Osborne, Jason W
2006-05-01
D'Amico, Neilands, and Zambarano (2001) published SPSS syntax to perform power analyses for three complex procedures: ANCOVA, MANOVA, and repeated measures ANOVA. Unfortunately, the published SPSS syntax for performing the repeated measures analysis needed some minor revision in order to perform the analysis correctly. This article presents the corrected syntax that will successfully perform the repeated measures analysis and provides some guidance on modifying the syntax to customize the analysis.
[Analysis of variance of repeated data measured by water maze with SPSS].
Qiu, Hong; Jin, Guo-qin; Jin, Ru-feng; Zhao, Wei-kang
2007-01-01
To introduce the method of analyzing repeated data measured by water maze with SPSS 11.0, and offer a reference statistical method to clinical and basic medicine researchers who take the design of repeated measures. Using repeated measures and multivariate analysis of variance (ANOVA) process of the general linear model in SPSS and giving comparison among different groups and different measure time pairwise. Firstly, Mauchly's test of sphericity should be used to judge whether there were relations among the repeatedly measured data. If any (P
An, Shengli; Zhang, Yanhong; Chen, Zheng
2012-12-01
To analyze binary classification repeated measurement data with generalized estimating equations (GEE) and generalized linear mixed models (GLMMs) using SPSS19.0. GEE and GLMMs models were tested using binary classification repeated measurement data sample using SPSS19.0. Compared with SAS, SPSS19.0 allowed convenient analysis of categorical repeated measurement data using GEE and GLMMs.
Whole-animal metabolic rate is a repeatable trait: a meta-analysis.
Nespolo, Roberto F; Franco, Marcela
2007-06-01
Repeatability studies are gaining considerable interest among physiological ecologists, particularly in traits affected by high environmental/residual variance, such as whole-animal metabolic rate (MR). The original definition of repeatability, known as the intraclass correlation coefficient, is computed from the components of variance obtained in a one-way ANOVA on several individuals from which two or more measurements are performed. An alternative estimation of repeatability, popular among physiological ecologists, is the Pearson product-moment correlation between two consecutive measurements. However, despite the more than 30 studies reporting repeatability of MR, so far there is not a definite synthesis indicating: (1) whether repeatability changes in different types of animals; (2) whether some kinds of metabolism are more repeatable than others; and most important, (3) whether metabolic rate is significantly repeatable. We performed a meta-analysis to address these questions, as well as to explore the historical trend in repeatability studies. Our results show that metabolic rate is significantly repeatable and its effect size is not statistically affected by any of the mentioned factors (i.e. repeatability of MR does not change in different species, type of metabolism, time between measurements, and number of individuals). The cumulative meta-analysis revealed that repeatability studies in MR have already reached an asymptotical effect size with no further change either in its magnitude and/or variance (i.e. additional studies will not contribute significantly to the estimator). There was no evidence of strong publication bias.
D'Amico, E J; Neilands, T B; Zambarano, R
2001-11-01
Although power analysis is an important component in the planning and implementation of research designs, it is often ignored. Computer programs for performing power analysis are available, but most have limitations, particularly for complex multivariate designs. An SPSS procedure is presented that can be used for calculating power for univariate, multivariate, and repeated measures models with and without time-varying and time-constant covariates. Three examples provide a framework for calculating power via this method: an ANCOVA, a MANOVA, and a repeated measures ANOVA with two or more groups. The benefits and limitations of this procedure are discussed.
A LISREL Model for the Analysis of Repeated Measures with a Patterned Covariance Matrix.
ERIC Educational Resources Information Center
Rovine, Michael J.; Molenaar, Peter C. M.
1998-01-01
Presents a LISREL model for the estimation of the repeated measures analysis of variance (ANOVA) with a patterned covariance matrix. The model is demonstrated for a 5 x 2 (Time x Group) ANOVA in which the data are assumed to be serially correlated. Similarities with the Statistical Analysis System PROC MIXED model are discussed. (SLD)
Gnat, Rafael; Saulicz, Edward; Miądowicz, Barbara
2012-08-01
To investigate intra- and inter-rater reliability of the ultrasound measurement of transversus abdominis (TrA) thickness and thickness change (difference between thickness at rest and during contraction) in asymptomatic, trained subjects. To define the number of repeated measurements that provide acceptable level of reliability. To investigate variability of the measurements over time of 5 days and the reliability of duplicate analysis of images. A single-group repeated-measures design was used to assess reliability. Healthy volunteers (n = 10) were subjected to 1-week training in voluntary activation of TrA. Real-time ultrasound imaging and subsequent measurement of the TrA thickness at rest and during voluntary contraction were repeated on Monday, Wednesday and Friday of the next week. Using a single repeated measurement, intraclass correlation coefficients (ICCs) for TrA thickness were: 0.86-0.95 (intra-rater), 0.86-0.92 (inter-rater); and for TrA thickness change: 0.34-0.56 (intra-rater), 0.47-0.61 (inter-rater). Using the mean of three repeated measurements respective values were: 0.97, 0.96-0.98; and 0.81-0.84, 0.80-0.90. No significant differences were found between mean values of TrA thickness as well as thickness change obtained on three consecutive measurement days. Duplicate analysis of the images was highly reliable with ICCs of 0.89-0.99. Two repeated measurements for TrA thickness and at least three measurements for TrA thickness change are needed to achieve acceptable levels of intra- and inter-rater reliability. In healthy trained volunteers TrA thickness and thickness change are relatively stable parameters over a 5-day period. Duplicate analysis of the same images by two blinded observers is reliable.
Repeatability Modeling for Wind-Tunnel Measurements: Results for Three Langley Facilities
NASA Technical Reports Server (NTRS)
Hemsch, Michael J.; Houlden, Heather P.
2014-01-01
Data from extensive check standard tests of seven measurement processes in three NASA Langley Research Center wind tunnels are statistically analyzed to test a simple model previously presented in 2000 for characterizing short-term, within-test and across-test repeatability. The analysis is intended to support process improvement and development of uncertainty models for the measurements. The analysis suggests that the repeatability can be estimated adequately as a function of only the test section dynamic pressure over a two-orders- of-magnitude dynamic pressure range. As expected for low instrument loading, short-term coefficient repeatability is determined by the resolution of the instrument alone (air off). However, as previously pointed out, for the highest dynamic pressure range the coefficient repeatability appears to be independent of dynamic pressure, thus presenting a lower floor for the standard deviation for all three time frames. The simple repeatability model is shown to be adequate for all of the cases presented and for all three time frames.
Repeatability study of replicate crash tests: A signal analysis approach.
Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason
2017-10-03
To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.
Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.
Morgan, Timothy M; Case, L Douglas
2013-07-05
In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.
Lee, Jong-Hyuck; Kim, Jae Hyuck; Kim, Sun Woong
2017-02-27
To compare the repeatability of central corneal thickness (CCT) measurement using the Pentacam between dry eyes and healthy eyes, as well as to investigate the effect of artificial tears on CCT measurement. The corneal thicknesses of 34 patients with dry eye and 28 healthy subjects were measured using the Pentacam. One eye from each subject was assigned randomly to a repeatability test, wherein a single operator performed three successive CCT measurements time points-before and 5 min after instillation of one artificial teardrop. The repeatability of measurements was assessed using the coefficient of repeatability and the intraclass correlation coefficient. The coefficient of repeatability values of the CCT measurements in dry and healthy eyes were 24.36 and 10.69 μm before instillation, and 16.85 and 9.72 μm after instillation, respectively. The intraclass correlation coefficient was higher in healthy eyes than that of in dry eyes (0.987 vs. 0.891), and it had improved significantly in dry eyes (0.948) after instillation of one artificial teardrop. The CCT measurement fluctuated in dry eyes (repeated-measures analysis of variance, P<0.001), whereas no significant changes were detected in healthy eyes, either before or after artificial tear instillation. Central corneal thickness measurement is less repeatable in dry eyes than in healthy eyes. Artificial tears improve the repeatability of CCT measurements obtained using the Pentacam in dry eyes.
Precision and repeatability of the Optotrak 3020 motion measurement system.
States, R A; Pappas, E
2006-01-01
Several motion analysis systems are used by researchers to quantify human motion and to perform accurate surgical procedures. The Optotrak 3020 is one of these systems and despite its widespread use there is not any published information on its precision and repeatability. We used a repeated measures design study to evaluate the precision and repeatability of the Optotrak 3020 by measuring distance and angle in three sessions, four distances and three conditions (motion, static vertical, and static tilted). Precision and repeatability were found to be excellent for both angle and distance although they decreased with increasing distance from the sensors and with tilt from the plane of the sensors. Motion did not have a significant effect on the precision of the measurements. In conclusion, the measurement error of the Optotrak is minimal. Further studies are needed to evaluate its precision and repeatability under human motion conditions.
Analysis of longitudinal "time series" data in toxicology.
Cox, C; Cory-Slechta, D A
1987-02-01
Studies focusing on chronic toxicity or on the time course of toxicant effect often involve repeated measurements or longitudinal observations of endpoints of interest. Experimental design considerations frequently necessitate between-group comparisons of the resulting trends. Typically, procedures such as the repeated-measures analysis of variance have been used for statistical analysis, even though the required assumptions may not be satisfied in some circumstances. This paper describes an alternative analytical approach which summarizes curvilinear trends by fitting cubic orthogonal polynomials to individual profiles of effect. The resulting regression coefficients serve as quantitative descriptors which can be subjected to group significance testing. Randomization tests based on medians are proposed to provide a comparison of treatment and control groups. Examples from the behavioral toxicology literature are considered, and the results are compared to more traditional approaches, such as repeated-measures analysis of variance.
Parel, I; Cutti, A G; Kraszewski, A; Verni, G; Hillstrom, H; Kontaxis, A
2014-03-01
Multi-center clinical trials incorporating shoulder kinematics are currently uncommon. The absence of repeatability and limits of agreement (LoA) studies between different centers employing different motion analysis protocols has led to a lack dataset compatibility. Therefore, the aim of this work was to determine the repeatability and LoA between two shoulder kinematic protocols. The first one uses a scapula tracker (ST), the International Society of Biomechanics anatomical frames and an optoelectronic measurement system, and the second uses a spine tracker, the INAIL Shoulder and Elbow Outpatient protocol (ISEO) and an inertial and magnetic measurement system. First within-protocol repeatability for each approach was assessed on a group of 23 healthy subjects and compared with the literature. Then, the between-protocol agreement was evaluated. The within-protocol repeatability was similar for the ST ([Formula: see text] = 2.35°, [Formula: see text] = 0.97°, SEM = 2.5°) and ISEO ([Formula: see text] = 2.24°, [Formula: see text] = 0.97°, SEM = 2.3°) protocols and comparable with data from published literature. The between-protocol agreement analysis showed comparable scapula medio-lateral rotation measurements for up to 120° of flexion-extension and up to 100° of scapula plane ab-adduction. Scapula protraction-retraction measurements were in agreement for a smaller range of humeral elevation. The results of this study suggest comparable repeatability for the ST and ISEO protocols and between-protocol agreement for two scapula rotations. Different thresholds for repeatability and LoA may be adapted to suit different clinical hypotheses.
Measurement system analysis of viscometers used for drilling mud characterization
NASA Astrophysics Data System (ADS)
Mat-Shayuti, M. S.; Adzhar, S. N.
2017-07-01
Viscometers in the Faculty of Chemical Engineering, University Teknologi MARA, are subject to heavy utilization from the members of the faculty. Due to doubts surrounding their result integrity and maintenance management, Measurement System Analysis was executed. 5 samples of drilling muds with varied barite content from 5 - 25 weight% were prepared and their rheological properties determined in 3 trials by 3 operators using the viscometers. Gage Linearity and Bias Study were performed using Minitab software and the result shows high biases in the range of 19.2% to 38.7%, with non-linear trend along the span of measurements. Gage Repeatability & Reproducibility (Nested) analysis later produces Percent Repeatability & Reproducibility more than 7.7% and Percent Tolerance above 30%. Lastly, good and marginal Distinct Categories output are seen among the results. Despite acceptable performance of the measurement system in Distinct Categories, the poor results in accuracy, linearity, and Percent Repeatability & Reproducibility render the gage generally not capable. Improvement to the measurement system is imminent.
2013-11-06
the Scree plot (Figure 3) and the analysis was repeated saving these four factors. The Kaiser - Meyer - Olkin measure of sampling adequacy was .95...the Scree plot (Figure 4) and the analysis was repeated saving these three factors. The Kaiser - Meyer - Olkin measure of sampling adequacy was .90, above
Jaworski, Artur; Kuszewski, Hubert; Ustrzycki, Adam; Balawender, Krzysztof; Lejda, Kazimierz; Woś, Paweł
2018-04-20
Measurement of car engines exhaust pollutants emissions is very important because of their harmful effects on the environment. This article presents the assessment of repeatability of the passenger car engine exhaust pollutants emission research results obtained in the conditions of a chassis dynamometer. The research was conducted in a climate chamber, enabling the temperature conditions to be determined from - 20 to + 30 °C. The emission of CO, CH 4 , CO 2 , NO X , THC, and NMHC was subjected to the analysis. The aim of the research is to draw attention to the accuracy of the pollutant emission research results in driving cycles, and the comparison of pollutant emission results and their repeatability obtained in successive NEDC cycles under cold and hot start conditions. The results of the analysis show that, in the case of a small number of measurements, the results repeatability analysis is necessary for a proper interpretation of the pollutant emission results on the basis of the mean value. According to the authors' judgment, it is beneficial to determine the coefficient of variation for a more complete assessment of exhaust emission result repeatability obtained from a small number of measurements. This parameter is rarely presented by the authors of papers on exhaust components emission research.
Testing Multiple Outcomes in Repeated Measures Designs
ERIC Educational Resources Information Center
Lix, Lisa M.; Sajobi, Tolulope
2010-01-01
This study investigates procedures for controlling the familywise error rate (FWR) when testing hypotheses about multiple, correlated outcome variables in repeated measures (RM) designs. A content analysis of RM research articles published in 4 psychology journals revealed that 3 quarters of studies tested hypotheses about 2 or more outcome…
Placebo non-response measure in sequential parallel comparison design studies.
Rybin, Denis; Doros, Gheorghe; Pencina, Michael J; Fava, Maurizio
2015-07-10
The Sequential Parallel Comparison Design (SPCD) is one of the novel approaches addressing placebo response. The analysis of SPCD data typically classifies subjects as 'placebo responders' or 'placebo non-responders'. Most current methods employed for analysis of SPCD data utilize only a part of the data collected during the trial. A repeated measures model was proposed for analysis of continuous outcomes that permitted the inclusion of information from all subjects into the treatment effect estimation. We describe here a new approach using a weighted repeated measures model that further improves the utilization of data collected during the trial, allowing the incorporation of information that is relevant to the placebo response, and dealing with the problem of possible misclassification of subjects. Our simulations show that when compared to the unweighted repeated measures model method, our approach performs as well or, under certain conditions, better, in preserving the type I error, achieving adequate power and minimizing the mean squared error. Copyright © 2015 John Wiley & Sons, Ltd.
Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz
2017-01-01
Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017
A Primer on Longitudinal Data Analysis in Education. Technical Report #1320
ERIC Educational Resources Information Center
Nese, Joseph F. T.; Lai, Cheng-Fei; Anderson, Daniel
2013-01-01
Longitudinal data analysis in education is the study growth over time. A longitudinal study is one in which repeated observations of the same variables are recorded for the same individuals over a period of time. This type of research is known by many names (e.g., time series analysis or repeated measures design), each of which can imply subtle…
Rosenblatt, Alana J; Scrivani, Peter V; Boisclair, Yves R; Reeves, Anthony P; Ramos-Nieves, Jose M; Xie, Yiting; Erb, Hollis N
2017-10-01
Computed tomography (CT) is a suitable tool for measuring body fat, since it is non-destructive and can be used to differentiate metabolically active visceral fat from total body fat. Whole body analysis of body fat is likely to be more accurate than single CT slice estimates of body fat. The aim of this study was to assess the agreement between semi-automated computer analysis of whole body volumetric CT data and conventional proximate (chemical) analysis of body fat in lambs. Data were collected prospectively from 12 lambs that underwent duplicate whole body CT, followed by slaughter and carcass analysis by dissection and chemical analysis. Agreement between methods for quantification of total and visceral fat was assessed by Bland-Altman plot analysis. The repeatability of CT was assessed for these measures using the mean difference of duplicated measures. When compared to chemical analysis, CT systematically underestimated total and visceral fat contents by more than 10% of the mean fat weight. Therefore, carcass analysis and semi-automated CT computer measurements were not interchangeable for quantifying body fat content without the use of a correction factor. CT acquisition was repeatable, with a mean difference of repeated measures being close to zero. Therefore, uncorrected whole body CT might have an application for assessment of relative changes in fat content, especially in growing lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Repeatability of DTI-based skeletal muscle fiber tracking
Heemskerk, Anneriet M.; Sinha, Tuhin K.; Wilson, Kevin J.; Ding, Zhaohua; Damon, Bruce M.
2015-01-01
Diffusion tensor imaging (DTI)-based muscle fiber tracking enables the measurement of muscle architectural parameters, such as pennation angle (θ) and fiber tract length (Lft), throughout the entire muscle. Little is known, however, about the repeatability of either the muscle architectural measures or the underlying diffusion measures. Therefore, the goal of this study was to investigate the repeatability of DTI fiber tracking-based measurements and θ and Lft. Four DTI acquisitions were performed on two days that allowed for between acquisition, within day, and between day analyses. The eigenvalues and fractional anisotropy were calculated at the maximum cross-sectional area of, and fiber tracking was performed in, the tibialis anterior muscle of nine healthy subjects. The between acquisitions condition had the highest repeatability for the DTI indices and the architectural parameters. The overall inter class correlation coefficients (ICC’s) were greater than 0.6 for both θ and Lft and the repeatability coefficients were θ <10.2° and Lft < 50 mm. In conclusion, under the experimental and data analysis conditions used, the repeatability of the diffusion measures is very good and repeatability of the architectural measurements is acceptable. Therefore, this study demonstrates the feasibility for longitudinal studies of alterations in muscle architecture using DTI-based fiber tracking, under similar noise conditions and with similar diffusion characteristics. PMID:20099372
On the repeated measures designs and sample sizes for randomized controlled trials.
Tango, Toshiro
2016-04-01
For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Omnibus Tests for Interactions in Repeated Measures Designs with Dichotomous Dependent Variables.
ERIC Educational Resources Information Center
Serlin, Ronald C.; Marascuilo, Leonard A.
When examining a repeated measures design with independent groups for a significant group by trial interaction, classical analysis of variance or multivariate procedures can be used if the assumptions underlying the tests are met. Neither procedure may be justified for designs with small sample sizes and dichotomous dependent variables. An omnibus…
Short- and long-term variability of radon progeny concentration in dwellings in the Czech Republic.
Slezáková, M; Navrátilová Rovenská, K; Tomásek, L; Holecek, J
2013-03-01
In this paper, repeated measurements of radon progeny concentration in dwellings in the Czech Republic are described. Two distinct data sets are available: one based on present measurements in 170 selected dwellings in the Central Bohemian Pluton with a primary measurement carried out in the 1990s and the other based on 1920 annual measurements in 960 single-family houses in the Czech Republic in 1992 and repeatedly in 1993. The analysis of variance model with random effects is applied to data to evaluate the variability of measurements. The calculated variability attributable to repeated measurements is compared with results from other countries. In epidemiological studies, ignoring the variability of measurements may lead to biased estimates of risk of lung cancer.
Ogungbenro, Kayode; Aarons, Leon
2011-08-01
In the recent years, interest in the application of experimental design theory to population pharmacokinetic (PK) and pharmacodynamic (PD) experiments has increased. The aim is to improve the efficiency and the precision with which parameters are estimated during data analysis and sometimes to increase the power and reduce the sample size required for hypothesis testing. The population Fisher information matrix (PFIM) has been described for uniresponse and multiresponse population PK experiments for design evaluation and optimisation. Despite these developments and availability of tools for optimal design of population PK and PD experiments much of the effort has been focused on repeated continuous variable measurements with less work being done on repeated discrete type measurements. Discrete data arise mainly in PDs e.g. ordinal, nominal, dichotomous or count measurements. This paper implements expressions for the PFIM for repeated ordinal, dichotomous and count measurements based on analysis by a mixed-effects modelling technique. Three simulation studies were used to investigate the performance of the expressions. Example 1 is based on repeated dichotomous measurements, Example 2 is based on repeated count measurements and Example 3 is based on repeated ordinal measurements. Data simulated in MATLAB were analysed using NONMEM (Laplace method) and the glmmML package in R (Laplace and adaptive Gauss-Hermite quadrature methods). The results obtained for Examples 1 and 2 showed good agreement between the relative standard errors obtained using the PFIM and simulations. The results obtained for Example 3 showed the importance of sampling at the most informative time points. Implementation of these expressions will provide the opportunity for efficient design of population PD experiments that involve discrete type data through design evaluation and optimisation.
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Holmes, D. R., III; Gunawan, M. S.; Ge, X.; Karwoski, R. A.; Breen, J. F.; Packer, D. L.; Robb, R. A.
2012-03-01
Geometric analysis of the left atrium and pulmonary veins is important for studying reverse structural remodeling following cardiac ablation therapy. It has been shown that the left atrium decreases in volume and the pulmonary vein ostia decrease in diameter following ablation therapy. Most analysis techniques, however, require laborious manual tracing of image cross-sections. Pulmonary vein diameters are typically measured at the junction between the left atrium and pulmonary veins, called the pulmonary vein ostia, with manually drawn lines on volume renderings or on image cross-sections. In this work, we describe a technique for making semi-automatic measurements of the left atrium and pulmonary vein ostial diameters from high resolution CT scans and multi-phase datasets. The left atrium and pulmonary veins are segmented from a CT volume using a 3D volume approach and cut planes are interactively positioned to separate the pulmonary veins from the body of the left atrium. The cut plane is also used to compute the pulmonary vein ostial diameter. Validation experiments are presented which demonstrate the ability to repeatedly measure left atrial volume and pulmonary vein diameters from high resolution CT scans, as well as the feasibility of this approach for analyzing dynamic, multi-phase datasets. In the high resolution CT scans the left atrial volume measurements show high repeatability with approximately 4% intra-rater repeatability and 8% inter-rater repeatability. Intra- and inter-rater repeatability for pulmonary vein diameter measurements range from approximately 2 to 4 mm. For the multi-phase CT datasets, differences in left atrial volumes between a standard slice-by-slice approach and the proposed 3D volume approach are small, with percent differences on the order of 3% to 6%.
Validity and repeatability of inertial measurement units for measuring gait parameters.
Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli
2017-06-01
Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.
A novel method to measure femoral component migration by computed tomography: a cadaver study.
Boettner, Friedrich; Sculco, Peter; Lipman, Joseph; Renner, Lisa; Faschingbauer, Martin
2016-06-01
Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.
Pairwise Multiple Comparisons in Single Group Repeated Measures Analysis.
ERIC Educational Resources Information Center
Barcikowski, Robert S.; Elliott, Ronald S.
Research was conducted to provide educational researchers with a choice of pairwise multiple comparison procedures (P-MCPs) to use with single group repeated measures designs. The following were studied through two Monte Carlo (MC) simulations: (1) The T procedure of J. W. Tukey (1953); (2) a modification of Tukey's T (G. Keppel, 1973); (3) the…
Takács, Péter
2016-01-01
We compared the repeatability, reproducibility (intra- and inter-measurer similarity), separative power and subjectivity (measurer effect on results) of four morphometric methods frequently used in ichthyological research, the “traditional” caliper-based (TRA) and truss-network (TRU) distance methods and two geometric methods that compare landmark coordinates on the body (GMB) and scales (GMS). In each case, measurements were performed three times by three measurers on the same specimen of three common cyprinid species (roach Rutilus rutilus (Linnaeus, 1758), bleak Alburnus alburnus (Linnaeus, 1758) and Prussian carp Carassius gibelio (Bloch, 1782)) collected from three closely-situated sites in the Lake Balaton catchment (Hungary) in 2014. TRA measurements were made on conserved specimens using a digital caliper, while TRU, GMB and GMS measurements were undertaken on digital images of the bodies and scales. In most cases, intra-measurer repeatability was similar. While all four methods were able to differentiate the source populations, significant differences were observed in their repeatability, reproducibility and subjectivity. GMB displayed highest overall repeatability and reproducibility and was least burdened by measurer effect. While GMS showed similar repeatability to GMB when fish scales had a characteristic shape, it showed significantly lower reproducability (compared with its repeatability) for each species than the other methods. TRU showed similar repeatability as the GMS. TRA was the least applicable method as measurements were obtained from the fish itself, resulting in poor repeatability and reproducibility. Although all four methods showed some degree of subjectivity, TRA was the only method where population-level detachment was entirely overwritten by measurer effect. Based on these results, we recommend a) avoidance of aggregating different measurer’s datasets when using TRA and GMS methods; and b) use of image-based methods for morphometric surveys. Automation of the morphometric workflow would also reduce any measurer effect and eliminate measurement and data-input errors. PMID:27327896
Analysis and discussion on the experimental data of electrolyte analyzer
NASA Astrophysics Data System (ADS)
Dong, XinYu; Jiang, JunJie; Liu, MengJun; Li, Weiwei
2018-06-01
In the subsequent verification of electrolyte analyzer, we found that the instrument can achieve good repeatability and stability in repeated measurements with a short period of time, in line with the requirements of verification regulation of linear error and cross contamination rate, but the phenomenon of large indication error is very common, the measurement results of different manufacturers have great difference, in order to find and solve this problem, help enterprises to improve quality of product, to obtain accurate and reliable measurement data, we conducted the experimental evaluation of electrolyte analyzer, and the data were analyzed by statistical analysis.
Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky
2014-06-01
To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.
Repeatability of intravital capillaroscopic measurement of capillary density.
Lamah, M; Chaudhry, H; Mortimer, P S; Dormandy, J A
1996-01-01
The reliability of intravital capillaroscopy for determining capillary density (CD) of skin has been questioned because it depends upon the variability of the measuring process and subjective interpretation of data as well as the intrinsic heterogeneity of capillary spacing. The aim of this study was to assess the repeatability of a standardised method for measuring CD of the skin of the dorsum of foot. In each of 30 subjects (10 controls and 20 patients with peripheral vascular disease), the foot was systematically mapped by examining 20 sites on the dorsum of foot and 2 sites on each toe, using white light (native) videomicroscopy at 40 x magnification. Off-line analysis of videoprints was then undertaken to determine CD at each site, by counting capillaries within areas of acceptable photographic quality only, having first defined the criteria for counting capillaries. The mean values were then calculated and taken to represent the CD of the foot or toes. Repeatability of the measuring equipment was first assessed by noting the presence or absence of each corresponding capillary in 2 prints, taken at intervals of hours or days (in 10 subjects) or months (in 2 patients), of an identical area of skin which was marked by a microtattoo on the first occasion. On average, 95% of corresponding capillaries were identified in both prints (from controls and patients), thus implying little intrinsic temporal variation of capillary anatomy as well as excellent repeatability of the measuring equipment. Repeatability of data analysis was assessed by the same observer reading the same 20 prints in a blinded manner on three separate occasions (intraobserver repeatability), and 2 observers reading the same 24 prints (interobserver repeatability). The mean coefficient of intraobserver variation of CD estimate was 5.6% and the interobserver correlation coefficient was 0.94. Finally, overall repeatability of the method was assessed by repeating the procedure on a subsequent occasion (mean time interval of 5 days) in 10 subjects. The rate of agreement in mean CD between the two procedures [defined as 100- (difference between the two measurements/mean of the two measurements) x 100]% ranged from 86.4 to 97.1% (mean 93.5%). Thus using the above methodological technique, native capillaroscopy can be reliably used to determine CD of the dorsum of foot in comparing patient subgroups, as well as in longitudinal studies.
Hudson, John M; Milot, Laurent; Parry, Craig; Williams, Ross; Burns, Peter N
2013-06-01
This study assessed the reproducibility of shear wave elastography (SWE) in the liver of healthy volunteers. Intra- and inter-operator reliability and repeatability were quantified in three different liver segments in a sample of 15 subjects, scanned during four independent sessions (two scans on day 1, two scans 1 wk later) by two operators. A total of 1440 measurements were made. Reproducibility was assessed using the intra-class correlation coefficient (ICC) and a repeated measures analysis of variance. The shear wave speed was measured and used to estimate Young's modulus using the Supersonics Imagine Aixplorer. The median Young's modulus measured through the inter-costal space was 5.55 ± 0.74 kPa. The intra-operator reliability was better for same-day evaluations (ICC = 0.91) than the inter-operator reliability (ICC = 0.78). Intra-observer agreement decreased when scans were repeated on a different day. Inter-session repeatability was between 3.3% and 9.9% for intra-day repeated scans, compared with to 6.5%-12% for inter-day repeated scans. No significant difference was observed in subjects with a body mass index greater or less than 25 kg/m(2). Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Keegan, Kevin G; Kramer, Joanne; Yonezawa, Yoshiharu; Maki, Hiromitchi; Pai, P Frank; Dent, Eric V; Kellerman, Thomas E; Wilson, David A; Reed, Shannon K
2011-09-01
To determine repeatability of a wireless, inertial sensor-based lameness evaluation system in horses. 236 horses. Horses were from 2 to 29 years of age and of various breeds and lameness disposition. All horses were instrumented with a wireless, inertial sensor-based motion analysis system on the head (accelerometer), pelvis (midline croup region [accelerometer]), and right forelimb (gyroscope) before evaluation in 2 consecutive trials, approximately 5 minutes apart, as the horse was trotted in a straight line. Signal-processing algorithms generated overall trial asymmetry measures for vertical head and pelvic movement and stride-by-stride differences in head and pelvic maximum and minimum positions between right and left sides of each stride. Repeatability was determined, and trial difference was determined for groups of horses with various numbers of strides for which data were collected per trial. Inertial sensor-based measures of torso movement asymmetry were repeatable. Repeatability for measures of torso asymmetry for determination of hind limb lameness was slightly greater than that for forelimb lameness. Collecting large numbers of strides degraded stride-to-stride repeatability but did not degrade intertrial repeatability. The inertial sensor system used to measure asymmetry of head and pelvic movement as an aid in the detection and evaluation of lameness in horses trotting in a straight line was sufficiently repeatable to investigate for clinical use.
Analysis of a kinetic multi-segment foot model. Part I: Model repeatability and kinematic validity.
Bruening, Dustin A; Cooney, Kevin M; Buczek, Frank L
2012-04-01
Kinematic multi-segment foot models are still evolving, but have seen increased use in clinical and research settings. The addition of kinetics may increase knowledge of foot and ankle function as well as influence multi-segment foot model evolution; however, previous kinetic models are too complex for clinical use. In this study we present a three-segment kinetic foot model and thorough evaluation of model performance during normal gait. In this first of two companion papers, model reference frames and joint centers are analyzed for repeatability, joint translations are measured, segment rigidity characterized, and sample joint angles presented. Within-tester and between-tester repeatability were first assessed using 10 healthy pediatric participants, while kinematic parameters were subsequently measured on 17 additional healthy pediatric participants. Repeatability errors were generally low for all sagittal plane measures as well as transverse plane Hindfoot and Forefoot segments (median<3°), while the least repeatable orientations were the Hindfoot coronal plane and Hallux transverse plane. Joint translations were generally less than 2mm in any one direction, while segment rigidity analysis suggested rigid body behavior for the Shank and Hindfoot, with the Forefoot violating the rigid body assumptions in terminal stance/pre-swing. Joint excursions were consistent with previously published studies. Copyright © 2012 Elsevier B.V. All rights reserved.
Reinstein, Dan Z.; Archer, Timothy J.; Silverman, Ronald H.; Coleman, D. Jackson
2008-01-01
Purpose To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. Setting London Vision Clinic, London, United Kingdom. Methods A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. Results The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. Conclusion The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment. PMID:17081860
Rate-loss analysis of an efficient quantum repeater architecture
NASA Astrophysics Data System (ADS)
Guha, Saikat; Krovi, Hari; Fuchs, Christopher A.; Dutton, Zachary; Slater, Joshua A.; Simon, Christoph; Tittel, Wolfgang
2015-08-01
We analyze an entanglement-based quantum key distribution (QKD) architecture that uses a linear chain of quantum repeaters employing photon-pair sources, spectral-multiplexing, linear-optic Bell-state measurements, multimode quantum memories, and classical-only error correction. Assuming perfect sources, we find an exact expression for the secret-key rate, and an analytical description of how errors propagate through the repeater chain, as a function of various loss-and-noise parameters of the devices. We show via an explicit analytical calculation, which separately addresses the effects of the principle nonidealities, that this scheme achieves a secret-key rate that surpasses the Takeoka-Guha-Wilde bound—a recently found fundamental limit to the rate-vs-loss scaling achievable by any QKD protocol over a direct optical link—thereby providing one of the first rigorous proofs of the efficacy of a repeater protocol. We explicitly calculate the end-to-end shared noisy quantum state generated by the repeater chain, which could be useful for analyzing the performance of other non-QKD quantum protocols that require establishing long-distance entanglement. We evaluate that shared state's fidelity and the achievable entanglement-distillation rate, as a function of the number of repeater nodes, total range, and various loss-and-noise parameters of the system. We extend our theoretical analysis to encompass sources with nonzero two-pair-emission probability, using an efficient exact numerical evaluation of the quantum state propagation and measurements. We expect our results to spur formal rate-loss analysis of other repeater protocols and also to provide useful abstractions to seed analyses of quantum networks of complex topologies.
Analysis of repeat-mediated deletions in the mitochondrial genome of Saccharomyces cerevisiae.
Phadnis, Naina; Sia, Rey A; Sia, Elaine A
2005-12-01
Mitochondrial DNA deletions and point mutations accumulate in an age-dependent manner in mammals. The mitochondrial genome in aging humans often displays a 4977-bp deletion flanked by short direct repeats. Additionally, direct repeats flank two-thirds of the reported mitochondrial DNA deletions. The mechanism by which these deletions arise is unknown, but direct-repeat-mediated deletions involving polymerase slippage, homologous recombination, and nonhomologous end joining have been proposed. We have developed a genetic reporter to measure the rate at which direct-repeat-mediated deletions arise in the mitochondrial genome of Saccharomyces cerevisiae. Here we analyze the effect of repeat size and heterology between repeats on the rate of deletions. We find that the dependence on homology for repeat-mediated deletions is linear down to 33 bp. Heterology between repeats does not affect the deletion rate substantially. Analysis of recombination products suggests that the deletions are produced by at least two different pathways, one that generates only deletions and one that appears to generate both deletions and reciprocal products of recombination. We discuss how this reporter may be used to identify the proteins in yeast that have an impact on the generation of direct-repeat-mediated deletions.
Analysis of Repeat-Mediated Deletions in the Mitochondrial Genome of Saccharomyces cerevisiae
Phadnis, Naina; Sia, Rey A.; Sia, Elaine A.
2005-01-01
Mitochondrial DNA deletions and point mutations accumulate in an age-dependent manner in mammals. The mitochondrial genome in aging humans often displays a 4977-bp deletion flanked by short direct repeats. Additionally, direct repeats flank two-thirds of the reported mitochondrial DNA deletions. The mechanism by which these deletions arise is unknown, but direct-repeat-mediated deletions involving polymerase slippage, homologous recombination, and nonhomologous end joining have been proposed. We have developed a genetic reporter to measure the rate at which direct-repeat-mediated deletions arise in the mitochondrial genome of Saccharomyces cerevisiae. Here we analyze the effect of repeat size and heterology between repeats on the rate of deletions. We find that the dependence on homology for repeat-mediated deletions is linear down to 33 bp. Heterology between repeats does not affect the deletion rate substantially. Analysis of recombination products suggests that the deletions are produced by at least two different pathways, one that generates only deletions and one that appears to generate both deletions and reciprocal products of recombination. We discuss how this reporter may be used to identify the proteins in yeast that have an impact on the generation of direct-repeat-mediated deletions. PMID:16157666
DOE Office of Scientific and Technical Information (OSTI.GOV)
2014-06-11
This program is a graphical user interface for measuring and performing inter-active analysis of physical unclonable functions (PUFs). It is intended for demonstration and education purposes. See license.txt for license details. The program features a PUF visualization that demonstrates how signatures differ between PUFs and how they exhibit noise over repeated measurements. A similarity scoreboard shows the user how close the current measurement is to the closest chip signatures in the database. Other metrics such as average noise and inter-chip Hamming distances are presented to the user. Randomness tests published in NIST SP 800-22 can be computed and displayed. Noisemore » and inter-chip histograms for the sample of PUFs and repeated PUF measurements can be drawn.« less
Östling, Gerd; Nilsson, Peter M.
2015-01-01
Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079
Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei
2015-10-01
To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Oliveira, Tássia Boeno de; Azevedo Peixoto, Leonardo de; Teodoro, Paulo Eduardo; Alvarenga, Amauri Alves de; Bhering, Leonardo Lopes; Campo, Clara Beatriz Hoffmann
2018-01-01
Asian rust affects the physiology of soybean plants and causes losses in yield. Repeatability coefficients may help breeders to know how many measurements are needed to obtain a suitable reliability for a target trait. Therefore, the objectives of this study were to determine the repeatability coefficients of 14 traits in soybean plants inoculated with Phakopsora pachyrhizi and to establish the minimum number of measurements needed to predict the breeding value with high accuracy. Experiments were performed in a 3x2 factorial arrangement with three treatments and two inoculations in a random block design. Repeatability coefficients, coefficients of determination and number of measurements needed to obtain a certain reliability were estimated using ANOVA, principal component analysis based on the covariance matrix and the correlation matrix, structural analysis and mixed model. It was observed that the principal component analysis based on the covariance matrix out-performed other methods for almost all traits. Significant differences were observed for all traits except internal CO2 concentration for the treatment effects. For the measurement effects, all traits were significantly different. In addition, significant differences were found for all Treatment x Measurement interaction traits except coumestrol, chitinase and chlorophyll content. Six measurements were suitable to obtain a coefficient of determination higher than 0.7 for all traits based on principal component analysis. The information obtained from this research will help breeders and physiologists determine exactly how many measurements are needed to evaluate each trait in soybean plants infected by P. pachyrhizi with a desirable reliability.
de Oliveira, Tássia Boeno; Teodoro, Paulo Eduardo; de Alvarenga, Amauri Alves; Bhering, Leonardo Lopes; Campo, Clara Beatriz Hoffmann
2018-01-01
Asian rust affects the physiology of soybean plants and causes losses in yield. Repeatability coefficients may help breeders to know how many measurements are needed to obtain a suitable reliability for a target trait. Therefore, the objectives of this study were to determine the repeatability coefficients of 14 traits in soybean plants inoculated with Phakopsora pachyrhizi and to establish the minimum number of measurements needed to predict the breeding value with high accuracy. Experiments were performed in a 3x2 factorial arrangement with three treatments and two inoculations in a random block design. Repeatability coefficients, coefficients of determination and number of measurements needed to obtain a certain reliability were estimated using ANOVA, principal component analysis based on the covariance matrix and the correlation matrix, structural analysis and mixed model. It was observed that the principal component analysis based on the covariance matrix out-performed other methods for almost all traits. Significant differences were observed for all traits except internal CO2 concentration for the treatment effects. For the measurement effects, all traits were significantly different. In addition, significant differences were found for all Treatment x Measurement interaction traits except coumestrol, chitinase and chlorophyll content. Six measurements were suitable to obtain a coefficient of determination higher than 0.7 for all traits based on principal component analysis. The information obtained from this research will help breeders and physiologists determine exactly how many measurements are needed to evaluate each trait in soybean plants infected by P. pachyrhizi with a desirable reliability. PMID:29438380
Self-Administered Questionnaire Is a Reliable Measure of Coffee Consumption
Sääksjärvi, Katri; Knekt, Paul; Männistö, Satu; Heliövaara, Markku
2010-01-01
Background The objective of this study was to assess the agreement and repeatability of 2 methods of measuring habitual coffee consumption, and to examine their homogeneity with respect to socioeconomic and lifestyle factors. Methods Data on coffee consumption were collected from 4254 subjects by means of a health questionnaire (HQ) and a 1-year dietary history interview (DHI), the latter of which was used as the reference method during the Finnish Mobile Clinic Health Examination Survey conducted in 1973–1976. Short-term repeatability of the methods was assessed using data from 286 and 93 subjects who repeated the HQ and the DHI, respectively, after an interval of 4 to 8 months. The strength of agreement between the 2 methods and between the repeated measurements was estimated using intraclass correlation coefficients (ICCs). Results The ICC was 0.86 for the agreement between the HQ and the DHI, and 0.77 and 0.85 for the repeatability of the HQ and the DHI, respectively. There were no statistically significant systematic differences in mean intake values between the 2 methods or between repeated measurements. In subgroup analysis of background variables, there were only minor differences in agreement and repeatability, with somewhat higher ICC values among subjects with a healthier lifestyle and higher education. Conclusions The high reliability and homogeneity of the health questionnaire make it a useful tool for measuring habitual coffee consumption for the purposes of epidemiological research. PMID:20671374
Agreement and repeatability of objective systems for assessment of the tear film.
Fernández, Joaquín; Rodríguez-Vallejo, Manuel; Martínez, Javier; Tauste, Ana; García-Montesinos, Javier; Piñero, David P
2018-04-18
To assess the agreement and repeatability of two objective systems for measuring the tear film stability. Retrospective analysis of the tear film stability of 99 healthy right eyes measured with a videokeratoscope (VK) and the Optical Quality Analysis System (OQAS, Visiometrics). Two consecutive measures were taken with both systems, with an interval of 10 min between them. Variables included in the study were first and mean non-invasive break-up times (NIBUT and MNIBUT) measured with VK, and mean and standard deviation of the optical scattering index (OSIm and OSIsd) measured with OQAS. The agreement and repeatability of grading scales provided by both devices were also evaluated using the Cohen's k with quadratic weights. The Ocular Surface Disease index (OSDI) questionnaire was also passed out to all subjects. Correlations and associations between subjective and objective metrics were analyzed. Significant differences were found between consecutive measurements of NIBUT (p = 0.04) and MNIBUT (p = 0.01), but not for OSIm (p = 0.11) and OSIsd (p = 0.50). Grading scales resulted in fair (k = 0.20) or poor agreement (k = 0.04) between systems depending if the first or second trial was considered. The repeatability of the grading scale was good for OQAS (k = 0.59) and fair for VK (k = 0.37). No significant correlations or associations were found between OSDI and any of the metrics obtained with both devices (p ≥ 0.36). The two devices evaluated cannot be used interchangeably for the assessment of tear film stability. Good intrasession repeatability was obtained for tear film grading of the OQAS whereas it was fair for VK.
Borsa, Paul A.; Liggett, Charles L.
1998-01-01
Objective: To assess the therapeutic effects of flexible magnets on pain perception, intramuscular swelling, range of motion, and muscular strength in individuals with a muscle microinjury. Design and Setting: This experiment was a single-blind, placebo study using a repeated-measures design. Subjects performed an intense exercise protocol to induce a muscle microinjury. After pretreatment measurements were recorded, subjects were randomly assigned to an experimental (magnet), placebo (imitation magnet), or control (no magnet) group. Posttreatment measurements were repeated at 24, 48, and 72 hours. Subjects: Forty-five healthy subjects participated in the study. Measurements: Subjects were measured repeatedly for pain perception, upper arm girth, range of motion, and static force production. Four separate univariate analyses of variances were used to reveal statistically significant mean (±SD) differences between variables over time. Interaction effects were analyzed using Scheffe post hoc analysis. Results: Analysis of variance revealed no statistically significant (P > .05) mean differences between conditions for any dependent pretreatment and posttreatment measurements. No significant interaction effects were demonstrated between conditions and times. Conclusions: No significant therapeutic effects on pain control and muscular dysfunction were observed in subjects wearing flexible magnets. ImagesFig 2.Fig 3. PMID:16558503
Addison, Elena S; Clements, Dylan N
2017-12-01
Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.
Tomlinson, Mathew James; Pooley, Karen; Simpson, Tracey; Newton, Thomas; Hopkisson, James; Jayaprakasan, Kannamanadias; Jayaprakasan, Rajisha; Naeem, Asad; Pridmore, Tony
2010-04-01
To determine the accuracy and precision of a novel computer-assisted sperm analysis (CASA) system by comparison with existing recommended manual methods. Prospective study using comparative measurements of sperm concentration and motility on latex beads and immotile and motile sperm. Tertiary referral fertility center with strong academic links. Sperm donors and male partners of couples attending for fertility investigations. None. Achievement of Accubead target value for high and low concentration suspensions. Repeatability as demonstrated by coefficients of variation and intraclass correlation coefficients. Correlation and limits of agreement between CASA and manual methods. The CASA measurements of latex beads and sperm concentrations demonstrated a high level of accuracy and repeatability. Repeated Accubead measurements attained the required target value (mean difference from target of 2.61% and 3.71% for high- and low-concentration suspensions, respectively) and were highly reproducible. Limits of agreement analysis suggested that manual and CASA counts compared directly could be deemed to be interchangeable. Manual and CASA motility measurements were highly correlated for grades a, b, and d but could not be deemed to be interchangeable, and manual motility estimates were consistently higher for motile sperm. The novel CASA system was able to provide semen quality measurements for sperm concentration and motility measurements which were at least as reliable as current manual methods. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Ounsi, Hani F; Franciosi, Giovanni; Paragliola, Raffaele; Al-Hezaimi, Khalid; Salameh, Ziad; Tay, Franklin R; Ferrari, Marco; Grandini, Simone
2011-06-01
The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Fabrizi, Sarah E; Ito, Max A; Winston, Kristin
2016-01-01
This study's objective was to investigate the effects of a community playgroup on the playfulness of children with special needs ages 15 mo to 3 yr and the responsiveness of their caregivers. Using a pretest-posttest, repeated-measures design, we evaluated 8 child-caregiver dyads participating in an 8-wk occupational therapist-led community playgroup recruited from a purposive sample enrolled in early intervention. Video recordings from four time points over 4 mo were used to determine playfulness (Test of Playfulness) of the child and the responsiveness of the caregiver. Blinded raters assessed playfulness and responsiveness outcomes. A repeated-measures analysis of variance demonstrated that participation in the playgroup significantly increased child playfulness (ηp² = .89, p < .01). Analysis did not detect a change in caregiver responsiveness. The results of this study have implications for the use of playgroups in comprehensive occupational therapy practice in early intervention. Copyright © 2016 by the American Occupational Therapy Association, Inc.
Validation of Fourier analysis of videokeratographic data.
Sideroudi, Haris; Labiris, Georgios; Ditzel, Fienke; Tsaragli, Efi; Georgatzoglou, Kimonas; Siganos, Haralampos; Kozobolis, Vassilios
2017-06-15
The aim was to assess the repeatability of Fourier transfom analysis of videokeratographic data using Pentacam in normal (CG), keratoconic (KC) and post-CXL (CXL) corneas. This was a prospective, clinic-based, observational study. One randomly selected eye from all study participants was included in the analysis: 62 normal eyes (CG group), 33 keratoconus eyes (KC group), while 34 eyes, which had already received CXL treatment, formed the CXL group. Fourier analysis of keratometric data were obtained using Pentacam, by two different operators within each of two sessions. Precision, repeatability and Intraclass Correlation Coefficient (ICC), were calculated for evaluating intrassesion and intersession repeatability for the following parameters: Spherical Component (SphRmin, SphEcc), Maximum Decentration (Max Dec), Regular Astigmatism, and Irregularitiy (Irr). Bland-Altman analysis was used for assessing interobserver repeatability. All parameters were presented to be repeatable, reliable and reproductible in all groups. Best intrasession and intersession repeatability and reliability were detected for parameters SphRmin, SphEcc and Max Dec parameters for both operators using ICC (intrasession: ICC > 98%, intersession: ICC > 94.7%) and within subject standard deviation. Best precision and lowest range of agreement was found for the SphRmin parameter (CG: 0.05, KC: 0.16, and CXL: 0.2) in all groups, while the lowest repeatability, reliability and reproducibility was detected for the Irr parameter. The Pentacam system provides accurate measurements of Fourier tranform keratometric data. A single Pentacam scan will be sufficient for most clinical applications.
Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin
2017-01-01
Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.
Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang
2016-06-01
This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.
Griffiths, Clive; Murray, Alan; Zheng, Dingchang
2016-01-01
Objective This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Methods Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. Results There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). Conclusion This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant. PMID:26741415
NASA Astrophysics Data System (ADS)
Efseaff, Matthew
Rubidium-82 positron emission tomography (PET) imaging has been proposed for routine myocardial blood flow (MBF) quantification. Few studies have investigated the test-retest repeatability of this method. Same-day repeatability of rest MBF imaging was optimized with a highly automated analysis program using image-derived input functions and a dual spillover correction (SOC). The effects of heterogeneous tracer infusion profiles and subject hemodynamics on test-retest repeatability were investigated at rest and during hyperemic stress. Factors affecting rest MBF repeatability included gender, suspected coronary artery disease, and dual SOC (p < 0.001). The best repeatability coefficient for same-day rest MBF was 0.20 mL/min/g using a six-minute scan-time, iterative reconstruction, dual SOC, resting rate-pressure-product (RPP) adjustment, and a left atrium image-derived input function. The serial study repeatabilities of the optimized protocol in subjects with homogeneous RPPs and tracer infusion profiles was 0.19 and 0.53 mL/min/g at rest and stress, and 0.95 for stress / rest myocardial flow reserve (MFR). Subjects with heterogeneous tracer infusion profiles and hemodynamic conditions had significantly less repeatable MBF measurements at rest, stress, and stress/rest flow reserve (p < 0.05).
On the analysis of very small samples of Gaussian repeated measurements: an alternative approach.
Westgate, Philip M; Burchett, Woodrow W
2017-03-15
The analysis of very small samples of Gaussian repeated measurements can be challenging. First, due to a very small number of independent subjects contributing outcomes over time, statistical power can be quite small. Second, nuisance covariance parameters must be appropriately accounted for in the analysis in order to maintain the nominal test size. However, available statistical strategies that ensure valid statistical inference may lack power, whereas more powerful methods may have the potential for inflated test sizes. Therefore, we explore an alternative approach to the analysis of very small samples of Gaussian repeated measurements, with the goal of maintaining valid inference while also improving statistical power relative to other valid methods. This approach uses generalized estimating equations with a bias-corrected empirical covariance matrix that accounts for all small-sample aspects of nuisance correlation parameter estimation in order to maintain valid inference. Furthermore, the approach utilizes correlation selection strategies with the goal of choosing the working structure that will result in the greatest power. In our study, we show that when accurate modeling of the nuisance correlation structure impacts the efficiency of regression parameter estimation, this method can improve power relative to existing methods that yield valid inference. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Minimum number of measurements for evaluating soursop (Annona muricata L.) yield.
Sánchez, C F B; Teodoro, P E; Londoño, S; Silva, L A; Peixoto, L A; Bhering, L L
2017-05-31
Repeatability studies on fruit species are of great importance to identify the minimum number of measurements necessary to accurately select superior genotypes. This study aimed to identify the most efficient method to estimate the repeatability coefficient (r) and predict the minimum number of measurements needed for a more accurate evaluation of soursop (Annona muricata L.) genotypes based on fruit yield. Sixteen measurements of fruit yield from 71 soursop genotypes were carried out between 2000 and 2016. In order to estimate r with the best accuracy, four procedures were used: analysis of variance, principal component analysis based on the correlation matrix, principal component analysis based on the phenotypic variance and covariance matrix, and structural analysis based on the correlation matrix. The minimum number of measurements needed to predict the actual value of individuals was estimated. Principal component analysis using the phenotypic variance and covariance matrix provided the most accurate estimates of both r and the number of measurements required for accurate evaluation of fruit yield in soursop. Our results indicate that selection of soursop genotypes with high fruit yield can be performed based on the third and fourth measurements in the early years and/or based on the eighth and ninth measurements at more advanced stages.
NASA Astrophysics Data System (ADS)
Murphy, Kellie A.
This thesis investigated possible changes in performance after one month of vitamin D supplementation in individuals found to be vitamin D deficient or insufficient through blood spot testing. Thirty-two males, ages 18-32, participated. Each subject visited the lab three times in one-month, completing four performance tests each session, including an isometric mid-thigh pull and a vertical jump on a force plate, a isometric 90-degree elbow flexion test using a load cell, and a psychomotor vigilance test on a palm pilot. The initial lab included blood spot tests to find vitamin D levels. In a single blind manner, 16 subjects were assigned vitamin D and 16 the placebo. Repeated measures ANOVA analysis did not reveal any main effects for time (F=2.626, p=0.364), treatment (vitamin D3 vs placebo; F=1.282, p=0.999), or interaction effects for treatment by time (F=0.304, p=0.999) for maximum force production during an isometric mid-thigh pull. Repeated measures ANOVA analysis did not reveal any main effects for time (F=1.323, p=0.999), treatment (vitamin D3 vs placebo; F=0.510, p=0.999), or interaction effects for treatment by time (F= 1.625, p=0.860) for rate of force production during a vertical jump. Repeated measures ANOVA analysis did not reveal any main effects for time (F=0.194, p=0.999), treatment (vitamin D3 vs placebo; F=2.452, p=0.513), or interaction effects for treatment by time (F= 1.179, p=0.999) for maximal force production during a 90-degree isometric elbow flexion. Repeated measures ANOVA analysis did not reveal any main effects for time (F=1.710, p=0.804), treatment (vitamin D3 vs placebo; F=1.471, p=0.94), or interaction effects for treatment by time (F= 0.293, p=0.999) for mean reaction time to random stimuli during the psychomotor vigilance test. Repeated measures ANOVA analysis did not reveal any main effects for time (F=0.530, p=0.999), treatment (vitamin D3 vs placebo; F=0.141, p=0.999), or interaction effects for treatment by time (F=0.784 p=0.999) for incidence of minor lapses during the psychomotor vigilance test.
Vossoughi, Mehrdad; Ayatollahi, S M T; Towhidi, Mina; Ketabchi, Farzaneh
2012-03-22
The summary measure approach (SMA) is sometimes the only applicable tool for the analysis of repeated measurements in medical research, especially when the number of measurements is relatively large. This study aimed to describe techniques based on summary measures for the analysis of linear trend repeated measures data and then to compare performances of SMA, linear mixed model (LMM), and unstructured multivariate approach (UMA). Practical guidelines based on the least squares regression slope and mean of response over time for each subject were provided to test time, group, and interaction effects. Through Monte Carlo simulation studies, the efficacy of SMA vs. LMM and traditional UMA, under different types of covariance structures, was illustrated. All the methods were also employed to analyze two real data examples. Based on the simulation and example results, it was found that the SMA completely dominated the traditional UMA and performed convincingly close to the best-fitting LMM in testing all the effects. However, the LMM was not often robust and led to non-sensible results when the covariance structure for errors was misspecified. The results emphasized discarding the UMA which often yielded extremely conservative inferences as to such data. It was shown that summary measure is a simple, safe and powerful approach in which the loss of efficiency compared to the best-fitting LMM was generally negligible. The SMA is recommended as the first choice to reliably analyze the linear trend data with a moderate to large number of measurements and/or small to moderate sample sizes.
Barrett, Jessica; Pennells, Lisa; Sweeting, Michael; Willeit, Peter; Di Angelantonio, Emanuele; Gudnason, Vilmundur; Nordestgaard, Børge G.; Psaty, Bruce M; Goldbourt, Uri; Best, Lyle G; Assmann, Gerd; Salonen, Jukka T; Nietert, Paul J; Verschuren, W. M. Monique; Brunner, Eric J; Kronmal, Richard A; Salomaa, Veikko; Bakker, Stephan J L; Dagenais, Gilles R; Sato, Shinichi; Jansson, Jan-Håkan; Willeit, Johann; Onat, Altan; de la Cámara, Agustin Gómez; Roussel, Ronan; Völzke, Henry; Dankner, Rachel; Tipping, Robert W; Meade, Tom W; Donfrancesco, Chiara; Kuller, Lewis H; Peters, Annette; Gallacher, John; Kromhout, Daan; Iso, Hiroyasu; Knuiman, Matthew; Casiglia, Edoardo; Kavousi, Maryam; Palmieri, Luigi; Sundström, Johan; Davis, Barry R; Njølstad, Inger; Couper, David; Danesh, John; Thompson, Simon G; Wood, Angela
2017-01-01
Abstract The added value of incorporating information from repeated blood pressure and cholesterol measurements to predict cardiovascular disease (CVD) risk has not been rigorously assessed. We used data on 191,445 adults from the Emerging Risk Factors Collaboration (38 cohorts from 17 countries with data encompassing 1962–2014) with more than 1 million measurements of systolic blood pressure, total cholesterol, and high-density lipoprotein cholesterol. Over a median 12 years of follow-up, 21,170 CVD events occurred. Risk prediction models using cumulative mean values of repeated measurements and summary measures from longitudinal modeling of the repeated measurements were compared with models using measurements from a single time point. Risk discrimination (C-index) and net reclassification were calculated, and changes in C-indices were meta-analyzed across studies. Compared with the single-time-point model, the cumulative means and longitudinal models increased the C-index by 0.0040 (95% confidence interval (CI): 0.0023, 0.0057) and 0.0023 (95% CI: 0.0005, 0.0042), respectively. Reclassification was also improved in both models; compared with the single-time-point model, overall net reclassification improvements were 0.0369 (95% CI: 0.0303, 0.0436) for the cumulative-means model and 0.0177 (95% CI: 0.0110, 0.0243) for the longitudinal model. In conclusion, incorporating repeated measurements of blood pressure and cholesterol into CVD risk prediction models slightly improves risk prediction. PMID:28549073
Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter
Venkataraman, Arvind; Mardi, Sapna K; Pillai, Sarita
2010-01-01
Purpose: To compare horizontal corneal diameter measurements using the Orbscan Eyemetrics function and Orbscan corneal topographer. Materials and Methods: Seventy-three eyes of 37 patients were included in the study. In all cases, the automated white-to-white (WTW) measurements were obtained using Orbscan by two observers. Using the Eyemetrics function, the WTW was measured manually by the same observers from limbus to limbus using the digital caliper passing through the five point corneal reflections on the Orbscan real image. The data was analyzed using SPSS software for correlation, reliability and inter-rater repeatability. Results: The mean horizontal corneal diameter was 11.74 ± 0.32mm (SD) with the Orbscan and 11.92 ± 0.33mm (SD) with Eyemetrics Software-based measurement. A good positive correlation (Spearman r = 0.720, P = 0.026) was found between these two measurements. The coefficient of inter-rater repeatability was 0.89 for the Orbscan and 0.94 for the Eyemetrics software measurements on the anterior segment images. The Bland and Altman analysis showed large limits of agreement between Orbscan WTW and Eyemetrics WTW measurements. The intra-session repeatability scores for repeat measurements for the Orbscan WTW and Eyemetrics measurements were good. Conclusion: Eyemetrics can be used to measure WTW and the Eyemetrics measured WTW was longer than the WTW measured by Orbscan. PMID:20413925
Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E
2011-05-01
Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test-retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3-34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=-1.05 was significantly different from the hypothesized value. The Tonosafe test-retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.
Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E
2011-01-01
Purpose Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Methods Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test–retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. Results The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3–34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=−1.05 was significantly different from the hypothesized value. The Tonosafe test–retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. Conclusions The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings. PMID:21455241
Image analysis of oronasal fistulas in cleft palate patients acquired with an intraoral camera.
Murphy, Tania C; Willmot, Derrick R
2005-01-01
The aim of this study was to examine the clinical technique of using an intraoral camera to monitor the size of residual oronasal fistulas in cleft lip-cleft palate patients, to assess its repeatability on study casts and patients, and to compare its use with other methods. Seventeen plaster study casts of cleft palate patients with oronasal fistulas obtained from a 5-year series of 160 patients were used. For the clinical study, 13 patients presenting in a clinic prospectively over a 1-year period were imaged twice by the camera. The area of each fistula on each study cast was measured in the laboratory first using a previously described graph paper and caliper technique and second with the intraoral camera. Images were imported into a computer and subjected to image enhancement and area measurement. The camera was calibrated by imaging a standard periodontal probe within the fistula area. The measurements were repeated using a double-blind technique on randomly renumbered casts to assess the repeatability of measurement of the methods. The clinical images were randomly and blindly numbered and subjected to image enhancement and processing in the same way as for the study casts. Area measurements were computed. Statistical analysis of repeatability of measurement using a paired sample t test showed no significant difference between measurements, indicating a lack of systematic error. An intraclass correlation coefficient of 0.97 for the graph paper and 0.84 for the camera method showed acceptable random error between the repeated records for each of the two methods. The graph paper method remained slightly more repeatable. The mean fistula area of the study casts between each method was not statistically different when compared with a paired samples t test (p = 0.08). The methods were compared using the limits of agreement technique, which showed clinically acceptable repeatability. The clinical study of repeated measures showed no systematic differences when subjected to a t test (p = 0.109) and little random error with an intraclass correlation coefficient of 0.98. The fistula size seen in the clinical study ranged from 18.54 to 271.55 mm. Direct measurements subsequently taken on 13 patients in the clinic without study models showed a wide variation in the size of residual fistulas presenting in a multidisciplinary clinic. It was concluded that an intraoral camera method could be used in place of the previous graph paper method and could be developed for clinical and scientific purposes. This technique may offer advantages over the graph paper method, as it facilitates easy visualization of oronasal fistulas and objective fistulas size determination and permits easy storage of data in clinical records.
Continued investigation of potential application of Omega navigation to civil aviation
NASA Technical Reports Server (NTRS)
Baxa, E. G., Jr.
1978-01-01
Major attention is given to an analysis of receiver repeatability in measuring OMEGA phase data. Repeatability is defined as the ability of two like receivers which are co-located to achieve the same LOP phase readings. Specific data analysis is presented. A propagation model is described which has been used in the analysis of propagation anomalies. Composite OMEGA analysis is presented in terms of carrier phase correlation analysis and the determination of carrier phase weighting coefficients for minimizing composite phase variation. Differential OMEGA error analysis is presented for receiver separations. Three frequency analysis includes LOP error and position error based on three and four OMEGA transmissions. Results of phase amplitude correlation studies are presented.
REPLICATIONS AND EXTENSIONS IN AROUSAL ASSESSMENT FOR SEX OFFENDERS WITH DEVELOPMENTAL DISABILITIES
Reyes, Jorge R; Vollmer, Timothy R; Hall, Astrid
2011-01-01
Three adult male sex offenders with developmental disabilities participated in phallometric assessments that involved repeated measures of arousal when exposed to various stimuli. Arousal assessment outcomes were similar to those obtained by Reyes et al. (2006). Additional data-analysis methods provided further information about sexual preferences, thus replicating and extending previous research. The results provide preliminary data for establishing a preference gradient by age. Implications for the use of repeated measures and preference gradients in arousal assessments are discussed. PMID:21709795
The effect of repeated firings on the color change and surface roughness of dental ceramics
Yılmaz, Kerem; Ozturk, Caner
2014-01-01
PURPOSE The color of the ceramic restorations is affected by various factors such as brand, thickness of the layered the ceramic, condensation techniques, smoothness of surface, number of firings, firing temperature and thickness of dentin. The aim of this study was to evaluate the color change and surface roughness in dental porcelain with different thicknesses during repeated firings. MATERIALS AND METHODS Disc-shaped (N=21) metal-ceramic samples (IPS Classic; Ivoclar Vivadent; Shaar, Liechtenstein) with different thickness were exposed to repeated firings. Color measurement of the samples was made using a colorimeter and profilometer was used to determine surface roughness. ANOVA and Tukey tests with repeated measurements were used for statistical analysis. RESULTS The total thickness of the ceramics which is less than 2 mm significantly have detrimental effect on the surface properties and color of porcelains during firings (P<.05). CONCLUSION Repeated firings have effects on the color change and surface roughness of the dental ceramics and should be avoided. PMID:25177475
A high-precision velocity measuring system design for projectiles based on S-shaped laser screen
NASA Astrophysics Data System (ADS)
Liu, Huayi; Qian, Zheng; Yu, Hao; Li, Yutao
2018-03-01
The high-precision measurement of the velocity of high-speed flying projectile is of great significance for the evaluation and development of modern weapons. The velocity of the high-speed flying projectile is usually measured by laser screen velocity measuring system. But this method cannot achieve the repeated measurements, so we cannot make an indepth evaluation of the uncertainty about the measuring system. This paper presents a design based on S-shaped laser screen velocity measuring system. This design can achieve repeated measurements. Therefore, it can effectively reduce the uncertainty of the velocity measuring system. In addition, we made a detailed analysis of the uncertainty of the measuring system. The measurement uncertainty is 0.2% when the velocity of the projectile is about 200m/s.
Analysis of repeated measurement data in the clinical trials
Singh, Vineeta; Rana, Rakesh Kumar; Singhal, Richa
2013-01-01
Statistics is an integral part of Clinical Trials. Elements of statistics span Clinical Trial design, data monitoring, analyses and reporting. A solid understanding of statistical concepts by clinicians improves the comprehension and the resulting quality of Clinical Trials. In biomedical research it has been seen that researcher frequently use t-test and ANOVA to compare means between the groups of interest irrespective of the nature of the data. In Clinical Trials we record the data on the patients more than two times. In such a situation using the standard ANOVA procedures is not appropriate as it does not consider dependencies between observations within subjects in the analysis. To deal with such types of study data Repeated Measure ANOVA should be used. In this article the application of One-way Repeated Measure ANOVA has been demonstrated by using the software SPSS (Statistical Package for Social Sciences) Version 15.0 on the data collected at four time points 0 day, 15th day, 30th day, and 45th day of multicentre clinical trial conducted on Pandu Roga (~Iron Deficiency Anemia) with an Ayurvedic formulation Dhatrilauha. PMID:23930038
NASA Astrophysics Data System (ADS)
Hahn, Gitte Holst; Christensen, Karl Bang; Leung, Terence S.; Greisen, Gorm
2010-05-01
Coherence between spontaneous fluctuations in arterial blood pressure (ABP) and the cerebral near-infrared spectroscopy signal can detect cerebral autoregulation. Because reliable measurement depends on signals with high signal-to-noise ratio, we hypothesized that coherence is more precisely determined when fluctuations in ABP are large rather than small. Therefore, we investigated whether adjusting for variability in ABP (variabilityABP) improves precision. We examined the impact of variabilityABP within the power spectrum in each measurement and between repeated measurements in preterm infants. We also examined total monitoring time required to discriminate among infants with a simulation study. We studied 22 preterm infants (GA<30) yielding 215 10-min measurements. Surprisingly, adjusting for variabilityABP within the power spectrum did not improve the precision. However, adjusting for the variabilityABP among repeated measurements (i.e., weighting measurements with high variabilityABP in favor of those with low) improved the precision. The evidence of drift in individual infants was weak. Minimum monitoring time needed to discriminate among infants was 1.3-3.7 h. Coherence analysis in low frequencies (0.04-0.1 Hz) had higher precision and statistically more power than in very low frequencies (0.003-0.04 Hz). In conclusion, a reliable detection of cerebral autoregulation takes hours and the precision is improved by adjusting for variabilityABP between repeated measurements.
Fortes, Paula Madeira; Albrechet-Souza, Lucas; Vasconcelos, Mailton; Ascoli, Bruna Maria; Menegolla, Ana Paula; de Almeida, Rosa Maria M
2017-01-01
Agonistic behaviors help to ensure survival, provide advantage in competition, and communicate social status. The resident-intruder paradigm, an animal model based on male intraspecific confrontations, can be an ethologically relevant tool to investigate the neurobiology of aggressive behavior. To examine behavioral and neurobiological mechanisms of aggressive behavior in male Swiss mice exposed to repeated confrontations in the resident intruder paradigm. Behavioral analysis was performed in association with measurements of plasma corticosterone of mice repeatedly exposed to a potential rival nearby, but inaccessible (social instigation), or to 10 sessions of social instigation followed by direct aggressive encounters. Moreover, corticotropin-releasing factor (CRF) and brain-derived neurotrophic factor (BNDF) were measured in the brain of these animals. Control mice were exposed to neither social instigation nor aggressive confrontations. Mice exposed to aggressive confrontations exhibited a similar pattern of species-typical aggressive and non-aggressive behaviors on the first and the last session. Moreover, in contrast to social instigation only, repeated aggressive confrontations promoted an increase in plasma corticosterone. After 10 aggressive confrontation sessions, mice presented a non-significant trend toward reducing hippocampal levels of CRF, which inversely correlated with plasma corticosterone levels. Conversely, repeated sessions of social instigation or aggressive confrontation did not alter BDNF concentrations at the prefrontal cortex and hippocampus. Exposure to repeated episodes of aggressive encounters did not promote habituation over time. Additionally, CRF seems to be involved in physiological responses to social stressors.
Strampe, Margaret R; Huckenpahler, Alison L; Higgins, Brian P; Tarima, Sergey; Visotcky, Alexis; Stepien, Kimberly E; Kay, Christine N; Carroll, Joseph
2018-05-01
To examine repeatability and reproducibility of ellipsoid zone (EZ) width measurements in patients with retinitis pigmentosa (RP) using a longitudinal reflectivity profile (LRP) analysis. We examined Bioptigen optical coherence tomography (OCT) scans from 48 subjects with RP or Usher syndrome. Nominal scan lengths were 6, 7, or 10 mm, and the lateral scale of each scan was calculated using axial length measurements. LRPs were generated from OCT line scans, and the peak corresponding to EZ was manually identified using ImageJ. The locations at which the EZ peak disappeared were used to calculate EZ width. Each scan was analyzed twice by each of two observers, who were masked to their previous measurements and those of the other observer. On average, horizontal width (HW) was significantly greater than vertical width (VW), and there was high interocular symmetry for both HW and VW. We observed excellent intraobserver repeatability with intraclass correlation coefficients (ICCs) ranging from 0.996 to 0.998 for HW and VW measurements. Interobserver reproducibility was also excellent for both HW (ICC = 0.989; 95% confidence interval [CI] = 0.983-0.995) and VW (ICC = 0.991; 95% CI = 0.985-0.996), with no significant bias observed between observers. EZ width can be measured using LRPs with excellent repeatability and reproducibility. Our observation of greater HW than VW is consistent with previous observations in RP, though the reason for this anisotropy remains unclear. We describe repeatability and reproducibility of a method for measuring EZ width in patients with RP or Usher syndrome. This approach could facilitate measurement of retinal band thickness and/or intensity.
An evaluation of various methods of treatment for Legg-Calvé-Perthes disease.
Wang, L; Bowen, J R; Puniak, M A; Guille, J T; Glutting, J
1995-05-01
An analysis of 5 methods of treatment for Legg-Calvé-Perthes disease was done on 124 patients with 141 affected hips. Before treatment, all groups were statistically similar concerning initial Mose measurement, age at onset of the disease, gender, and Catterall class. Treatments included the Scottish Rite orthosis (41 hips), nonweight bearing and exercises (41 hips), Petrie cast (29 hips), femoral varus osteotomy (15 hips), or Salter osteotomy (15 hips). Hips treated by the Scottish Rite orthosis had a significantly worse Mose measurement across time interaction (repeated measures analysis of variance, post hoc analyses, p < 0.05). For the other 4 treatment methods, there was no statistically different change. At followup, the Mose measurements for hips treated with the Scottish Rite orthosis were significantly worse than those for hips treated by nonweight bearing and exercises, Petrie cast, varus osteotomy, or Salter osteotomy (repeated measures analysis of variance, post hoc analyses, p < 0.05). There was, however, no significant difference in the distribution of hips according to the Stulberg et al classification at the last followup.
Repeatability of standard metabolic rate (SMR) in a small fish, the spined loach (Cobitis taenia).
Maciak, Sebastian; Konarzewski, Marek
2010-10-01
Significant repeatability of a trait of interest is an essential assumption for undertaking studies of phenotypic variability. It is especially important in studies on highly variable traits, such as metabolic rates. Recent publications suggest that resting/basal metabolic rate of homeotherms is repeatable across wide range of species. In contrast, studies on the consistency of standard metabolic rate (SMR) in ectotherms, particularly fish, are scarce. Here we present a comprehensive analysis of several important technical aspects of body mass-corrected SMR measurements and its repeatability in a small (average weight approximately 3g) fish, the spined loach (Cobitis taenia). First we demonstrated that release of oxygen from the walls of metabolic chambers exposed to hypoxic conditions did not confound SMR measurements. Next, using principle of propagation of measurement uncertainties we demonstrated that in aquatic systems, measurement error is significantly higher in open than closed respirometry setups. The measurement error for SMR of a small fish determined in a closed aquatic system is comparable to that obtainable using top-notch open-flow systems used for air-breathing terrestrial animals. Using a closed respirometer we demonstrated that body mass-corrected SMR in spined loaches was repeatable under both normoxia and hypoxia over a 5-month period (Pearson correlation r=0.68 and r=0.73, respectively) as well as across both conditions (intraclass correlation coefficient tau=0.30). In these analyses we accounted for possible effect of oxygen consumption of the oxygen electrode on repeatability of SMR. Significant SMR consistency was accompanied by significant repeatability of body mass (intraclass correlation coefficient tau=0.86). To our knowledge, this is the first study showing long-term repeatability of body mass and SMR in a small fish, and is consistent with the existence of heritable variation of these two traits. 2010 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Y; Fuller, C; Mohamed, A
2015-06-15
Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients weremore » scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.« less
Alamidi, Daniel F; Smailagic, Amir; Bidar, Abdel W; Parker, Nicole S; Olsson, Marita; Hockings, Paul D; Lagerstrand, Kerstin M; Olsson, Lars E
2018-03-08
Lung T 1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T 1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. To evaluate the feasibility of regional lung T 1 quantification with VFA 3D-UTE and to investigate long- and short-term T 1 repeatability in the lungs of naive mice. Prospective preclinical animal study. Eight naive mice and phantoms. 3D free-breathing radial UTE (8 μs) at 4.7T. VFA 3D-UTE T 1 calculations were validated against T 1 values measured with inversion recovery (IR) in phantoms. Lung T 1 and proton density (S 0 ) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T 1 measurements were performed during one of the imaging sessions. Agreement in T 1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson 's correlation analysis. The T 1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. Good T 1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T 1 in lung and muscle showed a 5% and 3% CV (1255 ± 63 msec and 1432 ± 42 msec, respectively, mean ± SD) with no changes in T 1 or S 0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T 1 and S 0 . VFA 3D-UTE shows promise as a reliable T 1 mapping method that enables full lung coverage, high signal-to-noise ratio (∼25), and spatial resolution (300 μm) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Padayachy, Llewellyn C; Padayachy, Vaishali; Galal, Ushma; Gray, Rebecca; Fieggen, A Graham
2016-10-01
The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97-0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.
Katoh, Hiroshi; Subandiyah, Siti; Tomimura, Kenta; Okuda, Mitsuru; Su, Hong-Ji; Iwanami, Toru
2011-01-01
Four highly polymorphic simple sequence repeat (SSR) loci were selected and used to differentiate 84 Japanese isolates of “Candidatus Liberibacter asiaticus.” The Nei's measure of genetic diversity values for these four SSRs ranged from 0.60 to 0.86. The four SSR loci were also highly polymorphic in four isolates from Taiwan and 12 isolates from Indonesia. PMID:21239554
Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente
2014-06-01
The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p < 0.05), suggesting excellent reliability of the measurements. Muscle-fat fraction measurements from water-fat MRI exhibited the highest intraclass correlation coefficient. Interrater agreement was consistently better than test-retest comparisons. Water-fat MRI and DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.
Thirty-minute compared to standardised office blood pressure measurement in general practice
Scherpbier-de Haan, Nynke; van der Wel, Mark; Schoenmakers, Gijs; Boudewijns, Steve; Peer, Petronella; van Weel, Chris; Thien, Theo; Bakx, Carel
2011-01-01
Background Although blood pressure measurement is one of the most frequently performed measurements in clinical practice, there are concerns about its reliability. Serial, automated oscillometric blood pressure measurement has the potential to reduce measurement bias and white-coat effect' Aim To study agreement of 30-minute office blood pressure measurement (OBPM) with standardised OBPM, and to compare repeatability Design and setting Method comparison study in two general practices in the Netherlands Method Thirty-minute and standardised OBPM was carried out with the same, validated device in 83 adult patients, and the procedure was repeated after 2 weeks. During 30-minute OBPM, blood pressure was measured automatically every 3 minutes, with the patient in a sitting position, alone in a quiet room. Agreement between 30-minute and standardised OBPM was assessed by Bland–Altman analysis. Repeatability of the blood pressure measurement methods after 2 weeks was expressed as the mean difference in combination with the standard deviation of difference (SDD) Results Mean 30-minute OBPM readings were 7.6/2.5 mmHg (95% confidence interval [CI] = 6.1 to 9.1/1.5 to 3.4 mmHg) lower than standardised OBPM readings. The mean difference and SDD between repeated 30-minute OBPMs (mean difference = 3/1 mmHg, 95% CI = 1 to 5/0 to 2 mmHg; SDD 9.5/5.3 mmHg) were lower than those of standardised OBPMs (mean difference = 6/2 mmHg, 95% CI = 4 to 8/1 to 4 mmHg; SDD 10.9/6.3 mmHg). Conclusion Thirty-minute OBPM resulted in lower readings than standardised OBPM and had a better repeatability. These results suggest that 30-minute OBPM better reflects the patient's true blood pressure than standardised OBPM does. PMID:22152748
Silva, Andréa de Albuquerque Arruda; Coutinho, Isabela C; Katz, Leila; Souza, Alex Sandro Rolland
2013-03-01
Repeat teen pregnancy is a frequent issue and is considered an aggravating factor for increased maternal and fetal morbidity and social problems. The aim of the study was to identify factors associated with repeat teen pregnancy. A case-control study was conducted in 90 postpartum adolescents with more than one pregnancy (cases) and 90 adult women with a history of only one pregnancy during adolescence (controls). Statistical analysis used hierarchical logistic regression with 5% significance. Early sexual initiation (< 15 years), early age at first pregnancy (< 16 years), not raising the children themselves, and low family income (< one minimum wage) were associated with repeat teenage pregnancy, while partner change was inversely associated. Repeat teen pregnancy was mainly associated with reproductive and socioeconomic factors. Partner change appeared as a protective factor. Measures should be adopted during the postpartum period of teenage mothers in order to avoid repeat pregnancy.
ANALYSES OF NEUROBEHAVIORAL SCREENING DATA: BENCHMARK DOSE ESTIMATION.
Analysis of neurotoxicological screening data such as those of the functional observational battery (FOB) traditionally relies on analysis of variance (ANOVA) with repeated measurements, followed by determination of a no-adverse-effect level (NOAEL). The US EPA has proposed the ...
A study on the trinucleotide repeat associated with Huntington`s disease in the Chinese
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bing-wen Soong; Jih-tsuu Wang
1994-09-01
Analysis of the polymorphic (CAG)n repeat in the hungingtin gene in the chinese confirmed the presence of an expanded repeat on all Huntington`s disease chromosomes. Measurement of the specific CAG repeat sequence in 34 HD chromosomes from 15 unrelated families and 190 control chromosomes from the Chinese population showed a range from 9 to 29 repeats in normal subjects and 40 to 58 in affected subjects. The size distributions of normal and affected alleles did not overlap. A clear correlation bewteen early onset of symptoms and very high repeat number was seen, but the spread of the age-at-onset in themore » major repeat range producing characteristic HD it too wide to be of diagnostic value. There was also variability in the transmitted repeat size for both sexes in the HD size range. Maternal HD alleles showed a moderate instability with a preponderance of size decrease, while paternal HD alleles had a tendency to increase in repeat size on transmission, the degree of which appeared proportional to the initial size.« less
The effects of a multi-axis balance board intervention program in an elderly population.
Dougherty, John; Kancel, Anne; Ramar, Cassandra; Meacham, Crystal; Derrington, Stephen
2011-01-01
Balance is a major issue facing the geriatric population. Nine participants from a local community center for seniors completed a five-week study to assess improvement in balance. Measures of balance, performance times, and scores on the Berg Balance Scale (BBS) and the Wii Fit Age (WFA) were recorded before and after the entire intervention. An analysis of variance (ANOVA) with repeated measures was used to assess change in BBS and WFA scores. An analysis of covariance with repeated measures was used to asses the impact of possible contributing factors of age, gender, BMI and total balance board training time over the five-week period. The analysis indicated that use of the Indo Balance Board three times a week for ten minutes can significantly improve balance and potentially decrease the risk of falls, as measured by the BBS. Age was the only factor that significantly influenced balance (p = .006). These improvements are postulated to be due to an increase in subjects' core and lower extremity muscle strength and improved proprioception; a result of balance board usage.
Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret
2017-05-24
Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.
"I Don't Know" and Multiple Choice Analysis of Pre- and Post-Tests
ERIC Educational Resources Information Center
Spears, Karen; Wilson, Mary
2010-01-01
Evaluation is an essential component of any Extension education program. One tool, the pre- and post-test, provides measurable evaluation data. Yet often the answer "I don't know" or all possible answers to a multiple choice question are not included in the repeated measure analysis. Because more than two answers are offered, the test of marginal…
Paul L. Patterson; Renee A. O' Brien
2011-01-01
The Interior West Forest Inventory and Analysis (IW-FIA) program of the USDA Forest Service collects field data on understory vegetation structure that have broad applications. In IW-FIA one aspect of quality assurance is assessed based on the repeatability of field measurements. The understory vegetation protocol consists of two suites of measurements; (1) the...
The overuse of the implant motor: effect on the output torque in overloading condition.
Lee, Du-Hyeong; Cho, Sung-Am; Lee, Cheong-Hee; Lee, Kyu-Bok
2015-06-01
The overloading of the motor affects its performance. The output torque of the implant motor under overloading condition has not been reported. The purpose of this study was to determine the reliability and the tendency of the output torque when an implant motor is consecutively used. Three implant motors were evaluated: SurgicXT/X-SG20L (NSK), INTRAsurg300/CL3-09 (KaVo), and XIP10/CRB26LX (Saeshin). The output torque was measured using an electronic torque gauge fixed with jigs. For the 40 and 50 Ncm torque settings, 300 measurements were taken at 30 rpm. Repeated measures of analysis of variance (ANOVA) and one-way ANOVA were used to compare the torque values within each group and between the groups. As repeating measures, the output torque values decreased gradually compared with the baseline. In within-group analysis, the different torque value from the first measurement appeared earliest in NSK motor, followed in order by Saeshin and KaVo motors. NSK motor showed a different torque decrease between 40 and 50 Ncm settings (p < .05). Intergroup analysis revealed Saeshin motor to have the least deviation from the baseline, followed by KaVo motor. NSK motor had the most inconsistent torque at the 6, 8, 9, and 10 repeat counts (p < .05). The actual torque decreases when the surgical motor is continuously used. The NSK motor showed more significant decreases in torque than KaVo and Saeshin motors in overloading condition. © 2014 Wiley Periodicals, Inc.
Joint modelling of repeated measurement and time-to-event data: an introductory tutorial.
Asar, Özgür; Ritchie, James; Kalra, Philip A; Diggle, Peter J
2015-02-01
The term 'joint modelling' is used in the statistical literature to refer to methods for simultaneously analysing longitudinal measurement outcomes, also called repeated measurement data, and time-to-event outcomes, also called survival data. A typical example from nephrology is a study in which the data from each participant consist of repeated estimated glomerular filtration rate (eGFR) measurements and time to initiation of renal replacement therapy (RRT). Joint models typically combine linear mixed effects models for repeated measurements and Cox models for censored survival outcomes. Our aim in this paper is to present an introductory tutorial on joint modelling methods, with a case study in nephrology. We describe the development of the joint modelling framework and compare the results with those obtained by the more widely used approaches of conducting separate analyses of the repeated measurements and survival times based on a linear mixed effects model and a Cox model, respectively. Our case study concerns a data set from the Chronic Renal Insufficiency Standards Implementation Study (CRISIS). We also provide details of our open-source software implementation to allow others to replicate and/or modify our analysis. The results for the conventional linear mixed effects model and the longitudinal component of the joint models were found to be similar. However, there were considerable differences between the results for the Cox model with time-varying covariate and the time-to-event component of the joint model. For example, the relationship between kidney function as measured by eGFR and the hazard for initiation of RRT was significantly underestimated by the Cox model that treats eGFR as a time-varying covariate, because the Cox model does not take measurement error in eGFR into account. Joint models should be preferred for simultaneous analyses of repeated measurement and survival data, especially when the former is measured with error and the association between the underlying error-free measurement process and the hazard for survival is of scientific interest. © The Author 2015; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.
Yang, Xiaowei; Nie, Kun
2008-03-15
Longitudinal data sets in biomedical research often consist of large numbers of repeated measures. In many cases, the trajectories do not look globally linear or polynomial, making it difficult to summarize the data or test hypotheses using standard longitudinal data analysis based on various linear models. An alternative approach is to apply the approaches of functional data analysis, which directly target the continuous nonlinear curves underlying discretely sampled repeated measures. For the purposes of data exploration, many functional data analysis strategies have been developed based on various schemes of smoothing, but fewer options are available for making causal inferences regarding predictor-outcome relationships, a common task seen in hypothesis-driven medical studies. To compare groups of curves, two testing strategies with good power have been proposed for high-dimensional analysis of variance: the Fourier-based adaptive Neyman test and the wavelet-based thresholding test. Using a smoking cessation clinical trial data set, this paper demonstrates how to extend the strategies for hypothesis testing into the framework of functional linear regression models (FLRMs) with continuous functional responses and categorical or continuous scalar predictors. The analysis procedure consists of three steps: first, apply the Fourier or wavelet transform to the original repeated measures; then fit a multivariate linear model in the transformed domain; and finally, test the regression coefficients using either adaptive Neyman or thresholding statistics. Since a FLRM can be viewed as a natural extension of the traditional multiple linear regression model, the development of this model and computational tools should enhance the capacity of medical statistics for longitudinal data.
Paths to tobacco abstinence: A repeated-measures latent class analysis.
McCarthy, Danielle E; Ebssa, Lemma; Witkiewitz, Katie; Shiffman, Saul
2015-08-01
Knowledge of smoking change processes may be enhanced by identifying pathways to stable abstinence. We sought to identify latent classes of smokers based on their day-to-day smoking status in the first weeks of a cessation attempt. We examined treatment effects on class membership and compared classes on baseline individual differences and 6-month abstinence rates. In this secondary analysis of a double-blind randomized placebo-controlled clinical trial (N = 1,433) of 5 smoking cessation pharmacotherapies (nicotine patch, nicotine lozenge, bupropion SR, patch and lozenge, or bupropion SR and lozenge), we conducted repeated-measures latent class analysis of daily smoking status (any smoking vs. none) for the first 27 days of a quit attempt. Treatment and covariate relations with latent class membership were examined. Distal outcome analysis compared confirmed 6-month abstinence rates among the latent classes. A 5-class solution was selected. Three-quarters of smokers were in stable smoking or abstinent classes, but 25% were in classes with unstable abstinence probabilities over time. Active treatment (compared to placebo), and particularly the patch and lozenge combination, promoted early quitting. Latent classes differed in 6-month abstinence rates and on several baseline variables, including nicotine dependence, quitting history, self-efficacy, sleep disturbance, and minority status. Repeated-measures latent class analysis identified latent classes of smoking change patterns affected by treatment, related to known risk factors, and predictive of distal outcomes. Tracking behavior early in a change attempt may identify prognostic patterns of change and facilitate adaptive treatment planning. (c) 2015 APA, all rights reserved).
Simulated Keratometry Repeatability in Subjects with & without Down Syndrome
Ravikumar, Ayeswarya; Marsack, Jason D.; Benoit, Julia S.; Anderson, Heather A.
2016-01-01
Purpose To assess the repeatability of simulated keratometry measures obtained with Zeiss Atlas topography for subjects with and without Down syndrome (DS). Methods Corneal topography was attempted on 140 subjects with DS and 138 controls (aged 7 to 59 years). Subjects who had at least 3 measures in each eye were included in analysis (DS: n=140 eyes (70 subjects) and controls: n=264 eyes (132 subjects)). For each measurement the steep corneal power (K), corneal astigmatism, flat K orientation, power vector representation of astigmatism (J0, J45), and astigmatic dioptric difference were determined for each measurement (collectively termed keratometry values here). For flat K orientation comparisons, only eyes with >0.50 DC of astigmatism were included (DS: n=131 eyes (68 subjects) and control: n=217 eyes (119 subjects)). Repeatability was assessed using 1) group mean variability (average standard deviation (SD) across subjects), 2) coefficient of repeatability (COR) 3) coefficient of variation (COV), and 4) intraclass correlation coefficient (ICC). Results The keratometry values showed good repeatability as evidenced by low group mean variability for DS vs control eyes (≤0.26D vs ≤0.09D for all dioptric values; 4.51° vs 3.16° for flat K orientation); however, the group mean variability was significantly higher in DS eyes than control eyes for all parameters (p≤0.03). On average, group mean variability was 2.5× greater in the DS eyes compared to control eyes across the keratometry values. Other metrics of repeatability also indicated good repeatability for both populations for each keratometry value, although repeatability was always better in the control eyes. Conclusions DS eyes showed more variability (on average: 2.5×) compared to controls for all keratometry values. Although differences were statistically significant, on average 91% of DS eyes had variability ≤0.50D for steep K and astigmatism, and 75% of DS eyes had variability ≤5 degrees for flat K orientation. PMID:27741083
Characterization of Upper Eyelid Tarsus and Lid Wiper Dimensions.
Navascues-Cornago, Maria; Maldonado-Codina, Carole; Gupta, Ruchi; Morgan, Philip B
2016-09-01
To measure various dimensions of the upper tarsal plate and the area of upper lid wiper staining. The repeatability of the method of measurement was investigated. Thirty-five healthy non-contact lens wearers were enrolled. The following parameters were measured from digital images of the upper eyelid captured with a slitlamp camera: length, height, and total area of the tarsal plate and area of lid wiper staining (lissamine green). Measurements were performed in a randomized and masked fashion on two separate occasions by the same investigator using ImageJ (National Institutes of Health). Coefficients of repeatability (COR) were calculated. The dimensions (mean±SD) of the tarsal plate were 20.6±1.9 mm length, 7.9±0.8 mm height, and 103.3±18.8 mm total area. The area of lid wiper staining was 2.7±2.0 mm. No association was found between tarsal dimensions and lid wiper staining (all P>0.05). Image analysis COR values were 0.6 mm tarsal length, 0.1 mm tarsal height, 1.2 mm tarsal area, and 0.4 mm lid wiper staining. There was no significant difference between repeated measurements for any parameter (all P>0.05). Limits of agreement were narrow for all parameters, indicating good agreement between repeated measurements. This work has demonstrated that there is a wide range in the dimensions of the upper tarsal plate in an urban UK population. No association was found between the upper tarsal dimensions and lid wiper staining. ImageJ was shown to be a repeatable method to measure the dimensions of the upper tarsal plate and upper lid wiper staining.
Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi
2016-07-30
We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55-75) with a BMI ≥27 and <40 kg/m², and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student's t-test comparisons. A total of 160 participants were included in the analysis. The Bland-Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of -0.65 and 0.22, respectively (R² = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability.
Wang, Qing-qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
Objective This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. Method A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Result Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Conclusion Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research. PMID:29049323
Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li
2017-01-01
This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.
Coppard, Nicholas; Cooper, Jonathon M.; Delatycki, Martin B.; Dürr, Alexandra; Di Prospero, Nicholas A.; Giunti, Paola; Lynch, David R.; Schulz, J. B.; Rummey, Christian; Meier, Thomas
2013-01-01
The aim of this cross-sectional study was to analyse disease progression in Friedreich’s ataxia as measured by the International Cooperative Ataxia Rating Scale. Single ratings from 603 patients with Friedreich’s ataxia were analysed as a function of disease duration, age of onset and GAA repeat lengths. The relative contribution of items and subscales to the total score was studied as a function of disease progression. In addition, the scaling properties were assessed using standard statistical measures. Average total scale progression per year depends on the age of disease onset, the time since diagnosis and the GAA repeat length. The age of onset inversely correlates with increased GAA repeat length. For patients with an age of onset ≤14 years associated with a longer repeat length, the average yearly rate of decline was 2.5 ± 0.18 points in the total International Cooperative Ataxia Rating Scale for the first 20 years of disease duration, whereas patients with a later onset progress more slowly (1.8 ± 0.27 points/year). Ceiling effects in posture, gait and lower limb scale items lead to a reduced sensitivity of the scale in the severely affected population with a total score of >60 points. Psychometric scaling analysis shows generally favourable properties for the total scale, but the subscale grouping could be improved. This cross-sectional study provides a detailed characterization of the International Cooperative Ataxia Rating Scale. The analysis further provides rates of change separated for patients with early and late disease onset, which is driven by the GAA repeat length. Differences in the subscale dynamics merit consideration in the design of future clinical trials applying this scale as a neurological assessment instrument in Friedreich’s ataxia. PMID:23365101
[Review of research design and statistical methods in Chinese Journal of Cardiology].
Zhang, Li-jun; Yu, Jin-ming
2009-07-01
To evaluate the research design and the use of statistical methods in Chinese Journal of Cardiology. Peer through the research design and statistical methods in all of the original papers in Chinese Journal of Cardiology from December 2007 to November 2008. The most frequently used research designs are cross-sectional design (34%), prospective design (21%) and experimental design (25%). In all of the articles, 49 (25%) use wrong statistical methods, 29 (15%) lack some sort of statistic analysis, 23 (12%) have inconsistencies in description of methods. There are significant differences between different statistical methods (P < 0.001). The correction rates of multifactor analysis were low and repeated measurement datas were not used repeated measurement analysis. Many problems exist in Chinese Journal of Cardiology. Better research design and correct use of statistical methods are still needed. More strict review by statistician and epidemiologist is also required to improve the literature qualities.
Herold, Ingeborg H F; Saporito, Salvatore; Bouwman, R Arthur; Houthuizen, Patrick; van Assen, Hans C; Mischi, Massimo; Korsten, Hendrikus H M
2016-01-05
The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.
Repeatability analysis of the K. J. Law Model 8300 Roughness Surveyor : final report.
DOT National Transportation Integrated Search
1991-04-01
The K.J. Law Model 8300 Roughness surveyor, is a ride-quality measurement device used to determine and analyze the longitudinal roadway profile. This paper describes an analysis of IRI data as collected with Louisiana's Roughness Surveyor to determin...
Bootstrap Standard Error Estimates in Dynamic Factor Analysis
ERIC Educational Resources Information Center
Zhang, Guangjian; Browne, Michael W.
2010-01-01
Dynamic factor analysis summarizes changes in scores on a battery of manifest variables over repeated measurements in terms of a time series in a substantially smaller number of latent factors. Algebraic formulae for standard errors of parameter estimates are more difficult to obtain than in the usual intersubject factor analysis because of the…
Configural Frequency Analysis as a Statistical Tool for Developmental Research.
ERIC Educational Resources Information Center
Lienert, Gustav A.; Oeveste, Hans Zur
1985-01-01
Configural frequency analysis (CFA) is suggested as a technique for longitudinal research in developmental psychology. Stability and change in answers to multiple choice and yes-no item patterns obtained with repeated measurements are identified by CFA and illustrated by developmental analysis of an item from Gorham's Proverb Test. (Author/DWH)
High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices.
Harrar, Solomon W; Kong, Xiaoli
2015-03-01
In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results.
High-Dimensional Multivariate Repeated Measures Analysis with Unequal Covariance Matrices
Harrar, Solomon W.; Kong, Xiaoli
2015-01-01
In this paper, test statistics for repeated measures design are introduced when the dimension is large. By large dimension is meant the number of repeated measures and the total sample size grow together but either one could be larger than the other. Asymptotic distribution of the statistics are derived for the equal as well as unequal covariance cases in the balanced as well as unbalanced cases. The asymptotic framework considered requires proportional growth of the sample sizes and the dimension of the repeated measures in the unequal covariance case. In the equal covariance case, one can grow at much faster rate than the other. The derivations of the asymptotic distributions mimic that of Central Limit Theorem with some important peculiarities addressed with sufficient rigor. Consistent and unbiased estimators of the asymptotic variances, which make efficient use of all the observations, are also derived. Simulation study provides favorable evidence for the accuracy of the asymptotic approximation under the null hypothesis. Power simulations have shown that the new methods have comparable power with a popular method known to work well in low-dimensional situation but the new methods have shown enormous advantage when the dimension is large. Data from Electroencephalograph (EEG) experiment is analyzed to illustrate the application of the results. PMID:26778861
McFarquhar, Martyn; McKie, Shane; Emsley, Richard; Suckling, John; Elliott, Rebecca; Williams, Stephen
2016-01-01
Repeated measurements and multimodal data are common in neuroimaging research. Despite this, conventional approaches to group level analysis ignore these repeated measurements in favour of multiple between-subject models using contrasts of interest. This approach has a number of drawbacks as certain designs and comparisons of interest are either not possible or complex to implement. Unfortunately, even when attempting to analyse group level data within a repeated-measures framework, the methods implemented in popular software packages make potentially unrealistic assumptions about the covariance structure across the brain. In this paper, we describe how this issue can be addressed in a simple and efficient manner using the multivariate form of the familiar general linear model (GLM), as implemented in a new MATLAB toolbox. This multivariate framework is discussed, paying particular attention to methods of inference by permutation. Comparisons with existing approaches and software packages for dependent group-level neuroimaging data are made. We also demonstrate how this method is easily adapted for dependency at the group level when multiple modalities of imaging are collected from the same individuals. Follow-up of these multimodal models using linear discriminant functions (LDA) is also discussed, with applications to future studies wishing to integrate multiple scanning techniques into investigating populations of interest. PMID:26921716
Lipp, Ilona; Murphy, Kevin; Caseras, Xavier; Wise, Richard G
2015-06-01
FMRI BOLD responses to changes in neural activity are influenced by the reactivity of the vasculature. By complementing a task-related BOLD acquisition with a vascular reactivity measure obtained through breath-holding or hypercapnia, this unwanted variance can be statistically reduced in the BOLD responses of interest. Recently, it has been suggested that vascular reactivity can also be estimated using a resting state scan. This study aimed to compare three breath-hold based analysis approaches (block design, sine-cosine regressor and CO2 regressor) and a resting state approach (CO2 regressor) to measure vascular reactivity. We tested BOLD variance explained by the model and repeatability of the measures. Fifteen healthy participants underwent a breath-hold task and a resting state scan with end-tidal CO2 being recorded during both. Vascular reactivity was defined as CO2-related BOLD percent signal change/mmHg change in CO2. Maps and regional vascular reactivity estimates showed high repeatability when the breath-hold task was used. Repeatability and variance explained by the CO2 trace regressor were lower for the resting state data based approach, which resulted in highly variable measures of vascular reactivity. We conclude that breath-hold based vascular reactivity estimations are more repeatable than resting-based estimates, and that there are limitations with replacing breath-hold scans by resting state scans for vascular reactivity assessment. Copyright © 2015. Published by Elsevier Inc.
Lipp, Ilona; Murphy, Kevin; Caseras, Xavier; Wise, Richard G.
2015-01-01
FMRI BOLD responses to changes in neural activity are influenced by the reactivity of the vasculature. By complementing a task-related BOLD acquisition with a vascular reactivity measure obtained through breath-holding or hypercapnia, this unwanted variance can be statistically reduced in the BOLD responses of interest. Recently, it has been suggested that vascular reactivity can also be estimated using a resting state scan. This study aimed to compare three breath-hold based analysis approaches (block design, sine–cosine regressor and CO2 regressor) and a resting state approach (CO2 regressor) to measure vascular reactivity. We tested BOLD variance explained by the model and repeatability of the measures. Fifteen healthy participants underwent a breath-hold task and a resting state scan with end-tidal CO2 being recorded during both. Vascular reactivity was defined as CO2-related BOLD percent signal change/mm Hg change in CO2. Maps and regional vascular reactivity estimates showed high repeatability when the breath-hold task was used. Repeatability and variance explained by the CO2 trace regressor were lower for the resting state data based approach, which resulted in highly variable measures of vascular reactivity. We conclude that breath-hold based vascular reactivity estimations are more repeatable than resting-based estimates, and that there are limitations with replacing breath-hold scans by resting state scans for vascular reactivity assessment. PMID:25795342
Ding, Xiaohu; Huang, Qunxiao; Zheng, Yingfeng; Jiang, Yuzhen; Huang, Shengsong; He, Mingguang
2012-10-01
To investigate the repeatability of the semiautomatic assessment of corneal endothelial cells and its association with the measurement area in the Topcon SP-2000P microscope and IMAGEnet system. Specular microscopic images of 86 healthy subjects were captured and analyzed using the Topcon SP-2000P microscope and IMAGEnet system. The same images were analyzed twice, on separate days, by the same examiner using the built-in measurement tool of the IMAGEnet system. The measurement areas were defined with a frame mounted on a computer screen. Four different-sized measurement areas were chosen for the semiautomatic measurements: box A (5.4 × 13.9 cm(2)), box B (4 × 10 cm(2)), box C (4 × 7 cm(2)), and box D (2 × 5 cm(2)). Average cell size (ACS), endothelial cell density (ECD), coefficient of variance, and hexagonality were measured. Repeatability was assessed based on the limit of agreement (LOA). The means of ACS, ECD, and hexagonality were not statistically different across 4 measurement areas (analysis of variance, P > 0.05). The mean differences (bias) were modest for ACS (range, -1.9∼3.9 μm(2)), ECD (range, -27.2∼14.6 cells per square millimeter), coefficient of variance (range, -0.14∼1.00), and hexagonality (range, -1.3%∼6.8%). Limits of agreement (mean difference ± 1.96× SD) were greater in the measurements with smaller areas: limit of agreement values for ECD were 14.6 ± 99.6, -3.8 ± 101.1, -27.2 ± 179, and -15.8 ± 488 cells per square millimeter for boxes A, B, C, and D, respectively. Similar trends were found in the repeatability of ACS and hexagonality. Repeatability is improved when larger measurement areas are chosen.
Linear Array Ultrasonic Testing Of A Thick Concrete Specimens For Non-Destructive Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clayton, Dwight A.; Khazanovich, Lev; Zammerachi, Mattia
The University of Minnesota and Oak Ridge National Laboratory are collaborating on the design and construction of a concrete specimen with sufficient reinforcement density and cross-sectional size to represent a light water reactor (LWR) containment wall with various defects. The preliminary analysis of the collected data using extended synthetic aperture focussin technique (SAFT) reconstruction indicated a great potential of the ultrasound array technology for locating relatively shallow distresses. However, the resolution and reliability of the analysis is inversely proportional to the defect depth and the amount of reinforcement between the measurement point and the defect location. The objective of thismore » round of testing is to evaluate repeatability of the obtained reconstructions from measurements with different frequencies as well as to examine the effect of the duration of the sending ultrasound signal on the resulting reconstructions. Two series of testing are performed in this study. The objective of the first series is to evaluate repeatability of the measurements and resulting reconstructed images. The measurements use three center frequencies. Five measurements are performed at each location with and without lifting the device. The analysis of the collected data suggested that a linear array ultrasound system can produce reliably repeatable reconstructions using 50 kHz signals for relatively shallow depths (less than 0.5 m). However, for reconstructions at the greater depths the use of lower frequency and/or signal filtering to reduce the effect of signal noise may be required. The objective of the second series of testing is to obtain measurements with various impulse signal durations. The entire grid on the smooth surface is tested with four different various impulse signal durations. An analysis of the resulting extended SAFT reconstructions suggested that Kirchhoff-based migration leads to easier interpreting reconstructions when shorter duration impulse is used. Longer duration impulses may provide useful information for model-based reconstructions.« less
Heijmen, Linda; de Geus-Oei, Lioe-Fee; de Wilt, Johannes H W; Visvikis, Dimitris; Hatt, Mathieu; Visser, Eric P; Bussink, Johan; Punt, Cornelis J A; Oyen, Wim J G; van Laarhoven, Hanneke W M
2012-12-01
Several studies showed potential for monitoring response to systemic therapy in metastatic colorectal cancer patients with (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Before (18)F-FDG PET can be implemented for response evaluation the repeatability should be known. This study was performed to assess the magnitude of the changes in standardized uptake value (SUV), volume and total lesion glycolysis (TLG) in colorectal liver metastases and validate the biological basis of (18)F-FDG PET in colorectal liver metastases. Twenty patients scheduled for liver metastasectomy underwent two (18)F-FDG PET scans within 1 week. Bland-Altman analysis was performed to assess repeatability of SUV(max), SUV(mean), volume and TLG. Tumours were delineated using an adaptive threshold method (PET(SBR)) and a semiautomatic fuzzy locally adaptive Bayesian (FLAB) delineation method. Coefficient of repeatability of SUV(max) and SUV(mean) were ∼39 and ∼31 %, respectively, independent of the delineation method used and image reconstruction parameters. However, repeatability was worse in recently treated patients. The FLAB delineation method improved the repeatability of the volume and TLG measurements compared to PET(SBR), from coefficients of repeatability of over 85 % to 45 % and 57 % for volume and TLG, respectively. Glucose transporter 1 (GLUT1) expression correlated to the SUV(mean). Vascularity (CD34 expression) and tumour hypoxia (carbonic anhydrase IX expression) did not correlate with (18)F-FDG PET parameters. In conclusion, repeatability of SUV(mean) and SUV(max) was mainly affected by preceding systemic therapy. The repeatability of tumour volume and TLG could be improved using more advanced and robust delineation approaches such as FLAB, which is recommended when (18)F-FDG PET is utilized for volume or TLG measurements. Improvement of repeatability of PET measurements, for instance by dynamic PET scanning protocols, is probably necessary to effectively use PET for early response monitoring.
Ribeiro, Daniel Cury; de Castro, Marcelo Peduzzi; Sole, Gisela; Vicenzino, Bill
2016-04-01
Manual therapy enhances pain-free range of motion and reduces pain levels, but its effect on shoulder muscle activity is unclear. This study aimed to assess the effects of a sustained glenohumeral postero-lateral glide during elevation on shoulder muscle activity. Thirty asymptomatic individuals participated in a repeated measures study of the electromyographic activity of the supraspinatus, infraspinatus, posterior deltoid, and middle deltoid. Participants performed four sets of 10 repetitions of shoulder scaption and abduction with and without a glide of the glenohumeral joint. Repeated-measures multivariate analysis of variance (MANOVA) was used to assess the effects of movement direction (scaption and abduction), and condition (with and without glide) (within-subject factors) on activity level of each muscle (dependent variables). Significant MANOVAs were followed-up with repeated-measures one-way analysis of variance. During shoulder scaption with glide, the supraspinatus showed a reduction of 4.1% maximal isometric voluntary contraction (MVIC) (95% CI 2.4, 5.8); and infraspinatus 1.3% MVIC (95% CI 0.5, 2.1). During shoulder abduction with a glide, supraspinatus presented a reduction of 2.5% MVIC (95% CI 1.1, 4.0), infraspinatus 2.1% MVIC (95% CI 1.0, 3.2), middle deltoid 2.2% MVIC (95% CI = 0.4, 4.1), posterior deltoid 2.1% MVIC (95% CI 1.3, 2.8). In asymptomatic individuals, sustained glide reduced shoulder muscle activity compared to control conditions. This might be useful in enhancing shoulder movement in clinical populations. Reductions in muscle activity might result from altered joint mechanics, including simply helping to lift the arm, and/or through changing afferent sensory input about the shoulder. Copyright © 2015 Elsevier Ltd. All rights reserved.
How do repeat suicide attempters differ from first timers? An exploratory record based analysis
Menon, Vikas; Kattimani, Shivanand; Sarkar, Siddharth; Mathan, Kaliaperumal
2016-01-01
Background: Evidence indicates that repeat suicide attempters, as a group, may differ from 1st time attempters. The identification of repeat attempters is a powerful but underutilized clinical variable. Aims: In this research, we aimed to compare individuals with lifetime histories of multiple attempts with 1st time attempters to identify factors predictive of repeat attempts. Setting and Design: This was a retrospective record based study carried out at a teaching cum Tertiary Care Hospital in South India. Methods: Relevant data was extracted from the clinical records of 1st time attempters (n = 362) and repeat attempters (n = 61) presenting to a single Tertiary Care Center over a 4½ year period. They were compared on various sociodemographic and clinical parameters. The clinical measures included Presumptive Stressful Life Events Scale, Beck Hopelessness Scale, Coping Strategies Inventory – Short Form, and the Global Assessment of Functioning Scale. Statistical Analysis Used: First time attempters and repeaters were compared using appropriate inferential statistics. Logistic regression was used to identify independent predictors of repeat attempts. Results: The two groups did not significantly differ on sociodemographic characteristics. Repeat attempters were more likely to have given prior hints about their act (χ2 = 4.500, P = 0.034). In the final regression model, beck hopelessness score emerged as a significant predictor of repeat suicide attempts (odds ratio = 1.064, P = 0.020). Conclusion: Among suicide attempters presenting to the hospital, the presence of hopelessness is a predictor of repeat suicide attempts, independent of clinical depression. This highlights the importance of considering hopelessness in the assessment of suicidality with a view to minimize the risk of future attempts. PMID:26933353
Garcia-Martin, Elena; Rodriguez-Mena, Diego; Dolz, Isabel; Almarcegui, Carmen; Gil-Arribas, Laura; Bambo, Maria P; Larrosa, Jose M; Polo, Vicente; Pablo, Luis E
2013-08-01
To evaluate the effect of uncomplicated cataract phacoemulsification on the measurements of visual evoked potentials (VEP), pattern electroretinogram (PERG), and macular and retinal nerve fiber layer (RNFL) using 2 spectral-domain optical coherence tomography (OCT) instruments, the Cirrus OCT (Carl Zeiss Meditech) and Spectralis OCT (Heidelberg Engineering), in patients with retinitis pigmentosa (RP), and to assess the reliability of the OCT measurements before and after cataract surgery. Observational cross-sectional study. Thirty-five eyes of 35 patients with RP (20 men and 15 women, 45-66 years) who underwent cataract phacoemulsification were studied. At 1 month before and 1 month after surgery, visual acuity, VEP, PERG, and 3 repetitions of scans using the RNFL and macular analysis protocols of the Cirrus and Spectralis OCT instruments were performed. The differences in measurements between the 2 visits were analyzed. Repeatability of OCT measurements was evaluated by calculating the coefficients of variation. VEP amplitude, RNFL thicknesses provided by Cirrus and Spectralis, and macular measurements provided by Cirrus OCT differed between the 2 visits. VEP latency, PERG measurements, and macular thicknesses provided by the Spectralis OCT before surgery did not differ significantly from those after surgery. The OCT repeatability was better after surgery, with lower coefficients of variation for scans performed after surgical removal of the cataract. The nuclear, cortical, and posterior subcapsular types of cataracts did not show different repeatability. The presence of cataracts affects VEP amplitude, RNFL, and macular measurements performed with OCT in eyes with RP. Image repeatability significantly improves after cataract phacoemulsification. Copyright © 2013 Elsevier Inc. All rights reserved.
The impact of response measurement error on the analysis of designed experiments
Anderson-Cook, Christine Michaela; Hamada, Michael Scott; Burr, Thomas Lee
2016-11-01
This study considers the analysis of designed experiments when there is measurement error in the true response or so-called response measurement error. We consider both additive and multiplicative response measurement errors. Through a simulation study, we investigate the impact of ignoring the response measurement error in the analysis, that is, by using a standard analysis based on t-tests. In addition, we examine the role of repeat measurements in improving the quality of estimation and prediction in the presence of response measurement error. We also study a Bayesian approach that accounts for the response measurement error directly through the specification ofmore » the model, and allows including additional information about variability in the analysis. We consider the impact on power, prediction, and optimization. Copyright © 2015 John Wiley & Sons, Ltd.« less
The impact of response measurement error on the analysis of designed experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson-Cook, Christine Michaela; Hamada, Michael Scott; Burr, Thomas Lee
This study considers the analysis of designed experiments when there is measurement error in the true response or so-called response measurement error. We consider both additive and multiplicative response measurement errors. Through a simulation study, we investigate the impact of ignoring the response measurement error in the analysis, that is, by using a standard analysis based on t-tests. In addition, we examine the role of repeat measurements in improving the quality of estimation and prediction in the presence of response measurement error. We also study a Bayesian approach that accounts for the response measurement error directly through the specification ofmore » the model, and allows including additional information about variability in the analysis. We consider the impact on power, prediction, and optimization. Copyright © 2015 John Wiley & Sons, Ltd.« less
Effect of repeated earthquake on inelastic moment resisting concrete frame
NASA Astrophysics Data System (ADS)
Tahara, R. M. K.; Majid, T. A.; Zaini, S. S.; Faisal, A.
2017-10-01
This paper investigates the response of inelastic moment resisting concrete building under repeated earthquakes. 2D models consist of 3-storey, 6-storey and 9-storey representing low to medium rise building frame were designed using seismic load and ductility class medium (DCM) according to the requirements set by Euro Code 8. Behaviour factor and stiffness degradation were also taken into consideration. Seven sets of real repeated earthquakes as opposed to artificial earthquakes data were used. The response of the frame was measured in terms of the inter-storey drift and maximum displacement. By adopting repeated earthquake, the recorded mean IDR increased in the range of 3% - 21%. Similarly, in the case of maximum displacement, the values also increased from 20 mm to 40 mm. The findings concluded that the effect of using repeated earthquake in seismic analysis considerably influenced the inter-storey drift and the maximum displacement.
An electronic nose for reliable measurement and correct classification of beverages.
Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A
2011-01-01
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.
An Electronic Nose for Reliable Measurement and Correct Classification of Beverages
Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A.
2011-01-01
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results. PMID:22163964
NASA Astrophysics Data System (ADS)
Bruns, Donald
2016-05-01
In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.
Leasure, Jessica O; Peck, Jeffrey N; Villamil, Armando; Fiore, Kara L; Tano, Cheryl A
2016-11-23
To evaluate the inter- and intra-observer variability in measurement of the angle of lateral opening (ALO) and version angle measurement using digital radiography and computed tomography (CT). Each hemipelvis was implanted with a cementless acetabular cup. Ventrodorsal and mediolateral radiographs were made of each pelvis, followed by CT imaging. After removal of the first cup, the pelves were implanted with an acetabular cup in the contralateral acetabulum and imaging was repeated. Three surgeons measured the ALO and version angles three times for each cup from the mediolateral radiographic projection. The same measurements were made using three-dimensional multiplanar reconstructions from CT images. Two anatomical axes were used to measure pelvic inclination in the sagittal plane, resulting in six measurements per cup. Two-way repeated measures analysis of variance evaluated inter- and intra-observer repeatability for radiographic and CT-based measurements. Version angle based on radiographic measurement did not differ within surgeons (p = 0.433), but differed between surgeons (p <0.001). Radiographic measurement of ALO differed within surgeons (p = 0.006) but not between surgeons (p = 0.989). The ALO and version angle measured on CT images did not differ with or between surgeons. Assessment of inter- and intra-observer measurement of ALO and version angle was more reproducible using CT images than conventional mediolateral radiography for a Zurich cementless acetabular cup.
Measuring Intervention Effectiveness: The Benefits of an Item Response Theory Approach
ERIC Educational Resources Information Center
McEldoon, Katherine; Cho, Sun-Joo; Rittle-Johnson, Bethany
2012-01-01
Assessing the effectiveness of educational interventions relies on quantifying differences between interventions groups over time in a between-within design. Binary outcome variables (e.g., correct responses versus incorrect responses) are often assessed. Widespread approaches use percent correct on assessments, and repeated measures analysis of…
Ferragina, A; Cipolat-Gotet, C; Cecchinato, A; Pazzola, M; Dettori, M L; Vacca, G M; Bittante, G
2017-05-01
The aim of this study was to apply Bayesian models to the Fourier-transform infrared spectroscopy spectra of individual sheep milk samples to derive calibration equations to predict traditional and modeled milk coagulation properties (MCP), and to assess the repeatability of MCP measures and their predictions. Data consisted of 1,002 individual milk samples collected from Sarda ewes reared in 22 farms in the region of Sardinia (Italy) for which MCP and modeled curd-firming parameters were available. Two milk samples were taken from 87 ewes and analyzed with the aim of estimating repeatability, whereas a single sample was taken from the other 915 ewes. Therefore, a total of 1,089 analyses were performed. For each sample, 2 spectra in the infrared region 5,011 to 925 cm -1 were available and averaged before data analysis. BayesB models were used to calibrate equations for each of the traits. Prediction accuracy was estimated for each trait and model using 20 replicates of a training-testing validation procedure. The repeatability of MCP measures and their predictions were also compared. The correlations between measured and predicted traits, in the external validation, were always higher than 0.5 (0.88 for rennet coagulation time). We confirmed that the most important element for finding the prediction accuracy is the repeatability of the gold standard analyses used for building calibration equations. Repeatability measures of the predicted traits were generally high (≥95%), even for those traits with moderate analytical repeatability. Our results show that Bayesian models applied to Fourier-transform infrared spectra are powerful tools for cheap and rapid prediction of important traits in ovine milk and, compared with other methods, could help in the interpretation of results. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Minimum number of measurements for evaluating Bertholletia excelsa.
Baldoni, A B; Tonini, H; Tardin, F D; Botelho, S C C; Teodoro, P E
2017-09-27
Repeatability studies on fruit species are of great importance to identify the minimum number of measurements necessary to accurately select superior genotypes. This study aimed to identify the most efficient method to estimate the repeatability coefficient (r) and predict the minimum number of measurements needed for a more accurate evaluation of Brazil nut tree (Bertholletia excelsa) genotypes based on fruit yield. For this, we assessed the number of fruits and dry mass of seeds of 75 Brazil nut genotypes, from native forest, located in the municipality of Itaúba, MT, for 5 years. To better estimate r, four procedures were used: analysis of variance (ANOVA), principal component analysis based on the correlation matrix (CPCOR), principal component analysis based on the phenotypic variance and covariance matrix (CPCOV), and structural analysis based on the correlation matrix (mean r - AECOR). There was a significant effect of genotypes and measurements, which reveals the need to study the minimum number of measurements for selecting superior Brazil nut genotypes for a production increase. Estimates of r by ANOVA were lower than those observed with the principal component methodology and close to AECOR. The CPCOV methodology provided the highest estimate of r, which resulted in a lower number of measurements needed to identify superior Brazil nut genotypes for the number of fruits and dry mass of seeds. Based on this methodology, three measurements are necessary to predict the true value of the Brazil nut genotypes with a minimum accuracy of 85%.
Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A.; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi
2016-01-01
We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55–75) with a BMI ≥27 and <40 kg/m2, and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student’s t-test comparisons. A total of 160 participants were included in the analysis. The Bland–Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of −0.65 and 0.22, respectively (R2 = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability. PMID:27483318
ERIC Educational Resources Information Center
Bejar, Isaac I.
1981-01-01
Effects of nutritional supplementation on physical development of malnourished children was analyzed by univariate and multivariate methods for the analysis of repeated measures. Results showed that the nutritional treatment was successful, but it was necessary to resort to the multivariate approach. (Author/GK)
Analysis of Longitudinal Outcome Data with Missing Values in Total Knee Arthroplasty.
Kang, Yeon Gwi; Lee, Jang Taek; Kang, Jong Yeal; Kim, Ga Hye; Kim, Tae Kyun
2016-01-01
We sought to determine the influence of missing data on the statistical results, and to determine which statistical method is most appropriate for the analysis of longitudinal outcome data of TKA with missing values among repeated measures ANOVA, generalized estimating equation (GEE) and mixed effects model repeated measures (MMRM). Data sets with missing values were generated with different proportion of missing data, sample size and missing-data generation mechanism. Each data set was analyzed with three statistical methods. The influence of missing data was greater with higher proportion of missing data and smaller sample size. MMRM tended to show least changes in the statistics. When missing values were generated by 'missing not at random' mechanism, no statistical methods could fully avoid deviations in the results. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bahreini, M.; Ashrafkhani, B.; Tavassoli, S. H.
2014-03-01
Laser-induced breakdown spectroscopy (LIBS) is applied to investigate the effect of alcoholism and doping on elemental composition of fingernails of subjects. Measurements are made on 36 fingernail clippings including 8 doping, 8 alcoholic and 20 normal subjects. Classification of normal, alcoholic and doping subjects based on 46 atomic and ionic emission lines belonging to 13 elements of fingernail is examined using discriminant function analysis (DFA) method. The most affecting elements in classification of groups are discussed. In order to improve the repeatability of LIBS measurements, an auto-focus system has been designed and used in experiments. Results are promising and show that by improving the repeatability of experiments through improving the setup, some evidence of the impact of the alcohol and doping on elemental composition of fingernails is observed.
151-km single-end phase-sensitive optical time-domain reflectometer assisted by optical repeater
NASA Astrophysics Data System (ADS)
Song, Muping; Zhu, Weiji; Xia, Qiaolan; Yin, Cong; Lu, Yan; Wu, Ying; Zhuang, Shouwang
2018-02-01
A phase-sensitive optical time-domain reflectometry (ϕOTDR) system that can detect intrusion over 150 km is presented. The ϕOTDR system uses nonbalanced optical repeaters to extend the sensing distance. The repeater consists of two erbium-doped optical fiber amplifiers (EDFAs) and one Raman amplifier (RA). One EDFA power amplifier amplifies the forward-transmitting pulse, and one EDFA preamplifier is used for the backscattering signal, respectively. The RA helps keeping the power along the fiber stable. The optical repeater is installed at the connection of two adjacent fibers to compensate the power decline due to fiber loss. It is easy to install the repeater midway among the fiber links in the system for longer-distance sensing since there is no need of modifying the original sensing system. The theoretical analysis of the repeater is given to describe its effect on the distributed sensing. In experiments, several ϕOTDR traces show a good agreement with theoretical results. Using the optical repeater, 35-Hz vibration at 151 km is successfully measured with signal-to-noise ratio of 8 dB without extra signal processing.
Messaraa, C; Metois, A; Walsh, M; Hurley, S; Doyle, L; Mansfield, A; O'Connor, C; Mavon, A
2018-01-24
Skin topographic measurements are of paramount importance in the field of dermo-cosmetic evaluation. The aim of this study was to investigate how the Antera 3D, a multi-purpose handheld camera, correlates with other topographic techniques and changes in skin topography following the use of a cosmetic product. Skin topographic measurements were collected on 26 female volunteers aged 45-70 years with the Antera 3D, the DermaTOP and image analysis on parallel-polarized pictures. Different filters for analysis from the Antera 3D were investigated for repeatability, correlations with other imaging techniques and ability to detect improvements of skin topography following application of a serum. Most of Antera 3D parameters were found to be strongly correlated with the DermaTOP parameters. No association was found between the Antera 3D parameters and measurements on parallel-polarized photographs. The measurements repeatability was comparable among the different filters for analysis, with the exception of wrinkle max depth and roughness Rt. Following a single application of a tightening serum, both Antera 3D wrinkles and texture parameters were able to record significant improvements, with the best improvements observed with the large filter. The Antera 3D demonstrated its relevance for cosmetic product evaluation. We also provide recommendations for the analysis based on our findings. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Reliability of segmental accelerations measured using a new wireless gait analysis system.
Kavanagh, Justin J; Morrison, Steven; James, Daniel A; Barrett, Rod
2006-01-01
The purpose of this study was to determine the inter- and intra-examiner reliability, and stride-to-stride reliability, of an accelerometer-based gait analysis system which measured 3D accelerations of the upper and lower body during self-selected slow, preferred and fast walking speeds. Eight subjects attended two testing sessions in which accelerometers were attached to the head, neck, lower trunk, and right shank. In the initial testing session, two different examiners attached the accelerometers and performed the same testing procedures. A single examiner repeated the procedure in a subsequent testing session. All data were collected using a new wireless gait analysis system, which features near real-time data transmission via a Bluetooth network. Reliability for each testing condition (4 locations, 3 directions, 3 speeds) was quantified using a waveform similarity statistic known as the coefficient of multiple determination (CMD). CMD's ranged from 0.60 to 0.98 across all test conditions and were not significantly different for inter-examiner (0.86), intra-examiner (0.87), and stride-to-stride reliability (0.86). The highest repeatability for the effect of location, direction and walking speed were for the shank segment (0.94), the vertical direction (0.91) and the fast walking speed (0.91), respectively. Overall, these results indicate that a high degree of waveform repeatability was obtained using a new gait system under test-retest conditions involving single and dual examiners. Furthermore, differences in acceleration waveform repeatability associated with the reapplication of accelerometers were small in relation to normal motor variability.
Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana
2018-06-01
To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.
Suitability of open-field autorefractors as pupillometers and instrument design effects.
Otero, Carles; Aldaba, Mikel; Ferrer, Oriol; Gascón, Andrea; Ondategui-Parra, Juan C; Pujol, Jaume
2017-01-01
To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw) and paired t -tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. The mean difference (±standard deviation) between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16), -0.05 (±0.18) and -0.08 (±0.23) mm for Neuroptics, -0.05 (±0.17), -0.12 (±0.23) and -0.17 (±0.34) mm for WAM-5500, -0.04 (±0.27), -0.13 (±0.37) and -0.11 (±0.28) mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35), -0.83 (±0.52) and -0.38 (±0.56) mm for WAM-5500, -0.28 (±0.56), -0.70 (±0.55) and -0.61 (±0.54) mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87) mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77) mm. All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.
Lopez, Mandi J; Davis, Kechia M; Jeffrey-Borger, Susan L; Markel, Mark D; Rettenmund, Christy
2009-12-01
To determine interobserver repeatability of measurements on computed tomography (CT) images of lax canine hip joints at different ages and in the presence of degenerative joint disease at maturity. Longitudinal observational investigation. Sibling crossbreed hounds. Pelvic CT was performed at 20, 24, 32, 48, 68, and 104 weeks of age. Measures were performed on 3 contiguous two-dimensional (2D) transverse CT images of both hips at each time point by 3 investigators. Center-edge angle (CEA), horizontal toit externe angle (HTEA), ventral (VASA), dorsal (DASA), and horizontal (HASA) acetabular sector angles, acetabular index (AI), and percent femoral head coverage (CPC) were measured. Interobserver repeatability was quantified with the intraclass correlation coefficient (ICC). Satisfactory repeatability was considered when ICC >or=0.75. DASA, CEA, and CPC were repeatable in all age groups. HASA and HTEA were repeatable for all but 1 time point. At 20 weeks of age, all measures but AI were repeatable, and at 104 weeks of age, DASA, CEA, CPC, and HASA were repeatable. Measures were repeatable in hips with and without degenerative changes with the exceptions of AI and HASA in normal hips and VASA and HTEA in osteoarthritic hips. Most 2D CT measurements examined were repeatable regardless of age or joint disease. Two-dimensional CT measures may augment current techniques for assessing joint changes in lax canine hips.
Repeated-sprint ability and team selection in Australian football league players.
Le Rossignol, Peter; Gabbett, Tim J; Comerford, Dan; Stanton, Warren R
2014-01-01
To investigate the relationship between selected physical capacities and repeated-sprint performance of Australian Football League (AFL) players and to determine which physical capacities contributed to being selected for the first competition game. Sum of skinfolds, 40-m sprint (with 10-, 20-, 30-, and 40-m splits), repeated-sprint ability (6 × 30-m sprints), and 3-km-run time were measured during the preseason in 20 AFL players. The physical qualities of players selected to play the first match of the season and those not selected were compared. Pearson correlation coefficients were used to determine the relationship among variables, and a regression analysis identified variables significantly related to repeated-sprint performance. In the regression analysis, maximum velocity was the best predictor of repeated-sprint time, with 3-km-run time also contributing significantly to the predictive model. Sum of skinfolds was significantly correlated with 10-m (r = .61, P < .01) and 30-m (r = .53, P < .05) sprint times. A 2.6% ± 2.1% difference in repeated-sprint time (P < .05, ES = 0.88 ± 0.72) was observed between those selected (25.26 ± 0.55 s) and not selected (25.82 ± 0.80 s) for the first game of the season. The findings indicate that maximum-velocity training using intervals of 30-40 m may contribute more to improving repeated-sprint performance in AFL players than short 10- to 20-m intervals from standing starts. Further research is warranted to establish the relative importance of endurance training for improving repeated-sprint performance in AFL football.
Reliability and criterion-related validity of a new repeated agility test
Makni, E; Jemni, M; Elloumi, M; Chamari, K; Nabli, MA; Padulo, J; Moalla, W
2016-01-01
The study aimed to assess the reliability and the criterion-related validity of a new repeated sprint T-test (RSTT) that includes intense multidirectional intermittent efforts. The RSTT consisted of 7 maximal repeated executions of the agility T-test with 25 s of passive recovery rest in between. Forty-five team sports players performed two RSTTs separated by 3 days to assess the reliability of best time (BT) and total time (TT) of the RSTT. The intra-class correlation coefficient analysis revealed a high relative reliability between test and retest for BT and TT (>0.90). The standard error of measurement (<0.50) showed that the RSTT has a good absolute reliability. The minimal detectable change values for BT and TT related to the RSTT were 0.09 s and 0.58 s, respectively. To check the criterion-related validity of the RSTT, players performed a repeated linear sprint (RLS) and a repeated sprint with changes of direction (RSCD). Significant correlations between the BT and TT of the RLS, RSCD and RSTT were observed (p<0.001). The RSTT is, therefore, a reliable and valid measure of the intermittent repeated sprint agility performance. As this ability is required in all team sports, it is suggested that team sports coaches, fitness coaches and sports scientists consider this test in their training follow-up. PMID:27274109
Accuracy of force and center of pressure measures of the Wii Balance Board.
Bartlett, Harrison L; Ting, Lena H; Bingham, Jeffrey T
2014-01-01
The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within ± 9.1N, and of COP location within ± 4.1mm. However, repeatability of a single measurement within a board was better (4.5 N, 1.5mm), suggesting that the WBB is best used for relative measures using the same device, rather than absolute measurement across devices. Internally stored calibration values were comparable to those determined experimentally. Further, heavy wear did not significantly degrade performance. In combination with prior evaluation of WBB performance and published standards for measuring human balance, our study provides necessary information to evaluate the use of the WBB for analysis of human balance control. We suggest the WBB may be useful for low-resolution measurements, but should not be considered as a replacement for laboratory-grade force plates. Published by Elsevier B.V.
Accuracy of force and center of pressure measures of the Wii Balance Board
Bartlett, Harrison L.; Ting, Lena H.; Bingham, Jeffrey T.
2013-01-01
The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within ±9.1 N, and of COP location within ±4.1 mm. However, repeatability of a single measurement within a board was better (4.5 N, 1.5 mm), suggesting that the WBB is best used for relative measures using the same device, rather than absolute measurement across devices. Internally stored calibration values were comparable to those determined experimentally. Further, heavy wear did not significantly degrade performance. In combination with prior evaluation of WBB performance and published standards for measuring human balance, our study provides necessary information to evaluate the use of the WBB for analysis of human balance control. We suggest the WBB may be useful for low-resolution measurements, but should not be considered as a replacement for laboratory-grade force plates. PMID:23910725
McFarquhar, Martyn; McKie, Shane; Emsley, Richard; Suckling, John; Elliott, Rebecca; Williams, Stephen
2016-05-15
Repeated measurements and multimodal data are common in neuroimaging research. Despite this, conventional approaches to group level analysis ignore these repeated measurements in favour of multiple between-subject models using contrasts of interest. This approach has a number of drawbacks as certain designs and comparisons of interest are either not possible or complex to implement. Unfortunately, even when attempting to analyse group level data within a repeated-measures framework, the methods implemented in popular software packages make potentially unrealistic assumptions about the covariance structure across the brain. In this paper, we describe how this issue can be addressed in a simple and efficient manner using the multivariate form of the familiar general linear model (GLM), as implemented in a new MATLAB toolbox. This multivariate framework is discussed, paying particular attention to methods of inference by permutation. Comparisons with existing approaches and software packages for dependent group-level neuroimaging data are made. We also demonstrate how this method is easily adapted for dependency at the group level when multiple modalities of imaging are collected from the same individuals. Follow-up of these multimodal models using linear discriminant functions (LDA) is also discussed, with applications to future studies wishing to integrate multiple scanning techniques into investigating populations of interest. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
2018-01-01
This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with different known Young’s modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981–1.000 and intraclass correlation 0.987–1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young’s modulus. All platforms had a coefficient of variation in the range 0.00–0.21 for all four phantoms, equivalent to low variance and high repeatability. PMID:29293527
Hall, L Malcolm; Collins, Catherine; Collet, Bertrand
2018-02-02
The utility of molecular response data arising from in-vivo single and repeated measure fish disease-challenge experiments is compared. An in-silico 'experiment' involving the generation of two imaginary immune-molecule quantity response profiles over time for individual animals was carried out. Daily 'observed' molecule quantities were drawn from the 'known' individual response profiles to mimic the results of single and repeated measurement. The results indicate that repeated measure experiments are required to infer individual level response profiles, and that these experiments also provide more accurate summary statistics and data more suited to inferring the dependent ordering of the molecular response. Additionally repeated measure experiments utilise fewer animals than single measure experiments. These results are described alongside a discussion of experimental methodological issues pertinent to the adoption of aquatic animal repeated measure experimental designs. We conclude that investigators need to take particular care when making inferences from single measure experiments and that serious consideration should be given to using repeated measure experiments for in-vivo fish disease-challenge investigations. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
The Effects of Oral and Silent Reading on Reading Comprehension
ERIC Educational Resources Information Center
Schimmel, Naomi; Ness, Molly
2017-01-01
This study examined the effects of reading mode (oral and silent) and text genre (narrative and expository) on fourth graders' reading comprehension. While controlling for prior reading ability of 48 participants, we measured comprehension. Using a repeated measured design, data were analyzed using analysis of covariance, paired t-tests, and…
ERIC Educational Resources Information Center
Marston, Doug; And Others
Two studies were conducted to examine the efficacy of direct measurement, standardized achievement tests, and aptitude-achievement discrepancy scores in distinguishing learning disabled (LD) and nonlearning disabled (NLD) students in grades 3 to 6. For both reading (Study I) and written expression (Study II), students' scores on direct and…
A Comparison of Four Approaches to Account for Method Effects in Latent State-Trait Analyses
ERIC Educational Resources Information Center
Geiser, Christian; Lockhart, Ginger
2012-01-01
Latent state-trait (LST) analysis is frequently applied in psychological research to determine the degree to which observed scores reflect stable person-specific effects, effects of situations and/or person-situation interactions, and random measurement error. Most LST applications use multiple repeatedly measured observed variables as indicators…
ERIC Educational Resources Information Center
Setzer, J. Carl; He, Yi
2009-01-01
Reliability Analysis for the Internationally Administered 2002 Series GED (General Educational Development) Tests Reliability refers to the consistency, or stability, of test scores when the authors administer the measurement procedure repeatedly to groups of examinees (American Educational Research Association [AERA], American Psychological…
Repeat surfactant therapy for postsurfactant slump.
Katz, L A; Klein, J M
2006-07-01
To evaluate repeat surfactant therapy for the treatment of respiratory failure associated with postsurfactant slump in extremely low birth weight infants (ELBW) by characterizing the population of premature infants who develop postsurfactant slump and measuring their response to a secondary course of surfactant therapy. A retrospective analysis of a cohort of all patients admitted over a 3-year period with birth weights <1000 g (ELBW infants). Information was collected by chart review and the patients were categorized into three distinct groups for analysis. Initial surfactant only, patients who received surfactant replacement therapy only for respiratory distress syndrome (RDS); repeat surfactant, patients who received both initial surfactant replacement for RDS and repeat surfactant therapy for postsurfactant slump (defined as respiratory failure after 6 days of age), and no surfactant, patients in whom no surfactant was ever administered. A respiratory severity score (RSS) was used to measure the severity of lung disease and response to surfactant therapy. Over 3 years, there were 165 ELBW infants who could develop postsurfactant slump and be eligible for repeat surfactant therapy. There were 39 infants who never received any surfactant therapy estimated gestational age (EGA) 27.7 +/- 1.7, birth weight 856 +/- 109 g) either at birth or after 6 days of life. There were 126 patients treated for RDS with initial surfactant replacement therapy (EGA 25.6 +/- 1.9 weeks, birth weight 713 +/- 179 g). Out of these RDS patients, 101 improved with an initial course of surfactant therapy (EGA 26 +/- 1.8, birth weight 751 +/- 143 g), but 25 (20% of the patients with RDS) developed postsurfactant slump and received a repeat course of surfactant therapy (EGA 24.7 +/- 1.2, birth weight 647 +/- 120 g). The repeat surfactant group (postsurfactant slump) was significantly more premature and had significantly lower birth weights compared to both the initial surfactant only group and the no surfactant ever group. Logistic regression analysis revealed that lack of antenatal steroids, earlier gestational age, and the receiving of 2 or more doses of surfactant to treat the initial RDS were significantly associated with receiving repeat surfactant therapy for postsurfactant slump. Of the 25 patients treated with a repeat course of surfactant therapy more than 70% of patients (n = 18) had an improvement in their lung disease with a 15% reduction in their RSS. This improvement was significant at all time points evaluated (12, 24, and 48 h). We found that a repeat course of surfactant therapy, after day of life 6, led to a significant improvement in hypoxemic respiratory failure in premature infants with postsurfactant slump. Infants who received repeat surfactant therapy were born at a significantly earlier gestational age, had significantly smaller birth weight and had significantly worse lung disease. They were significantly less likely to have received antenatal steroids and were significantly more likely to have received multiple doses of surfactant to treat their initial RDS. A repeat course of surfactant therapy for patients with postsurfactant slump appeared beneficial in the short-term. These initial findings would support performing randomized control trials of repeat surfactant therapy for postsurfactant slump.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendes, Milrian S.; Felinto, Daniel
2011-12-15
We analyze the efficiency and scalability of the Duan-Lukin-Cirac-Zoller (DLCZ) protocol for quantum repeaters focusing on the behavior of the experimentally accessible measures of entanglement for the system, taking into account crucial imperfections of the stored entangled states. We calculate then the degradation of the final state of the quantum-repeater linear chain for increasing sizes of the chain, and characterize it by a lower bound on its concurrence and the ability to violate the Clausner-Horne-Shimony-Holt inequality. The states are calculated up to an arbitrary number of stored excitations, as this number is not fundamentally bound for experiments involving large atomicmore » ensembles. The measurement by avalanche photodetectors is modeled by ''ON/OFF'' positive operator-valued measure operators. As a result, we are able to consistently test the approximation of the real fields by fields with a finite number of excitations, determining the minimum number of excitations required to achieve a desired precision in the prediction of the various measured quantities. This analysis finally determines the minimum purity of the initial state that is required to succeed in the protocol as the size of the chain increases. We also provide a more accurate estimate for the average time required to succeed in each step of the protocol. The minimum purity analysis and the new time estimates are then combined to trace the perspectives for implementation of the DLCZ protocol in present-day laboratory setups.« less
NASA Astrophysics Data System (ADS)
Mendes, Milrian S.; Felinto, Daniel
2011-12-01
We analyze the efficiency and scalability of the Duan-Lukin-Cirac-Zoller (DLCZ) protocol for quantum repeaters focusing on the behavior of the experimentally accessible measures of entanglement for the system, taking into account crucial imperfections of the stored entangled states. We calculate then the degradation of the final state of the quantum-repeater linear chain for increasing sizes of the chain, and characterize it by a lower bound on its concurrence and the ability to violate the Clausner-Horne-Shimony-Holt inequality. The states are calculated up to an arbitrary number of stored excitations, as this number is not fundamentally bound for experiments involving large atomic ensembles. The measurement by avalanche photodetectors is modeled by “ON/OFF” positive operator-valued measure operators. As a result, we are able to consistently test the approximation of the real fields by fields with a finite number of excitations, determining the minimum number of excitations required to achieve a desired precision in the prediction of the various measured quantities. This analysis finally determines the minimum purity of the initial state that is required to succeed in the protocol as the size of the chain increases. We also provide a more accurate estimate for the average time required to succeed in each step of the protocol. The minimum purity analysis and the new time estimates are then combined to trace the perspectives for implementation of the DLCZ protocol in present-day laboratory setups.
2013-01-01
Background The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. Methods In this prospective study, one eye was selected from each of 30 subjects for the measurements of ECD, CV and CCT, which were taken by two observers. Results were analyzed statistically by repeated-measures analysis of variance (ANOVA) for intra-observer repeatability, inter-observer reproducibility, unpaired t-test, paired t-test, and Bland–Altman analyses to determine limits of agreement (LOA) between the three instruments. Results Mean ECD, measured by SP-2000P and z-ring CS4, were 3115.50 ± 279.70 cells/mm2 and 3167.50 ± 264.75 cells/mm2, respectively (observer 1), and 3192.63 ± 249.42 cells/mm2 (z-ring, observer 2). Mean CV measurements were 27.12 ± 2.51 and 27.10 ± 2.41 (SP-2000P and z-ring CS4, respectively; observer 1), and 27.17 ± 2.25 (z-ring, observer 2). Mean CCT values were 555.11 ± 35.83 μm (USP), 535.82 ± 41.10 μm (SP-2000P) and 552.57 ± 36.83 μm (z-ring CS4), and 554.97 ± 36.34 μm (z-ring CS4, observer 2). However, pairwise tests in all cases there was good repeatability and reproducibility as shown by inter-observer and intra-observer analysis of variance for each of the instruments. Conclusions The SP-2000P and the z-ring CS4 can be used interchangeably to measure ECD and CV. For CCT, the sample size was too small to test for differences of the CCT measurements between the three instruments. PMID:24274022
Arnold, Patricia A; Ellerbrock, Emily R; Bowman, Lyn; Loucks, Anne B
2014-11-07
Osteoporosis is characterized by reduced bone strength, but no FDA-approved medical device measures bone strength. Bone strength is strongly associated with bone stiffness, but no FDA-approved medical device measures bone stiffness either. Mechanical Response Tissue Analysis (MRTA) is a non-significant risk, non-invasive, radiation-free, vibration analysis technique for making immediate, direct functional measurements of the bending stiffness of long bones in humans in vivo. MRTA has been used for research purposes for more than 20 years, but little has been published about its accuracy. To begin to investigate its accuracy, we compared MRTA measurements of bending stiffness in 39 artificial human ulna bones to measurements made by Quasistatic Mechanical Testing (QMT). In the process, we also quantified the reproducibility (i.e., precision and repeatability) of both methods. MRTA precision (1.0±1.0%) and repeatability (3.1 ± 3.1%) were not as high as those of QMT (0.2 ± 0.2% and 1.3+1.7%, respectively; both p<10(-4)). The relationship between MRTA and QMT measurements of ulna bending stiffness was indistinguishable from the identity line (p=0.44) and paired measurements by the two methods agreed within a 95% confidence interval of ± 5%. If such accuracy can be achieved on real human ulnas in situ, and if the ulna is representative of the appendicular skeleton, MRTA may prove clinically useful. Copyright © 2014 Elsevier Ltd. All rights reserved.
Jambor, Ivan; Merisaari, Harri; Aronen, Hannu J; Järvinen, Jukka; Saunavaara, Jani; Kauko, Tommi; Borra, Ronald; Pesola, Marko
2014-05-01
To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. Optimal b-value distributions for the fit of three parameters (fast diffusion Df, slow diffusion Ds, and fraction of fast diffusion f) were determined using Monte-Carlo simulations. The optimal b-value distribution was calculated using four individual optimization methods. Eight healthy volunteers underwent four repeated 3 Tesla prostate DWI scans using both 16 equally distributed b-values and an optimized b-value distribution obtained from the simulations. The b-value distributions were compared in terms of measurement reliability and repeatability using Shrout-Fleiss analysis. Using low noise levels, the optimal b-value distribution formed three separate clusters at low (0-400 s/mm2), mid-range (650-1200 s/mm2), and high b-values (1700-2000 s/mm2). Higher noise levels resulted into less pronounced clustering of b-values. The clustered optimized b-value distribution demonstrated better measurement reliability and repeatability in Shrout-Fleiss analysis compared with 16 equally distributed b-values. The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments. Copyright © 2013 Wiley Periodicals, Inc.
Overall, John E; Tonidandel, Scott; Starbuck, Robert R
2006-01-01
Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.
Measurement of cardiac output using improved chromatographic analysis of sulfur hexafluoride (SF6).
Klocke, F J; Roberts, D L; Farhi, E R; Naughton, B J; Sekovski, B; Klocke, R A
1977-06-01
A constant current variable frequency pulsed electron capture detector has been incorporated into the gas chromatographic analysis of trace amounts of sulfur hexafluoride (SF6) in water and blood. The resulting system offers a broader effective operating range than more conventional electron capture units and has been utilized for measurements of cardiac output employing constant-rate infusion of dissolved SF6. The SF6 technique has been validated against direct volumetric measurements of cardiac output in a canine right-heart bypass preparation and used subsequently for rapidly repeated measurements in conscious animals and man.
Repeatability of Spectral Domain Optical Coherence Tomography Measurements in High Myopia.
Rao, Harsha L; Kumar, Addepalli U; Bonala, Sampath R; Yogesh, Kadam; Lakshmi, Bodduluri
2016-05-01
The purpose of this study was to compare the repeatability of spectral domain optical coherence tomography (SDOCT) parameters in high-myopic and emmetropic healthy subjects, and to evaluate the influence of axial length on the repeatability of SDOCT parameters in high myopia. In a prospective study, 93 eyes of 63 high-myopic subjects (spherical refractive error, -6 to -12 D; median age, 25 y) and 28 eyes of 14 emmetropic (spherical refractive error, 0 D; median age, 30 y) subjects underwent optic nerve head, retinal nerve fiber layer (RNFL), and ganglion cell complex imaging with SDOCT. For the repeatability analysis, 31 eyes of 31 high-myopic subjects and 14 eyes of 14 emmetropic subjects underwent 3 repeated scans in the same session. Among the optic nerve head parameters, within-subject coefficient of variation (CVw) measurements of the disc area (0.6% vs. 0.2%), rim area (8.7 vs. 2.8), and rim volume (16.7 vs. 8.9) were significantly larger (worse) in high-myopic compared with the emmetropic subjects. CVw measurements of all RNFL (range, 1.7 to 22.4) and ganglion cell complex (range, 1.8 to 2.5) parameters in high-myopic subjects were comparable to that in emmetropic subjects (2.4 to 24.0 and 1.7 to 2.0, respectively). Axial length significantly affected the CVw of nasal (coefficient, 0.01; P=0.04) and average RNFL (coefficient, 0.004; P=0.001) parameters but not that of the other SDOCT parameters. Repeatabilities of most of the SDOCT parameters in high-myopic subjects were good and comparable to that of emmetropic subjects. This suggests that SDOCT can be useful for following up high-myopic glaucoma patients to detect progression.
A model for incomplete longitudinal multivariate ordinal data.
Liu, Li C
2008-12-30
In studies where multiple outcome items are repeatedly measured over time, missing data often occur. A longitudinal item response theory model is proposed for analysis of multivariate ordinal outcomes that are repeatedly measured. Under the MAR assumption, this model accommodates missing data at any level (missing item at any time point and/or missing time point). It allows for multiple random subject effects and the estimation of item discrimination parameters for the multiple outcome items. The covariates in the model can be at any level. Assuming either a probit or logistic response function, maximum marginal likelihood estimation is described utilizing multidimensional Gauss-Hermite quadrature for integration of the random effects. An iterative Fisher-scoring solution, which provides standard errors for all model parameters, is used. A data set from a longitudinal prevention study is used to motivate the application of the proposed model. In this study, multiple ordinal items of health behavior are repeatedly measured over time. Because of a planned missing design, subjects answered only two-third of all items at a given point. Copyright 2008 John Wiley & Sons, Ltd.
Nkenke, Emeka; Lehner, Bernhard; Kramer, Manuel; Haeusler, Gerd; Benz, Stefanie; Schuster, Maria; Neukam, Friedrich W; Vairaktaris, Eleftherios G; Wurm, Jochen
2006-03-01
To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Technical report, reliability study. Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. The method errors were less than 1 mm for distances and less than 1.5 degrees for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.
Sehi, M; Flanagan, J G
2004-01-01
Aim: To examine the influence of image alignment on the repeatability of blood flow measurements of the optic nerve. Methods: 10 normal subjects were examined. Heidelberg retina tomograph imaging was performed to establish best location and focus for the temporal neuroretinal rim. Two high quality Heidelberg retina flowmeter (HRF) images were acquired for three methods of alignment: central, nasal, and temporal. A 10×10 pixel measurement window was selected and exactly reproduced on all images. The interquartile pixel values were used to calculate capillary flow. ANOVA, intraclass correlation coefficients (ICC) and the coefficient of repeatability (CoR) were used for analysis. Results: There was no difference between methods (p = 0.47) or between visits (p = 0.51). The ICCs were 0.83 for the central, 0.34 for the nasal, and 0.42 for the temporal alignment. The CoR was 31.5 for central (mean effect 235.1), 234.6 for nasal, and 256.7 for temporal alignment. Conclusion: Central alignment was the most repeatable method for the measurement of neuroretinal rim capillary blood flow using the HRF. PMID:14736775
Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET.
Ocneanu, Adrian F; deKemp, Robert A; Renaud, Jennifer M; Adler, Andy; Beanlands, Rob S B; Klein, Ran
2017-01-01
Purpose. Myocardial blood flow (MBF) quantification with 82 Rb positron emission tomography (PET) is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic 82 Rb PET, from which MBF was quantified using 1-tissue-compartment kinetic model variants: (1) blood-pool versus uptake region sampled input function (Blood/Uptake-ROI), (2) dual spillover correction (SOC-On/Off), (3) right blood correction (RBC-On/Off), (4) arterial blood transit delay (Delay-On/Off), and (5) distribution volume (DV) constraint (Global/Regional-DV). Repeatability of MBF, stress/rest myocardial flow reserve (MFR), and stress/rest MBF difference (ΔMBF) was assessed using nonparametric reproducibility coefficients (RPC np = 1.45 × interquartile range). Results. MBF using SOC-On, RVBC-Off, Blood-ROI, Global-DV, and Delay-Off was most repeatable for combined rest and stress: RPC np = 0.21 mL/min/g (15.8%). Corresponding MFR and ΔMBF RPC np were 0.42 (20.2%) and 0.24 mL/min/g (23.5%). MBF repeatability improved with SOC-On at stress ( p < 0.001) and tended to improve with RBC-Off at both rest and stress ( p < 0.08). DV and ROI did not significantly influence repeatability. The Delay-On model was overdetermined and did not reliably converge. Conclusion. MBF and MFR test-retest repeatability were the best with dual spillover correction, left atrium blood input function, and global DV.
Prakash, Gaurav; Srivastava, Dhruv; Choudhuri, Sounak
2015-12-01
The purpose of this study is to analyze the repeatability and agreement of corneal power using a new Hartman type topographer in comparison to Scheimpflug+Placido and autorefractor devices. In this cross sectional, observational study performed at the cornea services of a specialty hospital, 100 normal eyes (100 consecutive candidates) without any previous ocular surgery or morbidity except refractive error were evaluated. All candidates underwent three measurements each on a Full gradient, Hartman type topographer (FG) (iDesign, AMO), Scheimpflug+Placido topographer (SP) (Sirius, CSO) and rotating prism auto-keratorefractor (AR) (KR1, Nidek). The parameters assessed were flat keratometry (K1), steep keratometry (K2), steep axis (K2 axis), mean K, J 0 and J 45. Intra-device repeatability and inter-device agreement were evaluated. On repeatability analysis, the intra-device means were not significantly different (ANOVA, p > 0.05). Intraclass correlations (ICC) were >0.98 except for J 0 and J 45. In terms of intra-measurement standard deviation (Sw), the SP and FG groups fared better than AR group (p < 0.001, ANOVA). On Sw versus Average plots, no significantly predictive fit was seen (p > 0.05, R (2) < 0.1 for all the values). On inter-device agreement analysis, there was no difference in means (ANOVA, p > 0.05). ICC ranged from 0.92 to 0.99 (p < 0.001). Regression fits on Bland-Altman plots suggested no clinically significant effect of average values over difference in means. The repeatability of Hartman type topographer in normal eyes is comparable to SP combination device and better than AR. The agreement between the three devices is good. However, we recommend against interchanging these devices between follow-ups or pooling their data.
Dong, Yuanjun; Zhang, Guiqing; Yuan, Xiuyu; Zhang, Yueqi; Hu, Min
2016-05-01
The aim of the present study was to explore the telomere length of peripheral blood leukocytes from a rat model of post-traumatic stress disorder (PTSD), as well as the expression level of telomere-binding protein in the hippocampal CA1 region. The PTSD model was established with 42 adult male Wistar rats. The relative telomere length of the leukocytes was measured by real-time fluorescence quantitative polymerase chain reaction, and the expression levels of telomere repeating factor 1 (TRF1) and telomere repeating factor 2 (TRF2) in the hippocampal CA1 region of the PTSD rat model were determined by immunofluorescence technology. The covariance analysis of repeated measurements by the mixed model approach was used for the telomere length analysis. The comparison of averaged data among groups was performed using least significant difference and analysis of variance. The Student's t test or the Mann-Whitney U test was used for intragroup comparison. The association study among groups was conducted using the Spearman test. The shortening speed of telomere length significantly accelerated in rats after Single Prolonged Stress (SPS) stimulation (P<0.05). The expression levels of TRF1 and TRF2 increased with the progress of PTSD, and the expression peak was shown in day 14, which was significantly different from the control group (P<0.05). The shortening speed of the telomere length of peripheral blood leukocytes accelerated in PTSD rats, and the expression levels of TRF1 and TRF2 increased in hippocampus, both of which were closely associated with the pathological progress of the PTSD-like model and unfavorable prognosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Farokhmanesh, Khatere; Shirzadian, Toraj; Mahboubi, Mohammad; Shahri, Mina Neyakan
2014-01-01
Based on clinical observations, foot hyperpronation is very common. Excessive pronation (hyperpronation) can cause malalignment of the lower extremities. This most often leads to functional and structural deficits. The aim of this study was to assess the effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis. Thirty five healthy subjects (age range, 18030 years) were asked to stand on 4 positions including a flat surface (normal position) and on wedges angled at 10, 15, and 20 degrees. Sampling was done using simple random sampling. Measurements were made by a motion analysis system. For data analysis, the SPSS software (ver. 18) using paired t-test and repeated measures analysis of variance (ANOVA) was applied. The eversion created by the wedges caused a significant increase in lumbar lordosis and thoracic kyphosis. The most significant change occurred between two consecutive positions of flat surface and the first wedge. The t-test for repeated measures showed a high correlation between each two consecutive positions. The results showed that with increased bilateral foot pronation, lumbar lordosis and thoracic kyphosis increased as well. In fact, each of these results is a compensation phenomenon. Further studies are required to determine long-term results of excessive foot pronation and its probable effect on damage progression. PMID:25169004
Farokhmanesh, Khatere; Shirzadian, Toraj; Mahboubi, Mohammad; Shahri, Mina Neyakan
2014-06-17
Based on clinical observations, foot hyperpronation is very common. Excessive pronation (hyperpronation) can cause malalignment of the lower extremities. This most often leads to functional and structural deficits. The aim of this study was to assess the effect of foot hyperpronation on lumbar lordosis and thoracic kyphosis. Thirty five healthy subjects (age range, 18030 years) were asked to stand on 4 positions including a flat surface (normal position) and on wedges angled at 10, 15, and 20 degrees. Sampling was done using simple random sampling. Measurements were made by a motion analysis system. For data analysis, the SPSS software (ver. 18) using paired t-test and repeated measures analysis of variance (ANOVA) was applied. The eversion created by the wedges caused a significant increase in lumbar lordosis and thoracic kyphosis. The most significant change occurred between two consecutive positions of flat surface and the first wedge. The t-test for repeated measures showed a high correlation between each two consecutive positions. The results showed that with increased bilateral foot pronation, lumbar lordosis and thoracic kyphosis increased as well. In fact, each of these results is a compensation phenomenon. Further studies are required to determine long-term results of excessive foot pronation and its probable effect on damage progression.
Charles H. (Hobie) Perry; Kevin J. Horn; R. Quinn Thomas; Linda H. Pardo; Erica A.H. Smithwick; Doug Baldwin; Gregory B. Lawrence; Scott W. Bailey; Sabine Braun; Christopher M. Clark; Mark Fenn; Annika Nordin; Jennifer N. Phelan; Paul G. Schaberg; Sam St. Clair; Richard Warby; Shaun Watmough; Steven S. Perakis
2015-01-01
The abundance of temporally and spatially consistent Forest Inventory and Analysis data facilitates hierarchical/multilevel analysis to investigate factors affecting tree growth, scaling from plot-level to continental scales. Herein we use FIA tree and soil inventories in conjunction with various spatial climate and soils data to estimate species-specific responses of...
Within-Subject Comparison of Changes in a Pretest-Posttest Design
ERIC Educational Resources Information Center
Hennig, Christian; Mullensiefen, Daniel; Bargmann, Jens
2010-01-01
The authors propose a method to compare the influence of a treatment on different properties within subjects. The properties are measured by several Likert-type-scaled items. The results show that many existing approaches, such as repeated measurement analysis of variance on sum and mean scores, a linear partial credit model, and a graded response…
ERIC Educational Resources Information Center
Dundas, Ingrid; Thorsheim, Torbjørn; Hjeltnes, Aslak; Binder, Per Einar
2016-01-01
Mindfulness based stress reduction (MBSR) for academic evaluation anxiety and self-confidence in 70 help-seeking bachelor's and master's students was examined. A repeated measures analysis of covariance on the 46 students who completed pretreatment and posttreatment measures (median age = 24 years, 83% women) showed that evaluation anxiety and…
Bright, Molly G; Murphy, Kevin
2013-12-01
Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC<0.4) in several regions analysed. In contrast, the end-tidal CO2 regressors resulted in "excellent" repeatability (ICC=0.82) in the average grey matter data, and resulted in acceptable repeatability in all smaller regions tested (ICC>0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable measurement of CVR that makes breath-hold challenges suitable for routine clinical practice. © 2013.
Repeatability of Monocular Acuity Testing in Adults with and without Down Syndrome.
Ravikumar, Ayeswarya; Benoit, Julia S; Morrison, Kelsie B; Marsack, Jason D; Anderson, Heather A
2018-03-01
Individuals with Down syndrome may experience greater difficulty reliably performing visual acuity (VA) tests because of intellectual disability and limitations in visual quality. This study evaluated the repeatability of acuity (Bailey-Lovie [BL] and HOTV) in subjects with and without Down syndrome. High-contrast VA was measured in both eyes of 30 subjects with Down syndrome (mean, 30 years; range, 18 to 50 years) and 24 control subjects without Down syndrome (mean, 29 years; range, 18 to 50 years). In the Down syndrome group, 23 subjects performed BL, and 7 subjects performed HOTV. All control subjects performed both BL and HOTV, but for HOTV analysis, only seven age-matched control subjects were included. For each eye, subjects performed VA three times on different charts (computer controlled, single-line display) until five total letters were missed on each chart. A repeated-measure ANOVA was used to compare the acuity measures between groups. The average logMAR VA for subjects with Down syndrome was approximately six lines worse than the control subjects (BL: Down syndrome = right eye: 0.51 ± 0.16, left eye: 0.53 ± 0.18; control = right eye: -0.06 ± 0.06, left eye: -0.06 ± 0.08, P < .0001; HOTV: Down syndrome = right eye: 0.47 ± 0.19, left eye: 0.46 ± 0.16; control: right eye = -0.11 ± 0.09, left eye: -0.07 ± 0.07, P < .001). Bailey-Lovie VA repeatability (1.96 * Sw * √2) was 0.13 logMAR (6.5 letters) for Down syndrome and 0.09 logMAR (4.5 letters) for control subjects. HOTV VA repeatability was 0.16 logMAR (eight letters) for both Down syndrome and control subjects. Despite poorer acuity in individuals with Down syndrome, repeatability of VA measurements was comparable to control subjects for both BL and HOTV techniques.
Design and analysis of an automatic method of measuring silicon-controlled-rectifier holding current
NASA Technical Reports Server (NTRS)
Maslowski, E. A.
1971-01-01
The design of an automated SCR holding-current measurement system is described. The circuits used in the measurement system were designed to meet the major requirements of automatic data acquisition, reliability, and repeatability. Performance data are presented and compared with calibration data. The data verified the accuracy of the measurement system. Data taken over a 48-hr period showed that the measurement system operated satisfactorily and met all the design requirements.
NASA Technical Reports Server (NTRS)
Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.
2010-01-01
Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.
From Gain Score t to ANCOVA F (and Vice Versa)
ERIC Educational Resources Information Center
Knapp, Thomas R.; Schafer, William D.
2009-01-01
Although they test somewhat different hypotheses, analysis of gain scores (or its repeated-measures analog) and analysis of covariance are both common methods that researchers use for pre-post data. The results of the two approaches yield non-comparable outcomes, but since the same generic data are used, it is possible to transform the test…
Effective Use of Multimedia Presentations to Maximize Learning within High School Science Classrooms
ERIC Educational Resources Information Center
Rapp, Eric
2013-01-01
This research used an evidenced-based experimental 2 x 2 factorial design General Linear Model with Repeated Measures Analysis of Covariance (RMANCOVA). For this analysis, time served as the within-subjects factor while treatment group (i.e., static and signaling, dynamic and signaling, static without signaling, and dynamic without signaling)…
Modeling Longitudinal Data with Generalized Additive Models: Applications to Single-Case Designs
ERIC Educational Resources Information Center
Sullivan, Kristynn J.; Shadish, William R.
2013-01-01
Single case designs (SCDs) are short time series that assess intervention effects by measuring units repeatedly over time both in the presence and absence of treatment. For a variety of reasons, interest in the statistical analysis and meta-analysis of these designs has been growing in recent years. This paper proposes modeling SCD data with…
Repeatability and Accuracy of Exoplanet Eclipse Depths Measured with Post-cryogenic Spitzer
NASA Astrophysics Data System (ADS)
Ingalls, James G.; Krick, J. E.; Carey, S. J.; Stauffer, John R.; Lowrance, Patrick J.; Grillmair, Carl J.; Buzasi, Derek; Deming, Drake; Diamond-Lowe, Hannah; Evans, Thomas M.; Morello, G.; Stevenson, Kevin B.; Wong, Ian; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa
2016-08-01
We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μm data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble, 5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.
Intramyocellular lipid quantification: repeatability with 1H MR spectroscopy.
Torriani, Martin; Thomas, Bijoy J; Halpern, Elkan F; Jensen, Megan E; Rosenthal, Daniel I; Palmer, William E
2005-08-01
To prospectively determine the repeatability and variability of tibialis anterior intramyocellular lipid (IMCL) quantifications performed by using 1.5-T hydrogen 1 (1H) magnetic resonance (MR) spectroscopy in healthy subjects. Institutional review board approval and written informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. The authors examined the anterior tibial muscles of 27 healthy subjects aged 19-48 years (12 men, 15 women; mean age, 25 years) by using single-voxel short-echo-time point-resolved 1H MR spectroscopy. During a first visit, the subjects underwent 1H MR spectroscopy before and after being repositioned in the magnet bore, with voxels carefully placed on the basis of osseous landmarks. Measurements were repeated after a mean interval of 12 days. All spectra were fitted by using Java-based MR user interface (jMRUI) and LCModel software, and lipid peaks were scaled to the unsuppressed water peak (at 4.7 ppm) and the total creatine peak (at approximately 3.0 ppm). A one-way random-effects variance components model was used to determine intraday and intervisit coefficients of variation (CVs). A power analysis was performed to determine the detectable percentage change in lipid measurements for two subject sample sizes. Measurements of the IMCL methylene protons peak at a resonance of 1.3 ppm scaled to the unsuppressed water peak (IMCL(W)) that were obtained by using jMRUI software yielded the lowest CVs overall (intraday and intervisit CVs, 13.4% and 14.4%, respectively). The random-effects variance components model revealed that nonbiologic factors (equipment and repositioning) accounted for 50% of the total variability in IMCL quantifications. Power analysis for a sample size of 20 subjects revealed that changes in IMCL(W) of greater than 15% could be confidently detected between 1H MR spectroscopic measurements obtained on different days. 1H MR spectroscopy is feasible for repeatable quantification of IMCL concentrations in longitudinal studies of muscle metabolism.
Al-Farhan, Haya M; AlMutairi, Reem N
2013-01-01
Purpose To compare the precision of anterior chamber angle (ACA) and anterior chamber depth (ACD) measurements taken with ultrasound biomicroscopy (UBM) and the Artemis-2 Very High Frequency Ultrasound Scanner (VHFUS) in normal subjects. Design Prospective study. Methods We randomly selected one eye from each of 59 normal subjects in this study. Two subjects dropped out of the study; the associated data were excluded from analysis. ACA and ACD measurements were obtained using the VHFUS and the UBM. The results were compared statistically using repeated-measures analysis of variance for the intraobserver repeatability, unpaired t-test, and limits of agreement. Results The average ACA values for the UBM and the VHFUS (±standard deviation) were 41.83° ± 5.03° and 33.36° ± 6.03°, respectively. The average ACD values were 2.96 ± 0.34 mm and 2.87 ± 0.31 mm. The intraobserver repeatability analysis of variance P-values for ACA and ACD measurements using UBM were 0.10 and 0.68, respectively; for the Artemis-2 VHFUS, the respective values were 0.68 and 0.09. The difference in ACA measurements was statistically significant (t = 8.41; P < 0.0001), while the difference in ACD values was not (t = 1.51; P < 0.13). The mean ACA difference was 8.50° ± 2.50°, and the limits of agreement were +13.30° to −3.60°. The mean ACD difference was 0.09 ± 0.27 mm, and the limits of agreement ranged from 0.61 mm to −0.43 mm. The mean difference percentage of ACD was 3.1% for both instruments. Conclusion In case of the ACD, both instruments can be used interchangeably; however, with the ACA instruments, they cannot be used interchangeably. PMID:23345968
Investigation of relationships between AIMS shape properties and VST friction values.
DOT National Transportation Integrated Search
2015-02-01
A thorough analysis was conducted for AIMS shape properties measured for virgin aggregates, aggregates : polished in the Micro-Deval (MD) for 105 and 210 minutes, and VST friction samples. Excellent repeatability of : AIMS angularity and texture meas...
Demonstration of repeatability in a high-energy-density planar shear mixing layer experiment
Merritt, Elizabeth Catherine; Doss, Forrest William; Di Stefano, Carlos A.; ...
2017-03-11
On laser-driven platforms the assumption of experiment repeatability is particularly important due to a typically low data acquisition rate that doesn’t often allow for data redundancy. If the platform is repeatable, then measurements of the repeatable dynamics from multiple experiments can be treated as measurements of the same system. In high-energy-density hydrodynamic instability experiments the interface growth is assumed to be one of the repeatable aspects of the system. In this paper we demonstrate the repeatability of the instability growth in the counter-propagating shear experiment at the OMEGA laser facility, where the instability growth is characterized by the tracer layermore » thickness or mix-width evolution. Furthermore, in our previous experiment campaigns we have assumed the instability growth was repeatable enough to identify trends, but in this work we explicitly show that the mix-width measurements for nominally identical experiments are repeatable within the measurement error bars.« less
St. Pierre, Tim G.; House, Michael J.; Bangma, Sander J.; Pang, Wenjie; Bathgate, Andrew; Gan, Eng K.; Ayonrinde, Oyekoya T.; Bhathal, Prithi S.; Clouston, Andrew; Olynyk, John K.; Adams, Leon A.
2016-01-01
Background and Aims Validation of non-invasive methods of liver fat quantification requires a reference standard. However, using standard histopathology assessment of liver biopsies is problematical because of poor repeatability. We aimed to assess a stereological method of measuring volumetric liver fat fraction (VLFF) in liver biopsies and to use the method to validate a magnetic resonance imaging method for measurement of VLFF. Methods VLFFs were measured in 59 subjects (1) by three independent analysts using a stereological point counting technique combined with the Delesse principle on liver biopsy histological sections and (2) by three independent analysts using the HepaFat-Scan® technique on magnetic resonance images of the liver. Bland Altman statistics and intraclass correlation (IC) were used to assess the repeatability of each method and the bias between the methods of liver fat fraction measurement. Results Inter-analyst repeatability coefficients for the stereology and HepaFat-Scan® methods were 8.2 (95% CI 7.7–8.8)% and 2.4 (95% CI 2.2–2.5)% VLFF respectively. IC coefficients were 0.86 (95% CI 0.69–0.93) and 0.990 (95% CI 0.985–0.994) respectively. Small biases (≤3.4%) were observable between two pairs of analysts using stereology while no significant biases were observable between any of the three pairs of analysts using HepaFat-Scan®. A bias of 1.4±0.5% VLFF was observed between the HepaFat-Scan® method and the stereological method. Conclusions Repeatability of the stereological method is superior to the previously reported performance of assessment of hepatic steatosis by histopathologists and is a suitable reference standard for validating non-invasive methods of measurement of VLFF. PMID:27501242
Agius, P A; Aitken, C K; Breen, C; Dietze, P M
2018-06-04
We sought to establish the extent of repeat participation in a large annual cross-sectional survey of people who inject drugs and assess its implications for analysis. We used "porn star names" (the name of each participant's first pet followed by the name of the first street in which they lived) to identify repeat participation in three Australian Illicit Drug Reporting System surveys. Over 2013-2015, 2468 porn star names (96.2%) appeared only once, 88 (3.4%) twice, and nine (0.4%) in all 3 years. We measured design effects, based on the between-cluster variability for selected estimates, of 1.01-1.07 for seven key variables. These values indicate that the complex sample is (e.g.) 7% less efficient in estimating prevalence of heroin use (ever) than a simple random sample, and 1% less efficient in estimating number of heroin overdoses (ever). Porn star names are a useful means of tracking research participants longitudinally while maintaining their anonymity. Repeat participation in the Australian Illicit Drug Reporting System is low (less than 5% per annum), meaning point-prevalence and effect estimation without correction for the lack of independence in observations is unlikely to seriously affect population inference.
NASA Technical Reports Server (NTRS)
Kvetnansky, R.; Mitro, A.; Mikulaj, L.; Hocman, G.
1980-01-01
Changes of the adrenal medulla of rats were studied in the course of adaptation to repeated immobilization stress. An increase in the number of cells in the adrenal medulla was found in the adapted animals; this increase was confirmed by weight indices of the medulla and by cell counts per surface unit. Simultaneous karyometric measurements of the nuclei of adrenal medulla cells and an analysis of the catecholamine contents in the adrenals explain the increased activity of the adrenal medulla in the course of adaptation.
Weber, P.K.; Bacon, C.R.; Hutcheon, I.D.; Ingram, B.L.; Wooden, J.L.
2005-01-01
The ion microprobe has the capability to generate high resolution, high precision isotopic measurements, but analysis of the isotopic composition of strontium, as measured by the 87Sr/ 86Sr ratio, has been hindered by isobaric interferences. Here we report the first high precision measurements of 87Sr/ 86Sr by ion microprobe in calcium carbonate samples with moderate Sr concentrations. We use the high mass resolving power (7000 to 9000 M.R.P.) of the SHRIMP-RG ion microprobe in combination with its high transmission to reduce the number of interfering species while maintaining sufficiently high count rates for precise isotopic measurements. The isobaric interferences are characterized by peak modeling and repeated analyses of standards. We demonstrate that by sample-standard bracketing, 87Sr/86Sr ratios can be measured in inorganic and biogenic carbonates with Sr concentrations between 400 and 1500 ppm with ???2??? external precision (2??) for a single analysis, and subpermil external precision with repeated analyses. Explicit correction for isobaric interferences (peak-stripping) is found to be less accurate and precise than sample-standard bracketing. Spatial resolution is ???25 ??m laterally and 2 ??m deep for a single analysis, consuming on the order of 2 ng of material. The method is tested on otoliths from salmon to demonstrate its accuracy and utility. In these growth-banded aragonitic structures, one-week temporal resolution can be achieved. The analytical method should be applicable to other calcium carbonate samples with similar Sr concentrations. Copyright ?? 2005 Elsevier Ltd.
Applying Quantitative Genetic Methods to Primate Social Behavior
Brent, Lauren J. N.
2013-01-01
Increasingly, behavioral ecologists have applied quantitative genetic methods to investigate the evolution of behaviors in wild animal populations. The promise of quantitative genetics in unmanaged populations opens the door for simultaneous analysis of inheritance, phenotypic plasticity, and patterns of selection on behavioral phenotypes all within the same study. In this article, we describe how quantitative genetic techniques provide studies of the evolution of behavior with information that is unique and valuable. We outline technical obstacles for applying quantitative genetic techniques that are of particular relevance to studies of behavior in primates, especially those living in noncaptive populations, e.g., the need for pedigree information, non-Gaussian phenotypes, and demonstrate how many of these barriers are now surmountable. We illustrate this by applying recent quantitative genetic methods to spatial proximity data, a simple and widely collected primate social behavior, from adult rhesus macaques on Cayo Santiago. Our analysis shows that proximity measures are consistent across repeated measurements on individuals (repeatable) and that kin have similar mean measurements (heritable). Quantitative genetics may hold lessons of considerable importance for studies of primate behavior, even those without a specific genetic focus. PMID:24659839
Analysis of polyethylene wear in plain radiographs
2009-01-01
Background and purpose Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a different number of radiographs. Methods We used either 1, 2, or 6 anteroposterior (AP) hip radiographs of 11 patients from a clinical THA series with 12 years of follow-up, and measured the PE wear with the software PolyWare 3D Pro. Repeatability within and concurrent validity between the different numbers of radiograph strategies were assessed using limits of agreement (LOAs) and bias. Results Observed median wear (range) in mm was 3.4 (1.6–4.6), 2.3 (0.7–4.9), and 4.0 (2.6–6.2) for the 1-, 2-, and 6-radiograph strategies. For repeatability, no bias (p > 0.41) was observed. LOAs around the bias were ± 0.6, ± 0.4, and ± 1.2 mm for the 1-, 2-, and 6-radiograph strategies. For concurrent validity, a bias (± LOA) between all pairwise comparisons was observed (p < 0.02) with 0.8 mm (± 2.5) between the 1- and 2-radiograph strategies, 1.0 mm (± 2.2) between the 1- and 6-radiograph strategies, and 1.8 mm (± 1.2) between the 2- and 6-radiograph strategies. Interpretation The number of radiographs used for wear measurement with a shadow-casting analysis method on plain AP radiographs influences the amount of linear wear measured. Results of PE wear obtained with PolyWare in studies using a different number of radiographs are not comparable. PMID:19995318
Langarika-Rocafort, Argia; Emparanza, José Ignacio; Aramendi, José F; Castellano, Julen; Calleja-González, Julio
2017-01-01
To examine the intra-observer reliability and agreement between five methods of measurement for dorsiflexion during Weight Bearing Dorsiflexion Lunge Test and to assess the degree of agreement between three methods in female athletes. Repeated measurements study design. Volleyball club. Twenty-five volleyball players. Dorsiflexion was evaluated using five methods: heel-wall distance, first toe-wall distance, inclinometer at tibia, inclinometer at Achilles tendon and the dorsiflexion angle obtained by a simple trigonometric function. For the statistical analysis, agreement was studied using the Bland-Altman method, the Standard Error of Measurement and the Minimum Detectable Change. Reliability analysis was performed using the Intraclass Correlation Coefficient. Measurement methods using the inclinometer had more than 6° of measurement error. The angle calculated by trigonometric function had 3.28° error. The reliability of inclinometer based methods had ICC values < 0.90. Distance based methods and trigonometric angle measurement had an ICC values > 0.90. Concerning the agreement between methods, there was from 1.93° to 14.42° bias, and from 4.24° to 7.96° random error. To assess DF angle in WBLT, the angle calculated by a trigonometric function is the most repeatable method. The methods of measurement cannot be used interchangeably. Copyright © 2016 Elsevier Ltd. All rights reserved.
Analysis of sequence repeats of proteins in the PDB.
Mary Rajathei, David; Selvaraj, Samuel
2013-12-01
Internal repeats in protein sequences play a significant role in the evolution of protein structure and function. Applications of different bioinformatics tools help in the identification and characterization of these repeats. In the present study, we analyzed sequence repeats in a non-redundant set of proteins available in the Protein Data Bank (PDB). We used RADAR for detecting internal repeats in a protein, PDBeFOLD for assessing structural similarity, PDBsum for finding functional involvement and Pfam for domain assignment of the repeats in a protein. Through the analysis of sequence repeats, we found that identity of the sequence repeats falls in the range of 20-40% and, the superimposed structures of the most of the sequence repeats maintain similar overall folding. Analysis sequence repeats at the functional level reveals that most of the sequence repeats are involved in the function of the protein through functionally involved residues in the repeat regions. We also found that sequence repeats in single and two domain proteins often contained conserved sequence motifs for the function of the domain. Copyright © 2013 Elsevier Ltd. All rights reserved.
Regression analysis using dependent Polya trees.
Schörgendorfer, Angela; Branscum, Adam J
2013-11-30
Many commonly used models for linear regression analysis force overly simplistic shape and scale constraints on the residual structure of data. We propose a semiparametric Bayesian model for regression analysis that produces data-driven inference by using a new type of dependent Polya tree prior to model arbitrary residual distributions that are allowed to evolve across increasing levels of an ordinal covariate (e.g., time, in repeated measurement studies). By modeling residual distributions at consecutive covariate levels or time points using separate, but dependent Polya tree priors, distributional information is pooled while allowing for broad pliability to accommodate many types of changing residual distributions. We can use the proposed dependent residual structure in a wide range of regression settings, including fixed-effects and mixed-effects linear and nonlinear models for cross-sectional, prospective, and repeated measurement data. A simulation study illustrates the flexibility of our novel semiparametric regression model to accurately capture evolving residual distributions. In an application to immune development data on immunoglobulin G antibodies in children, our new model outperforms several contemporary semiparametric regression models based on a predictive model selection criterion. Copyright © 2013 John Wiley & Sons, Ltd.
Repeat immigration: A previously unobserved source of heterogeneity?
Aradhya, Siddartha; Scott, Kirk; Smith, Christopher D
2017-07-01
Register data allow for nuanced analyses of heterogeneities between sub-groups which are not observable in other data sources. One heterogeneity for which register data is particularly useful is in identifying unique migration histories of immigrant populations, a group of interest across disciplines. Years since migration is a commonly used measure of integration in studies seeking to understand the outcomes of immigrants. This study constructs detailed migration histories to test whether misclassified migrations may mask important heterogeneities. In doing so, we identify a previously understudied group of migrants called repeat immigrants, and show that they differ systematically from permanent immigrants. In addition, we quantify the degree to which migration information is misreported in the registers. The analysis is carried out in two steps. First, we estimate income trajectories for repeat immigrants and permanent immigrants to understand the degree to which they differ. Second, we test data validity by cross-referencing migration information with changes in income to determine whether there are inconsistencies indicating misreporting. From the first part of the analysis, the results indicate that repeat immigrants systematically differ from permanent immigrants in terms of income trajectories. Furthermore, income trajectories differ based on the way in which years since migration is calculated. The second part of the analysis suggests that misreported migration events, while present, are negligible. Repeat immigrants differ in terms of income trajectories, and may differ in terms of other outcomes as well. Furthermore, this study underlines that Swedish registers provide a reliable data source to analyze groups which are unidentifiable in other data sources.
Redditi Hanzlik, J
1989-01-01
An intervention study designed to investigate the effects of one hour of maternal and infant behavior was conducted using experimental and control groups of mothers and their infants with cerebral palsy. Ten mother-infant pairs were in each group; infants ranged in age from 8-32 months. Infants of mothers in the control group received one hour of NDT-based occupational therapy. Two-factor repeated measures analysis of variance with repeated measures of the second factor indicated that the nonverbal instruction methods were significantly more successful in modifying maternal and infant behavior than were the verbal instruction methods. Implications of the results for intervention programs and future research were discussed.
The Motivating Influence of Retest and Repeated Dietary Counseling on Cholesterol Reduction
NASA Technical Reports Server (NTRS)
Taylor, P.; Townsend, J. C.; Villafana, C.; Arnoldi, L. B.
1971-01-01
An analysis was made of retest and followup counselling effects on the reduction of hypercholesterolemia levels in NASA employees. Criteria used to measure such control include motivation, age of patient, personality of patient, job stress, and physical exercise.
Bian, Lin
2012-01-01
In clinical practice, hearing thresholds are measured at only five to six frequencies at octave intervals. Thus, the audiometric configuration cannot closely reflect the actual status of the auditory structures. In addition, differential diagnosis requires quantitative comparison of behavioral thresholds with physiological measures, such as otoacoustic emissions (OAEs) that are usually measured in higher resolution. The purpose of this research was to develop a method to improve the frequency resolution of the audiogram. A repeated-measure design was used in the study to evaluate the reliability of the threshold measurements. A total of 16 participants with clinically normal hearing and mild hearing loss were recruited from a population of university students. No intervention was involved in the study. Custom developed system and software were used for threshold acquisition with quality control (QC). With real-ear calibration and monitoring of test signals, the system provided accurate and individualized measure of hearing thresholds that were determined by an analysis based on signal detection theory (SDT). The reliability of the threshold measure was assessed by correlation and differences between the repeated measures. The audiometric configurations were diverse and unique to each individual ear. The accuracy, within-subject reliability, and between-test repeatability are relatively high. With QC, the high-resolution audiograms can be reliably and accurately measured. Hearing thresholds measured as ear canal sound pressures with higher frequency resolution can provide more customized hearing-aid fitting. The test system may be integrated with other physiological measures, such as OAEs, into a comprehensive evaluative tool. American Academy of Audiology.
Tackenberg, Oliver
2007-01-01
Background and Aims Biomass is an important trait in functional ecology and growth analysis. The typical methods for measuring biomass are destructive. Thus, they do not allow the development of individual plants to be followed and they require many individuals to be cultivated for repeated measurements. Non-destructive methods do not have these limitations. Here, a non-destructive method based on digital image analysis is presented, addressing not only above-ground fresh biomass (FBM) and oven-dried biomass (DBM), but also vertical biomass distribution as well as dry matter content (DMC) and growth rates. Methods Scaled digital images of the plants silhouettes were taken for 582 individuals of 27 grass species (Poaceae). Above-ground biomass and DMC were measured using destructive methods. With image analysis software Zeiss KS 300, the projected area and the proportion of greenish pixels were calculated, and generalized linear models (GLMs) were developed with destructively measured parameters as dependent variables and parameters derived from image analysis as independent variables. A bootstrap analysis was performed to assess the number of individuals required for re-calibration of the models. Key Results The results of the developed models showed no systematic errors compared with traditionally measured values and explained most of their variance (R2 ≥ 0·85 for all models). The presented models can be directly applied to herbaceous grasses without further calibration. Applying the models to other growth forms might require a re-calibration which can be based on only 10–20 individuals for FBM or DMC and on 40–50 individuals for DBM. Conclusions The methods presented are time and cost effective compared with traditional methods, especially if development or growth rates are to be measured repeatedly. Hence, they offer an alternative way of determining biomass, especially as they are non-destructive and address not only FBM and DBM, but also vertical biomass distribution and DMC. PMID:17353204
Thorn, Stephanie L; deKemp, Robert A; Dumouchel, Tyler; Klein, Ran; Renaud, Jennifer M; Wells, R Glenn; Gollob, Michael H; Beanlands, Rob S; DaSilva, Jean N
2013-09-01
A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.
Contribution to the benchmark for ternary mixtures: Transient analysis in microgravity conditions.
Ahadi, Amirhossein; Ziad Saghir, M
2015-04-01
We present a transient experimental analysis of the DCMIX1 project conducted onboard the International Space Station for a ternary tetrahydronaphtalene, isobutylbenzene, n-dodecane mixture. Raw images taken in microgravity environment using the SODI (Selectable Optical Diagnostic) apparatus which is equipped with two wavelength diagnostic were processed and the results were analyzed in this work. We measured the concentration profile of the mixture containing 80% THN, 10% IBB and 10% nC12 during the entire experiment using an advanced image processing technique and accordingly we determined the Soret coefficients using an advanced curve-fitting and post-processing technique. It must be noted that the experiment has been repeated five times to ensure the repeatability of the experiment.
Amano, Shiro; Honda, Norihiko; Amano, Yuki; Yamagami, Satoru; Miyai, Takashi; Samejima, Tomokazu; Ogata, Miyuki; Miyata, Kazunori
2006-06-01
To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Experimental study. Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.
NASA Astrophysics Data System (ADS)
Singletary, Joanna Lynn Bush
This study evaluated the relationship of environmental service-learning on environmental literacy in undergraduates. The subjects were 36 undergraduates at a small liberal arts university enrolled in an environmental biology course. To determine the role of environmental service-learning on college students' environmental knowledge, attitudes, behaviors, and environmental literacy, this study utilized concurrent mixed methods approach for qualitative and quantitative analysis. A quasi-experimental repeated measures approach was the design of the quantitative component of the study. Data were collected on attitude, behavior, and content knowledge aspects of environmental literacy as measured by the Environmental Literacy Survey (Kibert, 2000). Hypotheses were tested by independent samples ttests and repeated measures ANOVA. Repeated measures ANOVA conducted on participants' three subscales scores for the Environmental Literacy Survey (attitude, behavior, and knowledge) indicated that students who participated in environmental service-learning scored statistically significantly higher than those that did not initially participate in service-learning. Qualitative data collected in the form of journal reflections and portfolios were evaluated for themes of environmental attitudes or affective statements, environmentally positive behaviors and skills, and ecological content. Quantitative and qualitative data support the positive role of environmental service-learning in the development of environmental literacy in undergraduate students.
Darveau, Charles-A; Billardon, Fannie; Bélanger, Kasandra
2014-02-15
The evolution of flight energetics requires that phenotypes be variable, repeatable and heritable. We studied intraspecific variation in flight energetics in order to assess the repeatability of flight metabolic rate and wingbeat frequency, as well as the functional basis of phenotypic variation in workers and drones of the bumblebee species Bombus impatiens. We showed that flight metabolic rate and wingbeat frequency were highly repeatable in workers, even when controlling for body mass variation using residual analysis. We did not detect significant repeatability in drones, but a smaller range of variation might have prevented us from finding significant values in our sample. Based on our results and previous findings, we associated the high repeatability of flight phenotypes in workers to the functional links between body mass, thorax mass, wing size, wingbeat frequency and metabolic rate. Moreover, differences between workers and drones were as predicted from these functional associations, where drones had larger wings for their size, lower wingbeat frequency and lower flight metabolic rate. We also investigated thoracic muscle metabolic phenotypes by measuring the activity of carbohydrate metabolism enzymes, and we found positive correlations between mass-independent metabolic rate and the activity of all enzymes measured, but in workers only. When comparing workers and drones that differ in flight metabolic rate, only the activity of the enzymes hexokinase and trehalase showed the predicted differences. Overall, our study indicates that there should be correlated evolution among physiological phenotypes at multiple levels of organization and morphological traits associated with flight.
40 CFR 1065.12 - Approval of alternate procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engine meets all applicable emission standards according to specified procedures. (iii) Use statistical.... (e) We may give you specific directions regarding methods for statistical analysis, or we may approve... statistical tests. Perform the tests as follows: (1) Repeat measurements for all applicable duty cycles at...
Residual Structures in Latent Growth Curve Modeling
ERIC Educational Resources Information Center
Grimm, Kevin J.; Widaman, Keith F.
2010-01-01
Several alternatives are available for specifying the residual structure in latent growth curve modeling. Two specifications involve uncorrelated residuals and represent the most commonly used residual structures. The first, building on repeated measures analysis of variance and common specifications in multilevel models, forces residual variances…
NASA Technical Reports Server (NTRS)
Christianson, R. C.; Kaushik, Surender M.; Davis, Dennis D.
1995-01-01
Device breaks glass ampoule in repeatable manner and retains gaseous content so pressure of gas measured accurately. In addition, protects technician from gaseous contents, which can be hazardous. Broken glass and sample materials easily removed for disposal or analysis. Apparatus developed for use in experiments on compatibility of materials.
A Challenge to Improve High-Temperature Platinum Resistance Thermometer
NASA Astrophysics Data System (ADS)
Tanaka, Y.; Widiatmo, J. V.; Harada, K.; Kobayashi, T.; Yamazawa, K.
2017-05-01
High-temperature standard platinum resistance thermometers (HTSPRTs) are used to interpolate the international temperature scale of 1990 (ITS-90), especially for temperatures between the aluminum and the silver points. For this, long-term stability of the HTSPRT is essential. CHINO R800-3L type SPRT, which has a nominal resistance at the triple point of water (TPW) around 0.25 Ω , is the one developed earlier for the interpolation of the ITS-90 at this temperature range. Further development to this previous model has been carried out for the purpose of improving the thermal stability. The improvement was focused on reducing the effect coming from the difference in thermal expansion between platinum wire and the quartz frame on which the platinum wire is installed. New HTSPRTs were made by CHINO Corporation. Some series of tests were carried out at CHINO and at NMIJ. Initial tests after the HTSPRT fabrication were done at CHINO, where thermal cycles between 500°C and 980°C were applied to the HTSPRTs to see change in the resistances at the TPW (R_{TPW}) and at the gallium point (R_{Ga}). Repeated resistance measurements at the silver point (R_{Ag}) were performed after completing the thermal cycling test. Before and after every measurement at silver point, R_{TPW} was measured, while before and after every two silver point realization R_{Ga} were measured. After completing this test, the HTSPRTs were transported to NMIJ, where the same repeated measurements at the silver point were done at NMIJ. These were then repeated at CHINO and at NMIJ upon repeated transportation among the institutes, to evaluate some effect due to transportation. This paper reports the details of the above-mentioned tests, the results and the analysis.
Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software.
Lopez, Natalia; Perez, Elisa; Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E
2018-01-01
The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established goniometric methods determines that the proposed software agrees sufficiently to be used interchangeably.
Evaluation of the Repeatability and Accuracy of the Wideband Real-Ear-to-Coupler Difference.
Vaisberg, Jonathan M; Folkeard, Paula; Pumford, John; Narten, Philipp; Scollie, Susan
2018-06-01
The real-ear-to-coupler difference (RECD) is an ANSI standardized method for estimating ear canal sound pressure level (SPL) thresholds and assisting in the prediction of real-ear aided responses. It measures the difference in dB between the SPL produced in the ear canal and the SPL produced in an HA-1 2-cc coupler by the same sound source. Recent evidence demonstrates that extended high-frequency bandwidth, beyond the hearing aid bandwidth typically measured, is capable of providing additional clinical benefit. The industry has, in turn, moved toward developing hearing aids and verification equipment capable of producing and measuring extended high-frequency audible output. As a result, a revised RECD procedure conducted using a smaller, 0.4-cc coupler, known as the wideband-RECD (wRECD), has been introduced to facilitate extended high-frequency coupler-based measurements up to 12.5 kHz. This study aimed to (1) compare test-retest repeatability between the RECD and wRECD and (2) measure absolute agreement between the RECD and wRECD when both are referenced to a common coupler. RECDs and wRECDs were measured bilaterally in adult ears by calculating the dB difference in SPL between the ear canal and coupler responses. Real-ear probe microphone measures were completed twice per ear per participant for both foam-tip and customized earmold couplings using the Audioscan Verifit 1 and Verifit 2 fitting systems, followed by measurements in the respective couplers. Twenty-one adults (mean age = 67 yr, range = 19-78) with typical aural anatomy (as determined by measures of impedance and otoscopy) participated in this study, leading to a sample size of 42 ears. Repeatability within RECD and wRECD was assessed for each coupling configuration using a repeated-measures analysis of variance (ANOVA) with test-retest and frequency as within-participants factors. Repeatability between the RECD and wRECD was assessed within each configuration using a repeated-measures ANOVA with test-retest, frequency, and coupler type as within-participants factors. Agreement between the RECD and wRECD was assessed for each coupling configuration using a repeated-measures ANOVA with RECD value, coupler type, and frequency as within-participants factors. Post hoc comparisons with Bonferroni corrections were used when appropriate to locate the frequencies at which differences occurred. A 3-dB criterion was defined to locate differences of clinical significance. Average absolute test-retest differences were within ±3 dB within each coupler and coupling configuration, and between the RECD and wRECD. The RECD and wRECD were in absolute agreement following HA-1-referenced transforms, with most frequencies agreeing within ±1 dB, except at 0.2 kHz for the earmold, and 0.2-0.25 kHz for the foam tip, where the average RECD exceeded the average wRECD by slightly >3 dB. Test-retest repeatability of the RECD (up to 8 kHz) and wRECD (up to 12.5 kHz) is acceptable and similar to previously reported data. The RECD and wRECD are referenced to different couplers, but can be rendered comparable with a simple transform, producing values that are in accordance with the ANSI S3.46-2013 standard. American Academy of Audiology.
Application of Regression-Discontinuity Analysis in Pharmaceutical Health Services Research
Zuckerman, Ilene H; Lee, Euni; Wutoh, Anthony K; Xue, Zhenyi; Stuart, Bruce
2006-01-01
Objective To demonstrate how a relatively underused design, regression-discontinuity (RD), can provide robust estimates of intervention effects when stronger designs are impossible to implement. Data Sources/Study Setting Administrative claims from a Mid-Atlantic state Medicaid program were used to evaluate the effectiveness of an educational drug utilization review intervention. Study Design Quasi-experimental design. Data Collection/Extraction Methods A drug utilization review study was conducted to evaluate a letter intervention to physicians treating Medicaid children with potentially excessive use of short-acting β2-agonist inhalers (SAB). The outcome measure is change in seasonally-adjusted SAB use 5 months pre- and postintervention. To determine if the intervention reduced monthly SAB utilization, results from an RD analysis are compared to findings from a pretest–posttest design using repeated-measure ANOVA. Principal Findings Both analyses indicated that the intervention significantly reduced SAB use among the high users. Average monthly SAB use declined by 0.9 canisters per month (p<.001) according to the repeated-measure ANOVA and by 0.2 canisters per month (p<.001) from RD analysis. Conclusions Regression-discontinuity design is a useful quasi-experimental methodology that has significant advantages in internal validity compared to other pre–post designs when assessing interventions in which subjects' assignment is based on cutoff scores for a critical variable. PMID:16584464
Krishnamurthy, Gerbail T; Krishnamurthy, Shakuntala; Gambhir, Sanjiv Sam; Rodrigues, Cesar; Rosenberg, Jarrett; Schiepers, Christiaan; Buxton-Thomas, Muriel
2009-12-01
To develop a software tool for quantification of liver and gallbladder function, and to assess the repeatability and reproducibility of measurements made with it. The software tool developed with the JAVA programming language uses the JAVA2 Standard Edition framework. After manual selection of the regions of interest on a 99mTc hepatic iminodiacetic acid study, the program calculates differential hepatic bile flow, basal duodeno-gastric bile reflux (B-DGBR), hepatic extraction fraction (HEF) of both the lobes with deconvolutional analysis and excretion half-time with nonlinear least squares fit. Gallbladder ejection fraction, ejection period (EP), ejection rate (ER), and postcholecystokinin (CCK) DGBR are calculated after stimulation with CCK-8. To assess intra-observer repeatability and intra-observer reproducibility, measurements from 10 normal participants were analyzed twice by three nuclear medicine technologists at the primary center. To assess inter-site reproducibility, measurements from a superset of 24 normal participants were also assessed once by three observers at the primary center and single observer at three other sites. For the 24 control participants, mean+/-SD of hepatic bile flow into gallbladder was 63.87+/-28.7%, HEF of the right lobe 100+/-0%, left lobe 99.43+2.63%, excretion half-time of the right lobe 21.50+6.98 min, left lobe 28.3+/-11.3 min. Basal DGBR was 1.2+/-1.0%. Gallbladder ejection fraction was 80+/-11%, EP 15.0+/-3.0 min, ER 5.8+/-1.6%/min, and DGBR-CCK 1.3+/-2.3%. Left and right lobe HEF was virtually identical across readers. All measures showed high repeatability except for gallbladder bile flow, basal DGBR, and EP, which exhibited marginal repeatability. Ejection fraction exhibited high reproducibility. There was high concordance among the three primary center observers except for basal DGBR, EP, and ER. Concordance between the primary site and one of the other sites was high, one was fair, and one was poor. New United States Food and Drug Administration-approved personal computer-based Krishnamurthy Hepato-Biliary Software for quantification of the liver and gallbladder function shows promise for consistently repeatable and reproducible results both within and between institutions, and may help to promote universal standardization of data acquisition and analysis in nuclear hepatology.
About-face on face recognition ability and holistic processing
Richler, Jennifer J.; Floyd, R. Jackie; Gauthier, Isabel
2015-01-01
Previous work found a small but significant relationship between holistic processing measured with the composite task and face recognition ability measured by the Cambridge Face Memory Test (CFMT; Duchaine & Nakayama, 2006). Surprisingly, recent work using a different measure of holistic processing (Vanderbilt Holistic Face Processing Test [VHPT-F]; Richler, Floyd, & Gauthier, 2014) and a larger sample found no evidence for such a relationship. In Experiment 1 we replicate this unexpected result, finding no relationship between holistic processing (VHPT-F) and face recognition ability (CFMT). A key difference between the VHPT-F and other holistic processing measures is that unique face parts are used on each trial in the VHPT-F, unlike in other tasks where a small set of face parts repeat across the experiment. In Experiment 2, we test the hypothesis that correlations between the CFMT and holistic processing tasks are driven by stimulus repetition that allows for learning during the composite task. Consistent with our predictions, CFMT performance was correlated with holistic processing in the composite task when a small set of face parts repeated over trials, but not when face parts did not repeat. A meta-analysis confirms that relationships between the CFMT and holistic processing depend on stimulus repetition. These results raise important questions about what is being measured by the CFMT, and challenge current assumptions about why faces are processed holistically. PMID:26223027
About-face on face recognition ability and holistic processing.
Richler, Jennifer J; Floyd, R Jackie; Gauthier, Isabel
2015-01-01
Previous work found a small but significant relationship between holistic processing measured with the composite task and face recognition ability measured by the Cambridge Face Memory Test (CFMT; Duchaine & Nakayama, 2006). Surprisingly, recent work using a different measure of holistic processing (Vanderbilt Holistic Face Processing Test [VHPT-F]; Richler, Floyd, & Gauthier, 2014) and a larger sample found no evidence for such a relationship. In Experiment 1 we replicate this unexpected result, finding no relationship between holistic processing (VHPT-F) and face recognition ability (CFMT). A key difference between the VHPT-F and other holistic processing measures is that unique face parts are used on each trial in the VHPT-F, unlike in other tasks where a small set of face parts repeat across the experiment. In Experiment 2, we test the hypothesis that correlations between the CFMT and holistic processing tasks are driven by stimulus repetition that allows for learning during the composite task. Consistent with our predictions, CFMT performance was correlated with holistic processing in the composite task when a small set of face parts repeated over trials, but not when face parts did not repeat. A meta-analysis confirms that relationships between the CFMT and holistic processing depend on stimulus repetition. These results raise important questions about what is being measured by the CFMT, and challenge current assumptions about why faces are processed holistically.
[Influence of repeated sintering on the color of two brands of porcelain-fused-to-titanium].
Shu, Cheng-jun; Luo, Xiao-ping; Wu, Lie
2007-08-01
To investigate the influence of repeated sintering on the color of two porcelain-fused-to-titanium, and the differences between the two porcelains. Thirty samples were prepared and sintered for 9 times. The color of samples were measured following sintering 1, 3, 5, 7, 9 times by ShadeEye NCC colorimeter according to two brands of porcelains with CIE1976L*a*b* color system, and calculated relevant chrome, chromatism and hue, and statistical analysis. When two brands of porcelains were sintered 5 times, the color parameters had no significant change and sintered continuely, the color parameters of L* and a* had obvious changes, but can't be observed by eyes. The color parameters of titanium-porcelains have no significant change after repeated sintering.
Clinical evaluation of a dental color analysis system: the Crystaleye Spectrophotometer®.
Odaira, Chikayuki; Itoh, Sozo; Ishibashi, Kanji
2011-10-01
To evaluate the clinical performance of the Crystaleye Spectrophotometer(®), a dental color analysis system. Three color-measuring devices (Crystaleye Spectrophotometer(®), CAS-ID1, MSC-2000) were tested and the differences in color measurements among them were evaluated using Scheffe's F-test. Color measurements with the Crystaleye Spectrophotometer(®) were repeated 10 times by the same operator. The color difference (ΔE) between the first and tenth measurements was calculated. The Crystaleye Spectrophotometer(®) was used to measure the color of the maxillary left central incisor under two conditions (light and dark) and the effect of exterior lighting was analyzed to assess the accuracy of measurements. Furthermore, five different operators performed color measurements, and ΔE among the three devices was calculated. The ΔE between the target tooth and the crown of a single maxillary central incisor crown fabricated using data from the Crystaleye Spectrophotmeter(®) was calculated. Color differences between prebleaching and postbleaching were also analyzed with the Crystaleye Spectrophotometer(®) using the parameters ΔE, ΔL*, Δa*, and Δb*. The data from the three spectrophotometers were not significantly different. The ΔE during repeated color measurements by the same operator was 0.6. The ΔE between light and dark conditions was 0.9. The data from the five operators were not significantly different. The mean ΔE value between the target tooth and the fabricated crown was 1.2 ± 0.4, and the mean ΔE value between prebleaching and postbleaching was 3.7 ± 1.0. The Crystaleye Spectrophotometer(®) is an easy-to-use color analysis system producing accurate color measurements under clinical conditions. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Terahertz transmission properties of silicon wafers using continuous-wave terahertz spectroscopy
NASA Astrophysics Data System (ADS)
Kim, Chihoon; Ahn, Jae Sung; Ji, Taeksoo; Eom, Joo Beom
2017-04-01
We present the spectral properties of Si wafers using continuous-wave terahertz (CW-THz) spectroscopy. By using a tunable laser source and a fixed distributed-feedback laser diode (DFB-LD), a stably tunable beat source for CW-THz spectroscopy system can be implemented. THz radiation is generated in the frequency range of 100 GHz-800 GHz by photomixing in a photoconductive antenna. We also measured CW-THz waveforms by changing the beat frequency and confirmed repeatability through repeated measurement. We calculated the peaks of the THz frequency by taking fast Fourier transforms (FFTs) of measured THz waveforms. The feasibility of CW-THz spectroscopy is demonstrated by the THz spectra of Si wafers with different resistivities, mobilities, and carrier concentrations. The results show that Si wafers with a lower resistivity absorb more THz waves. Thus, we expect our CW-THz system to have the advantage of being able to perform fast non-destructive analysis.
Construction of Gallium Point at NMIJ
NASA Astrophysics Data System (ADS)
Widiatmo, J. V.; Saito, I.; Yamazawa, K.
2017-03-01
Two open-type gallium point cells were fabricated using ingots whose nominal purities are 7N. Measurement systems for the realization of the melting point of gallium using these cells were built. The melting point of gallium is repeatedly realized by means of the measurement systems for evaluating the repeatability. Measurements for evaluating the effect of hydrostatic pressure coming from the molten gallium existing during the melting process and the effect of gas pressure that fills the cell were also performed. Direct cell comparisons between those cells were conducted. This comparison was aimed to evaluate the consistency of each cell, especially related to the nominal purity. Direct cell comparison between the open-type and the sealed-type gallium point cell was also conducted. Chemical analysis was conducted using samples extracted from ingots used in both the newly built open-type gallium point cells, from which the effect of impurities in the ingot was evaluated.
ERIC Educational Resources Information Center
Chedester, Cheryl G. Moore
2012-01-01
Using an equal-group stratified sample of 42 Kentucky public P-12 school districts, the researcher conducted a quantitative correlational analysis to examine the relationship between per pupil expenditures in reading and mathematics proficiency. Repeated measures t tests analyzed the differences of the mean scores for the study variables of…
Telomere Restriction Fragment (TRF) Analysis.
Mender, Ilgen; Shay, Jerry W
2015-11-20
While telomerase is expressed in ~90% of primary human tumors, most somatic tissue cells except transiently proliferating stem-like cells do not have detectable telomerase activity (Shay and Wright, 1996; Shay and Wright, 2001). Telomeres progressively shorten with each cell division in normal cells, including proliferating stem-like cells, due to the end replication (lagging strand synthesis) problem and other causes such as oxidative damage, therefore all somatic cells have limited cell proliferation capacity (Hayflick limit) (Hayflick and Moorhead, 1961; Olovnikov, 1973). The progressive telomere shortening eventually leads to growth arrest in normal cells, which is known as replicative senescence (Shay et al. , 1991). Once telomerase is activated in cancer cells, telomere length is stabilized by the addition of TTAGGG repeats to the end of chromosomes, thus enabling the limitless continuation of cell division (Shay and Wright, 1996; Shay and Wright, 2001). Therefore, the link between aging and cancer can be partially explained by telomere biology. There are many rapid and convenient methods to study telomere biology such as Telomere Restriction Fragment (TRF), Telomere Repeat Amplification Protocol (TRAP) (Mender and Shay, 2015b) and Telomere dysfunction Induced Foci (TIF) analysis (Mender and Shay, 2015a). In this protocol paper we describe Telomere Restriction Fragment (TRF) analysis to determine average telomeric length of cells. Telomeric length can be indirectly measured by a technique called Telomere Restriction Fragment analysis (TRF). This technique is a modified Southern blot, which measures the heterogeneous range of telomere lengths in a cell population using the length distribution of the terminal restriction fragments (Harley et al. , 1990; Ouellette et al. , 2000). This method can be used in eukaryotic cells. The description below focuses on the measurement of human cancer cells telomere length. The principle of this method relies on the lack of restriction enzyme recognition sites within TTAGGG tandem telomeric repeats, therefore digestion of genomic DNA, not telomeric DNA, with a combination of 6 base restriction endonucleases reduces genomic DNA size to less than 800 bp.
Auto-tracking system for human lumbar motion analysis.
Sui, Fuge; Zhang, Da; Lam, Shing Chun Benny; Zhao, Lifeng; Wang, Dongjun; Bi, Zhenggang; Hu, Yong
2011-01-01
Previous lumbar motion analyses suggest the usefulness of quantitatively characterizing spine motion. However, the application of such measurements is still limited by the lack of user-friendly automatic spine motion analysis systems. This paper describes an automatic analysis system to measure lumbar spine disorders that consists of a spine motion guidance device, an X-ray imaging modality to acquire digitized video fluoroscopy (DVF) sequences and an automated tracking module with a graphical user interface (GUI). DVF sequences of the lumbar spine are recorded during flexion-extension under a guidance device. The automatic tracking software utilizing a particle filter locates the vertebra-of-interest in every frame of the sequence, and the tracking result is displayed on the GUI. Kinematic parameters are also extracted from the tracking results for motion analysis. We observed that, in a bone model test, the maximum fiducial error was 3.7%, and the maximum repeatability error in translation and rotation was 1.2% and 2.6%, respectively. In our simulated DVF sequence study, the automatic tracking was not successful when the noise intensity was greater than 0.50. In a noisy situation, the maximal difference was 1.3 mm in translation and 1° in the rotation angle. The errors were calculated in translation (fiducial error: 2.4%, repeatability error: 0.5%) and in the rotation angle (fiducial error: 1.0%, repeatability error: 0.7%). However, the automatic tracking software could successfully track simulated sequences contaminated by noise at a density ≤ 0.5 with very high accuracy, providing good reliability and robustness. A clinical trial with 10 healthy subjects and 2 lumbar spondylolisthesis patients were enrolled in this study. The measurement with auto-tacking of DVF provided some information not seen in the conventional X-ray. The results proposed the potential use of the proposed system for clinical applications.
NASA Astrophysics Data System (ADS)
Haller, John W.; Botteron, K.; Brunsden, Barry S.; Sheline, Yvette I.; Walkup, Ronald K.; Black, Kevin J.; Gado, Mokhtar; Vannier, Michael W.
1994-09-01
Goal: To estimate hippocampal volumes from in vivo 3D magnetic resonance (MR) brain images and determine inter-rater and intra- rater repeatability. Objective: The precision and repeatability of hippocampal volume estimates using stereologic measurement methods is sought. Design: Five normal control and five schizophrenic subjects were MR scanned using a MPRAGE protocol. Fixed grid stereologic methods were used to estimate hippocampal volumes on a graphics workstation. The images were preprocessed using histogram analysis to standardize 3D MR image scaling from 16 to 8 bits and image volumes were interpolated to 0.5 mm3 isotropic voxels. The following variables were constant for the repeated stereologic measures: grid size, inter-slice distance (1.5 mm), voxel dimensions (0.5 mm3), number of hippocampi measured (10), total number of measurements per rater (40), and number of raters (5). Two grid sizes were tested to determine the coefficient of error associated with the number of sampled 'hits' (approximately 140 and 280) on the hippocampus. Starting slice and grid position were randomly varied to assure unbiased volume estimates. Raters were blind to subject identity, diagnosis, and side of the brain from which the image volumes were extracted and the order of subject presentation was randomized for each of the raters. Inter- and intra-rater intraclass correlation coefficients (ICC) were determined. Results: The data indicate excellent repeatability of fixed grid stereologic hippocampal volume measures when using an inter-slice distance of 1.5 mm and a 6.25 mm2 grid (inter-rater ICCs equals 0.86 - 0.97, intra- rater ICCs equals 0.85 - 0.97). One major advantage of the current study was the use of 3D MR data which significantly improved visualization of hippocampal boundaries by providing the ability to access simultaneous orthogonal views while counting stereological marks within the hippocampus. Conclusion: Stereological estimates of 3D volumes from 2D MR sections provide an inexpensive, unbiased and efficient way of determining brain structural volumes. The high precision and repeatability demonstrated with stereological MR volumetry suggest that these methods may be efficiently used to measure small volume reductions associated with schizophrenia and other brain disorders.
Sharma, Ashish; Oakley, Jonathan D.; Schiffman, Joyce C.; Budenz, Donald L.; Anderson, Douglas R.
2010-01-01
OBJECTIVE To evaluate a new automated analysis of optic disc images obtained by spectral domain optical coherence tomography (SD-OCT). Areas of the optic disc, cup, and neural rim in SD-OCT images were compared with these areas from stereoscopic photographs, to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN Evaluation of diagnostic technology. PARTICIPANTS 119 healthy eyes, 23 eyes with glaucoma, and 7 suspect eyes METHODS Optic disc and cup margins were traced from stereoscopic photographs by three individuals independently. Optic disc margins and rim widths were determined automatically in SD-OCT. A subset of photographs was examined and traced a second time, and duplicate SD-OCT images were also analyzed. MAIN OUTCOME MEASUREMENTS Agreement among photograph readers, between duplicate readings, and between SD-OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square (RMS), and the standard deviation (SD) of the differences. RESULTS Optic disc areas tended to be slightly larger when judged in photographs than by SD-OCT, while cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between average photographic reading and SD-OCT, but only fair correlation of rim areas (0.4). The SD-OCT was highly reproducible (ICC of 0.96 to 0.99). Each reader was also consistent with himself on duplicate readings of 21 photographs (ICC 0.80 to 0.88 for rim area, 0.95 to 0.98 for all other measurements), but reproducibility was not as good as SD-OCT. Measurements derived from SD-OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS Designation of the cup and optic disc boundaries by an automated analysis of SD-OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD-OCT than from among readers of photographs. The repeatability of automated measurement of SD-OCT images is promising for use both in diagnosis and in monitoring of progression. PMID:21397334
Repeatability Evaluation of a Contrast Sensitivity System for Transfer to the Eye Clinic
NASA Astrophysics Data System (ADS)
Alcalde, N. G.; Castillo, L. R.; Filgueira, C. Paz; Colombo, E. M.
2016-04-01
The Contrast Sensitivity Function (CSF) is a valuable tool which can be used to characterize functional vision and also for the diagnosis and management of patients with different eye diseases. In spite of its usefulness, the CSF is currently hardly ever used in clinical practice. The aim of this study was to validate the use of the system called FVC-100 (Tecnovinc-UNT-CONICET, Argentina), which calculates the CSF, in order to transfer this important tool to ophthalmological clinics. The validation was carried out through the design of a repeatability test and the subsequent analysis of the results. Furthermore, we evaluated the impact of different factors influencing the repeatability of the measurements such as age and previous training. The tests were based on the discrimination of sinusoidal gratings for different spatial frequencies (1, 4 and 12 c/°) in both eyes of 12 people, aged between 20 and 70. The results show that the calculated values of SC of each subject have a high repeatability and are not dependent on age or training. These results allow us to conclude positively regarding the effectiveness of the FVC-100, and to validate its use in clinics for the calculation of the FSC as a standard measure of functional vision quality.
Juárez, M; Polvillo, O; Contò, M; Ficco, A; Ballico, S; Failla, S
2008-05-09
Four different extraction-derivatization methods commonly used for fatty acid analysis in meat (in situ or one-step method, saponification method, classic method and a combination of classic extraction and saponification derivatization) were tested. The in situ method had low recovery and variation. The saponification method showed the best balance between recovery, precision, repeatability and reproducibility. The classic method had high recovery and acceptable variation values, except for the polyunsaturated fatty acids, showing higher variation than the former methods. The combination of extraction and methylation steps had great recovery values, but the precision, repeatability and reproducibility were not acceptable. Therefore the saponification method would be more convenient for polyunsaturated fatty acid analysis, whereas the in situ method would be an alternative for fast analysis. However the classic method would be the method of choice for the determination of the different lipid classes.
Liu, Hon-Man; Chen, Shan-Kai; Chen, Ya-Fang; Lee, Chung-Wei; Yeh, Lee-Ren
2016-01-01
Purpose To assess the inter session reproducibility of automatic segmented MRI-derived measures by FreeSurfer in a group of subjects with normal-appearing MR images. Materials and Methods After retrospectively reviewing a brain MRI database from our institute consisting of 14,758 adults, those subjects who had repeat scans and had no history of neurodegenerative disorders were selected for morphometry analysis using FreeSurfer. A total of 34 subjects were grouped by MRI scanner model. After automatic segmentation using FreeSurfer, label-wise comparison (involving area, thickness, and volume) was performed on all segmented results. An intraclass correlation coefficient was used to estimate the agreement between sessions. Wilcoxon signed rank test was used to assess the population mean rank differences across sessions. Mean-difference analysis was used to evaluate the difference intervals across scanners. Absolute percent difference was used to estimate the reproducibility errors across the MRI models. Kruskal-Wallis test was used to determine the across-scanner effect. Results The agreement in segmentation results for area, volume, and thickness measurements of all segmented anatomical labels was generally higher in Signa Excite and Verio models when compared with Sonata and TrioTim models. There were significant rank differences found across sessions in some labels of different measures. Smaller difference intervals in global volume measurements were noted on images acquired by Signa Excite and Verio models. For some brain regions, significant MRI model effects were observed on certain segmentation results. Conclusions Short-term scan-rescan reliability of automatic brain MRI morphometry is feasible in the clinical setting. However, since repeatability of software performance is contingent on the reproducibility of the scanner performance, the scanner performance must be calibrated before conducting such studies or before using such software for retrospective reviewing. PMID:26812647
How dynamic are ice-stream beds?
NASA Astrophysics Data System (ADS)
Davies, Damon; Bingham, Robert G.; King, Edward C.; Smith, Andrew M.; Brisbourne, Alex M.; Spagnolo, Matteo; Graham, Alastair G. C.; Hogg, Anna E.; Vaughan, David G.
2018-05-01
Projections of sea-level rise contributions from West Antarctica's dynamically thinning ice streams contain high uncertainty because some of the key processes involved are extremely challenging to observe. An especially poorly observed parameter is sub-decadal stability of ice-stream beds, which may be important for subglacial traction, till continuity and landform development. Only two previous studies have made repeated geophysical measurements of ice-stream beds at the same locations in different years, but both studies were limited in spatial extent. Here, we present the results from repeat radar measurements of the bed of Pine Island Glacier, West Antarctica, conducted 3-6 years apart, along a cumulative ˜ 60 km of profiles. Analysis of the correlation of bed picks between repeat surveys shows that 90 % of the bed displays no significant change despite the glacier increasing in speed by up to 40 % over the last decade. We attribute the negligible detection of morphological change at the bed of Pine Island Glacier to the ubiquitous presence of a deforming till layer, wherein sediment transport is in steady state, such that sediment is transported along the basal interface without inducing morphological change to the radar-sounded basal interface. Given the precision of our measurements, the upper limit of subglacial erosion observed here is 500 mm a-1, far exceeding erosion rates reported for glacial settings from proglacial sediment yields, but substantially below subglacial erosion rates of 1.0 m a-1 previously reported from repeat geophysical surveys in West Antarctica.
Sims, A J; Reay, C A; Bousfield, D R; Menes, J A; Murray, A
2005-01-01
To measure the repeatability and pressure pulse envelope of simulators used for testing oscillometric non-invasive blood pressure (NIBP) devices; to study the effect of different envelopes on NIBP devices, and to measure the difference between NIBP devices due to different oscillometric algorithms. Three different models of NIBP simulator and 18 different patient monitors with NIBP function were studied. We developed a pressure measurement system (accuracy 0.048?mmHg) to measure the repeatability of simulators. The effect of changing the envelope was measured by using three simulators with one NIBP device. Differences between 18 NIBP devices were measured using one simulator at seven blood pressure settings. Simulators generate repeatable pressure pulse envelopes (< 0.2 mmHg) but the magnitude and shape depends on the model of simulator. Oscillometric NIBP devices are highly repeatable (< 2 mmHg) when presented with a repeatable pressure pulse envelope, but different devices employ different algorithms and give different results. For a simulated standard blood pressure setting of 120/80 mmHg, estimates of systolic pressure ranged from 112.6 to 126.6 mmHg (sd of 3.0 mmHg), and diastolic pressure ranged from 74.8 to 86.9 mmHg (sd of 3.5 mmHg). Simulators and NIBP devices are sufficiently repeatable for clinical use, but further systematic clinical studies are required to better characterize the pressure pulse envelope for different patient groups.
Effects of Repeated Treadmill Testing and Electrical Stimulation on Post-Stroke Gait Kinematics
Awad, Louis N.; Kesar, Trisha M.; Reisman, Darcy; Binder-Macleod, Stuart A.
2012-01-01
Improvements in task performance due to repeated testing have previously been documented in healthy and patient populations. The existence of a similar change in performance due to repeated testing has not been previously investigated at the level of gait kinematics in the post-stroke population. The presence of such changes may define the number of testing sessions necessary for measuring a stable baseline of pre-training gait performance, which is a necessary prerequisite for determining the effectiveness of gait interventions. Considering the emergence of treadmills as a popular tool for gait evaluation and retraining and the common addition of functional electrical stimulation (FES) to gait retraining protocols, the stability of gait kinematics during the repeated testing of post-stroke individuals on a treadmill, either with or without FES, needs to be determined. Nine individuals (age: 58.1 +/− 7.3 years), with hemi-paresis secondary to a stroke (onset: 7.3 +/− 6.0 years) participated in this study. An 8-camera motion analysis system was used to measure sagittal plane knee and ankle joint kinematics. Gait kinematics were compared across two (N=9) and five (N=5) testing sessions. No consistent changes in knee or ankle kinematics were observed during repeated testing. These findings indicate that clinicians and researchers may not need to spend valuable time and resources performing multiple testing and acclimatization sessions when assessing baseline gait kinematics in the post-stroke population for use in determining the effectiveness of gait interventions. PMID:22796242
Measurement System Analyses - Gauge Repeatability and Reproducibility Methods
NASA Astrophysics Data System (ADS)
Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej
2018-02-01
The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Role of IQGAP1 in Breast Carcinoma
2012-10-01
and"-tubulin expression was measured as described above. Statistical Analysis —All experiments were repeated inde- pendently at least three times...IQGAP1 Binds HER2—In vitro analysis with pure proteins was used to examine a possible interaction between IQGAP1 and HER2. GST alone or GST-HER2 was...incubated with puri- fied IQGAP1, and complexes were isolated with glutathione- Sepharose. Analysis by Western blotting reveals that IQGAP1 bindsHER2
Haverkamp, Nicolas; Beauducel, André
2017-01-01
We investigated the effects of violations of the sphericity assumption on Type I error rates for different methodical approaches of repeated measures analysis using a simulation approach. In contrast to previous simulation studies on this topic, up to nine measurement occasions were considered. Effects of the level of inter-correlations between measurement occasions on Type I error rates were considered for the first time. Two populations with non-violation of the sphericity assumption, one with uncorrelated measurement occasions and one with moderately correlated measurement occasions, were generated. One population with violation of the sphericity assumption combines uncorrelated with highly correlated measurement occasions. A second population with violation of the sphericity assumption combines moderately correlated and highly correlated measurement occasions. From these four populations without any between-group effect or within-subject effect 5,000 random samples were drawn. Finally, the mean Type I error rates for Multilevel linear models (MLM) with an unstructured covariance matrix (MLM-UN), MLM with compound-symmetry (MLM-CS) and for repeated measures analysis of variance (rANOVA) models (without correction, with Greenhouse-Geisser-correction, and Huynh-Feldt-correction) were computed. To examine the effect of both the sample size and the number of measurement occasions, sample sizes of n = 20, 40, 60, 80, and 100 were considered as well as measurement occasions of m = 3, 6, and 9. With respect to rANOVA, the results plead for a use of rANOVA with Huynh-Feldt-correction, especially when the sphericity assumption is violated, the sample size is rather small and the number of measurement occasions is large. For MLM-UN, the results illustrate a massive progressive bias for small sample sizes ( n = 20) and m = 6 or more measurement occasions. This effect could not be found in previous simulation studies with a smaller number of measurement occasions. The proportionality of bias and number of measurement occasions should be considered when MLM-UN is used. The good news is that this proportionality can be compensated by means of large sample sizes. Accordingly, MLM-UN can be recommended even for small sample sizes for about three measurement occasions and for large sample sizes for about nine measurement occasions.
Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul
2018-02-01
To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT < 200 μm; B group, 200 μm ≤ CMT < 300 μm; and C group, CMT > 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.
Spreckelsen, C; Juenger, J
2017-09-26
Adequate estimation and communication of risks is a critical competence of physicians. Due to an evident lack of these competences, effective training addressing risk competence during medical education is needed. Test-enhanced learning has been shown to produce marked effects on achievements. This study aimed to investigate the effect of repeated tests implemented on top of a blended learning program for risk competence. We introduced a blended-learning curriculum for risk estimation and risk communication based on a set of operationalized learning objectives, which was integrated into a mandatory course "Evidence-based Medicine" for third-year students. A randomized controlled trial addressed the effect of repeated testing on achievement as measured by the students' pre- and post-training score (nine multiple-choice items). Basic numeracy and statistical literacy were assessed at baseline. Analysis relied on descriptive statistics (histograms, box plots, scatter plots, and summary of descriptive measures), bootstrapped confidence intervals, analysis of covariance (ANCOVA), and effect sizes (Cohen's d, r) based on adjusted means and standard deviations. All of the 114 students enrolled in the course consented to take part in the study and were assigned to either the intervention or control group (both: n = 57) by balanced randomization. Five participants dropped out due to non-compliance (control: 4, intervention: 1). Both groups profited considerably from the program in general (Cohen's d for overall pre vs. post scores: 2.61). Repeated testing yielded an additional positive effect: while the covariate (baseline score) exhibits no relation to the post-intervention score, F(1, 106) = 2.88, p > .05, there was a significant effect of the intervention (repeated tests scenario) on learning achievement, F(1106) = 12.72, p < .05, d = .94, r = .42 (95% CI: [.26, .57]). However, in the subgroup of participants with a high initial numeracy score no similar effect could be observed. Dedicated training can improve relevant components of risk competence of medical students. An already promising overall effect of the blended learning approach can be improved significantly by implementing a test-enhanced learning design, namely repeated testing. As students with a high initial numeracy score did not profit equally from repeated testing, target-group specific opt-out may be offered.
NASA Technical Reports Server (NTRS)
Kenny, Sean P.; Hou, Gene J. W.
1994-01-01
A method for eigenvalue and eigenvector approximate analysis for the case of repeated eigenvalues with distinct first derivatives is presented. The approximate analysis method developed involves a reparameterization of the multivariable structural eigenvalue problem in terms of a single positive-valued parameter. The resulting equations yield first-order approximations to changes in the eigenvalues and the eigenvectors associated with the repeated eigenvalue problem. This work also presents a numerical technique that facilitates the definition of an eigenvector derivative for the case of repeated eigenvalues with repeated eigenvalue derivatives (of all orders). Examples are given which demonstrate the application of such equations for sensitivity and approximate analysis. Emphasis is placed on the application of sensitivity analysis to large-scale structural and controls-structures optimization problems.
Replications and Extensions in Arousal Assessment for Sex Offenders with Developmental Disabilities
ERIC Educational Resources Information Center
Reyes, Jorge R.; Vollmer, Timothy R.; Hall, Astrid
2011-01-01
Three adult male sex offenders with developmental disabilities participated in phallometric assessments that involved repeated measures of arousal when exposed to various stimuli. Arousal assessment outcomes were similar to those obtained by Reyes et al. (2006). Additional data-analysis methods provided further information about sexual…
Analyzing Randomized Controlled Interventions: Three Notes for Applied Linguists
ERIC Educational Resources Information Center
Vanhove, Jan
2015-01-01
I discuss three common practices that obfuscate or invalidate the statistical analysis of randomized controlled interventions in applied linguistics. These are (a) checking whether randomization produced groups that are balanced on a number of possibly relevant covariates, (b) using repeated measures ANOVA to analyze pretest-posttest designs, and…
Neurobehavioral studies pose unique challenges for dose-response modeling, including small sample size and relatively large intra-subject variation, repeated measurements over time, multiple endpoints with both continuous and ordinal scales, and time dependence of risk characteri...
On Latent Change Model Choice in Longitudinal Studies
ERIC Educational Resources Information Center
Raykov, Tenko; Zajacova, Anna
2012-01-01
An interval estimation procedure for proportion of explained observed variance in latent curve analysis is discussed, which can be used as an aid in the process of choosing between linear and nonlinear models. The method allows obtaining confidence intervals for the R[squared] indexes associated with repeatedly followed measures in longitudinal…
Subtle Cognitive Effects of Moderate Hypoxia
2009-08-01
using SPSS® 13.0 with significance set at an alpha level of .05 for all statistical tests. A repeated measures analysis of variance (ANOVA) was...there was not statistically significant change in reaction time (p=.781), accuracy (p=.152), or throughout (p=.967) with increasing altitude. The...results indicate that healthy individuals aged 19 to 45 years do not experience significant cognitive deficit, as measured by the CogScreen®-HE, when
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.
Plaque formation and removal assessed in vivo in a novel repeated measures imaging methodology.
White, Donald J; Kozak, Kathy M; Baker, Rob; Saletta, Lisa
2006-01-01
A repeated measures digital imaging technique (Digital Plaque Image Analysis) was used to assess variations in plaque formation, including levels of plaque developed following evening and morning tooth brushing with a standard dentifrice, to establish a baseline for future assessments of antimicrobial formulations. Following a rigorous oral hygiene period, subjects were provided with a standard commercial (non-antibacterial) dentifrice and manual toothbrush and instructed to brush b.i.d., as normal. On six separate days over two weeks, subjects reported at three times for a daily plaque assessment: in the morning before oral hygiene, post-brushing, and in the afternoon post-brushing. Morning plaque levels covered approximately 10% of the measured dentition, and plaque was removed by 75% with morning tooth brushing. Plaque underwent rapid regrowth during the day, and averaged approximately 7% coverage by the afternoon. These results support the value of Digital Plaque Image Analysis in recording diurnal plaque variations and treatment effects, and suggest that assessment of oral hygiene efficacy (either mechanical or chemopreventive) accounts for diurnal variations in plaque formation. In addition, the results suggest that plaque regrowth and virulence activity overnight is a significant target for oral hygiene interventions.
Solov'ev, V V; Kel', A E; Kolchanov, N A
1989-01-01
The factors, determining the presence of inverted and symmetrical repeats in genes coding for globular proteins, have been analysed. An interesting property of genetical code has been revealed in the analysis of symmetrical repeats: the pairs of symmetrical codons corresponded to pairs of amino acids with mostly similar physical-chemical parameters. This property may explain the presence of symmetrical repeats and palindromes only in genes coding for beta-structural proteins-polypeptides, where amino acids with similar physical-chemical properties occupy symmetrical positions. A stochastic model of evolution of polynucleotide sequences has been used for analysis of inverted repeats. The modelling demonstrated that only limiting of sequences (uneven frequencies of used codons) is enough for arising of nonrandom inverted repeats in genes.
Antera 3D capabilities for pore measurements.
Messaraa, C; Metois, A; Walsh, M; Flynn, J; Doyle, L; Robertson, N; Mansfield, A; O'Connor, C; Mavon, A
2018-04-29
The cause of enlarged pores remains obscure but still remains of concern for women. To complement subjective methods, bioengineered methods are needed for quantification of pores visibility following treatments. The study objective was to demonstrate the suitability of pore measurements from the Antera 3D. Pore measurements were collected on 22 female volunteers aged 18-65 years with the Antera 3D, the DermaTOP and image analysis on photographs. Additionally, 4 raters graded pore size on photographs on a scale 0-5. Repeatability of Antera 3D parameters was ascertained and the benefit of a pore minimizer product on the cheek was assessed on a sub panel of seven female volunteers. Pore parameters using the Antera were shown to depict pore severity similar to raters on photographs, except for Max Depth. Mean pore volume, mean pore area and count were moderately correlated with DermaTOP parameters (up to r = .50). No relationship was seen between the Antera 3D and pore visibility analysis on photographs. The most repeatable parameters were found to be mean pore volume, mean pore area and max depth, especially for the small and medium filters. The benefits of a pore minimizer product were the most striking for mean pore volume and mean pore area when using the small filter for analysis, rather than the medium/large ones. Pore measurements with the Antera 3D represent a reliable tool for efficacy and field studies, with an emphasis of the small filter for analysis for the mean pore volume/mean pore area parameters. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Habets, Petra; Jeandarme, Inge; Uzieblo, Kasia; Oei, Karel; Bogaerts, Stefan
2015-01-01
Background: A stable assessment of cognition is of paramount importance for forensic psychiatric patients (FPP). The purpose of this study was to compare repeated measures of IQ scores in FPPs with and without intellectual disability. Methods: Repeated measurements of IQ scores in FPPs (n = 176) were collected. Differences between tests were…
Doros, Gheorghe; Pencina, Michael; Rybin, Denis; Meisner, Allison; Fava, Maurizio
2013-07-20
Previous authors have proposed the sequential parallel comparison design (SPCD) to address the issue of high placebo response rate in clinical trials. The original use of SPCD focused on binary outcomes, but recent use has since been extended to continuous outcomes that arise more naturally in many fields, including psychiatry. Analytic methods proposed to date for analysis of SPCD trial continuous data included methods based on seemingly unrelated regression and ordinary least squares. Here, we propose a repeated measures linear model that uses all outcome data collected in the trial and accounts for data that are missing at random. An appropriate contrast formulated after the model has been fit can be used to test the primary hypothesis of no difference in treatment effects between study arms. Our extensive simulations show that when compared with the other methods, our approach preserves the type I error even for small sample sizes and offers adequate power and the smallest mean squared error under a wide variety of assumptions. We recommend consideration of our approach for analysis of data coming from SPCD trials. Copyright © 2013 John Wiley & Sons, Ltd.
Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R
2018-06-01
3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2 ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies, differences ≥ 25% in 18 F-FLT SUV metrics likely represent a true change in tumor uptake. Larger differences are required for FLT metrics comprising volume estimates when no lesion selection criteria are applied.
Micro-XRF : Elemental Analysis for In Situ Geology and Astrobiology Exploration
NASA Technical Reports Server (NTRS)
Allwood, Abigail; Hodyss, Robert; Wade, Lawrence
2012-01-01
The ability to make close-up measurements of rock chemistry is one of the most fundamental tools for astrobiological exploration of Mars and other rocky bodies of the solar system. When conducting surface-based exploration, lithochemical measurements provide critical data that enable interpretation of the local geology, which in turn is vital for determining habitability and searching for evidence of life. The value of lithochemical measurements for geological interpretations has been repeatedly demonstrated with virtually every landed Mars mission over the past four decades.
BODY-ORIENTED THERAPY IN RECOVERY FROM CHILD SEXUAL ABUSE: AN EFFICACY STUDY
Price, Cynthia
2007-01-01
Context There has been little research on body therapy for women in sexual abuse recovery. This study examines body-oriented therapy—an approach focused on body awareness and involving the combination of bodywork and the emotional processing of psychotherapy. Objective To examine the efficacy and the perceived influence on abuse recovery of body-oriented therapy. Massage therapy served as a relative control condition to address the lack of touch-based comparisons in bodywork research. Design A 2-group, repeated measures design was employed, involving randomization to either body-oriented therapy or massage group, conducted in 8, hour-long sessions by 1 of 4 research clinicians. Statistical and qualitative analysis was employed to provide both empirical and experiential perspectives on the study process. Setting Participants were seen in treatment rooms of a university in the northwestern United States and in clinician’s private offices. Participants Twenty-four adult females in psychotherapy for child sexual abuse. Interventions Body-oriented therapy protocol was delivered in three stages, involving massage, body awareness exercises, and inner-body focusing process. Massage therapy protocol was stan- dardized. Both protocols were delivered over clothes. Main Outcome Measures The outcomes reflected 3 key con-structs—psychological well being, physical well-being, and body connection. Repeated measures included: Brief Symptom Inventory, Dissociative Experiences Scale, Crime-Related Post Traumatic Stress Disorder Scale, Medical Symptoms Checklist, Scale of Body Connection and Scale of Body Investment. Results were gathered at 6 time points: baseline, 2 times during intervention, post-intervention, and at 1 month and 3 months follow-up. To examine the experiential perspective of the study process, written questionnaires were administered before and after intervention and at 1 month and 3 months follow-up. Results Repeated measures analysis of variance (ANOVA) indicated significant improvement on all outcome measures for both intervention groups, providing support for the efficacy of body therapy in recovery from childhood sexual abuse. There were no statistically significant differences between groups; however, qualitative analysis of open-ended questions about participant intervention experience revealed that the groups differed on perceived experience of the intervention and its influence on therapeutic recovery. PMID:16189948
Pilotte, Nils; Papaiakovou, Marina; Grant, Jessica R; Bierwert, Lou Ann; Llewellyn, Stacey; McCarthy, James S; Williams, Steven A
2016-03-01
The soil transmitted helminths are a group of parasitic worms responsible for extensive morbidity in many of the world's most economically depressed locations. With growing emphasis on disease mapping and eradication, the availability of accurate and cost-effective diagnostic measures is of paramount importance to global control and elimination efforts. While real-time PCR-based molecular detection assays have shown great promise, to date, these assays have utilized sub-optimal targets. By performing next-generation sequencing-based repeat analyses, we have identified high copy-number, non-coding DNA sequences from a series of soil transmitted pathogens. We have used these repetitive DNA elements as targets in the development of novel, multi-parallel, PCR-based diagnostic assays. Utilizing next-generation sequencing and the Galaxy-based RepeatExplorer web server, we performed repeat DNA analysis on five species of soil transmitted helminths (Necator americanus, Ancylostoma duodenale, Trichuris trichiura, Ascaris lumbricoides, and Strongyloides stercoralis). Employing high copy-number, non-coding repeat DNA sequences as targets, novel real-time PCR assays were designed, and assays were tested against established molecular detection methods. Each assay provided consistent detection of genomic DNA at quantities of 2 fg or less, demonstrated species-specificity, and showed an improved limit of detection over the existing, proven PCR-based assay. The utilization of next-generation sequencing-based repeat DNA analysis methodologies for the identification of molecular diagnostic targets has the ability to improve assay species-specificity and limits of detection. By exploiting such high copy-number repeat sequences, the assays described here will facilitate soil transmitted helminth diagnostic efforts. We recommend similar analyses when designing PCR-based diagnostic tests for the detection of other eukaryotic pathogens.
Moreira, Daniel M; Nickel, J Curtis; Andriole, Gerald L; Castro-Santamaria, Ramiro; Freedland, Stephen J
2015-09-01
To evaluate whether baseline acute and chronic prostate inflammation among men with initial negative biopsy for prostate cancer (PC) is associated with PC volume at the 2-year repeat prostate biopsy in a clinical trial with systematic biopsies. Retrospective analysis of 886 men with negative baseline prostate biopsy and positive 2-year repeat biopsy in the Reduction by Dutasteride of PC Events (REDUCE) study. Acute and chronic inflammation and tumor volume were determined by central pathology. The association of baseline inflammation with 2-year repeat biopsy cancer volume was evaluated with linear and Poisson regressions controlling for demographics and laboratory variables. Chronic, acute inflammation, and both were detected in 531 (60%), 12 (1%), and 84 (9%) baseline biopsies, respectively. Acute and chronic inflammation were significantly associated with each other (P < 0.001). Chronic inflammation was associated with larger prostate (P < 0.001) and lower pre-repeat biopsy PSA (P = 0.01). At 2-year biopsy, baseline chronic inflammation was associated with lower mean tumor volume (2.07 µl vs. 3.15 µl; P = 0.001), number of biopsy cores involved (1.78 vs. 2.19; P < 0.001), percent of cores involved (17.8% vs. 22.8%; P < 0.001), core involvement (0.21 µl vs. 0.31 µl; P < 0.001), and overall percent tumor involvement (1.40% vs. 2.01%; P < 0.001). Results were unchanged in multivariable analysis. Baseline acute inflammation was not associated with any tumor volume measurement. In a cohort of men with 2-year repeat prostate biopsy positive for PC after a negative baseline biopsy, baseline chronic inflammation was associated with lower PC volume. © 2015 Wiley Periodicals, Inc.
Measurement of anterior tibial muscle size using real-time ultrasound imaging.
Martinson, H; Stokes, M J
1991-01-01
Cross-sectional images of the anterior tibial muscle group were obtained using real-time ultrasound scanning in 17 normal women. From photographs taken of the images, the cross-sectional area (CSA) and two linear measurements of muscle cross-section were determined. A measurement of the shortest distance of the muscle depth was termed DS, and a measurement of the longest distance through the muscle group was termed DL. Both linear dimensions showed a positive correlation with CSA and the best correlations were obtained when the dimensions were squared or combined (DS x DL). The correlation values were: CSA vs DS2, r = 0.9; CSA vs DL2, r = 0.75 and CSA vs DS x DL, r = 0.88. An approximate value for CSA could be calculated from DS2 by the equation 2 x DS2 + 1. A shape ratio, obtained by dividing DL by DS, was consistent within the group [mean 2.1 (SD 0.2)] and characterised the muscle geometrically. The CSA of repeated scans was assessed for repeatability between-days and between-scans by analysis of variance and the coefficient of variation (CV) calculated. Areas were repeatable between-days (CV 6.5%) and between-scans (CV 3.6%). Linear dimensions of the anterior tibial muscle group reflected CSA and their potential for assessing changes in muscle size with atrophy and hypertrophy have yet to be established.
A methodological pilot: parenting among women in substance abuse treatment.
Lewin, Linda; Farkas, Kathleen; Niazi, Maryam
2014-01-01
Mothers who abuse substances are likely to have insecure emotional attachment with their children, placing their children at risk for social-emotional and psychiatric conditions. Sobriety does not inevitably improve parenting. We tested recruitment methods, audiovisual (AV) recording procedures, the protocol for identifying child abuse risk, the coding of mother-child interactions, and retention of the sample for repeated measures as the first phase in examining mother-child relational quality of women in substance abuse treatment. This innovative study involved AV recordings to capture the in-vivo mother-child interactional behaviors that were later coded and analyzed for mean scores on the 64-item Parent-Child Relational Quality Assessment. Repeated measurement was planned during treatment and two months after discharge from treatment. The pilot involved a small sample (n = 11) of mother-child (<6 years) dyads. Highest and lowest ratings of interaction behaviors were identified. Mothers showed less enthusiasm and creativity but matched their child's emotional state. The children showed appropriate motor skill items and attachment behaviors. The dyad coding showed less mutual enjoyment between the mother and child. Eight of the participants could not be located for the second measurement despite multiple contact methods. AV recordings capture rich, descriptive information that can be coded for interactional quality analysis. Repeated measurement with this cohort was not feasible, thus needing to assess for additional/more frequent contacts to maintain the sample.
Repeated aeromagnetic surveys in Shinmoe-dake volcano, Japan by using unmanned helicopter
NASA Astrophysics Data System (ADS)
Koyama, T.; Kaneko, T.; Ohminato, T.; Watanabe, A.; Takeo, M.; Yanagisawa, T.; Honda, Y.
2016-12-01
We repeatedly conducted aeromagnetic surveys at Shinmoe-dake volcano, Japan by using unmanned helicopter, and elucidated magnetization structure and its temporal change. At the beginning of 2011, Shinmoe-dake volcano has done magmatic eruptions. After ceasing activities of volcanic eruptions, the first aeromagnetic survey by an unmanned helicopter was performed in the western part of Shinmoe-dake volcano in May 2011. The advantage to use unmanned vehicle for volcanic survey is ability of the safe flight in lower altitude with precise tracks. It enable us forthcoming repeated survey on the same tracks and elucidate the temporal changes of the magnetic fields. The geomagnetic total intensity measurement flight was conducted by installing cesium optical pumping magnetometer on the helicopter, in which the measurement line intervals were almost 100 m and the altitudes were also fixed at almost 100 m above the ground except above the crater. Total measurement length was about 85 km. The data analysis revealed that the averaged magnetization is about 1.5 A/m, typical value of andesite rock, and some horizontal anomalies can be shown.After that, we conducted four repeated surveys so far, and notable temporal changes are detected just around the crater of Shinmoe-dake volcano due to gaining magnetization by cooling of lava which has accumulated in the crater at the 2011 eruptions. The cooling rate just follows square root of elapsed time from the eruptive events, and thus the cooling is being simply done by thermal diffusion. Magnetizing, however, goes on too fast to be done by thermal diffusion only at the surface of lava, and so the cooling may be very effectively done also inside the lava by evaporating water.In this paper, we'll show the detailed results of measurements and discuss the temporal changes of magnetization.
Kim, Mimi; Adams-Campbell, Lucile L; Caan, Bette J; Chlebowski, Rowan T; Neuhouser, Marian L; Shikany, James M; Rohan, Thomas E
2009-01-01
Background: Prospective studies have examined the association of serum and plasma carotenoids and micronutrients and breast cancer; however, to date, studies have only assessed exposure at one point in time. Objective: This study analyzed baseline and repeated serum measurements of carotenoids, retinol, and tocopherols to assess their associations with postmenopausal breast cancer risk. Design: Serum concentrations of α-carotene, β-carotene, β-cryptoxanthin, lycopene, lutein + zeaxanthin, retinol, α-tocopherol, and γ-tocopherol were measured in a 6% sample of women in the Women's Health Initiative clinical trials at baseline and at years 1, 3, and 6 and in a 1% sample of women in the observational study at baseline and at year 3. The association of baseline compounds and breast cancer risk was estimated by Cox proportional hazards models. In addition, repeated measurements were analyzed as time-dependent covariates. Of 5450 women with baseline measurements, 190 incident cases of breast cancer were ascertained over a median of 8.0 y of follow-up. Results: After multivariable adjustment, risk of invasive breast cancer was inversely associated with baseline serum α-carotene concentrations (hazard ratio for highest compared with the lowest tertile: 0.55; 95% CI: 0.34, 0.90; P = 0.02) and positively associated with baseline lycopene (hazard ratio: 1.47; 95% CI: 0.98, 2.22; P = 0.06). Analysis of repeated measurements indicated that α-carotene and β-carotene were inversely associated with breast cancer and that γ-tocopherol was associated with increased risk. Conclusions: The present study, which was the first to assess repeated measurements of serum carotenoids and micronutrients in relation to breast cancer, adds to the evidence of an inverse association of specific carotenoids with breast cancer. The positive associations observed for lycopene and γ-tocopherol require confirmation. This trial was registered at clinicaltrials.gov as NCT00000611. PMID:19474140
Shetty, Rohit; Agrawal, Aarti; Deshmukh, Rashmi; Kaweri, Luci; Rao, Harsha L; Nagaraja, Harsha; Jayadev, Chaitra
2017-01-01
Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL) haze on the measurement and repeatability of pachymetry and mean keratometry (Km) of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL) underwent imaging with a scanning slit imaging device (Orbscan II) and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei). Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT) and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05) significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively). Km values were affected by haze when measured with the Pentacam HR (P < 0.05). The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively), Km values (P = 0.4 and 0.6, respectively), repeatability of TCT (P = 0.1 in both zones), and Km (P = 0.5 and 0.1, respectively) with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution. PMID:28513495
2013-07-01
person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control ...were obtained. Data Analysis Data are expressed as mean T SEM. Between- group anal- ysis (Halo vs. Bolin) was performed using two-way repeated...measures analysis of variance. Bonferroni post test was used to compare replicate means at each PTx level. Within- group (treat- ment) analysis was performed
Isolation of human simple repeat loci by hybridization selection.
Armour, J A; Neumann, R; Gobert, S; Jeffreys, A J
1994-04-01
We have isolated short tandem repeat arrays from the human genome, using a rapid method involving filter hybridization to enrich for tri- or tetranucleotide tandem repeats. About 30% of clones from the enriched library cross-hybridize with probes containing trimeric or tetrameric tandem arrays, facilitating the rapid isolation of large numbers of clones. In an initial analysis of 54 clones, 46 different tandem arrays were identified. Analysis of these tandem repeat loci by PCR showed that 24 were polymorphic in length; substantially higher levels of polymorphism were displayed by the tetrameric repeat loci isolated than by the trimeric repeats. Primary mapping of these loci by linkage analysis showed that they derive from 17 chromosomes, including the X chromosome. We anticipate the use of this strategy for the efficient isolation of tandem repeats from other sources of genomic DNA, including DNA from flow-sorted chromosomes, and from other species.
Psychophysiological correlates of relaxation induced by standard autogenic training.
Mishima, N; Kubota, S; Nagata, S
1999-01-01
The present study aimed to determine the psychophysiological changes induced in subjects by standard autogenic training (AT). Physiological measurements were taken under strict experimental conditions. Thirty-one healthy students were divided randomly into two groups: the AT group and the control group. In the first session, the physiological variables were measured for all students before and after all were asked to relax in their own way. The AT group were then taught AT for 3 months, after which time the measurements were repeated. In the second session, the AT group practised the standard AT exercise, while the control group repeated their own form of simple relaxation. Electrocardiogram, plethysmogram (PTG) and blood pressure (BP) were measured while the students carried out a breathing rate of 15 cycles/min. The R-R intervals and BP were analysed by an autoregressive model for spectral analysis, and the data were compared by repeated-measures ANOVA. The AT group had a significant increase in the mean R-R interval and a significant decrease in the baseline deflection of the PTG in the second session. There were no significant changes in sympathetic activity except for the change in the PTG, although low frequency amplitude of systolic BP decreased slightly. AT was found to induce significant changes that were independent of respiration in healthy students, although paced breathing might have operated as a mental stress. The increase in mean R-R interval and the decrease in baseline deflection of the PTG were the most robust correlates of AT.
Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.
Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm
2006-01-01
To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.
NASA Astrophysics Data System (ADS)
Bugała, Artur; Bednarek, Karol; Kasprzyk, Leszek; Tomczewski, Andrzej
2017-10-01
The paper presents the most representative - from the three-year measurement time period - characteristics of daily and monthly electricity production from a photovoltaic conversion using modules installed in a fixed and 2-axis tracking construction. Results are presented for selected summer, autumn, spring and winter days. Analyzed measuring stand is located on the roof of the Faculty of Electrical Engineering Poznan University of Technology building. The basic parameters of the statistical analysis like mean value, standard deviation, skewness, kurtosis, median, range, or coefficient of variation were used. It was found that the asymmetry factor can be useful in the analysis of the daily electricity production from a photovoltaic conversion. In order to determine the repeatability of monthly electricity production, occurring between the summer, and summer and winter months, a non-parametric Mann-Whitney U test was used as a statistical solution. In order to analyze the repeatability of daily peak hours, describing the largest value of the hourly electricity production, a non-parametric Kruskal-Wallis test was applied as an extension of the Mann-Whitney U test. Based on the analysis of the electric energy distribution from a prepared monitoring system it was found that traditional forecasting methods of the electricity production from a photovoltaic conversion, like multiple regression models, should not be the preferred methods of the analysis.
Application of Six Sigma methodology to a diagnostic imaging process.
Taner, Mehmet Tolga; Sezen, Bulent; Atwat, Kamal M
2012-01-01
This paper aims to apply the Six Sigma methodology to improve workflow by eliminating the causes of failure in the medical imaging department of a private Turkish hospital. Implementation of the design, measure, analyse, improve and control (DMAIC) improvement cycle, workflow chart, fishbone diagrams and Pareto charts were employed, together with rigorous data collection in the department. The identification of root causes of repeat sessions and delays was followed by failure, mode and effect analysis, hazard analysis and decision tree analysis. The most frequent causes of failure were malfunction of the RIS/PACS system and improper positioning of patients. Subsequent to extensive training of professionals, the sigma level was increased from 3.5 to 4.2. The data were collected over only four months. Six Sigma's data measurement and process improvement methodology is the impetus for health care organisations to rethink their workflow and reduce malpractice. It involves measuring, recording and reporting data on a regular basis. This enables the administration to monitor workflow continuously. The improvements in the workflow under study, made by determining the failures and potential risks associated with radiologic care, will have a positive impact on society in terms of patient safety. Having eliminated repeat examinations, the risk of being exposed to more radiation was also minimised. This paper supports the need to apply Six Sigma and present an evaluation of the process in an imaging department.
Dundas, Ingrid; Thorsheim, Torbjørn; Hjeltnes, Aslak; Binder, Per Einar
2016-04-02
Mindfulness based stress reduction (MBSR) for academic evaluation anxiety and self-confidence in 70 help-seeking bachelor's and master's students was examined. A repeated measures analysis of covariance on the 46 students who completed pretreatment and posttreatment measures (median age = 24 years, 83% women) showed that evaluation anxiety and self-confidence improved. A growth curve analysis with all 70 original participants showed reductions in both cognitive and emotional components of evaluation anxiety, and that reduction continued postintervention. Although more research is needed, this study indicates that MBSR may reduce evaluation anxiety.
Dundas, Ingrid; Thorsheim, Torbjørn; Hjeltnes, Aslak; Binder, Per Einar
2016-01-01
ABSTRACT Mindfulness based stress reduction (MBSR) for academic evaluation anxiety and self-confidence in 70 help-seeking bachelor’s and master’s students was examined. A repeated measures analysis of covariance on the 46 students who completed pretreatment and posttreatment measures (median age = 24 years, 83% women) showed that evaluation anxiety and self-confidence improved. A growth curve analysis with all 70 original participants showed reductions in both cognitive and emotional components of evaluation anxiety, and that reduction continued postintervention. Although more research is needed, this study indicates that MBSR may reduce evaluation anxiety. PMID:27227169
NASA Technical Reports Server (NTRS)
Baxa, E. G., Jr.
1974-01-01
A theoretical formulation of differential and composite OMEGA error is presented to establish hypotheses about the functional relationships between various parameters and OMEGA navigational errors. Computer software developed to provide for extensive statistical analysis of the phase data is described. Results from the regression analysis used to conduct parameter sensitivity studies on differential OMEGA error tend to validate the theoretically based hypothesis concerning the relationship between uncorrected differential OMEGA error and receiver separation range and azimuth. Limited results of measurement of receiver repeatability error and line of position measurement error are also presented.
Effects of repeated Valsalva maneuver straining on cardiac and vasoconstrictive baroreflex responses
NASA Technical Reports Server (NTRS)
Convertino, Victor A.; Ratliff, Duane A.; Doerr, Donald F.; Ludwig, David A.; Muniz, Gary W.; Benedetti, Erik; Chavarria, Jose; Koreen, Susan; Nguyen, Claude; Wang, Jeff
2003-01-01
INTRODUCTION: We hypothesized that repeated respiratory straining maneuvers (repeated SM) designed to elevate arterial BPs (arterial baroreceptor loading) would acutely increase baroreflex responses. METHODS: We tested this hypothesis by measuring cardiac baroreflex responses to carotid baroreceptor stimulation (neck pressures), and changes in heart rate and diastolic BP after reductions in BP induced by a 15-s Valsalva maneuver in 10 female and 10 male subjects at 1, 3, 6, and 24 h after performing repeated SM. Baroreflex responses were also measured in each subject at 1, 3, 6, and 24 h at the same time on a separate day without repeated SM (control) in a randomized, counter-balanced cross-over experimental design. RESULTS: There was no statistical difference in carotid-cardiac and peripheral vascular baroreflex responses measured across time following repeated SM compared with the control condition. Integrated cardiac baroreflex response (deltaHR/ deltaSBP) measured during performance of a Valsalva maneuver was increased by approximately 50% to 1.1 +/- 0.2 bpm x mm Hg(-1) at 1 h and 1.0 +/- 0.1 bpm x mm Hg(-1) at 3 h following repeated SM compared with the control condition (0.7 +/- 0.1 bpm x mm Hg(-1) at both 1 and 3 h, respectively). However, integrated cardiac baroreflex response after repeated SM returned to control levels at 6 and 24 h after training. These responses did not differ between men and women. CONCLUSIONS: Our results are consistent with the notion that arterial baroreceptor loading induced by repeated SM increased aortic, but not carotid, cardiac baroreflex responses for as long as 3 h after repeated SM. We conclude that repeated SM increases cardiac baroreflex responsiveness which may provide patients, astronauts, and high-performance aircraft pilots with protection from development of orthostatic hypotension.
Intensive Mindfulness Training and the Reduction of Psychological Distress: A Preliminary Study
ERIC Educational Resources Information Center
Ostafin, Brian D.; Chawla, Neharika; Bowen, Sarah; Dillworth, Tiara M.; Witkiewitz, Katie; Marlatt, G. Alan
2006-01-01
There is increasing evidence for the utility of mindfulness training as a clinical intervention. Most of this research has examined secular-based mindfulness instruction. The current study examined the effects of a 10-day Buddhist mindfulness meditation course on the psychological symptoms of 53 participants. A repeated-measures analysis of…
ERIC Educational Resources Information Center
Williams, Nathaniel J.
2009-01-01
Objective: This article introduces and evaluates children's psychosocial rehabilitation, a home- and community-based treatment for children with serious emotional disturbance. Method: In an open-trial design, the author used repeated-measures analysis of variance and Wilcoxon signed-rank tests to assess pre-post outcome ratings for 218…
Impact of an Adlerian Based Pretrial Diversion Program: Self Concept and Dissociation
ERIC Educational Resources Information Center
Norvell, Jeanell J.
2010-01-01
Clients' self concepts and dissociative experiences were examined to determine the impact of an Adlerian based pretrial diversion program. Clients completing the program displayed a significant change in self concepts and dissociative experiences. A repeated measures multivariate analysis of variance indicated a 35% change, made up of the…
USDA-ARS?s Scientific Manuscript database
Soil moisture is an intrinsic state variable that varies considerably in space and time. Although soil moisture is highly variable, repeated measurements of soil moisture at the field or small watershed scale can often reveal certain locations as being temporally stable and representative of the are...
A Comparison of Vocal Demands with Vocal Performance among Classroom Student Teachers
ERIC Educational Resources Information Center
Franca, Maria Claudia
2013-01-01
Purpose: This investigation compared voice performance of student teachers across an academic semester in order to examine the effect of increasing demands on their voice. Method: A repeated measures design was applied to the data analysis: all participants were tested three separate times throughout the semester. The equipments used for…
A Standardized Mean Difference Effect Size for Multiple Baseline Designs across Individuals
ERIC Educational Resources Information Center
Hedges, Larry V.; Pustejovsky, James E.; Shadish, William R.
2013-01-01
Single-case designs are a class of research methods for evaluating treatment effects by measuring outcomes repeatedly over time while systematically introducing different condition (e.g., treatment and control) to the same individual. The designs are used across fields such as behavior analysis, clinical psychology, special education, and…
Modeling containment of large wildfires using generalized linear mixed-model analysis
Mark Finney; Isaac C. Grenfell; Charles W. McHugh
2009-01-01
Billions of dollars are spent annually in the United States to contain large wildland fires, but the factors contributing to suppression success remain poorly understood. We used a regression model (generalized linear mixed-model) to model containment probability of individual fires, assuming that containment was a repeated-measures problem (fixed effect) and...
Mixture Distribution Latent State-Trait Analysis: Basic Ideas and Applications
ERIC Educational Resources Information Center
Courvoisier, Delphine S.; Eid, Michael; Nussbeck, Fridtjof W.
2007-01-01
Extensions of latent state-trait models for continuous observed variables to mixture latent state-trait models with and without covariates of change are presented that can separate individuals differing in their occasion-specific variability. An empirical application to the repeated measurement of mood states (N = 501) revealed that a model with 2…
Jesus, Gilmar Mercês de; Assis, Maria Alice Altenburg de; Kupek, Emil; Dias, Lizziane Andrade
2017-01-01
The quality control of data entry in computerized questionnaires is an important step in the validation of new instruments. The study assessed the consistency of recorded weight and height on the Food Intake and Physical Activity of School Children (Web-CAAFE) between repeated measures and against directly measured data. Students from the 2nd to the 5th grade (n = 390) had their weight and height directly measured and then filled out the Web-CAAFE. A subsample (n = 92) filled out the Web-CAAFE twice, three hours apart. The analysis included hierarchical linear regression, mixed linear regression model, to evaluate the bias, and intraclass correlation coefficient (ICC), to assess consistency. Univariate linear regression assessed the effect of gender, reading/writing performance, and computer/internet use and possession on residuals of fixed and random effects. The Web-CAAFE showed high values of ICC between repeated measures (body weight = 0.996, height = 0.937, body mass index - BMI = 0.972), and regarding the checked measures (body weight = 0.962, height = 0.882, BMI = 0.828). The difference between means of body weight, height, and BMI directly measured and recorded was 208 g, -2 mm, and 0.238 kg/m², respectively, indicating slight BMI underestimation due to underestimation of weight and overestimation of height. This trend was related to body weight and age. Height and weight data entered in the Web-CAAFE by children were highly correlated with direct measurements and with the repeated entry. The bias found was similar to validation studies of self-reported weight and height in comparison to direct measurements.
Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.
Johnson, Mark I.; Francis, Peter
2018-01-01
Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885
Bathke, Arne C.; Friedrich, Sarah; Pauly, Markus; Konietschke, Frank; Staffen, Wolfgang; Strobl, Nicolas; Höller, Yvonne
2018-01-01
ABSTRACT To date, there is a lack of satisfactory inferential techniques for the analysis of multivariate data in factorial designs, when only minimal assumptions on the data can be made. Presently available methods are limited to very particular study designs or assume either multivariate normality or equal covariance matrices across groups, or they do not allow for an assessment of the interaction effects across within-subjects and between-subjects variables. We propose and methodologically validate a parametric bootstrap approach that does not suffer from any of the above limitations, and thus provides a rather general and comprehensive methodological route to inference for multivariate and repeated measures data. As an example application, we consider data from two different Alzheimer’s disease (AD) examination modalities that may be used for precise and early diagnosis, namely, single-photon emission computed tomography (SPECT) and electroencephalogram (EEG). These data violate the assumptions of classical multivariate methods, and indeed classical methods would not have yielded the same conclusions with regards to some of the factors involved. PMID:29565679
Marine gravimetry using the strapdown gravimeter SGA-WZ
NASA Astrophysics Data System (ADS)
Cai, Shaokun; Tie, Junbo; Zhang, Kaidong; Cao, Juliang; Wu, Meiping
2017-12-01
Gravity can be measured in many ways, from static-point observations to dynamic measurement using land vehicles, ships, aircrafts and satellites. China has developed a gravimetry system based on SINS (Strapdown Inertial Navigation System) named SGA-WZ. This system is the first strapdown gravimetry system in China. Some airborne gravimetry campaigns have been implemented using SGA-WZ. The flight tests indicate that the accuracy of SGA-WZ is 1.5 mGal at a 4.8 km resolution. To test the performance of SGA-WZ when installed on a ship, a marine gravimetry campaign was conducted in the South China Sea in August 2013. In the test, a state-of-the-art commercial sea gravimeter, the LaCoste & Romberg (L&R), was mounted side by side with SGA-WZ. The test contained 30 survey lines in the west-east direction and four groups of repeat lines in four directions; the evaluation of the repeatability was based on repeat lines. The measurement and in-movement alignment algorithm for strapdown gravimeters in the sea are discussed, and the results and analysis of this test are presented. The results from the repeated lines and the comparison with L&R showed that the accuracy of SGA-WZ is at the level of 1 mGal with a resolution between 0.4 and 0.8 km for shipborne gravimetry. These results indicate that the strapdown gravimetry system SGA-WZ can be used in marine gravimetry and the moving base alignment method can improve the computation efficiency greatly when using the strapdown gravimetry system.
Digital photogrammetry for quantitative wear analysis of retrieved TKA components.
Grochowsky, J C; Alaways, L W; Siskey, R; Most, E; Kurtz, S M
2006-11-01
The use of new materials in knee arthroplasty demands a way in which to accurately quantify wear in retrieved components. Methods such as damage scoring, coordinate measurement, and in vivo wear analysis have been used in the past. The limitations in these methods illustrate a need for a different methodology that can accurately quantify wear, which is relatively easy to perform and uses a minimal amount of expensive equipment. Off-the-shelf digital photogrammetry represents a potentially quick and easy alternative to what is readily available. Eighty tibial inserts were visually examined for front and backside wear and digitally photographed in the presence of two calibrated reference fields. All images were segmented (via manual and automated algorithms) using Adobe Photoshop and National Institute of Health ImageJ. Finally, wear was determined using ImageJ and Rhinoceros software. The absolute accuracy of the method and repeatability/reproducibility by different observers were measured in order to determine the uncertainty of wear measurements. To determine if variation in wear measurements was due to implant design, 35 implants of the three most prevalent designs were subjected to retrieval analysis. The overall accuracy of area measurements was 97.8%. The error in automated segmentation was found to be significantly lower than that of manual segmentation. The photogrammetry method was found to be reasonably accurate and repeatable in measuring 2-D areas and applicable to determining wear. There was no significant variation in uncertainty detected among different implant designs. Photogrammetry has a broad range of applicability since it is size- and design-independent. A minimal amount of off-the-shelf equipment is needed for the procedure and no proprietary knowledge of the implant is needed. (c) 2006 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
deVarvalho, Robert; Desai, Shailen D.; Haines, Bruce J.; Kruizinga, Gerhard L.; Gilmer, Christopher
2013-01-01
This software provides storage retrieval and analysis functionality for managing satellite altimetry data. It improves the efficiency and analysis capabilities of existing database software with improved flexibility and documentation. It offers flexibility in the type of data that can be stored. There is efficient retrieval either across the spatial domain or the time domain. Built-in analysis tools are provided for frequently performed altimetry tasks. This software package is used for storing and manipulating satellite measurement data. It was developed with a focus on handling the requirements of repeat-track altimetry missions such as Topex and Jason. It was, however, designed to work with a wide variety of satellite measurement data [e.g., Gravity Recovery And Climate Experiment -- GRACE). The software consists of several command-line tools for importing, retrieving, and analyzing satellite measurement data.
Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.
Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo
2015-01-01
We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.
Giordano, Katie; McGrath, Nuala; Snow, Rachel; Harlow, Siobán; Newell, Marie-Louise
2014-01-01
Background For many estimation purposes, individuals who repeatedly refuse to participate in longitudinal HIV surveillance pose a bigger threat to valid inferences than individuals who participate at least occasionally. We investigate the determinants of repeated refusal to consent to HIV testing in a population-based longitudinal surveillance in rural South Africa. Methods We used data from two years (2005 & 2006) of the annual HIV surveillance conducted by the Africa Centre for Health and Population Studies, linking the HIV surveillance data to demographic and socioeconomic data. The outcome for the analysis was “repeated refusal”. Demographic variables included sex, age, highest educational attainment, and place of residence. We also included a measure of wealth and the variable “ever had sex”. To compare the association of each variable with the outcome, unadjusted odds ratios and standard errors were estimated. Multivariable logistic regression was used to estimate adjusted odds ratios and their standard errors. Data were analyzed using STATA 10.0. Results Of 15,557 eligible individuals, 46% refused to test for HIV in both rounds. Males were significantly more likely than females to repeatedly refuse testing. Holding all other variables constant, individuals in the middle age groups were more likely to repeatedly refuse testing compared with younger and older age groups. The odds of repeated refusal increased with increasing level of education and relative wealth. People living in urban areas were significantly more likely to repeatedly refuse an HIV test than people living in peri-urban or rural areas. Compared to those who had ever had sex, both males and females who had not yet had sex were significantly more likely to refuse to participate. Conclusions The likelihood of repeated refusal to test for HIV in this longitudinal surveillance increases with education, wealth, urbanization, and primary sexual abstinence. Since the factors determining repeated HIV testing refusal are likely associated with HIV status, it is critical that selection effects are controlled for in the analysis of HIV surveillance data. Interventions to increase consent to HIV testing should consider targeting the relatively well educated and wealthy, people in urban areas, and individuals who have not yet sexually debuted. PMID:25621095
Cheung, Gordon; Goonewardene, Mithran Suresh; Islam, Syed Mohammed Shamsul; Murray, Kevin; Koong, Bernard
2013-05-01
To assess the validity of using jugale (J) and Antegonion (Ag) on Posterior-Anterior cephalograms (PAC) as landmarks for transverse intermaxillary analysis when compared with Cone Beam Computed Tomography (CBCT). Conventional PAC and CBCT images were taken of 28 dry skulls. Craniometric measurements between the bilateral landmarks, Antegonion and Jugale, were obtained from the skulls using a microscribe and recorded as the base standard. The corresponding andmarks were identified and measured on CBCT and PAC and compared with the base standard measurements. The accuracy and reliability of the measurements were statistically evaluated and the validity was assessed by comparing the ability of the two image modalities to accurately diagnose an arbitrarily selected J-J/Ag-Ag ratio. All measurements were repeated at least 7 weeks apart. Intra-class correlations (ICC) and Bland-Altman plots were used to analyse the data. All three methods were shown to be reliable as all had a mean error of less than 0.5 mm between repeated measurements. When compared with the base standard, CBCT measurements were shown to have higher agreement (ICC: 0.861-0.964) compared with measurements taken from PAC (ICC: 0.794-0.796). When the arbitrary J-J/Ag-Ag ratio was assessed, 18 per cent of cases were incorrectly diagnosed with a transverse discrepancy on the PAC compared with the CBCT which incorrectly diagnosed 8.7 per cent. CBCT was shown to be more reliable in assessing intermaxillary transverse discrepancy compared with PAC when using J-J/Ag-Ag ratios.
Giannotti, E; Waugh, S; Priba, L; Davis, Z; Crowe, E; Vinnicombe, S
2015-09-01
Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan-scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26-61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29-70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADCS) and the ADC value of a small region of interest (ROI) on the same slice (ADCmin). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Scanner stability contributed 6% error to phantom ADC measurements (0.071×10(-3)mm(2)/s; mean ADC=1.089×10(-3)mm(2)/s). The measured scan-scan CoR in the volunteers was 0.122×10(-3)mm(2)/s, contributing an error of 8% to the mean measured values (ADCscan1=1.529×10(-3)mm(2)/s; ADCscan2=1.507×10(-3)mm(2)/s). Technical and clinical observers demonstrated excellent intra-observer repeatability (ICC>0.9). Clinical observer CoR values were marginally better than technical observer measures (ADCS=0.035×10(-3)mm(2)/s vs. 0.097×10(-3)mm(2)/s; ADCmin=0.09×10(-3)mm(2)/s vs. 0.114×10(-3)mm(2)/s). Inter-reader ICC values were good 0.864 (ADCS) and fair 0.677 (ADCmin). Corresponding CoR values were 0.202×10(-3)mm(2)/s and 0.264×10(-3)mm(2)/s, respectively. Both scanner stability and scan-scan variation have minimal influence on breast ADC measurements, contributing less than 10% error of average measured ADC values. Measurement of ADC values from a small ROI contributes a greater variability in measurements compared with measurement of ADC across the whole visible tumor on one slice. The greatest source of error in follow-up studies is likely to be associated with measures made by multiple observers, and this should be considered where multiple measures are required to assess response to treatment. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Effects of massage on physiological restoration, perceived recovery, and repeated sports performance
Hemmings, B.; Smith, M.; Graydon, J.; Dyson, R.
2000-01-01
Background—Despite massage being widely used by athletes, little scientific evidence exists to confirm the efficacy of massage for promoting both physiological and psychological recovery after exercise and massage effects on performance. Aim—To investigate the effect of massage on perceived recovery and blood lactate removal, and also to examine massage effects on repeated boxing performance. Methods—Eight amateur boxers completed two performances on a boxing ergometer on two occasions in a counterbalanced design. Boxers initially completed performance 1, after which they received a massage or passive rest intervention. Each boxer then gave perceived recovery ratings before completing a second performance, which was a repeated simulation of the first. Heart rates and blood lactate and glucose levels were also assessed before, during, and after all performances. Results—A repeated measures analysis of variance showed no significant group differences for either performance, although a main effect was found showing a decrement in punching force from performance 1 to performance 2 (p<0.05). A Wilcoxon matched pairs test showed that the massage intervention significantly increased perceptions of recovery (p<0.01) compared with the passive rest intervention. A doubly multivariate multiple analysis of variance showed no differences in blood lactate or glucose following massage or passive rest interventions, although the blood lactate concentration after the second performance was significantly higher following massage (p<0.05). Conclusions—These findings provide some support for the psychological benefits of massage, but raise questions about the benefit of massage for physiological restoration and repeated sports performance. Key Words: massage; lactate; psychological recovery; physiological recovery; performance PMID:10786866
ATM kinase is required for telomere elongation in mouse and human cells
Lee, Stella Suyong; Bohrson, Craig; Pike, Alexandra Mims; Wheelan, Sarah Jo; Greider, Carol Widney
2015-01-01
Summary Short telomeres induce a DNA damage response, senescence and apoptosis; thus, maintaining telomere length equilibrium is essential for cell viability. Telomerase addition of telomere repeats is tightly regulated in cells. To probe pathways that regulate telomere addition, we developed the ADDIT assay to measure new telomere addition at a single telomere in vivo. Sequence analysis showed telomerase specific addition of repeats onto a new telomere occurred in just 48 hr. Using the ADDIT assay, we found that ATM is required for addition of new repeats onto telomeres in mouse cells. Evaluation of bulk telomeres, in both human and mouse cells, showed that blocking ATM inhibited telomere elongation. Finally, the activation of ATM through the inhibition of PARP1 resulted in increased telomere elongation, supporting the central role of the ATM pathway in regulating telomere addition. Understanding this role of ATM may yield new areas for possible therapeutic intervention in telomere-mediated disease. PMID:26586427
Video camera system for locating bullet holes in targets at a ballistics tunnel
NASA Technical Reports Server (NTRS)
Burner, A. W.; Rummler, D. R.; Goad, W. K.
1990-01-01
A system consisting of a single charge coupled device (CCD) video camera, computer controlled video digitizer, and software to automate the measurement was developed to measure the location of bullet holes in targets at the International Shooters Development Fund (ISDF)/NASA Ballistics Tunnel. The camera/digitizer system is a crucial component of a highly instrumented indoor 50 meter rifle range which is being constructed to support development of wind resistant, ultra match ammunition. The system was designed to take data rapidly (10 sec between shoots) and automatically with little operator intervention. The system description, measurement concept, and procedure are presented along with laboratory tests of repeatability and bias error. The long term (1 hour) repeatability of the system was found to be 4 microns (one standard deviation) at the target and the bias error was found to be less than 50 microns. An analysis of potential errors and a technique for calibration of the system are presented.
Williams, C; Wilkinson, M; McShane, P; Pennington, D; Fernandez, C; Pierce, S
2011-06-01
Healthcare-associated infection is an important worldwide problem that could be reduced by better hand hygiene practice. However, an increasing number of healthcare workers are experiencing irritant contact dermatitis of the hands as a result of repeated hand washing. This may lead to a reduced level of compliance with regard to hand hygiene. To assess whether a measure of acute irritation by hand soaps could predict the effects of repeated usage over a 2-week period. In a double-blind, randomized comparison study, the comparative irritation potential of four different hand soaps was assessed over a 24-h treatment period. The effect of repeated hand washing with the hand soap products over a 2-week period in healthy adult volunteers on skin barrier function was then determined by assessment of transepidermal water loss (TEWL), epidermal hydration and a visual assessment using the Hand Eczema Severity Index (HECSI) at days 0, 7 and 14. A total of 121 subjects from the 123 recruited completed phase 1 of the study. All four products were seen to be significantly different from each other in terms of the irritant reaction observed and all products resulted in a significantly higher irritation compared with the no-treatment control. Seventy-nine of the initial 121 subjects were then enrolled into the repeated usage study. A statistically significant worsening of the clinical condition of the skin as measured by HECSI was seen from baseline to day 14 in those subjects repeatedly washing their hands with two of the four soap products (products C and D) with P-values of 0·02 and 0·01, respectively. Subclinical assessment of the skin barrier function by measuring epidermal hydration was significantly increased from baseline to day 7 after repeated hand washing with products A, B and D but overall no significant change was seen in all four products tested by day 14. A statistically significant increase in TEWL at day 14 was seen for product A (P = 0·02) indicating a worsening of skin barrier function. This effect was also seen initially for product D at day 7 although this was then lost at day 14. Further regression analysis was then performed to see if the acute irritant test data for each product correlated with the skin barrier data from the repeated usage component of the study. This showed that the results of acute irritant testing of the individual products did not predict the results of chronic use of hand soaps. The results from phase 2 of our study confirm the work of previous studies that show that regular exposure to irritants in daily life leads to stratum corneum damage and impairment of the skin barrier. Although significant differences were seen between the products in phase 1 of the study, regression analysis showed that the results of patch testing of the individual products did not predict the results of chronic use of hand soaps. When designing a study to assess the effects of cumulative use of a product on the skin, the study should mirror the use conditions of the product as closely as possible. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.
Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software
Tello, Emanuel; Rodrigo, Alejandro; Valentinuzzi, Max E.
2018-01-01
Background The rehabilitation process is a fundamental stage for recovery of people's capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient's evolution. This paper proposes a tracking platform of the movement made by an individual's upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. Methods The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient's data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. Results The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists' qualitative assessment shows encouraging results for the clinical use. Conclusion The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert's opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established goniometric methods determines that the proposed software agrees sufficiently to be used interchangeably. PMID:29750166
Tuboimpedance: A New Test of Eustachian Tube Function.
Smith, Matthew E; Zou, Charlie C; Blythe, Andrew J C; Tysome, James R
2017-04-01
Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.
Analysis of Repeatability and Reliability of Warm IRAC Observations of Transiting Exoplanets
NASA Astrophysics Data System (ADS)
Carey, Sean J.; Krick, Jessica; Ingalls, James
2015-12-01
Extracting information about thermal profiles and composition of the atmospheres of transiting exoplanets is extremely challenging due to the small differential signal of the atmosphere in observations of transits, secondary eclipses, and full phase curves for exoplanets. The relevant signals are often at the level of 100 ppm or smaller and require the removal of significant instrumental systematics in the two infrared instruments currently capable of providing information at this precision, WFC3 on HST and IRAC aboard the Spitzer Space Telescope. For IRAC, the systematics are due to the interplay of residual telescope pointing variation with intra-pixel gain variations in the moderately undersampled camera. There is currently a debate in the community on the reliability of repeated IRAC observations of exoplanets particularly those in eclipse from which inferences about atmospheric temperature and pressure profiles can made. To assess the repeatability and reliability of post-cryogenic observations with IRAC, the Spitzer Science Center in conjunction with volunteers from the astronomical community has performed a systematic analysis of the removal of systematics and repeatability of warm IRAC observations. Recently, a data challenge consisting of the measurement of ten secondary eclipses of XO-3b (see Wong et al. 2014) and a complementary analysis of a synthetic version of the XO-3b data was undertaken. We report on the results of this data challenge. Five different techniques were applied to the data (BLISS mapping [Stevenson et al. (2012)], kernel regression using the science data [Wong et al. (2015)] and calibration data [Krick et al. (2015)], pixel-level decorrelation [Deming et al. (2015)], ICA [Morello et al. (2015)] and Gaussian Processes [Evans et al. (2015)]) and found consistent results in terms of eclipse depth and reliability in both the actual and synthetic data. In addition, each technique obtained the input eclipse depth in the simulated data within the stated measurement uncertainty. The reported uncertainties for each measurement approach the photon noise limit. These findings generally refute the results of Hansen et al. (2014) and suggest that inferences about atmospheric properties can be reasonably made using warm IRAC data. Application of our test methods to future observations using JWST (in particular the MIRI instrument) will be discussed.
Mason, H J; Poole, K; Saxton, J
2003-08-01
Accurate diagnosis and staging of hand-arm vibration syndrome (HAVS) is important in health surveillance of vibration-exposed workers and the substantial number of related medico-legal cases. The measurement of the rewarming rate of fingers after cold provocation to the hands (CPT) has been suggested as a useful test in diagnosing HAVS. To investigate the diagnostic value of a standardized version of the CPT test using a 15 degrees C cold challenge for 5 min applied in the recent compensation assessment of UK miners. Analysis of a subset of UK miners assessed at our unit, together with data from a small repeatability study of the standardized CPT in normal subjects. Rewarming time in the CPT was significantly lower in those subjects classified as vascular Stockholm stage 0 compared with Stockholm stages 1-3 combined, but did not discriminate between the stages of abnormality. Using the suggested cut-off in the CPT test, the sensitivity and specificity were calculated as 43 and 78%, respectively. Receiver operator characteristic analysis suggested that the rewarming time of highest accuracy gave a sensitivity of 66% and specificity of 59%. In 10 miners who reported unilateral hand blanching, there was no significant difference in CPT measurements between blanching and non-blanching hands. Repeat CPT measurements in normal subjects suggested mean differences of 52 and 107 s for each hand, and the Bland-Altman coefficient of repeatability was approximately 600 s for all fingers. Single application of this standardized CPT test may have limited value in diagnosing the vascular component of HAVS in an individual.
Zha, Wei; Kruger, Stanley J; Johnson, Kevin M; Cadman, Robert V; Bell, Laura C; Liu, Fang; Hahn, Andrew D; Evans, Michael D; Nagle, Scott K; Fain, Sean B
2018-05-01
A previous study demonstrated the feasibility of using 3D radial ultrashort echo time (UTE) oxygen-enhanced MRI (UTE OE-MRI) for functional imaging of healthy human lungs. The repeatability of quantitative measures from UTE OE-MRI needs to be established prior to its application in clinical research. To evaluate repeatability of obstructive patterns in asthma and cystic fibrosis (CF) with UTE OE-MRI with isotropic spatial resolution and full chest coverage. Volunteer and patient repeatability. Eighteen human subjects (five asthma, six CF, and seven normal subjects). Respiratory-gated free-breathing 3D radial UTE (80 μs) sequence at 1.5T. Two 3D radial UTE volumes were acquired sequentially under normoxic and hyperoxic conditions. A subset of subjects underwent repeat acquisitions on either the same day or ≤15 days apart. Asthma and CF subjects also underwent spirometry. A workflow including deformable registration and retrospective lung density correction was used to compute 3D isotropic percent signal enhancement (PSE) maps. Median PSE (MPSE) and ventilation defect percent (VDP) of the lung were measured from the PSE map. The relations between MPSE, VDP, and spirometric measures were assessed using Spearman correlations. The test-retest repeatability was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICC). Ventilation measures in normal subjects (MPSE = 8.0%, VDP = 3.3%) were significantly different from those in asthma (MPSE = 6.0%, P = 0.042; VDP = 21.7%, P = 0.018) and CF group (MPSE = 4.5%, P = 0.0006; VDP = 27.2%, P = 0.002). MPSE correlated significantly with forced expiratory lung volume in 1 second percent predicted (ρ = 0.72, P = 0.017). The ICC of the test-retest VDP and MPSE were both ≥0.90. In all subject groups, an anterior/posterior gradient was observed with higher MPSE and lower VDP in the posterior compared to anterior regions (P ≤ 0.0021 for all comparisons). 3D radial UTE OE-MRI supports quantitative differentiation of diseased vs. healthy lungs using either whole lung VDP or MPSE with excellent test-retest repeatability. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1287-1297. © 2017 International Society for Magnetic Resonance in Medicine.
Repeat sample intraocular pressure variance in induced and naturally ocular hypertensive monkeys.
Dawson, William W; Dawson, Judyth C; Hope, George M; Brooks, Dennis E; Percicot, Christine L
2005-12-01
To compare repeat-sample means variance of laser induced ocular hypertension (OH) in rhesus monkeys with the repeat-sample mean variance of natural OH in age-range matched monkeys of similar and dissimilar pedigrees. Multiple monocular, retrospective, intraocular pressure (IOP) measures were recorded repeatedly during a short sampling interval (SSI, 1-5 months) and a long sampling interval (LSI, 6-36 months). There were 5-13 eyes in each SSI and LSI subgroup. Each interval contained subgroups from the Florida with natural hypertension (NHT), induced hypertension (IHT1) Florida monkeys, unrelated (Strasbourg, France) induced hypertensives (IHT2), and Florida age-range matched controls (C). Repeat-sample individual variance means and related IOPs were analyzed by a parametric analysis of variance (ANOV) and results compared to non-parametric Kruskal-Wallis ANOV. As designed, all group intraocular pressure distributions were significantly different (P < or = 0.009) except for the two (Florida/Strasbourg) induced OH groups. A parametric 2 x 4 design ANOV for mean variance showed large significant effects due to treatment group and sampling interval. Similar results were produced by the nonparametric ANOV. Induced OH sample variance (LSI) was 43x the natural OH sample variance-mean. The same relationship for the SSI was 12x. Laser induced ocular hypertension in rhesus monkeys produces large IOP repeat-sample variance mean results compared to controls and natural OH.
Fazio, Massimo A; Bruno, Luigi; Reynaud, Juan F; Poggialini, Andrea; Downs, J Crawford
2012-03-01
We proposed and validated a compensation method that accounts for the optical distortion inherent in measuring displacements on specimens immersed in aqueous solution. A spherically-shaped rubber specimen was mounted and pressurized on a custom apparatus, with the resulting surface displacements recorded using electronic speckle pattern interferometry (ESPI). Point-to-point light direction computation is achieved by a ray-tracing strategy coupled with customized B-spline-based analytical representation of the specimen shape. The compensation method reduced the mean magnitude of the displacement error induced by the optical distortion from 35% to 3%, and ESPI displacement measurement repeatability showed a mean variance of 16 nm at the 95% confidence level for immersed specimens. The ESPI interferometer and numerical data analysis procedure presented herein provide reliable, accurate, and repeatable measurement of sub-micrometer deformations obtained from pressurization tests of spherically-shaped specimens immersed in aqueous salt solution. This method can be used to quantify small deformations in biological tissue samples under load, while maintaining the hydration necessary to ensure accurate material property assessment.
McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R
To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations. Copyright © 2017 Elsevier Inc. All rights reserved.
A novel tensile test method to assess texture and gaping in salmon fillets.
Ashton, Thomas J; Michie, Ian; Johnston, Ian A
2010-05-01
A new tensile strength method was developed to quantify the force required to tear a standardized block of Atlantic salmon muscle with the aim of identifying those samples more prone to factory downgrading as a result of softness and fillet gaping. The new method effectively overcomes problems of sample attachment encountered with previous tensile strength tests. The repeatability and sensitivity and predictability of the new technique were evaluated against other common instrumental texture measurement methods. The relationship between sensory assessments of firmness and parameters from the instrumental texture methods was also determined. Data from the new method were shown to have the strongest correlations with gaping severity (r =-0.514, P < 0.001) and the highest level of repeatability of data when analyzing cold-smoked samples. The Warner Bratzler shear method gave the most repeatable data from fresh samples and had the highest correlations between fresh and smoked product from the same fish (r = 0.811, P < 0.001). A hierarchical cluster analysis placed the tensile test in the top cluster, alongside the Warner Bratzler method, demonstrating that it also yields adequate data with respect to these tests. None of the tested sensory analysis attributes showed significant relationships to mechanical tests except fillet firmness, with correlations (r) of 0.42 for cylinder probe maximum force (P = 0.005) and 0.31 for tensile work (P = 0.04). It was concluded that the tensile test method developed provides an important addition to the available tools for mechanical analysis of salmon quality, particularly with respect to the prediction of gaping during factory processing, which is a serious commercial problem. A novel, reliable method of measuring flesh tensile strength in salmon, provides data of relevance to gaping.
2009-08-17
Weight: Repeated Measures (Between-Subjects Effects ) Body Weight: Analysis of Variance (ANOVA) - Males Only Body Weight: Last Measurement Corticosterone ...also decreased the effects of stress on freezing behavior and corticosterone levels in mice (Benaroya-Milshtein et aI., 2004). Summary of Social...rats (e.g., Faradayet aI., 2005; Kalinichev et aI., 2002; Kant et aI., 1987; Hayley et aI., 2001). 22 Corticosterone responses to stressors are
Reliability and Accuracy of Static Parameters Obtained From Ink and Pressure Platform Footprints.
Zuil-Escobar, Juan Carlos; Martínez-Cepa, Carmen Belén; Martín-Urrialde, Jose Antonio; Gómez-Conesa, Antonia
2016-09-01
The purpose of this study was to evaluate the accuracy and the intrarater reliability of arch angle (AA), Staheli Index (SI), and Chippaux-Smirak Index (CSI) obtained from ink and pressure platform footprints. We obtained AA, SI, and CSI measurements from ink pedigraph footprints and pressure platform footprints in 40 healthy participants (aged 25.65 ± 5.187 years). Intrarater reliability was calculated for all parameters obtained using the 2 methods. Standard error of measurement and minimal detectable change were also calculated. A repeated-measure analysis of variance was used to identify differences between ink and pressure platform footprints. Intraclass correlation coefficient and Bland and Altman plots were used to assess similar parameters obtained using different methods. Intrarater reliability was >0.9 for all parameters and was slightly higher for the ink footprints. No statistical difference was reported in repeated-measure analysis of variance for any of the parameters. Intraclass correlation coefficient values from AA, SI, and CSI that were obtained using ink footprints and pressure platform footprints were excellent, ranging from 0.797 to 0.829. However, pressure platform overestimated AA and underestimated SI and CSI. Our study revealed that AA, SI, and CSI were similar regardless of whether the ink or pressure platform method was used. In addition, the parameters indicated high intrarater reliability and were reproducible. Copyright © 2016. Published by Elsevier Inc.
Gregory B. Lawrence; Ivan J. Fernandez; Daniel D. Richter; Donald S. Ross; Paul W. Hazlett; Scott W. Bailey; Rock Ouimet; Richard A. F. Warby; Arthur H. Johnson; Henry Lin; James M. Kaste; Andrew G. Lapenis; Timothy J. Sullivan
2013-01-01
Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest...
Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins
da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho
2011-01-01
Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997
de Oliveira, Anapolino Macedo; Fonseca, Antônio Augusto; Camargos, Marcelo Fernandes; Orzil, Lívia Maria; Laguardia-Nascimento, Mateus; Oliveira, Anna Gabriella Guimarães; Rodrigues, Jacqueline Gomes; Sales, Mariana Lázaro; de Oliveira, Tatiana Flávia Pinheiro; de Melo, Cristiano Barros
2018-07-01
Vesicular stomatitis is an infectious disease that occurs mainly in countries of the Western Hemisphere and affects cattle, swine and horses. The clinical symptoms in cattle and swine are similar to foot-and-mouth disease and include vesicular ulceration of the tongue and mouth. The disease requires a rapid and accurate differential diagnosis, aiming for immediate implementation of control measures. The objective of the present study was to develop and perform validation tests of multiplex RT-qPCR(s) for the detection of RNA from Alagoas vesiculovirus, considering the parameters of sensitivity and analytical specificity, analytical performance (repeatability and reproducibility criteria) and the uncertainty of the measurement. The threshold cycle values obtained in triplicate from each sample were evaluated by considering the variations between days, analysts and equipment in an analysis of variance aimed at determining the variances of repeatability and reproducibility. The results showed that RT-qPCRs had excellent sensitivity and specificity in the detection of RNA of the Alagoas vesiculovirus. The validation parameters showed low coefficients of variation and were equivalent to those found in other validation studies, indicating that the tests presented excellent repeatability and reproducibility. Copyright © 2018 Elsevier B.V. All rights reserved.
Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes
ERIC Educational Resources Information Center
Zavorsky, Gerald S.
2010-01-01
Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…
Ferguson, Kelly K; Chen, Yin-Hsiu; VanderWeele, Tyler J; McElrath, Thomas F; Meeker, John D; Mukherjee, Bhramar
2017-03-01
Mediation analysis is useful for understanding mechanisms and has been used minimally in the study of the environment and disease. We examined mediation of the association between phthalate exposure during pregnancy and preterm birth by oxidative stress. This nested case-control study of preterm birth ( n = 130 cases, 352 controls) included women who delivered in Boston, Massachusestts, from 2006 through 2008. Phthalate metabolites and 8-isoprostane, an oxidative stress biomarker, were measured in urine from three visits in pregnancy. We applied four counterfactual mediation methods: method 1, utilizing exposure and mediator averages; method 2, using averages but allowing for an exposure-mediator interaction; method 3, incorporating longitudinal measurements of the exposure and mediator; and method 4, using longitudinal measurements and allowing for an exposure-mediator interaction. We observed mediation of the associations between phthalate metabolites and all preterm birth by 8-isoprostane, with the greatest estimated proportion mediated observed for spontaneous preterm births specifically. Fully utilizing repeated measures of the exposure and mediator improved precision of indirect (i.e., mediated) effect estimates, and including an exposure-mediator interaction increased the estimated proportion mediated. For example, for mono(2-ethyl-carboxy-propyl) phthalate (MECPP), a metabolite of di(2-ethylhexyl) phthalate (DEHP), the percent of the total effect mediated by 8-isoprostane increased from 47% to 60% with inclusion of an exposure-mediator interaction term, in reference to a total adjusted odds ratio of 1.67 or 1.48, respectively. This demonstrates mediation of the phthalate-preterm birth relationship by oxidative stress, and the utility of complex regression models in capturing mediated associations when repeated measures of exposure and mediator are available and an exposure-mediator interaction may exist. Citation: Ferguson KK, Chen YH, VanderWeele TJ, McElrath TF, Meeker JD, Mukherjee B. 2017. Mediation of the relationship between maternal phthalate exposure and preterm birth by oxidative stress with repeated measurements across pregnancy. Environ Health Perspect 125:488-494; http://dx.doi.org/10.1289/EHP282.
[Polymorphic loci and polymorphism analysis of short tandem repeats within XNP gene].
Liu, Qi-Ji; Gong, Yao-Qin; Guo, Chen-Hong; Chen, Bing-Xi; Li, Jiang-Xia; Guo, Yi-Shou
2002-01-01
To select polymorphic short tandem repeat markers within X-linked nuclear protein (XNP) gene, genomic clones which contain XNP gene were recognized by homologous analysis with XNP cDNA. By comparing the cDNA with genomic DNA, non-exonic sequences were identified, and short tandem repeats were selected from non-exonic sequences by using BCM search Launcher. Polymorphisms of the short tandem repeats in Chinese population were evaluated by PCR amplification and PAGE. Five short tandem repeats were identified from XNP gene, two of which were polymorphic. Four and 11 alleles were observed in Chinese population for XNPSTR1 and XNPSTR4, respectively. Heterozygosities were 47% for XNPSTR1 and 70% for XNPSTR4. XNPSTR1 and XNPSTR4 localized within 3' end and intron 10, respectively. Two polymorphic short tandem repeats have been identified within XNP gene and will be useful for linkage analysis and gene diagnosis of XNP gene.
Lack of maintenance of gait pattern as measured by instrumental methods suggests psychogenic gait.
Merello, Marcelo; Ballesteros, Diego; Rossi, Malco; Arena, Julieta; Crespo, Marcos; Cervio, Andres; Cuello Oderiz, Carolina; Rivero, Alberto; Cerquetti, Daniel; Risk, Marcelo; Balej, Jorge
2012-01-01
Fluctuation is a common feature of all psychogenic gait disorder (PGD) patterns. Whether this fluctuation involves only the degree of impairment or whether it affects the gait pattern itself remains an interesting question. We hypothesize that, on repeated measurements, both normal and abnormal gait may present quantitative differences while maintaining their basic underlying pattern; conversely, in psychogenic gait, the basic pattern appears not to be preserved. Using an optoelectronic system, data acquired from 19 normal subjects and 66 patients were applied to train a neural network (NN) and subsequently classify gait patterns into four different groups (normal, ataxic, spastic-paraparetic and parkinsonian). Five patients who fulfilled clinical criteria for psychogenic gait and six controls were then prospectively evaluated on two separate occasions, three months apart. Normal controls and ataxic, parkinsonian or spastic patients were correctly identified by the NN, and categorized within the corresponding groups at baseline as well as at a three-month follow-up evaluation. NN analysis showed that after three months, no PGD patient preserved the gait pattern detected at baseline, even though this finding was not clinically apparent. Modification of gait pattern detected by repeated kinematic measurement and NN analysis could suggest the presence of PGD, particularly in difficult-to-diagnose cases.
SEM-based overlay measurement between via patterns and buried M1 patterns using high-voltage SEM
NASA Astrophysics Data System (ADS)
Hasumi, Kazuhisa; Inoue, Osamu; Okagawa, Yutaka; Shao, Chuanyu; Leray, Philippe; Halder, Sandip; Lorusso, Gian; Jehoul, Christiane
2017-03-01
The miniaturization of semiconductors continues, importance of overlay measurement is increasing. We measured overlay with analysis SEM called Miracle Eye which can output ultrahigh acceleration voltage in 1998. Meanwhile, since 2006, we have been working on SEM based overlay measurement and developed overlay measurement function of the same layer using CD-SEM. Then, we evaluated overlay of the same layer pattern after etching. This time, in order to measure overlay after lithography, we evaluated the see-through overlay using high voltage SEM CV5000 released in October 2016. In collaboration between imec and Hitachi High-Technologies, we evaluated repeatability, TIS of SEM-OVL as well as correlation between SEM-OVL and Opt-OVL in the M1@ADI and V0@ADI process. Repeatability and TIS results are reasonable and SEM-OVL has good correlation with Opt-OVL. By overlay measurement using CV 5000, we got the following conclusions. (1)SEM_OVL results of both M1 and V0 at ADI show good correlation to OPT_OVL. (2)High voltage SEM can prove the measurement capability of a small pattern(Less than 1 2um) like device that can be placed in-die area. (3)"In-die SEM based overlay" shows possibility for high order control of scanner
2011-05-23
determine if the group means are significantly different. Analysis should include comparison of pretest - posttest means within- group and between... groups . A repeated measures analysis should also be conducted on subject‘s pretest - posttest means within groups . Information gained from the statistical...Black Single Unemployed 30 - 39 Senior NCO Hispanic ≥ 40 Officers Other - A research design embedding a pretest / posttest with a stratified then
Molecular characterization and distribution of a 145-bp tandem repeat family in the genus Populus.
Rajagopal, J; Das, S; Khurana, D K; Srivastava, P S; Lakshmikumaran, M
1999-10-01
This report aims to describe the identification and molecular characterization of a 145-bp tandem repeat family that accounts for nearly 1.5% of the Populus genome. Three members of this repeat family were cloned and sequenced from Populus deltoides and P. ciliata. The dimers of the repeat were sequenced in order to confirm the head-to-tail organization of the repeat. Hybridization-based analysis using the 145-bp tandem repeat as a probe on genomic DNA gave rise to ladder patterns which were identified to be a result of methylation and (or) sequence heterogeneity. Analysis of the methylation pattern of the repeat family using methylation-sensitive isoschizomers revealed variable methylation of the C residues and lack of methylation of the A residues. Sequence comparisons between the monomers revealed a high degree of sequence divergence that ranged between 6% and 11% in P. deltoides and between 4.2% and 8.3% in P. ciliata. This indicated the presence of sub-families within the 145-bp tandem family of repeats. Divergence was mainly due to the accumulation of point mutations and was concentrated in the central region of the repeat. The 145-bp tandem repeat family did not show significant homology to known tandem repeats from plants. A short stretch of 36 bp was found to show homology of 66.7% to a centromeric repeat from Chironomus plumosus. Dot-blot analysis and Southern hybridization data revealed the presence of the repeat family in 13 of the 14 Populus species examined. The absence of the 145-bp repeat from P. euphratica suggested that this species is relatively distant from other members of the genus, which correlates with taxonomic classifications. The widespread occurrence of the tandem family in the genus indicated that this family may be of ancient origin.
Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.
Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S
2014-06-01
A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.
ERIC Educational Resources Information Center
Schweizer, Karl
2008-01-01
Structural equation modeling provides the framework for investigating experimental effects on the basis of variances and covariances in repeated measurements. A special type of confirmatory factor analysis as part of this framework enables the appropriate representation of the experimental effect and the separation of experimental and…
Twenty five years long survival analysis of an individual shortleaf pine trees
Pradip Saud; Thomas B. Lynch; James M. Guldin
2016-01-01
A semi parametric cox proportion hazard model is preferred when censored data and survival time information is available (Kleinbaum and Klein 1996; Alison 2010). Censored data are observations that have incomplete information related to survival time or event time of interest. In repeated forest measurements, usually observations are either right censored or...
ERIC Educational Resources Information Center
Maddox, George L.; Douglass, Elizabeth B.
This paper explores the relationship between age and individual differences. Two hypotheses were tested through the use of repeated measures of functioning in terms of social, psychological, and physiological parameters: (1) individual differences do not decrease with age, and (2) individuals tend to maintain the same rank in relation to age peers…
Mixed Effects Modeling of Morris Water Maze Data: Advantages and Cautionary Notes
ERIC Educational Resources Information Center
Young, Michael E.; Clark, M. H.; Goffus, Andrea; Hoane, Michael R.
2009-01-01
Morris water maze data are most commonly analyzed using repeated measures analysis of variance in which daily test sessions are analyzed as an unordered categorical variable. This approach, however, may lack power, relies heavily on post hoc tests of daily performance that can complicate interpretation, and does not target the nonlinear trends…
The Relationship between Childhood Sexual Abuse and Sexual Health Practices of Homeless Adolescents
ERIC Educational Resources Information Center
Johnson, Regina Jones; Rew, Lynn; Sternglanz, R. Weylin
2006-01-01
This study explored the gender differences in sexual self-concept, personal resources for sexual health, safe sex behaviors, and risky sexual behaviors among homeless adolescents with and without histories of sexual abuse. Data for this secondary analysis were collected in 2003 to 2004 in the first phase of a larger repeated-measures sexual health…
ERIC Educational Resources Information Center
Clarke, Karen; Lane, Andrew M.
2005-01-01
This study investigated the effectiveness of providing tutorial support for education students in core modules. An intervention designed to promote critical thinking skills was developed and delivered in week 11 of a 15 week module. Repeated measures analysis of variance indicated that the improvement in grades in Level 2 was significantly better…
USDA-ARS?s Scientific Manuscript database
The mixed linear model (MLM) is currently among the most advanced and flexible statistical modeling techniques and its use in tackling problems in plant pathology has begun surfacing in the literature. The longitudinal MLM is a multivariate extension that handles repeatedly measured data, such as r...
Chapter 15: Monitoring the effects of fire on nonnative invasive plant species
Steve Sutherland
2008-01-01
Monitoring, as defined by Elzinga and others (1998), is "the collection and analysis of repeated observations or measurements to evaluate changes in condition and progress towards meeting a management objective." Analyses of monitoring data may indicate that a project is meeting land management goals, or it may indicate that goals are not being met and...
One-Session Exposure Treatment for Social Anxiety with Specific Fear of Public Speaking
ERIC Educational Resources Information Center
Hindo, Cindy S.; Gonzalez-Prendes, A. Antonio
2011-01-01
Objectives: This pilot study evaluated the effectiveness of one-session, exposure-based therapy, to treat social anxiety disorder (SAD) with specific fear of public speaking. Methods: A quasi-experimental pre-posttest design with repeated measures-within-subject Analysis of Variance and paired sample t-tests was used to compare pretest, posttest…
An Evaluation of Second Step: What Are the Benefits for Youth With and Without Disabilities?
ERIC Educational Resources Information Center
Sullivan, Terri N.; Sutherland, Kevin S.; Farrell, Albert D.; Taylor, Katherine A.
2015-01-01
The impact of a school-based violence prevention program, Second Step, on peer victimization and aggression, and emotion regulation was evaluated among 457 sixth graders. A cluster-randomized trial was conducted with classrooms randomly assigned to intervention (n = 14) or control (n = 14) conditions. A repeated measures analysis of covariance on…
Lu, Xi; Nahum-Shani, Inbal; Kasari, Connie; Lynch, Kevin G.; Oslin, David W.; Pelham, William E.; Fabiano, Gregory; Almirall, Daniel
2016-01-01
A dynamic treatment regime (DTR) is a sequence of decision rules, each of which recommends a treatment based on a patient’s past and current health status. Sequential, multiple assignment, randomized trials (SMARTs) are multi-stage trial designs that yield data specifically for building effective DTRs. Modeling the marginal mean trajectories of a repeated-measures outcome arising from a SMART presents challenges, because traditional longitudinal models used for randomized clinical trials do not take into account the unique design features of SMART. We discuss modeling considerations for various forms of SMART designs, emphasizing the importance of considering the timing of repeated measures in relation to the treatment stages in a SMART. For illustration, we use data from three SMART case studies with increasing level of complexity, in autism, child attention deficit hyperactivity disorder (ADHD), and adult alcoholism. In all three SMARTs we illustrate how to accommodate the design features along with the timing of the repeated measures when comparing DTRs based on mean trajectories of the repeated-measures outcome. PMID:26638988
Lu, Xi; Nahum-Shani, Inbal; Kasari, Connie; Lynch, Kevin G; Oslin, David W; Pelham, William E; Fabiano, Gregory; Almirall, Daniel
2016-05-10
A dynamic treatment regime (DTR) is a sequence of decision rules, each of which recommends a treatment based on a patient's past and current health status. Sequential, multiple assignment, randomized trials (SMARTs) are multi-stage trial designs that yield data specifically for building effective DTRs. Modeling the marginal mean trajectories of a repeated-measures outcome arising from a SMART presents challenges, because traditional longitudinal models used for randomized clinical trials do not take into account the unique design features of SMART. We discuss modeling considerations for various forms of SMART designs, emphasizing the importance of considering the timing of repeated measures in relation to the treatment stages in a SMART. For illustration, we use data from three SMART case studies with increasing level of complexity, in autism, child attention deficit hyperactivity disorder, and adult alcoholism. In all three SMARTs, we illustrate how to accommodate the design features along with the timing of the repeated measures when comparing DTRs based on mean trajectories of the repeated-measures outcome. Copyright © 2015 John Wiley & Sons, Ltd.
Effects of Expressive Writing Effects on Disgust and Anxiety in a Subsequent Dissection
NASA Astrophysics Data System (ADS)
Randler, Christoph; Wüst-Ackermann, Peter; im Kampe, Viola Otte; Meyer-Ahrens, Inga H.; Tempel, Benjamin J.; Vollmer, Christian
2015-10-01
Emotions influence motivation and achievement, but negative emotions have rarely been assessed in science education. In this study, we assessed the influence of two different expressive writing assignments on disgust and anxiety in university students prior to the dissection of a trout. We randomly assigned students to one of two expressive writing tasks and measured specific state disgust and state anxiety after writing and after the dissection. Specific state disgust was measured a third time after 3 weeks. One writing task was concerned with the dissection, and the other was related to behavioral experiments with mice. We used two general linear models with repeated measures. In the first model, specific state disgust (pre, post, and follow-up) was used as the dependent repeated measure and experimental group as the independent variable. In the second model, state anxiety was used as the dependent repeated measure (pre, post) with experimental group as the independent variable. The repeated testing showed a highly significant effect of experimental group on the repeated measures of disgust. Writing about worries and emotions concerning the dissection leads to higher disgust scores compared to writing about mice. These higher scores persisted even 3 weeks later in the follow-up test. Concerning anxiety, there was a clear influence of the repeated measure of state anxiety, but anxiety was not influenced by the experimental group. We suggest that positive writing should be used in educational contexts to reduce disgust.
Analysis strategies for longitudinal attachment loss data.
Beck, J D; Elter, J R
2000-02-01
The purpose of this invited review is to describe and discuss methods currently in use to quantify the progression of attachment loss in epidemiological studies of periodontal disease, and to make recommendations for specific analytic methods based upon the particular design of the study and structure of the data. The review concentrates on the definition of incident attachment loss (ALOSS) and its component parts; measurement issues including thresholds and regression to the mean; methods of accounting for longitudinal change, including changes in means, changes in proportions of affected sites, incidence density, the effect of tooth loss and reversals, and repeated events; statistical models of longitudinal change, including the incorporation of the time element, use of linear, logistic or Poisson regression or survival analysis, and statistical tests; site vs person level of analysis, including statistical adjustment for correlated data; the strengths and limitations of ALOSS data. Examples from the Piedmont 65+ Dental Study are used to illustrate specific concepts. We conclude that incidence density is the preferred methodology to use for periodontal studies with more than one period of follow-up and that the use of studies not employing methods for dealing with complex samples, correlated data, and repeated measures does not take advantage of our current understanding of the site- and person-level variables important in periodontal disease and may generate biased results.
Piñero, David P; Plaza, Ana Belén; Alió, Jorge L
2008-01-01
To determine the interchangeability of 2 anterior segment imaging systems: a very-high-frequency (VHF) ultrasound scanning system (Artemis 2, Ultralink LLC) and an optical coherence tomography (OCT) system (Visante, Zeiss). Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. This study comprised 20 eyes without pathology or previous surgery. The anterior chamber depth (ACD), central corneal thickness (CCT), angle-to-angle distance (ATA), and the iridocorneal angle size (IAS) at the 0-degree and 180-degree positions were measured with 2 imaging techniques: VHF ultrasound scanning and OCT. Analysis of agreement and interchangeability was performed by the Bland and Altman method. In addition, each measurement was performed 3 times consecutively to determine intrasession repeatability by means of the coefficient of variation (CV) and the intraclass correlation coefficient (ICC). No statistically significant differences were found between imaging techniques in ACD, CCT, or ATA (P>.40). The ranges of agreement were 0.20 mm, 16.11 mum, and 0.80 mm for ACD, CCT, and ATA, respectively. Regarding IAS, no statistically significant differences were found in the nasal (P = .78) or temporal (P = .63) measurements between devices. However, the range of agreement for nasal (14.3 degrees) and temporal (14.90 degrees) values was relevant, indicating the 2 techniques cannot be used interchangeably for IAS measurement. Excellent intrasession repeatability scores were obtained (CV and ICC). The Artemis 2 and the Visante OCT systems provide equivalent and repeatable measurements of the ACD, CCT, and ATA and can be used interchangeably for these purposes.
Algorithm to find distant repeats in a single protein sequence
Banerjee, Nirjhar; Sarani, Rangarajan; Ranjani, Chellamuthu Vasuki; Sowmiya, Govindaraj; Michael, Daliah; Balakrishnan, Narayanasamy; Sekar, Kanagaraj
2008-01-01
Distant repeats in protein sequence play an important role in various aspects of protein analysis. A keen analysis of the distant repeats would enable to establish a firm relation of the repeats with respect to their function and three-dimensional structure during the evolutionary process. Further, it enlightens the diversity of duplication during the evolution. To this end, an algorithm has been developed to find all distant repeats in a protein sequence. The scores from Point Accepted Mutation (PAM) matrix has been deployed for the identification of amino acid substitutions while detecting the distant repeats. Due to the biological importance of distant repeats, the proposed algorithm will be of importance to structural biologists, molecular biologists, biochemists and researchers involved in phylogenetic and evolutionary studies. PMID:19052663
Eigenvalue and eigenvector sensitivity and approximate analysis for repeated eigenvalue problems
NASA Technical Reports Server (NTRS)
Hou, Gene J. W.; Kenny, Sean P.
1991-01-01
A set of computationally efficient equations for eigenvalue and eigenvector sensitivity analysis are derived, and a method for eigenvalue and eigenvector approximate analysis in the presence of repeated eigenvalues is presented. The method developed for approximate analysis involves a reparamaterization of the multivariable structural eigenvalue problem in terms of a single positive-valued parameter. The resulting equations yield first-order approximations of changes in both the eigenvalues and eigenvectors associated with the repeated eigenvalue problem. Examples are given to demonstrate the application of such equations for sensitivity and approximate analysis.
Does Dry Eye Affect Repeatability of Corneal Topography Measurements?
Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay
2018-04-01
The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.
Maxton, Fiona J C; Justin, Linda; Gillies, Donna
2004-01-01
Monitoring temperature in critically ill children is an important component of care, yet the accuracy of methods is often questioned. Temperature measured in the pulmonary artery is considered the 'gold standard', but this route is unsuitable for the majority of patients. An accurate, reliable and less invasive method is, however, yet to be established in paediatric intensive care work. To determine which site most closely reflects core temperature in babies and children following cardiac surgery, by comparing pulmonary artery temperature to the temperature measured at rectal, bladder, nasopharyngeal, axillary and tympanic sites. A convenience sample of 19 postoperative cardiac patients was studied. Temperature was recorded as a continuous measurement from pulmonary artery, rectal, nasopharyngeal and bladder sites. Axillary and tympanic temperatures were recorded at 30 minute intervals for 6 1/2 hours postoperatively. The small sample size of 19 infants and children limits the generalizability of the study. Repeated measures analysis of variance demonstrated no significant difference between pulmonary artery and bladder temperatures, and pulmonary artery and nasopharyngeal temperatures. Intraclass correlation showed that agreement was greatest between pulmonary artery temperature and temperature measured by bladder catheter. There was a significant difference between pulmonary artery temperature and temperature measured at rectal, tympanic and pulmonary artery and axillary sites. Repeated measures analysis showed a significant lag between pulmonary artery and rectal temperature of between 0 and 150 minutes after the 6-hour measurement period. In this study, bladder temperature was shown to be the best estimate of pulmonary artery temperature, closely followed by the temperature measured by nasopharyngeal probe. The results support the use of bladder or nasopharyngeal catheters to monitor temperature in critically ill children after cardiac surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merolle, L., E-mail: lucia.merolle@elettra.eu; Gianoncelli, A.; Malucelli, E., E-mail: emil.malucelli@unibo.it
2016-01-28
Elemental analysis of biological sample can give information about content and distribution of elements essential for human life or trace elements whose absence is the cause of abnormal biological function or development. However, biological systems contain an ensemble of cells with heterogeneous chemistry and elemental content; therefore, accurate characterization of samples with high cellular heterogeneity may only be achieved by analyzing single cells. Powerful methods in molecular biology are abundant, among them X-Ray microscopy based on synchrotron light source has gaining increasing attention thanks to its extremely sensitivity. However, reproducibility and repeatability of these measurements is one of the majormore » obstacles in achieving a statistical significance in single cells population analysis. In this study, we compared the elemental content of human colon adenocarcinoma cells obtained by three distinct accesses to synchrotron radiation light.« less
Digital repeat analysis; setup and operation.
Nol, J; Isouard, G; Mirecki, J
2006-06-01
Since the emergence of digital imaging, there have been questions about the necessity of continuing reject analysis programs in imaging departments to evaluate performance and quality. As a marketing strategy, most suppliers of digital technology focus on the supremacy of the technology and its ability to reduce the number of repeats, resulting in less radiation doses given to patients and increased productivity in the department. On the other hand, quality assurance radiographers and radiologists believe that repeats are mainly related to positioning skills, and repeat analysis is the main tool to plan training needs to up-skill radiographers. A comparative study between conventional and digital imaging was undertaken to compare outcomes and evaluate the need for reject analysis. However, digital technology still being at its early development stages, setting a credible reject analysis program became the major task of the study. It took the department, with the help of the suppliers of the computed radiography reader and the picture archiving and communication system, over 2 years of software enhancement to build a reliable digital repeat analysis system. The results were supportive of both philosophies; the number of repeats as a result of exposure factors was reduced dramatically; however, the percentage of repeats as a result of positioning skills was slightly on the increase for the simple reason that some rejects in the conventional system qualifying for both exposure and positioning errors were classified as exposure error. The ability of digitally adjusting dark or light images reclassified some of those images as positioning errors.
Assessment of different methods to estimate bovine colostrum quality on farm.
Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D
2016-09-01
To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.
Permpongkosol, Sompol; Khupulsup, Kalayanee; Leelaphiwat, Supatra; Pavavattananusorn, Sarawan; Thongpradit, Supranee; Petchthong, Thanom
2016-08-01
The long-term effects of long-acting testosterone undecanoate (TU) and androgen receptor CAG repeat lengths in Thai men with late-onset hypogonadism (LOH) have not been reported. To analyze the 8-year follow-up effects of intramuscular TU therapy on metabolic parameters, urinary symptoms, bone mineral density, and sexual function and investigate CAG repeat lengths in men with LOH. We reviewed the medical records of 428 men with LOH who had been treated with TU and 5 patients were diagnosed with prostate cancer during TU therapy. There were 120 patients (mean age = 65.6 ± 8.9 years) who had 5 to 8 years of continuous TU supplementation and sufficiently completed records for analysis. Genomic DNA was extracted from peripheral blood and the CAG repeat region was amplified by polymerase chain reaction. Fragment analysis, sequencing, electropherography, and chromatography were performed. The main outcome measure was dynamic parameter changes during testosterone supplementation. TU did not improve all obesity parameters. A statistically significant decrease was found in waist circumference, percentage of body fat, glycated hemoglobin, cholesterol, low-density lipoprotein, and International Prostate Symptom Score (P < .05). TU did not produce differences in body mass index, high-density lipoprotein, triglyceride, or the Aging Male Symptoms score from baseline. However, a statistically significant increase was found in the level of testosterone, prostate-specific antigen, hematocrit, International Index of Erectile Function score, and vertebral and femoral bone mineral density (P < .05). No major adverse cardiovascular events or prostate cancer occurred during this study. The CAG repeat length was 14 to 28 and the median CAG length was 22. There was no association between CAG repeat length and any of the anthropometric measurements. Long-term TU treatment in men with LOH for up to 8 years appears to be safe, tolerable, and effective in correcting obesity parameters. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
TRAP: automated classification, quantification and annotation of tandemly repeated sequences.
Sobreira, Tiago José P; Durham, Alan M; Gruber, Arthur
2006-02-01
TRAP, the Tandem Repeats Analysis Program, is a Perl program that provides a unified set of analyses for the selection, classification, quantification and automated annotation of tandemly repeated sequences. TRAP uses the results of the Tandem Repeats Finder program to perform a global analysis of the satellite content of DNA sequences, permitting researchers to easily assess the tandem repeat content for both individual sequences and whole genomes. The results can be generated in convenient formats such as HTML and comma-separated values. TRAP can also be used to automatically generate annotation data in the format of feature table and GFF files.
In-situ investigation of relations between slow slip events, repeaters and earthquake nucleation
NASA Astrophysics Data System (ADS)
Marty, S. B.; Schubnel, A.; Gardonio, B.; Bhat, H. S.; Fukuyama, E.
2017-12-01
Recent observations have shown that, in subduction zones, imperceptible slip, known as "slow slip events", could trigger powerful earthquakes and could be link to the onset of swarms of repeaters. In the aim of investigating the relation between repeaters, slow slip events and earthquake nucleation, we have conducted stick-slip experiments on saw-cut Indian Gabbro under upper crustal stress conditions (up to 180 MPa confining pressure). During the past decades, the reproduction of micro-earthquakes in the laboratory enabled a better understanding and to better constrain physical parameters that are the origin of the seismic source. Using a new set of calibrated piezoelectric acoustic emission sensors and high frequency dynamic strain gages, we are now able to measure a large number of physical parameters during stick-slip motion, such as the rupture velocity, the slip velocity, the dynamic stress drop and the absolute magnitudes and sizes of foreshock acoustic emissions. Preliminary observations systemically show quasi-static slip accelerations, onset of repeaters as well as an increase in the acoustic emission rate before failure. In the next future, we will further investigate the links between slow slip events, repeaters, stress build-up and earthquakes, using our high-frequency acoustic and strain recordings and applying template matching analysis.
Validation of a 3D CT method for measurement of linear wear of acetabular cups.
Jedenmalm, Anneli; Nilsson, Fritjof; Noz, Marilyn E; Green, Douglas D; Gedde, Ulf W; Clarke, Ian C; Stark, Andreas; Maguire, Gerald Q; Zeleznik, Michael P; Olivecrona, Henrik
2011-02-01
We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.
Cavalleri, A; Colombo, C; Venturelli, E; Miceli, R; Mariani, L; Cornelli, U; Pala, V; Berrino, F; Secreto, G
2004-01-01
Measuring the free radical activity in serum samples from prospective studies is the best way to investigate the association between oxidative stress and human diseases. Prospective studies require the analysis of serum samples that have often been stored for a long time. Our study was designed to determine the effect of storage at -30 degrees C and -80 degrees C for two years on free radical activity. We analyzed the free radical activity by measuring circulating hydroperoxides in a pool of sera at baseline and after one day, one week, one month and 25 months of storage, using a photometric method (d-ROMs test). Measurements were performed in aliquots thawed only once at each time point and in aliquots frozen and thawed repeatedly over the study period. After two years we observed a small but statistically significant 4% decrease in the hydroperoxide concentration, which was substantially unaffected by storage temperatures and repeated freeze-thaw cycles. We also carried out the d-ROMs test in sera from ten apparently healthy volunteers at 2, 8, 24, and 48 hours after collection and storage at 4 degrees C and did not observe any significant variation. In conclusion, the d-ROMs test is a simple method suitable to evaluate the free radical activity in frozen serum samples after long-term storage.
Performance evaluation of the microINR® point-of-care INR-testing system.
Joubert, J; van Zyl, M C; Raubenheimer, J
2018-04-01
Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.
Odor measurements according to EN 13725: A statistical analysis of variance components
NASA Astrophysics Data System (ADS)
Klarenbeek, Johannes V.; Ogink, Nico W. M.; van der Voet, Hilko
2014-04-01
In Europe, dynamic olfactometry, as described by the European standard EN 13725, has become the preferred method for evaluating odor emissions emanating from industrial and agricultural sources. Key elements of this standard are the quality criteria for trueness and precision (repeatability). Both are linked to standard values of n-butanol in nitrogen. It is assumed in this standard that whenever a laboratory complies with the overall sensory quality criteria for n-butanol, the quality level is transferable to other, environmental, odors. Although olfactometry is well established, little has been done to investigate inter laboratory variance (reproducibility). Therefore, the objective of this study was to estimate the reproducibility of odor laboratories complying with EN 13725 as well as to investigate the transferability of n-butanol quality criteria to other odorants. Based upon the statistical analysis of 412 odor measurements on 33 sources, distributed in 10 proficiency tests, it was established that laboratory, panel and panel session are components of variance that significantly differ between n-butanol and other odorants (α = 0.05). This finding does not support the transferability of the quality criteria, as determined on n-butanol, to other odorants and as such is a cause for reconsideration of the present single reference odorant as laid down in EN 13725. In case of non-butanol odorants, repeatability standard deviation (sr) and reproducibility standard deviation (sR) were calculated to be 0.108 and 0.282 respectively (log base-10). The latter implies that the difference between two consecutive single measurements, performed on the same testing material by two or more laboratories under reproducibility conditions, will not be larger than a factor 6.3 in 95% of cases. As far as n-butanol odorants are concerned, it was found that the present repeatability standard deviation (sr = 0.108) compares favorably to that of EN 13725 (sr = 0.172). It is therefore suggested that the repeatability limit (r), as laid down in EN 13725, can be reduced from r ≤ 0.477 to r ≤ 0.31.
Seneca, Sara; De Rademaeker, Marjan; Sermon, Karen; De Rycke, Martine; De Vos, Michel; Haentjens, Patrick; Devroey, Paul; Liebaers, Ingeborg
2010-01-01
Purpose This study aims to analyze the relationship between trinucleotide repeat length and reproductive outcome in a large cohort of DM1 patients undergoing ICSI and PGD. Methods Prospective cohort study. The effect of trinucleotide repeat length on reproductive outcome per patient was analyzed using bivariate analysis (T-test) and multivariate analysis using Kaplan-Meier and Cox regression analysis. Results Between 1995 and 2005, 205 cycles of ICSI and PGD were carried out for DM1 in 78 couples. The number of trinucleotide repeats does not have an influence on reproductive outcome when adjusted for age, BMI, basal FSH values, parity, infertility status and male or female affected. Cox regression analysis indicates that cumulative live birth rate is not influenced by the number of trinucleotide repeats. The only factor with a significant effect is age (p < 0.05). Conclusion There is no evidence of an effect of trinucleotide repeat length on reproductive outcome in patients undergoing ICSI and PGD. PMID:20221684
Measuring Femoral Torsion In Vivo Using Freehand 3-D Ultrasound Imaging.
Passmore, Elyse; Pandy, Marcus G; Graham, H Kerr; Sangeux, Morgan
2016-02-01
Despite variation in bone geometry, muscle and joint function is often investigated using generic musculoskeletal models. Patient-specific bone geometry can be obtained from computerised tomography, which involves ionising radiation, or magnetic resonance imaging (MRI), which is costly and time consuming. Freehand 3-D ultrasound provides an alternative to obtain bony geometry. The purpose of this study was to determine the accuracy and repeatability of 3-D ultrasound in measuring femoral torsion. Measurements of femoral torsion were performed on 10 healthy adults using MRI and 3-D ultrasound. Measurements of femoral torsion from 3-D ultrasound were, on average, smaller than those from MRI (mean difference = 1.8°; 95% confidence interval: -3.9°, 7.5°). MRI and 3-D ultrasound had Bland and Altman repeatability coefficients of 3.1° and 3.7°, respectively. Accurate measurements of femoral torsion were obtained with 3-D ultrasound offering the potential to acquire patient-specific bone geometry for musculoskeletal modelling. Three-dimensional ultrasound is non-invasive and relatively inexpensive and can be integrated into gait analysis. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Burt, Dean; Lamb, Kevin; Nicholas, Ceri; Twist, Craig
2015-07-01
This study examined whether lower-volume exercise-induced muscle damage (EIMD) performed 2 weeks before high-volume muscle-damaging exercise protects against its detrimental effect on running performance. Sixteen male participants were randomly assigned to a lower-volume (five sets of ten squats, n = 8) or high-volume (ten sets of ten squats, n = 8) EIMD group and completed baseline measurements for muscle soreness, knee extensor torque, creatine kinase (CK), a 5-min fixed-intensity running bout and a 3-km running time-trial. Measurements were repeated 24 and 48 h after EIMD, and the running time-trial after 48 h. Two weeks later, both groups repeated the baseline measurements, ten sets of ten squats and the same follow-up testing (Bout 2). Data analysis revealed increases in muscle soreness and CK and decreases in knee extensor torque 24-48 h after the initial bouts of EIMD. Increases in oxygen uptake [Formula: see text], minute ventilation [Formula: see text] and rating of perceived exertion were observed during fixed-intensity running 24-48 h after EIMD Bout 1. Likewise, time increased and speed and [Formula: see text] decreased during a 3-km running time-trial 48 h after EIMD. Symptoms of EIMD, responses during fixed-intensity and running time-trial were attenuated in the days after the repeated bout of high-volume EIMD performed 2 weeks after the initial bout. This study demonstrates that the protective effect of lower-volume EIMD on subsequent high-volume EIMD is transferable to endurance running. Furthermore, time-trial performance was found to be preserved after a repeated bout of EIMD.
Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer
Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure
2015-01-01
Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375
Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.
Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure
2015-01-01
Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.
Alsufiani, Hadeil M; Yamani, Fatmah; Kumosani, Taha A; Ford, Dianne; Mathers, John C
2015-04-01
To assess the relative validity and repeatability of a sixty-four-item FFQ for estimating dietary intake of Zn and its absorption modifiers in Saudi adults. In addition, we used the FFQ to investigate the effect of age and gender on these intakes. To assess validity, all participants completed the FFQ (FFQ1) and a 3 d food record. After 1 month, the FFQ was administered for a second time (FFQ2) to assess repeatability. Jeddah, Saudi Arabia. One hundred males and females aged 20-30 years and 60-70 years participated. Mean intakes of Zn and protein from FFQ1 were significantly higher than those from the food record while there were no detectable differences between tools for measurement of phytic acid intake. Estimated intakes of Zn, protein and phytate by both approaches were strongly correlated (P<0·001). Bland-Altman analysis showed for protein that the difference in intake as measured by the two methods was similar across the range of intakes while for Zn and phytic acid, the difference increased with increasing mean intake. Zn and protein intakes from FFQ1 and FFQ2 were highly correlated (r>0·68, P<0·001) but were significantly lower at the second measurement (FFQ2). Older adults consumed less Zn and protein compared with young adults. Intakes of all dietary components were lower in females than in males. The FFQ developed and tested in the current study demonstrated reasonable relative validity and high repeatability and was capable of detecting differences in intakes between age and gender groups.
Setterbo, J J; Fyhrie, P B; Hubbard, M; Upadhyaya, S K; Stover, S M
2013-01-01
Racetrack surface is a risk factor for Thoroughbred racehorse injury and death that can be engineered and managed. To investigate the relationship between surface and injury, the mechanical behaviour of dirt and synthetic track surfaces must be quantified. To compare dynamic properties of a dirt and a synthetic surface in situ using a track-testing device designed to simulate equine hoof impact; and to determine the effects of impact velocity, impact angle and repeated impact on dynamic surface behaviour. A track-testing device measured force and displacement during impact into a dirt and a synthetic surface at 3 impact velocities (1.91, 2.30, 2.63 m/s), 2 impact angles (0°, 20° from vertical), and 2 consecutive impacts (initial, repeat). Surfaces were measured at 3 locations/day for 3 days. The effects of surface type, impact velocity, impact angle and impact number on dynamic surface properties were assessed using analysis of variance. Synthetic surface maximum forces, load rates and stiffnesses were 37-67% of dirt surface values. Surfaces were less stiff with lower impact velocities, angled impacts and initial impacts. The magnitude of differences between dirt and synthetic surfaces increased for repeat impacts and higher impact velocities. The synthetic surface was generally softer than the dirt surface. Greatly increased hardness for repeat impacts corroborates the importance of maintenance. Results at different impact velocities suggest that surface differences will persist at higher impact velocities. For both surfaces it is clearly important to prevent horse exposure to precompacted surfaces, particularly during high-speed training when the surface has already been trampled. These data should be useful in coordinating racetrack surface management with racehorse training to prevent injuries. © 2012 EVJ Ltd.
Brehm, Susan Baker; Weinrich, Barbara D; Sprouse, Dana C; May, Shelley K; Hughes, Michael R
2012-11-01
The purpose of this study was to determine the effect of task type on fundamental frequency (F(0)) and the short-term repeatability of average airflow values in preschool/kindergarten-age children. Prospective, experimental. Thirty healthy children (age 4.0-5.11 years) were included in this study. Participants completed three tasks (sustained vowel, counting, and storytelling) used to elicit measurements of F(0). With a 10-minute interval, participants also completed two trials of sustained /a/ at a comfortable pitch and loudness level for the measurement of average airflow rate. F(0) and intensity of the vowel production were recorded for both trials. A repeated measures analysis of variance revealed a significant main effect for task type elicitation on F(0) values (P=0.0003). A significant difference between elicitation tasks for F(0) was observed in the comparison of the counting and storytelling task (P<0.0001). A paired t test revealed no significant difference in average airflow rate across two trials (P=0.872). The change in F(0) and intensity was measured across the trials, and separate analyses of covariance revealed that these changes did not significantly influence average airflow values, (P=0.809) and (P=0.365), respectively. The results of this study demonstrated that F(0) may be influenced by task type in young children. Average airflow values appear to be stable over a short time period. This information is important in determining methods of evaluation and the reliability of instrumental measures in young children with voice disorders. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Vieira, Alan Araujo; Soares, Fernanda Valente Mendes; Pimenta, Hellen Porto; Abranches, Andrea Dunshee; Moreira, Maria Elisabeth Lopes
2011-08-01
The macronutrient concentrations of human milk could be influenced by the various processes used in human milk bank. To determine the effect of various process (Holder pasteurization, freezing and thawing and feeding method) on the macronutrient concentration of human milk. The samples of donated fresh human milk were studied before and after each process (Holder pasteurization, freezing and thawing and feeding method) until their delivery to newborn infants. Fifty-seven raw human milk samples were analyzed in the first step (pasteurization) and 228 in the offer step. Repeated measurements of protein, fat and lactose amounts were made in samples of human milk using an Infrared analyzer. The influence of repeated processes on the mean concentration of macronutrients in donor human milk was analyzed by repeated measurements ANOVA, using R statistical package. The most variable macronutrient concentration in the analyzed samples was fat (reduction of 59%). There was a significant reduction of fat and protein mean concentrations following pasteurization (5.5 and 3.9%, respectively). The speed at which the milk was thawed didn't cause a significant variation in the macronutrients concentrations. However, the continuous infusion delivery significantly reduced the fat concentration. When the influence of repeated processes was analyzed, the fat and protein concentrations varied significantly (reduction of 56.6% and 10.1% respectively) (P<0.05). Lactose didn't suffer significant reductions in all steps. The repeated processes that donor human milk is submitted before delivery to newborn infants cause a reduction in the fat and protein concentration. The magnitude of this decrease is higher on the fat concentration and it needs to be considered when this processed milk is used to feed preterm infants. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Spencer, Kevin; Cuckle, Howard S
2002-10-01
To assess the within person biological variability of first trimester maternal serum biochemical markers of trisomy 21 across the 10-14 week gestational period. To evaluate whether repeat sampling and testing of free beta-hCG and PAPP-A during this period would result in an improved detection rate. Women presenting at the first trimester OSCAR clinic have blood collected prior to ultrasound dating and nuchal translucency measurement. All samples are analysed for free beta-hCG and PAPP-A before an accurate estimate of gestation is available. In 10% of cases the gestation is prior to the minimum time for NT measurement (11 weeks) and these women are rebooked for a repeat visit to the clinic at the appropriate time. Our fetal database was interrogated to obtain cases in which two maternal blood samples had been collected and analysed in the 10-14 week period. Using data from the marker correlations and statistical modelling, the impact of repeat testing on detection rate for trisomy 21 at a fixed 5% false positive rate, was assessed. 261 pairs of data were available for analysis collected over a 3 year period. The correlation between free beta-hCG in sample 1 and sample 2 was 0.890 and that for PAPP-A was 0.827. The average within person biological variation for free beta-hCG was 21% and 32% for PAPP-A. The increase in detection rate when using both sets of marker data was 3.5% when using serum biochemistry and maternal age, and 1.3% when using nuchal translucency, serum biochemistry and maternal age. Repeat sampling and testing of maternal serum biochemical markers is unlikely to substantially improve first trimester screening performance. Copyright 2002 John Wiley & Sons, Ltd.
Duffield, Rob; Portus, Marc
2007-07-01
To compare the effects of three types of full-body compression garments (Skins, Adidas and Under Armour) on repeat-sprint and throwing performance in cricket players. Following familiarisation, 10 male cricket players performed four randomised exercise sessions (3 garments and a control). Each session involved a 30 min repeat-sprint exercise protocol comprising 20 m sprints every minute, separated by submaximal exercise. Throwing tests included a pre-exercise and a postexercise maximal distance test and accuracy throwing tests. During each session, measures of heart rate, skin temperature, change in body mass, rate of perceived exertion and perceived muscle soreness were recorded. Capillary blood samples were analysed before and after exercise for lactate, pH, O(2) saturation and O(2) partial pressure, and 24 h after exercise for creatine kinase (CK). Ratings of perceived muscle soreness were also obtained 24 h after exercise. No significant differences (p>0.05) were evident in repeat-sprint performance (10 m, 20 m time or total submaximal distance covered) or throwing performance (maximum distance or accuracy). No significant differences (p>0.05) were observed in heart rate, body mass change or blood measures during exercise. Significant differences (p<0.05) were observed by way of higher mean skin temperature, lower 24 h postexercise CK values and lower 24 h postexercise ratings of muscle soreness when wearing compression garments. Analysis between respective brands of compression garments revealed no statistical differences (p>0.05). No benefit was noted when wearing compression garments for repeat-sprint or throwing performance; however, the use of the garments as a recovery tool, when worn after exercise, may be beneficial to reduce postexercise trauma and perceived muscle soreness.
Preliminary analysis of STS-2 entry flight data
NASA Technical Reports Server (NTRS)
1982-01-01
A preliminary analysis of the data obtained during the entry of the STS-2 flight was completed. The stability and control derivatives from STS-2 were examined. Questions still remain throughout the flight envelope and the area below Mach 3 needs more study. With three controls operating in a high gain feedback system, it is difficult to separate the individual effects of each of the controls. Analysis of the aerothermal data shows that wing structural-temperature measurements are generally repeatable and consistent with the trajectories. The measured wing upper surface temperatures are in reasonable agreement with Dryden predictions but wing lower surface temperatures are higher than Dryden predictions. Heating and heat transfer models will be adjusted to improve the temperature prediction capability for future trajectories.
Motion based parsing for video from observational psychology
NASA Astrophysics Data System (ADS)
Kokaram, Anil; Doyle, Erika; Lennon, Daire; Joyeux, Laurent; Fuller, Ray
2006-01-01
In Psychology it is common to conduct studies involving the observation of humans undertaking some task. The sessions are typically recorded on video and used for subjective visual analysis. The subjective analysis is tedious and time consuming, not only because much useless video material is recorded but also because subjective measures of human behaviour are not necessarily repeatable. This paper presents tools using content based video analysis that allow automated parsing of video from one such study involving Dyslexia. The tools rely on implicit measures of human motion that can be generalised to other applications in the domain of human observation. Results comparing quantitative assessment of human motion with subjective assessment are also presented, illustrating that the system is a useful scientific tool.
Effect of repeat copy number on variable-number tandem repeat mutations in Escherichia coli O157:H7.
Vogler, Amy J; Keys, Christine; Nemoto, Yoshimi; Colman, Rebecca E; Jay, Zack; Keim, Paul
2006-06-01
Variable-number tandem repeat (VNTR) loci have shown a remarkable ability to discriminate among isolates of the recently emerged clonal pathogen Escherichia coli O157:H7, making them a very useful molecular epidemiological tool. However, little is known about the rates at which these sequences mutate, the factors that affect mutation rates, or the mechanisms by which mutations occur at these loci. Here, we measure mutation rates for 28 VNTR loci and investigate the effects of repeat copy number and mismatch repair on mutation rate using in vitro-generated populations for 10 E. coli O157:H7 strains. We find single-locus rates as high as 7.0 x 10(-4) mutations/generation and a combined 28-locus rate of 6.4 x 10(-4) mutations/generation. We observed single- and multirepeat mutations that were consistent with a slipped-strand mispairing mutation model, as well as a smaller number of large repeat copy number mutations that were consistent with recombination-mediated events. Repeat copy number within an array was strongly correlated with mutation rate both at the most mutable locus, O157-10 (r2= 0.565, P = 0.0196), and across all mutating loci. The combined locus model was significant whether locus O157-10 was included (r2= 0.833, P < 0.0001) or excluded (r2= 0.452, P < 0.0001) from the analysis. Deficient mismatch repair did not affect mutation rate at any of the 28 VNTRs with repeat unit sizes of >5 bp, although a poly(G) homomeric tract was destabilized in the mutS strain. Finally, we describe a general model for VNTR mutations that encompasses insertions and deletions, single- and multiple-repeat mutations, and their relative frequencies based upon our empirical mutation rate data.
Evolution of Protein Domain Repeats in Metazoa
Schüler, Andreas; Bornberg-Bauer, Erich
2016-01-01
Repeats are ubiquitous elements of proteins and they play important roles for cellular function and during evolution. Repeats are, however, also notoriously difficult to capture computationally and large scale studies so far had difficulties in linking genetic causes, structural properties and evolutionary trajectories of protein repeats. Here we apply recently developed methods for repeat detection and analysis to a large dataset comprising over hundred metazoan genomes. We find that repeats in larger protein families experience generally very few insertions or deletions (indels) of repeat units but there is also a significant fraction of noteworthy volatile outliers with very high indel rates. Analysis of structural data indicates that repeats with an open structure and independently folding units are more volatile and more likely to be intrinsically disordered. Such disordered repeats are also significantly enriched in sites with a high functional potential such as linear motifs. Furthermore, the most volatile repeats have a high sequence similarity between their units. Since many volatile repeats also show signs of recombination, we conclude they are often shaped by concerted evolution. Intriguingly, many of these conserved yet volatile repeats are involved in host-pathogen interactions where they might foster fast but subtle adaptation in biological arms races. Key Words: protein evolution, domain rearrangements, protein repeats, concerted evolution. PMID:27671125
Measuring Technological and Content Knowledge of Undergraduate Primary Teachers in Mathematics
NASA Astrophysics Data System (ADS)
Doukakis, Spyros; Chionidou-Moskofoglou, Maria; Mangina-Phelan, Eleni; Roussos, Petros
Twenty-five final-year undergraduate students of primary education who were attending a course on mathematics education participated in a research project during the 2009 spring semester. A repeated measures experimental design was used. Quantitative data on students' computer attitudes, self-efficacy in ICT, attitudes toward educational software, and self-efficacy in maths were collected. Data analysis showed a statistically non-significant improvement on participants' computer attitudes and self-efficacy in ICT and ES, but a significant improvement of self-efficacy in mathematics.
Helicopter noise measurements repeatability program final report
DOT National Transportation Integrated Search
1987-09-01
This report summarizes the findings of the Helicopter Noise Measurement Repeatability Program (HNMRP), which was initiated by the International Civil Aviation Organization (ICAO) Committee on Aviation Environmental Protection (CAEP) Working Group II ...
The Beast of Aggregating Cognitive Load Measures in Technology-Based Learning
ERIC Educational Resources Information Center
Leppink, Jimmie; van Merriënboer, Jeroen J. G.
2015-01-01
An increasing part of cognitive load research in technology-based learning includes a component of repeated measurements, that is: participants are measured two or more times on the same performance, mental effort or other variable of interest. In many cases, researchers aggregate scores obtained from repeated measurements to one single sum or…
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Trecker, Molly A; Dillon, Jo-Anne R; Lloyd, Kathy; Hennink, Maurice; Jolly, Ann; Waldner, Cheryl
2017-06-01
Saskatchewan has one of the highest rates of gonorrhea among the Canadian provinces-more than double the national rate. In light of these high rates, and the growing threat of untreatable infections, improved understanding of gonorrhea transmission dynamics in the province and evaluation of the current system and tools for disease control are important. We extracted data from a cross-sectional sample of laboratory-confirmed gonorrhea cases between 2003 and 2012 from the notifiable disease files of the Regina Qu'Appelle Health Region. The database was stratified by calendar year, and social network analysis combined with statistical modeling was used to identify associations between measures of connection within the network and the odds of repeat gonorrhea and risk of coinfection with chlamydia at the time of diagnosis. Networks were highly fragmented. Younger age and component size were positively associated with being coinfected with chlamydia. Being coinfected, reporting sex trade involvement, and component size were all positively associated with repeat infection. This is the first study to apply social network analysis to gonorrhea transmission in Saskatchewan and contributes important information about the relationship of network connections to gonorrhea/chlamydia coinfection and repeat gonorrhea. This study also suggests several areas for change of systems-related factors that could greatly increase understanding of social networks and enhance the potential for bacterial sexually transmitted infection control in Saskatchewan.
NASA Astrophysics Data System (ADS)
Bobovnik, G.; Kutin, J.; Bajsić, I.
2016-08-01
This paper deals with an uncertainty analysis of gas flow measurements using a compact, high-speed, clearance-sealed realization of a piston prover. A detailed methodology for the uncertainty analysis, covering the components due to the gas density, dimensional and time measurements, the leakage flow, the density correction factor and the repeatability, is presented. The paper also deals with the selection of the isothermal and adiabatic measurement models, the treatment of the leakage flow and discusses the need for averaging multiple consecutive readings of the piston prover. The analysis is prepared for the flow range (50 000:1) covered by the three interchangeable flow cells. The results show that using the adiabatic measurement model and averaging the multiple readings, the estimated expanded measurement uncertainty of the gas mass flow rate is less than 0.15% in the flow range above 0.012 g min-1, whereas it increases for lower mass flow rates due to the leakage flow related effects. At the upper end of the measuring range, using the adiabatic instead of the isothermal measurement model, as well as averaging multiple readings, proves important.
DOT National Transportation Integrated Search
1985-09-30
This document reports the findings of the U.S. test team's participation in the Helicopter Noise Measurement Repeatability Program (HNMRP) conducted under the direction of the International Civil Aviation Organization's (ICAO) Committee on Aviation E...
Kaartokallio, Tea; Utge, Siddheshwar; Klemetti, Miira M; Paananen, Jussi; Pulkki, Kari; Romppanen, Jarkko; Tikkanen, Ilkka; Heinonen, Seppo; Kajantie, Eero; Kere, Juha; Kivinen, Katja; Pouta, Anneli; Lakkisto, Päivi; Laivuori, Hannele
2018-01-01
Preeclampsia is a vascular pregnancy disorder that often involves impaired placental development. HO-1 (heme oxygenase 1, encoded by HMOX1 ) is a stress response enzyme crucial for endothelial and placental function. Long version of the guanine-thymine (GT n ) microsatellite in the HMOX1 promoter decreases HO-1 expression, and the long maternal repeat is associated with late-onset preeclampsia. Our aim was to study whether the length of fetal repeat is associated with mother's preeclampsia, whether the length of fetal and maternal repeats affect HO-1 levels in placenta and maternal serum, and whether HO-1 levels are altered in preeclampsia. We genotyped the repeat in the cord blood of 609 preeclamptic and 745 nonpreeclamptic neonates. HO-1 levels were measured in 36 placental samples, and in the first (222 cases/243 controls) and third (176 cases/53 controls) pregnancy trimester serum samples using enzyme-linked immunosorbent assay. The long fetal GT n repeat was associated with preeclampsia and its severe and early-onset subtypes. Interaction analysis suggested the maternal and fetal effects to be independent. Placental or serum HO-1 levels were not altered in preeclamptics, possibly reflecting heterogeneity of preeclampsia. Carriers of the long fetal and maternal repeats had lower placental and serum HO-1 levels, respectively, providing functional evidence for the association. We conclude that the long fetal GT n repeat may increase mother's risk for especially severe and early-onset preeclampsia. The fetal and maternal risk alleles likely predispose to different disease subtypes. © 2017 American Heart Association, Inc.
A Fracture Mechanics Approach to Thermal Shock Investigation in Alumina-Based Refractory
NASA Astrophysics Data System (ADS)
Volkov-Husović, T.; Heinemann, R. Jančić; Mitraković, D.
2008-02-01
The thermal shock behavior of large grain size, alumina-based refractories was investigated experimentally using a standard water quench test. A mathematical model was employed to simulate the thermal stability behavior. Behavior of the samples under repeated thermal shock was monitored using ultrasonic measurements of dynamic Young's modulus. Image analysis was used to observe the extent of surface degradation. Analysis of the obtained results for the behavior of large grain size samples under conditions of rapid temperature changes is given.
Mission design concepts for repeat groundtrack orbits and application to the ICESat mission
NASA Astrophysics Data System (ADS)
Pie, Nadege
The primary objective of the NASA sponsored ICESat mission is to study the short and long term changes in the ice mass in the Greenland and Antarctica regions. The satellite was therefore placed into a frozen near-polar near-circular repeat groundtrack to ensure an adequate coverage of the polar regions while keeping the groundtrack periodic and reducing the variations in the orbital elements, and more specifically the semi-major axis of the ICESat orbit. After launch, a contingency plan had to be devised to compensate for a laser that dangerously compromised the lifetime of the ICESat mission. This new plan makes an intensive use of the ICESat subcycles, a characteristic of the repeat groundtrack orbits often over-looked. The subcycle of a repeat groundtrack orbit provide global coverage within a time shorter than the groundtrack repetition period. For a satellite with an off-nadir pointing capacity, the subcycles provide near-repeat tracks which represents added opportunity for altimetry measurement over a specific track. The ICESat subcycles were also used in a very innovative fashion to reposition the satellite within its repeat cycle via orbital maneuvers called phasing maneuver. The necessary theoretical framework is provided for the subcycle analysis and the implementation of phasing maneuvers for any future repeat orbit mission. In the perspective of performing cross-validation of missions like CryoSat using the ICESat off-nadir capacity, a study was conducted to determine the geolocations of crossovers between two different repeat groundtrack Keplerian orbits. The general analytical solution was applied to ICESat vs. several other repeat groundtrack orbit mission, including the future ICESat-II mission. ICESat's repeat groundtrack orbit was designed using a disturbing force model that includes only the Earth geopotential. Though the third body effect from the Sun and the Moon was neglected in the orbit design, it does in fact disrupt the repeatability condition of the groundtrack and consequently implies orbit correction maneuvers. The perturbations on ICESat orbit due to the third body effect are studied as a preliminary work towards including these forces in the design of the future ICESat-II repeat groundtrack orbit.
Beyond the Rainbow: Retrieval Practice Leads to Better Spelling than Does Rainbow Writing
ERIC Educational Resources Information Center
Jones, Angela C.; Wardlow, Liane; Pan, Steven C.; Zepeda, Cristina; Heyman, Gail D.; Dunlosky, John; Rickard, Timothy C.
2016-01-01
In three experiments, we compared the effectiveness of rainbow writing and retrieval practice, two common methods of spelling instruction. In experiment 1 (n = 14), second graders completed 2 days of spelling practice, followed by spelling tests 1 day and 5 weeks later. A repeated measures analysis of variance demonstrated that spelling accuracy…
Measurement repeatability of a large-scale inventory of forest fuels
J.A. Westfall; C.W. Woodall
2007-01-01
An efficient and accurate inventory of forest fuels at large scales is critical for assessment of forest fire hazards across landscapes. The Forest Inventory and Analysis (FIA) program of the USDA Forest Service conducts a national inventory of fuels along with blind remeasurement of a portion of inventory plots to monitor and improve data quality. The goal of this...
2006-06-01
measurement. The Lancet, 1, 307-3 10. Boxer Wachler, B.S. (2003). Effect of pupil size on visual function under monocular and binocular conditions in LASIK ...and non- LASIK patients. J Cataract Refract Surg, 29 (2), 275- 278. Boxer Wachler, B.S., Huynh, V.N., El-Shiaty, A.F., & Goldberg, D. (2002
Gino Graziano; Paul Twardock; Rusty Myers; Roman Dial; David Scheel
2007-01-01
Human waste disposal is a health concern in many backcountry areas. This study measured Clostridium perfringens in beach sediments of Prince William Sound, Alaska, to detect fecal contamination resulting from intertidal disposal. Analysis involved holding times that exceeded eight hours. In repeatedly sampled stored sediments, C. perfringens...
NASA Technical Reports Server (NTRS)
Ploutz-Snyder, R. J.; Feiveson, A. H.
2015-01-01
Back by popular demand, the JSC Biostatistics Lab is offering an opportunity for informal conversation about challenges you may have encountered with issues of experimental design, analysis, data visualization or related topics. Get answers to common questions about sample size, repeated measures, violation of distributional assumptions, missing data, multiple testing, time-to-event data, when to trust the results of your analyses (reproducibility issues) and more.
Shishani, Kawkab; Howell, Donelle; McPherson, Sterling; Roll, John
2014-06-01
The purpose of this pilot study was to investigate smoking behaviors and subjective and physiological effects of nicotine on young adult occasional waterpipe smokers. This study utilized a repeated-measures design that included one repeated factor for condition (nicotine and non-nicotine). For each participant, the sequencing of the repeated factor was assigned using random allocation. The two nicotine conditions were nicotine (0.75 g) and non-nicotine (0 g placebo) tobacco. Over the course of two weeks, twenty-two participants completed subjective (Acute Subjective Effects of Nicotine) and physiological (blood pressure, heart rate, and CO level) measures. Additional measures (QSU and MNWS-R) were used to assess for withdrawal symptoms. The participants (n=22) were young adults (23 ± 3.1years); 71% smoked waterpipe once a month in the past year and 29% smoked waterpipe 1-2 times per week. In addition, 60% reported sharing their waterpipe with friends while smoking. None of the participants reported using any other forms of tobacco products. Under the nicotine condition, participants tended to smoke longer (i.e. smoking duration, p=0.004), take more puffs (p=0.03), take shorter puffs (p=0.03), and inhale less volume with each puff (p=0.02). The repeated measures analysis of the factor headrush revealed an effect of the nicotine condition (F=9.69, p<0.001, partial η(2)=0.31) and time (F=8.17, p=0.02, partial η(2)=0.30). Heart rate increased significantly across the nicotine condition (F=7.92, p=0.01, partial η(2)=0.31) and over time (F=12.64, p=0.01, partial η(2)=0.41). This study demonstrates how differences between nicotine and non-nicotine waterpipe smoking are associated with changes in smoking behaviors, experiencing a headrush and an increase in heart rate. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Takei, Keiichi; Yamamoto, Mitsuru
2017-01-01
Background: Throwing athletes risk medial elbow injury from extreme valgus stress generated across the medial elbow during throwing. Braces have been developed to protect the elbow joint; however, no previous study has investigated the effects of elbow bracing on medial elbow joint space gapping associated with repetitive throwing. Hypothesis/Purpose: The purpose of this study was to investigate the effects of elbow bracing on medial elbow joint space gapping during repetitive throwing. Our hypothesis was that an elbow brace may reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. Study Design: Controlled laboratory study. Methods: Twenty-five high school baseball players participated in this study. Each subject pitched 100 times under 2 conditions: control (without elbow brace) and elbow brace. The ulnohumeral joint space was measured ultrasonically before pitching and after every block of 20 pitches. Measurement of the ulnohumeral joint space was carried out using ultrasound with the forearm hanging by the side. Two-way repeated-measures analysis of variance and post hoc tests were used to compare ulnohumeral joint space with repeated pitching and between the elbow brace and control conditions. Results: In the control condition, ulnohumeral joint space after 60 pitches was significantly greater than that before pitching (P < .01). In contrast, in the elbow brace condition, ulnohumeral joint space was not significantly different after repeated pitching. When comparing these 2 conditions, ulnohumeral joint space in the control condition was significantly greater than that in the elbow brace condition after 60 pitches (P < .01). Conclusion: An elbow brace has the effect of preventing medial elbow joint space gapping with repeated throwing when determined ultrasonically by measuring the ulnohumeral joint space under gravity load. Clinical Relevance: An elbow brace worn during baseball pitching practice may help reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. PMID:28451622
Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Takei, Keiichi; Yamamoto, Mitsuru
2017-04-01
Throwing athletes risk medial elbow injury from extreme valgus stress generated across the medial elbow during throwing. Braces have been developed to protect the elbow joint; however, no previous study has investigated the effects of elbow bracing on medial elbow joint space gapping associated with repetitive throwing. The purpose of this study was to investigate the effects of elbow bracing on medial elbow joint space gapping during repetitive throwing. Our hypothesis was that an elbow brace may reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. Controlled laboratory study. Twenty-five high school baseball players participated in this study. Each subject pitched 100 times under 2 conditions: control (without elbow brace) and elbow brace. The ulnohumeral joint space was measured ultrasonically before pitching and after every block of 20 pitches. Measurement of the ulnohumeral joint space was carried out using ultrasound with the forearm hanging by the side. Two-way repeated-measures analysis of variance and post hoc tests were used to compare ulnohumeral joint space with repeated pitching and between the elbow brace and control conditions. In the control condition, ulnohumeral joint space after 60 pitches was significantly greater than that before pitching ( P < .01). In contrast, in the elbow brace condition, ulnohumeral joint space was not significantly different after repeated pitching. When comparing these 2 conditions, ulnohumeral joint space in the control condition was significantly greater than that in the elbow brace condition after 60 pitches ( P < .01). An elbow brace has the effect of preventing medial elbow joint space gapping with repeated throwing when determined ultrasonically by measuring the ulnohumeral joint space under gravity load. An elbow brace worn during baseball pitching practice may help reduce mechanical stress on the elbow by reducing medial elbow joint space gapping.
McCullough, Elaine; Gordon-Jones, Susi; Last, Anna; Vaughan, Jay; Burnell, Alan
2016-10-01
Research into the effectiveness of therapeutic interventions for older children who have experienced multiple forms of trauma within the context of their early development is scant. This article explores the effectiveness of Neuro-Physiological Psychotherapy (NPP): a wrap-around multi-disciplinary, neuro-sequential, attachment-focussed intervention for children and families who present with multiple, clinically significant, emotional and behavioural difficulties. In total, 31 young people and their adoptive parents took part in the study. Baseline measures were repeated and parents and children interviewed. An assessment of the parent/child relationship and child attachment was undertaken but not analysed for this article. Analysis of the repeated measures received statistically significant changes in behavioural regulation, metacognitive executive functioning and externalising and internalising difficulties, alongside an improvement in thought and social problems. An analysis of the parent interviews provided positive results in terms of the children's engagement in education, an absence of further mental health diagnosis or involvement in the criminal justice system. Further hypotheses are posited regarding the impact of the treatment and further research into the effectiveness of the model outlined. © The Author(s) 2016.
Caneppele, Taciana Marco Ferraz; Rocha Gomes Torres, Carlos; Bresciani, Eduardo
2015-10-01
The aim of this study was to evaluate the effect of hydrogen peroxide whitening on fluorescence and color of bovine enamel and dentin. Twenty five dentin discs and 25 enamel discs, with 6 mm diameter and 1 mm thick, were obtained. Direct fluorescence (spectrofluorophotometry) and color (spectrophotometry) were assessed. After fluorescence and color baseline measurements, specimens were immersed in a 35% hydrogen peroxide (HP) solution for 1 h. This procedure was repeated after 7 days. Final fluorescence and color measurements were performed after the second immersion. Chemical characterization of 5 additional specimens was also performed. Data were submitted to repeated analysis of variance and Tukey's test for fluorescence and unpaired t-test for color and chemical components (p<0.05). Fluorescence decreased significantly in dentin specimens after whitening. Enamel presented lower fluorescence than dentin at baseline, but this parameter did not decrease after whitening. Color changes were observed for both substrates, with significantly greater whitening effect in dentin (ΔE=10.37) (p<0.001). Whitening by hydrogen peroxide induced significant decrease in fluorescence of tooth dentin and promoted significant color changes in dentin and enamel with more accentuated outcomes in dentin.
Forooghian, Farzin; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T
2008-10-01
To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular subfields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CR(W)), and coefficients of variation (CV(W)) were used to assess intrasession repeatability. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 microm and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CR(W), CV(W), and ICC. Repeatability measures (CR(W) and CV(W)) differed significantly between systems in only one of nine subfields (outer temporal subfield). Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.
Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta
2012-02-01
Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.
Tandem-repeat protein domains across the tree of life.
Jernigan, Kristin K; Bordenstein, Seth R
2015-01-01
Tandem-repeat protein domains, composed of repeated units of conserved stretches of 20-40 amino acids, are required for a wide array of biological functions. Despite their diverse and fundamental functions, there has been no comprehensive assessment of their taxonomic distribution, incidence, and associations with organismal lifestyle and phylogeny. In this study, we assess for the first time the abundance of armadillo (ARM) and tetratricopeptide (TPR) repeat domains across all three domains in the tree of life and compare the results to our previous analysis on ankyrin (ANK) repeat domains in this journal. All eukaryotes and a majority of the bacterial and archaeal genomes analyzed have a minimum of one TPR and ARM repeat. In eukaryotes, the fraction of ARM-containing proteins is approximately double that of TPR and ANK-containing proteins, whereas bacteria and archaea are enriched in TPR-containing proteins relative to ARM- and ANK-containing proteins. We show in bacteria that phylogenetic history, rather than lifestyle or pathogenicity, is a predictor of TPR repeat domain abundance, while neither phylogenetic history nor lifestyle predicts ARM repeat domain abundance. Surprisingly, pathogenic bacteria were not enriched in TPR-containing proteins, which have been associated within virulence factors in certain species. Taken together, this comparative analysis provides a newly appreciated view of the prevalence and diversity of multiple types of tandem-repeat protein domains across the tree of life. A central finding of this analysis is that tandem repeat domain-containing proteins are prevalent not just in eukaryotes, but also in bacterial and archaeal species.
Ha, Jae Wook; Couper, David J.; O’Neal, Wanda K.; Barr, R. Graham; Bleecker, Eugene R.; Carretta, Elizabeth E.; Cooper, Christopher B.; Doerschuk, Claire M.; Drummond, M Bradley; Han, MeiLan K.; Hansel, Nadia N.; Kim, Victor; Kleerup, Eric C.; Martinez, Fernando J.; Rennard, Stephen I.; Tashkin, Donald; Woodruff, Prescott G.; Paine, Robert; Curtis, Jeffrey L.; Kanner, Richard E.
2017-01-01
Rationale Understanding the reliability and repeatability of clinical measurements used in the diagnosis, treatment and monitoring of disease progression is of critical importance across all disciplines of clinical practice and in clinical trials to assess therapeutic efficacy and safety. Objectives Our goal is to understand normal variability for assessing true changes in health status and to more accurately utilize this data to differentiate disease characteristics and outcomes. Methods Our study is the first study designed entirely to establish the repeatability of a large number of instruments utilized for the clinical assessment of COPD in the same subjects over the same period. We utilized SPIROMICS participants (n = 98) that returned to their clinical center within 6 weeks of their baseline visit to repeat complete baseline assessments. Demographics, spirometry, questionnaires, complete blood cell counts (CBC), medical history, and emphysema status by computerized tomography (CT) imaging were obtained. Results Pulmonary function tests (PFTs) were highly repeatable (ICC’s >0.9) but the 6 minute walk (6MW) was less so (ICC = 0.79). Among questionnaires, the Saint George’s Respiratory Questionnaire (SGRQ) was most repeatable. Self-reported clinical features, such as exacerbation history, and features of chronic bronchitis, often produced kappa values <0.6. Reported age at starting smoking and average number of cigarettes smoked were modestly repeatable (kappa = 0.76 and 0.79). Complete blood counts (CBC) variables produced intraclass correlation coefficients (ICC) values between 0.6 and 0.8. Conclusions PFTs were highly repeatable, while subjective measures and subject recall were more variable. Analyses using features with poor repeatability could lead to misclassification and outcome errors. Hence, care should be taken when interpreting change in clinical features based on measures with low repeatability. Efforts to improve repeatability of key clinical features such as exacerbation history and chronic bronchitis are warranted. PMID:28934249
Al-Amri, Mohammad; Al Balushi, Hilal; Mashabi, Abdulrhman
2017-12-01
Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system. Twenty-three male able-bodied adults (age: 34.56 ± 5.12 years) completed two separate gait assessments on the GRAIL system, separated by 5 ± 3 days. Key gait kinematic, kinetic, and spatial-temporal parameters were analysed. The Intraclass-Correlation Coefficients (ICC), Standard Error Measurement (SEM), Minimum Detectable Change (MDC), and the 95% limits of agreements were calculated to evaluate the repeatability of these gait parameters. Day-to-day agreements were excellent (ICCs > 0.87) for spatial-temporal parameters with low MDC and SEM values, <0.153 and <0.055, respectively. The repeatability was higher for joint kinetic than kinematic parameters, as reflected in small values of SEM (<0.13 Nm/kg and <3.4°) and MDC (<0.335 Nm/kg and <9.44°). The obtained values of all parameters fell within the 95% limits of agreement. Our findings demonstrate the repeatability of the GRAIL system available in our laboratory. The SEM and MDC values can be used to assist researchers and clinicians to distinguish 'real' changes in gait performance over time.
Conservation of human chromosome 13 polymorphic microsatellite (CA){sub n} repeats in chimpanzees
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deka, R.; Shriver, M.D.; Yu, L.M.
Tandemly repeated (dC-dA){sub n} {center_dot} (dG-dT){sub n} sequences occur abundantly and are found in most eukaryotic genomes. To investigate the level of conservation of these repeat sequences in nonhuman primates, the authors have analyzed seven human chromosome 13 dinucleotide (CA){sub n} repeat loci in chimpanzees by DNA amplification using primers designed for analysis of human loci. Comparable levels of polymorphism at these loci in the two species, revealed by the number of alleles, heterozygosity, and allele sizes, suggest that the (CA){sub n} repeat arrays and their genomic locations are highly conserved. Even though the proportion of shared alleles between themore » two species varies enormously and the modal alleles are not the same, allelic lengths at each locus in the chimpanzees are detected within the bounds of the allele size range observed in humans. A similar observation has been noted in a limited number of gorillas and orangutans. Using a new measure of genetic distance that takes into account the size of alleles, they have compared the genetic distance between humans and chimpanzees. The genetic distance between these two species was found to be ninefold smaller than expected assuming there is no selection or mutational bias toward retention of (CA){sub n} repeat arrays. These findings suggest a functional significance for these microsatellite loci. 34 refs., 1 fig., 2 tabs.« less
Clayton, William; Eaton, Carla Jane; Dupont, Pierre-Yves; Gillanders, Tim; Cameron, Nick; Saikia, Sanjay; Scott, Barry
2017-01-01
Epichloë grass endophytes comprise a group of filamentous fungi of both sexual and asexual species. Known for the beneficial characteristics they endow upon their grass hosts, the identification of these endophyte species has been of great interest agronomically and scientifically. The use of simple sequence repeat loci and the variation in repeat elements has been used to rapidly identify endophyte species and strains, however, little is known of how the structure of repeat elements changes between species and strains, and where these repeat elements are located in the fungal genome. We report on an in-depth analysis of the structure and genomic location of the simple sequence repeat locus B10, commonly used for Epichloë endophyte species identification. The B10 repeat was found to be located within an exon of a putative bZIP transcription factor, suggesting possible impacts on polypeptide sequence and thus protein function. Analysis of this repeat in the asexual endophyte hybrid Epichloë uncinata revealed that the structure of B10 alleles reflects the ancestral species that hybridized to give rise to this species. Understanding the structure and sequence of these simple sequence repeats provides a useful set of tools for readily distinguishing strains and for gaining insights into the ancestral species that have undergone hybridization events.
Hoffmann, K; Kesners, P; Bader, A; Avermaete, A; Altmeyer, P; Gambichler, T
2001-11-01
Spectrophotometric assessment (in vitro) is the most established method for determining the ultraviolet protection factor (UPF) of textiles. Apart from stringent requirements for measurement precision, practical methods are required for the routine determination of the UPF. We report here spectrophotometric measurements of textiles using a newly developed autosampler. Measurement precision was evaluated under repeatable conditions. Fifteen different textiles were spectrophotometrically assessed for the determination of the UPF. Sample handling inside the spectrophotometer was performed with a computer-controlled sampling device, capable of loading and unloading a textile sample from a magazine as well as rotating the sample perpendicular to the spectrometer beam. In order to evaluate the repeatability of measurements, one sample of each textile was assessed eight times under the same conditions in the same laboratory. A mean percentage of the standard error of 1% [E(UPF)] was calculated for the UPF measurements. For UPFs >30, a significantly higher E(UPF) was found (r=0.78; P<0.001). E(UV) (3.9%) of ultraviolet A (UVA) transmission differed significantly from E(UV) (1.1 %) of ultraviolet B (UVB) transmission (P<0.05). Though a slight decrease of repeatability was observed for UVA transmission measurements and UPFs higher than 30, our data indicate a high measurement precision under repeatable conditions. In conclusion, spectrophotometric measurements of textiles with the aid of the autosampler presented have been shown to be highly practical, time saving and precise.
Validation of a 3D CT method for measurement of linear wear of acetabular cups
2011-01-01
Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17°. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy. PMID:21281259
Effect Sizes and their Intervals: The Two-Level Repeated Measures Case
ERIC Educational Resources Information Center
Algina, James; Keselman, H. J.; Penfield, Randall D.
2005-01-01
Probability coverage for eight different confidence intervals (CIs) of measures of effect size (ES) in a two-level repeated measures design was investigated. The CIs and measures of ES differed with regard to whether they used least squares or robust estimates of central tendency and variability, whether the end critical points of the interval…
Baines, Anthony J
2003-01-01
The spectrin superfamily (spectrin, alpha-actinin, utrophin and dystrophin) has in common a triple helical repeating unit of ~106 amino acid residues. In spectrin, alpha and beta chains contain multiple copies of this repeat. beta-spectrin chains contain the majority of binding activities in spectrin and are essential for animal life. Canonical beta-spectrins have 17 repeats; beta-heavy spectrins have 30. Here, the repeats of five human beta-spectrins, plus beta-spectrins from several other vertebrates and invertebrates, have been analysed. Repeats 1, 2, 14 and 17 in canonical beta are highly conserved between invertebrates and vertebrates, and repeat 8 in some isoforms. This is consistent with conservation of critical functions, since repeats 1, 2 and 17 bind alpha-spectrin. Repeats 1 of beta-spectrins are not always detected by SMART or Pfam tools. A profile hidden Markov model of beta-spectrin repeat 1 detects alpha-actinins, but not utrophin or dystrophin. Novel examples of repeat 1 were detected in the spectraplakins MACF1, BPAG1 and plectin close to the actin-binding domain. Ankyrin binds to the C-terminal portion of repeat 14; the high conservation of this entire repeat may point to additional, undiscovered ligand-binding activities. This analysis indicates that the basic triple helical repeat pattern was adapted early in the evolution of the spectrin superfamily to encompass essential binding activities, which characterise individual repeats in proteins extant today.
2010-06-28
Variance (ANOVA) Table for Serum Corticosterone Table 15 – Repeated-Measures ANOVA Table for Body Weight, Within-Subject Effects Table 16...Serum Ethanol Concentration Table 21 – Repeated-Measures ANOVA Table for Rotarod Performance, Within- Subject Effects Table 22 – Repeated...and that this social environment seems to attenuate the effects of predator and unpredictable stressors on serum corticosterone . In summary, stressed
Incremental Dynamic Analysis of Koyna Dam under Repeated Ground Motions
NASA Astrophysics Data System (ADS)
Zainab Nik Azizan, Nik; Majid, Taksiah A.; Nazri, Fadzli Mohamed; Maity, Damodar; Abdullah, Junaidah
2018-03-01
This paper discovers the incremental dynamic analysis (IDA) of concrete gravity dam under single and repeated earthquake loadings to identify the limit state of the dam. Seven ground motions with horizontal and vertical direction as seismic input considered in the nonlinear dynamic analysis based on the real repeated earthquake in the worldwide. All the ground motions convert to respond spectrum and scaled according to the developed elastic respond spectrum in order to match the characteristic of the ground motion to the soil type. The scaled was depends on the fundamental period, T1 of the dam. The Koyna dam has been selected as a case study for the purpose of the analysis by assuming that no sliding and rigid foundation, has been estimated. IDA curves for Koyna dam developed for single and repeated ground motions and the performance level of the dam identifies. The IDA curve of repeated ground motion shown stiffer rather than single ground motion. The ultimate state displacement for a single event is 45.59mm and decreased to 39.33mm under repeated events which are decreased about 14%. This showed that the performance level of the dam based on seismic loadings depend on ground motion pattern.
Finding Clothing That Fit through Cluster Analysis and Objective Interestingness Measures
NASA Astrophysics Data System (ADS)
Peña, Isis; Viktor, Herna L.; Paquet, Eric
Clothes should fit consumers well, be aesthetically pleasing and comfortable. However, repeated studies of customers’ levels of satisfaction indicate that this is often not the case. For example, more robust males often find it difficult to find pants that are the correct length and fit their waists well. What, then, are the typical body profiles of the population? Would it be possible to identify the measurements that are of importance for different sizes and genders? Furthermore, assuming that we have access to an anthropometric database would there be a way to guide the data mining process to discover only those relevant body measurements that are of the most interest for apparel designers? This paper describes our results when addressing these questions through cluster analysis and interestingness measures-based feature selection. We explore a database containing anthropometric measurements as well as 3-D body scans, of a representative sample of the Dutch population.
Evaluation of accuracy, reliability, and repeatability of five dental pulp tests.
Chen, Eugene; Abbott, Paul V
2011-12-01
The aim of this study was to compare the clinical accuracy, reliability, and repeatability of laser Doppler flowmetry (LDF), an electric pulp test (EPT), and various thermal pulp sensibility tests. Pulp tests were done on 121 teeth in 20 subjects by using LDF, EPT, and thermal pulp testing (CO(2), Endo Frost [EF], Ice) during 2 or 3 test sessions with at least 1-week intervals. The order of testing was reversed on the second visit. A laser Doppler flowmeter was used to measure mean pulp blood flow (Flux) calibrated against a brownian motion medium and zeroed against a static reflector. The laser source was 780 nm, with 0.5-mm fiber separation in the probe, 3.1 kHz as the primary bandwidth for filter set to 0.1-second time output constant. Customized polyvinylsiloxane splints were fabricated for each participant, and a minimum of 90-second recording time was used for each tooth. Raw data were analyzed by using repeated measure analysis of variance, pairwise comparisons, and interclass correlations (ICC). The accuracy of EPT, CO(2), and LDF tests was 97.7%, 97.0%, and 96.3%, respectively, without significant differences (P > .3). Accuracy of EF and Ice was 90.7% and 84.8%, respectively. EPT (P = .015) and CO(2) (P = .022) were significantly more accurate than EF. LDF was more accurate than EF, but this was not statistically significant (P = .063). Ice was significantly less accurate than EPT (P = .004), CO(2) (P = .005), LDF (P = .006), and EF (P = .019). With the exception of Ice (effect of visit: F(2,38) = 5.67, mean squared error = 0.01, P = .007, η(2)(p) = 0.23), all tests were reliable. Ice (ICC = 0.677) and LDF (ICC = 0.654) were the most repeatable of the tests, whereas EPT (ICC = 0.434) and CO(2) (ICC = 0.432) were less repeatable. CO(2), EPT, and LDF were reliable and the most accurate tests, but CO(2) and EPT were less repeatable yet less time-consuming than LDF. EF was reliable but not as accurate as EPT and CO(2) and less repeatable than Ice and LDF. Ice was the most repeatable but the least accurate and least reliable test. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Price, Katie; Ballow, William
2015-04-01
Traditional high-precision survey methods for stream channel measurement are labor-intensive and require wadeability or boat access to streams. These conditions limit the number of sites researchers are able to study and generally prohibit the possibility of repeat channel surveys to evaluate short-term fluctuations in channel morphology. In recent years, unmanned aerial vehicles (drones) equipped with photo and video capabilities have become widely available and affordable. Concurrently, developments in photogrammetric software offer unprecedented mapping and 3D rendering capabilities of drone-captured photography. In this study, we evaluate the potential use of drone-mounted cameras for detailed stream channel morphometric analysis. We used a relatively low-cost drone (DJI Phantom 2+ Vision) and commercially available, user friendly software (Agisoft Photscan) for photogrammetric analysis of drone-captured stream channel photography. Our test study was conducted on Proctor Creek, a highly responsive urban stream in Atlanta, Georgia, within the crystalline Piedmont region of the southeastern United States. As a baseline, we performed traditional high-precision survey methods to collect morphological measurements (e.g., bankfull and wetted width, bankfull and wetted thalweg depth) at 11 evenly-spaced transects, following USGS protocols along reaches of 20 times average channel width. We additionally used the drone to capture 200+ photos along the same reaches, concurrent with the channel survey. Using the photogrammetry software, we generated georeferenced 3D models of the stream channel, from which morphological measurements were derived from the 11 transects and compared with measurements from the traditional survey method. We additionally explored possibilities for novel morphometric characterization available from the continuous 3D surface, as an improvement on the limited number of detailed cross-sections available from standard methods. These results showed great promise for the drone photogrammetry methods, which encouraged the exploration of the possibility of repeat aerial surveys to evaluate channel response to high flow events. Repeat drone surveys were performed following a sequence of high-flow events in Proctor Creek to evaluate the possibility of using these methods for assessment of stream channel response to flooding.
Using one-dimensional waveguide resonators to measure phase velocities in bubbly liquids.
Dolder, Craig N; Wilson, Preston S
2017-04-01
Resonator techniques can be successfully used to extract effective medium properties from dispersive materials. However, in some cases the dispersion can cause modes to repeat. If repeated modes are not taken into account, the useful range of the resonator technique is limited. A resonance tube containing tethered balloons is used to create a dispersive effective medium. Resonator measurements show that modes do repeat. Direct measurement of the mode shapes allows exploitation of all longitudinal radially symmetric modes and expands the frequency range of the technique. A theoretical model is also used to predict when modes repeat. For the presented data set this method increases the measurement range from below 160 Hz to 3000 Hz excluding the stop band where resonances are damped. A means to account for non-ideal resonator boundary conditions often found in highly dispersive systems is discussed.
In-vivo assessment of total body protein in rats by prompt-γ neutron activation analysis
NASA Astrophysics Data System (ADS)
Stamatelatos, Ion E.; Boozer, Carol N.; Ma, Ruimei; Yasumura, Seiichi
1997-02-01
A prompt-(gamma) neutron activation analysis facility for in vivo determination of total body protein (TBP) in rats has been designed. TBP is determined in vivo by assessment of total body nitrogen. The facility is based on a 252Cf radionuclide neutron source within a heavy water moderator assembly and two NaI(Tl) scintillation detectors. The in vivo precision of the technique, as estimated by three repeated measurements of 15 rats is 6 percent, for a radiation dose equivalent of 60 mSv. The radiation dose per measurement is sufficiently low to enable serial measurements on the same animal. MCNP-4A Monte Carlo transport code was utilized to calculate thermal neutron flux correction factors to account for differences in size and shape of the rats and calibration phantoms. Good agrement was observed in comparing body nitrogen assessment by prompt-(gamma) neutron activation and chemical carcass analysis.
Li, Zhi; Gothard, Elizabeth; Coles, Mark C; Ambler, Carrie A
2018-01-01
In skin wounds, innate-immune cells clear up tissue debris and microbial contamination, and also secrete cytokines and other growth factors that impact repair process such as re-epithelialization and wound closure. After injury, there is a rapid influx and efflux of immune cells at wound sites, yet the function of each innate cell population in skin repair is still under investigation. Flow cytometry is a valuable research tool for detecting and quantifying immune cells; however, in mouse back skin, the difficulty in extracting immune cells from small area of skin due to tissue complexity has made cytometric analysis an underutilized tool. In this paper, we provide detailed methods on the digestion of lesion-specific skin without disrupting antigen expression followed by multiplex cell staining that allows for identification of seven innate-immune populations, including rare subsets such as group-3 innate lymphoid cells (ILC3s), by flow-cytometry analysis. Furthermore, when studying the functions of immune cells to tissue repair an important metric to monitor is size of the wound opening. Normal wounds close steadily albeit at non-linear rates, while slow or stalled wound closure can indicate an underlying problem with the repair process. Calliper measurements are difficult and time-consuming to obtain and can require repeated sedation of experimental animals. We provide advanced methods for measuring of wound openness; digital 3D image capture and semi-automated image processing that allows for unbiased, reliable measurements that can be taken repeatedly over time.
Li, Zhi; Gothard, Elizabeth; Coles, Mark C.; Ambler, Carrie A.
2018-01-01
In skin wounds, innate-immune cells clear up tissue debris and microbial contamination, and also secrete cytokines and other growth factors that impact repair process such as re-epithelialization and wound closure. After injury, there is a rapid influx and efflux of immune cells at wound sites, yet the function of each innate cell population in skin repair is still under investigation. Flow cytometry is a valuable research tool for detecting and quantifying immune cells; however, in mouse back skin, the difficulty in extracting immune cells from small area of skin due to tissue complexity has made cytometric analysis an underutilized tool. In this paper, we provide detailed methods on the digestion of lesion-specific skin without disrupting antigen expression followed by multiplex cell staining that allows for identification of seven innate-immune populations, including rare subsets such as group-3 innate lymphoid cells (ILC3s), by flow-cytometry analysis. Furthermore, when studying the functions of immune cells to tissue repair an important metric to monitor is size of the wound opening. Normal wounds close steadily albeit at non-linear rates, while slow or stalled wound closure can indicate an underlying problem with the repair process. Calliper measurements are difficult and time-consuming to obtain and can require repeated sedation of experimental animals. We provide advanced methods for measuring of wound openness; digital 3D image capture and semi-automated image processing that allows for unbiased, reliable measurements that can be taken repeatedly over time. PMID:29535723
Sinclair, Jonathan K; Vincent, Hayley; Richards, Jim D
2017-01-01
To investigate the effects of a prophylactic knee brace on knee joint kinetics and kinematics during netball specific movements. Repeated measures. Laboratory. Twenty university first team level female netball players. Participants performed three movements, run, cut and vertical jump under two conditions (brace and no-brace). 3-D knee joint kinetics and kinematics were measured using an eight-camera motion analysis system. Knee joint kinetics and kinematics were examined using 2 × 3 repeated measures ANOVA whilst the subjective ratings of comfort and stability were investigated using chi-squared tests. The results showed no differences (p > 0.05) in knee joint kinetics. However the internal/external rotation range of motion was significantly (p < 0.05) reduced when wearing the brace in all movements. The subjective ratings of stability revealed that netballers felt that the knee brace improved knee stability in all movements. Further study is required to determine whether reductions in transverse plane knee range of motion serve to attenuate the risk from injury in netballers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sheppard, James P.; Holder, Roger; Nichols, Linda; Bray, Emma; Hobbs, F.D. Richard; Mant, Jonathan; Little, Paul; Williams, Bryan; Greenfield, Sheila; McManus, Richard J.
2014-01-01
Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35–84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice. PMID:25144295
Bodaghabadi, Mohammad; Riazi, Hooman; Aran, Shima; Bitaraf, Mohammad Ali; Alikhani, Mazdak; Alahverdi, Mahmud; Mohamadi, Masoumeh; Shalileh, Keivan; Azar, Maziar
2014-03-01
This study compared Gamma knife radiosurgery (GKRS) and repeated transsphenoidal adenomectomy (TSA) to find the best approach for recurrence of Cushing disease (CD) after unsuccessful first TSA. Fifty-two patients with relapse of CD after TSA were enrolled and randomly underwent a second surgery or GKRS as the next therapeutic approach. They were followed for a mean period of 3.05 ± 0.8 years by physical examination and hormone measurement as well as magnetic resonance imaging. No significant difference was observed in sex ratio, mean age, adenoma type, follow-up duration, and initial hormone level between the two groups. No significant relationship was found between preoperative 24-hour free urine cortisol and disease-free months or tumor volume among both groups. Our statistical analysis showed higher recurrence-free interval in the GKRS group compared with TSA group. With longer recurrence-free interval, GKRS could be considered a good treatment alternative to repeated TSA in recurrent CD. Georg Thieme Verlag KG Stuttgart · New York.
Repeated Measurement of the Intermountain Risk Score Enhances Prognostication for Mortality
Horne, Benjamin D.; Lappé, Donald L.; Muhlestein, Joseph B.; May, Heidi T.; Ronnow, Brianna S.; Brunisholz, Kimberly D.; Kfoury, Abdallah G.; Bunch, T. Jared; Alharethi, Rami; Budge, Deborah; Whisenant, Brian K.; Bair, Tami L.; Jensen, Kurt R.; Anderson, Jeffrey L.
2013-01-01
Background The Intermountain Risk Score (IMRS), composed of the complete blood count (CBC) and basic metabolic profile (BMP), predicts mortality and morbidity in medical and general populations. Whether longitudinal repeated measurement of IMRS is useful for prognostication is an important question for its clinical applicability. Methods Females (N = 5,698) and males (N = 5,437) with CBC and BMP panels measured 6 months to 2.0 years apart (mean 1.0 year) had baseline and follow-up IMRS computed. Survival analysis during 4.0±2.5 years (maximum 10 years) evaluated mortality (females: n = 1,255 deaths; males: n = 1,164 deaths) and incident major events (myocardial infarction, heart failure [HF], and stroke). Results Both baseline and follow-up IMRS (categorized as high-risk vs. low-risk) were independently associated with mortality (all p<0.001) in bivariable models. For females, follow-up IMRS had hazard ratio (HR) = 5.23 (95% confidence interval [CI] = 4.11, 6.64) and baseline IMRS had HR = 3.66 (CI = 2.94, 4.55). Among males, follow-up IMRS had HR = 4.28 (CI = 3.51, 5.22) and baseline IMRS had HR = 2.32 (CI = 1.91, 2.82). IMRS components such as RDW, measured at both time points, also predicted mortality. Baseline and follow-up IMRS strongly predicted incident HF in both genders. Conclusions Repeated measurement of IMRS at baseline and at about one year of follow-up were independently prognostic for mortality and incident HF among initially hospitalized patients. RDW and other CBC and BMP values were also predictive of outcomes. Further research should evaluate the utility of IMRS as a tool for clinical risk adjustment. PMID:23874899
Optimized two-frequency phase-measuring-profilometry light-sensor temporal-noise sensitivity.
Li, Jielin; Hassebrook, Laurence G; Guan, Chun
2003-01-01
Temporal frame-to-frame noise in multipattern structured light projection can significantly corrupt depth measurement repeatability. We present a rigorous stochastic analysis of phase-measuring-profilometry temporal noise as a function of the pattern parameters and the reconstruction coefficients. The analysis is used to optimize the two-frequency phase measurement technique. In phase-measuring profilometry, a sequence of phase-shifted sine-wave patterns is projected onto a surface. In two-frequency phase measurement, two sets of pattern sequences are used. The first, low-frequency set establishes a nonambiguous depth estimate, and the second, high-frequency set is unwrapped, based on the low-frequency estimate, to obtain an accurate depth estimate. If the second frequency is too low, then depth error is caused directly by temporal noise in the phase measurement. If the second frequency is too high, temporal noise triggers ambiguous unwrapping, resulting in depth measurement error. We present a solution for finding the second frequency, where intensity noise variance is at its minimum.
Stewart, Sarah; Pearson, Janet; Rome, Keith; Dalbeth, Nicola; Vandal, Alain C
2018-01-01
Statistical techniques currently used in musculoskeletal research often inefficiently account for paired-limb measurements or the relationship between measurements taken from multiple regions within limbs. This study compared three commonly used analysis methods with a mixed-models approach that appropriately accounted for the association between limbs, regions, and trials and that utilised all information available from repeated trials. Four analysis were applied to an existing data set containing plantar pressure data, which was collected for seven masked regions on right and left feet, over three trials, across three participant groups. Methods 1-3 averaged data over trials and analysed right foot data (Method 1), data from a randomly selected foot (Method 2), and averaged right and left foot data (Method 3). Method 4 used all available data in a mixed-effects regression that accounted for repeated measures taken for each foot, foot region and trial. Confidence interval widths for the mean differences between groups for each foot region were used as a criterion for comparison of statistical efficiency. Mean differences in pressure between groups were similar across methods for each foot region, while the confidence interval widths were consistently smaller for Method 4. Method 4 also revealed significant between-group differences that were not detected by Methods 1-3. A mixed effects linear model approach generates improved efficiency and power by producing more precise estimates compared to alternative approaches that discard information in the process of accounting for paired-limb measurements. This approach is recommended in generating more clinically sound and statistically efficient research outputs. Copyright © 2017 Elsevier B.V. All rights reserved.
Guest, Rebecca; Craig, Ashley; Nicholson Perry, Kathryn; Tran, Yvonne; Ephraums, Catherine; Hales, Alison; Dezarnaulds, Annalisa; Crino, Rocco; Middleton, James
2015-11-01
To examine change in resilience in people with spinal cord injury (SCI) when group cognitive behavior therapy (GCBT) was added to routine psychosocial rehabilitation (RPR). A prospective repeated-measures cohort design was used to determine the efficacy of the addition of GCBT (n = 50). The control group consisted of individuals receiving RPR, which included access to individual CBT (ICBT) when required (n = 38). Groups were assessed on 3 occasions: soon after admission, within 2 weeks of discharge, and 6-months postdischarge. Measures included sociodemographic, injury, and psychosocial factors. The outcome variable was resilience, considered an important outcome measure for recovery. To adjust for baseline differences in self-efficacy, depressive mood and anxiety between the 2 groups, these factors were entered into a repeated measures multivariate analysis of covariance (MANCOVA) as covariates. Latent class analysis was used to determine the best-fitting model of resilience trajectories for both groups. The MANCOVA indicated that the addition of GCBT to psychosocial rehabilitation did not result in improved resilience compared with the ICBT group. Trajectory data indicated over 60% were demonstrating acceptable resilience irrespective of group. Changes in resilience mean scores suggest the addition of GCBT adds little to resilience outcomes. Latent class modeling indicated both groups experienced similar trajectories of improvement and deterioration. Results highlight the importance of conducting multivariate modeling analysis that isolates subgroups of related cases over time to understand complex trajectories. Further research is needed to clarify individual differences in CBT intervention preference as well as other factors which impact on resilience. (c) 2015 APA, all rights reserved).
Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes
Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske
2014-01-01
Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580
Al-Farhan, Haya M; Al-Otaibi, Wafa’a Majed
2012-01-01
Purpose To compare the precision of central corneal thickness (CCT) measurements taken with the handheld ultrasound pachymeter (USP), ultrasound biomicroscopy (UBM), and the Artemis-2 very high frequency ultrasound scanner (VHFUS) on normal subjects. Design Prospective study. Methods One eye from each of 61 normal subjects was randomly selected for this study. The measurements of the CCT were taken with the USP, VHFUS, and UBM. Results were compared statistically using repeated-measures analysis of variance (ANOVA), Pearson’s correlation coefficient, and limits of agreement. Results The average CCT (± standard deviation) was 530.1 ± 30.5 μm, 554.9 ± 31.7 μm, and 559.5 ± 30.7 μm for UBM, VHFUS, and USP respectively. The intraobserver repeatability analyses of variance are not significant for USP, UBM, and VHFUS. P-values were 0.17, 0.19, and 0.37 respectively. Repeated-measures ANOVA showed a significant difference between the three different methods of measuring CCT (P = 0.0001). The ANOVA test revealed no statistically significant difference between USP and VHFUS (P > 0.05), yet statistical significant differences with UBM versus USP and UBM versus VHFUS (P < 0.001). There were high correlations between the three instruments (P < 0.0001). The mean differences (and upper/lower limits of agreement) for CCT measurements were 29.4 ± 14.3 (2.7/56), 4.6 ± 8.6 (−14.7/23.8), and −24.8 ± 13.1 (−50.4/0.8) for USP versus UBM, USP versus VHFUS, and UBM versus VHFUS, respectively. Conclusion The UBM produces CCT measurements that vary significantly from those returned by the USP and the VHFUS, suggesting that the UBM may not be used interchangeably with either equipment for monitoring the CCT in the clinical setting. PMID:22848145
Prata, Diana P; Mechelli, Andrea; Picchioni, Marco M; Fu, Cynthia H Y; Toulopoulou, Timothea; Bramon, Elvira; Walshe, Muriel; Murray, Robin M; Collier, David A; McGuire, Philip
2009-11-01
The dopamine transporter plays a key role in the regulation of central dopaminergic transmission, which modulates cognitive processing. Disrupted dopamine function and impaired executive processing are robust features of schizophrenia. To examine the effect of a polymorphism in the dopamine transporter gene (the variable number of tandem repeats in the 3' untranslated region) on brain function during executive processing in healthy volunteers and patients with schizophrenia. We hypothesized that this variation would have a different effect on prefrontal and striatal activation in schizophrenia, reflecting altered dopamine function. Case-control study. Psychiatric research center. Eighty-five subjects, comprising 44 healthy volunteers (18 who were 9-repeat carriers and 26 who were 10-repeat homozygotes) and 41 patients with DSM-IV schizophrenia (18 who were 9-repeat carriers and 23 who were 10-repeat homozygotes). Regional brain activation during word generation relative to repetition in an overt verbal fluency task measured by functional magnetic resonance imaging. Main effects of genotype and diagnosis on activation and their interaction were estimated with analysis of variance in SPM5. Irrespective of diagnosis, the 10-repeat allele was associated with greater activation than the 9-repeat allele in the left anterior insula and right caudate nucleus. Trends for the same effect in the right insula and for greater deactivation in the rostral anterior cingulate cortex were also detected. There were diagnosis x genotype interactions in the left middle frontal gyrus and left nucleus accumbens, where the 9-repeat allele was associated with greater activation than the 10-repeat allele in patients but not controls. Insular, cingulate, and striatal function during an executive task is normally modulated by variation in the dopamine transporter gene. Its effect on activation in the dorsolateral prefrontal cortex and ventral striatum is altered in patients with schizophrenia. This may reflect altered dopamine function in these regions in schizophrenia.
Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won
2017-01-01
To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.
Koreňová, Janka; Rešková, Zuzana; Véghová, Adriana; Kuchta, Tomáš
2015-01-01
Contamination by Staphylococcus aureus of the production environment of three small or medium-sized food-processing factories in Slovakia was investigated on the basis of sub-species molecular identification by multiple locus variable number of tandem repeats analysis (MLVA). On the basis of MLVA profiling, bacterial isolates were assigned to 31 groups. Data from repeated samplings over a period of 3 years facilitated to draw spatial and temporal maps of the contamination routes for individual factories, as well as identification of potential persistent strains. Information obtained by MLVA typing allowed to identify sources and routes of contamination and, subsequently, will allow to optimize the technical and sanitation measures to ensure hygiene.
Interpreting null results from measurements with uncertain correlations: an info-gap approach.
Ben-Haim, Yakov
2011-01-01
Null events—not detecting a pernicious agent—are the basis for declaring the agent is absent. Repeated nulls strengthen confidence in the declaration. However, correlations between observations are difficult to assess in many situations and introduce uncertainty in interpreting repeated nulls. We quantify uncertain correlations using an info-gap model, which is an unbounded family of nested sets of possible probabilities. An info-gap model is nonprobabilistic and entails no assumption about a worst case. We then evaluate the robustness, to uncertain correlations, of estimates of the probability of a null event. This is then the basis for evaluating a nonprobabilistic robustness-based confidence interval for the probability of a null. © 2010 Society for Risk Analysis.
Regression Models for the Analysis of Longitudinal Gaussian Data from Multiple Sources
O’Brien, Liam M.; Fitzmaurice, Garrett M.
2006-01-01
We present a regression model for the joint analysis of longitudinal multiple source Gaussian data. Longitudinal multiple source data arise when repeated measurements are taken from two or more sources, and each source provides a measure of the same underlying variable and on the same scale. This type of data generally produces a relatively large number of observations per subject; thus estimation of an unstructured covariance matrix often may not be possible. We consider two methods by which parsimonious models for the covariance can be obtained for longitudinal multiple source data. The methods are illustrated with an example of multiple informant data arising from a longitudinal interventional trial in psychiatry. PMID:15726666
Analytical and Photogrammetric Characterization of a Planar Tetrahedral Truss
NASA Technical Reports Server (NTRS)
Wu, K. Chauncey; Adams, Richard R.; Rhodes, Marvin D.
1990-01-01
Future space science missions are likely to require near-optical quality reflectors which are supported by a stiff truss structure. This support truss should conform closely with its intended shape to minimize its contribution to the overall surface error of the reflector. The current investigation was conducted to evaluate the planar surface accuracy of a regular tetrahedral truss structure by comparing the results of predicted and measured node locations. The truss is a 2-ring hexagonal structure composed of 102 equal-length truss members. Each truss member is nominally 2 meters in length between node centers and is comprised of a graphite/epoxy tube with aluminum nodes and joints. The axial stiffness and the length variation of the truss components were determined experimentally and incorporated into a static finite element analysis of the truss. From this analysis, the root mean square (RMS) surface error of the truss was predicted to be 0.11 mm (0004 in). Photogrammetry tests were performed on the assembled truss to measure the normal displacements of the upper surface nodes and to determine if the truss would maintain its intended shape when subjected to repeated assembly. Considering the variation in the truss component lengths, the measures rms error of 0.14 mm (0.006 in) in the assembled truss is relatively small. The test results also indicate that a repeatable truss surface is achievable. Several potential sources of error were identified and discussed.
Mostafa, Ayman A; Cunningham, Devin P; Boudrieau, Randy J; Kowaleski, Michael P; Griffon, Dominique J
2018-04-01
To determine repeatability of and correlation between 2 radiographic measurements of femoral anteversion angles (FAA) and to determine their influence on a score derived from tibial plateau angle (TPA) and FAA to predict the risk of cranial cruciate ligament disease (CCLD). Prospective clinical study. Forty-eight Labrador retrievers with or without CCLD. FAA and CCLD scores were calculated for each limb from extended pelvic radiographs (t-FAA) or angled (a-FAA) projections of the femur by 3 investigators. One investigator repeated measurements twice. Data were analyzed for repeatability, correlation between t-FAA and a-FAA, and their influence on CCLD scores. FAA correlated most strongly with the distance between the femoral head and the femoral axis on mediolateral radiographs, a measurement with excellent repeatability. t-FAA and a-FAA correlated with each other (r > 0.79, P < .0001), although t-FAA were about 1° greater than a-FAA (P = .01). Intrainvestigator and interinvestigator repeatability of the CCLD score was fair when derived from t-FAA and good to excellent when derived from a-FAA. CCLD scores differed between radiographic techniques but led to different predictions in only 9 (10%) limbs, all with lower TPA and CCLD scores than the rest of the population. a-FAA correlated strongly with t-FAA and improved the repeatability of CCLD scores within and between investigators. A craniocaudal angled beam projection of the femur is a suitable alternative to a ventrodorsal pelvic radiograph when measuring FAA and may improve the repeatability and positive predictive value of CCLD scores. © 2018 The American College of Veterinary Surgeons.
The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery
Dorotta, Ihab L.; Wells, Briana; Juma, David; Applegate, Patricia M.
2016-01-01
BACKGROUND: The use of intraoperative pulse oximetry (Spo2) enhances hypoxia detection and is associated with fewer perioperative hypoxic events. However, Spo2 may be reported as 98% when arterial partial pressure of oxygen (Pao2) is as low as 70 mm Hg. Therefore, Spo2 may not provide advance warning of falling arterial oxygenation until Pao2 approaches this level. Multiwave pulse co-oximetry can provide a calculated oxygen reserve index (ORI) that may add to information from pulse oximetry when Spo2 is >98%. This study evaluates the ORI to Pao2 relationship during surgery. METHODS: We studied patients undergoing scheduled surgery in which arterial catheterization and intraoperative arterial blood gas analysis were planned. Data from multiple pulse co-oximetry sensors on each patient were continuously collected and stored on a research computer. Regression analysis was used to compare ORI with Pao2 obtained from each arterial blood gas measurement and changes in ORI with changes in Pao2 from sequential measurements. Linear mixed-effects regression models for repeated measures were then used to account for within-subject correlation across the repeatedly measured Pao2 and ORI and for the unequal time intervals of Pao2 determination over elapsed surgical time. Regression plots were inspected for ORI values corresponding to Pao2 of 100 and 150 mm Hg. ORI and Pao2 were compared using mixed-effects models with a subject-specific random intercept. RESULTS: ORI values and Pao2 measurements were obtained from intraoperative data collected from 106 patients. Regression analysis showed that the ORI to Pao2 relationship was stronger for Pao2 to 240 mm Hg (r2 = 0.536) than for Pao2 over 240 mm Hg (r2 = 0.0016). Measured Pao2 was ≥100 mm Hg for all ORI over 0.24. Measured Pao2 was ≥150 mm Hg in 96.6% of samples when ORI was over 0.55. A random intercept variance component linear mixed-effects model for repeated measures indicated that Pao2 was significantly related to ORI (β[95% confidence interval] = 0.002 [0.0019–0.0022]; P < 0.0001). A similar analysis indicated a significant relationship between change in Pao2 and change in ORI (β [95% confidence interval] = 0.0044 [0.0040–0.0048]; P < 0.0001). CONCLUSIONS: These findings suggest that ORI >0.24 can distinguish Pao2 ≥100 mm Hg when Spo2 is over 98%. Similarly, ORI > 0.55 appears to be a threshold to distinguish Pao2 ≥150 mm Hg. The usefulness of these values should be evaluated prospectively. Decreases in ORI to near 0.24 may provide advance indication of falling Pao2 approaching 100 mm Hg when Spo2 is >98%. The clinical utility of interventions based on continuous ORI monitoring should be studied prospectively. PMID:27007078
Applegate, Richard L; Dorotta, Ihab L; Wells, Briana; Juma, David; Applegate, Patricia M
2016-09-01
The use of intraoperative pulse oximetry (SpO2) enhances hypoxia detection and is associated with fewer perioperative hypoxic events. However, SpO2 may be reported as 98% when arterial partial pressure of oxygen (PaO2) is as low as 70 mm Hg. Therefore, SpO2 may not provide advance warning of falling arterial oxygenation until PaO2 approaches this level. Multiwave pulse co-oximetry can provide a calculated oxygen reserve index (ORI) that may add to information from pulse oximetry when SpO2 is >98%. This study evaluates the ORI to PaO2 relationship during surgery. We studied patients undergoing scheduled surgery in which arterial catheterization and intraoperative arterial blood gas analysis were planned. Data from multiple pulse co-oximetry sensors on each patient were continuously collected and stored on a research computer. Regression analysis was used to compare ORI with PaO2 obtained from each arterial blood gas measurement and changes in ORI with changes in PaO2 from sequential measurements. Linear mixed-effects regression models for repeated measures were then used to account for within-subject correlation across the repeatedly measured PaO2 and ORI and for the unequal time intervals of PaO2 determination over elapsed surgical time. Regression plots were inspected for ORI values corresponding to PaO2 of 100 and 150 mm Hg. ORI and PaO2 were compared using mixed-effects models with a subject-specific random intercept. ORI values and PaO2 measurements were obtained from intraoperative data collected from 106 patients. Regression analysis showed that the ORI to PaO2 relationship was stronger for PaO2 to 240 mm Hg (r = 0.536) than for PaO2 over 240 mm Hg (r = 0.0016). Measured PaO2 was ≥100 mm Hg for all ORI over 0.24. Measured PaO2 was ≥150 mm Hg in 96.6% of samples when ORI was over 0.55. A random intercept variance component linear mixed-effects model for repeated measures indicated that PaO2 was significantly related to ORI (β[95% confidence interval] = 0.002 [0.0019-0.0022]; P < 0.0001). A similar analysis indicated a significant relationship between change in PaO2 and change in ORI (β [95% confidence interval] = 0.0044 [0.0040-0.0048]; P < 0.0001). These findings suggest that ORI >0.24 can distinguish PaO2 ≥100 mm Hg when SpO2 is over 98%. Similarly, ORI > 0.55 appears to be a threshold to distinguish PaO2 ≥150 mm Hg. The usefulness of these values should be evaluated prospectively. Decreases in ORI to near 0.24 may provide advance indication of falling PaO2 approaching 100 mm Hg when SpO2 is >98%. The clinical utility of interventions based on continuous ORI monitoring should be studied prospectively.
Tandem-repeat protein domains across the tree of life
Jernigan, Kristin K.
2015-01-01
Tandem-repeat protein domains, composed of repeated units of conserved stretches of 20–40 amino acids, are required for a wide array of biological functions. Despite their diverse and fundamental functions, there has been no comprehensive assessment of their taxonomic distribution, incidence, and associations with organismal lifestyle and phylogeny. In this study, we assess for the first time the abundance of armadillo (ARM) and tetratricopeptide (TPR) repeat domains across all three domains in the tree of life and compare the results to our previous analysis on ankyrin (ANK) repeat domains in this journal. All eukaryotes and a majority of the bacterial and archaeal genomes analyzed have a minimum of one TPR and ARM repeat. In eukaryotes, the fraction of ARM-containing proteins is approximately double that of TPR and ANK-containing proteins, whereas bacteria and archaea are enriched in TPR-containing proteins relative to ARM- and ANK-containing proteins. We show in bacteria that phylogenetic history, rather than lifestyle or pathogenicity, is a predictor of TPR repeat domain abundance, while neither phylogenetic history nor lifestyle predicts ARM repeat domain abundance. Surprisingly, pathogenic bacteria were not enriched in TPR-containing proteins, which have been associated within virulence factors in certain species. Taken together, this comparative analysis provides a newly appreciated view of the prevalence and diversity of multiple types of tandem-repeat protein domains across the tree of life. A central finding of this analysis is that tandem repeat domain-containing proteins are prevalent not just in eukaryotes, but also in bacterial and archaeal species. PMID:25653910
Yusof, Mohd Yusmiaidil Putera Mohd; Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham
2017-12-01
This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.
Predonation screening of candidate donors and prevention of window period donations.
Lieshout-Krikke, Ryanne W; Zaaijer, Hans L; van de Laar, Thijs J W
2015-02-01
Infectious window period donations slip through routine donor screening procedures. To explore the potential value of predonation screening of candidate donors, we compared the proportion of incident transfusion-transmissible infections in candidate donors, in first-time donors, and in repeat donors. A retrospective analysis was performed of all incident hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) infections in candidate, first-time, and repeat donors in the Netherlands during the period 2009 to 2013. In total, 176,716 candidate donors, 144,226 first-time donations, and 4,143,455 repeat donations were screened for HBV, HCV, and HIV infection. Acute HBV infection was identified in the predonation sample of six candidate donors. One first-time donor, testing HIV-negative at predonation screening, tested positive for anti-HIV and HIV RNA in the first donation 29 days later. Among repeat donations we identified 15, one, and six incident HBV, HCV and HIV infections, respectively. The proportion of incident infections among candidate donors/first-time donations/repeat donations was for HBV, 3.40/0/0.36; for HCV, 0/0/0.02; and for HIV 0/0.69/0.14 per 100,000, respectively. Predonation screening of candidate donors very likely causes a loss of donations, but it might prevent undetected window period donations. Further studies are necessary to determine the value of predonation screening as an additional safety measure. © 2014 AABB.
A Review of Calibration Transfer Practices and Instrument Differences in Spectroscopy.
Workman, Jerome J
2018-03-01
Calibration transfer for use with spectroscopic instruments, particularly for near-infrared, infrared, and Raman analysis, has been the subject of multiple articles, research papers, book chapters, and technical reviews. There has been a myriad of approaches published and claims made for resolving the problems associated with transferring calibrations; however, the capability of attaining identical results over time from two or more instruments using an identical calibration still eludes technologists. Calibration transfer, in a precise definition, refers to a series of analytical approaches or chemometric techniques used to attempt to apply a single spectral database, and the calibration model developed using that database, for two or more instruments, with statistically retained accuracy and precision. Ideally, one would develop a single calibration for any particular application, and move it indiscriminately across instruments and achieve identical analysis or prediction results. There are many technical aspects involved in such precision calibration transfer, related to the measuring instrument reproducibility and repeatability, the reference chemical values used for the calibration, the multivariate mathematics used for calibration, and sample presentation repeatability and reproducibility. Ideally, a multivariate model developed on a single instrument would provide a statistically identical analysis when used on other instruments following transfer. This paper reviews common calibration transfer techniques, mostly related to instrument differences, and the mathematics of the uncertainty between instruments when making spectroscopic measurements of identical samples. It does not specifically address calibration maintenance or reference laboratory differences.
A new method for the assessment of the surface topography of NiTi rotary instruments.
Ferreira, F; Barbosa, I; Scelza, P; Russano, D; Neff, J; Montagnana, M; Zaccaro Scelza, M
2017-09-01
To describe a new method for the assessment of nanoscale alterations in the surface topography of nickel-titanium endodontic instruments using a high-resolution optical method and to verify the accuracy of the technique. Noncontact three-dimensional optical profilometry was used to evaluate defects on a size 25, .08 taper reciprocating instrument (WaveOne ® ), which was subjected to a cyclic fatigue test in a simulated root canal in a clear resin block. For the investigation, an original procedure was established for the analysis of similar areas located 3 mm from the tip of the instrument before and after canal preparation to enable the repeatability and reproducibility of the measurements with precision. All observations and analysis were taken in areas measuring 210 × 210 μm provided by the software of the equipment. The three-dimensional high-resolution image analysis showed clear alterations in the surface topography of the examined cutting blade and flute of the instrument, before and after use, with the presence of surface irregularities such as deformations, debris, grooves, cracks, steps and microcavities. Optical profilometry provided accurate qualitative nanoscale evaluation of similar surfaces before and after the fatigue test. The stability and repeatability of the technique enables a more comprehensive understanding of the effects of wear on the surface of endodontic instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Lower-extremity biomechanics during forward and lateral stepping activities in older adults
Wang, Man-Ying; Flanagan, Sean; Song, Joo-Eun; Greendale, Gail A.; Salem, George J.
2012-01-01
Objective To characterize the lower-extremity biomechanics associated with stepping activities in older adults. Design Repeated-measures comparison of kinematics and kinetics associated with forward step-up and lateral step-up activities. Background Biomechanical analysis may be used to assess the effectiveness of various ‘in-home activities’ in targeting appropriate muscle groups and preserving functional strength and power in elders. Methods Data were analyzed from 21 participants (mean 74.7 yr (standard deviation, 4.4 yr)) who performed the forward and lateral step-up activities while instrumented for biomechanical analysis. Motion analysis equipment, inverse dynamics equations, and repeated measures anovas were used to contrast the maximum joint angles, peak net joint moments, angular impulse, work, and power associated with the activities. Results The lateral step-up resulted in greater maximum knee flexion (P < 0.001) and ankle dorsiflexion angles (P < 0.01). Peak joint moments were similar between exercises. The forward step-up generated greater peak hip power (P < 0.05) and total work (P < 0.001); whereas, the lateral step-up generated greater impulse (P < 0.05), work (P < 0.01), and power (P < 0.05) at the knee and ankle. Conclusions In older adults, the forward step-up places greater demand on the hip extensors, while lateral step-up places greater demand on the knee extensors and ankle plantar flexors. PMID:12620784
Amino acid sequence analysis of the annexin super-gene family of proteins.
Barton, G J; Newman, R H; Freemont, P S; Crumpton, M J
1991-06-15
The annexins are a widespread family of calcium-dependent membrane-binding proteins. No common function has been identified for the family and, until recently, no crystallographic data existed for an annexin. In this paper we draw together 22 available annexin sequences consisting of 88 similar repeat units, and apply the techniques of multiple sequence alignment, pattern matching, secondary structure prediction and conservation analysis to the characterisation of the molecules. The analysis clearly shows that the repeats cluster into four distinct families and that greatest variation occurs within the repeat 3 units. Multiple alignment of the 88 repeats shows amino acids with conserved physicochemical properties at 22 positions, with only Gly at position 23 being absolutely conserved in all repeats. Secondary structure prediction techniques identify five conserved helices in each repeat unit and patterns of conserved hydrophobic amino acids are consistent with one face of a helix packing against the protein core in predicted helices a, c, d, e. Helix b is generally hydrophobic in all repeats, but contains a striking pattern of repeat-specific residue conservation at position 31, with Arg in repeats 4 and Glu in repeats 2, but unconserved amino acids in repeats 1 and 3. This suggests repeats 2 and 4 may interact via a buried saltbridge. The loop between predicted helices a and b of repeat 3 shows features distinct from the equivalent loop in repeats 1, 2 and 4, suggesting an important structural and/or functional role for this region. No compelling evidence emerges from this study for uteroglobin and the annexins sharing similar tertiary structures, or for uteroglobin representing a derivative of a primordial one-repeat structure that underwent duplication to give the present day annexins. The analyses performed in this paper are re-evaluated in the Appendix, in the light of the recently published X-ray structure for human annexin V. The structure confirms most of the predictions and shows the power of techniques for the determination of tertiary structural information from the amino acid sequences of an aligned protein family.
Freitas, Tomás T; Calleja-González, Julio; Alarcón, Francisco; Alcaraz, Pedro E
2016-02-01
This study aimed to investigate the acute effects of two different resistance circuit training protocols on basketball players' physical and technical performance and rating of perceived exertion (RPE). In a repeated-measures, crossover experimental design, 9 semiprofessional basketball players performed a Power Circuit Training (PCT; 45% 1RM) and a High-Resistance Circuit Training (HRC; 6RM), on consecutive weeks. Vertical and horizontal jump performance, 3-points shooting accuracy, repeated-sprint ability (RSA), agility, and upper body power output were measured before and after training. The RPE was assessed 20 minutes after resistance training. One-way repeated-measures analysis of variance showed performance decrements in vertical jump height and peak power, horizontal jump distance, 3-points percentage, bench-press power output, RSA total and ideal time, and agility T-Test at total time following HRC, but not PCT (p ≤ 0.05). The RPE was higher in HRC compared with PCT. The results of this study indicated that HRC was perceived as being harder and produced higher fatigue levels, which in turn lowered acute performance. However, low-to-moderate intensity loads did not negatively affect performance. Thus, completing a PCT session may be the most appropriate option before a practice or game as it avoids acute-resistance-training-induced performance decrements. However, if the objective of the basketball session is to develop or perfect technical skills during fatiguing conditions, HRC may be the more suitable option.
Acquisition of Motor and Cognitive Skills through Repetition in Typically Developing Children
Magallón, Sara; Narbona, Juan; Crespo-Eguílaz, Nerea
2016-01-01
Background Procedural memory allows acquisition, consolidation and use of motor skills and cognitive routines. Automation of procedures is achieved through repeated practice. In children, improvement in procedural skills is a consequence of natural neurobiological development and experience. Methods The aim of the present research was to make a preliminary evaluation and description of repetition-based improvement of procedures in typically developing children (TDC). Ninety TDC children aged 6–12 years were asked to perform two procedural learning tasks. In an assembly learning task, which requires predominantly motor skills, we measured the number of assembled pieces in 60 seconds. In a mirror drawing learning task, which requires more cognitive functions, we measured time spent and efficiency. Participants were tested four times for each task: three trials were consecutive and the fourth trial was performed after a 10-minute nonverbal interference task. The influence of repeated practice on performance was evaluated by means of the analysis of variance with repeated measures and the paired-sample test. Correlation coefficients and simple linear regression test were used to examine the relationship between age and performance. Results TDC achieved higher scores in both tasks through repetition. Older children fitted more pieces than younger ones in assembling learning and they were faster and more efficient at the mirror drawing learning task. Conclusions These findings indicate that three consecutive trials at a procedural task increased speed and efficiency, and that age affected basal performance in motor-cognitive procedures. PMID:27384671
Effect of short-term cold-water immersion on muscle pain sensitivity in elite track cyclists.
Klich, Sebastian; Krymski, Igor; Michalik, Kamil; Kawczyński, Adam
2018-05-01
To determine the effect of short-term cold-water immersion (CWI) on muscle pain sensitivity after maximal anaerobic power training in track cyclists. Repeated measures. University Laboratory. 12 elite sprint track cyclists (age 24,75 ± 4,23 years). PPT measurements were made on dominant lower extremity (right) in 20 reference points, including anterior thigh muscles, posterior thigh muscles and posterior cuff muscles. PPT levels were measured: 1) before workout, 2) immediately after workout, but before CWI 3) 1 h after CWI and 4) 12 h after CWI. Mean PPT values for each muscle group per participant were calculated for further statistical analysis. The average PPT for anterior thigh muscles decreased significantly after effort (p = 0.001) and increased significantly 1 h after CWI (p = 0.048). In posterior thigh muscles PPT decreased significantly after effort (p = 0.014) and increased significantly 1 h and 12 h after CWI (p = 0.045 and p = 0.25 respectively). However, in posterior cuff muscles PPT decreased only after effort (p = 0.001). Short-term repeated sprint exercise appears to affect PPT in track cyclists. This study have reported that CWI in 5 °C for 5 min have had a beneficial effect in minimizing PPT 1 h post repeated maximal sprint training. Copyright © 2018 Elsevier Ltd. All rights reserved.
Acquisition of Motor and Cognitive Skills through Repetition in Typically Developing Children.
Magallón, Sara; Narbona, Juan; Crespo-Eguílaz, Nerea
2016-01-01
Procedural memory allows acquisition, consolidation and use of motor skills and cognitive routines. Automation of procedures is achieved through repeated practice. In children, improvement in procedural skills is a consequence of natural neurobiological development and experience. The aim of the present research was to make a preliminary evaluation and description of repetition-based improvement of procedures in typically developing children (TDC). Ninety TDC children aged 6-12 years were asked to perform two procedural learning tasks. In an assembly learning task, which requires predominantly motor skills, we measured the number of assembled pieces in 60 seconds. In a mirror drawing learning task, which requires more cognitive functions, we measured time spent and efficiency. Participants were tested four times for each task: three trials were consecutive and the fourth trial was performed after a 10-minute nonverbal interference task. The influence of repeated practice on performance was evaluated by means of the analysis of variance with repeated measures and the paired-sample test. Correlation coefficients and simple linear regression test were used to examine the relationship between age and performance. TDC achieved higher scores in both tasks through repetition. Older children fitted more pieces than younger ones in assembling learning and they were faster and more efficient at the mirror drawing learning task. These findings indicate that three consecutive trials at a procedural task increased speed and efficiency, and that age affected basal performance in motor-cognitive procedures.
Al-Mahdawi, Sahar; Pinto, Ricardo Mouro; Varshney, Dhaval; Lawrence, Lorraine; Lowrie, Margaret B; Hughes, Sian; Webster, Zoe; Blake, Julian; Cooper, J Mark; King, Rosalind; Pook, Mark A
2006-11-01
Friedreich ataxia (FRDA) is a neurodegenerative disorder caused by an unstable GAA repeat expansion mutation within intron 1 of the FXN gene. However, the origins of the GAA repeat expansion, its unstable dynamics within different cells and tissues, and its effects on frataxin expression are not yet completely understood. Therefore, we have chosen to generate representative FRDA mouse models by using the human FXN GAA repeat expansion itself as the genetically modified mutation. We have previously reported the establishment of two lines of human FXN YAC transgenic mice that contain unstable GAA repeat expansions within the appropriate genomic context. We now describe the generation of FRDA mouse models by crossbreeding of both lines of human FXN YAC transgenic mice with heterozygous Fxn knockout mice. The resultant FRDA mice that express only human-derived frataxin show comparatively reduced levels of frataxin mRNA and protein expression, decreased aconitase activity, and oxidative stress, leading to progressive neurodegenerative and cardiac pathological phenotypes. Coordination deficits are present, as measured by accelerating rotarod analysis, together with a progressive decrease in locomotor activity and increase in weight. Large vacuoles are detected within neurons of the dorsal root ganglia (DRG), predominantly within the lumbar regions in 6-month-old mice, but spreading to the cervical regions after 1 year of age. Secondary demyelination of large axons is also detected within the lumbar roots of older mice. Lipofuscin deposition is increased in both DRG neurons and cardiomyocytes, and iron deposition is detected in cardiomyocytes after 1 year of age. These mice represent the first GAA repeat expansion-based FRDA mouse models that exhibit progressive FRDA-like pathology and thus will be of use in testing potential therapeutic strategies, particularly GAA repeat-based strategies.
ERIC Educational Resources Information Center
Pustejovsky, James E.
2013-01-01
Single-case designs (SCDs) are a class of research methods for evaluating intervention effects by taking repeated measurements of an outcome over time on a single case, both before and after the deliberate introduction of a treatment. SCDs are used heavily in fields such as special education, school psychology, social work, and applied behavior…
Ramesh Murthy; Stanley J. Zarnoch; P.M. Dougherty
1997-01-01
Repeated measures analysis was used to evaluate the effect of long-term CO2 enhancement on seasonal trends of light-saturated rates of net photosynthesis (Asat) and stomatal conductance to water vapour (gsat) of 9-year-old loblolly pine (Pinus taeda L.; trees grown in a 2x2...
ERIC Educational Resources Information Center
Carpino, Rachel; Walker, Mary P.; Liu, Ying; Simmer-Beck, Melanie
2017-01-01
This program evaluation examines the effectiveness of a school-based dental clinic. A repeated-measures design was used to longitudinally examine secondary data from participants (N = 293). Encounter intensity was developed to normalize data. Multivariate analysis of variance and Kruskal-Wallis test were used to investigate the effect of encounter…
Repeatable Reverse Engineering with PANDA
2015-12-08
that, even without 0e+00 2e+06 4e+06 6e+06 8e+06 1e+07 0 50 00 15 00 0 instruction count ta in te d co m pu ta tio n Fig. 5: Measure of tainted...AAI0807735. [8] Vitaly Chipounov, Volodymyr Kuznetsov, and George Candea. S2E: A platform for in-vivo multi-path analysis of software systems. In
StatCharrms is a graphical user front-end for ease of use in analyzing data generated from OCSPP 890.2200, Medaka Extended One Generation Reproduction Test (MEOGRT) and OCSPP 890.2300, Larval Amphibian Gonad Development Assay (LAGDA). The analyses StatCharrms is capable of perfor...
John J. Piccolo; Nicholas F. Hughes; Mason D. Bryant
2008-01-01
We examined the effects of water velocity on prey detection and capture by drift-feeding juvenile coho salmon (Oncorhynchus kisutch) and steelhead (sea-run rainbow trout,Oncorhynchus mykiss irideus) in laboratory experiments. We used repeated-measures analysis of variance to test the effects of velocity, species, and the velocity x species interaction on prey capture...
Curran, Patrick J.; Hussong, Andrea M.; Cai, Li; Huang, Wenjing; Chassin, Laurie; Sher, Kenneth J.; Zucker, Robert A.
2010-01-01
There are a number of significant challenges encountered when studying development over an extended period of time including subject attrition, changing measurement structures across group and developmental period, and the need to invest substantial time and money. Integrative data analysis is an emerging set of methodologies that overcomes many of the challenges of single sample designs through the pooling of data drawn from multiple existing developmental studies. This approach is characterized by a host of advantages, but this also introduces several new complexities that must be addressed prior to broad adoption by developmental researchers. In this paper we focus on methods for fitting measurement models and creating scale scores using data drawn from multiple longitudinal studies. We present findings from the analysis of repeated measures of internalizing symptomatology that were pooled from three existing developmental studies. We describe and demonstrate each step in the analysis and we conclude with a discussion of potential limitations and directions for future research. PMID:18331129
In vivo analysis of the iris thickness by spectral domain optical coherence tomography.
Invernizzi, Alessandro; Cigada, Mario; Savoldi, Luisa; Cavuto, Silvio; Fontana, Luigi; Cimino, Luca
2014-09-01
To assess the effectiveness of spectral domain optical coherence tomography (SD-OCT) in providing in vivo measurements of iris thickness in healthy and pathological subjects. 14 healthy volunteers and 14 patients with unilateral Fuchs' uveitis were enrolled in the study. The two groups were comparable for age, gender and race. Each subject underwent complete clinical examination and anterior segment SD-OCT imaging in both eyes. SD-OCT scans of the iris were performed following a cross-sectional pattern. Iris thickness values were obtained using a purposely developed software-based analysis of OCT images. Measurements were carried out twice by two trained independent operators to assess intraobserver and interobserver repeatability. Analysis of iris thickness was conducted in four main quadrants: superior, inferior, nasal and temporal. Iris thickness values from normal subjects were compared with the ones measured in the affected and fellow eyes of patients with Fuchs' uveitis. Iris thickness measurements showed good intraobserver and interobserver repeatability (intraclass correlation coefficient >0.971). Superior and temporal iris sectors showed respectively thickest and thinnest values in all groups. In healthy eyes, iris thickness ranged from 327.92±37.29 μm temporally to 405.25±48.49 μm superiorly. Iris thickness measurements in the affected eyes of Fuchs' uveitis patients ranged from 285.48±56.02 μm temporally to 376.12±60.97 μm superiorly. Multiple comparison analysis showed iris thickness values to be significantly lower in eyes affected by Fuchs' uveitis than both in fellow eyes (p<0.001) of the same patients and in healthy eyes (p=0.0074). SD-OCT is a suitable technique for iris thickness assessment. Thickness analysis must be carried out using a sectorial approach, taking into consideration anatomical variations existing between different iris regions. SD-OCT is a potentially useful tool for detecting iris thickness variations induced by pathological conditions such as Fuchs' uveitis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Validity of a questionnaire measuring motives for choosing foods including sustainable concerns.
Sautron, Valérie; Péneau, Sandrine; Camilleri, Géraldine M; Muller, Laurent; Ruffieux, Bernard; Hercberg, Serge; Méjean, Caroline
2015-04-01
Since the 1990s, sustainability of diet has become an increasingly important concern for consumers. However, there is no validated multidimensional measurement of motivation in the choice of foods including a concern for sustainability currently available. In the present study, we developed a questionnaire that measures food choice motives during purchasing, and we tested its psychometric properties. The questionnaire included 104 items divided into four predefined dimensions (environmental, health and well-being, economic and miscellaneous). It was administered to 1000 randomly selected subjects participating in the Nutrinet-Santé cohort study. Among 637 responders, one-third found the questionnaire complex or too long, while one-quarter found it difficult to fill in. Its underlying structure was determined by exploratory factor analysis and then internally validated by confirmatory factor analysis. Reliability was also assessed by internal consistency of selected dimensions and test-retest repeatability. After selecting the most relevant items, first-order analysis highlighted nine main dimensions: labeled ethics and environment, local and traditional production, taste, price, environmental limitations, health, convenience, innovation and absence of contaminants. The model demonstrated excellent internal validity (adjusted goodness of fit index = 0.97; standardized root mean square residuals = 0.07) and satisfactory reliability (internal consistency = 0.96, test-retest repeatability coefficient ranged between 0.31 and 0.68 over a mean 4-week period). This study enabled precise identification of the various dimensions in food choice motives and proposed an original, internally valid tool applicable to large populations for assessing consumer food motivation during purchasing, particularly in terms of sustainability. Copyright © 2014 Elsevier Ltd. All rights reserved.
Barboni, Mirella Telles Salgueiro; Szepessy, Zsuzsanna; Ventura, Dora Fix; Németh, János
2018-04-01
To establish fluctuation limits, it was considered that not only overall macular sensitivity but also fluctuations of individual test points in the macula might have clinical value. Three repeated measurements of microperimetry were performed using the Standard Expert test of Macular Integrity Assessment (MAIA) in healthy subjects ( N = 12, age = 23.8 ± 1.5 years old) and in patients with age-related macular degeneration (AMD) ( N = 11, age = 68.5 ± 7.4 years old). A total of 37 macular points arranged in four concentric rings and in four quadrants were analyzed individually and in groups. The data show low fluctuation of macular sensitivity of individual test points in healthy subjects (average = 1.38 ± 0.28 dB) and AMD patients (average = 2.12 ± 0.60 dB). Lower sensitivity points are more related to higher fluctuation than to the distance from the central point. Fixation stability showed no effect on the sensitivity fluctuation. The 95th percentile of the standard deviations of healthy subjects was, on average, 2.7 dB, ranging from 1.2 to 4 dB, depending on the point tested. Point analysis and regional analysis might be considered prior to evaluating macular sensitivity fluctuation in order to distinguish between normal variation and a clinical change. S tatistical methods were used to compare repeated microperimetry measurements and to establish fluctuation limits of the macular sensitivity. This analysis could add information regarding the integrity of different macular areas and provide new insights into fixation points prior to the biofeedback fixation training.
Validation of a Hartmann-Moiré wavefront sensor with large dynamic range.
Wei, Xin; Van Heugten, Tony; Thibos, Larry
2009-08-03
Our goal was to validate the accuracy, repeatability, sensitivity, and dynamic range of a Hartmann-Moiré (HM) wavefront sensor (PixelOptics, Inc.) designed for ophthalmic applications. Testing apparatus injected a 4 mm diameter monochromatic (532 nm) beam of light into the wavefront sensor for measurement. Controlled amounts of defocus and astigmatism were introduced into the beam with calibrated spherical (-20D to + 18D) and cylindrical (-8D to + 8D) lenses. Repeatability was assessed with three repeated measurements within a 2-minute period. Correlation coefficients between mean wavefront measurements (n = 3) and expected wavefront vergence for both sphere and cylinder lenses were >0.999. For spherical lenses, the sensor was accurate to within 0.1D over the range from -20D to + 18D. For cylindrical lenses, the sensor was accurate to within 0.1D over the range from -8D to + 8D. The primary limitation to demonstrating an even larger dynamic range was the increasingly critical requirements for optical alignment. Sensitivity to small changes of vergence was constant over the instrument's full dynamic range. Repeatability of measurements for fixed condition was within 0.01D. The Hartmann-Moiré wavefront sensor measures defocus and astigmatism accurately and repeatedly with good sensitivity over a large dynamic range required for ophthalmic applications.
NASA Astrophysics Data System (ADS)
Bao, Chuanchen; Li, Jiakun; Feng, Qibo; Zhang, Bin
2018-07-01
This paper introduces an error-compensation model for our measurement method to measure five motion errors of a rotary axis based on fibre laser collimation. The error-compensation model is established in a matrix form using the homogeneous coordinate transformation theory. The influences of the installation errors, error crosstalk, and manufacturing errors are analysed. The model is verified by both ZEMAX simulation and measurement experiments. The repeatability values of the radial and axial motion errors are significantly suppressed by more than 50% after compensation. The repeatability experiments of five degrees of freedom motion errors and the comparison experiments of two degrees of freedom motion errors of an indexing table were performed by our measuring device and a standard instrument. The results show that the repeatability values of the angular positioning error ε z and tilt motion error around the Y axis ε y are 1.2″ and 4.4″, and the comparison deviations of the two motion errors are 4.0″ and 4.4″, respectively. The repeatability values of the radial and axial motion errors, δ y and δ z , are 1.3 and 0.6 µm, respectively. The repeatability value of the tilt motion error around the X axis ε x is 3.8″.
Lyytinen, T.; Bragge, T.; Hakkarainen, M.; Liikavainio, T.; Karjalainen, P.A.; Arokoski, J.P.
2016-01-01
Objectives: To determine the repeatability of knee joint impulsive loading measurements with skin-mounted accelerometers (SMAs) and lower limb surface electromyography (EMG) recordings during gait. Methods: Triaxial SMA and EMG from 4 muscles during level and stair walking in nine healthy and nine knee osteoarthritis (OA) subjects were used. The initial peak acceleration (IPA), root mean square (RMS), maximal acceleration transient rate (ATRmax) and mean EMG activity (EMGact) were calculated. The coefficient of variation (CV) and the intraclass correlation coefficient (ICC) were calculated to measure repeatability. Results: The CV and ICC of RMS accelerations ranged from 4.9% to 10.9% and from 0.69 to 0.96 in both study groups during level walking. The CV and ICC of IPA and ATRmax varied from 7.7% to 14.2% and from 0.85 to 0.99 during level and stairs up walking in healthy subjects. The CV and ICC of EMGact ranged from 8.3% to 31.7% and from 0.16 to 0.97 in both study groups. Conclusions: RMS accelerations exhibited good repeatability during walking in healthy and knee OA subjects. The repeatability of EMG measurements was acceptable in healthy subjects depending on the measured muscles. PMID:26944825
Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging.
Notomi, Yuichi; Lysyansky, Peter; Setser, Randolph M; Shiota, Takahiro; Popović, Zoran B; Martin-Miklovic, Maureen G; Weaver, Joan A; Oryszak, Stephanie J; Greenberg, Neil L; White, Richard D; Thomas, James D
2005-06-21
We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach). Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence. We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI. Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images. Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias. The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology.
Intraoperative aberrometry-based aphakia refraction in patients with cataract: status and options.
Huelle, Jan O; Druchkiv, Vasyl; Habib, Nabil E; Richard, Gisbert; Katz, Toam; Linke, Stephan J
2017-02-01
To explore the application of intraoperative wavefront aberrometry (IWA) for aphakia-based biometry using three existing formulae derived from autorefractive retinoscopy and introducing new improved formulae. In 74 patients undergoing cataract surgery, three repeated measurements of aphakic spherical equivalent (SE) were taken. All measurements were objectively graded for their quality and evaluated with the 'limits of agreement' approach. ORs were calculated and analysis of variance was applied. The intraocular lens (IOL) power that would have given the target refraction was back-calculated from manifest refraction at 3 months postoperatively. Regression analysis was performed to generate two aphakic SE-based formulae for predicting this IOL. The accuracy of the formulae was determined by comparing them to conventional biometry and published aphakia formulae. In 32 eyes, three consecutive aphakic measurements were successful. Objective parameters of IWA map quality significantly impacted measurement variability (p<0.05). The limits of agreement of repeated aphakic SE readings were +0.66 dioptre (D) and -0.69 D. Intraoperative biometry by our formula resulted in 25% and 53% of all cases ±0.50D and ±1.00 D within SE target, respectively. A second formula that took axial length (AL) into account resulted in improved ratios of 41% and 70%, respectively. A reliable application of IWA to calculate IOL power during routine cataract surgery may not be feasible given the high rate of measurement failures and the large variations of the readings. To enable reliable IOL calculation from IWA, measurement precision must be improved and aphakic IOL formulae need to be fine-tuned. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Reliability of a Single Light Source Purkinjemeter in Pseudophakic Eyes.
Janunts, Edgar; Chashchina, Ekaterina; Seitz, Berthold; Schaeffel, Frank; Langenbucher, Achim
2015-08-01
To study the reliability of Purkinje image analysis for assessment of intraocular lens tilt and decentration in pseudophakic eyes. The study comprised 64 eyes of 39 patients. All eyes underwent phacoemulsification with intraocular lens implanted in the capsular bag. Lens decentration and tilt were measured multiple times by an infrared Purkinjemeter. A total of 396 measurements were performed 1 week and 1 month postoperatively. Lens tilt (Tx, Ty) and decentration (Dx, Dy) in horizontal and vertical directions, respectively, were calculated by dedicated software based on regression analysis for each measurement using only four images, and afterward, the data were averaged (mean values, MV) for repeated sequence of measurements. New software was designed by us for recalculating lens misalignment parameters offline, using a complete set of Purkinje images obtained through the repeated measurements (9 to 15 Purkinje images) (recalculated values, MV'). MV and MV' were compared using SPSS statistical software package. MV and MV' were found to be highly correlated for the Tx and Ty parameters (R2 > 0.9; p < 0.001), moderately correlated for the Dx parameter (R2 > 0.7; p < 0.001), and weakly correlated for the Dy parameter (R2 = 0.23; p < 0.05). Reliability was high (Cronbach α > 0.9) for all measured parameters. Standard deviation values were 0.86 ± 0.69 degrees, 0.72 ± 0.65 degrees, 0.04 ± 0.05 mm, and 0.23 ± 0.34 mm for Tx, Ty, Dx, and Dy, respectively. The Purkinjemeter demonstrated high reliability and reproducibility for lens misalignment parameters. To further improve reliability, we recommend capturing at least six Purkinje images instead of three.
Vocal function and upper airway thermoregulation in five different environmental conditions.
Sandage, Mary J; Connor, Nadine P; Pascoe, David D
2014-02-01
Phonation threshold pressure and perceived phonatory effort were hypothesized to increase and upper airway temperature to decrease following exposure to cold and/or dry air. Greater changes were expected with mouth versus nose breathing. In a within-participant repeated measures design, 15 consented participants (7 men, 8 women) completed 20-min duration trials to allow for adequate thermal equilibration for both nose and mouth breathing in 5 different environments: 3 temperatures (°C) matched for relative humidity (% RH), cold (15 °C, 40% RH), thermally neutral (25 °C, 40% RH), and hot (35 °C, 40% RH); and 2 temperatures with variable relative humidity to match vapor pressure for the neutral environment (25 °C, 40% RH), cold (15 °C, 74% RH) and hot (35 °C, 23% RH). Following each equilibration trial, measures were taken in this order: upper airway temperature (transnasal thermistor probe), phonation threshold pressure, and perceived phonatory effort. Data were analyzed using repeated measures analysis of variance, and no significant differences were established. The study hypotheses were not supported. Findings suggest that the upper airway is tightly regulated for temperature when challenged by a realistic range of temperature and relative humidity environments. This is the first study of its kind to include measurement of upper airway temperature in conjunction with measures of vocal function.
Doblas, Sabrina; Almeida, Gilberto S; Blé, François-Xavier; Garteiser, Philippe; Hoff, Benjamin A; McIntyre, Dominick J O; Wachsmuth, Lydia; Chenevert, Thomas L; Faber, Cornelius; Griffiths, John R; Jacobs, Andreas H; Morris, David M; O'Connor, James P B; Robinson, Simon P; Van Beers, Bernard E; Waterton, John C
2015-12-01
To evaluate between-site agreement of apparent diffusion coefficient (ADC) measurements in preclinical magnetic resonance imaging (MRI) systems. A miniaturized thermally stable ice-water phantom was devised. ADC (mean and interquartile range) was measured over several days, on 4.7T, 7T, and 9.4T Bruker, Agilent, and Magnex small-animal MRI systems using a common protocol across seven sites. Day-to-day repeatability was expressed as percent variation of mean ADC between acquisitions. Cross-site reproducibility was expressed as 1.96 × standard deviation of percent deviation of ADC values. ADC measurements were equivalent across all seven sites with a cross-site ADC reproducibility of 6.3%. Mean day-to-day repeatability of ADC measurements was 2.3%, and no site was identified as presenting different measurements than others (analysis of variance [ANOVA] P = 0.02, post-hoc test n.s.). Between-slice ADC variability was negligible and similar between sites (P = 0.15). Mean within-region-of-interest ADC variability was 5.5%, with one site presenting a significantly greater variation than the others (P = 0.0013). Absolute ADC values in preclinical studies are comparable between sites and equipment, provided standardized protocols are employed. © 2015 Wiley Periodicals, Inc.
Gąsior, Jakub S.; Sacha, Jerzy; Jeleń, Piotr J.; Zieliński, Jakub; Przybylski, Jacek
2016-01-01
Background: Since heart rate variability (HRV) is associated with average heart rate (HR) and respiratory rate (RespRate), alterations in these parameters may impose changes in HRV. Hence the repeatability of HRV measurements may be affected by differences in HR and RespRate. The study aimed to evaluate HRV repeatability and its association with changes in HR and RespRate. Methods: Forty healthy volunteers underwent two ECG examinations 7 days apart. Standard HRV indices were calculated from 5-min ECG recordings. The ECG-derived respiration signal was estimated to assess RespRate. To investigate HR impact on HRV, HRV parameters were corrected for prevailing HR. Results: Differences in HRV parameters between the measurements were associated with the changes in HR and RespRate. However, in multiple regression analysis only HR alteration proved to be independent determinant of the HRV differences—every change in HR by 1 bpm changed HRV values by 16.5% on average. After overall removal of HR impact on HRV, coefficients of variation of the HRV parameters significantly dropped on average by 26.8% (p < 0.001), i.e., by the same extent HRV reproducibility improved. Additionally, the HRV correction for HR decreased association between RespRate and HRV. Conclusions: In stable conditions, HR but not RespRate is the most powerful factor determining HRV reproducibility and even a minimal change of HR may considerably alter HRV. However, the removal of HR impact may significantly improve HRV repeatability. The association between HRV and RespRate seems to be, at least in part, HR dependent. PMID:27588006
NASA Astrophysics Data System (ADS)
Medina-Marquez, J.; Balderas-Mata, S. E.; Flores, Jorge L.
2016-09-01
The study of the influence of the aperture size over the measurements of the L*a*b chromatic coordinates in spectrocolorimeters, in particular, the Macbeth 7000A ® spectrocolorimeter with an illumination/detection geometry d/8°. This is of importance due to the fact that many industry laboratories use it. This study will give us an invaluable insight of the variations in the measurements of the chromatic coordinates in the visible spectrum range regarding to three different aperture sizes; 2,5cm (AL), 1cm (AM), and 0,5cm (AS). The measurements are carried out on 13 Reference Materials (RMs) or diffusers with different hue under the following metrics; including specular component (SCI), excluding ultraviolet component (UVex), D65 illuminant, and 2° observer. The analysis and quantification of the data were done by the use of statistical tools such as variance analysis and Mendel parameters. In this work the analysis of the latter measurements as well as the methodology that quantifies the accuracy and precision of the method, i.e., repeatability and reproducibility, are presented.
Inmate responses to prison-based drug treatment: a repeated measures analysis.
Welsh, Wayne N
2010-06-01
Using a sample of 347 prison inmates and general linear modeling (GLM) repeated measures analyses, this paper examined during-treatment responses (e.g., changes in psychological and social functioning) to prison-based TC drug treatment. These effects have rarely been examined in previous studies, and never with a fully multivariate model accounting for within-subjects effects (changes over time), between-subjects effects (e.g., levels of risk and motivation), and within/between-subjects interactions (timexriskxmotivation). The results provide evidence of positive inmate change in response to prison TC treatment, but the patterns of results varied depending upon: (a) specific indicators of psychological and social functioning, motivation, and treatment process; (b) the time periods examined (1, 6, and 12 months during treatment); and (c) baseline levels of risk and motivation. Significant interactions between time and type of inmate suggest important new directions for research, theory, and practice in offender-based substance abuse treatment. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
A Vignette (User's Guide) for “An R Package for Statistical ...
StatCharrms is a graphical user front-end for ease of use in analyzing data generated from OCSPP 890.2200, Medaka Extended One Generation Reproduction Test (MEOGRT) and OCSPP 890.2300, Larval Amphibian Gonad Development Assay (LAGDA). The analyses StatCharrms is capable of performing are: Rao-Scott adjusted Cochran-Armitage test for trend By Slices (RSCABS), a Standard Cochran-Armitage test for trend By Slices (SCABS), mixed effects Cox proportional model, Jonckheere-Terpstra step down trend test, Dunn test, one way ANOVA, weighted ANOVA, mixed effects ANOVA, repeated measures ANOVA, and Dunnett test. This document provides a User’s Manual (termed a Vignette by the Comprehensive R Archive Network (CRAN)) for the previously created R-code tool called StatCharrms (Statistical analysis of Chemistry, Histopathology, and Reproduction endpoints using Repeated measures and Multi-generation Studies). The StatCharrms R-code has been publically available directly from EPA staff since the approval of OCSPP 890.2200 and 890.2300, and now is available publically available at the CRAN.
The effect of a family-based intervention with a cognitive-behavioral approach on elder abuse.
Khanlary, Zahra; Maarefvand, Masoomeh; Biglarian, Akbar; Heravi-Karimooi, Majideh
2016-01-01
Elder abuse may become a health issue in developing countries, including Iran. The purpose of this investigation was to study the effectiveness of Family-Based Cognitive-Behavioral Social Work (FBCBSW) in reducing elder abuse. In a randomized clinical trial in Iran, 27 elders participated in intervention and control groups. The intervention groups received a five-session FBCBSW intervention and completed the Domestic-Elder-Abuse-Questionnaire (DEAQ), which evaluates elder abuse at baseline and follow-ups. Repeated measures of analysis of variance (ANOVA) and the Wilcoxon test were used to analyze the data. The repeated measures ANOVA revealed that FBCBSW was successful in reducing elder abuse. The Wilcoxon test indicated that emotional neglect, care neglect, financial neglect, curtailment of personal autonomy, psychological abuse, and financial abuse significantly decreased over time, but there was no statistically significant difference in physical abuse before and after the intervention. The findings from this study suggest that FBCBSW is a promising approach to reducing elder abuse and warrants further study with larger samples.
Flexible modulation of network connectivity related to cognition in Alzheimer's disease.
McLaren, Donald G; Sperling, Reisa A; Atri, Alireza
2014-10-15
Functional neuroimaging tools, such as fMRI methods, may elucidate the neural correlates of clinical, behavioral, and cognitive performance. Most functional imaging studies focus on regional task-related activity or resting state connectivity rather than how changes in functional connectivity across conditions and tasks are related to cognitive and behavioral performance. To investigate the promise of characterizing context-dependent connectivity-behavior relationships, this study applies the method of generalized psychophysiological interactions (gPPI) to assess the patterns of associative-memory-related fMRI hippocampal functional connectivity in Alzheimer's disease (AD) associated with performance on memory and other cognitively demanding neuropsychological tests and clinical measures. Twenty-four subjects with mild AD dementia (ages 54-82, nine females) participated in a face-name paired-associate encoding memory study. Generalized PPI analysis was used to estimate the connectivity between the hippocampus and the whole brain during encoding. The difference in hippocampal-whole brain connectivity between encoding novel and encoding repeated face-name pairs was used in multiple-regression analyses as an independent predictor for 10 behavioral, neuropsychological and clinical tests. The analysis revealed connectivity-behavior relationships that were distributed, dynamically overlapping, and task-specific within and across intrinsic networks; hippocampal-whole brain connectivity-behavior relationships were not isolated to single networks, but spanned multiple brain networks. Importantly, these spatially distributed performance patterns were unique for each measure. In general, out-of-network behavioral associations with encoding novel greater than repeated face-name pairs hippocampal-connectivity were observed in the default-mode network, while correlations with encoding repeated greater than novel face-name pairs hippocampal-connectivity were observed in the executive control network (p<0.05, cluster corrected). Psychophysiological interactions revealed significantly more extensive and robust associations between paired-associate encoding task-dependent hippocampal-whole brain connectivity and performance on memory and behavioral/clinical measures than previously revealed by standard activity-behavior analysis. Compared to resting state and task-activation methods, gPPI analyses may be more sensitive to reveal additional complementary information regarding subtle within- and between-network relations. The patterns of robust correlations between hippocampal-whole brain connectivity and behavioral measures identified here suggest that there are 'coordinated states' in the brain; that the dynamic range of these states is related to behavior and cognition; and that these states can be observed and quantified, even in individuals with mild AD. Copyright © 2014 Elsevier Inc. All rights reserved.
Global positioning system measurements for crustal deformation: Precision and accuracy
Prescott, W.H.; Davis, J.L.; Svarc, J.L.
1989-01-01
Analysis of 27 repeated observations of Global Positioning System (GPS) position-difference vectors, up to 11 kilometers in length, indicates that the standard deviation of the measurements is 4 millimeters for the north component, 6 millimeters for the east component, and 10 to 20 millimeters for the vertical component. The uncertainty grows slowly with increasing vector length. At 225 kilometers, the standard deviation of the measurement is 6, 11, and 40 millimeters for the north, east, and up components, respectively. Measurements with GPS and Geodolite, an electromagnetic distance-measuring system, over distances of 10 to 40 kilometers agree within 0.2 part per million. Measurements with GPS and very long baseline interferometry of the 225-kilometer vector agree within 0.05 part per million.
Measuring fire spread rates from repeat pass airborne thermal infrared imagery
Douglas A. Stow; Philip J. Riggan; Emanual A. Storey; Lloyd L. Coulter
2014-01-01
The objective is to evaluate procedures for direct measurement of fire spread rates (FSRs) based on archived repeat pass airborne thermal infrared (ATIR) imagery and to identify requirements for more refined measurements of FSR and environmental factors that influence FSR. Flaming front positions are delineated on sequential FireMapper ATIR images captured at...
Statistical Enrichment of Epigenetic States Around Triplet Repeats that Can Undergo Expansions
Essebier, Alexandra; Vera Wolf, Patricia; Cao, Minh Duc; Carroll, Bernard J.; Balasubramanian, Sureshkumar; Bodén, Mikael
2016-01-01
More than 30 human genetic diseases are linked to tri-nucleotide repeat expansions. There is no known mechanism that explains repeat expansions in full, but changes in the epigenetic state of the associated locus has been implicated in the disease pathology for a growing number of examples. A comprehensive comparative analysis of the genomic features associated with diverse repeat expansions has been lacking. Here, in an effort to decipher the propensity of repeats to undergo expansion and result in a disease state, we determine the genomic coordinates of tri-nucleotide repeat tracts at base pair resolution and computationally establish epigenetic profiles around them. Using three complementary statistical tests, we reveal that several epigenetic states are enriched around repeats that are associated with disease, even in cells that do not harbor expansion, relative to a carefully stratified background. Analysis of over one hundred cell types reveals that epigenetic states generally tend to vary widely between genic regions and cell types. However, there is qualified consistency in the epigenetic signatures of repeats associated with disease suggesting that changes to the chromatin and the DNA around an expanding repeat locus are likely to be similar. These epigenetic signatures may be exploited further to develop models that could explain the propensity of repeats to undergo expansions. PMID:27013954
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
NASA Astrophysics Data System (ADS)
Jansen, Daniela; Weikusat, Ilka; Kleiner, Thomas; Wilhelms, Frank; Dahl-Jensen, Dorthe; Frenzel, Andreas; Binder, Tobias; Eichler, Jan; Faria, Sergio H.; Sheldon, Simon; Panton, Christian; Kipfstuhl, Sepp; Miller, Heinrich
2017-04-01
The European Project for Ice Coring in Antarctica (EPICA) ice core was drilled between 2001 and 2006 at the Kohnen Station, Antarctica. During the drilling process the borehole was logged repeatedly. Repeated logging of the borehole shape is a means of directly measuring the deformation of the ice sheet not only on the surface but also with depth, and to derive shear strain rates for the lower part, which control the volume of ice transported from the inner continent towards the ocean. The logging system continuously recorded the tilt of the borehole with respect to the vertical (inclination) as well as the heading of the borehole with respect to magnetic north (azimuth) by means of a compass. This dataset provides the basis for a 3-D reconstruction of the borehole shape, which is changing over time according to the predominant deformation modes with depth. The information gained from this analysis can then be evaluated in combination with lattice preferred orientation, grain size and grain shape derived by microstructural analysis of samples from the deep ice core. Additionally, the diameter of the borehole, which was originally circular with a diameter of 10 cm, was measured. As the ice flow velocity at the position of the EDML core is relatively slow (about 0.75 m/a), the changes of borehole shape between the logs during the drilling period were very small and thus difficult to interpret. Thus, the site has been revisited in the Antarctic summer season 2016 and logged again using the same measurement system. The change of the borehole inclination during the time period of 10 years clearly reveals the transition from a pure shear dominated deformation in the upper part of the ice sheet to shear deformation at the base. We will present a detailed analysis of the borehole parameters and the deduced shear strain rates in the lower part of the ice sheet. The results are discussed with respect to ice microstructural data derived from the EDML ice core. Microstructural data directly reflect the deformation conditions, as the ice polycrystal performs the deformation which leads e.g. to characteristic lattice orientation distributions and grain size and shape appearance. Though overprinted by recrystallization (due to the hot environment for the ice) and the slow deformation, analysis of statistically significant grain numbers reveals indications typical for the changing deformation regimes with depth. Additionally we compare our results with strain rates derived from a simulation with a model for large scale ice deformation, the Parallel Ice Sheet Model (PISM).
Accuracy Analysis and Validation of the Mars Science Laboratory (MSL) Robotic Arm
NASA Technical Reports Server (NTRS)
Collins, Curtis L.; Robinson, Matthew L.
2013-01-01
The Mars Science Laboratory (MSL) Curiosity Rover is currently exploring the surface of Mars with a suite of tools and instruments mounted to the end of a five degree-of-freedom robotic arm. To verify and meet a set of end-to-end system level accuracy requirements, a detailed positioning uncertainty model of the arm was developed and exercised over the arm operational workspace. Error sources at each link in the arm kinematic chain were estimated and their effects propagated to the tool frames.A rigorous test and measurement program was developed and implemented to collect data to characterize and calibrate the kinematic and stiffness parameters of the arm. Numerous absolute and relative accuracy and repeatability requirements were validated with a combination of analysis and test data extrapolated to the Mars gravity and thermal environment. Initial results of arm accuracy and repeatability on Mars demonstrate the effectiveness of the modeling and test program as the rover continues to explore the foothills of Mount Sharp.
NASA Astrophysics Data System (ADS)
Cabalín, L. M.; González, A.; Ruiz, J.; Laserna, J. J.
2010-08-01
Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s - 1 . Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.
Analysis of automatic repeat request methods for deep-space downlinks
NASA Technical Reports Server (NTRS)
Pollara, F.; Ekroot, L.
1995-01-01
Automatic repeat request (ARQ) methods cannot increase the capacity of a memoryless channel. However, they can be used to decrease the complexity of the channel-coding system to achieve essentially error-free transmission and to reduce link margins when the channel characteristics are poorly predictable. This article considers ARQ methods on a power-limited channel (e.g., the deep-space channel), where it is important to minimize the total power needed to transmit the data, as opposed to a bandwidth-limited channel (e.g., terrestrial data links), where the spectral efficiency or the total required transmission time is the most relevant performance measure. In the analysis, we compare the performance of three reference concatenated coded systems used in actual deep-space missions to that obtainable by ARQ methods using the same codes, in terms of required power, time to transmit with a given number of retransmissions, and achievable probability of word error. The ultimate limits of ARQ with an arbitrary number of retransmissions are also derived.
A Repeated Power Training Enhances Fatigue Resistance While Reducing Intraset Fluctuations.
Gonzalo-Skok, Oliver; Tous-Fajardo, Julio; Moras, Gerard; Arjol-Serrano, José Luis; Mendez-Villanueva, Alberto
2018-04-04
Oliver, GS, Julio, TF, Moras, G, José Luis, AS, and Alberto, MV. A repeated power training enhances fatigue resistance while reducing intraset fluctuations. J Strength Cond Res XX(X): 000-000, 2018-The present study analyzed the effects of adding an upper-body repeated power ability (RPA) training to habitual strength training sessions. Twenty young elite male basketball players were randomly allocated into a control group (CON, n = 10) or repeated power group (RPG, n = 10) and evaluated by 1 repetition maximum (1RM), incremental load, and RPA tests in the bench press exercise before and after a 7-week period and a 4-week cessation period. Repeated power group performed 1-3 blocks of 5 sets of 5 repetitions using the load that maximized power output with 30 seconds and 3 minute of passive recovery between sets and blocks, respectively. Between-group analysis showed substantial greater improvements in RPG compared with CON in: best set (APB), last set (APL), mean power over 5 sets (APM), percentage of decrement, fluctuation decrease during APL and RPA index (APLpost/APBpre) during the RPA test (effect size [ES] = 0.64-1.86), and 1RM (ES = 0.48) and average power at 80% of 1RM (ES = 1.11) in the incremental load test. The improvements of APB and APM were almost perfectly correlated. In conclusion, RPA training represents an effective method to mainly improve fatigue resistance together with the novel finding of a better consistency in performance (measured as reduced intraset power fluctuations) at the end of a dynamic repeated effort.
Bussey, C T; Leeuw, A E de; Cook, R F; Ashley, Z; Schofield, J; Lamberts, R R
2014-07-01
Expansion of physiological knowledge increasingly requires examination of processes in the normal, conscious state. The current study describes a novel approach combining surgical implantation of radio-telemeters with vascular access ports (VAPs) to allow repeated hemodynamic and pharmacological measures in conscious rats. Dual implantation was conducted on 16-week-old male lean and obese Zucker rats. Continued viability one month after surgery was observed in 67% of lean and 44% of obese animals, giving an overall 54% completion rate. Over the five-week measurement period, reliable and reproducible basal mean arterial pressure and heart rate measures were observed. VAP patency and receptor-independent vascular reactivity were confirmed by consistent hemodynamic responses to sodium nitroprusside (6.25 µg/kg). Acutely, minimal hemodynamic responses to repeated bolus administration of 0.2 mL saline indicated no significant effect of increased blood volume or administration stress, making repeated acute measures viable. Similarly, repeated administration of the β-adrenoceptor agonist dobutamine (30 µg/kg) at 10 min intervals resulted in reproducible hemodynamic changes in both lean and obese animals. Therefore, our study demonstrates that this new approach is viable for the acute and chronic assessment of hemodynamic and pharmacological responses in both lean and obese conscious rats. This technique reduces the demand for animal numbers and allows hemodynamic measures with minimal disruption to animals' welfare, while providing reliable and reproducible results over several weeks. In conclusion, dual implantation of a radio-telemeter and VAP introduces a valuable technique for undertaking comprehensive studies involving repeated pharmacological tests in conscious animals to address important physiological questions. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Effects of topical anaesthetics and repeated tonometry on intraocular pressure.
Jóhannesson, Gauti; Hallberg, Per; Eklund, Anders; Behndig, Anders; Lindén, Christina
2014-03-01
To investigate the effects of repeated measurements of intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) to identify mechanisms contributing to the expected IOP reduction. A prospective, single-centre study with six healthy volunteers. Consecutive repeated series (six measurements/serie/method) were made alternately on both eyes for 1 hr with oxybuprocaine/fluorescein in the right eye and tetracaine in the left. The left eye was Pentacam(®) photographed before and repeatedly for 20 min after the IOP measurements. On a separate occasion, the same volunteers received the same amount of anaesthetic drops for 1 hr but without repeated IOP measurements. A significant IOP reduction occurred with both ART and GAT in the oxybuprocaine-treated eye, -4.4 mmHg and -3.8 mmHg, respectively and with ART in the tetracaine eye, -2.1 mmHg. There was a significant difference in IOP reduction between the oxybuprocaine and tetracaine eyes with ART. There was a significant drop in anterior chamber volume (ACV) immediately after the IOP measurements, -12.6 μl that returned to pretrial level after 2 min. After 1 hr of receiving anaesthetic eye drops (without IOP measurements), the IOP decreased significantly in the oxybuprocaine eye for both ART and GAT, -3.1 and -1.7 mmHg, respectively, but not in the tetracaine eye (p = 0.72). The IOP reduction cannot be explained solely by aqueous humor being pressed out of the anterior chamber. While significant IOP reduction occurred with both tetracaine and oxybuprocaine after repeated mechanical applanation, the IOP reduction was significantly greater with oxybuprocaine. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.
Klein, Christian; Kinz, Wieland; Zembsch, Alexander; Groll-Knapp, Elisabeth; Kundi, Michael
2014-04-21
Currently, the metatarsophalangeal angle (hallux valgus angle) is measured based on radiographic images. However, using X-ray examinations for epidemiological or screening purposes would be unethical, especially in children. For this reason it is discussed to measure the hallux valgus angle of the margo medialis pedis (medial border of the foot) documented on foot outline drawings or foot scans. As a first step on the way to prove the validity of those approaches this study assesses the hallux valgus angle measured on the margo medialis pedis based on the same x-ray pictures as the metatarsophalangeal hallux valgus. Radiographic images of the foot were obtained from patients with symptomatic hallux valgus malformation. Twelve sets of contact copies of the 63 originals were made, and were marked and measured according to three different methods, each one performed by two observers and with two repeated measurements. Thus, data sets from 756 individual assessments were entered into the multifactorial statistical analysis.Comparisons were made between the angle of the margo medialis pedis and the metatarsophalangeal angle, which was determined by two different methods. To determine the inter- and intraobserver reliability of the different methods, each assessment was conducted by two independent experts and repeated after a period of several weeks. The correlations between the hallux valgus angles determined by the three different methods were all above r=0.89 (p<0.001) and thus highly significant. The values obtained by measuring the margo medialis pedis angle, however, were on average 4.8 degrees smaller than the metatarsophalangeal angles. No significant differences were found between the observers. No systematic deviations for any observer between repeated measurements were detected. Measurements of the radiographic hallux angle of the margo medialis pedis are reliable and show high correlation with the metatarsophalangeal angle. Because the hallux valgus angles based on margo medialis pedis measurements were slightly but statistically significantly smaller, these measurements should be considered conservative estimates of the metatarsophalangeal angle. Significant differences between hallux valgus angles based on radiographic and non-radiographic material are unlikely. However this question has to be treated in a second stage in detail.
The Visi-Chroma VC-100: a new imaging colorimeter for dermatocosmetic research.
Barel, A O; Clarys, P; Alewaeters, K; Duez, C; Hubinon, J L; Mommaerts, M
2001-02-01
It was the aim of this study to carry out a comparative evaluation in vitro on standardized color charts and in vivo on healthy subjects using the Visi-Chroma VC-100, a new imaging tristimulus colorimeter and the Minolta Chromameter CR-200 as a reference instrument. The Visi-Chroma combines tristimulus color analysis with full color visualization of the skin area measured. The technical performances of both instruments were compared with the purpose of validating the use of this new imaging colorimeter in dermatocosmetic research. In vitro L*a*b* color parameters were taken with both instruments on standardized color charts (Macbeth and RAL charts) in order to evaluate accuracy, sensitivity range and repeatability. These measurements were completed by in vivo studies on different sites of human skin and studies of color changes induced by topical chemical agents on forearm skin. The accuracy, sensitivity range and repeatability of measurements of selected distances and surfaces in the measuring zone considered and specific color determinations of specific skin zones were also determined. The technical performance of this imaging colorimeter was rather good, with low coefficients of variation for repeatability of in vitro and vivo color measurements. High positive correlations were established in vitro and in vivo over a wide range of color measurements. The imaging colorimeter was able to measure the L*a*b* color parameters of specific chosen parts of the skin area considered and to measure accurately selected distances and surfaces in the same skin site considered. These comparative measurements show that both instruments have very similar technical performances and that high levels of correlation were obtained in vitro and in vivo using the L*a*b* color parameters. In addition, the Visi-Chroma presents the following improvements: 1) direct visualization and recording of the skin area considered with concomitant color measurements; 2) determination of the specific color parameters of skin areas chosen in the total measuring area; and 3) accurate determination of selected distances and surfaces in the same skin areas chosen.
Pain, Liza A M; Baker, Ross; Sohail, Qazi Zain; Richardson, Denyse; Zabjek, Karl; Mogk, Jeremy P M; Agur, Anne M R
2018-03-23
Altered three-dimensional (3D) joint kinematics can contribute to shoulder pathology, including post-stroke shoulder pain. Reliable assessment methods enable comparative studies between asymptomatic shoulders of healthy subjects and painful shoulders of post-stroke subjects, and could inform treatment planning for post-stroke shoulder pain. The study purpose was to establish intra-rater test-retest reliability and within-subject repeatability of a palpation/digitization protocol, which assesses 3D clavicular/scapular/humeral rotations, in asymptomatic and painful post-stroke shoulders. Repeated measurements of 3D clavicular/scapular/humeral joint/segment rotations were obtained using palpation/digitization in 32 asymptomatic and six painful post-stroke shoulders during four reaching postures (rest/flexion/abduction/external rotation). Intra-class correlation coefficients (ICCs), standard error of the measurement and 95% confidence intervals were calculated. All ICC values indicated high to very high test-retest reliability (≥0.70), with lower reliability for scapular anterior/posterior tilt during external rotation in asymptomatic subjects, and scapular medial/lateral rotation, humeral horizontal abduction/adduction and axial rotation during abduction in post-stroke subjects. All standard error of measurement values demonstrated within-subject repeatability error ≤5° for all clavicular/scapular/humeral joint/segment rotations (asymptomatic ≤3.75°; post-stroke ≤5.0°), except for humeral axial rotation (asymptomatic ≤5°; post-stroke ≤15°). This noninvasive, clinically feasible palpation/digitization protocol was reliable and repeatable in asymptomatic shoulders, and in a smaller sample of painful post-stroke shoulders. Implications for Rehabilitation In the clinical setting, a reliable and repeatable noninvasive method for assessment of three-dimensional (3D) clavicular/scapular/humeral joint orientation and range of motion (ROM) is currently required. The established reliability and repeatability of this proposed palpation/digitization protocol will enable comparative 3D ROM studies between asymptomatic and post-stroke shoulders, which will further inform treatment planning. Intra-rater test-retest repeatability, which is measured by the standard error of the measure, indicates the range of error associated with a single test measure. Therefore, clinicians can use the standard error of the measure to determine the "true" differences between pre-treatment and post-treatment test scores.
Kinematic repeatability of a multi-segment foot model for dance.
Carter, Sarah L; Sato, Nahoko; Hopper, Luke S
2018-03-01
The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.
Daniels, Sarah I; Sillé, Fenna C M; Goldbaum, Audrey; Yee, Brenda; Key, Ellen F; Zhang, Luoping; Smith, Martyn T; Thomas, Reuben
2014-12-01
Blood miRNAs are a new promising area of disease research, but variability in miRNA measurements may limit detection of true-positive findings. Here, we measured sources of miRNA variability and determine whether repeated measures can improve power to detect fold-change differences between comparison groups. Blood from healthy volunteers (N = 12) was collected at three time points. The miRNAs were extracted by a method predetermined to give the highest miRNA yield. Nine different miRNAs were quantified using different qPCR assays and analyzed using mixed models to identify sources of variability. A larger number of miRNAs from a publicly available blood miRNA microarray dataset with repeated measures were used for a bootstrapping procedure to investigate effects of repeated measures on power to detect fold changes in miRNA expression for a theoretical case-control study. Technical variability in qPCR replicates was identified as a significant source of variability (P < 0.05) for all nine miRNAs tested. Variability was larger in the TaqMan qPCR assays (SD = 0.15-0.61) versus the qScript qPCR assays (SD = 0.08-0.14). Inter- and intraindividual and extraction variability also contributed significantly for two miRNAs. The bootstrapping procedure demonstrated that repeated measures (20%-50% of N) increased detection of a 2-fold change for approximately 10% to 45% more miRNAs. Statistical power to detect small fold changes in blood miRNAs can be improved by accounting for sources of variability using repeated measures and choosing appropriate methods to minimize variability in miRNA quantification. This study demonstrates the importance of including repeated measures in experimental designs for blood miRNA research. See all the articles in this CEBP Focus section, "Biomarkers, Biospecimens, and New Technologies in Molecular Epidemiology." ©2014 American Association for Cancer Research.
Van Hemelrijck, Mieke; Holmberg, Lars; Garmo, Hans; Hammar, Niklas; Walldius, Göran; Binda, Elisa; Lambe, Mats; Jungner, Ingmar
2011-01-01
Objective To study levels of C-reactive protein (CRP) and leukocytes, as inflammatory markers, in the context of cancer risk. Methods From the Apolipoprotein MOrtality RISk (AMORIS) study, we selected 102,749 persons with one measurement and 9,273 persons with three repeated measurements of CRP and leukocytes. Multivariate Cox proportional hazards regression was applied to categories of CRP (<10, 10-15, 15-25, 25-50, >50 g/L) and quartiles of leukocytes. An Inflammation-based Predictive Score (IPS) indicated whether someone had CRP levels >10mg/L combined with leukocytes >10×109/L. Reverse causality was assessed by excluding those with <3, 5, or 7 years of follow-up. To analyze repeated measurements of CRP and leukocytes the repeated IPS (IPSr) was calculated by adding the IPS of each measurement. Results In the cohort with one measurement, there was a positive trend between CRP and cancer, with the lowest category being the reference: 0.99 (0.92-1.06), 1.28 (1.11-1.47), 1.27 (1.09-1.49), 1.22 (1.01-1.48) for the 2nd to 5th categories, respectively. This association disappeared when excluding those with follow-up <3, 5 or 7 years. The association between leukocytes and cancer was slightly stronger. In the cohort with repeated measurements the IPSr was strongly associated with cancer risk: 1.87 (1.33-2.63), 1.51 (0.56-4.06), 4.46 (1.43-13.87) for IPSr =1, 2, and 3, compared to IPSr =0. The association remained after excluding those with follow-up <1 year. Conclusions and impact Our large prospective cohort study adds evidence for a link between inflammatory markers and cancer risk by using repeated measurements and ascertaining reverse causality. PMID:21297038
Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham
2017-01-01
Purpose This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. Materials and Methods A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. Conclusion The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients. PMID:29279822
Su, Ning; Zhai, Fei-Fei; Zhou, Li-Xin; Ni, Jun; Yao, Ming; Li, Ming-Li; Jin, Zheng-Yu; Gong, Gao-Lang; Zhang, Shu-Yang; Cui, Li-Ying; Tian, Feng; Zhu, Yi-Cheng
2017-01-01
Objective: To investigate the correlation between cerebral small vessel disease (CSVD) burden and motor performance of lower and upper extremities in community-dwelling populations. Methods: We performed a cross-sectional analysis on 770 participants enrolled in the Shunyi study, which is a population-based cohort study. CSVD burden, including white matter hyperintensities (WMH), lacunes, cerebral microbleeds (CMBs), perivascular spaces (PVS), and brain atrophy were measured using 3T magnetic resonance imaging. All participants underwent quantitative motor assessment of lower and upper extremities, which included 3-m walking speed, 5-repeat chair-stand time, 10-repeat pronation–supination time, and 10-repeat finger-tapping time. Data on demographic characteristics, vascular risk factors, and cognitive functions were collected. General linear model analysis was performed to identify potential correlations between motor performance measures and imaging markers of CSVD after controlling for confounding factors. Results: For motor performance of the lower extremities, WMH was negatively associated with gait speed (standardized β = -0.092, p = 0.022) and positively associated with chair-stand time (standardized β = 0.153, p < 0.0001, surviving FDR correction). For motor performance of the upper extremities, pronation–supination time was positively associated with WMH (standardized β = 0.155, p < 0.0001, surviving FDR correction) and negatively with brain parenchymal fraction (BPF; standardized β = -0.125, p = 0.011, surviving FDR correction). Only BPF was found to be negatively associated with finger-tapping time (standardized β = -0.123, p = 0.012). However, lacunes, CMBs, or PVS were not found to be associated with motor performance of lower or upper extremities in multivariable analysis. Conclusion: Our findings suggest that cerebral microstructural changes related to CSVD may affect motor performance of both lower and upper extremities. WMH and brain atrophy are most strongly associated with motor function deterioration in community-dwelling populations. PMID:29021757
Su, Ning; Zhai, Fei-Fei; Zhou, Li-Xin; Ni, Jun; Yao, Ming; Li, Ming-Li; Jin, Zheng-Yu; Gong, Gao-Lang; Zhang, Shu-Yang; Cui, Li-Ying; Tian, Feng; Zhu, Yi-Cheng
2017-01-01
Objective: To investigate the correlation between cerebral small vessel disease (CSVD) burden and motor performance of lower and upper extremities in community-dwelling populations. Methods: We performed a cross-sectional analysis on 770 participants enrolled in the Shunyi study, which is a population-based cohort study. CSVD burden, including white matter hyperintensities (WMH), lacunes, cerebral microbleeds (CMBs), perivascular spaces (PVS), and brain atrophy were measured using 3T magnetic resonance imaging. All participants underwent quantitative motor assessment of lower and upper extremities, which included 3-m walking speed, 5-repeat chair-stand time, 10-repeat pronation-supination time, and 10-repeat finger-tapping time. Data on demographic characteristics, vascular risk factors, and cognitive functions were collected. General linear model analysis was performed to identify potential correlations between motor performance measures and imaging markers of CSVD after controlling for confounding factors. Results: For motor performance of the lower extremities, WMH was negatively associated with gait speed (standardized β = -0.092, p = 0.022) and positively associated with chair-stand time (standardized β = 0.153, p < 0.0001, surviving FDR correction). For motor performance of the upper extremities, pronation-supination time was positively associated with WMH (standardized β = 0.155, p < 0.0001, surviving FDR correction) and negatively with brain parenchymal fraction (BPF; standardized β = -0.125, p = 0.011, surviving FDR correction). Only BPF was found to be negatively associated with finger-tapping time (standardized β = -0.123, p = 0.012). However, lacunes, CMBs, or PVS were not found to be associated with motor performance of lower or upper extremities in multivariable analysis. Conclusion: Our findings suggest that cerebral microstructural changes related to CSVD may affect motor performance of both lower and upper extremities. WMH and brain atrophy are most strongly associated with motor function deterioration in community-dwelling populations.
NASA Astrophysics Data System (ADS)
Sakai, Takamasa; Kohno, Motohiro; Hirae, Sadao; Nakatani, Ikuyoshi; Kusuda, Tatsufumi
1993-09-01
In this paper, we discussed a novel approach to semiconductor surface inspection, which is analysis using the C--V curve measured in a noncontact method by the metal-air-semiconductor (MAIS) technique. A new gap sensing method using the so-called Goos-Haenchen effect was developed to achieve the noncontact C--V measurement. The MAIS technique exhibited comparable sensitivity and repeatability to those of conventional C--V measurement, and hence, good reproducibility and resolution for quantifying the electrically active impurity on the order of 1× 109/cm2, which is better than most spectrometric techniques, such as secondary ion mass spectroscopy (SIMS), electron spectroscopy for chemical analysis (ESCA) and Auger electron spectrocopy (AES) which are time-consuming and destructive. This measurement without preparation of any electrical contact metal electrode suggested, for the first time, the possibility of measuring an intrinsic characteristic of the semiconductor surface, using the examples of a concrete examination.
Cashman, P M M; Baring, T; Reilly, P; Emery, R J H; Amis, A A
2010-04-01
The purpose of this study was to develop a technique to use Roentgen stereophotogrammetric analysis (RSA) to measure migration of soft-tissue structures after rotator cuff repair. RSA stereo films were obtained; images were analysed using a semi-automatic software program allowing 3D viewing of results. RSA imaging experiments were performed to validate the technique, using a glass phantom with implanted RSA beads and an animal model with steel sutures as RSA markers which were moved known distances. Repeated measurements allowed assessment of inter- and intra-observer variability at a maximum of 1.06 mm. RSA analysis of the phantom showed a variation up to 0.22 mm for static and 0.28 mm for dynamic studies. The ovine tissue specimen demonstrated that using steel sutures as RSA markers in soft tissue is feasible, although less accurate than when measuring bone motion. This novel application of RSA to measure soft tissue migration is practicable and can be extended to in vivo studies.
Tirabassi, G; delli Muti, N; Gioia, A; Biagioli, A; Lenzi, A; Balercia, G
2014-04-01
The relationship between androgen receptor (AR) CAG polymorphism and bone metabolism is highly controversial. We, therefore, aimed to evaluate the independent role of AR CAG repeat polymorphism on bone metabolism improvement induced by testosterone replacement therapy (TRT) in male post-surgical hypogonadotropic hypogonadism, a condition frequently associated with hypopituitarism and in which the effects of TRT have to be distinguished from those resulting from concomitant administration of pituitary function replacing hormones. 12 men affected by post-surgical hypogonadotropic hypogonadism [mean duration of hypogonadism 8.3 ± 2.05 (SD) months] were retrospectively assessed before and after TRT (from 74 to 84 weeks after the beginning of therapy). The following measures were studied: parameters of bone metabolism [serum markers and bone mineral density (BMD)], pituitary dependent hormones and genetic analysis (AR CAG repeat number). Total testosterone, estradiol, free T4 (FT4) and insulin-like growth factor-1 (IGF-1) increased between the two phases, while follicle stimulating hormone (FSH) decreased. While serum markers did not vary significantly between the two phases, BMD improved slightly but significantly in all the studied sites. The number of CAG triplets correlated negatively and significantly with all the variations (Δ-) of BMDs. Conversely, Δ-testosterone correlated positively and significantly with all studied Δ-BMDs, while Δ-FSH, Δ-estradiol, Δ-FT4, and Δ-IGF-1 did not correlate significantly with any of the Δ-BMDs. Multiple linear regression analysis, after correction for Δ-testosterone, showed that CAG repeat length was negatively and significantly associated with ∆-BMD of all measured sites. Our data suggest that, in post-surgical male hypogonadotropic hypogonadism, shorter AR CAG tract is independently associated with greater TRT-induced improvement of BMD.
SU-E-J-26: Analysis of Image Quality in CBCT QA Using a Treatment Planning System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, M
2014-06-01
Purpose: The objective of this study is to propose an alternative QA technique that analyzes imaging quality(IQ) in CBCT-QA processing. Methods: A catphan phantom was used to take CT imaging data set that were imported into a treatment planning system - Eclipse. The image quality was analyzed in terms of in-slice geometry resolution, Hounsfield numbers(HU) accuracy, mean-slice thickness, edge-to-center uniformity, low contrast resolution, and high contrast spatial resolution in Eclipse workstation. The CBCT-QA was also analyzed by OBI-workstation and a commercial software. Comparison was made to evaluation feasibility in a TPS environment. Results: The analysis of IQ was conducted inmore » Eclipse v10.0 TPS. In-slice geometric resolution was measured between 2-rods in section CTP404 and repeated for all 4 rods with the difference between expected and measured values less than +/−0.1 cm. For HU, the difference between expected and measured values in HU was found much less than +/−40. Mean slice thickness measured by a distance on the wire proportional to scanner increment multiplying by a factor of 0.42. After repeating measurements to 4 wires, the average difference between expected and measured values was less +/−0.124 mm in slice thickness. HU uniformity was measured in section CTP486 with the tolerance less than +/−40 HU. Low contrast resolution in section CTP515 and high contrast resolution in section CTP528 were found to be 7 disks in diameter of 4 mm and 6 lp/cm, respectively. Eclipse TPS results indicated a good agreement to those obtained in OBI workstation and ImagePro software for major parameters. Conclusion: An analysis of IQ was proposed as an alternative CBCT QA processing. Based upon measured data assessment, proposed method was accurate and consistent to IQ evaluation and TG142 guideline. The approach was to utilize TPS resource, which can be valuable to re-planning, verification, and delivery in adaptive therapy.« less
Effect of Repeat Copy Number on Variable-Number Tandem Repeat Mutations in Escherichia coli O157:H7
Vogler, Amy J.; Keys, Christine; Nemoto, Yoshimi; Colman, Rebecca E.; Jay, Zack; Keim, Paul
2006-01-01
Variable-number tandem repeat (VNTR) loci have shown a remarkable ability to discriminate among isolates of the recently emerged clonal pathogen Escherichia coli O157:H7, making them a very useful molecular epidemiological tool. However, little is known about the rates at which these sequences mutate, the factors that affect mutation rates, or the mechanisms by which mutations occur at these loci. Here, we measure mutation rates for 28 VNTR loci and investigate the effects of repeat copy number and mismatch repair on mutation rate using in vitro-generated populations for 10 E. coli O157:H7 strains. We find single-locus rates as high as 7.0 × 10−4 mutations/generation and a combined 28-locus rate of 6.4 × 10−4 mutations/generation. We observed single- and multirepeat mutations that were consistent with a slipped-strand mispairing mutation model, as well as a smaller number of large repeat copy number mutations that were consistent with recombination-mediated events. Repeat copy number within an array was strongly correlated with mutation rate both at the most mutable locus, O157-10 (r2 = 0.565, P = 0.0196), and across all mutating loci. The combined locus model was significant whether locus O157-10 was included (r2 = 0.833, P < 0.0001) or excluded (r2 = 0.452, P < 0.0001) from the analysis. Deficient mismatch repair did not affect mutation rate at any of the 28 VNTRs with repeat unit sizes of >5 bp, although a poly(G) homomeric tract was destabilized in the mutS strain. Finally, we describe a general model for VNTR mutations that encompasses insertions and deletions, single- and multiple-repeat mutations, and their relative frequencies based upon our empirical mutation rate data. PMID:16740932
Voice measures of workload in the advanced flight deck
NASA Technical Reports Server (NTRS)
Schneider, Sid J.; Alpert, Murray; Odonnell, Richard
1989-01-01
Voice samples were obtained from 14 male subjects under high and low workload conditions. Acoustical analysis of the voice suggested that high workload conditions can be revealed by their effects on the voice over time. Aircrews in the advanced flight deck will be voicing short, imperative sentences repeatedly. A drop in the energy of the voice, as reflected by reductions in amplitude and frequency over time, and the failure to achieve old amplitude and frequency levels after rest periods, can signal that the workload demands of the situation are straining the speaker. This kind of measurement would be relatively unaffected by individual differences in acoustical measures.
Micromechanics Fatigue Damage Analysis Modeling for Fabric Reinforced Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Min, J. B.; Xue, D.; Shi, Y.
2013-01-01
A micromechanics analysis modeling method was developed to analyze the damage progression and fatigue failure of fabric reinforced composite structures, especially for the brittle ceramic matrix material composites. A repeating unit cell concept of fabric reinforced composites was used to represent the global composite structure. The thermal and mechanical properties of the repeating unit cell were considered as the same as those of the global composite structure. The three-phase micromechanics, the shear-lag, and the continuum fracture mechanics models were integrated with a statistical model in the repeating unit cell to predict the progressive damages and fatigue life of the composite structures. The global structure failure was defined as the loss of loading capability of the repeating unit cell, which depends on the stiffness reduction due to material slice failures and nonlinear material properties in the repeating unit cell. The present methodology is demonstrated with the analysis results evaluated through the experimental test performed with carbon fiber reinforced silicon carbide matrix plain weave composite specimens.
Acharya, Shruthi; Pai, Keerthilatha M.; Acharya, Shashidhar
2015-01-01
Context: The goal of any radiologist is to produce the highest quality diagnostic radiographs, while keeping patient exposure as low as reasonably achievable (ALARA). Aims: The aim of this study was to describe the reasons for radiograph rejections through a repeat film analysis in an Indian dental school. Settings and Design: An observational study conducted in the Department of Oral Medicine and Radiology, Manipal College of Dental Sciences, Manipal. Materials and Methods: During a 6-month study period, a total of 9,495 intra-oral radiographs and 2339 extraoral radiographs taken in the Radiology Department were subjected to repeat film analysis. Statistical Analysis Used: SPSS Version 16. Descriptive analysis used. Results: The results showed that the repeat rates were 7.1% and 5.86% for intraoral and extraoral radiographs, respectively. Among the causes for errors reported, positioning error (38.7%) was the most common, followed by improper angulations (26.1%), and improper film placement (11.2%) for intra-oral radiographs. The study found that the maximum frequency of repeats among extraoral radiographs was for panoramic radiographs (49%) followed by lateral cephalogram (33%), and paranasal sinus view (14%). It was also observed that repeat rate of intraoral radiographs was highest for internees (44.7%), and undergraduate students (28.2%). Conclusions: The study pointed to a need for more targeted interventions to achieve the goal of keeping patient exposure ALARA in a dental school setting. PMID:26321841
Feng, Yong; Chen, Aiqing
2017-01-01
This study aimed to quantify blood pressure (BP) measurement accuracy and variability with different techniques. Thirty video clips of BP recordings from the BHS training database were converted to Korotkoff sound waveforms. Ten observers without receiving medical training were asked to determine BPs using (a) traditional manual auscultatory method and (b) visual auscultation method by visualizing the Korotkoff sound waveform, which was repeated three times on different days. The measurement error was calculated against the reference answers, and the measurement variability was calculated from the SD of the three repeats. Statistical analysis showed that, in comparison with the auscultatory method, visual method significantly reduced overall variability from 2.2 to 1.1 mmHg for SBP and from 1.9 to 0.9 mmHg for DBP (both p < 0.001). It also showed that BP measurement errors were significant for both techniques (all p < 0.01, except DBP from the traditional method). Although significant, the overall mean errors were small (−1.5 and −1.2 mmHg for SBP and −0.7 and 2.6 mmHg for DBP, resp., from the traditional auscultatory and visual auscultation methods). In conclusion, the visual auscultation method had the ability to achieve an acceptable degree of BP measurement accuracy, with smaller variability in comparison with the traditional auscultatory method. PMID:29423405
Urbinello, Damiano; Huss, Anke; Beekhuizen, Johan; Vermeulen, Roel; Röösli, Martin
2014-01-15
Radiofrequency electromagnetic fields (RF-EMF) are highly variable and differ considerably within as well as between areas. Exposure assessment studies characterizing spatial and temporal variation are limited so far. Our objective was to evaluate sources of data variability and the repeatability of daily measurements using portable exposure meters (PEMs). Data were collected at 12 days between November 2010 and January 2011 with PEMs in four different types of urban areas in the cities of Basel (BSL) and Amsterdam (AMS). Exposure from mobile phone base stations ranged from 0.30 to 0.53 V/m in downtown and business areas and in residential areas from 0.09 to 0.41 V/m. Analysis of variance (ANOVA) demonstrated that measurements from various days were highly reproducible (measurement duration of approximately 30 min) with only 0.6% of the variance of all measurements from mobile phone base station radiation being explained by the measurement day and only 0.2% by the measurement time (morning, noon, afternoon), whereas type of area (30%) and city (50%) explained most of the data variability. We conclude that mobile monitoring of exposure from mobile phone base station radiation with PEMs is useful due to the high repeatability of mobile phone base station exposure levels, despite the high spatial variation. © 2013.
Pre-Test Assessment of the Upper Bound of the Drag Coefficient Repeatability of a Wind Tunnel Model
NASA Technical Reports Server (NTRS)
Ulbrich, N.; L'Esperance, A.
2017-01-01
A new method is presented that computes a pre{test estimate of the upper bound of the drag coefficient repeatability of a wind tunnel model. This upper bound is a conservative estimate of the precision error of the drag coefficient. For clarity, precision error contributions associated with the measurement of the dynamic pressure are analyzed separately from those that are associated with the measurement of the aerodynamic loads. The upper bound is computed by using information about the model, the tunnel conditions, and the balance in combination with an estimate of the expected output variations as input. The model information consists of the reference area and an assumed angle of attack. The tunnel conditions are described by the Mach number and the total pressure or unit Reynolds number. The balance inputs are the partial derivatives of the axial and normal force with respect to all balance outputs. Finally, an empirical output variation of 1.0 microV/V is used to relate both random instrumentation and angle measurement errors to the precision error of the drag coefficient. Results of the analysis are reported by plotting the upper bound of the precision error versus the tunnel conditions. The analysis shows that the influence of the dynamic pressure measurement error on the precision error of the drag coefficient is often small when compared with the influence of errors that are associated with the load measurements. Consequently, the sensitivities of the axial and normal force gages of the balance have a significant influence on the overall magnitude of the drag coefficient's precision error. Therefore, results of the error analysis can be used for balance selection purposes as the drag prediction characteristics of balances of similar size and capacities can objectively be compared. Data from two wind tunnel models and three balances are used to illustrate the assessment of the precision error of the drag coefficient.
Pathological Fingerprints, Systems Biology and Biomarkers of Blast Brain Injury
2010-06-01
in triplicate. *=pɘ.05 vs. sham ( noise exposed rats) according unpaired t-test analysis. NS- Not significant. E-selectin and L-selectin are adhesion...an energy balance, food intake, wakefulness . We measured serum Resistin and Orexin A levels after blast exposure using 2 different methods...penetrating flesh wounds (Belanger et al., 2005; Lew, 2005). However, even mild and moderate brain injuries can produce significant deficits , and when repeated
ERIC Educational Resources Information Center
Hsieh, Chueh-An; von Eye, Alexander A.; Maier, Kimberly S.
2010-01-01
The application of multidimensional item response theory models to repeated observations has demonstrated great promise in developmental research. It allows researchers to take into consideration both the characteristics of item response and measurement error in longitudinal trajectory analysis, which improves the reliability and validity of the…
2010-01-01
Seemingly not . Repeated measures analysis of variance (ANOVA) for posttest - pretest score gain x training product interaction yielded a non-significant...Code 15. Supplemental Notes Work was accomplished under approved task AM-A-07-HRR-521 16. Abstract This research has two main...1 Purpose of This Research
Officer Career Development: An Overview of Analytic Concerns
1989-07-01
some form of quasi-experimental analysis with nonequivalent control groups may be implemented. We shall not attempt to explic te all the variables...Development Center. 5. University of San Diego (1984, October 23-25). Pro z.ings: Volume I. Group reports. Tri-service career research workshop. San Die... design rather than a repeated measures design , where differences among diverse groups of different individuals (at different career stages) are used to
ERIC Educational Resources Information Center
Mills, Caroline; Chapparo, Christine
2017-01-01
The aim of this study was to determine the impact of a classroom sensory activity schedule (SAS) on cognitive strategy use during task performance. This work studies a single-system AB research design with seven students with autism and intellectual disability. Repeated measures using the Perceive, Recall, Plan and Perform (PRPP) Cognitive Task…
Dual-Valve and Counter-Flow Surface Plasmon Resonance.
Wang, Xiaoying; Zhou, Feimeng
2018-04-17
Two six-port injector valves and one selector valve commonly used in flow injection analysis are combined with a surface plasmon resonance (SPR) instrument wherein solutions introduced from the two inlets counter-flow inside the flow cell. The system is versatile as the same or different solutions can be rapidly and repeatedly introduced to the two fluidic channels in series or in parallel. Unlike most commercial SPR instruments employing a single injector valve, solutions separately injected from the two injector valves can be readily exchanged (<1 s) between the two channels. This new method, referred to as the alternate injection mode, not only saves analysis time but also facilitates efficient and facile surface reactions for ligand immobilization and prevents immobilized species from desorbing. These advantages are demonstrated with the measurements of binding of acetazolamide (222.2 Da) to histidine-tagged human carbonic anhydrase II (his-tagged HCA). Amine-containing residues of his-tagged HCA molecules tethered at Ni-nitrilotriacetic acid (NTA) sensors were rapidly cross-linked to the underlying carboxymethylated dextran. The higher ligand densities and more stable surfaces are essential for SPR detection of small molecule binding. In a different application, microglobulin solutions of increasing concentrations were introduced for continuous binding to the preimmobilized antibody. The kinetic and affinity measurements can be conducted without performing repeated dissociation and surface regeneration reactions.
Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan
2005-07-01
Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.
Decoster, Laura C; Burns, Matthew F; Swartz, Erik E; Murthi, Dinakar S; Hernandez, Adam E; Vailas, James C; Isham, Linda L
2012-04-15
Descriptive laboratory study. To determine whether the placement of padding beneath the occiput after helmet removal is an effective intervention to maintain neutral sagittal cervical spine alignment in a position comparable with the helmeted condition. Current on-field recommendations for managing football athletes with suspected cervical spine injuries call for face mask removal, rather than helmet removal, because the combination of helmet and shoulder pads has been shown to maintain neutral cervical alignment. Therefore, in cases when helmet removal is required, recommendations also call for shoulder pad removal. Because removal of equipment causes motion, any technique that postpones the need to remove the shoulder pads would reduce prehospital motion. Four lateral radiographs of 20 male participants were obtained (age = 23.6 ± 2.7 years). Radiographs of participants wearing shoulder pads and helmet were first obtained. The helmet was removed and radiographs of participants with occipital padding were obtained immediately and 20 minutes later and finally without occipital padding. Cobb angle measurements for C2-C6 vertebral segments were determined by an orthopedic spine surgeon blinded to the study's purpose. Intraobserver reliability was determined using intraclass coefficient analysis. Measurements were analyzed using a 1×4 repeated-measures analysis of variance and post hoc pairwise comparisons with Bonferroni correction. Intraobserver analysis showed excellent reliability (intraclass correlation = 1.0; 95% confidence interval [CI], 0.999-1.0). Repeated-measures analysis of variance detected significant differences (F(3,17) = 13.34; P < 0.001). Pairwise comparisons revealed no differences in cervical alignment (all measurements reported reflect lordosis) when comparing the baseline helmeted condition (10.1° ± 8.7°; 95% CI, 6.0-14.1) with the padded conditions. Measurements taken after removal of occipital padding (14.4° ± 8.1°; 95% CI, 10.6-18.2) demonstrated a significant increase in cervical lordosis compared with the immediate padded measurement (9.5° ± 6.9°; 95% CI, 6.3-12.7; P = 0.011) and the 20-minute padded measurement (6.5° ± 6.8°; 95% CI, 3.4-9.7; P < 0.001). Although face mask removal remains the standard, if it becomes necessary to remove the football helmet in the field, occipital padding (along with full body/head immobilization techniques) may be used to limit cervical lordosis, allowing safe delay of shoulder pad removal.
High-precision radius automatic measurement using laser differential confocal technology
NASA Astrophysics Data System (ADS)
Jiang, Hongwei; Zhao, Weiqian; Yang, Jiamiao; Guo, Yongkui; Xiao, Yang
2015-02-01
A high precision radius automatic measurement method using laser differential confocal technology is proposed. Based on the property of an axial intensity curve that the null point precisely corresponds to the focus of the objective and the bipolar property, the method uses the composite PID (proportional-integral-derivative) control to ensure the steady movement of the motor for process of quick-trigger scanning, and uses least-squares linear fitting to obtain the position of the cat-eye and confocal positions, then calculates the radius of curvature of lens. By setting the number of measure times, precision auto-repeat measurement of the radius of curvature is achieved. The experiment indicates that the method has the measurement accuracy of better than 2 ppm, and the measuring repeatability is better than 0.05 μm. In comparison with the existing manual-single measurement, this method has a high measurement precision, a strong environment anti-interference capability, a better measuring repeatability which is only tenth of former's.
An overview of longitudinal data analysis methods for neurological research.
Locascio, Joseph J; Atri, Alireza
2011-01-01
The purpose of this article is to provide a concise, broad and readily accessible overview of longitudinal data analysis methods, aimed to be a practical guide for clinical investigators in neurology. In general, we advise that older, traditional methods, including (1) simple regression of the dependent variable on a time measure, (2) analyzing a single summary subject level number that indexes changes for each subject and (3) a general linear model approach with a fixed-subject effect, should be reserved for quick, simple or preliminary analyses. We advocate the general use of mixed-random and fixed-effect regression models for analyses of most longitudinal clinical studies. Under restrictive situations or to provide validation, we recommend: (1) repeated-measure analysis of covariance (ANCOVA), (2) ANCOVA for two time points, (3) generalized estimating equations and (4) latent growth curve/structural equation models.
Protocol for statistical analysis of vegetation changes at Catoctin Mountain Park
Hatfield, Jeff S.; Krafft, Cairn
2010-01-01
Vegetation data collected at Catoctin Mountain Park, Maryland, in a split-panel rotation design during 2004-2009 were analyzed for differences among three regions within the park and among years. Six plots were paired with plots fenced to exclude white-tailed deer (Odocoileus virginianus), and differences between open and exclosed plots were also investigated. Repeated measures analysis of variance (ANOVA) was used to test for differences in the following variables: percentage of twigs browsed, percentage of canopy cover, and number of tree and shrub seedlings in each of five height classes. Except for some differences in numbers of tree and shrub seedlings among height classes among the regions, no differences (P > 0.05) were found among the regions or over time in the variables measured. Recommendations for future sampling and analysis are discussed.
Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord
2012-09-01
The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.
Rao, Harsha L; Venkatesh, Chirravuri R; Vidyasagar, Kelli; Yadav, Ravi K; Addepalli, Uday K; Jude, Aarthi; Senthil, Sirisha; Garudadri, Chandra S
2014-12-01
To evaluate the (i) effects of biological (age and axial length) and instrument-related [typical scan score (TSS) and corneal birefringence] parameters on the retinal nerve fiber layer (RNFL) measurements and (ii) repeatability of RNFL measurements with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in healthy subjects. In a cross-sectional study, 140 eyes of 73 healthy subjects underwent RNFL imaging with the ECC protocol of SLP. Linear mixed modeling methods were used to evaluate the effects of age, axial length, TSS, and corneal birefringence on RNFL measurements. One randomly selected eye of 48 subjects from the cohort underwent 3 serial scans during the same session to determine the repeatability. Age significantly influenced all RNFL measurements. RNFL measurements decreased by 1 µm for every decade increase in age. TSS affected the overall average RNFL measurement (β=-0.62, P=0.003), whereas residual anterior segment retardance affected the superior quadrant measurement (β=1.14, P=0.01). Axial length and corneal birefringence measurements did not influence RNFL measurements. Repeatability, as assessed by the coefficient of variation, ranged between 1.7% for the overall average RNFL measurement and 11.4% for th nerve fiber indicator. Age significantly affected all RNFL measurements with the ECC protocol of SLP, whereas TSS and residual anterior segment retardance affected the overall average and the superior average RNFL measurements, respectively. Axial length and corneal birefringence measurements did not influence any RNFL measurements. RNFL measurements had good intrasession repeatability. These results are important while evaluating the change in structural measurements over time in glaucoma patients.
Flow-injection analysis of catecholamine secretion from bovine adrenal medulla cells on microbeads.
Herrera, M; Kao, L S; Curran, D J; Westhead, E W
1985-01-01
Bovine adrenal medullary cells have been cultured on microbeads which are placed in a low-volume flow system for measurements of stimulation-response parameters. Electronically controlled stream switching allows stimulation of cells with pulse lengths from 1 s to many minutes; pulses may be repeated indefinitely. Catecholamines secreted are detected by an electrochemical detector downstream from the cells. This flow-injection analysis technique provides a new level of sensitivity and precision for measurement of kinetic parameters of secretion. A manual injection valve allows stimulation by higher levels of stimulant in the presence of constant low levels of stimulant. Such experiments show interesting differences between the effects of K+ and acetylcholine on cells partially desensitized to acetylcholine.
Endre, Zoltán H; Pianta, Timothy J; Pickering, John W
2016-01-01
Post transplant repeated measurements of urine volume and serum creatinine (sCr) are used to assess kidney function. Under non-steady state conditions, repeated measurement of sCr allows calculation of the kinetic estimated GFR (KeGFR). Additional measurement of urinary creatinine allows the calculation of the creatinine excretion to (estimated) production ratio (E/eG). We hypothesized that post-transplant KeGFR and E/eG would predict delayed graft function (DGF), as early as 4 h and outperform a validated clinical model at 12 h. This was a retrospective analysis of prospectively acquired data in a study of 56 recipients of deceased-donor kidney transplant. We assessed predictive performance with the area under the receiver operator characteristic curve (AUC) and the added value to a clinical model with integrated discrimination improvement analysis. At 4 h, the AUC for E/eG was 0.87 (95% CI 0.77-0.96) and for KeGFR 0.69 (95% CI 0.56-0.83). Both E/eG and KeGFR improved the risk prediction of a clinical model for DGF by 32 and 18%, and for non-DGF by 17 and 10%, respectively. While E/eG had better predictive performance of DGF than KeGFR, KeGFR might also facilitate perioperative management including drug dosing after kidney transplantation. Together these measurements may facilitate the possibility of conducting trials of early intervention to ameliorate the adverse effects of ischaemia-reperfusion injury on long-term DGF. © 2016 S. Karger AG, Basel.
Brozović, Juraj; Demoli, Nazif; Farkaš, Nina; Sušić, Mato; Alar, Zeljko; Gabrić Pandurić, Dragana
2014-03-01
The aim of this study was to (i) obtain the force-related interferometric patterns of loaded dental implant-abutment assemblies differing in diameter and brand using digital holographic interferometry (DHI) and (ii) determine the influence of implant diameter on the extent of load-induced implant deformation by quantifying and comparing the obtained interferometric data. Experiments included five implant brands (Ankylos, Astra Tech, blueSKY, MIS and Straumann), each represented by a narrow and a wide diameter implant connected to a corresponding abutment. A quasi-Fourier setup with a 25mW helium-neon laser was used for interferometric measurements in the cervical 5mm of the implants. Holograms were recorded in two conditions per measurement: a 10N preloaded and a measuring-force loaded assembly, resulting with an interferogram. This procedure was repeated throughout the whole process of incremental axial loading, from 20N to 120N. Each measurement series was repeated three times for each assembly, with complete dismantling of the implant-loading device in between. Additional software analyses calculated deformation data. Deformations were presented as mean values±standard deviations. Statistical analysis was performed using linear mixed effects modeling in R's lme4 package. Implants exhibited linear deformation patterns. The wide diameter group had lower mean deformation values than the narrow diameter group. The diameter significantly affected the deformation throughout loading sessions. This study gained in vitro implant performance data, compared the deformations in implant bodies and numerically stated the biomechanical benefits of wider diameter implants. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Lamoureux, Nicholas R; Tomkinson, Grant R; Peterson, Benjamin J; Fitzgerald, John S
2018-04-01
Lamoureux, NR, Tomkinson, GR, Peterson, BJ, and Fitzgerald, JS. Relationship between skating economy and performance during a repeated-shift test in elite and subelite ice hockey players. J Strength Cond Res 32(4): 1109-1113, 2018-The purpose of this study was to determine the importance of skating economy to fatigue during repeated high-intensity efforts of a simulated ice hockey shift. Forty-five collegiate and Junior A male ice hockey players (aged 18-24 years) performed a continuous graded exercise test using a skate treadmill. Breath-by-breath data for oxygen consumption (V[Combining Dot Above]O2) and respiratory exchange ratio were collected and used to derive energy expenditure (EE) averaged over the final 10 seconds of each stage. Economy was determined as the slope of the regression line relating V[Combining Dot Above]O2 and EE against skating speed separately. Participants also completed 8 bouts of maximal ice skating through a course designed to simulate typical shift, with timing gates determining first half, second half, and total fatigue decrement, calculated by a percent decrement score. Partial correlation was used to determine the association between economy measures and decrement during the repeated-shift test. Twenty-six participants met inclusion criteria and were included in data analysis. Skating economy measures (both relative V[Combining Dot Above]O2 and EE) were very likely moderate positive correlates of total fatigue decrement (r [95% confidence interval]: V[Combining Dot Above]O2, 0.46 [0.09, 0.72] and EE, 0.44, [0.06, 0.71]) but not with first or second gate decrement. Our results indicate that skating economy plays an important role in fatigue resistance over repeated on-ice sprints designed to simulate a typical shift. This supports the use of technical skating coaching and training techniques to enhance skating economy as a means of improving ice hockey performance.
Kuo, Hann-Chorng
2013-01-01
Onabotulinumtoxin-A (BoNT-A) is effective for the treatment of interstitial cystitis/painful bladder syndrome (IC/PBS). However, long-term follow-up does not show successful outcome after a single injection. To evaluate the efficacy and safety of repeated intravesical BoNT-A injections for treatment of IC/PBS and compare the success rates among patient groups receiving different injection numbers. Prospective interventional study. Tertiary medical center. Intravesical injection of 100 U of BoNT-A was performed in 81 patients every 6 months for up to 4 times or until patients' symptoms significantly improved. Patients who received a single injection served as active controls. Measured parameters included O'Leary-Sant symptom indexes (ICSI) and problem indexes (ICPI), visual analogue score (VAS) for pain, voiding diary variables, urodynamic parameters, maximal bladder capacity under anesthesia, glomerulation grade, and global response assessment. Multiple measurements and Kaplan-Meier analysis were used for comparison of consecutive data and success rates among groups. Among 81 patients, 20 received single injections, 19 received 2 injections, 12 received 3 injections, and 30 received 4 injections. The mean (± standard deviation) of ICSI, ICPI, total scores, VAS, functional bladder capacity, and daytime frequency all showed significant improvement after repeated BoNT-A treatment with different injections. Significantly better success rates were noted in patients who received 4 repeated injections (P = 0.0242) and 3 injections (P = 0.050), compared to those who received a single injection. However, there was no significant difference of long-term success rates among patients who received 2, 3, and 4 injections. Lack of placebo control group is the main limitation. Repeated intravesical BoNT-A injections were safe and effective for pain relief and they increased bladder capacity and provided a better long-term success rate than a single injection did for treatment of IC/PBS.
Evaluation of reliability and validity of three dental color-matching devices.
Tsiliagkou, Aikaterini; Diamantopoulou, Sofia; Papazoglou, Efstratios; Kakaboura, Afrodite
2016-01-01
To assess the repeatability and accuracy of three dental color-matching devices under standardized and freehand measurement conditions. Two shade guides (Vita Classical A1-D4, Vita; and Vita Toothguide 3D-Master, Vita), and three color-matching devices (Easyshade, Vita; SpectroShade, MHT Optic Research; and ShadeVision, X-Rite) were used. Five shade tabs were selected from the Vita Classical A1-D4 (A2, A3.5, B1, C4, D3), and five from the Vita Toothguide 3D-Master (1M1, 2R1.5, 3M2, 4L2.5, 5M3) shade guides. Each shade tab was recorded 15 continuous, repeated times with each device under two different measurement conditions (standardized, and freehand). Both qualitative (color shade) and quantitative (L, a, and b) color characteristics were recorded. The color difference (ΔE) of each recorded value with the known values of the shade tab was calculated. The repeatability of each device was evaluated by the coefficient of variance. The accuracy of each device was determined by comparing the recorded values with the known values of the reference shade tab (one sample t test; α = 0.05). The agreement between the recorded shade and the reference shade tab was calculated. The influence of the parameters (devices and conditions) on the parameter ΔE was investigated (two-way ANOVA). Comparison of the devices was performed with Bonferroni pairwise post-hoc analysis. Under standardized conditions, repeatability of all three devices was very good, except for ShadeVision with Vita Classical A1-D4. Accuracy ranged from good to fair, depending on the device and the shade guide. Under freehand conditions, repeatability and accuracy for Easyshade and ShadeVision were negatively influenced, but not for SpectroShade, regardless of the shade guide. Based on the total of the color parameters assessed per device, SpectroShade was the most reliable of the three color-matching devices studied.
Few millimeter precision for baselines in the California Permanent GPS Geodetic Array
NASA Technical Reports Server (NTRS)
Lindqwister, Ulf J.; Zumberge, James F.; Webb, Frank H.; Blewitt, Geoffrey
1991-01-01
Geodetic measurements with Rogue GPS receivers from sites in the California Permanent GPS geodetic Array (PGGA) have been analyzed using the GIPSY orbit-determination and baseline-estimation software. Based on an unbiased selection of 23 daily measurements spanning 8 months, the LF contributions to the long-term repeatabilities of baseline measurements are approximately 5, 3, and 8 mm for the east, north, and vertical components. Short-term contributions to the long-term repeatabilities were evaluated by examining data from the week of October 21, 1990, which showed the lowest short-term scatter. For this week, daily repeatabilities of 2-3 mm in the horizontal and 4 mm in the vertical have been achieved for the 172-km JPL-Pinyon baseline, consistent with carrier phase date noise of about 6 mm. High quality (less than about 5 mm) repeatabilities have been achieved for all components of the other baselines as well.
Cling film as a barrier against CJD in corneal contact A-scan ultrasonography.
Rani, Asha; Dunne, Mark C M; Barnes, Derek A
2003-01-01
To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another.
Cognitive outcome in adolescents and young adults after repeat courses of antenatal corticosteroids.
Stålnacke, Johanna; Diaz Heijtz, Rochellys; Norberg, Hanna; Norman, Mikael; Smedler, Ann-Charlotte; Forssberg, Hans
2013-08-01
To investigate whether repeat courses of antenatal corticosteroids have long-term effects on cognitive and psychological functioning. In a prospective cohort study, 58 adolescents and young adults (36 males) who had been exposed to 2-9 weekly courses of betamethasone in utero were assessed with neuropsychological tests and behavior self-reports. Unexposed subjects (n = 44, 25 males) matched for age, sex, and gestational age at birth served as a comparison group. In addition, individuals exposed in utero to a single course (n = 25, 14 males) were included for dose-response analysis. Group differences were investigated using multilevel linear modeling. Mean scores obtained in 2 measures of attention and speed were significantly lower in subjects exposed to 2 or more antenatal corticosteroids courses (Symbol Search, P = .009; Digit Span Forward, P = .02), but these were not dose-dependent. Exposure to repeat courses of antenatal corticosteroids was not associated with general deficits in higher cognitive functions, self-reported attention, adaptability, or overall psychological function. Although this study indicates that repeat exposure to antenatal corticosteroids may have an impact on aspects of executive functioning, it does not provide support for the prevailing concern that such fetal exposure will have a major adverse impact on cognitive functions and psychological health later in life. Copyright © 2013 Mosby, Inc. All rights reserved.
Automated Neuropsychological Assessment Metrics: Repeated Assessment with Two Military Samples
2011-01-01
to ra- diation, high altitude, undersea conditions, and toxins ( 10,14,20 ). The putative advantages of ANAM4 (com- pared to other...repeated measures ANOVA. Separate analyses were performed for each of the ANAM subtests. Session was treated as a repeated variable. Huynh-Feldt epsilon