ERIC Educational Resources Information Center
Putten, Jim Vander; Nolen, Amanda L.
2010-01-01
This study compared qualitative research results obtained by manual constant comparative analysis with results obtained by computer software analysis of the same data. An investigated about issues of trustworthiness and accuracy ensued. Results indicated that the inductive constant comparative data analysis generated 51 codes and two coding levels…
Comparability of river suspended-sediment sampling and laboratory analysis methods
Groten, Joel T.; Johnson, Gregory D.
2018-03-06
Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.
ERIC Educational Resources Information Center
Glover, Robert H.; Mills, Michael R.
A research design, decision support system, and results of a comparative analysis of enrollment and financial strength (of private institutions granting masters and doctoral degrees) are presented. Cluster analysis, discriminant analysis, multiple regression, and an interactive decision support system are used to compare the enrollment and…
COMPARE : a method for analyzing investment alternatives in industrial wood and bark energy systems
Peter J. Ince
1983-01-01
COMPARE is a FORTRAN computer program resulting from a study to develop methods for comparative economic analysis of alternatives in industrial wood and bark energy systems. COMPARE provides complete guidelines for economic analysis of wood and bark energy systems. As such, COMPARE can be useful to those who have only basic familiarity with investment analysis of wood...
Parametric and experimental analysis using a power flow approach
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1990-01-01
A structural power flow approach for the analysis of structure-borne transmission of vibrations is used to analyze the influence of structural parameters on transmitted power. The parametric analysis is also performed using the Statistical Energy Analysis approach and the results are compared with those obtained using the power flow approach. The advantages of structural power flow analysis are demonstrated by comparing the type of results that are obtained by the two analytical methods. Also, to demonstrate that the power flow results represent a direct physical parameter that can be measured on a typical structure, an experimental study of structural power flow is presented. This experimental study presents results for an L shaped beam for which an available solution was already obtained. Various methods to measure vibrational power flow are compared to study their advantages and disadvantages.
Schaefer, Alexander; Brach, Jennifer S.; Perera, Subashan; Sejdić, Ervin
2013-01-01
Background The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f) = 1/fβ. The scaling exponent β is thus often interpreted as a “biomarker” of relative health and decline. New Method This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. Results The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Comparison with Existing Methods: Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. Conclusions The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. PMID:24200509
NASA Astrophysics Data System (ADS)
Tátrai, Erika; Ranganathan, Sudarshan; Ferencz, Mária; Debuc, Delia Cabrera; Somfai, Gábor Márk
2011-05-01
Purpose: To compare thickness measurements between Fourier-domain optical coherence tomography (FD-OCT) and time-domain OCT images analyzed with a custom-built OCT retinal image analysis software (OCTRIMA). Methods: Macular mapping (MM) by StratusOCT and MM5 and MM6 scanning protocols by an RTVue-100 FD-OCT device are performed on 11 subjects with no retinal pathology. Retinal thickness (RT) and the thickness of the ganglion cell complex (GCC) obtained with the MM6 protocol are compared for each early treatment diabetic retinopathy study (ETDRS)-like region with corresponding results obtained with OCTRIMA. RT results are compared by analysis of variance with Dunnett post hoc test, while GCC results are compared by paired t-test. Results: A high correlation is obtained for the RT between OCTRIMA and MM5 and MM6 protocols. In all regions, the StratusOCT provide the lowest RT values (mean difference 43 +/- 8 μm compared to OCTRIMA, and 42 +/- 14 μm compared to RTVue MM6). All RTVue GCC measurements were significantly thicker (mean difference between 6 and 12 μm) than the GCC measurements of OCTRIMA. Conclusion: High correspondence of RT measurements is obtained not only for RT but also for the segmentation of intraretinal layers between FD-OCT and StratusOCT-derived OCTRIMA analysis. However, a correction factor is required to compensate for OCT-specific differences to make measurements more comparable to any available OCT device.
Comparison of iSTAT and EPOC Blood Analyzers
2017-10-25
requires accurate blood analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared... analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared gold standard laboratory...temperatures for either device can result in spurious results, particularly for blood gases. 2.0 BACKGROUND Blood analysis is a critical aspect of
Parametric and experimental analysis using a power flow approach
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1988-01-01
Having defined and developed a structural power flow approach for the analysis of structure-borne transmission of structural vibrations, the technique is used to perform an analysis of the influence of structural parameters on the transmitted energy. As a base for comparison, the parametric analysis is first performed using a Statistical Energy Analysis approach and the results compared with those obtained using the power flow approach. The advantages of using structural power flow are thus demonstrated by comparing the type of results obtained by the two methods. Additionally, to demonstrate the advantages of using the power flow method and to show that the power flow results represent a direct physical parameter that can be measured on a typical structure, an experimental investigation of structural power flow is also presented. Results are presented for an L-shaped beam for which an analytical solution has already been obtained. Furthermore, the various methods available to measure vibrational power flow are compared to investigate the advantages and disadvantages of each method.
Schaefer, Alexander; Brach, Jennifer S; Perera, Subashan; Sejdić, Ervin
2014-01-30
The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f)=1/f(β). The scaling exponent β is thus often interpreted as a "biomarker" of relative health and decline. This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. Copyright © 2013 Elsevier B.V. All rights reserved.
Investigation of Weibull statistics in fracture analysis of cast aluminum
NASA Technical Reports Server (NTRS)
Holland, Frederic A., Jr.; Zaretsky, Erwin V.
1989-01-01
The fracture strengths of two large batches of A357-T6 cast aluminum coupon specimens were compared by using two-parameter Weibull analysis. The minimum number of these specimens necessary to find the fracture strength of the material was determined. The applicability of three-parameter Weibull analysis was also investigated. A design methodology based on the combination of elementary stress analysis and Weibull statistical analysis is advanced and applied to the design of a spherical pressure vessel shell. The results from this design methodology are compared with results from the applicable ASME pressure vessel code.
NASA Technical Reports Server (NTRS)
Mei, Chuh; Pates, Carl S., III
1994-01-01
A coupled boundary element (BEM)-finite element (FEM) approach is presented to accurately model structure-acoustic interaction systems. The boundary element method is first applied to interior, two and three-dimensional acoustic domains with complex geometry configurations. Boundary element results are very accurate when compared with limited exact solutions. Structure-interaction problems are then analyzed with the coupled FEM-BEM method, where the finite element method models the structure and the boundary element method models the interior acoustic domain. The coupled analysis is compared with exact and experimental results for a simplistic model. Composite panels are analyzed and compared with isotropic results. The coupled method is then extended for random excitation. Random excitation results are compared with uncoupled results for isotropic and composite panels.
A global optimization approach to multi-polarity sentiment analysis.
Li, Xinmiao; Li, Jing; Wu, Yukeng
2015-01-01
Following the rapid development of social media, sentiment analysis has become an important social media mining technique. The performance of automatic sentiment analysis primarily depends on feature selection and sentiment classification. While information gain (IG) and support vector machines (SVM) are two important techniques, few studies have optimized both approaches in sentiment analysis. The effectiveness of applying a global optimization approach to sentiment analysis remains unclear. We propose a global optimization-based sentiment analysis (PSOGO-Senti) approach to improve sentiment analysis with IG for feature selection and SVM as the learning engine. The PSOGO-Senti approach utilizes a particle swarm optimization algorithm to obtain a global optimal combination of feature dimensions and parameters in the SVM. We evaluate the PSOGO-Senti model on two datasets from different fields. The experimental results showed that the PSOGO-Senti model can improve binary and multi-polarity Chinese sentiment analysis. We compared the optimal feature subset selected by PSOGO-Senti with the features in the sentiment dictionary. The results of this comparison indicated that PSOGO-Senti can effectively remove redundant and noisy features and can select a domain-specific feature subset with a higher-explanatory power for a particular sentiment analysis task. The experimental results showed that the PSOGO-Senti approach is effective and robust for sentiment analysis tasks in different domains. By comparing the improvements of two-polarity, three-polarity and five-polarity sentiment analysis results, we found that the five-polarity sentiment analysis delivered the largest improvement. The improvement of the two-polarity sentiment analysis was the smallest. We conclude that the PSOGO-Senti achieves higher improvement for a more complicated sentiment analysis task. We also compared the results of PSOGO-Senti with those of the genetic algorithm (GA) and grid search method. From the results of this comparison, we found that PSOGO-Senti is more suitable for improving a difficult multi-polarity sentiment analysis problem.
Urner, Martin; Twerenbold, Claudia; Kern, Sabine; Brügger, Urs; Spahn, Donat R.; Beck-Schimmer, Beatrice; Ganter, Michael T.
2017-01-01
BACKGROUND: Pharmacologic pre- and postconditioning with sevoflurane compared with total IV anesthesia in patients undergoing liver surgery reduced complication rates as shown in 2 recent randomized controlled trials. However, the potential health economic consequences of these different anesthesia regimens have not yet been assessed. METHODS: An expostcost analysis of these 2 trials in 129 patients treated between 2006 and 2010 was performed. We analyzed direct medical costs for in-hospital stay and compared pharmacologic pre- and postconditioning with sevoflurane (intervention) with total IV anesthesia (control) from the perspective of a Swiss university hospital. Year 2015 costs, converted to US dollars, were derived from hospital cost accounting data and compared with a multivariable regression analysis adjusting for relevant covariables. Costs with negative prefix indicate savings and costs with positive prefix represent higher spending in our analysis. RESULTS: Treatment-related costs per patient showed a nonsignificant change by −12,697 US dollars (95% confidence interval [CI], 10,956 to −36,352; P = .29) with preconditioning and by −6139 US dollars (95% CI, 6723 to −19,000; P = .35) with postconditioning compared with the control group. Results were robust in our sensitivity analysis. For both procedures (control and intervention) together, major complications led to a significant increase in costs by 86,018 US dollars (95% CI, 13,839-158,198; P = .02) per patient compared with patients with no major complications. CONCLUSIONS: In this cost analysis, reduced in-hospital costs by pharmacologic conditioning with sevoflurane in patients undergoing liver surgery are suggested. This possible difference in costs compared with total IV anesthesia is the result of reduced complication rates with pharmacologic conditioning, because major complications have significant cost implications. PMID:28067701
Evans, Alistair R.; McHenry, Colin R.
2015-01-01
The reliability of finite element analysis (FEA) in biomechanical investigations depends upon understanding the influence of model assumptions. In producing finite element models, surface mesh resolution is influenced by the resolution of input geometry, and influences the resolution of the ensuing solid mesh used for numerical analysis. Despite a large number of studies incorporating sensitivity studies of the effects of solid mesh resolution there has not yet been any investigation into the effect of surface mesh resolution upon results in a comparative context. Here we use a dataset of crocodile crania to examine the effects of surface resolution on FEA results in a comparative context. Seven high-resolution surface meshes were each down-sampled to varying degrees while keeping the resulting number of solid elements constant. These models were then subjected to bite and shake load cases using finite element analysis. The results show that incremental decreases in surface resolution can result in fluctuations in strain magnitudes, but that it is possible to obtain stable results using lower resolution surface in a comparative FEA study. As surface mesh resolution links input geometry with the resulting solid mesh, the implication of these results is that low resolution input geometry and solid meshes may provide valid results in a comparative context. PMID:26056620
Caballero, Julio; Fernández, Michael; Coll, Deysma
2010-12-01
Three-dimensional quantitative structure-activity relationship studies were carried out on a series of 28 organosulphur compounds as 15-lipoxygenase inhibitors using comparative molecular field analysis and comparative molecular similarity indices analysis. Quantitative information on structure-activity relationships is provided for further rational development and direction of selective synthesis. All models were carried out over a training set including 22 compounds. The best comparative molecular field analysis model only included steric field and had a good Q² = 0.789. Comparative molecular similarity indices analysis overcame the comparative molecular field analysis results: the best comparative molecular similarity indices analysis model also only included steric field and had a Q² = 0.894. In addition, this model predicted adequately the compounds contained in the test set. Furthermore, plots of steric comparative molecular similarity indices analysis field allowed conclusions to be drawn for the choice of suitable inhibitors. In this sense, our model should prove useful in future 15-lipoxygenase inhibitor design studies. © 2010 John Wiley & Sons A/S.
ERIC Educational Resources Information Center
Valentine, Jeffrey C.; McHugh, Cathleen M.
2007-01-01
Using meta-analysis, randomized experiments in education that either clearly did or clearly did not experience student attrition were examined for the baseline comparability of groups. Results from 35 studies suggested that after attrition, the observed measures of baseline comparability of groups did not differ more than would be expected given…
NASA Astrophysics Data System (ADS)
Salleh, S. A.; Rahman, A. S. A. Abd; Othman, A. N.; Mohd, W. M. N. Wan
2018-02-01
As different approach produces different results, it is crucial to determine the methods that are accurate in order to perform analysis towards the event. This research aim is to compare the Rank Reciprocal (MCDM) and Artificial Neural Network (ANN) analysis techniques in determining susceptible zones of landslide hazard. The study is based on data obtained from various sources such as local authority; Dewan Bandaraya Kuala Lumpur (DBKL), Jabatan Kerja Raya (JKR) and other agencies. The data were analysed and processed using Arc GIS. The results were compared by quantifying the risk ranking and area differential. It was also compared with the zonation map classified by DBKL. The results suggested that ANN method gives better accuracy compared to MCDM with 18.18% higher accuracy assessment of the MCDM approach. This indicated that ANN provides more reliable results and it is probably due to its ability to learn from the environment thus portraying realistic and accurate result.
NASA Technical Reports Server (NTRS)
Hodges, Robert V.; Nixon, Mark W.; Rehfield, Lawrence W.
1987-01-01
A methodology was developed for the structural analysis of composite rotor blades. This coupled-beam analysis is relatively simple to use compared with alternative analysis techniques. The beam analysis was developed for thin-wall single-cell rotor structures and includes the effects of elastic coupling. This paper demonstrates the effectiveness of the new composite-beam analysis method through comparison of its results with those of an established baseline analysis technique. The baseline analysis is an MSC/NASTRAN finite-element model built up from anisotropic shell elements. Deformations are compared for three linear static load cases of centrifugal force at design rotor speed, applied torque, and lift for an ideal rotor in hover. A D-spar designed to twist under axial loading is the subject of the analysis. Results indicate the coupled-beam analysis is well within engineering accuracy.
Independent Orbiter Assessment (IOA): Assessment of the backup flight system FMEA/CIL
NASA Technical Reports Server (NTRS)
Prust, E. E.; Ewell, J. J., Jr.; Hinsdale, L. W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Backup Flight System (BFS) hardware, generating draft failure modes and Potential Critical Items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed NASA Post 51-L FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter BFS hardware. The IOA product for the BFS analysis consisted of 29 failure mode worksheets that resulted in 21 Potential Critical Items (PCI) being identified. This product was originally compared with the proposed NASA BFS baseline and subsequently compared with the applicable Data Processing System (DPS), Electrical Power Distribution and Control (EPD and C), and Displays and Controls NASA CIL items. The comparisons determined if there were any results which had been found by the IOA but were not in the NASA baseline. The original assessment determined there were numerous failure modes and potential critical items in the IOA analysis that were not contained in the NASA BFS baseline. Conversely, the NASA baseline contained three FMEAs (IMU, ADTA, and Air Data Probe) for CIL items that were not identified in the IOA product.
NASA Technical Reports Server (NTRS)
Williams, Daniel M.; Consiglio, Maria C.; Murdoch, Jennifer L.; Adams, Catherine H.
2005-01-01
This paper provides an analysis of Flight Technical Error (FTE) from recent SATS experiments, called the Higher Volume Operations (HVO) Simulation and Flight experiments, which NASA conducted to determine pilot acceptability of the HVO concept for normal operating conditions. Reported are FTE results from simulation and flight experiment data indicating the SATS HVO concept is viable and acceptable to low-time instrument rated pilots when compared with today s system (baseline). Described is the comparative FTE analysis of lateral, vertical, and airspeed deviations from the baseline and SATS HVO experimental flight procedures. Based on FTE analysis, all evaluation subjects, low-time instrument-rated pilots, flew the HVO procedures safely and proficiently in comparison to today s system. In all cases, the results of the flight experiment validated the results of the simulation experiment and confirm the utility of the simulation platform for comparative Human in the Loop (HITL) studies of SATS HVO and Baseline operations.
Extension of vibrational power flow techniques to two-dimensional structures
NASA Technical Reports Server (NTRS)
Cuschieri, Joseph M.
1988-01-01
In the analysis of the vibration response and structure-borne vibration transmission between elements of a complex structure, statistical energy analysis (SEA) or finite element analysis (FEA) are generally used. However, an alternative method is using vibrational power flow techniques which can be especially useful in the mid frequencies between the optimum frequency regimes for SEA and FEA. Power flow analysis has in general been used on 1-D beam-like structures or between structures with point joints. In this paper, the power flow technique is extended to 2-D plate-like structures joined along a common edge without frequency or spatial averaging the results, such that the resonant response of the structure is determined. The power flow results are compared to results obtained using FEA results at low frequencies and SEA at high frequencies. The agreement with FEA results is good but the power flow technique has an improved computational efficiency. Compared to the SEA results the power flow results show a closer representation of the actual response of the structure.
NASA Technical Reports Server (NTRS)
Viezee, W.; Russell, P. B.; Hake, R. D., Jr.
1974-01-01
The matching method of lidar data analysis is explained, and the results from two flights studying the stratospheric aerosol using lidar techniques are summarized and interpreted. Support is lent to the matching method of lidar data analysis by the results, but it is not yet apparent that the analysis technique leads to acceptable results on all nights in all seasons.
Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol
2013-02-01
Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.
ERIC Educational Resources Information Center
Liu, Shujie; Xu, Xianxuan; Grant, Leslie; Strong, James; Fang, Zheng
2017-01-01
This article presents the results of an interpretive policy analysis of China's Ministry of Education Standards (2013) for the professional practice of principals. In addition to revealing the evolution of the evaluation of principals in China and the processes by which this policy is formulated, a comparative analysis was conducted to compare it…
Lee, O-Sung; Ahn, Soyeon; Lee, Yong Seuk
2017-07-01
The purpose of this systematic review and meta-analysis was to evaluate the effectiveness and safety of early weight-bearing by comparing clinical and radiological outcomes between early and traditional delayed weight-bearing after OWHTO. A rigorous and systematic approach was used. The methodological quality was also assessed. Results that are possible to be compared in two or more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random-effects model was used to calculate the effect size. Six articles were included in the final analysis. All case groups were composed of early full weight-bearing within 2 weeks. All control groups were composed of late full weight-bearing between 6 weeks and 2 months. Pooled analysis was possible for the improvement in Lysholm score, but there was no statistically significant difference shown between groups. Other clinical results were also similar between groups. Four studies reported mechanical femorotibial angle (mFTA) and this result showed no statistically significant difference between groups in the pooled analysis. Furthermore, early weight-bearing showed more favorable results in some radiologic results (osseointegration and patellar height) and complications (thrombophlebitis and recurrence). Our analysis supports that early full weight-bearing after OWHTO using a locking plate leads to improvement in outcomes and was comparable to the delayed weight-bearing in terms of clinical and radiological outcomes. On the contrary, early weight-bearing was more favorable with respect to some radiologic parameters and complications compared with delayed weight-bearing.
Desova, A A; Dorofeyuk, A A; Anokhin, A M
2017-01-01
We performed a comparative analysis of the types of spectral density typical of various parameters of pulse signal. The experimental material was obtained during the examination of school age children with various psychosomatic disorders. We also performed a typological analysis of the spectral density functions corresponding to the time series of different parameters of a single oscillation of pulse signals; the results of their comparative analysis are presented. We determined the most significant spectral components for two disordersin children: arterial hypertension and mitral valve prolapse.
Comparative study of Sperm Motility Analysis System and conventional microscopic semen analysis
KOMORI, KAZUHIKO; ISHIJIMA, SUMIO; TANJAPATKUL, PHANU; FUJITA, KAZUTOSHI; MATSUOKA, YASUHIRO; TAKAO, TETSUYA; MIYAGAWA, YASUSHI; TAKADA, SHINGO; OKUYAMA, AKIHIKO
2006-01-01
Background and Aim: Conventional manual sperm analysis still shows variations in structure, process and outcome although World Health Organization (WHO) guidelines present an appropriate method for sperm analysis. In the present study a new system for sperm analysis, Sperm Motility Analysis System (SMAS), was compared with manual semen analysis based on WHO guidelines. Materials and methods: Samples from 30 infertility patients and 21 healthy volunteers were subjected to manual microscopic analysis and SMAS analysis, simultaneously. We compared these two methods with respect to sperm concentration and percent motility. Results: Sperm concentrations obtained by SMAS (Csmas) and manual microscopic analyses on WHO guidelines (Cwho) were strongly correlated (Cwho = 1.325 × Csmas; r = 0.95, P < 0.001). If we excluded subjects with Csmas values >30 × 106 sperm/mL, the results were more similar (Cwho = 1.022 × Csmas; r = 0.81, P < 0.001). Percent motility obtained by SMAS (Msmas) and manual analysis on WHO guidelines (Mwho) were strongly correlated (Mwho = 1.214 × Msmas; r = 0.89, P < 0.001). Conclusions: The data indicate that the results of SMAS and those of manual microscopic sperm analyses based on WHO guidelines are strongly correlated. SMAS is therefore a promising system for sperm analysis. (Reprod Med Biol 2006; 5: 195–200) PMID:29662398
COMPARATIVE ANALYSIS OF HEALTH RISK ASSESSMENTS FOR MUNICIPAL WASTE COMBUSTORS
Quantitative health risk assessments have been performed for a number of proposed municipal waste combustor (MWC) facilities over the past several years. his article presents the results of a comparative analysis of a total of 21 risk assessments, focusing on seven of the most co...
Extension of vibrational power flow techniques to two-dimensional structures
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1987-01-01
In the analysis of the vibration response and structure-borne vibration transmission between elements of a complex structure, statistical energy analysis (SEA) or Finite Element Analysis (FEA) are generally used. However, an alternative method is using vibrational power flow techniques which can be especially useful in the mid- frequencies between the optimum frequency regimes for FEA and SEA. Power flow analysis has in general been used on one-dimensional beam-like structures or between structures with point joints. In this paper, the power flow technique is extended to two-dimensional plate like structures joined along a common edge without frequency or spatial averaging the results, such that the resonant response of the structure is determined. The power flow results are compared to results obtained using FEA at low frequencies and SEA at high frequencies. The agreement with FEA results is good but the power flow technique has an improved computational efficiency. Compared to the SEA results the power flow results show a closer representation of the actual response of the structure.
NASA Astrophysics Data System (ADS)
Surtikanti, Hertien Koosbandiah
2017-05-01
The Biotic Index was developed in Western Countries in response to the need in water quality evaluation. This method analysis is based on the classification of aquatic macrobenthos as a bioindicator for clean and polluted water. The aim of this study is to compare the analysis of Cikapundung river using 6 different Biotic Indexes. BI Shannon-Weiner, Belgian Biological Index (BBI), Family Biotic Index (FBI), Biological Monitoring Working Party (BMWP), Biological Monitoring Working Party-Average Score Per Taxon (BMWP-ASPT), and A Scoring System for Macroinvertebrate in Australian River (A SIGNAL). Those analysis are compared with Physical Water Index (CPI) which is developed in Indonesia. The result shows that a decreasing water quality is detected upstream to downstream of Cikapundung River. However, based on the CPI analysis result, the BMWP-ASPT biotic index analysis is more comprehensive than other BI in explaining Cikapundung water quality.
Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal
2017-11-24
Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.
Descalzo, Miguel Á; Garcia, Virginia Villaverde; González-Alvaro, Isidoro; Carbonell, Jordi; Balsa, Alejandro; Sanmartí, Raimon; Lisbona, Pilar; Hernandez-Barrera, Valentín; Jiménez-Garcia, Rodrigo; Carmona, Loreto
2013-02-01
To describe the results of different statistical ways of addressing radiographic outcome affected by missing data--multiple imputation technique, inverse probability weights and complete case analysis--using data from an observational study. A random sample of 96 RA patients was selected for a follow-up study in which radiographs of hands and feet were scored. Radiographic progression was tested by comparing the change in the total Sharp-van der Heijde radiographic score (TSS) and the joint erosion score (JES) from baseline to the end of the second year of follow-up. MI technique, inverse probability weights in weighted estimating equation (WEE) and CC analysis were used to fit a negative binomial regression. Major predictors of radiographic progression were JES and joint space narrowing (JSN) at baseline, together with baseline disease activity measured by DAS28 for TSS and MTX use for JES. Results from CC analysis show larger coefficients and s.e.s compared with MI and weighted techniques. The results from the WEE model were quite in line with those of MI. If it seems plausible that CC or MI analysis may be valid, then MI should be preferred because of its greater efficiency. CC analysis resulted in inefficient estimates or, translated into non-statistical terminology, could guide us into inaccurate results and unwise conclusions. The methods discussed here will contribute to the use of alternative approaches for tackling missing data in observational studies.
ERIC Educational Resources Information Center
Nugent, William R.
2017-01-01
Meta-analysis is a significant methodological advance that is increasingly important in research synthesis. Fundamental to meta-analysis is the presumption that effect sizes, such as the standardized mean difference (SMD), based on scores from different measures are comparable. It has been argued that population observed score SMDs based on scores…
Analysis of a Chevron Beam Thermal Actuator
NASA Astrophysics Data System (ADS)
Joshi, Amey Sanjay; Mohammed, Hussain; Kulkarni, S. M., Dr.
2018-02-01
Thermal MEMS (Micro-Electro-Mechanical Systems) actuators and sensors have a wide range of applications. The chevron type thermal actuators comparatively show superior performance over other existing electrostatic and thermal actuators. This paper describes the design and analysis of chevron type thermal actuator. Here standard design of Chevron type thermal actuator is considered which comprises of proof mass at center and array of six beams of a uniform cross section of 3 3 microns and an initial angle of 5°. The thermal actuator was designed and analyzed using analytical and finite element method and the results were compared. The model was also analyzed for initial angles of 2.5° and 7.5°, and the results were compared with FEA model. The cross section of the beam was varied and the finite element analysis of all three models was compared to suggest the best suitable thermal actuator structure.
NASA Technical Reports Server (NTRS)
1978-01-01
A three-dimensional finite elements analysis is reported of the nonlinear behavior of PCRV subjected to internal pressure by comparing calculated results with test results. As the first stage, an analysis considering the nonlinearity of cracking in concrete was attempted. As a result, it is found possible to make an analysis up to three times the design pressure (50 kg/sqcm), and calculated results agree well with test results.
Walmsley, Christopher W; McCurry, Matthew R; Clausen, Phillip D; McHenry, Colin R
2013-01-01
Finite element analysis (FEA) is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be 'reasonable' are often assumed to have little influence on the results and their interpretation. HERE WE REPORT AN EXTENSIVE SENSITIVITY ANALYSIS WHERE HIGH RESOLUTION FINITE ELEMENT (FE) MODELS OF MANDIBLES FROM SEVEN SPECIES OF CROCODILE WERE ANALYSED UNDER LOADS TYPICAL FOR COMPARATIVE ANALYSIS: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous), scaling (standardising volume, surface area, or length), tooth position (front, mid, or back tooth engagement), and linear load case (type of loading for each feeding type). Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different comparative datasets would also be sensitive to identical simulation assumptions; hence, modelling assumptions should undergo rigorous selection. The accuracy of input data is paramount, and simulations should focus on taking biological context into account. Ideally, validation of simulations should be addressed; however, where validation is impossible or unfeasible, sensitivity analyses should be performed to identify which assumptions have the greatest influence upon the results.
McCurry, Matthew R.; Clausen, Phillip D.; McHenry, Colin R.
2013-01-01
Finite element analysis (FEA) is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be ‘reasonable’ are often assumed to have little influence on the results and their interpretation. Here we report an extensive sensitivity analysis where high resolution finite element (FE) models of mandibles from seven species of crocodile were analysed under loads typical for comparative analysis: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous), scaling (standardising volume, surface area, or length), tooth position (front, mid, or back tooth engagement), and linear load case (type of loading for each feeding type). Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different comparative datasets would also be sensitive to identical simulation assumptions; hence, modelling assumptions should undergo rigorous selection. The accuracy of input data is paramount, and simulations should focus on taking biological context into account. Ideally, validation of simulations should be addressed; however, where validation is impossible or unfeasible, sensitivity analyses should be performed to identify which assumptions have the greatest influence upon the results. PMID:24255817
NASA Astrophysics Data System (ADS)
Randle, K.; Al-Jundi, J.; Mamas, C. J. V.; Sokhi, R. S.; Earwaker, L. G.
1993-06-01
Our work on heavy metals in the estuarine environment has involved the use of two multielement techniques: neutron activation analysis (NAA) and proton-induced X-ray emission (PIXE) analysis. As PIXE is essentially a surface analytical technique problems may arise due to sample inhomogeneity and surface roughness. In order to assess the contribution of these effects we have compared the results from PIXE analysis with those from a technique which analyzes a larger bulk sample rather than just the surface. An obvious method was NAA. A series of sediment samples containing particles of variable diameter were compared. Pellets containing a few mg of sediment were prepared from each sample and analyzed by the PIXE technique using both an absolute and a comparitive method. For INAA the rest of the sample was then irradiated with thermal neutrons and element concentrations determined from analyses of the subsequent gamma-ray spectrum. Results from the two methods are discussed.
Brooks, M.H.; Schroder, L.J.; Malo, B.A.
1985-01-01
Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)
Siegle, Cristhina Bonilha Huster; Dos Santos Cardoso de Sá, Cristina
2018-02-01
Exposure to HIV during pregnancy is a risks to development. Exposed child should have assessed its development since birth. Alberta Infant Motor Scale is a tool which assess gross motor skills, with easy application and low cost. Up to now, this scale had not proven its validity for the population exposed to HIV. It's necessary to compare its with a gold standard tool, Bayley scale, which assess gross and fine motor skills, has a high cost and longer application time required. Studies compare results of Alberta with Bayley's total motor score (gross + fine). However, it's also necessary to compare Alberta's result with only Bayley's gross motor result, because it's what both evaluate in common. to verify the concurrent validity of AIMS in infants exposed to HIV; to verify the correlation of AIMS and BSITD III for this population and to compare if these coefficients differ in the central age groups and extremities of the AIMS. 82 infants exposed to HIV evaluated in 1st, 2nd, 3rd, 4th, 8th, 12th, 15th, 16th, 17th and 18th months, with Alberta Infant Motor Scale and Bayley Scale (motor subscale). For analysis of concurrent validity, results of raw scores of the scales were compared with the correlation analysis. First analysis: Alberta's score with Bayley's total (gross + fine) motor score. Second analysis: Alberta's score with Bayley's gross motor score. In the first correlation analysis, results were: r = 0.62 in 1 st month, r = 0.64 in 2nd month, r = 0.08 in 3rd month, r = 0.45 in 4th month; r = 0.62 in 8th month, r = 0.60 in the 12th month. In the second correlation analysis, results were: r = 0.69 in 1 st month; r = 0.58 in 2nd month; r = 0.25 in 3rd month; r = 0.45 in the 4th month; r = 0.77 in 8th month; r = 0.73 in 12th month. Analyzes of the 15th, 16th, 17th and 18th months couldn't be performed because at these ages all the children had already reached the maximum score in the AIMS. Results were significant and indicate correlation between scales. Found results agree with other studies that found high correlations between the scales in premature and risk groups. However, these studies compare results of gross motor skills assessments with gross and fine motor skills assessments. Our results show that correlation only between the gross motor skills have higher coefficient values, and we believe this is the best way to compare the scales, with what both assessed in common. Alberta scale has correlation with Bayley scale in assessing of children exposed to HIV, and can be a substitute to Bayley in assessing of these children. Results are stronger when comparing only what both scales assess in common. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Black, Joshua A.; Knowles, Peter J.
2018-06-01
The performance of quasi-variational coupled-cluster (QV) theory applied to the calculation of activation and reaction energies has been investigated. A statistical analysis of results obtained for six different sets of reactions has been carried out, and the results have been compared to those from standard single-reference methods. In general, the QV methods lead to increased activation energies and larger absolute reaction energies compared to those obtained with traditional coupled-cluster theory.
Standardization of pitch-range settings in voice acoustic analysis.
Vogel, Adam P; Maruff, Paul; Snyder, Peter J; Mundt, James C
2009-05-01
Voice acoustic analysis is typically a labor-intensive, time-consuming process that requires the application of idiosyncratic parameters tailored to individual aspects of the speech signal. Such processes limit the efficiency and utility of voice analysis in clinical practice as well as in applied research and development. In the present study, we analyzed 1,120 voice files, using standard techniques (case-by-case hand analysis), taking roughly 10 work weeks of personnel time to complete. The results were compared with the analytic output of several automated analysis scripts that made use of preset pitch-range parameters. After pitch windows were selected to appropriately account for sex differences, the automated analysis scripts reduced processing time of the 1,120 speech samples to less than 2.5 h and produced results comparable to those obtained with hand analysis. However, caution should be exercised when applying the suggested preset values to pathological voice populations.
Binnicker, M. J.; Jespersen, D. J.; Harring, J. A.; Rollins, L. O.; Bryant, S. C.; Beito, E. M.
2008-01-01
The diagnosis of Lyme borreliosis (LB) is commonly made by serologic testing with Western blot (WB) analysis serving as an important supplemental assay. Although specific, the interpretation of WBs for diagnosis of LB (i.e., Lyme WBs) is subjective, with considerable variability in results. In addition, the processing, reading, and interpretation of Lyme WBs are laborious and time-consuming procedures. With the need for rapid processing and more objective interpretation of Lyme WBs, we evaluated the performances of two automated interpretive systems, TrinBlot/BLOTrix (Trinity Biotech, Carlsbad, CA) and BeeBlot/ViraScan (Viramed Biotech AG, Munich, Germany), using 518 serum specimens submitted to our laboratory for Lyme WB analysis. The results of routine testing with visual interpretation were compared to those obtained by BLOTrix analysis of MarBlot immunoglobulin M (IgM) and IgG and by ViraScan analysis of ViraBlot and ViraStripe IgM and IgG assays. BLOTrix analysis demonstrated an agreement of 84.7% for IgM and 87.3% for IgG compared to visual reading and interpretation. ViraScan analysis of the ViraBlot assays demonstrated agreements of 85.7% for IgM and 94.2% for IgG, while ViraScan analysis of the ViraStripe IgM and IgG assays showed agreements of 87.1 and 93.1%, respectively. Testing by the automated systems yielded an average time savings of 64 min/run compared to processing, reading, and interpretation by our current procedure. Our findings demonstrated that automated processing and interpretive systems yield results comparable to those of visual interpretation, while reducing the subjectivity and time required for Lyme WB analysis. PMID:18463211
Binnicker, M J; Jespersen, D J; Harring, J A; Rollins, L O; Bryant, S C; Beito, E M
2008-07-01
The diagnosis of Lyme borreliosis (LB) is commonly made by serologic testing with Western blot (WB) analysis serving as an important supplemental assay. Although specific, the interpretation of WBs for diagnosis of LB (i.e., Lyme WBs) is subjective, with considerable variability in results. In addition, the processing, reading, and interpretation of Lyme WBs are laborious and time-consuming procedures. With the need for rapid processing and more objective interpretation of Lyme WBs, we evaluated the performances of two automated interpretive systems, TrinBlot/BLOTrix (Trinity Biotech, Carlsbad, CA) and BeeBlot/ViraScan (Viramed Biotech AG, Munich, Germany), using 518 serum specimens submitted to our laboratory for Lyme WB analysis. The results of routine testing with visual interpretation were compared to those obtained by BLOTrix analysis of MarBlot immunoglobulin M (IgM) and IgG and by ViraScan analysis of ViraBlot and ViraStripe IgM and IgG assays. BLOTrix analysis demonstrated an agreement of 84.7% for IgM and 87.3% for IgG compared to visual reading and interpretation. ViraScan analysis of the ViraBlot assays demonstrated agreements of 85.7% for IgM and 94.2% for IgG, while ViraScan analysis of the ViraStripe IgM and IgG assays showed agreements of 87.1 and 93.1%, respectively. Testing by the automated systems yielded an average time savings of 64 min/run compared to processing, reading, and interpretation by our current procedure. Our findings demonstrated that automated processing and interpretive systems yield results comparable to those of visual interpretation, while reducing the subjectivity and time required for Lyme WB analysis.
Multi-Metric Sustainability Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cowlin, Shannon; Heimiller, Donna; Macknick, Jordan
2014-12-01
A readily accessible framework that allows for evaluating impacts and comparing tradeoffs among factors in energy policy, expansion planning, and investment decision making is lacking. Recognizing this, the Joint Institute for Strategic Energy Analysis (JISEA) funded an exploration of multi-metric sustainability analysis (MMSA) to provide energy decision makers with a means to make more comprehensive comparisons of energy technologies. The resulting MMSA tool lets decision makers simultaneously compare technologies and potential deployment locations.
Liu, Yuanyuan; Zhang, Yu; Feng, Gangling; Niu, Qiang; Xu, Shangzhi; Yan, Yizhong; Li, Shugang; Jing, Mingxia
2017-11-01
The present network meta-analysis aimed to compare the effectiveness and adverse effects of gefitinib, erlotinib and icotinib in the treatment of patients with non-small cell lung cancer (NSCLC). Two reviewers searched the Cochrane, PubMed, Embase, ScienceDirect, China National Knowledge Infrastructure, VIP Database for Chinese Technical Periodicals and Wanfang databases for relevant studies. Studies were then screened and evaluated, and data was extracted. End-points evaluated for NSCLC included complete response (CR), partial response (PR), stable disease (SD), progressive disease (PD), overall response rate (ORR), disease control rate (DCR), progression-free survival (PFS), median survival time (MST) and adverse effects, including rash, diarrhea, nausea and vomiting, fatigue and abnormal liver function. For the analysis of incorporated studies, RevMan, SPSS, R and Stata software were used. A total of 43 studies with 7,168 patients were included in the network meta-analysis. No significant differences were observed in CR, PR, SD, PD, ORR or DCR between gefitinib, erlotinib and icotinib by using network meta analysis. Compared with gefitinib, erlotinib resulted in a higher rate of nausea and vomiting [adjusted odds ratio (OR)=2.0; 95% credible interval, 1.1-3.7]. However, no significant differences were observed in the rates of rash, diarrhea, fatigue or abnormal liver function using network meta-analysis. Compared with erlotinib, gefitinib resulted in a lower SD rate [OR=0.86; 95% confidence interval (CI): 0.75-0.99; P=0.04], and lower rates of rash (OR=0.45; 95% CI, 0.36-0.55; P<0.00001), diarrhea (OR=0.75; 95% CI, 0.61-0.92; P=0.005), nausea and vomiting (OR=0.47; 95% CI, 0.27-0.84; P=0.01) and fatigue (OR=0.43; 95% CI, 0.24-0.76; P=0.004) through meta-analysis of two congruent drugs. However, gefitinib resulted in a higher rate of rash compared with icotinib (OR=1.57; 95% CI, 1.18-2.09; P=0.002). Otherwise, no significant differences were observed in CR, PR, PD, ORR, DCR and abnormal liver function between gefitinib, erlotinib and icotinib through meta-analysis of two congruent drugs. The PFS rate for gefitinib, erlotinib and icotinib was 5.48, 5.15 and 5.81 months, respectively. The MST was 13.26, 13.52, 12.58 months for gefitinib, erlotinib and icotinib, respectively. Gefitinib and icotinib resulted in significantly higher PFS rates compared with erlotinib (P<0.05). Erlotinib resulted in a significantly longer MST compared with gefitinib and icotinib (P<0.05). In conclusion, gefitinib, erlotinib and icotinib had similar effectiveness for the treatment of patients with advanced NSCLC. However, gefitinib resulted in a lower frequency of fatigue, and nausea and vomiting, compared with the other two drugs. Icotinib resulted in a lower frequency of rash. Erlotinib resulted in a longer MST, but was also associated with a higher frequency of rash, and nausea and vomiting.
Liu, Yuanyuan; Zhang, Yu; Feng, Gangling; Niu, Qiang; Xu, Shangzhi; Yan, Yizhong; Li, Shugang; Jing, Mingxia
2017-01-01
The present network meta-analysis aimed to compare the effectiveness and adverse effects of gefitinib, erlotinib and icotinib in the treatment of patients with non-small cell lung cancer (NSCLC). Two reviewers searched the Cochrane, PubMed, Embase, ScienceDirect, China National Knowledge Infrastructure, VIP Database for Chinese Technical Periodicals and Wanfang databases for relevant studies. Studies were then screened and evaluated, and data was extracted. End-points evaluated for NSCLC included complete response (CR), partial response (PR), stable disease (SD), progressive disease (PD), overall response rate (ORR), disease control rate (DCR), progression-free survival (PFS), median survival time (MST) and adverse effects, including rash, diarrhea, nausea and vomiting, fatigue and abnormal liver function. For the analysis of incorporated studies, RevMan, SPSS, R and Stata software were used. A total of 43 studies with 7,168 patients were included in the network meta-analysis. No significant differences were observed in CR, PR, SD, PD, ORR or DCR between gefitinib, erlotinib and icotinib by using network meta analysis. Compared with gefitinib, erlotinib resulted in a higher rate of nausea and vomiting [adjusted odds ratio (OR)=2.0; 95% credible interval, 1.1–3.7]. However, no significant differences were observed in the rates of rash, diarrhea, fatigue or abnormal liver function using network meta-analysis. Compared with erlotinib, gefitinib resulted in a lower SD rate [OR=0.86; 95% confidence interval (CI): 0.75–0.99; P=0.04], and lower rates of rash (OR=0.45; 95% CI, 0.36–0.55; P<0.00001), diarrhea (OR=0.75; 95% CI, 0.61–0.92; P=0.005), nausea and vomiting (OR=0.47; 95% CI, 0.27–0.84; P=0.01) and fatigue (OR=0.43; 95% CI, 0.24–0.76; P=0.004) through meta-analysis of two congruent drugs. However, gefitinib resulted in a higher rate of rash compared with icotinib (OR=1.57; 95% CI, 1.18–2.09; P=0.002). Otherwise, no significant differences were observed in CR, PR, PD, ORR, DCR and abnormal liver function between gefitinib, erlotinib and icotinib through meta-analysis of two congruent drugs. The PFS rate for gefitinib, erlotinib and icotinib was 5.48, 5.15 and 5.81 months, respectively. The MST was 13.26, 13.52, 12.58 months for gefitinib, erlotinib and icotinib, respectively. Gefitinib and icotinib resulted in significantly higher PFS rates compared with erlotinib (P<0.05). Erlotinib resulted in a significantly longer MST compared with gefitinib and icotinib (P<0.05). In conclusion, gefitinib, erlotinib and icotinib had similar effectiveness for the treatment of patients with advanced NSCLC. However, gefitinib resulted in a lower frequency of fatigue, and nausea and vomiting, compared with the other two drugs. Icotinib resulted in a lower frequency of rash. Erlotinib resulted in a longer MST, but was also associated with a higher frequency of rash, and nausea and vomiting. PMID:29104622
NASA Astrophysics Data System (ADS)
Paik, Daehwa; Miyahara, Masaya; Matsuzawa, Akira
This paper analyzes a pseudo-differential dynamic comparator with a dynamic pre-amplifier. The transient gain of a dynamic pre-amplifier is derived and applied to equations of the thermal noise and the regeneration time of a comparator. This analysis enhances understanding of the roles of transistor's parameters in pre-amplifier's gain. Based on the calculated gain, two calibration methods are also analyzed. One is calibration of a load capacitance and the other is calibration of a bypass current. The analysis helps designers' estimation for the accuracy of calibration, dead-zone of a comparator with a calibration circuit, and the influence of PVT variation. The analyzed comparator uses 90-nm CMOS technology as an example and each estimation is compared with simulation results.
Core Needle Lung Biopsy Specimens: Adequacy for EGFR and KRAS Mutational Analysis
Zakowski, Maureen F.; Pao, William; Thornton, Raymond H.; Ladanyi, Marc; Kris, Mark G.; Rusch, Valerie W.; Rizvi, Naiyer A.
2013-01-01
OBJECTIVE The purpose of this study was to prospectively compare the adequacy of core needle biopsy specimens with the adequacy of specimens from resected tissue, the histologic reference standard, for mutational analysis of malignant tumors of the lung. SUBJECTS AND METHODS The first 18 patients enrolled in a phase 2 study of gefitinib for lung cancer in July 2004 through August 2005 underwent CT- or fluoroscopy-guided lung biopsy before the start of gefitinib therapy. Three weeks after gefitinib therapy, the patients underwent lung tumor resection. The results of EGFR and KRAS mutational analysis of the core needle biopsy specimens were compared with those of EGFR and KRAS mutational analysis of the surgical specimens. RESULTS Two specimens were unsatisfactory for mutational analysis. The results of mutational assay results of the other 16 specimens were the same as those of analysis of the surgical specimens obtained an average of 31 days after biopsy. CONCLUSION Biopsy with small (18- to 20-gauge) core needles can yield sufficient and reliable samples for mutational analysis. This technique is likely to become an important tool with the increasing use of pharmacotherapy based on the genetics of specific tumors in individual patients. PMID:20028932
Tsaousi, Georgia; Apostolidou, Eirini; Karakoulas, Konstantinos; Kouvelas, Dimitrios; Amaniti, Ekaterini
2016-01-01
Aims The aim of this study was to perform an up‐to‐date systematic review and meta‐analysis on the efficacy and safety of prophylactic administration of levetiracetam in brain tumour patients. Method A systematic review of studies published until April 2015 was conducted using Scopus/Elsevier, EMBASE and MEDLINE. The search was limited to articles reporting results from adult patients, suffering from brain tumour, undergoing supratentorial craniotomy for tumour resection or biopsy and administered levetiracetam in the perioperative period for seizure prophylaxis. Outcomes included the efficacy and safety of levetiracetam, as well as the tolerability of the specific regimen, defined by the discontinuation of the treatment due to side effects. Results The systematic review included 1148 patients from 12 studies comparing levetiracetam with no treatment, phenytoin and valproate, while only 243 patients from three studies, comparing levetiracetam vs phenytoin efficacy and safety, were included in the meta‐analysis. The combined results from the meta‐analysis showed that levetiracetam administration was followed by significantly fewer seizures than treatment with phenytoin (OR = 0.12 [0.03–0.42]: χ2 = 1.76: I2 = 0%). Analysis also showed significantly fewer side effects in patients receiving levetiracetam, compared to other groups (P < 0.05). The combined results showed fewer side effects in the levetiracetam group compared to the phenytoin group (OR = 0.65 [0.14–2.99]: χ2 = 8.79: I2 = 77%). Conclusions The efficacy of prophylaxis with levetiracetam seems to be superior to that with phenytoin and valproate administration. Moreover, levetiracetam use demonstrates fewer side effects in brain tumour patients. Nevertheless, high risk of bias and moderate methodological quality must be taken into account when considering these results. PMID:26945547
Comparative Analysis of RF Emission Based Fingerprinting Techniques for ZigBee Device Classification
quantify the differences invarious RF fingerprinting techniques via comparative analysis of MDA/ML classification results. The findings herein demonstrate...correct classification rates followed by COR-DNA and then RF-DNA in most test cases and especially in low Eb/N0 ranges, where ZigBee is designed to operate.
Music Instruction and the Reading Achievement of Middle School Students
ERIC Educational Resources Information Center
Huber, Juanita J.
2010-01-01
Comparative analysis examined responses on a descriptive questionnaire from 267 students in grades 6, 7, and 8. The study compared duration of and participation in music instruction, types of musical instruments learned, and experience in musical ensembles to scores from the state English language arts assessment. Analysis of results included…
ERIC Educational Resources Information Center
Boden, Andrea; Archwamety, Teara; McFarland, Max
This review used meta-analytic techniques to integrate findings from 30 independent studies that compared programmed instruction to conventional methods of instruction at the secondary level. The meta-analysis demonstrated that programmed instruction resulted in higher achievement when compared to conventional methods of instruction (average…
ERIC Educational Resources Information Center
Agasisti, Tommaso; Perez-Esparrells, Carmen
2010-01-01
The growing internationalization of European Higher Education requires more emphasis on cross-country comparisons. In this paper, an efficiency analysis of Italian and Spanish universities is conducted; as well as from a comparative perspective. The efficiency scores are obtained using data envelopment analysis. The results demonstrate a good…
Eichler, Klaus; Urner, Martin; Twerenbold, Claudia; Kern, Sabine; Brügger, Urs; Spahn, Donat R; Beck-Schimmer, Beatrice; Ganter, Michael T
2017-03-01
Pharmacologic pre- and postconditioning with sevoflurane compared with total IV anesthesia in patients undergoing liver surgery reduced complication rates as shown in 2 recent randomized controlled trials. However, the potential health economic consequences of these different anesthesia regimens have not yet been assessed. An expostcost analysis of these 2 trials in 129 patients treated between 2006 and 2010 was performed. We analyzed direct medical costs for in-hospital stay and compared pharmacologic pre- and postconditioning with sevoflurane (intervention) with total IV anesthesia (control) from the perspective of a Swiss university hospital. Year 2015 costs, converted to US dollars, were derived from hospital cost accounting data and compared with a multivariable regression analysis adjusting for relevant covariables. Costs with negative prefix indicate savings and costs with positive prefix represent higher spending in our analysis. Treatment-related costs per patient showed a nonsignificant change by -12,697 US dollars (95% confidence interval [CI], 10,956 to -36,352; P = .29) with preconditioning and by -6139 US dollars (95% CI, 6723 to -19,000; P = .35) with postconditioning compared with the control group. Results were robust in our sensitivity analysis. For both procedures (control and intervention) together, major complications led to a significant increase in costs by 86,018 US dollars (95% CI, 13,839-158,198; P = .02) per patient compared with patients with no major complications. In this cost analysis, reduced in-hospital costs by pharmacologic conditioning with sevoflurane in patients undergoing liver surgery are suggested. This possible difference in costs compared with total IV anesthesia is the result of reduced complication rates with pharmacologic conditioning, because major complications have significant cost implications.
Combaret, Valérie; Iacono, Isabelle; Bréjon, Stéphanie; Schleiermacher, Gudrun; Pierron, Gäelle; Couturier, Jérôme; Bergeron, Christophe; Blay, Jean-Yves
2012-12-01
In cases of neuroblastoma, recurring genetic alterations--losses of the 1p, 3p, 4p, and 11q and/or gains of 1q, 2p, and 17q chromosome arms--are currently used to define the therapeutic strategy in therapeutic protocols for low- and intermediate-risk patients. Different genome-wide analysis techniques, such as array comparative genomic hybridization (aCGH) or multiplex ligation-dependent probe amplification (MLPA), have been suggested for detecting chromosome segmental abnormalities. In this study, we compared the results of the two technologies in the analyses of the DNA of tumor samples from 91 neuroblastoma patients. Similar results were obtained with the two techniques for 75 samples (82%). In five cases (5.5%), the MLPA results were not interpretable. Discrepancies between the aCGH and MLPA results were observed in 11 cases (12%). Among the discrepancies, a 18q21.2-qter gain and 16p11.2 and 11q14.1-q14.3 losses were detected only by aCGH. The MLPA results showed that the 7p, 7q, and 14q chromosome arms were affected in six cases, while in two cases, 2p and 17q gains were observed; these results were confirmed by neither aCGH nor fluorescence in situ hybridization (FISH) analysis. Because of the higher sensitivity and specificity of genome-wide information, reasonable cost, and shorter time of aCGH analysis, we recommend the aCGH procedure for the analysis of genomic alterations in neuroblastoma. Copyright © 2012 Elsevier Inc. All rights reserved.
Hydrocarbon group type determination in jet fuels by high performance liquid chromatography
NASA Technical Reports Server (NTRS)
Antoine, A. C.
1977-01-01
Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.
Iocca, Oreste; Farcomeni, Alessio; Pardiñas Lopez, Simon; Talib, Huzefa S
2017-01-01
To conduct a traditional meta-analysis and a Bayesian Network meta-analysis to synthesize the information coming from randomized controlled trials on different socket grafting materials and combine the resulting indirect evidence in order to make inferences on treatments that have not been compared directly. RCTs were identified for inclusion in the systematic review and subsequent statistical analysis. Bone height and width remodelling were selected as the chosen summary measures for comparison. First, a series of pairwise meta-analyses were performed and overall mean difference (MD) in mm with 95% CI was calculated between grafted versus non-grafted sockets. Then, a Bayesian Network meta-analysis was performed to draw indirect conclusions on which grafting materials can be considered most likely the best compared to the others. From the six included studies, seven comparisons were obtained. Traditional meta-analysis showed statistically significant results in favour of grafting the socket compared to no-graft both for height (MD 1.02, 95% CI 0.44-1.59, p value < 0.001) than for width (MD 1.52 95% CI 1.18-1.86, p value <0.000001) remodelling. Bayesian Network meta-analysis allowed to obtain a rank of intervention efficacy. On the basis of the results of the present analysis, socket grafting seems to be more favourable than unassisted socket healing. Moreover, Bayesian Network meta-analysis indicates that freeze-dried bone graft plus membrane is the most likely effective in the reduction of bone height remodelling. Autologous bone marrow resulted the most likely effective when width remodelling was considered. Studies with larger samples and less risk of bias should be conducted in the future in order to further strengthen the results of this analysis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ellart, J; François, C; Calibre, C; Guerreschi, P; Duquennoy-Martinot, V
2016-10-01
Breast asymmetry is defined by a difference in breast shape and/or volume. The goal of this study was to assess the stability of the surgical results and to highlight predictive factors for deterioration in results. This retrospective and monocentric study included all patients presenting constitutional isolated asymmetry, Poland's syndrome, asymmetric tuberous breast or pectus excavatum treated between 1980 and 2015. The statistical analysis included 144 patients and contained two parts. The first analysis compared patients with or without breast implant. Results were significant only for symmetry of shape, with better outcomes without breast implant (P=0.0170). The second analysis compared the subgroups of patients with breast asymmetry, according to the etiology. Patients with tuberous breasts and constitutional isolated asymmetry have been compared. We found a significant difference only regarding the long-term results (P=0.0091). Patients with tuberous breasts had deteriorating in results over time. Patients with Poland's syndrome, compared to patients with constitutional isolated asymmetry, had significantly less good results for symmetry of volume, of shape, of areola, and for early results (P<0.025). Concerning patients with pectus excavatum, the early and long-term results and the stability were good for most patients. Better results have been obtained with similar surgical procedures on both sides. Predictive factors for instability of results were the use of unilateral breast implant, weight variations, pregnancies and breast-feeding, the use of hormonal treatments, ageing and tuberous malformation. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
TRAC-PD2 posttest analysis of the CCTF Evaluation-Model Test C1-19 (Run 38). [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Motley, F.
The results of a Transient Reactor Analysis Code posttest analysis of the Cylindral Core Test Facility Evaluation-Model Test agree very well with the results of the experiment. The good agreement obtained verifies the multidimensional analysis capability of the TRAC code. Because of the steep radial power profile, the importance of using fine noding in the core region was demonstrated (as compared with poorer results obtained from an earlier pretest prediction that used a coarsely noded model).
Analysis of Wood Structure Connections Using Cylindrical Steel and Carbon Fiber Dowel Pins
NASA Astrophysics Data System (ADS)
Vodiannikov, Mikhail A.; Kashevarova, Galina G., Dr.
2017-06-01
In this paper, the results of the statistical analysis of corrosion processes and moisture saturation of glued laminated timber structures and their joints in corrosive environment are shown. This paper includes calculation results for dowel connections of wood structures using steel and carbon fiber reinforced plastic cylindrical dowel pins in accordance with applicable regulatory documents by means of finite element analysis in ANSYS software, as well as experimental findings. Dependence diagrams are shown; comparative analysis of the results obtained is conducted.
Jakusz, J.W.; Dieck, J.J.; Langrehr, H.A.; Ruhser, J.J.; Lubinski, S.J.
2016-01-11
Similar to an AA, validation involves generating random points based on the total area for each map class. However, instead of collecting field data, two or three individuals not involved with the photo-interpretative mapping separately review each of the points onscreen and record a best-fit vegetation type(s) for each site. Once the individual analyses are complete, results are joined together and a comparative analysis is performed. The objective of this initial analysis is to identify areas where the validation results were in agreement (matches) and areas where validation results were in disagreement (mismatches). The two or three individuals then perform an analysis, looking at each mismatched site, and agree upon a final validation class. (If two vegetation types at a specific site appear to be equally prevalent, the validation team is permitted to assign the site two best-fit vegetation types.) Following the validation team’s comparative analysis of vegetation assignments, the data are entered into a database and compared to the mappers’ vegetation assignments. Agreements and disagreements between the map and validation classes are identified, and a contingency table is produced. This document presents the AA processes/results for Pools 13 and La Grange, as well as the validation process/results for Pools 13 and 26 and Open River South.
Comparative Modelling of the Spectra of Cool Giants
NASA Technical Reports Server (NTRS)
Lebzelter, T.; Heiter, U.; Abia, C.; Eriksson, K.; Ireland, M.; Neilson, H.; Nowotny, W; Maldonado, J; Merle, T.; Peterson, R.;
2012-01-01
Our ability to extract information from the spectra of stars depends on reliable models of stellar atmospheres and appropriate techniques for spectral synthesis. Various model codes and strategies for the analysis of stellar spectra are available today. Aims. We aim to compare the results of deriving stellar parameters using different atmosphere models and different analysis strategies. The focus is set on high-resolution spectroscopy of cool giant stars. Methods. Spectra representing four cool giant stars were made available to various groups and individuals working in the area of spectral synthesis, asking them to derive stellar parameters from the data provided. The results were discussed at a workshop in Vienna in 2010. Most of the major codes currently used in the astronomical community for analyses of stellar spectra were included in this experiment. Results. We present the results from the different groups, as well as an additional experiment comparing the synthetic spectra produced by various codes for a given set of stellar parameters. Similarities and differences of the results are discussed. Conclusions. Several valid approaches to analyze a given spectrum of a star result in quite a wide range of solutions. The main causes for the differences in parameters derived by different groups seem to lie in the physical input data and in the details of the analysis method. This clearly shows how far from a definitive abundance analysis we still are.
NASA Technical Reports Server (NTRS)
1975-01-01
Gas turbine engines were assessed for application to hear duty transportation. A summary of the assumptions, applications, and methods of analysis is included along with a discussion of the approach taken, the technical program flow chart, and weighting criteria used for performance evaluation. The various engines are compared on the bases of weight, performance, emissions and noise, technology status, and growth potential. The results of the engine screening phase and the conceptual design phase are presented.
NASA Astrophysics Data System (ADS)
Ceran, Bartosz
2017-11-01
The paper presents the results of the use of multi-criteria analysis to compare hybrid power generation system collaboration scenarios (HSW) consisting of wind turbines, solar panels and energy storage electrolyzer - PEM type fuel cell with electricity system. The following scenarios were examined: the base S-I-hybrid system powers the off-grid mode receiver, S-II, S-III, S-IV scenarios-electricity system covers 25%, 50%, 75% of energy demand by the recipient. The effect of weights of the above-mentioned criteria on the final result of the multi-criteria analysis was examined.
NASA Astrophysics Data System (ADS)
Crawford, I.; Ruske, S.; Topping, D. O.; Gallagher, M. W.
2015-07-01
In this paper we present improved methods for discriminating and quantifying Primary Biological Aerosol Particles (PBAP) by applying hierarchical agglomerative cluster analysis to multi-parameter ultra violet-light induced fluorescence (UV-LIF) spectrometer data. The methods employed in this study can be applied to data sets in excess of 1×106 points on a desktop computer, allowing for each fluorescent particle in a dataset to be explicitly clustered. This reduces the potential for misattribution found in subsampling and comparative attribution methods used in previous approaches, improving our capacity to discriminate and quantify PBAP meta-classes. We evaluate the performance of several hierarchical agglomerative cluster analysis linkages and data normalisation methods using laboratory samples of known particle types and an ambient dataset. Fluorescent and non-fluorescent polystyrene latex spheres were sampled with a Wideband Integrated Bioaerosol Spectrometer (WIBS-4) where the optical size, asymmetry factor and fluorescent measurements were used as inputs to the analysis package. It was found that the Ward linkage with z-score or range normalisation performed best, correctly attributing 98 and 98.1 % of the data points respectively. The best performing methods were applied to the BEACHON-RoMBAS ambient dataset where it was found that the z-score and range normalisation methods yield similar results with each method producing clusters representative of fungal spores and bacterial aerosol, consistent with previous results. The z-score result was compared to clusters generated with previous approaches (WIBS AnalysiS Program, WASP) where we observe that the subsampling and comparative attribution method employed by WASP results in the overestimation of the fungal spore concentration by a factor of 1.5 and the underestimation of bacterial aerosol concentration by a factor of 5. We suggest that this likely due to errors arising from misatrribution due to poor centroid definition and failure to assign particles to a cluster as a result of the subsampling and comparative attribution method employed by WASP. The methods used here allow for the entire fluorescent population of particles to be analysed yielding an explict cluster attribution for each particle, improving cluster centroid definition and our capacity to discriminate and quantify PBAP meta-classes compared to previous approaches.
NASA Astrophysics Data System (ADS)
Sulik-Górecka, Aleksandra
2018-06-01
Modern manufacturing entities often operate in capital groups, and their role is sometimes limited to the function of cost centers. From the legal point of view, however, they are separate entities obliged to apply transfer pricing regulations. Meeting the requirements of the arm's length principle can be very difficult at this time, given the relationships and conflicts of interest in the capital group. Complexity increases in capital groups operating in different countries, due to differences in tax regulations. The main purpose of the paper is to demonstrate that the need to valuate the sale of finished goods to a manufacturing entity, which is a subject to a different tax jurisdiction, may lead to a problem of compliance with the arm's length principle. In addition, the paper proposes a methodology for comparability analysis that may be used by manufacturing entities to defend conditions of setting transfer pricing. The paper presents the different functional profiles of manufacturing entities and points out the difficulties that they may encounter when preparing the comparability analysis. It has also been noted that there are differences in transfer pricing regulations in different countries, for example by analyzing Polish and Czech regulations. The lack of uniform benchmarking legislation can cause inconsistencies in the selection of comparable data, resulting in differences in transfer pricing. The paper uses the method of legal regulation review and analysis of results of published studies concerning the scope of transfer pricing and comparability analysis. The paper also adopts a case study analysis.
SU-F-T-295: MLCs Performance and Patient-Specific IMRT QA Using Log File Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osman, A; American University of Biuret Medical Center, Biuret; Maalej, N
2016-06-15
Purpose: To analyze the performance of the multi-leaf collimators (MLCs) from the log files recorded during the intensity modulated radiotherapy (IMRT) treatment and to construct the relative fluence maps and do the gamma analysis to compare the planned and executed MLCs movement. Methods: We developed a program to extract and analyze the data from dynamic log files (dynalog files) generated from sliding window IMRT delivery treatments. The program extracts the planned and executed (actual or delivered) MLCs movement, calculates and compares the relative planned and executed fluences. The fluence maps were used to perform the gamma analysis (with 3% dosemore » difference and 3 mm distance to agreement) for 3 IMR patients. We compared our gamma analysis results with those obtained from portal dose image prediction (PDIP) algorithm performed using the EPID. Results: For 3 different IMRT patient treatments, the maximum difference between the planned and the executed MCLs positions was 1.2 mm. The gamma analysis results of the planned and delivered fluences were in good agreement with the gamma analysis from portal dosimetry. The maximum difference for number of pixels passing the gamma criteria (3%/3mm) was 0.19% with respect to portal dosimetry results. Conclusion: MLC log files can be used to verify the performance of the MLCs. Patientspecific IMRT QA based on MLC movement log files gives similar results to EPID dosimetry results. This promising method for patient-specific IMRT QA is fast, does not require dose measurements in a phantom, can be done before the treatment and for every fraction, and significantly reduces the IMRT workload. The author would like to thank King Fahd University of petroleum and Minerals for the support.« less
Pre/Post Data Analysis - Simple or Is It?
NASA Technical Reports Server (NTRS)
Feiveson, Al; Fiedler, James; Ploutz-Snyder, Robert
2011-01-01
This slide presentation reviews some of the problems of data analysis in analyzing pre and post data. Using as an example, ankle extensor strength (AES) experiments, to measure bone density loss during bed rest, the presentation discusses several questions: (1) How should we describe change? (2) Common analysis methods for comparing post to pre results. (3) What do we mean by "% change"? and (4) What are we testing when we compare % changes?
Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith GM; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-01-01
Background Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. Objective This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. Methods We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher’s tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). Results An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Conclusions Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use. PMID:26254160
NASA Astrophysics Data System (ADS)
Dalipi, Rogerta; Marguí, Eva; Borgese, Laura; Bilo, Fabjola; Depero, Laura E.
2016-06-01
Recent technological improvements have led to a widespread adoption of benchtop total reflection X-ray fluorescence systems (TXRF) for analysis of liquid samples. However, benchtop TXRF systems usually present limited sensitivity compared with high-scale instrumentation which can restrict its application in some fields. The aim of the present work was to evaluate and compare the analytical capabilities of two TXRF systems, equipped with low power Mo and W target X-ray tubes, for multielemental analysis of wine samples. Using the Mo-TXRF system, the detection limits for most elements were one order of magnitude lower than those attained using the W-TXRF system. For the detection of high Z elements like Cd and Ag, however, W-TXRF remains a very good option due to the possibility of K-Lines detection. Accuracy and precision of the obtained results have been evaluated analyzing spiked real wine samples and comparing the TXRF results with those obtained by inductively coupled plasma emission spectroscopy (ICP-OES). In general, good agreement was obtained between ICP-OES and TXRF results for the analysis of both red and white wine samples except for light elements (i.e., K) which TXRF concentrations were underestimated. However, a further achievement of analytical quality of TXRF results can be achieved if wine analysis is performed after dilution of the sample with de-ionized water.
Faucher, Mary Ann; Garner, Shelby L
2015-11-01
The purpose of this manuscript is to compare methods and thematic representations of the challenges and supports of family caregivers identified with photovoice methodology contrasted with content analysis, a more traditional qualitative approach. Results from a photovoice study utilizing a participatory action research framework was compared to an analysis of the audio-transcripts from that study utilizing content analysis methodology. Major similarities between the results are identified with some notable differences. Content analysis provides a more in-depth and abstract elucidation of the nature of the challenges and supports of the family caregiver. The comparison provides evidence to support the trustworthiness of photovoice methodology with limitations identified. The enhanced elaboration of theme and categories with content analysis may have some advantages relevant to the utilization of this knowledge by health care professionals. Copyright © 2015 Elsevier Inc. All rights reserved.
Stucki, Sheldon Lee; Biss, David J.
2000-01-01
An analysis was performed using the National Automotive Sampling System Crashworthiness Data System (NASS-CDS) database to compare the injury/fatality rates of variously restrained driver occupants as compared to unrestrained driver occupants in the total database of drivers/frontals, and also by Delta-V. A structured search of the NASS-CDS was done using the SAS® statistical analysis software to extract the data for this analysis and the SUDAAN software package was used to arrive at statistical significance indicators. In addition, this paper goes on to investigate different methods for presenting results of accident database searches including significance results; a risk versus Delta-V format for specific exposures; and, a percent cumulative injury versus Delta-V format to characterize injury trends. These alternative analysis presentation methods are then discussed by example using the present study results. PMID:11558105
Toh, Sengwee; Reichman, Marsha E; Houstoun, Monika; Ding, Xiao; Fireman, Bruce H; Gravel, Eric; Levenson, Mark; Li, Lingling; Moyneur, Erick; Shoaibi, Azadeh; Zornberg, Gwen; Hennessy, Sean
2013-11-01
It is increasingly necessary to analyze data from multiple sources when conducting public health safety surveillance or comparative effectiveness research. However, security, privacy, proprietary, and legal concerns often reduce data holders' willingness to share highly granular information. We describe and compare two approaches that do not require sharing of patient-level information to adjust for confounding in multi-site studies. We estimated the risks of angioedema associated with angiotensin-converting enzyme inhibitors (ACEIs), angiotensin receptor blockers (ARBs), and aliskiren in comparison with beta-blockers within Mini-Sentinel, which has created a distributed data system of 18 health plans. To obtain the adjusted hazard ratios (HRs) and 95% confidence intervals (CIs), we performed (i) a propensity score-stratified case-centered logistic regression analysis, a method identical to a stratified Cox regression analysis but needing only aggregated risk set data, and (ii) an inverse variance-weighted meta-analysis, which requires only the site-specific HR and variance. We also performed simulations to further compare the two methods. Compared with beta-blockers, the adjusted HR was 3.04 (95% CI: 2.81, 3.27) for ACEIs, 1.16 (1.00, 1.34) for ARBs, and 2.85 (1.34, 6.04) for aliskiren in the case-centered analysis. The corresponding HRs were 2.98 (2.76, 3.21), 1.15 (1.00, 1.33), and 2.86 (1.35, 6.04) in the meta-analysis. Simulations suggested that the two methods may produce different results under certain analytic scenarios. The case-centered analysis and the meta-analysis produced similar results without the need to share patient-level data across sites in our empirical study, but may provide different results in other study settings. Copyright © 2013 John Wiley & Sons, Ltd.
Chen, Qianqian; Xie, Qian; Zhao, Min; Chen, Bin; Gao, Shi; Zhang, Haishan; Xing, Hua; Ma, Qingjie
2015-01-01
To compare the diagnostic value of visual and semi-quantitative analysis of technetium-99m-poly-ethylene glycol, 4-arginine-glycine-aspartic acid ((99m)Tc-3PRGD2) scintimammography (SMG) for better differentiation of benign from malignant breast masses, and also investigate the incremental role of semi-quantitative index of SMG. A total of 72 patients with breast lesions were included in the study. Technetium-99m-3PRGD2 SMG was performed with single photon emission computed tomography (SPET) at 60 min after intravenous injection of 749 ± 86MBq of the radiotracer. Images were evaluated by visual interpretation and semi-quantitative indices of tumor to non-tumor (T/N) ratios, which were compared with pathology results. Receiver operating characteristics (ROC) curve analyses were performed to determine the optimal visual grade, to calculate cut-off values of semi-quantitative indices, and to compare visual and semi-quantitative diagnostic values. Among the 72 patients, 89 lesions were confirmed by histopathology after fine needle aspiration biopsy or surgery, 48 malignant and 41 benign lesions. The mean T/N ratio of (99m)Tc-3PRGD2 SMG in malignant lesions was significantly higher than that in benign lesions (P<0.05). When grade 2 of the disease was used as cut-off value for the detection of primary breast cancer, the sensitivity, specificity and accuracy were 81.3%, 70.7%, and 76.4%, respectively. When a T/N ratio of 2.01 was used as cut-off value, the sensitivity, specificity and accuracy were 79.2%, 75.6%, and 77.5%, respectively. According to ROC analysis, the area under the curve for semi-quantitative analysis was higher than that for visual analysis, but the statistical difference was not significant (P=0.372). Compared with visual analysis or semi-quantitative analysis alone, the sensitivity, specificity and accuracy of visual analysis combined with semi-quantitative analysis in diagnosing primary breast cancer were higher, being: 87.5%, 82.9%, and 85.4%, respectively. The area under the curve was 0.891. Results of the present study suggest that the semi-quantitative and visual analysis statistically showed similar results. The semi-quantitative analysis provided incremental value additive to visual analysis of (99m)Tc-3PRGD2 SMG for the detection of breast cancer. It seems from our results that, when the tumor was located in the medial part of the breast, the semi-quantitative analysis gave better diagnostic results.
A density difference based analysis of orbital-dependent exchange-correlation functionals
NASA Astrophysics Data System (ADS)
Grabowski, Ireneusz; Teale, Andrew M.; Fabiano, Eduardo; Śmiga, Szymon; Buksztel, Adam; Della Sala, Fabio
2014-03-01
We present a density difference based analysis for a range of orbital-dependent Kohn-Sham functionals. Results for atoms, some members of the neon isoelectronic series and small molecules are reported and compared with ab initio wave function calculations. Particular attention is paid to the quality of approximations to the exchange-only optimised effective potential (OEP) approach: we consider both the localised Hartree-Fock as well as the Krieger-Li-Iafrate methods. Analysis of density differences at the exchange-only level reveals the impact of the approximations on the resulting electronic densities. These differences are further quantified in terms of the ground state energies, frontier orbital energy differences and highest occupied orbital energies obtained. At the correlated level, an OEP approach based on a perturbative second-order correlation energy expression is shown to deliver results comparable with those from traditional wave function approaches, making it suitable for use as a benchmark against which to compare standard density functional approximations.
Roque, Matheus; Lattes, Karinna; Serra, Sandra; Solà, Ivan; Geber, Selmo; Carreras, Ramón; Checa, Miguel Angel
2013-01-01
To examine the available evidence to assess if cryopreservation of all embryos and subsequent frozen embryo transfer (FET) results in better outcomes compared with fresh transfer. Systematic review and meta-analysis. Centers for reproductive care. Infertility patient(s). An exhaustive electronic literature search in MEDLINE, EMBASE, and the Cochrane Library was performed through December 2011. We included randomized clinical trials comparing outcomes of IVF cycles between fresh and frozen embryo transfers. The outcomes of interest were ongoing pregnancy rate, clinical pregnancy rate, and miscarriage. We included three trials accounting for 633 cycles in women aged 27-33 years. Data analysis showed that FET resulted in significantly higher ongoing pregnancy rates and clinical pregnancy rates. Our results suggest that there is evidence that IVF outcomes may be improved by performing FET compared with fresh embryo transfer. This could be explained by a better embryo-endometrium synchrony achieved with endometrium preparation cycles. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Pesticides are commonly used for management of codling moth and diseases in apple, pear and walnut orchards in the western U.S. and these pesticides may disrupt the biological control of secondary pests in these crops. A comparative analysis was made of results obtained from a series of studies of ...
Comparing Response Rates in E-Mail and Paper Surveys: A Meta-Analysis
ERIC Educational Resources Information Center
Shih, Tse-Hua; Fan, Xitao
2009-01-01
This meta-analysis examined 35 study results within last 10 years that directly compared the response rates of e-mail versus mail surveys. Individual studies reported inconsistent findings concerning the response rate difference between e-mail and mail surveys, but e-mail surveys generally have lower response rate (about 20% lower on the average)…
Comparing Brief Experimental Analysis and Teacher Judgment for Selecting Early Reading Interventions
ERIC Educational Resources Information Center
Wagner, Dana L.; Coolong-Chaffin, Melissa; Deris, Aaron R.
2017-01-01
The purpose of this study was to examine the use of brief experimental analysis (BEA) to identify early reading interventions for students in the primary grades and to compare teachers' judgments about their students' early reading intervention needs to BEA results. In addition, the research was conducted to explore how teachers make decisions…
National Launch System comparative economic analysis
NASA Technical Reports Server (NTRS)
Prince, A.
1992-01-01
Results are presented from an analysis of economic benefits (or losses), in the form of the life cycle cost savings, resulting from the development of the National Launch System (NLS) family of launch vehicles. The analysis was carried out by comparing various NLS-based architectures with the current Shuttle/Titan IV fleet. The basic methodology behind this NLS analysis was to develop a set of annual payload requirements for the Space Station Freedom and LEO, to design launch vehicle architectures around these requirements, and to perform life-cycle cost analyses on all of the architectures. A SEI requirement was included. Launch failure costs were estimated and combined with the relative reliability assumptions to measure the effects of losses. Based on the analysis, a Shuttle/NLS architecture evolving into a pressurized-logistics-carrier/NLS architecture appears to offer the best long-term cost benefit.
Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam
2017-01-01
Aims and Objective: The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Materials and Methods: Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t-test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Results: Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. Conclusion: CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis. PMID:28852639
Marinov, V; Draganov, K; Gaydarski, R; Katev, N N
2013-01-01
There is a large variety of proposed conservative, invasive, endoscopic and surgical methods for treatment of chronic pancreatitis and its complications. This study presents a comparative analysis of the results from each group of patients subjected to drainage, resection, denervation and other operative techniques for a total of 91 patients with chronic pancreatitis and its complications. Drainage and resection operative techniques yield comparable results in terms of postoperative pain control 93.1% and 100%, perioperative mortality--3.17% and 5.8%, perioperative morbidity--7.9% and 11.7%, respectively. There is a significant increase in the instances of diabetes in the resection group. Right-side semilunar ganglionectomy is a good method for pain control as an accompanying procedure in the course of another main operative technique.
Naguib, Ibrahim A; Abdelrahman, Maha M; El Ghobashy, Mohamed R; Ali, Nesma A
2016-01-01
Two accurate, sensitive, and selective stability-indicating methods are developed and validated for simultaneous quantitative determination of agomelatine (AGM) and its forced degradation products (Deg I and Deg II), whether in pure forms or in pharmaceutical formulations. Partial least-squares regression (PLSR) and spectral residual augmented classical least-squares (SRACLS) are two chemometric models that are being subjected to a comparative study through handling UV spectral data in range (215-350 nm). For proper analysis, a three-factor, four-level experimental design was established, resulting in a training set consisting of 16 mixtures containing different ratios of interfering species. An independent test set consisting of eight mixtures was used to validate the prediction ability of the suggested models. The results presented indicate the ability of mentioned multivariate calibration models to analyze AGM, Deg I, and Deg II with high selectivity and accuracy. The analysis results of the pharmaceutical formulations were statistically compared to the reference HPLC method, with no significant differences observed regarding accuracy and precision. The SRACLS model gives comparable results to the PLSR model; however, it keeps the qualitative spectral information of the classical least-squares algorithm for analyzed components.
ERIC Educational Resources Information Center
Ward, Jacqueline M.
2011-01-01
Traditional education (TE) largely uses a standardized (SbE) approach while alternatives (nTE) tend to more of a competency (CbE), or student-centered approach. This comparative analysis examines essential aspects of such pedagogies in determining the effectiveness of schooling systems in meeting the Whole Child Initiative (Souza, 1999; Carter et…
Multivariate analysis of meat production traits in Murciano-Granadina goat kids.
Zurita-Herrera, P; Delgado, J V; Argüello, A; Camacho, M E
2011-07-01
Growth, carcass quality, and meat quality data from Murciano-Granadina kids (n=61) raised under three different systems were collected. Canonical discriminatory analysis and cluster analysis of the entire meat production process and its stages were performed using the rearing systems as grouping criteria. All comparisons resulted in significant differences and indicated the existence of three products with different quality characteristics as a result of the three rearing systems. Differences among groups were greater when comparing carcass and meat qualities as compared with growth differences. The paired analyses of canonical correlations among groups of variables integrated in growth, carcass and meat quality, resulted in all being statistically significant, pointing out the canonical correlation coefficient between carcass quality and meat quality. Copyright © 2011 Elsevier Ltd. All rights reserved.
1985-02-21
Approvoid foT public 90Ieleol, 2* . tJni7nited " - . - o . - ’--. * . -... . 1 UNCLASSIFIED S, E CURITY CLASSIFICATION OF THIS PAGE-" REPORT DOCUMENTATION...ACCESSION NO. 11. TITLE (Include Security Classification) . Veta -Analysis of Human Factors Engineering Studies Comparing Individual Differences, Practice...Background C Opportunity D Significance E History III. PHASE I FINAL REPORT A Literature Review B Formal Analysis C Results D Implications for Phase II IV
The Effect of Laminar Flow on Rotor Hover Performance
NASA Technical Reports Server (NTRS)
Overmeyer, Austin D.; Martin, Preston B.
2017-01-01
The topic of laminar flow effects on hover performance is introduced with respect to some historical efforts where laminar flow was either measured or attempted. An analysis method is outlined using combined blade element, momentum method coupled to an airfoil analysis method, which includes the full e(sup N) transition model. The analysis results compared well with the measured hover performance including the measured location of transition on both the upper and lower blade surfaces. The analysis method is then used to understand the upper limits of hover efficiency as a function of disk loading. The impact of laminar flow is higher at low disk loading, but significant improvement in terms of power loading appears possible even up to high disk loading approaching 20 ps f. A optimum planform design equation is derived for cases of zero profile drag and finite drag levels. These results are intended to be a guide for design studies and as a benchmark to compare higher fidelity analysis results. The details of the analysis method are given to enable other researchers to use the same approach for comparison to other approaches.
Use of error grid analysis to evaluate acceptability of a point of care prothrombin time meter.
Petersen, John R; Vonmarensdorf, Hans M; Weiss, Heidi L; Elghetany, M Tarek
2010-02-01
Statistical methods (linear regression, correlation analysis, etc.) are frequently employed in comparing methods in the central laboratory (CL). Assessing acceptability of point of care testing (POCT) equipment, however, is more difficult because statistically significant biases may not have an impact on clinical care. We showed how error grid (EG) analysis can be used to evaluate POCT PT INR with the CL. We compared results from 103 patients seen in an anti-coagulation clinic that were on Coumadin maintenance therapy using fingerstick samples for POCT (Roche CoaguChek XS and S) and citrated venous blood samples for CL (Stago STAR). To compare clinical acceptability of results we developed an EG with zones A, B, C and D. Using 2nd order polynomial equation analysis, POCT results highly correlate with the CL for CoaguChek XS (R(2)=0. 955) and CoaguChek S (R(2)=0. 93), respectively but does not indicate if POCT results are clinically interchangeable with the CL. Using EG it is readily apparent which levels can be considered clinically identical to the CL despite analytical bias. We have demonstrated the usefulness of EG in determining acceptability of POCT PT INR testing and how it can be used to determine cut-offs where differences in POCT results may impact clinical care. Copyright 2009 Elsevier B.V. All rights reserved.
The Empirical Review of Meta-Analysis Published in Korea
ERIC Educational Resources Information Center
Park, Sunyoung; Hong, Sehee
2016-01-01
Meta-analysis is a statistical method that is increasingly utilized to combine and compare the results of previous primary studies. However, because of the lack of comprehensive guidelines for how to use meta-analysis, many meta-analysis studies have failed to consider important aspects, such as statistical programs, power analysis, publication…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
... determined that the quantitative analysis of the energy consumption of buildings built to Standard 90.1-2007... Determination 3. Public Comments Regarding the Preliminary Determination II. Summary of the Comparative Analysis... Analysis B. Quantitative Analysis 1. Discussion of Whole Building Energy Analysis 2. Results of Whole...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Hayeon, E-mail: kimh2@upmc.edu; Gill, Beant; Beriwal, Sushil
Purpose: To conduct a cost-effectiveness analysis to determine whether stereotactic body radiation therapy (SBRT) is a cost-effective therapy compared with radiofrequency ablation (RFA) for patients with unresectable colorectal cancer (CRC) liver metastases. Methods and Materials: A cost-effectiveness analysis was conducted using a Markov model and 1-month cycle over a lifetime horizon. Transition probabilities, quality of life utilities, and costs associated with SBRT and RFA were captured in the model on the basis of a comprehensive literature review and Medicare reimbursements in 2014. Strategies were compared using the incremental cost-effectiveness ratio, with effectiveness measured in quality-adjusted life years (QALYs). To account formore » model uncertainty, 1-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay threshold of $100,000 per QALY gained. Results: In base case analysis, treatment costs for 3 fractions of SBRT and 1 RFA procedure were $13,000 and $4397, respectively. Median survival was assumed the same for both strategies (25 months). The SBRT costs $8202 more than RFA while gaining 0.05 QALYs, resulting in an incremental cost-effectiveness ratio of $164,660 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of median survival from both treatments. Stereotactic body radiation therapy was economically reasonable if better survival was presumed (>1 month gain) or if used for large tumors (>4 cm). Conclusions: If equal survival is assumed, SBRT is not cost-effective compared with RFA for inoperable colorectal liver metastases. However, if better local control leads to small survival gains with SBRT, this strategy becomes cost-effective. Ideally, these results should be confirmed with prospective comparative data.« less
Savasoglu, Kaan; Payzin, Kadriye Bahriye; Ozdemirkiran, Fusun; Berber, Belgin
2015-08-01
To determine the use of the Quantitative Real Time PCR (RQ-PCR) assay follow-up with Chronic Myeloid Leukemia (CML) patients. Cross-sectional observational. Izmir Ataturk Education and Research Hospital, Izmir, Turkey, from 2009 to 2013. Cytogenetic, FISH, RQ-PCR test results from 177 CMLpatients' materials selected between 2009 - 2013 years was set up for comparison analysis. Statistical analysis was performed to compare between FISH, karyotype and RQ-PCR results of the patients. Karyotyping and FISH specificity and sensitivity rates determined by ROC analysis compared with RQ-PCR results. Chi-square test was used to compare test failure rates. Sensitivity and specificity values were determined for karyotyping 17.6 - 98% (p=0.118, p > 0.05) and for FISH 22.5 - 96% (p=0.064, p > 0.05) respectively. FISH sensitivity was slightly higher than karyotyping but there was calculated a strong correlation between them (p < 0.001). RQ-PCR test failure rate did not correlate with other two tests (p > 0.05); however, karyotyping and FISH test failure rate was statistically significant (p < 0.001). Besides, the situation needed for karyotype analysis, RQ-PCR assay can be used alone in the follow-up of CMLdisease.
Posttest RELAP4 analysis of LOFT experiment L1-4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grush, W.H.; Holmstrom, H.L.O.
Results of posttest analysis of LOFT loss-of-coolant experiment L1-4 with the RELAP4 code are presented. The results are compared with the pretest prediction and the test data. Differences between the RELAP4 model used for this analysis and that used for the pretest prediction are in the areas of initial conditions, nodalization, emergency core cooling system, broken loop hot leg, and steam generator secondary. In general, these changes made only minor improvement in the comparison of the analytical results to the data. Also presented are the results of a limited study of LOFT downcomer modeling which compared the performance of themore » conventional single downcomer model with that of the new split downcomer model. A RELAP4 sensitivity calculation with artificially elevated emergency core coolant temperature was performed to highlight the need for an ECC mixing model in RELAP4.« less
Analysis of Square Cup Deep-Drawing Test of Pure Titanium
NASA Astrophysics Data System (ADS)
Ogawa, Takaki; Ma, Ninshu; Ueyama, Minoru; Harada, Yasunori
2016-08-01
The prediction of formability of titunium is more difficult than steels since its strong anisotropy. If computer simulation can estimate the formability of titanium, we can select the optimal forming conditions. The purpose of this study was to acquire knowledge for the formability prediction by the computer simulation of the square cup deep-drawing of pure titanium. In this paper, the results of FEM analsis of pure titanium were compared with the experimental results to examine the analysis validity. We analyzed the formability of deepdrawing square cup of titanium by the FEM using solid elements. Compared the analysis results with the experimental results such as the forming shape, the punch load, and the thickness, the validity was confirmed. Further, through analyzing the change of the thickness around the forming corner, it was confirmed that the thickness increased to its maximum value during forming process at the stroke of 35mm more than the maximum stroke.
NASA Technical Reports Server (NTRS)
Rapp, R. H.
1974-01-01
Results have been obtained for the solution of 184 15-deg equal-area blocks directly from the analysis of satellite orbits, and from a combination of the satellite results with terrestrial gravity material. This test computation, made to verify the method, used 17,632 optical observations from ten satellites in 29 arcs averaging in length seven days. Analysis of the satellite results were made by comparing the solved for anomalies with the terrestrial anomaly set, and by developing the solved for anomalies into potential coefficients which were compared to the GEM 3 set of potential coefficients to degree 12. These comparisons indicated improvement in each solution as more arcs were added. The programs used in this solution can easily be used to solve for smaller size blocks and handle additional data types. The only limitation will be computer core availability and computer time.
Response analysis of an automobile shipping container
NASA Technical Reports Server (NTRS)
Hua, L.; Lee, S. H.; Johnstone, B.
1973-01-01
The design and development of automobile shipping containers to reduce enroute damage are discussed. Vibration tests were conducted to determine the system structural integrity. A dynamic analysis was made using NASTRAN and the results of the test and the analysis are compared.
Glaucoma diagnosis by mapping macula with Fourier domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Tan, Ou; Lu, Ake; Chopra, Vik; Varma, Rohit; Hiroshi, Ishikawa; Schuman, Joel; Huang, David
2008-03-01
A new image segmentation method was developed to detect macular retinal sub-layers boundary on newly-developed Fourier-Domain Optical Coherence Tomography (FD-OCT) with macular grid scan pattern. The segmentation results were used to create thickness map of macular ganglion cell complex (GCC), which contains the ganglion cell dendrites, cell bodies and axons. Overall average and several pattern analysis parameters were defined on the GCC thickness map and compared for the diagnosis of glaucoma. Intraclass correlation (ICC) is used to compare the reproducibility of the parameters. Area under receiving operative characteristic curve (AROC) was calculated to compare the diagnostic power. The result is also compared to the output of clinical time-domain OCT (TD-OCT). We found that GCC based parameters had good repeatability and comparable diagnostic power with circumpapillary nerve fiber layer (cpNFL) thickness. Parameters based on pattern analysis can increase the diagnostic power of GCC macular mapping.
EDGAR: A software framework for the comparative analysis of prokaryotic genomes
Blom, Jochen; Albaum, Stefan P; Doppmeier, Daniel; Pühler, Alfred; Vorhölter, Frank-Jörg; Zakrzewski, Martha; Goesmann, Alexander
2009-01-01
Background The introduction of next generation sequencing approaches has caused a rapid increase in the number of completely sequenced genomes. As one result of this development, it is now feasible to analyze large groups of related genomes in a comparative approach. A main task in comparative genomics is the identification of orthologous genes in different genomes and the classification of genes as core genes or singletons. Results To support these studies EDGAR – "Efficient Database framework for comparative Genome Analyses using BLAST score Ratios" – was developed. EDGAR is designed to automatically perform genome comparisons in a high throughput approach. Comparative analyses for 582 genomes across 75 genus groups taken from the NCBI genomes database were conducted with the software and the results were integrated into an underlying database. To demonstrate a specific application case, we analyzed ten genomes of the bacterial genus Xanthomonas, for which phylogenetic studies were awkward due to divergent taxonomic systems. The resultant phylogeny EDGAR provided was consistent with outcomes from traditional approaches performed recently and moreover, it was possible to root each strain with unprecedented accuracy. Conclusion EDGAR provides novel analysis features and significantly simplifies the comparative analysis of related genomes. The software supports a quick survey of evolutionary relationships and simplifies the process of obtaining new biological insights into the differential gene content of kindred genomes. Visualization features, like synteny plots or Venn diagrams, are offered to the scientific community through a web-based and therefore platform independent user interface , where the precomputed data sets can be browsed. PMID:19457249
DOT National Transportation Integrated Search
2010-05-01
This report documents the results of a strategic job analysis that examined the job tasks and knowledge, skills, abilities, and other characteristics (KSAOs) needed to perform the job of a work schedule manager. The strategic job analysis compared in...
DOT National Transportation Integrated Search
2010-05-01
This report documents the results of a strategic job analysis that examined the job tasks and knowledge, skills, abilities, and other characteristics (KSAOs) needed to perform the job of a work schedule manager. The strategic job analysis compared in...
NASA Technical Reports Server (NTRS)
Mausel, P. W.; Todd, W. J.; Baumgardner, M. F.
1976-01-01
A successful application of state-of-the-art remote sensing technology in classifying an urban area into its broad land use classes is reported. This research proves that numerous urban features are amenable to classification using ERTS multispectral data automatically processed by computer. Furthermore, such automatic data processing (ADP) techniques permit areal analysis on an unprecedented scale with a minimum expenditure of time. Also, classification results obtained using ADP procedures are consistent, comparable, and replicable. The results of classification are compared with the proposed U. S. G. S. land use classification system in order to determine the level of classification that is feasible to obtain through ERTS analysis of metropolitan areas.
Experimental and analytical assessment of the thermal behavior of spiral bevel gears
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.; Kicher, Thomas P.
1995-01-01
An experimental and analytical study of spiral bevel gears operating in an aerospace environment has been performed. Tests were conducted within a closed loop test stand at NASA Lewis Research Center. Tests were conducted to 537 kW (720 hp) at 14,400 rpm. The effects of various operating conditions on spiral bevel gear steady state and transient temperature are presented. Also, a three-dimensional analysis of the thermal behavior was conducted using a nonlinear finite element analysis computer code. The analysis was compared to the experimental results attained in this study. The results agreed well with each other for the cases compared and were no more than 10 percent different in magnitude.
The Comparison of Turkish Students' PISA Achievement Levels by Year via Data Envelopment Analysis
ERIC Educational Resources Information Center
Yalçin, Seher; Tavsancil, Ezel
2014-01-01
This research aimed to determine the relative efficiency of the types of school common to three administrations of the PISA (2003-2006-2009) by comparing their results, along with the activities that are to be performed for inefficient school types and changes in the efficiency value of the school types by year. The comparative analysis was based…
van der Krieke, Lian; Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith Gm; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-08-07
Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher's tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use.
A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR
A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...
Pichai, Saravanan; Rajesh, M; Reddy, Naveen; Adusumilli, Gopinath; Reddy, Jayaprakash; Joshi, Bhavana
2014-01-01
Background: Skeletal maturation is an integral part of individual pattern of growth and development and is a continuous process. Peak growth velocity in standing height is the most valid representation of the rate of overall skeletal growth. Ossification changes of hand wrist and cervical vertebrae are the reliable indicators of growth status of individual. The objective of this study was to compare skeletal maturation as measured by hand wrist bone analysis and cervical vertebral analysis. Materials and Methods: Hand wrist radiographs and lateral cephalograms of 72 subjects aged between 7 and 16 years both male and female from the patients visiting Department of Orthodontics and Dentofacial Orthopedics, R.V. Dental College and Hospital. The 9 stages were reduced to 5 stages to compare with cervical vertebral maturation stage by Baccetti et al. The Bjork, Grave and Brown stages were reduced to six intervals to compare with cervical vertebral maturational index (CVMI) staging by Hassel and Farman. These measurements were then compared with the hand wrist bone analysis, and the results were statistically analyzed using the Mann–Whitney test. Results: There was no significant difference between the hand wrist analysis and the two different cervical vertebral analyses for assessing skeletal maturation. There was no significant difference between the two cervical vertebral analyses, but the CVMI method, which is visual method is less time consuming. Conclusion: Vertebral analysis on a lateral cephalogram is as valid as the hand wrist bone analysis with the advantage of reducing the radiation exposure of growing subjects. PMID:25395791
McEvoy, Eamon; Donegan, Sheila; Power, Joe; Altria, Kevin
2007-05-09
A rapid and efficient oil-in-water microemulsion liquid chromatographic method has been optimised and validated for the analysis of paracetamol in a suppository formulation. Excellent linearity, accuracy, precision and assay results were obtained. Lengthy sample pre-treatment/extraction procedures were eliminated due to the solubilising power of the microemulsion and rapid analysis times were achieved. The method was optimised to achieve rapid analysis time and relatively high peak efficiencies. A standard microemulsion composition of 33 g SDS, 66 g butan-1-ol, 8 g n-octane in 1l of 0.05% TFA modified with acetonitrile has been shown to be suitable for the rapid analysis of paracetamol in highly hydrophobic preparations under isocratic conditions. Validated assay results and overall analysis time of the optimised method was compared to British Pharmacopoeia reference methods. Sample preparation and analysis times for the MELC analysis of paracetamol in a suppository were extremely rapid compared to the reference method and similar assay results were achieved. A gradient MELC method using the same microemulsion has been optimised for the resolution of paracetamol and five of its related substances in approximately 7 min.
Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.
Plappert-Helbig, Ulla; Guérard, Melanie
2015-12-01
To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.
Crawford, Cindy; Boyd, Courtney; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Yang, EunMee; Zhang, Weimin; Buckenmaier, Chester; Buckenmaier, Pamela; Cambron, Jerrilyn; Deery, Christopher; Schwartz, Jan; Werner, Ruth; Whitridge, Pete
2016-01-01
Abstract Purpose Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life outcomes across all pain populations. Methods Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Results Sixty high quality and seven low quality studies were included in the review. Results demonstrate massage therapy effectively treats pain compared to sham [standardized mean difference (SMD) = −.44], no treatment (SMD = −1.14), and active (SMD = −0.26) comparators. Compared to active comparators, massage therapy was also beneficial for treating anxiety (SMD = −0.57) and health-related quality of life (SMD = 0.14). Conclusion Based on the evidence, massage therapy, compared to no treatment, should be strongly recommended as a pain management option. Massage therapy is weakly recommended for reducing pain, compared to other sham or active comparators, and improving mood and health-related quality of life, compared to other active comparators. Massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option are discussed. PMID:27165971
Dietary pattern analysis: a comparison between matched vegetarian and omnivorous subjects
2013-01-01
Background Dietary pattern analysis, based on the concept that foods eaten together are as important as a reductive methodology characterized by a single food or nutrient analysis, has emerged as an alternative approach to study the relation between nutrition and disease. The aim of the present study was to compare nutritional intake and the results of dietary pattern analysis in properly matched vegetarian and omnivorous subjects. Methods Vegetarians (n = 69) were recruited via purposeful sampling and matched non-vegetarians (n = 69) with same age, gender, health and lifestyle characteristics were searched for via convenience sampling. Two dietary pattern analysis methods, the Healthy Eating Index-2010 (HEI-2010) and the Mediterranean Diet Score (MDS) were calculated and analysed in function of the nutrient intake. Results Mean total energy intake was comparable between vegetarians and omnivorous subjects (p > 0.05). Macronutrient analysis revealed significant differences between the mean values for vegetarians and omnivorous subjects (absolute and relative protein and total fat intake were significantly lower in vegetarians, while carbohydrate and fibre intakes were significantly higher in vegetarians than in omnivorous subjects). The HEI and MDS were significantly higher for the vegetarians (HEI = 53.8.1 ± 11.2; MDS = 4.3 ± 1.3) compared to the omnivorous subjects (HEI = 46.4 ± 15.3; MDS = 3.8 ± 1.4). Conclusions Our results indicate a more nutrient dense pattern, closer to the current dietary recommendations for the vegetarians compared to the omnivorous subjects. Both indexing systems were able to discriminate between the vegetarians and the non-vegetarians with higher scores for the vegetarian subjects. PMID:23758767
2012-01-01
Background To demonstrate the use of risk-benefit analysis for comparing multiple competing interventions in the absence of randomized trials, we applied this approach to the evaluation of five anticoagulants to prevent thrombosis in patients undergoing orthopedic surgery. Methods Using a cost-effectiveness approach from a clinical perspective (i.e. risk benefit analysis) we compared thromboprophylaxis with warfarin, low molecular weight heparin, unfractionated heparin, fondaparinux or ximelagatran in patients undergoing major orthopedic surgery, with sub-analyses according to surgery type. Proportions and variances of events defining risk (major bleeding) and benefit (thrombosis averted) were obtained through a meta-analysis and used to define beta distributions. Monte Carlo simulations were conducted and used to calculate incremental risks, benefits, and risk-benefit ratios. Finally, net clinical benefit was calculated for all replications across a range of risk-benefit acceptability thresholds, with a reference range obtained by estimating the case fatality rate - ratio of thrombosis to bleeding. Results The analysis showed that compared to placebo ximelagatran was superior to other options but final results were influenced by type of surgery, since ximelagatran was superior in total knee replacement but not in total hip replacement. Conclusions Using simulation and economic techniques we demonstrate a method that allows comparing multiple competing interventions in the absence of randomized trials with multiple arms by determining the option with the best risk-benefit profile. It can be helpful in clinical decision making since it incorporates risk, benefit, and personal risk acceptance. PMID:22233221
Ibarra, Alvin; Astbury, Nerys M; Olli, Kaisa; Alhoniemi, Esa; Tiihonen, Kirsti
2016-01-14
Subjective feelings of appetite are measured using visual analogue scales (VAS) in controlled trials. However, the methods used to analyze VAS during the Satiation (pre- to post-meal) and Satiety (post-meal to subsequent meal) periods vary broadly, making it difficult to compare results amongst independent studies testing the same product. This review proposes a methodology to analyze VAS during both the Satiation and Satiety periods, allowing us to compare results in a meta-analysis. A methodology to express VAS results as incremental areas under the curve (iAUC) for both the Satiation and Satiety periods is proposed using polydextrose as a case study. Further, a systematic review and meta-analysis on subjective feelings of appetite was conducted following the PRISMA methodology. Meta-analyses were expressed as Standardized Mean Difference (SMD). Seven studies were included in the meta-analysis. There were important differences in the methods used to analyze appetite ratings amongst these studies. The separate subjective feelings of appetite reported were Hunger, Satisfaction, Fullness, Prospective Food Consumption, and the Desire to Eat. The method proposed here allowed the results of the different studies to be homogenized. The meta-analysis showed that Desire to Eat during the Satiation period favors polydextrose for the reduction of this subjective feeling of appetite (SMD = 0.24, I² < 0.01, p = 0.018); this effect was also significant in the sub-analysis by sex for the male population (SMD = 0.35, I² < 0.01, p = 0.015). There were no other significant results. It is possible to compare VAS results from separate studies. The assessment of iAUC for both the Satiation and Satiety periods generates results of homogeneous magnitudes. This case study demonstrates, for the first time, that polydextrose reduces the Desire to Eat during the Satiation period. This may explain, at least in part, the observed effects of polydextrose on the reduction of levels of energy intake at subsequent meals.
Plasma cell quantification in bone marrow by computer-assisted image analysis.
Went, P; Mayer, S; Oberholzer, M; Dirnhofer, S
2006-09-01
Minor and major criteria for the diagnosis of multiple meloma according to the definition of the WHO classification include different categories of the bone marrow plasma cell count: a shift from the 10-30% group to the > 30% group equals a shift from a minor to a major criterium, while the < 10% group does not contribute to the diagnosis. Plasma cell fraction in the bone marrow is therefore critical for the classification and optimal clinical management of patients with plasma cell dyscrasias. The aim of this study was (i) to establish a digital image analysis system able to quantify bone marrow plasma cells and (ii) to evaluate two quantification techniques in bone marrow trephines i.e. computer-assisted digital image analysis and conventional light-microscopic evaluation. The results were compared regarding inter-observer variation of the obtained results. Eighty-seven patients, 28 with multiple myeloma, 29 with monoclonal gammopathy of undetermined significance, and 30 with reactive plasmocytosis were included in the study. Plasma cells in H&E- and CD138-stained slides were quantified by two investigators using light-microscopic estimation and computer-assisted digital analysis. The sets of results were correlated with rank correlation coefficients. Patients were categorized according to WHO criteria addressing the plasma cell content of the bone marrow (group 1: 0-10%, group 2: 11-30%, group 3: > 30%), and the results compared by kappa statistics. The degree of agreement in CD138-stained slides was higher for results obtained using the computer-assisted image analysis system compared to light microscopic evaluation (corr.coeff. = 0.782), as was seen in the intra- (corr.coeff. = 0.960) and inter-individual results correlations (corr.coeff. = 0.899). Inter-observer agreement for categorized results (SM/PW: kappa 0.833) was in a high range. Computer-assisted image analysis demonstrated a higher reproducibility of bone marrow plasma cell quantification. This might be of critical importance for diagnosis, clinical management and prognostics when plasma cell numbers are low, which makes exact quantifications difficult.
A Comparison of Component and Factor Patterns: A Monte Carlo Approach.
ERIC Educational Resources Information Center
Velicer, Wayne F.; And Others
1982-01-01
Factor analysis, image analysis, and principal component analysis are compared with respect to the factor patterns they would produce under various conditions. The general conclusion that is reached is that the three methods produce results that are equivalent. (Author/JKS)
GoPros™ as an underwater photogrammetry tool for citizen science
David, Peter A.; Dupont, Sally F.; Mathewson, Ciaran P.; O’Neill, Samuel J.; Powell, Nicholas N.; Williamson, Jane E.
2016-01-01
Citizen science can increase the scope of research in the marine environment; however, it suffers from necessitating specialized training and simplified methodologies that reduce research output. This paper presents a simplified, novel survey methodology for citizen scientists, which combines GoPro imagery and structure from motion to construct an ortho-corrected 3D model of habitats for analysis. Results using a coral reef habitat were compared to surveys conducted with traditional snorkelling methods for benthic cover, holothurian counts, and coral health. Results were comparable between the two methods, and structure from motion allows the results to be analysed off-site for any chosen visual analysis. The GoPro method outlined in this study is thus an effective tool for citizen science in the marine environment, especially for comparing changes in coral cover or volume over time. PMID:27168973
GoPros™ as an underwater photogrammetry tool for citizen science.
Raoult, Vincent; David, Peter A; Dupont, Sally F; Mathewson, Ciaran P; O'Neill, Samuel J; Powell, Nicholas N; Williamson, Jane E
2016-01-01
Citizen science can increase the scope of research in the marine environment; however, it suffers from necessitating specialized training and simplified methodologies that reduce research output. This paper presents a simplified, novel survey methodology for citizen scientists, which combines GoPro imagery and structure from motion to construct an ortho-corrected 3D model of habitats for analysis. Results using a coral reef habitat were compared to surveys conducted with traditional snorkelling methods for benthic cover, holothurian counts, and coral health. Results were comparable between the two methods, and structure from motion allows the results to be analysed off-site for any chosen visual analysis. The GoPro method outlined in this study is thus an effective tool for citizen science in the marine environment, especially for comparing changes in coral cover or volume over time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, T.F.; Thorne, P.G.; Myers, K.F.
Salting-out solvent extraction (SOE) was compared with cartridge and membrane solid-phase extraction (SPE) for preconcentration of nitroaromatics, nitramines, and aminonitroaromatics prior to determination by reversed-phase high-performance liquid chromatography. The solid phases used were manufacturer-cleaned materials, Porapak RDX for the cartridge method and Empore SDB-RPS for the membrane method. Thirty-three groundwater samples from the Naval Surface Warfare Center, Crane, Indiana, were analyzed using the direct analysis protocol specified in SW846 Method 8330, and the results were compared with analyses conducted after preconcentration using SOE with acetonitrile, cartridge-based SPE, and membrane-based SPE. For high-concentration samples, analytical results from the three preconcentration techniquesmore » were compared with results from the direct analysis protocol; good recovery of all target analytes was achieved by all three pre-concentration methods. For low-concentration samples, results from the two SPE methods were correlated with results from the SOE method; very similar data was obtained by the SOE and SPE methods, even at concentrations well below 1 microgram/L.« less
[Phoneme analysis and phoneme discrimination of juvenile speech therapy school students].
Franz, S; Rosanowski, F; Eysholdt, U; Hoppe, U
2011-05-01
Phoneme analysis and phoneme discrimination, important factors in acquiring spoken and written language, have been evaluated in juvenile speech therapy school students. The results have been correlated with the results of a school achievement test. The following questions were of interest: Do students in the lower verbal skill segment show pathological phoneme analysis and phoneme discrimination skills? Do the results of the school achievement test differ from the results by students visiting German "Hauptschule"? How does phoneme analysis and phoneme discrimination performance correlate to other tested parameters? 74 students of a speech therapy school ranging from 7 (th) to 9 (th) grade were examined (ages 12;10-17;04) with the Heidelberg Phoneme Discrimination Test H-LAD and the school achievement test "Prüfsystem für Schul- und Bildungsberatung PSB-R 6-13". Compared to 4 (th) graders the juvenile speech therapy school students showed worse results in the H-LAD test with good differentiation in the lower measuring range. In the PSB-R 6-13 test the examined students did worse compared to students visiting German "Hauptschule" for all grades except 9 (th) grade. Comparing H-LAD and PSB-R 6-13 shows a significant correlation for the sub-tests covering language competence and intelligence but not for the concentration tests. Pathological phoneme analysis and phoneme discrimination skills suggest elevated need for counseling, but this needs to corroborated through additional linguistic parameters and measuring non-verbal intelligence. Further trails are needed in order to clarify whether the results can lead to sophisticated therapy algorithms for educational purposes. © Georg Thieme Verlag KG Stuttgart · New York.
Comparison of variance estimators for meta-analysis of instrumental variable estimates
Schmidt, AF; Hingorani, AD; Jefferis, BJ; White, J; Groenwold, RHH; Dudbridge, F
2016-01-01
Abstract Background: Mendelian randomization studies perform instrumental variable (IV) analysis using genetic IVs. Results of individual Mendelian randomization studies can be pooled through meta-analysis. We explored how different variance estimators influence the meta-analysed IV estimate. Methods: Two versions of the delta method (IV before or after pooling), four bootstrap estimators, a jack-knife estimator and a heteroscedasticity-consistent (HC) variance estimator were compared using simulation. Two types of meta-analyses were compared, a two-stage meta-analysis pooling results, and a one-stage meta-analysis pooling datasets. Results: Using a two-stage meta-analysis, coverage of the point estimate using bootstrapped estimators deviated from nominal levels at weak instrument settings and/or outcome probabilities ≤ 0.10. The jack-knife estimator was the least biased resampling method, the HC estimator often failed at outcome probabilities ≤ 0.50 and overall the delta method estimators were the least biased. In the presence of between-study heterogeneity, the delta method before meta-analysis performed best. Using a one-stage meta-analysis all methods performed equally well and better than two-stage meta-analysis of greater or equal size. Conclusions: In the presence of between-study heterogeneity, two-stage meta-analyses should preferentially use the delta method before meta-analysis. Weak instrument bias can be reduced by performing a one-stage meta-analysis. PMID:27591262
NASA Astrophysics Data System (ADS)
Li, Jiangui; Wang, Junhua; Zhigang, Zhao; Yan, Weili
2012-04-01
In this paper, analytical analysis of the permanent magnet vernier (PMV) is presented. The key is to analytically solve the governing Laplacian/quasi-Poissonian field equations in the motor regions. By using the time-stepping finite element method, the analytical method is verified. Hence, the performances of the PMV machine are quantitatively compared with that of the analytical results. The analytical results agree well with the finite element method results. Finally, the experimental results are given to further show the validity of the analysis.
Modeling and Analysis of Space Based Transceivers
NASA Technical Reports Server (NTRS)
Reinhart, Richard C.; Liebetreu, John; Moore, Michael S.; Price, Jeremy C.; Abbott, Ben
2005-01-01
This paper presents the tool chain, methodology, and initial results of a study to provide a thorough, objective, and quantitative analysis of the design alternatives for space Software Defined Radio (SDR) transceivers. The approach taken was to develop a set of models and tools for describing communications requirements, the algorithm resource requirements, the available hardware, and the alternative software architectures, and generate analysis data necessary to compare alternative designs. The Space Transceiver Analysis Tool (STAT) was developed to help users identify and select representative designs, calculate the analysis data, and perform a comparative analysis of the representative designs. The tool allows the design space to be searched quickly while permitting incremental refinement in regions of higher payoff.
Modeling and Analysis of Space Based Transceivers
NASA Technical Reports Server (NTRS)
Moore, Michael S.; Price, Jeremy C.; Abbott, Ben; Liebetreu, John; Reinhart, Richard C.; Kacpura, Thomas J.
2007-01-01
This paper presents the tool chain, methodology, and initial results of a study to provide a thorough, objective, and quantitative analysis of the design alternatives for space Software Defined Radio (SDR) transceivers. The approach taken was to develop a set of models and tools for describing communications requirements, the algorithm resource requirements, the available hardware, and the alternative software architectures, and generate analysis data necessary to compare alternative designs. The Space Transceiver Analysis Tool (STAT) was developed to help users identify and select representative designs, calculate the analysis data, and perform a comparative analysis of the representative designs. The tool allows the design space to be searched quickly while permitting incremental refinement in regions of higher payoff.
Performance Analysis of Hybrid Electric Vehicle over Different Driving Cycles
NASA Astrophysics Data System (ADS)
Panday, Aishwarya; Bansal, Hari Om
2017-02-01
Article aims to find the nature and response of a hybrid vehicle on various standard driving cycles. Road profile parameters play an important role in determining the fuel efficiency. Typical parameters of road profile can be reduced to a useful smaller set using principal component analysis and independent component analysis. Resultant data set obtained after size reduction may result in more appropriate and important parameter cluster. With reduced parameter set fuel economies over various driving cycles, are ranked using TOPSIS and VIKOR multi-criteria decision making methods. The ranking trend is then compared with the fuel economies achieved after driving the vehicle over respective roads. Control strategy responsible for power split is optimized using genetic algorithm. 1RC battery model and modified SOC estimation method are considered for the simulation and improved results compared with the default are obtained.
Disutility analysis of oil spills: graphs and trends.
Ventikos, Nikolaos P; Sotiropoulos, Foivos S
2014-04-15
This paper reports the results of an analysis of oil spill cost data assembled from a worldwide pollution database that mainly includes data from the International Oil Pollution Compensation Fund. The purpose of the study is to analyze the conditions of marine pollution accidents and the factors that impact the costs of oil spills worldwide. The accidents are classified into categories based on their characteristics, and the cases are compared using charts to show how the costs are affected under all conditions. This study can be used as a helpful reference for developing a detailed statistical model that is capable of reliably and realistically estimating the total costs of oil spills. To illustrate the differences identified by this statistical analysis, the results are compared with the results of previous studies, and the findings are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.
Trujillo, Carlos; Garcia-Sucerquia, Jorge
2015-06-01
A comparative analysis of the performance of the modified enclosed energy (MEE) method for self-focusing holograms recorded with digital lensless holographic microscopy is presented. Notwithstanding the MEE analysis previously published, no extended analysis of its performance has been reported. We have tested the MEE in terms of the minimum axial distance allowed between the set of reconstructed holograms to search for the focal plane and the elapsed time to obtain the focused image. These parameters have been compared with those for some of the already reported methods in the literature. The MEE achieves better results in terms of self-focusing quality but at a higher computational cost. Despite its longer processing time, the method remains within a time frame to be technologically attractive. Modeled and experimental holograms have been utilized in this work to perform the comparative study.
McAlearney, Ann Scheck; Walker, Daniel; Moss, Alexandra DeNardis; Bickell, Nina A.
2015-01-01
Background Qualitative Comparative Analysis (QCA) is a methodology created to address causal complexity in social sciences research by preserving the objectivity of quantitative data analysis without losing detail inherent in qualitative research. However, its use in health services research (HSR) is limited, and questions remain about its application in this context. Objective To explore the strengths and weaknesses of using QCA for HSR. Research Design Using data from semi-structured interviews conducted as part of a multiple case study about adjuvant treatment underuse among underserved breast cancer patients, findings were compared using qualitative approaches with and without QCA to identify strengths, challenges, and opportunities presented by QCA. Subjects Ninety administrative and clinical key informants interviewed across ten NYC area safety net hospitals. Measures Transcribed interviews were coded by three investigators using an iterative and interactive approach. Codes were calibrated for QCA, as well as examined using qualitative analysis without QCA. Results Relative to traditional qualitative analysis, QCA strengths include: (1) addressing causal complexity, (2) results presentation as pathways as opposed to a list, (3) identification of necessary conditions, (4) the option of fuzzy-set calibrations, and (5) QCA-specific parameters of fit that allow researchers to compare outcome pathways. Weaknesses include: (1) few guidelines and examples exist for calibrating interview data, (2) not designed to create predictive models, and (3) unidirectionality. Conclusions Through its presentation of results as pathways, QCA can highlight factors most important for production of an outcome. This strength can yield unique benefits for HSR not available through other methods. PMID:26908085
Automated daily quality control analysis for mammography in a multi-unit imaging center.
Sundell, Veli-Matti; Mäkelä, Teemu; Meaney, Alexander; Kaasalainen, Touko; Savolainen, Sauli
2018-01-01
Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.
Chellali, Amine; Schwaitzberg, Steven D.; Jones, Daniel B.; Romanelli, John; Miller, Amie; Rattner, David; Roberts, Kurt E.; Cao, Caroline G.L.
2014-01-01
Background NOTES is an emerging technique for performing surgical procedures, such as cholecystectomy. Debate about its real benefit over the traditional laparoscopic technique is on-going. There have been several clinical studies comparing NOTES to conventional laparoscopic surgery. However, no work has been done to compare these techniques from a Human Factors perspective. This study presents a systematic analysis describing and comparing different existing NOTES methods to laparoscopic cholecystectomy. Methods Videos of endoscopic/laparoscopic views from fifteen live cholecystectomies were analyzed to conduct a detailed task analysis of the NOTES technique. A hierarchical task analysis of laparoscopic cholecystectomy and several hybrid transvaginal NOTES cholecystectomies was performed and validated by expert surgeons. To identify similarities and differences between these techniques, their hierarchical decomposition trees were compared. Finally, a timeline analysis was conducted to compare the steps and substeps. Results At least three variations of the NOTES technique were used for cholecystectomy. Differences between the observed techniques at the substep level of hierarchy and on the instruments being used were found. The timeline analysis showed an increase in time to perform some surgical steps and substeps in NOTES compared to laparoscopic cholecystectomy. Conclusion As pure NOTES is extremely difficult given the current state of development in instrumentation design, most surgeons utilize different hybrid methods – combination of endoscopic and laparoscopic instruments/optics. Results of our hierarchical task analysis yielded an identification of three different hybrid methods to perform cholecystectomy with significant variability amongst them. The varying degrees to which laparoscopic instruments are utilized to assist in NOTES methods appear to introduce different technical issues and additional tasks leading to an increase in the surgical time. The NOTES continuum of invasiveness is proposed here as a classification scheme for these methods, which was used to construct a clear roadmap for training and technology development. PMID:24902811
Annual health examination program, Ames Research Center
NASA Technical Reports Server (NTRS)
Hughes, L.; Ladou, J.
1975-01-01
A cost analysis of a low-volume multiphasic health testing program is presented. The results indicate that unit costs are similar to those of high-volume automated programs. The comparability in unit cost appears to result from the savings in personnel and space requirements of the smaller program as compared with the larger ones.
ERIC Educational Resources Information Center
Marchis, Iuliana
2009-01-01
The results of the Romanian pupils on international tests PISA and TIMSS in Mathematics are below the average. These poor results have many explications. In this article we compare the Mathematics problems given on these international tests with those given on national tests in Romania.
Salvatore, Stefania; Bramness, Jørgen Gustav; Reid, Malcolm J; Thomas, Kevin Victor; Harman, Christopher; Røislien, Jo
2015-01-01
Wastewater-based epidemiology (WBE) is a new methodology for estimating the drug load in a population. Simple summary statistics and specification tests have typically been used to analyze WBE data, comparing differences between weekday and weekend loads. Such standard statistical methods may, however, overlook important nuanced information in the data. In this study, we apply functional data analysis (FDA) to WBE data and compare the results to those obtained from more traditional summary measures. We analysed temporal WBE data from 42 European cities, using sewage samples collected daily for one week in March 2013. For each city, the main temporal features of two selected drugs were extracted using functional principal component (FPC) analysis, along with simpler measures such as the area under the curve (AUC). The individual cities' scores on each of the temporal FPCs were then used as outcome variables in multiple linear regression analysis with various city and country characteristics as predictors. The results were compared to those of functional analysis of variance (FANOVA). The three first FPCs explained more than 99% of the temporal variation. The first component (FPC1) represented the level of the drug load, while the second and third temporal components represented the level and the timing of a weekend peak. AUC was highly correlated with FPC1, but other temporal characteristic were not captured by the simple summary measures. FANOVA was less flexible than the FPCA-based regression, and even showed concordance results. Geographical location was the main predictor for the general level of the drug load. FDA of WBE data extracts more detailed information about drug load patterns during the week which are not identified by more traditional statistical methods. Results also suggest that regression based on FPC results is a valuable addition to FANOVA for estimating associations between temporal patterns and covariate information.
Independent Orbiter Assessment (IOA): Assessment of the nose wheel steering subsystem
NASA Technical Reports Server (NTRS)
Mediavilla, Anthony Scott
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Nose Wheel Steering (NWS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed NASA post 51-L FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter NWS hardware.
Comparison of TRMM and Global Precipitation Climatology Project (GPCP) Precipitation Analyses
NASA Technical Reports Server (NTRS)
Adler, Robert F.; Huffman, George J.; Bolvin, David; Nelkin, Eric; Curtis, Scott
1999-01-01
This paper describes recent results of using Tropical Rainfall Measuring Mission (TRMM) (launched in November 1997) information as the key calibration tool in a merged analysis on a 1 x 1' latitude/longitude monthly scale based on multiple satellite sources and raingauge analyses. The TRMM-based product is compared with the community-based Global Precipitation Climatology Project (GPCP) results. The long-term GPCP analysis is compared to the new TRMM-based analysis which uses the most accurate TRMM information to calibrate the estimates from the Special Sensor Microwave/Imager (SSM/I) and geosynchronous IR observations and merges those estimates together with the TRMM and gauge information to produce accurate rainfall estimates with the increased sampling provided by the combined satellite information. The comparison with TRMM results on a month-to-month basis should clarify the strengths and weaknesses of the long-term GPCP product in the tropics and point to how to improve the monitoring analysis. Preliminary results from the TRMM merged satellite analysis indicates fairly close agreement with the GPCP estimates. The GPCP analysis is done at 2.5 degree latitude/longitude resolution and interpolated to a 1 degree grid for comparison with the TRMM analysis. As expected the same features are evident in both panels, but there are subtle differences in the magnitudes. Focusing on the Pacific Ocean Inter-Tropical Convergence Zone (ITCZ) one can see the TRMM-based estimates having higher peak values and lower values in the ITCZ periphery. These attributes also show up in the statistics, where GPCP>TRMM at low values (below 10 mm/d) and TRMM>GPCP at high values (greater than 15 mm/d). The area in the Indian Ocean which shows consistently higher values of TRMM over GPCP needs to be examined carefully to determine if the lack of geosynchronous data has led to a difference in the two analyses. By the time of the meeting over a year of TRMM products will be available for comparison. Global tropical and regional values will be compared. Both products will be compared to TRMM validation site data over land and water. The results should begin to determine the use of the TRMM estimates in the evaluation of the GPCP analysis.
A Comparative Analysis of User Preferences for for Major Internet Based Education Media in China
ERIC Educational Resources Information Center
Wan, Chunyang; Jiang, Yanqing
2014-01-01
Internet based education media are developing at an amazing rate and being seen as an upstart that will likely take the place of traditional education means worldwide in the future. This paper presents the results of a comparative analysis on user preferences for four major categories of internet-based media used in China. In this paper, we first…
Direct stenting versus balloon predilation: Jury is still out.
Belardi, Jorge A; Albertal, Mariano
2017-08-01
Compared to balloon predilation, direct stenting (DS) shortens procedural time and reduces radiation and contrast exposure. A meta-analysis that included 7 studies comparing these 2 strategies revealed lower adverse event rate with DS. Studies included in the present meta-analysis were mostly observational and utilized first generation drug-eluting stent. Patient and lesion selection may explain these positive results. © 2017 Wiley Periodicals, Inc.
Comparative Study on Romanian School Science Curricula and the Curriculum of TIMSS 2007 Testing
ERIC Educational Resources Information Center
Ciascai, Liliana
2009-01-01
The results of Romanian school students in Science PISA and TIMSS testings have been and continue to be systematically slack. In the present paper we intend to do a comparative analysis of Science curriculum TIMSS 2007 and Romanian Science school curricula of 4th and 8th grades. This analysis, based on Bloom's taxonomy of cognitive domain,…
Lorio, Morgan; Martinson, Melissa; Ferrara, Lisa
2016-01-01
Minimally invasive sacroiliac joint arthrodesis ("MI SIJ fusion") received a Category I CPT ® code (27279) effective January 1, 2015 and was assigned a work relative value unit ("RVU") of 9.03. The International Society for the Advancement of Spine Surgery ("ISASS") conducted a study consisting of a Rasch analysis of two separate surveys of surgeons to assess the accuracy of the assigned work RVU. A survey was developed and sent to ninety-three ISASS surgeon committee members. Respondents were asked to compare CPT ® 27279 to ten other comparator CPT ® codes reflective of common spine surgeries. The survey presented each comparator CPT ® code with its code descriptor as well as the description of CPT ® 27279 and asked respondents to indicate whether CPT ® 27279 was greater, equal, or less in terms of work effort than the comparator code. A second survey was sent to 557 U.S.-based spine surgeon members of ISASS and 241 spine surgeon members of the Society for Minimally Invasive Spine Surgery ("SMISS"). The design of the second survey mirrored that of the first survey except for the use of a broader set of comparator CPT ® codes (27 vs. 10). Using the work RVUs of the comparator codes, a Rasch analysis was performed to estimate the relative difficulty of CPT ® 27279, after which the work RVU of CPT ® 27279 was estimated by regression analysis. Twenty surgeons responded to the first survey and thirty-four surgeons responded to the second survey. The results of the regression analysis of the first survey indicate a work RVU for CPT ® 27279 of 14.36 and the results of the regression analysis of the second survey indicate a work RVU for CPT ® 27279 of 14.1. The Rasch analysis indicates that the current work RVU assigned to CPT ® 27279 is undervalued at 9.03. Averaging the results of the regression analyses of the two surveys indicates a work RVU for CPT ® 27279 of 14.23.
Analysis of Trihalomethanes in Soft Drinks: An Instrumental Analysis Experiment.
ERIC Educational Resources Information Center
Graham, Richard C.; Robertson, John K.
1988-01-01
Describes an experimental procedure for determining trihalomethanes (THMs) in liquids by gas chromatography. Provides recommendations for reactants and supplies to obtain acceptable results. Discusses the analysis of water from various sources: pools, lakes, and drinking water; compares these to three cola drinks. (ML)
NASA Astrophysics Data System (ADS)
Crawford, I.; Ruske, S.; Topping, D. O.; Gallagher, M. W.
2015-11-01
In this paper we present improved methods for discriminating and quantifying primary biological aerosol particles (PBAPs) by applying hierarchical agglomerative cluster analysis to multi-parameter ultraviolet-light-induced fluorescence (UV-LIF) spectrometer data. The methods employed in this study can be applied to data sets in excess of 1 × 106 points on a desktop computer, allowing for each fluorescent particle in a data set to be explicitly clustered. This reduces the potential for misattribution found in subsampling and comparative attribution methods used in previous approaches, improving our capacity to discriminate and quantify PBAP meta-classes. We evaluate the performance of several hierarchical agglomerative cluster analysis linkages and data normalisation methods using laboratory samples of known particle types and an ambient data set. Fluorescent and non-fluorescent polystyrene latex spheres were sampled with a Wideband Integrated Bioaerosol Spectrometer (WIBS-4) where the optical size, asymmetry factor and fluorescent measurements were used as inputs to the analysis package. It was found that the Ward linkage with z-score or range normalisation performed best, correctly attributing 98 and 98.1 % of the data points respectively. The best-performing methods were applied to the BEACHON-RoMBAS (Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H2O, Organics and Nitrogen-Rocky Mountain Biogenic Aerosol Study) ambient data set, where it was found that the z-score and range normalisation methods yield similar results, with each method producing clusters representative of fungal spores and bacterial aerosol, consistent with previous results. The z-score result was compared to clusters generated with previous approaches (WIBS AnalysiS Program, WASP) where we observe that the subsampling and comparative attribution method employed by WASP results in the overestimation of the fungal spore concentration by a factor of 1.5 and the underestimation of bacterial aerosol concentration by a factor of 5. We suggest that this likely due to errors arising from misattribution due to poor centroid definition and failure to assign particles to a cluster as a result of the subsampling and comparative attribution method employed by WASP. The methods used here allow for the entire fluorescent population of particles to be analysed, yielding an explicit cluster attribution for each particle and improving cluster centroid definition and our capacity to discriminate and quantify PBAP meta-classes compared to previous approaches.
Entrance and exit region friction factor models for annular seal analysis. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Elrod, David Alan
1988-01-01
The Mach number definition and boundary conditions in Nelson's nominally-centered, annular gas seal analysis are revised. A method is described for determining the wall shear stress characteristics of an annular gas seal experimentally. Two friction factor models are developed for annular seal analysis; one model is based on flat-plate flow theory; the other uses empirical entrance and exit region friction factors. The friction factor predictions of the models are compared to experimental results. Each friction model is used in an annular gas seal analysis. The seal characteristics predicted by the two seal analyses are compared to experimental results and to the predictions of Nelson's analysis. The comparisons are for smooth-rotor seals with smooth and honeycomb stators. The comparisons show that the analysis which uses empirical entrance and exit region shear stress models predicts the static and stability characteristics of annular gas seals better than the other analyses. The analyses predict direct stiffness poorly.
NASA Astrophysics Data System (ADS)
Salvini, A.; Cattadori, C.; Broggini, C.; Cagnazzo, M.; Ori, Gian Gabriele; Nisi, S.; Borio, A.; Manera, S.
2006-05-01
The platinum metals depleted in the earth's crust are relative to their cosmic abundance; concentration of these elements in sediments may thus indicate influxes of extraterrestrial material. Analysis of these parameters are done easily by Neutron Activation Analysis (NAA) and comparative results with ICP-MS technique show a good match. Results, adjust parameters and limits of this method will be displayed in tables.
Macro elemental analysis of food samples by nuclear analytical technique
NASA Astrophysics Data System (ADS)
Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.
2017-06-01
Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.
Sensitivity of wildlife habitat models to uncertainties in GIS data
NASA Technical Reports Server (NTRS)
Stoms, David M.; Davis, Frank W.; Cogan, Christopher B.
1992-01-01
Decision makers need to know the reliability of output products from GIS analysis. For many GIS applications, it is not possible to compare these products to an independent measure of 'truth'. Sensitivity analysis offers an alternative means of estimating reliability. In this paper, we present a CIS-based statistical procedure for estimating the sensitivity of wildlife habitat models to uncertainties in input data and model assumptions. The approach is demonstrated in an analysis of habitat associations derived from a GIS database for the endangered California condor. Alternative data sets were generated to compare results over a reasonable range of assumptions about several sources of uncertainty. Sensitivity analysis indicated that condor habitat associations are relatively robust, and the results have increased our confidence in our initial findings. Uncertainties and methods described in the paper have general relevance for many GIS applications.
Walters, Glenn D
2014-09-01
An item response theory (IRT) analysis of the Psychological Inventory of Criminal Thinking Styles (PICTS) was performed on 26,831 (19,067 male and 7,764 female) federal probationers and compared with results obtained on 3,266 (3,039 male and 227 female) prisoners from previous research. Despite the fact male and female federal probationers scored significantly lower on the PICTS thinking style scales than male and female prisoners, discrimination and location parameter estimates for the individual PICTS items were comparable across sex and setting. Consistent with the results of a previous IRT analysis conducted on the PICTS, the current results did not support sentimentality as a component of general criminal thinking. Findings from this study indicate that the discriminative power of the individual PICTS items is relatively stable across sex (male, female) and correctional setting (probation, prison) and that the PICTS may be measuring the same criminal thinking construct in male and female probationers and prisoners. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Full core analysis of IRIS reactor by using MCNPX.
Amin, E A; Bashter, I I; Hassan, Nabil M; Mustafa, S S
2016-07-01
This paper describes neutronic analysis for fresh fuelled IRIS (International Reactor Innovative and Secure) reactor by MCNPX code. The analysis included criticality calculations, radial power and axial power distribution, nuclear peaking factor and axial offset percent at the beginning of fuel cycle. The effective multiplication factor obtained by MCNPX code is compared with previous calculations by HELIOS/NESTLE, CASMO/SIMULATE, modified CORD-2 nodal calculations and SAS2H/KENO-V code systems. It is found that k-eff value obtained by MCNPX is closer to CORD-2 value. The radial and axial powers are compared with other published results carried out using SAS2H/KENO-V code. Moreover, the WIMS-D5 code is used for studying the effect of enriched boron in form of ZrB2 on the effective multiplication factor (K-eff) of the fuel pin. In this part of calculation, K-eff is calculated at different concentrations of Boron-10 in mg/cm at different stages of burnup of unit cell. The results of this part are compared with published results performed by HELIOS code. Copyright © 2016 Elsevier Ltd. All rights reserved.
Important Literature in Endocrinology: Citation Analysis and Historial Methodology.
ERIC Educational Resources Information Center
Hurt, C. D.
1982-01-01
Results of a study comparing two approaches to the identification of important literature in endocrinology reveals that association between ranking of cited items using the two methods is not statistically significant and use of citation or historical analysis alone will not result in same set of literature. Forty-two sources are appended. (EJS)
ERIC Educational Resources Information Center
Martens, Brian K.; Gertz, Lynne E.; Werder, Candace Susan de Lacy; Rymanowski, Jennifer L.
2010-01-01
We compared the results of a contingency space analysis (CSA) of behavior-consequence recordings to the results of functional analysis (FA) test conditions involving antecedent stimuli and verbal statements that both differed from and mimicked those in the natural environment. Three preschool children with autism spectrum disorder participated.…
Amiryousefi, Mohammad Reza; Mohebbi, Mohebbat; Khodaiyan, Faramarz
2014-01-01
The objectives of this study were to use image analysis and artificial neural network (ANN) to predict mass transfer kinetics as well as color changes and shrinkage of deep-fat fried ostrich meat cubes. Two generalized feedforward networks were separately developed by using the operation conditions as inputs. Results based on the highest numerical quantities of the correlation coefficients between the experimental versus predicted values, showed proper fitting. Sensitivity analysis results of selected ANNs showed that among the input variables, frying temperature was the most sensitive to moisture content (MC) and fat content (FC) compared to other variables. Sensitivity analysis results of selected ANNs showed that MC and FC were the most sensitive to frying temperature compared to other input variables. Similarly, for the second ANN architecture, microwave power density was the most impressive variable having the maximum influence on both shrinkage percentage and color changes. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Oh, Won Jin; Jang, Jong Shik; Lee, Youn Seoung; Kim, Ansoon; Kim, Kyung Joong
2018-02-01
Quantitative analysis methods of multi-element alloy films were compared. The atomic fractions of Si1-xGex alloy films were measured by depth profiling analysis with secondary ion mass spectrometry (SIMS) and X-ray Photoelectron Spectroscopy (XPS). Intensity-to-composition conversion factor (ICF) was used as a mean to convert the intensities to compositions instead of the relative sensitivity factors. The ICFs were determined from a reference Si1-xGex alloy film by the conventional method, average intensity (AI) method and total number counting (TNC) method. In the case of SIMS, although the atomic fractions measured by oxygen ion beams were not quantitative due to severe matrix effect, the results by cesium ion beam were very quantitative. The quantitative analysis results by SIMS using MCs2+ ions are comparable to the results by XPS. In the case of XPS, the measurement uncertainty was highly improved by the AI method and TNC method.
Memory and Obstructive Sleep Apnea: A Meta-Analysis
Wallace, Anna; Bucks, Romola S.
2013-01-01
Study Objectives: To examine episodic memory performance in individuals with obstructive sleep apnea (OSA). Design Meta-analysis was used to synthesize results from individual studies examining the impact of OSA on episodic memory performance. The performance of individuals with OSA was compared to healthy controls or normative data. Participants Forty-two studies were included, comprising 2,294 adults with untreated OSA and 1,364 healthy controls. Studies that recorded information about participants at baseline prior to treatment interventions were included in the analysis. Measurements Participants were assessed with tasks that included a measure of episodic memory: immediate recall, delayed recall, learning, and/or recognition memory. Results: The results of the meta-analyses provide evidence that individuals with OSA are significantly impaired when compared to healthy controls on verbal episodic memory (immediate recall, delayed recall, learning, and recognition) and visuo-spatial episodic memory (immediate and delayed recall), but not visual immediate recall or visuo-spatial learning. When patients were compared to norms, negative effects of OSA were found only in verbal immediate and delayed recall. Conclusions: This meta-analysis contributes to understanding of the nature of episodic memory deficits in individuals with OSA. Impairments to episodic memory are likely to affect the daily functioning of individuals with OSA. Citation Wallace A; Bucks RS. Memory and obstructive sleep apnea: a meta-analysis. SLEEP 2013;36(2):203-220. PMID:23372268
Three-dimensional murine airway segmentation in micro-CT images
NASA Astrophysics Data System (ADS)
Shi, Lijun; Thiesse, Jacqueline; McLennan, Geoffrey; Hoffman, Eric A.; Reinhardt, Joseph M.
2007-03-01
Thoracic imaging for small animals has emerged as an important tool for monitoring pulmonary disease progression and therapy response in genetically engineered animals. Micro-CT is becoming the standard thoracic imaging modality in small animal imaging because it can produce high-resolution images of the lung parenchyma, vasculature, and airways. Segmentation, measurement, and visualization of the airway tree is an important step in pulmonary image analysis. However, manual analysis of the airway tree in micro-CT images can be extremely time-consuming since a typical dataset is usually on the order of several gigabytes in size. Automated and semi-automated tools for micro-CT airway analysis are desirable. In this paper, we propose an automatic airway segmentation method for in vivo micro-CT images of the murine lung and validate our method by comparing the automatic results to manual tracing. Our method is based primarily on grayscale morphology. The results show good visual matches between manually segmented and automatically segmented trees. The average true positive volume fraction compared to manual analysis is 91.61%. The overall runtime for the automatic method is on the order of 30 minutes per volume compared to several hours to a few days for manual analysis.
Hauge, Erik R.; Berle, Jan Øystein; Oedegaard, Ketil J.; Holsten, Fred; Fasmer, Ole Bernt
2011-01-01
The purpose of this study has been to describe motor activity data obtained by using wrist-worn actigraphs in patients with schizophrenia and major depression by the use of linear and non-linear methods of analysis. Different time frames were investigated, i.e., activity counts measured every minute for up to five hours and activity counts made hourly for up to two weeks. The results show that motor activity was lower in the schizophrenic patients and in patients with major depression, compared to controls. Using one minute intervals the depressed patients had a higher standard deviation (SD) compared to both the schizophrenic patients and the controls. The ratio between the root mean square successive differences (RMSSD) and SD was higher in the schizophrenic patients compared to controls. The Fourier analysis of the activity counts measured every minute showed that the relation between variance in the low and the high frequency range was lower in the schizophrenic patients compared to the controls. The sample entropy was higher in the schizophrenic patients compared to controls in the time series from the activity counts made every minute. The main conclusions of the study are that schizophrenic and depressive patients have distinctly different profiles of motor activity and that the results differ according to period length analysed. PMID:21297977
NASA Astrophysics Data System (ADS)
Czaja, Daniel; Chmielnak, Tadeusz; Lepszy, Sebastian
2014-12-01
A thermodynamic and economic analysis of a GT10 gas turbine integrated with the air bottoming cycle is presented. The results are compared to commercially available combined cycle power plants based on the same gas turbine. The systems under analysis have a better chance of competing with steam bottoming cycle configurations in a small range of the power output capacity. The aim of the calculations is to determine the final cost of electricity generated by the gas turbine air bottoming cycle based on a 25 MW GT10 gas turbine with the exhaust gas mass flow rate of about 80 kg/s. The article shows the results of thermodynamic optimization of the selection of the technological structure of gas turbine air bottoming cycle and of a comparative economic analysis. Quantities are determined that have a decisive impact on the considered units profitability and competitiveness compared to the popular technology based on the steam bottoming cycle. The ultimate quantity that can be compared in the calculations is the cost of 1 MWh of electricity. It should be noted that the systems analyzed herein are power plants where electricity is the only generated product. The performed calculations do not take account of any other (potential) revenues from the sale of energy origin certificates. Keywords: Gas turbine air bottoming cycle, Air bottoming cycle, Gas turbine, GT10
Doborjeh, Maryam Gholami; Wang, Grace Y; Kasabov, Nikola K; Kydd, Robert; Russell, Bruce
2016-09-01
This paper introduces a method utilizing spiking neural networks (SNN) for learning, classification, and comparative analysis of brain data. As a case study, the method was applied to electroencephalography (EEG) data collected during a GO/NOGO cognitive task performed by untreated opiate addicts, those undergoing methadone maintenance treatment (MMT) for opiate dependence and a healthy control group. the method is based on an SNN architecture called NeuCube, trained on spatiotemporal EEG data. NeuCube was used to classify EEG data across subject groups and across GO versus NOGO trials, but also facilitated a deeper comparative analysis of the dynamic brain processes. This analysis results in a better understanding of human brain functioning across subject groups when performing a cognitive task. In terms of the EEG data classification, a NeuCube model obtained better results (the maximum obtained accuracy: 90.91%) when compared with traditional statistical and artificial intelligence methods (the maximum obtained accuracy: 50.55%). more importantly, new information about the effects of MMT on cognitive brain functions is revealed through the analysis of the SNN model connectivity and its dynamics. this paper presented a new method for EEG data modeling and revealed new knowledge on brain functions associated with mental activity which is different from the brain activity observed in a resting state of the same subjects.
Modal analysis and acoustic transmission through offset-core honeycomb sandwich panels
NASA Astrophysics Data System (ADS)
Mathias, Adam Dustin
The work presented in this thesis is motivated by an earlier research that showed that double, offset-core honeycomb sandwich panels increased thermal resistance and, hence, decreased heat transfer through the panels. This result lead to the hypothesis that these panels could be used for acoustic insulation. Using commercial finite element modeling software, COMSOL Multiphysics, the acoustical properties, specifically the transmission loss across a variety of offset-core honeycomb sandwich panels, is studied for the case of a plane acoustic wave impacting the panel at normal incidence. The transmission loss results are compared with those of single-core honeycomb panels with the same cell sizes. The fundamental frequencies of the panels are also computed in an attempt to better understand the vibrational modes of these particular sandwich-structured panels. To ensure that the finite element analysis software is adequate for the task at hand, two relevant benchmark problems are solved and compared with theory. Results from these benchmark results compared well to those obtained from theory. Transmission loss results from the offset-core honeycomb sandwich panels show increased transmission loss, especially for large cell honeycombs when compared to single-core honeycomb panels.
Chen, Hongming; Carlsson, Lars; Eriksson, Mats; Varkonyi, Peter; Norinder, Ulf; Nilsson, Ingemar
2013-06-24
A novel methodology was developed to build Free-Wilson like local QSAR models by combining R-group signatures and the SVM algorithm. Unlike Free-Wilson analysis this method is able to make predictions for compounds with R-groups not present in a training set. Eleven public data sets were chosen as test cases for comparing the performance of our new method with several other traditional modeling strategies, including Free-Wilson analysis. Our results show that the R-group signature SVM models achieve better prediction accuracy compared with Free-Wilson analysis in general. Moreover, the predictions of R-group signature models are also comparable to the models using ECFP6 fingerprints and signatures for the whole compound. Most importantly, R-group contributions to the SVM model can be obtained by calculating the gradient for R-group signatures. For most of the studied data sets, a significant correlation with that of a corresponding Free-Wilson analysis is shown. These results suggest that the R-group contribution can be used to interpret bioactivity data and highlight that the R-group signature based SVM modeling method is as interpretable as Free-Wilson analysis. Hence the signature SVM model can be a useful modeling tool for any drug discovery project.
arrayCGHbase: an analysis platform for comparative genomic hybridization microarrays
Menten, Björn; Pattyn, Filip; De Preter, Katleen; Robbrecht, Piet; Michels, Evi; Buysse, Karen; Mortier, Geert; De Paepe, Anne; van Vooren, Steven; Vermeesch, Joris; Moreau, Yves; De Moor, Bart; Vermeulen, Stefan; Speleman, Frank; Vandesompele, Jo
2005-01-01
Background The availability of the human genome sequence as well as the large number of physically accessible oligonucleotides, cDNA, and BAC clones across the entire genome has triggered and accelerated the use of several platforms for analysis of DNA copy number changes, amongst others microarray comparative genomic hybridization (arrayCGH). One of the challenges inherent to this new technology is the management and analysis of large numbers of data points generated in each individual experiment. Results We have developed arrayCGHbase, a comprehensive analysis platform for arrayCGH experiments consisting of a MIAME (Minimal Information About a Microarray Experiment) supportive database using MySQL underlying a data mining web tool, to store, analyze, interpret, compare, and visualize arrayCGH results in a uniform and user-friendly format. Following its flexible design, arrayCGHbase is compatible with all existing and forthcoming arrayCGH platforms. Data can be exported in a multitude of formats, including BED files to map copy number information on the genome using the Ensembl or UCSC genome browser. Conclusion ArrayCGHbase is a web based and platform independent arrayCGH data analysis tool, that allows users to access the analysis suite through the internet or a local intranet after installation on a private server. ArrayCGHbase is available at . PMID:15910681
NASA Astrophysics Data System (ADS)
Potter, Jennifer L.
2011-12-01
Noise and vibration has long been sought to be reduced in major industries: automotive, aerospace and marine to name a few. Products must be tested and pass certain levels of federally regulated standards before entering the market. Vibration measurements are commonly acquired using accelerometers; however limitations of this method create a need for alternative solutions. Two methods for non-contact vibration measurements are compared: Laser Vibrometry, which directly measures the surface velocity of the aluminum plate, and Nearfield Acoustic Holography (NAH), which measures sound pressure in the nearfield, and using Green's Functions, reconstructs the surface velocity at the plate. The surface velocity from each method is then used in modal analysis to determine the comparability of frequency, damping and mode shapes. Frequency and mode shapes are also compared to an FEA model. Laser Vibrometry is a proven, direct method for determining surface velocity and subsequently calculating modal analysis results. NAH is an effective method in locating noise sources, especially those that are not well separated spatially. Little work has been done in incorporating NAH into modal analysis.
A multifaceted independent performance analysis of facial subspace recognition algorithms.
Bajwa, Usama Ijaz; Taj, Imtiaz Ahmad; Anwar, Muhammad Waqas; Wang, Xuan
2013-01-01
Face recognition has emerged as the fastest growing biometric technology and has expanded a lot in the last few years. Many new algorithms and commercial systems have been proposed and developed. Most of them use Principal Component Analysis (PCA) as a base for their techniques. Different and even conflicting results have been reported by researchers comparing these algorithms. The purpose of this study is to have an independent comparative analysis considering both performance and computational complexity of six appearance based face recognition algorithms namely PCA, 2DPCA, A2DPCA, (2D)(2)PCA, LPP and 2DLPP under equal working conditions. This study was motivated due to the lack of unbiased comprehensive comparative analysis of some recent subspace methods with diverse distance metric combinations. For comparison with other studies, FERET, ORL and YALE databases have been used with evaluation criteria as of FERET evaluations which closely simulate real life scenarios. A comparison of results with previous studies is performed and anomalies are reported. An important contribution of this study is that it presents the suitable performance conditions for each of the algorithms under consideration.
Li, Mingchao; Wang, Zhengyun
2016-01-01
Objective To perform a meta-analysis of data from available published studies comparing laparoendoscopic single-site surgery varicocelectomy (LESSV) with conventional transperitoneal laparoscopic varicocele ligation. Methods A comprehensive data search was performed in PubMed and Embase to identify randomized controlled trials and comparative studies that compared the two surgical approaches for the treatment of varicoceles. Results Six studies were included in the meta-analysis. LESSV required a significantly longer operative time than conventional laparoscopic varicocelectomy but was associated with significantly less postoperative pain at 6 h and 24 h, a shorter recovery time and greater patient satisfaction with the cosmetic outcome. There was no difference between the two surgical approaches in terms of postoperative semen quality or the incidence of complications. Conclusion These data suggest that LESSV offers a well tolerated and efficient alternative to conventional laparoscopic varicocelectomy, with less pain, a shorter recovery time and better cosmetic satisfaction. Further well-designed studies are required to confirm these findings and update the results of this meta-analysis. PMID:27688686
Brigo, Francesco; Bragazzi, Nicola; Nardone, Raffaele; Trinka, Eugen
2016-11-01
The aim of this study was to conduct a meta-analysis of published studies to directly compare intravenous (IV) levetiracetam (LEV) with IV phenytoin (PHT) or IV valproate (VPA) as second-line treatment of status epilepticus (SE), to indirectly compare intravenous IV LEV with IV VPA using common reference-based indirect comparison meta-analysis, and to verify whether results of indirect comparisons are consistent with results of head-to-head randomized controlled trials (RCTs) directly comparing IV LEV with IV VPA. Random-effects Mantel-Haenszel meta-analyses to obtain odds ratios (ORs) for efficacy and safety of LEV versus VPA and LEV or VPA versus PHT were used. Adjusted indirect comparisons between LEV and VPA were used. Two RCTs comparing LEV with PHT (144 episodes of SE) and 3 RCTs comparing VPA with PHT (227 episodes of SE) were included. Direct comparisons showed no difference in clinical seizure cessation, neither between VPA and PHT (OR: 1.07; 95% CI: 0.57 to 2.03) nor between LEV and PHT (OR: 1.18; 95% CI: 0.50 to 2.79). Indirect comparisons showed no difference between LEV and VPA for clinical seizure cessation (OR: 1.16; 95% CI: 0.45 to 2.97). Results of indirect comparisons are consistent with results of a recent RCT directly comparing LEV with VPA. The absence of a statistically significant difference in direct and indirect comparisons is due to the lack of sufficient statistical power to detect a difference. Conducting a RCT that has not enough people to detect a clinically important difference or to estimate an effect with sufficient precision can be regarded a waste of time and resources and may raise several ethical concerns, especially in RCT on SE. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Ault, Hugh J.; Glendon, Mary Ann
1976-01-01
Discusses the rationale for teaching comparative law and describes techniques and results of experiments with two kinds of courses at Boston College Law School: (1) Comparative Legal Analysis, a perspective course, and (2) integration of comparative law as another dimension into courses in a particular subject matter area. (JT)
TSP Symposium 2013 Proceedings
2014-01-01
test and Post - test Results of the Experimental Group Our results show that the experimental group improved on the post - test compared...4.3.4 Design of the Learning Strategy 27 4.4 Results 28 4.4.1 Post - test 28 4.4.2 Analysis of the Results 28 4.4.3 Analysis of the Results from the...Estimation Accuracy) 17 Figure 5: Methodology for the Research 24 Figure 6: Question 1, Time Control for Post - test 28 Figure 7:
NASA Technical Reports Server (NTRS)
Balla, R. Jeffrey; Miller, Corey A.
2008-01-01
This study seeks a numerical algorithm which optimizes frequency precision for the damped sinusoids generated by the nonresonant LITA technique. It compares computed frequencies, frequency errors, and fit errors obtained using five primary signal analysis methods. Using variations on different algorithms within each primary method, results from 73 fits are presented. Best results are obtained using an AutoRegressive method. Compared to previous results using Prony s method, single shot waveform frequencies are reduced approx.0.4% and frequency errors are reduced by a factor of approx.20 at 303K to approx. 0.1%. We explore the advantages of high waveform sample rates and potential for measurements in low density gases.
Stidham, R W; Lee, T C H; Higgins, P D R; Deshpande, A R; Sussman, D A; Singal, A G; Elmunzer, B J; Saini, S D; Vijan, S; Waljee, A K
2014-04-01
Antibodies against tumour necrosis factor-alpha (anti-TNF) are effective therapies in the treatment of ulcerative colitis (UC), but their comparative efficacy is unknown. To perform a network meta-analysis comparing the efficacy of anti-TNF agents in UC. After screening 506 studies, reviewers extracted information on seven studies. Traditional meta-analysis (TMA) was used to compare each anti-TNF agent to placebo. Bayesian network meta-analysis (NMA) was performed to compare the effects of anti-TNF agents to placebo. In addition, sample sizes for comparative efficacy trials were calculated. Compared to placebo, TMA revealed that anti-TNF agents result in a higher likelihood of induction of remission and response (RR: 2.45, 95% CI: 1.72-3.47 and RR: 1.65, 95% CI: 1.37-1.99 respectively) as well as maintenance of remission and response (RR: 2.00, 95% CI: 1.52-2.62 and RR: 1.76, 95% CI: 1.46-2.14 respectively). Individually, infliximab, adalimumab and goliumumab resulted in a higher likelihood of induction and maintenance for both remission and response. NMA found nonsignificant trends in comparisons of the individual agents. The required sample sizes for direct head-to-head trials between infliximab and adalimumab for induction and maintenance are 174 and 204 subjects respectively. This study demonstrates that, compared to placebo, infliximab, adalimumab and golimumab are all effective for the induction and maintenance of remission in ulcerative colitis. However, network meta-analysis demonstrates that no single agent is clinically superior to the others and therefore, other factors such as cost, safety, route of administration and patient preference should dictate our choice of anti-TNF agents. A randomised comparative efficacy trial between infliximab and adalimumab in UC is of practical size and should be performed. © 2014 John Wiley & Sons Ltd.
Skills for the 21st Century Supervisor: What Factory Personnel Think.
ERIC Educational Resources Information Center
Hotek, Douglas R.
2002-01-01
Discusses supervisory skills that factory personnel believe are important for leading and improving employee performance in complex manufacturing environments. Highlights include a historical perspective; manufacturing technologies; results of Pareto analysis, comparative analysis, and analysis of variance; and a Taxonomy of Supervisory Skills.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Jeremy P.; Murphy, James D.; Hanlon, Alexandra L.
2014-03-15
Purpose: Concerns have been raised about the potential for worse treatment outcomes because of dosimetric inaccuracies related to tumor motion and increased toxicity caused by the spread of low-dose radiation to normal tissues in patients with locally advanced non-small cell lung cancer (NSCLC) treated with intensity modulated radiation therapy (IMRT). We therefore performed a population-based comparative effectiveness analysis of IMRT, conventional 3-dimensional conformal radiation therapy (3D-CRT), and 2-dimensional radiation therapy (2D-RT) in stage III NSCLC. Methods and Materials: We used the Surveillance, Epidemiology, and End Results (SEER)-Medicare database to identify a cohort of patients diagnosed with stage III NSCLC frommore » 2002 to 2009 treated with IMRT, 3D-CRT, or 2D-RT. Using Cox regression and propensity score matching, we compared survival and toxicities of these treatments. Results: The proportion of patients treated with IMRT increased from 2% in 2002 to 25% in 2009, and the use of 2D-RT decreased from 32% to 3%. In univariate analysis, IMRT was associated with improved overall survival (OS) (hazard ratio [HR] 0.90, P=.02) and cancer-specific survival (CSS) (HR 0.89, P=.02). After controlling for confounders, IMRT was associated with similar OS (HR 0.94, P=.23) and CSS (HR 0.94, P=.28) compared with 3D-CRT. Both techniques had superior OS compared with 2D-RT. IMRT was associated with similar toxicity risks on multivariate analysis compared with 3D-CRT. Propensity score matched model results were similar to those from adjusted models. Conclusions: In this population-based analysis, IMRT for stage III NSCLC was associated with similar OS and CSS and maintained similar toxicity risks compared with 3D-CRT.« less
Strietzel, Frank Peter; Neumann, Konrad; Hertel, Moritz
2015-01-01
Objective To address the focused question, is there an impact of platform switching (PS) on marginal bone level (MBL) changes around endosseous implants compared to implants with platform matching (PM) implant-abutment configurations? Material and methods A systematic literature search was conducted using electronic databases PubMed, Web of Science, Journals@Ovid Full Text and Embase, manual search for human randomized clinical trials (RCTs) and prospective clinical controlled cohort studies (PCCS) reporting on MBL changes at implants with PS-, compared with PM-implant-abutment connections, published between 2005 and June 2013. Results Twenty-two publications were eligible for the systematic review. The qualitative analysis of 15 RCTs and seven PCCS revealed more studies (13 RCTs and three PCCS) showing a significantly less mean marginal bone loss around implants with PS- compared to PM-implant-abutment connections, indicating a clear tendency favoring the PS technique. A meta-analysis including 13 RCTs revealed a significantly less mean MBL change (0.49 mm [CI95% 0.38; 0.60]) at PS implants, compared with PM implants (1.01 mm [CI95% 0.62; 1.40] (P < 0.0001). Conclusions The meta-analysis revealed a significantly less mean MBL change at implants with a PS compared to PM-implant-abutment configuration. Studies included herein showed an unclear as well as high risk of bias mostly, and relatively short follow-up periods. The qualitative analysis revealed a tendency favoring the PS technique to prevent or minimize peri-implant marginal bone loss compared with PM technique. Due to heterogeneity of the included studies, their results require cautious interpretation. PMID:24438506
Lee, Kyeong-Tae; Mun, Goo-Hyun
2017-07-01
The current diversity of the available acellular dermal matrix (ADM) materials for implant-based breast reconstruction raises the issue of whether there are any differences in postoperative outcomes according to the kind of ADM used. The present meta-analysis aimed to investigate whether choice of ADM products can affect outcomes. Studies that used multiple kinds of ADM products for implant-based breast reconstruction and compared outcomes between them were searched. Outcomes of interest were rates of postoperative complications: infection, seroma, mastectomy flap necrosis, reconstruction failure, and overall complications. A total of 17 studies met the selection criteria. There was only 1 randomized controlled trial, and the other 16 studies had retrospective designs. Comparison of FlexHD, DermaMatrix, and ready-to-use AlloDerm with freeze-dried AlloDerm was conducted in multiple studies and could be meta-analyzed, in which 12 studies participated. In the meta-analysis comparing FlexHD and freeze-dried AlloDerm, using the results of 6 studies, both products showed similar pooled risks for all kinds of complications. When comparing DermaMatrix and freeze-dried AlloDerm with the results from 4 studies, there were also no differences between the pooled risks of complications of the two. Similarly, the meta-analysis of 4 studies comparing ready-to-use and freeze-dried AlloDerm demonstrated that the pooled risks for the complications did not differ. This meta-analysis demonstrates that the 3 recently invented, human cadaveric skin-based products of FlexHD, DermaMatrix, and ready-to-use AlloDerm have similar risks of complications compared with those of freeze-dried AlloDerm, which has been used for longer. However, as most studies had low levels of evidence, further investigations are needed.
Independent Orbiter Assessment (IOA): Assessment of the Orbiter Experiment (OEX) subsystem
NASA Technical Reports Server (NTRS)
Compton, J. M.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Orbiter Experiments (OEX) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter OEX hardware are documented. The IOA product for the OEX analysis consisted of 82 failure mode worksheets that resulted in two potential critical items being identified.
Kotani, Kiyoshi; Takamasu, Kiyoshi; Tachibana, Makoto
2007-01-01
The objectives of this paper were to present a method to extract the amplitude of RSA in the respiratory-phase domain, to compare that with subjective or objective indices of the MWL (mental workload), and to compare that with a conventional frequency analysis in terms of its accuracy during a mental arithmetic task. HRV (heart rate variability), ILV (instantaneous lung volume), and motion of the throat were measured under a mental arithmetic experiment and subjective and objective indices were also obtained. The amplitude of RSA was extracted in the respiratory-phase domain, and its correlation with the load level was compared with the results of the frequency domain analysis, which is the standard analysis of the HRV. The subjective and objective indices decreased as the load level increased, showing that the experimental protocol was appropriate. Then, the amplitude of RSA in the respiratory-phase domain also decreased with the increase in the load level. The results of the correlation analysis showed that the respiratory-phase domain analysis has higher negative correlations, -0.84 and -0.82, with the load level as determined by simple correlation and rank correlation, respectively, than does frequency analysis, for which the correlations were found to be -0.54 and -0.63, respectively. In addition, it was demonstrated that the proposed method could be applied to the short-term extraction of RSA amplitude. We proposed a simple and effective method to extract the amplitude of the respiratory sinus arrhythmia (RSA) in the respiratory-phase domain and the results show that this method can estimate cardiac vagal activity more accurately than frequency analysis.
Kawalec, Paweł; Malinowski, Krzysztof Piotr
2015-04-01
The aim of this systematic review was to collect all current data on indirect costs related to inflammatory bowel disease as well as assessing homogeneity and comparability, and conducting a meta-analysis. Costs were collected using databases from Medline, Embase and Centre for Reviews and Dissemination databases, then average annual cost per patient was calculated and expressed in 2013-rate USD using the consumer price index and purchasing power parity (scenario 1) and then adjusted to specific gross domestic product (scenario 2) to make them comparable. The studies were then included in quantitative synthesis using the meta-analysis and bootstrap methods. This systematic review was carried out and reported in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. From 18 publications, overall annual indirect costs per patient as a result of the quantitative synthesis among all studies eligible for meta-analysis ranged from US$2425.01-US$9622.15 depending on the scenario and model used for analysis. The cost of presenteeism was assessed in only two studies. Considering heterogeneity among all identified studies random-effect model presented the most accurate results of meta-analysis equal to US$7189.27 and US$9622.15 per patient per year for scenario 1 and scenario 2, respectively. This systematic review revealed the existence of a relatively small number of studies that reported on the great economic burden of the disease upon society. A great variety of methodologies and cost components resulted in a very large discrepancy in indirect costs and made meta-analysis difficult to perform, so two scenarios were considered and meta-analysis conducted in subgroups to make data more comparable.
Loop Evolution Observed with AIA and Hi-C
NASA Technical Reports Server (NTRS)
Mulu-Moore, Fana; Winebarger, Amy R.; Cirtain, Jonathan W.; Kobayashi, Ken; Korreck, Kelly E.; Golub, Leon; Kuzin, Sergei; Walsh, Robert William; DeForest, Craig E.; De Pontieu, Bart;
2012-01-01
In the past decade, the evolution of EUV loops has been used to infer the loop substructure. With the recent launch of High Resolution Coronal Imager (Hi-C), this inference can be validated. In this presentation we discuss the first results of loop analysis comparing AIA and Hi-C data. In the past decade, the evolution of EUV loops has been used to infer the loop substructure. With the recent launch of High Resolution Coronal Imager (Hi-C), this inference can be validated. In this presentation we discuss the first results of loop analysis comparing AIA and Hi-C data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartman, J.S.; Gordon, R.L.; Lessor, D.L.
1981-08-01
Alternate measurement and data analysis procedures are discussed and compared for the application of reflective Nomarski differential interference contrast microscopy for the determination of surface slopes. The discussion includes the interpretation of a previously reported iterative procedure using the results of a detailed optical model and the presentation of a new procedure based on measured image intensity extrema. Surface slope determinations from these procedures are presented and compared with results from a previously reported curve fit analysis of image intensity data. The accuracy and advantages of the different procedures are discussed.
An empirical comparison of a dynamic software testability metric to static cyclomatic complexity
NASA Technical Reports Server (NTRS)
Voas, Jeffrey M.; Miller, Keith W.; Payne, Jeffrey E.
1993-01-01
This paper compares the dynamic testability prediction technique termed 'sensitivity analysis' to the static testability technique termed cyclomatic complexity. The application that we chose in this empirical study is a CASE generated version of a B-737 autoland system. For the B-737 system we analyzed, we isolated those functions that we predict are more prone to hide errors during system/reliability testing. We also analyzed the code with several other well-known static metrics. This paper compares and contrasts the results of sensitivity analysis to the results of the static metrics.
Dave, Mihika B; Dherai, Alpa J; Udani, Vrajesh P; Hegde, Anaita U; Desai, Neelu A; Ashavaid, Tester F
2018-01-01
Transferrin, a major glycoprotein has different isoforms depending on the number of sialic acid residues present on its oligosaccharide chain. Genetic variants of transferrin as well as the primary (CDG) & secondary glycosylation defects lead to an altered transferrin pattern. Isoform analysis methods are based on charge/mass variations. We aimed to compare the performance of commercially available capillary electrophoresis CDT kit for diagnosing congenital disorders of glycosylation with our in-house optimized HPLC method for transferrin isoform analysis. The isoform pattern of 30 healthy controls & 50 CDG-suspected patients was determined by CE using a Carbohydrate-Deficient Transferrin kit. The results were compared with in-house HPLC-based assay for transferrin isoforms. Transferrin isoform pattern for healthy individuals showed a predominant tetrasialo transferrin fraction followed by pentasialo, trisialo, and disialotransferrin. Two of 50 CDG-suspected patients showed the presence of asialylated isoforms. The results were comparable with isoform pattern obtained by HPLC. The commercial controls showed a <20% CV for each isoform. Bland Altman plot showed the difference plot to be within +1.96 with no systemic bias in the test results by HPLC & CE. The CE method is rapid, reproducible and comparable with HPLC and can be used for screening Glycosylation defects. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Mariappan, G.; Sundaraganesan, N.
2015-04-01
A comprehensive screening of the density functional theoretical approach to structural analysis is presented in this section. DFT calculations using B3LYP/6-311++G(d,p) level of theory were found to yield results that are very comparable to experimental IR and Raman spectra. Computed geometrical parameters and harmonic vibrational wavenumbers of the fundamentals were found in satisfactory agreement with the experimental data and also its parent structure. The vibrational assignments of the normal modes were performed on the basis of the potential energy distribution (PED) calculations. It can be proven from the comparative results of mitotane and its parent structure Dichlorodiphenyldichloroethane (DDD), the intramolecular nonbonding interaction between (C1sbnd H19⋯Cl18) in the ortho position which is calculated 2.583 Å and the position of the substitution takeover the vibrational wavenumber to redshift of 47 cm-1. In addition, natural bond orbital (NBO) analysis has been performed for analyzing charge delocalization throughout the molecule. Stability of the molecule arising from hyperconjugative interactions leading to its bioactivity and charge delocalization has been analyzed. 13C and 1H nuclear magnetic resonance chemical shifts of the molecule have been calculated using the gauge independent atomic orbital (GIAO) method and compared with published results.
Cehreli, S Burcak; Polat-Ozsoy, Omur; Sar, Cagla; Cubukcu, H Evren; Cehreli, Zafer C
2012-04-01
The amount of the residual adhesive after bracket debonding is frequently assessed in a qualitative manner, utilizing the adhesive remnant index (ARI). This study aimed to investigate whether quantitative assessment of the adhesive remnant yields more precise results compared to qualitative methods utilizing the 4- and 5-point ARI scales. Twenty debonded brackets were selected. Evaluation and scoring of the adhesive remnant on bracket bases were made consecutively using: 1. qualitative assessment (visual scoring) and 2. quantitative measurement (image analysis) on digital photographs. Image analysis was made on scanning electron micrographs (SEM) and high-precision elemental maps of the adhesive remnant as determined by energy dispersed X-ray spectrometry. Evaluations were made in accordance with the original 4-point and the modified 5-point ARI scales. Intra-class correlation coefficients (ICCs) were calculated, and the data were evaluated using Friedman test followed by Wilcoxon signed ranks test with Bonferroni correction. ICC statistics indicated high levels of agreement for qualitative visual scoring among examiners. The 4-point ARI scale was compliant with the SEM assessments but indicated significantly less adhesive remnant compared to the results of quantitative elemental mapping. When the 5-point scale was used, both quantitative techniques yielded similar results with those obtained qualitatively. These results indicate that qualitative visual scoring using the ARI is capable of generating similar results with those assessed by quantitative image analysis techniques. In particular, visual scoring with the 5-point ARI scale can yield similar results with both the SEM analysis and elemental mapping.
A Comparative Analysis of Bicycle Lanes Versus Wide Curb Lanes
DOT National Transportation Integrated Search
2013-11-01
Analysis Modeling and Simulation (AMS) Testbeds can make significant contributions in identifying the benefits of more effective, more active systems management, resulting from integrating transformative applications enabled by new data from wireless...
Letter Report: Stable Hydrogen and Oxygen Isotope Analysis of B-Complex Groundwater Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Brady D.; Moran, James J.; Nims, Megan K.
Report summarizing stable oxygen and hydrogen isotope analysis of two groundwater samples from the B-Complex. Results from analyses were compared to perched water and pore water analyses performed previously.
A value-based medicine cost-utility analysis of idiopathic epiretinal membrane surgery.
Gupta, Omesh P; Brown, Gary C; Brown, Melissa M
2008-05-01
To perform a reference case, cost-utility analysis of epiretinal membrane (ERM) surgery using current literature on outcomes and complications. Computer-based, value-based medicine analysis. Decision analyses were performed under two scenarios: ERM surgery in better-seeing eye and ERM surgery in worse-seeing eye. The models applied long-term published data primarily from the Blue Mountains Eye Study and the Beaver Dam Eye Study. Visual acuity and major complications were derived from 25-gauge pars plana vitrectomy studies. Patient-based, time trade-off utility values, Markov modeling, sensitivity analysis, and net present value adjustments were used in the design and calculation of results. Main outcome measures included the number of discounted quality-adjusted-life-years (QALYs) gained and dollars spent per QALY gained. ERM surgery in the better-seeing eye compared with observation resulted in a mean gain of 0.755 discounted QALYs (3% annual rate) per patient treated. This model resulted in $4,680 per QALY for this procedure. When sensitivity analysis was performed, utility values varied from $6,245 to $3,746/QALY gained, medical costs varied from $3,510 to $5,850/QALY gained, and ERM recurrence rate increased to $5,524/QALY. ERM surgery in the worse-seeing eye compared with observation resulted in a mean gain of 0.27 discounted QALYs per patient treated. The $/QALY was $16,146 with a range of $20,183 to $12,110 based on sensitivity analyses. Utility values ranged from $21,520 to $12,916/QALY and ERM recurrence rate increased to $16,846/QALY based on sensitivity analysis. ERM surgery is a very cost-effective procedure when compared with other interventions across medical subspecialties.
NASA Astrophysics Data System (ADS)
Turba, Tomasz; Frącz, Paweł
2017-10-01
The paper presents results of a comparative analysis of parameters of two kinds of solid dielectrics used in air insulation systems to prevent occurring partial discharges. The research works regarded materials made of: cellulose pressboard and aramid paper. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage until breakdown occurred in the inhomogeneous environment that was simulated using needle-plate (made of copper) electrode system. The main contribution which resulted from studies is a statement that potential use of aramid paper as a dielectric can extend the life of a high voltage electric device as compared to standard cellulose pressboard usage due to higher electric resistances to breakdown or detection of corona voltage. Results shown that the aramid paper has greater electric resistance to breakdown in comparison to cellulose with no difference between both on detecting corona of partial discharge.
2017-05-10
repertoire-wide properties. Finally, through 75 the use of appropriate statistical analyses, the repertoire profiles can be quantitatively compared and 76...cell response to eVLP and 503 quantitatively compare GC B-cell repertoires from immunization conditions. We partitioned the 504 resulting clonotype... Quantitative analysis of repertoire-scale immunoglobulin properties in vaccine-induced B-cell responses Ilja V. Khavrutskii1, Sidhartha Chaudhury*1
Makeeva, I M; Moskalev, E E; Kuz'ko, E I
2010-01-01
A new method of color quality control based on spectrophotometry has been developed for dental restoration. A comparative analysis of quality of subjective color control by trained and non-trained observers has been made. Based on comparative analysis of the results of subjective color-control and spectrophotometry the maximum amount of allowed color difference has been set (dE=2.8).
A comparison of hand-wrist bone and cervical vertebral analyses in measuring skeletal maturation.
Gandini, Paola; Mancini, Marta; Andreani, Federico
2006-11-01
To compare skeletal maturation as measured by hand-wrist bone analysis and by cervical vertebral analysis. A radiographic hand-wrist bone analysis and cephalometric cervical vertebral analysis of 30 patients (14 males and 16 females; 7-18 years of age) were examined. The hand-wrist bone analysis was evaluated by the Bjork index, whereas the cervical vertebral analysis was assessed by the cervical vertebral maturation stage (CVMS) method. To define vertebral stages, the analysis consisted of both cephalometric (13 points) and morphologic evaluation of three cervical vertebrae (concavity of second, third, and fourth vertebrae and shape of third and fourth vertebrae). These measurements were then compared with the hand-wrist bone analysis, and the results were statistically analyzed by the Cohen kappa concordance index. The same procedure was repeated after 6 months and showed identical results. The Cohen kappa index obtained (mean +/- SD) was 0.783 +/- 0.098, which is in the significant range. The results show a concordance of 83.3%, considering that the estimated percentage for each case is 23.3%. The results also show a correlation of CVMS I with Bjork stages 1-3 (interval A), CVMS II with Bjork stage 4 (interval B), CVMS III with Bjork stage 5 (interval C), CVMS IV with Bjork stages 6 and 7 (interval D), and CVMS V with Bjork stages 8 and 9 (interval E). Vertebral analysis on a lateral cephalogram is as valid as the hand-wrist bone analysis with the advantage of reducing the radiation exposure of growing subjects.
Measuring What People Value: A Comparison of “Attitude” and “Preference” Surveys
Phillips, Kathryn A; Johnson, F Reed; Maddala, Tara
2002-01-01
Objective To compare and contrast methods and findings from two approaches to valuation used in the same survey: measurement of “attitudes” using simple rankings and ratings versus measurement of “preferences” using conjoint analysis. Conjoint analysis, a stated preference method, involves comparing scenarios composed of attribute descriptions by ranking, rating, or choosing scenarios. We explore possible explanations for our findings using focus groups conducted after the quantitative survey. Methods A self-administered survey, measuring attitudes and preferences for HIV tests, was conducted at HIV testing sites in San Francisco in 1999–2000 (n = 365, response rate=96 percent). Attitudes were measured and analyzed using standard approaches. Conjoint analysis scenarios were developed using a fractional factorial design and results analyzed using random effects probit models. We examined how the results using the two approaches were both similar and different. Results We found that “attitudes” and “preferences” were generally consistent, but there were some important differences. Although rankings based on the attitude and conjoint analysis surveys were similar, closer examination revealed important differences in how respondents valued price and attributes with “halo” effects, variation in how attribute levels were valued, and apparent differences in decision-making processes. Conclusions To our knowledge, this is the first study to compare attitude surveys and conjoint analysis surveys and to explore the meaning of the results using post-hoc focus groups. Although the overall findings for attitudes and preferences were similar, the two approaches resulted in some different conclusions. Health researchers should consider the advantages and limitations of both methods when determining how to measure what people value. PMID:12546291
A dynamic analysis of rotary combustion engine seals
NASA Technical Reports Server (NTRS)
Knoll, J.; Vilmann, C. R.; Schock, H. J.; Stumpf, R. P.
1984-01-01
Real time work cell pressures are incorporated into a dynamic analysis of the gas sealing grid in Rotary Combustion Engines. The analysis which utilizes only first principal concepts accounts for apex seal separation from the crochoidal bore, apex seal shifting between the sides of its restraining channel, and apex seal rotation within the restraining channel. The results predict that apex seals do separate from the trochoidal bore and shift between the sides of their channels. The results also show that these two motions are regularly initiated by a seal rotation. The predicted motion of the apex seals compares favorably with experimental results. Frictional losses associated with the sealing grid are also calculated and compare well with measurements obtained in a similar engine. A comparison of frictional losses when using steel and carbon apex seals has also been made as well as friction losses for single and dual side sealing.
An Evaluation of the Effects of Variable Sampling on Component, Image, and Factor Analysis.
ERIC Educational Resources Information Center
Velicer, Wayne F.; Fava, Joseph L.
1987-01-01
Principal component analysis, image component analysis, and maximum likelihood factor analysis were compared to assess the effects of variable sampling. Results with respect to degree of saturation and average number of variables per factor were clear and dramatic. Differential effects on boundary cases and nonconvergence problems were also found.…
Comparative Analysis of Languages for Machine Processing. Interim Report.
ERIC Educational Resources Information Center
Zierer, Ernesto; And Others
This report gives the results obtained in the semantic and syntactic analysis of the Japanese particles "de,""ni,""e," and "wo" in comparison to their equivalents in English, German, and Spanish. The study is based on the so-called "Correlational Analysis" as proposed by Ernst von Glaserfeld. The…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stallmann, F.W.
1984-08-01
A statistical analysis of Charpy test results of the two-year Pressure Vessel Simulation metallurgical irradiation experiment was performed. Determination of transition temperature and upper shelf energy derived from computer fits compare well with eyeball fits. Uncertainties for all results can be obtained with computer fits. The results were compared with predictions in Regulatory Guide 1.99 and other irradiation damage models.
Fluctuation dynamics of exchange rates on Polish financial market
NASA Astrophysics Data System (ADS)
Orłowski, A.; Struzik, Z. R.; Syczewska, E.; Załuska-Kotur, M. A.
2004-12-01
We show results of local fluctuation analysis, probability distributions, and fractional integration analysis for nominal exchange rates of the Polish zloty versus two foreign currencies (US dollar and German mark/euro). The results confirm the rapid change of the volatility pattern in August 1997. We compare the type of the fluctuation behavior before and after this date.
Ibarra, Alvin; Astbury, Nerys M.; Olli, Kaisa; Alhoniemi, Esa; Tiihonen, Kirsti
2016-01-01
Introduction: Subjective feelings of appetite are measured using visual analogue scales (VAS) in controlled trials. However, the methods used to analyze VAS during the Satiation (pre- to post-meal) and Satiety (post-meal to subsequent meal) periods vary broadly, making it difficult to compare results amongst independent studies testing the same product. This review proposes a methodology to analyze VAS during both the Satiation and Satiety periods, allowing us to compare results in a meta-analysis. Methods: A methodology to express VAS results as incremental areas under the curve (iAUC) for both the Satiation and Satiety periods is proposed using polydextrose as a case study. Further, a systematic review and meta-analysis on subjective feelings of appetite was conducted following the PRISMA methodology. Meta-analyses were expressed as Standardized Mean Difference (SMD). Results: Seven studies were included in the meta-analysis. There were important differences in the methods used to analyze appetite ratings amongst these studies. The separate subjective feelings of appetite reported were Hunger, Satisfaction, Fullness, Prospective Food Consumption, and the Desire to Eat. The method proposed here allowed the results of the different studies to be homogenized. The meta-analysis showed that Desire to Eat during the Satiation period favors polydextrose for the reduction of this subjective feeling of appetite (SMD = 0.24, I2 < 0.01, p = 0.018); this effect was also significant in the sub-analysis by sex for the male population (SMD = 0.35, I2 < 0.01, p = 0.015). There were no other significant results. Conclusion: It is possible to compare VAS results from separate studies. The assessment of iAUC for both the Satiation and Satiety periods generates results of homogeneous magnitudes. This case study demonstrates, for the first time, that polydextrose reduces the Desire to Eat during the Satiation period. This may explain, at least in part, the observed effects of polydextrose on the reduction of levels of energy intake at subsequent meals. PMID:26784221
Goeree, Ron; Goeree, Jeff
2016-01-01
Approximately 20-30% of Canadians suffer from chronic pain. Guidelines for the management of chronic pain support the use of controlled-release (CR) opioids to treat chronic pain. Although effective in managing chronic pain, oxycodone is associated with high rates of opioid-induced constipation (OIC). The cost-effectiveness of a combination of oxycodone for the management of pain and naloxone for the relief of OIC has not previously been evaluated for Canada. A decision analytic model was developed to estimate the cost-utility of combination oxycodone/naloxone compared to oxycodone alone in four populations. Drug costs for managing pain and healthcare costs related to managing OIC were included in the analysis and the primary measure of effectiveness was quality adjusted life years (QALYs) derived from OIC rates observed in clinical trials. The analysis was conducted from a healthcare system perspective, used a 1-year time horizon, and results were expressed in 2015 Canadian dollars. In all four patient populations, there was a trade-off between slightly higher total expected costs for Targin treated patients compared to oxycodone treated patients, but also improved clinical benefits in terms of reduced OIC, which resulted in higher QALYs for patients. Although analgesic costs were found to be slightly higher for Targin treated patients, Targin also resulted in cost offsets to the healthcare system in terms of less rescue laxative drug use and other resources required for the management of OIC. The resulting 1-year cost-utility of Targin compared to oxycodone ranged from $2178-$7732 per QALY gained in the base case analysis, and it was found that these cost-utility results remained robust and at low values throughout a series of one-way deterministic analyses of uncertainty. The clinical effectiveness of oxycodone/naloxone in managing pain and OIC compared to CR oxycodone alone resulted in low cost-utility estimates.
Independent Orbiter Assessment (IOA): Assessment of the extravehicular mobility unit, volume 1
NASA Technical Reports Server (NTRS)
Raffaelli, Gary G.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort performed an independent analysis of the Extravehicular Mobility Unit (EMU) hardware and system, generating draft failure modes criticalities and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to the most recent proposed Post 51-L NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison was provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EMU hardware.
Independent Orbiter Assessment (IOA): Assessment of the data processing system FMEA/CIL
NASA Technical Reports Server (NTRS)
Lowery, H. J.; Haufler, W. A.
1986-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Data Processing System (DPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison is documented for the Orbiter DPS hardware.
EPA required KCBX to submit samples of the petroleum coke stored at their North and South Chicago terminals to EPA's Chicago Regional Laboratory for analysis of pollutant levels. Results will be compared to coal and pet coke sampled in Detroit.
Yagnik, Gargey B.; Hansen, Rebecca L.; Korte, Andrew R.; ...
2016-08-30
Nanoparticles (NPs) have been suggested as efficient matrixes for small molecule profiling and imaging by laser-desorption ionization mass spectrometry (LDI-MS), but so far there has been no systematic study comparing different NPs in the analysis of various classes of small molecules. Here, we present a large scale screening of 13 NPs for the analysis of two dozen small metabolite molecules. Many NPs showed much higher LDI efficiency than organic matrixes in positive mode and some NPs showed comparable efficiencies for selected analytes in negative mode. Our results suggest that a thermally driven desorption process is a key factor for metalmore » oxide NPs, but chemical interactions are also very important, especially for other NPs. Furthermore, the screening results provide a useful guideline for the selection of NPs in the LDI-MS analysis of small molecules.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yagnik, Gargey B.; Hansen, Rebecca L.; Korte, Andrew R.
Nanoparticles (NPs) have been suggested as efficient matrixes for small molecule profiling and imaging by laser-desorption ionization mass spectrometry (LDI-MS), but so far there has been no systematic study comparing different NPs in the analysis of various classes of small molecules. Here, we present a large scale screening of 13 NPs for the analysis of two dozen small metabolite molecules. Many NPs showed much higher LDI efficiency than organic matrixes in positive mode and some NPs showed comparable efficiencies for selected analytes in negative mode. Our results suggest that a thermally driven desorption process is a key factor for metalmore » oxide NPs, but chemical interactions are also very important, especially for other NPs. Furthermore, the screening results provide a useful guideline for the selection of NPs in the LDI-MS analysis of small molecules.« less
Irimia, Andrei; Richards, William O; Bradshaw, L Alan
2009-11-01
In this study, we perform a comparative study of independent component analysis (ICA) and conventional filtering (CF) for the purpose of artifact reduction from simultaneous gastric EMG and magnetogastrography (MGG). EMG/MGG data were acquired from ten anesthetized pigs by obtaining simultaneous recordings using serosal electrodes (EMG) as well as with a superconducting quantum interference device biomagnetometer (MGG). The analysis of MGG waveforms using ICA and CF indicates that ICA is superior to the CF method in its ability to extract respiration and cardiac artifacts from MGG recordings. A signal frequency analysis of ICA- and CF-processed data was also undertaken using waterfall plots, and it was determined that the two methods produce qualitatively comparable results. Through the use of simultaneous EMG/MGG, we were able to demonstrate the accuracy and trustworthiness of our results by comparison and cross-validation within the framework of a porcine model.
Vibration Signature Analysis of a Faulted Gear Transmission System
NASA Technical Reports Server (NTRS)
Choy, F. K.; Huang, S.; Zakrajsek, J. J.; Handschuh, R. F.; Townsend, D. P.
1994-01-01
A comprehensive procedure in predicting faults in gear transmission systems under normal operating conditions is presented. Experimental data was obtained from a spiral bevel gear fatigue test rig at NASA Lewis Research Center. Time synchronous averaged vibration data was recorded throughout the test as the fault progressed from a small single pit to severe pitting over several teeth, and finally tooth fracture. A numerical procedure based on the Winger-Ville distribution was used to examine the time averaged vibration data. Results from the Wigner-Ville procedure are compared to results from a variety of signal analysis techniques which include time domain analysis methods and frequency analysis methods. Using photographs of the gear tooth at various stages of damage, the limitations and accuracy of the various techniques are compared and discussed. Conclusions are drawn from the comparison of the different approaches as well as the applicability of the Wigner-Ville method in predicting gear faults.
2009-01-01
Background Although features of variable differentiation in glioblastoma cell cultures have been reported, a comparative analysis of differentiation properties of normal neural GFAP positive progenitors, and those shown by glioblastoma cells, has not been performed. Methods Following methods were used to compare glioblastoma cells and GFAP+NNP (NHA): exposure to neural differentiation medium, exposure to adipogenic and osteogenic medium, western blot analysis, immunocytochemistry, single cell assay, BrdU incorporation assay. To characterize glioblastoma cells EGFR amplification analysis, LOH/MSI analysis, and P53 nucleotide sequence analysis were performed. Results In vitro differentiation of cancer cells derived from eight glioblastomas was compared with GFAP-positive normal neural progenitors (GFAP+NNP). Prior to exposure to differentiation medium, both types of cells showed similar multilineage phenotype (CD44+/MAP2+/GFAP+/Vimentin+/Beta III-tubulin+/Fibronectin+) and were positive for SOX-2 and Nestin. In contrast to GFAP+NNP, an efficient differentiation arrest was observed in all cell lines isolated from glioblastomas. Nevertheless, a subpopulation of cells isolated from four glioblastomas differentiated after serum-starvation with varying efficiency into derivatives indistinguishable from the neural derivatives of GFAP+NNP. Moreover, the cells derived from a majority of glioblastomas (7 out of 8), as well as GFAP+NNP, showed features of mesenchymal differentiation when exposed to medium with serum. Conclusion Our results showed that stable co-expression of multilineage markers by glioblastoma cells resulted from differentiation arrest. According to our data up to 95% of glioblastoma cells can present in vitro multilineage phenotype. The mesenchymal differentiation of glioblastoma cells is advanced and similar to mesenchymal differentiation of normal neural progenitors GFAP+NNP. PMID:19216795
Comparative analysis of methods and sources of financing of the transport organizations activity
NASA Astrophysics Data System (ADS)
Gorshkov, Roman
2017-10-01
The article considers the analysis of methods of financing of transport organizations in conditions of limited investment resources. A comparative analysis of these methods is carried out, the classification of investment, methods and sources of financial support for projects being implemented to date are presented. In order to select the optimal sources of financing for the projects, various methods of financial management and financial support for the activities of the transport organization were analyzed, which were considered from the perspective of analysis of advantages and limitations. The result of the study is recommendations on the selection of optimal sources and methods of financing of transport organizations.
An integrated workflow for analysis of ChIP-chip data.
Weigelt, Karin; Moehle, Christoph; Stempfl, Thomas; Weber, Bernhard; Langmann, Thomas
2008-08-01
Although ChIP-chip is a powerful tool for genome-wide discovery of transcription factor target genes, the steps involving raw data analysis, identification of promoters, and correlation with binding sites are still laborious processes. Therefore, we report an integrated workflow for the analysis of promoter tiling arrays with the Genomatix ChipInspector system. We compare this tool with open-source software packages to identify PU.1 regulated genes in mouse macrophages. Our results suggest that ChipInspector data analysis, comparative genomics for binding site prediction, and pathway/network modeling significantly facilitate and enhance whole-genome promoter profiling to reveal in vivo sites of transcription factor-DNA interactions.
Sajjadi, Baharak; Asgharzadehahmadi, Seyedali; Asaithambi, Perumal; Raman, Abdul Aziz Abdul; Parthasarathy, Rajarathinam
2017-01-01
This paper aims at investigating the influence of acoustic streaming induced by low-frequency (24kHz) ultrasound irradiation on mass transfer in a two-phase system. The main objective is to discuss the possible mass transfer improvements under ultrasound irradiation. Three analyses were conducted: i) experimental analysis of mass transfer under ultrasound irradiation; ii) comparative analysis between the results of the ultrasound assisted mass transfer with that obtained from mechanically stirring; and iii) computational analysis of the systems using 3D CFD simulation. In the experimental part, the interactive effects of liquid rheological properties, ultrasound power and superficial gas velocity on mass transfer were investigated in two different sonicators. The results were then compared with that of mechanical stirring. In the computational part, the results were illustrated as a function of acoustic streaming behaviour, fluid flow pattern, gas/liquid volume fraction and turbulence in the two-phase system and finally the mass transfer coefficient was specified. It was found that additional turbulence created by ultrasound played the most important role on intensifying the mass transfer phenomena compared to that in stirred vessel. Furthermore, long residence time which depends on geometrical parameters is another key for mass transfer. The results obtained in the present study would help researchers understand the role of ultrasound as an energy source and acoustic streaming as one of the most important of ultrasound waves on intensifying gas-liquid mass transfer in a two-phase system and can be a breakthrough in the design procedure as no similar studies were found in the existing literature. Copyright © 2016. Published by Elsevier B.V.
Test Cases for Modeling and Validation of Structures with Piezoelectric Actuators
NASA Technical Reports Server (NTRS)
Reaves, Mercedes C.; Horta, Lucas G.
2001-01-01
A set of benchmark test articles were developed to validate techniques for modeling structures containing piezoelectric actuators using commercially available finite element analysis packages. The paper presents the development, modeling, and testing of two structures: an aluminum plate with surface mounted patch actuators and a composite box beam with surface mounted actuators. Three approaches for modeling structures containing piezoelectric actuators using the commercially available packages: MSC/NASTRAN and ANSYS are presented. The approaches, applications, and limitations are discussed. Data for both test articles are compared in terms of frequency response functions from deflection and strain data to input voltage to the actuator. Frequency response function results using the three different analysis approaches provided comparable test/analysis results. It is shown that global versus local behavior of the analytical model and test article must be considered when comparing different approaches. Also, improper bonding of actuators greatly reduces the electrical to mechanical effectiveness of the actuators producing anti-resonance errors.
NASA Technical Reports Server (NTRS)
Kapoor, Kamlesh; Anderson, Bernhard H.; Shaw, Robert J.
1994-01-01
A full Navier-Stokes analysis was performed to evaluate the performance of the subsonic diffuser of a NASA Lewis Research Center 70/30 mixed-compression bifurcated supersonic inlet for high speed civil transport application. The PARC3D code was used in the present study. The computations were also performed when approximately 2.5 percent of the engine mass flow was allowed to bypass through the engine bypass doors. The computational results were compared with the available experimental data which consisted of detailed Mach number and total pressure distribution along the entire length of the subsonic diffuser. The total pressure recovery, flow distortion, and crossflow velocity at the engine face were also calculated. The computed surface ramp and cowl pressure distributions were compared with experiments. Overall, the computational results compared well with experimental data. The present CFD analysis demonstrated that the bypass flow improves the total pressure recovery and lessens flow distortions at the engine face.
Daures, J P; Schved, J F; Momas, I; Gril, J C; Azoulay, P; Gremy, F
1989-01-01
The main reason for using low molecular weight heparin (LMWH) is its capacity to keep the antithrombotic effect of standard non-fractioned heparin (NFH) while reducing its hemorrhagic power. Various studies comparing LMWH to NFH gave contradictory results, so we carried out a meta-analysis of randomized trials comparing these two treatments in prevention of deep-vein thrombosis (DVT) (and in prevention of deep-vein thrombosis or pulmonary embolism). From a selection of ten trials we could not show any significant difference in the DVT rates, as well as for the whole of surgical indications as for the subgroups of abdominal and orthopedic surgery. The weighted global difference between the DVT rates is so low that, in spite of the use of meta-analysis, the power is clearly insufficient. The hemorrhagic risk is not statistically reduced as well for the whole of surgical indications as for the subgroups.
Boyd, Courtney; Crawford, Cindy; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Zhang, Weimin; Buckenmaier, Chester; Buckenmaier, Pamela; Cambron, Jerrilyn; Deery, Christopher; Schwartz, Jan; Werner, Ruth; Whitridge, Pete
2016-01-01
Abstract Purpose Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life in cancer populations. Methods Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using the SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Results Twelve high quality and four low quality studies were subsequently included in the review. Results demonstrate massage therapy is effective for treating pain compared to no treatment [standardized mean difference (SMD) = −.20] and active (SMD = −0.55) comparators. Compared to active comparators, massage therapy was also found to be beneficial for treating fatigue (SMD = −1.06) and anxiety (SMD = −1.24). Conclusion Based on the evidence, weak recommendations are suggested for massage therapy, compared to an active comparator, for the treatment of pain, fatigue, and anxiety. No recommendations were suggested for massage therapy compared to no treatment or sham control based on the available literature to date. This review addresses massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option for cancer pain populations. PMID:27165967
Lee, Hyeongyu; Choi, Yosoon; Suh, Jangwon; Lee, Seung-Ho
2016-01-01
Understanding spatial variation of potentially toxic trace elements (PTEs) in soil is necessary to identify the proper measures for preventing soil contamination at both operating and abandoned mining areas. Many studies have been conducted worldwide to explore the spatial variation of PTEs and to create soil contamination maps using geostatistical methods. However, they generally depend only on inductively coupled plasma atomic emission spectrometry (ICP–AES) analysis data, therefore such studies are limited by insufficient input data owing to the disadvantages of ICP–AES analysis such as its costly operation and lengthy period required for analysis. To overcome this limitation, this study used both ICP–AES and portable X-ray fluorescence (PXRF) analysis data, with relatively low accuracy, for mapping copper and lead concentrations at a section of the Busan abandoned mine in Korea and compared the prediction performances of four different approaches: the application of ordinary kriging to ICP–AES analysis data, PXRF analysis data, both ICP–AES and transformed PXRF analysis data by considering the correlation between the ICP–AES and PXRF analysis data, and co-kriging to both the ICP–AES (primary variable) and PXRF analysis data (secondary variable). Their results were compared using an independent validation data set. The results obtained in this case study showed that the application of ordinary kriging to both ICP–AES and transformed PXRF analysis data is the most accurate approach when considers the spatial distribution of copper and lead contaminants in the soil and the estimation errors at 11 sampling points for validation. Therefore, when generating soil contamination maps for an abandoned mine, it is beneficial to use the proposed approach that incorporates the advantageous aspects of both ICP–AES and PXRF analysis data. PMID:27043594
Lee, Hyeongyu; Choi, Yosoon; Suh, Jangwon; Lee, Seung-Ho
2016-03-30
Understanding spatial variation of potentially toxic trace elements (PTEs) in soil is necessary to identify the proper measures for preventing soil contamination at both operating and abandoned mining areas. Many studies have been conducted worldwide to explore the spatial variation of PTEs and to create soil contamination maps using geostatistical methods. However, they generally depend only on inductively coupled plasma atomic emission spectrometry (ICP-AES) analysis data, therefore such studies are limited by insufficient input data owing to the disadvantages of ICP-AES analysis such as its costly operation and lengthy period required for analysis. To overcome this limitation, this study used both ICP-AES and portable X-ray fluorescence (PXRF) analysis data, with relatively low accuracy, for mapping copper and lead concentrations at a section of the Busan abandoned mine in Korea and compared the prediction performances of four different approaches: the application of ordinary kriging to ICP-AES analysis data, PXRF analysis data, both ICP-AES and transformed PXRF analysis data by considering the correlation between the ICP-AES and PXRF analysis data, and co-kriging to both the ICP-AES (primary variable) and PXRF analysis data (secondary variable). Their results were compared using an independent validation data set. The results obtained in this case study showed that the application of ordinary kriging to both ICP-AES and transformed PXRF analysis data is the most accurate approach when considers the spatial distribution of copper and lead contaminants in the soil and the estimation errors at 11 sampling points for validation. Therefore, when generating soil contamination maps for an abandoned mine, it is beneficial to use the proposed approach that incorporates the advantageous aspects of both ICP-AES and PXRF analysis data.
Life cycle analysis of pistachio production in Greece.
Bartzas, Georgios; Komnitsas, Kostas
2017-10-01
In the present paper, a life cycle assessment (LCA) study regarding pistachio (Pistacia vera L.) cultivation in Aegina island, Greece, was performed to evaluate the energy use footprint and the associated environmental impacts. In this context, a detailed life cycle inventory was created based on site-survey data and used for a holistic cradle-to-farm gate LCA analysis using the GaBi 6.5 software. The main impact categories assessed were acidification potential (AP), eutrophication potential (EP), global warming potential (GWP), ozone depletion potential (ODP), photochemical ozone creation potential (POCP) and cumulative energy demand (CED). In order to reveal the main environmental concerns pertinent to pistachio production and in turn propose measures for the reduction of environmental and energetic impacts, three scenarios were compared, namely the Baseline scenario (BS) that involves current cultivation practices, the Green Energy (GE) scenario that involves the use of biological fertilizers i.e. compost, and the Waste Utilization (WU) scenario that involves the production of biochar from pistachio and other agricultural wastes and its subsequent soil application to promote carbon sequestration and improve soil quality. Based on the results of this study, the use of compost for fertilization (GE scenario), which results in approximately 9% savings in terms of energy consumption and the five environmental impact categories studied compared to BS scenario, is considered a promising alternative cultivation strategy. Slightly higher savings (10% on average) in terms of the five calculated environmental impact categories, compared to the BS scenario, were indicated when the WU scenario was considered. Regarding energy consumption, the WU scenario results in minor increase, 3%, compared to the BS scenario. Results of uncertainty analysis performed using the Monte Carlo technique and contribution analysis showed that GE and WU scenarios offer reliable and significant eco-profile improvements for pistachio production in the study area compared to the current situation. Copyright © 2017 Elsevier B.V. All rights reserved.
The combination of the error correction methods of GAFCHROMIC EBT3 film
Li, Yinghui; Chen, Lixin; Zhu, Jinhan; Liu, Xiaowei
2017-01-01
Purpose The aim of this study was to combine a set of methods for use of radiochromic film dosimetry, including calibration, correction for lateral effects and a proposed triple-channel analysis. These methods can be applied to GAFCHROMIC EBT3 film dosimetry for radiation field analysis and verification of IMRT plans. Methods A single-film exposure was used to achieve dose calibration, and the accuracy was verified based on comparisons with the square-field calibration method. Before performing the dose analysis, the lateral effects on pixel values were corrected. The position dependence of the lateral effect was fitted by a parabolic function, and the curvature factors of different dose levels were obtained using a quadratic formula. After lateral effect correction, a triple-channel analysis was used to reduce disturbances and convert scanned images from films into dose maps. The dose profiles of open fields were measured using EBT3 films and compared with the data obtained using an ionization chamber. Eighteen IMRT plans with different field sizes were measured and verified with EBT3 films, applying our methods, and compared to TPS dose maps, to check correct implementation of film dosimetry proposed here. Results The uncertainty of lateral effects can be reduced to ±1 cGy. Compared with the results of Micke A et al., the residual disturbances of the proposed triple-channel method at 48, 176 and 415 cGy are 5.3%, 20.9% and 31.4% smaller, respectively. Compared with the ionization chamber results, the difference in the off-axis ratio and percentage depth dose are within 1% and 2%, respectively. For the application of IMRT verification, there were no difference between two triple-channel methods. Compared with only corrected by triple-channel method, the IMRT results of the combined method (include lateral effect correction and our present triple-channel method) show a 2% improvement for large IMRT fields with the criteria 3%/3 mm. PMID:28750023
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akinwande, Olaguoke K., E-mail: gokeakin@gmail.com; Philips, Prejesh, E-mail: prejesh.philips@louisville.edu; Duras, Petr, E-mail: durasp@seznam.cz
2015-04-15
PurposeTo compare the feasibility, safety, and efficacy with small and large irinotecan drug-eluting beads (DEBIRI) for treating hepatic colorectal metastases.MethodsUsing our prospectively maintained, multi-center, intra-arterial therapy registry, we identified 196 patients treated with a combination of large beads (100–300 to 500–700 μm) and patients treated with a combination of small beads (70–150 to 100–300 μm). To minimize selection bias, a propensity score analysis was performed to compare both groups.ResultsUnadjusted analysis consisted of 196 and 30 patients treated with large and small beads, respectively. The adjusted analysis consisted of 19 patients each. Unadjusted analysis showed decreased all-grade (p = <0.001) and high-grade adverse effects (p = 0.02)more » in the small bead group, with a persisting trend toward decreased overall side effects in the adjusted analysis favoring small beads (p = 0.09) The adjusted analysis showed the percentage dose delivered (delivered dose/intended dose) was significantly greater in the small bead group compared to the large bead group (96 vs 79 %; p = 0.005). There were also a lower percentage of treatments terminating in complete stasis in the adjusted analysis (0.0035). Adjusted analysis also showed increased objective response rate (ORR) at 12 months (p = 0.04), with a corresponding trend also seen in the unadjusted analysis (0.09).ConclusionSmaller beads result in increased dose delivery probably due to less propensity to reach complete stasis. It may also lead to more durable long-term efficacy. Smaller beads also demonstrate similarly low toxicity compared to large-sized beads with a trend toward less toxicity.« less
Mieczkowski, Tom
2011-03-20
This article examines the conjecture that hair analysis, performed to detect cocaine use or exposure, is biased against African Americans. It does so by comparing the outcomes of 33,928 hair and 105,792 urine samples collected from both African American and white subjects. In making this comparison the analysis seeks to determine if there is a departure in rates of positive and negative outcomes when comparing the results of hair analysis for cocaine to the results from urinalysis for cocaine by racial group. It treats urine as an unbiased test. It compares both the relative ratios of positive outcomes when comparing the two groups and it calculates the relative risk of outcomes for each group for having positive or negative outcomes. The findings show that the ratios of each racial group are effectively same for hair and urine assays, and they also show that the relative risk and risk estimates for positive and negative outcomes are the same for both racial groups. Considering all samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.28 and for urinalysis the risk estimate is 3.10 (Breslow-Day χ(2) .250, 1 df, p = 0.617) a non-significant difference in risk. For pre-employment samples, the cocaine positive risk estimate for the hair samples comparing the two racial groups is 3.10 and for urinalysis the risk estimate is 2.90 (Breslow-Day χ(2) .281, df = 1, p = 0.595), also a non-significant difference in risk. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Cost-effectiveness analysis of acute kidney injury biomarkers in pediatric cardiac surgery.
Petrovic, Stanislava; Bogavac-Stanojevic, Natasa; Lakic, Dragana; Peco-Antic, Amira; Vulicevic, Irena; Ivanisevic, Ivana; Kotur-Stevuljevic, Jelena; Jelic-Ivanovic, Zorana
2015-01-01
Acute kidney injury (AKI) is significant problem in children with congenital heart disease (CHD) who undergo cardiac surgery. The economic impact of a biomarker-based diagnostic strategy for AKI in pediatric populations undergoing CHD surgery is unknown. The aim of this study was to perform the cost effectiveness analysis of using serum cystatin C (sCysC), urine neutrophil gelatinase-associated lipocalin (uNGAL) and urine liver fatty acid-binding protein (uL-FABP) for the diagnosis of AKI in children after cardiac surgery compared with current diagnostic method (monitoring of serum creatinine (sCr) level). We developed a decision analytical model to estimate incremental cost-effectiveness of different biomarker-based diagnostic strategies compared to current diagnostic strategy. The Markov model was created to compare the lifetime cost associated with using of sCysC, uNGAL, uL-FABP with monitoring of sCr level for the diagnosis of AKI. The utility measurement included in the analysis was quality-adjusted life years (QALY). The results of the analysis are presented as the incremental cost-effectiveness ratio (ICER). Analysed biomarker-based diagnostic strategies for AKI were cost-effective compared to current diagnostic method. However, uNGAL and sCys C strategies yielded higher costs and lower effectiveness compared to uL-FABP strategy. uL-FABP added 1.43 QALY compared to current diagnostic method at an additional cost of $8521.87 per patient. Therefore, ICER for uL-FABP compared to sCr was $5959.35/QALY. Our results suggest that the use of uL-FABP would represent cost effective strategy for early diagnosis of AKI in children after cardiac surgery.
Edwards, S J; Lind, T; Lundell, L
2006-09-01
No randomized controlled trial has compared all the licensed standard dose proton pump inhibitors in the healing of reflux oesophagitis. To compare the effectiveness of esomeprazole with licensed standard dose proton pump inhibitors for healing of reflux oesophagitis (i.e. lansoprazole 30 mg, omeprazole 20 mg, pantoprazole 40 mg and rabeprazole 20 mg). Systematic review of CENTRAL, BIOSIS, EMBASE and MEDLINE for randomized controlled trials in patients with reflux oesophagitis. Searching was completed in February 2005. Data on endoscopic healing rates at 4 and 8 weeks were extracted and re-analysed if not analysed by intention-to-treat. Meta-analysis was conducted using a fixed effects model. Of 133 papers identified in the literature search, six were of sufficient quality to be included in the analysis. No studies were identified comparing rabeprazole with esomeprazole. A meta-analysis of healing rates of esomeprazole 40 mg compared with standard dose proton pump inhibitors gave the following results: at 4 weeks [relative risk (RR) 0.92; 95% CI: 0.90, 0.94; P < 0.00001], and 8 weeks (RR 0.95; 95% CI: 0.94, 0.97; P < 0.00001). Publication bias did not have a significant impact on the results. The results were robust to changes in the inclusion/exclusion criteria and using a random effects model. Esomeprazole consistently demonstrates higher healing rates when compared with standard dose proton pump inhibitors.
Adults with reading disabilities: converting a meta-analysis to practice.
Swanson, H Lee
2012-01-01
This article reviews the results of a meta-analysis of the experimental published literature that compares the academic, cognitive, and behavioral performance of adults with reading disabilities (RD) with average achieving adult readers. The meta-analysis shows that deficits independent of the classification measures emerged for adults with RD on measures of vocabulary, math, spelling, and specific cognitive process related to naming speed, phonological processing, and verbal memory. The results also showed that adults with high verbal IQs (scores > 100) but low word recognition standard scores (< 90) yielded greater deficits related to their average reading counterparts when compared to studies that included adults with RD with verbal IQ and reading scores in the same low range. Implications of the findings related to assessment and intervention are discussed.
Wang, Yuan; Bao, Shan; Du, Wenjun; Ye, Zhirui; Sayer, James R
2017-11-17
This article investigated and compared frequency domain and time domain characteristics of drivers' behaviors before and after the start of distracted driving. Data from an existing naturalistic driving study were used. Fast Fourier transform (FFT) was applied for the frequency domain analysis to explore drivers' behavior pattern changes between nondistracted (prestarting of visual-manual task) and distracted (poststarting of visual-manual task) driving periods. Average relative spectral power in a low frequency range (0-0.5 Hz) and the standard deviation in a 10-s time window of vehicle control variables (i.e., lane offset, yaw rate, and acceleration) were calculated and further compared. Sensitivity analyses were also applied to examine the reliability of the time and frequency domain analyses. Results of the mixed model analyses from the time and frequency domain analyses all showed significant degradation in lateral control performance after engaging in visual-manual tasks while driving. Results of the sensitivity analyses suggested that the frequency domain analysis was less sensitive to the frequency bandwidth, whereas the time domain analysis was more sensitive to the time intervals selected for variation calculations. Different time interval selections can result in significantly different standard deviation values, whereas average spectral power analysis on yaw rate in both low and high frequency bandwidths showed consistent results, that higher variation values were observed during distracted driving when compared to nondistracted driving. This study suggests that driver state detection needs to consider the behavior changes during the prestarting periods, instead of only focusing on periods with physical presence of distraction, such as cell phone use. Lateral control measures can be a better indicator of distraction detection than longitudinal controls. In addition, frequency domain analyses proved to be a more robust and consistent method in assessing driving performance compared to time domain analyses.
Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 4
NASA Technical Reports Server (NTRS)
Slaughter, B. C.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 4 contains the IOA analysis worksheets and the NASA FMEA to IOA worksheet cross reference and recommendations.
Comparative analysis of zonal systems for macro-level crash modeling.
Cai, Qing; Abdel-Aty, Mohamed; Lee, Jaeyoung; Eluru, Naveen
2017-06-01
Macro-level traffic safety analysis has been undertaken at different spatial configurations. However, clear guidelines for the appropriate zonal system selection for safety analysis are unavailable. In this study, a comparative analysis was conducted to determine the optimal zonal system for macroscopic crash modeling considering census tracts (CTs), state-wide traffic analysis zones (STAZs), and a newly developed traffic-related zone system labeled traffic analysis districts (TADs). Poisson lognormal models for three crash types (i.e., total, severe, and non-motorized mode crashes) are developed based on the three zonal systems without and with consideration of spatial autocorrelation. The study proposes a method to compare the modeling performance of the three types of geographic units at different spatial configurations through a grid based framework. Specifically, the study region is partitioned to grids of various sizes and the model prediction accuracy of the various macro models is considered within these grids of various sizes. These model comparison results for all crash types indicated that the models based on TADs consistently offer a better performance compared to the others. Besides, the models considering spatial autocorrelation outperform the ones that do not consider it. Based on the modeling results and motivation for developing the different zonal systems, it is recommended using CTs for socio-demographic data collection, employing TAZs for transportation demand forecasting, and adopting TADs for transportation safety planning. The findings from this study can help practitioners select appropriate zonal systems for traffic crash modeling, which leads to develop more efficient policies to enhance transportation safety. Copyright © 2017 Elsevier Ltd and National Safety Council. All rights reserved.
Dietary pattern analysis: a comparison between matched vegetarian and omnivorous subjects.
Clarys, Peter; Deriemaeker, Peter; Huybrechts, Inge; Hebbelinck, Marcel; Mullie, Patrick
2013-06-13
Dietary pattern analysis, based on the concept that foods eaten together are as important as a reductive methodology characterized by a single food or nutrient analysis, has emerged as an alternative approach to study the relation between nutrition and disease. The aim of the present study was to compare nutritional intake and the results of dietary pattern analysis in properly matched vegetarian and omnivorous subjects. Vegetarians (n = 69) were recruited via purposeful sampling and matched non-vegetarians (n = 69) with same age, gender, health and lifestyle characteristics were searched for via convenience sampling. Two dietary pattern analysis methods, the Healthy Eating Index-2010 (HEI-2010) and the Mediterranean Diet Score (MDS) were calculated and analysed in function of the nutrient intake. Mean total energy intake was comparable between vegetarians and omnivorous subjects (p > 0.05). Macronutrient analysis revealed significant differences between the mean values for vegetarians and omnivorous subjects (absolute and relative protein and total fat intake were significantly lower in vegetarians, while carbohydrate and fibre intakes were significantly higher in vegetarians than in omnivorous subjects). The HEI and MDS were significantly higher for the vegetarians (HEI = 53.8.1 ± 11.2; MDS = 4.3 ± 1.3) compared to the omnivorous subjects (HEI = 46.4 ± 15.3; MDS = 3.8 ± 1.4). Our results indicate a more nutrient dense pattern, closer to the current dietary recommendations for the vegetarians compared to the omnivorous subjects. Both indexing systems were able to discriminate between the vegetarians and the non-vegetarians with higher scores for the vegetarian subjects.
ASTROP2 users manual: A program for aeroelastic stability analysis of propfans
NASA Technical Reports Server (NTRS)
Narayanan, G. V.; Kaza, K. R. V.
1991-01-01
A user's manual is presented for the aeroelastic stability and response of propulsion systems computer program called ASTROP2. The ASTROP2 code preforms aeroelastic stability analysis of rotating propfan blades. This analysis uses a two-dimensional, unsteady cascade aerodynamics model and a three-dimensional, normal-mode structural model. Analytical stability results from this code are compared with published experimental results of a rotating composite advanced turboprop model and of nonrotating metallic wing model.
Dimeric spectra analysis in Microsoft Excel: a comparative study.
Gilani, A Ghanadzadeh; Moghadam, M; Zakerhamidi, M S
2011-11-01
The purpose of this work is to introduce the reader to an Add-in implementation, Decom. This implementation provides the whole processing requirements for analysis of dimeric spectra. General linear and nonlinear decomposition algorithms were integrated as an Excel Add-in for easy installation and usage. In this work, the results of several samples investigations were compared to those obtained by Datan. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Witte, Theo; Sâmihaian, Florentina
2013-01-01
This study is a comparative analysis of literary curricula in six European countries and is part of the project LiFT-2, funded by Comenius' Life Long Learning Programme of the European Commission. The result of this project, that involved almost 4,500 teachers, is a European literary framework for secondary education which can be described as a…
Comparative optical analysis of cylindrical solar concentrators.
Durán, J C; Nicolás, R O
1987-02-01
A comparison of the intensity distribution in the receiver plane for five different types of cylindrical concentrators is made. To this end, our previous 2-D optical analysis for nonperfect concentrators with plane receivers is used. Values of the local and mean concentration factors for a characteristic set of parameters of each concentrator are obtained and compared. The results show that the cylindrical-parabolic concentrator attains the highest concentration factors among the concentrators considered.
Elastic-plastic models for multi-site damage
NASA Technical Reports Server (NTRS)
Actis, Ricardo L.; Szabo, Barna A.
1994-01-01
This paper presents recent developments in advanced analysis methods for the computation of stress site damage. The method of solution is based on the p-version of the finite element method. Its implementation was designed to permit extraction of linear stress intensity factors using a superconvergent extraction method (known as the contour integral method) and evaluation of the J-integral following an elastic-plastic analysis. Coarse meshes are adequate for obtaining accurate results supported by p-convergence data. The elastic-plastic analysis is based on the deformation theory of plasticity and the von Mises yield criterion. The model problem consists of an aluminum plate with six equally spaced holes and a crack emanating from each hole. The cracks are of different sizes. The panel is subjected to a remote tensile load. Experimental results are available for the panel. The plasticity analysis provided the same limit load as the experimentally determined load. The results of elastic-plastic analysis were compared with the results of linear elastic analysis in an effort to evaluate how plastic zone sizes influence the crack growth rates. The onset of net-section yielding was determined also. The results show that crack growth rate is accelerated by the presence of adjacent damage, and the critical crack size is shorter when the effects of plasticity are taken into consideration. This work also addresses the effects of alternative stress-strain laws: The elastic-ideally-plastic material model is compared against the Ramberg-Osgood model.
Siéssere, S; de Albuquerque Lima, N; Semprini, M; de Sousa, L G; Paulo Mardegan Issa, J; Aparecida Caldeira Monteiro, S; Cecílio Hallak Regalo, S
2009-11-01
The masseter and temporal muscles of patients with maxillary and mandibular osteoporosis were submitted to electromyographic analysis and compared with a control group. In conclusion, individuals with osteoporosis did not show significantly lower masticatory cycle performance and efficiency compared to the control group during the proposal mastications. This study aimed to examine electromyographically the masseter and temporal muscles of patients with maxillary and mandibular osteoporosis and compare these patients with control patients. Sixty individuals of both genders with an average age of 53.0 +/- 5 years took part in the study, distributed in two groups with 30 individuals each: (1) individuals with osteoporosis; (2) control patients during the habitual and non-habitual mastication. The electromyographic apparel used was a Myosystem-BR1-DataHomins Technology Ltda., with five channels of acquisition and electrodes active differentials. Statistical analysis of the results was performed using SPSS version 15.0 (Chicago, IL, USA). The result of the Student's t test indicated no significant differences (p > 0.05) between the normalized values of the ensemble average obtained in masticatory cycles in both groups. Based on the results of this study, it was concluded that individuals with osteoporosis did not show significantly lower masticatory cycle performance and efficiency compared to control subjects during the habitual and non-habitual mastications. This result is very important because it demonstrates the functionality of the complex physiological process of mastication in individuals with osteoporosis at the bones that compose the face.
Measuring hospital efficiency--comparing four European countries.
Mateus, Céu; Joaquim, Inês; Nunes, Carla
2015-02-01
Performing international comparisons on efficiency usually has two main drawbacks: the lack of comparability of data from different countries and the appropriateness and adequacy of data selected for efficiency measurement. With inpatient discharges for four countries, some of the problems of data comparability usually found in international comparisons were mitigated. The objectives are to assess and compare hospital efficiency levels within and between countries, using stochastic frontier analysis with both cross-sectional and panel data. Data from English (2005-2008), Portuguese (2002-2009), Spanish (2003-2009) and Slovenian (2005-2009) hospital discharges and characteristics are used. Weighted hospital discharges were considered as outputs while the number of employees, physicians, nurses and beds were selected as inputs of the production function. Stochastic frontier analysis using both cross-sectional and panel data were performed, as well as ordinary least squares (OLS) analysis. The adequacy of the data was assessed with Kolmogorov-Smirnov and Breusch-Pagan/Cook-Weisberg tests. Data available results were redundant to perform efficiency measurements using stochastic frontier analysis with cross-sectional data. The likelihood ratio test reveals that in cross-sectional data stochastic frontier analysis (SFA) is not statistically different from OLS in Portuguese data, while SFA and OLS estimates are statistically different for Spanish, Slovenian and English data. In the panel data, the inefficiency term is statistically different from 0 in the four countries in analysis, though for Portugal it is still close to 0. Panel data are preferred over cross-section analysis because results are more robust. For all countries except Slovenia, beds and employees are relevant inputs for the production process. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Mochida, Keiichi; Uehara-Yamaguchi, Yukiko; Yoshida, Takuhiro; Sakurai, Tetsuya; Shinozaki, Kazuo
2011-01-01
Accumulated transcriptome data can be used to investigate regulatory networks of genes involved in various biological systems. Co-expression analysis data sets generated from comprehensively collected transcriptome data sets now represent efficient resources that are capable of facilitating the discovery of genes with closely correlated expression patterns. In order to construct a co-expression network for barley, we analyzed 45 publicly available experimental series, which are composed of 1,347 sets of GeneChip data for barley. On the basis of a gene-to-gene weighted correlation coefficient, we constructed a global barley co-expression network and classified it into clusters of subnetwork modules. The resulting clusters are candidates for functional regulatory modules in the barley transcriptome. To annotate each of the modules, we performed comparative annotation using genes in Arabidopsis and Brachypodium distachyon. On the basis of a comparative analysis between barley and two model species, we investigated functional properties from the representative distributions of the gene ontology (GO) terms. Modules putatively involved in drought stress response and cellulose biogenesis have been identified. These modules are discussed to demonstrate the effectiveness of the co-expression analysis. Furthermore, we applied the data set of co-expressed genes coupled with comparative analysis in attempts to discover potentially Triticeae-specific network modules. These results demonstrate that analysis of the co-expression network of the barley transcriptome together with comparative analysis should promote the process of gene discovery in barley. Furthermore, the insights obtained should be transferable to investigations of Triticeae plants. The associated data set generated in this analysis is publicly accessible at http://coexpression.psc.riken.jp/barley/. PMID:21441235
Müller, Jana Annina; Wendt, Dorothea; Kollmeier, Birger; Brand, Thomas
2016-01-01
The aim of this study was to validate a procedure for performing the audio-visual paradigm introduced by Wendt et al. (2015) with reduced practical challenges. The original paradigm records eye fixations using an eye tracker and calculates the duration of sentence comprehension based on a bootstrap procedure. In order to reduce practical challenges, we first reduced the measurement time by evaluating a smaller measurement set with fewer trials. The results of 16 listeners showed effects comparable to those obtained when testing the original full measurement set on a different collective of listeners. Secondly, we introduced electrooculography as an alternative technique for recording eye movements. The correlation between the results of the two recording techniques (eye tracker and electrooculography) was r = 0.97, indicating that both methods are suitable for estimating the processing duration of individual participants. Similar changes in processing duration arising from sentence complexity were found using the eye tracker and the electrooculography procedure. Thirdly, the time course of eye fixations was estimated with an alternative procedure, growth curve analysis, which is more commonly used in recent studies analyzing eye tracking data. The results of the growth curve analysis were compared with the results of the bootstrap procedure. Both analysis methods show similar processing durations. PMID:27764125
[The kidney transplantation from the ABO-incompatible donors].
Goriaĭnov, V A; Kaabak, M M; Babenko, N N; Shishlo, L A; Morozova, M M; Ragimov, A A; Dashkova, N G; Salimov, É L
2012-01-01
The experience of 28 allotransplantations of ABO-incompatible kidneys was compared with the treatment results of 38 ABO-compatible renal transplantations. The transplanted kidney function, morphological changes of the transplanted kidney and the comparative analysis of actuary survival in both groups showed no significant difference. The results of the study prove the validity of the kidney transplantation from the ABO-incompatible donors.
Villanova, Federica; Di Meglio, Paola; Inokuma, Margaret; Aghaeepour, Nima; Perucha, Esperanza; Mollon, Jennifer; Nomura, Laurel; Hernandez-Fuentes, Maria; Cope, Andrew; Prevost, A Toby; Heck, Susanne; Maino, Vernon; Lord, Graham; Brinkman, Ryan R; Nestle, Frank O
2013-01-01
Discovery of novel immune biomarkers for monitoring of disease prognosis and response to therapy in immune-mediated inflammatory diseases is an important unmet clinical need. Here, we establish a novel framework for immunological biomarker discovery, comparing a conventional (liquid) flow cytometry platform (CFP) and a unique lyoplate-based flow cytometry platform (LFP) in combination with advanced computational data analysis. We demonstrate that LFP had higher sensitivity compared to CFP, with increased detection of cytokines (IFN-γ and IL-10) and activation markers (Foxp3 and CD25). Fluorescent intensity of cells stained with lyophilized antibodies was increased compared to cells stained with liquid antibodies. LFP, using a plate loader, allowed medium-throughput processing of samples with comparable intra- and inter-assay variability between platforms. Automated computational analysis identified novel immunophenotypes that were not detected with manual analysis. Our results establish a new flow cytometry platform for standardized and rapid immunological biomarker discovery with wide application to immune-mediated diseases.
Villanova, Federica; Di Meglio, Paola; Inokuma, Margaret; Aghaeepour, Nima; Perucha, Esperanza; Mollon, Jennifer; Nomura, Laurel; Hernandez-Fuentes, Maria; Cope, Andrew; Prevost, A. Toby; Heck, Susanne; Maino, Vernon; Lord, Graham; Brinkman, Ryan R.; Nestle, Frank O.
2013-01-01
Discovery of novel immune biomarkers for monitoring of disease prognosis and response to therapy in immune-mediated inflammatory diseases is an important unmet clinical need. Here, we establish a novel framework for immunological biomarker discovery, comparing a conventional (liquid) flow cytometry platform (CFP) and a unique lyoplate-based flow cytometry platform (LFP) in combination with advanced computational data analysis. We demonstrate that LFP had higher sensitivity compared to CFP, with increased detection of cytokines (IFN-γ and IL-10) and activation markers (Foxp3 and CD25). Fluorescent intensity of cells stained with lyophilized antibodies was increased compared to cells stained with liquid antibodies. LFP, using a plate loader, allowed medium-throughput processing of samples with comparable intra- and inter-assay variability between platforms. Automated computational analysis identified novel immunophenotypes that were not detected with manual analysis. Our results establish a new flow cytometry platform for standardized and rapid immunological biomarker discovery with wide application to immune-mediated diseases. PMID:23843942
Type 2 diabetes mellitus: distribution of genetic markers in Kazakh population
Sikhayeva, Nurgul; Talzhanov, Yerkebulan; Iskakova, Aisha; Dzharmukhanov, Jarkyn; Nugmanova, Raushan; Zholdybaeva, Elena; Ramanculov, Erlan
2018-01-01
Background Ethnic differences exist in the frequencies of genetic variations that contribute to the risk of common disease. This study aimed to analyse the distribution of several genes, previously associated with susceptibility to type 2 diabetes and obesity-related phenotypes, in a Kazakh population. Methods A total of 966 individuals belonging to the Kazakh ethnicity were recruited from an outpatient clinic. We genotyped 41 common single nucleotide polymorphisms (SNPs) previously associated with type 2 diabetes in other ethnic groups and 31 of these were in Hardy–Weinberg equilibrium. The obtained allele frequencies were further compared to publicly available data from other ethnic populations. Allele frequencies for other (compared) populations were pooled from the haplotype map (HapMap) database. Principal component analysis (PCA), cluster analysis, and multidimensional scaling (MDS) were used for the analysis of genetic relationship between the populations. Results Comparative analysis of allele frequencies of the studied SNPs showed significant differentiation among the studied populations. The Kazakh population was grouped with Asian populations according to the cluster analysis and with the Caucasian populations according to PCA. According to MDS, results of the current study show that the Kazakh population holds an intermediate position between Caucasian and Asian populations. Conclusion A high percentage of population differentiation was observed between Kazakh and world populations. The Kazakh population was clustered with Caucasian populations, and this result may indicate a significant Caucasian component in the Kazakh gene pool. PMID:29551892
Analysis of Synonymous Codon Usage Bias of Zika Virus and Its Adaption to the Hosts
Wang, Hongju; Liu, Siqing; Zhang, Bo
2016-01-01
Zika virus (ZIKV) is a mosquito-borne virus (arbovirus) in the family Flaviviridae, and the symptoms caused by ZIKV infection in humans include rash, fever, arthralgia, myalgia, asthenia and conjunctivitis. Codon usage bias analysis can reveal much about the molecular evolution and host adaption of ZIKV. To gain insight into the evolutionary characteristics of ZIKV, we performed a comprehensive analysis on the codon usage pattern in 46 ZIKV strains by calculating the effective number of codons (ENc), codon adaptation index (CAI), relative synonymous codon usage (RSCU), and other indicators. The results indicate that the codon usage bias of ZIKV is relatively low. Several lines of evidence support the hypothesis that translational selection plays a role in shaping the codon usage pattern of ZIKV. The results from a correspondence analysis (CA) indicate that other factors, such as base composition, aromaticity, and hydrophobicity may also be involved in shaping the codon usage pattern of ZIKV. Additionally, the results from a comparative analysis of RSCU between ZIKV and its hosts suggest that ZIKV tends to evolve codon usage patterns that are comparable to those of its hosts. Moreover, selection pressure from Homo sapiens on the ZIKV RSCU patterns was found to be dominant compared with that from Aedes aegypti and Aedes albopictus. Taken together, both natural translational selection and mutation pressure are important for shaping the codon usage pattern of ZIKV. Our findings contribute to understanding the evolution of ZIKV and its adaption to its hosts. PMID:27893824
Bosse, Hans Martin; Nickel, Martin; Huwendiek, Sören; Schultz, Jobst Hendrik; Nikendei, Christoph
2015-10-24
The few studies directly comparing the methodological approach of peer role play (RP) and standardized patients (SP) for the delivery of communication skills all suggest that both methods are effective. In this study we calculated the costs of both methods (given comparable outcomes) and are the first to generate a differential cost-effectiveness analysis of both methods. Medical students in their prefinal year were randomly assigned to one of two groups receiving communication training in Pediatrics either with RP (N = 34) or 19 individually trained SP (N = 35). In an OSCE with standardized patients using the Calgary-Cambridge Referenced Observation Guide both groups achieved comparable high scores (results published). In this study, corresponding costs were assessed as man-hours resulting from hours of work of SP and tutors. A cost-effectiveness analysis was performed. Cost-effectiveness analysis revealed a major advantage for RP as compared to SP (112 vs. 172 man hours; cost effectiveness ratio .74 vs. .45) at comparable performance levels after training with both methods. While both peer role play and training with standardized patients have their value in medical curricula, RP has a major advantage in terms of cost-effectiveness. This could be taken into account in future decisions.
Carroll, Regina A; Kodak, Tiffany
2014-01-01
The type of procedure used to measure a target behavior may directly influence the perceived treatment outcomes. In the present study, we examined the influence of different data-analysis procedures on the outcomes of two commonly used treatments on the vocal stereotypy of 2 children with an autism spectrum disorder. In Study 1, we compared an interrupted and uninterrupted data-analysis procedure to measure vocal stereotypy during the implementation of response interruption and redirection (RIRD). The results showed that the interrupted data-analysis procedure overestimated the effectiveness of RIRD. In Study 2, we examined the influence of different data-analysis procedures on the interpretation of the relative effects of 2 different treatments for vocal stereotypy. Specifically, we compared interrupted and uninterrupted data-analysis procedures during the implementation of RIRD and noncontingent reinforcement (NCR) as a treatment for vocal stereotypy. The results showed that, as in Study 1, the interrupted data-analysis procedure overestimated the effectiveness of RIRD; however, this effect was not apparent with NCR. These findings suggest that different types of data analysis can influence the perceived success of a treatment. © Society for the Experimental Analysis of Behavior.
Analysis of interior noise ground and flight test data for advanced turboprop aircraft applications
NASA Technical Reports Server (NTRS)
Simpson, M. A.; Tran, B. N.
1991-01-01
Interior noise ground tests conducted on a DC-9 aircraft test section are described. The objectives were to study ground test and analysis techniques for evaluating the effectiveness of interior noise control treatments for advanced turboprop aircraft, and to study the sensitivity of the ground test results to changes in various test conditions. Noise and vibration measurements were conducted under simulated advanced turboprop excitation, for two interior noise control treatment configurations. These ground measurement results were compared with results of earlier UHB (Ultra High Bypass) Demonstrator flight tests with comparable interior treatment configurations. The Demonstrator is an MD-80 test aircraft with the left JT8D engine replaced with a prototype UHB advanced turboprop engine.
Analysis of interior noise ground and flight test data for advanced turboprop aircraft applications
NASA Astrophysics Data System (ADS)
Simpson, M. A.; Tran, B. N.
1991-08-01
Interior noise ground tests conducted on a DC-9 aircraft test section are described. The objectives were to study ground test and analysis techniques for evaluating the effectiveness of interior noise control treatments for advanced turboprop aircraft, and to study the sensitivity of the ground test results to changes in various test conditions. Noise and vibration measurements were conducted under simulated advanced turboprop excitation, for two interior noise control treatment configurations. These ground measurement results were compared with results of earlier UHB (Ultra High Bypass) Demonstrator flight tests with comparable interior treatment configurations. The Demonstrator is an MD-80 test aircraft with the left JT8D engine replaced with a prototype UHB advanced turboprop engine.
Periodic component analysis as a spatial filter for SSVEP-based brain-computer interface.
Kiran Kumar, G R; Reddy, M Ramasubba
2018-06-08
Traditional Spatial filters used for steady-state visual evoked potential (SSVEP) extraction such as minimum energy combination (MEC) require the estimation of the background electroencephalogram (EEG) noise components. Even though this leads to improved performance in low signal to noise ratio (SNR) conditions, it makes such algorithms slow compared to the standard detection methods like canonical correlation analysis (CCA) due to the additional computational cost. In this paper, Periodic component analysis (πCA) is presented as an alternative spatial filtering approach to extract the SSVEP component effectively without involving extensive modelling of the noise. The πCA can separate out components corresponding to a given frequency of interest from the background electroencephalogram (EEG) by capturing the temporal information and does not generalize SSVEP based on rigid templates. Data from ten test subjects were used to evaluate the proposed method and the results demonstrate that the periodic component analysis acts as a reliable spatial filter for SSVEP extraction. Statistical tests were performed to validate the results. The experimental results show that πCA provides significant improvement in accuracy compared to standard CCA and MEC in low SNR conditions. The results demonstrate that πCA provides better detection accuracy compared to CCA and on par with that of MEC at a lower computational cost. Hence πCA is a reliable and efficient alternative detection algorithm for SSVEP based brain-computer interface (BCI). Copyright © 2018. Published by Elsevier B.V.
Li, Wenhua; Yang, Bin; Zhou, Dongmei; Xu, Jun; Ke, Zhi; Suen, Wen-Chen
2016-07-01
Liquid chromatography mass spectrometry (LC-MS) is the most commonly used technique for the characterization of antibody variants. MAb-X and mAb-Y are two approved IgG1 subtype monoclonal antibody drugs recombinantly produced in Chinese hamster ovary (CHO) cells. We report here that two unexpected and rare antibody variants have been discovered during cell culture process development of biosimilars for these two approved drugs through intact mass analysis. We then used comprehensive mass spectrometry-based comparative analysis including reduced light, heavy chains, and domain-specific mass as well as peptide mapping analysis to fully characterize the observed antibody variants. The "middle-up" mass comparative analysis demonstrated that the antibody variant from mAb-X biosimilar candidate was caused by mass variation of antibody crystalline fragment (Fc), whereas a different variant with mass variation in antibody antigen-binding fragment (Fab) from mAb-Y biosimilar candidate was identified. Endoproteinase Lys-C digested peptide mapping and tandem mass spectrometry analysis further revealed that a leucine to glutamine change in N-terminal 402 site of heavy chain was responsible for the generation of mAb-X antibody variant. Lys-C and trypsin coupled non-reduced and reduced peptide mapping comparative analysis showed that the formation of the light-heavy interchain trisulfide bond resulted in the mAb-Y antibody variant. These two cases confirmed that mass spectrometry-based comparative analysis plays a critical role for the characterization of monoclonal antibody variants, and biosimilar developers should start with a comprehensive structural assessment and comparative analysis to decrease the risk of the process development for biosimilars. Copyright © 2016 Elsevier B.V. All rights reserved.
Comparative transcriptomics of early dipteran development
2013-01-01
Background Modern sequencing technologies have massively increased the amount of data available for comparative genomics. Whole-transcriptome shotgun sequencing (RNA-seq) provides a powerful basis for comparative studies. In particular, this approach holds great promise for emerging model species in fields such as evolutionary developmental biology (evo-devo). Results We have sequenced early embryonic transcriptomes of two non-drosophilid dipteran species: the moth midge Clogmia albipunctata, and the scuttle fly Megaselia abdita. Our analysis includes a third, published, transcriptome for the hoverfly Episyrphus balteatus. These emerging models for comparative developmental studies close an important phylogenetic gap between Drosophila melanogaster and other insect model systems. In this paper, we provide a comparative analysis of early embryonic transcriptomes across species, and use our data for a phylogenomic re-evaluation of dipteran phylogenetic relationships. Conclusions We show how comparative transcriptomics can be used to create useful resources for evo-devo, and to investigate phylogenetic relationships. Our results demonstrate that de novo assembly of short (Illumina) reads yields high-quality, high-coverage transcriptomic data sets. We use these data to investigate deep dipteran phylogenetic relationships. Our results, based on a concatenation of 160 orthologous genes, provide support for the traditional view of Clogmia being the sister group of Brachycera (Megaselia, Episyrphus, Drosophila), rather than that of Culicomorpha (which includes mosquitoes and blackflies). PMID:23432914
Comparative analysis of on-orbit dynamic performance of several large antenna concepts
NASA Technical Reports Server (NTRS)
Andersen, G. C.; Garrett, L. B.; Calleson, R. E.
1985-01-01
A comparative analysis of the on-orbit dynamic performance of four large anetanna concepts is presented. Among the antenna concepts evaluated are: the box truss; tetrahedral truss; warp-radial rib; and the hoop and column antenna designs. The characteristics and magnitudes of the antennas' dynamic response were evaluated in terms of structural displacements and member loads incurred during various slew-rate maneuvers. The results of the dynamic response analysis are compared to the design requirements of the Land Mobile Satellite System (LMSS) with respect to surface accuracy, decenter, defocus, and angular rocking. Comments are made on the effectiveness of structural damping and the application of active controls for vibrational response reduction. Schematic illustrations of the antenna design concepts are provided.
Comparative analysis of tumor spheroid generation techniques for differential in vitro drug toxicity
Raghavan, Shreya; Rowley, Katelyn R.; Mehta, Geeta
2016-01-01
Multicellular tumor spheroids are powerful in vitro models to perform preclinical chemosensitivity assays. We compare different methodologies to generate tumor spheroids in terms of resultant spheroid morphology, cellular arrangement and chemosensitivity. We used two cancer cell lines (MCF7 and OVCAR8) to generate spheroids using i) hanging drop array plates; ii) liquid overlay on ultra-low attachment plates; iii) liquid overlay on ultra-low attachment plates with rotating mixing (nutator plates). Analysis of spheroid morphometry indicated that cellular compaction was increased in spheroids generated on nutator and hanging drop array plates. Collagen staining also indicated higher compaction and remodeling in tumor spheroids on nutator and hanging drop arrays compared to conventional liquid overlay. Consequently, spheroids generated on nutator or hanging drop plates had increased chemoresistance to cisplatin treatment (20-60% viability) compared to spheroids on ultra low attachment plates (10-20% viability). Lastly, we used a mathematical model to demonstrate minimal changes in oxygen and cisplatin diffusion within experimentally generated spheroids. Our results demonstrate that in vitro methods of tumor spheroid generation result in varied cellular arrangement and chemosensitivity. PMID:26918944
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.
Hasija, Narender; Bala, Madhu; Goyal, Virender
2014-05-01
Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.
Comparative Microbial Modules Resource: Generation and Visualization of Multi-species Biclusters
Bate, Ashley; Eichenberger, Patrick; Bonneau, Richard
2011-01-01
The increasing abundance of large-scale, high-throughput datasets for many closely related organisms provides opportunities for comparative analysis via the simultaneous biclustering of datasets from multiple species. These analyses require a reformulation of how to organize multi-species datasets and visualize comparative genomics data analyses results. Recently, we developed a method, multi-species cMonkey, which integrates heterogeneous high-throughput datatypes from multiple species to identify conserved regulatory modules. Here we present an integrated data visualization system, built upon the Gaggle, enabling exploration of our method's results (available at http://meatwad.bio.nyu.edu/cmmr.html). The system can also be used to explore other comparative genomics datasets and outputs from other data analysis procedures – results from other multiple-species clustering programs or from independent clustering of different single-species datasets. We provide an example use of our system for two bacteria, Escherichia coli and Salmonella Typhimurium. We illustrate the use of our system by exploring conserved biclusters involved in nitrogen metabolism, uncovering a putative function for yjjI, a currently uncharacterized gene that we predict to be involved in nitrogen assimilation. PMID:22144874
Comparative microbial modules resource: generation and visualization of multi-species biclusters.
Kacmarczyk, Thadeous; Waltman, Peter; Bate, Ashley; Eichenberger, Patrick; Bonneau, Richard
2011-12-01
The increasing abundance of large-scale, high-throughput datasets for many closely related organisms provides opportunities for comparative analysis via the simultaneous biclustering of datasets from multiple species. These analyses require a reformulation of how to organize multi-species datasets and visualize comparative genomics data analyses results. Recently, we developed a method, multi-species cMonkey, which integrates heterogeneous high-throughput datatypes from multiple species to identify conserved regulatory modules. Here we present an integrated data visualization system, built upon the Gaggle, enabling exploration of our method's results (available at http://meatwad.bio.nyu.edu/cmmr.html). The system can also be used to explore other comparative genomics datasets and outputs from other data analysis procedures - results from other multiple-species clustering programs or from independent clustering of different single-species datasets. We provide an example use of our system for two bacteria, Escherichia coli and Salmonella Typhimurium. We illustrate the use of our system by exploring conserved biclusters involved in nitrogen metabolism, uncovering a putative function for yjjI, a currently uncharacterized gene that we predict to be involved in nitrogen assimilation. © 2011 Kacmarczyk et al.
Fatigue Life Analysis of Tapered Hybrid Composite Flexbeams
NASA Technical Reports Server (NTRS)
Murri, Gretchen B.; Schaff, Jeffery R.; Dobyns, Alan L.
2002-01-01
Nonlinear-tapered flexbeam laminates from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. The two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) obtained from the above codes using the virtual crack closure technique (VCCT) at a resin crack location in the flexbeams are presented for both hybrid material types. These results compare well with each other and suggest that the initial delamination growth from the resin crack toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves and compared with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared reasonably well with the test results.
Testing a Wheeled Landing Gear System for the TH-57 Helicopter
1992-12-01
initial comparison was done using a structural analysis program, GIFTS , to simultaneously analyze an~i compare the gear systems. Experimental data was used...15 B. GIFTS PROGRAM RESULTS ............................ 15 1. Model...Element Total System ( GIFTS ) structural analysis program, which is resident oin the Aeiunauimia Euginme1ing Department computer system, an analysis
Regression Analysis: Legal Applications in Institutional Research
ERIC Educational Resources Information Center
Frizell, Julie A.; Shippen, Benjamin S., Jr.; Luna, Andrew L.
2008-01-01
This article reviews multiple regression analysis, describes how its results should be interpreted, and instructs institutional researchers on how to conduct such analyses using an example focused on faculty pay equity between men and women. The use of multiple regression analysis will be presented as a method with which to compare salaries of…
Comparing Active Pediatric Obesity Treatments Using Meta-Analysis
ERIC Educational Resources Information Center
Gilles, Allyson; Cassano, Michael; Shepherd, Elizabeth J.; Higgins, Diana; Hecker, Jeffrey E.; Nangle, Douglas W.
2008-01-01
The current meta-analysis reviews research on the treatment of pediatric obesity focusing on studies that have been published since 1994. Eleven studies (22 comparisons, 115 effect sizes, N = 447) were included in the present meta-analysis. Results indicated that comprehensive behavioral interventions may be improved in at least two ways:…
Fretheim, Atle; Soumerai, Stephen B; Zhang, Fang; Oxman, Andrew D; Ross-Degnan, Dennis
2013-08-01
We reanalyzed the data from a cluster-randomized controlled trial (C-RCT) of a quality improvement intervention for prescribing antihypertensive medication. Our objective was to estimate the effectiveness of the intervention using both interrupted time-series (ITS) and RCT methods, and to compare the findings. We first conducted an ITS analysis using data only from the intervention arm of the trial because our main objective was to compare the findings from an ITS analysis with the findings from the C-RCT. We used segmented regression methods to estimate changes in level or slope coincident with the intervention, controlling for baseline trend. We analyzed the C-RCT data using generalized estimating equations. Last, we estimated the intervention effect by including data from both study groups and by conducting a controlled ITS analysis of the difference between the slope and level changes in the intervention and control groups. The estimates of absolute change resulting from the intervention were ITS analysis, 11.5% (95% confidence interval [CI]: 9.5, 13.5); C-RCT, 9.0% (95% CI: 4.9, 13.1); and the controlled ITS analysis, 14.0% (95% CI: 8.6, 19.4). ITS analysis can provide an effect estimate that is concordant with the results of a cluster-randomized trial. A broader range of comparisons from other RCTs would help to determine whether these are generalizable results. Copyright © 2013 Elsevier Inc. All rights reserved.
Masood, Athar; Stark, Ken D; Salem, Norman
2005-10-01
Conventional sample preparation for fatty acid analysis is a complicated, multiple-step process, and gas chromatography (GC) analysis alone can require >1 h per sample to resolve fatty acid methyl esters (FAMEs). Fast GC analysis was adapted to human plasma FAME analysis using a modified polyethylene glycol column with smaller internal diameters, thinner stationary phase films, increased carrier gas linear velocity, and faster temperature ramping. Our results indicated that fast GC analyses were comparable to conventional GC in peak resolution. A conventional transesterification method based on Lepage and Roy was simplified to a one-step method with the elimination of the neutralization and centrifugation steps. A robotics-amenable method was also developed, with lower methylation temperatures and in an open-tube format using multiple reagent additions. The simplified methods produced results that were quantitatively similar and with similar coefficients of variation as compared with the original Lepage and Roy method. The present streamlined methodology is suitable for the direct fatty acid analysis of human plasma, is appropriate for research studies, and will facilitate large clinical trials and make possible population studies.
NASA Astrophysics Data System (ADS)
Hosseini, Seyed Farhad; Hashemian, Ali; Moetakef-Imani, Behnam; Hadidimoud, Saied
2018-03-01
In the present paper, the isogeometric analysis (IGA) of free-form planar curved beams is formulated based on the nonlinear Timoshenko beam theory to investigate the large deformation of beams with variable curvature. Based on the isoparametric concept, the shape functions of the field variables (displacement and rotation) in a finite element analysis are considered to be the same as the non-uniform rational basis spline (NURBS) basis functions defining the geometry. The validity of the presented formulation is tested in five case studies covering a wide range of engineering curved structures including from straight and constant curvature to variable curvature beams. The nonlinear deformation results obtained by the presented method are compared to well-established benchmark examples and also compared to the results of linear and nonlinear finite element analyses. As the nonlinear load-deflection behavior of Timoshenko beams is the main topic of this article, the results strongly show the applicability of the IGA method to the large deformation analysis of free-form curved beams. Finally, it is interesting to notice that, until very recently, the large deformations analysis of free-form Timoshenko curved beams has not been considered in IGA by researchers.
Meta-Analysis Comparing Zero-Profile Spacer and Anterior Plate in Anterior Cervical Fusion.
Dong, Jun; Lu, Meng; Lu, Teng; Liang, Baobao; Xu, Junkui; Zhou, Jun; Lv, Hongjun; Qin, Jie; Cai, Xuan; Huang, Sihua; Li, Haopeng; Wang, Dong; He, Xijing
2015-01-01
Anterior plate fusion is an effective procedure for the treatment of cervical spinal diseases but is accompanied by a high incidence of postoperative dysphagia. A zero profile (Zero-P) spacer is increasingly being used to reduce postoperative dysphagia and other potential complications associated with surgical intervention. Studies comparing the Zero-P spacer and anterior plate have reported conflicting results. A meta-analysis was conducted to compare the safety, efficacy, radiological outcomes and complications associated with the use of a Zero-P spacer versus an anterior plate in anterior cervical spine fusion for the treatment of cervical spinal disease. We comprehensively searched PubMed, Embase, the Cochrane Library and other databases and performed a meta-analysis of all randomized controlled trials (RCTs) and prospective or retrospective comparative studies assessing the two techniques. Ten studies enrolling 719 cervical spondylosis patients were included. The pooled data showed significant differences in the operation time [SMD = -0.58 (95% CI = -0.77 to 0.40, p < 0.01)] and blood loss [SMD = -0.40, 95% CI (-0.59 to -0.21), p < 0.01] between the two groups. Compared to the anterior plate group, the Zero-P group exhibited a significantly improved JOA score and reduced NDI and VAS. However, anterior plate fusion had greater postoperative segmental and cervical Cobb's angles than the Zero-P group at the last follow-up. The fusion rate in the two groups was similar. More importantly, the Zero-P group had a lower incidence of earlier and later postoperative dysphagia. Compared to anterior plate fusion, Zero-P is a safer and effective procedure, with a similar fusion rate and lower incidence of earlier and later postoperative dysphagia. However, the results of this meta-analysis should be accepted with caution due to the limitations of the study. Further evaluation and large-sample RCTs are required to confirm and update the results of this study.
Land use determination by remote sensor analysis
NASA Technical Reports Server (NTRS)
Mallon, H. J.; Howard, J. Y.
1971-01-01
A land use analysis of 18 selected census tracts in the Metropolitan Washington area using aerial photography was undertaken. A comparison of the results was made with comparable land use data from the Metropolitan Washington Council of Governments' Parcel File, and the results reported. Summary conclusions and recommendations for the use of photo-derived data in land use studies by COG are made.
ERIC Educational Resources Information Center
Rispoli, Mandy J.; Davis, Heather S.; Goodwyn, Fara D.; Camargo, Siglia
2013-01-01
Analogue functional analyses are a well-researched means of determining behavioral function in research and clinical contexts. However, conducting analogue functional analyses in school settings can be problematic and may lead to inconclusive results. The purpose of this study was to compare the results of a trial-based functional analysis with…
Optimization of data analysis for the in vivo neutron activation analysis of aluminum in bone.
Mohseni, H K; Matysiak, W; Chettle, D R; Byun, S H; Priest, N; Atanackovic, J; Prestwich, W V
2016-10-01
An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5μg Al/g Ca) compared to the inverse-variance weighted mean (5.2μg Al/g Ca), rendering both equally applicable to human measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larraga-Gutierrez, J. M.; Ballesteros-Zebadua, P.; Garcia-Garduno, O. A.
2008-08-11
Radiation transmission, leakage and beam penumbra are essential dosimetric parameters related to the commissioning of a multileaf collimation system. This work shows a comparative analysis of commonly used film detectors: X-OMAT V2 and EDR2 radiographic films, and GafChromic EBT registered radiochromic film. The results show that X-OMAT over-estimates radiation leakage and 80-20% beam penumbra. However, according to the reference values reported by the manufacturer for these dosimetric parameters, all three films are adequate for MLC dosimetric characterization, but special care must be taken when X-OMAT V2 film is used due to its low energy photon dependence.
Comparison between two methodologies for urban drainage decision aid.
Moura, P M; Baptista, M B; Barraud, S
2006-01-01
The objective of the present work is to compare two methodologies based on multicriteria analysis for the evaluation of stormwater systems. The first methodology was developed in Brazil and is based on performance-cost analysis, the second one is ELECTRE III. Both methodologies were applied to a case study. Sensitivity and robustness analyses were then carried out. These analyses demonstrate that both methodologies have equivalent results, and present low sensitivity and high robustness. These results prove that the Brazilian methodology is consistent and can be used safely in order to select a good solution or a small set of good solutions that could be compared with more detailed methods afterwards.
Intrachromosomal karyotype asymmetry in Orchidaceae.
Medeiros-Neto, Enoque; Nollet, Felipe; Moraes, Ana Paula; Felix, Leonardo P
2017-01-01
The asymmetry indexes have helped cytotaxonomists to interpret and classify plant karyotypes for species delimitation efforts. However, there is no consensus about the best method to calculate the intrachromosomal asymmetry. The present study aimed to compare different intrachromosomal asymmetry indexes in order to indicate which are more efficient for the estimation of asymmetry in different groups of orchids. Besides, we aimed to compare our results with the Orchidaceae phylogenetic proposal to test the hypothesis of Stebbins (1971). Through a literature review, karyotypes were selected and analyzed comparatively with ideal karyotypes in a cluster analysis. All karyotypes showed some level of interchromosomal asymmetry, ranging from slightly asymmetric to moderately asymmetric. The five tested intrachromosomal asymmetry indexes indicated Sarcoglottis grandiflora as the species with the most symmetrical karyotype and Christensonella pachyphylla with the most asymmetrical karyotype. In the cluster analysis, the largest number of species were grouped with the intermediary ideal karyotypes B or C. Considering our results, we recommend the combined use of at least two indexes, especially Ask% or A1 with Syi, for cytotaxonomic analysis in groups of orchids. In an evolutionary perspective, our results support Stebbins' hypothesis that asymmetric karyotypes derive from a symmetric karyotypes.
Intrachromosomal karyotype asymmetry in Orchidaceae
Medeiros-Neto, Enoque; Nollet, Felipe; Moraes, Ana Paula; Felix, Leonardo P.
2017-01-01
Abstract The asymmetry indexes have helped cytotaxonomists to interpret and classify plant karyotypes for species delimitation efforts. However, there is no consensus about the best method to calculate the intrachromosomal asymmetry. The present study aimed to compare different intrachromosomal asymmetry indexes in order to indicate which are more efficient for the estimation of asymmetry in different groups of orchids. Besides, we aimed to compare our results with the Orchidaceae phylogenetic proposal to test the hypothesis of Stebbins (1971). Through a literature review, karyotypes were selected and analyzed comparatively with ideal karyotypes in a cluster analysis. All karyotypes showed some level of interchromosomal asymmetry, ranging from slightly asymmetric to moderately asymmetric. The five tested intrachromosomal asymmetry indexes indicated Sarcoglottis grandiflora as the species with the most symmetrical karyotype and Christensonella pachyphylla with the most asymmetrical karyotype. In the cluster analysis, the largest number of species were grouped with the intermediary ideal karyotypes B or C. Considering our results, we recommend the combined use of at least two indexes, especially Ask% or A1 with Syi, for cytotaxonomic analysis in groups of orchids. In an evolutionary perspective, our results support Stebbins’ hypothesis that asymmetric karyotypes derive from a symmetric karyotypes. PMID:28644507
Radiation shielding quality assurance
NASA Astrophysics Data System (ADS)
Um, Dallsun
For the radiation shielding quality assurance, the validity and reliability of the neutron transport code MCNP, which is now one of the most widely used radiation shielding analysis codes, were checked with lot of benchmark experiments. And also as a practical example, follows were performed in this thesis. One integral neutron transport experiment to measure the effect of neutron streaming in iron and void was performed with Dog-Legged Void Assembly in Knolls Atomic Power Laboratory in 1991. Neutron flux was measured six different places with the methane detectors and a BF-3 detector. The main purpose of the measurements was to provide benchmark against which various neutron transport calculation tools could be compared. Those data were used in verification of Monte Carlo Neutron & Photon Transport Code, MCNP, with the modeling for that. Experimental results and calculation results were compared in both ways, as the total integrated value of neutron fluxes along neutron energy range from 10 KeV to 2 MeV and as the neutron spectrum along with neutron energy range. Both results are well matched with the statistical error +/-20%. MCNP results were also compared with those of TORT, a three dimensional discrete ordinates code which was developed by Oak Ridge National Laboratory. MCNP results are superior to the TORT results at all detector places except one. This means that MCNP is proved as a very powerful tool for the analysis of neutron transport through iron & air and further it could be used as a powerful tool for the radiation shielding analysis. For one application of the analysis of variance (ANOVA) to neutron and gamma transport problems, uncertainties for the calculated values of critical K were evaluated as in the ANOVA on statistical data.
Comparing digital data processing techniques for surface mine and reclamation monitoring
NASA Technical Reports Server (NTRS)
Witt, R. G.; Bly, B. G.; Campbell, W. J.; Bloemer, H. H. L.; Brumfield, J. O.
1982-01-01
The results of three techniques used for processing Landsat digital data are compared for their utility in delineating areas of surface mining and subsequent reclamation. An unsupervised clustering algorithm (ISOCLS), a maximum-likelihood classifier (CLASFY), and a hybrid approach utilizing canonical analysis (ISOCLS/KLTRANS/ISOCLS) were compared by means of a detailed accuracy assessment with aerial photography at NASA's Goddard Space Flight Center. Results show that the hybrid approach was superior to the traditional techniques in distinguishing strip mined and reclaimed areas.
Gao, Liang; Yang, Lu; Qian, Shengqiang; Tang, Zhuang; Qin, Feng; Wei, Qiang; Han, Ping; Yuan, Jiuhong
2016-01-01
Cryosurgery (CS) has been used on patients with clinically localized PCa for more than 10 years. However, clinical studies evaluating its effectiveness and safety have reported conflicting results. This systematic assessment was performed to obtain comprehensive evidence regarding the potential benefits and safety of CS compared with those of radiotherapy (RT) and radical prostatectomy (RP), respectively. All controlled trials comparing CS with RT or RP and single-arm studies reporting results of CS therapy were identified through comprehensive searches of PubMed, the Cochrane Library and Embase. Ten publications from seven trials, with totally 1252 patients, were included in the meta-analysis, which revealed no significant differences in comparisons of CS vs RT and CS vs RP for overall survival and disease specific survival. However, a significantly lower disease-free survival could be observed for CS than RP. Moreover, a systematic review of literature focusing on comparative data of databases and materials of single-arm trials revealed satisfactory survival results in both primary and salvage CS. Our results showed that cryosurgery would be a relatively effective method for clinically localized prostate cancer with survival results comparable to radiotherapy and radical prostatectomy. However, the large percentage of complications caused by cryosurgery should be carefully monitored. PMID:27271239
Grazing Incidence Optics for X-rays Interferometry
NASA Technical Reports Server (NTRS)
Shipley, Ann; Zissa, David; Cash, Webster; Joy, Marshall
1999-01-01
Grazing incidence mirror parameters and constraints for x-ray interferometry are described. We present interferometer system tolerances and ray trace results used to define mirror surface accuracy requirements. Mirror material, surface figure, roughness, and geometry are evaluated based on analysis results. We also discuss mirror mount design constraints, finite element analysis, environmental issues, and solutions. Challenges associated with quantifying high accuracy mirror surface quality are addressed and test results are compared with theoretical predictions.
Pao, Sheng-Ying; Lin, Win-Li; Hwang, Ming-Jing
2006-01-01
Background Screening for differentially expressed genes on the genomic scale and comparative analysis of the expression profiles of orthologous genes between species to study gene function and regulation are becoming increasingly feasible. Expressed sequence tags (ESTs) are an excellent source of data for such studies using bioinformatic approaches because of the rich libraries and tremendous amount of data now available in the public domain. However, any large-scale EST-based bioinformatics analysis must deal with the heterogeneous, and often ambiguous, tissue and organ terms used to describe EST libraries. Results To deal with the issue of tissue source, in this work, we carefully screened and organized more than 8 million human and mouse ESTs into 157 human and 108 mouse tissue/organ categories, to which we applied an established statistic test using different thresholds of the p value to identify genes differentially expressed in different tissues. Further analysis of the tissue distribution and level of expression of human and mouse orthologous genes showed that tissue-specific orthologs tended to have more similar expression patterns than those lacking significant tissue specificity. On the other hand, a number of orthologs were found to have significant disparity in their expression profiles, hinting at novel functions, divergent regulation, or new ortholog relationships. Conclusion Comprehensive statistics on the tissue-specific expression of human and mouse genes were obtained in this very large-scale, EST-based analysis. These statistical results have been organized into a database, freely accessible at our website , for easy searching of human and mouse tissue-specific genes and for investigating gene expression profiles in the context of comparative genomics. Comparative analysis showed that, although highly tissue-specific genes tend to exhibit similar expression profiles in human and mouse, there are significant exceptions, indicating that orthologous genes, while sharing basic genomic properties, could result in distinct phenotypes. PMID:16626500
Ayad, Essam; Mansy, Mina; Elwi, Dalal; Salem, Mostafa; Salama, Mohamed; Kayser, Klaus
2015-01-01
Optimization of workflow for breast cancer samples with equivocal human epidermal growth factor receptors 2 (HER2)/neu score 2(+) results in routine practice, remains to be a central focus of the on-going efforts to assess HER2 status. According to the College of American Pathologists/American Society of Clinical Oncology guidelines equivocal HER2/neu score 2(+) cases are subject for further testing, usually by fluorescence in situ hybridization (FISH) investigations. It still remains on open question, whether quantitative digital image analysis of HER2 immunohistochemistry (IHC) stained slides can assist in further refining the HER2 score 2(+). To assess utility of quantitative digital analysis of IHC stained slides and compare its performance to FISH in cases of breast cancer with equivocal HER2 score 2(+). Fifteen specimens (previously diagnosed as breast cancer and was evaluated as HER 2(-) score 2(+)) represented the study population. Contemporary new cuts were prepared for re-evaluation of HER2 immunohistochemical studies and FISH examination. All the cases were digitally scanned by iScan (Produced by BioImagene [Now Roche-Ventana]). The IHC signals of HER2 were measured using an automated image analyzing system (MECES, www.Diagnomx.eu/meces). Finally, a comparative study was done between the results of the FISH and the quantitative analysis of the virtual slides. Three out of the 15 cases with equivocal HER2 score 2(+), turned out to be positive (3(+)) by quantitative digital analysis, and 12 were found to be negative in FISH too. Two of these three positive cases proved to be positive with FISH, and only one was negative. Quantitative digital analysis is highly sensitive and relatively specific when compared to FISH in detecting HER2/neu overexpression. Therefore, it represents a potential reliable substitute for FISH in breast cancer cases, which desire further refinement of equivocal IHC results.
Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines
NASA Technical Reports Server (NTRS)
Simonyi, P. S.; Boyle, R. J.
1991-01-01
An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40-50 percent shorter in axial length than conventional state-of-the-art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predicted results from a quasi-3D inviscid and boundary layer analysis, called MTSB (Meridl/Tsonic/Blayer). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.
Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines
NASA Technical Reports Server (NTRS)
Simonyi, P. S.; Boyle, R. J.
1991-01-01
An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40 to 50 percent shorter in axial length than conventional state of the art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predict results from a quasi-3D inviscid and boundary layer analysis, called Meridl/Tsonic/Blayer (MTSB). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.
Allergen Sensitization Pattern by Sex: A Cluster Analysis in Korea.
Ohn, Jungyoon; Paik, Seung Hwan; Doh, Eun Jin; Park, Hyun-Sun; Yoon, Hyun-Sun; Cho, Soyun
2017-12-01
Allergens tend to sensitize simultaneously. Etiology of this phenomenon has been suggested to be allergen cross-reactivity or concurrent exposure. However, little is known about specific allergen sensitization patterns. To investigate the allergen sensitization characteristics according to gender. Multiple allergen simultaneous test (MAST) is widely used as a screening tool for detecting allergen sensitization in dermatologic clinics. We retrospectively reviewed the medical records of patients with MAST results between 2008 and 2014 in our Department of Dermatology. A cluster analysis was performed to elucidate the allergen-specific immunoglobulin (Ig)E cluster pattern. The results of MAST (39 allergen-specific IgEs) from 4,360 cases were analyzed. By cluster analysis, 39items were grouped into 8 clusters. Each cluster had characteristic features. When compared with female, the male group tended to be sensitized more frequently to all tested allergens, except for fungus allergens cluster. The cluster and comparative analysis results demonstrate that the allergen sensitization is clustered, manifesting allergen similarity or co-exposure. Only the fungus cluster allergens tend to sensitize female group more frequently than male group.
Bastide, C; Rozet, F; Salomon, L; Mongiat-Artus, P; Beuzeboc, P; Cormier, L; Eiss, D; Gaschignard, N; Peyromaure, M; Richaud, P; Soulié, M
2010-09-01
Surgical approach for radical prostatectomy is even today a subject of debate in the urologic community. Many comparative studies between retropubic and laparoscopic approach (robotic assisted or not) were reported since 10 years without being able to decide between the supporters of retropubic or laparoscopic approach. The committee of cancer research of the French urological association took hold this question after a recent meta-analysis publication on this subject. Although imperfect, this meta-analysis exists and permits to conclude partially on the advantages and the inconveniences supposed for each surgical approach. Regarding morbidity after radical prostatectomy, the only significant difference reported concerns the hemorrhagic risk in favour of the laparoscopic approach. Regarding oncologic results, the only exploitable data concern positive surgical margins rate, which is identical whatever surgical approach. Concerning the functional results, no difference was reported in the literature between different surgical approaches. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Compression After Impact on Honeycomb Core Sandwich Panels with Thin Facesheets, Part 2: Analysis
NASA Technical Reports Server (NTRS)
Mcquigg, Thomas D.; Kapania, Rakesh K.; Scotti, Stephen J.; Walker, Sandra P.
2012-01-01
A two part research study has been completed on the topic of compression after impact (CAI) of thin facesheet honeycomb core sandwich panels. The research has focused on both experiments and analysis in an effort to establish and validate a new understanding of the damage tolerance of these materials. Part 2, the subject of the current paper, is focused on the analysis, which corresponds to the CAI testings described in Part 1. Of interest, are sandwich panels, with aerospace applications, which consist of very thin, woven S2-fiberglass (with MTM45-1 epoxy) facesheets adhered to a Nomex honeycomb core. Two sets of materials, which were identical with the exception of the density of the honeycomb core, were tested in Part 1. The results highlighted the need for analysis methods which taken into account multiple failure modes. A finite element model (FEM) is developed here, in Part 2. A commercial implementation of the Multicontinuum Failure Theory (MCT) for progressive failure analysis (PFA) in composite laminates, Helius:MCT, is included in this model. The inclusion of PFA in the present model provided a new, unique ability to account for multiple failure modes. In addition, significant impact damage detail is included in the model. A sensitivity study, used to assess the effect of each damage parameter on overall analysis results, is included in an appendix. Analysis results are compared to the experimental results for each of the 32 CAI sandwich panel specimens tested to failure. The failure of each specimen is predicted using the high-fidelity, physicsbased analysis model developed here, and the results highlight key improvements in the understanding of honeycomb core sandwich panel CAI failure. Finally, a parametric study highlights the strength benefits compared to mass penalty for various core densities.
A comparative analysis of selected wastewater pretreatment processes in food industry
NASA Astrophysics Data System (ADS)
Jaszczyszyn, Katarzyna; Góra, Wojciech; Dymaczewski, Zbysław; Borowiak, Robert
2018-02-01
The article presents a comparative analysis of the classical coagulation with the iron sulphate and adsorption on bentonite for the pretreatment of wastewater in the food industry. As a result of the studies, chemical oxygen demand (COD) and total nitrogen (TN) reduction were found to be comparable in both technologies, and a 29% higher total phosphorus removal efficiency by the coagulation was observed. After the coagulation and adsorption processes, a significant difference between mineral and organic fraction in the sludge was found (49% and 51% for bentonite and 28% and 72% for iron sulphate, respectively).
Consequences of common data analysis inaccuracies in CNS trauma injury basic research.
Burke, Darlene A; Whittemore, Scott R; Magnuson, David S K
2013-05-15
The development of successful treatments for humans after traumatic brain or spinal cord injuries (TBI and SCI, respectively) requires animal research. This effort can be hampered when promising experimental results cannot be replicated because of incorrect data analysis procedures. To identify and hopefully avoid these errors in future studies, the articles in seven journals with the highest number of basic science central nervous system TBI and SCI animal research studies published in 2010 (N=125 articles) were reviewed for their data analysis procedures. After identifying the most common statistical errors, the implications of those findings were demonstrated by reanalyzing previously published data from our laboratories using the identified inappropriate statistical procedures, then comparing the two sets of results. Overall, 70% of the articles contained at least one type of inappropriate statistical procedure. The highest percentage involved incorrect post hoc t-tests (56.4%), followed by inappropriate parametric statistics (analysis of variance and t-test; 37.6%). Repeated Measures analysis was inappropriately missing in 52.0% of all articles and, among those with behavioral assessments, 58% were analyzed incorrectly. Reanalysis of our published data using the most common inappropriate statistical procedures resulted in a 14.1% average increase in significant effects compared to the original results. Specifically, an increase of 15.5% occurred with Independent t-tests and 11.1% after incorrect post hoc t-tests. Utilizing proper statistical procedures can allow more-definitive conclusions, facilitate replicability of research results, and enable more accurate translation of those results to the clinic.
Gregori, Josep; Villarreal, Laura; Sánchez, Alex; Baselga, José; Villanueva, Josep
2013-12-16
The microarray community has shown that the low reproducibility observed in gene expression-based biomarker discovery studies is partially due to relying solely on p-values to get the lists of differentially expressed genes. Their conclusions recommended complementing the p-value cutoff with the use of effect-size criteria. The aim of this work was to evaluate the influence of such an effect-size filter on spectral counting-based comparative proteomic analysis. The results proved that the filter increased the number of true positives and decreased the number of false positives and the false discovery rate of the dataset. These results were confirmed by simulation experiments where the effect size filter was used to evaluate systematically variable fractions of differentially expressed proteins. Our results suggest that relaxing the p-value cut-off followed by a post-test filter based on effect size and signal level thresholds can increase the reproducibility of statistical results obtained in comparative proteomic analysis. Based on our work, we recommend using a filter consisting of a minimum absolute log2 fold change of 0.8 and a minimum signal of 2-4 SpC on the most abundant condition for the general practice of comparative proteomics. The implementation of feature filtering approaches could improve proteomic biomarker discovery initiatives by increasing the reproducibility of the results obtained among independent laboratories and MS platforms. Quality control analysis of microarray-based gene expression studies pointed out that the low reproducibility observed in the lists of differentially expressed genes could be partially attributed to the fact that these lists are generated relying solely on p-values. Our study has established that the implementation of an effect size post-test filter improves the statistical results of spectral count-based quantitative proteomics. The results proved that the filter increased the number of true positives whereas decreased the false positives and the false discovery rate of the datasets. The results presented here prove that a post-test filter applying a reasonable effect size and signal level thresholds helps to increase the reproducibility of statistical results in comparative proteomic analysis. Furthermore, the implementation of feature filtering approaches could improve proteomic biomarker discovery initiatives by increasing the reproducibility of results obtained among independent laboratories and MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. Copyright © 2013 Elsevier B.V. All rights reserved.
Boyd, Courtney; Crawford, Cindy; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Zhang, Weimin; Buckenmaier, Chester; Buckenmaier, Pamela; Cambron, Jerrilyn; Deery, Christopher; Schwartz, Jan; Werner, Ruth; Whitridge, Pete
2016-01-01
Abstract Objective Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of the evidence for massage therapy’s efficacy in treating pain, function-related, and health-related quality of life outcomes in surgical pain populations. Methods Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A professionally diverse steering committee interpreted the results to develop recommendations. Results Twelve high quality and four low quality studies were included in the review. Results indicate massage therapy is effective for treating pain [standardized mean difference (SMD) = −0.79] and anxiety (SMD = −0.57) compared to active comparators. Conclusion Based on the available evidence, weak recommendations are suggested for massage therapy, compared to active comparators for reducing pain intensity/severity and anxiety in patients undergoing surgical procedures. This review also discusses massage therapy safety, challenges within this research field, how to address identified research gaps, and next steps for future research. PMID:27165970
Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz
2016-01-01
This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis. PMID:26805819
Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz
2016-01-21
This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.
NASA Technical Reports Server (NTRS)
Brown, K. L.; Bertsch, P. J.
1987-01-01
Results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Electrical Power Generation/Fuel Cell Powerplant (EPG/FCP) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison was provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EPG/FCP hardware.
NASA Technical Reports Server (NTRS)
Quattrochi, D. A.
1984-01-01
An initial analysis of LANDSAT 4 Thematic Mapper (TM) data for the discrimination of agricultural, forested wetland, and urban land covers is conducted using a scene of data collected over Arkansas and Tennessee. A classification of agricultural lands derived from multitemporal LANDSAT Multispectral Scanner (MSS) data is compared with a classification of TM data for the same area. Results from this comparative analysis show that the multitemporal MSS classification produced an overall accuracy of 80.91% while the TM classification yields an overall classification accuracy of 97.06% correct.
NASA Astrophysics Data System (ADS)
Rajshekhar, G.; Gorthi, Sai Siva; Rastogi, Pramod
2010-04-01
For phase estimation in digital holographic interferometry, a high-order instantaneous moments (HIM) based method was recently developed which relies on piecewise polynomial approximation of phase and subsequent evaluation of the polynomial coefficients using the HIM operator. A crucial step in the method is mapping the polynomial coefficient estimation to single-tone frequency determination for which various techniques exist. The paper presents a comparative analysis of the performance of the HIM operator based method in using different single-tone frequency estimation techniques for phase estimation. The analysis is supplemented by simulation results.
Constrained Stochastic Extended Redundancy Analysis.
DeSarbo, Wayne S; Hwang, Heungsun; Stadler Blank, Ashley; Kappe, Eelco
2015-06-01
We devise a new statistical methodology called constrained stochastic extended redundancy analysis (CSERA) to examine the comparative impact of various conceptual factors, or drivers, as well as the specific predictor variables that contribute to each driver on designated dependent variable(s). The technical details of the proposed methodology, the maximum likelihood estimation algorithm, and model selection heuristics are discussed. A sports marketing consumer psychology application is provided in a Major League Baseball (MLB) context where the effects of six conceptual drivers of game attendance and their defining predictor variables are estimated. Results compare favorably to those obtained using traditional extended redundancy analysis (ERA).
Pancholy, Samir B; Sharma, Parikshit S; Pancholy, Dipti S; Patel, Tejas M; Callans, David J; Marchlinski, Francis E
2014-02-01
Studies comparing gender-specific outcomes in patients with atrial fibrillation (AF) have reported conflicting results. Gender differences in cerebrovascular accident/systemic embolism (CVA/SE) or major bleeding outcomes with novel oral anticoagulant (NOAC) use are not known. The goal of this analysis was to perform a systematic review and meta-analysis evaluating gender differences in residual risk of CVA/SE and major bleeding outcomes in patients with nonvalvular AF treated with either warfarin or NOAC. Sixty-four randomized studies were identified using keywords "gender," "AF," and "CVA." Using the Preferred Reporting Items for Systemic Reviews and Meta-analysis method, 6 studies met criteria for inclusion in this meta-analysis. CVA/SE and major bleeding outcomes were separately analyzed in cohorts receiving warfarin and NOAC agents, comparing men with women. Women with AF taking warfarin were at a significantly greater residual risk of CVA/SE compared with men (odds ratio 1.279, 95% confidence interval 1.111 to 1.473, Z = -3.428, p = 0.001). No gender difference in residual risk of CVA/SE was noted in patients with AF receiving NOAC agents (odds ratio 1.146, 95% confidence interval 0.97 to 1.354, p = 0.109). Major bleeding was less frequent in women with AF treated with NOAC. In conclusion, women with AF treated with warfarin have a greater residual risk of CVA/SE and an equivalent major bleeding risk, whereas those treated with NOAC agents deemed superior to warfarin are at equivalent residual risk of CVA/SE and less major bleeding risk compared with men. These results suggest an increased net clinical benefit of NOAC agents compared with warfarin in treating women with AF. Copyright © 2014 Elsevier Inc. All rights reserved.
Independent Orbiter Assessment (IOA): Assessment of the EPD and C/remote manipulator system FMEA/CIL
NASA Technical Reports Server (NTRS)
Robinson, W. W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Electrical Power Distribution and Control (EPD and C)/Remote Manipulator System (RMS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA analysis of the EPD and C/RMS hardware initially generated 345 failure mode worksheets and identified 117 Potential Critical Items (PCIs) before starting the assessment process. These analysis results were compared to the proposed NASA Post 51-L baseline of 132 FMEAs and 66 CIL items.
PSAT: A web tool to compare genomic neighborhoods of multiple prokaryotic genomes
Fong, Christine; Rohmer, Laurence; Radey, Matthew; Wasnick, Michael; Brittnacher, Mitchell J
2008-01-01
Background The conservation of gene order among prokaryotic genomes can provide valuable insight into gene function, protein interactions, or events by which genomes have evolved. Although some tools are available for visualizing and comparing the order of genes between genomes of study, few support an efficient and organized analysis between large numbers of genomes. The Prokaryotic Sequence homology Analysis Tool (PSAT) is a web tool for comparing gene neighborhoods among multiple prokaryotic genomes. Results PSAT utilizes a database that is preloaded with gene annotation, BLAST hit results, and gene-clustering scores designed to help identify regions of conserved gene order. Researchers use the PSAT web interface to find a gene of interest in a reference genome and efficiently retrieve the sequence homologs found in other bacterial genomes. The tool generates a graphic of the genomic neighborhood surrounding the selected gene and the corresponding regions for its homologs in each comparison genome. Homologs in each region are color coded to assist users with analyzing gene order among various genomes. In contrast to common comparative analysis methods that filter sequence homolog data based on alignment score cutoffs, PSAT leverages gene context information for homologs, including those with weak alignment scores, enabling a more sensitive analysis. Features for constraining or ordering results are designed to help researchers browse results from large numbers of comparison genomes in an organized manner. PSAT has been demonstrated to be useful for helping to identify gene orthologs and potential functional gene clusters, and detecting genome modifications that may result in loss of function. Conclusion PSAT allows researchers to investigate the order of genes within local genomic neighborhoods of multiple genomes. A PSAT web server for public use is available for performing analyses on a growing set of reference genomes through any web browser with no client side software setup or installation required. Source code is freely available to researchers interested in setting up a local version of PSAT for analysis of genomes not available through the public server. Access to the public web server and instructions for obtaining source code can be found at . PMID:18366802
Semi-Automated Trajectory Analysis of Deep Ballistic Penetrating Brain Injury
Folio, Les; Solomon, Jeffrey; Biassou, Nadia; Fischer, Tatjana; Dworzak, Jenny; Raymont, Vanessa; Sinaii, Ninet; Wassermann, Eric M.; Grafman, Jordan
2016-01-01
Background Penetrating head injuries (PHIs) are common in combat operations and most have visible wound paths on computed tomography (CT). Objective We assess agreement between an automated trajectory analysis-based assessment of brain injury and manual tracings of encephalomalacia on CT. Methods We analyzed 80 head CTs with ballistic PHI from the Institutional Review Board approved Vietnam head injury registry. Anatomic reports were generated from spatial coordinates of projectile entrance and terminal fragment location. These were compared to manual tracings of the regions of encephalomalacia. Dice’s similarity coefficients, kappa, sensitivities, and specificities were calculated to assess agreement. Times required for case analysis were also compared. Results Results show high specificity of anatomic regions identified on CT with semiautomated anatomical estimates and manual tracings of tissue damage. Radiologist’s and medical students’ anatomic region reports were similar (Kappa 0.8, t-test p < 0.001). Region of probable injury modeling of involved brain structures was sensitive (0.7) and specific (0.9) compared with manually traced structures. Semiautomated analysis was 9-fold faster than manual tracings. Conclusion Our region of probable injury spatial model approximates anatomical regions of encephalomalacia from ballistic PHI with time-saving over manual methods. Results show potential for automated anatomical reporting as an adjunct to current practice of radiologist/neurosurgical review of brain injury by penetrating projectiles. PMID:23707123
Suggestions for presenting the results of data analyses
Anderson, David R.; Link, William A.; Johnson, Douglas H.; Burnham, Kenneth P.
2001-01-01
We give suggestions for the presentation of research results from frequentist, information-theoretic, and Bayesian analysis paradigms, followed by several general suggestions. The information-theoretic and Bayesian methods offer alternative approaches to data analysis and inference compared to traditionally used methods. Guidance is lacking on the presentation of results under these alternative procedures and on nontesting aspects of classical frequentists methods of statistical analysis. Null hypothesis testing has come under intense criticism. We recommend less reporting of the results of statistical tests of null hypotheses in cases where the null is surely false anyway, or where the null hypothesis is of little interest to science or management.
A Fast Fourier transform stochastic analysis of the contaminant transport problem
Deng, F.W.; Cushman, J.H.; Delleur, J.W.
1993-01-01
A three-dimensional stochastic analysis of the contaminant transport problem is developed in the spirit of Naff (1990). The new derivation is more general and simpler than previous analysis. The fast Fourier transformation is used extensively to obtain numerical estimates of the mean concentration and various spatial moments. Data from both the Borden and Cape Cod experiments are used to test the methodology. Results are comparable to results obtained by other methods, and to the experiments themselves.
ATLAS, an integrated structural analysis and design system. Volume 5: System demonstration problems
NASA Technical Reports Server (NTRS)
Samuel, R. A. (Editor)
1979-01-01
One of a series of documents describing the ATLAS System for structural analysis and design is presented. A set of problems is described that demonstrate the various analysis and design capabilities of the ATLAS System proper as well as capabilities available by means of interfaces with other computer programs. Input data and results for each demonstration problem are discussed. Results are compared to theoretical solutions or experimental data where possible. Listings of all input data are included.
Network meta-analysis: an introduction for clinicians.
Rouse, Benjamin; Chaimani, Anna; Li, Tianjing
2017-02-01
Network meta-analysis is a technique for comparing multiple treatments simultaneously in a single analysis by combining direct and indirect evidence within a network of randomized controlled trials. Network meta-analysis may assist assessing the comparative effectiveness of different treatments regularly used in clinical practice and, therefore, has become attractive among clinicians. However, if proper caution is not taken in conducting and interpreting network meta-analysis, inferences might be biased. The aim of this paper is to illustrate the process of network meta-analysis with the aid of a working example on first-line medical treatment for primary open-angle glaucoma. We discuss the key assumption of network meta-analysis, as well as the unique considerations for developing appropriate research questions, conducting the literature search, abstracting data, performing qualitative and quantitative synthesis, presenting results, drawing conclusions, and reporting the findings in a network meta-analysis.
Comparing Visual and Statistical Analysis of Multiple Baseline Design Graphs.
Wolfe, Katie; Dickenson, Tammiee S; Miller, Bridget; McGrath, Kathleen V
2018-04-01
A growing number of statistical analyses are being developed for single-case research. One important factor in evaluating these methods is the extent to which each corresponds to visual analysis. Few studies have compared statistical and visual analysis, and information about more recently developed statistics is scarce. Therefore, our purpose was to evaluate the agreement between visual analysis and four statistical analyses: improvement rate difference (IRD); Tau-U; Hedges, Pustejovsky, Shadish (HPS) effect size; and between-case standardized mean difference (BC-SMD). Results indicate that IRD and BC-SMD had the strongest overall agreement with visual analysis. Although Tau-U had strong agreement with visual analysis on raw values, it had poorer agreement when those values were dichotomized to represent the presence or absence of a functional relation. Overall, visual analysis appeared to be more conservative than statistical analysis, but further research is needed to evaluate the nature of these disagreements.
Wu, Guo Hao; Ehm, Alexandra; Bellone, Marco; Pradelli, Lorenzo
2017-01-01
A prior meta-analysis showed favorable metabolic effects of structured triglyceride (STG) lipid emulsions in surgical and critically ill patients compared with mixed medium-chain/long-chain triglycerides (MCT/LCT) emulsions. Limited data on clinical outcomes precluded pharmacoeconomic analysis. We performed an updated meta-analysis and developed a cost model to compare overall costs for STGs vs MCT/LCTs in Chinese hospitals. We searched Medline, Embase, Wanfang Data, the China Hospital Knowledge Database, and Google Scholar for clinical trials comparing STGs to mixed MCT/LCTs in surgical or critically ill adults published between October 10, 2013 and September 19, 2015. Newly identified studies were pooled with the prior studies and an updated meta-analysis was performed. A deterministic simulation model was used to compare the effects of STGs and mixed MCT/LCT's on Chinese hospital costs. The literature search identified six new trials, resulting in a total of 27 studies in the updated meta-analysis. Statistically significant differences favoring STGs were observed for cumulative nitrogen balance, pre- albumin and albumin concentrations, plasma triglycerides, and liver enzymes. STGs were also associated with a significant reduction in the length of hospital stay (mean difference, -1.45 days; 95% confidence interval, -2.48 to -0.43; p=0.005) versus mixed MCT/LCTs. Cost analysis demonstrated a net cost benefit of ¥675 compared with mixed MCT/LCTs. STGs are associated with improvements in metabolic function and reduced length of hospitalization in surgical and critically ill patients compared with mixed MCT/LCT emulsions. Cost analysis using data from Chinese hospitals showed a corresponding cost benefit.
Relaxation mode analysis of a peptide system: comparison with principal component analysis.
Mitsutake, Ayori; Iijima, Hiromitsu; Takano, Hiroshi
2011-10-28
This article reports the first attempt to apply the relaxation mode analysis method to a simulation of a biomolecular system. In biomolecular systems, the principal component analysis is a well-known method for analyzing the static properties of fluctuations of structures obtained by a simulation and classifying the structures into some groups. On the other hand, the relaxation mode analysis has been used to analyze the dynamic properties of homopolymer systems. In this article, a long Monte Carlo simulation of Met-enkephalin in gas phase has been performed. The results are analyzed by the principal component analysis and relaxation mode analysis methods. We compare the results of both methods and show the effectiveness of the relaxation mode analysis.
Peronard, Jean-Paul
2013-01-01
This article is a comparative analysis between workers in health care with high and low degree of readiness for living technology such as robotics. To explore the differences among workers' readiness, statistical analysis was conducted in a data set obtained from 200 respondents. The results showed important differences between high- and low-readiness types on issues such as staff security, documentation, autonomy, and future challenges.
Verner, Zdeněk; Cermáková, Petra; Skodová, Ingrid; Kováčová, Bianka; Lukeš, Julius; Horváth, Anton
2014-01-01
Trypanosomatids are unicellular parasites living in a wide range of host environments, which to large extent shaped their mitochondrial energy metabolism, resulting in quite large differences even among closely related flagellates. In a comparative manner, we analyzed the activities and composition of mitochondrial respiratory complexes in four species (Leishmania tarentolae, Crithidia fasciculata, Phytomonas serpens and Trypanosoma brucei), which represent the main model trypanosomatids. Moreover, we measured the activity of mitochondrial glycerol-3-phosphate dehydrogenase, the overall oxygen consumption and the mitochondrial membrane potential in each species. The comparative analysis suggests an inverse relationship between the activities of respiratory complexes I and II, as well as the overall activity of the canonical complexes and glycerol-3-phosphate dehydrogenase. Our comparative analysis shows that mitochondrial functions are highly variable in these versatile parasites. Copyright © 2014 Elsevier B.V. All rights reserved.
Independent Orbiter Assessment (IOA): Assessment of the crew equipment subsystem
NASA Technical Reports Server (NTRS)
Saxon, H.; Richard, Bill; Sinclair, S. K.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Crew Equipment hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter Crew Equipment hardware. The IOA product for the Crew Equipment analysis consisted of 352 failure mode worksheets that resulted in 78 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 351 FMEAs and 82 CIL items.
Chieng, Norman; Trnka, Hjalte; Boetker, Johan; Pikal, Michael; Rantanen, Jukka; Grohganz, Holger
2013-09-15
The purpose of this study is to investigate the use of multivariate data analysis for powder X-ray diffraction-pair-wise distribution function (PXRD-PDF) data to detect phase separation in freeze-dried binary amorphous systems. Polymer-polymer and polymer-sugar binary systems at various ratios were freeze-dried. All samples were analyzed by PXRD, transformed to PDF and analyzed by principal component analysis (PCA). These results were validated by differential scanning calorimetry (DSC) through characterization of glass transition of the maximally freeze-concentrate solute (Tg'). Analysis of PXRD-PDF data using PCA provides a more clear 'miscible' or 'phase separated' interpretation through the distribution pattern of samples on a score plot presentation compared to residual plot method. In a phase separated system, samples were found to be evenly distributed around the theoretical PDF profile. For systems that were miscible, a clear deviation of samples away from the theoretical PDF profile was observed. Moreover, PCA analysis allows simultaneous analysis of replicate samples. Comparatively, the phase behavior analysis from PXRD-PDF-PCA method was in agreement with the DSC results. Overall, the combined PXRD-PDF-PCA approach improves the clarity of the PXRD-PDF results and can be used as an alternative explorative data analytical tool in detecting phase separation in freeze-dried binary amorphous systems. Copyright © 2013 Elsevier B.V. All rights reserved.
Plenis, Alina; Olędzka, Ilona; Bączek, Tomasz
2013-05-05
This paper focuses on a comparative study of the column classification system based on the quantitative structure-retention relationships (QSRR method) and column performance in real biomedical analysis. The assay was carried out for the LC separation of moclobemide and its metabolites in human plasma, using a set of 24 stationary phases. The QSRR models established for the studied stationary phases were compared with the column test performance results under two chemometric techniques - the principal component analysis (PCA) and the hierarchical clustering analysis (HCA). The study confirmed that the stationary phase classes found closely related by the QSRR approach yielded comparable separation for moclobemide and its metabolites. Therefore, the QSRR method could be considered supportive in the selection of a suitable column for the biomedical analysis offering the selection of similar or dissimilar columns with a relatively higher certainty. Copyright © 2013 Elsevier B.V. All rights reserved.
The analysis of export commodity competitiveness in Central Java Province at period 2011-2015
NASA Astrophysics Data System (ADS)
Elysi, M. G.; Darsono; Riptanti, E. W.
2018-03-01
This study aims to determine the competitiveness of furniture export in Central Java Province Indonesia in terms of comparative and competitive advantages and to formulate the strategies to enhance the competitiveness of furniture export in Central Java Province. Descriptive analytic method was used for this research. Data used in this research are primary and secondary data. Data were analyzed using RCA (Revealed Comparative Advantage), TSI (Trade Specialization Index) and SOAR (Strength, Opportunity, Aspiration, Result). The results showed that furniture commodity in Central Java Province had strong comparative competitiveness with the value of RCA>1 and had strong competitiveness with positive index values in the range of 0 to 1. Based on SOAR analysis, strategy measures can be formulated, namely maintaining the existing and expanding targeted markets, improving product designs (innovations) and improving raw materials efficiency.
NASA Astrophysics Data System (ADS)
Coronel-Beltrán, Ángel; Álvarez-Borrego, Josué
2010-01-01
We present, in this paper, a comparative analysis of the letters in Times New Roman (TNR), Courier New (CN) and Arial (Ar) font types in plain and italic style and the effects of five foreground/background color combinations using an invariant digital correlation system with a nonlinear filter with k = 0.3. The evaluation of the output plane with this filter is given by the peak-to-correlation energy (PCE) metric. The results show that the letters in TNR font have a better mean PCE value when compared with the CN and Ar fonts. This result is in agreement with some studies on text legibility and for readability where the reaction time (RT) of some participant individuals reading a text is measured. We conclude that the PCE metric is proportional to 1/RT.
Subsonic Analysis of 0.04-Scale F-16XL Models Using an Unstructured Euler Code
NASA Technical Reports Server (NTRS)
Lessard, Wendy B.
1996-01-01
The subsonic flow field about an F-16XL airplane model configuration was investigated with an inviscid unstructured grid technique. The computed surface pressures were compared to wind-tunnel test results at Mach 0.148 for a range of angles of attack from 0 deg to 20 deg. To evaluate the effect of grid dependency on the solution, a grid study was performed in which fine, medium, and coarse grid meshes were generated. The off-surface vortical flow field was locally adapted and showed improved correlation to the wind-tunnel data when compared to the nonadapted flow field. Computational results are also compared to experimental five-hole pressure probe data. A detailed analysis of the off-body computed pressure contours, velocity vectors, and particle traces are presented and discussed.
Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 3
NASA Technical Reports Server (NTRS)
Holden, K. A.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 3 continues the presentation of IOA worksheets and includes the potential critical items list.
Independent Orbiter Assessment (IOA): Assessment of the main propulsion subsystem FMEA/CIL, volume 2
NASA Technical Reports Server (NTRS)
Holden, K. A.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Main Propulsion System (MPS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to available data from the Rockwell Downey/NASA JSC FMEA/CIL review. Volume 2 continues the presentation of IOA worksheets for MPS hardware items.
NASA Technical Reports Server (NTRS)
Long, W. C.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed and analysis of the Communication and Tracking hardware, generating draft failure modes and potential critical items. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter Communication and Tracking hardware. Volume 2 continues the presentation of IOA worksheets.
Leske, David A.; Hatt, Sarah R.; Liebermann, Laura; Holmes, Jonathan M.
2016-01-01
Purpose We compare two methods of analysis for Rasch scoring pre- to postintervention data: Rasch lookup table versus de novo stacked Rasch analysis using the Adult Strabismus-20 (AS-20). Methods One hundred forty-seven subjects completed the AS-20 questionnaire prior to surgery and 6 weeks postoperatively. Subjects were classified 6 weeks postoperatively as “success,” “partial success,” or “failure” based on angle and diplopia status. Postoperative change in AS-20 scores was compared for all four AS-20 domains (self-perception, interactions, reading function, and general function) overall and by success status using two methods: (1) applying historical Rasch threshold measures from lookup tables and (2) performing a stacked de novo Rasch analysis. Change was assessed by analyzing effect size, improvement exceeding 95% limits of agreement (LOA), and score distributions. Results Effect sizes were similar for all AS-20 domains whether obtained from lookup tables or stacked analysis. Similar proportions exceeded 95% LOAs using lookup tables versus stacked analysis. Improvement in median score was observed for all AS-20 domains using lookup tables and stacked analysis (P < 0.0001 for all comparisons). Conclusions The Rasch-scored AS-20 is a responsive and valid instrument designed to measure strabismus-specific health-related quality of life. When analyzing pre- to postoperative change in AS-20 scores, Rasch lookup tables and de novo stacked Rasch analysis yield essentially the same results. Translational Relevance We describe a practical application of lookup tables, allowing the clinician or researcher to score the Rasch-calibrated AS-20 questionnaire without specialized software. PMID:26933524
The BLUEPRINT Data Analysis Portal.
Fernández, José María; de la Torre, Victor; Richardson, David; Royo, Romina; Puiggròs, Montserrat; Moncunill, Valentí; Fragkogianni, Stamatina; Clarke, Laura; Flicek, Paul; Rico, Daniel; Torrents, David; Carrillo de Santa Pau, Enrique; Valencia, Alfonso
2016-11-23
The impact of large and complex epigenomic datasets on biological insights or clinical applications is limited by the lack of accessibility by easy, intuitive, and fast tools. Here, we describe an epigenomics comparative cyber-infrastructure (EPICO), an open-access reference set of libraries to develop comparative epigenomic data portals. Using EPICO, large epigenome projects can make available their rich datasets to the community without requiring specific technical skills. As a first instance of EPICO, we implemented the BLUEPRINT Data Analysis Portal (BDAP). BDAP provides a desktop for the comparative analysis of epigenomes of hematopoietic cell types based on results, such as the position of epigenetic features, from basic analysis pipelines. The BDAP interface facilitates interactive exploration of genomic regions, genes, and pathways in the context of differentiation of hematopoietic lineages. This work represents initial steps toward broadly accessible integrative analysis of epigenomic data across international consortia. EPICO can be accessed at https://github.com/inab, and BDAP can be accessed at http://blueprint-data.bsc.es. Copyright © 2016 Elsevier Inc. All rights reserved.
Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam
2017-01-01
The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t -test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis.
Independent Orbiter Assessment (IOA): Assessment of the extravehicular mobility unit, volume 2
NASA Technical Reports Server (NTRS)
Raffaelli, Gary G.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort performed an independent analysis of the Extravehicular Mobility Unit (EMU) hardware and system, generating draft failure modes criticalities and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the most recent proposed Post 51-L NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison was provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EMU hardware. Volume 2 continues the presentation of IOA analysis worksheets and contains the potential critical items list and NASA FMEA to IOA worksheet cross references and recommendations.
CHAPTER 10: CURRENT TECHNICAL PROBLEMS IN EMERGY ANALYSIS
Technical problems related to the determination of the emergy base for self-organization in environmental systems are considered in this paper. The comparability of emergy analysis results depends on emergy analysts making similar choices in determining the emergy base for a part...
The impact of chimerism in DNA-based forensic sex determination analysis.
George, Renjith; Donald, Preethy Mary; Nagraj, Sumanth Kumbargere; Idiculla, Jose Joy; Hj Ismail, Rashid
2013-01-01
Sex determination is the most important step in personal identification in forensic investigations. DNA-based sex determination analysis is comparatively more reliable than the other conventional methods of sex determination analysis. Advanced technology like real-time polymerase chain reaction (PCR) offers accurate and reproducible results and is at the level of legal acceptance. But still there are situations like chimerism where an individual possess both male and female specific factors together in their body. Sex determination analysis in such cases can give erroneous results. This paper discusses the phenomenon of chimerism and its impact on sex determination analysis in forensic investigations.
Wright, Stuart J; Vass, Caroline M; Sim, Gene; Burton, Michael; Fiebig, Denzil G; Payne, Katherine
2018-02-28
Scale heterogeneity, or differences in the error variance of choices, may account for a significant amount of the observed variation in the results of discrete choice experiments (DCEs) when comparing preferences between different groups of respondents. The aim of this study was to identify if, and how, scale heterogeneity has been addressed in healthcare DCEs that compare the preferences of different groups. A systematic review identified all healthcare DCEs published between 1990 and February 2016. The full-text of each DCE was then screened to identify studies that compared preferences using data generated from multiple groups. Data were extracted and tabulated on year of publication, samples compared, tests for scale heterogeneity, and analytical methods to account for scale heterogeneity. Narrative analysis was used to describe if, and how, scale heterogeneity was accounted for when preferences were compared. A total of 626 healthcare DCEs were identified. Of these 199 (32%) aimed to compare the preferences of different groups specified at the design stage, while 79 (13%) compared the preferences of groups identified at the analysis stage. Of the 278 included papers, 49 (18%) discussed potential scale issues, 18 (7%) used a formal method of analysis to account for scale between groups, and 2 (1%) accounted for scale differences between preference groups at the analysis stage. Scale heterogeneity was present in 65% (n = 13) of studies that tested for it. Analytical methods to test for scale heterogeneity included coefficient plots (n = 5, 2%), heteroscedastic conditional logit models (n = 6, 2%), Swait and Louviere tests (n = 4, 1%), generalised multinomial logit models (n = 5, 2%), and scale-adjusted latent class analysis (n = 2, 1%). Scale heterogeneity is a prevalent issue in healthcare DCEs. Despite this, few published DCEs have discussed such issues, and fewer still have used formal methods to identify and account for the impact of scale heterogeneity. The use of formal methods to test for scale heterogeneity should be used, otherwise the results of DCEs potentially risk producing biased and potentially misleading conclusions regarding preferences for aspects of healthcare.
Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 5
NASA Technical Reports Server (NTRS)
Prust, Chet D.; Hartman, Dan W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 5 contains detailed analysis and superseded analysis worksheets and the NASA FMEA to IOA worksheet cross reference and recommendations.
NASA Technical Reports Server (NTRS)
Long, W. C.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed and analysis of the Communication and Tracking hardware, generating draft failure modes and potential critical items. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter Communication and Tracking hardware. Volume 3 continues the presentation of IOA worksheets and contains the potential critical items list, detailed analysis, and the NASA FMEA to IOA worksheet cross reference and recommendations.
Ko, Dae-Hyun; Ji, Misuk; Kim, Sollip; Cho, Eun-Jung; Lee, Woochang; Yun, Yeo-Min; Chun, Sail; Min, Won-Ki
2016-01-01
The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.
Ceol, M; Forino, M; Gambaro, G; Sauer, U; Schleicher, E D; D'Angelo, A; Anglani, F
2001-01-01
Gene expression can be examined with different techniques including ribonuclease protection assay (RPA), in situ hybridisation (ISH), and quantitative reverse transcription-polymerase chain reaction (RT/PCR). These methods differ considerably in their sensitivity and precision in detecting and quantifying low abundance mRNA. Although there is evidence that RT/PCR can be performed in a quantitative manner, the quantitative capacity of this method is generally underestimated. To demonstrate that the comparative kinetic RT/PCR strategy-which uses a housekeeping gene as internal standard-is a quantitative method to detect significant differences in mRNA levels between different samples, the inhibitory effect of heparin on phorbol 12-myristate 13-acetate (PMA)-induced-TGF-beta1 mRNA expression was evaluated by RT/PCR and RPA, the standard method of mRNA quantification, and the results were compared. The reproducibility of RT/PCR amplification was calculated by comparing the quantity of G3PDH and TGF-beta1 PCR products, generated during the exponential phases, estimated from two different RT/PCR (G3PDH, r = 0.968, P = 0.0000; TGF-beta1, r = 0.966, P = 0.0000). The quantitative capacity of comparative kinetic RT/PCR was demonstrated by comparing the results obtained from RPA and RT/PCR using linear regression analysis. Starting from the same RNA extraction, but using only 1% of the RNA for the RT/PCR compared to RPA, significant correlation was observed (r = 0.984, P = 0.0004). Moreover the morphometric analysis of ISH signal was applied for the semi-quantitative evaluation of the expression and localisation of TGF-beta1 mRNA in the entire cell population. Our results demonstrate the close similarity of the RT/PCR and RPA methods in giving quantitative information on mRNA expression and indicate the possibility to adopt the comparative kinetic RT/PCR as reliable quantitative method of mRNA analysis. Copyright 2001 Wiley-Liss, Inc.
How has problem based learning fared in Pakistan?
Mahmud, Waqas; Hyder, Omar
2012-10-01
To conduct a systematic review of primary research in undergraduate medical education in Pakistan in order to evaluate PBL programs, examine outcomes and competencies influenced by PBL, and compare them with conventional learning (lecture based learning, LBL). Qualitative content analysis. Rawalpindi Medical College, Rawalpindi, from June 2010 - February 2011. Literature was searched using online resources. Studies evaluating outcomes influenced by PBL, or comparing PBL with lecture based learning (LBL) were selected. Due to heterogeneity, a qualitative content analysis was performed in which studies were classified according to the methods of assessment; results were then summarized by outcome and frequencies were calculated. Eleven studies were included. Apart from knowledge acquisition, students gave high ratings to PBL in selected outcomes, alone, and in comparison with LBL. There was a disagreement among results of studies that evaluated knowledge acquisition alone. Based on student perceptions, PBL has many advantages. However, the results of this review are limited due to heterogeneity and methodological weakness of studies, specially the studies that compared exam scores to assess knowledge acquisition.
ERIC Educational Resources Information Center
Wall, Melanie M.; Guo, Jia; Amemiya, Yasuo
2012-01-01
Mixture factor analysis is examined as a means of flexibly estimating nonnormally distributed continuous latent factors in the presence of both continuous and dichotomous observed variables. A simulation study compares mixture factor analysis with normal maximum likelihood (ML) latent factor modeling. Different results emerge for continuous versus…
ERIC Educational Resources Information Center
Shelina, S. L.; Mitina, O. V.
2015-01-01
The article presents the results of an analysis of the moral value judgments of adults (parents, teachers, educators) that directly concern the socialization process of the young generation in the modern metropolis. This paper follows the model study by Jean Piaget that investigated the moral value judgments of children. A comparative analysis of…
Harold W. Wisdom
1990-01-01
Ocean freight rates to Pacific Rim markets for softwood logs, cants, and wood pulp from Alaska were compared with rates from the Puget Sound area by using analysis of covariance and analysis of variance techniques. The results did not support the hypothesis that lower freight rates for Alaska result from shorter shipping distances. In many cases, ocean freight rates...
ERIC Educational Resources Information Center
Van Auken, Stuart; Chrysler, Earl; Wells, Ludmilla Gricenko; Simkin, Mark
2011-01-01
The authors utilized a gap analysis approach to assess general IS knowledge and skill voids or overages in a specific program context. The authors asked alumni to reveal the emphasis that should have been given to 10 IS knowledge and skill areas and compared the results with the emphasis that was actually given. They proceed by relating the…
NASA Technical Reports Server (NTRS)
Kirlik, Alex; Kossack, Merrick Frank
1993-01-01
This status report consists of a thesis entitled 'Ecological Task Analysis: A Method for Display Enhancements.' Previous use of various analysis processes for the purpose of display interface design or enhancement has run the risk of failing to improve user performance due to the analysis resulting in only a sequencial listing of user tasks. Adopting an ecological approach to performing the task analysis, however, may result in the necessary modeling of an unpredictable and variable task domain required to improve user performance. Kirlik has proposed an Ecological Task Analysis framework which is designed for this purpose. It is the purpose of this research to measure this framework's effectiveness at enhancing display interfaces in order to improve user performance. Following the proposed framework, an ecological task analysis of experienced users of a complex and dynamic laboratory task, Star Cruiser, was performed. Based on this analysis, display enhancements were proposed and implemented. An experiment was then conducted to compare this new version of Star Cruiser to the original. By measuring user performance at different tasks, it was determined that during early sessions, use of the enhanced display contributed to better user performance compared to that achieved using the original display. Furthermore, the results indicate that the enhancements proposed as a result of the ecological task analysis affected user performance differently depending on whether they are enhancements which aid in the selection of a possible action or in the performance of an action. Generalizations of these findings to larger, more complex systems were avoided since the analysis was only performed on this one particular system.
NASA Technical Reports Server (NTRS)
Schmeckpeper, K. R.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA first completed an analysis of the Electrical Power Distribution and Control (EPD and C) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EPD and C hardware. The IOA product for the EPD and C analysis consisted of 1671 failure mode analysis worksheets that resulted in 468 potential critical items being identified. Comparison was made to the proposed NASA Post 51-L baseline which consisted of FMEAs and 158 CIL items. Volume 1 contains the EPD and C subsystem description, analysis results, ground rules and assumptions, and some of the IOA worksheets.
Wave power potential in Malaysian territorial waters
NASA Astrophysics Data System (ADS)
Asmida Mohd Nasir, Nor; Maulud, Khairul Nizam Abdul
2016-06-01
Up until today, Malaysia has used renewable energy technology such as biomass, solar and hydro energy for power generation and co-generation in palm oil industries and also for the generation of electricity, yet, we are still far behind other countries which have started to optimize waves for similar production. Wave power is a renewable energy (RE) transported by ocean waves. It is very eco-friendly and is easily reachable. This paper presents an assessment of wave power potential in Malaysian territorial waters including waters of Sabah and Sarawak. In this research, data from Malaysia Meteorology Department (MetMalaysia) is used and is supported by a satellite imaginary obtained from National Aeronautics and Space Administration (NASA) and Malaysia Remote Sensing Agency (ARSM) within the time range of the year 1992 until 2007. There were two types of analyses conducted which were mask analysis and comparative analysis. Mask analysis of a research area is the analysis conducted to filter restricted and sensitive areas. Meanwhile, comparative analysis is an analysis conducted to determine the most potential area for wave power generation. Four comparative analyses which have been carried out were wave power analysis, comparative analysis of wave energy power with the sea topography, hot-spot area analysis and comparative analysis of wave energy with the wind speed. These four analyses underwent clipping processes using Geographic Information System (GIS) to obtain the final result. At the end of this research, the most suitable area to develop a wave energy converter was found, which is in the waters of Terengganu and Sarawak. Besides that, it was concluded that the average potential energy that can be generated in Malaysian territorial waters is between 2.8kW/m to 8.6kW/m.
Crawford, Cindy; Boyd, Courtney; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Yang, EunMee; Zhang, Weimin
2016-07-01
Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of massage therapy research and evidence for its efficacy in treating pain, function-related and health-related quality of life outcomes across all pain populations. Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A diverse steering committee interpreted the results to develop recommendations. Sixty high quality and seven low quality studies were included in the review. Results demonstrate massage therapy effectively treats pain compared to sham [standardized mean difference (SMD) = -.44], no treatment (SMD = -1.14), and active (SMD = -0.26) comparators. Compared to active comparators, massage therapy was also beneficial for treating anxiety (SMD = -0.57) and health-related quality of life (SMD = 0.14). Based on the evidence, massage therapy, compared to no treatment, should be strongly recommended as a pain management option. Massage therapy is weakly recommended for reducing pain, compared to other sham or active comparators, and improving mood and health-related quality of life, compared to other active comparators. Massage therapy safety, research challenges, how to address identified research gaps, and necessary next steps for implementing massage therapy as a viable pain management option are discussed.
Liu, Tong; Yang, Li-Jun; Wang, Li-Jun; Wang, Lang-Ping
2014-02-01
An approach to detecting laser-induced plasma using passive probe was brought up. The plasma of laser welding was studied by using a synchronous electric and spectral information acquisition system, the laser-induced plasma was detected by a passive electric probe and fiber spectrometer, the electrical signal was analyzed on the basis of the theory of plasma sheath, and the temperature of laser-induced plasma was calculated by using the method of relative spectral intensity. The analysis results from electrical signal and spectral one were compared. Calculation results of three kinds of surface circumstances, which were respectively coated by KF, TiO2 and without coating, were compared. The factors affecting the detection accuracy were studied. The results indicated that the results calculated by passive probe matched that by spectral signal basically, and the accuracy was affected by ions mass of the plasma. The designed passive electric probe can be used to reflect the continuous fluctuation of electron temperature of the generated plasma, and monitor the laser-induced plasma.
NASA Technical Reports Server (NTRS)
1976-01-01
Ten advanced energy conversion systems for central-station, based-load electric power generation using coal and coal-derived fuels which were studied by NASA are presented. Various contractors were selected by competitive bidding to study these systems. A comparative evaluation is provided of the contractor results on both a system-by-system and an overall basis. Ground rules specified by NASA, such as coal specifications, fuel costs, labor costs, method of cost comparison, escalation and interest during construction, fixed charges, emission standards, and environmental conditions, are presented. Each system discussion includes the potential advantages of the system, the scope of each contractor's analysis, typical schematics of systems, comparison of cost of electricity and efficiency for each contractor, identification and reconciliation of differences, identification of future improvements, and discussion of outside comments. Considerations common to all systems, such as materials and furnaces, are also discussed. Results of selected in-house analyses are presented, in addition to contractor data. The results for all systems are then compared.
Modified optimal control pilot model for computer-aided design and analysis
NASA Technical Reports Server (NTRS)
Davidson, John B.; Schmidt, David K.
1992-01-01
This paper presents the theoretical development of a modified optimal control pilot model based upon the optimal control model (OCM) of the human operator developed by Kleinman, Baron, and Levison. This model is input compatible with the OCM and retains other key aspects of the OCM, such as a linear quadratic solution for the pilot gains with inclusion of control rate in the cost function, a Kalman estimator, and the ability to account for attention allocation and perception threshold effects. An algorithm designed for each implementation in current dynamic systems analysis and design software is presented. Example results based upon the analysis of a tracking task using three basic dynamic systems are compared with measured results and with similar analyses performed with the OCM and two previously proposed simplified optimal pilot models. The pilot frequency responses and error statistics obtained with this modified optimal control model are shown to compare more favorably to the measured experimental results than the other previously proposed simplified models evaluated.
NASA Astrophysics Data System (ADS)
Xu, Yue-Ping; Yu, Chaofeng; Zhang, Xujie; Zhang, Qingqing; Xu, Xiao
2012-02-01
Hydrological predictions in ungauged basins are of significant importance for water resources management. In hydrological frequency analysis, regional methods are regarded as useful tools in estimating design rainfall/flood for areas with only little data available. The purpose of this paper is to investigate the performance of two regional methods, namely the Hosking's approach and the cokriging approach, in hydrological frequency analysis. These two methods are employed to estimate 24-h design rainfall depths in Hanjiang River Basin, one of the largest tributaries of Yangtze River, China. Validation is made through comparing the results to those calculated from the provincial handbook approach which uses hundreds of rainfall gauge stations. Also for validation purpose, five hypothetically ungauged sites from the middle basin are chosen. The final results show that compared to the provincial handbook approach, the Hosking's approach often overestimated the 24-h design rainfall depths while the cokriging approach most of the time underestimated. Overall, the Hosking' approach produced more accurate results than the cokriging approach.
Entrance and Exit CSR Impedance for Non-Ultrarelativistic Beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Rui; Tsai, Cheng Ying
2017-05-01
For a high-brightness electron beam being transported through beamlines involving bending systems, the coherent synchrotron radiation (CSR) and longitudinal space charge (LSC) interaction could often cause microbunching instability. The semi-analytical Vlasov solver for microbunching gain* depends on the impedances for the relevant collective effects. The existing results for CSR impedances are usually obtained for the ultrarelativistic limit. To extend the microbunching analysis to cases of low energies, such as the case of an ERL merger, or to density modulations at extremely small wavelength, it is necessary to extend the impedance analysis to the non-ultrarelativistic regime. In this study, we presentmore » the impedance analysis for the transient CSR interaction in the non-ultrarelativistic regime, for transients including both entrance to and exit from a magnetic dipole. These impedance results will be compared to their ultra-relativistic counterparts**, and the corresponding wakefield obtained from the impedance for low-energy beams will be compared with the existing results of transient CSR wakefield for general beam energies***.« less
Knepper, Richard; Börner, Katy
2016-01-01
This paper presents the results of a study that compares resource usage with publication output using data about the consumption of CPU cycles from the Extreme Science and Engineering Discovery Environment (XSEDE) and resulting scientific publications for 2,691 institutions/teams. Specifically, the datasets comprise a total of 5,374,032,696 central processing unit (CPU) hours run in XSEDE during July 1, 2011 to August 18, 2015 and 2,882 publications that cite the XSEDE resource. Three types of studies were conducted: a geospatial analysis of XSEDE providers and consumers, co-authorship network analysis of XSEDE publications, and bi-modal network analysis of how XSEDE resources are used by different research fields. Resulting visualizations show that a diverse set of consumers make use of XSEDE resources, that users of XSEDE publish together frequently, and that the users of XSEDE with the highest resource usage tend to be "traditional" high-performance computing (HPC) community members from astronomy, atmospheric science, physics, chemistry, and biology.
Chen, Hai-Hua; Yang, Ji-Long; Lu, Hui-Fang; Zhou, Wei-Jun; Yao, Fei; Deng, Lan
2014-02-01
This study was purposed to investigate the feasibility of high resolution melting (HRM) in the detection of JAK2V617F mutation in patients with myeloproliferative neoplasm (MPN). The 29 marrow samples randomly selected from patients with clinically diagnosed MPN from January 2008 to January 2011 were detected by HRM method. The results of HRM analysis were compared with that detected by allele specific polymerase chain reaction (AS-PCR) and DNA direct sequencing. The results showed that the JAK2V617F mutations were detected in 11 (37.9%, 11/29) cases by HRM, and its comparability with the direct sequencing result was 100%. While the consistency of AS-PCR with the direct sequencing was moderate (Kappa = 0.179, P = 0.316). It is concluded that the HRM analysis may be an optimal method for clinical screening of JAK2V617F mutation due to its simplicity and promptness with a high specificity.
Meta-analysis of Laparoscopic Versus Open Repair of Perforated Peptic Ulcer
Antoniou, George A.; Koch, Oliver O.; Pointner, Rudolph; Granderath, Frank A.
2013-01-01
Background and Objectives: Laparoscopic treatment of perforated peptic ulcer (PPU) has been introduced as an alternative procedure to open surgery. It has been postulated that the minimally invasive approach involves less operative stress and results in decreased morbidity and mortality. Methods: We conducted a meta-analysis of randomized trials to test this hypothesis. Medline, EMBASE, and the Cochrane Central Register of Randomized Trials databases were searched, with no date or language restrictions. Results: Our literature search identified 4 randomized trials, with a cumulative number of 289 patients, that compared the laparoscopic approach with open sutured repair of perforated ulcer. Analysis of outcomes did not favor either approach in terms of morbidity, mortality, and reoperation rate, although odds ratios seemed to consistently support the laparoscopic approach. Results did not determine the comparative efficiency and safety of laparoscopic or open approach for PPU. Conclusion: In view of an increased interest in the laparoscopic approach, further randomized trials are considered essential to determine the relative effectiveness of laparoscopic and open repair of PPU. PMID:23743368
BactoGeNIE: a large-scale comparative genome visualization for big displays
2015-01-01
Background The volume of complete bacterial genome sequence data available to comparative genomics researchers is rapidly increasing. However, visualizations in comparative genomics--which aim to enable analysis tasks across collections of genomes--suffer from visual scalability issues. While large, multi-tiled and high-resolution displays have the potential to address scalability issues, new approaches are needed to take advantage of such environments, in order to enable the effective visual analysis of large genomics datasets. Results In this paper, we present Bacterial Gene Neighborhood Investigation Environment, or BactoGeNIE, a novel and visually scalable design for comparative gene neighborhood analysis on large display environments. We evaluate BactoGeNIE through a case study on close to 700 draft Escherichia coli genomes, and present lessons learned from our design process. Conclusions BactoGeNIE accommodates comparative tasks over substantially larger collections of neighborhoods than existing tools and explicitly addresses visual scalability. Given current trends in data generation, scalable designs of this type may inform visualization design for large-scale comparative research problems in genomics. PMID:26329021
Study of Selected Composites Copper Concentrate-Plastic Waste Using Thermal Analysis
NASA Astrophysics Data System (ADS)
Szyszka, Danuta
2017-12-01
The paper presents thermal analysis of selected composites (copper concentrate, plastic waste) in two stages. The first stage consisted in thermogravimetric analysis and differential thermal analysis on the applied plastic waste and copper concentrate, and subsequently, a comparative study has been carried out on products obtained, constituting composites of those materials. As a result of analyses, it was found that up to ca. 400 °C composites show high thermal stability, whereas above that temperature, a thermal decomposition of the composite occurs, resulting in emissions of organic compounds, i.e. hydrocarbon compounds and organic oxygenate derivatives.
A Comparative Analysis for Wilderness User Fee Policy.
ERIC Educational Resources Information Center
Leuschner, William A.; And Others
1987-01-01
Two similar wilderness areas, one of which charges user fees, were sampled in order to compare user characteristics, trip characteristics, and travel cost demand functions. The purpose was to examine the effect fees had on user behavior and choices of area. Results are presented. (MT)
Zelenina, D A; Khrustaleva, A M; Volkov, A A
2006-05-01
Using two types of molecular markers, a comparative analysis of the population structure of sockeye salmon from West Kamchatka as well as population assignment of each individual fish were carried out. The values of a RAPD-PCR-based population assignment test (94-100%) were somewhat higher than those based on microsatellite data (74-84%). However, these results seem quite satisfactory because of high polymorphism of the microsatellite loci examined. The UPGMA dendrograms of genetic similarity of three largest spawning populations, constructed using each of the methods, were highly reliable, which was demonstrated by high bootstrap indices (100% in the case of RAPD-PCR; 84 and 100%, in the case of microsatellite analysis), though the resultant trees differed from one another. The different topology of the trees, in our view, is explained by the fact that the employed methods explored different parts of the genome; hence, the obtained results, albeit valid, may not correlate. Thus, to enhance reliability of the results, several methods of analysis should be used concurrently.
Neutronics Conversion Analyses of the Laue-Langevin Institute (ILL) High Flux Reactor (RHF)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergeron, A.; Dionne, B.; Calzavara, Y.
2014-09-30
The following report describes the neutronics results obtained with the MCNP model of the RHF U7Mo LEU reference design that has been established in 2010 during the feasibility analysis. This work constitutes a complete and detailed neutronics analysis of that LEU design using models that have been significantly improved since 2010 and the release of the feasibility report. When possible, the credibility of the neutronics model is tested by comparing the HEU model results with experimental data or other codes calculations results. The results obtained with the LEU model are systematically compared to the HEU model. The changes applied tomore » the neutronics model lead to better comparisons with experimental data or improved the calculation efficiency but do not challenge the conclusion of the feasibility analysis. If the U7Mo fuel is commercially available, not cost prohibitive, a back-end solution is established and if it is possible to manufacture the proposed element, neutronics analyses show that the performance of the reactor would not be challenged by the conversion to LEU fuel.« less
NASA Technical Reports Server (NTRS)
Chwalowski, Pawel; Florance, Jennifer P.; Heeg, Jennifer; Wieseman, Carol D.; Perry, Boyd P.
2011-01-01
This paper presents preliminary computational aeroelastic analysis results generated in preparation for the first Aeroelastic Prediction Workshop (AePW). These results were produced using FUN3D software developed at NASA Langley and are compared against the experimental data generated during the HIgh REynolds Number Aero- Structural Dynamics (HIRENASD) Project. The HIRENASD wind-tunnel model was tested in the European Transonic Windtunnel in 2006 by Aachen University0s Department of Mechanics with funding from the German Research Foundation. The computational effort discussed here was performed (1) to obtain a preliminary assessment of the ability of the FUN3D code to accurately compute physical quantities experimentally measured on the HIRENASD model and (2) to translate the lessons learned from the FUN3D analysis of HIRENASD into a set of initial guidelines for the first AePW, which includes test cases for the HIRENASD model and its experimental data set. This paper compares the computational and experimental results obtained at Mach 0.8 for a Reynolds number of 7 million based on chord, corresponding to the HIRENASD test conditions No. 132 and No. 159. Aerodynamic loads and static aeroelastic displacements are compared at two levels of the grid resolution. Harmonic perturbation numerical results are compared with the experimental data using the magnitude and phase relationship between pressure coefficients and displacement. A dynamic aeroelastic numerical calculation is presented at one wind-tunnel condition in the form of the time history of the generalized displacements. Additional FUN3D validation results are also presented for the AGARD 445.6 wing data set. This wing was tested in the Transonic Dynamics Tunnel and is commonly used in the preliminary benchmarking of computational aeroelastic software.
Dual-echo ASL based assessment of motor networks: a feasibility study
NASA Astrophysics Data System (ADS)
Storti, Silvia Francesca; Boscolo Galazzo, Ilaria; Pizzini, Francesca B.; Menegaz, Gloria
2018-04-01
Objective. Dual-echo arterial spin labeling (DE-ASL) technique has been recently proposed for the simultaneous acquisition of ASL and blood-oxygenation-level-dependent (BOLD)-functional magnetic resonance imaging (fMRI) data. The assessment of this technique in detecting functional connectivity at rest or during motor and motor imagery tasks is still unexplored both per-se and in comparison with conventional methods. The purpose is to quantify the sensitivity of the DE-ASL sequence with respect to the conventional fMRI sequence (cvBOLD) in detecting brain activations, and to assess and compare the relevance of node features in decoding the network structure. Approach. Thirteen volunteers were scanned acquiring a pseudo-continuous DE-ASL sequence from which the concomitant BOLD (ccBOLD) simultaneously to the ASL can be extracted. The approach consists of two steps: (i) model-based analyses for assessing brain activations at individual and group levels, followed by statistical analysis for comparing the activation elicited by the three sequences under two conditions (motor and motor imagery), respectively; (ii) brain connectivity graph-theoretical analysis for assessing and comparing the network models properties. Main results. Our results suggest that cvBOLD and ccBOLD have comparable sensitivity in detecting the regions involved in the active task, whereas ASL offers a higher degree of co-localization with smaller activation volumes. The connectivity results and the comparative analysis of node features across sequences revealed that there are no strong changes between rest and tasks and that the differences between the sequences are limited to few connections. Significance. Considering the comparable sensitivity of the ccBOLD and cvBOLD sequences in detecting activated brain regions, the results demonstrate that DE-ASL can be successfully applied in functional studies allowing to obtain both ASL and BOLD information within a single sequence. Further, DE-ASL is a powerful technique for research and clinical applications allowing to perform quantitative comparisons as well as to characterize functional connectivity.
Giménez-Espert, María Del Carmen; Prado-Gascó, Vicente Javier
2018-03-01
To analyse link between empathy and emotional intelligence as a predictor of nurses' attitudes towards communication while comparing the contribution of emotional aspects and attitudinal elements on potential behaviour. Nurses' attitudes towards communication, empathy and emotional intelligence are key skills for nurses involved in patient care. There are currently no studies analysing this link, and its investigation is needed because attitudes may influence communication behaviours. Correlational study. To attain this goal, self-reported instruments (attitudes towards communication of nurses, trait emotional intelligence (Trait Emotional Meta-Mood Scale) and Jefferson Scale of Nursing Empathy (Jefferson Scale Nursing Empathy) were collected from 460 nurses between September 2015-February 2016. Two different analytical methodologies were used: traditional regression models and fuzzy-set qualitative comparative analysis models. The results of the regression model suggest that cognitive dimensions of attitude are a significant and positive predictor of the behavioural dimension. The perspective-taking dimension of empathy and the emotional-clarity dimension of emotional intelligence were significant positive predictors of the dimensions of attitudes towards communication, except for the affective dimension (for which the association was negative). The results of the fuzzy-set qualitative comparative analysis models confirm that the combination of high levels of cognitive dimension of attitudes, perspective-taking and emotional clarity explained high levels of the behavioural dimension of attitude. Empathy and emotional intelligence are predictors of nurses' attitudes towards communication, and the cognitive dimension of attitude is a good predictor of the behavioural dimension of attitudes towards communication of nurses in both regression models and fuzzy-set qualitative comparative analysis. In general, the fuzzy-set qualitative comparative analysis models appear to be better predictors than the regression models are. To evaluate current practices, establish intervention strategies and evaluate their effectiveness. The evaluation of these variables and their relationships are important in creating a satisfied and sustainable workforce and improving quality of care and patient health. © 2018 John Wiley & Sons Ltd.
Wang, Wenyu; Liu, Yang; Hao, Jingcan; Zheng, Shuyu; Wen, Yan; Xiao, Xiao; He, Awen; Fan, Qianrui; Zhang, Feng; Liu, Ruiyu
2016-10-10
Hip cartilage destruction is consistently observed in the non-traumatic osteonecrosis of femoral head (NOFH) and accelerates its bone necrosis. The molecular mechanism underlying the cartilage damage of NOFH remains elusive. In this study, we conducted a systematically comparative study of gene expression profiles between NOFH and osteoarthritis (OA). Hip articular cartilage specimens were collected from 12 NOFH patients and 12 controls with traumatic femoral neck fracture for microarray (n=4) and quantitative real-time PCR validation experiments (n=8). Gene expression profiling of articular cartilage was performed using Agilent Human 4×44K Microarray chip. The accuracy of microarray experiment was further validated by qRT-PCR. Gene expression results of OA hip cartilage were derived from previously published study. Significance Analysis of Microarrays (SAM) software was applied for identifying differently expressed genes. Gene ontology (GO) and pathway enrichment analysis were conducted by Gene Set Enrichment Analysis software and DAVID tool, respectively. Totally, 27 differently expressed genes were identified for NOFH. Comparing the gene expression profiles of NOFH cartilage and OA cartilage detected 8 common differently expressed genes, including COL5A1, OGN, ANGPTL4, CRIP1, NFIL3, METRNL, ID2 and STEAP1. GO comparative analysis identified 10 common significant GO terms, mainly implicated in apoptosis and development process. Pathway comparative analysis observed that ECM-receptor interaction pathway and focal adhesion pathway were enriched in the differently expressed genes of both NOFH and hip OA. In conclusion, we identified a set of differently expressed genes, GO and pathways for NOFH articular destruction, some of which were also involved in the hip OA. Our study results may help to reveal the pathogenetic similarities and differences of cartilage damage of NOFH and hip OA. Copyright © 2016 Elsevier B.V. All rights reserved.
Lobb, Eric C
2016-07-08
Version 6.3 of the RITG148+ software package offers eight automated analysis routines for quality assurance of the TomoTherapy platform. A performance evaluation of each routine was performed in order to compare RITG148+ results with traditionally accepted analysis techniques and verify that simulated changes in machine parameters are correctly identified by the software. Reference films were exposed according to AAPM TG-148 methodology for each routine and the RITG148+ results were compared with either alternative software analysis techniques or manual analysis techniques in order to assess baseline agreement. Changes in machine performance were simulated through translational and rotational adjustments to subsequently irradiated films, and these films were analyzed to verify that the applied changes were accurately detected by each of the RITG148+ routines. For the Hounsfield unit routine, an assessment of the "Frame Averaging" functionality and the effects of phantom roll on the routine results are presented. All RITG148+ routines reported acceptable baseline results consistent with alternative analysis techniques, with 9 of the 11 baseline test results showing agreement of 0.1mm/0.1° or better. Simulated changes were correctly identified by the RITG148+ routines within approximately 0.2 mm/0.2° with the exception of the Field Centervs. Jaw Setting routine, which was found to have limited accuracy in cases where field centers were not aligned for all jaw settings due to inaccurate autorotation of the film during analysis. The performance of the RITG148+ software package was found to be acceptable for introduction into our clinical environment as an automated alternative to traditional analysis techniques for routine TomoTherapy quality assurance testing.
A Novel Quantitative Approach to Concept Analysis: The Internomological Network
Cook, Paul F.; Larsen, Kai R.; Sakraida, Teresa J.; Pedro, Leli
2012-01-01
Background When a construct such as patients’ transition to self-management of chronic illness is studied by researchers across multiple disciplines, the meaning of key terms can become confused. This results from inherent problems in language where a term can have multiple meanings (polysemy) and different words can mean the same thing (synonymy). Objectives To test a novel quantitative method for clarifying the meaning of constructs by examining the similarity of published contexts in which they are used. Method Published terms related to the concept transition to self-management of chronic illness were analyzed using the internomological network (INN), a type of latent semantic analysis to calculate the mathematical relationships between constructs based on the contexts in which researchers use each term. This novel approach was tested by comparing results to those from concept analysis, a best-practice qualitative approach to clarifying meanings of terms. By comparing results of the two methods, the best synonyms of transition to self-management, as well as key antecedent, attribute, and consequence terms, were identified. Results Results from INN analysis were consistent with those from concept analysis. The potential synonyms self-management, transition, and adaptation had the greatest utility. Adaptation was the clearest overall synonym, but had lower cross-disciplinary use. The terms coping and readiness had more circumscribed meanings. The INN analysis confirmed key features of transition to self-management, and suggested related concepts not found by the previous review. Discussion The INN analysis is a promising novel methodology that allows researchers to quantify the semantic relationships between constructs. The method works across disciplinary boundaries, and may help to integrate the diverse literature on self-management of chronic illness. PMID:22592387
Junkuy, Anongphan; Aramrattana, Apinun; Sribanditmongkol, Pongruk
2014-07-01
Three diagnostic methods have dominated drug-abuse research: self-report, urinalysis and hair analysis. Previous studies have compared detection rates for various drugs, but none has focused a three-pronged concordance study on the use of methamphetamine (MA). To determine and compare the rates of MA detection in urine and hair of subjects who reported consuming MA in the form of Yaba. Self-reports of Yaba use, as well as biological specimens for chemical analyses, were collected from paid volunteers participating in a larger project studying risk-taking behavior of young adults in northern Thailand. All subjects in the present study reported using Yaba within 90 days of enrollment. Hair analysis for MA followed a validated protocol that coupled solid phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS). Preliminary urinalysis was by means of REMEDi-HS. Positive urine was confirmed for MA by the SPME/GC-MS protocol. The MA detection rate by hair analysis (34.3%, n = 172) was significantly higher than by urinalysis (19.1%, n = 96) (p < 0.01; McNemar's test). All subjects with MA-positive urine samples reported using Yaba within 30 days of testing, while hair analysis gave positive results for self-reports up to 90 days. Urinalysis showed greater concordance with self-report than hair analysis if testing occurred within seven days of most recent admitted Yaba use. The reverse was true after 14 days. Agreement of laboratory findings with self-reports increased if test results for the two biological matrices were combined. There was no strong agreement between hair analysis and urinalysis for subjects reporting most recent use within 30 days of testing (kappa = 0.131; 95% CI = 0.022-0.240). For the Yaba users in the present study, urinalysis for MA significantly detected more positives than hair analysis if the most recent use reportedly occurred within seven days of testing. Hair analysis yielded better results after an interval of 14 days, with its window of detection extending up to three months. There were no urine positive samples for reported use after 30 days. Combining urinalysis and hair analysis increased the probability of detecting recent MA use. Both urinalysis and hair analysis significantly under-detected MA in the biological samples collected. The combined detection rate was 44.4%. This discrepancy might have resulted from over-reporting of Yaba use due to social/psychological factors and/or insufficient MA consumption causing test results to fall below cutoff levels.
Scotch, Matthew; Parmanto, Bambang; Monaco, Valerie
2008-01-01
Background Data analysis in community health assessment (CHA) involves the collection, integration, and analysis of large numerical and spatial data sets in order to identify health priorities. Geographic Information Systems (GIS) enable for management and analysis using spatial data, but have limitations in performing analysis of numerical data because of its traditional database architecture. On-Line Analytical Processing (OLAP) is a multidimensional datawarehouse designed to facilitate querying of large numerical data. Coupling the spatial capabilities of GIS with the numerical analysis of OLAP, might enhance CHA data analysis. OLAP-GIS systems have been developed by university researchers and corporations, yet their potential for CHA data analysis is not well understood. To evaluate the potential of an OLAP-GIS decision support system for CHA problem solving, we compared OLAP-GIS to the standard information technology (IT) currently used by many public health professionals. Methods SOVAT, an OLAP-GIS decision support system developed at the University of Pittsburgh, was compared against current IT for data analysis for CHA. For this study, current IT was considered the combined use of SPSS and GIS ("SPSS-GIS"). Graduate students, researchers, and faculty in the health sciences at the University of Pittsburgh were recruited. Each round consisted of: an instructional video of the system being evaluated, two practice tasks, five assessment tasks, and one post-study questionnaire. Objective and subjective measurement included: task completion time, success in answering the tasks, and system satisfaction. Results Thirteen individuals participated. Inferential statistics were analyzed using linear mixed model analysis. SOVAT was statistically significant (α = .01) from SPSS-GIS for satisfaction and time (p < .002). Descriptive results indicated that participants had greater success in answering the tasks when using SOVAT as compared to SPSS-GIS. Conclusion Using SOVAT, tasks were completed more efficiently, with a higher rate of success, and with greater satisfaction, than the combined use of SPSS and GIS. The results from this study indicate a potential for OLAP-GIS decision support systems as a valuable tool for CHA data analysis. PMID:18541037
Digital repeat analysis; setup and operation.
Nol, J; Isouard, G; Mirecki, J
2006-06-01
Since the emergence of digital imaging, there have been questions about the necessity of continuing reject analysis programs in imaging departments to evaluate performance and quality. As a marketing strategy, most suppliers of digital technology focus on the supremacy of the technology and its ability to reduce the number of repeats, resulting in less radiation doses given to patients and increased productivity in the department. On the other hand, quality assurance radiographers and radiologists believe that repeats are mainly related to positioning skills, and repeat analysis is the main tool to plan training needs to up-skill radiographers. A comparative study between conventional and digital imaging was undertaken to compare outcomes and evaluate the need for reject analysis. However, digital technology still being at its early development stages, setting a credible reject analysis program became the major task of the study. It took the department, with the help of the suppliers of the computed radiography reader and the picture archiving and communication system, over 2 years of software enhancement to build a reliable digital repeat analysis system. The results were supportive of both philosophies; the number of repeats as a result of exposure factors was reduced dramatically; however, the percentage of repeats as a result of positioning skills was slightly on the increase for the simple reason that some rejects in the conventional system qualifying for both exposure and positioning errors were classified as exposure error. The ability of digitally adjusting dark or light images reclassified some of those images as positioning errors.
Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.
1994-01-01
A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645
Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less
Applications of satellite image processing to the analysis of Amazonian cultural ecology
NASA Technical Reports Server (NTRS)
Behrens, Clifford A.
1991-01-01
This paper examines the application of satellite image processing towards identifying and comparing resource exploitation among indigenous Amazonian peoples. The use of statistical and heuristic procedures for developing land cover/land use classifications from Thematic Mapper satellite imagery will be discussed along with actual results from studies of relatively small (100 - 200 people) settlements. Preliminary research indicates that analysis of satellite imagery holds great potential for measuring agricultural intensification, comparing rates of tropical deforestation, and detecting changes in resource utilization patterns over time.
A Comparative Analysis of Higher Education Ranking Systems in Europe
ERIC Educational Resources Information Center
Hendel, Darwin D.; Stolz, Ingo
2008-01-01
According to Altbach in 2004, "everyone wants a world-class university". Corresponding developmental efforts undertaken by higher education institutions are very often referenced to improvements in ranking results. Surprisingly, there is relatively little analysis of variations in higher education ranking systems across countries…
SHRP2 EconWorks : wider economic benefits analysis tools : final report.
DOT National Transportation Integrated Search
2016-01-01
CDM Smith has completed an evaluation of the EconWorks Wider Economic Benefits (W.E.B.) : Analysis Tools for Connecticut Department of Transportation (CTDOT). The intent of this : evaluation was to compare the results of the outputs of this toolkit t...
Meta-analysis for explaining the variance in public transport demand elasticities in Europe
DOT National Transportation Integrated Search
1998-01-01
Results from past studies on transport demand elasticities show a large variance. This paper assesses key factors that influence the sensitivity of public transport users to transport costs in Europe, by carrying out a comparative analysis of the dif...
[A cost-effectiveness analysis on universal infant rotavirus vaccination strategy in China].
Sun, S L; Gao, Y Q; Yin, J; Zhuang, G H
2016-02-01
To evaluate the cost-effectiveness of current universal infant rotavirus vaccination strategy, in China. Through constructing decision tree-Markov model, we simulated rotavirus diarrhea associated cost and health outcome on those newborns in 2012 regarding different vaccination programs as: group with no vaccination, Rotavirus vaccination group and Rotateq vaccination group, respectively. We determined the optimal program, based on the comparison between incremental cost-effectiveness ratio (ICER) and China' s 2012 per capital gross domestic product (GDP). Compared with non-vaccination group, the Rotavirus vaccination and Rotateq vaccination groups had to pay 3 760 Yuan and 7 578 Yuan (both less than 2012 GDP per capital) to avert one disability adjusted life years (DALY) loss, respectively. RESULTS from sensitivity analysis indicated that both results were robust. Compared with Rotavirus vaccination program, the Rotateq vaccination program had to pay extra 81 068 Yuan (between 1 and 3 times GDP per capital) to avert one DALY loss. Data from the sensitivity analysis indicated that the result was not robust. From the perspective of health economics, both two-dose Rotarix vaccine and three-dose' s Rotateq vaccine programs were highly cost-effective, when compared to the non-vaccination program. It was appropriate to integrate rotavirus vaccine into the routine immunization program. Considering the large amount of extra cost that had to spend on Rotateq vaccination program, results from the sensitivity analysis showed that it was not robust. Rotateq vaccine required one more dose than the Rotarix vaccine, to be effective. However, it appeared more difficult to practice, suggesting that it was better to choose the Rotarix vaccine, at current stage.
NASA Astrophysics Data System (ADS)
Chen, Zhe; Parker, B. J.; Feng, D. D.; Fulton, R.
2004-10-01
In this paper, we compare various temporal analysis schemes applied to dynamic PET for improved quantification, image quality and temporal compression purposes. We compare an optimal sampling schedule (OSS) design, principal component analysis (PCA) applied in the image domain, and principal component analysis applied in the sinogram domain; for region-of-interest quantification, sinogram-domain PCA is combined with the Huesman algorithm to quantify from the sinograms directly without requiring reconstruction of all PCA channels. Using a simulated phantom FDG brain study and three clinical studies, we evaluate the fidelity of the compressed data for estimation of local cerebral metabolic rate of glucose by a four-compartment model. Our results show that using a noise-normalized PCA in the sinogram domain gives similar compression ratio and quantitative accuracy to OSS, but with substantially better precision. These results indicate that sinogram-domain PCA for dynamic PET can be a useful preprocessing stage for PET compression and quantification applications.
The solution of linear systems of equations with a structural analysis code on the NAS CRAY-2
NASA Technical Reports Server (NTRS)
Poole, Eugene L.; Overman, Andrea L.
1988-01-01
Two methods for solving linear systems of equations on the NAS Cray-2 are described. One is a direct method; the other is an iterative method. Both methods exploit the architecture of the Cray-2, particularly the vectorization, and are aimed at structural analysis applications. To demonstrate and evaluate the methods, they were installed in a finite element structural analysis code denoted the Computational Structural Mechanics (CSM) Testbed. A description of the techniques used to integrate the two solvers into the Testbed is given. Storage schemes, memory requirements, operation counts, and reformatting procedures are discussed. Finally, results from the new methods are compared with results from the initial Testbed sparse Choleski equation solver for three structural analysis problems. The new direct solvers described achieve the highest computational rates of the methods compared. The new iterative methods are not able to achieve as high computation rates as the vectorized direct solvers but are best for well conditioned problems which require fewer iterations to converge to the solution.
McAlearney, Ann Scheck; Walker, Daniel; Moss, Alexandra D; Bickell, Nina A
2016-04-01
Qualitative comparative analysis (QCA) is a methodology created to address causal complexity in social sciences research by preserving the objectivity of quantitative data analysis without losing detail inherent in qualitative research. However, its use in health services research (HSR) is limited, and questions remain about its application in this context. To explore the strengths and weaknesses of using QCA for HSR. Using data from semistructured interviews conducted as part of a multiple case study about adjuvant treatment underuse among underserved breast cancer patients, findings were compared using qualitative approaches with and without QCA to identify strengths, challenges, and opportunities presented by QCA. Ninety administrative and clinical key informants interviewed across 10 NYC area safety net hospitals. Transcribed interviews were coded by 3 investigators using an iterative and interactive approach. Codes were calibrated for QCA, as well as examined using qualitative analysis without QCA. Relative to traditional qualitative analysis, QCA strengths include: (1) addressing causal complexity, (2) results presentation as pathways as opposed to a list, (3) identification of necessary conditions, (4) the option of fuzzy-set calibrations, and (5) QCA-specific parameters of fit that allow researchers to compare outcome pathways. Weaknesses include: (1) few guidelines and examples exist for calibrating interview data, (2) not designed to create predictive models, and (3) unidirectionality. Through its presentation of results as pathways, QCA can highlight factors most important for production of an outcome. This strength can yield unique benefits for HSR not available through other methods.
Ziemann, Alexandra; Fouillet, Anne; Brand, Helmut; Krafft, Thomas
2016-01-01
Introduction Syndromic surveillance aims at augmenting traditional public health surveillance with timely information. To gain a head start, it mainly analyses existing data such as from web searches or patient records. Despite the setup of many syndromic surveillance systems, there is still much doubt about the benefit of the approach. There are diverse interactions between performance indicators such as timeliness and various system characteristics. This makes the performance assessment of syndromic surveillance systems a complex endeavour. We assessed if the comparison of several syndromic surveillance systems through Qualitative Comparative Analysis helps to evaluate performance and identify key success factors. Materials and Methods We compiled case-based, mixed data on performance and characteristics of 19 syndromic surveillance systems in Europe from scientific and grey literature and from site visits. We identified success factors by applying crisp-set Qualitative Comparative Analysis. We focused on two main areas of syndromic surveillance application: seasonal influenza surveillance and situational awareness during different types of potentially health threatening events. Results We found that syndromic surveillance systems might detect the onset or peak of seasonal influenza earlier if they analyse non-clinical data sources. Timely situational awareness during different types of events is supported by an automated syndromic surveillance system capable of analysing multiple syndromes. To our surprise, the analysis of multiple data sources was no key success factor for situational awareness. Conclusions We suggest to consider these key success factors when designing or further developing syndromic surveillance systems. Qualitative Comparative Analysis helped interpreting complex, mixed data on small-N cases and resulted in concrete and practically relevant findings. PMID:27182731
Comparison of analysis and experiment for dynamics of low-contact-ratio spur gears
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Rebbechi, Brian; Zakrajsek, James J.; Townsend, Dennis P.; Lin, Hsiang Hsi
1991-01-01
Low-contact-ratio spur gears were tested in NASA gear-noise-rig to study gear dynamics including dynamic load, tooth bending stress, vibration, and noise. The experimental results were compared with a NASA gear dynamics code to validate the code as a design tool for predicting transmission vibration and noise. Analytical predictions and experimental data for gear-tooth dynamic loads and tooth-root bending stress were compared at 28 operating conditions. Strain gage data were used to compute the normal load between meshing teeth and the bending stress at the tooth root for direct comparison with the analysis. The computed and measured waveforms for dynamic load and stress were compared for several test conditions. These are very similar in shape, which means the analysis successfully simulates the physical behavior of the test gears. The predicted peak value of the dynamic load agrees with the measurement results within an average error of 4.9 percent except at low-torque, high-speed conditions. Predictions of peak dynamic root stress are generally within 10 to 15 percent of the measured values.
(16) {C}16C-elastic scattering examined using several models at different energies
NASA Astrophysics Data System (ADS)
El-hammamy, M. N.; Attia, A.
2018-05-01
In the present paper, the first results concerning the theoretical analysis of the ^{16}C + p reaction by investigating two elastic scattering angular distributions measured at high energy compared to low energy for this system are reported. Several models for the real part of the nuclear potential are tested within the optical model formalism. The imaginary potential has a Woods-Saxon shape with three free parameters. Two types of density distribution and three different cluster structures for ^{16}C are assumed in the analysis. The results are compared with each other as well as with the experimental data to give evidence of the importance of these studied items.
Hatz, F; Hardmeier, M; Bousleiman, H; Rüegg, S; Schindler, C; Fuhr, P
2015-02-01
To compare the reliability of a newly developed Matlab® toolbox for the fully automated, pre- and post-processing of resting state EEG (automated analysis, AA) with the reliability of analysis involving visually controlled pre- and post-processing (VA). 34 healthy volunteers (age: median 38.2 (20-49), 82% female) had three consecutive 256-channel resting-state EEG at one year intervals. Results of frequency analysis of AA and VA were compared with Pearson correlation coefficients, and reliability over time was assessed with intraclass correlation coefficients (ICC). Mean correlation coefficient between AA and VA was 0.94±0.07, mean ICC for AA 0.83±0.05 and for VA 0.84±0.07. AA and VA yield very similar results for spectral EEG analysis and are equally reliable. AA is less time-consuming, completely standardized, and independent of raters and their training. Automated processing of EEG facilitates workflow in quantitative EEG analysis. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Validation of numerical models for flow simulation in labyrinth seals
NASA Astrophysics Data System (ADS)
Frączek, D.; Wróblewski, W.
2016-10-01
CFD results were compared with the results of experiments for the flow through the labyrinth seal. RANS turbulence models (k-epsilon, k-omega, SST and SST-SAS) were selected for the study. Steady and transient results were analyzed. ANSYS CFX was used for numerical computation. The analysis included flow through sealing section with the honeycomb land. Leakage flows and velocity profiles in the seal were compared. In addition to the comparison of computational models, the divergence of modeling and experimental results has been determined. Tips for modeling these problems were formulated.
Quality factor analysis for aberrated laser beam
NASA Astrophysics Data System (ADS)
Ghafary, B.; Alavynejad, M.; Kashani, F. D.
2006-12-01
The quality factor of laser beams has attracted considerable attention and some different approaches have been reported to treat the problem. In this paper we analyze quality factor of laser beam and compare the effect of different aberrations on beam quality by expanding pure phase term of wavefront in terms of Zernike polynomials. Also we analyze experimentally the change of beam quality for different Astigmatism aberrations, and compare theoretical results with experimentally results. The experimental and theoretical results are in good agreement.
Cost analysis of long-term outcomes of an urban mental health court.
Kubiak, Sheryl; Roddy, Juliette; Comartin, Erin; Tillander, Elizabeth
2015-10-01
Multiple studies have demonstrated decreased recidivism and increased treatment engagement for individuals with serious mental illness involved in Mental Health Courts (MHC). However, the limited availability of social and fiscal resources requires an analysis of the relationship between a program's effectiveness and its costs. Outcome costs associated with a sample of 105 participants discharged for more than 1 year - and grouped by completion status - were compared to an eligible sample not enrolled (n=45). Transactional costs analysis (TCA) was used to calculate outcomes associated with treatment, arrest, and confinement in the 12-month post-MHC. Total outcome costs for the Successful Group ($16,964) significantly differed from the Unsuccessful ($32,258) and Compare Groups ($39,870). Costs associated with the higher number of arrests for those in the Compare Group created the largest differences. Total cost savings between Successful and Compare (M=$22,906) equated to $916,240 and savings between Unsuccessful and Compare (M=$7612) were $494,708. The total combined cost savings for participants in the 12-month post-MHC period was $1,411,020. While it is important to understand that MHCs and the individuals that they serve vary and these results are for a felony-level court, policy makers and researchers can use these results to guide their decision-making. Copyright © 2015 Elsevier Ltd. All rights reserved.
Saldívar-Uribe, Christina; de la Portilla-Villanueva, Mario Alberto; Esau-Mendoza-García, Alberto
2017-01-01
The aim was to compare active disease in patients diagnosed with multiple sclerosis, brain by MRI after gadolinium application at one minute and 20 minutes. A longitudinal, prospective, observational, analytical and comparative study was conducted in 18 patients over 18 years of age diagnosed with multiple sclerosis (MS). An analysis was made for each patient, watching for inflammatory activity in MS lesions, comparing the results to one minute and 20 minutes after the application of gadolinium. For the descriptive analysis, absolute frequencies and percentages were used, as well as means and standard deviations or medians with ranges for the inferential analysis comparing the presence or absence of enhancement in lesions at one minute and 20 minutes; the exact probability test used was Fisher. Finally, the results were analyzed, looking at the gender distribution: 14 (77.8%) were female. The average age was 36.2 ± 9.5 years, with a minimum age of 18 years and a maximum of 55 years; four patients (22.2%) presented further highlight active lesions at 20 minutes, and two patients (11.1%) presented enhancement at one minute. Concluding that MRI in the diagnosis of MS is very important for the detection of activity in lesions caused by the disease, it is evident that the optimum time for evaluation of postcontrast sequences is 20 minutes.
Rütten, A; Ziemainz, H; Schena, F; Stahl, T; Stiggelbout, M; Auweele, Y Vanden; Vuillemin, A; Welshman, J
2003-06-01
The European Physical Activity Surveillance System (EUPASS) research project compared several physical activity (PA) measures (including the International Physical Activity Questionnaire (IPAQ)) in a time series survey in eight countries of the European Union. The present paper describes first results provided by the different instruments regarding PA participation, frequency and duration, both at the European and national levels. The purpose of the present study is to explore and compare the specific quality and usefulness of different indicators rather than to provide valid and reliable prevalence data. Thus, the main focus is on discussion of the methodological implications of the results presented. A time series survey based on computer-aided telephone interviewing (CATI) was carried out in eight European countries over a six-month period. The study provided for about 100 realised interviews per month in each country (i.e. approximately 600 per country). Descriptive statistical analysis was used to: (1) report IPAQ results on vigorous, moderate and light PA and sitting, as well as on the overall measure of calories expenditure (MET min-1), in the different countries; (2) compare these results with national PA indicators tested in EUPASS; and (3) compare IPAQ results with other European studies. First, the scores for the different PA categories as well as for the overall measure of calories expenditure provided by the IPAQ appeared rather high compared with previous studies and public health recommendations. Second, the different PA measurements used in EUPASS provided completely different results. For example, national indicators used in Germany and The Netherlands to date neither corresponded in absolute values (e.g. means of PA or sitting) nor correlated with the IPAQ in any significant way. Third, comparing EU countries, the ranking for vigorous, moderate and light activities by use of the IPAQ differed from that of other European studies. For example, in the present analysis, German respondents generally showed higher scores for PA than the Finns and the Dutch, while, in contrast, findings from other studies ranked Finland before The Netherlands and Germany. The present analysis highlights some methodological implications of the IPAQ instrument. Among other things, differences in overall scores for PA as well as in the ranking of nations between the present results using IPAQ and other measures and studies may partly be due to the concepts of PA behind the measurements. Further analysis should investigate if the range of PA-related categories provided by the IPAQ is fully appropriate to measure all relevant daily activities; it may also consider the public health implications of mixing up different contexts of PA (e.g. work, leisure-time, transportation) in the IPAQ short version.
Comparative analysis and visualization of multiple collinear genomes
2012-01-01
Background Genome browsers are a common tool used by biologists to visualize genomic features including genes, polymorphisms, and many others. However, existing genome browsers and visualization tools are not well-suited to perform meaningful comparative analysis among a large number of genomes. With the increasing quantity and availability of genomic data, there is an increased burden to provide useful visualization and analysis tools for comparison of multiple collinear genomes such as the large panels of model organisms which are the basis for much of the current genetic research. Results We have developed a novel web-based tool for visualizing and analyzing multiple collinear genomes. Our tool illustrates genome-sequence similarity through a mosaic of intervals representing local phylogeny, subspecific origin, and haplotype identity. Comparative analysis is facilitated through reordering and clustering of tracks, which can vary throughout the genome. In addition, we provide local phylogenetic trees as an alternate visualization to assess local variations. Conclusions Unlike previous genome browsers and viewers, ours allows for simultaneous and comparative analysis. Our browser provides intuitive selection and interactive navigation about features of interest. Dynamic visualizations adjust to scale and data content making analysis at variable resolutions and of multiple data sets more informative. We demonstrate our genome browser for an extensive set of genomic data sets composed of almost 200 distinct mouse laboratory strains. PMID:22536897
NASA Technical Reports Server (NTRS)
Schmeckpeper, K. R.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA first completed an analysis of the Electrical Power Distribution and Control (EPD and C) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter EPD and C hardware. Volume 2 continues the presentation of IOA worksheets.
NASA Astrophysics Data System (ADS)
Carvalho, F. S.; Braga, J. P.
2018-05-01
We have investigated the more stable structures for small gold clusters, Aun (2≤ n ≤ 6), using the density functional theory method. Two functionals used in the literature, the well-known B3LYP and M06-L, were compared with the one that has not been used for this system yet, M08-SO, and the results for dimer were compared with experimental data. It was found that M08-SO gives the best results for the effective core potential and basis set tested. Therefore, the functional M08-SO was used for other structures. The planar geometries were found to have the lowest energies. After the geometry optimization, Mulliken populational analysis (MPA) and natural populational analysis (NPA) were carried out and the results for charge distribution in gold trimer and tetramer were compared with data found in literature. The MPA calculation does not give results in agreement with the literature. On the other hand, the NPA calculation gives coherent data. The results showed that the charge distribution will not always predict the more favorable site of interaction.
A matching framework to improve causal inference in interrupted time-series analysis.
Linden, Ariel
2018-04-01
Interrupted time-series analysis (ITSA) is a popular evaluation methodology in which a single treatment unit's outcome is studied over time and the intervention is expected to "interrupt" the level and/or trend of the outcome, subsequent to its introduction. When ITSA is implemented without a comparison group, the internal validity may be quite poor. Therefore, adding a comparable control group to serve as the counterfactual is always preferred. This paper introduces a novel matching framework, ITSAMATCH, to create a comparable control group by matching directly on covariates and then use these matches in the outcomes model. We evaluate the effect of California's Proposition 99 (passed in 1988) for reducing cigarette sales, by comparing California to other states not exposed to smoking reduction initiatives. We compare ITSAMATCH results to 2 commonly used matching approaches, synthetic controls (SYNTH), and regression adjustment; SYNTH reweights nontreated units to make them comparable to the treated unit, and regression adjusts covariates directly. Methods are compared by assessing covariate balance and treatment effects. Both ITSAMATCH and SYNTH achieved covariate balance and estimated similar treatment effects. The regression model found no treatment effect and produced inconsistent covariate adjustment. While the matching framework achieved results comparable to SYNTH, it has the advantage of being technically less complicated, while producing statistical estimates that are straightforward to interpret. Conversely, regression adjustment may "adjust away" a treatment effect. Given its advantages, ITSAMATCH should be considered as a primary approach for evaluating treatment effects in multiple-group time-series analysis. © 2017 John Wiley & Sons, Ltd.
Quantified Uncertainties in Comparative Life Cycle Assessment: What Can Be Concluded?
2018-01-01
Interpretation of comparative Life Cycle Assessment (LCA) results can be challenging in the presence of uncertainty. To aid in interpreting such results under the goal of any comparative LCA, we aim to provide guidance to practitioners by gaining insights into uncertainty-statistics methods (USMs). We review five USMs—discernibility analysis, impact category relevance, overlap area of probability distributions, null hypothesis significance testing (NHST), and modified NHST–and provide a common notation, terminology, and calculation platform. We further cross-compare all USMs by applying them to a case study on electric cars. USMs belong to a confirmatory or an exploratory statistics’ branch, each serving different purposes to practitioners. Results highlight that common uncertainties and the magnitude of differences per impact are key in offering reliable insights. Common uncertainties are particularly important as disregarding them can lead to incorrect recommendations. On the basis of these considerations, we recommend the modified NHST as a confirmatory USM. We also recommend discernibility analysis as an exploratory USM along with recommendations for its improvement, as it disregards the magnitude of the differences. While further research is necessary to support our conclusions, the results and supporting material provided can help LCA practitioners in delivering a more robust basis for decision-making. PMID:29406730
Kloefkorn, Heidi E.; Pettengill, Travis R.; Turner, Sara M. F.; Streeter, Kristi A.; Gonzalez-Rothi, Elisa J.; Fuller, David D.; Allen, Kyle D.
2016-01-01
While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns. PMID:27554674
Kloefkorn, Heidi E; Pettengill, Travis R; Turner, Sara M F; Streeter, Kristi A; Gonzalez-Rothi, Elisa J; Fuller, David D; Allen, Kyle D
2017-03-01
While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns.
Influence of plasma shock wave on the morphology of laser drilling in different environments
NASA Astrophysics Data System (ADS)
Zhai, Zhaoyang; Wang, Wenjun; Mei, Xuesong; Wang, Kedian; Yang, Huizhu
2017-05-01
Nanosecond pulse laser was used to study nickel-based alloy drilling and compare processing results of microholes in air environment and water environment. Through analysis and comparison, it's found that environmental medium had obvious influence on morphology of laser drilling. High-speed camera was used to shoot plasma morphology during laser drilling process, theoretical formula was used to calculate boundary dimension of plasma and shock wave velocity, and finally parameters were substituted into computational fluid dynamics simulation software to obtain solutions. Obtained analysis results could intuitively explain different morphological features and forming reasons between laser drilling in air environment and water environment in the experiment from angle of plasma shock waves. By comparing simulation results and experimental results, it could help to get an understanding of formation mechanism of microhole morphology, thus providing basis for further improving process optimization of laser drilling quality.
Gianfrilli, P; Pantosti, A; Luzzi, I
1985-01-01
Direct gas-liquid chromatography of faecal specimens with isocaproic acid as a marker was used for the rapid diagnosis of Clostridium difficile associated diarrhoeal diseases. Ninety stools were examined and results were compared with conventional culture on selective medium and cytotoxin assay in tissue culture. Using a combined analysis of isocaproic acid and butyric acid peak heights we defined three categories: positive, negative, and indeterminate. When the indeterminate group was excluded, the positive and negative predictive values of gas-liquid chromatography analysis were 86.9% and 85% respectively compared with culture and 71.4% and 95% respectively compared with cytotoxin assay. PMID:4008667
[Mirtazapine versus other antidepressive agents for depression].
Knud Larsen, Jens
2012-11-12
A Cochrane analysis compared efficacy and side effects of mirtazapine with other antidepressants. After six weeks of treatment no reliable difference of efficacy between mirtazapine, selective serotonin reuptake inhibitors (SSRI), noradrenaline reuptake inhibitors or tricyclic antidepressants was found. The side effects like increased sleep and weight gain were compared by treatment with mirtazapine and treatment with SSRI antidepressants. The very fact of the sleep effect and the fast onset of action have probably increased the effect size compared with SSRI antidepressants. The results of the Cochrane analysis cannot for certain be generalized to inpatients, as other studies have found tricyclic antidepressants to be especially effective.
Education Policy Outlook: Denmark
ERIC Educational Resources Information Center
Pont, Beatriz; Figueroa, Diana Toledo; Albiser, Etienne; Yee, Hyo Jeong; Skalde, Annette; Zapata, Juliana; Fraccola, Sylvain
2014-01-01
This policy profile on education in Denmark is part of the new Education Policy Outlook series, which will present comparative analysis of education policies and reforms across OECD countries. Building on the substantial comparative and sectorial policy knowledge base available within the OECD, the series will result in a biennial publication…
Social Networks and Mourning: A Comparative Approach.
ERIC Educational Resources Information Center
Rubin, Nissan
1990-01-01
Suggests using social network theory to explain varieties of mourning behavior in different societies. Compares participation in funeral ceremonies of members of different social circles in American society and Israeli kibbutz. Concludes that results demonstrated validity of concepts deriving from social network analysis in study of bereavement,…
Rubin, Robert J; Glaspy, John A; Adams, John L; Mafilios, Michael S; Wang, Sharon M; Viswanathan, Hema N; Kallich, Joel D
2008-01-01
This analysis was conducted to compare the direct medical costs of treatment with darbepoetin alfa every 3 weeks (Q3W) and epoetin alfa every week (QW) in patients with chemotherapy-induced anaemia (CIA) from the payer's perspective. An analysis was conducted from a US health plan perspective to compare the annual budget impact for CIA with darbepoetin alfa Q3W and epoetin alfa QW over a 16-week treatment period. Dosing regimens were obtained from registration clinical trials. Mean doses, including dose adjustments, were 375.6 microg Q3W for darbepoetin alfa and 43,187 U QW for epoetin alfa. Costs of medical resources included drug acquisition and administration costs. The base case analysis resulted in a per-patient budget impact of $8,544 and $8,667 for darbepoetin alfa and epoetin alfa, respectively. Per member per month cost was $0.90 for darbepoetin alfa and $0.91 for epoetin alfa, based on an estimate of 2,735 CIA patients in a health plan population of 2.17 million. The analysis was most sensitive to drug dose, treatment period and drug price. Results suggest that per-patient direct medical costs of CIA treatment, when initiated at labelled starting doses, are comparable for darbepoetin alfa Q3W and epoetin alfa QW.
NASA Astrophysics Data System (ADS)
Srinivas, Kadivendi; Vundavilli, Pandu R.; Manzoor Hussain, M.; Saiteja, M.
2016-09-01
Welding input parameters such as current, gas flow rate and torch angle play a significant role in determination of qualitative mechanical properties of weld joint. Traditionally, it is necessary to determine the weld input parameters for every new welded product to obtain a quality weld joint which is time consuming. In the present work, the effect of plasma arc welding parameters on mild steel was studied using a neural network approach. To obtain a response equation that governs the input-output relationships, conventional regression analysis was also performed. The experimental data was constructed based on Taguchi design and the training data required for neural networks were randomly generated, by varying the input variables within their respective ranges. The responses were calculated for each combination of input variables by using the response equations obtained through the conventional regression analysis. The performances in Levenberg-Marquardt back propagation neural network and radial basis neural network (RBNN) were compared on various randomly generated test cases, which are different from the training cases. From the results, it is interesting to note that for the above said test cases RBNN analysis gave improved training results compared to that of feed forward back propagation neural network analysis. Also, RBNN analysis proved a pattern of increasing performance as the data points moved away from the initial input values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gill, M.; Vallada, H.; Collier, D.
1996-02-16
Several groups have reported weak evidence for linkage between schizophrenia and genetic markers located on chromosome 22q using the lod score method of analysis. However these findings involved different genetic markers and methods of analysis, and so were not directly comparable. To resolve this issue we have performed a combined analysis of genotypic data from the marker D22S278 in multiply affected schizophrenic families derived from 11 independent research groups worldwide. This marker was chosen because it showed maximum evidence for linkage in three independent datasets. Using the affected sib-pair method as implemented by the program ESPA, the combined dataset showedmore » 252 alleles shared compared with 188 alleles not shared (chi-square 9.31, 1df, P = 0.001) where parental genotype data was completely known. When sib-pairs for whom parental data was assigned according to probability were included the number of alleles shared was 514.1 compared with 437.8 not shared (chi-square 6.12, 1df, P = 0.006). Similar results were obtained when a likelihood ratio method for sib-pair analysis was used. These results indicate that there may be a susceptibility locus for schizophrenia at 22q12. 27 refs., 3 tabs.« less
Type 2 diabetes mellitus: distribution of genetic markers in Kazakh population.
Sikhayeva, Nurgul; Talzhanov, Yerkebulan; Iskakova, Aisha; Dzharmukhanov, Jarkyn; Nugmanova, Raushan; Zholdybaeva, Elena; Ramanculov, Erlan
2018-01-01
Ethnic differences exist in the frequencies of genetic variations that contribute to the risk of common disease. This study aimed to analyse the distribution of several genes, previously associated with susceptibility to type 2 diabetes and obesity-related phenotypes, in a Kazakh population. A total of 966 individuals belonging to the Kazakh ethnicity were recruited from an outpatient clinic. We genotyped 41 common single nucleotide polymorphisms (SNPs) previously associated with type 2 diabetes in other ethnic groups and 31 of these were in Hardy-Weinberg equilibrium. The obtained allele frequencies were further compared to publicly available data from other ethnic populations. Allele frequencies for other (compared) populations were pooled from the haplotype map (HapMap) database. Principal component analysis (PCA), cluster analysis, and multidimensional scaling (MDS) were used for the analysis of genetic relationship between the populations. Comparative analysis of allele frequencies of the studied SNPs showed significant differentiation among the studied populations. The Kazakh population was grouped with Asian populations according to the cluster analysis and with the Caucasian populations according to PCA. According to MDS, results of the current study show that the Kazakh population holds an intermediate position between Caucasian and Asian populations. A high percentage of population differentiation was observed between Kazakh and world populations. The Kazakh population was clustered with Caucasian populations, and this result may indicate a significant Caucasian component in the Kazakh gene pool.
Comparing methods for analysis of biomedical hyperspectral image data
NASA Astrophysics Data System (ADS)
Leavesley, Silas J.; Sweat, Brenner; Abbott, Caitlyn; Favreau, Peter F.; Annamdevula, Naga S.; Rich, Thomas C.
2017-02-01
Over the past 2 decades, hyperspectral imaging technologies have been adapted to address the need for molecule-specific identification in the biomedical imaging field. Applications have ranged from single-cell microscopy to whole-animal in vivo imaging and from basic research to clinical systems. Enabling this growth has been the availability of faster, more effective hyperspectral filtering technologies and more sensitive detectors. Hence, the potential for growth of biomedical hyperspectral imaging is high, and many hyperspectral imaging options are already commercially available. However, despite the growth in hyperspectral technologies for biomedical imaging, little work has been done to aid users of hyperspectral imaging instruments in selecting appropriate analysis algorithms. Here, we present an approach for comparing the effectiveness of spectral analysis algorithms by combining experimental image data with a theoretical "what if" scenario. This approach allows us to quantify several key outcomes that characterize a hyperspectral imaging study: linearity of sensitivity, positive detection cut-off slope, dynamic range, and false positive events. We present results of using this approach for comparing the effectiveness of several common spectral analysis algorithms for detecting weak fluorescent protein emission in the midst of strong tissue autofluorescence. Results indicate that this approach should be applicable to a very wide range of applications, allowing a quantitative assessment of the effectiveness of the combined biology, hardware, and computational analysis for detecting a specific molecular signature.
NASA Astrophysics Data System (ADS)
Keyport, Ren N.; Oommen, Thomas; Martha, Tapas R.; Sajinkumar, K. S.; Gierke, John S.
2018-02-01
A comparative analysis of landslides detected by pixel-based and object-oriented analysis (OOA) methods was performed using very high-resolution (VHR) remotely sensed aerial images for the San Juan La Laguna, Guatemala, which witnessed widespread devastation during the 2005 Hurricane Stan. A 3-band orthophoto of 0.5 m spatial resolution together with a 115 field-based landslide inventory were used for the analysis. A binary reference was assigned with a zero value for landslide and unity for non-landslide pixels. The pixel-based analysis was performed using unsupervised classification, which resulted in 11 different trial classes. Detection of landslides using OOA includes 2-step K-means clustering to eliminate regions based on brightness; elimination of false positives using object properties such as rectangular fit, compactness, length/width ratio, mean difference of objects, and slope angle. Both overall accuracy and F-score for OOA methods outperformed pixel-based unsupervised classification methods in both landslide and non-landslide classes. The overall accuracy for OOA and pixel-based unsupervised classification was 96.5% and 94.3%, respectively, whereas the best F-score for landslide identification for OOA and pixel-based unsupervised methods: were 84.3% and 77.9%, respectively.Results indicate that the OOA is able to identify the majority of landslides with a few false positive when compared to pixel-based unsupervised classification.
Lee, Ingi; Agarwal, Rajender K.; Lee, Bruce Y.; Fishman, Neil O.; Umscheid, Craig A.
2013-01-01
Objective To compare use of chlorhexidine with use of iodine for preoperative skin antisepsis with respect to effectiveness in preventing surgical site infections (SSIs) and cost. Methods We searched the Agency for Healthcare Research and Quality website, the Cochrane Library, Medline, and EMBASE up to January 2010 for eligible studies. Included studies were systematic reviews, meta-analyses, or randomized controlled trials (RCTs) comparing preoperative skin antisepsis with chlorhexidine and with iodine and assessing for the outcomes of SSI or positive skin culture result after application. One reviewer extracted data and assessed individual study quality, quality of evidence for each outcome, and publication bias. Meta-analyses were performed using a fixed-effects model. Using results from the meta-analysis and cost data from the Hospital of the University of Pennsylvania, we developed a decision analytic cost-benefit model to compare the economic value, from the hospital perspective, of antisepsis with iodine versus antisepsis with 2 preparations of chlorhexidine (ie, 4% chlorhexidine bottle and single-use applicators of a 2% chlorhexidine gluconate [CHG] and 70% isopropyl alcohol [IPA] solution), and also performed sensitivity analyses. Results Nine RCTs with a total of 3,614 patients were included in the meta-analysis. Meta-analysis revealed that chlorhexidine antisepsis was associated with significantly fewer SSIs (adjusted risk ratio, 0.64 [95% confidence interval, [0.51–0.80]) and positive skin culture results (adjusted risk ratio, 0.44 [95% confidence interval, 0.35–0.56]) than was iodine antisepsis. In the cost-benefit model baseline scenario, switching from iodine to chlorhexidine resulted in a net cost savings of $16–$26 per surgical case and $349,904–$568,594 per year for the Hospital of the University of Pennsylvania. Sensitivity analyses showed that net cost savings persisted under most circumstances. Conclusions Preoperative skin antisepsis with chlorhexidine is more effective than preoperative skin antisepsis with iodine for preventing SSI and results in cost savings. PMID:20969449
Postbuckling and Growth of Delaminations in Composite Plates Subjected to Axial Compression
NASA Technical Reports Server (NTRS)
Reeder, James R.; Chunchu, Prasad B.; Song, Kyongchan; Ambur, Damodar R.
2002-01-01
The postbuckling response and growth of circular delaminations in flat and curved plates are investigated as part of a study to identify the criticality of delamination locations through the laminate thickness. The experimental results from tests on delaminated plates are compared with finite element analysis results generated using shell models. The analytical prediction of delamination growth is obtained by assessing the strain energy release rate results from the finite element model and comparing them to a mixed-mode fracture toughness failure criterion. The analytical results for onset of delamination growth compare well with experimental results generated using a 3-dimensional displacement visualization system. The record of delamination progression measured in this study has resulted in a fully 3-dimensional test case with which progressive failure models can be validated.
NASA Technical Reports Server (NTRS)
Doggett, R. V., Jr.; Cunningham, H. J.
1976-01-01
The Level 16 flutter analysis capability was applied to an aspect-ratio-6.8 subsonic transport type wing, an aspect-ratio-1.7 arrow wing, and an aspect-ratio-1.3 all movable horizontal tail with a geared elevator. The transport wing and arrow wing results are compared with experimental results obtained in the Langley transonic dynamic tunnel and with other calculated results obtained using subsonic lifting surface (kernel function) unsteady aerodynamic theory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakanishi, Hidetoshi, E-mail: nakanisi@screen.co.jp; Ito, Akira, E-mail: a.ito@screen.co.jp; Takayama, Kazuhisa, E-mail: takayama.k0123@gmail.com
2015-11-15
A laser terahertz emission microscope (LTEM) can be used for noncontact inspection to detect the waveforms of photoinduced terahertz emissions from material devices. In this study, we experimentally compared the performance of LTEM with conventional analysis methods, e.g., electroluminescence (EL), photoluminescence (PL), and laser beam induced current (LBIC), as an inspection method for solar cells. The results showed that LTEM was more sensitive to the characteristics of the depletion layer of the polycrystalline solar cell compared with EL, PL, and LBIC and that it could be used as a complementary tool to the conventional analysis methods for a solar cell.
NASA Technical Reports Server (NTRS)
Schredder, J. M.
1988-01-01
A comparative analysis was performed, using both the Geometrical Theory of Diffraction (GTD) and traditional pathlength error analysis techniques, for predicting RF antenna gain performance and pointing corrections. The NASA/JPL 70 meter antenna with its shaped surface was analyzed for gravity loading over the range of elevation angles. Also analyzed were the effects of lateral and axial displacements of the subreflector. Significant differences were noted between the predictions of the two methods, in the effect of subreflector displacements, and in the optimal subreflector positions to focus a gravity-deformed main reflector. The results are of relevance to future design procedure.
Chaotic behavior in Malaysian stock market: A study with recurrence quantification analysis
NASA Astrophysics Data System (ADS)
Niu, Betty Voon Wan; Noorani, Mohd Salmi Md; Jaaman, Saiful Hafizah
2016-11-01
The dynamics of stock market has been questioned for decades. Its behavior appeared random yet some found it behaves as chaos. Up to 5000 daily adjusted closing data of FTSE Bursa Malaysia Kuala Lumpur Composite Index (KLSE) was investigated through recurrence plot and recurrence quantification analysis. Results were compared between stochastic system, chaotic system and deterministic system. Results show that KLSE daily adjusted closing data behaves chaotically.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups
Bala, Madhu; Goyal, Virender
2014-01-01
ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005
NASA Astrophysics Data System (ADS)
Silitonga, Faber Y.; Agoes Moelyadi, M.
2018-04-01
The development of High Altitude Long Endurance (HALE) Unmanned Aerial Vehicle (UAV) has been emerged for both civil and military purposes. Its ability of operating in high altitude with long endurance is important in supporting maritime applications.Preliminary analysis of HALE UAV lift distribution of the wing presented to give decisive consideration for its early development. Ensuring that the generated lift is enough to compensate its own weight. Therotical approach using Pradtl’s non-linear lifting line theory will be compared with modern numerical approach using Computational Fluid Dynamics (CFD). Results of wing lift distribution calculated from both methods will be compared to study the reliability of it. HALE UAV ITB has high aspect ratio wing and will be analyze at cruise flight condition. The result indicates difference between Non-linear Lifting Line and CFD method.
Trautz, Florian; Dreßler, Jan; Stassart, Ruth; Müller, Wolf; Ondruschka, Benjamin
2018-01-03
Immunohistochemistry (IHC) has become an integral part in forensic histopathology over the last decades. However, the underlying methods for IHC vary greatly depending on the institution, creating a lack of comparability. The aim of this study was to assess the optimal approach for different technical aspects of IHC, in order to improve and standardize this procedure. Therefore, qualitative results from manual and automatic IHC staining of brain samples were compared, as well as potential differences in suitability of common IHC glass slides. Further, possibilities of image digitalization and connected issues were investigated. In our study, automatic staining showed more consistent staining results, compared to manual staining procedures. Digitalization and digital post-processing facilitated direct analysis and analysis for reproducibility considerably. No differences were found for different commercially available microscopic glass slides regarding suitability of IHC brain researches, but a certain rate of tissue loss should be expected during the staining process.
Analysis of energy recovery potential using innovative technologies of waste gasification.
Lombardi, Lidia; Carnevale, Ennio; Corti, Andrea
2012-04-01
In this paper, two alternative thermo-chemical processes for waste treatment were analysed: high temperature gasification and gasification associated to plasma process. The two processes were analysed from the thermodynamic point of view, trying to reconstruct two simplified models, using appropriate simulation tools and some support data from existing/planned plants, able to predict the energy recovery performances by process application. In order to carry out a comparative analysis, the same waste stream input was considered as input to the two models and the generated results were compared. The performances were compared with those that can be obtained from conventional combustion with energy recovery process by means of steam turbine cycle. Results are reported in terms of energy recovery performance indicators as overall energy efficiency, specific energy production per unit of mass of entering waste, primary energy source savings, specific carbon dioxide production. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
VanKeuls, Fred W.; Chevalier, Chris T.; Miranda, Felix A.; Carlson, C. M.; Rivkin, T. V.; Parilla, P. A.; Perkins, J. D.; Ginley, D. S.
2001-01-01
Experimental measurements of coplanar waveguide (CPW) circuits atop thin films of ferroelectric Ba(x)Sr(1-x)TiO3 (BST) were made as a function bias from 0 to 200 V and frequency from 0.045 to 20 GHz. The resulting phase shifts are compared with method of moments electromagnetic simulations and a conformal mapping analysis to determine the dielectric constant of the BST films. Based on the correlation between the experimental and the modeled data, an analysis of the extent to which the electromagnetic simulators provide reliable values for the dielectric constant of the ferroelectric in these structures has been performed. In addition, to determine how well the modeled data compare with experimental data, the dielectric constant values were also compared to low frequency measurements of interdigitated capacitor circuits on the same films. Results of these comparisons will be presented.
Gosper, E C; Raubenheimer, D; Machovsky-Capuska, G E; Chaves, A V
2016-01-01
To investigate if the label information and nutrient composition of commercial cat foods are accurate and compliant with the Australian Standard (AS 5812-2011) and if they meet the nutritional requirements of an adult cat. A chemical analysis of 10 wet and 10 dry commercial cat foods labelled as 'nutritionally complete' for the adult cat was performed. The results were compared with the package composition values, the Australian Standard and the unique dietary requirements of the cat. In addition, the results of the chemical analysis were compared with the nutrient requirements published by the Association of the American Feed Control Officials and the National Research Council. When compared with the Australian Standard, 9 of the 20 cat foods did not adhere to their 'guaranteed analysis' and 8 did not adhere to the standards for nutrient composition. Also, various deficiencies and excesses of crude protein, crude fat, fatty acid and amino acid were observed in the majority of the cat foods. The results of this study highlight a need for an improved method of ensuring that label information and nutrient composition are accurate and comply with the Australian Standard (AS 5812-2011) to ensure the adult cat's unique dietary requirements are being met by commercial adult cat food. © 2016 Australian Veterinary Association.
NASA Astrophysics Data System (ADS)
Vuye, Cedric; Vanlanduit, Steve; Guillaume, Patrick
2009-06-01
When using optical measurements of the sound fields inside a glass tube, near the material under test, to estimate the reflection and absorption coefficients, not only these acoustical parameters but also confidence intervals can be determined. The sound fields are visualized using a scanning laser Doppler vibrometer (SLDV). In this paper the influence of different test signals on the quality of the results, obtained with this technique, is examined. The amount of data gathered during one measurement scan makes a thorough statistical analysis possible leading to the knowledge of confidence intervals. The use of a multi-sine, constructed on the resonance frequencies of the test tube, shows to be a very good alternative for the traditional periodic chirp. This signal offers the ability to obtain data for multiple frequencies in one measurement, without the danger of a low signal-to-noise ratio. The variability analysis in this paper clearly shows the advantages of the proposed multi-sine compared to the periodic chirp. The measurement procedure and the statistical analysis are validated by measuring the reflection ratio at a closed end and comparing the results with the theoretical value. Results of the testing of two building materials (an acoustic ceiling tile and linoleum) are presented and compared to supplier data.
Probabilistic Analysis for Comparing Fatigue Data Based on Johnson-Weibull Parameters
NASA Technical Reports Server (NTRS)
Hendricks, Robert C.; Zaretsky, Erwin V.; Vicek, Brian L.
2007-01-01
Probabilistic failure analysis is essential when analysis of stress-life (S-N) curves is inconclusive in determining the relative ranking of two or more materials. In 1964, L. Johnson published a methodology for establishing the confidence that two populations of data are different. Simplified algebraic equations for confidence numbers were derived based on the original work of L. Johnson. Using the ratios of mean life, the resultant values of confidence numbers deviated less than one percent from those of Johnson. It is possible to rank the fatigue lives of different materials with a reasonable degree of statistical certainty based on combined confidence numbers. These equations were applied to rotating beam fatigue tests that were conducted on three aluminum alloys at three stress levels each. These alloys were AL 2024, AL 6061, and AL 7075. The results were analyzed and compared using ASTM Standard E739-91 and the Johnson-Weibull analysis. The ASTM method did not statistically distinguish between AL 6010 and AL 7075. Based on the Johnson-Weibull analysis confidence numbers greater than 99 percent, AL 2024 was found to have the longest fatigue life, followed by AL 7075, and then AL 6061. The ASTM Standard and the Johnson-Weibull analysis result in the same stress-life exponent p for each of the three aluminum alloys at the median or L(sub 50) lives.
Improving information retrieval in functional analysis.
Rodriguez, Juan C; González, Germán A; Fresno, Cristóbal; Llera, Andrea S; Fernández, Elmer A
2016-12-01
Transcriptome analysis is essential to understand the mechanisms regulating key biological processes and functions. The first step usually consists of identifying candidate genes; to find out which pathways are affected by those genes, however, functional analysis (FA) is mandatory. The most frequently used strategies for this purpose are Gene Set and Singular Enrichment Analysis (GSEA and SEA) over Gene Ontology. Several statistical methods have been developed and compared in terms of computational efficiency and/or statistical appropriateness. However, whether their results are similar or complementary, the sensitivity to parameter settings, or possible bias in the analyzed terms has not been addressed so far. Here, two GSEA and four SEA methods and their parameter combinations were evaluated in six datasets by comparing two breast cancer subtypes with well-known differences in genetic background and patient outcomes. We show that GSEA and SEA lead to different results depending on the chosen statistic, model and/or parameters. Both approaches provide complementary results from a biological perspective. Hence, an Integrative Functional Analysis (IFA) tool is proposed to improve information retrieval in FA. It provides a common gene expression analytic framework that grants a comprehensive and coherent analysis. Only a minimal user parameter setting is required, since the best SEA/GSEA alternatives are integrated. IFA utility was demonstrated by evaluating four prostate cancer and the TCGA breast cancer microarray datasets, which showed its biological generalization capabilities. Copyright © 2016 Elsevier Ltd. All rights reserved.
Poverty in Latin America: A Critical Analysis of Three Studies.
ERIC Educational Resources Information Center
Boltvinik, Julio
1996-01-01
Critically evaluates the methodologies used in three recent studies on poverty in Latin America. Maintains that some studies measure the relative nature of nutritional poverty while others record the absolute nature of nutritional poverty (physical survival). Includes a comparative analysis of the studies' results. (MJP)
Cross-Cultural Analysis of E-Mail Reference
ERIC Educational Resources Information Center
Shachaf, Pnina; Meho, Lokman I.; Hara, Noriko
2007-01-01
Studies that examined virtual reference and its potential for collaboration have by and large represented experiences in western English-speaking countries. This article reports the results of a three-nation (Israel, Japan, and Lebanon) comparative analysis to bridge this research gap. Similarities and differences between these countries highlight…
Meta-analysis of individual registry results enhances international registry collaboration.
Paxton, Elizabeth W; Mohaddes, Maziar; Laaksonen, Inari; Lorimer, Michelle; Graves, Stephen E; Malchau, Henrik; Namba, Robert S; Kärrholm, John; Rolfson, Ola; Cafri, Guy
2018-03-28
Background and purpose - Although common in medical research, meta-analysis has not been widely adopted in registry collaborations. A meta-analytic approach in which each registry conducts a standardized analysis on its own data followed by a meta-analysis to calculate a weighted average of the estimates allows collaboration without sharing patient-level data. The value of meta-analysis as an alternative to individual patient data analysis is illustrated in this study by comparing the risk of revision of porous tantalum cups versus other uncemented cups in primary total hip arthroplasties from Sweden, Australia, and a US registry (2003-2015). Patients and methods - For both individual patient data analysis and meta-analysis approaches a Cox proportional hazard model was fit for time to revision, comparing porous tantalum (n = 23,201) with other uncemented cups (n = 128,321). Covariates included age, sex, diagnosis, head size, and stem fixation. In the meta-analysis approach, treatment effect size (i.e., Cox model hazard ratio) was calculated within each registry and a weighted average for the individual registries' estimates was calculated. Results - Patient-level data analysis and meta-analytic approaches yielded the same results with the porous tantalum cups having a higher risk of revision than other uncemented cups (HR (95% CI) 1.6 (1.4-1.7) and HR (95% CI) 1.5 (1.4-1.7), respectively). Adding the US cohort to the meta-analysis led to greater generalizability, increased precision of the treatment effect, and similar findings (HR (95% CI) 1.6 (1.4-1.7)) with increased risk of porous tantalum cups. Interpretation - The meta-analytic technique is a viable option to address privacy, security, and data ownership concerns allowing more expansive registry collaboration, greater generalizability, and increased precision of treatment effects.
Construction of phylogenetic trees by kernel-based comparative analysis of metabolic networks.
Oh, S June; Joung, Je-Gun; Chang, Jeong-Ho; Zhang, Byoung-Tak
2006-06-06
To infer the tree of life requires knowledge of the common characteristics of each species descended from a common ancestor as the measuring criteria and a method to calculate the distance between the resulting values of each measure. Conventional phylogenetic analysis based on genomic sequences provides information about the genetic relationships between different organisms. In contrast, comparative analysis of metabolic pathways in different organisms can yield insights into their functional relationships under different physiological conditions. However, evaluating the similarities or differences between metabolic networks is a computationally challenging problem, and systematic methods of doing this are desirable. Here we introduce a graph-kernel method for computing the similarity between metabolic networks in polynomial time, and use it to profile metabolic pathways and to construct phylogenetic trees. To compare the structures of metabolic networks in organisms, we adopted the exponential graph kernel, which is a kernel-based approach with a labeled graph that includes a label matrix and an adjacency matrix. To construct the phylogenetic trees, we used an unweighted pair-group method with arithmetic mean, i.e., a hierarchical clustering algorithm. We applied the kernel-based network profiling method in a comparative analysis of nine carbohydrate metabolic networks from 81 biological species encompassing Archaea, Eukaryota, and Eubacteria. The resulting phylogenetic hierarchies generally support the tripartite scheme of three domains rather than the two domains of prokaryotes and eukaryotes. By combining the kernel machines with metabolic information, the method infers the context of biosphere development that covers physiological events required for adaptation by genetic reconstruction. The results show that one may obtain a global view of the tree of life by comparing the metabolic pathway structures using meta-level information rather than sequence information. This method may yield further information about biological evolution, such as the history of horizontal transfer of each gene, by studying the detailed structure of the phylogenetic tree constructed by the kernel-based method.
Tarling, Maggie; Jones, Anne; Murrells, Trevor; McCutcheon, Helen
2017-01-01
Objectives The main aim of the study was to explore the potential sources of variation and understand the meaning of safety climate for nursing practice in acute hospital settings in the UK. Design A sequential mixed methods design included a cross-sectional survey using the Safety Climate Questionnaire (SCQ) and thematic analysis of focus group discussions. Confirmatory factor analysis (CFA) was used to validate the factor structure of the SCQ. Factor scores were compared between nurses working in operating theatres, critical care and ward areas. Results from the survey and the thematic analysis were then compared and synthesised. Setting A London University. Participants 319 registered nurses working in acute hospital settings completed the SCQ and a further 23 nurses participated in focus groups. Results CFA indicated that there was a good model fit on some criteria (χ2=1683.699, df=824, p<0.001; χ2/df=2.04; root mean square error of approximation=0.058) but a less acceptable fit on comparative fit index which is 0.804. There was a statistically significant difference between clinical specialisms in management commitment (F (4,266)=4.66, p=0.001). Nurses working in operating theatres had lower scores compared with ward areas and they also reported negative perceptions about management in their focus group. There was significant variation in scores for communication across clinical specialism (F (4,266)=2.62, p=0.035) but none of the pairwise comparisons achieved statistical significance. Thematic analysis identified themes of human factors, clinical management and protecting patients. The system and the human side of caring was identified as a meta-theme. Conclusions The results suggest that the SCQ has some utility but requires further exploration. The findings indicate that safety in nursing practice is a complex interaction between safety systems and the social and interpersonal aspects of clinical practice. PMID:29084793
Evaluation of a new imaging tool for use with major trauma cases in the emergency department.
Crönlein, Moritz; Holzapfel, Konstantin; Beirer, Marc; Postl, Lukas; Kanz, Karl-Georg; Pförringer, Dominik; Huber-Wagner, Stefan; Biberthaler, Peter; Kirchhoff, Chlodwig
2016-11-17
The aim of this study was to evaluate potential benefits of a new diagnostic software prototype (Trauma Viewer, TV) automatically reformatting computed tomography (CT) data on diagnostic speed and quality, compared to CT-image data evaluation using a conventional CT console. Multiple trauma CT data sets were analysed by one expert radiology and one expert traumatology fellow independently twice, once using the TV and once using the secondary conventional CT console placed in the CT control room. Actual analysis time and precision of diagnoses assessment were evaluated. The TV and CT-console results were compared respectively, but also a comparison to the initial multiple trauma CT reports assessed by emergency radiology fellows considered as the gold standard was performed. Finally, design and function of the Trauma Viewer were evaluated in a descriptive manner. CT data sets of 30 multiple trauma patients were enrolled. Mean time needed for analysis of one CT dataset was 2.43 min using the CT console and 3.58 min using the TV respectively. Thus, secondary conventional CT console analysis was on average 1.15 min shorter compared to the TV analysis. Both readers missed a total of 11 diagnoses using the secondary conventional CT console compared to 12 missed diagnoses using the TV. However, none of these overlooked diagnoses resulted in an Abbreviated Injury Scale (AIS) > 2 corresponding to life threatening injuries. Even though it took the two expert fellows a little longer to analyse the CT scans on the prototype TV compared to the CT console, which can be explained by the new user interface of the TV, our preliminary results demonstrate that, after further development, the TV might serve as a new diagnostic feature in the trauma room management. Its high potential to improve time and quality of CT-based diagnoses might help in fast decision making regarding treatment of severely injured patients.
A Model Comparison for Characterizing Protein Motions from Structure
NASA Astrophysics Data System (ADS)
David, Charles; Jacobs, Donald
2011-10-01
A comparative study is made using three computational models that characterize native state dynamics starting from known protein structures taken from four distinct SCOP classifications. A geometrical simulation is performed, and the results are compared to the elastic network model and molecular dynamics. The essential dynamics is quantified by a direct analysis of a mode subspace constructed from ANM and a principal component analysis on both the FRODA and MD trajectories using root mean square inner product and principal angles. Relative subspace sizes and overlaps are visualized using the projection of displacement vectors on the model modes. Additionally, a mode subspace is constructed from PCA on an exemplar set of X-ray crystal structures in order to determine similarly with respect to the generated ensembles. Quantitative analysis reveals there is significant overlap across the three model subspaces and the model independent subspace. These results indicate that structure is the key determinant for native state dynamics.
MTF measurements on real time for performance analysis of electro-optical systems
NASA Astrophysics Data System (ADS)
Stuchi, Jose Augusto; Signoreto Barbarini, Elisa; Vieira, Flavio Pascoal; dos Santos, Daniel, Jr.; Stefani, Mário Antonio; Yasuoka, Fatima Maria Mitsue; Castro Neto, Jarbas C.; Linhari Rodrigues, Evandro Luis
2012-06-01
The need of methods and tools that assist in determining the performance of optical systems is actually increasing. One of the most used methods to perform analysis of optical systems is to measure the Modulation Transfer Function (MTF). The MTF represents a direct and quantitative verification of the image quality. This paper presents the implementation of the software, in order to calculate the MTF of electro-optical systems. The software was used for calculating the MTF of Digital Fundus Camera, Thermal Imager and Ophthalmologic Surgery Microscope. The MTF information aids the analysis of alignment and measurement of optical quality, and also defines the limit resolution of optical systems. The results obtained with the Fundus Camera and Thermal Imager was compared with the theoretical values. For the Microscope, the results were compared with MTF measured of Microscope Zeiss model, which is the quality standard of ophthalmological microscope.
Simplified welding distortion analysis for fillet welding using composite shell elements
NASA Astrophysics Data System (ADS)
Kim, Mingyu; Kang, Minseok; Chung, Hyun
2015-09-01
This paper presents the simplified welding distortion analysis method to predict the welding deformation of both plate and stiffener in fillet welds. Currently, the methods based on equivalent thermal strain like Strain as Direct Boundary (SDB) has been widely used due to effective prediction of welding deformation. Regarding the fillet welding, however, those methods cannot represent deformation of both members at once since the temperature degree of freedom is shared at the intersection nodes in both members. In this paper, we propose new approach to simulate deformation of both members. The method can simulate fillet weld deformations by employing composite shell element and using different thermal expansion coefficients according to thickness direction with fixed temperature at intersection nodes. For verification purpose, we compare of result from experiments, 3D thermo elastic plastic analysis, SDB method and proposed method. Compared of experiments results, the proposed method can effectively predict welding deformation for fillet welds.
Zhu, Tian; Cao, Shuyi; Su, Pin-Chih; Patel, Ram; Shah, Darshan; Chokshi, Heta B; Szukala, Richard; Johnson, Michael E; Hevener, Kirk E
2013-09-12
A critical analysis of virtual screening results published between 2007 and 2011 was performed. The activity of reported hit compounds from over 400 studies was compared to their hit identification criteria. Hit rates and ligand efficiencies were calculated to assist in these analyses, and the results were compared with factors such as the size of the virtual library and the number of compounds tested. A series of promiscuity, druglike, and ADMET filters were applied to the reported hits to assess the quality of compounds reported, and a careful analysis of a subset of the studies that presented hit optimization was performed. These data allowed us to make several practical recommendations with respect to selection of compounds for experimental testing, definition of hit identification criteria, and general virtual screening hit criteria to allow for realistic hit optimization. A key recommendation is the use of size-targeted ligand efficiency values as hit identification criteria.
3D analysis of eddy current loss in the permanent magnet coupling.
Zhu, Zina; Meng, Zhuo
2016-07-01
This paper first presents a 3D analytical model for analyzing the radial air-gap magnetic field between the inner and outer magnetic rotors of the permanent magnet couplings by using the Amperian current model. Based on the air-gap field analysis, the eddy current loss in the isolation cover is predicted according to the Maxwell's equations. A 3D finite element analysis model is constructed to analyze the magnetic field spatial distributions and vector eddy currents, and then the simulation results obtained are analyzed and compared with the analytical method. Finally, the current losses of two types of practical magnet couplings are measured in the experiment to compare with the theoretical results. It is concluded that the 3D analytical method of eddy current loss in the magnet coupling is viable and could be used for the eddy current loss prediction of magnet couplings.
A comparative appraisal of hydrological behavior of SRTM DEM at catchment level
NASA Astrophysics Data System (ADS)
Sharma, Arabinda; Tiwari, K. N.
2014-11-01
The Shuttle Radar Topography Mission (SRTM) data has emerged as a global elevation data in the past one decade because of its free availability, homogeneity and consistent accuracy compared to other global elevation dataset. The present study explores the consistency in hydrological behavior of the SRTM digital elevation model (DEM) with reference to easily available regional 20 m contour interpolated DEM (TOPO DEM). Analysis ranging from simple vertical accuracy assessment to hydrological simulation of the studied Maithon catchment, using empirical USLE model and semidistributed, physical SWAT model, were carried out. Moreover, terrain analysis involving hydrological indices was performed for comparative assessment of the SRTM DEM with respect to TOPO DEM. Results reveal that the vertical accuracy of SRTM DEM (±27.58 m) in the region is less than the specified standard (±16 m). Statistical analysis of hydrological indices such as topographic wetness index (TWI), stream power index (SPI), slope length factor (SLF) and geometry number (GN) shows a significant differences in hydrological properties of the two studied DEMs. Estimation of soil erosion potentials of the catchment and conservation priorities of microwatersheds of the catchment using SRTM DEM and TOPO DEM produce considerably different results. Prediction of soil erosion potential using SRTM DEM is far higher than that obtained using TOPO DEM. Similarly, conservation priorities determined using the two DEMs are found to be agreed for only 34% of microwatersheds of the catchment. ArcSWAT simulation reveals that runoff predictions are less sensitive to selection of the two DEMs as compared to sediment yield prediction. The results obtained in the present study are vital to hydrological analysis as it helps understanding the hydrological behavior of the DEM without being influenced by the model structural as well as parameter uncertainty. It also reemphasized that SRTM DEM can be a valuable dataset for hydrological analysis provided any error/uncertainty therein is being properly evaluated and characterized.
Rao, Shuquan; Kota, Lakshmi Narayanan; Li, Zongchang; Yao, Yao; Tang, Jinsong; Mao, Canquan; Jain, Sanjeev; Xu, Yong; Xu, Qi
2016-08-01
Human telomeres consist of tandem nucleotide repeats (TTAGGG) and associated proteins, and telomere length (TL) is reduced progressively with cell division over the lifespan. Telomere erosion might be accelerated or prevented to varying degrees when exposure to serious medical illnesses. In previous studies, an association between TL decrease and schizophrenia has been extensively reported; however, the results remain largely controversial. To further investigate TL in schizophrenia patients and reconcile this controversy, we first measured leucocyte TL (LTL) in our samples (52 paranoid schizophrenia, 89 non-paranoid patients and 120 controls), and then conducted a comprehensive meta-analysis of the existing results of LTL in patients of schizophrenia compared to healthy subjects. Totally, 11 studies encompassing 1243 patients of schizophrenia and 1274 controls were included in the final meta-analysis model. In our samples, significant reduction of LTL in paranoid schizophrenia was observed compared to controls (F = 50.88, P < 0.001); whereas there was no significant difference in LTL between non-paranoid schizophrenia and controls (F = 0.842, P = 0.360). For meta-analysis, random-effects model showed significant LTL decrease in patients of schizophrenia when compared to controls (Z = 2.07, P = 0.039, SMD = -0.48, 95% CI = -0.94 to -0.03). Moreover, a marginal decrease in LTL was observed in medicated patients (Z = 1.92, P = 0.055, SMD = -0.58, 95% CI = -1.18-0.01) and those patients with poor response to antipsychotics (Z = 1.76, P = 0.078, SMD = -0.60, 95% CI = -1.27-0.07). In conclusion, we observed significant reduction of LTL in individuals with schizophrenia compared with controls. However, all the studies included in the meta-analysis were cross-sectional, and better controlled long-term studies are needed to replicate this result. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lloveras, Diego G.; Vásquez, Alberto M.; Nuevo, Federico A.; Frazin, Richard A.
2017-10-01
Using differential emission measure tomography (DEMT) based on time series of EUV images, we carry out a quantitative comparative analysis of the three-dimensional (3D) structure of the electron density and temperature of the inner corona (r<1.25 R_{⊙}) between two specific rotations selected from the last two solar minima, namely Carrington Rotations (CR)1915 and CR-2081. The analysis places error bars on the results because of the systematic uncertainty of the sources. While the results for CR-2081 are characterized by a remarkable north-south symmetry, the southern hemisphere for CR-1915 exhibits higher densities and temperatures than the northern hemisphere. The core region of the streamer belt in both rotations is found to be populated by structures whose temperature decreases with height (called "down loops" in our previous articles). They are characterized by plasma β≳1, and may be the result of the efficient dissipation of Alfvén waves at low coronal heights. The comparative analysis reveals that the low latitudes of the equatorial streamer belt of CR-1915 exhibit higher densities than for CR-2081. This cannot be explained by the systematic uncertainties. In addition, the southern hemisphere of the streamer belt of CR-1915 is characterized by higher temperatures and density scale heights than for CR-2081. On the other hand, the coronal hole region of CR-1915 shows lower temperatures than for CR-2081. The reported differences are in the range ≈ 10 - 25%, depending on the specific physical quantity and region that is compared, as fully detailed in the analysis. For other regions and/or physical quantities, the uncertainties do not allow assessing the thermodynamical differences between the two rotations. Future investigation will involve a DEMT analysis of other Carrington rotations selected from both epochs, and also a comparison of their tomographic reconstructions with magnetohydrodynamical simulations of the inner corona.
Summary of ionizing radiation analysis on the Long Duration Exposure Facility
NASA Technical Reports Server (NTRS)
Parnell, T. A.
1991-01-01
The Ionizing Radiation Special Investigation Group (IRSIG) for the Long Duration Exposure Facility (LDEF) was established to perform radiation measurements and analysis not planned in the original experiments, and to assure availability of LDEF analysis results in a form useful to future missions. The IRSIG has organized extensive induced radioactivity measurements throughout LDEF, and a comprehensive program to compare the LDEF radiation measurements to values calculated using environment models. The activities and present status of the Group is described. The ionizing radiation results presented is summarized.
NASA Technical Reports Server (NTRS)
Mcfarland, E.; Tabakoff, W.; Hamed, A.
1977-01-01
An investigation of the effects of coolant injection on the aerodynamic performance of cooled turbine blades is presented. The coolant injection is modeled in the inviscid irrotational adiabatic flow analysis through the cascade using the distributed singularities approach. The resulting integral equations are solved using a minimized surface singularity density criteria. The aerodynamic performance was evaluated using this solution in conjunction with an existing mixing theory analysis. The results of the present analysis are compared with experimental measurements in cold flow tests.
Men'shikov, V V
2012-12-01
The article deals with the factors impacting the reliability of clinical laboratory information. The differences of qualities of laboratory analysis tools produced by various manufacturers are discussed. These characteristics are the causes of discrepancy of the results of laboratory analyses of the same analite. The role of the reference system in supporting the comparability of laboratory analysis results is demonstrated. The project of national standard is presented to regulate the requirements to standards and calibrators for analysis of qualitative and non-metrical characteristics of components of biomaterials.
Validation of a three-dimensional viscous analysis of axisymmetric supersonic inlet flow fields
NASA Technical Reports Server (NTRS)
Benson, T. J.; Anderson, B. H.
1983-01-01
A three-dimensional viscous marching analysis for supersonic inlets was developed. To verify this analysis several benchmark axisymmetric test configurations were studied and are compared to experimental data. Detailed two-dimensional results for shock-boundary layer interactions are presented for flows with and without boundary layer bleed. Three dimensional calculations of a cone at angle of attack and a full inlet at attack are also discussed and evaluated. Results of the calculations demonstrate the code's ability to predict complex flow fields and establish guidelines for future calculations using similar codes.
Experimental and Numerical Analysis of Screw Fixation in Anterior Cruciate Ligament Reconstruction
NASA Astrophysics Data System (ADS)
Chizari, Mahmoud; Wang, Bin; Snow, Martyn; Barrett, Mel
2008-09-01
This paper reports the results of an experimental and finite element analysis of tibial screw fixation in anterior cruciate ligament (ACL) reconstruction. The mechanical properties of the bone and tendon graft are obtained from experiments using porcine bone and bovine tendon. The results of the numerical study are compared with those from mechanical testing. Analysis shows that the model may be used to establish the optimum placement of the tunnel in anterior cruciate ligament reconstruction by predicting mechanical parameters such as stress, strain and displacement at regions in the tunnel wall.
Boyd, Courtney; Crawford, Cindy; Paat, Charmagne F; Price, Ashley; Xenakis, Lea; Zhang, Weimin
2016-09-01
Pain is multi-dimensional and may be better addressed through a holistic, biopsychosocial approach. Massage therapy is commonly practiced among patients seeking pain management; however, its efficacy is unclear. This systematic review and meta-analysis is the first to rigorously assess the quality of the evidence for massage therapy's efficacy in treating pain, function-related, and health-related quality of life outcomes in surgical pain populations. Key databases were searched from inception through February 2014. Eligible randomized controlled trials were assessed for methodological quality using SIGN 50 Checklist. Meta-analysis was applied at the outcome level. A professionally diverse steering committee interpreted the results to develop recommendations. Twelve high quality and four low quality studies were included in the review. Results indicate massage therapy is effective for treating pain [standardized mean difference (SMD) = -0.79] and anxiety (SMD = -0.57) compared to active comparators. Based on the available evidence, weak recommendations are suggested for massage therapy, compared to active comparators for reducing pain intensity/severity and anxiety in patients undergoing surgical procedures. This review also discusses massage therapy safety, challenges within this research field, how to address identified research gaps, and next steps for future research. © 2016 American Academy of Pain Medicine.
Lee, Ki Song; Choe, Young Chan; Park, Sung Hee
2015-10-01
This study examined the structural variables affecting the environmental effects of organic farming compared to those of conventional farming. A meta-analysis based on 107 studies and 360 observations published from 1977 to 2012 compared energy efficiency (EE) and greenhouse gas emissions (GHGE) for organic and conventional farming. The meta-analysis systematically analyzed the results of earlier comparative studies and used logistic regression to identify the structural variables that contributed to differences in the effects of organic and conventional farming on the environment. The statistical evidence identified characteristics that differentiated the environmental effects of organic and conventional farming, which is controversial. The results indicated that data sources, sample size and product type significantly affected EE, whereas product type, cropping pattern and measurement unit significantly affected the GHGE of organic farming compared to conventional farming. Superior effects of organic farming on the environment were more likely to appear for larger samples, primary data rather than secondary data, monocropping rather than multicropping, and crops other than fruits and vegetables. The environmental effects of organic farming were not affected by the study period, geographic location, farm size, cropping pattern, or measurement method. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Coastal sea level measurements using a single geodetic GPS receiver
NASA Astrophysics Data System (ADS)
Larson, Kristine M.; Löfgren, Johan S.; Haas, Rüdiger
2013-04-01
This paper presents a method to derive local sea level variations using data from a single geodetic-quality Global Navigation Satellite System (GNSS) receiver using GPS (Global Positioning System) signals. This method is based on multipath theory for specular reflections and the use of Signal-to-Noise Ratio (SNR) data. The technique could be valuable for altimeter calibration and validation. Data from two test sites, a dedicated GPS tide gauge at the Onsala Space Observatory (OSO) in Sweden and the Friday Harbor GPS site of the EarthScope Plate Boundary Observatory (PBO) in USA, are analyzed. The sea level results are compared to independently observed sea level data from nearby and in situ tide gauges. For OSO, the Root-Mean-Square (RMS) agreement is better than 5 cm, while it is in the order of 10 cm for Friday Harbor. The correlation coefficients are better than 0.97 for both sites. For OSO, the SNR-based results are also compared with results from a geodetic analysis of GPS data of a two receivers/antennae tide gauge installation. The SNR-based analysis results in a slightly worse RMS agreement with respect to the independent tide gauge data than the geodetic analysis (4.8 cm and 4.0 cm, respectively). However, it provides results even for rough sea surface conditions when the two receivers/antennae installation no longer records the necessary data for a geodetic analysis.
Gączarzewicz, D
2015-01-01
The objective of the study was to evaluate the effect of different types of chambers used in computer-assisted semen analysis (CASA) on boar sperm concentration and motility parameters. CASA measurements were performed on 45 ejaculates by comparing three commonly used chambers: Leja chamber (LJ), Makler chamber (MK) and microscopic slide-coverslip (SL). Concentration results obtained with CASA were verified by manual counting on a Bürker hemocytometer (BH). No significant differences were found between the concentrations determined with BH vs. LJ and SL, whereas higher (p<0.01) values of this parameter were obtained with MK. Compared to MK and SL, significantly higher values were recorded in LJ for velocity (VCL and VAP) as well as amplitude of the lateral head displacement (ALH) and beat cross frequency (BCF), which was associated with significantly higher percentages of motile, progressively motile and rapidly progressive motile spermatozoa. Higher values for the linearity (LIN) and straightness (STR) of sperm movement were obtained for the analysis performed in MK and SL. In both these chambers, the results of all the linearity and kinetic parameters of sperm were similar (p>0.05). The results obtained show that CASA assessment of boar semen should account for the effect of counting chamber on the results of sperm motility and concentration, which confirms the need for further study on standardizing the automatic analysis of boar semen.
Thuerlimann, Beat
2007-01-01
The BIG 1-98 trial is a large, randomized, independently conducted clinical trial designed to compare the efficacy of upfront letrozole versus tamoxifen monotherapy and to compare sequential or up-front use of letrozole and/or tamoxifen as an early adjuvant therapy for patients with early breast cancer. We report on the results from the primary core analysis of the BIG 1-98 trial of 8,010 patients, which compares monotherapy with letrozole versus tamoxifen. This pre-planned core analysis allowed the use of patient data from the monotherapy arms of letrozole and tamoxifen and from the sequential arms prior to the drug switch point. Patients randomized to letrozole had a 19% improved disease-free survival (hazard ratio [HR] = 0.81; P = 0.003), due especially to reduced distant metastases (HR = 0.73; P = 0.001). A 14% risk reduction of fatal events in favor of letrozole was also observed (P = NS). The results from the monotherapy arms alone confirmed the findings from the primary core analysis. Based on the results from this trial, the aromatase inhibitor letrozole (Femara®) is currently recommended as a part of standard adjuvant therapy for postmenopausal women with endocrine-responsive breast cancer and has recently been approved in the early adjuvant setting in both Europe and the United States. A subsequent analysis after additional follow-up will address the question of monotherapy versus sequential therapy. PMID:17912636
Cost Analysis of a Novel Enzymatic Debriding Agent for Management of Burn Wounds.
Giudice, Giuseppe; Filoni, Angela; Maggio, Giulio; Bonamonte, Domenico; Vestita, Michelangelo
2017-01-01
Introduction . Given its efficacy and safety, NexoBrid™ (NXB) has become part of our therapeutic options in burns treatment with satisfactory results. However, no cost analysis comparing NXB to the standard of care (SOC) has been carried out as of today. Aim . To assess the cost of treatment with NXB and compare it to the SOC cost. Methods . 20 patients with 14-22% of TBSA with an intermediate-deep thermal burn related injury were retrospectively and consecutively included. 10 of these patients were treated with the SOC, while the other 10 with NXB. The cost analysis was performed in accordance with the weighted average Italian Health Ministry DRGs and with Conferenza Stato/Regioni 2003 and the study by Tan et al. For each cost, 95% confidence intervals have been evaluated. Results . Considering the 10 patients treated with NXB, the overall savings (total net saving) amounted to 53300 euros. The confidence interval analysis confirmed the savings. Discussion . As shown by our preliminary results, significant savings are obtained with the use of NXB. The limit of our study is that it is based on Italian health care costs and assesses a relative small cohort of patients. Further studies on larger multinational cohorts are warranted.
NASA Technical Reports Server (NTRS)
Anusonti-Inthra, Phuriwat
2010-01-01
This paper presents validations of a novel rotorcraft analysis that coupled Computational Fluid Dynamics (CFD), Computational Structural Dynamics (CSD), and Particle Vortex Transport Method (PVTM) methodologies. The CSD with associated vehicle trim analysis is used to calculate blade deformations and trim parameters. The near body CFD analysis is employed to provide detailed near body flow field information which is used to obtain high-fidelity blade aerodynamic loadings. The far field wake dominated region is simulated using the PVTM analysis which provides accurate prediction of the evolution of the rotor wake released from the near body CFD domains. A loose coupling methodology between the CSD and CFD/PVTM modules are used with appropriate information exchange amongst the CSD/CFD/PVTM modules. The coupled CSD/CFD/PVTM methodology is used to simulate various rotorcraft flight conditions (i.e. hover, transition, and high speed flights), and the results are compared with several sets of experimental data. For the hover condition, the results are compared with hover data for the HART II rotor tested at DLR Institute of Flight Systems, Germany. For the forward flight conditions, the results are validated with the UH-60A flight test data.
NASA Astrophysics Data System (ADS)
Agapov, Vladimir
2018-03-01
The necessity of new approaches to the modeling of rods in the analysis of high-rise constructions is justified. The possibility of the application of the three-dimensional superelements of rods with rectangular cross section for the static and dynamic calculation of the bar and combined structures is considered. The results of the eighteen-story spatial frame free vibrations analysis using both one-dimensional and three-dimensional models of rods are presented. A comparative analysis of the obtained results is carried out and the conclusions on the possibility of three-dimensional superelements application in static and dynamic analysis of high-rise constructions are given on its basis.
Comparative analysis of heat pump and biomass boiler for small detached house heating
NASA Astrophysics Data System (ADS)
Olkowski, Tomasz; Lipiński, Seweryn; Olędzka, Aneta
2017-10-01
The purpose of the work is to answer the question - which of the two selected heat sources is more economically beneficial for small detached house: heat pump or biomass boiler fuelled with wood-pellets? The comparative analysis of these sources was carried out to discuss the issue. First, cost of both, equipment and operation of selected heat systems were analysed. Additionally, CO2 emission levels associated with these heat systems were determined. The comparative analysis of the costs of both considered heat systems showed that equipment cost of heat pump system is considerably bigger than the cost of biomass boiler system. The comparison of annual operation costs showed that heat pump operation cost is slightly lower than operation cost of biomass boiler. The analysis of above results shows that lower operation cost of heat pump in comparison with biomass boiler cost lets qualify heat pump as more economically justified only after 38 years of work. For both analysed devices, CO2 emission levels were determined. The considerations take into account the fact that heat pump consumes electricity. It is mostly generated through combustion of coal in Poland. The results show that in Poland biomass boiler can be described as not only more economically justified system but also as considerably more ecological.
NASA Astrophysics Data System (ADS)
Einstein, Theodore L.; Pimpinelli, Alberto; González, Diego Luis; Morales-Cifuentes, Josue R.
2015-09-01
In studies of epitaxial growth, analysis of the distribution of the areas of capture zones (i.e. proximity polygons or Voronoi tessellations with respect to island centers) is often the best way to extract the critical nucleus size i. For non-random nucleation the normalized areas s of these Voronoi cells are well described by the generalized Wigner distribution (GWD) Pβ(s) = asβ exp(-bs2), particularly in the central region 0.5 < s < 2 where data are least noisy. Extensive Monte Carlo simulations reveal inadequacies of our earlier mean field analysis, suggesting β = i + 2 for diffusion-limited aggregation (DLA). Since simulations generate orders of magnitude more data than experiments, they permit close examination of the tails of the distribution, which differ from the simple GWD form. One refinement is based on a fragmentation model. We also compare island-size distributions. We compare analysis by island-size distribution and by scaling of island density with flux. Modifications appear for attach-limited aggregation (ALA). We focus on the experimental system para-hexaphenyl on amorphous mica, comparing the results of the three analysis techniques and reconciling their results via a novel model of hot precursors based on rate equations, pointing out the existence of intermediate scaling regimes between DLA and ALA.
Sex While Intoxicated: A Meta-Analysis Comparing Heterosexual and Sexual Minority Youth
Herrick, Amy L.; Marshal, Michael P.; Smith, Helen A.; Sucato, Gina; Stall, Ron D.
2013-01-01
Background The social marginalization and victimization experienced by sexual minority youth (SMY) may lead to increased risk behaviors and higher rates of negative health outcomes compared with their heterosexual peers. Methods We conducted a meta-analysis to examine whether SMY reported higher rates of sex while intoxicated. Studies that report rates of substance use during sex in both SMY and heterosexual youth and had a mean participant age of 18 or less were included in our meta-analysis. Effect sizes were extracted from six studies (nine independent data sets and 24 effect sizes) that met study criteria and had high inter-rater reliability (.98). Results Results indicated that SMY were almost twice as likely to report sex while intoxicated as compared with heterosexual peers. A random-effects meta-analysis showed a moderate ([overall weighted effect OR]= 1.91, p < .0001) weighted effect size for the relationship between sexual orientation and the use of drugs at the time of sexual intercourse, with the mean effect size for each study ranging from 1.21 to 3.50 and individual effect sizes ranging from .35 to 9.86. Discussion Our findings highlight the need for healthcare providers to screen SMY for participation in substance use during sexual intercourse and to offer risk reduction counseling during office visits. PMID:21338904
Cost per responder of TNF-α therapies in Germany.
Gissel, Christian; Repp, Holger
2013-12-01
Tumor necrosis factor α (TNF-α) inhibitors ranked highest in German pharmaceutical expenditure in 2011. Their most important application is the treatment of rheumatoid arthritis (RA). Our objective is to analyze cost per responder of TNF-α inhibitors for RA from the German Statutory Health Insurance funds' perspective. We aim to conduct the analysis based on randomized comparative effectiveness studies of the relevant treatments for the German setting. For inclusion of effectiveness studies, we require results in terms of response rates as defined by European League Against Rheumatism (EULAR) or American College of Rheumatology (ACR) criteria. We identify conventional triple therapy as the relevant comparator. We calculate cost per responder based on German direct medical costs. Direct clinical comparisons could be identified for both etanercept and infliximab compared to triple therapy. For infliximab, cost per responder was 216,392 euros for ACR50 and 432,784 euros for ACR70 responses. For etanercept, cost per ACR70 responder was 321,527 euros. Cost was lower for response defined by EULAR criteria, but data was only available for infliximab. Cost per responder is overestimated by 40% due to inclusion of taxes and mandatory rebates in German drugs' list prices. Our analysis shows specific requirements for cost-effectiveness analysis in Germany. Cost per responder for TNF-α treatment in the German setting is more than double the cost estimated in a similar analysis for the USA, which measured against placebo. The difference in results shows the critical role of the correct comparator for a specific setting.
Globalization and Its Influence on Comparative Education Methodology
ERIC Educational Resources Information Center
Chigisheva, Oksana
2015-01-01
The article is devoted to the research of the methodological changes that occur in the field of comparative education as a result of globalization. A deep analysis of the globalization phenomenon is undertaken with a special focus on the differentiation of globalization, internationalisation, regionalisation and integration. UNESCO's role in the…
Marriage Type and Reproductive Decisions: A Comparative Study in Sub-Saharan Africa.
ERIC Educational Resources Information Center
Dodoo, F. Nii-Amoo
1998-01-01
The effect of marriage type (polygamy vs. monogamy) on reproductive decisions is investigated using comparative data from the 1988, 1989, and 1993 Demographic and Health Surveys of Ghana and Kenya. Multivariate analysis is used. Inconclusive results are discussed with a focus on future research directions. (Author/EMK)
Comparative Analysis of Monographic Collections in Nursing.
ERIC Educational Resources Information Center
Bowden, Virginia M.; And Others
The results of a project comparing the nursing monograph collections of academic health science center libraries in the Southwest are reported. Records for nursing monographs from the TALON (South Central Regional Medical Library Program) Union Catalog of Monographs from 1977-1983 were analyzed to reveal the distribution by year, publisher, and…
This report compares simultaneous results from three woodstove sampling methods and evaluates particulate emission rates of conventional and Oregon-certified catalytic and noncatalytic woodstoves in six Portland, OR, houses. EPA Methods 5G and 5H and the field emission sampler (A...
The utility of laboratory animal data in toxicology depends upon the ability to generalize the results quantitatively to humans. To compare the acute behavioral effects of inhaled toluene in humans to those in animals, dose-effect curves were fitted by meta-analysis of published...
PAH effects on meio- and microbial benthic communities strongly depend on bioavailability.
Lindgren, J Fredrik; Hassellöv, Ida-Maja; Dahllöf, Ingela
2014-01-01
The effects of anthropogenic pollutants in dissimilar habitats can vary depending on differences in bioavailability. The factors determining bioavailability are not yet fully understood. This study was performed to evaluate whether analysis of total PAH concentrations in sediments is a satisfactory measurement to indicate environmental effects or if bioavailability is needed to be taken into account. We have here performed a 60-day experiment, where nominal PAH concentrations of 1,300 μg/kg sediment were added to three different marine sediments. Meiofaunal and microbial communities were analyzed for alterations in community response at 30 and 60 days. Results showed that bioavailability of PAHs varied between the three different sediments. Nonetheless, the petroleum addition gave rise to significant negative effects on all three sediments at both time points. The two direct measurements of toxicity on the microbial community, potential nitrification and denitrification, displayed a lower effect of the PAH addition in the muddy sediment at both time points, compared to the other two sediment types. No effects were seen in the analysis of meiofaunal community structure. Measurements of PAH bioavailability in the three sediment types concurred with the results from the microbial community, revealing a lower bioavailability in the muddy sediment compared to the other two sediment types, 34% compared to sandy and 18% compared to organic at day 0. At day 60 it was 61% lower compared to sandy and 20% lower compared to organic. The negative effects of the PAH addition on the microbial nitrogen cycle were in six out of eight cases best correlated to the amount of alkylated bioavailable PAH in the sediments, and thus microbial nitrogen cycle is a possible good indicator for assessing PAH-induced stress. The results presented here have implications for risk analysis studies of petroleum-contaminated marine sediments; consequently, sediment characteristics and its effects on bioavailability are important to include. In addition, these results add to the understanding that bioavailability measurements of PAHs are a more correct assessment compared to measurements of total PAH concentrations, and need to be included when estimating effects of PAHs in marine benthic communities. Copyright © 2013 Elsevier B.V. All rights reserved.
Kumar, Y Kiran; Mehta, Shashi Bhushan; Ramachandra, Manjunath
2017-01-01
The purpose of this work is to provide some validation methods for evaluating the hemodynamic assessment of Cerebral Arteriovenous Malformation (CAVM). This article emphasizes the importance of validating noninvasive measurements for CAVM patients, which are designed using lumped models for complex vessel structure. The validation of the hemodynamics assessment is based on invasive clinical measurements and cross-validation techniques with the Philips proprietary validated software's Qflow and 2D Perfursion. The modeling results are validated for 30 CAVM patients for 150 vessel locations. Mean flow, diameter, and pressure were compared between modeling results and with clinical/cross validation measurements, using an independent two-tailed Student t test. Exponential regression analysis was used to assess the relationship between blood flow, vessel diameter, and pressure between them. Univariate analysis is used to assess the relationship between vessel diameter, vessel cross-sectional area, AVM volume, AVM pressure, and AVM flow results were performed with linear or exponential regression. Modeling results were compared with clinical measurements from vessel locations of cerebral regions. Also, the model is cross validated with Philips proprietary validated software's Qflow and 2D Perfursion. Our results shows that modeling results and clinical results are nearly matching with a small deviation. In this article, we have validated our modeling results with clinical measurements. The new approach for cross-validation is proposed by demonstrating the accuracy of our results with a validated product in a clinical environment.
NASA Technical Reports Server (NTRS)
Rouse, Marshall; Young, Richard D.; Gehrki, Ralph R.
2003-01-01
Results from an experimental and analytical study of a curved stiffened aluminum panel subjected to combined mechanical and internal pressure loads are presented. The panel loading conditions were simulated using a D-box test fixture. Analytical buckling load results calculated from a finite element analysis are presented and compared to experimental results. Buckling results presented indicate that the buckling load of the fuselage panel is significantly influenced by internal pressure loading. The experimental results suggest that the stress distribution is uniform in the panel prior to buckling. Nonlinear finite element analysis results correlates well with experimental results up to buckling.
Development of HAN-based Liquid Propellant Thruster
NASA Astrophysics Data System (ADS)
Hisatsune, K.; Izumi, J.; Tsutaya, H.; Furukawa, K.
2004-10-01
Many of propellants that are applied to the conventional spacecraft propulsion system are toxic propellants. Because of its toxicity, considering the environmental pollution or safety on handling, it will be necessary to apply the "green" propellant to the spacecraft propulsion system. The purpose of this study is to apply HAN based liquid propellant (LP1846) to mono propellant thruster. Compared to the hydrazine that is used in conventional mono propellant thruster, HAN based propellant is not only lower toxic but also can obtain higher specific impulse. Moreover, HAN based propellant can be decomposed by the catalyst. It means there are the possibility of applying to the mono propellant thruster that can leads to the high reliability of the propulsion system.[1],[2] However, there are two technical subjects, to apply HAN based propellant to the mono propellant thruster. One is the high combustion temperature. The catalyst will be damaged under high temperature condition. The other is the low catalytic activity. It is the serious problem on application of HAN based propellant to the mono propellant thruster that is used for attitude control of spacecraft. To improve the catalytic activity of HAN based propellant, it is necessary to screen the best catalyst for HAN based propellant. The adsorption analysis is conducted by Monte Carlo Simulation to screen the catalyst metal for HAN and TEAN. The result of analysis shows the Iridium is the best catalyst metal for HAN and TEAN. Iridium is the catalyst metal that is used at conventional mono propellant thruster catalyst Shell405. Then, to confirm the result of analysis, the reaction test about catalyst is conducted. The result of this test is the same as the result of adsorption analysis. That means the adsorption analysis is effective in screening the catalyst metal. At the evaluating test, the various types of carrier of catalyst are also compared to Shell 405 to improve catalytic activity. The test result shows the inorganic porous media is superior to Shell405 in catalytic activity. Next, the catalyst life with HAN based propellant (LP1846) is evaluated. The Shell405 and inorganic porous media catalyst are compared at the life test. The test result shows the inorganic porous media catalyst is superior to Shell405 in catalyst life. In this paper, the detail of the result of adsorption analysis and evaluating test are reported.
Poppe, Katrina K; Doughty, Robert N; Yu, Cheuk-Man; Quintana, Miguel; Møller, Jacob E; Klein, Allan L; Gamble, Greg D; Dini, Frank L; Whalley, Gillian A
2011-04-14
Meta-analyses are increasingly used to summarise observational data however a literature meta-analysis (LMA) may give different results to the corresponding individual patient meta-analysis (IPMA). This study compares the published results of equivalent LMAs and IPMAs, highlighting factors that can affect the results and therefore impact on clinical interpretation of meta-analyses. Univariate results from published meta-analyses of prospective observational outcome data were compared, as were the number of studies, patients and length of follow-up. The absolute difference in survival was calculated. The association between severe diastolic dysfunction (RFP) and death post acute myocardial infarction (AMI) and in chronic heart failure (HF) were used as clinical examples. The IPMA hazard ratio was lower that the LMA odds ratio: AMI hazard ratio 2.67 (95% confidence interval 2.23 to 3.20), odds ratio 4.10 (3.38 to 4.99); HF hazard ratio 2.42 (2.06 to 2.83), odds ratio 4.36 (3.60 to 5.04). The IPMAs contained most of the studies from the LMAs as well as additional unpublished data, and a longer length of follow-up was available in the IPMAs (AMI 3.7 vs 2.6 yr, HF 4.0 vs 1.5 yr). Restricting analysis to the same studies in both the LMA and IPMA resulted in a similar difference in effect sizes between methods to those found in the published analyses. The result of a meta-analysis is affected by whether study level or individual patient data have been used, and the variant of analysis that is required. Awareness and consideration of these factors is important for clinical interpretation of meta-analyses. Copyright © 2009 Elsevier B.V. All rights reserved.
Sensitivity Analysis of Multidisciplinary Rotorcraft Simulations
NASA Technical Reports Server (NTRS)
Wang, Li; Diskin, Boris; Biedron, Robert T.; Nielsen, Eric J.; Bauchau, Olivier A.
2017-01-01
A multidisciplinary sensitivity analysis of rotorcraft simulations involving tightly coupled high-fidelity computational fluid dynamics and comprehensive analysis solvers is presented and evaluated. An unstructured sensitivity-enabled Navier-Stokes solver, FUN3D, and a nonlinear flexible multibody dynamics solver, DYMORE, are coupled to predict the aerodynamic loads and structural responses of helicopter rotor blades. A discretely-consistent adjoint-based sensitivity analysis available in FUN3D provides sensitivities arising from unsteady turbulent flows and unstructured dynamic overset meshes, while a complex-variable approach is used to compute DYMORE structural sensitivities with respect to aerodynamic loads. The multidisciplinary sensitivity analysis is conducted through integrating the sensitivity components from each discipline of the coupled system. Numerical results verify accuracy of the FUN3D/DYMORE system by conducting simulations for a benchmark rotorcraft test model and comparing solutions with established analyses and experimental data. Complex-variable implementation of sensitivity analysis of DYMORE and the coupled FUN3D/DYMORE system is verified by comparing with real-valued analysis and sensitivities. Correctness of adjoint formulations for FUN3D/DYMORE interfaces is verified by comparing adjoint-based and complex-variable sensitivities. Finally, sensitivities of the lift and drag functions obtained by complex-variable FUN3D/DYMORE simulations are compared with sensitivities computed by the multidisciplinary sensitivity analysis, which couples adjoint-based flow and grid sensitivities of FUN3D and FUN3D/DYMORE interfaces with complex-variable sensitivities of DYMORE structural responses.
Jia, Yongliang; Leung, Siu-wai
2015-11-01
There have been no systematic reviews, let alone meta-analyses, of randomized controlled trials (RCTs) comparing tongxinluo capsule (TXL) and beta-blockers in treating angina pectoris. This study aimed to evaluate the efficacy of TXL and beta-blockers in treating angina pectoris by a meta-analysis of eligible RCTs. The RCTs comparing TXL with beta-blockers (including metoprolol) in treating angina pectoris were searched and retrieved from databases including PubMed, Chinese National Knowledge Infrastructure, and WanFang Data. Eligible RCTs were selected according to prespecified criteria. Meta-analysis was performed on the odds ratios (OR) of symptomatic and electrocardiographic (ECG) improvements after treatment. Subgroup analysis, sensitivity analysis, meta-regression, and publication biases analysis were conducted to evaluate the robustness of the results. Seventy-three RCTs published between 2000 and 2014 with 7424 participants were eligible. Overall ORs comparing TXL with beta-blockers were 3.40 (95% confidence interval [CI], 2.97-3.89; p<0.0001) for symptomatic improvement and 2.63 (95% CI, 2.29-3.02; p<0.0001) for ECG improvement. Subgroup analysis and sensitivity analysis found no statistically significant dependence of overall ORs on specific study characteristics except efficacy criteria. Meta-regression found no significant except sample sizes for data on symptomatic improvement. Publication biases were statistically significant. TXL seems to be more effective than beta-blockers in treating angina pectoris, on the basis of the eligible RCTs. Further RCTs are warranted to reduce publication bias and verify efficacy.
Pichai, Saravanan; Rajesh, M; Reddy, Naveen; Adusumilli, Gopinath; Reddy, Jayaprakash; Joshi, Bhavana
2014-09-01
Skeletal maturation is an integral part of individual pattern of growth and development and is a continuous process. Peak growth velocity in standing height is the most valid representation of the rate of overall skeletal growth. Ossification changes of hand wrist and cervical vertebrae are the reliable indicators of growth status of individual. The objective of this study was to compare skeletal maturation as measured by hand wrist bone analysis and cervical vertebral analysis. Hand wrist radiographs and lateral cephalograms of 72 subjects aged between 7 and 16 years both male and female from the patients visiting Department of Orthodontics and Dentofacial Orthopedics, R.V. Dental College and Hospital. The 9 stages were reduced to 5 stages to compare with cervical vertebral maturation stage by Baccetti et al. The Bjork, Grave and Brown stages were reduced to six intervals to compare with cervical vertebral maturational index (CVMI) staging by Hassel and Farman. These measurements were then compared with the hand wrist bone analysis, and the results were statistically analyzed using the Mann-Whitney test. There was no significant difference between the hand wrist analysis and the two different cervical vertebral analyses for assessing skeletal maturation. There was no significant difference between the two cervical vertebral analyses, but the CVMI method, which is visual method is less time consuming. Vertebral analysis on a lateral cephalogram is as valid as the hand wrist bone analysis with the advantage of reducing the radiation exposure of growing subjects.
Bending and stretching finite element analysis of anisotropic viscoelastic composite plates
NASA Technical Reports Server (NTRS)
Hilton, Harry H.; Yi, Sung
1990-01-01
Finite element algorithms have been developed to analyze linear anisotropic viscoelastic plates, with or without holes, subjected to mechanical (bending, tension), temperature, and hygrothermal loadings. The analysis is based on Laplace transforms rather than direct time integrations in order to improve the accuracy of the results and save on extensive computational time and storage. The time dependent displacement fields in the transverse direction for the cross ply and angle ply laminates are calculated and the stacking sequence effects of the laminates are discussed in detail. Creep responses for the plates with or without a circular hole are also studied. The numerical results compare favorably with analytical solutions, i.e. within 1.8 percent for bending and 10(exp -3) 3 percent for tension. The tension results of the present method are compared with those using the direct time integration scheme.
Failure of wooden sandwich beam reinforced with glass/epoxy faces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papakaliatakis, G. E.; Zacharopoulos, D. A.
2015-12-31
The mechanical properties and the failure of wooden beam strengthened with two faces from glass/epoxy composite and a wooden beam without strengthening was studied. Stresses and deflections on both beams, which are imposed in three point bending loading. On the idealized geometry of the specimens with detailed nonlinear orthotropic analysis was performed with a finite elements program. The failure study of the wooden beams was performed, applying the criterion of Tsai-Hill. The shear strength of the adhesive was taken into account. All the specimens were tested with three point bending loading and the experimental results were compared to those ofmore » the theoretical approach with the finite elements analysis. Comparing the results, the advantage of strengthened wooden beam against the simple wooden beam becomes obvious. Theoretical predictions were in good agreement with experimental results.« less
Analysis of the Effectiveness of F-15E Risk Management during Peacetime Operations
2015-06-18
of aircraft or life . These results were compared with existing risk management programs in the form of unit worksheet assessments. This study found...Force risk management program across all fixed-wing aircraft. Rotary wing aircraft will have their own unique challenges . However, for all its...the loss of aircraft or life . These results were compared with existing risk management programs in the form of unit worksheet assessments. This
Approximate Evaluation of Reliability and Availability via Perturbation Analysis.
1986-12-01
generating the dxact answers to which the results of the approximation will be compared are discussed:." - 87 7" 2 04 2LOISTRIGUTIONIAVAILASILITYI OF...appropriately, constructing the Markov process that approximately governs interclass behavior from the result above (this is called the enlarged... compared to a numerical or analytical computation of the aame quantities. This work and its continuation represents our progress so far on Goal 3. 2.4I
Hypnosis as an Adjunct to Cognitive-Behavioral Psychotherapy: A Meta-Analysis.
ERIC Educational Resources Information Center
Kirsch, Irving; And Others
1995-01-01
Performed a meta-analysis on 18 studies in which a cognitive-behavioral therapy was compared with the same therapy supplemented by hypnosis. Results indicated that hypnosis substantially enhanced treatment outcome, even though there were few procedural differences between the hypnotic and nonhypnotic treatments. Effects seemed particularly…
An Inexpensive Electrodeposition Device and Its Use in a Quantitative Analysis Laboratory Exercise
ERIC Educational Resources Information Center
Parker, Richard H.
2011-01-01
An experimental procedure, using an apparatus that is easy to construct, was developed to incorporate a quantitative electrogravimetric determination of the solution nickel content into an undergraduate or advanced high school quantitative analysis laboratory. This procedure produces results comparable to the procedure used for the gravimetric…
Icons as Visual Forum of Knowledge Representation on the World Wide Web: A Semiotic Analysis.
ERIC Educational Resources Information Center
Ma, Yan; Diodato, Virgil
1999-01-01
Compares the indexing structure of icons with principles used for traditional indexing. A sample of 15 library homepages was drawn from the total population of the United States library homepages. Semiotics theory was used to study the icons. Analysis and results are outlined. (AEF)
On the Utility of Content Analysis in Author Attribution: "The Federalist."
ERIC Educational Resources Information Center
Martindale, Colin; McKenzie, Dean
1995-01-01
Compares the success of lexical statistics, content analysis, and function words in determining the true author of "The Federalist." The function word approach proved most successful in attributing the papers to James Madison. Lexical statistics contributed nothing, while content analytic measures resulted in some success. (MJP)
Finite Volume Element (FVE) discretization and multilevel solution of the axisymmetric heat equation
NASA Astrophysics Data System (ADS)
Litaker, Eric T.
1994-12-01
The axisymmetric heat equation, resulting from a point-source of heat applied to a metal block, is solved numerically; both iterative and multilevel solutions are computed in order to compare the two processes. The continuum problem is discretized in two stages: finite differences are used to discretize the time derivatives, resulting is a fully implicit backward time-stepping scheme, and the Finite Volume Element (FVE) method is used to discretize the spatial derivatives. The application of the FVE method to a problem in cylindrical coordinates is new, and results in stencils which are analyzed extensively. Several iteration schemes are considered, including both Jacobi and Gauss-Seidel; a thorough analysis of these schemes is done, using both the spectral radii of the iteration matrices and local mode analysis. Using this discretization, a Gauss-Seidel relaxation scheme is used to solve the heat equation iteratively. A multilevel solution process is then constructed, including the development of intergrid transfer and coarse grid operators. Local mode analysis is performed on the components of the amplification matrix, resulting in the two-level convergence factors for various combinations of the operators. A multilevel solution process is implemented by using multigrid V-cycles; the iterative and multilevel results are compared and discussed in detail. The computational savings resulting from the multilevel process are then discussed.
Independent Orbiter Assessment (IOA): Assessment of the active thermal control system
NASA Technical Reports Server (NTRS)
Sinclair, S. K.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Active Thermal Control System (ATCS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the available NASA FMEA/CIL data. Discrepancies from the comparison were documented, and where enough information was available, recommendations for resolution of the discrepancies were made. This report documents the results of that comparison for the Orbiter ATCS hardware. The IOA product for the ATCS independent analysis consisted of 310 failure mode worksheets that resulted in 101 potential critical items (PCI) being identified. A comparison was made to the available NASA data which consisted of 252 FMEAs and 109 CIL items.
Karyotype versus microarray testing for genetic abnormalities after stillbirth.
Reddy, Uma M; Page, Grier P; Saade, George R; Silver, Robert M; Thorsten, Vanessa R; Parker, Corette B; Pinar, Halit; Willinger, Marian; Stoll, Barbara J; Heim-Hall, Josefine; Varner, Michael W; Goldenberg, Robert L; Bukowski, Radek; Wapner, Ronald J; Drews-Botsch, Carolyn D; O'Brien, Barbara M; Dudley, Donald J; Levy, Brynn
2012-12-06
Genetic abnormalities have been associated with 6 to 13% of stillbirths, but the true prevalence may be higher. Unlike karyotype analysis, microarray analysis does not require live cells, and it detects small deletions and duplications called copy-number variants. The Stillbirth Collaborative Research Network conducted a population-based study of stillbirth in five geographic catchment areas. Standardized postmortem examinations and karyotype analyses were performed. A single-nucleotide polymorphism array was used to detect copy-number variants of at least 500 kb in placental or fetal tissue. Variants that were not identified in any of three databases of apparently unaffected persons were then classified into three groups: probably benign, clinical significance unknown, or pathogenic. We compared the results of karyotype and microarray analyses of samples obtained after delivery. In our analysis of samples from 532 stillbirths, microarray analysis yielded results more often than did karyotype analysis (87.4% vs. 70.5%, P<0.001) and provided better detection of genetic abnormalities (aneuploidy or pathogenic copy-number variants, 8.3% vs. 5.8%; P=0.007). Microarray analysis also identified more genetic abnormalities among 443 antepartum stillbirths (8.8% vs. 6.5%, P=0.02) and 67 stillbirths with congenital anomalies (29.9% vs. 19.4%, P=0.008). As compared with karyotype analysis, microarray analysis provided a relative increase in the diagnosis of genetic abnormalities of 41.9% in all stillbirths, 34.5% in antepartum stillbirths, and 53.8% in stillbirths with anomalies. Microarray analysis is more likely than karyotype analysis to provide a genetic diagnosis, primarily because of its success with nonviable tissue, and is especially valuable in analyses of stillbirths with congenital anomalies or in cases in which karyotype results cannot be obtained. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development.).
Andriolo, Luca; Merli, Giulia; Tobar, Carlos; Altamura, Sante Alessandro; Kon, Elizaveta; Filardo, Giuseppe
2018-02-06
The aim of this study was to document the available evidence on the use of regenerative techniques for the treatment of femoral head osteonecrosis (or avascular necrosis of femoral head, AVN) and to understand their benefit compared to core decompression (CD) alone in avoiding failure and the need for total hip replacement (THR). The search was conducted on three medical electronic databases according to PRISMA guidelines. The studies reporting number and timing of failures were included in a meta-analysis calculating cumulative survivorship with a Kaplan-Mayer curve. Moreover, the results on failures in treatment groups reported in RCT were compared with those documented in control groups, in order to understand the benefit of biological therapies compared to CD for the treatment of AVN. Forty-eight studies were included in this systematic review, reporting results of different types of regenerative techniques: mesenchymal stem cell implantation in the osteonecrotic area, intra-arterial infiltration with mesenchymal stem cells, implantation of bioactive molecules, or platelet-rich plasma. Overall, reported results were good, with a cumulative survivorship of 80% after ten year follow-up, and better results when regenerative treatments were combined to CD compared to CD alone (89.9% vs 70.6%, p < 0.0001). Regenerative therapies offer good clinical results for the treatment of AVN. The combination of CD with regenerative techniques provides a significant improvement in terms of survivorship over time compared with CD alone. Further studies are needed to identify the best procedure and the most suitable patients to benefit from regenerative treatments for AVN.
Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.
2014-01-01
Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643
NASA Technical Reports Server (NTRS)
Orifici, Adrian C.; Krueger, Ronald
2010-01-01
With capabilities for simulating delamination growth in composite materials becoming available, the need for benchmarking and assessing these capabilities is critical. In this study, benchmark analyses were performed to assess the delamination propagation simulation capabilities of the VCCT implementations in Marc TM and MD NastranTM. Benchmark delamination growth results for Double Cantilever Beam, Single Leg Bending and End Notched Flexure specimens were generated using a numerical approach. This numerical approach was developed previously, and involves comparing results from a series of analyses at different delamination lengths to a single analysis with automatic crack propagation. Specimens were analyzed with three-dimensional and two-dimensional models, and compared with previous analyses using Abaqus . The results demonstrated that the VCCT implementation in Marc TM and MD Nastran(TradeMark) was capable of accurately replicating the benchmark delamination growth results and that the use of the numerical benchmarks offers advantages over benchmarking using experimental and analytical results.
Independent Orbiter Assessment (IOA): Assessment of the remote manipulator system FMEA/CIL
NASA Technical Reports Server (NTRS)
Tangorra, F.; Grasmeder, R. F.; Montgomery, A. D.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Remote Manipulator System (RMS) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were than compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter RMS hardware are documented. The IOA product for the RMS analysis consisted of 604 failure mode worksheets that resulted in 458 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 45 FMEAs and 321 CIL items. This comparison produced agreement on all but 154 FMEAs which caused differences in 137 CIL items.
NASA Astrophysics Data System (ADS)
Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho
2013-10-01
Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0-10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700-5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods.
Independent Orbiter Assessment (IOA): Assessment of the hydraulics/water spray boiler subsystem
NASA Technical Reports Server (NTRS)
Bynum, M. C.; Duval, J. D.; Parkman, W. E.; Davidson, W. R.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Hydraulics/Water Spray Boiler (HYD/WSB) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter HYD/WSB hardware. The IOA product for the HYD/WSB analysis consisted of 447 failure mode worksheets that resulted in 183 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 364 FMEAs and 111 CIL items. This comparison produced agreement on all but 68 FMEAs which caused differences in 23 CIL items.
NASA Technical Reports Server (NTRS)
Mccants, C. N.; Bearrow, M.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Electrical Power Distribution and Control/Electrical Power Generation (EPD and C/EPG) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison was provided through additional analysis as required. The results of that comparison is documented for the Orbiter EPD and C/EPG hardware. The IOA product for the EPD and C/EPG analysis consisted of 263 failure mode worksheets that resulted in 42 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 211 FMEA and 47 CIL items.
Independent Orbiter Assessment (IOA): Assessment of the auxiliary power unit
NASA Technical Reports Server (NTRS)
Barnes, J. E.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Auxiliary Power Unit (APU) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter APU hardware. The IOA product for the APU analysis, covering both APU hardware and APU electrical components, consisted of 344 failure mode worksheets that resulted in 178 potential critical items being identified. A comparison was made of the IOA product to the NASA APU hardware FMEA/CIL baseline which consisted of 184 FMEAs and 57 CIL items. The comparison identified 72 discrepancies.
NASA Technical Reports Server (NTRS)
Trahan, W. H.; Odonnell, R. A.; Pietz, K. C.; Drapela, L. J.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Guidance, Navigation, and Control System (GNC) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter GNC hardware is documented. The IOA product for the GNC analysis consisted of 141 failure mode worksheets that resulted in 24 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 148 FMEAs and 36 CIL items. This comparison produced agreement on all but 56 FMEAs which caused differences in zero CIL items.
Independent Orbiter Assessment (IOA): Assessment of the body flap subsystem FMEA/CIL
NASA Technical Reports Server (NTRS)
Wilson, R. E.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Body Flap (BF) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter BF hardware. The IOA product for the BF analysis consisted of 43 failure mode worksheets that resulted in 19 potential critical items being identified. Comparison was made to the NASA baseline which consisted of 34 FMEAs and 15 CIL items. This comparison produced agreement on all CIL items. Based on the Pre 51-L baseline, all non-CIL FMEAs were also in agreement.
Independent Orbiter Assessment (IOA): Assessment of the elevon actuator subsystem FMEA/CIL
NASA Technical Reports Server (NTRS)
Wilson, R. E.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Elevon Subsystem hardware, generating draft failure modes, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter Elevon hardware. The IOA product for the Elevon analysis consisted of 25 failure mode worksheets that resulted in 17 potential critical items being identified. Comparison was made to the NASA FMEA/CIL, which consisted of 23 FMEAs and 13 CIL items. This comparison produced agreement on all CIL items. Based on the Pre 51-L baseline, all non-CIL FMEAs were also in agreement.
Karahalios, Amalia Emily; Salanti, Georgia; Turner, Simon L; Herbison, G Peter; White, Ian R; Veroniki, Areti Angeliki; Nikolakopoulou, Adriani; Mckenzie, Joanne E
2017-06-24
Network meta-analysis, a method to synthesise evidence from multiple treatments, has increased in popularity in the past decade. Two broad approaches are available to synthesise data across networks, namely, arm- and contrast-synthesis models, with a range of models that can be fitted within each. There has been recent debate about the validity of the arm-synthesis models, but to date, there has been limited empirical evaluation comparing results using the methods applied to a large number of networks. We aim to address this gap through the re-analysis of a large cohort of published networks of interventions using a range of network meta-analysis methods. We will include a subset of networks from a database of network meta-analyses of randomised trials that have been identified and curated from the published literature. The subset of networks will include those where the primary outcome is binary, the number of events and participants are reported for each direct comparison, and there is no evidence of inconsistency in the network. We will re-analyse the networks using three contrast-synthesis methods and two arm-synthesis methods. We will compare the estimated treatment effects, their standard errors, treatment hierarchy based on the surface under the cumulative ranking (SUCRA) curve, the SUCRA value, and the between-trial heterogeneity variance across the network meta-analysis methods. We will investigate whether differences in the results are affected by network characteristics and baseline risk. The results of this study will inform whether, in practice, the choice of network meta-analysis method matters, and if it does, in what situations differences in the results between methods might arise. The results from this research might also inform future simulation studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rioja, María J.; Dodson, Richard; Jung, TaeHyun
The Korean VLBI Network (KVN) is a new millimeter VLBI dedicated array with the capability to simultaneously observe at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well-established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in 2013 April. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switchingmore » observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in superior compensation for all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts, and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low-resolution effects for extended sources in the astrometric measurements. The results from the analysis of the KVN and full VLBA data sets agree within 2σ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1σ, when compared to a VLBA configuration that has a similar resolution. Therefore, this comparative study verifies the astrometric performance of the KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.« less
Independent Orbiter Assessment (IOA): Assessment of the purge, vent and drain subsystem
NASA Technical Reports Server (NTRS)
Bynum, M. C., III
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Purge, Vent and Drain (PV and D) hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter PV and D hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET disconnect.
Malucelli, Emil; Procopio, Alessandra; Fratini, Michela; Gianoncelli, Alessandra; Notargiacomo, Andrea; Merolle, Lucia; Sargenti, Azzurra; Castiglioni, Sara; Cappadone, Concettina; Farruggia, Giovanna; Lombardo, Marco; Lagomarsino, Stefano; Maier, Jeanette A; Iotti, Stefano
2018-01-01
The quantification of elemental concentration in cells is usually performed by analytical assays on large populations missing peculiar but important rare cells. The present article aims at comparing the elemental quantification in single cells and cell population in three different cell types using a new approach for single cells elemental analysis performed at sub-micrometer scale combining X-ray fluorescence microscopy and atomic force microscopy. The attention is focused on the light element Mg, exploiting the opportunity to compare the single cell quantification to the cell population analysis carried out by a highly Mg-selective fluorescent chemosensor. The results show that the single cell analysis reveals the same Mg differences found in large population of the different cell strains studied. However, in one of the cell strains, single cell analysis reveals two cells with an exceptionally high intracellular Mg content compared with the other cells of the same strain. The single cell analysis allows mapping Mg and other light elements in whole cells at sub-micrometer scale. A detailed intensity correlation analysis on the two cells with the highest Mg content reveals that Mg subcellular localization correlates with oxygen in a different fashion with respect the other sister cells of the same strain. Graphical abstract Single cells or large population analysis this is the question!
Development of an integrated aeroservoelastic analysis program and correlation with test data
NASA Technical Reports Server (NTRS)
Gupta, K. K.; Brenner, M. J.; Voelker, L. S.
1991-01-01
The details and results are presented of the general-purpose finite element STructural Analysis RoutineS (STARS) to perform a complete linear aeroelastic and aeroservoelastic analysis. The earlier version of the STARS computer program enabled effective finite element modeling as well as static, vibration, buckling, and dynamic response of damped and undamped systems, including those with pre-stressed and spinning structures. Additions to the STARS program include aeroelastic modeling for flutter and divergence solutions, and hybrid control system augmentation for aeroservoelastic analysis. Numerical results of the X-29A aircraft pertaining to vibration, flutter-divergence, and open- and closed-loop aeroservoelastic controls analysis are compared to ground vibration, wind-tunnel, and flight-test results. The open- and closed-loop aeroservoelastic control analyses are based on a hybrid formulation representing the interaction of structural, aerodynamic, and flight-control dynamics.
Wang, D Z; Wang, C; Shen, C F; Zhang, Y; Zhang, H; Song, G D; Xue, X D; Xu, Z L; Zhang, S; Jiang, G H
2017-05-10
We described the time trend of acute myocardial infarction (AMI) from 1999 to 2013 in Tianjin incidence rate with Cochran-Armitage trend (CAT) test and linear regression analysis, and the results were compared. Based on actual population, CAT test had much stronger statistical power than linear regression analysis for both overall incidence trend and age specific incidence trend (Cochran-Armitage trend P value
Alsaqa'aby, Mai F; Vaidya, Varun; Khreis, Noura; Khairallah, Thamer Al; Al-Jedai, Ahmed H
2017-01-01
Promising clinical and humanistic outcomes are associated with the use of new oral agents in the treatment of relapsing-remitting multiple sclerosis (RRMS). This is the first cost-effectiveness study comparing these medications in Saudi Arabia. We aimed to compare the cost-effectiveness of fingolimod, teriflunomide, dimethyl fumarate, and interferon (IFN)-b1a products (Avonex and Rebif) as first-line therapies in the treatment of patients with RRMS from a Saudi payer perspective. Cohort Simulation Model (Markov Model). Tertiary care hospital. A hypothetical cohort of 1000 RRMS Saudi patients was assumed to enter a Markov model model with a time horizon of 20 years and an annual cycle length. The model was developed based on an expanded disability status scale (EDSS) to evaluate the cost-effectiveness of the five disease-modifying drugs (DMDs) from a healthcare system perspective. Data on EDSS progression and relapse rates were obtained from the literature; cost data were obtained from King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia. Results were expressed as incremental cost-effectiveness ratios (ICERs) and net monetary benefits (NMB) in Saudi Riyals and converted to equivalent $US. The base-case willingness-to-pay (WTP) threshold was assumed to be $100000 (SAR375000). One-way sensitivity analysis and probabilistic sensitivity analysis were conducted to test the robustness of the model. ICERs and NMB. The base-case analysis results showed Rebif as the optimal therapy at a WTP threshold of $100000. Avonex had the lowest ICER value of $337282/QALY when compared to Rebif. One-way sensitivity analysis demonstrated that the results were sensitive to utility weights of health state three and four and the cost of Rebif. None of the DMDs were found to be cost-effective in the treatment of RRMS at a WTP threshold of $100000 in this analysis. The DMDs would only be cost-effective at a WTP above $300000. The current analysis did not reflect the Saudi population preference in valuation of health states and did not consider the societal perspective in terms of cost.
Noise studies of communication systems using the SYSTID computer aided analysis program
NASA Technical Reports Server (NTRS)
Tranter, W. H.; Dawson, C. T.
1973-01-01
SYSTID computer aided design is a simple program for simulating data systems and communication links. A trial of the efficiency of the method was carried out by simulating a linear analog communication system to determine its noise performance and by comparing the SYSTID result with the result arrived at by theoretical calculation. It is shown that the SYSTID program is readily applicable to the analysis of these types of systems.
ERIC Educational Resources Information Center
Indefrey, Peter
2006-01-01
This article presents the results of a meta-analysis of 30 hemodynamic experiments comparing first language (L1) and second language (L2) processing in a range of tasks. The results suggest that reliably stronger activation during L2 processing is found (a) only for task-specific subgroups of L2 speakers and (b) within some, but not all regions…
Thermodynamic Cycle and CFD Analyses for Hydrogen Fueled Air-breathing Pulse Detonation Engines
NASA Technical Reports Server (NTRS)
Povinelli, Louis A.; Yungster, Shaye
2002-01-01
This paper presents the results of a thermodynamic cycle analysis of a pulse detonation engine (PDE) using a hydrogen-air mixture at static conditions. The cycle performance results, namely the specific thrust, fuel consumption and impulse are compared to a single cycle CFD analysis for a detonation tube which considers finite rate chemistry. The differences in the impulse values were indicative of the additional performance potential attainable in a PDE.
An Integrated Tool for System Analysis of Sample Return Vehicles
NASA Technical Reports Server (NTRS)
Samareh, Jamshid A.; Maddock, Robert W.; Winski, Richard G.
2012-01-01
The next important step in space exploration is the return of sample materials from extraterrestrial locations to Earth for analysis. Most mission concepts that return sample material to Earth share one common element: an Earth entry vehicle. The analysis and design of entry vehicles is multidisciplinary in nature, requiring the application of mass sizing, flight mechanics, aerodynamics, aerothermodynamics, thermal analysis, structural analysis, and impact analysis tools. Integration of a multidisciplinary problem is a challenging task; the execution process and data transfer among disciplines should be automated and consistent. This paper describes an integrated analysis tool for the design and sizing of an Earth entry vehicle. The current tool includes the following disciplines: mass sizing, flight mechanics, aerodynamics, aerothermodynamics, and impact analysis tools. Python and Java languages are used for integration. Results are presented and compared with the results from previous studies.
NASA Astrophysics Data System (ADS)
Federico, S.; Avolio, E.; Bellecci, C.; Colacino, M.; Walko, R. L.
2006-03-01
This paper reports preliminary results for a Limited area model Ensemble Prediction System (LEPS), based on RAMS (Regional Atmospheric Modelling System), for eight case studies of moderate-intense precipitation over Calabria, the southernmost tip of the Italian peninsula. LEPS aims to transfer the benefits of a probabilistic forecast from global to regional scales in countries where local orographic forcing is a key factor to force convection. To accomplish this task and to limit computational time in an operational implementation of LEPS, we perform a cluster analysis of ECMWF-EPS runs. Starting from the 51 members that form the ECMWF-EPS we generate five clusters. For each cluster a representative member is selected and used to provide initial and dynamic boundary conditions to RAMS, whose integrations generate LEPS. RAMS runs have 12-km horizontal resolution. To analyze the impact of enhanced horizontal resolution on quantitative precipitation forecasts, LEPS forecasts are compared to a full Brute Force (BF) ensemble. This ensemble is based on RAMS, has 36 km horizontal resolution and is generated by 51 members, nested in each ECMWF-EPS member. LEPS and BF results are compared subjectively and by objective scores. Subjective analysis is based on precipitation and probability maps of case studies whereas objective analysis is made by deterministic and probabilistic scores. Scores and maps are calculated by comparing ensemble precipitation forecasts against reports from the Calabria regional raingauge network. Results show that LEPS provided better rainfall predictions than BF for all case studies selected. This strongly suggests the importance of the enhanced horizontal resolution, compared to ensemble population, for Calabria for these cases. To further explore the impact of local physiographic features on QPF (Quantitative Precipitation Forecasting), LEPS results are also compared with a 6-km horizontal resolution deterministic forecast. Due to local and mesoscale forcing, the high resolution forecast (Hi-Res) has better performance compared to the ensemble mean for rainfall thresholds larger than 10mm but it tends to overestimate precipitation for lower amounts. This yields larger false alarms that have a detrimental effect on objective scores for lower thresholds. To exploit the advantages of a probabilistic forecast compared to a deterministic one, the relation between the ECMWF-EPS 700 hPa geopotential height spread and LEPS performance is analyzed. Results are promising even if additional studies are required.
The October 1973 NASA mission model analysis and economic assessment
NASA Technical Reports Server (NTRS)
1974-01-01
Results are presented of the 1973 NASA Mission Model Analysis. The purpose was to obtain an economic assessment of using the Shuttle to accommodate the payloads and requirements as identified by the NASA Program Offices and the DoD. The 1973 Payload Model represents a baseline candidate set of future payloads which can be used as a reference base for planning purposes. The cost of implementing these payload programs utilizing the capabilities of the shuttle system is analyzed and compared with the cost of conducting the same payload effort using expendable launch vehicles. There is a net benefit of 14.1 billion dollars as a result of using the shuttle during the 12-year period as compared to using an expendable launch vehicle fleet.
Coppens, Patrick; Hungerford, Suzanne; Yamaguchi, Satoshi; Yamadori, Atsushi
2002-12-01
This study presents a thorough analysis of published crossed aphasia (CA) cases, including for the first time the cases published in Japanese. The frequency of specific symptoms was determined, and symptomatology differences based on gender, familial sinistrality, and CA subtype were investigated. Results suggested that the CA population is comparable to the left-hemisphere patient population. However, male were significantly more likely than female CA subjects to show a positive history of familial sinistrality. Typical right-hemisphere (i.e., nonlanguage-dominant) symptoms were frequent but rarely carefully reported or assessed. Results are compared with previous CA reviews and left-hemisphere aphasia. Suggestions for a more systematic assessment of the CA symptomatology are presented.
Design and Optimization of Composite Gyroscope Momentum Wheel Rings
NASA Technical Reports Server (NTRS)
Bednarcyk, Brett A.; Arnold, Steven M.
2007-01-01
Stress analysis and preliminary design/optimization procedures are presented for gyroscope momentum wheel rings composed of metallic, metal matrix composite, and polymer matrix composite materials. The design of these components involves simultaneously minimizing both true part volume and mass, while maximizing angular momentum. The stress analysis results are combined with an anisotropic failure criterion to formulate a new sizing procedure that provides considerable insight into the design of gyroscope momentum wheel ring components. Results compare the performance of two optimized metallic designs, an optimized SiC/Ti composite design, and an optimized graphite/epoxy composite design. The graphite/epoxy design appears to be far superior to the competitors considered unless a much greater premium is placed on volume efficiency compared to mass efficiency.
Brooks, Myron H.; Schroder, LeRoy J.; Willoughby, Timothy C.
1987-01-01
Four laboratories involved in the routine analysis of wet-deposition samples participated in an interlaboratory comparison program managed by the U.S. Geological Survey. The four participants were: Illinois State Water Survey central analytical laboratory in Champaign, Illinois; U.S. Geological Survey national water-quality laboratories in Atlanta, Georgia, and Denver, Colorado; and Inland Waters Directorate national water-quality laboratory in Burlington, Ontario, Canada. Analyses of interlaboratory samples performed by the four laboratories from October 1983 through December 1984 were compared.Participating laboratories analyzed three types of interlaboratory samples--natural wet deposition, simulated wet deposition, and deionized water--for pH and specific conductance, and for dissolved calcium, magnesium, sodium, sodium, potassium, chloride, sulfate, nitrate, ammonium, and orthophosphate. Natural wet-deposition samples were aliquots of actual wet-deposition samples. Analyses of these samples by the four laboratories were compared using analysis of variance. Test results indicated that pH, calcium, nitrate, and ammonium results were not directly comparable among the four laboratories. Statistically significant differences between laboratory results probably only were meaningful for analyses of dissolved calcium. Simulated wet-deposition samples with known analyte concentrations were used to test each laboratory for analyte bias. Laboratory analyses of calcium, magnesium, sodium, potassium, chloride, sulfate, and nitrate were not significantly different from the known concentrations of these analytes when tested using analysis of variance. Deionized-water samples were used to test each laboratory for reporting of false positive values. The Illinois State Water Survey Laboratory reported the smallest percentage of false positive values for most analytes. Analyte precision was estimated for each laboratory from results of replicate measurements. In general, the Illinois State Water Survey laboratory achieved the greatest precision, whereas the U.S. Geological Survey laboratories achieved the least precision.
De Silva, Veronica; Oldham, Charlie D; May, Sheldon W
2010-09-01
Phenylketonuria (PKU) is an autosomal recessive disorder caused by an impaired conversion of L-phenylalanine (Phe) to L-tyrosine, typically resulting from a deficiency in activity of a hepatic and renal enzyme L-phenylalanine hydroxylase. The disease is characterized by an increased concentration of Phe and its metabolites in body fluids. A modified assay based on an enzymatic-colorimetric methodology was developed for measuring blood Phe levels in PKU patients; this method is designed for use with undeproteinized samples and avoids the use of solvents or amphiphilic agents. Thus, the method could be suitable for incorporation into a simple home-monitoring device. We report here on a comparison of blood Phe concentrations in PKU patients measured in undeproteinized plasma using this enzyme colorimetric assay (ECA), with values determined by amino acid analysis (AAA) of deproteinized samples, and HPLC and tandem mass spectrometry (MS/MS) analyses of dried blood spot (DBS) eluates. Pearson correlation coefficients of 0.951, 0.976 and 0.988 were obtained when AAA-measured Phe concentrations were compared with the ECA-, HPLC- or MS/MS-measured values, respectively. A Bland-Altman analysis revealed that mean Phe concentrations determined using AAA were on average 65 μmol/L lower than values measured by our ECA. These results may be the result of minimizing the manipulations performed on the patient sample compared with AAA, HPLC, and MS/MS methods, which involve plasma deproteinization or DBS elution and derivatization. The results reported here confirm that Phe concentrations determined by our ECA method are comparable to those determined by other widely used methods for a broad range of plasma Phe concentrations.
Functional outcomes in African-Americans after robot-assisted radical prostatectomy.
DeCastro, G Joel; Jayram, Gautam; Razmaria, Aria; Shalhav, Arieh; Zagaja, Gregory P
2012-08-01
Previous studies have demonstrated differences in surgical outcomes after radical prostatectomy based on ethnicity. We compared sexual and urinary outcomes in African-American (AA) patients 6 and 12 months after robot-assisted radical prostatectomy (RARP) with those of non-AA patients. We reviewed our RARP database at our institution for patients with at least 12 months of follow-up. Erectile function was defined using the University of California, Los Angeles Prostate Cancer Index as erections "firm enough for masturbation and foreplay" or "firm enough for intercourse," while urinary continence was defined as being "pad free." Only patients who were potent and pad free preoperatively were included in the analysis. Multivariate logistic regression was used to compare postoperative potency and urinary pad-free status between AA and non-AA patients while controlling for pertinent demographic, clinical, and pathologic variables. In the urinary continence analysis, 140 AA patients and 576 non-AA patients were included, compared with 105 AAs and 500 non-AA patients who were included in the analysis of sexual function. At 12 months postoperatively, a smaller proportion of AA patients were potent compared with non-AA patients (60% vs 76.4%, P=0.001). Similarly, we found a lower incidence of pad-free status for AA patients at 12 months postoperatively (55.7% vs 69.8%, P=0.039). Similar functional results were found at 6 months postoperatively for both analysis groups. AA men appear to have worse urinary and sexual outcomes at 12 months after RARP compared with non-AA patients. At 6 months, there is no statistically significant difference. Further, longer-term studies are needed to validate these results.
NASA Technical Reports Server (NTRS)
Grosveld, Ferdinand W.; Schiller, Noah H.; Cabell, Randolph H.
2011-01-01
Comet Enflow is a commercially available, high frequency vibroacoustic analysis software founded on Energy Finite Element Analysis (EFEA) and Energy Boundary Element Analysis (EBEA). Energy Finite Element Analysis (EFEA) was validated on a floor-equipped composite cylinder by comparing EFEA vibroacoustic response predictions with Statistical Energy Analysis (SEA) and experimental results. Statistical Energy Analysis (SEA) predictions were made using the commercial software program VA One 2009 from ESI Group. The frequency region of interest for this study covers the one-third octave bands with center frequencies from 100 Hz to 4000 Hz.
Emotional loneliness in sexual murderers: a qualitative analysis.
Milsom, Jacci; Beech, Anthony R; Webster, Stephen D
2003-10-01
This study compared levels of emotional loneliness between sexual murderers and rapists who had not gone on to kill their victim/s. All participants were life-sentenced prisoners in the United Kingdom. Assessment consisted of a semistructured interview and was subjected to grounded theory analysis. This approach is defined as the breaking down, naming, comparing, and categorizing of data. As such, it is distinguished from other qualitative methods by the process of constant comparison. This continual sifting and comparing elements assists in promoting conceptual and theoretical development. The results of this process found that sexual murderers, compared to rapists, reported significantly higher levels of grievance towards females in childhood, significantly higher levels of peer group loneliness in adolescence, and significantly higher levels of self as victim in adulthood.
Hartmann, Luise; Stephenson, Christine F; Verkamp, Stephanie R; Johnson, Krystal R; Burnworth, Bettina; Hammock, Kelle; Brodersen, Lisa Eidenschink; de Baca, Monica E; Wells, Denise A; Loken, Michael R; Zehentner, Barbara K
2014-12-01
Array comparative genomic hybridization (aCGH) has become a powerful tool for analyzing hematopoietic neoplasms and identifying genome-wide copy number changes in a single assay. aCGH also has superior resolution compared with fluorescence in situ hybridization (FISH) or conventional cytogenetics. Integration of single nucleotide polymorphism (SNP) probes with microarray analysis allows additional identification of acquired uniparental disomy, a copy neutral aberration with known potential to contribute to tumor pathogenesis. However, a limitation of microarray analysis has been the inability to detect clonal heterogeneity in a sample. This study comprised 16 samples (acute myeloid leukemia, myelodysplastic syndrome, chronic lymphocytic leukemia, plasma cell neoplasm) with complex cytogenetic features and evidence of clonal evolution. We used an integrated manual peak reassignment approach combining analysis of aCGH and SNP microarray data for characterization of subclonal abnormalities. We compared array findings with results obtained from conventional cytogenetic and FISH studies. Clonal heterogeneity was detected in 13 of 16 samples by microarray on the basis of log2 values. Use of the manual peak reassignment analysis approach improved resolution of the sample's clonal composition and genetic heterogeneity in 10 of 13 (77%) patients. Moreover, in 3 patients, clonal disease progression was revealed by array analysis that was not evident by cytogenetic or FISH studies. Genetic abnormalities originating from separate clonal subpopulations can be identified and further characterized by combining aCGH and SNP hybridization results from 1 integrated microarray chip by use of the manual peak reassignment technique. Its clinical utility in comparison to conventional cytogenetic or FISH studies is demonstrated. © 2014 American Association for Clinical Chemistry.
Snauwaert, Isabel; Stragier, Pieter; De Vuyst, Luc; Vandamme, Peter
2015-04-03
Pediococcus damnosus LMG 28219 is a lactic acid bacterium dominating the maturation phase of Flemish acid beer productions. It proved to be capable of growing in beer, thereby resisting this environment, which is unfavorable for microbial growth. The molecular mechanisms underlying its metabolic capabilities and niche adaptations were unknown up to now. In the present study, whole-genome sequencing and comparative genome analysis were used to investigate this strain's mechanisms to reside in the beer niche, with special focus on not only stress and hop resistances but also folate biosynthesis and exopolysaccharide (EPS) production. The draft genome sequence of P. damnosus LMG 28219 harbored 183 contigs, including an intact prophage region and several coding sequences involved in plasmid replication. The annotation of 2178 coding sequences revealed the presence of many transporters and transcriptional regulators and several genes involved in oxidative stress response, hop resistance, de novo folate biosynthesis, and EPS production. Comparative genome analysis of P. damnosus LMG 28219 with Pediococcus claussenii ATCC BAA-344(T) (beer origin) and Pediococcus pentosaceus ATCC 25745 (plant origin) revealed that various hop resistance genes and genes involved in de novo folate biosynthesis were unique to the strains isolated from beer. This contrasted with the genes related to osmotic stress responses, which were shared between the strains compared. Furthermore, transcriptional regulators were enriched in the genomes of bacteria capable of growth in beer, suggesting that those cause rapid up- or down-regulation of gene expression. Genome sequence analysis of P. damnosus LMG 28219 provided insights into the underlying mechanisms of its adaptation to the beer niche. The results presented will enable analysis of the transcriptome and proteome of P. damnosus LMG 28219, which will result in additional knowledge on its metabolic activities.
2011-01-01
Background Meta-analysis is a popular methodology in several fields of medical research, including genetic association studies. However, the methods used for meta-analysis of association studies that report haplotypes have not been studied in detail. In this work, methods for performing meta-analysis of haplotype association studies are summarized, compared and presented in a unified framework along with an empirical evaluation of the literature. Results We present multivariate methods that use summary-based data as well as methods that use binary and count data in a generalized linear mixed model framework (logistic regression, multinomial regression and Poisson regression). The methods presented here avoid the inflation of the type I error rate that could be the result of the traditional approach of comparing a haplotype against the remaining ones, whereas, they can be fitted using standard software. Moreover, formal global tests are presented for assessing the statistical significance of the overall association. Although the methods presented here assume that the haplotypes are directly observed, they can be easily extended to allow for such an uncertainty by weighting the haplotypes by their probability. Conclusions An empirical evaluation of the published literature and a comparison against the meta-analyses that use single nucleotide polymorphisms, suggests that the studies reporting meta-analysis of haplotypes contain approximately half of the included studies and produce significant results twice more often. We show that this excess of statistically significant results, stems from the sub-optimal method of analysis used and, in approximately half of the cases, the statistical significance is refuted if the data are properly re-analyzed. Illustrative examples of code are given in Stata and it is anticipated that the methods developed in this work will be widely applied in the meta-analysis of haplotype association studies. PMID:21247440
He, Jian; Wu, Ping; Tang, Yaoyun; Liu, Sulai; Xie, Chubo; Luo, Shi; Zeng, Junfeng; Xu, Jing; Zhao, Suping
2017-01-01
Object A Bayesian network meta-analysis (NMA) was conducted to estimate the overall survival (OS) and complete response (CR) performance in nasopharyngeal carcinoma (NPC) patients who have been given the treatment of radiotherapy, concurrent chemoradiotherapy (C), adjuvant chemotherapy (A), neoadjuvant chemotherapy (N), concurrent chemoradiotherapy with adjuvant chemotherapy (C+A), concurrent chemoradiotherapy with neoadjuvant chemotherapy (C+N) and neoadjuvant chemotherapy with adjuvant chemotherapy (N+A). Methods Literature search was conducted in electronic databases. Hazard ratios (HRs) accompanied their 95% confidence intervals (95%CIs) or 95% credible intervals (95%CrIs) were applied to measure the relative survival benefit between two comparators. Meanwhile odd ratios (ORs) with their 95% CIs or CrIs were given to present CR data from individual studies. RESULTS Totally 52 qualified studies with 10,081 patients were included in this NMA. In conventional meta-analysis (MA), patients with N+C exhibited an average increase of 9% in the 3-year OS in relation to those with C+A. As for the NMA results, five therapies were associated with a significantly reduced HR when compared with the control group when concerning 5-year OS. C, C+A and N+A also presented a decreased HR compared with A. There was continuity among 1-year, 3-year and 5-year OS status. Cluster analysis suggested that the three chemoradiotherapy appeared to be divided into the most compete group which is located in the upper right corner of the cluster plot. Conclusion In view of survival rate and complete response, the NMA results revealed that C, C+A and C+N showed excellent efficacy. As a result, these 3 therapies were supposed to be considered as the first-line treatment according to this NMA. PMID:28418901
Rasch analysis of the Edmonton Symptom Assessment System and research implications.
Cheifetz, O; Packham, T L; Macdermid, J C
2014-04-01
Reliable and valid assessment of the disease burden across all forms of cancer is critical to the evaluation of treatment effectiveness and patient progress. The Edmonton Symptom Assessment System (esas) is used for routine evaluation of people attending for cancer care. In the present study, we used Rasch analysis to explore the measurement properties of the esas and to determine the effect of using Rasch-proposed interval-level esas scoring compared with traditional scoring when evaluating the effects of an exercise program for cancer survivors. Polytomous Rasch analysis (Andrich's rating-scale model) was applied to data from 26,645 esas questionnaires completed at the Juravinski Cancer Centre. The fit of the esas to the polytomous Rasch model was investigated, including evaluations of differential item functioning for sex, age, and disease group. The research implication was investigated by comparing the results of an observational research study previously analysed using a traditional approach with the results obtained by Rasch-proposed interval-level esas scoring. The Rasch reliability index was 0.73, falling short of the desired 0.80-0.90 level. However, the esas was found to fit the Rasch model, including the criteria for uni-dimensional data. The analysis suggests that the current esas scoring system of 0-10 could be collapsed to a 6-point scale. Use of the Rasch-proposed interval-level scoring yielded results that were different from those calculated using summarized ordinal-level esas scores. Differential item functioning was not found for sex, age, or diagnosis groups. The esas is a moderately reliable uni-dimensional measure of cancer disease burden and can provide interval-level scaling with Rasch-based scoring. Further, our study indicates that, compared with the traditional scoring metric, Rasch-based scoring could result in substantive changes to conclusions.
Yoon, Jong H.; Tamir, Diana; Minzenberg, Michael J.; Ragland, J. Daniel; Ursu, Stefan; Carter, Cameron S.
2009-01-01
Background Multivariate pattern analysis is an alternative method of analyzing fMRI data, which is capable of decoding distributed neural representations. We applied this method to test the hypothesis of the impairment in distributed representations in schizophrenia. We also compared the results of this method with traditional GLM-based univariate analysis. Methods 19 schizophrenia and 15 control subjects viewed two runs of stimuli--exemplars of faces, scenes, objects, and scrambled images. To verify engagement with stimuli, subjects completed a 1-back matching task. A multi-voxel pattern classifier was trained to identify category-specific activity patterns on one run of fMRI data. Classification testing was conducted on the remaining run. Correlation of voxel-wise activity across runs evaluated variance over time in activity patterns. Results Patients performed the task less accurately. This group difference was reflected in the pattern analysis results with diminished classification accuracy in patients compared to controls, 59% and 72% respectively. In contrast, there was no group difference in GLM-based univariate measures. In both groups, classification accuracy was significantly correlated with behavioral measures. Both groups showed highly significant correlation between inter-run correlations and classification accuracy. Conclusions Distributed representations of visual objects are impaired in schizophrenia. This impairment is correlated with diminished task performance, suggesting that decreased integrity of cortical activity patterns is reflected in impaired behavior. Comparisons with univariate results suggest greater sensitivity of pattern analysis in detecting group differences in neural activity and reduced likelihood of non-specific factors driving these results. PMID:18822407
Reliability Assessment of Graphite Specimens under Multiaxial Stresses
NASA Technical Reports Server (NTRS)
Sookdeo, Steven; Nemeth, Noel N.; Bratton, Robert L.
2008-01-01
An investigation was conducted to predict the failure strength response of IG-100 nuclear grade graphite exposed to multiaxial stresses. As part of this effort, a review of failure criteria accounting for the stochastic strength response is provided. The experimental work was performed in the early 1990s at the Oak Ridge National Laboratory (ORNL) on hollow graphite tubes under the action of axial tensile loading and internal pressurization. As part of the investigation, finite-element analysis (FEA) was performed and compared with results of FEA from the original ORNL report. The new analysis generally compared well with the original analysis, although some discrepancies in the location of peak stresses was noted. The Ceramics Analysis and Reliability Evaluation of Structures Life prediction code (CARES/Life) was used with the FEA results to predict the quadrants I (tensile-tensile) and quadrant IV (compression-tension) strength response of the graphite tubes for the principle of independent action (PIA), the Weibull normal stress averaging (NSA), and the Batdorf multiaxial failure theories. The CARES/Life reliability analysis showed that all three failure theories gave similar results in quadrant I but that in quadrant IV, the PIA and Weibull normal stress-averaging theories were not conservative, whereas the Batdorf theory was able to correlate well with experimental results. The conclusion of the study was that the Batdorf theory should generally be used to predict the reliability response of graphite and brittle materials in multiaxial loading situations.
Nikniaz, Zeinab; Somi, Mohammad Hossein; Nagashi, Shahnaz; Nikniaz, Leila
2017-07-01
The present systematic review and meta-analysis study evaluated the impact of early enteral nutrition (EN) on postoperative nutritional and immunological outcomes of gastric cancer (GC) patients. The databases of PubMed, Embase, Springer, and Cochrane library were searched till September 2016 to identify studies which evaluated the effects of EN compared with parenteral nutrition (PN) on postoperative immunological and nutritional status and hospitalization time in GC patients. Mean difference (MD) or standard mean difference (SMD) was calculated and I-square statistic test was used for heterogeneity analysis. The present systematic review and meta-analysis have consisted of seven trials, containing 835 GC patients. According to the result of meta-analysis, compared with PN, EN significantly resulted in more increase in the level of albumin [MD = 2.07 (0.49, 3.64)], prealbumin [MD = 9.41 (049, 33.55)], weight [MD = 1.52 (0.32, 2.72)], CD3+ [SMD = 1.96 (1.50, 2.43)], CD4+ [SMD = 2.45 (1.97, 2.93)], natural killers [MD = 5.80 (3.75, 7.85)], and also a decrease in the hospitalization time [MD=-2.39 (-2.74, -2.03)]. The results demonstrated that early administration of EN is more effective in improving postsurgical nutrition status and immune index in GC patients. So, based on these results, postoperative early administration of EN is recommended for GC patients where possible.
Interleukin-10-1082G/A polymorphism and acute liver graft rejection: A meta-analysis
Liu, Fei; Li, Bo; Wang, Wen-Tao; Wei, Yong-Gang; Yan, Lv-Nan; Wen, Tian-Fu; Xu, Ming-Qing; Yang, Jia-Yin
2012-01-01
AIM: To investigate the association between interleukin (IL)-10-1082 (G/A) promoter polymorphism and acute rejection (AR) in liver transplant (LT) recipients. METHODS: Two investigators independently searched the Medline, Embase, China National Knowledge Infrastructure, and Chinese Biomedicine Databases. Summary odds ratios (ORs) and 95% CIs for IL-10-1082 G/A polymorphism and AR were calculated in a fixed- and a random-effects model as appropriate. RESULTS: This meta-analysis included seven case-control studies, which comprised 652 cases of LT recipients in which 241 cases developed AR and 411 cases did not develop AR. Overall, the variant A allele was not associated with AR risk when compared with the wild-type G allele (OR = 0.94, 95% CI: 0.64-1.39). Moreover, similar results were observed when the AA genotype was compared with the AG/GG genotype (OR = 1.05, 95% CI: 0.55-2.02). When stratifying for ethnicity, no significant association was observed among either Caucasians or Asians. Because only one study was performed in Asian patients, the result of subgroup analysis by ethnicity would not be reliable for Asians. Limiting the analysis to the studies with controls in the Hardy-Weinberg equilibrium, the results were persistent and robust. No publication bias was found in the present study. CONCLUSION: This meta-analysis suggests that IL-10-1082 G/A polymorphism may be not associated with AR risk in LT recipients among Caucasians. PMID:22371646
Grati, Francesca R; Malvestiti, Francesca; Grimi, Beatrice; Gaetani, Elisa; Di Meco, Anna Maria; Trotta, Anna; Liuti, Rosaria; Chinetti, Sara; Dulcetti, Francesca; Ruggeri, Anna Maria; Agrati, Cristina; Frascoli, Giuditta; Milani, Silvia; De Toffol, Simona; Martinoni, Lorenza; Paganini, Silvia; Marcato, Livia; Maggi, Federico; Simoni, Giuseppe
2013-05-01
Karyotyping on chorionic villous samples (CVS) includes the analysis of both cytotrophoblast (STC) and mesenchyme (LTC). This approach requires complex laboratory organization and trained technicians. The introduction of quantitative fluorescent polymerase chain reaction (QF-PCR) instead of conventional karyotyping in low-risk pregnancies opened its application in CVS analysis. Discordant QF-PCR and CVS cytogenetic results were reported, and strategies for CVS analysis were introduced to minimize this risk. The possibility to substitute the STC with QF-PCR was reported. The aim of this study is to evaluate benefits and limitations of the approach QF-PCR + LTC compared with the traditional method STC + LTC and to quantify the associated risks of false results. This study is based on a retrospective cytogenetic audit of CVS results (n = 44 727) generated by the STC + LTC analytic approach. False-negative risks related to true fetal mosaicism type IV, imprinting syndromes and maternal contamination in LTC were calculated. Compared with STC + LTC, QF-PCR + LTC approach is associated with a cumulative false-negative risk of ~1/3100-1/4400. Costs and reporting time of STC in a high-throughput cytogenetic lab are similar to a CE-IVD marked QF-PCR analysis. These results should be clearly highlighted in the pre-test counseling and extensively discussed with the couple prior to testing for informed consent. © 2013 John Wiley & Sons, Ltd.
15 years of comet photometry: A comparative analysis of 80 comets
NASA Technical Reports Server (NTRS)
Osip, David J.; Schleicher, David G.; Millis, Robert L.; Hearn, M. F. A.; Birch, P. V.
1992-01-01
In 1976 we began a program of narrowband photometry of comets that has encompassed well over 400 nights of observations. To date, the program has provided detailed information on 80 comets, 11 of which have been observed on multiple apparitions. In this paper we present the observed range of compositions (molecular production rate ratios) and dustiness (gas production compared with AF-rho) for a well sampled group of comets. Based on these results we present preliminary analysis of taxonomic groupings as well as the abundance ratios we associate with a 'typical' comet.
Nichitayio, M Yu; Bazyak, A M; Klochan, V V; Grusha, P K; Goman, A V
2015-02-01
Comparative analysis of results of the laser diode (the wave length 940 nm) and elec- trocoagulation application while performing laparoscopic cholecystectomy was con- ducted. For an acute calculous cholecystitis 52 patients were operated, in whom instead of electrocoagulation the laser was applied, provide for reduction of thermal impact on tissues, the complications absence, reduction of the patients stationary treatment duration postoperatively from (5.2 ± 1.2) to (4.9 ± 0.6) days.
Power flow analysis of two coupled plates with arbitrary characteristics
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1990-01-01
In the last progress report (Feb. 1988) some results were presented for a parametric analysis on the vibrational power flow between two coupled plate structures using the mobility power flow approach. The results reported then were for changes in the structural parameters of the two plates, but with the two plates identical in their structural characteristics. Herein, limitation is removed. The vibrational power input and output are evaluated for different values of the structural damping loss factor for the source and receiver plates. In performing this parametric analysis, the source plate characteristics are kept constant. The purpose of this parametric analysis is to determine the most critical parameters that influence the flow of vibrational power from the source plate to the receiver plate. In the case of the structural damping parametric analysis, the influence of changes in the source plate damping is also investigated. The results obtained from the mobility power flow approach are compared to results obtained using a statistical energy analysis (SEA) approach. The significance of the power flow results are discussed together with a discussion and a comparison between the SEA results and the mobility power flow results. Furthermore, the benefits derived from using the mobility power flow approach are examined.