the CCM.D-K4 'Hydrometer' key comparison, which was performed in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20 °C, and the linkage of the European and Inter-American NMI results performed in the RMO.M.D-K4 comparisons as well as those of the supplementary SIM.M.D-S2 to the common set of KCRVs of the CCM.D-K4 'Hydrometer'. The linking procedure has been obtained by numerical simulation, based on the Monte Carlo method, in which the differences in the results of the different comparison between the intended laboratory and one or more linking laboratory/ies, which took part in both comparisons, are correlated with a continuous function describing the DoEs of the linking laboratory/ies with respect to the common set of KCRVs of the CCM.D-K4. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Report of the key comparison APMP.QM-K19. APMP comparison on pH measurement of borate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Asakai, Toshiaki; Maksimov, Igor; Suzuki, Toshihiro; Miura, Tsutomu; Obromsook, Krairerk; Tangpaisarnkul, Nongluck; Rodruangthum, Patumporn; Wong, Siu-Kay; Lam, Wai-Hing; Zakaria, Osman; Anuar Mohd. Amin, Khirul; Thanh, Ngo Huy; Máriássy, Michal; Vyskocil, Leos; Hankova, Zuzana; Fisicaro, Paola; Stoica, Daniela; Singh, Nahar; Soni, Daya; Ticona Canaza, Galia; Kutovoy, Viatcheslav; Barbieri Gonzaga, Fabiano; Dias, Júlio Cesar; Vospelova, Alena; Bakovets, Nickolay; Zhanasbayeva, Bibinur

    2015-01-01

    The APMP.QM-K19 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a borate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan (NMIJ) and the National Institute of Metrology (Thailand) (NIMT) at the APMP-TCQM meeting held 26-27 November 2012. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K19 and CCQM-K19.1. The comparison material was a borate buffer of pH around 9.2 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the second APMP key comparison on pH measurement and the fourth APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004, APMP.QM-P09 (a phthalate buffer) in 2006 and APMP.QM-K9/APMP.QM-P16 (a phosphate buffer) in 2010-2011. The results can be used further by any participant to support its CMC claim at least for a borate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the used temperature(s) or the full temperature range between 15°C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. related: an R package for analysing pairwise relatedness from codominant molecular markers.

    PubMed

    Pew, Jack; Muir, Paul H; Wang, Jinliang; Frasier, Timothy R

    2015-05-01

    Analyses of pairwise relatedness represent a key component to addressing many topics in biology. However, such analyses have been limited because most available programs provide a means to estimate relatedness based on only a single estimator, making comparison across estimators difficult. Second, all programs to date have been platform specific, working only on a specific operating system. This has the undesirable outcome of making choice of relatedness estimator limited by operating system preference, rather than being based on scientific rationale. Here, we present a new R package, called related, that can calculate relatedness based on seven estimators, can account for genotyping errors, missing data and inbreeding, and can estimate 95% confidence intervals. Moreover, simulation functions are provided that allow for easy comparison of the performance of different estimators and for analyses of how much resolution to expect from a given data set. Because this package works in R, it is platform independent. Combined, this functionality should allow for more appropriate analyses and interpretation of pairwise relatedness and will also allow for the integration of relatedness data into larger R workflows. © 2014 John Wiley & Sons Ltd.

  3. 1979-80 Internal Revenue Service Comparison Study. Final Report.

    ERIC Educational Resources Information Center

    Applied Management Sciences, Inc., Silver Spring, MD.

    Application forms for the Basic Educational Opportunity Grant (BEOG) program for 1979-1980 were compared to 1978 tax forms filed with the Internal Revenue Service (IRS). Comparisons were also made to data from similar 1974-1975 and 1976-1977 studies. Based on a sample of 407,596 applicants, findings include the following: between 1976-1977 and…

  4. A Technical, User and Cost Comparison Study of Microfiche Duplicate Film Material. Final Report.

    ERIC Educational Resources Information Center

    Prevel, James J.

    A technical, user and cost comparison study was undertaken to provide the Educational Resources Information Clearinghouse (ERIC) staff with data on silver halide, diazo, and vesicular type films for microfiche duplication. This information will allow ERIC to determine if diazo and/or vesicular films should be considered in producing ERIC duplicate…

  5. a Critical Review of Automated Photogrammetric Processing of Large Datasets

    NASA Astrophysics Data System (ADS)

    Remondino, F.; Nocerino, E.; Toschi, I.; Menna, F.

    2017-08-01

    The paper reports some comparisons between commercial software able to automatically process image datasets for 3D reconstruction purposes. The main aspects investigated in the work are the capability to correctly orient large sets of image of complex environments, the metric quality of the results, replicability and redundancy. Different datasets are employed, each one featuring a diverse number of images, GSDs at cm and mm resolutions, and ground truth information to perform statistical analyses of the 3D results. A summary of (photogrammetric) terms is also provided, in order to provide rigorous terms of reference for comparisons and critical analyses.

  6. Weapon Simulator Test Methodology Investigation: Comparison of Live Fire and Weapon Simulator Test Methodologies and the Effects of Clothing and Individual Equipment on Marksmanship

    DTIC Science & Technology

    2016-09-15

    METHODOLOGY INVESTIGATION: COMPARISON OF LIVE FIRE AND WEAPON SIMULATOR TEST METHODOLOGIES AND THE EFFECTS OF CLOTHING AND INDIVIDUAL EQUIPMENT ON...2. REPORT TYPE Final 3. DATES COVERED (From - To) October 2014 – August 2015 4. TITLE AND SUBTITLE WEAPON SIMULATOR TEST METHODOLOGY INVESTIGATION...COMPARISON OF LIVE FIRE AND WEAPON SIMULATOR TEST METHODOLOGIES AND THE EFFECTS OF CLOTHING AND INDIVIDUAL EQUIPMENT ON MARKSMANSHIP 5a. CONTRACT

  7. A comparison of self-oscillating phonation models

    NASA Astrophysics Data System (ADS)

    McPhail, Michael; Campo, Elizabeth; Walters, Gage; Krane, Michael

    2017-11-01

    This talk presents a comparison of self-oscillating models of phonation. The goal is to assess how well synthetic rubber vocal folds reproduce the gross behavior of phonation. Data from molded rubber folds and a variety of excised mammalian larynges were collected from the literature and from the authors' physical model. Gross trends are discussed and a simple scaling is presented that appears to collapse these data. Finally, comparisons between molded rubber folds and excised larynges are highlighted. Acknowledge support from NIH DC R01005642-11.

  8. Alienation and Achievement Among Oglala Sioux Secondary School Students. Final Report.

    ERIC Educational Resources Information Center

    Spilka, Bernard

    As a final report on alienation and achievement among 753 Oglala Sioux secondary school students on the Pine Ridge Reservation, this document attempts to portray the circumstances affecting the Indian child in school. To provide a basis for comparison, the sample also contained 855 white secondary school pupils. General findings which are believed…

  9. Agreement and Coverage of Indicators of Response to Intervention: A Multimethod Comparison and Simulation

    ERIC Educational Resources Information Center

    Fletcher, Jack M.; Stuebing, Karla K.; Barth, Amy E.; Miciak, Jeremy; Francis, David J.; Denton, Carolyn

    2014-01-01

    Purpose: Agreement across methods for identifying students as inadequate responders or as learning disabled is often poor. We report (1) an empirical examination of final status (postintervention benchmarks) and dual-discrepancy growth methods based on growth during the intervention and final status for assessing response to intervention and (2) a…

  10. A Constraint-Based Approach to Acquisition of Word-Final Consonant Clusters in Turkish Children

    ERIC Educational Resources Information Center

    Gokgoz-Kurt, Burcu

    2017-01-01

    The current study provides a constraint-based analysis of L1 word-final consonant cluster acquisition in Turkish child language, based on the data originally presented by Topbas and Kopkalli-Yavuz (2008). The present analysis was done using [?]+obstruent consonant cluster acquisition. A comparison of Gradual Learning Algorithm (GLA) under…

  11. Comparison of Object-Based Image Analysis Approaches to Mapping New Buildings in Accra, Ghana Using Multi-Temporal QuickBird Satellite Imagery

    PubMed Central

    Tsai, Yu Hsin; Stow, Douglas; Weeks, John

    2013-01-01

    The goal of this study was to map and quantify the number of newly constructed buildings in Accra, Ghana between 2002 and 2010 based on high spatial resolution satellite image data. Two semi-automated feature detection approaches for detecting and mapping newly constructed buildings based on QuickBird very high spatial resolution satellite imagery were analyzed: (1) post-classification comparison; and (2) bi-temporal layerstack classification. Feature Analyst software based on a spatial contextual classifier and ENVI Feature Extraction that uses a true object-based image analysis approach of image segmentation and segment classification were evaluated. Final map products representing new building objects were compared and assessed for accuracy using two object-based accuracy measures, completeness and correctness. The bi-temporal layerstack method generated more accurate results compared to the post-classification comparison method due to less confusion with background objects. The spectral/spatial contextual approach (Feature Analyst) outperformed the true object-based feature delineation approach (ENVI Feature Extraction) due to its ability to more reliably delineate individual buildings of various sizes. Semi-automated, object-based detection followed by manual editing appears to be a reliable and efficient approach for detecting and enumerating new building objects. A bivariate regression analysis was performed using neighborhood-level estimates of new building density regressed on a census-derived measure of socio-economic status, yielding an inverse relationship with R2 = 0.31 (n = 27; p = 0.00). The primary utility of the new building delineation results is to support spatial analyses of land cover and land use and demographic change. PMID:24415810

  12. Meta-analysis: aerobic exercise for the treatment of anxiety disorders.

    PubMed

    Bartley, Christine A; Hay, Madeleine; Bloch, Michael H

    2013-08-01

    This meta-analysis investigates the efficacy of exercise as a treatment for DSM-IV diagnosed anxiety disorders. We searched PubMED and PsycINFO for randomized, controlled trials comparing the anxiolytic effects of aerobic exercise to other treatment conditions for DSM-IV defined anxiety disorders. Seven trials were included in the final analysis, totaling 407 subjects. The control conditions included non-aerobic exercise, waitlist/placebo, cognitive-behavioral therapy, psychoeducation and meditation. A fixed-effects model was used to calculate the standardized mean difference of change in anxiety rating scale scores of aerobic exercise compared to control conditions. Subgroup analyses were performed to examine the effects of (1) comparison condition; (2) whether comparison condition controlled for time spent exercising and (3) diagnostic indication. Aerobic exercise demonstrated no significant effect for the treatment of anxiety disorders (SMD=0.02 (95%CI: -0.20-0.24), z = 0.2, p = 0.85). There was significant heterogeneity between trials (χ(2) test for heterogeneity = 22.7, df = 6, p = 0.001). The reported effect size of aerobic exercise was highly influenced by the type of control condition. Trials utilizing waitlist/placebo controls and trials that did not control for exercise time reported large effects of aerobic exercise while other trials report no effect of aerobic exercise. Current evidence does not support the use of aerobic exercise as an effective treatment for anxiety disorders as compared to the control conditions. This remains true when controlling for length of exercise sessions and type of anxiety disorder. Future studies evaluating the efficacy of aerobic exercise should employ larger sample sizes and utilize comparison interventions that control for exercise time. Copyright © 2013. Published by Elsevier Inc.

  13. Enhanced Molecular Aging in Late-Life Depression: the Senescent-Associated Secretory Phenotype.

    PubMed

    Diniz, Breno Satler; Reynolds, Charles F; Sibille, Etienne; Lin, Chien-Wei; Tseng, George; Lotrich, Francis; Aizenstein, Howard J; Butters, Meryl A

    2017-01-01

    This study aims to investigate whether a systemic molecular pattern associated with aging (senescent-associated secretory phenotype [SASP]) is elevated in adults with late-life depression (LLD), compared with never-depressed elderly comparison participants. Cross-sectional study. We included 111 older adults (80 with LLD and 31 comparison participants) in this study. A panel of 22 SASP-related proteins was extracted from a previous multiplex protein panel performed in these participants. We conducted a principal component analysis to create the SASP index based on individual weights of each of protein. Participants with LLD showed a significantly increased SASP index compared with comparison participants, after controlling for age, depressive symptoms, medical comorbidity (CIRS-G) scores, sex, and cognitive performance (F (1,98)  = 7.3, p = 0.008). Correlation analyses revealed that the SASP index was positively correlated with age (r = 0.2, p = 0.03) and CIRS score (r = 0.27, p = 0.005), and negatively correlated with information processing speed (r = -0.34, p = 0.001), executive function (r = -0.27, p = 0.004) and global cognitive performance (r = -0.28, p = 0.007). To the best of our knowledge, this is the first study to show that a set of proteins (i.e., SASP index) primarily associated with cellular aging is abnormally regulated and elevated in LLD. These results suggest that individuals with LLD display enhanced aging-related molecular patterns that are associated with higher medical comorbidity and worse cognitive function. Finally, we provide a set of proteins that can serve as potential therapeutic targets and biomarkers to monitor the effects of therapeutic or preventative interventions in LLD. Copyright © 2017 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  14. Morphological and Glucose Metabolism Abnormalities in Alcoholic Korsakoff's Syndrome: Group Comparisons and Individual Analyses

    PubMed Central

    Pitel, Anne-Lise; Aupée, Anne-Marie; Chételat, Gaël; Mézenge, Florence; Beaunieux, Hélène; de la Sayette, Vincent; Viader, Fausto; Baron, Jean-Claude; Eustache, Francis; Desgranges, Béatrice

    2009-01-01

    Background Gray matter volume studies have been limited to few brain regions of interest, and white matter and glucose metabolism have received limited research attention in Korsakoff's syndrome (KS). Because of the lack of brain biomarkers, KS was found to be underdiagnosed in postmortem studies. Methodology/Principal Findings Nine consecutively selected patients with KS and 22 matched controls underwent both structural magnetic resonance imaging and 18F-fluorodeoxyglucose positron emission tomography examinations. Using a whole-brain analysis, the between-group comparisons of gray matter and white matter density and relative glucose uptake between patients with KS and controls showed the involvement of both the frontocerebellar and the Papez circuits, including morphological abnormalities in their nodes and connection tracts and probably resulting hypometabolism. The direct comparison of the regional distribution and degree of gray matter hypodensity and hypometabolism within the KS group indicated very consistent gray matter distribution of both abnormalities, with a single area of significant difference in the middle cingulate cortex showing greater hypometabolism than hypodensity. Finally, the analysis of the variability in the individual patterns of brain abnormalities within our sample of KS patients revealed that the middle cingulate cortex was the only brain region showing significant GM hypodensity and hypometabolism in each of our 9 KS patients. Conclusions/Significance These results indicate widespread brain abnormalities in KS including both gray and white matter damage mainly involving two brain networks, namely, the fronto-cerebellar circuit and the Papez circuit. Furthermore, our findings suggest that the middle cingulate cortex may play a key role in the pathophysiology of KS and could be considered as a potential in vivo brain biomarker. PMID:19936229

  15. Comparison between PGAA and ID-AMS analysis for determining chlorine content in whole rock basalt

    NASA Astrophysics Data System (ADS)

    di Nicola, L.; Schnabel, C.; Wilcken, K. M.; Gméling, K.

    2009-04-01

    Accurate determination of chlorine concentrations in terrestrial rocks is of importance for the interpretation of terrestrial in-situ cosmogenic 36Cl. Neutron capture by 35Cl, together with production from Ca and K, is one of the three major production pathways of 36Cl in rocks. Here, we present an inter-comparison of chlorine determinations by two procedures. The first approach is an independent Cl determination by prompt gamma (neutron) activation analysis (PGAA). The second method is isotope dilution based on isotopically-enriched stable chlorine carrier added during chemical sample preparation for accelerator mass spectrometry (ID-AMS). Twenty six (26) whole rock samples have been processed for PGAA and ID-AMS analyses. Elemental analysis by PGAA provides concentrations of major, minor and trace elements including the target elements for 36Cl production (K, Ca, Ti, and Fe), as well as of neutron absorbers and neutron moderators (H, B, Cl, Sm and Gd). The Cl concentrations determined during this study constitute the first inter-comparison for concentrations below 100 μCl/g. Our results show no significant difference in Cl concentrations between methods, and comparable uncertainties. This agreement guarantees that during the procedure we employ for whole rock sample no significant loss of stable chlorine from either the spike or the sample occurs before isotopic equilibration, prior to AgCl precipitation. Furthermore, we show that the elemental analysis by PGAA offers anadvance for the interpretation of 36Cl measurements. It allows simultaneous measurement of major and most trace element concentrations with a precision necessary for calculating the relative contributions to 36Cl production rates of the different mechanisms. Finally, the Cl concentration can be used to optimize the amount of isotopically-enriched spike for AMS-ID sample preparation for 36Cl.

  16. Enhanced molecular aging in late-life depression: the Senescent Associated Secretory Phenotype

    PubMed Central

    Diniz, Breno Satler; Reynolds, Charles F.; Sibille, Etienne; Lin, Chien-Wei; Tseng, George; Lotrich, Francis; Aizenstein, Howard J.; Butters, Meryl A.

    2016-01-01

    Objective This study aims to investigate whether a systemic molecular pattern associated with aging (senescent-associated secretory phenotype – SASP) is elevated in adults with late-life depression (LLD), compared to never-depressed elderly comparison participants. Design Cross-sectional study. Participants We included 111 older adults (80 with LLD and 31 comparison participants) in this study. Measurement A panel of 22 SASP-related proteins was extracted from a previous multiplex protein panel performed in these participants. We conducted a principal component analysis to create the SASP index based on individual weights of each of protein. Results Participants with LLD showed a significantly increased SASP index compared to comparison participants, after controlling for age, depressive symptoms, medical comorbidity (CIRS-G) scores, gender, and cognitive performance (F(1,98)=7.3, p=0.008). Correlation analyses revealed that the SASP index was positively correlated with age (r=0.2, p = 0.03) and CIRS score (r=0.27, p=0.005), and negatively correlated with information processing speed (r=−0.34, p=0.001), executive function (r=−0.27, p=0.004) and global cognitive performance (r=−0.28, p=0.007). Conclusions To the best of our knowledge, this is the first study to show that a set of proteins (i.e., SASP index) primarily associated with cellular aging, is abnormally regulated and elevated in LLD. These results suggest that individuals with LLD display enhanced aging-related molecular patterns that are associated with higher medical comorbidity and worse cognitive function. Finally, we provide a set of proteins that can serve as potential therapeutic targets and biomarkers to monitor the effects of therapeutic or preventative interventions in LLD. PMID:27856124

  17. Tri-level study of the causes of traffic accidents, volume 2 : special analyses.

    DOT National Transportation Integrated Search

    1979-05-01

    This final report is comprised of two volumes. Volume I provides causal result tabulations and related analyses. Volume II presents several special analysis reports dealing with driver vision knowledge, psychological make-up, etc. Human, environmenta...

  18. Thermal Control Surfaces Experiment

    NASA Technical Reports Server (NTRS)

    Wilkes, D. R.

    1999-01-01

    This report is the final experiment report for the TCSE and summarizes many years of hardware development and analyses. Also included are analyses presented in a number of TCSE papers that were prepared and given at scientific conferences including three LDEF Post-Retrieval Symposiums.

  19. Comparison of long-term evolutionary trajectories of two ephemeral channels after channel-forming extraordinary floods

    NASA Astrophysics Data System (ADS)

    Lotsari, Eliisa; House, Kyle; Alho, Petteri; Baker, Victor

    2017-04-01

    Analyses of the evolutionary trajectories of braided ephemeral channels enable identification of trends, magnitudes and periodicity of the processes that affect the channels. In addition to infrequent great floods, relatively frequent, small discharge events have been shown to be important for the evolution of ephemeral channels. However, evolutionary trajectories have rarely been studied in small ephemeral rivers, that predominantly transport gravel, cobles and boulders. Ephemeral tributary channels typify the Colorado River basin (USA), and two examples are Bronco Creek and Eldorado Canyon. These streams experienced extraordinary great floods in 1971 and 1974 respectively, and they are comparable to each other in both basin size, and climatic conditions. Annual precipitation is less than 50 cm, and the average temperature of each month is above 7°C. More importantly, earlier studies have shown similarities in the hydraulics and geomorphic characteristics of the extraordinary floods, which removed the pre-flood bar and braiding structure from the channels. Thus, these two channels are ideal for comparisons of their evolutionary trajecties. Moreover, the availability of high-resolutions aerial photographs for both channels since 1954 allowed for decadal analyses. Our research has analyzed and compared the long-term evolutionary trajectories of the two ephemeral channels within Colorado River Basin based on series of aerial photos and digital elevation models. (1) We detected the development and adjustment of braiding since the extraordinary floods. The detected parameters include the braiding index, bar area and number, channel area and width, confluence number and density, and the proportion of inactive and active areas. (2) We also analyzed the time required for the ephemeral river system to evolve back to its prior state before the high magnitude floods. Finally, (3) we analyzed whether these temporal changes in channel evolution can reveal new insights as to climatic and environmental conditions for these un-gauged basins.

  20. Evaluation and analysis of Seasat-A scanning multichannel Microwave Radiometer (SMMR) Antenna Pattern Correction (APC) algorithm

    NASA Technical Reports Server (NTRS)

    Kitzis, J. L.; Kitzis, S. N.

    1979-01-01

    The brightness temperature data produced by the SMMR final Antenna Pattern Correction (APC) algorithm is discussed. The algorithm consisted of: (1) a direct comparison of the outputs of the final and interim APC algorithms; and (2) an analysis of a possible relationship between observed cross track gradients in the interim brightness temperatures and the asymmetry in the antenna temperature data. Results indicate a bias between the brightness temperature produced by the final and interim APC algorithm.

Top