Test 6, Test 7, and Gas Standard Analysis Results
NASA Technical Reports Server (NTRS)
Perez, Horacio, III
2007-01-01
This viewgraph presentation shows results of analyses on odor, toxic off gassing and gas standards. The topics include: 1) Statistical Analysis Definitions; 2) Odor Analysis Results NASA Standard 6001 Test 6; 3) Toxic Off gassing Analysis Results NASA Standard 6001 Test 7; and 4) Gas Standard Results NASA Standard 6001 Test 7;
Dynamic test/analysis correlation using reduced analytical models
NASA Technical Reports Server (NTRS)
Mcgowan, Paul E.; Angelucci, A. Filippo; Javeed, Mehzad
1992-01-01
Test/analysis correlation is an important aspect of the verification of analysis models which are used to predict on-orbit response characteristics of large space structures. This paper presents results of a study using reduced analysis models for performing dynamic test/analysis correlation. The reduced test-analysis model (TAM) has the same number and orientation of DOF as the test measurements. Two reduction methods, static (Guyan) reduction and the Improved Reduced System (IRS) reduction, are applied to the test/analysis correlation of a laboratory truss structure. Simulated test results and modal test data are used to examine the performance of each method. It is shown that selection of DOF to be retained in the TAM is critical when large structural masses are involved. In addition, the use of modal test results may provide difficulties in TAM accuracy even if a large number of DOF are retained in the TAM.
Results and analysis of the switchyard impact tests
DOT National Transportation Integrated Search
1980-01-01
This report presents the results and analysis of series 3 through 7 and series 10 of the FRA/RPI/AAR Switchyard Impact Tests. The test results and analysis are used to evaluate the head shield and the shelf-E coupler as protective devices for hazardo...
NASA Technical Reports Server (NTRS)
Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.
2016-01-01
This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.
Composite Failures: A Comparison of Experimental Test Results and Computational Analysis Using XFEM
2016-09-30
NUWC-NPT Technical Report 12,218 30 September 2016 Composite Failures: A Comparison of Experimental Test Results and Computational Analysis...A Comparison of Experimental Test Results and Computational Analysis Using XFEM 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...availability of measurement techniques, experimental testing of composite materials has largely outpaced the computational modeling ability, forcing
Analysis of Phenix end-of-life natural convection test with the MARS-LMR code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeong, H. Y.; Ha, K. S.; Lee, K. L.
The end-of-life test of Phenix reactor performed by the CEA provided an opportunity to have reliable and valuable test data for the validation and verification of a SFR system analysis code. KAERI joined this international program for the analysis of Phenix end-of-life natural circulation test coordinated by the IAEA from 2008. The main objectives of this study were to evaluate the capability of existing SFR system analysis code MARS-LMR and to identify any limitation of the code. The analysis was performed in three stages: pre-test analysis, blind posttest analysis, and final post-test analysis. In the pre-test analysis, the design conditionsmore » provided by the CEA were used to obtain a prediction of the test. The blind post-test analysis was based on the test conditions measured during the tests but the test results were not provided from the CEA. The final post-test analysis was performed to predict the test results as accurate as possible by improving the previous modeling of the test. Based on the pre-test analysis and blind test analysis, the modeling for heat structures in the hot pool and cold pool, steel structures in the core, heat loss from roof and vessel, and the flow path at core outlet were reinforced in the final analysis. The results of the final post-test analysis could be characterized into three different phases. In the early phase, the MARS-LMR simulated the heat-up process correctly due to the enhanced heat structure modeling. In the mid phase before the opening of SG casing, the code reproduced the decrease of core outlet temperature successfully. Finally, in the later phase the increase of heat removal by the opening of the SG opening was well predicted with the MARS-LMR code. (authors)« less
CPAS Preflight Drop Test Analysis Process
NASA Technical Reports Server (NTRS)
Englert, Megan E.; Bledsoe, Kristin J.; Romero, Leah M.
2015-01-01
Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.
TSP Symposium 2013 Proceedings
2014-01-01
test and Post - test Results of the Experimental Group Our results show that the experimental group improved on the post - test compared...4.3.4 Design of the Learning Strategy 27 4.4 Results 28 4.4.1 Post - test 28 4.4.2 Analysis of the Results 28 4.4.3 Analysis of the Results from the...Estimation Accuracy) 17 Figure 5: Methodology for the Research 24 Figure 6: Question 1, Time Control for Post - test 28 Figure 7:
ERIC Educational Resources Information Center
Lonchamp, F.
This is a presentation of the results of a factor analysis of a battery of tests intended to measure listening and reading comprehension in English as a second language. The analysis sought to answer the following questions: (1) whether the factor analysis method yields results when applied to tests which are not specifically designed for this…
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 6 2013-10-01 2013-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 6 2012-10-01 2012-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
46 CFR 164.007-7 - Analysis of results.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 6 2014-10-01 2014-10-01 false Analysis of results. 164.007-7 Section 164.007-7...: SPECIFICATIONS AND APPROVAL MATERIALS Structural Insulations § 164.007-7 Analysis of results. (a) When only one sample is tested, the results of the test shall be binding and no analysis by the Coast Guard will be...
Standardized Test Results: An Opportunity for English Program Improvement
ERIC Educational Resources Information Center
Jiménez, Maureyra; Rodríguez, Caroll; Rey Paba, Lourdes
2017-01-01
This case study explores the relationship between the results obtained by a group of Industrial Engineering students on a national standardized English test and the impact these results had on language program improvement. The instruments used were interviews, document analysis, observations, surveys, and test results analysis. Findings indicate…
NASA Astrophysics Data System (ADS)
Nepomuceno, Miguel C. S.; Lopes, Sérgio M. R.
2017-10-01
Non-destructive tests (NDT) have been used in the last decades for the assessment of in-situ quality and integrity of concrete elements. An important step in the application of NDT methods concerns to the interpretation and validation of the test results. In general, interpretation of NDT results should involve three distinct phases leading to the development of conclusions: processing of collected data, analysis of within-test variability and quantitative evaluation of property under investigation. The analysis of within-test variability can provide valuable information, since this can be compared with that of within-test variability associated with the NDT method in use, either to provide a measure of the quality control or to detect the presence of abnormal circumstances during the in-situ application. This paper reports the analysis of the experimental results of within-test variability of NDT obtained for normal vibrated concrete and self-compacting concrete. The NDT reported includes the surface hardness test, ultrasonic pulse velocity test, penetration resistance test, pull-off test, pull-out test and maturity test. The obtained results are discussed and conclusions are presented.
TRAC-PD2 posttest analysis of the CCTF Evaluation-Model Test C1-19 (Run 38). [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Motley, F.
The results of a Transient Reactor Analysis Code posttest analysis of the Cylindral Core Test Facility Evaluation-Model Test agree very well with the results of the experiment. The good agreement obtained verifies the multidimensional analysis capability of the TRAC code. Because of the steep radial power profile, the importance of using fine noding in the core region was demonstrated (as compared with poorer results obtained from an earlier pretest prediction that used a coarsely noded model).
NASA Technical Reports Server (NTRS)
Howland, G. R.; Durno, J. A.; Twomey, W. J.
1990-01-01
Sikorsky Aircraft, together with the other major helicopter airframe manufacturers, is engaged in a study to improve the use of finite element analysis to predict the dynamic behavior of helicopter airframes, under a rotorcraft structural dynamics program called DAMVIBS (Design Analysis Methods for VIBrationS), sponsored by the NASA-Langley. The test plan and test results are presented for a shake test of the UH-60A BLACK HAWK helicopter. A comparison is also presented of test results with results obtained from analysis using a NASTRAN finite element model.
Buckling Testing and Analysis of Space Shuttle Solid Rocket Motor Cylinders
NASA Technical Reports Server (NTRS)
Weidner, Thomas J.; Larsen, David V.; McCool, Alex (Technical Monitor)
2002-01-01
A series of full-scale buckling tests were performed on the space shuttle Reusable Solid Rocket Motor (RSRM) cylinders. The tests were performed to determine the buckling capability of the cylinders and to provide data for analytical comparison. A nonlinear ANSYS Finite Element Analysis (FEA) model was used to represent and evaluate the testing. Analytical results demonstrated excellent correlation to test results, predicting the failure load within 5%. The analytical value was on the conservative side, predicting a lower failure load than was applied to the test. The resulting study and analysis indicated the important parameters for FEA to accurately predict buckling failure. The resulting method was subsequently used to establish the pre-launch buckling capability of the space shuttle system.
Statistical analysis of Skylab 3. [endocrine/metabolic studies of astronauts
NASA Technical Reports Server (NTRS)
Johnston, D. A.
1974-01-01
The results of endocrine/metabolic studies of astronauts on Skylab 3 are reported. One-way analysis of variance, contrasts, two-way unbalanced analysis of variance, and analysis of periodic changes in flight are included. Results for blood tests, and urine tests are presented.
Impact of uncertainty on modeling and testing
NASA Technical Reports Server (NTRS)
Coleman, Hugh W.; Brown, Kendall K.
1995-01-01
A thorough understanding of the uncertainties associated with the modeling and testing of the Space Shuttle Main Engine (SSME) Engine will greatly aid decisions concerning hardware performance and future development efforts. This report will describe the determination of the uncertainties in the modeling and testing of the Space Shuttle Main Engine test program at the Technology Test Bed facility at Marshall Space Flight Center. Section 2 will present a summary of the uncertainty analysis methodology used and discuss the specific applications to the TTB SSME test program. Section 3 will discuss the application of the uncertainty analysis to the test program and the results obtained. Section 4 presents the results of the analysis of the SSME modeling effort from an uncertainty analysis point of view. The appendices at the end of the report contain a significant amount of information relative to the analysis, including discussions of venturi flowmeter data reduction and uncertainty propagation, bias uncertainty documentations, technical papers published, the computer code generated to determine the venturi uncertainties, and the venturi data and results used in the analysis.
Development of Test-Analysis Models (TAM) for correlation of dynamic test and analysis results
NASA Technical Reports Server (NTRS)
Angelucci, Filippo; Javeed, Mehzad; Mcgowan, Paul
1992-01-01
The primary objective of structural analysis of aerospace applications is to obtain a verified finite element model (FEM). The verified FEM can be used for loads analysis, evaluate structural modifications, or design control systems. Verification of the FEM is generally obtained as the result of correlating test and FEM models. A test analysis model (TAM) is very useful in the correlation process. A TAM is essentially a FEM reduced to the size of the test model, which attempts to preserve the dynamic characteristics of the original FEM in the analysis range of interest. Numerous methods for generating TAMs have been developed in the literature. The major emphasis of this paper is a description of the procedures necessary for creation of the TAM and the correlation of the reduced models with the FEM or the test results. Herein, three methods are discussed, namely Guyan, Improved Reduced System (IRS), and Hybrid. Also included are the procedures for performing these analyses using MSC/NASTRAN. Finally, application of the TAM process is demonstrated with an experimental test configuration of a ten bay cantilevered truss structure.
SRG110 Stirling Generator Dynamic Simulator Vibration Test Results and Analysis Correlation
NASA Technical Reports Server (NTRS)
Suarez, Vicente J.; Lewandowski, Edward J.; Callahan, John
2006-01-01
The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Stirling Radioisotope Generator (SRG110) for use as a power system for space science missions. The launch environment enveloping potential missions results in a random input spectrum that is significantly higher than historical RPS launch levels and is a challenge for designers. Analysis presented in prior work predicted that tailoring the compliance at the generator-spacecraft interface reduced the dynamic response of the system thereby allowing higher launch load input levels and expanding the range of potential generator missions. To confirm analytical predictions, a dynamic simulator representing the generator structure, Stirling convertors and heat sources was designed and built for testing with and without a compliant interface. Finite element analysis was performed to guide the generator simulator and compliant interface design so that test modes and frequencies were representative of the SRG110 generator. This paper presents the dynamic simulator design, the test setup and methodology, test article modes and frequencies and dynamic responses, and post-test analysis results. With the compliant interface, component responses to an input environment exceeding the SRG110 qualification level spectrum were all within design allowables. Post-test analysis included finite element model tuning to match test frequencies and random response analysis using the test input spectrum. Analytical results were in good overall agreement with the test results and confirmed previous predictions that the SRG110 power system may be considered for a broad range of potential missions, including those with demanding launch environments.
SRG110 Stirling Generator Dynamic Simulator Vibration Test Results and Analysis Correlation
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Suarez, Vicente J.; Goodnight, Thomas W.; Callahan, John
2007-01-01
The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Stirling Radioisotope Generator (SRG110) for use as a power system for space science missions. The launch environment enveloping potential missions results in a random input spectrum that is significantly higher than historical radioisotope power system (RPS) launch levels and is a challenge for designers. Analysis presented in prior work predicted that tailoring the compliance at the generator-spacecraft interface reduced the dynamic response of the system thereby allowing higher launch load input levels and expanding the range of potential generator missions. To confirm analytical predictions, a dynamic simulator representing the generator structure, Stirling convertors and heat sources were designed and built for testing with and without a compliant interface. Finite element analysis was performed to guide the generator simulator and compliant interface design so that test modes and frequencies were representative of the SRG110 generator. This paper presents the dynamic simulator design, the test setup and methodology, test article modes and frequencies and dynamic responses, and post-test analysis results. With the compliant interface, component responses to an input environment exceeding the SRG110 qualification level spectrum were all within design allowables. Post-test analysis included finite element model tuning to match test frequencies and random response analysis using the test input spectrum. Analytical results were in good overall agreement with the test results and confirmed previous predictions that the SRG110 power system may be considered for a broad range of potential missions, including those with demanding launch environments.
Measurement uncertainty analysis techniques applied to PV performance measurements
NASA Astrophysics Data System (ADS)
Wells, C.
1992-10-01
The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.
Substantiation Data for Advanced Beaded and Tubular Structural Panels. Volume 3: Testing
NASA Technical Reports Server (NTRS)
Hedges, P. C.; Greene, B. E.
1974-01-01
The test program is described, which was conducted to provide the necessary experimental data to verify the design and analysis methods developed for beaded and tubular panels. Test results are summarized and presented for all local buckling and full size panel tests. Selected representative test data from each of these tests is presented in detail. The results of this program established a valid analysis and design procedure for circular tube panels. Test results from three other configurations show deformational modes which are not adequately accounted for in the present analyses.
40 CFR 265.200 - Waste analysis and trial tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operator to place the results from each waste analysis and trial test, or the documented information, in... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Waste analysis and trial tests. 265... DISPOSAL FACILITIES Tank Systems § 265.200 Waste analysis and trial tests. In addition to performing the...
40 CFR 265.200 - Waste analysis and trial tests.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operator to place the results from each waste analysis and trial test, or the documented information, in... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Waste analysis and trial tests. 265... DISPOSAL FACILITIES Tank Systems § 265.200 Waste analysis and trial tests. In addition to performing the...
40 CFR 265.200 - Waste analysis and trial tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operator to place the results from each waste analysis and trial test, or the documented information, in... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Waste analysis and trial tests. 265... DISPOSAL FACILITIES Tank Systems § 265.200 Waste analysis and trial tests. In addition to performing the...
40 CFR 265.200 - Waste analysis and trial tests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator to place the results from each waste analysis and trial test, or the documented information, in... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Waste analysis and trial tests. 265... DISPOSAL FACILITIES Tank Systems § 265.200 Waste analysis and trial tests. In addition to performing the...
40 CFR 265.200 - Waste analysis and trial tests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operator to place the results from each waste analysis and trial test, or the documented information, in... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Waste analysis and trial tests. 265... DISPOSAL FACILITIES Tank Systems § 265.200 Waste analysis and trial tests. In addition to performing the...
A shift from significance test to hypothesis test through power analysis in medical research.
Singh, G
2006-01-01
Medical research literature until recently, exhibited substantial dominance of the Fisher's significance test approach of statistical inference concentrating more on probability of type I error over Neyman-Pearson's hypothesis test considering both probability of type I and II error. Fisher's approach dichotomises results into significant or not significant results with a P value. The Neyman-Pearson's approach talks of acceptance or rejection of null hypothesis. Based on the same theory these two approaches deal with same objective and conclude in their own way. The advancement in computing techniques and availability of statistical software have resulted in increasing application of power calculations in medical research and thereby reporting the result of significance tests in the light of power of the test also. Significance test approach, when it incorporates power analysis contains the essence of hypothesis test approach. It may be safely argued that rising application of power analysis in medical research may have initiated a shift from Fisher's significance test to Neyman-Pearson's hypothesis test procedure.
Brown, Geoffrey W.; Sandstrom, Mary M.; Preston, Daniel N.; ...
2014-11-17
In this study, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency test for small-scale safety and thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results from this test for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Class 5 Type II standard. The material was tested as a well-characterized standard several times during the proficiency test to assess differences among participants and the range of results that may arise for well-behaved explosive materials.
NASA Technical Reports Server (NTRS)
Sander, Erik J.; Gosdin, Dennis R.
1992-01-01
Engineers regularly analyze SSME ground test and flight data with respect to engine systems performance. Recently, a redesigned SSME powerhead was introduced to engine-level testing in part to increase engine operational margins through optimization of the engine internal environment. This paper presents an overview of the MSFC personnel engine systems analysis results and conclusions reached from initial engine level testing of the redesigned powerhead, and further redesigns incorporated to eliminate accelerated main injector baffle and main combustion chamber hot gas wall degradation. The conclusions are drawn from instrumented engine ground test data and hardware integrity analysis reports and address initial engine test results with respect to the apparent design change effects on engine system and component operation.
Structural Analysis and Testing of an Erectable Truss for Precision Segmented Reflector Application
NASA Technical Reports Server (NTRS)
Collins, Timothy J.; Fichter, W. B.; Adams, Richard R.; Javeed, Mehzad
1995-01-01
This paper describes analysis and test results obtained at Langley Research Center (LaRC) on a doubly curved testbed support truss for precision reflector applications. Descriptions of test procedures and experimental results that expand upon previous investigations are presented. A brief description of the truss is given, and finite-element-analysis models are described. Static-load and vibration test procedures are discussed, and experimental results are shown to be repeatable and in generally good agreement with linear finite-element predictions. Truss structural performance (as determined by static deflection and vibration testing) is shown to be predictable and very close to linear. Vibration test results presented herein confirm that an anomalous mode observed during initial testing was due to the flexibility of the truss support system. Photogrammetric surveys with two 131-in. reference scales show that the root-mean-square (rms) truss-surface accuracy is about 0.0025 in. Photogrammetric measurements also indicate that the truss coefficient of thermal expansion (CTE) is in good agreement with that predicted by analysis. A detailed description of the photogrammetric procedures is included as an appendix.
Nonlinear Analysis and Preliminary Testing Results of a Hybrid Wing Body Center Section Test Article
NASA Technical Reports Server (NTRS)
Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.; Wu, Hsi-Yung T.
2015-01-01
A large test article was recently designed, analyzed, fabricated, and successfully tested up to the representative design ultimate loads to demonstrate that stiffened composite panels with through-the-thickness reinforcement are a viable option for the next generation large transport category aircraft, including non-conventional configurations such as the hybrid wing body. This paper focuses on finite element analysis and test data correlation of the hybrid wing body center section test article under mechanical, pressure and combined load conditions. Good agreement between predictive nonlinear finite element analysis and test data is found. Results indicate that a geometrically nonlinear analysis is needed to accurately capture the behavior of the non-circular pressurized and highly-stressed structure when the design approach permits local buckling.
Rossano, Mary G; Murphy, Alice J; Vrable, Ruth A; Vanzo, Nicole E; Lewis, Stacy K; Sheline, Katherine D; Kaneene, John B; Mansfield, Linda S
2002-08-15
To determine apparent seroprevalence of antibodies against Sarcocystis neurona in a population of domestic cats previously tested for antibodies against Toxoplasma gondii. Cross-sectional study. Serum from 196 domestic cats. Banked serum samples submitted to the Michigan State University Animal Health Diagnostic Laboratory for T. gondii diagnostic testing were tested for antibodies against S. neurona by use of an indirect fluorescent antibody (IFA) test and a western blot test. Submission records were analyzed to determine descriptive statistics and test for associations between positive results of a test for S. neurona and other variables in the data set. 10 of 196 (5%) samples yielded positive results for antibodies against S. neurona by use of western blot analysis, whereas 27 samples yielded positive results by use of the IFA. No association was found between S. neurona western blot test results and T. gondii test results, age, sex, or the reason for T. gondii testing. The S. neurona IFA titer was positively and significantly associated with positive results of western blot analysis. Domestic cats are not likely to play a substantial role as intermediate hosts in the natural life cycle of S. neurona. Results indicate that natural infection of domestic cats may occur, and small animal practitioners should be aware of this fact when evaluating cats with neurologic disease. The S. neurona IFA test had lower specificity than western blot analysis.
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.; Dieck, Ronald H.; Chuang, Isaac
1987-01-01
A preliminary uncertainty analysis was performed for the High Area Ratio Rocket Nozzle test program which took place at the altitude test capsule of the Rocket Engine Test Facility at the NASA Lewis Research Center. Results from the study establish the uncertainty of measured and calculated parameters required for the calculation of rocket engine specific impulse. A generalized description of the uncertainty methodology used is provided. Specific equations and a detailed description of the analysis is presented. Verification of the uncertainty analysis model was performed by comparison with results from the experimental program's data reduction code. Final results include an uncertainty for specific impulse of 1.30 percent. The largest contributors to this uncertainty were calibration errors from the test capsule pressure and thrust measurement devices.
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.; Dieck, Ronald H.; Chuang, Isaac
1987-01-01
A preliminary uncertainty analysis has been performed for the High Area Ratio Rocket Nozzle test program which took place at the altitude test capsule of the Rocket Engine Test Facility at the NASA Lewis Research Center. Results from the study establish the uncertainty of measured and calculated parameters required for the calculation of rocket engine specific impulse. A generalized description of the uncertainty methodology used is provided. Specific equations and a detailed description of the analysis are presented. Verification of the uncertainty analysis model was performed by comparison with results from the experimental program's data reduction code. Final results include an uncertainty for specific impulse of 1.30 percent. The largest contributors to this uncertainty were calibration errors from the test capsule pressure and thrust measurement devices.
Wang, D Z; Wang, C; Shen, C F; Zhang, Y; Zhang, H; Song, G D; Xue, X D; Xu, Z L; Zhang, S; Jiang, G H
2017-05-10
We described the time trend of acute myocardial infarction (AMI) from 1999 to 2013 in Tianjin incidence rate with Cochran-Armitage trend (CAT) test and linear regression analysis, and the results were compared. Based on actual population, CAT test had much stronger statistical power than linear regression analysis for both overall incidence trend and age specific incidence trend (Cochran-Armitage trend P value
NASA Technical Reports Server (NTRS)
1978-01-01
A three-dimensional finite elements analysis is reported of the nonlinear behavior of PCRV subjected to internal pressure by comparing calculated results with test results. As the first stage, an analysis considering the nonlinearity of cracking in concrete was attempted. As a result, it is found possible to make an analysis up to three times the design pressure (50 kg/sqcm), and calculated results agree well with test results.
Medical University admission test: a confirmatory factor analysis of the results.
Luschin-Ebengreuth, Marion; Dimai, Hans P; Ithaler, Daniel; Neges, Heide M; Reibnegger, Gilbert
2016-05-01
The Graz Admission Test has been applied since the academic year 2006/2007. The validity of the Test was demonstrated by a significant improvement of study success and a significant reduction of dropout rate. The purpose of this study was a detailed analysis of the internal correlation structure of the various components of the Graz Admission Test. In particular, the question investigated was whether or not the various test parts constitute a suitable construct which might be designated as "Basic Knowledge in Natural Science." This study is an observational investigation, analyzing the results of the Graz Admission Test for the study of human medicine and dentistry. A total of 4741 applicants were included in the analysis. Principal component factor analysis (PCFA) as well as techniques from structural equation modeling, specifically confirmatory factor analysis (CFA), were employed to detect potential underlying latent variables governing the behavior of the measured variables. PCFA showed good clustering of the science test parts, including also text comprehension. A putative latent variable "Basic Knowledge in Natural Science," investigated by CFA, was indeed shown to govern the response behavior of the applicants in biology, chemistry, physics, and mathematics as well as text comprehension. The analysis of the correlation structure of the various test parts confirmed that the science test parts together with text comprehension constitute a satisfactory instrument for measuring a latent construct variable "Basic Knowledge in Natural Science." The present results suggest the fundamental importance of basic science knowledge for results obtained in the framework of the admission process for medical universities.
[Phoneme analysis and phoneme discrimination of juvenile speech therapy school students].
Franz, S; Rosanowski, F; Eysholdt, U; Hoppe, U
2011-05-01
Phoneme analysis and phoneme discrimination, important factors in acquiring spoken and written language, have been evaluated in juvenile speech therapy school students. The results have been correlated with the results of a school achievement test. The following questions were of interest: Do students in the lower verbal skill segment show pathological phoneme analysis and phoneme discrimination skills? Do the results of the school achievement test differ from the results by students visiting German "Hauptschule"? How does phoneme analysis and phoneme discrimination performance correlate to other tested parameters? 74 students of a speech therapy school ranging from 7 (th) to 9 (th) grade were examined (ages 12;10-17;04) with the Heidelberg Phoneme Discrimination Test H-LAD and the school achievement test "Prüfsystem für Schul- und Bildungsberatung PSB-R 6-13". Compared to 4 (th) graders the juvenile speech therapy school students showed worse results in the H-LAD test with good differentiation in the lower measuring range. In the PSB-R 6-13 test the examined students did worse compared to students visiting German "Hauptschule" for all grades except 9 (th) grade. Comparing H-LAD and PSB-R 6-13 shows a significant correlation for the sub-tests covering language competence and intelligence but not for the concentration tests. Pathological phoneme analysis and phoneme discrimination skills suggest elevated need for counseling, but this needs to corroborated through additional linguistic parameters and measuring non-verbal intelligence. Further trails are needed in order to clarify whether the results can lead to sophisticated therapy algorithms for educational purposes. © Georg Thieme Verlag KG Stuttgart · New York.
Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates, Phase II Results
NASA Technical Reports Server (NTRS)
Allen, P. A.; Wells, D. N.
2017-01-01
The second phase of an analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted under the auspices of ASTM Interlaboratory Study 732. The interlaboratory study (ILS) had 10 participants with a broad range of expertise and experience, and experimental results from a surface crack tension test in 4142 steel plate loaded well into the elastic-plastic regime provided the basis for the study. The participants were asked to evaluate a surface crack tension test according to the version of the surface crack initiation toughness testing standard published at the time of the ILS, E2899-13. Data were provided to each participant that represent the fundamental information that would be provided by a mechanical test laboratory prior to evaluating the test result. Overall, the participant’s test analysis results were in good agreement and constructive feedback was received that has resulted in an improved published version of the standard E2899-15.
Computational Fluid Dynamics Analysis Success Stories of X-Plane Design to Flight Test
NASA Technical Reports Server (NTRS)
Cosentino, Gary B.
2008-01-01
Examples of the design and flight test of three true X-planes are described, particularly X-plane design techniques that relied heavily on computational fluid dynamics(CFD) analysis. Three examples are presented: the X-36 Tailless Fighter Agility Research Aircraft, the X-45A Unmanned Combat Air Vehicle, and the X-48B Blended Wing Body Demonstrator Aircraft. An overview is presented of the uses of CFD analysis, comparison and contrast with wind tunnel testing, and information derived from CFD analysis that directly related to successful flight test. Lessons learned on the proper and improper application of CFD analysis are presented. Highlights of the flight-test results of the three example X-planes are presented. This report discusses developing an aircraft shape from early concept and three-dimensional modeling through CFD analysis, wind tunnel testing, further refined CFD analysis, and, finally, flight. An overview of the areas in which CFD analysis does and does not perform well during this process is presented. How wind tunnel testing complements, calibrates, and verifies CFD analysis is discussed. Lessons learned revealing circumstances under which CFD analysis results can be misleading are given. Strengths and weaknesses of the various flow solvers, including panel methods, Euler, and Navier-Stokes techniques, are discussed.
Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care.
Menon, Shailaja; Murphy, Daniel R; Singh, Hardeep; Meyer, Ashley N D; Sittig, Dean F
2016-01-01
Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Workarounds to manage EHR-based test results are common, and their use results from unmet provider information management needs. Future EHRs and the respective work systems around them need to evolve to meet these needs.
Analysis and Design of a Double-Divert Spiral Groove Seal
NASA Technical Reports Server (NTRS)
Zheng, Xiaoqing; Berard, Gerald
2007-01-01
This viewgraph presentation describes the design and analysis of a double spiral groove seal. The contents include: 1) Double Spiral Design Features; 2) Double Spiral Operational Features; 3) Mating Ring/Rotor Assembly; 4) Seal Ring Assembly; 5) Insert Segment Joints; 6) Rotor Assembly Completed Prototype Parts; 7) Seal Assembly Completed Prototype Parts; 8) Finite Element Analysis; 9) Computational Fluid Dynamics (CFD) Analysis; 10) Restrictive Orifice Design; 11) Orifice CFD Model; 12) Orifice Results; 13) Restrictive Orifice; 14) Seal Face Coning; 15) Permanent Magnet Analysis; 16) Magnetic Repulsive Force; 17) Magnetic Repulsive Test Results; 18) Spin Testing; and 19) Testing and Validation.
Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T
2016-02-01
The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.
Fabrication and test of inorganic/organic separators. [for silver zinc batteries
NASA Technical Reports Server (NTRS)
Smatko, J. S.
1974-01-01
Completion of testing and failure analysis of MDC 40 Ahr silver zinc cells containing largely inorganic separators was accomplished. The results showed that the wet stand and cycle life objectives of the silver zinc cell development program were accomplished. Building, testing and failure analysis of two plate cells employing three optimum separators selected on the basis of extensive screening tests, was performed. The best separator material as a result of these tests was doped calcium zirconate.
Analysis and Operational Feasibility of Potable Water Production
2015-09-01
III. MODELING, SIMULATION, AND TEST RESULTS ANALYSIS ..............27 A. INTRODUCTION...Regions of Study ......................57 Table 10. Drinking Water Tests ...chemicals, and coliform bacteria. Testing of the condensed water is important to ensure potability, as common tests have been conducted to ensure
Positive cell-free fetal DNA testing for trisomy 13 reveals confined placental mosaicism.
Hall, April L; Drendel, Holli M; Verbrugge, Jennifer L; Reese, Angela M; Schumacher, Katherine L; Griffith, Christopher B; Weaver, David D; Abernathy, Mary P; Litton, Christian G; Vance, Gail H
2013-09-01
We report on a case in which cell-free fetal DNA was positive for trisomy 13 most likely due to confined placental mosaicism. Cell-free fetal DNA testing analyzes DNA derived from placental trophoblast cells and can lead to incorrect results that are not representative of the fetus. We sought to confirm commercial cell-free fetal DNA testing results by chorionic villus sampling and amniocentesis. These results were followed up by postnatal chromosome analysis of cord blood and placental tissue. First-trimester cell-free fetal DNA test results were positive for trisomy 13. Cytogenetic analysis of chorionic villus sampling yielded a mosaic karyotype of 47,XY,+13[10]/46,XY[12]. G-banded analysis of amniotic fluid was normal, 46,XY. Postnatal cytogenetic analysis of cord blood was normal. Karyotyping of tissues from four quadrants of the placenta demonstrated mosaicism for trisomy 13 in two of the quadrants and a normal karyotype in the other two. Our case illustrates several important aspects of this new testing methodology: that cell-free fetal DNA may not be representative of the fetal karyotype; that follow-up with diagnostic testing of chorionic villus sampling and/or amniotic fluid for abnormal test results should be performed; and that pretest counseling regarding the full benefits, limitations, and possible testing outcomes of cell-free fetal DNA screening is important.
Design and Analysis of Tooth Impact Test Rig for Spur Gear
NASA Astrophysics Data System (ADS)
Ghazali, Wafiuddin Bin Md; Aziz, Ismail Ali Bin Abdul; Daing Idris, Daing Mohamad Nafiz Bin; Ismail, Nurazima Binti; Sofian, Azizul Helmi Bin
2016-02-01
This paper is about the design and analysis of a prototype of tooth impact test rig for spur gear. The test rig was fabricated and analysis was conducted to study its’ limitation and capabilities. The design of the rig is analysed to ensure that there will be no problem occurring during the test and reliable data can be obtained. From the result of the analysis, the maximum amount of load that can be applied, the factor of safety of the machine, the stresses on the test rig parts were determined. This is important in the design consideration of the test rig. The materials used for the fabrication of the test rig were also discussed and analysed. MSC Nastran Patran software was used to analyse the model, which was designed by using SolidWorks 2014 software. Based from the results, there were limitations found from the initial design and the test rig design needs to be improved in order for the test rig to operate properly.
Davis, Tyler; LaRocque, Karen F.; Mumford, Jeanette; Norman, Kenneth A.; Wagner, Anthony D.; Poldrack, Russell A.
2014-01-01
Multi-voxel pattern analysis (MVPA) has led to major changes in how fMRI data are analyzed and interpreted. Many studies now report both MVPA results and results from standard univariate voxel-wise analysis, often with the goal of drawing different conclusions from each. Because MVPA results can be sensitive to latent multidimensional representations and processes whereas univariate voxel-wise analysis cannot, one conclusion that is often drawn when MVPA and univariate results differ is that the activation patterns underlying MVPA results contain a multidimensional code. In the current study, we conducted simulations to formally test this assumption. Our findings reveal that MVPA tests are sensitive to the magnitude of voxel-level variability in the effect of a condition within subjects, even when the same linear relationship is coded in all voxels. We also find that MVPA is insensitive to subject-level variability in mean activation across an ROI, which is the primary variance component of interest in many standard univariate tests. Together, these results illustrate that differences between MVPA and univariate tests do not afford conclusions about the nature or dimensionality of the neural code. Instead, targeted tests of the informational content and/or dimensionality of activation patterns are critical for drawing strong conclusions about the representational codes that are indicated by significant MVPA results. PMID:24768930
Drug and alcohol testing results : 1997 annual report
DOT National Transportation Integrated Search
1998-12-01
The Drug and Alcohol Testing Results 1997 Annual Report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1997. The report covers testing results for the following drug type...
Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less
Digital tape unit test facility software
NASA Technical Reports Server (NTRS)
Jackson, J. T.
1971-01-01
Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.
Guidelines for Proof Test Analysis
NASA Technical Reports Server (NTRS)
Chell, G. G.; McClung, R. C.; Kuhlman, C. J.; Russell, D. A.; Garr, K.; Donnelly, B.
1999-01-01
These guidelines integrate state-of-the-art elastic-plastic fracture mechanics (EPFM) and proof test implementation issues into a comprehensive proof test analysis procedure in the form of a road map which identifies the types of data, fracture mechanics based parameters, and calculations needed to perform flaw screening and minimum proof load analyses of fracture critical components. Worked examples are presented to illustrate the application of the road map to proof test analysis. The state-of-the art fracture technology employed in these guidelines is based on the EPFM parameter, J, and a pictorial representation of a J fracture analysis, called the failure assessment diagram (FAD) approach. The recommended fracture technology is validated using finite element J results, and laboratory and hardware fracture test results on the nickel-based superalloy Inconel 718, the aluminum alloy 2024-T3511, and ferritic pressure vessel steels. In all cases the laboratory specimens and hardware failed by ductile mechanisms. Advanced proof test analyses involving probability analysis and multiple-cycle proof testing (MCPT) are addressed. Finally, recommendations are provided on how to account for the effects of the proof test overload on subsequent service fatigue and fracture behaviors.
Analysis of interior noise ground and flight test data for advanced turboprop aircraft applications
NASA Technical Reports Server (NTRS)
Simpson, M. A.; Tran, B. N.
1991-01-01
Interior noise ground tests conducted on a DC-9 aircraft test section are described. The objectives were to study ground test and analysis techniques for evaluating the effectiveness of interior noise control treatments for advanced turboprop aircraft, and to study the sensitivity of the ground test results to changes in various test conditions. Noise and vibration measurements were conducted under simulated advanced turboprop excitation, for two interior noise control treatment configurations. These ground measurement results were compared with results of earlier UHB (Ultra High Bypass) Demonstrator flight tests with comparable interior treatment configurations. The Demonstrator is an MD-80 test aircraft with the left JT8D engine replaced with a prototype UHB advanced turboprop engine.
Analysis of interior noise ground and flight test data for advanced turboprop aircraft applications
NASA Astrophysics Data System (ADS)
Simpson, M. A.; Tran, B. N.
1991-08-01
Interior noise ground tests conducted on a DC-9 aircraft test section are described. The objectives were to study ground test and analysis techniques for evaluating the effectiveness of interior noise control treatments for advanced turboprop aircraft, and to study the sensitivity of the ground test results to changes in various test conditions. Noise and vibration measurements were conducted under simulated advanced turboprop excitation, for two interior noise control treatment configurations. These ground measurement results were compared with results of earlier UHB (Ultra High Bypass) Demonstrator flight tests with comparable interior treatment configurations. The Demonstrator is an MD-80 test aircraft with the left JT8D engine replaced with a prototype UHB advanced turboprop engine.
Results and Analysis from Space Suit Joint Torque Testing
NASA Technical Reports Server (NTRS)
Matty, Jennifer
2010-01-01
This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.
Solar energy storage via liquid filled cans - Test data and analysis
NASA Technical Reports Server (NTRS)
Saha, H.
1978-01-01
This paper describes the design of a solar thermal storage test facility with water-filled metal cans as heat storage medium and also presents some preliminary tests results and analysis. This combination of solid and liquid mediums shows unique heat transfer and heat contents characteristics and will be well suited for use with solar air systems for space and hot water heating. The trends of the test results acquired thus far are representative of the test bed characteristics while operating in the various modes.
Ranking metrics in gene set enrichment analysis: do they matter?
Zyla, Joanna; Marczyk, Michal; Weiner, January; Polanska, Joanna
2017-05-12
There exist many methods for describing the complex relation between changes of gene expression in molecular pathways or gene ontologies under different experimental conditions. Among them, Gene Set Enrichment Analysis seems to be one of the most commonly used (over 10,000 citations). An important parameter, which could affect the final result, is the choice of a metric for the ranking of genes. Applying a default ranking metric may lead to poor results. In this work 28 benchmark data sets were used to evaluate the sensitivity and false positive rate of gene set analysis for 16 different ranking metrics including new proposals. Furthermore, the robustness of the chosen methods to sample size was tested. Using k-means clustering algorithm a group of four metrics with the highest performance in terms of overall sensitivity, overall false positive rate and computational load was established i.e. absolute value of Moderated Welch Test statistic, Minimum Significant Difference, absolute value of Signal-To-Noise ratio and Baumgartner-Weiss-Schindler test statistic. In case of false positive rate estimation, all selected ranking metrics were robust with respect to sample size. In case of sensitivity, the absolute value of Moderated Welch Test statistic and absolute value of Signal-To-Noise ratio gave stable results, while Baumgartner-Weiss-Schindler and Minimum Significant Difference showed better results for larger sample size. Finally, the Gene Set Enrichment Analysis method with all tested ranking metrics was parallelised and implemented in MATLAB, and is available at https://github.com/ZAEDPolSl/MrGSEA . Choosing a ranking metric in Gene Set Enrichment Analysis has critical impact on results of pathway enrichment analysis. The absolute value of Moderated Welch Test has the best overall sensitivity and Minimum Significant Difference has the best overall specificity of gene set analysis. When the number of non-normally distributed genes is high, using Baumgartner-Weiss-Schindler test statistic gives better outcomes. Also, it finds more enriched pathways than other tested metrics, which may induce new biological discoveries.
Pleiotropy Analysis of Quantitative Traits at Gene Level by Multivariate Functional Linear Models
Wang, Yifan; Liu, Aiyi; Mills, James L.; Boehnke, Michael; Wilson, Alexander F.; Bailey-Wilson, Joan E.; Xiong, Momiao; Wu, Colin O.; Fan, Ruzong
2015-01-01
In genetics, pleiotropy describes the genetic effect of a single gene on multiple phenotypic traits. A common approach is to analyze the phenotypic traits separately using univariate analyses and combine the test results through multiple comparisons. This approach may lead to low power. Multivariate functional linear models are developed to connect genetic variant data to multiple quantitative traits adjusting for covariates for a unified analysis. Three types of approximate F-distribution tests based on Pillai–Bartlett trace, Hotelling–Lawley trace, and Wilks’s Lambda are introduced to test for association between multiple quantitative traits and multiple genetic variants in one genetic region. The approximate F-distribution tests provide much more significant results than those of F-tests of univariate analysis and optimal sequence kernel association test (SKAT-O). Extensive simulations were performed to evaluate the false positive rates and power performance of the proposed models and tests. We show that the approximate F-distribution tests control the type I error rates very well. Overall, simultaneous analysis of multiple traits can increase power performance compared to an individual test of each trait. The proposed methods were applied to analyze (1) four lipid traits in eight European cohorts, and (2) three biochemical traits in the Trinity Students Study. The approximate F-distribution tests provide much more significant results than those of F-tests of univariate analysis and SKAT-O for the three biochemical traits. The approximate F-distribution tests of the proposed functional linear models are more sensitive than those of the traditional multivariate linear models that in turn are more sensitive than SKAT-O in the univariate case. The analysis of the four lipid traits and the three biochemical traits detects more association than SKAT-O in the univariate case. PMID:25809955
Pleiotropy analysis of quantitative traits at gene level by multivariate functional linear models.
Wang, Yifan; Liu, Aiyi; Mills, James L; Boehnke, Michael; Wilson, Alexander F; Bailey-Wilson, Joan E; Xiong, Momiao; Wu, Colin O; Fan, Ruzong
2015-05-01
In genetics, pleiotropy describes the genetic effect of a single gene on multiple phenotypic traits. A common approach is to analyze the phenotypic traits separately using univariate analyses and combine the test results through multiple comparisons. This approach may lead to low power. Multivariate functional linear models are developed to connect genetic variant data to multiple quantitative traits adjusting for covariates for a unified analysis. Three types of approximate F-distribution tests based on Pillai-Bartlett trace, Hotelling-Lawley trace, and Wilks's Lambda are introduced to test for association between multiple quantitative traits and multiple genetic variants in one genetic region. The approximate F-distribution tests provide much more significant results than those of F-tests of univariate analysis and optimal sequence kernel association test (SKAT-O). Extensive simulations were performed to evaluate the false positive rates and power performance of the proposed models and tests. We show that the approximate F-distribution tests control the type I error rates very well. Overall, simultaneous analysis of multiple traits can increase power performance compared to an individual test of each trait. The proposed methods were applied to analyze (1) four lipid traits in eight European cohorts, and (2) three biochemical traits in the Trinity Students Study. The approximate F-distribution tests provide much more significant results than those of F-tests of univariate analysis and SKAT-O for the three biochemical traits. The approximate F-distribution tests of the proposed functional linear models are more sensitive than those of the traditional multivariate linear models that in turn are more sensitive than SKAT-O in the univariate case. The analysis of the four lipid traits and the three biochemical traits detects more association than SKAT-O in the univariate case. © 2015 WILEY PERIODICALS, INC.
Integrated corridor management analysis, modeling, and simulation results for the test corridor.
DOT National Transportation Integrated Search
2008-06-01
This report documents the Integrated Corridor Management (ICM) Analysis Modeling and Simulation (AMS) tools and strategies used on a Test Corridor, presents results and lessons-learned, and documents the relative capability of AMS to support benefit-...
Simulation System of Car Crash Test in C-NCAP Analysis Based on an Improved Apriori Algorithm*
NASA Astrophysics Data System (ADS)
Xiang, LI
In order to analysis car crash test in C-NCAP, an improved algorithm is given based on Apriori algorithm in this paper. The new algorithm is implemented with vertical data layout, breadth first searching, and intersecting. It takes advantage of the efficiency of vertical data layout and intersecting, and prunes candidate frequent item sets like Apriori. Finally, the new algorithm is applied in simulation of car crash test analysis system. The result shows that the relations will affect the C-NCAP test results, and it can provide a reference for the automotive design.
Comparison of Modal Analysis Methods Applied to a Vibro-Acoustic Test Article
NASA Technical Reports Server (NTRS)
Pritchard, Jocelyn; Pappa, Richard; Buehrle, Ralph; Grosveld, Ferdinand
2001-01-01
Modal testing of a vibro-acoustic test article referred to as the Aluminum Testbed Cylinder (ATC) has provided frequency response data for the development of validated numerical models of complex structures for interior noise prediction and control. The ATC is an all aluminum, ring and stringer stiffened cylinder, 12 feet in length and 4 feet in diameter. The cylinder was designed to represent typical aircraft construction. Modal tests were conducted for several different configurations of the cylinder assembly under ambient and pressurized conditions. The purpose of this paper is to present results from dynamic testing of different ATC configurations using two modal analysis software methods: Eigensystem Realization Algorithm (ERA) and MTS IDEAS Polyreference method. The paper compares results from the two analysis methods as well as the results from various test configurations. The effects of pressurization on the modal characteristics are discussed.
NASA Technical Reports Server (NTRS)
Stricklin, R.
1981-01-01
A summary of the activities which led to defining deterioration rates of the CF6 family of engines, a description of what was learned, and an identification of means of conserving fuel based upon the program findings are presented. The program to define the deterioration levels and modes for the CF6 family of engines involved four distinct phases: analysis of inbound engine test results, analysis of airline cruise data, analysis of airline test cell data resulting from testing of refurbished engines, and inspection of engine hardware.
Thermal Design, Analysis, and Testing of the Quench Module Insert Bread Board
NASA Technical Reports Server (NTRS)
Breeding, Shawn; Khodabandeh, Julia
2002-01-01
Contents include the following: Quench Module Insert (QMI) science requirements. QMI interfaces. QMI design layout. QMI thermal analysis and design methodology. QMI bread board testing and instrumentation approach. QMI thermal probe design parameters. Design features for gradient measurement. Design features for heated zone measurements. Thermal gradient analysis results. Heated zone analysis results. Bread board thermal probe layout. QMI bread board correlation and performance. Summary and conclusions.
Pulleyblank, Ryan; Chuma, Jefter; Gilbody, Simon M; Thompson, Carl
2013-09-01
For a test to be considered useful for making treatment decisions, it is necessary that making treatment decisions based on the results of the test be a preferable strategy to making treatment decisions without the test. Decision curve analysis is a framework for assessing when a test would be expected to be useful, which integrates evidence of a test's performance characteristics (sensitivity and specificity), condition prevalence among at-risk patients, and patient preferences for treatment. We describe decision curve analysis generally and illustrate its potential through an application to tests for prodromal psychosis. Clinical psychosis is often preceded by a prodromal phase, but not all those with prodromal symptoms proceed to develop full psychosis. Patients identified as at risk for developing psychosis may be considered for proactive treatment to mitigate development of clinically defined psychosis. Tests exist to help identify those at-risk patients most likely to develop psychosis, but it is uncertain when these tests would be considered useful for making proactive treatment decisions. We apply decision curve analysis to results from a systematic review of studies investigating clinical tests for predicting the development of psychosis in at-risk populations, and present resulting decision curves that illustrate when the tests may be expected to be useful for making proactive treatment decisions.
Zhang, L; Jin, C; Jiang, Z; Tang, T; Jiang, Y; Pan, P L
2017-09-10
Objective: To compare the bio-equivalence among commercial HIV-1 viral load tests, including EasyQ HIV-1 v2.0 (EasyQ) from bioMerieux NucliSens of France; VERSANT HIV-1 RNA 3.0 assay (bDNA) from Siemens Healthcare Diagnostics of USA; COBAS AmpliPrep/COBAS TaqMan HIV-1 test (Taqman) from Roche Molecular Diagnosis of USA; Abbott Real Time HIV-1 Kit (M2000) from Abbott Molecular of USA and two domestic HIV-1 viral load test kits (domestic kit) from DaAn Gene Company of Sun Yat-Sen University and Liaoning Bio-Pharmaceutical company of Northeast pharmaceutical group, by using proficiency test results in China from 2013 to 2015. Methods: A total of 2 954 proficiency test results, obtained from 22 positive samples of 6 proficiency tests in 155 laboratories conducted by China CDC were analyzed during 2013-2015. The results from each sample were first logarithmic transformed and then grouped according to the method used, the mean value of logarithmic results was calculated. Subsequently, 22 clusters of mean values were analyzed by Bland-Altman analysis for the consistency, and linear regression analysis for the interdependency. Results: The results indicated that, by taking Taqman as the reference, EasyQ, M2000, bDNA and domestic kit had good consistency (90 % -100 % ) and interdependency. Conclusion: All the viral load tests were bio-equivalent. Moreover, according to the conversion formula derived from domestic proficiency test results, all the viral load results could be converted, which is critical for epidemiological analysis.
NASA Technical Reports Server (NTRS)
Ray, Ronald J.
1994-01-01
New flight test maneuvers and analysis techniques for evaluating the dynamic response of in-flight thrust models during throttle transients have been developed and validated. The approach is based on the aircraft and engine performance relationship between thrust and drag. Two flight test maneuvers, a throttle step and a throttle frequency sweep, were developed and used in the study. Graphical analysis techniques, including a frequency domain analysis method, were also developed and evaluated. They provide quantitative and qualitative results. Four thrust calculation methods were used to demonstrate and validate the test technique. Flight test applications on two high-performance aircraft confirmed the test methods as valid and accurate. These maneuvers and analysis techniques were easy to implement and use. Flight test results indicate the analysis techniques can identify the combined effects of model error and instrumentation response limitations on the calculated thrust value. The methods developed in this report provide an accurate approach for evaluating, validating, or comparing thrust calculation methods for dynamic flight applications.
Drug and alcohol testing results 1998 annual report
DOT National Transportation Integrated Search
1999-12-01
The Drug and Alcohol Testing Results 1998 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1998. The report covers results for the following drug types: marijuana ...
Drug and alcohol testing results 2000 annual report
DOT National Transportation Integrated Search
2001-12-01
The Drug and Alcohol Testing Results 2000 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United State during 2000. The report covers results for the following drug types: marijuana (...
Drug and alcohol testing results 1999 annual report
DOT National Transportation Integrated Search
2000-12-01
The Drug and Alcohol Testing Results 1999 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1999. The report covers results for the following drug types: marijuana ...
Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.
Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S
2014-06-01
A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.
SIMS prototype system 3 test results: Engineering analysis
NASA Technical Reports Server (NTRS)
1978-01-01
The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.
Helicopter noise analysis : round-robin test
DOT National Transportation Integrated Search
1981-08-01
This report documents the results of an international round robin test on the analysis of helicopter noise. Digital spectral noise data of a 3.5-second simulated helicopter flyover and identical analog test tapes containing helicopter noise data, ref...
Workarounds and Test Results Follow-up in Electronic Health Record-Based Primary Care
Menon, Shailaja; Murphy, Daniel R.; Singh, Hardeep; Meyer, Ashley N. D.
2016-01-01
Summary Background Electronic health records (EHRs) have potential to facilitate reliable communication and follow-up of test results. However, limitations in EHR functionality remain, leading practitioners to use workarounds while managing test results. Workarounds can lead to patient safety concerns and signify indications as to how to build better EHR systems that meet provider needs. Objective To understand why primary care practitioners (PCPs) use workarounds to manage test results by analyzing data from a previously conducted national cross-sectional survey on test result management. Methods We conducted a secondary data analysis of quantitative and qualitative data from a national survey of PCPs practicing in the Department of Veterans Affairs (VA) and explored the use of workarounds in test results management. We used multivariate logistic regression analysis to examine the association between key sociotechnical factors that could affect test results follow-up (e.g., both technology-related and those unrelated to technology, such as organizational support for patient notification) and workaround use. We conducted a qualitative content analysis of free text survey data to examine reasons for use of workarounds. Results Of 2554 survey respondents, 1104 (43%) reported using workarounds related to test results management. Of these 1028 (93%) described the type of workaround they were using; 719 (70%) reported paper-based methods, while 230 (22%) used a combination of paper- and computer-based workarounds. Primary care practitioners who self-reported limited administrative support to help them notify patients of test results or described an instance where they personally (or a colleague) missed results, were more likely to use workarounds (p=0.02 and p=0.001, respectively). Qualitative analysis identified three main reasons for workaround use: 1) as a memory aid, 2) for improved efficiency and 3) for facilitating internal and external care coordination. Conclusion Workarounds to manage EHR-based test results are common, and their use results from unmet provider information management needs. Future EHRs and the respective work systems around them need to evolve to meet these needs. PMID:27437060
Posttest analysis of the FFTF inherent safety tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Padilla, A. Jr.; Claybrook, S.W.
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactormore » and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest analyses. The purpose of this paper is to present the results of the posttest analysis of the 1986 FFTF inherent safety tests using the SASSYS code.« less
ERIC Educational Resources Information Center
Greenlaw, M. Jean; Moore, David
A review of literature by reading authorities identified seven criteria necessary for meaningful research about reading readiness tests. These criteria were then used in analysis of 15 research studies dealing with the "Metropolitan Readiness Test" and first grade reading achievement. Five major findings resulted from this analysis:…
Pretest uncertainty analysis for chemical rocket engine tests
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.
1987-01-01
A parametric pretest uncertainty analysis has been performed for a chemical rocket engine test at a unique 1000:1 area ratio altitude test facility. Results from the parametric study provide the error limits required in order to maintain a maximum uncertainty of 1 percent on specific impulse. Equations used in the uncertainty analysis are presented.
Riley, Richard D; Ahmed, Ikhlaaq; Debray, Thomas P A; Willis, Brian H; Noordzij, J Pieter; Higgins, Julian P T; Deeks, Jonathan J
2015-06-15
Following a meta-analysis of test accuracy studies, the translation of summary results into clinical practice is potentially problematic. The sensitivity, specificity and positive (PPV) and negative (NPV) predictive values of a test may differ substantially from the average meta-analysis findings, because of heterogeneity. Clinicians thus need more guidance: given the meta-analysis, is a test likely to be useful in new populations, and if so, how should test results inform the probability of existing disease (for a diagnostic test) or future adverse outcome (for a prognostic test)? We propose ways to address this. Firstly, following a meta-analysis, we suggest deriving prediction intervals and probability statements about the potential accuracy of a test in a new population. Secondly, we suggest strategies on how clinicians should derive post-test probabilities (PPV and NPV) in a new population based on existing meta-analysis results and propose a cross-validation approach for examining and comparing their calibration performance. Application is made to two clinical examples. In the first example, the joint probability that both sensitivity and specificity will be >80% in a new population is just 0.19, because of a low sensitivity. However, the summary PPV of 0.97 is high and calibrates well in new populations, with a probability of 0.78 that the true PPV will be at least 0.95. In the second example, post-test probabilities calibrate better when tailored to the prevalence in the new population, with cross-validation revealing a probability of 0.97 that the observed NPV will be within 10% of the predicted NPV. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.
Mathematics Placement Test: Typical Results with Unexpected Outcomes
ERIC Educational Resources Information Center
Ingalls, Victoria
2011-01-01
Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…
Caudullo, Giorgio; Caruso, Valentina; Cappella, Annalisa; Sguazza, Emanuela; Mazzarelli, Debora; Amadasi, Alberto; Cattaneo, Cristina
2017-01-01
When forensic pathologists and anthropologists have to deal with the evaluation of the post-mortem interval (PMI) in skeletal remains, luminol testing is frequently performed as a preliminary screening method. However, the repeatability of this test on the same bone, as well as comparative studies on different bones of the same individual, has never been performed. Therefore, with the aim of investigating the influence that different types of bones may exert on the response to the luminol test, the present study analysed three different skeletal elements (femoral diaphysis, vertebra and cranial vault), gathered from ten recent exhumed skeletons (all with a 20-year PMI). The analysis was performed twice on the same bone after 2 months: the analysis at time 0 concerned the whole bone, whereas the second concerned only a part of the same bone taken during the first test (which already had been broken). The overall results showed different responses, depending on the type of bone and on the integrity of the samples. Negative results at the first analysis (6.6% out of the total of samples) are consistent with what is reported in the literature, whilst at the second analysis, the increase of about 20% of false-negative results highlights that the luminol test ought to be performed with caution in case of broken bones or elements which are taphonomically altered. Results have thus proven that the exposition to environmental agents might result in haemoglobin (Hb) loss, as detected even after only 2 months. The study also focused on the crucial issue of the type of bone subjected to testing, remarking the suitability of the femoral diaphysis (100% of positive responses at the first analysis vs only 18% of false-negative results at the second test, corresponding to 5% of total false-negative results) as opposed to other bone elements that showed a low yield. In particular, the cranial vault gave poor results, with 40% of discrepancy between results from the two analyses, which suggests caution in choosing the type of bone sample to test. In conclusion, luminol testing should be used with caution on bones different from long bones or on non-intact bones.
Integrated Data Collection Analysis (IDCA) Program - Statistical Analysis of RDX Standard Data Sets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
2015-10-30
The Integrated Data Collection Analysis (IDCA) program is conducting a Proficiency Test for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard. The material was tested as a well-characterized standard several times during the proficiency study to assess differences among participants and the range of results that may arise for well-behaved explosive materials. The analyses show that there are detectable differences among the results from IDCA participants. While these differences are statisticallymore » significant, most of them can be disregarded for comparison purposes to assess potential variability when laboratories attempt to measure identical samples using methods assumed to be nominally the same. The results presented in this report include the average sensitivity results for the IDCA participants and the ranges of values obtained. The ranges represent variation about the mean values of the tests of between 26% and 42%. The magnitude of this variation is attributed to differences in operator, method, and environment as well as the use of different instruments that are also of varying age. The results appear to be a good representation of the broader safety testing community based on the range of methods, instruments, and environments included in the IDCA Proficiency Test.« less
Scaled Tank Test Design and Results for the Aquantis 2.5 MW Ocean Current Generation Device
Swales, Henry; Kils, Ole; Coakley, David B.; Sites, Eric; Mayer, Tyler
2015-06-03
Aquantis 2.5 MW Ocean Current Generation Device, Tow Tank Dynamic Rig Structural Analysis Results. This is the detailed documentation for scaled device testing in a tow tank, including models, drawings, presentations, cost of energy analysis, and structural analysis. This dataset also includes specific information on drivetrain, roller bearing, blade fabrication, mooring, and rotor characteristics.
NASA Technical Reports Server (NTRS)
Phillips, E. P.
1993-01-01
A second experimental Round Robin on the measurement of the crack opening load in fatigue crack growth tests has been completed by the ASTM Task Group E24.04.04 on Crack Closure Measurement and Analysis. Fourteen laboratories participated in the testing of aluminum alloy compact tension specimens. Opening-load measurements were made at three crack lengths during constant Delta K, constant stress ratio tests by most of the participants. Four participants made opening-load measurements during threshold tests. All opening-load measurements were based on the analysis of specimens compliance behavior, where the displacement/strain was measured either at the crack mouth or the mid-height back face location. The Round Robin data were analyzed for opening load using two non-subjective analysis methods: the compliance offset and the correlation coefficient methods. The scatter in the opening load results was significantly reduced when some of the results were excluded from the analysis population based on an accept/reject criterion for raw data quality. The compliance offset and correlation coefficient opening load analysis methods produced similar results for data populations that had been screened to eliminate poor quality data.
Chandra X-ray Center Science Data Systems Regression Testing of CIAO
NASA Astrophysics Data System (ADS)
Lee, N. P.; Karovska, M.; Galle, E. C.; Bonaventura, N. R.
2011-07-01
The Chandra Interactive Analysis of Observations (CIAO) is a software system developed for the analysis of Chandra X-ray Observatory observations. An important component of a successful CIAO release is the repeated testing of the tools across various platforms to ensure consistent and scientifically valid results. We describe the procedures of the scientific regression testing of CIAO and the enhancements made to the testing system to increase the efficiency of run time and result validation.
Cappella, Annalisa; Gibelli, Daniele; Muccino, Enrico; Scarpulla, Valentina; Cerutti, Elisa; Caruso, Valentina; Sguazza, Emanuela; Mazzarelli, Debora; Cattaneo, Cristina
2015-01-27
When estimating post-mortem interval (PMI) in forensic anthropology, the only method able to give an unambiguous result is the analysis of C-14, although the procedure is expensive. Other methods, such as luminol tests and histological analysis, can be performed as preliminary investigations and may allow the operators to gain a preliminary indication concerning PMI, but they lack scientific verification, although luminol testing has been somewhat more accredited in the past few years. Such methods in fact may provide some help as they are inexpensive and can give a fast response, especially in the phase of preliminary investigations. In this study, 20 court cases of human skeletonized remains were dated by the C-14 method. For two cases, results were chronologically set after the 1950s; for one case, the analysis was not possible technically. The remaining 17 cases showed an archaeological or historical collocation. The same bone samples were also screened with histological examination and with the luminol test. Results showed that only four cases gave a positivity to luminol and a high Oxford Histology Index (OHI) score at the same time: among these, two cases were dated as recent by the radiocarbon analysis. Thus, only two false-positive results were given by the combination of these methods and no false negatives. Thus, the combination of two qualitative methods (luminol test and microscopic analysis) may represent a promising solution to cases where many fragments need to be quickly tested.
Comparison of NASTRAN analysis with ground vibration results of UH-60A NASA/AEFA test configuration
NASA Technical Reports Server (NTRS)
Idosor, Florentino; Seible, Frieder
1990-01-01
Preceding program flight tests, a ground vibration test and modal test analysis of a UH-60A Black Hawk helicopter was conducted by Sikorsky Aircraft to complement the UH-60A test plan and NASA/ARMY Modern Technology Rotor Airloads Program. The 'NASA/AEFA' shake test configuration was tested for modal frequencies and shapes and compared with its NASTRAN finite element model counterpart to give correlative results. Based upon previous findings, significant differences in modal data existed and were attributed to assumptions regarding the influence of secondary structure contributions in the preliminary NASTRAN modeling. An analysis of an updated finite element model including several secondary structural additions has confirmed that the inclusion of specific secondary components produces a significant effect on modal frequency and free-response shapes and improves correlations at lower frequencies with shake test data.
NASA Contractor Report: Guidelines for Proof Test Analysis
NASA Technical Reports Server (NTRS)
Chell, G. G.; McClung, R. C.; Kuhlman, C. J.; Russell, D. A.; Garr, K.; Donnelly, B.
1997-01-01
These Guidelines integrate state-of-the-art Elastic-Plastic Fracture Mechanics (EPFM) and proof test implementation issues into a comprehensive proof test analysis procedure in the form of a Road Map which identifies the types of data, fracture mechanics based parameters, and calculations needed to perform flaw screening and minimum proof load analyses of fracture critical components. Worked examples are presented to illustrate the application of the Road Map to proof test analysis. The state-of-the-art fracture technology employed in these Guidelines is based on the EPFM parameter, J, and a pictorial representation of a J fracture analysis, called the Failure Assessment Diagram (FAD) approach. The recommended fracture technology is validated using finite element J results, and laboratory and hardware fracture test results on the nickel-based superalloy IN-718, the aluminum alloy 2024-T351 1, and ferritic pressure vessel steels. In all cases the laboratory specimens and hardware failed by ductile mechanisms. Advanced proof test analyses involving probability analysis and Multiple Cycle Proof Testing (MCPT) are addressed. Finally, recommendations are provided on to how to account for the effects of the proof test overload on subsequent service fatigue and fracture behaviors.
Verification and Validation of the General Mission Analysis Tool (GMAT)
NASA Technical Reports Server (NTRS)
Hughes, Steven P.; Qureshi, Rizwan H.; Cooley, D. Steven; Parker, Joel J. K.; Grubb, Thomas G.
2014-01-01
This paper describes the processes and results of Verification and Validation (V&V) efforts for the General Mission Analysis Tool (GMAT). We describe the test program and environments, the tools used for independent test data, and comparison results. The V&V effort produced approximately 13,000 test scripts that are run as part of the nightly buildtest process. In addition, we created approximately 3000 automated GUI tests that are run every two weeks. Presenting all test results are beyond the scope of a single paper. Here we present high-level test results in most areas, and detailed test results for key areas. The final product of the V&V effort presented in this paper was GMAT version R2013a, the first Gold release of the software with completely updated documentation and greatly improved quality. Release R2013a was the staging release for flight qualification performed at Goddard Space Flight Center (GSFC) ultimately resulting in GMAT version R2013b.
Relativity Concept Inventory: Development, Analysis, and Results
ERIC Educational Resources Information Center
Aslanides, J. S.; Savage, C. M.
2013-01-01
We report on a concept inventory for special relativity: the development process, data analysis methods, and results from an introductory relativity class. The Relativity Concept Inventory tests understanding of relativistic concepts. An unusual feature is confidence testing for each question. This can provide additional information; for example,…
77 FR 37717 - Electrical Cable Test Results and Analysis During Fire Exposure
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... Fire Exposure AGENCY: Nuclear Regulatory Commission. ACTION: Draft NUREG; request for comment. SUMMARY...-2128, ``Electrical Cable Test Results and Analysis during Fire Exposure (ELECTRA-FIRE), A Consolidation of the Three Major Fire-Induced Circuit and Cable Failure Experiments Performed between 2001 and 2011...
Using Dynamic Sensitivity Analysis to Assess Testability
NASA Technical Reports Server (NTRS)
Voas, Jeffrey; Morell, Larry; Miller, Keith
1990-01-01
This paper discusses sensitivity analysis and its relationship to random black box testing. Sensitivity analysis estimates the impact that a programming fault at a particular location would have on the program's input/output behavior. Locations that are relatively \\"insensitive" to faults can render random black box testing unlikely to uncover programming faults. Therefore, sensitivity analysis gives new insight when interpreting random black box testing results. Although sensitivity analysis is computationally intensive, it requires no oracle and no human intervention.
NASA Technical Reports Server (NTRS)
Jeng, Frank F.
2007-01-01
Development of analysis guidelines for Exploration Life Support (ELS) technology tests was completed. The guidelines were developed based on analysis experiences gained from supporting Environmental Control and Life Support System (ECLSS) technology development in air revitalization systems and water recovery systems. Analyses are vital during all three phases of the ELS technology test: pre-test, during test and post test. Pre-test analyses of a test system help define hardware components, predict system and component performances, required test duration, sampling frequencies of operation parameters, etc. Analyses conducted during tests could verify the consistency of all the measurements and the performance of the test system. Post test analyses are an essential part of the test task. Results of post test analyses are an important factor in judging whether the technology development is a successful one. In addition, development of a rigorous model for a test system is an important objective of any new technology development. Test data analyses, especially post test data analyses, serve to verify the model. Test analyses have supported development of many ECLSS technologies. Some test analysis tasks in ECLSS technology development are listed in the Appendix. To have effective analysis support for ECLSS technology tests, analysis guidelines would be a useful tool. These test guidelines were developed based on experiences gained through previous analysis support of various ECLSS technology tests. A comment on analysis from an experienced NASA ECLSS manager (1) follows: "Bad analysis was one that bent the test to prove that the analysis was right to begin with. Good analysis was one that directed where the testing should go and also bridged the gap between the reality of the test facility and what was expected on orbit."
NASA Technical Reports Server (NTRS)
Gates, R. M.; Williams, J. E.
1974-01-01
Results are given of analytical studies performed in support of the design, implementation, checkout and use of NASA's dynamic docking test system (DDTS). Included are analyses of simulator components, a list of detailed operational test procedures, a summary of simulator performance, and an analysis and comparison of docking dynamics and loads obtained by test and analysis.
Meta-analysis of gene-level associations for rare variants based on single-variant statistics.
Hu, Yi-Juan; Berndt, Sonja I; Gustafsson, Stefan; Ganna, Andrea; Hirschhorn, Joel; North, Kari E; Ingelsson, Erik; Lin, Dan-Yu
2013-08-08
Meta-analysis of genome-wide association studies (GWASs) has led to the discoveries of many common variants associated with complex human diseases. There is a growing recognition that identifying "causal" rare variants also requires large-scale meta-analysis. The fact that association tests with rare variants are performed at the gene level rather than at the variant level poses unprecedented challenges in the meta-analysis. First, different studies may adopt different gene-level tests, so the results are not compatible. Second, gene-level tests require multivariate statistics (i.e., components of the test statistic and their covariance matrix), which are difficult to obtain. To overcome these challenges, we propose to perform gene-level tests for rare variants by combining the results of single-variant analysis (i.e., p values of association tests and effect estimates) from participating studies. This simple strategy is possible because of an insight that multivariate statistics can be recovered from single-variant statistics, together with the correlation matrix of the single-variant test statistics, which can be estimated from one of the participating studies or from a publicly available database. We show both theoretically and numerically that the proposed meta-analysis approach provides accurate control of the type I error and is as powerful as joint analysis of individual participant data. This approach accommodates any disease phenotype and any study design and produces all commonly used gene-level tests. An application to the GWAS summary results of the Genetic Investigation of ANthropometric Traits (GIANT) consortium reveals rare and low-frequency variants associated with human height. The relevant software is freely available. Copyright © 2013 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.
Test/semi-empirical analysis of a carbon/epoxy fabric stiffened panel
NASA Technical Reports Server (NTRS)
Spier, E. E.; Anderson, J. A.
1990-01-01
The purpose of this work-in-progress is to present a semi-empirical analysis method developed to predict the buckling and crippling loads of carbon/epoxy fabric blade stiffened panels in compression. This is a hand analysis method comprised of well known, accepted techniques, logical engineering judgements, and experimental data that results in conservative solutions. In order to verify this method, a stiffened panel was fabricated and tested. Both the best and analysis results are presented.
Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report
NASA Technical Reports Server (NTRS)
Roberts, Eileen; Villani, James A.; Ritter, Paul
1997-01-01
This document is the Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report. The purpose of this document is to present the results of the QRS unit and system tests in support of the ASAC QRS development effort. This document contains an overview of the project background and scope, defines the QRS system and presents the additions made to the QRS this year, explains the assumptions, constraints, and approach used to conduct QRS Unit and System Testing, and presents the schedule used to perform QRS Testing. The document also presents an overview of the Logistics Management Institute (LMI) Test Facility and testing environment and summarizes the QRS Unit and System Test effort and results.
NASA Technical Reports Server (NTRS)
Bruce, Walter E., III; Mesick, Nathaniel J.; Ferlemann, Paul G.; Siemers, Paul M., III; DelCorso, Joseph A.; Hughes, Stephen J.; Tobin, Steven A.; Kardell, Matthew P.
2012-01-01
Flexible TPS development involves ground testing and analysis necessary to characterize performance of the FTPS candidates prior to flight testing. This paper provides an overview of the analysis and ground testing efforts performed over the last year at the NASA Langley Research Center and in the Boeing Large-Core Arc Tunnel (LCAT). In the LCAT test series, material layups were subjected to aerothermal loads commensurate with peak re-entry conditions enveloping a range of HIAD mission trajectories. The FTPS layups were tested over a heat flux range from 20 to 50 W/cm with associated surface pressures of 3 to 8 kPa. To support the testing effort a significant redesign of the existing shear (wedge) model holder from previous testing efforts was undertaken to develop a new test technique for supporting and evaluating the FTPS in the high-temperature, arc jet flow. Since the FTPS test samples typically experience a geometry change during testing, computational fluid dynamic (CFD) models of the arc jet flow field and test model were developed to support the testing effort. The CFD results were used to help determine the test conditions experienced by the test samples as the surface geometry changes. This paper includes an overview of the Boeing LCAT facility, the general approach for testing FTPS, CFD analysis methodology and results, model holder design and test methodology, and selected thermal results of several FTPS layups.
Response analysis of an automobile shipping container
NASA Technical Reports Server (NTRS)
Hua, L.; Lee, S. H.; Johnstone, B.
1973-01-01
The design and development of automobile shipping containers to reduce enroute damage are discussed. Vibration tests were conducted to determine the system structural integrity. A dynamic analysis was made using NASTRAN and the results of the test and the analysis are compared.
NASA Astrophysics Data System (ADS)
Hart, D. M.; Merchant, B. J.; Abbott, R. E.
2012-12-01
The Component Evaluation project at Sandia National Laboratories supports the Ground-based Nuclear Explosion Monitoring program by performing testing and evaluation of the components that are used in seismic and infrasound monitoring systems. In order to perform this work, Component Evaluation maintains a testing facility called the FACT (Facility for Acceptance, Calibration, and Testing) site, a variety of test bed equipment, and a suite of software tools for analyzing test data. Recently, Component Evaluation has successfully integrated several improvements to its software analysis tools and test bed equipment that have substantially improved our ability to test and evaluate components. The software tool that is used to analyze test data is called TALENT: Test and AnaLysis EvaluatioN Tool. TALENT is designed to be a single, standard interface to all test configuration, metadata, parameters, waveforms, and results that are generated in the course of testing monitoring systems. It provides traceability by capturing everything about a test in a relational database that is required to reproduce the results of that test. TALENT provides a simple, yet powerful, user interface to quickly acquire, process, and analyze waveform test data. The software tool has also been expanded recently to handle sensors whose output is proportional to rotation angle, or rotation rate. As an example of this new processing capability, we show results from testing the new ATA ARS-16 rotational seismometer. The test data was collected at the USGS ASL. Four datasets were processed: 1) 1 Hz with increasing amplitude, 2) 4 Hz with increasing amplitude, 3) 16 Hz with increasing amplitude and 4) twenty-six discrete frequencies between 0.353 Hz to 64 Hz. The results are compared to manufacture-supplied data sheets.
Results of the GCMS Effluent Gas Analysis for the Brine Processing Test
NASA Technical Reports Server (NTRS)
Delzeit, Lance; Lee, Jeffrey; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Harris, Linden
2015-01-01
The effluent gas for the Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB) were analyzed using Headspace GCMS Analysis in the recent AES FY14 Brine Processing Test. The results from the analysis describe the number and general chemical species of the chemicals produced. Comparisons were also made between the different chromatograms for each system, and an explanation of the differences in the results is reported.
Testing and analysis of flat and curved panels with multiple cracks
NASA Technical Reports Server (NTRS)
Broek, David; Jeong, David Y.; Thomson, Douglas
1994-01-01
An experimental and analytical investigation of multiple cracking in various types of test specimens is described in this paper. The testing phase is comprised of a flat unstiffened panel series and curved stiffened and unstiffened panel series. The test specimens contained various configurations for initial damage. Static loading was applied to these specimens until ultimate failure, while loads and crack propagation were recorded. This data provides the basis for developing and validating methodologies for predicting linkup of multiple cracks, progression to failure, and overall residual strength. The results from twelve flat coupon and ten full scale curved panel tests are presented. In addition, an engineering analysis procedure was developed to predict multiple crack linkup. Reasonable agreement was found between predictions and actual test results for linkup and residual strength for both flat and curved panels. The results indicate that an engineering analysis approach has the potential to quantitatively assess the effect of multiple cracks in the arrest capability of an aircraft fuselage structure.
Orbit Transfer Vehicle (OTV) engine, phase A study. Volume 2: Study
NASA Technical Reports Server (NTRS)
Mellish, J. A.
1979-01-01
The hydrogen oxygen engine used in the orbiter transfer vehicle is described. The engine design is analyzed and minimum engine performance and man rating requirements are discussed. Reliability and safety analysis test results are presented and payload, risk and cost, and engine installation parameters are defined. Engine tests were performed including performance analysis, structural analysis, thermal analysis, turbomachinery analysis, controls analysis, and cycle analysis.
Explanation of Two Anomalous Results in Statistical Mediation Analysis
ERIC Educational Resources Information Center
Fritz, Matthew S.; Taylor, Aaron B.; MacKinnon, David P.
2012-01-01
Previous studies of different methods of testing mediation models have consistently found two anomalous results. The first result is elevated Type I error rates for the bias-corrected and accelerated bias-corrected bootstrap tests not found in nonresampling tests or in resampling tests that did not include a bias correction. This is of special…
[Optimization of cluster analysis based on drug resistance profiles of MRSA isolates].
Tani, Hiroya; Kishi, Takahiko; Gotoh, Minehiro; Yamagishi, Yuka; Mikamo, Hiroshige
2015-12-01
We examined 402 methicillin-resistant Staphylococcus aureus (MRSA) strains isolated from clinical specimens in our hospital between November 19, 2010 and December 27, 2011 to evaluate the similarity between cluster analysis of drug susceptibility tests and pulsed-field gel electrophoresis (PFGE). The results showed that the 402 strains tested were classified into 27 PFGE patterns (151 subtypes of patterns). Cluster analyses of drug susceptibility tests with the cut-off distance yielding a similar classification capability showed favorable results--when the MIC method was used, and minimum inhibitory concentration (MIC) values were used directly in the method, the level of agreement with PFGE was 74.2% when 15 drugs were tested. The Unweighted Pair Group Method with Arithmetic mean (UPGMA) method was effective when the cut-off distance was 16. Using the SIR method in which susceptible (S), intermediate (I), and resistant (R) were coded as 0, 2, and 3, respectively, according to the Clinical and Laboratory Standards Institute (CLSI) criteria, the level of agreement with PFGE was 75.9% when the number of drugs tested was 17, the method used for clustering was the UPGMA, and the cut-off distance was 3.6. In addition, to assess the reproducibility of the results, 10 strains were randomly sampled from the overall test and subjected to cluster analysis. This was repeated 100 times under the same conditions. The results indicated good reproducibility of the results, with the level of agreement with PFGE showing a mean of 82.0%, standard deviation of 12.1%, and mode of 90.0% for the MIC method and a mean of 80.0%, standard deviation of 13.4%, and mode of 90.0% for the SIR method. In summary, cluster analysis for drug susceptibility tests is useful for the epidemiological analysis of MRSA.
Rolling-Element Fatigue Testing and Data Analysis - A Tutorial
NASA Technical Reports Server (NTRS)
Vlcek, Brian L.; Zaretsky, Erwin V.
2011-01-01
In order to rank bearing materials, lubricants and other design variables using rolling-element bench type fatigue testing of bearing components and full-scale rolling-element bearing tests, the investigator needs to be cognizant of the variables that affect rolling-element fatigue life and be able to maintain and control them within an acceptable experimental tolerance. Once these variables are controlled, the number of tests and the test conditions must be specified to assure reasonable statistical certainty of the final results. There is a reasonable correlation between the results from elemental test rigs with those results obtained with full-scale bearings. Using the statistical methods of W. Weibull and L. Johnson, the minimum number of tests required can be determined. This paper brings together and discusses the technical aspects of rolling-element fatigue testing and data analysis as well as making recommendations to assure quality and reliable testing of rolling-element specimens and full-scale rolling-element bearings.
Cawthon, Stephanie; Leppo, Rachel
2013-01-01
The authors conducted a qualitative meta-analysis of the research on assessment accommodations for students who are deaf or hard of hearing. There were 16 identified studies that analyzed the impact of factors related to student performance on academic assessments across different educational settings, content areas, and types of assessment accommodations. The meta-analysis found that the results of analyses of group effects of accommodated versus unaccommodated test formats are often not significant, test-level factors exist that can affect how students perceive the assessments, and differences exist in how test items function across different conditions. Student-level factors, including educational context and academic proficiency, influence accommodations' role in assessment processes. The results of this analysis highlight the complexity of and intersections between student-level factors, test-level factors, and larger policy contexts. Findings are discussed within the context of larger changes in academic assessment, including computer-based administration and high-stakes testing.
Analysis of 2004 Round Robin Tests 1 and 4 Data
NASA Technical Reports Server (NTRS)
Hirsch, David; Beeson, Harold
2005-01-01
An analysis of 2004 round robin tests 1 and 4 data is presented. Test 1 burn length test results include: 1) Kydex, WSTF No. 04-38645 25.9% O2 @ 14.3 psia; 2) Kydex, 30% O2 @ 10.2 psia; 3) Royal Blue Cotton, Flame Resistant (WST No. 04-38644) 30% O2 @ 10.2 psia; and 4) Silicone 20.9% O2 @ 14.7 psia. Test 4 burn length test results include: 1) Raychem Electrical Wire, MIL M22759/32-20-9 30% O2 @ 10.2 psia; and 2) Raychem Electrical Wire, MIL M81044/12-20-9 20.9% O2 @ 14.7 psia.
Savasoglu, Kaan; Payzin, Kadriye Bahriye; Ozdemirkiran, Fusun; Berber, Belgin
2015-08-01
To determine the use of the Quantitative Real Time PCR (RQ-PCR) assay follow-up with Chronic Myeloid Leukemia (CML) patients. Cross-sectional observational. Izmir Ataturk Education and Research Hospital, Izmir, Turkey, from 2009 to 2013. Cytogenetic, FISH, RQ-PCR test results from 177 CMLpatients' materials selected between 2009 - 2013 years was set up for comparison analysis. Statistical analysis was performed to compare between FISH, karyotype and RQ-PCR results of the patients. Karyotyping and FISH specificity and sensitivity rates determined by ROC analysis compared with RQ-PCR results. Chi-square test was used to compare test failure rates. Sensitivity and specificity values were determined for karyotyping 17.6 - 98% (p=0.118, p > 0.05) and for FISH 22.5 - 96% (p=0.064, p > 0.05) respectively. FISH sensitivity was slightly higher than karyotyping but there was calculated a strong correlation between them (p < 0.001). RQ-PCR test failure rate did not correlate with other two tests (p > 0.05); however, karyotyping and FISH test failure rate was statistically significant (p < 0.001). Besides, the situation needed for karyotype analysis, RQ-PCR assay can be used alone in the follow-up of CMLdisease.
Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima
2014-01-01
Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212
Sharp, T G
1984-02-01
The study was designed to determine whether any one of seven selected variables or a combination of the variables is predictive of performance on the State Board Test Pool Examination. The selected variables studied were: high school grade point average (HSGPA), The University of Tennessee, Knoxville, College of Nursing grade point average (GPA), and American College Test Assessment (ACT) standard scores (English, ENG; mathematics, MA; social studies, SS; natural sciences, NSC; composite, COMP). Data utilized were from graduates of the baccalaureate program of The University of Tennessee, Knoxville, College of Nursing from 1974 through 1979. The sample of 322 was selected from a total population of 572. The Statistical Analysis System (SAS) was designed to accomplish analysis of the predictive relationship of each of the seven selected variables to State Board Test Pool Examination performance (result of pass or fail), a stepwise discriminant analysis was designed for determining the predictive relationship of the strongest combination of the independent variables to overall State Board Test Pool Examination performance (result of pass or fail), and stepwise multiple regression analysis was designed to determine the strongest predictive combination of selected variables for each of the five subexams of the State Board Test Pool Examination. The selected variables were each found to be predictive of SBTPE performance (result of pass or fail). The strongest combination for predicting SBTPE performance (result of pass or fail) was found to be GPA, MA, and NSC.
A Passive Earth-Entry Capsule for Mars Sample Return
NASA Technical Reports Server (NTRS)
Mitcheltree, Robert A.; Kellas, Sotiris
1999-01-01
A combination of aerodynamic analysis and testing, aerothermodynamic analysis, structural analysis and testing, impact analysis and testing, thermal analysis, ground characterization tests, configuration packaging, and trajectory simulation are employed to determine the feasibility of an entirely passive Earth entry capsule for the Mars Sample Return mission. The design circumvents the potential failure modes of a parachute terminal descent system by replacing that system with passive energy absorbing material to cushion the Mars samples during ground impact. The suggested design utilizes a spherically blunted 45-degree half-angle cone forebody with an ablative heat shield. The primary structure is a hemispherical, composite sandwich enclosing carbon foam energy absorbing material. Though no demonstration test of the entire system is included, results of the tests and analysis presented indicate that the design is a viable option for the Mars Sample Return Mission.
Improved Test Planning and Analysis Through the Use of Advanced Statistical Methods
NASA Technical Reports Server (NTRS)
Green, Lawrence L.; Maxwell, Katherine A.; Glass, David E.; Vaughn, Wallace L.; Barger, Weston; Cook, Mylan
2016-01-01
The goal of this work is, through computational simulations, to provide statistically-based evidence to convince the testing community that a distributed testing approach is superior to a clustered testing approach for most situations. For clustered testing, numerous, repeated test points are acquired at a limited number of test conditions. For distributed testing, only one or a few test points are requested at many different conditions. The statistical techniques of Analysis of Variance (ANOVA), Design of Experiments (DOE) and Response Surface Methods (RSM) are applied to enable distributed test planning, data analysis and test augmentation. The D-Optimal class of DOE is used to plan an optimally efficient single- and multi-factor test. The resulting simulated test data are analyzed via ANOVA and a parametric model is constructed using RSM. Finally, ANOVA can be used to plan a second round of testing to augment the existing data set with new data points. The use of these techniques is demonstrated through several illustrative examples. To date, many thousands of comparisons have been performed and the results strongly support the conclusion that the distributed testing approach outperforms the clustered testing approach.
ERIC Educational Resources Information Center
Luh, Wei-Ming; Guo, Jiin-Huarng
2005-01-01
To deal with nonnormal and heterogeneous data for the one-way fixed effect analysis of variance model, the authors adopted a trimmed means method in conjunction with Hall's invertible transformation into a heteroscedastic test statistic (Alexander-Govern test or Welch test). The results of simulation experiments showed that the proposed technique…
NASA Technical Reports Server (NTRS)
Brissenden, R. J. V.; Chartas, G.; Freeman, M. D.; Hughes, J. P.; Kellogg, E. M.; Podgorski, W. A.; Schwartz, D. A.; Zhao, P.
1992-01-01
This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report.
Multiple comparison analysis testing in ANOVA.
McHugh, Mary L
2011-01-01
The Analysis of Variance (ANOVA) test has long been an important tool for researchers conducting studies on multiple experimental groups and one or more control groups. However, ANOVA cannot provide detailed information on differences among the various study groups, or on complex combinations of study groups. To fully understand group differences in an ANOVA, researchers must conduct tests of the differences between particular pairs of experimental and control groups. Tests conducted on subsets of data tested previously in another analysis are called post hoc tests. A class of post hoc tests that provide this type of detailed information for ANOVA results are called "multiple comparison analysis" tests. The most commonly used multiple comparison analysis statistics include the following tests: Tukey, Newman-Keuls, Scheffee, Bonferroni and Dunnett. These statistical tools each have specific uses, advantages and disadvantages. Some are best used for testing theory while others are useful in generating new theory. Selection of the appropriate post hoc test will provide researchers with the most detailed information while limiting Type 1 errors due to alpha inflation.
Post irradiation analysis of RERTR-7A, 7B and RERTR-8 tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hofman, G.L.; Kim, Yeon Soo; Shevlyakov, G.V.
2008-07-15
Addition of 2 wt% or more of silicon in the Al matrix for U-Mo/Al dispersion fuel has proved to be effective in reducing interaction layer growth from the RERTR-7A test to a burnup of {approx}100 at% U-235 (LEU equivalent). The recent RERTR-8 test also showed the consistent results. In this paper, we present the post irradiation analysis results of these tests. A considerable number of monolithic fuel plates were irradiated in the RERTR-7A and RERTR-8 tests. The post irradiation results of these plates are also included. The RERTR-7B test was a lower burnup test with similar power to the RERTR-7A.more » In this test, dispersion fuel plates with U-7Mo-1Ti and U- 7Mo-2Zr in Al-5Si were irradiated. The post irradiation results of these plates are also covered. (author)« less
NASA Technical Reports Server (NTRS)
Mason, P. W.; Harris, H. G.; Zalesak, J.; Bernstein, M.
1974-01-01
The methods and procedures used in the analysis and testing of the scale model are reported together with the correlation of the analytical and experimental results. The model, the NASTRAN finite element analysis, and results are discussed. Tests and analytical investigations are also reported.
ERIC Educational Resources Information Center
Martens, Brian K.; Gertz, Lynne E.; Werder, Candace Susan de Lacy; Rymanowski, Jennifer L.
2010-01-01
We compared the results of a contingency space analysis (CSA) of behavior-consequence recordings to the results of functional analysis (FA) test conditions involving antecedent stimuli and verbal statements that both differed from and mimicked those in the natural environment. Three preschool children with autism spectrum disorder participated.…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-25
... definitive test that documents your disorder (for example, genetic analysis or evidence of biochemical... testing, and We will not accept the fluorescence in situ hybridization (FISH) test--a screening test--and... results even if the person did have a test. Because we do not have definitive test results, we would...
Herbicide Orange Site Characterization Study Naval Construction Battalion Center
1987-01-01
U.S. Testing Laboratories for analysis. Over 200 additional analyses were performed for a variety of quality assurance criteria. The resultant data...TABLE 9. NCBC PERFORMANCE AUDIT SAMPLE ANALYSIS SUNMARYa (SERIES 1) TCDD Sppb ) Reported Detection Relative b Sample Number Concentration Limit...limit rather than estimating the variance of the results. The sample results were transformed using the natural logarithm. The Shapiro-Wilk W test
NASA Technical Reports Server (NTRS)
Maasha, Rumaasha; Towner, Robert L.
2012-01-01
High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons
Shaikh, Masood Ali
2017-09-01
Assessment of research articles in terms of study designs used, statistical tests applied and the use of statistical analysis programmes help determine research activity profile and trends in the country. In this descriptive study, all original articles published by Journal of Pakistan Medical Association (JPMA) and Journal of the College of Physicians and Surgeons Pakistan (JCPSP), in the year 2015 were reviewed in terms of study designs used, application of statistical tests, and the use of statistical analysis programmes. JPMA and JCPSP published 192 and 128 original articles, respectively, in the year 2015. Results of this study indicate that cross-sectional study design, bivariate inferential statistical analysis entailing comparison between two variables/groups, and use of statistical software programme SPSS to be the most common study design, inferential statistical analysis, and statistical analysis software programmes, respectively. These results echo previously published assessment of these two journals for the year 2014.
Cost-effectiveness of point-of-care testing for dehydration in the pediatric ED.
Whitney, Rachel E; Santucci, Karen; Hsiao, Allen; Chen, Lei
2016-08-01
Acute gastroenteritis (AGE) and subsequent dehydration account for a large proportion of pediatric emergency department (PED) visits. Point-of-care (POC) testing has been used in conjunction with clinical assessment to determine the degree of dehydration. Despite the wide acceptance of POC testing, little formal cost-effective analysis of POC testing in the PED exists. We aim to examine the cost-effectiveness of using POC electrolyte testing vs traditional serum chemistry testing in the PED for children with AGE. This was a cost-effective analysis using data from a randomized control trial of children with AGE. A decision analysis model was constructed to calculate cost-savings from the point of view of the payer and the provider. We used parameters obtained from the trial, including cost of testing, admission rates, cost of admission, and length of stay. Sensitivity analyses were performed to evaluate the stability of our model. Using the data set of 225 subjects, POC testing results in a cost savings of $303.30 per patient compared with traditional serum testing from the point of the view of the payer. From the point-of-view of the provider, POC testing results in consistent mean savings of $36.32 ($8.29-$64.35) per patient. Sensitivity analyses demonstrated the stability of the model and consistent savings. This decision analysis provides evidence that POC testing in children with gastroenteritis-related moderate dehydration results in significant cost savings from the points of view of payers and providers compared to traditional serum chemistry testing. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Marchis, Iuliana
2009-01-01
The results of the Romanian pupils on international tests PISA and TIMSS in Mathematics are below the average. These poor results have many explications. In this article we compare the Mathematics problems given on these international tests with those given on national tests in Romania.
Cost-effectiveness of the Carbon-13 Urea Breath Test for the Detection of Helicobacter Pylori
Masucci, L; Blackhouse, G; Goeree, R
2013-01-01
Objectives This analysis aimed to evaluate the cost-effectiveness of various testing strategies for Helicobacter pylori in patients with uninvestigated dyspepsia and to calculate the budgetary impact of these tests for the province of Ontario. Data Sources Data on the sensitivity and specificity were obtained from the clinical evidence-based analysis. Resource items were obtained from expert opinion, and costs were applied on the basis of published sources as well as expert opinion. Review Methods A decision analytic model was constructed to compare the costs and outcomes (false-positive results, false-negative results, and misdiagnoses avoided) of the carbon-13 (13C) urea breath test (UBT), enzyme-linked immunosorbent assay (ELISA) serology test, and a 2-step strategy of an ELISA serology test and a confirmatory 13C UBT based on the sensitivity and specificity of the tests and prevalence estimates. Results The 2-step strategy is more costly and more effective than the ELISA serology test and results in $210 per misdiagnosis case avoided. The 13C UBT is dominated by the 2-step strategy, i.e., it is more costly and less effective. The budget impact analysis indicates that it will cost $7.9 million more to test a volume of 129,307 patients with the 13C UBT than with ELISA serology, and $4.7 million more to test these patients with the 2-step strategy. Limitations The clinical studies that were pooled varied in the technique used to perform the breath test and in reference standards used to make comparisons with the breath test. However, these parameters were varied in a sensitivity analysis. The economic model was designed to consider intermediate outcomes only (i.e., misdiagnosed cases) and was not a complete model with final patient outcomes (e.g., quality-adjusted life years). Conclusions Results indicate that the 2-step strategy could be economically attractive for the testing of H. pylori. However, testing with the 2-step strategy will cost the Ministry of Health and Long-Term Care $4.7 million more than with the ELISA serology test. PMID:24228083
Lee, Sung-Jae; Brooks, Ronald; Bolan, Robert K.; Flynn, Risa
2013-01-01
Men who have sex with men (MSM) in the United States represent a vulnerable population with lower rates of HIV testing. There are various specific attributes of HIV testing that may impact willingness to test (WTT) for HIV. Identifying specific attributes influencing patients’ decisions around WTT for HIV is critical to ensure improved HIV testing uptake. This study examined WTT for HIV by using conjoint analysis, an innovative method for systematically estimating consumer preferences across discrete attributes. WTT for HIV was assessed across eight hypothetical HIV testing scenarios varying across seven dichotomous attributes: location (home vs. clinic), price (free vs. $50), sample collection (finger prick vs. blood), timeliness of results (immediate vs. 1–2 weeks), privacy (anonymous vs. confidential), results given (by phone vs. in-person), and type of counseling (brochure vs. in-person). Seventy-five MSM were recruited from a community based organization providing HIV testing services in Los Angeles to participate in conjoint analysis. WTT for HIV score was based on a 100-point scale. Scores ranged from 32.2 to 80.3 for eight hypothetical HIV testing scenarios. Price of HIV testing (free vs. $50) had the highest impact on WTT (impact score=31.4, SD=29.2, p<.0001), followed by timeliness of results (immediate vs. 1–2 weeks) (impact score=13.9, SD=19.9, p=<.0001) and testing location (home vs. clinic) (impact score=10.3, SD=22.8, p=.0002). Impacts of other HIV testing attributes were not significant. Conjoint analysis method enabled direct assessment of HIV testing preferences and identified specific attributes that significantly impact WTT for HIV among MSM. This method provided empirical evidence to support the potential uptake of the newly FDA-approved over-the-counter HIV home-test kit with immediate results, with cautionary note on the cost of the kit. PMID:23651439
Comparison of analysis and flight test data for a drone aircraft with active flutter suppression
NASA Technical Reports Server (NTRS)
Newsom, J. R.; Pototzky, A. S.
1981-01-01
This paper presents a comparison of analysis and flight test data for a drone aircraft equipped with an active flutter suppression system. Emphasis is placed on the comparison of modal dampings and frequencies as a function of Mach number. Results are presented for both symmetric and antisymmetric motion with flutter suppression off. Only symmetric results are presented for flutter suppression on. Frequency response functions of the vehicle are presented from both flight test data and analysis. The analysis correlation is improved by using an empirical aerodynamic correction factor which is proportional to the ratio of experimental to analytical steady-state lift curve slope. In addition to presenting the mathematical models and a brief description of existing analytical techniques, an alternative analytical technique for obtaining closed-loop results is presented.
Development of allele-specific multiplex PCR to determine the length of poly-T in intron 8 of CFTR
Prada, Anne E.
2014-01-01
Cystic fibrosis transmembrane conductance regulator (CFTR) gene mutation analysis has been implemented for Cystic Fibrosis (CF) carrier screening, and molecular diagnosis of CF and congenital bilateral absence of the vas deferens (CBAVD). Although poly-T allele analysis in intron 8 of CFTR is required when a patient is positive for R117H, it is not recommended for routine carrier screening. Therefore, commercial kits for CFTR mutation analysis were designed either to mask the poly-T allele results, unless a patient is R117H positive, or to have the poly-T analysis as a standalone reflex test using the same commercial platform. There are other standalone assays developed to detect poly-T alleles, such as heteroduplex analysis, High Resolution Melting (HRM) curve analysis, allele-specific PCR (AS-PCR) and Sanger sequencing. In this report, we developed a simple and easy-to-implement multiplex AS-PCR assay using unlabeled standard length primers, which can be used as a reflex or standalone test for CFTR poly-T track analysis. Out of 115 human gDNA samples tested, results from our new AS-PCR matched to the previous known poly-T results or results from Sanger sequencing. PMID:25071991
ERIC Educational Resources Information Center
Bailey, Kathleen M., Ed.; And Others
This collection of 10 selected conference papers report the results of language testing research. Titles and authors are: "Computerized Adaptive Language Testing: A Spanish Placement Exam" (Jerry W. Larson); "Utilizing Rasch Analysis to Detect Cheating on Language Examinations" (Harold S. Madsen); "Scalar Analysis of…
Classroom-Based Strategies to Incorporate Hypothesis Testing in Functional Behavior Assessments
ERIC Educational Resources Information Center
Lloyd, Blair P.; Weaver, Emily S.; Staubitz, Johanna L.
2017-01-01
When results of descriptive functional behavior assessments are unclear, hypothesis testing can help school teams understand how the classroom environment affects a student's challenging behavior. This article describes two hypothesis testing strategies that can be used in classroom settings: structural analysis and functional analysis. For each…
Flight-testing and frequency-domain analysis for rotorcraft handling qualities
NASA Technical Reports Server (NTRS)
Ham, Johnnie A.; Gardner, Charles K.; Tischler, Mark B.
1995-01-01
A demonstration of frequency-domain flight-testing techniques and analysis was performed on a U.S. Army OH-58D helicopter in support of the OH-58D Airworthiness and Flight Characteristics Evaluation and of the Army's development and ongoing review of Aeronautical Design Standard 33C, Handling Qualities Requirements for Military Rotorcraft. Hover and forward flight (60 kn) tests were conducted in 1 flight hour by Army experimental test pilots. Further processing of the hover data generated a complete database of velocity, angular-rate, and acceleration-frequency responses to control inputs. A joint effort was then undertaken by the Airworthiness Qualification Test Dirtectorate and the U.S. Army Aeroflightdynamics Directorate to derive handling-quality information from the frequency-domain database using a variety of approaches. This report documents numerous results that have been obtained from the simple frequency-domain tests; in many areas, these results provide more insight into the aircraft dynmamics that affect handling qualities than do traditional flight tests. The handling-quality results include ADS-33C bandwidth and phase-delay calculations, vibration spectral determinations, transfer-function models to examine single-axis results, and a six-degree-of-freedom fully coupled state-space model. The ability of this model to accurately predict responses was verified using data from pulse inputs. This report also documents the frequency-sweep flight-test technique and data analysis used to support the tests.
Water impact analysis of space shuttle solid rocket motor by the finite element method
NASA Technical Reports Server (NTRS)
Buyukozturk, O.; Hibbitt, H. D.; Sorensen, E. P.
1974-01-01
Preliminary analysis showed that the doubly curved triangular shell elements were too stiff for these shell structures. The doubly curved quadrilateral shell elements were found to give much improved results. A total of six load cases were analyzed in this study. The load cases were either those resulting from a static test using reaction straps to simulate the drop conditions or under assumed hydrodynamic conditions resulting from a drop test. The latter hydrodynamic conditions were obtained through an emperical fit of available data. Results obtained from a linear analysis were found to be consistent with results obtained elsewhere with NASTRAN and BOSOR. The nonlinear analysis showed that the originally assumed loads would result in failure of the shell structures. The nonlinear analysis also showed that it was useful to apply internal pressure as a stabilizing influence on collapse. A final analysis with an updated estimate of load conditions resulted in linear behavior up to full load.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labby, Z.
Physicists are often expected to have a solid grounding in experimental design and statistical analysis, sometimes filling in when biostatisticians or other experts are not available for consultation. Unfortunately, graduate education on these topics is seldom emphasized and few opportunities for continuing education exist. Clinical physicists incorporate new technology and methods into their practice based on published literature. A poor understanding of experimental design and analysis could Result in inappropriate use of new techniques. Clinical physicists also improve current practice through quality initiatives that require sound experimental design and analysis. Academic physicists with a poor understanding of design and analysismore » may produce ambiguous (or misleading) results. This can Result in unnecessary rewrites, publication rejection, and experimental redesign (wasting time, money, and effort). This symposium will provide a practical review of error and uncertainty, common study designs, and statistical tests. Instruction will primarily focus on practical implementation through examples and answer questions such as: where would you typically apply the test/design and where is the test/design typically misapplied (i.e., common pitfalls)? An analysis of error and uncertainty will also be explored using biological studies and associated modeling as a specific use case. Learning Objectives: Understand common experimental testing and clinical trial designs, what questions they can answer, and how to interpret the results Determine where specific statistical tests are appropriate and identify common pitfalls Understand the how uncertainty and error are addressed in biological testing and associated biological modeling.« less
Results from the 2014 drug and alcohol testing survey : analysis brief.
DOT National Transportation Integrated Search
2016-10-01
This report summarizes the results of the 2014 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...
Results from the 2016 Drug and Alcohol Testing Survey : Analysis Brief
DOT National Transportation Integrated Search
2018-01-01
This report summarizes the results of the 2016 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...
Drug and alcohol testing results 1996 annual report
DOT National Transportation Integrated Search
1997-12-01
The report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1996. The report covers testing results for the following drug types: marijuana (THC), cocaine, phencyclidine (P...
Results from the 2012 drug and alcohol testing survey : [analysis brief].
DOT National Transportation Integrated Search
2014-12-01
This report summarizes the results of the 2012 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) who test positive for...
Results from the 2015 Drug and Alcohol Testing Survey : analysis brief.
DOT National Transportation Integrated Search
2017-06-01
This report summarizes the results of the 2015 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...
ERIC Educational Resources Information Center
Osler, James Edward
2014-01-01
This monograph provides an epistemological rational for the design of a novel post hoc statistical measure called "Tri-Center Analysis". This new statistic is designed to analyze the post hoc outcomes of the Tri-Squared Test. In Tri-Center Analysis trichotomous parametric inferential parametric statistical measures are calculated from…
Finite Elements Analysis of a Composite Semi-Span Test Article With and Without Discrete Damage
NASA Technical Reports Server (NTRS)
Lovejoy, Andrew E.; Jegley, Dawn C. (Technical Monitor)
2000-01-01
AS&M Inc. performed finite element analysis, with and without discrete damage, of a composite semi-span test article that represents the Boeing 220-passenger transport aircraft composite semi-span test article. A NASTRAN bulk data file and drawings of the test mount fixtures and semi-span components were utilized to generate the baseline finite element model. In this model, the stringer blades are represented by shell elements, and the stringer flanges are combined with the skin. Numerous modeling modifications and discrete source damage scenarios were applied to the test article model throughout the course of the study. This report details the analysis method and results obtained from the composite semi-span study. Analyses were carried out for three load cases: Braked Roll, LOG Down-Bending and 2.5G Up-Bending. These analyses included linear and nonlinear static response, as well as linear and nonlinear buckling response. Results are presented in the form of stress and strain plots. factors of safety for failed elements, buckling loads and modes, deflection prediction tables and plots, and strainage prediction tables and plots. The collected results are presented within this report for comparison to test results.
Novel Image Encryption Scheme Based on Chebyshev Polynomial and Duffing Map
2014-01-01
We present a novel image encryption algorithm using Chebyshev polynomial based on permutation and substitution and Duffing map based on substitution. Comprehensive security analysis has been performed on the designed scheme using key space analysis, visual testing, histogram analysis, information entropy calculation, correlation coefficient analysis, differential analysis, key sensitivity test, and speed test. The study demonstrates that the proposed image encryption algorithm shows advantages of more than 10113 key space and desirable level of security based on the good statistical results and theoretical arguments. PMID:25143970
Predictability of Brayton electric power system performance
NASA Technical Reports Server (NTRS)
Klann, J. L.; Hettel, H. J.
1972-01-01
Data from the first tests of the 2- to 15-kilowatt space power system in a vacuum chamber were compared with predictions of both a pretest analysis and a modified version of that analysis. The pretest analysis predicted test results with differences of no more than 9 percent of the largest measured value for each quantity. The modified analysis correlated measurements. Differences in conversion efficiency and power output were no greater than plus or minus 2.5 percent. This modified analysis was used to project space performance maps for the current test system.
Junkuy, Anongphan; Aramrattana, Apinun; Sribanditmongkol, Pongruk
2014-07-01
Three diagnostic methods have dominated drug-abuse research: self-report, urinalysis and hair analysis. Previous studies have compared detection rates for various drugs, but none has focused a three-pronged concordance study on the use of methamphetamine (MA). To determine and compare the rates of MA detection in urine and hair of subjects who reported consuming MA in the form of Yaba. Self-reports of Yaba use, as well as biological specimens for chemical analyses, were collected from paid volunteers participating in a larger project studying risk-taking behavior of young adults in northern Thailand. All subjects in the present study reported using Yaba within 90 days of enrollment. Hair analysis for MA followed a validated protocol that coupled solid phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS). Preliminary urinalysis was by means of REMEDi-HS. Positive urine was confirmed for MA by the SPME/GC-MS protocol. The MA detection rate by hair analysis (34.3%, n = 172) was significantly higher than by urinalysis (19.1%, n = 96) (p < 0.01; McNemar's test). All subjects with MA-positive urine samples reported using Yaba within 30 days of testing, while hair analysis gave positive results for self-reports up to 90 days. Urinalysis showed greater concordance with self-report than hair analysis if testing occurred within seven days of most recent admitted Yaba use. The reverse was true after 14 days. Agreement of laboratory findings with self-reports increased if test results for the two biological matrices were combined. There was no strong agreement between hair analysis and urinalysis for subjects reporting most recent use within 30 days of testing (kappa = 0.131; 95% CI = 0.022-0.240). For the Yaba users in the present study, urinalysis for MA significantly detected more positives than hair analysis if the most recent use reportedly occurred within seven days of testing. Hair analysis yielded better results after an interval of 14 days, with its window of detection extending up to three months. There were no urine positive samples for reported use after 30 days. Combining urinalysis and hair analysis increased the probability of detecting recent MA use. Both urinalysis and hair analysis significantly under-detected MA in the biological samples collected. The combined detection rate was 44.4%. This discrepancy might have resulted from over-reporting of Yaba use due to social/psychological factors and/or insufficient MA consumption causing test results to fall below cutoff levels.
Hayashimoto, Nobuhito; Ueno, Masami; Tkakura, Akira; Itoh, Toshio
2007-06-01
Phylogenetic analysis based on 16S rRNA sequences with sequence data of some bacterial species of Pasteurellaceae related to rodents deposited in GenBank was performed along with biochemical characterization for the 20 strains of V-factor dependent members of Pasteurellaceae derived from laboratory rats to obtain basic information and to investigate the taxonomic positions. The results of biochemical tests for all strains were identical except for three tests, the ornithine decarboxylase test, and fermentation tests of D(+) mannose and D(+) xylose. The biochemical properties of 8 of 20 strains that showed negative results for the fermentation test of D(+) xylose agreed with those of Haemophilus parainfluenzae complex. By phylogenetic analysis, the strains were divided into two clusters that agreed with the results of the fermentation test of xylose (group I: negative reaction for xylose, group II: positive reaction for xylose). The clusters were independent of other bacterial species of Pasteurellaceae tested. The sequences of the strains in group I showed 99.7-99.8% similarity and the strains in group II showed 99.3-99.7% similarity. None of the strains in group I had a close relation with Haemophilus parainfluenzae by phylogenetic analysis, although they showed the same biochemical properties. In conclusion, the strains had characteristic biochemical properties and formed two independent groups within the "rodent cluster" of Pasteurellaceae that differed in the results of the fermentation test of xylose. Therefore, they seemed to be hitherto undescribed taxa in Pasteurellaceae.
Optimization of structures on the basis of fracture mechanics and reliability criteria
NASA Technical Reports Server (NTRS)
Heer, E.; Yang, J. N.
1973-01-01
Systematic summary of factors which are involved in optimization of given structural configuration is part of report resulting from study of analysis of objective function. Predicted reliability of performance of finished structure is sharply dependent upon results of coupon tests. Optimization analysis developed by study also involves expected cost of proof testing.
RERTR-13 Irradiation Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. M. Perez; M. A. Lillo; G. S. Chang
2012-09-01
The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-13 was designed to assess performance of different types of neutron absorbers that can be potentially used as burnable poisons in the low enriched uranium-molybdenum based dispersion and monolithic fuels.1 The following report summarizes the life of the RERTR-13 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.
Making the Hubble Space Telescope servicing mission safe
NASA Technical Reports Server (NTRS)
Bahr, N. J.; Depalo, S. V.
1992-01-01
The implementation of the HST system safety program is detailed. Numerous safety analyses are conducted through various phases of design, test, and fabrication, and results are presented to NASA management for discussion during dedicated safety reviews. Attention is given to the system safety assessment and risk analysis methodologies used, i.e., hazard analysis, fault tree analysis, and failure modes and effects analysis, and to how they are coupled with engineering and test analysis for a 'synergistic picture' of the system. Some preliminary safety analysis results, showing the relationship between hazard identification, control or abatement, and finally control verification, are presented as examples of this safety process.
Land utilization and water resource inventories over extended test sites
NASA Technical Reports Server (NTRS)
Hoffer, R. M.
1972-01-01
In addition to the work on the corn blight this year, several other analysis tests were completed which resulted in significant findings. These aspects are discussed as follows: (1) field spectral measurements of soil conditions; (2) analysis of extended test site data; this discussion involves three different sets of data analysis sequences; (3) urban land use analysis, for studying water runoff potentials; and (4) thermal data quality study, as an expansion of our water resources studies involving temperature calibration techniques.
NASA Technical Reports Server (NTRS)
Soulas, George C.
2013-01-01
A study was conducted to quantify the impact of back-sputtered carbon on the downstream accelerator grid erosion rates of the NASA's Evolutionary Xenon Thruster (NEXT) Long Duration Test (LDT1). A similar analysis that was conducted for the NASA's Solar Electric Propulsion Technology Applications Readiness Program (NSTAR) Life Demonstration Test (LDT2) was used as a foundation for the analysis developed herein. A new carbon surface coverage model was developed that accounted for multiple carbon adlayers before complete surface coverage is achieved. The resulting model requires knowledge of more model inputs, so they were conservatively estimated using the results of past thin film sputtering studies and particle reflection predictions. In addition, accelerator current densities across the grid were rigorously determined using an ion optics code to determine accelerator current distributions and an algorithm to determine beam current densities along a grid using downstream measurements. The improved analysis was applied to the NSTAR test results for evaluation. The improved analysis demonstrated that the impact of back-sputtered carbon on pit and groove wear rate for the NSTAR LDT2 was negligible throughout most of eroded grid radius. The improved analysis also predicted the accelerator current density for transition from net erosion to net deposition considerably more accurately than the original analysis. The improved analysis was used to estimate the impact of back-sputtered carbon on the accelerator grid pit and groove wear rate of the NEXT Long Duration Test (LDT1). Unlike the NSTAR analysis, the NEXT analysis was more challenging because the thruster was operated for extended durations at various operating conditions and was unavailable for measurements because the test is ongoing. As a result, the NEXT LDT1 estimates presented herein are considered preliminary until the results of future post-test analyses are incorporated. The worst-case impact of carbon back-sputtering was determined to be the full power operating condition, but the maximum impact of back-sputtered carbon was only a 4 percent reduction in wear rate. As a result, back-sputtered carbon is estimated to have an insignificant impact on the first failure mode of the NEXT LDT1 at all operating conditions.
Space simulation facilities providing a stable thermal vacuum facility
NASA Technical Reports Server (NTRS)
Tellalian, Martin L.
1990-01-01
CBI has recently constructed the Intermediate Thermal Vacuum Facility. Built as a corporate facility, the installation will first be used on the Boost Surveillance and Tracking System (BSTS) program. It will also be used to develop and test other sensor systems. The horizontal chamber has a horseshoe shaped cross section and is supported on pneumatic isolators for vibration isolation. The chamber structure was designed to meet stability and stiffness requirements. The design process included measurement of the ambient ground vibrations, analysis of various foundation test article support configurations, design and analysis of the chamber shell and modal testing of the chamber shell. A detailed 3-D finite element analysis was made in the design stage to predict the lowest three natural frequencies and mode shapes and to identify local vibrating components. The design process is described and the results are compared of the finite element analysis to the results of the field modal testing and analysis for the 3 lowest natural frequencies and mode shapes. Concepts are also presented for stiffening large steel structures along with methods to improve test article stability in large space simulation facilities.
Romanyukha, Alex; Schauer, David A; Malikov, Yurii K
2006-02-01
Between 1949 and 1989 the Semipalatinsk nuclear test site (SNTS), an area of 19,000 square km in northeastern Kazakhstan, was the location of over 400 nuclear test explosions with a total explosive energy of 6.6 Mt TNT (trinitrotoluene or trotyl) equivalent. It is estimated that the bulk of the radiation exposure to the population resulted from three tests, conducted in 1949, 1951, and 1953 although estimations of radiation doses received by the local population have varied significantly. Analysis of the published ESR dose reconstruction results for residents of the villages near the SNTS show that they do not correlate well with other methods of dose assessment (e.g. model dose calculation and thermo luminescence dosimetry (TLD) in bricks). The most significant difference in dose estimations was found for the population of Dolon, which was exposed as result of the first Soviet nuclear test in 1949. Published results of ESR measurements in tooth enamel are considerably lower than other dose estimations. Detailed analysis of these results is provided and a possible explanation for this discrepancy and ways to eliminate it are suggested.
Test report for single event effects of the 80386DX microprocessor
NASA Technical Reports Server (NTRS)
Watson, R. Kevin; Schwartz, Harvey R.; Nichols, Donald K.
1993-01-01
The Jet Propulsion Laboratory Section 514 Single Event Effects (SEE) Testing and Analysis Group has performed a series of SEE tests of certain strategic registers of Intel's 80386DX CHMOS 4 microprocessor. Following a summary of the test techniques and hardware used to gather the data, we present the SEE heavy ion and proton test results. We also describe the registers tested, along with a system impact analysis should these registers experience a single event upset.
Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Daniel, Jennifer C., E-mail: jennifer.odaniel@duke.edu; Yin, Fang-Fang
Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vsmore » treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.« less
Galileo environmental test and analysis program summary
NASA Technical Reports Server (NTRS)
Hoffman, A. R.
1991-01-01
This paper presents an overview of the Galileo Project's environmental test and analysis program during the spacecraft development phase - October 1978 through launch in October 1989. After describing the top-level objectives of the program, summaries of-the approach, requirements, and margins are provided. Examples of assembly- and system-level test results are given for both the pre-1986 (direct mission) testing and the post-1986 (Venus-Earth-Earth gravity assist mission) testing, including dynamic, thermal, electromagnetic compatibility (EMC), and magnetic. The approaches and results for verifying by analysis that the requirements of certain environments (e.g., radiation, micrometeoroids, and single event upsets) are satisfied are presented. The environmental program implemented on Galileo satisfied the spirit and intent of the requirements imposed by the Project during the spacecraft's development. The lessons learned from the Galileo environmental program are discussed in this paper.
Double Aneuploidy Detected by Cell-Free DNA Testing and Confirmed by Fetal Tissue Analysis.
Echague, Charlene G; Petersen, Scott M
2016-06-01
Double aneuploidies account for 0.21-2.8% of spontaneous abortions resulting from chromosomal abnormalities. Rarely, cell-free DNA testing detects multiple aneuploidies; however, to discern among maternal, placental, and fetal origin, further evaluation is required. A 49-year-old woman, gravida 5 para 0, underwent cell-free DNA testing at 11 4/7 weeks of gestation, which revealed a fetus that was high risk for trisomies 18 and 21. On ultrasonography at 14 weeks of gestation, she was diagnosed with a missed abortion and underwent surgical management. Fetal and placental tissues were sent for analysis and were positive for trisomies 18 and 21, confirming the results of cell-free DNA testing. Our case highlights the ability of cell-free DNA testing to recognize a double aneuploidy confirmed by fetal tissue analysis.
NASA Technical Reports Server (NTRS)
Scudder, Nathan F
1934-01-01
This report presents the results of an investigation of the spinning characteristics of NY-1 naval training biplane. The results of flight tests and an analysis based on wind-tunnel test data are given and compared. The primary purpose of the investigation was the determination in flight of the effect of changes in mass distribution along the longitudinal axis, without change of mass quantity or centroid. Other effects were also investigated, such as those due to wing loading, center-of-gravity position, dihedral of wings, control setting, and the removal of a large portion of the fabric from the fin and rudder. The wind tunnel test results used in the numerical analysis were obtained in the 7 by 10 foot wind tunnel through an angle-of-attack.
ERIC Educational Resources Information Center
Sung, Youl-Kwan; Kang, Mi Ok
2012-01-01
This paper examines the ideological construction of educational discourses embedded within the South Korean print media. Significantly, these discourses have recently promoted the resurrection of a sweeping national testing and test results release policy. Through careful examination of the "test plus release" policy, the authors show…
NASA Technical Reports Server (NTRS)
Soulas, George C.
2013-01-01
A study was conducted to quantify the impact of back-sputtered carbon on the downstream accelerator grid erosion rates of the NEXT (NASA's Evolutionary Xenon Thruster) Long Duration Test (LDT1). A similar analysis that was conducted for the NSTAR (NASA's Solar Electric Propulsion Technology Applications Readiness Program) Life Demonstration Test (LDT2) was used as a foundation for the analysis developed herein. A new carbon surface coverage model was developed that accounted for multiple carbon adlayers before complete surface coverage is achieved. The resulting model requires knowledge of more model inputs, so they were conservatively estimated using the results of past thin film sputtering studies and particle reflection predictions. In addition, accelerator current densities across the grid were rigorously determined using an ion optics code to determine accelerator current distributions and an algorithm to determine beam current densities along a grid using downstream measurements. The improved analysis was applied to the NSTAR test results for evaluation. The improved analysis demonstrated that the impact of back-sputtered carbon on pit and groove wear rate for the NSTAR LDT2 was negligible throughout most of eroded grid radius. The improved analysis also predicted the accelerator current density for transition from net erosion to net deposition considerably more accurately than the original analysis. The improved analysis was used to estimate the impact of back-sputtered carbon on the accelerator grid pit and groove wear rate of the NEXT Long Duration Test (LDT1). Unlike the NSTAR analysis, the NEXT analysis was more challenging because the thruster was operated for extended durations at various operating conditions and was unavailable for measurements because the test is ongoing. As a result, the NEXT LDT1 estimates presented herein are considered preliminary until the results of future posttest analyses are incorporated. The worst-case impact of carbon back-sputtering was determined to be the full power operating condition, but the maximum impact of back-sputtered carbon was only a four percent reduction in wear rate. As a result, back-sputtered carbon is estimated to have an insignificant impact on the first failure mode of the NEXT LDT at all operating conditions.
DEIVA: a web application for interactive visual analysis of differential gene expression profiles.
Harshbarger, Jayson; Kratz, Anton; Carninci, Piero
2017-01-07
Differential gene expression (DGE) analysis is a technique to identify statistically significant differences in RNA abundance for genes or arbitrary features between different biological states. The result of a DGE test is typically further analyzed using statistical software, spreadsheets or custom ad hoc algorithms. We identified a need for a web-based system to share DGE statistical test results, and locate and identify genes in DGE statistical test results with a very low barrier of entry. We have developed DEIVA, a free and open source, browser-based single page application (SPA) with a strong emphasis on being user friendly that enables locating and identifying single or multiple genes in an immediate, interactive, and intuitive manner. By design, DEIVA scales with very large numbers of users and datasets. Compared to existing software, DEIVA offers a unique combination of design decisions that enable inspection and analysis of DGE statistical test results with an emphasis on ease of use.
Test Results of Initial Installation DATAS/TCAS Monitor: DFW Airport
DOT National Transportation Integrated Search
1992-01-01
This document presents the results of initial tests with the Data Link Test and : Analysis System (DATAS)/Traffic Alert and Collision Avoidance System (TCAS). : Since a significant amount of air carriers have recently been equipped with : Traffic Ale...
NASTRAN applications to aircraft propulsion systems
NASA Technical Reports Server (NTRS)
White, J. L.; Beste, D. L.
1975-01-01
The use of NASTRAN in propulsion system structural integration analysis is described. Computer support programs for modeling, substructuring, and plotting analysis results are discussed. Requirements on interface information and data exchange by participants in a NASTRAN substructure analysis are given. Static and normal modes vibration analysis results are given with comparison to test and other analytical results.
AGR-1 Thermocouple Data Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeff Einerson
2012-05-01
This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods tomore » further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of simulation results (Chapter 3). The statistics-based simulation-aided experimental control procedure described for the future AGR tests is developed and demonstrated in Chapter 4. The procedure for controlling the target fuel temperature (capsule peak or average) is based on regression functions of thermocouple readings and other relevant parameters and accounting for possible changes in both physical and thermal conditions and in instrument performance.« less
NASA Technical Reports Server (NTRS)
Macwilkinson, D. G.; Blackerby, W. T.; Paterson, J. H.
1974-01-01
The degree of cruise drag correlation on the C-141A aircraft is determined between predictions based on wind tunnel test data, and flight test results. An analysis of wind tunnel tests on a 0.0275 scale model at Reynolds number up to 3.05 x 1 million/MAC is reported. Model support interference corrections are evaluated through a series of tests, and fully corrected model data are analyzed to provide details on model component interference factors. It is shown that predicted minimum profile drag for the complete configuration agrees within 0.75% of flight test data, using a wind tunnel extrapolation method based on flat plate skin friction and component shape factors. An alternative method of extrapolation, based on computed profile drag from a subsonic viscous theory, results in a prediction four percent lower than flight test data.
Blade loss transient dynamic analysis of turbomachinery
NASA Technical Reports Server (NTRS)
Stallone, M. J.; Gallardo, V.; Storace, A. F.; Bach, L. J.; Black, G.; Gaffney, E. F.
1982-01-01
This paper reports on work completed to develop an analytical method for predicting the transient non-linear response of a complete aircraft engine system due to the loss of a fan blade, and to validate the analysis by comparing the results against actual blade loss test data. The solution, which is based on the component element method, accounts for rotor-to-casing rubs, high damping and rapid deceleration rates associated with the blade loss event. A comparison of test results and predicted response show good agreement except for an initial overshoot spike not observed in test. The method is effective for analysis of large systems.
Muon catalyzed fusion beam window mechanical strength testing and analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ware, A.G.; Zabriskie, J.M.
A thin aluminum window (0.127 mm (0.005-inch) thick x 146 mm (5 3/4-inch) diameter) of 2024-T6 alloy was modeled and analyzed using the ABAQUS non-linear finite element analysis code. A group of windows was fabricated, heat-treated and subsequently tested. Testing included both ultimate burst pressure and fatigue. Fatigue testing cycles involved ''oil-canning'' behavior representing vacuum purge and reversal to pressure. Test results are compared to predictions and the mode of failure is discussed. Operational requirements, based on the above analysis and correlational testing, for the actual beam windows are discussed. 1 ref., 3 figs.
Kondo, M; Nagao, Y; Mahbub, M H; Tanabe, T; Tanizawa, Y
2018-04-29
To identify factors predicting early postpartum glucose intolerance in Japanese women with gestational diabetes mellitus, using decision-curve analysis. A retrospective cohort study was performed. The participants were 123 Japanese women with gestational diabetes who underwent 75-g oral glucose tolerance tests at 8-12 weeks after delivery. They were divided into a glucose intolerance and a normal glucose tolerance group based on postpartum oral glucose tolerance test results. Analysis of the pregnancy oral glucose tolerance test results showed predictive factors for postpartum glucose intolerance. We also evaluated the clinical usefulness of the prediction model based on decision-curve analysis. Of 123 women, 78 (63.4%) had normoglycaemia and 45 (36.6%) had glucose intolerance. Multivariable logistic regression analysis showed insulinogenic index/fasting immunoreactive insulin and summation of glucose levels, assessed during pregnancy oral glucose tolerance tests (total glucose), to be independent risk factors for postpartum glucose intolerance. Evaluating the regression models, the best discrimination (area under the curve 0.725) was obtained using the basic model (i.e. age, family history of diabetes, BMI ≥25 kg/m 2 and use of insulin during pregnancy) plus insulinogenic index/fasting immunoreactive insulin <1.1. Decision-curve analysis showed that combining insulinogenic index/fasting immunoreactive insulin <1.1 with basic clinical information resulted in superior net benefits for prediction of postpartum glucose intolerance. Insulinogenic index/fasting immunoreactive insulin calculated using oral glucose tolerance test results during pregnancy is potentially useful for predicting early postpartum glucose intolerance in Japanese women with gestational diabetes. © 2018 Diabetes UK.
A method for developing design diagrams for ceramic and glass materials using fatigue data
NASA Technical Reports Server (NTRS)
Heslin, T. M.; Magida, M. B.; Forrest, K. A.
1986-01-01
The service lifetime of glass and ceramic materials can be expressed as a plot of time-to-failure versus applied stress whose plot is parametric in percent probability of failure. This type of plot is called a design diagram. Confidence interval estimates for such plots depend on the type of test that is used to generate the data, on assumptions made concerning the statistical distribution of the test results, and on the type of analysis used. This report outlines the development of design diagrams for glass and ceramic materials in engineering terms using static or dynamic fatigue tests, assuming either no particular statistical distribution of test results or a Weibull distribution and using either median value or homologous ratio analysis of the test results.
NASA Technical Reports Server (NTRS)
Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P
2017-01-01
Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.
ERIC Educational Resources Information Center
Umesh, U. N.; Mishra, Sanjay
1990-01-01
Major issues related to index-of-fit conjoint analysis were addressed in this simulation study. Goals were to develop goodness-of-fit criteria for conjoint analysis; develop tests to determine the significance of conjoint analysis results; and calculate the power of the test of the null hypothesis of random data distribution. (SLD)
Radon Assessment of Occupational Facilities, Grissom ARB, IN
2012-11-28
4) EPA 402-R-92-014, Radon Measurements in Schools , July 1993 b. Measurement Device Protocols: The following protocols were used when placing...Performance Tests : A biennial performance test from commercial vendors evaluates the proficiency of USAFSAM’s radon analysis. A proficiency test ...listing of duplicates and analysis. (4) Calibration Tests : Please see Attachment 4 for calibration certificates. 3. RESULTS: In total, 106 radon monitors
Markby, Jessica; Boeke, Caroline; Penazzato, Martina; Urick, Brittany; Ghadrshenas, Anisa; Harris, Lindsay; Ford, Nathan; Peter, Trevor
2017-01-01
Background: Despite significant gains made toward improving access, early infant diagnosis (EID) testing programs suffer from long test turnaround times that result in substantial loss to follow-up and mortality associated with delays in antiretroviral therapy initiation. These delays in treatment initiation are particularly impactful because of significant HIV-related infant mortality observed by 2–3 months of age. Short message service (SMS) and general packet radio service (GPRS) printers allow test results to be transmitted immediately to health care facilities on completion of testing in the laboratory. Methods: We conducted a systematic review and meta-analysis to assess the benefit of using SMS/GPRS printers to increase the efficiency of EID test result delivery compared with traditional courier paper–based results delivery methods. Results: We identified 11 studies contributing data for over 16,000 patients from East and Southern Africa. The test turnaround time from specimen collection to result received at the health care facility with courier paper–based methods was 68.0 days (n = 6835), whereas the test turnaround time with SMS/GPRS printers was 51.1 days (n = 6711), resulting in a 2.5-week (25%) reduction in the turnaround time. Conclusions: Courier paper–based EID test result delivery methods are estimated to add 2.5 weeks to EID test turnaround times in low resource settings and increase the risk that infants receive test results during or after the early peak of infant mortality. SMS/GPRS result delivery to health care facility printers significantly reduced test turnaround time and may reduce this risk. SMS/GPRS printers should be considered for expedited delivery of EID and other centralized laboratory test results. PMID:28825941
Development and Flight Testing of an Adaptable Vehicle Health-Monitoring Architecture
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.; Taylor, B. Douglas; Brett, Rube R.
2003-01-01
Development and testing of an adaptable wireless health-monitoring architecture for a vehicle fleet is presented. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained adaptable expert system. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate, and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear.
Suggestions for presenting the results of data analyses
Anderson, David R.; Link, William A.; Johnson, Douglas H.; Burnham, Kenneth P.
2001-01-01
We give suggestions for the presentation of research results from frequentist, information-theoretic, and Bayesian analysis paradigms, followed by several general suggestions. The information-theoretic and Bayesian methods offer alternative approaches to data analysis and inference compared to traditionally used methods. Guidance is lacking on the presentation of results under these alternative procedures and on nontesting aspects of classical frequentists methods of statistical analysis. Null hypothesis testing has come under intense criticism. We recommend less reporting of the results of statistical tests of null hypotheses in cases where the null is surely false anyway, or where the null hypothesis is of little interest to science or management.
Consequences of common data analysis inaccuracies in CNS trauma injury basic research.
Burke, Darlene A; Whittemore, Scott R; Magnuson, David S K
2013-05-15
The development of successful treatments for humans after traumatic brain or spinal cord injuries (TBI and SCI, respectively) requires animal research. This effort can be hampered when promising experimental results cannot be replicated because of incorrect data analysis procedures. To identify and hopefully avoid these errors in future studies, the articles in seven journals with the highest number of basic science central nervous system TBI and SCI animal research studies published in 2010 (N=125 articles) were reviewed for their data analysis procedures. After identifying the most common statistical errors, the implications of those findings were demonstrated by reanalyzing previously published data from our laboratories using the identified inappropriate statistical procedures, then comparing the two sets of results. Overall, 70% of the articles contained at least one type of inappropriate statistical procedure. The highest percentage involved incorrect post hoc t-tests (56.4%), followed by inappropriate parametric statistics (analysis of variance and t-test; 37.6%). Repeated Measures analysis was inappropriately missing in 52.0% of all articles and, among those with behavioral assessments, 58% were analyzed incorrectly. Reanalysis of our published data using the most common inappropriate statistical procedures resulted in a 14.1% average increase in significant effects compared to the original results. Specifically, an increase of 15.5% occurred with Independent t-tests and 11.1% after incorrect post hoc t-tests. Utilizing proper statistical procedures can allow more-definitive conclusions, facilitate replicability of research results, and enable more accurate translation of those results to the clinic.
Hamilton, Jada G; Lobel, Marci; Moyer, Anne
2009-07-01
Meta-analysis was used to synthesize results of studies on emotional consequences of predictive genetic testing for BRCA1/2 mutations conferring increased risk of breast and ovarian cancer. Studies assessing anxiety or cancer-specific distress before and after provision of test results (k = 20) were analyzed using a random-effects model. Moderator variables included country of data collection and personal cancer history of study participants. Standardized mean gain effect sizes were calculated for mutation carriers, noncarriers, and those with inconclusive results over short (0-4 weeks), moderate (5-24 weeks), or long (25-52 weeks) periods of time after testing. Distress among carriers increased shortly after receiving results and returned to pretesting levels over time. Distress among noncarriers and those with inconclusive results decreased over time. Some distress patterns differed in studies conducted outside the United States and for individuals with varying cancer histories. Results underscore the importance of time; changes in distress observed shortly after test-result disclosure frequently differed from the pattern of distress seen subsequently. Although emotional consequences of this testing appear minimal, it remains possible that testing may affect cognitive and behavioral outcomes, which have rarely been examined through meta-analysis. Testing may also affect understudied subgroups differently.
Burmeister, T; Maurer, J; Aivado, M; Elmaagacli, A H; Grünebach, F; Held, K R; Hess, G; Hochhaus, A; Höppner, W; Lentes, K U; Lübbert, M; Schäfer, K L; Schafhausen, P; Schmidt, C A; Schüler, F; Seeger, K; Seelig, R; Thiede, C; Viehmann, S; Weber, C; Wilhelm, S; Christmann, A; Clement, J H; Ebener, U; Enczmann, J; Leo, R; Schleuning, M; Schoch, R; Thiel, E
2000-10-01
Here we describe the results of an interlaboratory test for RT-PCR-based BCR/ABL analysis. The test was organized in two parts. The number of participating laboratories in the first and second part was 27 and 20, respectively. In the first part samples containing various concentrations of plasmids with the ela2, b2a2 or b3a2 BCR/ABL transcripts were analyzed by PCR. In the second part of the test, cell samples containing various concentrations of BCR/ABL-positive cells were analyzed by RT-PCR. Overall PCR sensitivity was sufficient in approximately 90% of the tests, but a significant number of false positive results were obtained. There were significant differences in sensitivity in the cell-based analysis between the various participants. The results are discussed, and proposals are made regarding the choice of primers, controls, conditions for RNA extraction and reverse transcription.
Testing and Analysis Validation of a Metallic Repair Applied to a PRSEUS Tension Panel
NASA Technical Reports Server (NTRS)
Przekop, Adam; Jegley, Dawn C.
2013-01-01
A design and analysis of a repair concept applicable to a stiffened composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure was recently completed. The damage scenario considered was a midbay-to-midbay saw-cut with a severed stiffener, flange and skin. Advanced modeling techniques such as mesh-independent definition of compliant fasteners and elastic-plastic material properties for metal parts were utilized in the finite element analysis supporting the design effort. A bolted metallic repair was selected so that it could be easily applied in the operational environment. The present work describes results obtained from a tension panel test conducted to validate both the repair concept and finite element analysis techniques used in the design effort. The test proved that the proposed repair concept is capable of sustaining load levels that are higher than those resulting from the current working stress allowables. This conclusion enables upward revision of the stress allowables that had been kept at an overly-conservative level due to concerns associated with repairability of the panels. Correlation of test data with finite element analysis results is also presented and assessed.
ERIC Educational Resources Information Center
McFarland, Dennis J.
2014-01-01
Purpose: Factor analysis is a useful technique to aid in organizing multivariate data characterizing speech, language, and auditory abilities. However, knowledge of the limitations of factor analysis is essential for proper interpretation of results. The present study used simulated test scores to illustrate some characteristics of factor…
Strain Modal Analysis of Small and Light Pipes Using Distributed Fibre Bragg Grating Sensors
Huang, Jun; Zhou, Zude; Zhang, Lin; Chen, Juntao; Ji, Chunqian; Pham, Duc Truong
2016-01-01
Vibration fatigue failure is a critical problem of hydraulic pipes under severe working conditions. Strain modal testing of small and light pipes is a good option for dynamic characteristic evaluation, structural health monitoring and damage identification. Unique features such as small size, light weight, and high multiplexing capability enable Fibre Bragg Grating (FBG) sensors to measure structural dynamic responses where sensor size and placement are critical. In this paper, experimental strain modal analysis of pipes using distributed FBG sensors ispresented. Strain modal analysis and parameter identification methods are introduced. Experimental strain modal testing and finite element analysis for a cantilever pipe have been carried out. The analysis results indicate that the natural frequencies and strain mode shapes of the tested pipe acquired by FBG sensors are in good agreement with the results obtained by a reference accelerometer and simulation outputs. The strain modal parameters of a hydraulic pipe were obtained by the proposed strain modal testing method. FBG sensors have been shown to be useful in the experimental strain modal analysis of small and light pipes in mechanical, aeronautic and aerospace applications. PMID:27681728
Analysis of helicopter noise data using international helicopter noise certification procedures
DOT National Transportation Integrated Search
1986-03-31
This report documents the results of a Federal Aviation Administration (FAA) noise measurement flight test program involving seven helicopters and established noise levels using the basic testing, reduction and analysis procedures specified by the In...
Flight and ground tests of a very low density elastomeric ablative material
NASA Technical Reports Server (NTRS)
Olsen, G. C.; Chapman, A. J., III
1972-01-01
A very low density ablative material, a silicone-phenolic composite, was flight tested on a recoverable spacecraft launched by a Pacemaker vehicle system; and, in addition, it was tested in an arc heated wind tunnel at three conditions which encompassed most of the reentry heating conditions of the flight tests. The material was composed, by weight, of 71 percent phenolic spheres, 22.8 percent silicone resin, 2.2 percent catalyst, and 4 percent silica fibers. The tests were conducted to evaluate the ablator performance in both arc tunnel and flight tests and to determine the predictability of the albator performance by using computed results from an existing one-dimensional numerical analysis. The flight tested ablator experienced only moderate surface recession and retained a smooth surface except for isolated areas where the char was completely removed, probably following reentry and prior to or during recovery. Analytical results show good agreement between arc tunnel and flight test results. The thermophysical properties used in the analysis are tabulated.
Development of HAN-based Liquid Propellant Thruster
NASA Astrophysics Data System (ADS)
Hisatsune, K.; Izumi, J.; Tsutaya, H.; Furukawa, K.
2004-10-01
Many of propellants that are applied to the conventional spacecraft propulsion system are toxic propellants. Because of its toxicity, considering the environmental pollution or safety on handling, it will be necessary to apply the "green" propellant to the spacecraft propulsion system. The purpose of this study is to apply HAN based liquid propellant (LP1846) to mono propellant thruster. Compared to the hydrazine that is used in conventional mono propellant thruster, HAN based propellant is not only lower toxic but also can obtain higher specific impulse. Moreover, HAN based propellant can be decomposed by the catalyst. It means there are the possibility of applying to the mono propellant thruster that can leads to the high reliability of the propulsion system.[1],[2] However, there are two technical subjects, to apply HAN based propellant to the mono propellant thruster. One is the high combustion temperature. The catalyst will be damaged under high temperature condition. The other is the low catalytic activity. It is the serious problem on application of HAN based propellant to the mono propellant thruster that is used for attitude control of spacecraft. To improve the catalytic activity of HAN based propellant, it is necessary to screen the best catalyst for HAN based propellant. The adsorption analysis is conducted by Monte Carlo Simulation to screen the catalyst metal for HAN and TEAN. The result of analysis shows the Iridium is the best catalyst metal for HAN and TEAN. Iridium is the catalyst metal that is used at conventional mono propellant thruster catalyst Shell405. Then, to confirm the result of analysis, the reaction test about catalyst is conducted. The result of this test is the same as the result of adsorption analysis. That means the adsorption analysis is effective in screening the catalyst metal. At the evaluating test, the various types of carrier of catalyst are also compared to Shell 405 to improve catalytic activity. The test result shows the inorganic porous media is superior to Shell405 in catalytic activity. Next, the catalyst life with HAN based propellant (LP1846) is evaluated. The Shell405 and inorganic porous media catalyst are compared at the life test. The test result shows the inorganic porous media catalyst is superior to Shell405 in catalyst life. In this paper, the detail of the result of adsorption analysis and evaluating test are reported.
Pre-Test Analysis Predictions for the Shell Buckling Knockdown Factor Checkout Tests - TA01 and TA02
NASA Technical Reports Server (NTRS)
Thornburgh, Robert P.; Hilburger, Mark W.
2011-01-01
This report summarizes the pre-test analysis predictions for the SBKF-P2-CYL-TA01 and SBKF-P2-CYL-TA02 shell buckling tests conducted at the Marshall Space Flight Center (MSFC) in support of the Shell Buckling Knockdown Factor (SBKF) Project, NASA Engineering and Safety Center (NESC) Assessment. The test article (TA) is an 8-foot-diameter aluminum-lithium (Al-Li) orthogrid cylindrical shell with similar design features as that of the proposed Ares-I and Ares-V barrel structures. In support of the testing effort, detailed structural analyses were conducted and the results were used to monitor the behavior of the TA during the testing. A summary of predicted results for each of the five load sequences is presented herein.
Integrated Data Collection Analysis (IDCA) program--KClO 4/Dodecane Mixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and dodecane—KClO 4/dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be less sensitive to impact than RDX, and PETN, 2) less sensitive to friction than RDX and PETN, and 3) less sensitive to spark thanmore » RDX and PETN. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed and assigned to a phase transition of KClO 4. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less
NDARC - NASA Design and Analysis of Rotorcraft Validation and Demonstration
NASA Technical Reports Server (NTRS)
Johnson, Wayne
2010-01-01
Validation and demonstration results from the development of the conceptual design tool NDARC (NASA Design and Analysis of Rotorcraft) are presented. The principal tasks of NDARC are to design a rotorcraft to satisfy specified design conditions and missions, and then analyze the performance of the aircraft for a set of off-design missions and point operating conditions. The aircraft chosen as NDARC development test cases are the UH-60A single main-rotor and tail-rotor helicopter, the CH-47D tandem helicopter, the XH-59A coaxial lift-offset helicopter, and the XV-15 tiltrotor. These aircraft were selected because flight performance data, a weight statement, detailed geometry information, and a correlated comprehensive analysis model are available for each. Validation consists of developing the NDARC models for these aircraft by using geometry and weight information, airframe wind tunnel test data, engine decks, rotor performance tests, and comprehensive analysis results; and then comparing the NDARC results for aircraft and component performance with flight test data. Based on the calibrated models, the capability of the code to size rotorcraft is explored.
NASA Technical Reports Server (NTRS)
Proctor, Margaret P.; Gunter, Edgar J.
2007-01-01
A case study of a high-speed seal test rotor shows how rotor dynamic analysis can be used to diagnose the source of high vibrations and evaluate a proposed remedy. Experimental results are compared with the synchronous and non-synchronous whirl response analysis of a double overhung, high-speed seal test rotor with ball bearings supported in 5.84- and 12.7-mm-long, un-centered squeeze-film oil dampers. Test performance with the original damper of length 5.84 mm was marginal. Non-synchronous whirling occurred at the overhung seal test disk and there was a high amplitude synchronous response near the drive spline above 32,000 rpm. Nonlinear synchronous unbalance and time transient whirl studies were conducted on the seal test rotor with the original and extended damper lengths. With the original damper design, the nonlinear synchronous response showed that unbalance could cause damper lockup at 33,000 rpm. Alford cross-coupling forces were also included at the overhung seal test disk for the whirl analysis. Sub-synchronous whirling at the seal test disk was observed in the nonlinear time transient analysis. With the extended damper length of 12.7 mm, the sub-synchronous motion was eliminated and the rotor unbalance response was acceptable to 45,000 rpm with moderate rotor unbalance. Seal test rotor orbits and vibration levels with the extended squeeze film dampers showed smooth operation to 40,444 rpm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spore, J.W.; Cappiello, M.W.; Dotson, P.J.
The analytical support in 1985 for Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF), and Upper Plenum Test Facility (UPTF) tests involves the posttest analysis of 16 tests that have already been run in the CCTF and the SCTF and the pretest analysis of 3 tests to be performed in the UPTF. Posttest analysis is used to provide insight into the detailed thermal-hydraulic phenomena occurring during the refill and reflood tests performed in CCTF and SCTF. Pretest analysis is used to ensure that the test facility is operated in a manner consistent with the expected behavior of anmore » operating full-scale plant during an accident. To obtain expected behavior of a plant during an accident, two plant loss-of-coolant-accident (LOCA) calculations were performed: a 200% cold-leg-break LOCA calculation for a 2772 MW(t) Babcock and Wilcox plant and a 200% cold-leg-break LOCA calculation for a 3315 MW(t) Westinghouse plant. Detailed results are presented for several CCTF UPI tests and the Westinghouse plant analysis.« less
NASA Technical Reports Server (NTRS)
Gangwani, S. T.
1985-01-01
A reliable rotor aeroelastic analysis operational that correctly predicts the vibration levels for a helicopter is utilized to test various unsteady aerodynamics models with the objective of improving the correlation between test and theory. This analysis called Rotor Aeroelastic Vibration (RAVIB) computer program is based on a frequency domain forced response analysis which utilizes the transfer matrix techniques to model helicopter/rotor dynamic systems of varying degrees of complexity. The results for the AH-1G helicopter rotor were compared with the flight test data during high speed operation and they indicated a reasonably good correlation for the beamwise and chordwise blade bending moments, but for torsional moments the correlation was poor. As a result, a new aerodynamics model based on unstalled synthesized data derived from the large amplitude oscillating airfoil experiments was developed and tested.
A Finite Rate Chemical Analysis of Nitric Oxide Flow Contamination Effects on Scramjet Performance
NASA Technical Reports Server (NTRS)
Cabell, Karen F.; Rock, Kenneth E.
2003-01-01
The level of nitric oxide contamination in the test gas of the Langley Research Center Arc-Heated Scramjet Test Facility and the effect of the contamination on scramjet test engine performance were investigated analytically. A finite rate chemical analysis was performed to determine the levels of nitric oxide produced in the facility at conditions corresponding to Mach 6 to 8 flight simulations. Results indicate that nitric oxide levels range from one to three mole percent, corroborating previously obtained measurements. A three-stream combustor code with finite rate chemistry was used to investigate the effects of nitric oxide on scramjet performance. Results indicate that nitric oxide in the test gas causes a small increase in heat release and thrust performance for the test conditions investigated. However, a rate constant uncertainty analysis suggests that the effect of nitric oxide ranges from no net effect, to an increase of about 10 percent in thrust performance.
Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Data report
NASA Technical Reports Server (NTRS)
Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.
1982-01-01
Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116 K (-250 F), 294 K (70 F) and 561 K (550 F). Joint parameters evaluated are lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Advanced joint concepts were examined to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. The material properties of the high temperature adhesive, designated A7F, used for bonding were established. The bonded joint tests resulted in interlaminar shear or peel failures of the composite and there were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.
Evaluation of a Singular Value Decomposition Approach for Impact Dynamic Data Correlation
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Lyle, Karen H.; Lessard, Wendy B.
2003-01-01
Impact dynamic tests are used in the automobile and aircraft industries to assess survivability of occupants during crash, to assert adequacy of the design, and to gain federal certification. Although there is no substitute for experimental tests, analytical models are often developed and used to study alternate test conditions, to conduct trade-off studies, and to improve designs. To validate results from analytical predictions, test and analysis results must be compared to determine the model adequacy. The mathematical approach evaluated in this paper decomposes observed time responses into dominant deformation shapes and their corresponding contribution to the measured response. To correlate results, orthogonality of test and analysis shapes is used as a criterion. Data from an impact test of a composite fuselage is used and compared to finite element predictions. In this example, the impact response was decomposed into multiple shapes but only two dominant shapes explained over 85% of the measured response
Development of a facility using robotics for testing automation of inertial instruments
NASA Technical Reports Server (NTRS)
Greig, Joy Y.; Lamont, Gary B.; Biezad, Daniel J.; Lewantowicz, Zdsislaw H.; Greig, Joy Y.
1987-01-01
The Integrated Robotics System Simulation (ROBSIM) was used to evaluate the performance of the PUMA 560 arm as applied to testing of inertial sensors. Results of this effort were used in the design and development of a feasibility test environment using a PUMA 560 arm. The implemented facility demonstrated the ability to perform conventional static inertial instrument tests (rotation and tumble). The facility included an efficient data acquisitions capability along with a precision test servomechanism function resulting in various data presentations which are included in the paper. Analysis of inertial instrument testing accuracy, repeatability and noise characteristics are provided for the PUMA 560 as well as for other possible commercial arm configurations. Another integral aspect of the effort was an in-depth economic analysis and comparison of robot arm testing versus use of contemporary precision test equipment.
Application of software technology to automatic test data analysis
NASA Technical Reports Server (NTRS)
Stagner, J. R.
1991-01-01
The verification process for a major software subsystem was partially automated as part of a feasibility demonstration. The methods employed are generally useful and applicable to other types of subsystems. The effort resulted in substantial savings in test engineer analysis time and offers a method for inclusion of automatic verification as a part of regression testing.
The Use of Time Series Analysis and t Tests with Serially Correlated Data Tests.
ERIC Educational Resources Information Center
Nicolich, Mark J.; Weinstein, Carol S.
1981-01-01
Results of three methods of analysis applied to simulated autocorrelated data sets with an intervention point (varying in autocorrelation degree, variance of error term, and magnitude of intervention effect) are compared and presented. The three methods are: t tests; maximum likelihood Box-Jenkins (ARIMA); and Bayesian Box Jenkins. (Author/AEF)
Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari
2014-02-01
Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.
NASA Technical Reports Server (NTRS)
Yim, John T.; Soulas, George C.; Shastry, Rohit; Choi, Maria; Mackey, Jonathan A.; Sarver-Verhey, Timothy R.
2017-01-01
The service life assessment for NASA's Evolutionary Xenon Thruster is updated to incorporate the results from the successful and voluntarily early completion of the 51,184 hour long duration test which demonstrated 918 kg of total xenon throughput. The results of the numerous post-test investigations including destructive interrogations have been assessed against all of the critical known and suspected failure mechanisms to update the life and throughput expectations for each major component. Analysis results of two of the most acute failure mechanisms, namely pit-and-groove erosion and aperture enlargement of the accelerator grid, are not updated in this work but will be published at a future time after analysis completion.
Improve SSME power balance model
NASA Technical Reports Server (NTRS)
Karr, Gerald R.
1992-01-01
Effort was dedicated to development and testing of a formal strategy for reconciling uncertain test data with physically limited computational prediction. Specific weaknesses in the logical structure of the current Power Balance Model (PBM) version are described with emphasis given to the main routing subroutines BAL and DATRED. Selected results from a variational analysis of PBM predictions are compared to Technology Test Bed (TTB) variational study results to assess PBM predictive capability. The motivation for systematic integration of uncertain test data with computational predictions based on limited physical models is provided. The theoretical foundation for the reconciliation strategy developed in this effort is presented, and results of a reconciliation analysis of the Space Shuttle Main Engine (SSME) high pressure fuel side turbopump subsystem are examined.
Wind tunnel test IA300 analysis and results, volume 1
NASA Technical Reports Server (NTRS)
Kelley, P. B.; Beaufait, W. B.; Kitchens, L. L.; Pace, J. P.
1987-01-01
The analysis and interpretation of wind tunnel pressure data from the Space Shuttle wind tunnel test IA300 are presented. The primary objective of the test was to determine the effects of the Space Shuttle Main Engine (SSME) and the Solid Rocket Booster (SRB) plumes on the integrated vehicle forebody pressure distributions, the elevon hinge moments, and wing loads. The results of this test will be combined with flight test results to form a new data base to be employed in the IVBC-3 airloads analysis. A secondary objective was to obtain solid plume data for correlation with the results of gaseous plume tests. Data from the power level portion was used in conjunction with flight base pressures to evaluate nominal power levels to be used during the investigation of changes in model attitude, eleveon deflection, and nozzle gimbal angle. The plume induced aerodynamic loads were developed for the Space Shuttle bases and forebody areas. A computer code was developed to integrate the pressure data. Using simplified geometrical models of the Space Shuttle elements and components, the pressure data were integrated to develop plume induced force and moments coefficients that can be combined with a power-off data base to develop a power-on data base.
Effect of the statin therapy on biochemical laboratory tests--a chemometrics study.
Durceková, Tatiana; Mocák, Ján; Boronová, Katarína; Balla, Ján
2011-01-05
Statins are the first-line choice for lowering total and LDL cholesterol levels and very important medicaments for reducing the risk of coronary artery disease. The aim of this study is therefore assessment of the results of biochemical tests characterizing the condition of 172 patients before and after administration of statins. For this purpose, several chemometric tools, namely principal component analysis, cluster analysis, discriminant analysis, logistic regression, KNN classification, ROC analysis, descriptive statistics and ANOVA were used. Mutual relations of 11 biochemical laboratory tests, the patient's age and gender were investigated in detail. Achieved results enable to evaluate the extent of the statin treatment in each individual case. They may also help in monitoring the dynamic progression of the disease. Copyright © 2010 Elsevier B.V. All rights reserved.
Examining evolving performance on the Force Concept Inventory using factor analysis
NASA Astrophysics Data System (ADS)
Semak, M. R.; Dietz, R. D.; Pearson, R. H.; Willis, C. W.
2017-06-01
The application of factor analysis to the Force Concept Inventory (FCI) has proven to be problematic. Some studies have suggested that factor analysis of test results serves as a helpful tool in assessing the recognition of Newtonian concepts by students. Other work has produced at best ambiguous results. For the FCI administered as a pre- and post-test, we see factor analysis as a tool by which the changes in conceptual associations made by our students may be gauged given the evolution of their response patterns. This analysis allows us to identify and track conceptual linkages, affording us insight as to how our students have matured due to instruction. We report on our analysis of 427 pre- and post-tests. The factor models for the pre- and post-tests are explored and compared along with the methodology by which these models were fit to the data. The post-test factor pattern is more aligned with an expert's interpretation of the questions' content, as it allows for a more readily identifiable relationship between factors and physical concepts. We discuss this evolution in the context of approaching the characteristics of an expert with force concepts. Also, we find that certain test items do not significantly contribute to the pre- or post-test factor models and attempt explanations as to why this is so. This may suggest that such questions may not be effective in probing the conceptual understanding of our students.
Sharma, Vishal; Sundar, Sudha S; Breheny, Katie; Monahan, Mark; Sutton, Andrew John
2016-06-01
There are multiple tests available that can help diagnose ovarian cancer, and the cost-effective analysis of these diagnostic interventions is essential for making well-informed decisions regarding resource allocation. There are multiple factors that can impact on the conclusions drawn from economic evaluations including test accuracy, the impact of the testing pathway on patient costs and outcomes, and delays along the ovarian cancer test-treat pathway. The objective of this study was to evaluate how test accuracy, the choice of perspective, and delays along the testing and diagnostic pathway have been incorporated in economic evaluations of testing for ovarian cancer. A systematic review of published literature was undertaken to identify economic evaluations (eg, cost-effectiveness, cost-utility analysis) focused on testing and diagnosis for ovarian cancer. Seven studies met the inclusion criteria. Six studies incorporated test accuracy and its impact on patients to some extent. Four studies adopted a societal perspective, but only one considered the costs incurred by patients on the testing and diagnosis pathway. Where delays on the testing pathway were incorporated into the analysis, these were frequently due to false-negative test results leading to delays in patients accessing treatment. Any anxiety that patients might experience as a result of a positive test was not considered in these studies. The impact on patients of receiving a positive test in terms of anxiety and the costs incurred by patients having to attend for testing and diagnosis are rarely considered. Delays along the testing and diagnosis pathway can have a major effect on patient outcomes, and it is important that these are acknowledged in economic evaluations focused on testing. Future economic analysis should incorporate these key determinants in order that diagnostic tests for ovarian cancer can be robustly evaluated.
pcr: an R package for quality assessment, analysis and testing of qPCR data
Ahmed, Mahmoud
2018-01-01
Background Real-time quantitative PCR (qPCR) is a broadly used technique in the biomedical research. Currently, few different analysis models are used to determine the quality of data and to quantify the mRNA level across the experimental conditions. Methods We developed an R package to implement methods for quality assessment, analysis and testing qPCR data for statistical significance. Double Delta CT and standard curve models were implemented to quantify the relative expression of target genes from CT in standard qPCR control-group experiments. In addition, calculation of amplification efficiency and curves from serial dilution qPCR experiments are used to assess the quality of the data. Finally, two-group testing and linear models were used to test for significance of the difference in expression control groups and conditions of interest. Results Using two datasets from qPCR experiments, we applied different quality assessment, analysis and statistical testing in the pcr package and compared the results to the original published articles. The final relative expression values from the different models, as well as the intermediary outputs, were checked against the expected results in the original papers and were found to be accurate and reliable. Conclusion The pcr package provides an intuitive and unified interface for its main functions to allow biologist to perform all necessary steps of qPCR analysis and produce graphs in a uniform way. PMID:29576953
Design/Analysis of the JWST ISIM Bonded Joints for Survivability at Cryogenic Temperatures
NASA Technical Reports Server (NTRS)
Bartoszyk, Andrew; Johnston, John; Kaprielian, Charles; Kuhn, Jonathan; Kunt, Cengiz; Rodini,Benjamin; Young, Daniel
1990-01-01
A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite bonded joints below the cryogenic temperature of 30K (-405 F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to M55J/954-6 and T300/954-6 hybrid composite tubes (75mm square). Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.
Test Cases for Modeling and Validation of Structures with Piezoelectric Actuators
NASA Technical Reports Server (NTRS)
Reaves, Mercedes C.; Horta, Lucas G.
2001-01-01
A set of benchmark test articles were developed to validate techniques for modeling structures containing piezoelectric actuators using commercially available finite element analysis packages. The paper presents the development, modeling, and testing of two structures: an aluminum plate with surface mounted patch actuators and a composite box beam with surface mounted actuators. Three approaches for modeling structures containing piezoelectric actuators using the commercially available packages: MSC/NASTRAN and ANSYS are presented. The approaches, applications, and limitations are discussed. Data for both test articles are compared in terms of frequency response functions from deflection and strain data to input voltage to the actuator. Frequency response function results using the three different analysis approaches provided comparable test/analysis results. It is shown that global versus local behavior of the analytical model and test article must be considered when comparing different approaches. Also, improper bonding of actuators greatly reduces the electrical to mechanical effectiveness of the actuators producing anti-resonance errors.
Brothman, Arthur R; Dolan, Michelle M; Goodman, Barbara K; Park, Jonathan P; Persons, Diane L; Saxe, Debra F; Tepperberg, James H; Tsuchiya, Karen D; Van Dyke, Daniel L; Wilson, Kathleen S; Wolff, Daynna J; Theil, Karl S
2011-09-01
To evaluate the feasibility of administering a newly established proficiency test offered through the College of American Pathologists and the American College of Medical Genetics for genomic copy number assessment by microarray analysis, and to determine the reproducibility and concordance among laboratory results from this test. Surveys were designed through the Cytogenetic Resource Committee of the two colleges to assess the ability of testing laboratories to process DNA samples provided and interpret results. Supplemental questions were asked with each Survey to determine laboratory practice trends. Twelve DNA specimens, representing 2 pilot and 10 Survey challenges, were distributed to as many as 74 different laboratories, yielding 493 individual responses. The mean consensus for matching result interpretations was 95.7%. Responses to supplemental questions indicate that the number of laboratories offering this testing is increasing, methods for analysis and evaluation are becoming standardized, and array platforms used are increasing in probe density. The College of American Pathologists/American College of Medical Genetics proficiency testing program for copy number assessment by cytogenomic microarray is a successful and efficient mechanism for assessing interlaboratory reproducibility. This will provide laboratories the opportunity to evaluate their performance and assure overall accuracy of patient results. The high level of concordance in laboratory responses across all testing platforms by multiple facilities highlights the robustness of this technology.
Gunaydin, Gurkan; Citaker, Seyit; Meray, Jale; Cobanoglu, Gamze; Gunaydin, Ozge Ece; Hazar Kanik, Zeynep
2016-11-01
Validation of a self-report questionnaire. The purpose of this study was to investigate adaptation, validity, and reliability of the Turkish version of the Bournemouth Questionnaire. Low back pain is one of the most frequent disorders leading to activity limitation. This pain affects most of people in their lives. The most important point to evaluate patient's functional abilities and to decide a successful therapy procedure is to manage the assessment questionnaires precisely. One hundred ten patients with chronic low back pain were included in present study. To assess reliability, test-retest and internal consistency analyses were applied. The results of test-retest analysis were assessed by using Intraclass Correlation Coefficient method (95% confidence interval). For internal consistency, Cronbach alpha value was calculated. Validity of the questionnaire was assessed in terms of construct validity. For construct validity, factor analysis and convergent validity were tested. For convergent validity, total points of the Bournemouth Questionnaire were assessed with the total points of Quebec Back Pain Disability Scale and Roland Morris Disability Questionnaire by using Pearson correlation coefficient analysis. Cronbach alpha value was found 0.914, showing that this questionnaire has high internal consistency. The results of test-retest analysis were varying between 0.851 and 0.927, which shows that test-retest results are highly correlated. Factor analysis test indicated that this questionnaire had one factor. Pearson correlation coefficient of the Bournemouth Questionnaire with Roland Morris Disability Questionnaire was calculated 0.703 and it was found with Quebec Back Pain Disability Scale is 0.659. These results showed that the Bournemouth Questionnaire is very good correlated with Roland Morris Disability Questionnaire and Quebec Back Pain Disability Scale. The Turkish version of the Bournemouth Questionnaire is valid and reliable. 3.
Profiles of Learning. The Basic Skills Testing Program in New South Wales: 1989.
ERIC Educational Resources Information Center
Masters, Geofferey; And Others
This publication on the New South Wales' Basic Skills Testing Program (BSTP) describes the development of the program's tests, the analysis of students' results, and the communication of results to parents, teachers, and schools. In BSTP tests, basic skills are defined not as low-level, rudimentary survival skills, but as major areas of learning…
Yoo, Doo Han; Lee, Jae Shin
2016-07-01
[Purpose] This study examined the clinical usefulness of the clock drawing test applying Rasch analysis for predicting the level of cognitive impairment. [Subjects and Methods] A total of 187 stroke patients with cognitive impairment were enrolled in this study. The 187 patients were evaluated by the clock drawing test developed through Rasch analysis along with the mini-mental state examination of cognitive evaluation tool. An analysis of the variance was performed to examine the significance of the mini-mental state examination and the clock drawing test according to the general characteristics of the subjects. Receiver operating characteristic analysis was performed to determine the cutoff point for cognitive impairment and to calculate the sensitivity and specificity values. [Results] The results of comparison of the clock drawing test with the mini-mental state showed significant differences in according to gender, age, education, and affected side. A total CDT of 10.5, which was selected as the cutoff point to identify cognitive impairement, showed a sensitivity, specificity, Youden index, positive predictive, and negative predicive values of 86.4%, 91.5%, 0.8, 95%, and 88.2%. [Conclusion] The clock drawing test is believed to be useful in assessments and interventions based on its excellent ability to identify cognitive disorders.
NASA Technical Reports Server (NTRS)
Quade, D. A.
1978-01-01
The airplane flutter and maneuver-gust load analysis results obtained during B-52B drop test vehicle configuration (with fins) evaluation are presented. These data are presented as supplementary data to that given in Volume 1 of this document. A brief mathematical description of airspeed notation and gust load factor criteria are provided as a help to the user. References are defined which provide mathematical description of the airplane flutter and load analysis techniques. Air-speed-load factor diagrams are provided for the airplane weight configurations reanalyzed for finned drop test vehicle configuration.
NASA Technical Reports Server (NTRS)
Connelly, Joseph; Blake, Peter; Jones, Joycelyn
2008-01-01
The authors report operational upgrades and streamlined data analysis of a commissioned electronic speckle interferometer (ESPI) in a permanent in-house facility at NASA's Goddard Space Flight Center. Our ESPI was commercially purchased for use by the James Webb Space Telescope (JWST) development team. We have quantified and reduced systematic error sources, improved the software operability with a user-friendly graphic interface, developed an instrument simulator, streamlined data analysis for long-duration testing, and implemented a turn-key approach to speckle interferometry. We also summarize results from a test of the JWST support structure (previously published), and present new results from several pieces of test hardware at various environmental conditions.
Experimental and analytical assessment of the thermal behavior of spiral bevel gears
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.; Kicher, Thomas P.
1995-01-01
An experimental and analytical study of spiral bevel gears operating in an aerospace environment has been performed. Tests were conducted within a closed loop test stand at NASA Lewis Research Center. Tests were conducted to 537 kW (720 hp) at 14,400 rpm. The effects of various operating conditions on spiral bevel gear steady state and transient temperature are presented. Also, a three-dimensional analysis of the thermal behavior was conducted using a nonlinear finite element analysis computer code. The analysis was compared to the experimental results attained in this study. The results agreed well with each other for the cases compared and were no more than 10 percent different in magnitude.
ERIC Educational Resources Information Center
Eastman-Mueller, Heather P.; Oswalt, Sara B.
2017-01-01
Objective: To conduct a trend analysis of Pap test practices, Pap test results and related women's services and guidelines of college health centers. Participants: College health centers who participated in the annual ACHA Pap Test and STI (sexually transmitted infection) Survey years 2004-2014 (n ranged from 127 to 181 depending on year).…
Development and Flight Testing of an Autonomous Landing Gear Health-Monitoring System
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Taylor, B. Douglas; Brett, Rube R.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.
2003-01-01
Development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation; and, data acquisition, storage and retrieval.
A reliable unipedal stance test for the assessment of balance using a force platform.
Ponce-González, J G; Sanchis-Moysi, J; González-Henriquez, J J; Arteaga-Ortiz, R; Calbet, J A L; Dorado, C
2014-02-01
The aim was to develop a unipedal stance test for the assessment of balance using a force platform. A single-leg balance test was conducted in 23 students (mean ± SD) age: 23 ± 3 years) in a standard position limiting the movement of the arms and non-supporting leg. Six attempts, with both the jumping (JL) and the contralateral leg (CL), were performed under 3 conditions: 1) eyes opened; 2) eyes closed; 3) eyes opened and executing a precision task. The same protocol was repeated two-week apart. The mean and the best result of the six attempts performed each day were taken as representative of balance. The speed of the centre of pressure (CP-Speed) showed excellent reliability for the "best result" analysis in all tests (ICCs 0.87-0.97), except in the test with the eyes closed performed on the CL (ICC<0.4). The CP-Speed had better reliability with the "best result" than with the "mean result" analysis (P<0.05), whilst no significant differences were observed between the JL and the CL (P=0.71 and P=0.96 for mean and best results analysis, respectively). A lower dispersion in the Bland and Altman graph was observed with the eyes opened than closed, and the dynamic test. The single-leg stance balance test proposed is a reliable method to assess balance, especially when performed in a static position, with the eyes opened and using the best result of six attempts as reference, independently of the stance leg.
Pyrolysis of coal, biomass and their blends: performance assessment by thermogravimetric analysis.
Ferrara, Francesca; Orsini, Alessandro; Plaisant, Alberto; Pettinau, Alberto
2014-11-01
With the aim to support the experimental tests in a gasification pilot plant, the thermal decomposition of coal, biomass and their mixtures has been carried out through a thermogravimetric analysis (TGA) and a simplified kinetic analysis. The TGA of pure fuels indicates the low reactivity of South African coal and the relatively high reactivity of Sardinian Sulcis coal during pyrolysis. Among the tested fuels, biomass (stone pine wood chips) is the most reactive one. These results fully confirm those obtained during the experimental tests in the gasification pilot plant. As for the fuel blends, the analysis shows that the synergic effects between the considered coals and biomass are negligible when they are co-pyrolyzed. The results of the analysis confirm that TGA could be very useful to generally predict the gasification performance and to optimize the experimental campaigns in pilot-scale gasification plants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Enhanced sulfidation xanthate flotation of malachite using ammonium ions as activator.
Wu, Dandan; Ma, Wenhui; Mao, Yingbo; Deng, Jiushuai; Wen, Shuming
2017-05-18
In this study, ammonium ion was used to enhance the sulfidation flotation of malachite. The effect of ammonium ion on the sulfidation flotation of malachite was investigated using microflotation test, inductively coupled plasma (ICP) analysis, zeta potential measurements, and scanning electron microscope analysis (SEM). The results of microflotation test show that the addition of sodium sulfide and ammonium sulfate resulted in better sulfidation than the addition of sodium sulfide alone. The results of ICP analysis indicate that the dissolution of enhanced sulfurized malachite surface is significantly decreased. Zeta potential measurements indicate that a smaller isoelectric point value and a large number of copper-sulfide films formed on the malachite surface by enhancing sulfidation resulted in a large amount of sodium butyl xanthate absorbed onto the enhanced sulfurized malachite surface. EDS semi-quantitative analysis and XPS analysis show that malachite was easily sulfurized by sodium sulfide with ammonium ion. These results show that the addition of ammonium ion plays a significant role in the sulfidation of malachite and results in improved flotation performance.
Beltrame, Anna; Guerriero, Massimo; Angheben, Andrea; Gobbi, Federico; Requena-Mendez, Ana; Zammarchi, Lorenzo; Formenti, Fabio; Perandin, Francesca; Bisoffi, Zeno
2017-01-01
Background Schistosomiasis is a neglected infection affecting millions of people, mostly living in sub-Saharan Africa. Morbidity and mortality due to chronic infection are relevant, although schistosomiasis is often clinically silent. Different diagnostic tests have been implemented in order to improve screening and diagnosis, that traditionally rely on parasitological tests with low sensitivity. Aim of this study was to evaluate the accuracy of different tests for the screening of schistosomiasis in African migrants, in a non endemic setting. Methodology/Principal findings A retrospective study was conducted on 373 patients screened at the Centre for Tropical Diseases (CTD) in Negrar, Verona, Italy. Biological samples were tested with: stool/urine microscopy, Circulating Cathodic Antigen (CCA) dipstick test, ELISA, Western blot, immune-chromatographic test (ICT). Test accuracy and predictive values of the immunological tests were assessed primarily on the basis of the results of microscopy (primary reference standard): ICT and WB resulted the test with highest sensitivity (94% and 92%, respectively), with a high NPV (98%). CCA showed the highest specificity (93%), but low sensitivity (48%). The analysis was conducted also using a composite reference standard, CRS (patients classified as infected in case of positive microscopy and/or at least 2 concordant positive immunological tests) and Latent Class Analysis (LCA). The latter two models demonstrated excellent agreement (Cohen’s kappa: 0.92) for the classification of the results. In fact, they both confirmed ICT as the test with the highest sensitivity (96%) and NPV (97%), moreover PPV was reasonably good (78% and 72% according to CRS and LCA, respectively). ELISA resulted the most specific immunological test (over 99%). The ICT appears to be a suitable screening test, even when used alone. Conclusions The rapid test ICT was the most sensitive test, with the potential of being used as a single screening test for African migrants. PMID:28582412
Evaluation and simplification of the occupational slip, trip and fall risk-assessment test
NAKAMURA, Takehiro; OYAMA, Ichiro; FUJINO, Yoshihisa; KUBO, Tatsuhiko; KADOWAKI, Koji; KUNIMOTO, Masamizu; ODOI, Haruka; TABATA, Hidetoshi; MATSUDA, Shinya
2016-01-01
Objective: The purpose of this investigation is to evaluate the efficacy of the occupational slip, trip and fall (STF) risk assessment test developed by the Japan Industrial Safety and Health Association (JISHA). We further intended to simplify the test to improve efficiency. Methods: A previous cohort study was performed using 540 employees aged ≥50 years who took the JISHA’s STF risk assessment test. We conducted multivariate analysis using these previous results as baseline values and answers to questionnaire items or score on physical fitness tests as variables. The screening efficiency of each model was evaluated based on the obtained receiver operating characteristic (ROC) curve. Results: The area under the ROC obtained in multivariate analysis was 0.79 when using all items. Six of the 25 questionnaire items were selected for stepwise analysis, giving an area under the ROC curve of 0.77. Conclusion: Based on the results of follow-up performed one year after the initial examination, we successfully determined the usefulness of the STF risk assessment test. Administering a questionnaire alone is sufficient for screening subjects at risk of STF during the subsequent one-year period. PMID:27021057
Finite Element Model Calibration Approach for Ares I-X
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Reaves, Mercedes C.; Buehrle, Ralph D.; Templeton, Justin D.; Lazor, Daniel R.; Gaspar, James L.; Parks, Russel A.; Bartolotta, Paul A.
2010-01-01
Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of nonconventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pre-test predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.
Verification test results of Apollo stabilization and control systems during undocked operations
NASA Technical Reports Server (NTRS)
Copeland, E. L.; Haken, R. L.
1974-01-01
The results are presented of analysis and simulation testing of both the Skylark 1 reaction control system digital autopilot (RCS DAP) and the thrust vector control (TVC) autopilot for use during the undocked portions of the Apollo/Soyuz Test Project Mission. The RCS DAP testing was performed using the Skylab Functional Simulator (SLFS), a digital computer program capable of simulating the Apollo and Skylab autopilots along with vehicle dynamics including bending and sloshing. The model is used to simulate three-axis automatic maneuvers along with pilot controlled manual maneuvers using the RCS DAP. The TVC autopilot was tested in two parts. A classical stability analysis was performed on the vehicle considering the effects of structural bending and sloshing when under control of the TVC autopilot. The time response of the TVC autopilot was tested using the SLFS. Results indicate that adequate performance stability margins can be expected for the CSM/DM configuration when under the control of the Apollo control systems tested.
Mechanical Properties of Friction Stir Welds in A12195-T8
NASA Technical Reports Server (NTRS)
Kinchen, David G.; Li, Zhixian; Adams, Glynn P.
1999-01-01
An extensive study of the mechanical properties of friction stir welded Al-Li 2195 has been conducted by Lockheed Martin Michoud Space Systems under contract to NASA. The study was part of a development program in which weld parameters were defined for using FSW to assemble large-scale aluminum cryogenic tanks. In excess of 300 feet of 0.320 in. gage plate material was welded and tested. The tests include room temperature and cryogenic temperature tensile tests and surface crack tension (SCT) tests, nondestructive evaluation, metallurgical studies, and photostress analysis. The results of the testing demonstrated improved mechanical properties with FSW as compared to typical fusion welding processes. Increases in ultimate tensile strength, cryogenic enhancement and elongation were observed with the tensile test results. Increased fracture toughness was observed with the SCT results. Nondestructive evaluations were conducted on all welded Joints. No volumetric defects were indicated. Surface indications on the root side of the welds did not significantly affect weld strength. The results of the nondestructive evaluations were confirmed via metallurgical studies. Photostress analysis revealed strain concentrations in multi-pass and heat-repaired FSW's. Details of the tests and results are presented.
Assessing Computer Literacy: A Validated Instrument and Empirical Results.
ERIC Educational Resources Information Center
Gabriel, Roy M.
1985-01-01
Describes development of a comprehensive computer literacy assessment battery for K-12 curriculum based on objectives of a curriculum implemented in the Worldwide Department of Defense Dependents Schools system. Test development and field test data are discussed and a correlational analysis which assists in interpretation of test results is…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pytel, K.; Mieleszczenko, W.; Lechniak, J.
2010-03-01
The presented paper contains neutronic and thermal-hydraulic (for steady and unsteady states) calculation results prepared to support annex to Safety Analysis Report for MARIA reactor in order to obtain approval for program of testing low-enriched uranium (LEU) lead test fuel assemblies (LTFA) manufactured by CERCA. This includes presentation of the limits and operational constraints to be in effect during the fuel testing investigations. Also, the scope of testing program (which began in August 2009), including additional measurements and monitoring procedures, is described.
2017-03-01
proposed. Expected profiles can incorporate a level of overdesign. Finally, the Design Integrity measuring techniques are applied to five Test Article ...Inserted into Test System Table 2 presents the results of the analysis applied to each of the test article designs. Each of the domains are...the lowest integrities. Based on the analysis, the DI metric shows measurable differentiation between all five Test Article Error Location Error
Filament wound rocket motor chambers
NASA Technical Reports Server (NTRS)
1976-01-01
The design, analysis, fabrication and testing of a Kevlar-49/HBRF-55A filament wound chamber is reported. The chamber was fabricated and successfully tested to 80% of the design burst pressure. Results of the data reduction and analysis from the hydrotest indicate that the chamber design and fabrication techniques used for the chamber were adequate and the chamber should perform adequately in a static test.
Loading tests of a wing structure for a hypersonic aircraft
NASA Technical Reports Server (NTRS)
Fields, R. A.; Reardon, L. F.; Siegel, W. H.
1980-01-01
Room-temperature loading tests were conducted on a wing structure designed with a beaded panel concept for a Mach 8 hypersonic research airplane. Strain, stress, and deflection data were compared with the results of three finite-element structural analysis computer programs and with design data. The test program data were used to evaluate the structural concept and the methods of analysis used in the design. A force stiffness technique was utilized in conjunction with load conditions which produced various combinations of panel shear and compression loading to determine the failure envelope of the buckling critical beaded panels The force-stiffness data did not result in any predictions of buckling failure. It was, therefore, concluded that the panels were conservatively designed as a result of design constraints and assumptions of panel eccentricities. The analysis programs calculated strains and stresses competently. Comparisons between calculated and measured structural deflections showed good agreement. The test program offered a positive demonstration of the beaded panel concept subjected to room-temperature load conditions.
Rocket-Based Combined Cycle Engine Technology Development: Inlet CFD Validation and Application
NASA Technical Reports Server (NTRS)
DeBonis, J. R.; Yungster, S.
1996-01-01
A CFD methodology has been developed for inlet analyses of Rocket-Based Combined Cycle (RBCC) Engines. A full Navier-Stokes analysis code, NPARC, was used in conjunction with pre- and post-processing tools to obtain a complete description of the flow field and integrated inlet performance. This methodology was developed and validated using results from a subscale test of the inlet to a RBCC 'Strut-Jet' engine performed in the NASA Lewis 1 x 1 ft. supersonic wind tunnel. Results obtained from this study include analyses at flight Mach numbers of 5 and 6 for super-critical operating conditions. These results showed excellent agreement with experimental data. The analysis tools were also used to obtain pre-test performance and operability predictions for the RBCC demonstrator engine planned for testing in the NASA Lewis Hypersonic Test Facility. This analysis calculated the baseline fuel-off internal force of the engine which is needed to determine the net thrust with fuel on.
Integrated Data Collection Analysis (IDCA) Program - KClO 4/Carbon Mixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and activated carbon—KClO 4/C mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be insensitive to impact, friction, and thermal stimulus, and somewhat sensitive to spark discharge. This effort, funded by the Department of Homeland Security (DHS), ultimately will putmore » the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/carbon mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less
Analysis on pile testing results of post-grouting bored pile
NASA Astrophysics Data System (ADS)
Zheng, A. R.
2017-04-01
Based on static load test results, the bearing capacity of bored piles with pile-toe and pile-shaft post-grouting has been analyzed. The analysis reveals that: with post-grouting, the interface between pile and surrounding soil are strengthened and the relative sliding displacement in between is reduced; end resistance of pile is enhanced and can be mobilized at earlier stage with smaller sliding displacement. As a result, the performance of bored pile is improved with increased bearing capacity and reduced settlement.
Computer Administering of the Psychological Investigations: Set-Relational Representation
NASA Astrophysics Data System (ADS)
Yordzhev, Krasimir
Computer administering of a psychological investigation is the computer representation of the entire procedure of psychological assessments - test construction, test implementation, results evaluation, storage and maintenance of the developed database, its statistical processing, analysis and interpretation. A mathematical description of psychological assessment with the aid of personality tests is discussed in this article. The set theory and the relational algebra are used in this description. A relational model of data, needed to design a computer system for automation of certain psychological assessments is given. Some finite sets and relation on them, which are necessary for creating a personality psychological test, are described. The described model could be used to develop real software for computer administering of any psychological test and there is full automation of the whole process: test construction, test implementation, result evaluation, storage of the developed database, statistical implementation, analysis and interpretation. A software project for computer administering personality psychological tests is suggested.
PSK Shift Timing Information Detection Using Image Processing and a Matched Filter
2009-09-01
phase shifts are enhanced. Develop, design, and test the resulting phase shift identification scheme. xx Develop, design, and test an optional...and the resulting phase shift identification algorithm is investigated for SNR levels in the range -2dB to 12 dB. Detection performances are derived...test the resulting phase shift identification scheme. Develop, design, and test an optional analysis window overlapping technique to improve phase
Safety diagnosis: are we doing a good job?
Park, Peter Y; Sahaji, Rajib
2013-03-01
Collision diagnosis is the second step in the six-step road safety management process described in the AASHTO Highway Safety Manual (HSM). Diagnosis is designed to identify a dominant or abnormally high proportion of particular collision configurations (e.g., rear end, right angle, etc.) at a target location. The primary diagnosis method suggested in the HSM is descriptive data analysis. This type of analysis relies on, for example, pie charts, histograms, and/or collision diagrams. Using location specific collision data (e.g., collision frequency per collision configuration for a target location), safety engineers identify (the most) frequent collision configurations. Safety countermeasures are then likely to concentrate on preventing the selected collision configurations. Although its real-world application in engineering practice is limited, an additional collision diagnosis method, known as the beta-binomial (BB) test, is also presented as the secondary diagnosis tool in the HSM. The BB test compares the proportion of a particular collision configuration observed at one location with the proportion of the same collision configuration found at other reference locations which are similar to the target location in terms of selected traffic and roadway characteristics (e.g., traffic volume, traffic control, and number of lanes). This study compared the outcomes obtained from descriptive data analysis and the BB test, and investigates two questions: (1) Do descriptive data analysis and the BB tests produce the same results (i.e., do they select the same collision configurations at the same locations)? and (2) If the tests produce different results, which result should be adopted in engineering practice? This study's analysis was based on a sample of the most recent five years (2005-2009) of collision and roadway configuration data for 143 signalized intersections in the City of Saskatoon, Saskatchewan. The study results show that the BB test's role in diagnosing safety concerns in road safety engineering projects such as safety review projects for existing roadways may be just as important as the descriptive data analysis method. Copyright © 2012 Elsevier Ltd. All rights reserved.
Meta‐analysis of test accuracy studies using imputation for partial reporting of multiple thresholds
Deeks, J.J.; Martin, E.C.; Riley, R.D.
2017-01-01
Introduction For tests reporting continuous results, primary studies usually provide test performance at multiple but often different thresholds. This creates missing data when performing a meta‐analysis at each threshold. A standard meta‐analysis (no imputation [NI]) ignores such missing data. A single imputation (SI) approach was recently proposed to recover missing threshold results. Here, we propose a new method that performs multiple imputation of the missing threshold results using discrete combinations (MIDC). Methods The new MIDC method imputes missing threshold results by randomly selecting from the set of all possible discrete combinations which lie between the results for 2 known bounding thresholds. Imputed and observed results are then synthesised at each threshold. This is repeated multiple times, and the multiple pooled results at each threshold are combined using Rubin's rules to give final estimates. We compared the NI, SI, and MIDC approaches via simulation. Results Both imputation methods outperform the NI method in simulations. There was generally little difference in the SI and MIDC methods, but the latter was noticeably better in terms of estimating the between‐study variances and generally gave better coverage, due to slightly larger standard errors of pooled estimates. Given selective reporting of thresholds, the imputation methods also reduced bias in the summary receiver operating characteristic curve. Simulations demonstrate the imputation methods rely on an equal threshold spacing assumption. A real example is presented. Conclusions The SI and, in particular, MIDC methods can be used to examine the impact of missing threshold results in meta‐analysis of test accuracy studies. PMID:29052347
NASA Technical Reports Server (NTRS)
Kayten, Gerald G
1945-01-01
The analysis of results of wind-tunnel stability and control tests of powered airplane models in terms of the flying qualities of full-scale airplanes is advocated. In order to indicated the topics upon which comments are considered desirable in the report of a wind-tunnel stability and control investigation and to demonstrate the nature of the suggested analysis, the present NACA flying-qualities requirements are discussed in relation to wind-tunnel tests. General procedures for the estimation of flying qualities from wind-tunnel tests are outlined.
Thermoelastic analysis of solar cell arrays and their material properties
NASA Technical Reports Server (NTRS)
Salama, M. A.; Rowe, W. M.; Yasui, R. K.
1973-01-01
A thermoelastic stress analysis procedure is reported for predicting the thermally induced stresses and failures in silicon solar cell arrays. A prerequisite for the analysis is the characterization of the temperature-dependent thermal and mechanical properties of the solar cell materials. Extensive material property testing was carried out in the temperature range -200 to +200 C for the filter glass, P- and N-type silicon, interconnector metals, solder, and several candidate silicone rubber adhesives. The analysis procedure is applied to several solar cell array design configurations. Results of the analysis indicate the optimum design configuration, with respect to compatible materials, effect of the solder coating, and effect of the interconnector geometry. Good agreement was found between results of the analysis and the test program.
Bade, Richard; Tscharke, Benjamin J; Longo, Marie; Cooke, Richard; White, Jason M; Gerber, Cobus
2018-06-01
The societal impact of drug use is well known. An example is when drug-intoxicated drivers increase the burden on policing and healthcare services. This work presents the correlation of wastewater analysis (using UHPLC-MS/MS) and positive roadside drug testing results for methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and cannabis from December 2011-December 2016 in South Australia. Methamphetamine and MDMA showed similar trends between the data sources with matching increases and decreases, respectively. Cannabis was relatively steady based on wastewater analysis, but the roadside drug testing data started to diverge in the final part of the measurement period. The ability to triangulate data as shown here validates both wastewater analysis and roadside drug testing. This suggests that changes in overall population drug use revealed by WWA is consistent and proportional with changes in drug-driving behaviours. The results show that, at higher levels of drug use as measured by wastewater analysis, there is an increase in drug driving in the community and therefore more strain on health services and police. Copyright © 2018 Elsevier B.V. All rights reserved.
Benefits of a Low Severity Frontal Crash Test
Digges, Kennerly; Dalmotas, Dainius
2007-01-01
The US Federal Motor Vehicle Safety Standard for frontal protection requires vehicle crash tests into a rigid barrier with two belted dummies in the front seats. The standard was recently modified to require two separate 56 Kph frontal tests. In one test the dummies are 50% males. In the other test, the dummies are 5% females. Analysis of crash test data indicates that the 56 Kph test does not encourage technology to reduce chest injuries in lower severity crashes. Tests conducted by Transport Canada provide data from belted 5% female dummies in the front seats of vehicles that were subjected crashes into a rigid barrier at 40 Kph. An analysis of the results showed that for many vehicles, the risks of serious chest injuries were higher in the 40 Kph test than in a 56 Kph test. This paper examines the benefits that would result from a requirement for a low severity (40 Kph) frontal barrier crash test with two belted 5% female dummies and more stringent chest injury requirements. A preliminary benefits analysis for chest deflection allowable in the range of 28 mm. to 36 mm. was conducted. A standard that limits the chest deflection to 34 mm. would reduce serious chest injury by 16% to 24% for the belted population in frontal crashes. PMID:18184499
Benefits of a low severity frontal crash test.
Digges, Kennerly; Dalmotas, Dainius
2007-01-01
The US Federal Motor Vehicle Safety Standard for frontal protection requires vehicle crash tests into a rigid barrier with two belted dummies in the front seats. The standard was recently modified to require two separate 56 Kph frontal tests. In one test the dummies are 50% males. In the other test, the dummies are 5% females. Analysis of crash test data indicates that the 56 Kph test does not encourage technology to reduce chest injuries in lower severity crashes. Tests conducted by Transport Canada provide data from belted 5% female dummies in the front seats of vehicles that were subjected crashes into a rigid barrier at 40 Kph. An analysis of the results showed that for many vehicles, the risks of serious chest injuries were higher in the 40 Kph test than in a 56 Kph test. This paper examines the benefits that would result from a requirement for a low severity (40 Kph) frontal barrier crash test with two belted 5% female dummies and more stringent chest injury requirements. A preliminary benefits analysis for chest deflection allowable in the range of 28 mm. to 36 mm. was conducted. A standard that limits the chest deflection to 34 mm. would reduce serious chest injury by 16% to 24% for the belted population in frontal crashes.
Analysis and Test Correlation of Proof of Concept Box for Blended Wing Body-Low Speed Vehicle
NASA Technical Reports Server (NTRS)
Spellman, Regina L.
2003-01-01
The Low Speed Vehicle (LSV) is a 14.2% scale remotely piloted vehicle of the revolutionary Blended Wing Body concept. The design of the LSV includes an all composite airframe. Due to internal manufacturing capability restrictions, room temperature layups were necessary. An extensive materials testing and manufacturing process development effort was underwent to establish a process that would achieve the high modulus/low weight properties required to meet the design requirements. The analysis process involved a loads development effort that incorporated aero loads to determine internal forces that could be applied to a traditional FEM of the vehicle and to conduct detailed component analyses. A new tool, Hypersizer, was added to the design process to address various composite failure modes and to optimize the skin panel thickness of the upper and lower skins for the vehicle. The analysis required an iterative approach as material properties were continually changing. As a part of the material characterization effort, test articles, including a proof of concept wing box and a full-scale wing, were fabricated. The proof of concept box was fabricated based on very preliminary material studies and tested in bending, torsion, and shear. The box was then tested to failure under shear. The proof of concept box was also analyzed using Nastran and Hypersizer. The results of both analyses were scaled to determine the predicted failure load. The test results were compared to both the Nastran and Hypersizer analytical predictions. The actual failure occurred at 899 lbs. The failure was predicted at 1167 lbs based on the Nastran analysis. The Hypersizer analysis predicted a lower failure load of 960 lbs. The Nastran analysis alone was not sufficient to predict the failure load because it does not identify local composite failure modes. This analysis has traditionally been done using closed form solutions. Although Hypersizer is typically used as an optimizer for the design process, the failure prediction was used to help gain acceptance and confidence in this new tool. The correlated models and process were to be used to analyze the full BWB-LSV airframe design. The analysis and correlation with test results of the proof of concept box is presented here, including the comparison of the Nastran and Hypersizer results.
Evaluating the efficacy of a chemistry video game
NASA Astrophysics Data System (ADS)
Shapiro, Marina
A quasi-experimental design pre-test/post-test intervention study utilizing a within group analysis was conducted with 45 undergraduate college chemistry students that investigated the effect of implementing a game-based learning environment into an undergraduate college chemistry course in order to learn if serious educational games (SEGs) can be used to achieve knowledge gains of complex chemistry concepts and to achieve increase in students' positive attitude toward chemistry. To evaluate if students learn chemistry concepts by participating in a chemistry game-based learning environment, a one-way repeated measures analysis of variance (ANOVA) was conducted across three time points (pre-test, post-test, delayed post-test which were chemistry content exams). Results showed that there was an increase in exam scores over time. The results of the ANOVA indicated a statistically significant time effect. To evaluate if students' attitude towards chemistry increased as a result of participating in a chemistry game-based learning environment a paired samples t-test was conducted using a chemistry attitudinal survey by Mahdi (2014) as the pre- and post-test. Results of the paired-samples t-test indicated that there was no significant difference in pre-attitudinal scores and post-attitudinal scores.
Dynamic testing of a single-degree-of-freedom strapdown gyroscope
NASA Technical Reports Server (NTRS)
Lory, C. B.; Feldman, J.; Sinkiewicz, J. S., Jr.
1971-01-01
Test methods and results are presented for the equivalent average input rate of a single-degree-of-freedom gyroscope operated both open loop and with a ternary-logic pulse-torque-to-balance loop during multiaxis angular oscillation. For the open-loop tests, good agreement was obtained with theoretical results. Two-axis testing was performed for oscillations about the Input-Output axes, the Input-Spin axes, and the Spin-Output axes. These tests run in the torque-to-balance mode revealed significant departures from open-loop results in the induced drift rate. An analysis is developed explaining much of the closed-loop data presented. Test data for the gryoscope in a ternary torque-to-balance loop with constant input rates is presented. The tests demonstrate that the instrument rate linearity does not change with interrogation frequency from 3,600 to 14,400 Hz if the torque coil is tuned to offer a resistive load to the current switch. Analysis cited shows that gyroscope lag compensation eliminates multiple pulsing and other equivalent forms of degraded resolution in a wide variety of quantizing loops. This result is test verified for the ternary delta-modulator loop.
Medina-Rosas, Jorge; Yap, Kristy S; Anderson, Melanie; Su, Jiandong; Touma, Zahi
2016-09-01
To systematically review literature on the utility of spot urinary protein-creatinine ratio (PCR) as a screening test for proteinuria and its ability to accurately measure proteinuria compared with 24-hour urine collection (24H-P) in patients with systemic lupus erythematosus (SLE). We conducted a literature search (1900-2015) for articles comparing PCR and 24H-P in SLE patients in the databases Medline, Web of Science, and Embase. Included studies and their results were critically appraised and analyzed. Thirteen studies (1,001 patients; 84.01% women) were included. Ten studies reported on Pearson's correlation (range 0.67-0.94), and 3 studies reported on Spearman's correlation (range 0.78-1.00). The meta-analysis of studies with Pearson's correlation showed a high overall correlation of 0.80 between 24H-P and PCR, yet with high heterogeneity (I(2) = 97.2%). Correlation analysis is not sufficient to evaluate the utility of a new test against the gold standard test, and analysis on agreement is required. Seven studies reported on agreement: 3 studies analyzed concordance correlation coefficient (0.48-0.94), 3 analyzed intraclass correlation coefficient (0.66-0.95), and 1 analyzed kappa coefficient (0.58). These results confirmed that the agreement between 24H-P and PCR was inappropriate. Three studies included Bland-Altman plots, and the results also demonstrated poor agreement between both tests. The PCR has a utility as a screening test for proteinuria in SLE patients. The studies' results of 24H-P and PCR showed poor agreement between both tests, signifying that PCR should not be a substitute for the gold standard test (24H-P) to accurately measure proteinuria. © 2016, American College of Rheumatology.
NASA Astrophysics Data System (ADS)
Okajima, Kenji; Imai, Junichi; Tanaka, Tadatsugu; Iida, Toshiaki
Damage to piles in the liquefied ground is frequently reported. Buckling by the excess vertical load could be one of the causes of the pile damage, as well as the lateral flow of the ground and the lateral load at the pile head. The buckling mechanism is described as a complicated interaction between the pile deformation by the vertical load and the earth pressure change cased by the pile deformation. In this study, series of static buckling model tests of a pile were carried out in dried sand ground with various thickness of the layer. Finite element analysis was applied to the test results to verify the effectiveness of the elasto-plastic finite element analysis combining the implicit-explicit mixed type dynamic relaxation method with the return mapping method to the pile buckling problems. The test results and the analysis indicated the possibility that the buckling load of a pile decreases greatly where the thickness of the layer increases.
The analysis of energy consumption of the transport and manipulation process of Fanuc AM100iB robot
NASA Astrophysics Data System (ADS)
Cholewa, A.; Świder, J.; Zbilski, A.
2017-08-01
This article describes test results of energy consumption of Fanuc ArcMate 100iB robot during realization of the transport and manipulation process. The energy consumption test involved the acquisition of values of angular positions of the robot’s encoder shafts and values of tensions and expansions of the electrical currents in three phases of each engine. Based on the simulation results, the analysis of energy consumption was carried out, which specified the tested palletizing process using the set of complete and partial decompositions of the energy consumption of all these factors, which in significant degree impacted the amount of energy taken during the process. Quality of the data provided by the analysis of energy consumption was assessed through validation of results, which involved direct comparison of corresponding parameters, which values were measured and calculated. With regards to the developed analysis of energy consumption, computerized techniques were used to determine the impact of all material factors on the total energy consumption of the machine. The work presents the most significant results of the obtained outcomes.
Misleading biochemical laboratory test results
Nanji, Amin A.
1984-01-01
This article reviews the general and specific factors that interfere with the performance of common biochemical laboratory tests and the interpretation of their results. The clinical status of the patient, drug interactions, and in-vivo and in-vitro biochemical interactions and changes may alter the results obtained from biochemical analysis of blood constituents. Failure to recognize invalid laboratory test results may lead to injudicious and dangerous management of patients. PMID:6375845
Annotation analysis for testing drug safety signals using unstructured clinical notes
2012-01-01
Background The electronic surveillance for adverse drug events is largely based upon the analysis of coded data from reporting systems. Yet, the vast majority of electronic health data lies embedded within the free text of clinical notes and is not gathered into centralized repositories. With the increasing access to large volumes of electronic medical data—in particular the clinical notes—it may be possible to computationally encode and to test drug safety signals in an active manner. Results We describe the application of simple annotation tools on clinical text and the mining of the resulting annotations to compute the risk of getting a myocardial infarction for patients with rheumatoid arthritis that take Vioxx. Our analysis clearly reveals elevated risks for myocardial infarction in rheumatoid arthritis patients taking Vioxx (odds ratio 2.06) before 2005. Conclusions Our results show that it is possible to apply annotation analysis methods for testing hypotheses about drug safety using electronic medical records. PMID:22541596
Verification of combined thermal-hydraulic and heat conduction analysis code FLOWNET/TRUMP
NASA Astrophysics Data System (ADS)
Maruyama, Soh; Fujimoto, Nozomu; Kiso, Yoshihiro; Murakami, Tomoyuki; Sudo, Yukio
1988-09-01
This report presents the verification results of the combined thermal-hydraulic and heat conduction analysis code, FLOWNET/TRUMP which has been utilized for the core thermal hydraulic design, especially for the analysis of flow distribution among fuel block coolant channels, the determination of thermal boundary conditions for fuel block stress analysis and the estimation of fuel temperature in the case of fuel block coolant channel blockage accident in the design of the High Temperature Engineering Test Reactor(HTTR), which the Japan Atomic Energy Research Institute has been planning to construct in order to establish basic technologies for future advanced very high temperature gas-cooled reactors and to be served as an irradiation test reactor for promotion of innovative high temperature new frontier technologies. The verification of the code was done through the comparison between the analytical results and experimental results of the Helium Engineering Demonstration Loop Multi-channel Test Section(HENDEL T(sub 1-M)) with simulated fuel rods and fuel blocks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
In this report, the scope of the tests, the method of analysis, the results, and the conclusions are discussed. The first test indicated that the requirements generated by the Standard procedures and formulae appear to yield reasonable results, although some of the cost data provided as defaults in the Standard should be reevaluated. The second test provided experience that was useful in modifying the points compliance format, but did not uncover any procedural issues that would lead to unreasonable results. These conclusions are based on analysis using the Automated Residential Energy Standard (ARES) computer program, developed to simplify the processmore » of standards generation.« less
Grant, Andrew; Grant, Gwyneth; Gagné, Jean; Blanchette, Carl; Comeau, Émilie; Brodeur, Guillaume; Dionne, Jonathon; Ayite, Alphonse; Synak, Piotr; Wroblewski, Jakub; Apanowitz, Cas
2001-01-01
The patient centred electronic patient record enables retrospective analysis of practice patterns as one means to assist clinicians adjust and improve their practice. An interrogation of the data-warehouse linking test use to Diagnostic Related Group (DRG) of one years data of the Sherbrooke University Hospital showed that one-third of patients used two-thirds of these diagnostic tests. Using RoughSets analysis, zones of repeated tests were demonstrated where results remained within stable limits. It was concluded that 30% of fluid and electrolyte testing was probably unnecessary. These findings led to an endorsement of changing the test request formats in the hospital information system from profiles to individual tests requiring justification.
Simulation Analysis of Helicopter Ground Resonance Nonlinear Dynamics
NASA Astrophysics Data System (ADS)
Zhu, Yan; Lu, Yu-hui; Ling, Ai-min
2017-07-01
In order to accurately predict the dynamic instability of helicopter ground resonance, a modeling and simulation method of helicopter ground resonance considering nonlinear dynamic characteristics of components (rotor lead-lag damper, landing gear wheel and absorber) is presented. The numerical integral method is used to calculate the transient responses of the body and rotor, simulating some disturbance. To obtain quantitative instabilities, Fast Fourier Transform (FFT) is conducted to estimate the modal frequencies, and the mobile rectangular window method is employed in the predictions of the modal damping in terms of the response time history. Simulation results show that ground resonance simulation test can exactly lead up the blade lead-lag regressing mode frequency, and the modal damping obtained according to attenuation curves are close to the test results. The simulation test results are in accordance with the actual accident situation, and prove the correctness of the simulation method. This analysis method used for ground resonance simulation test can give out the results according with real helicopter engineering tests.
Søreide, Kjetil; Kørner, Hartwig; Søreide, Jon Arne
2011-01-01
In surgical research, the ability to correctly classify one type of condition or specific outcome from another is of great importance for variables influencing clinical decision making. Receiver-operating characteristic (ROC) curve analysis is a useful tool in assessing the diagnostic accuracy of any variable with a continuous spectrum of results. In order to rule a disease state in or out with a given test, the test results are usually binary, with arbitrarily chosen cut-offs for defining disease versus health, or for grading of disease severity. In the postgenomic era, the translation from bench-to-bedside of biomarkers in various tissues and body fluids requires appropriate tools for analysis. In contrast to predetermining a cut-off value to define disease, the advantages of applying ROC analysis include the ability to test diagnostic accuracy across the entire range of variable scores and test outcomes. In addition, ROC analysis can easily examine visual and statistical comparisons across tests or scores. ROC is also favored because it is thought to be independent from the prevalence of the condition under investigation. ROC analysis is used in various surgical settings and across disciplines, including cancer research, biomarker assessment, imaging evaluation, and assessment of risk scores.With appropriate use, ROC curves may help identify the most appropriate cutoff value for clinical and surgical decision making and avoid confounding effects seen with subjective ratings. ROC curve results should always be put in perspective, because a good classifier does not guarantee the expected clinical outcome. In this review, we discuss the fundamental roles, suggested presentation, potential biases, and interpretation of ROC analysis in surgical research.
Detecting Non-Gaussian and Lognormal Characteristics of Temperature and Water Vapor Mixing Ratio
NASA Astrophysics Data System (ADS)
Kliewer, A.; Fletcher, S. J.; Jones, A. S.; Forsythe, J. M.
2017-12-01
Many operational data assimilation and retrieval systems assume that the errors and variables come from a Gaussian distribution. This study builds upon previous results that shows that positive definite variables, specifically water vapor mixing ratio and temperature, can follow a non-Gaussian distribution and moreover a lognormal distribution. Previously, statistical testing procedures which included the Jarque-Bera test, the Shapiro-Wilk test, the Chi-squared goodness-of-fit test, and a composite test which incorporated the results of the former tests were employed to determine locations and time spans where atmospheric variables assume a non-Gaussian distribution. These tests are now investigated in a "sliding window" fashion in order to extend the testing procedure to near real-time. The analyzed 1-degree resolution data comes from the National Oceanic and Atmospheric Administration (NOAA) Global Forecast System (GFS) six hour forecast from the 0Z analysis. These results indicate the necessity of a Data Assimilation (DA) system to be able to properly use the lognormally-distributed variables in an appropriate Bayesian analysis that does not assume the variables are Gaussian.
Development of an integrated aeroservoelastic analysis program and correlation with test data
NASA Technical Reports Server (NTRS)
Gupta, K. K.; Brenner, M. J.; Voelker, L. S.
1991-01-01
The details and results are presented of the general-purpose finite element STructural Analysis RoutineS (STARS) to perform a complete linear aeroelastic and aeroservoelastic analysis. The earlier version of the STARS computer program enabled effective finite element modeling as well as static, vibration, buckling, and dynamic response of damped and undamped systems, including those with pre-stressed and spinning structures. Additions to the STARS program include aeroelastic modeling for flutter and divergence solutions, and hybrid control system augmentation for aeroservoelastic analysis. Numerical results of the X-29A aircraft pertaining to vibration, flutter-divergence, and open- and closed-loop aeroservoelastic controls analysis are compared to ground vibration, wind-tunnel, and flight-test results. The open- and closed-loop aeroservoelastic control analyses are based on a hybrid formulation representing the interaction of structural, aerodynamic, and flight-control dynamics.
Automatic analysis of the micronucleus test in primary human lymphocytes using image analysis.
Frieauff, W; Martus, H J; Suter, W; Elhajouji, A
2013-01-01
The in vitro micronucleus test (MNT) is a well-established test for early screening of new chemical entities in industrial toxicology. For assessing the clastogenic or aneugenic potential of a test compound, micronucleus induction in cells has been shown repeatedly to be a sensitive and a specific parameter. Various automated systems to replace the tedious and time-consuming visual slide analysis procedure as well as flow cytometric approaches have been discussed. The ROBIAS (Robotic Image Analysis System) for both automatic cytotoxicity assessment and micronucleus detection in human lymphocytes was developed at Novartis where the assay has been used to validate positive results obtained in the MNT in TK6 cells, which serves as the primary screening system for genotoxicity profiling in early drug development. In addition, the in vitro MNT has become an accepted alternative to support clinical studies and will be used for regulatory purposes as well. The comparison of visual with automatic analysis results showed a high degree of concordance for 25 independent experiments conducted for the profiling of 12 compounds. For concentration series of cyclophosphamide and carbendazim, a very good correlation between automatic and visual analysis by two examiners could be established, both for the relative division index used as cytotoxicity parameter, as well as for micronuclei scoring in mono- and binucleated cells. Generally, false-positive micronucleus decisions could be controlled by fast and simple relocation of the automatically detected patterns. The possibility to analyse 24 slides within 65h by automatic analysis over the weekend and the high reproducibility of the results make automatic image processing a powerful tool for the micronucleus analysis in primary human lymphocytes. The automated slide analysis for the MNT in human lymphocytes complements the portfolio of image analysis applications on ROBIAS which is supporting various assays at Novartis.
Advanced composite vertical stabilizer for DC-10 transport aircraft
NASA Technical Reports Server (NTRS)
Stephens, C. O.
1978-01-01
The structural design configuration for the Composite Vertical Stabilizer is described and the structural design, analysis, and weight activities are presented. The status of fabrication and test activities for the development test portion of the program is described. Test results are presented for the skin panels, spar web, spar cap to cover, and laminate properties specimens. Engineering drawings of vertification test panels and root fittings, rudder support specimens, titanium fittings, and rear spar specimen analysis models are included.
NASA Technical Reports Server (NTRS)
Parrish, R. V.; Mckissick, B. T.; Steinmetz, G. G.
1979-01-01
A recent modification of the methodology of profile analysis, which allows the testing for differences between two functions as a whole with a single test, rather than point by point with multiple tests is discussed. The modification is applied to the examination of the issue of motion/no motion conditions as shown by the lateral deviation curve as a function of engine cut speed of a piloted 737-100 simulator. The results of this application are presented along with those of more conventional statistical test procedures on the same simulator data.
System identification of the JPL micro-precision interferometer truss - Test-analysis reconciliation
NASA Technical Reports Server (NTRS)
Red-Horse, J. R.; Marek, E. L.; Levine-West, M.
1993-01-01
The JPL Micro-Precision Interferometer (MPI) is a testbed for studying the use of control-structure interaction technology in the design of space-based interferometers. A layered control architecture will be employed to regulate the interferometer optical system to tolerances in the nanometer range. An important aspect of designing and implementing the control schemes for such a system is the need for high fidelity, test-verified analytical structural models. This paper focuses on one aspect of the effort to produce such a model for the MPI structure, test-analysis model reconciliation. Pretest analysis, modal testing, and model refinement results are summarized for a series of tests at both the component and full system levels.
ERIC Educational Resources Information Center
Leaper, Campbell; Robnett, Rachael D.
2011-01-01
Robin Lakoff proposed that women are more likely than men to use tentative speech forms (e.g., hedges, qualifiers/disclaimers, tag questions, intensifiers). Based on conflicting results from research testing Lakoff's claims, a meta-analysis of studies testing gender differences in tentative language was conducted. The sample included 29 studies…
Breast-feeding and postpartum weight retention: a systematic review and meta-analysis.
He, Xiujie; Zhu, Meng; Hu, Chuanlai; Tao, Xingyong; Li, Yingchun; Wang, Qiuwei; Liu, Yue
2015-12-01
Weight gained during pregnancy and postpartum weight retention might contribute to obesity in women of childbearing age. Whether breast-feeding (BF) may decrease postpartum weight retention (PPWR) is still controversial. The purpose of our systematic review and meta-analysis was to investigate the relationship between BF and PPWR. Three databases were systematically reviewed and the reference lists of relevant articles were checked. Meta-analysis was performed to quantify the pooled standardized mean differences (SMD) of BF on PPWR by using a random-effect model. Heterogeneity was tested using the χ 2 test and I 2 statistics. Publication bias was estimated from Egger's test (linear regression method) or Begg's test (rank correlation method). Among 349 search hits, eleven studies met the inclusion criteria for the meta-analysis. Seven studies were conducted in the USA, one in Brazil, one in France, one in Georgia and one in Croatia. Compared with formula-feeding, BF for 3 to ≤6 months seemed to have a negative influence on PPWR and if BF continued for >6 months had little or no influence on PPWR. In a subgroup meta-analysis, the results did not change substantially after the analysis had been classified by available confounding factors. There was no indication of a publication bias from the result of either Egger's test or Begg's test. Although the available evidence held belief that BF decreases PPWR, more robust studies are needed to reliably assess the impact of patterns and duration of BF on PPWR.
Design/analysis of the JWST ISIM bonded joints for survivability at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Bartoszyk, Andrew; Johnston, John; Kaprielian, Charles; Kuhn, Jonathan; Kunt, Cengiz; Rodini, Benjamin; Young, Daniel
2005-08-01
A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite adhesively bonded joints at the cryogenic temperature of 30K (-405°F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to hybrid composite tubes (75mm square) made with M55J/954-6 and T300/954-6 prepregs. Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently, the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.
1992-10-01
N=8) and Results of 44 Statistical Analyses for Impact Test Performed on Forefoot of Unworn Footwear A-2. Summary Statistics (N=8) and Results of...on Forefoot of Worn Footwear Vlll Tables (continued) Table Page B-2. Summary Statistics (N=4) and Results of 76 Statistical Analyses for Impact...used tests to assess heel and forefoot shock absorption, upper and sole durability, and flexibility (Cavanagh, 1978). Later, the number of tests was
NASA Technical Reports Server (NTRS)
Keegan, W. B.
1974-01-01
In order to produce cost effective environmental test programs, the test specifications must be realistic and to be useful, they must be available early in the life of a program. This paper describes a method for achieving such specifications for subsystems by utilizing the results of a statistical analysis of data acquired at subsystem mounting locations during system level environmental tests. The paper describes the details of this statistical analysis. The resultant recommended levels are a function of the subsystems' mounting location in the spacecraft. Methods of determining this mounting 'zone' are described. Recommendations are then made as to which of the various problem areas encountered should be pursued further.
Smith, C W; Snyder, D R; Handelsman, M M
1982-02-01
The present study investigated the hypothesis that psychological symptoms may serve a self-protective function by providing an alternative explanation for potential failure in evaluating situations. It was hypothesized that highly test-anxious subjects would report anxiety symptoms in a pattern that reflected strategic presentation of symptoms; more specifically, it was predicted that greater reported anxiety should result when anxiety was a viable explanation for poor performance on an intelligence test and that lower reported anxiety should result when anxiety was not a viable explanation for poor performance. Analysis of state measures of self-reported anxiety supported these predictions. Further analysis indicated that when anxiety was not a viable explanation for poor test performance, high test-anxiety subjects reported reduced effort as an alternative self-protective strategy. These results are discussed in terms of traditional models of symptoms as self-protective strategies, current social psychological models of symptoms, and in reference to recent theory and research about the nature and treatment of test anxiety.
The Statistical Analysis Techniques to Support the NGNP Fuel Performance Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bihn T. Pham; Jeffrey J. Einerson
2010-06-01
This paper describes the development and application of statistical analysis techniques to support the AGR experimental program on NGNP fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel/graphite temperature) is regulated by the He-Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the SAS-based NGNP Data Management and Analysis System (NDMAS) for automatedmore » processing and qualification of the AGR measured data. The NDMAS also stores daily neutronic (power) and thermal (heat transfer) code simulation results along with the measurement data, allowing for their combined use and comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the target quantity (fuel temperature) within a given range.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
Rath, S; Panda, M; Sahu, M C; Padhy, R N
2015-09-01
Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation-time of flight mass spectrometry or fluorescence in situ hybridization or enzyme-linked immunosorbent assay [ELISA] or restriction fragment length polymorphism or DNA/RNA probes of known fungal taxa) in advanced laboratories. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Validation of an Active Gear, Flexible Aircraft Take-off and Landing analysis (AGFATL)
NASA Technical Reports Server (NTRS)
Mcgehee, J. R.
1984-01-01
The results of an analytical investigation using a computer program for active gear, flexible aircraft take off and landing analysis (AGFATL) are compared with experimental data from shaker tests, drop tests, and simulated landing tests to validate the AGFATL computer program. Comparison of experimental and analytical responses for both passive and active gears indicates good agreement for shaker tests and drop tests. For the simulated landing tests, the passive and active gears were influenced by large strut binding friction forces. The inclusion of these undefined forces in the analytical simulations was difficult, and consequently only fair to good agreement was obtained. An assessment of the results from the investigation indicates that the AGFATL computer program is a valid tool for the study and initial design of series hydraulic active control landing gear systems.
Automotive Stirling Engine Development Program
NASA Technical Reports Server (NTRS)
Nightingale, N.; Ernst, W.; Richey, A.; Simetkosky, M.; Smith, G.; Antonelli, M. (Editor)
1983-01-01
Mod I engine testing and test results, the test of a Mod I engine in the United States, Mod I engine characterization and analysis, Mod I Transient Test Bed fuel economy, Mod I-A engine performance are discussed. Stirling engine reference engine manufacturing and reduced size studies, components and subsystems, and the study and test of low-cost casting alloys are also covered. The overall program philosophy is outlined, and data and results are presented.
J.N. King; M.J. Carson; G.R. Johnson
1998-01-01
Genetic parameters from a second generation (F2) disconnected diallel progeny test of the New Zealand radiata pine improvement programme are presented. Heritability estimates of growth and yield traits of 0.2 are similar to progeny test results of the previous generation (F1) generation tests. A trend of declining dominance...
Sims Prototype System 2 test results: Engineering analysis
NASA Technical Reports Server (NTRS)
1978-01-01
The testing, problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype System, 2, solar hot water system, at the Marshall Space Flight Center Solar Test Facility was described. System 2 is a liquid, non draining solar energy system for supplying domestic hot water to single residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.
Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Chang Jae; Han, Seung; Yun, Jae Hee
2015-07-01
Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determinationmore » methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holenemser, K.H.
1995-10-01
This report surveys the analysis and tests performed at Washington University in St. Louis, Missouri, on a horizontal-axis, two-laded wind turbine with teeter hub. The introduction is a brief account of results obtained during the 5-year period ending December 1985. The wind tunnel model and the test turbine (7.6 m [25 ft.] in diameter) at Washington University`s Tyson Research Center had a 67{degree} delta-three angle of the teeter axis. The introduction explains why this configuration was selected and named the passive cycle pitch (PCP) wind turbine. Through the analysis was not limited to the PCP rotor, all tests, including thosemore » done from 1986 to 1994, wee conducted with the same teetered wind rotor. The blades are rather stiff and have only a small elastic coning angle and no precone.« less
NASA Astrophysics Data System (ADS)
Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey
2018-05-01
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.
NASA Technical Reports Server (NTRS)
Martellucci, A.; Maguire, B. L.; Neff, R. S.
1972-01-01
The objective of the study was to provide a detailed post flight evaluation of ballistic vehicle flight test boundary layer transition data. A total of fifty-five vehicles were selected for analysis. These vehicles were chosen from a data sampling of roughly two hundred flights and the criteria for vehicle selection is delineated herein. The results of the analysis indicate that frustum transition of re-entry vehicles appears to be nose tip dominated. Frustum related parameters and materials apparently have a second order effect on transition. This implies that local viscous parameters on the frustum should not correlate flight test transition data, and in fact they do not. Specific parameters relative to the nose tip have been identified as the apparent dominant factors that characterize the transition phenomena and a correlation of flight test data is presented.
Modeling and dynamic environment analysis technology for spacecraft
NASA Astrophysics Data System (ADS)
Fang, Ren; Zhaohong, Qin; Zhong, Zhang; Zhenhao, Liu; Kai, Yuan; Long, Wei
Spacecraft sustains complex and severe vibrations and acoustic environments during flight. Predicting the resulting structures, including numerical predictions of fluctuating pressure, updating models and random vibration and acoustic analysis, plays an important role during the design, manufacture and ground testing of spacecraft. In this paper, Monotony Integrative Large Eddy Simulation (MILES) is introduced to predict the fluctuating pressure of the fairing. The exact flow structures of the fairing wall surface under different Mach numbers are obtained, then a spacecraft model is constructed using the finite element method (FEM). According to the modal test data, the model is updated by the penalty method. On this basis, the random vibration and acoustic responses of the fairing and satellite are analyzed by different methods. The simulated results agree well with the experimental ones, which shows the validity of the modeling and dynamic environment analysis technology. This information can better support test planning, defining test conditions and designing optimal structures.
ERIC Educational Resources Information Center
Keith, Timothy Z.; Kranzler, John H.; Flanagan, Dawn P.
2001-01-01
Reports the results of the first joint confirmatory factor analysis (CFA) of the Cognitive Assessment System (CAS) and the Woodcock-Johnson Tests of Cognitive Abilities-3rd Edition (WJ III). Results of these analyses do not support the construct validity of the CAS as a measure of the PASS (planning, attention, simultaneous, and sequential)…
Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria
Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.
2013-01-01
Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403
SIRTF primary mirror design, analysis, and testing
NASA Technical Reports Server (NTRS)
Sarver, George L., III; Maa, Scott; Chang, LI
1990-01-01
The primary mirror assembly (PMA) requirements and concepts for the Space Infrared Telescope Facility (SIRTF) program are discussed. The PMA studies at NASA/ARC resulted in the design of two engineering test articles, the development of a mirror mount cryogenic static load testing system, and the procurement and partial testing of a full scale spherical mirror mounting system. Preliminary analysis and testing of the single arch mirror with conical mount design and the structured mirror with the spherical mount design indicate that the designs will meet all figure and environmental requirements of the SIRTF program.
Hallock, M L; Alper, S J; Karsh, B
The diagnosis of illness is important for quality patient care and patient safety and is greatly aided by diagnostic testing. For diagnostic tests, such as pathology and radiology, to positively impact patient care, the tests must be processed and the physician and patient must be notified of the results in a timely fashion. There are many steps in the diagnostic testing process, from ordering to result dissemination, where the process can break down and therefore delay patient care and reduce patient safety. This study was carried out to examine the diagnostic testing process (i.e. from ordering to result notification) and used a macro-ergonomic work system analysis to uncover system design flaws that contributed to delayed physician and patient notification of results. The study was carried out in a large urban outpatient health-care facility made up of 30 outpatient clinics. Results indicated a number of variances that contributed to delays, the majority of which occurred across the boundaries of different systems and were related to poor or absent feedback structures. Recommendations for improvements are discussed.
NASA Astrophysics Data System (ADS)
Yang, Thomas; Shen, Yang; Zhang, Yifan; Sweis, Jason; Lai, Ya-Chieh
2017-03-01
Silicon testing results are regularly collected for a particular lot of wafers to study yield loss from test result diagnostics. Product engineers will analyze the diagnostic results and perform a number of physical failure analyses to detect systematic defects which cause yield loss for these sets of wafers in order to feedback the information to process engineers for process improvements. Most of time, the systematic defects that are detected are major issues or just one of the causes for the overall yield loss. This paper will present a working flow for using design analysis techniques combined with diagnostic methods to systematically transform silicon testing information into physical layout information. A new set of the testing results are received from a new lot of wafers for the same product. We can then correlate all the diagnostic results from different periods of time to check which blocks or nets have been highlighted or stop occurring on the failure reports in order to monitor process changes which impact the yield. The design characteristic analysis flow is also implemented to find 1) the block connections on a design that have failed electrical test or 2) frequently used cells that been highlighted multiple times.
MetaGenyo: a web tool for meta-analysis of genetic association studies.
Martorell-Marugan, Jordi; Toro-Dominguez, Daniel; Alarcon-Riquelme, Marta E; Carmona-Saez, Pedro
2017-12-16
Genetic association studies (GAS) aims to evaluate the association between genetic variants and phenotypes. In the last few years, the number of this type of study has increased exponentially, but the results are not always reproducible due to experimental designs, low sample sizes and other methodological errors. In this field, meta-analysis techniques are becoming very popular tools to combine results across studies to increase statistical power and to resolve discrepancies in genetic association studies. A meta-analysis summarizes research findings, increases statistical power and enables the identification of genuine associations between genotypes and phenotypes. Meta-analysis techniques are increasingly used in GAS, but it is also increasing the amount of published meta-analysis containing different errors. Although there are several software packages that implement meta-analysis, none of them are specifically designed for genetic association studies and in most cases their use requires advanced programming or scripting expertise. We have developed MetaGenyo, a web tool for meta-analysis in GAS. MetaGenyo implements a complete and comprehensive workflow that can be executed in an easy-to-use environment without programming knowledge. MetaGenyo has been developed to guide users through the main steps of a GAS meta-analysis, covering Hardy-Weinberg test, statistical association for different genetic models, analysis of heterogeneity, testing for publication bias, subgroup analysis and robustness testing of the results. MetaGenyo is a useful tool to conduct comprehensive genetic association meta-analysis. The application is freely available at http://bioinfo.genyo.es/metagenyo/ .
Google glass based immunochromatographic diagnostic test analysis
NASA Astrophysics Data System (ADS)
Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan
2015-03-01
Integration of optical imagers and sensors into recently emerging wearable computational devices allows for simpler and more intuitive methods of integrating biomedical imaging and medical diagnostics tasks into existing infrastructures. Here we demonstrate the ability of one such device, the Google Glass, to perform qualitative and quantitative analysis of immunochromatographic rapid diagnostic tests (RDTs) using a voice-commandable hands-free software-only interface, as an alternative to larger and more bulky desktop or handheld units. Using the built-in camera of Glass to image one or more RDTs (labeled with Quick Response (QR) codes), our Glass software application uploads the captured image and related information (e.g., user name, GPS, etc.) to our servers for remote analysis and storage. After digital analysis of the RDT images, the results are transmitted back to the originating Glass device, and made available through a website in geospatial and tabular representations. We tested this system on qualitative human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) RDTs. For qualitative HIV tests, we demonstrate successful detection and labeling (i.e., yes/no decisions) for up to 6-fold dilution of HIV samples. For quantitative measurements, we activated and imaged PSA concentrations ranging from 0 to 200 ng/mL and generated calibration curves relating the RDT line intensity values to PSA concentration. By providing automated digitization of both qualitative and quantitative test results, this wearable colorimetric diagnostic test reader platform on Google Glass can reduce operator errors caused by poor training, provide real-time spatiotemporal mapping of test results, and assist with remote monitoring of various biomedical conditions.
CADDIS Volume 4. Data Analysis: Basic Analyses
Use of statistical tests to determine if an observation is outside the normal range of expected values. Details of CART, regression analysis, use of quantile regression analysis, CART in causal analysis, simplifying or pruning resulting trees.
The Range Safety Debris Catalog Analysis in Preparation for the Pad Abort One Flight Test
NASA Technical Reports Server (NTRS)
Kutty, Prasad M.; Pratt, William D.
2010-01-01
The Pad Abort One flight test of the Orion Abort Flight Test Program is currently under development with the goal of demonstrating the capability of the Launch Abort System. In the event of a launch failure, this system will propel the Crew Exploration Vehicle to safety. An essential component of this flight test is range safety, which ensures the security of range assets and personnel. A debris catalog analysis was done as part of a range safety data package delivered to the White Sands Missile Range in New Mexico where the test will be conducted. The analysis discusses the consequences of an overpressurization of the Abort Motor. The resulting structural failure was assumed to create a debris field of vehicle fragments that could potentially pose a hazard to the range. A statistical model was used to assemble the debris catalog of potential propellant fragments. Then, a thermodynamic, energy balance model was applied to the system in order to determine the imparted velocity to these propellant fragments. This analysis was conducted at four points along the flight trajectory to better understand the failure consequences over the entire flight. The methods used to perform this analysis are outlined in detail and the corresponding results are presented and discussed.
The Relevance of Visual Sequential Memory to Reading.
ERIC Educational Resources Information Center
Crispin, Lisa; And Others
1984-01-01
Results of three visual sequential memory tests and a group reading test given to 19 elementary students are discussed in terms of task analysis and structuralist approaches to analysis of reading skills. Relation of visual sequential memory to other reading subskills is considered in light of current reasearch. (CMG)
RANDOMIZATION PROCEDURES FOR THE ANALYSIS OF EDUCATIONAL EXPERIMENTS.
ERIC Educational Resources Information Center
COLLIER, RAYMOND O.
CERTAIN SPECIFIC ASPECTS OF HYPOTHESIS TESTS USED FOR ANALYSIS OF RESULTS IN RANDOMIZED EXPERIMENTS WERE STUDIED--(1) THE DEVELOPMENT OF THE THEORETICAL FACTOR, THAT OF PROVIDING INFORMATION ON STATISTICAL TESTS FOR CERTAIN EXPERIMENTAL DESIGNS AND (2) THE DEVELOPMENT OF THE APPLIED ELEMENT, THAT OF SUPPLYING THE EXPERIMENTER WITH MACHINERY FOR…
SU-G-BRB-02: An Open-Source Software Analysis Library for Linear Accelerator Quality Assurance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerns, J; Yaldo, D
Purpose: Routine linac quality assurance (QA) tests have become complex enough to require automation of most test analyses. A new data analysis software library was built that allows physicists to automate routine linear accelerator quality assurance tests. The package is open source, code tested, and benchmarked. Methods: Images and data were generated on a TrueBeam linac for the following routine QA tests: VMAT, starshot, CBCT, machine logs, Winston Lutz, and picket fence. The analysis library was built using the general programming language Python. Each test was analyzed with the library algorithms and compared to manual measurements taken at the timemore » of acquisition. Results: VMAT QA results agreed within 0.1% between the library and manual measurements. Machine logs (dynalogs & trajectory logs) were successfully parsed; mechanical axis positions were verified for accuracy and MLC fluence agreed well with EPID measurements. CBCT QA measurements were within 10 HU and 0.2mm where applicable. Winston Lutz isocenter size measurements were within 0.2mm of TrueBeam’s Machine Performance Check. Starshot analysis was within 0.2mm of the Winston Lutz results for the same conditions. Picket fence images with and without a known error showed that the library was capable of detecting MLC offsets within 0.02mm. Conclusion: A new routine QA software library has been benchmarked and is available for use by the community. The library is open-source and extensible for use in larger systems.« less
2005-05-01
RESULTS ................................................................................................................49 5.3.1 Phase I Test Data...Ins 3 2.2a Wrinkling failure test article 7 2.2b Test results for a) Set A “0° core”, and b) Set B “90° core” 7 2.2c Test ... results for c) Set E “Isotropic (Foam) Core” 8 2.3 P = T because test data not yet reanalyzed with established CFs 9 2.4 P and T are now different
NASA Astrophysics Data System (ADS)
Jokhio, Gul A.; Syed Mohsin, Sharifah M.; Gul, Yasmeen
2018-04-01
It has been established that Adobe provides, in addition to being sustainable and economic, a better indoor air quality without spending extensive amounts of energy as opposed to the modern synthetic materials. The material, however, suffers from weak structural behaviour when subjected to adverse loading conditions. A wide range of mechanical properties has been reported in literature owing to lack of research and standardization. The present paper presents the statistical analysis of the results that were obtained through compressive and flexural tests on Adobe samples. Adobe specimens with and without wire mesh reinforcement were tested and the results were reported. The statistical analysis of these results presents an interesting read. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. This increase is statistically significant. The flexural response of Adobe has also shown improvement with the addition of wire mesh reinforcement, however, the statistical significance of the same cannot be established.
Chaves, Sandra; Gadanho, Mário; Tenreiro, Rogério; Cabrita, José
1999-01-01
Metronidazole susceptibility of 100 Helicobacter pylori strains was assessed by determining the inhibition zone diameters by disk diffusion test and the MICs by agar dilution and PDM Epsilometer test (E test). Linear regression analysis was performed, allowing the definition of significant linear relations, and revealed correlations of disk diffusion results with both E-test and agar dilution results (r2 = 0.88 and 0.81, respectively). No significant differences (P = 0.84) were found between MICs defined by E test and those defined by agar dilution, taken as a standard. Reproducibility comparison between E-test and disk diffusion tests showed that they are equivalent and with good precision. Two interpretative susceptibility schemes (with or without an intermediate class) were compared by an interpretative error rate analysis method. The susceptibility classification scheme that included the intermediate category was retained, and breakpoints were assessed for diffusion assay with 5-μg metronidazole disks. Strains with inhibition zone diameters less than 16 mm were defined as resistant (MIC > 8 μg/ml), those with zone diameters equal to or greater than 16 mm but less than 21 mm were considered intermediate (4 μg/ml < MIC ≤ 8 μg/ml), and those with zone diameters of 21 mm or greater were regarded as susceptible (MIC ≤ 4 μg/ml). Error rate analysis applied to this classification scheme showed occurrence frequencies of 1% for major errors and 7% for minor errors, when the results were compared to those obtained by agar dilution. No very major errors were detected, suggesting that disk diffusion might be a good alternative for determining the metronidazole sensitivity of H. pylori strains. PMID:10203543
Mechergui, Arij; Achour, Wafa; Ben Hassen, Assia
2014-08-01
We aimed to compare accuracy of genus and species level identification of Neisseria spp. using biochemical testing and 16S rRNA sequence analysis. These methods were evaluated using 85 Neisseria spp. clinical isolates initially identified to the genus level by conventional biochemical tests and API NH system (Bio-Mérieux(®)). In 34 % (29/85), more than one possibility was given by 16S rRNA sequence analysis. In 6 % (5/85), one of the possibilities offered by 16S rRNA gene sequencing, agreed with the result given by biochemical testing. In 4 % (3/85), the same species was given by both methods. 16S rRNA gene sequencing results did not correlate well with biochemical tests.
NASA Technical Reports Server (NTRS)
1973-01-01
The results of a study to define criteria and techniques of design, analysis and test which permit the use of a single major structural test article for performing dynamic, fatigue, and static testing are presented. The criteria developed is applicable to both space vehicles and aircraft structures operating in the subsonic or supersonic regime. The feasibility of such an approach was demonstrated by defining test interactions, compatibilities and incompatibilities between the three different types of tests. The results of the study indicate that the single test article concept is feasible with a testing sequence of dynamic test followed by a fatigue and static test.
Analysis of subsonic wind tunnel with variation shape rectangular and octagonal on test section
NASA Astrophysics Data System (ADS)
Rhakasywi, D.; Ismail; Suwandi, A.; Fadhli, A.
2018-02-01
The need for good design in the aerodynamics field required a wind tunnel design. The wind tunnel design required in this case is capable of generating laminar flow. In this research searched for wind tunnel models with rectangular and octagonal variations with objectives to generate laminar flow in the test section. The research method used numerical approach of CFD (Computational Fluid Dynamics) and manual analysis to analyze internal flow in test section. By CFD simulation results and manual analysis to generate laminar flow in the test section is a design that has an octagonal shape without filled for optimal design.
NASA Technical Reports Server (NTRS)
Johnson, W. S. (Editor)
1989-01-01
The present conference discusses the tension and compression testing of MMCs, the measurement of advanced composites' thermal expansion, plasticity theory for fiber-reinforced composites, a deformation analysis of boron/aluminum specimens by moire interferometry, strength prediction methods for MMCs, and the analysis of notched MMCs under tensile loading. Also discussed are techniques for the mechanical and thermal testing of Ti3Al/SCS-6 MMCs, damage initiation and growth in fiber-reinforced MMCs, the shear testing of MMCs, the crack growth and fracture of continuous fiber-reinforced MMCs in view of analytical and experimental results, and MMC fiber-matrix interface failures.
Characteristics of Volcanic Soils in Landslide during the 2016 Kumamoto Earthquake, Japan
NASA Astrophysics Data System (ADS)
Hazarika, H.; Fukuoka, H.; Kokusho, T.; Sumartini, O.; Bhoopendra, D.
2017-12-01
There were many seismic subsidence, debris flows, landslides and slope failures, which occurred in Aso area due to the 2016 Kumamoto earthquake, Japan. This research aims to determine the failure mechanism of many mild slopes, and elucidate the strength characteristics of volcanic soils collected from the sites. A series of undrained static and cyclic triaxial tests, ring shear tests and direct shear tests were performed. Also, for further understanding of volcanic soils' material strength, X-ray powder diffraction analysis (XRD), X-ray fluorescence analysis (XRF), and Scanning electron microscope analysis (SEM) were performed. In this paper, preliminary results of the experimental testing program are discussed.
Lower cognitive function in patients with age-related macular degeneration: a meta-analysis
Zhou, Li-Xiao; Sun, Cheng-Lin; Wei, Li-Juan; Gu, Zhi-Min; Lv, Liang; Dang, Yalong
2016-01-01
Objective To investigate the cognitive impairment in patients with age-related macular degeneration (AMD). Methods Relevant articles were identified through a search of the following electronic databases through October 2015, without language restriction: 1) PubMed; 2) the Cochrane Library; 3) EMBASE; 4) ScienceDirect. Meta-analysis was conducted using STATA 12.0 software. Standardized mean differences with corresponding 95% confidence intervals were calculated. All of the included studies met the following four criteria: 1) the study design was a case–control or randomized controlled trial (RCT) study; 2) the study investigated cognitive function in the patient with AMD; 3) the diagnoses of AMD must be provided; 4) there were sufficient scores data to extract for evaluating cognitive function between cases and controls. The Newcastle–Ottawa Scale criteria were used to assess the methodological quality of the studies. Results Of the initial 278 literatures, only six case–control and one RCT studies met all of the inclusion criteria. A total of 794 AMD patients and 1,227 controls were included in this study. Five studies were performed with mini-mental state examination (MMSE), two studies with animal fluency, two studies with trail making test (TMT)-A and -B, one study with Mini-Cog. Results of the meta-analysis revealed lower cognitive function test scores in patients with AMD, especially with MMSE and Mini-Cog test (P≤0.001 for all). The results also showed that differences in the TMT-A (except AMD [total] vs controls) and TMT-B test had no statistical significance (P>0.01). The Newcastle–Ottawa Scale score was ≥5 for all of the included studies. Based on the sensitivity analysis, no single study influenced the overall pooled estimates. Conclusion This meta-analysis suggests lower cognitive function test scores in patients with AMD, especially with MMSE and Mini-Cog test. The other cognitive impairment screening tests, such as animal fluency test and TMT, need more studies to assess. PMID:26966358
NASA Astrophysics Data System (ADS)
Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.
The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.
Braden, B; Caspary, W F; Lembcke, B
1999-06-01
13C-urea breath tests have become clinical routine for the diagnosis of Helicobacter pylori infection and other isotope breath tests have been invented e.g. for gastric emptying or quantitative liver function testing. Recently, isotope-selective nondispersive infrared spectrometers (NDIRS) have been developed for the analysis of the 13CO2/12CO2-enrichment in breath. In this study, we prospectively tested the validity of a newly developed NDIRS in comparison to isotope ratio mass spectrometry (IRMS). 142 patients with dyspeptic symptoms were tested for Helicobacter pylori infection using the 13C-urea breath test. The isotope ratio analysis of the breath samples was performed in duplicate both using IRMS and NDIRS. The results of the baseline-corrected 13CO2-exhalation values between IRMS and NDIRS were in excellent agreement. The mean difference between both methods was 0.28 +/- 1.93 delta/1000. Evaluating the qualitative urea breath test results in reference to IRMS as the reference the NDIRS had a sensitivity of 97.8% and a specificity of 98.9%. The isotope-selective nondispersive infrared spectroscopy is going to become a reliable, but low-cost and easy-to-operate alternative to expensive isotope ratio mass spectrometry in the analysis of 13C-breath tests.
NASA Astrophysics Data System (ADS)
Oktaviana, P. P.; Fithriasari, K.
2018-04-01
Mostly Indonesian citizen consume vannamei shrimp as their food. Vannamei shrimp also is one of Indonesian exports comodities mainstay. Vannamei shrimp in the ponds and markets could be contaminated by Salmonella sp bacteria. This bacteria will endanger human health. Salmonella sp bacterial contamination on vannamei shrimp could be affected by many factors. This study is intended to identify what factors that supposedly influence the Salmonella sp bacterial contamination on vannamei shrimp. The researchers used the testing result of Salmonella sp bacterial contamination on vannamei shrimp as response variable. This response variable has two categories: 0 = if testing result indicate that there is no Salmonella sp on vannamei shrimp; 1 = if testing result indicate that there is Salmonella sp on vannamei shrimp. There are four factors that supposedly influence the Salmonella sp bacterial contamination on vannamei shrimp, which are the testing result of Salmonella sp bacterial contamination on farmer hand swab; the subdistrict of vannamei shrimp ponds; the fish processing unit supplied by; and the pond are in hectare. This four factors used as predictor variables. The analysis used is Binary Logit Model Approach according to the response variable that has two categories. The analysis result indicates that the factors or predictor variables which is significantly affect the Salmonella sp bacterial contamination on vannamei shrimp are the testing result of Salmonella sp bacterial contamination on farmer hand swab and the subdistrict of vannamei shrimp ponds.
RERTR-12 Insertion 2 Irradiation Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. M. Perez; G. S. Chang; D. M. Wachs
2012-09-01
The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.
Applications of Automation Methods for Nonlinear Fracture Test Analysis
NASA Technical Reports Server (NTRS)
Allen, Phillip A.; Wells, Douglas N.
2013-01-01
As fracture mechanics material testing evolves, the governing test standards continue to be refined to better reflect the latest understanding of the physics of the fracture processes involved. The traditional format of ASTM fracture testing standards, utilizing equations expressed directly in the text of the standard to assess the experimental result, is self-limiting in the complexity that can be reasonably captured. The use of automated analysis techniques to draw upon a rich, detailed solution database for assessing fracture mechanics tests provides a foundation for a new approach to testing standards that enables routine users to obtain highly reliable assessments of tests involving complex, non-linear fracture behavior. Herein, the case for automating the analysis of tests of surface cracks in tension in the elastic-plastic regime is utilized as an example of how such a database can be generated and implemented for use in the ASTM standards framework. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.
NASA Astrophysics Data System (ADS)
Rakkapao, Suttida; Prasitpong, Singha; Arayathanitkul, Kwan
2016-12-01
This study investigated the multiple-choice test of understanding of vectors (TUV), by applying item response theory (IRT). The difficulty, discriminatory, and guessing parameters of the TUV items were fit with the three-parameter logistic model of IRT, using the parscale program. The TUV ability is an ability parameter, here estimated assuming unidimensionality and local independence. Moreover, all distractors of the TUV were analyzed from item response curves (IRC) that represent simplified IRT. Data were gathered on 2392 science and engineering freshmen, from three universities in Thailand. The results revealed IRT analysis to be useful in assessing the test since its item parameters are independent of the ability parameters. The IRT framework reveals item-level information, and indicates appropriate ability ranges for the test. Moreover, the IRC analysis can be used to assess the effectiveness of the test's distractors. Both IRT and IRC approaches reveal test characteristics beyond those revealed by the classical analysis methods of tests. Test developers can apply these methods to diagnose and evaluate the features of items at various ability levels of test takers.
Finite Element Model Calibration Approach for Area I-X
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Reaves, Mercedes C.; Buehrle, Ralph D.; Templeton, Justin D.; Gaspar, James L.; Lazor, Daniel R.; Parks, Russell A.; Bartolotta, Paul A.
2010-01-01
Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of non-conventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pretest predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.
TACT: A Set of MSC/PATRAN- and MSC/NASTRAN- based Modal Correlation Tools
NASA Technical Reports Server (NTRS)
Marlowe, Jill M.; Dixon, Genevieve D.
1998-01-01
This paper describes the functionality and demonstrates the utility of the Test Analysis Correlation Tools (TACT), a suite of MSC/PATRAN Command Language (PCL) tools which automate the process of correlating finite element models to modal survey test data. The initial release of TACT provides a basic yet complete set of tools for performing correlation totally inside the PATRAN/NASTRAN environment. Features include a step-by-step menu structure, pre-test accelerometer set evaluation and selection, analysis and test result export/import in Universal File Format, calculation of frequency percent difference and cross-orthogonality correlation results using NASTRAN, creation and manipulation of mode pairs, and five different ways of viewing synchronized animations of analysis and test modal results. For the PATRAN-based analyst, TACT eliminates the repetitive, time-consuming and error-prone steps associated with transferring finite element data to a third-party modal correlation package, which allows the analyst to spend more time on the more challenging task of model updating. The usefulness of this software is presented using a case history, the correlation for a NASA Langley Research Center (LaRC) low aspect ratio research wind tunnel model. To demonstrate the improvements that TACT offers the MSC/PATRAN- and MSC/DIASTRAN- based structural analysis community, a comparison of the modal correlation process using TACT within PATRAN versus external third-party modal correlation packages is presented.
A Computational Approach for Model Update of an LS-DYNA Energy Absorbing Cell
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Jackson, Karen E.; Kellas, Sotiris
2008-01-01
NASA and its contractors are working on structural concepts for absorbing impact energy of aerospace vehicles. Recently, concepts in the form of multi-cell honeycomb-like structures designed to crush under load have been investigated for both space and aeronautics applications. Efforts to understand these concepts are progressing from tests of individual cells to tests of systems with hundreds of cells. Because of fabrication irregularities, geometry irregularities, and material properties uncertainties, the problem of reconciling analytical models, in particular LS-DYNA models, with experimental data is a challenge. A first look at the correlation results between single cell load/deflection data with LS-DYNA predictions showed problems which prompted additional work in this area. This paper describes a computational approach that uses analysis of variance, deterministic sampling techniques, response surface modeling, and genetic optimization to reconcile test with analysis results. Analysis of variance provides a screening technique for selection of critical parameters used when reconciling test with analysis. In this study, complete ignorance of the parameter distribution is assumed and, therefore, the value of any parameter within the range that is computed using the optimization procedure is considered to be equally likely. Mean values from tests are matched against LS-DYNA solutions by minimizing the square error using a genetic optimization. The paper presents the computational methodology along with results obtained using this approach.
Testing the mean for dependent business data.
Liang, Jiajuan; Martin, Linda
2008-01-01
In business data analysis, it is well known that the comparison of several means is usually carried out by the F-test in analysis of variance under the assumption of independently collected data from all populations. This assumption, however, is likely to be violated in survey data collected from various questionnaires or time-series data. As a result, it is not justifiable or problematic to apply the traditional F-test to comparison of dependent means directly. In this article, we develop a generalized F-test for comparing population means with dependent data. Simulation studies show that the proposed test has a simple approximate null distribution and feasible finite-sample properties. Applications of the proposed test in analysis of survey data and time-series data are illustrated by two real datasets.
Integrated Optical Design Analysis (IODA): New Test Data and Modeling Features
NASA Technical Reports Server (NTRS)
Moore, Jim; Troy, Ed; Patrick, Brian
2003-01-01
A general overview of the capabilities of the IODA ("Integrated Optical Design Analysis") exchange of data and modeling results between thermal, structures, optical design, and testing engineering disciplines. This presentation focuses on new features added to the software that allow measured test data to be imported into the IODA environment for post processing or comparisons with pretest model predictions. software is presented. IODA promotes efficient
Validation and structural analysis of the kinematics concept test
NASA Astrophysics Data System (ADS)
Lichtenberger, A.; Wagner, C.; Hofer, S. I.; Stern, E.; Vaterlaus, A.
2017-06-01
The kinematics concept test (KCT) is a multiple-choice test designed to evaluate students' conceptual understanding of kinematics at the high school level. The test comprises 49 multiple-choice items about velocity and acceleration, which are based on seven kinematic concepts and which make use of three different representations. In the first part of this article we describe the development and the validation process of the KCT. We applied the KCT to 338 Swiss high school students who attended traditional teaching in kinematics. We analyzed the response data to provide the psychometric properties of the test. In the second part we present the results of a structural analysis of the test. An exploratory factor analysis of 664 student answers finally uncovered the seven kinematics concepts as factors. However, the analysis revealed a hierarchical structure of concepts. At the higher level, mathematical concepts group together, and then split up into physics concepts at the lower level. Furthermore, students who seem to understand a concept in one representation have difficulties transferring the concept to similar problems in another representation. Both results have implications for teaching kinematics. First, teaching mathematical concepts beforehand might be beneficial for learning kinematics. Second, instructions have to be designed to teach students the change between different representations.
NASA Technical Reports Server (NTRS)
Nguyen, D. T.; Al-Nasra, M.; Zhang, Y.; Baddourah, M. A.; Agarwal, T. K.; Storaasli, O. O.; Carmona, E. A.
1991-01-01
Several parallel-vector computational improvements to the unconstrained optimization procedure are described which speed up the structural analysis-synthesis process. A fast parallel-vector Choleski-based equation solver, pvsolve, is incorporated into the well-known SAP-4 general-purpose finite-element code. The new code, denoted PV-SAP, is tested for static structural analysis. Initial results on a four processor CRAY 2 show that using pvsolve reduces the equation solution time by a factor of 14-16 over the original SAP-4 code. In addition, parallel-vector procedures for the Golden Block Search technique and the BFGS method are developed and tested for nonlinear unconstrained optimization. A parallel version of an iterative solver and the pvsolve direct solver are incorporated into the BFGS method. Preliminary results on nonlinear unconstrained optimization test problems, using pvsolve in the analysis, show excellent parallel-vector performance indicating that these parallel-vector algorithms can be used in a new generation of finite-element based structural design/analysis-synthesis codes.
[The research protocol VI: How to choose the appropriate statistical test. Inferential statistics].
Flores-Ruiz, Eric; Miranda-Novales, María Guadalupe; Villasís-Keever, Miguel Ángel
2017-01-01
The statistical analysis can be divided in two main components: descriptive analysis and inferential analysis. An inference is to elaborate conclusions from the tests performed with the data obtained from a sample of a population. Statistical tests are used in order to establish the probability that a conclusion obtained from a sample is applicable to the population from which it was obtained. However, choosing the appropriate statistical test in general poses a challenge for novice researchers. To choose the statistical test it is necessary to take into account three aspects: the research design, the number of measurements and the scale of measurement of the variables. Statistical tests are divided into two sets, parametric and nonparametric. Parametric tests can only be used if the data show a normal distribution. Choosing the right statistical test will make it easier for readers to understand and apply the results.
Differential Item Functioning Analysis for Accommodated versus Nonaccommodated Students
ERIC Educational Resources Information Center
Finch, Holmes; Barton, Karen; Meyer, Patrick
2009-01-01
The No Child Left Behind act resulted in an increased reliance on large-scale standardized tests to assess the progress of individual students as well as schools. In addition, emphasis was placed on including all students in the testing programs as well as those with disabilities. As a result, the role of testing accommodations has become more…
Lim, JaeHyoung; Oh, In Kyung; Han, Changsu; Huh, Yu Jeong; Jung, In-Kwa; Patkar, Ashwin A; Steffens, David C; Jang, Bo-Hyoung
2013-09-01
We performed a meta-analysis in order to determine which neuropsychological domains and tasks would be most sensitive for discriminating between patients with major depressive disorder (MDD) and healthy controls. Relevant articles were identified through a literature search of the PubMed and Cochrane Library databases for the period between January 1997 and May 2011. A meta-analysis was conducted using the standardized means of individual cognitive tests in each domain. The heterogeneity was assessed, and subgroup analyses according to age and medication status were performed to explore the sources of heterogeneity. A total of 22 trials involving 955 MDD patients and 7,664 healthy participants were selected for our meta-analysis. MDD patients showed significantly impaired results compared with healthy participants on the Digit Span and Continuous Performance Test in the attention domain; the Trail Making Test A (TMT-A) and the Digit Symbol Test in the processing speed domain; the Stroop Test, the Wisconsin Card Sorting Test, and Verbal Fluency in the executive function domain; and immediate verbal memory in the memory domain. The Finger Tapping Task, TMT-B, delayed verbal memory, and immediate and delayed visual memory failed to separate MDD patients from healthy controls. The results of subgroup analysis showed that performance of Verbal Fluency was significantly impaired in younger depressed patients (<60 years), and immediate visual memory was significantly reduced in depressed patients using antidepressants. Our findings have inevitable limitations arising from methodological issues inherent in the meta-analysis and we could not explain high heterogeneity between studies. Despite such limitations, current study has the strength of being the first meta-analysis which tried to specify cognitive function of depressed patients compared with healthy participants. And our findings may provide clinicians with further evidences that some cognitive tests in specific cognitive domains have sensitivity to discriminate MDD patients from healthy controls.
NASA Astrophysics Data System (ADS)
Tene, Yair; Tene, Noam; Tene, G.
1993-08-01
An interactive data fusion methodology of video, audio, and nonlinear structural dynamic analysis for potential application in forensic engineering is presented. The methodology was developed and successfully demonstrated in the analysis of heavy transportable bridge collapse during preparation for testing. Multiple bridge elements failures were identified after the collapse, including fracture, cracks and rupture of high performance structural materials. Videotape recording by hand held camcorder was the only source of information about the collapse sequence. The interactive data fusion methodology resulted in extracting relevant information form the videotape and from dynamic nonlinear structural analysis, leading to full account of the sequence of events during the bridge collapse.
Stress Analysis of Columns and Beam Columns by the Photoelastic Method
NASA Technical Reports Server (NTRS)
Ruffner, B F
1946-01-01
Principles of similarity and other factors in the design of models for photoelastic testing are discussed. Some approximate theoretical equations, useful in the analysis of results obtained from photoelastic tests are derived. Examples of the use of photoelastic techniques and the analysis of results as applied to uniform and tapered beam columns, circular rings, and statically indeterminate frames, are given. It is concluded that this method is an effective tool for the analysis of structures in which column action is present, particularly in tapered beam columns, and in statically indeterminate structures in which the distribution of loads in the structures is influenced by bending moments due to axial loads in one or more members.
Analysis of pre-flight modulator voltage calibration data for the Voyager plasma science experiment
NASA Technical Reports Server (NTRS)
Nastov, Ognen
1988-01-01
The Voyager Plasma Science (PLS) modulator calibration (MVM) data analysis was undertaken in order to check the correctness of the fast A/D converter formulas that connect low voltage monitor signals (MV) with digital outputs (DN), to determine the proportionality constants between the actual modulator grid potential (V) and the monitor voltage (MV), and to establish an algorithm to link the digitized readouts (DN) with the actual grid potential (V). The analysis results are surprising in that the derived conversion constants deviate by fairly significant amounts from their nominal values. However, it must be kept in mind that the test results which were used for analysis may be very imprecise. Even if it is assumed that the test result errors are very large, they do no appear to be capable to account for all discrepancies between the theoretical expectations and the results of the analysis. Measurements with the flight spare instrument appear to be the only means of investigating these effects further.
Pileggi, Claudia; Flotta, Domenico; Bianco, Aida; Nobile, Carmelo G A; Pavia, Maria
2014-07-01
Human-papillomavirus (HPV) DNA testing has been proposed as an alternative to primary cervical cancer screening using cytological testing. Review of the evidence shows that available data are conflicting for some aspects. The overall goal of the study is to update the performance of HPV DNA as stand-alone testing in primary cervical cancer screening, focusing particularly on the aspects related to the specificity profile of the HPV DNA testing in respect to cytology. We performed a meta-analysis of randomized controlled clinical trials. Eight articles were included in the meta-analysis. Three outcomes have been investigated: relative detection, relative specificity, and relative positive predictive value (PPV) of HPV DNA testing versus cytology. Overall evaluation of relative detection showed a significantly higher detection of CIN2+ and CIN3+ for HPV DNA testing versus cytology. Meta-analyses that considered all age groups showed a relative specificity that favored the cytology in detecting both CIN2+ and CIN3+ lesions whereas, in the ≥30 years' group, specificity of HPV DNA and cytology tests was similar in detecting both CIN2+ and CIN3+ lesions. Results of the pooled analysis on relative PPV showed a not significantly lower PPV of HPV DNA test over cytology. A main key finding of the study is that in women aged ≥30, has been found an almost overlapping specificity between the two screening tests in detecting CIN2 and above-grade lesions. Therefore, primary screening of cervical cancer by HPV DNA testing appears to offer the right balance between maximum detection of CIN2+ and adequate specificity, if performed in the age group ≥30 years. © 2013 UICC.
Brooks, M.H.; Schroder, L.J.; Malo, B.A.
1985-01-01
Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)
Applications of flight control system methods to an advanced combat rotorcraft
NASA Technical Reports Server (NTRS)
Tischler, Mark B.; Fletcher, Jay W.; Morris, Patrick M.; Tucker, George T.
1989-01-01
Advanced flight control system design, analysis, and testing methodologies developed at the Ames Research Center are applied in an analytical and flight test evaluation of the Advanced Digital Optical Control System (ADOCS) demonstrator. The primary objectives are to describe the knowledge gained about the implications of digital flight control system design for rotorcraft, and to illustrate the analysis of the resulting handling-qualities in the context of the proposed new handling-qualities specification for rotorcraft. Topics covered in-depth are digital flight control design and analysis methods, flight testing techniques, ADOCS handling-qualities evaluation results, and correlation of flight test results with analytical models and the proposed handling-qualities specification. The evaluation of the ADOCS demonstrator indicates desirable response characteristics based on equivalent damping and frequency, but undersirably large effective time-delays (exceeding 240 m sec in all axes). Piloted handling-qualities are found to be desirable or adequate for all low, medium, and high pilot gain tasks; but handling-qualities are inadequate for ultra-high gain tasks such as slope and running landings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syring, R.P.; Grubb, R.L.
1979-09-30
This document reports on the following: (1) experimental determination of the response of 16 basic structural elements and 7 B-52 components to simulated nuclear overpressure environments (utilizing Sandia Corporation's Thunderpipe Shock Tube), (2) analysis of these test specimens utilizing the NOVA-2 computer program, and (3) correlation of test and analysis results.
NASA Technical Reports Server (NTRS)
Spiller, Olaf
1991-01-01
The provisions applied to the Airbus A340 wing wiring against lightning indirect effects are presented. The construction and installation of the wiring's shielding systems are described, and the analysis and tests performed to determine the effectiveness of the measures taken are discussed. A first evaluation of the results of the theoretical analysis together with the provisional results of tests indicate a sufficient safety margin between required and achieved protection levels.
Gloria, E M; Fonseca, H; Calori-Domingues, M A; Souza, I M
1998-01-01
The results of the black light test for aflatoxin-contaminated maize carried out in a large food factory in the State of São Paulo was evaluated against bi-directional thin layer chromatography (TLC) analysis for 286 samples of maize. All 286 samples were accepted by the black light test (< 7 fluorescent points), however, the results from TLC analysis showed that 96 samples were contaminated and 14 showed aflatoxin B1 contamination levels higher than 20 micrograms/kg. There were 14 false negative results and no false positives and out of the 14 samples, six did not show visible fluorescent points. If the rejection criterion of one or more fluorescent points were applied, the six samples would be accepted by the black light test. But, in this case, 95 samples would be rejected and 87 results would be false positives because they did not have contamination levels over 20 micrograms/kg which is the acceptance limit of the black light test. The results indicate that the black light test, as utilized by this factory, was not able to indicate lots with possible contamination and the black light test, as recommended in the literature, would produce a high number of false positives. It is necessary to make more studies on the use of black light as a screening test for possible aflatoxin B1-contaminated maize.
Liu, Li; Sabo, Aniko; Neale, Benjamin M.; Nagaswamy, Uma; Stevens, Christine; Lim, Elaine; Bodea, Corneliu A.; Muzny, Donna; Reid, Jeffrey G.; Banks, Eric; Coon, Hillary; DePristo, Mark; Dinh, Huyen; Fennel, Tim; Flannick, Jason; Gabriel, Stacey; Garimella, Kiran; Gross, Shannon; Hawes, Alicia; Lewis, Lora; Makarov, Vladimir; Maguire, Jared; Newsham, Irene; Poplin, Ryan; Ripke, Stephan; Shakir, Khalid; Samocha, Kaitlin E.; Wu, Yuanqing; Boerwinkle, Eric; Buxbaum, Joseph D.; Cook, Edwin H.; Devlin, Bernie; Schellenberg, Gerard D.; Sutcliffe, James S.; Daly, Mark J.; Gibbs, Richard A.; Roeder, Kathryn
2013-01-01
We report on results from whole-exome sequencing (WES) of 1,039 subjects diagnosed with autism spectrum disorders (ASD) and 870 controls selected from the NIMH repository to be of similar ancestry to cases. The WES data came from two centers using different methods to produce sequence and to call variants from it. Therefore, an initial goal was to ensure the distribution of rare variation was similar for data from different centers. This proved straightforward by filtering called variants by fraction of missing data, read depth, and balance of alternative to reference reads. Results were evaluated using seven samples sequenced at both centers and by results from the association study. Next we addressed how the data and/or results from the centers should be combined. Gene-based analyses of association was an obvious choice, but should statistics for association be combined across centers (meta-analysis) or should data be combined and then analyzed (mega-analysis)? Because of the nature of many gene-based tests, we showed by theory and simulations that mega-analysis has better power than meta-analysis. Finally, before analyzing the data for association, we explored the impact of population structure on rare variant analysis in these data. Like other recent studies, we found evidence that population structure can confound case-control studies by the clustering of rare variants in ancestry space; yet, unlike some recent studies, for these data we found that principal component-based analyses were sufficient to control for ancestry and produce test statistics with appropriate distributions. After using a variety of gene-based tests and both meta- and mega-analysis, we found no new risk genes for ASD in this sample. Our results suggest that standard gene-based tests will require much larger samples of cases and controls before being effective for gene discovery, even for a disorder like ASD. PMID:23593035
Smith, Anthony Marius; Smouse, Shannon Lucrecia; Tau, Nomsa Pauline; Bamford, Colleen; Moodley, Vineshree Mischka; Jacobs, Charlene; McCarthy, Kerrigan Mary; Lourens, Adré; Keddy, Karen Helena
2017-09-29
Workers in clinical microbiology laboratories are exposed to a variety of pathogenic microorganisms. Salmonella species is among the most commonly reported bacterial causes of laboratory-acquired infections. We report on three cases of laboratory-acquired Salmonella enterica serotype Typhi (Salmonella Typhi) infection which occurred over the period 2012 to 2016 in South Africa. Laboratory investigation included phenotypic and genotypic characterization of isolates. Phenotypic analysis included standard microbiological identification techniques, serotyping and antimicrobial susceptibility testing. Genotypic analysis included the molecular subtyping methodologies of pulsed-field gel electrophoresis analysis, multilocus sequence typing and whole-genome sequencing (WGS); with WGS data analysis including phylogenetic analysis based upon comparison of single nucleotide polymorphism profiles of isolates. All cases of laboratory-acquired infection were most likely the result of lapses in good laboratory practice and laboratory safety. The following critical issues were highlighted. There was misdiagnosis and misreporting of Salmonella Typhi as nontyphoidal Salmonella by a diagnostic laboratory, with associated public health implications. We highlight issues concerning the importance of accurate fluoroquinolone susceptibility testing and interpretation of results according to updated guidelines. We describe potential shortcomings of a single disk susceptibility screening test for fluoroquinolone susceptibility and suggest that confirmatory minimum inhibitory concentration testing should always be performed in cases of invasive Salmonella infections. These antimicrobial susceptibility testing issues resulted in inappropriate ciprofloxacin therapy which may have been responsible for failure in clearance of pathogen from patients. Salmonella Typhi capsular polysaccharide vaccine was not protective in one case, possibly secondarily to a faulty vaccine. Molecular subtyping of isolates proved effective to investigate the genetic relatedness of isolates. Molecular subtyping data interpreted together with epidemiological data allowed us to pinpoint the most likely sources for our cases of laboratory-acquired infection.
Kim, In-Ah; den-Hollander, Elyn; Lee, Hye-Seong
2018-03-01
Descriptive analysis with a trained sensory panel has thus far been the most well defined methodology to characterize various products. However, in practical terms, intensive training in descriptive analysis has been recognized as a serious defect. To overcome this limitation, various novel rapid sensory profiling methodologies have been suggested in the literature. Among these, attribute-based methodologies such as check-all-that-apply (CATA) questions showed results comparable to those of conventional sensory descriptive analysis. Kim, Hopkinson, van Hout, and Lee (2017a, 2017b) have proposed a novel attribute-based methodology termed the two-step rating-based 'double-faced applicability' test with a novel output measure of applicability magnitude (d' A ) for measuring consumers' product usage experience throughout various product usage stages. In this paper, the potential of the two-step rating-based 'double-faced applicability' test with d' A was investigated as an alternative to conventional sensory descriptive analysis in terms of sensory characterization and product discrimination. Twelve commercial spread products were evaluated using both conventional sensory descriptive analysis with a trained sensory panel and two-step rating-based 'double-faced applicability' test with an untrained sensory panel. The results demonstrated that the 'double-faced applicability' test can be used to provide a direct measure of the applicability magnitude of sensory attributes of the samples tested in terms of d' A for sensory characterization of individual samples and multiple sample comparisons. This suggests that when the appropriate list of attributes to be used in the questionnaire is already available, the two-step rating-based 'double-faced applicability' test with d' A can be used as a more efficient alternative to conventional descriptive analysis, without requiring any intensive training process. Copyright © 2017 Elsevier Ltd. All rights reserved.
Testing and analysis of LWT and SCB properties of asphaltic concrete mixtures.
DOT National Transportation Integrated Search
2011-06-01
The objective of this research is to implement the loaded wheel tracker and to evaluate a simplified semi-circular bend test as an end result parameter for testing asphaltic concrete mixtures. The research will focus on testing both plant produced lo...
Conventional fuel tank blunt impact tests : test and analysis results
DOT National Transportation Integrated Search
2014-04-02
The Federal Railroad Administrations Office of Research : and Development is conducting research into fuel tank : crashworthiness. A series of impact tests are planned to : measure fuel tank deformation under two types of dynamic : loading conditi...
Occupied Volume Integrity Testing : Elastic Test Results and Analyses
DOT National Transportation Integrated Search
2011-09-21
Federal Railroad Administration (FRA) and the Volpe Center have been conducting research into developing an alternative method of demonstrating occupied volume integrity (OVI) through a combination of testing and analysis. Previous works have been pu...
Spacelab scrubber analysis and test support
NASA Technical Reports Server (NTRS)
1979-01-01
Contaminants to be used in qualification and development tests of the add-on charcoal bed scrubber were established, along with rates and methods for their introduction. The contaminant levels to be achieved were predicted and test results were analyzed.
Analysis of aquifer tests in the Punjab region of West Pakistan
Bennett, Gordon D.; ,; Sheikh, Ijaz Ahmed; Alr, Sabire
1967-01-01
The results of 141 pumping tests in the Punjab Plain of West Pakistan are reported. Methods of test analysis are described in detail, and an outline of the theory underlying these methods is given. The lateral permeability of the screened interval is given for all tests; the specific yield of the material at water-table depth is given for 1(6 tests; and the vertical permeability of the material between the water table and the top of the screen is given for 14 tests. The lateral permeabilities are predominantly in the range 0.001 to 0.006 cfs per sq ft; the average value is 0.0032 cfs per sq ft. Specific yields generally range from 0.02 to 0.26; the average value is 0.14. All vertical permeability results fall in the range 10 -5 to 10 -3 cfs per sq ft.
The pitfalls of hair analysis for toxicants in clinical practice: three case reports.
Frisch, Melissa; Schwartz, Brian S
2002-01-01
Hair analysis is used to assess exposure to heavy metals in patients presenting with nonspecific symptoms and is a commonly used procedure in patients referred to our clinic. We are frequently called on to evaluate patients who have health-related concerns as a result of hair analysis. Three patients first presented to outside physicians with nonspecific, multisystemic symptoms. A panel of analytes was measured in hair, and one or more values were interpreted as elevated. As a result of the hair analysis and other unconventional diagnostic tests, the patients presented to us believing they suffered from metal toxicity. In this paper we review the clinical efficacy of this procedure within the context of a patient population with somatic disorders and no clear risk factors for metal intoxication. We also review limitations of hair analysis in this setting; these limitations include patient factors such as low pretest probability of disease and test factors such as the lack of validation of analytic techniques, the inability to discern between exogenous contaminants and endogenous toxicants in hair, the variability of analytic procedures, low interlaboratory reliability, and the increased likelihood of false positive test results in the measurement of panels of analytes. PMID:11940463
Properties of Tuffs, Grout and Other Materials.
1982-01-01
analysis , and tested in uniaxial strain. Table 2 presents the physical properties, ultrasonic data, and the per- manent volume compaction resulting from the... methods provide an accuracy of ±2% on pressure and stress measure- ments. Strain Measurements - Strains are measured using cantilever arms inside the...that are used in nuclear blast effects analysis , and specifically to assist in the analysis of the grout sphere explosive tests being conducted by the
Statistical Tutorial | Center for Cancer Research
Recent advances in cancer biology have resulted in the need for increased statistical analysis of research data. ST is designed as a follow up to Statistical Analysis of Research Data (SARD) held in April 2018. The tutorial will apply the general principles of statistical analysis of research data including descriptive statistics, z- and t-tests of means and mean differences, simple and multiple linear regression, ANOVA tests, and Chi-Squared distribution.
Araújo, Marcelo Marotta; Lauria, Andrezza; Mendes, Marcelo Breno Meneses; Claro, Ana Paula Rosifini Alves; Claro, Cristiane Aparecida de Assis; Moreira, Roger William Fernandes
2015-12-01
The aim of this study was to analyze, through Vickers hardness test and photoelasticity analysis, pre-bent areas, manually bent areas, and areas without bends of 10-mm advancement pre-bent titanium plates (Leibinger system). The work was divided into three groups: group I-region without bend, group II-region of 90° manual bend, and group III-region of 90° pre-fabricated bends. All the materials were evaluated through hardness analysis by the Vickers hardness test, stress analysis by residual images obtained in a polariscope, and photoelastic analysis by reflection during the manual bending. The data obtained from the hardness tests were statistically analyzed using ANOVA and Tukey's tests at a significance level of 5 %. The pre-bent plate (group III) showed hardness means statistically significantly higher (P < 0.05) than those of the other groups (I-region without bends, II-90° manually bent region). Through the study of photoelastic reflection, it was possible to identify that the stress gradually increased, reaching a pink color (1.81 δ / λ), as the bending was performed. A general analysis of the results showed that the bent plate region of pre-bent titanium presented the best results.
Workplace drug testing in Italy: findings about second-stage testing.
Vignali, Claudia; Stramesi, Cristiana; Morini, Luca; San Bartolomeo, Paolo; Groppi, Angelo
2015-03-01
Workplace Drug Testing (WDT) in Italy includes two levels of monitoring: a first stage concerning drug testing on urine samples and a second involving both urine and hair analysis. The second stage is performed only on workers who tested positive at the first level. We analyzed urine and hair specimens from 120 workers undergoing second-level testing between 2009 and 2012. Eighty percent of them had tested positive for cannabinoids during the first level analysis, and 15.8% for cocaine. Both urine and hair samples were analyzed in order to find the following drugs of abuse: amphetamines, buprenorphine, cannabinoids, cocaine, ecstasy, methadone, and opiates. Urine analyses were performed by immunological screening (EMIT); urine confirmatory tests and hair analyses were performed by gas chromatography-mass spectrometry (GC-MS). As regards second-stage testing on urine samples, 71.2% of workers were always negative, whereas 23.9% tested positive at least once for cannabinoids and 2.5% for cocaine. Hair analyses produced surprising results: 61.9% of hair samples tested negative, only 6.2% tested positive for cannabinoids, whereas 28.8% tested positive for cocaine. These findings confirm that second-level surveillance of WDT, which includes hair analysis, is very effective because it highlights drug intake - sometimes heavy - that cannot be revealed only through urine analyses. The employees for whom drug addiction is proved can begin rehabilitation, while keeping their job. Eventually, our results confirmed the widespread and undeclared use of cocaine in Italy. Copyright © 2014 John Wiley & Sons, Ltd.
Talamo, Thomas S.; Losos, Frank J.; Mercer, Donald W.
1984-01-01
We have developed a microcomputer based system for interpretative reporting of creatine kinase (CK) and lactate dehydrogenase (LDH) isoenzyme studies. Patient demographic data and test results (total CK, CK-MB, LD-1, and LD-2) are entered manually through the keyboard. The test results are compared with normal range values and an interpretative report is generated. This report consists of all pertinent demographic information with a graphic display of up to 12 previous CK and LDH isoenzyme determinations. Diagnostic interpretative statements are printed beneath the graphic display following analysis of previously entered test results. The combination of graphic data display and interpretations based on analysis of up to 12 previous specimens provides useful and accurate information to the cardiologist.
Advanced superposition methods for high speed turbopump vibration analysis
NASA Technical Reports Server (NTRS)
Nielson, C. E.; Campany, A. D.
1981-01-01
The small, high pressure Mark 48 liquid hydrogen turbopump was analyzed and dynamically tested to determine the cause of high speed vibration at an operating speed of 92,400 rpm. This approaches the design point operating speed of 95,000 rpm. The initial dynamic analysis in the design stage and subsequent further analysis of the rotor only dynamics failed to predict the vibration characteristics found during testing. An advanced procedure for dynamics analysis was used in this investigation. The procedure involves developing accurate dynamic models of the rotor assembly and casing assembly by finite element analysis. The dynamically instrumented assemblies are independently rap tested to verify the analytical models. The verified models are then combined by modal superposition techniques to develop a completed turbopump model where dynamic characteristics are determined. The results of the dynamic testing and analysis obtained are presented and methods of moving the high speed vibration characteristics to speeds above the operating range are recommended. Recommendations for use of these advanced dynamic analysis procedures during initial design phases are given.
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.
2001-01-01
This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.
Statistical analysis of 59 inspected SSME HPFTP turbine blades (uncracked and cracked)
NASA Technical Reports Server (NTRS)
Wheeler, John T.
1987-01-01
The numerical results of statistical analysis of the test data of Space Shuttle Main Engine high pressure fuel turbopump second-stage turbine blades, including some with cracks are presented. Several statistical methods use the test data to determine the application of differences in frequency variations between the uncracked and cracked blades.
Medical microbiological analysis of Apollo-Soyuz test project crewmembers
NASA Technical Reports Server (NTRS)
Taylor, G. R.; Zaloguev, S. N.
1976-01-01
The procedures and results of the Microbial Exchange Experiment (AR-002) of the Apollo-Soyuz Test Project are described. Included in the discussion of procedural aspects are methods and materials, in-flight microbial specimen collection, and preliminary analysis of microbial specimens. Medically important microorganisms recovered from both Apollo and Soyuz crewmen are evaluated.
Filtrates and Residues: Qualitative Analysis of Some Transition Metals.
ERIC Educational Resources Information Center
Kilner, Cary
1985-01-01
Describes a qualitative analysis laboratory in which students examine specific precipitates that can be used to identify copper, cobalt, nickel, and iron cations. The objective of the laboratory is to determine which test or sequence of tests unambiguously identifies each cation and to use the results to identify several unknowns. (JN)
Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy
ERIC Educational Resources Information Center
Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.
2013-01-01
An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…
Solar Dynamics Observatory On-Orbit Jitter Testing, Analysis, and Mitigation Plans
NASA Technical Reports Server (NTRS)
Liu, Kuo-Chia; Blaurock, Carl A.; Bourkland, Kristin L.; Morgenstern, Wendy M.; Maghami, Peiman G.
2011-01-01
The recently launched Solar Dynamics Observatory (SDO) has two science instruments onboard that required sub-arcsecond pointing stability. Significant effort has been spent pre-launch to characterize the disturbances sources and validating jitter level at the component, sub-assembly, and spacecraft levels. However, an end-to-end jitter test emulating the flight condition was not performed on the ground due to cost and risk concerns. As a result, the true jitter level experienced on orbit remained uncertain prior to launch. Based on the pre-launch analysis, several operational constraints were placed on the observatory aimed to minimize the instrument jitter levels. If the actual jitter is below the analysis predictions, these operational constraints can be relaxed to reduce the burden of the flight operations team. The SDO team designed a three-day jitter test, utilizing the instrument sensors to measure pointing jitter up to 256 Hz. The test results were compared to pre-launch analysis predictions, used to determine which operational constraints can be relaxed, and analyzed for setting the jitter mitigation strategies for future SDO operations.
Compression After Impact on Honeycomb Core Sandwich Panels with Thin Facesheets, Part 2: Analysis
NASA Technical Reports Server (NTRS)
Mcquigg, Thomas D.; Kapania, Rakesh K.; Scotti, Stephen J.; Walker, Sandra P.
2012-01-01
A two part research study has been completed on the topic of compression after impact (CAI) of thin facesheet honeycomb core sandwich panels. The research has focused on both experiments and analysis in an effort to establish and validate a new understanding of the damage tolerance of these materials. Part 2, the subject of the current paper, is focused on the analysis, which corresponds to the CAI testings described in Part 1. Of interest, are sandwich panels, with aerospace applications, which consist of very thin, woven S2-fiberglass (with MTM45-1 epoxy) facesheets adhered to a Nomex honeycomb core. Two sets of materials, which were identical with the exception of the density of the honeycomb core, were tested in Part 1. The results highlighted the need for analysis methods which taken into account multiple failure modes. A finite element model (FEM) is developed here, in Part 2. A commercial implementation of the Multicontinuum Failure Theory (MCT) for progressive failure analysis (PFA) in composite laminates, Helius:MCT, is included in this model. The inclusion of PFA in the present model provided a new, unique ability to account for multiple failure modes. In addition, significant impact damage detail is included in the model. A sensitivity study, used to assess the effect of each damage parameter on overall analysis results, is included in an appendix. Analysis results are compared to the experimental results for each of the 32 CAI sandwich panel specimens tested to failure. The failure of each specimen is predicted using the high-fidelity, physicsbased analysis model developed here, and the results highlight key improvements in the understanding of honeycomb core sandwich panel CAI failure. Finally, a parametric study highlights the strength benefits compared to mass penalty for various core densities.
Types of Sensory Integrative Dysfunction among Disabled Learners
ERIC Educational Resources Information Center
Ayres, A. Jean
1972-01-01
R-technique factor analysis was used to correlate results of sensorimotor, psycholinguistic and cognitive tests given to California children with learning disabilities. Results show not all children with specific neural disorders perform poorly on related tests where low scores would be expected. (PD)
Škrbić, Biljana; Héberger, Károly; Durišić-Mladenović, Nataša
2013-10-01
Sum of ranking differences (SRD) was applied for comparing multianalyte results obtained by several analytical methods used in one or in different laboratories, i.e., for ranking the overall performances of the methods (or laboratories) in simultaneous determination of the same set of analytes. The data sets for testing of the SRD applicability contained the results reported during one of the proficiency tests (PTs) organized by EU Reference Laboratory for Polycyclic Aromatic Hydrocarbons (EU-RL-PAH). In this way, the SRD was also tested as a discriminant method alternative to existing average performance scores used to compare mutlianalyte PT results. SRD should be used along with the z scores--the most commonly used PT performance statistics. SRD was further developed to handle the same rankings (ties) among laboratories. Two benchmark concentration series were selected as reference: (a) the assigned PAH concentrations (determined precisely beforehand by the EU-RL-PAH) and (b) the averages of all individual PAH concentrations determined by each laboratory. Ranking relative to the assigned values and also to the average (or median) values pointed to the laboratories with the most extreme results, as well as revealed groups of laboratories with similar overall performances. SRD reveals differences between methods or laboratories even if classical test(s) cannot. The ranking was validated using comparison of ranks by random numbers (a randomization test) and using seven folds cross-validation, which highlighted the similarities among the (methods used in) laboratories. Principal component analysis and hierarchical cluster analysis justified the findings based on SRD ranking/grouping. If the PAH-concentrations are row-scaled, (i.e., z scores are analyzed as input for ranking) SRD can still be used for checking the normality of errors. Moreover, cross-validation of SRD on z scores groups the laboratories similarly. The SRD technique is general in nature, i.e., it can be applied to any experimental problem in which multianalyte results obtained either by several analytical procedures, analysts, instruments, or laboratories need to be compared.
Peleato, Nicolás M; Andrews, Robert C
2015-01-01
This work investigated the application of several fluorescence excitation-emission matrix analysis methods as natural organic matter (NOM) indicators for use in predicting the formation of trihalomethanes (THMs) and haloacetic acids (HAAs). Waters from four different sources (two rivers and two lakes) were subjected to jar testing followed by 24hr disinfection by-product formation tests using chlorine. NOM was quantified using three common measures: dissolved organic carbon, ultraviolet absorbance at 254 nm, and specific ultraviolet absorbance as well as by principal component analysis, peak picking, and parallel factor analysis of fluorescence spectra. Based on multi-linear modeling of THMs and HAAs, principle component (PC) scores resulted in the lowest mean squared prediction error of cross-folded test sets (THMs: 43.7 (μg/L)(2), HAAs: 233.3 (μg/L)(2)). Inclusion of principle components representative of protein-like material significantly decreased prediction error for both THMs and HAAs. Parallel factor analysis did not identify a protein-like component and resulted in prediction errors similar to traditional NOM surrogates as well as fluorescence peak picking. These results support the value of fluorescence excitation-emission matrix-principal component analysis as a suitable NOM indicator in predicting the formation of THMs and HAAs for the water sources studied. Copyright © 2014. Published by Elsevier B.V.
Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines
NASA Technical Reports Server (NTRS)
Simonyi, P. S.; Boyle, R. J.
1991-01-01
An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40-50 percent shorter in axial length than conventional state-of-the-art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predicted results from a quasi-3D inviscid and boundary layer analysis, called MTSB (Meridl/Tsonic/Blayer). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.
Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines
NASA Technical Reports Server (NTRS)
Simonyi, P. S.; Boyle, R. J.
1991-01-01
An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40 to 50 percent shorter in axial length than conventional state of the art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predict results from a quasi-3D inviscid and boundary layer analysis, called Meridl/Tsonic/Blayer (MTSB). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.
Identifying students with dyslexia in higher education.
Tops, Wim; Callens, Maaike; Lammertyn, Jan; Van Hees, Valérie; Brysbaert, Marc
2012-10-01
An increasing number of students with dyslexia enter higher education. As a result, there is a growing need for standardized diagnosis. Previous research has suggested that a small number of tests may suffice to reliably assess students with dyslexia, but these studies were based on post hoc discriminant analysis, which tends to overestimate the percentage of systematic variance, and were limited to the English language (and the Anglo-Saxon education system). Therefore, we repeated the research in a non-English language (Dutch) and we selected variables on the basis of a prediction analysis. The results of our study confirm that it is not necessary to administer a wide range of tests to diagnose dyslexia in (young) adults. Three tests sufficed: word reading, word spelling and phonological awareness, in line with the proposal that higher education students with dyslexia continue to have specific problems with reading and writing. We also show that a traditional postdiction analysis selects more variables of importance than the prediction analysis. However, these extra variables explain study-specific variance and do not result in more predictive power of the model.
Crack cause analysis of a graphite nozzle throat insert
NASA Astrophysics Data System (ADS)
Sun, Lin; Bao, Futing; Zhao, Yu; Hou, Lian; Hui, Weihua; Zhang, Ning; Shi, Wei
2017-08-01
With an objective to determine the failure cause of a throughout crack at an angle of 45° and a breach during a firing test, a simplified analysis procedure with consideration of the structure gap was established to simulate the thermo-structural response of a nozzle. By neglecting erosion and pyrolysis of the insulating materials and establishing temperature-dependent or anisotropic material models, ANSYS Parameter Design Language codes were written to perform the fully coupled thermal-structural simulation. A Quasi-1D flow was calculated for supplying boundary conditions. Study on mesh independence and time step independence was also conducted to evaluate simulated results. It was found that shortly after ignition, compressive stress in the x direction and tensile stress in the y direction contributed to anomalies. And through contact status analysis, inappropriate gap design was regarded as the origin of the too large stress, which was the primary cause of these anomalies during firing test. Simulation results were in good agreement with firing test results. In addition, the simplified analysis procedure was proven effective. Gap size should be seriously dealt with in the future design.
Measurement of antinuclear antibodies and their fine specificities: time for a change in strategy?
Otten, Henny G; Brummelhuis, Walter J; Fritsch-Stork, Ruth; Leavis, Helen L; Wisse, Bram W; van Laar, Jacob M; Derksen, Ronald H W M
2017-01-01
The current strategy for antinuclear antibody (ANA) analysis involves screening for presence with a subsequent detailed analysis of their specificity. The aim of this study is to compare the clinical and financial efficacy of this strategy between different commercial tests in a large cohort of unselected patients. In all consecutive 1030 patients associations were defined between results from different ANA test systems and the pre-test probability for connective tissue disease (CTDs). Test systems were used for screening (ANA-IIF vs. CTD screen) and definition of their fine specificity (profile 3 line blot vs. CTD single analytes). Positive ANA-IIF and/or CTD screen results were found in 304 sera. Further analysis for ANA-specificity by profile 3 line blot and CTD single analytes showed 86 discrepant results of which more than a third are clinically relevant, with the CTD single analyte assay performing better than the line blot in supporting or confirming the presence of a CTD. Autoantigens present in one test but absent in the other were of minor practical use. The ANA screening and identification strategies currently employed are not cost-effective as 83% of tests were performed in order to find specific autoantibodies in patients without the fitting clinical signs or symptoms. This causes many unexpected positive results and subsequent confusion with regard to interpretation. We advocate that some autoantigens should be excluded from the line blot and CTD assays and propose the use of a cost-effective and selective ANA specificity testing purely based on clinical guidance.
Fabrication and verification testing of ETM 30 cm diameter ion thrusters
NASA Technical Reports Server (NTRS)
Collett, C.
1977-01-01
Engineering model designs and acceptance tests are described for the 800 and 900 series 30 cm electron bombardment thrustors. Modifications to the test console for a 1000 hr verification test were made. The 10,000 hr endurance test of the S/N 701 thruster is described, and post test analysis results are included.
ROC and Loss Function Analysis in Sequential Testing
ERIC Educational Resources Information Center
Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.
2006-01-01
Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…
Development and Flight Testing of an Adaptive Vehicle Health-Monitoring Architecture
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Taylor, B. Douglas; Brett, Rube R.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.
2002-01-01
On going development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle, and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. The expert system is parameterized, which makes it adaptable to be trained to both a user's subject reasoning and existing quantitative analytic tools. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation and, data acquisition, storage and retrieval.
Titanium Honeycomb Panel Testing
NASA Technical Reports Server (NTRS)
Richards, W. Lance; Thompson, Randolph C.
1996-01-01
Thermal-mechanical tests were performed on a titanium honeycomb sandwich panel to experimentally validate the hypersonic wing panel concept and compare test data with analysis. Details of the test article, test fixture development, instrumentation, and test results are presented. After extensive testing to 900 deg. F, non-destructive evaluation of the panel has not detected any significant structural degradation caused by the applied thermal-mechanical loads.
Ultrasonic test of resistance spot welds based on wavelet package analysis.
Liu, Jing; Xu, Guocheng; Gu, Xiaopeng; Zhou, Guanghao
2015-02-01
In this paper, ultrasonic test of spot welds for stainless steel sheets has been studied. It is indicated that traditional ultrasonic signal analysis in either time domain or frequency domain remains inadequate to evaluate the nugget diameter of spot welds. However, the method based on wavelet package analysis in time-frequency domain can easily distinguish the nugget from the corona bond by extracting high-frequency signals in different positions of spot welds, thereby quantitatively evaluating the nugget diameter. The results of ultrasonic test fit the actual measured value well. Mean value of normal distribution of error statistics is 0.00187, and the standard deviation is 0.1392. Furthermore, the quality of spot welds was evaluated, and it is showed ultrasonic nondestructive test based on wavelet packet analysis can be used to evaluate the quality of spot welds, and it is more reliable than single tensile destructive test. Copyright © 2014 Elsevier B.V. All rights reserved.
Methods Used in Economic Evaluations of Chronic Kidney Disease Testing — A Systematic Review
Sutton, Andrew J.; Breheny, Katie; Deeks, Jon; Khunti, Kamlesh; Sharpe, Claire; Ottridge, Ryan S.; Stevens, Paul E.; Cockwell, Paul; Kalra, Philp A.; Lamb, Edmund J.
2015-01-01
Background The prevalence of chronic kidney disease (CKD) is high in general populations around the world. Targeted testing and screening for CKD are often conducted to help identify individuals that may benefit from treatment to ameliorate or prevent their disease progression. Aims This systematic review examines the methods used in economic evaluations of testing and screening in CKD, with a particular focus on whether test accuracy has been considered, and how analysis has incorporated issues that may be important to the patient, such as the impact of testing on quality of life and the costs they incur. Methods Articles that described model-based economic evaluations of patient testing interventions focused on CKD were identified through the searching of electronic databases and the hand searching of the bibliographies of the included studies. Results The initial electronic searches identified 2,671 papers of which 21 were included in the final review. Eighteen studies focused on proteinuria, three evaluated glomerular filtration rate testing and one included both tests. The full impact of inaccurate test results was frequently not considered in economic evaluations in this setting as a societal perspective was rarely adopted. The impact of false positive tests on patients in terms of the costs incurred in re-attending for repeat testing, and the anxiety associated with a positive test was almost always overlooked. In one study where the impact of a false positive test on patient quality of life was examined in sensitivity analysis, it had a significant impact on the conclusions drawn from the model. Conclusion Future economic evaluations of kidney function testing should examine testing and monitoring pathways from the perspective of patients, to ensure that issues that are important to patients, such as the possibility of inaccurate test results, are properly considered in the analysis. PMID:26465773
Special environmental control and life support equipment test analyses and hardware
NASA Technical Reports Server (NTRS)
Callahan, David M.
1995-01-01
This final report summarizes NAS8-38250 contract events, 'Special Environmental Control and Life Support Systems Test Analysis and Hardware'. This report is technical and includes programmatic development. Key to the success of this contract was the evaluation of Environmental Control and Life Support Systems (ECLSS) test results via sophisticated laboratory analysis capabilities. The history of the contract, including all subcontracts, is followed by the support and development of each Task.
Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye
2016-01-13
A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.
Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test
NASA Technical Reports Server (NTRS)
Bradshaw, Heather
2012-01-01
This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.
Mechanical testing and finite element analysis of orthodontic teardrop loop.
Coimbra, Maria Elisa Rodrigues; Penedo, Norman Duque; de Gouvêa, Jayme Pereira; Elias, Carlos Nelson; de Souza Araújo, Mônica Tirre; Coelho, Paulo Guilherme
2008-02-01
Understanding how teeth move in response to mechanical loads is an important aspect of orthodontic treatment. Treatment planning should include consideration of the appliances that will meet the desired loading of the teeth to result in optimized treatment outcomes. The purpose of this study was to evaluate the use of computer simulation to predict the force and the torsion obtained after the activation of tear drop loops of 3 heights. Seventy-five retraction loops were divided into 3 groups according to height (6, 7, and 8 mm). The loops were subjected to tensile load through displacements of 0.5, 1.0, 1.5, and 2.0 mm, and the resulting forces and torques were recorded. The loops were designed in AutoCAD software(2005; Autodesk Systems, Alpharetta, GA), and finite element analysis was performed with Ansys software(version 7.0; Swanson Analysis System, Canonsburg, PA). Statistical analysis of the mechanical experiment results was obtained by ANOVA and the Tukey post-hoc test (P < .01). The correlation test and the paired t test (P < .05) were used to compare the computer simulation with the mechanical experiment. The computer simulation accurately predicted the experimentally determined mechanical behavior of tear drop loops of different heights and should be considered an alternative for designing orthodontic appliances before treatment.
Temporary Thermocouple Attachment for Thermal/Vacuum Testing at Non-Extreme Temperatures
NASA Technical Reports Server (NTRS)
Ungar, Eugene K.; Wright, Sarah E.
2016-01-01
Post-test examination and data analysis that followed a two week long vacuum test showed that numerous self-stick thermocouples became detached from the test article. The thermocouples were reattached with thermally conductive epoxy and the test was repeated to obtain the required data. Because the thermocouple detachment resulted in significant expense and rework, it was decided to investigate the temporary attachment methods used around NASA and to perform a test to assess their efficacy. The present work describes the original test and the analysis that showed that the thermocouples had become detached, temporary thermocouple attachment methods assessed in the retest and in the thermocouple attachment test, and makes a recommendation for attachment methods for future tests.
Thermal measurement of brake pad lining surfaces during the braking process
NASA Astrophysics Data System (ADS)
Piątkowski, Tadeusz; Polakowski, Henryk; Kastek, Mariusz; Baranowski, Pawel; Damaziak, Krzysztof; Małachowski, Jerzy; Mazurkiewicz, Łukasz
2012-06-01
This paper presents the test campaign concept and definition and the analysis of the recorded measurements. One of the most important systems in cars and trucks are brakes. The braking temperature on a lining surface can rise above 500°C. This shows how linings requirements are so strict and, what is more, continuously rising. Besides experimental tests, very supportive method for investigating processes which occur on the brake pad linings are numerical analyses. Experimental tests were conducted on the test machine called IL-68. The main component of IL-68 is so called frictional unit, which consists of: rotational head, which convey a shaft torque and where counter samples are placed and translational head, where samples of coatings are placed and pressed against counter samples. Due to the high rotational speeds and thus the rapid changes in temperature field, the infrared camera was used for testing. The paper presents results of analysis registered thermograms during the tests with different conditions. Furthermore, based on this testing machine, the numerical model was developed. In order to avoid resource demanding analyses only the frictional unit (described above) was taken into consideration. Firstly the geometrical model was performed thanks to CAD techniques, which in the next stage was a base for developing the finite element model. Material properties and boundary conditions exactly correspond to experimental tests. Computations were performed using a dynamic LS-Dyna code where heat generation was estimated assuming full (100%) conversion of mechanical work done by friction forces. Paper presents the results of dynamic thermomechanical analysis too and these results were compared with laboratory tests.
Analysis of longitudinal "time series" data in toxicology.
Cox, C; Cory-Slechta, D A
1987-02-01
Studies focusing on chronic toxicity or on the time course of toxicant effect often involve repeated measurements or longitudinal observations of endpoints of interest. Experimental design considerations frequently necessitate between-group comparisons of the resulting trends. Typically, procedures such as the repeated-measures analysis of variance have been used for statistical analysis, even though the required assumptions may not be satisfied in some circumstances. This paper describes an alternative analytical approach which summarizes curvilinear trends by fitting cubic orthogonal polynomials to individual profiles of effect. The resulting regression coefficients serve as quantitative descriptors which can be subjected to group significance testing. Randomization tests based on medians are proposed to provide a comparison of treatment and control groups. Examples from the behavioral toxicology literature are considered, and the results are compared to more traditional approaches, such as repeated-measures analysis of variance.
[The Scope, Quality and Safety Requirements of Drug Abuse Testing].
Küme, Tuncay; Karakükcü, Çiğdem; Pınar, Aslı; Coşkunol, Hakan
2017-01-01
The aim of this review is to inform about the scopes and requirements of drug abuse testing. Drug abuse testing is one of the tools for determination of drug use. It must fulfill the quality and safety requirements in judgmental legal and administrative decisions. Drug abuse testing must fulfill some requirements like selection of the appropriate test matrix, appropriate screening test panel, sampling in detection window, patient consent, identification of the donor, appropriate collection site, sample collection with observation, identification and control of the sample, specimen custody chain in preanalytical phase; analysis in authorized laboratories, specimen validity tests, reliable testing METHODS, strict quality control, two-step analysis in analytical phase; storage of the split specimen, confirmation of the split specimen in the objection, result custody chain, appropriate cut-off concentration, the appropriate interpretation of the result in postanalytical phase. The workflow and analytical processes of drug abuse testing are explained in last regulation of the Department of Medical Laboratory Services, Ministry of Health in Turkey. The clinical physicians have to know and apply the quality and safety requirements in drug abuse testing according to last regulations in Turkey.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zauderer, B.; Fleming, E.S.
1991-08-30
This work contains to the final report of the demonstration of an advanced cyclone coal combustor. Titles include: Chronological Description of the Clean Coal Project Tests,'' Statistical Analysis of Operating Data for the Coal Tech Combustor,'' Photographic History of the Project,'' Results of Slag Analysis by PA DER Module 1 Procedure,'' Properties of the Coals Limestone Used in the Test Effort,'' Results of the Solid Waste Sampling Performed on the Coal Tech Combustor by an Independent Contractor During the February 1990 Tests.'' (VC)
Dynamic Modeling and Testing of MSRR-1 for Use in Microgravity Environments Analysis
NASA Technical Reports Server (NTRS)
Gattis, Christy; LaVerde, Bruce; Howell, Mike; Phelps, Lisa H. (Technical Monitor)
2001-01-01
Delicate microgravity science is unlikely to succeed on the International Space Station if vibratory and transient disturbers corrupt the environment. An analytical approach to compute the on-orbit acceleration environment at science experiment locations within a standard payload rack resulting from these disturbers is presented. This approach has been grounded by correlation and comparison to test verified transfer functions. The method combines the results of finite element and statistical energy analysis using tested damping and modal characteristics to provide a reasonable approximation of the total root-mean-square (RMS) acceleration spectra at the interface to microgravity science experiment hardware.
Testing for intracycle determinism in pseudoperiodic time series.
Coelho, Mara C S; Mendes, Eduardo M A M; Aguirre, Luis A
2008-06-01
A determinism test is proposed based on the well-known method of the surrogate data. Assuming predictability to be a signature of determinism, the proposed method checks for intracycle (e.g., short-term) determinism in the pseudoperiodic time series for which standard methods of surrogate analysis do not apply. The approach presented is composed of two steps. First, the data are preprocessed to reduce the effects of seasonal and trend components. Second, standard tests of surrogate analysis can then be used. The determinism test is applied to simulated and experimental pseudoperiodic time series and the results show the applicability of the proposed test.
Low-speed Aerodynamic Investigations of a Hybrid Wing Body Configuration
NASA Technical Reports Server (NTRS)
Vicroy, Dan D.; Gatlin, Gregory M.; Jenkins, Luther N.; Murphy, Patrick C.; Carter, Melissa B.
2014-01-01
Two low-speed static wind tunnel tests and a water tunnel static and dynamic forced-motion test have been conducted on a hybrid wing-body (HWB) twinjet configuration. These tests, in addition to computational fluid dynamics (CFD) analysis, have provided a comprehensive dataset of the low-speed aerodynamic characteristics of this nonproprietary configuration. In addition to force and moment measurements, the tests included surface pressures, flow visualization, and off-body particle image velocimetry measurements. This paper will summarize the results of these tests and highlight the data that is available for code comparison or additional analysis.
Identification and detection of anomalies through SSME data analysis
NASA Technical Reports Server (NTRS)
Pereira, Lisa; Ali, Moonis
1990-01-01
The goal of the ongoing research described in this paper is to analyze real-time ground test data in order to identify patterns associated with the anomalous engine behavior, and on the basis of this analysis to develop an expert system which detects anomalous engine behavior in the early stages of fault development. A prototype of the expert system has been developed and tested on the high frequency data of two SSME tests, namely Test #901-0516 and Test #904-044. The comparison of our results with the post-test analyses indicates that the expert system detected the presence of the anomalies in a significantly early stage of fault development.
Experiments with Test Case Generation and Runtime Analysis
NASA Technical Reports Server (NTRS)
Artho, Cyrille; Drusinsky, Doron; Goldberg, Allen; Havelund, Klaus; Lowry, Mike; Pasareanu, Corina; Rosu, Grigore; Visser, Willem; Koga, Dennis (Technical Monitor)
2003-01-01
Software testing is typically an ad hoc process where human testers manually write many test inputs and expected test results, perhaps automating their execution in a regression suite. This process is cumbersome and costly. This paper reports preliminary results on an approach to further automate this process. The approach consists of combining automated test case generation based on systematically exploring the program's input domain, with runtime analysis, where execution traces are monitored and verified against temporal logic specifications, or analyzed using advanced algorithms for detecting concurrency errors such as data races and deadlocks. The approach suggests to generate specifications dynamically per input instance rather than statically once-and-for-all. The paper describes experiments with variants of this approach in the context of two examples, a planetary rover controller and a space craft fault protection system.
Heintze, Siegward D
2007-01-01
An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both topics, about 80% of the studies revealed that there was no correlation between the two methods. For the correlation quantitative marginal analysis/clinical outcome, data were compared to the clinical outcome of 11 selected clinical studies. In only 2 out of the 11 studies (18%) did the clinical outcome match the prognosis based on the laboratory tests; the remaining studies did not show any correlation. When pooling data on 20 adhesive systems, no correlation was found between the percentage of continuous margin of restorations placed in extracted premolars and the percentage of teeth that showed no retention loss in clinical studies, no discoloured margins, acceptable margins, or absence of secondary caries. With regard to the correlation of dye penetration and clinical studies, no sufficient number of studies was found that matched the inclusion criteria. However, literature data suggest that there is no correlation between microleakage data as measured in the laboratory and clinical parameters. The results of bond strength tests did not correlate with laboratory tests that evaluated the marginal seal of restorations such as microleakage or gap analysis. The quantitative marginal analysis of Class V fillings in the laboratory was unable to predict the performance of the same materials in vivo. Therefore, microleakage tests or the quantitative marginal analysis should be abandoned and research should focus on laboratory tests that are validated with regard to their ability to satisfactorily predict the clinical performance of restorative materials.
Estimating Full IM240 Emissions from Partial Test Results: Evidence from Arizona.
Ando, Amy W; Harrington, Winston; McConnell, Virginia
1999-10-01
The expense and inconvenience of enhanced-vehicle-emissions testing using the full 240-second dynamometer test has led states to search for ways to shorten the test process. In fact, all states that currently use the IM240 allow some type of fast-pass, usually as early in the test as second 31, and Arizona has allowed vehicles to fast-fail after second 93. While these shorter tests save states millions of dollars in inspection lanes and driver costs, there is a loss of information since test results are no longer comparable across vehicles. This paper presents a methodology for estimating full 240-second results from partial-test results for three pollutants: HC, CO, and NO x . If states can convert all tests to consistent IM240 readings, they will be able to better characterize fleet emissions and to evaluate the impact of inspection and maintenance and other programs on emissions over time. Using a random sample of vehicles in Arizona which received full 240-second tests, we use regression analysis to estimate the relationship between emissions at second 240 and emissions at earlier seconds in the test. We examine the influence of other variables such as age, model-year group, and the pollution level itself on this relationship. We also use the estimated coefficients in several applications. First, we try to shed light on the frequent assertion that the results of the dynamometer test provide guidance for vehicle repair of failing vehicles. Using a probit analysis, we find that the probability that a failing vehicle will pass the test on the first retest is greater the longer the test has progressed. Second, we test the accuracy of our estimates for forecasting fleet emissions from partial-test emissions results in Arizona. We find forecasted fleet average emissions to be very close to the actual fleet averages for light-duty vehicles, but not quite as good for trucks, particularly when NO x emissions are forecast.
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi; Leyland, Jane
1991-01-01
The effects of open loop higher harmonic control (HHC) on rotor hub loads, performance, and push rod loads of a Sikorsky S-76 helicopter rotor at high airspeeds (up to 200 knots) and moderate lift (10,000 lbs) were studied analytically. The analysis was performed as part of a wind tunnel pre-test prediction and preparation procedure, as well as to provide analytical results for post-test correlation efforts. The test associated with this study is to be concluded in the 40- by 80-Foot Wind Tunnel of the National Full-Scale Aerodynamics Complex (NFAC) at the NASA Ames Research Center. The results from this analytical study show that benefits from HHC can be achieved at high airspeeds. These results clear the way for conducting (with the requirement of safe pushrod loads) an open loop HHC test a high airspeeds in the 40- by 80-Foot Wind Tunnel using an S-76 rotor as the test article.
Small Wind Research Turbine: Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corbus, D.; Meadors, M.
2005-10-01
The Small Wind Research Turbine (SWRT) project was initiated to provide reliable test data for model validation of furling wind turbines and to help understand small wind turbine loads. This report will familiarize the user with the scope of the SWRT test and support the use of these data. In addition to describing all the testing details and results, the report presents an analysis of the test data and compares the SWRT test data to simulation results from the FAST aeroelastic simulation model.
Significant issues in proof testing: A critical appraisal
NASA Technical Reports Server (NTRS)
Chell, G. G.; Mcclung, R. C.; Russell, D. A.; Chang, K. J.; Donnelly, B.
1994-01-01
Issues which impact on the interpretation and quantification of proof test benefits are reviewed. The importance of each issue in contributing to the extra quality assurance conferred by proof testing components is discussed, particularly with respect to the application of advanced fracture mechanics concepts to enhance the flaw screening capability of a proof test analysis. Items covered include the role in proof testing of elastic-plastic fracture mechanics, ductile instability analysis, deterministic versus probabilistic analysis, single versus multiple cycle proof testing, and non-destructive examination (NDE). The effects of proof testing on subsequent service life are reviewed, particularly with regard to stress redistribution and changes in fracture behavior resulting from the overload. The importance of proof test conditions are also addressed, covering aspects related to test temperature, simulation of service environments, test media and the application of real-time NDE. The role of each issue in a proof test methodology is assessed with respect to its ability to: promote proof test practice to a state-of-the-art; aid optimization of proof test design; and increase awareness and understanding of outstanding issues.
NASA Technical Reports Server (NTRS)
Perez, Jose G.; Parks, Russel A.; Lazor, Daniel R.
2012-01-01
The slosh dynamics of propellant tanks can be represented by an equivalent pendulum-mass mechanical model. The parameters of this equivalent model, identified as slosh model parameters, are slosh mass, slosh mass center of gravity, slosh frequency, and smooth-wall damping. They can be obtained by both analysis and testing for discrete fill heights. Anti-slosh baffles are usually needed in propellant tanks to control the movement of the fluid inside the tank. Lateral slosh testing, involving both random testing and free-decay testing, are performed to validate the slosh model parameters and the damping added to the fluid by the anti-slosh baffles. Traditional modal analysis procedures are used to extract the parameters from the experimental data. Test setup of sub-scale test articles of cylindrical and spherical shapes will be described. A comparison between experimental results and analysis will be presented.
NASA Technical Reports Server (NTRS)
Jordan, F. L., Jr.
1980-01-01
As part of basic research to improve aerial applications technology, methods were developed at the Langley Vortex Research Facility to simulate and measure deposition patterns of aerially-applied sprays and granular materials by means of tests with small-scale models of agricultural aircraft and dynamically-scaled test particles. Interactions between the aircraft wake and the dispersed particles are being studied with the objective of modifying wake characteristics and dispersal techniques to increase swath width, improve deposition pattern uniformity, and minimize drift. The particle scaling analysis, test methods for particle dispersal from the model aircraft, visualization of particle trajectories, and measurement and computer analysis of test deposition patterns are described. An experimental validation of the scaling analysis and test results that indicate improved control of chemical drift by use of winglets are presented to demonstrate test methods.
NASA Technical Reports Server (NTRS)
Cosentino, Gary B.
2007-01-01
Several examples from the past decade of success stories involving the design and flight test of three true X-planes will be described: in particular, X-plane design techniques that relied heavily upon computational fluid dynamics (CFD). Three specific examples chosen from the author s personal experience are presented: the X-36 Tailless Fighter Agility Research Aircraft, the X-45A Unmanned Combat Air Vehicle, and, most recently, the X-48B Blended Wing Body Demonstrator Aircraft. An overview will be presented of the uses of CFD analysis, comparisons and contrasts with wind tunnel testing, and information derived from the CFD analysis that directly related to successful flight test. Some lessons learned on the proper application, and misapplication, of CFD are illustrated. Finally, some highlights of the flight-test results of the three example X-planes will be presented. This overview paper will discuss some of the author s experience with taking an aircraft shape from early concept and three-dimensional modeling through CFD analysis, wind tunnel testing, further refined CFD analysis, and, finally, flight. An overview of the key roles in which CFD plays well during this process, and some other roles in which it does not, are discussed. How wind tunnel testing complements, calibrates, and verifies CFD analysis is also covered. Lessons learned on where CFD results can be misleading are also given. Strengths and weaknesses of the various types of flow solvers, including panel methods, Euler, and Navier-Stokes techniques, are discussed. The paper concludes with the three specific examples, including some flight test video footage of the X-36, the X-45A, and the X-48B.
NASA Technical Reports Server (NTRS)
Cosentino, Gary B.
2007-01-01
Several examples from the past decade of success stories involving the design and ight test of three true X-planes will be described: in particular, X-plane design techniques that relied heavily upon computational fluid dynamics (CFD). Three specific examples chosen from the authors personal experience are presented: the X-36 Tailless Fighter Agility Research Aircraft, the X-45A Unmanned Combat Air Vehicle, and, most recently, the X-48B Blended Wing Body Demonstrator Aircraft. An overview will be presented of the uses of CFD analysis, comparisons and contrasts with wind tunnel testing, and information derived from the CFD analysis that directly related to successful flight test. Some lessons learned on the proper application, and misapplication, of CFD are illustrated. Finally, some highlights of the flight-test results of the three example X-planes will be presented. This overview paper will discuss some of the authors experience with taking an aircraft shape from early concept and three-dimensional modeling through CFD analysis, wind tunnel testing, further re ned CFD analysis, and, finally, flight. An overview of the key roles in which CFD plays well during this process, and some other roles in which it does not, are discussed. How wind tunnel testing complements, calibrates, and verifies CFD analysis is also covered. Lessons learned on where CFD results can be misleading are also given. Strengths and weaknesses of the various types of ow solvers, including panel methods, Euler, and Navier-Stokes techniques, are discussed. The paper concludes with the three specific examples, including some flight test video footage of the X-36, the X-45A, and the X-48B.
RERTR-10 Irradiation Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. M. Perez
2011-05-01
The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-10 was designed to further test the effectiveness of modified fuel/clad interfaces in monolithic fuel plates. The experiment was conducted in two campaigns: RERTR-10A and RERTR-10B. The fuel plates tested in RERTR-10A were all fabricated by Hot Isostatic Pressing (HIP) and were designed to evaluate the effect of various Si levels in the interlayer and the thickness of the Zr interlayer (0.001”) using 0.010” and 0.020” nominal foil thicknesses. The fuel plates in RERTR-10B were fabricated by Friction Bonding (FB) with two different thickness Si layers and Nb and Zrmore » diffusion barriers.1 The following report summarizes the life of the RERTR-10A/B experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.« less
Design and test of a 2m x 4m DART system
NASA Technical Reports Server (NTRS)
Tolomeo, J.; Loane, J.; Cross, G.; Tenerelli, D.; Sable, B.; Decker, T.; Nelson, T.; Joseph, B.; Windes, C.; Kokawa, D.;
2003-01-01
A 2 meter by 4 meter DART (dual anamorphic reflector telescope) system has been designed and fabricated using thin stretched mesh reflectors. This report documents the structural configuration, test preparation, test results, and analysis correlation.
Drug and Alcohol Testing Results - 1995 Annual Report
DOT National Transportation Integrated Search
1997-03-01
The Report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1995. The report covers testing for alcohol and the following drug types: marijuana (THC), cocaine, phencyclidin...
Propfan test assessment testbed aircraft flutter model test report
NASA Technical Reports Server (NTRS)
Jenness, C. M. J.
1987-01-01
The PropFan Test Assessment (PTA) program includes flight tests of a propfan power plant mounted on the left wind of a modified Gulfstream II testbed aircraft. A static balance boom is mounted on the right wing tip for lateral balance. Flutter analyses indicate that these installations reduce the wing flutter stabilizing speed and that torsional stiffening and the installation of a flutter stabilizing tip boom are required on the left wing for adequate flutter safety margins. Wind tunnel tests of a 1/9th scale high speed flutter model of the testbed aircraft were conducted. The test program included the design, fabrication, and testing of the flutter model and the correlation of the flutter test data with analysis results. Excellent correlations with the test data were achieved in posttest flutter analysis using actual model properties. It was concluded that the flutter analysis method used was capable of accurate flutter predictions for both the (symmetric) twin propfan configuration and the (unsymmetric) single propfan configuration. The flutter analysis also revealed that the differences between the tested model configurations and the current aircraft design caused the (scaled) model flutter speed to be significantly higher than that of the aircraft, at least for the single propfan configuration without a flutter boom. Verification of the aircraft final design should, therefore, be based on flutter predictions made with the test validated analysis methods.
NASA Technical Reports Server (NTRS)
Gong, Chester; Wu, Minghong G.; Santiago, Confesor
2016-01-01
The Unmanned Aircraft Systems Integration in the National Airspace System project, or UAS Integration in the NAS, aims to reduce technical barriers related to safety and operational challenges associated with enabling routine UAS access to the NAS. The UAS Integration in the NAS Project conducted a flight test activity, referred to as Flight Test 3 (FT3), involving several Detect-and-Avoid (DAA) research prototype systems between June 15, 2015 and August 12, 2015 at the Armstrong Flight Research Center (AFRC). This report documents the flight testing and analysis results for the NASA Ames-developed JADEM-Autoresolver DAA system, referred to as 'Autoresolver' herein. Four flight test days (June 17, 18, 22, and July 22) were dedicated to Autoresolver testing. The objectives of this test were as follows: 1. Validate CPA prediction accuracy and detect-and-avoid (DAA, formerly known as self-separation) alerting logic in realistic flight conditions. 2. Validate DAA trajectory model including maneuvers. 3. Evaluate TCAS/DAA interoperability. 4. Inform final Minimum Operating Performance Standards (MOPS). Flight test scenarios were designed to collect data to directly address the objectives 1-3. Objective 4, inform final MOPS, was a general objective applicable to the UAS in the NAS project as a whole, of which flight test is a subset. This report presents analysis results completed in support of the UAS in the NAS project FT3 data review conducted on October 20, 2015. Due to time constraints and, to a lesser extent, TCAS data collection issues, objective 3 was not evaluated in this analysis.
Daigger, Glen T; Siczka, John S; Smith, Thomas F; Frank, David A; McCorquodale, J A
The performance characteristics of relatively shallow (3.3 and 3.7 m sidewater depth in 30.5 m diameter) activated sludge secondary clarifiers were extensively evaluated during a 2-year testing program at the City of Akron Water Reclamation Facility (WRF), Ohio, USA. Testing included hydraulic and solids loading stress tests, and measurement of sludge characteristics (zone settling velocity (ZSV), dispersed and flocculated total suspended solids), and the results were used to calibrate computational fluid dynamic (CFD) models of the various clarifiers tested. The results demonstrated that good performance could be sustained at surface overflow rates in excess of 3 m/h, as long as the clarifier influent mixed liquor suspended solids (MLSS) concentration was controlled to below critical values. The limiting solids loading rate (SLR) was significantly lower than the value predicted by conventional solids flux analysis based on the measured ZSV/MLSS relationship. CFD analysis suggested that this resulted because mixed liquor entering the clarifier was being directed into the settled sludge blanket, diluting it and also creating a 'thin' concentration sludge blanket that overlays the thicker concentration sludge blanket typically expected. These results indicate the need to determine the allowable SLR for shallow clarifiers using approaches other than traditional solids flux analysis. A combination of actual testing and CFD analyses are demonstrated here to be effective in doing so.
Heave-pitch-roll analysis and testing of air cushion landing systems
NASA Technical Reports Server (NTRS)
Boghani, A. B.; Captain, K. M.; Wormley, D. N.
1978-01-01
The analytical tools (analysis and computer simulation) needed to explain and predict the dynamic operation of air cushion landing systems (ACLS) is described. The following tasks were performed: the development of improved analytical models for the fan and the trunk; formulation of a heave pitch roll analysis for the complete ACLS; development of a general purpose computer simulation to evaluate landing and taxi performance of an ACLS equipped aircraft; and the verification and refinement of the analysis by comparison with test data obtained through lab testing of a prototype cushion. Demonstration of simulation capabilities through typical landing and taxi simulation of an ACLS aircraft are given. Initial results show that fan dynamics have a major effect on system performance. Comparison with lab test data (zero forward speed) indicates that the analysis can predict most of the key static and dynamic parameters (pressure, deflection, acceleration, etc.) within a margin of a 10 to 25 percent.
Faying Surface Lubrication Effects on Nut Factors
NASA Technical Reports Server (NTRS)
Taylor, Deneen M.; Morrison, Raymond F.
2006-01-01
Bolted joint analysis typically is performed using nut factors derived from textbooks and procedures from program requirement documents. Joint specific testing was performed for a critical International Space Station (ISS) joint. Test results indicate that for some configurations the nut factor may be significantly different than accepted textbook values. This paper presents results of joint specific testing to aid in determining if joint specific testing should be performed to insure required preloads are obtained.
Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study
Halambek, Jasna; Maldini, Krešimir; Balog, Martin; Križik, Peter; Schauperl, Zdravko; Ćatić, Amir
2016-01-01
Background The innovative titanium-magnesium composite (Ti-Mg) was produced by powder metallurgy (P/M) method and is characterized in terms of corrosion behavior. Material and methods Two groups of experimental material, 1 mass% (Ti-1Mg) and 2 mass% (Ti-2Mg) of magnesium in titanium matrix, were tested and compared to commercially pure titanium (CP Ti). Immersion test and chemical analysis of four solutions: artificial saliva; artificial saliva pH 4; artificial saliva with fluoride and Hank balanced salt solution were performed after 42 days of immersion, using inductively coupled plasma mass spectrometry (ICP-MS) to detect the amount of released titanium ions (Ti). SEM and EDS analysis were used for surface characterization. Results The difference between the results from different test solutions was assessed by ANOVA and Newman-Keuls test at p<0.05. The influence of predictor variables was found by multiple regression analysis. The results of the present study revealed a low corrosion rate of titanium from the experimental Ti-Mg group. Up to 46 and 23 times lower dissolution of Ti from Ti-1Mg and Ti-2Mg, respectively was observed compared to the control group. Among the tested solutions, artificial saliva with fluorides exhibited the highest corrosion effect on all specimens tested. SEM micrographs showed preserved dual phase surface structure and EDS analysis suggested a favorable surface bioactivity. Conclusion In conclusion, Ti-Mg produced by P/M as a material with better corrosion properties when compared to CP Ti is suggested. PMID:27688425
Performance of concrete members subjected to large hydrocarbon pool fires
Zwiers, Renata I.; Morgan, Bruce J.
1989-01-01
The authors discuss an investigation to determine analytically if the performance of concrete beams and columns in a hydrocarbon pool test fire would differ significantly from their performance in a standard test fire. The investigation consisted of a finite element analysis to obtain temperature distributions in typical cross sections, a comparison of the resulting temperature distribution in the cross section, and a strength analysis of a beam based on temperature distribution data. Results of the investigation are reported.
NASA Astrophysics Data System (ADS)
Mushlihuddin, R.; Nurafifah; Irvan
2018-01-01
The student’s low ability in mathematics problem solving proved to the less effective of a learning process in the classroom. Effective learning was a learning that affects student’s math skills, one of which is problem-solving abilities. Problem-solving capability consisted of several stages: understanding the problem, planning the settlement, solving the problem as planned, re-examining the procedure and the outcome. The purpose of this research was to know: (1) was there any influence of PBL model in improving ability Problem solving of student math in a subject of vector analysis?; (2) was the PBL model effective in improving students’ mathematical problem-solving skills in vector analysis courses? This research was a quasi-experiment research. The data analysis techniques performed from the test stages of data description, a prerequisite test is the normality test, and hypothesis test using the ANCOVA test and Gain test. The results showed that: (1) there was an influence of PBL model in improving students’ math problem-solving abilities in vector analysis courses; (2) the PBL model was effective in improving students’ problem-solving skills in vector analysis courses with a medium category.
Integrated Vehicle Ground Vibration Testing in Support of Launch Vehicle Loads and Controls Analysis
NASA Technical Reports Server (NTRS)
Tuma, Margaret L.; Chenevert, Donald J.
2009-01-01
NASA has conducted dynamic tests on each major launch vehicle during the past 45 years. Each test provided invaluable data to correlate and correct analytical models. GVTs result in hardware changes to Saturn and Space Shuttle, ensuring crew and vehicle safety. Ares I IVGT will provide test data such as natural frequencies, mode shapes, and damping to support successful Ares I flights. Testing will support controls analysis by providing data to reduce model uncertainty. Value of testing proven by past launch vehicle successes and failures. Performing dynamic testing on Ares vehicles will provide confidence that the launch vehicles will be safe and successful in their missions.
Comparison ofdvanced turboprop interior noise control ground and flight test data
NASA Technical Reports Server (NTRS)
Simpson, Myles A.; Tran, Boi N.
1992-01-01
Interior noise ground tests conducted on a DC-9 aircraft test section are described. The objectives were to study ground test and analysis techniques for evaluating the effectiveness of interior noise control treatments for advanced turboprop aircraft, and to study the sensitivity of the ground test results to changes in various test conditions. Noise and vibration measurements were conducted under simulated advanced turboprop excitation, for two interior noise control treatment configurations. These ground measurement results were compared with results of earlier UHB (Ultra High Bypass) Demonstrator flight sts with comparable interior treatment configurations. The Demonstrator is an MD-80 test aircraft with the left JT8D engine replaced with a prototype UHB advanced turboprop engine.
Comparison ofdvanced turboprop interior noise control ground and flight test data
NASA Astrophysics Data System (ADS)
Simpson, Myles A.; Tran, Boi N.
Interior noise ground tests conducted on a DC-9 aircraft test section are described. The objectives were to study ground test and analysis techniques for evaluating the effectiveness of interior noise control treatments for advanced turboprop aircraft, and to study the sensitivity of the ground test results to changes in various test conditions. Noise and vibration measurements were conducted under simulated advanced turboprop excitation, for two interior noise control treatment configurations. These ground measurement results were compared with results of earlier UHB (Ultra High Bypass) Demonstrator flight sts with comparable interior treatment configurations. The Demonstrator is an MD-80 test aircraft with the left JT8D engine replaced with a prototype UHB advanced turboprop engine.
Comparison of two computer codes for crack growth analysis: NASCRAC Versus NASA/FLAGRO
NASA Technical Reports Server (NTRS)
Stallworth, R.; Meyers, C. A.; Stinson, H. C.
1989-01-01
Results are presented from the comparison study of two computer codes for crack growth analysis - NASCRAC and NASA/FLAGRO. The two computer codes gave compatible conservative results when the part through crack analysis solutions were analyzed versus experimental test data. Results showed good correlation between the codes for the through crack at a lug solution. For the through crack at a lug solution, NASA/FLAGRO gave the most conservative results.
Tuffaha, Haitham W; Mitchell, Andrew; Ward, Robyn L; Connelly, Luke; Butler, James R G; Norris, Sarah; Scuffham, Paul A
2018-01-04
PurposeTo evaluate the cost-effectiveness of BRCA testing in women with breast cancer, and cascade testing in family members of BRCA mutation carriers.MethodsA cost-effectiveness analysis was conducted using a cohort Markov model from a health-payer perspective. The model estimated the long-term benefits and costs of testing women with breast cancer who had at least a 10% pretest BRCA mutation probability, and the cascade testing of first- and second-degree relatives of women who test positive.ResultsCompared with no testing, BRCA testing of affected women resulted in an incremental cost per quality-adjusted life-year (QALY) gained of AU$18,900 (incremental cost AU$1,880; incremental QALY gain 0.10) with reductions of 0.04 breast and 0.01 ovarian cancer events. Testing affected women and cascade testing of family members resulted in an incremental cost per QALY gained of AU$9,500 compared with testing affected women only (incremental cost AU$665; incremental QALY gain 0.07) with additional reductions of 0.06 breast and 0.01 ovarian cancer events.ConclusionBRCA testing in women with breast cancer is cost-effective and is associated with reduced risk of cancer and improved survival. Extending testing to cover family members of affected women who test positive improves cost-effectiveness beyond restricting testing to affected women only.GENETICS in MEDICINE advance online publication, 4 January 2018; doi:10.1038/gim.2017.231.
Comparison of analysis and flight test data for a drone aircraft with active flutter suppression
NASA Technical Reports Server (NTRS)
Newsom, J. R.; Pototzky, A. S.
1981-01-01
A drone aircraft equipped with an active flutter suppression system is considered with emphasis on the comparison of modal dampings and frequencies as a function of Mach number. Results are presented for both symmetric and antisymmetric motion with flutter suppression off. Only symmetric results are given for flutter suppression on. Frequency response functions of the vehicle are presented from both flight test data and analysis. The analysis correlation is improved by using an empirical aerodynamic correction factor which is proportional to the ratio of experimental to analytical steady-state lift curve slope. The mathematical models are included and existing analytical techniques are described as well as an alternative analytical technique for obtaining closed-loop results.
Integrated Data Collection Analysis (IDCA) Program - AN and Bullseye Smokeless Powder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN) mixed with Bullseye® smokeless powder (Gunpowder). The participants found the AN/Gunpowder to: 1) have a range of sensitivity to impact, comparable to or less than RDX, 2) be fairly insensitive to friction as measured by BAM and ABL, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) have thermal sensitivity aboutmore » the same as PETN and Gunpowder. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed when developing safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods. Note, however, the test procedures differ among the laboratories. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent. Keywords: Small-scale safety testing, proficiency test, impact-, friction-, spark discharge-, thermal testing, round-robin test, safety testing protocols, HME, RDX, potassium perchlorate, potassium chlorate, sodium chlorate, sugar, dodecane, PETN, carbon, ammonium nitrate, Gunpowder, Bullseye® smokeless powder.« less
Airfoil Vibration Dampers program
NASA Technical Reports Server (NTRS)
Cook, Robert M.
1991-01-01
The Airfoil Vibration Damper program has consisted of an analysis phase and a testing phase. During the analysis phase, a state-of-the-art computer code was developed, which can be used to guide designers in the placement and sizing of friction dampers. The use of this computer code was demonstrated by performing representative analyses on turbine blades from the High Pressure Oxidizer Turbopump (HPOTP) and High Pressure Fuel Turbopump (HPFTP) of the Space Shuttle Main Engine (SSME). The testing phase of the program consisted of performing friction damping tests on two different cantilever beams. Data from these tests provided an empirical check on the accuracy of the computer code developed in the analysis phase. Results of the analysis and testing showed that the computer code can accurately predict the performance of friction dampers. In addition, a valuable set of friction damping data was generated, which can be used to aid in the design of friction dampers, as well as provide benchmark test cases for future code developers.
Contribution to interplay between a delamination test and a sensory analysis of mid-range lipsticks.
Richard, C; Tillé-Salmon, B; Mofid, Y
2016-02-01
Lipstick is currently one of the most sold products of cosmetics industry, and the competition between the various manufacturers is significant. Customers mainly seek products with high spreadability, especially long-lasting or long wear on the lips. Evaluation tests of cosmetics are usually performed by sensory analysis. This can then represent a considerable cost. The object of this study was to develop a fast and simple test of delamination (objective method with calibrated instruments) and to interplay the obtained results with those of a discriminative sensory analysis (subjective method) in order to show the relevance of the instrumental test. Three mid-range lipsticks were randomly chosen and were tested. They were made of compositions as described by the International Nomenclature of Cosmetic Ingredients (INCI). Instrumental characterization was performed by texture profile analysis and by a special delamination test. The sensory analysis was voluntarily conducted with an untrained panel as blind test to confirm or reverse the possible interplay. The two approaches or methods gave the same type of classification. The high-fat lipstick had the worst behaviour with the delamination test and the worst notation of the intensity of descriptors with the sensory analysis. There is a high correlation between the sensory analysis and the instrumental measurements in this study. The delamination test carried out should permit to quickly determine the lasting (screening test) and in consequence optimize the basic formula of lipsticks. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Forghani, Masoomeh; Ghanbari Hashem Abadi, Bahram Ali
2016-06-01
The aim of the present study was to evaluate the effect of group psychotherapy with transactional analysis (TA) approach on emotional intelligence (EI), executive functions and substance dependency among drug-addicts at rehabilitation centers in Mashhad city, Iran, in 2013. In this quasi-experimental study with pretest, posttest, case- control stages, 30 patients were selected from a rehabilitation center and randomly divided into two groups. The case group received 12 sessions of group psychotherapy with transactional analysis approach. Then the effects of independent variable (group psychotherapy with TA approach) on EI, executive function and drug dependency were assessed. The Bar-on test was used for EI, Stroop test for measuring executive function and morphine test, meth-amphetamines and B2 test for evaluating drug dependency. Data were analyzed using multifactorial covariance analysis, Levenes' analysis, MANCOVA, t-student and Pearson correlation coefficient tests t with SPSS software. Our results showed that group psychotherapy with the TA approach was effective in improving EI, executive functions and decreasing drug dependency (P < 0.05). The result of this study showed that group psychotherapy with TA approach has significant effects on addicts and prevents addiction recurrence by improving the coping capabilities and some mental functions of the subjects. However, there are some limitations regarding this study including follow-up duration and sample size.
An Analysis of Model Scale Data Transformation to Full Scale Flight Using Chevron Nozzles
NASA Technical Reports Server (NTRS)
Brown, Clifford; Bridges, James
2003-01-01
Ground-based model scale aeroacoustic data is frequently used to predict the results of flight tests while saving time and money. The value of a model scale test is therefore dependent on how well the data can be transformed to the full scale conditions. In the spring of 2000, a model scale test was conducted to prove the value of chevron nozzles as a noise reduction device for turbojet applications. The chevron nozzle reduced noise by 2 EPNdB at an engine pressure ratio of 2.3 compared to that of the standard conic nozzle. This result led to a full scale flyover test in the spring of 2001 to verify these results. The flyover test confirmed the 2 EPNdB reduction predicted by the model scale test one year earlier. However, further analysis of the data revealed that the spectra and directivity, both on an OASPL and PNL basis, do not agree in either shape or absolute level. This paper explores these differences in an effort to improve the data transformation from model scale to full scale.
NASA Technical Reports Server (NTRS)
Strout, F. G.
1976-01-01
A JT8D-17 turbofan engine was tested in the NASA-Ames 40- by 80-foot wind tunnel to determine flight effects on jet and fan noise. Baseline, quiet nacelle with 20-lobe ejector/suppressor, and internal mixer configurations were tested over a range of engine power settings and tunnel velocities. Flight effects derived from the 40- by 80-foot wind tunnel test are compared with 727/JT8D flight test data and with model data obtained in a smaller wind tunnel. Procedures are defined for measuring noise data in a wind tunnel relatively near the sources and analyzing the results to obtain far-field flight effects. Wind tunnel and 727 flight test noise results compare favorably for both the baseline and quiet nacelle configurations. Two reports are provided, including a comprehensive version with extensive test results and analysis and the subject summary version that emphasizes data analysis and program finding.
NASA Astrophysics Data System (ADS)
Anggraini, L.; Sugeng
2018-05-01
This research discusses the testing and analysis of cracking Aluminum (Al) material. Al as a handle lever was used for a braking device on a motor vehicle. Cracking of handle lever due to the part content of porosity from hydrogen gas. The existence of the H2 can be caused by the casting process and dies design that is less perfect, especially at the gate or brisket and overflow. This research is to optimize the process of making Al part handle lever, and the construction dies by following the standard. The results of these improvements were reevaluated through the chemical and mechanical testing properties stages, such as density test and tensile test on the workpiece as part handle lever. The loads on the tensile test are 25 kg and 35 kg, and the tensile test result has met the standard set by the motor vehicle company. The optimization result has the porosity defect can be reduced by 99 %. Therefore the best part handle lever can be produced.
Parker, David; Belaud-Rotureau, Marc-Antoine
2014-01-01
Break-apart fluorescence in situ hybridization (FISH) is the gold standard test for anaplastic lymphoma kinase (ALK) gene rearrangement. However, this methodology often is assumed to be expensive and potentially cost-prohibitive given the low prevalence of ALK-positive non-small cell lung cancer (NSCLC) cases. To more accurately estimate the cost of ALK testing by FISH, we developed a micro-cost model that accounts for all cost elements of the assay, including laboratory reagents, supplies, capital equipment, technical and pathologist labor, and the acquisition cost of the commercial test and associated reagent kits and controls. By applying a set of real-world base-case parameter values, we determined that the cost of a single ALK break-apart FISH test result is $278.01. Sensitivity analysis on the parameters of batch size, testing efficiency, and the cost of the commercial diagnostic testing products revealed that the cost per result is highly sensitive to batch size, but much less so to efficiency or product cost. This implies that ALK testing by FISH will be most cost effective when performed in high-volume centers. Our results indicate that testing cost may not be the primary determinant of crizotinib (Xalkori(®)) treatment cost effectiveness, and suggest that testing cost is an insufficient reason to limit the use of FISH testing for ALK rearrangement.
Parker, David; Belaud-Rotureau, Marc-Antoine
2014-01-01
Break-apart fluorescence in situ hybridization (FISH) is the gold standard test for anaplastic lymphoma kinase (ALK) gene rearrangement. However, this methodology often is assumed to be expensive and potentially cost-prohibitive given the low prevalence of ALK-positive non-small cell lung cancer (NSCLC) cases. To more accurately estimate the cost of ALK testing by FISH, we developed a micro-cost model that accounts for all cost elements of the assay, including laboratory reagents, supplies, capital equipment, technical and pathologist labor, and the acquisition cost of the commercial test and associated reagent kits and controls. By applying a set of real-world base-case parameter values, we determined that the cost of a single ALK break-apart FISH test result is $278.01. Sensitivity analysis on the parameters of batch size, testing efficiency, and the cost of the commercial diagnostic testing products revealed that the cost per result is highly sensitive to batch size, but much less so to efficiency or product cost. This implies that ALK testing by FISH will be most cost effective when performed in high-volume centers. Our results indicate that testing cost may not be the primary determinant of crizotinib (Xalkori®) treatment cost effectiveness, and suggest that testing cost is an insufficient reason to limit the use of FISH testing for ALK rearrangement. PMID:25520569
Moretti, Stefano; van Leeuwen, Danitsja; Gmuender, Hans; Bonassi, Stefano; van Delft, Joost; Kleinjans, Jos; Patrone, Fioravante; Merlo, Domenico Franco
2008-01-01
Background In gene expression analysis, statistical tests for differential gene expression provide lists of candidate genes having, individually, a sufficiently low p-value. However, the interpretation of each single p-value within complex systems involving several interacting genes is problematic. In parallel, in the last sixty years, game theory has been applied to political and social problems to assess the power of interacting agents in forcing a decision and, more recently, to represent the relevance of genes in response to certain conditions. Results In this paper we introduce a Bootstrap procedure to test the null hypothesis that each gene has the same relevance between two conditions, where the relevance is represented by the Shapley value of a particular coalitional game defined on a microarray data-set. This method, which is called Comparative Analysis of Shapley value (shortly, CASh), is applied to data concerning the gene expression in children differentially exposed to air pollution. The results provided by CASh are compared with the results from a parametric statistical test for testing differential gene expression. Both lists of genes provided by CASh and t-test are informative enough to discriminate exposed subjects on the basis of their gene expression profiles. While many genes are selected in common by CASh and the parametric test, it turns out that the biological interpretation of the differences between these two selections is more interesting, suggesting a different interpretation of the main biological pathways in gene expression regulation for exposed individuals. A simulation study suggests that CASh offers more power than t-test for the detection of differential gene expression variability. Conclusion CASh is successfully applied to gene expression analysis of a data-set where the joint expression behavior of genes may be critical to characterize the expression response to air pollution. We demonstrate a synergistic effect between coalitional games and statistics that resulted in a selection of genes with a potential impact in the regulation of complex pathways. PMID:18764936
Modal Analysis of MARS Solar Panel and Planar Vibrations
NASA Technical Reports Server (NTRS)
Simonyan, Andranik; Williams, R. Brett
2007-01-01
This slide presentation reviews the modal analysis of MARS solar panels and the planar vibrations. Included are views of the solar panels mock-up assembly, a view of the test seup,a view of the plot from the test, with the raw numbers of the frequencies in Hz values with the mode number, the spatial acceleration plots of Center sub panel at resonant frequencies, predictions from the Finite element models, an explanation of the two test that were done on the plate and the results from both tests,
SFDT-1 Camera Pointing and Sun-Exposure Analysis and Flight Performance
NASA Technical Reports Server (NTRS)
White, Joseph; Dutta, Soumyo; Striepe, Scott
2015-01-01
The Supersonic Flight Dynamics Test (SFDT) vehicle was developed to advance and test technologies of NASA's Low Density Supersonic Decelerator (LDSD) Technology Demonstration Mission. The first flight test (SFDT-1) occurred on June 28, 2014. In order to optimize the usefulness of the camera data, analysis was performed to optimize parachute visibility in the camera field of view during deployment and inflation and to determine the probability of sun-exposure issues with the cameras given the vehicle heading and launch time. This paper documents the analysis, results and comparison with flight video of SFDT-1.
Journal of Naval Science. Volume 2, Number 1
1976-01-01
has defined a probability distribution function which fits this type of data and forms the basis for statistical analysis of test results (see...Conditions to Assess the Performance of Fire-Resistant Fluids’. Wear, 28 (1974) 29. J.N.S., Vol. 2, No. 1 APPENDIX A Analysis of Fatigue Test Data...used to produce the impulse response and the equipment required for the analysis is relatively simple. The methods that must be used to produce
Advanced Thermal Simulator Testing: Thermal Analysis and Test Results
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Dickens, Ricky; Dixon, David; Reid, Robert; Adams, Mike; Davis, Joe
2008-01-01
Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a SNAP derivative reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.
Agapova, Maria; Duignan, Andrea; Smith, Alan; O'Neill, Ciaran; Basu, Anirban
2018-01-01
Introduction Co-testing (cytology plus human papillomavirus DNA testing) as part of cervical cancer surveillance in Ireland increases one-time testing costs. Of interest to policy makers was the long-term impact of these costs accompanied by decreases in intensity of recalls for women with no detected abnormalities. Methods A cost-analysis of cytology-only and co-testing was implemented using decision analytic modeling, aggregating testing utilization and costs for each of the two strategies over 12 years. Results Aggregated incremental costs of the co-testing strategy were positive for the first 3 years but became negative thereafter, generating a cost savings of roughly €20 million in favor of the cytology-only strategy over a 12-year period. Results were robust over a range of sensitivity analyses with respect to discount and attrition rates. Discussion This analysis provided valuable information to policy makers contributing to the introduction of co-testing for post-treatment surveillance in Ireland. PMID:26377838
NASA Technical Reports Server (NTRS)
Foote, C. H.
1980-01-01
Results from the altitude testing of a P sub T/P sub S noseboom probe on the F100 engine are discused. The results are consistent with sea level test results. The F100 engine altitude test verified automatic downmatch with the engine pressure ratio control, and backup control inlet case static pressure demonstrated sufficient accuracy for backup control fuel flow scheduling. The production P6 probe measured Station 6 pressures accurately for both undistorted and distorted inlet airflows.
Reliability Measure of a Clinical Test: Appreciation of Music in Cochlear Implantees (AMICI)
Cheng, Min-Yu; Spitzer, Jaclyn B.; Shafiro, Valeriy; Sheft, Stanley; Mancuso, Dean
2014-01-01
Purpose The goals of this study were (1) to investigate the reliability of a clinical music perception test, Appreciation of Music in Cochlear Implantees (AMICI), and (2) examine associations between the perception of music and speech. AMICI was developed as a clinical instrument for assessing music perception in persons with cochlear implants (CIs). The test consists of four subtests: (1) music versus environmental noise discrimination, (2) musical instrument identification (closed-set), (3) musical style identification (closed-set), and (4) identification of musical pieces (open-set). To be clinically useful, it is crucial for AMICI to demonstrate high test-retest reliability, so that CI users can be assessed and retested after changes in maps or programming strategies. Research Design Thirteen CI subjects were tested with AMICI for the initial visit and retested again 10–14 days later. Two speech perception tests (consonant-nucleus-consonant [CNC] and Bamford-Kowal-Bench Speech-in-Noise [BKB-SIN]) were also administered. Data Analysis Test-retest reliability and equivalence of the test’s three forms were analyzed using paired t-tests and correlation coefficients, respectively. Correlation analysis was also conducted between results from the music and speech perception tests. Results Results showed no significant difference between test and retest (p > 0.05) with adequate power (0.9) as well as high correlations between the three forms (Forms A and B, r = 0.91; Forms A and C, r = 0.91; Forms B and C, r = 0.95). Correlation analysis showed high correlation between AMICI and BKB-SIN (r = −0.71), and moderate correlation between AMICI and CNC (r = 0.4). Conclusions The study showed AMICI is highly reliable for assessing musical perception in CI users. PMID:24384082
Design/Analysis of Metal/Composite Bonded Joints for Survivability at Cryogenic Temperatures
NASA Technical Reports Server (NTRS)
Bartoszyk, Andrew E.
2004-01-01
A major design and analysis challenge for the JWST ISM structure is the metal/composite bonded joints that will be required to survive down to an operational ultra-low temperature of 30K (-405 F). The initial and current baseline design for the plug-type joint consists of a titanium thin walled fitting (1-3mm thick) bonded to the interior surface of an M555/954-6 composite truss square tube with an axially stiff biased lay-up. Metallic fittings are required at various nodes of the truss structure to accommodate instrument and lift-point bolted interfaces. Analytical experience and design work done on metal/composite bonded joints at temperatures below liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are virtually nonexistent. Increasing the challenge is the difficulty in testing for these required tools and parameters at 30K. A preliminary finite element analysis shows that failure due to CTE mismatch between the biased composite and titanium or aluminum is likely. Failure is less likely with Invar, however an initial mass estimate of Invar fittings demonstrates that Invar is not an automatic alternative. In order to gain confidence in analyzing and designing the ISM joints, a comprehensive joint development testing program has been planned and is currently running. The test program is designed for the correlation of the analysis methodology, including tuning finite element model parameters, and developing a composite failure criterion for the effect of multi-axial composite stresses on the strength of a bonded joint at 30K. The testing program will also consider stress mitigation using compliant composite layers and potential strength degradation due to multiple thermal cycles. Not only will the finite element analysis be correlated to the test data, but the FEA will be used to guide the design of the test. The first phase of the test program has been completed and the preliminary analysis has been revisited based on the test data In this work, we present an overview of the test plan, results today, and resulting design improvements.
Analysis of Slug Tests in Formations of High Hydraulic Conductivity
Butler, J.J.; Garnett, E.J.; Healey, J.M.
2003-01-01
A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.
Analysis of slug tests in formations of high hydraulic conductivity.
Butler, James J; Garnett, Elizabeth J; Healey, John M
2003-01-01
A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.
NASA Technical Reports Server (NTRS)
Taleghani, Barmac K.; Pappa, Richard S.
1996-01-01
Structural materials in the form of graphite epoxy composites with embedded rubber layers are being used to reduce vibrations in rocket motor tubes. Four filament-wound, graphite epoxy tubes were studied to evaluate the effects of the rubber layer on the modal parameters (natural vibration frequencies, damping, and mode shapes). Tube 1 contained six alternating layers of 30-degree helical wraps and 90-degree hoop wraps. Tube 2 was identical to tube 1 with the addition of an embedded 0.030-inch-thick rubber layer. Tubes 3 and 4 were identical to tubes 1 and 2, respectively, with the addition of a Textron Kelpoxy elastomer. This report compares experimental modal parameters obtained by impact testing with analytical modal parameters obtained by NASTRAN finite-element analysis. Four test modes of tube 1 and five test modes of tube 3 correlate highly with corresponding analytical predictions. Unsatisfactory correlation of test and analysis results occurred for tubes 2 and 4 and these comparisons are not shown. Work is underway to improve the analytical models of these tubes. Test results clearly show that the embedded rubber layers significantly increase structural modal damping as well as decrease natural vibration frequencies.
Bohling, Geoffrey C.; Butler, James J.; Zhan, Xiaoyong; Knoll, Michael D.
2007-01-01
Hydraulic tomography is a promising approach for obtaining information on variations in hydraulic conductivity on the scale of relevance for contaminant transport investigations. This approach involves performing a series of pumping tests in a format similar to tomography. We present a field‐scale assessment of hydraulic tomography in a porous aquifer, with an emphasis on the steady shape analysis methodology. The hydraulic conductivity (K) estimates from steady shape and transient analyses of the tomographic data compare well with those from a tracer test and direct‐push permeameter tests, providing a field validation of the method. Zonations based on equal‐thickness layers and cross‐hole radar surveys are used to regularize the inverse problem. The results indicate that the radar surveys provide some useful information regarding the geometry of the K field. The steady shape analysis provides results similar to the transient analysis at a fraction of the computational burden. This study clearly demonstrates the advantages of hydraulic tomography over conventional pumping tests, which provide only large‐scale averages, and small‐scale hydraulic tests (e.g., slug tests), which cannot assess strata connectivity and may fail to sample the most important pathways or barriers to flow.
Issue a Boil-Water Advisory or Wait for Definitive Information? A Decision Analysis
Wagner, Michael M.; Wallstrom, Garrick L.; Onisko, Agnieszka
2005-01-01
Objective Study the decision to issue a boil-water advisory in response to a spike in sales of diarrhea remedies or wait 72 hours for the results of definitive testing of water and people. Methods Decision analysis. Results In the base-case analysis, the optimal decision is test-and-wait. If the cost of issuing a boil-water advisory is less than 13.92 cents per person per day, the optimal decision is to issue the boil-water advisory immediately. Conclusions Decisions based on surveillance data that are suggestive but not conclusive about the existence of a disease outbreak can be modeled. PMID:16779145
Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testingmore » by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less
Test and Analysis of a Hyper-X Carbon-Carbon Leading Edge Chine
NASA Technical Reports Server (NTRS)
Smith, Russell W.; Sikora, Joseph G.; Lindell, Michael C.
2005-01-01
During parts production for the X43A Mach 10 hypersonic vehicle nondestructive evaluation (NDE) of a leading edge chine detected on imbedded delamination near the lower surface of the part. An ultimate proof test was conducted to verify the ultimate strength of this leading edge chine part. The ultimate proof test setup used a pressure bladder design to impose a uniform distributed pressure field over the bi-planar surface of the chine test article. A detailed description of the chine test article and experimental test setup is presented. Analysis results from a linear status model of the test article are also presented and discussed. Post-test inspection of the specimen revealed no visible failures or areas of delamination.
Analysis of gunshot residue test results in 112 suicides.
Reed, G E; McGuire, P J; Boehm, A
1990-01-01
The results of gunshot residue (GSR) tests in 112 suicide cases investigated by the U.S. Army Criminal Investigation Command over a ten-year period are described. Only suicide cases in which there was certainty that the victim fired a weapon were examined in an effort to reduce ambiguous results. Previous case work research by Rudzitis indicated that positive GSR test results were encountered in suicides 62% of the time using various combinations of neutron activation analysis (NAA) and atomic absorption spectrophotometry (AAS). Threshold values of 0.2-micrograms antimony and 0.3-micrograms barium (0.2-micrograms antimony and 0.5-micrograms barium after 1985) used by the U.S. Army Criminal Investigation Laboratory resulted in positive GSR results in suicide cases 38% of the time. The effects of time, location of body, handling of the body, weapon type, caliber, and condition of the hands on GSR results are examined. Case studies involving suicides by unit armorers are discussed.
In-air RBS measurements at the LAMFI external beam setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silva, T. F.; Added, N.; Moro, M. V.
2014-11-11
This work describes new developments in the external beam setup of the Laboratory of Material Analysis with Ion Beams of the University of São Paulo (LAMFI-USP). This setup was designed to be a versatile analytical station to analyze a broad range of samples. In recent developments, we seek the external beam Rutherford Backscattering Spectroscopy (RBS) analysis to complement the Particle Induced X-ray Emission (PIXE) measurements. This work presents the initial results of the external beam RBS analysis as well as recent developments to improve the energy resolution RBS measurements, in particular tests to seek for sources of resolution degradation. Thesemore » aspects are discussed and preliminary results of in-air RBS analysis of some test samples are presented.« less
On the Likelihood Ratio Test for the Number of Factors in Exploratory Factor Analysis
ERIC Educational Resources Information Center
Hayashi, Kentaro; Bentler, Peter M.; Yuan, Ke-Hai
2007-01-01
In the exploratory factor analysis, when the number of factors exceeds the true number of factors, the likelihood ratio test statistic no longer follows the chi-square distribution due to a problem of rank deficiency and nonidentifiability of model parameters. As a result, decisions regarding the number of factors may be incorrect. Several…
ERIC Educational Resources Information Center
Yeo, Seungsoo
2010-01-01
The purpose of this synthesis was to examine the relationship between Curriculum-Based Measurement (CBM) and statewide achievement tests in reading. A multilevel meta-analysis was used to calculate the correlation coefficient of the population for 27 studies that met the inclusion criteria. Results showed an overall large correlation coefficient…
Weiss, Noel S
2013-04-01
In recent years, a number of studies have achieved randomization of patients to alternative management strategies by blinding some patients (and their providers of medical care) to the results of tests that guide such strategies. Although this research approach has the potential to be a powerful means of measuring treatment effectiveness, the interpretation of the results may not be straightforward if the treatment received by test-positive persons is variable or not well documented, or if the analysis is not restricted to outcomes in test-positive persons. Studies in which the test results are withheld at random may face ethical issues that, to date, have received little discussion. Copyright © 2013 Elsevier Inc. All rights reserved.
Functional connectivity in resting state as a phonemic fluency ability measure.
Miró-Padilla, Anna; Bueichekú, Elisenda; Ventura-Campos, Noelia; Palomar-García, María-Ángeles; Ávila, César
2017-03-01
There is some evidence that functional connectivity (FC) measures obtained at rest may reflect individual differences in cognitive capabilities. We tested this possibility by using the FAS test as a measure of phonemic fluency. Seed regions of the main brain areas involved in this task were extracted from meta-analysis results (Wagner et al., 2014) and used for pairwise resting-state FC analysis. Ninety-three undergraduates completed the FAS test outside the scanner. A correlation analysis was conducted between the F-A-S scores (behavioral testing) and the pairwise FC pattern of verbal fluency regions of interest. Results showed that the higher FC between the thalamus and the cerebellum, and the lower FCs between the left inferior frontal gyrus and the right insula and between the supplementary motor area and the right insula were associated with better performance on the FAS test. Regression analyses revealed that the first two FCs contributed independently to this better phonemic fluency, reflecting a more general attentional factor (FC between thalamus and cerebellum) and a more specific fluency factor (FC between the left inferior frontal gyrus and the right insula). The results support the Spontaneous Trait Reactivation hypothesis, which explains how resting-state derived measures may reflect individual differences in cognitive abilities. Copyright © 2017 Elsevier Ltd. All rights reserved.
High-Speed Research: 1994 Sonic Boom Workshop. Configuration, Design, Analysis and Testing
NASA Technical Reports Server (NTRS)
McCurdy, David A. (Editor)
1999-01-01
The third High-Speed Research Sonic Boom Workshop was held at NASA Langley Research Center on June 1-3, 1994. The purpose of this workshop was to provide a forum for Government, industry, and university participants to present and discuss progress in their research. The workshop was organized into sessions dealing with atmospheric propagation; acceptability studies; and configuration design, and testing. Attendance at the workshop was by invitation only. The workshop proceedings include papers on design, analysis, and testing of low-boom high-speed civil transport configurations and experimental techniques for measuring sonic booms. Significant progress is noted in these areas in the time since the previous workshop a year earlier. The papers include preliminary results of sonic boom wind tunnel tests conducted during 1993 and 1994 on several low-boom designs. Results of a mission performance analysis of all low-boom designs are also included. Two experimental methods for measuring near-field signatures of airplanes in flight are reported.
RERTR-8 Irradiation Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. M. Perez; M. A. Lillo; G. S. Chang
2011-12-01
The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-8, was designed to test monolithic mini-fuel plates fabricated via hot isostatic pressing (HIP), the effect of molybdenum (Mo) content on the monolithic fuel behavior, and the efficiency of ternary additions to dispersion fuel particles on the interaction layer behavior at higher burnup. The following report summarizes the life of the RERTR-8 experiment through end of irradiation, including as-run neutronic analysis, thermal analysis and hydraulic testing results.
NASA Astrophysics Data System (ADS)
Marshall, Jill A.; Hagedorn, Eric A.; O'Connor, Jerry
2009-06-01
We report the results of an analysis of the Texas Assessment of Knowledge and Skills (TAKS) designed to determine whether the TAKS is a valid indicator of whether students know and can do physics at the level necessary for success in future coursework, STEM careers, and life in a technological society. We categorized science items from the 2003 and 2004 10th and 11th grade TAKS by content area(s) covered, knowledge and skills required to select the correct answer, and overall quality. We also analyzed a 5000 student sample of item-level results from the 2004 11th grade exam, performing full-information factor analysis, calculating classical test indices, and determining each item's response curve using item response theory. Triangulation of our results revealed strengths and weaknesses of the different methods of analysis. The TAKS was found to be only weakly indicative of physics preparation and we make recommendations for increasing the validity of standardized physics testing.
On the use of external burning to reduce aerospace vehicle transonic drag
NASA Technical Reports Server (NTRS)
Trefny, Charles J.
1990-01-01
The external combustion of hydrogen to reduce the transonic drag of aerospace vehicles is currently being investigated. A preliminary analysis based on a constant pressure control volume is discussed. Results indicate that the specific impulse of the external burning process rivals that of a turbojet and depends on the severity of the initial base drag as well as on the Mach flight number and the equivalence ratio. A test program was conducted to investigate hydrogen-air flame stability at the conditions of interest and to demonstrate drag reduction on a simple expansion ramp. Initial test results are presented and compared with the control-volume analysis. The expansion ramp surface pressure coefficient showed little variation with fuel pressure and altitude, in disagreement with the analysis. Flame stability results were encouraging and indicate that stable combustion is possible over an adequate range of conditions. Facility interference and chemical kinetics phenomena that make interpretation of subscale ground test data difficult are discussed.
Methodenvergleich zur Bestimmung der hydraulischen Durchlässigkeit
NASA Astrophysics Data System (ADS)
Storz, Katharina; Steger, Hagen; Wagner, Valentin; Bayer, Peter; Blum, Philipp
2017-06-01
Knowing the hydraulic conductivity (K) is a precondition for understanding groundwater flow processes in the subsurface. Numerous laboratory and field methods for the determination of hydraulic conductivity exist, which can lead to significantly different results. In order to quantify the variability of these various methods, the hydraulic conductivity was examined for an industrial silica sand (Dorsilit) using four different methods: (1) grain-size analysis, (2) Kozeny-Carman approach, (3) permeameter tests and (4) flow rate experiments in large-scale tank experiments. Due to the large volume of the artificially built aquifer, the tank experiment results are assumed to be the most representative. Hydraulic conductivity values derived from permeameter tests show only minor deviation, while results of the empirically evaluated grain-size analysis are about one magnitude higher and show great variances. The latter was confirmed by the analysis of several methods for the determination of K-values found in the literature, thus we generally question the suitability of grain-size analyses and strongly recommend the use of permeameter tests.
Examining Evolving Performance on the Force Concept Inventory Using Factor Analysis
ERIC Educational Resources Information Center
Semak, M. R.; Dietz, R. D.; Pearson, R. H.; Willis, C. W
2017-01-01
The application of factor analysis to the "Force Concept Inventory" (FCI) has proven to be problematic. Some studies have suggested that factor analysis of test results serves as a helpful tool in assessing the recognition of Newtonian concepts by students. Other work has produced at best ambiguous results. For the FCI administered as a…
NASA Astrophysics Data System (ADS)
Takamatsu, Kuniyoshi; Nakagawa, Shigeaki; Takeda, Tetsuaki
Safety demonstration tests using the High Temperature Engineering Test Reactor (HTTR) are in progress to verify its inherent safety features and improve the safety technology and design methodology for High-temperature Gas-cooled Reactors (HTGRs). The reactivity insertion test is one of the safety demonstration tests for the HTTR. This test simulates the rapid increase in the reactor power by withdrawing the control rod without operating the reactor power control system. In addition, the loss of coolant flow tests has been conducted to simulate the rapid decrease in the reactor power by tripping one, two or all out of three gas circulators. The experimental results have revealed the inherent safety features of HTGRs, such as the negative reactivity feedback effect. The numerical analysis code, which was named-ACCORD-, was developed to analyze the reactor dynamics including the flow behavior in the HTTR core. We have modified this code to use a model with four parallel channels and twenty temperature coefficients. Furthermore, we added another analytical model of the core for calculating the heat conduction between the fuel channels and the core in the case of the loss of coolant flow tests. This paper describes the validation results for the newly developed code using the experimental results. Moreover, the effect of the model is formulated quantitatively with our proposed equation. Finally, the pre-analytical result of the loss of coolant flow test by tripping all gas circulators is also discussed.
Testing students' e-learning via Facebook through Bayesian structural equation modeling.
Salarzadeh Jenatabadi, Hashem; Moghavvemi, Sedigheh; Wan Mohamed Radzi, Che Wan Jasimah Bt; Babashamsi, Parastoo; Arashi, Mohammad
2017-01-01
Learning is an intentional activity, with several factors affecting students' intention to use new learning technology. Researchers have investigated technology acceptance in different contexts by developing various theories/models and testing them by a number of means. Although most theories/models developed have been examined through regression or structural equation modeling, Bayesian analysis offers more accurate data analysis results. To address this gap, the unified theory of acceptance and technology use in the context of e-learning via Facebook are re-examined in this study using Bayesian analysis. The data (S1 Data) were collected from 170 students enrolled in a business statistics course at University of Malaya, Malaysia, and tested with the maximum likelihood and Bayesian approaches. The difference between the two methods' results indicates that performance expectancy and hedonic motivation are the strongest factors influencing the intention to use e-learning via Facebook. The Bayesian estimation model exhibited better data fit than the maximum likelihood estimator model. The results of the Bayesian and maximum likelihood estimator approaches are compared and the reasons for the result discrepancy are deliberated.
Testing students’ e-learning via Facebook through Bayesian structural equation modeling
Moghavvemi, Sedigheh; Wan Mohamed Radzi, Che Wan Jasimah Bt; Babashamsi, Parastoo; Arashi, Mohammad
2017-01-01
Learning is an intentional activity, with several factors affecting students’ intention to use new learning technology. Researchers have investigated technology acceptance in different contexts by developing various theories/models and testing them by a number of means. Although most theories/models developed have been examined through regression or structural equation modeling, Bayesian analysis offers more accurate data analysis results. To address this gap, the unified theory of acceptance and technology use in the context of e-learning via Facebook are re-examined in this study using Bayesian analysis. The data (S1 Data) were collected from 170 students enrolled in a business statistics course at University of Malaya, Malaysia, and tested with the maximum likelihood and Bayesian approaches. The difference between the two methods’ results indicates that performance expectancy and hedonic motivation are the strongest factors influencing the intention to use e-learning via Facebook. The Bayesian estimation model exhibited better data fit than the maximum likelihood estimator model. The results of the Bayesian and maximum likelihood estimator approaches are compared and the reasons for the result discrepancy are deliberated. PMID:28886019
Finite Element Analysis and Test Correlation of a 10-Meter Inflation-Deployed Solar Sail
NASA Technical Reports Server (NTRS)
Sleight, David W.; Michii, Yuki; Lichodziejewski, David; Derbes, Billy; Mann. Troy O.; Slade, Kara N.; Wang, John T.
2005-01-01
Under the direction of the NASA In-Space Propulsion Technology Office, the team of L Garde, NASA Jet Propulsion Laboratory, Ball Aerospace, and NASA Langley Research Center has been developing a scalable solar sail configuration to address NASA's future space propulsion needs. Prior to a flight experiment of a full-scale solar sail, a comprehensive phased test plan is currently being implemented to advance the technology readiness level of the solar sail design. These tests consist of solar sail component, subsystem, and sub-scale system ground tests that simulate the vacuum and thermal conditions of the space environment. Recently, two solar sail test articles, a 7.4-m beam assembly subsystem test article and a 10-m four-quadrant solar sail system test article, were tested in vacuum conditions with a gravity-offload system to mitigate the effects of gravity. This paper presents the structural analyses simulating the ground tests and the correlation of the analyses with the test results. For programmatic risk reduction, a two-prong analysis approach was undertaken in which two separate teams independently developed computational models of the solar sail test articles using the finite element analysis software packages: NEiNastran and ABAQUS. This paper compares the pre-test and post-test analysis predictions from both software packages with the test data including load-deflection curves from static load tests, and vibration frequencies and mode shapes from vibration tests. The analysis predictions were in reasonable agreement with the test data. Factors that precluded better correlation of the analyses and the tests were uncertainties in the material properties, test conditions, and modeling assumptions used in the analyses.
Limits of clinical tests to screen autonomic function in diabetes type 1.
Ducher, M; Bertram, D; Sagnol, I; Cerutti, C; Thivolet, C; Fauvel, J P
2001-11-01
A precocious detection of cardiac autonomic dysfunction is of major clinical interest that could lead to a more intensive supervision of diabetic patients. However, classical clinical exploration of cardiac autonomic function is not easy to undertake in a reproducible way. Thus, respective interests of autonomic nervous parameters provided by both clinical tests and computerized analysis of resting blood pressure were checked in type 1 diabetic patients without orthostatic hypotension and microalbuminuria. Thirteen diabetic subjects matched for age and gender to thirteen healthy subjects volunteered to participate to the study. From clinical tests (standing up, deep breathing, Valsalva maneuver, handgrip test), autonomic function was scored according to Ewing's methodology. Analysis of resting beat to beat blood pressure provided autonomic indices of the cardiac function (spectral analysis or Z analysis). 5 of the 13 diabetic patients exhibited a pathological score (more than one pathological response) suggesting the presence of cardiovascular autonomic dysfunction. The most discriminative test was the deep breathing test. However, spectral indices of BP recordings and baro-reflex sensitivity (BRS) of these 5 subjects were similar to those of healthy subjects and of remaining diabetic subjects. Alteration in Ewing's score given by clinical tests may not reflect an alteration of cardiac autonomic function in asymptomatic type 1 diabetic patients, because spectral indices of sympathetic and parasympathetic (including BRS) function were within normal range. Our results strongly suggest to confront results provided by both methodologies before concluding to an autonomic cardiac impairment in asymptomatic diabetic patients.
NASA Technical Reports Server (NTRS)
Hiltner, Dale; McKee, Michael; LaNoe, Karine; Gregorek, Gerald; Ratvasky, Thomas (Technical Monitor)
2000-01-01
Ice contaminated tailplane stall (ICTS) has been found to be responsible for 16 accidents with 139 fatalities over the last three decades, and is suspected to have played a role in other accidents and incidents. The need for fundamental research in this area has been recognized at three international conferences sponsored by the FAA since 1991. In order to conduct such research, a joint NASA/FAA Tailplane Icing Program was formed in 1994: the Ohio State University has played an important role in this effort. The program employs icing tunnel testing, dry wind tunnel testing, flight testing, and analysis using a six-degrees-of-freedom computer code tailored to this problem. A central goal is to quantify the effect of tailplane icing on aircraft stability and control to aid in the analysis of flight test procedures to identify aircraft susceptibility to ICTS. This report contains the results ot testing of a full scale 2D model of a tailplane section of NASA's Icing Research Aircraft, with and without ice shapes, in an Ohio State University 7 x 10 Low Speed wind tunnel in 1994. The results have been integrated into a comprehensive database of aerodynamic coefficients and stability and control derivatives that will permit detailed analysis of flight test results with the analytical computer program. The testing encompassed a full range of angles of attack and elevator deflections, as well as two velocities to evaluate Reynolds number effects. Lift, drag, pitching moment, and hinge moment coefficients were obtained. In addition. instrumentation for use during flight testing was verified to be effective, all components showing acceptable fidelity. Comparison of clean and iced airfoil results show the ice shapes causing a significant decrease in the magnitude of CLmax (from -1.3 to -0.64) and associated stall angle (from -18.6 deg to -8.2 deg). Furthermore, the ice shapes caused an increase in hinge moment coefficient of approximately 0.02, the change being markedly abrupt for one of the ice shapes. A noticeable effect of elevator deflection is that magnitude of the stall angle is decreased for negative (upward) elevator deflections. All these result are consistent with observed tailplane phenomena. and constitute an effective set of data for comprehensive analysis of ICTS
1983-06-01
Field Control Results 18 - Record Test Results 18 GRAVEL DRAIN MATERIAL, 19 FILTER MATERIAL, 20 ABUTMET INFILL MATERIAL- 20 X. EMBANKMENT ANALYSIS 21 XI...Thirty-three in-situ density tests were conducted in the near surface embankment foundation materials by the sand displacement method . An additional...seven densities were obtained from undisturbed samples by the bulk density method . The results of density tests in the foundation are shown on plate
Analysis of EUVE Experiment Results
NASA Technical Reports Server (NTRS)
Horan, Stephen
1996-01-01
A series of tests to validate an antenna pointing concept for spin-stabilized satellites using a data relay satellite are described. These tests show that proper antenna pointing on an inertially-stabilized spacecraft can lead to significant access time through the relay satellite even without active antenna pointing. We summarize the test results, the simulations to model the effects of antenna pattern and space loss, and the expected contact times. We also show how antenna beam width affects the results.
[Interpretation of false positive results of biochemical prenatal tests].
Sieroszewski, Piotr; Słowakiewicz, Katarzyna; Perenc, Małgorzata
2010-03-01
Modern, non-invasive prenatal diagnostics based on biochemical and ultrasonographic markers of fetal defects allows us to calculate the risk of fetal chromosomal aneuploidies with high sensitivity and specificity An introduction of biochemical, non-invasive prenatal tests turned out to result in frequent false positive results of these tests in cases when invasive diagnostics does not confirm fetal defects. However prospective analysis of these cases showed numerous complications in the third trimester of the pregnancies.
One-Dimensional Model for Mud Flows.
1985-10-01
law relation between the Chezy coefficient and the flow Reynolds number. Jeyapalan et al. [2], in their analysis of mine tailing dam failures...8217.. .: -:.. ; .r;./. : ... . :\\ :. . ... . RESULTS The model is compared with several dambreak experiments performed by Jeyapalan et al. [3]. In these...0.34 seconds per computational node. 5i Test 6 Test 2 Test 7 44 E 3 A2 Experimental Results0 Jeyapalan at al. (3) - C6- Numerical Results 4 8 12 i6 Time
Revised Robertson's test theory of special relativity
NASA Astrophysics Data System (ADS)
Vargas, José G.
1984-07-01
The only test theory used by workers in the field of testing special relativity to analyze the significance of their experiments is the proof by H. P. Robertson [ Rev. Mod. Phys. 21, 378 (1949)] of the Lorentz transformations from the results of the experimental evidence. Some researchers would argue that the proof contains an unwarranted assumption disguised as a convention about synchronization procedures. Others would say that alternative conventions are possible. In the present paper, no convention is used, but the Lorentz transformations are still obtained using only the results of the experiments in Robertson's proof, namely the Michelson-Morley, Kennedy-Thorndike, and Ives-Stilwell experiments. Thus the revised proof is a valid test theory which is independent of any conventions, since one appeals only to the experimental evidence. The analysis of that evidence shows the directions in which efforts to test special relativity should go. Finally it is shown how the resulting test theory still has to be improved for consistency in the analysis of experiments with complicated experimental setups, how it can be simplified for expediency as to what should be tested, and how it should be completed for a missing step not considered by Robertson.
Performance testing and analysis results of AMTEC cells for space applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borkowski, C.A.; Barkan, A.; Hendricks, T.J.
1998-01-01
Testing and analysis has shown that AMTEC (Alkali Metal Thermal to Electric Conversion) (Weber, 1974) cells can reach the performance (power) levels required by a variety of space applications. The performance of an AMTEC cell is highly dependent on the thermal environment to which it is subjected. A guard heater assembly has been designed, fabricated, and used to expose individual AMTEC cells to various thermal environments. The design and operation of the guard heater assembly will be discussed. Performance test results of an AMTEC cell operated under guard heated conditions to simulate an adiabatic cell wall thermal environment are presented.more » Experimental data and analytic model results are compared to illustrate validation of the model. {copyright} {ital 1998 American Institute of Physics.}« less
Study of a solid hydrogen cooler for spacecraft instruments and sensors
NASA Astrophysics Data System (ADS)
Sherman, A.
1980-08-01
The results of tests and studies to investigate the utilization of solid hydrogen for cooling of spacecraft instruments and sensors are presented. The results are presented in two sections; the first describing the tests in which an existing single stage solid cooler was filled and tested with solid hydrogen and the second which describes the analysis and design of a catalytic converter which will be tested in the vent line of the cooler.
Study of a solid hydrogen cooler for spacecraft instruments and sensors
NASA Technical Reports Server (NTRS)
Sherman, A.
1980-01-01
The results of tests and studies to investigate the utilization of solid hydrogen for cooling of spacecraft instruments and sensors are presented. The results are presented in two sections; the first describing the tests in which an existing single stage solid cooler was filled and tested with solid hydrogen and the second which describes the analysis and design of a catalytic converter which will be tested in the vent line of the cooler.
Flight-determined engine exhaust characteristics of an F404 engine in an F-18 airplane
NASA Technical Reports Server (NTRS)
Ennix, Kimberly A.; Burcham, Frank W., Jr.; Webb, Lannie D.
1993-01-01
The exhaust characteristics of the F-18 aircraft with an F404 engine are examined with reference to the results of an acoustic flight testing program. The discussion covers an overview of the flight test planning, instrumentation, test procedures, data analysis, engine modeling codes, and results. In addition, the paper presents the exhaust velocity and Mach number data for the climb-to-cruise, Aircraft Noise Prediction Program validation, and ground tests.
ERIC Educational Resources Information Center
ALTMANN, BERTHOLD
AFTER A BRIEF SUMMARY OF THE TEST PROGRAM (DESCRIBED MORE FULLY IN LI 000 318), THE STATISTICAL RESULTS TABULATED AS OVERALL "ABC (APPROACH BY CONCEPT)-RELEVANCE RATIOS" AND "ABC-RECALL FIGURES" ARE PRESENTED AND REVIEWED. AN ABSTRACT MODEL DEVELOPED IN ACCORDANCE WITH MAX WEBER'S "IDEALTYPUS" ("DIE OBJEKTIVITAET…
Skin prick tests and allergy diagnosis.
Antunes, João; Borrego, Luís; Romeira, Ana; Pinto, Paula
2009-01-01
Skin testing remains an essential diagnostic tool in modern allergy practice. A significant variability has been reported regarding technical procedures, interpretation of results and documentation. This review has the aim of consolidating methodological recommendations through a critical analysis on past and recent data. This will allow a better understanding on skin prick test (SPT) history; technique; (contra-) indications; interpretation of results; diagnostic pitfalls; adverse reactions; and variability factors.
NASA Technical Reports Server (NTRS)
Bergan, Andrew; Bakuckas, John G., Jr.; Lovejoy, Andrew; Jegley, Dawn; Linton, Kim; Neal, Bert; Korkosz, Gregory; Awerbuch, Jonathan; Tan, Tein-Min
2012-01-01
Integrally stitched composite technology is an area that shows promise in enhancing the structural integrity of aircraft and aerospace structures. The most recent generation of this technology is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. The goal of the PRSEUS concept relevant to this test is to provide damage containment capability for composite structures while reducing overall structural weight. The National Aeronautics and Space Administration (NASA), the Federal Aviation Administration (FAA), and The Boeing Company have partnered in an effort to assess the damage containment features of a full-scale curved PRSEUS panel using the FAA Full-Scale Aircraft Structural Test Evaluation and Research (FASTER) facility. A single PRSEUS test panel was subjected to axial tension, internal pressure, and combined axial tension and internal pressure loads. The test results showed excellent performance of the PRSEUS concept. No growth of Barely Visible Impact Damage (BVID) was observed after ultimate loads were applied. With a two-bay notch severing the central stringer, damage was contained within the two-bay region well above the required limit load conditions. Catastrophic failure was well above the ultimate load level. Information describing the test panel and procedure has been previously presented, so this paper focuses on the experimental procedure, test results, nondestructive inspection results, and preliminary test and analysis correlation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, G.D.; Kukielka, C.A.; Olson, L.M.
The engineering analysis group is responsible for all nuclear plant systems analysis and reactor analysis activities, excluding fuel management analysis, at Pennsylvania Power and Light Company. These activities include making pretest and posttest predictions of startup tests; analyzing unplanned or unexpected transient events; providing technical training to plant personnel; assisting in the development of emergency drill scenarios; providing engineering evaluations to support design and technical specification changes, and evaluating, assessing, and resolving a number of license conditions. Many of these activities have required the direct use of RETRAN models. Two RETRAN analyses that were completed to support plant operations -more » a pretest analysis of the turbine trip startup test, and a posttest analysis of the loss of startup transformer event - are investigated. For each case, RETRAN results are compared with available plant data and comparisons are drawn on the acceptability of the performance of the plant systems.« less
Structural Element Testing in Support of the Design of the NASA Composite Crew Module
NASA Technical Reports Server (NTRS)
Kellas, Sotiris; Jackson, Wade C.; Thesken, John C.; Schleicher, Eric; Wagner, Perry; Kirsch, Michael T.
2012-01-01
In January 2007, the NASA Administrator and Associate Administrator for the Exploration Systems Mission Directorate chartered the NASA Engineering and Safety Center (NESC) to design, build, and test a full-scale Composite Crew Module (CCM). For the design and manufacturing of the CCM, the team adopted the building block approach where design and manufacturing risks were mitigated through manufacturing trials and structural testing at various levels of complexity. Following NASA's Structural Design Verification Requirements, a further objective was the verification of design analysis methods and the provision of design data for critical structural features. Test articles increasing in complexity from basic material characterization coupons through structural feature elements and large structural components, to full-scale structures were evaluated. This paper discusses only four elements tests three of which include joints and one that includes a tapering honeycomb core detail. For each test series included are specimen details, instrumentation, test results, a brief analysis description, test analysis correlation and conclusions.
Structural Analysis of an Inflation-Deployed Solar Sail With Experimental Validation
NASA Technical Reports Server (NTRS)
Sleight, David W.; Michii, Yuki; Lichodziejewski, David; Derbes, Billy; Mann, Troy O.
2005-01-01
Under the direction of the NASA In-Space Propulsion Technology Office, the team of L Garde, NASA Jet Propulsion Laboratory, Ball Aerospace, and NASA Langley Research Center has been developing a scalable solar sail configuration to address NASA s future space propulsion needs. Prior to a flight experiment of a full-scale solar sail, a comprehensive phased test plan is currently being implemented to advance the technology readiness level of the solar sail design. These tests consist of solar sail component, subsystem, and sub-scale system ground tests that simulate the vacuum and thermal conditions of the space environment. Recently, two solar sail test articles, a 7.4-m beam assembly subsystem test article and a 10-m four-quadrant solar sail system test article, were tested in vacuum conditions with a gravity-offload system to mitigate the effects of gravity. This paper presents the structural analyses simulating the ground tests and the correlation of the analyses with the test results. For programmatic risk reduction, a two-prong analysis approach was undertaken in which two separate teams independently developed computational models of the solar sail test articles using the finite element analysis software packages: NEiNastran and ABAQUS. This paper compares the pre-test and post-test analysis predictions from both software packages with the test data including load-deflection curves from static load tests, and vibration frequencies and mode shapes from structural dynamics tests. The analysis predictions were in reasonable agreement with the test data. Factors that precluded better correlation of the analyses and the tests were uncertainties in the material properties, test conditions, and modeling assumptions used in the analyses.
Testing an automated method to estimate ground-water recharge from streamflow records
Rutledge, A.T.; Daniel, C.C.
1994-01-01
The computer program, RORA, allows automated analysis of streamflow hydrographs to estimate ground-water recharge. Output from the program, which is based on the recession-curve-displacement method (often referred to as the Rorabaugh method, for whom the program is named), was compared to estimates of recharge obtained from a manual analysis of 156 years of streamflow record from 15 streamflow-gaging stations in the eastern United States. Statistical tests showed that there was no significant difference between paired estimates of annual recharge by the two methods. Tests of results produced by the four workers who performed the manual method showed that results can differ significantly between workers. Twenty-two percent of the variation between manual and automated estimates could be attributed to having different workers perform the manual method. The program RORA will produce estimates of recharge equivalent to estimates produced manually, greatly increase the speed od analysis, and reduce the subjectivity inherent in manual analysis.
Parallel processing methods for space based power systems
NASA Technical Reports Server (NTRS)
Berry, F. C.
1993-01-01
This report presents a method for doing load-flow analysis of a power system by using a decomposition approach. The power system for the Space Shuttle is used as a basis to build a model for the load-flow analysis. To test the decomposition method for doing load-flow analysis, simulations were performed on power systems of 16, 25, 34, 43, 52, 61, 70, and 79 nodes. Each of the power systems was divided into subsystems and simulated under steady-state conditions. The results from these tests have been found to be as accurate as tests performed using a standard serial simulator. The division of the power systems into different subsystems was done by assigning a processor to each area. There were 13 transputers available, therefore, up to 13 different subsystems could be simulated at the same time. This report has preliminary results for a load-flow analysis using a decomposition principal. The report shows that the decomposition algorithm for load-flow analysis is well suited for parallel processing and provides increases in the speed of execution.
2007 Research and Engineering Annual Report
NASA Technical Reports Server (NTRS)
Stoliker, Patrick; Bowers, Albion; Cruciani, Everlyn
2008-01-01
Selected research and technology activities at NASA Dryden Flight Research Center are summarized. These following activities exemplify the Center's varied and productive research efforts: Developing a Requirements Development Guide for an Automatic Ground Collision Avoidance System; Digital Terrain Data Compression and Rendering for Automatic Ground Collision Avoidance Systems; Nonlinear Flutter/Limit Cycle Oscillations Prediction Tool; Nonlinear System Identification Using Orthonormal Bases: Application to Aeroelastic/Aeroservoelastic Systems; Critical Aerodynamic Flow Feature Indicators: Towards Application with the Aerostructures Test Wing; Multidisciplinary Design, Analysis, and Optimization Tool Development Using a Genetic Algorithm; Structural Model Tuning Capability in an Object-Oriented Multidisciplinary Design, Analysis, and Optimization Tool; Extension of Ko Straight-Beam Displacement Theory to the Deformed Shape Predictions of Curved Structures; F-15B with Phoenix Missile and Pylon Assembly--Drag Force Estimation; Mass Property Testing of Phoenix Missile Hypersonic Testbed Hardware; ARMD Hypersonics Project Materials and Structures: Testing of Scramjet Thermal Protection System Concepts; High-Temperature Modal Survey of the Ruddervator Subcomponent Test Article; ARMD Hypersonics Project Materials and Structures: C/SiC Ruddervator Subcomponent Test and Analysis Task; Ground Vibration Testing and Model Correlation of the Phoenix Missile Hypersonic Testbed; Phoenix Missile Hypersonic Testbed: Performance Design and Analysis; Crew Exploration Vehicle Launch Abort System-Pad Abort-1 (PA-1) Flight Test; Testing the Orion (Crew Exploration Vehicle) Launch Abort System-Ascent Abort-1 (AA-1) Flight Test; SOFIA Flight-Test Flutter Prediction Methodology; SOFIA Closed-Door Aerodynamic Analyses; SOFIA Handling Qualities Evaluation for Closed-Door Operations; C-17 Support of IRAC Engine Model Development; Current Capabilities and Future Upgrade Plans of the C-17 Data Rack; Intelligent Data Mining Capabilities as Applied to Integrated Vehicle Health Management; STARS Flight Demonstration No. 2 IP Data Formatter; Space-Based Telemetry and Range Safety (STARS) Flight Demonstration No. 2 Range User Flight Test Results; Aerodynamic Effects of the Quiet Spike(tm) on an F-15B Aircraft; F-15 Intelligent Flight Controls-Increased Destabilization Failure; F-15 Integrated Resilient Aircraft Control (IRAC) Improved Adaptive Controller; Aeroelastic Analysis of the Ikhana/Fire Pod System; Ikhana: Western States Fire Missions Utilizing the Ames Research Center Fire Sensor; Ikhana: Fiber-Optic Wing Shape Sensors; Ikhana: ARTS III; SOFIA Closed-Door Flutter Envelope Flight Testing; F-15B Quiet Spike(TM) Aeroservoelastic Flight Test Data Analysis; and UAVSAR Platform Precision Autopilot Flight Results.
Analysis of airfoil leading edge separation bubbles
NASA Technical Reports Server (NTRS)
Carter, J. E.; Vatsa, V. N.
1982-01-01
A local inviscid-viscous interaction technique was developed for the analysis of low speed airfoil leading edge transitional separation bubbles. In this analysis an inverse boundary layer finite difference analysis is solved iteratively with a Cauchy integral representation of the inviscid flow which is assumed to be a linear perturbation to a known global viscous airfoil analysis. Favorable comparisons with data indicate the overall validity of the present localized interaction approach. In addition numerical tests were performed to test the sensitivity of the computed results to the mesh size, limits on the Cauchy integral, and the location of the transition region.
NASA Technical Reports Server (NTRS)
Ko, W. L.; Schuster, L. S.
1983-01-01
This paper concerns the transient dynamic analysis of the B-52 aircraft carrying the Space Shuttle solid-rocket booster drop-test vehicle (SRB/DTV). The NASA structural analysis (NASTRAN) finite-element computer program was used in the analysis. The B-52 operating conditions considered for analysis were (1) landing and (2) braking on aborted takeoff runs. The transient loads for the B-52 pylon front and rear hooks were calculated. The results can be used to establish the safe maneuver envelopes for the B-52 carrying the SRB/DTV in landings and brakings.
Larson, Nicholas B; McDonnell, Shannon; Cannon Albright, Lisa; Teerlink, Craig; Stanford, Janet; Ostrander, Elaine A; Isaacs, William B; Xu, Jianfeng; Cooney, Kathleen A; Lange, Ethan; Schleutker, Johanna; Carpten, John D; Powell, Isaac; Bailey-Wilson, Joan E; Cussenot, Olivier; Cancel-Tassin, Geraldine; Giles, Graham G; MacInnis, Robert J; Maier, Christiane; Whittemore, Alice S; Hsieh, Chih-Lin; Wiklund, Fredrik; Catalona, William J; Foulkes, William; Mandal, Diptasri; Eeles, Rosalind; Kote-Jarai, Zsofia; Ackerman, Michael J; Olson, Timothy M; Klein, Christopher J; Thibodeau, Stephen N; Schaid, Daniel J
2017-05-01
Next-generation sequencing technologies have afforded unprecedented characterization of low-frequency and rare genetic variation. Due to low power for single-variant testing, aggregative methods are commonly used to combine observed rare variation within a single gene. Causal variation may also aggregate across multiple genes within relevant biomolecular pathways. Kernel-machine regression and adaptive testing methods for aggregative rare-variant association testing have been demonstrated to be powerful approaches for pathway-level analysis, although these methods tend to be computationally intensive at high-variant dimensionality and require access to complete data. An additional analytical issue in scans of large pathway definition sets is multiple testing correction. Gene set definitions may exhibit substantial genic overlap, and the impact of the resultant correlation in test statistics on Type I error rate control for large agnostic gene set scans has not been fully explored. Herein, we first outline a statistical strategy for aggregative rare-variant analysis using component gene-level linear kernel score test summary statistics as well as derive simple estimators of the effective number of tests for family-wise error rate control. We then conduct extensive simulation studies to characterize the behavior of our approach relative to direct application of kernel and adaptive methods under a variety of conditions. We also apply our method to two case-control studies, respectively, evaluating rare variation in hereditary prostate cancer and schizophrenia. Finally, we provide open-source R code for public use to facilitate easy application of our methods to existing rare-variant analysis results. © 2017 WILEY PERIODICALS, INC.
Bisoffi, Zeno; Sirima, Sodiomon B; Meheus, Filip; Lodesani, Claudia; Gobbi, Federico; Angheben, Andrea; Tinto, Halidou; Neya, Bouma; Van den Ende, Klara; Romeo, Annalisa; Van den Ende, Jef
2011-08-04
Malaria rapid diagnostic tests (RDTs) have generally been found reliable and cost-effective. In Burkina Faso, the adherence of prescribers to the negative test result was found to be poor. Moreover, the test accuracy for malaria-attributable fever (MAF) is not the same as for malaria infection. This paper aims at determining the costs and benefits of two competing strategies for the management of MAF: presumptive treatment for all or use of RDTs. A cost benefit analysis was carried out using a decision tree, based on data previously obtained, including a randomized controlled trial (RCT) recruiting 852 febrile patients during the dry season and 1,317 in the rainy season. Cost and benefit were calculated using both the real adherence found by the RCT and assuming an ideal adherence of 90% with the negative result. The main parameters were submitted to sensitivity analysis. At real adherence, the test-based strategy was dominated. Assuming ideal adherence, at the value of 525 € for a death averted, the total cost of managing 1,000 febrile children was 1,747 vs. 1,862 € in the dry season and 1,372 vs. 2,138 in the rainy season for the presumptive vs. the test-based strategy. For adults it was 2,728 vs. 1,983 and 2,604 vs. 2,225, respectively. At the subsidized policy adopted locally, assuming ideal adherence, the RDT would be the winning strategy for adults in both seasons and for children in the dry season.At sensitivity analysis, the factors most influencing the choice of the better strategy were the value assigned to a death averted and the proportion of potentially severe NMFI treated with antibiotics in patients with false positive RDT results. The test-based strategy appears advantageous for adults if a satisfactory adherence could be achieved. For children the presumptive strategy remains the best choice for a wide range of scenarios. For RDTs to be preferred, a positive result should not influence the decision to treat a potentially severe NMFI with antibiotics. In the rainy season the presumptive strategy always remains the better choice for children.
Emerencia, Ando C; Bos, Elisabeth H; Rosmalen, Judith GM; Riese, Harriëtte; Aiello, Marco; Sytema, Sjoerd; de Jonge, Peter
2015-01-01
Background Health promotion can be tailored by combining ecological momentary assessments (EMA) with time series analysis. This combined method allows for studying the temporal order of dynamic relationships among variables, which may provide concrete indications for intervention. However, application of this method in health care practice is hampered because analyses are conducted manually and advanced statistical expertise is required. Objective This study aims to show how this limitation can be overcome by introducing automated vector autoregressive modeling (VAR) of EMA data and to evaluate its feasibility through comparisons with results of previously published manual analyses. Methods We developed a Web-based open source application, called AutoVAR, which automates time series analyses of EMA data and provides output that is intended to be interpretable by nonexperts. The statistical technique we used was VAR. AutoVAR tests and evaluates all possible VAR models within a given combinatorial search space and summarizes their results, thereby replacing the researcher’s tasks of conducting the analysis, making an informed selection of models, and choosing the best model. We compared the output of AutoVAR to the output of a previously published manual analysis (n=4). Results An illustrative example consisting of 4 analyses was provided. Compared to the manual output, the AutoVAR output presents similar model characteristics and statistical results in terms of the Akaike information criterion, the Bayesian information criterion, and the test statistic of the Granger causality test. Conclusions Results suggest that automated analysis and interpretation of times series is feasible. Compared to a manual procedure, the automated procedure is more robust and can save days of time. These findings may pave the way for using time series analysis for health promotion on a larger scale. AutoVAR was evaluated using the results of a previously conducted manual analysis. Analysis of additional datasets is needed in order to validate and refine the application for general use. PMID:26254160
Experimental and simulation flow rate analysis of the 3/2 directional pneumatic valve
NASA Astrophysics Data System (ADS)
Blasiak, Slawomir; Takosoglu, Jakub E.; Laski, Pawel A.; Pietrala, Dawid S.; Zwierzchowski, Jaroslaw; Bracha, Gabriel; Nowakowski, Lukasz; Blasiak, Malgorzata
The work includes a study on the comparative analysis of two test methods. The first method - numerical method, consists in determining the flow characteristics with the use of ANSYS CFX. A modeled poppet directional valve 3/2 3D CAD software - SolidWorks was used for this purpose. Based on the solid model that was developed, simulation studies of the air flow through the way valve in the software for computational fluid dynamics Ansys CFX were conducted. The second method - experimental, entailed conducting tests on a specially constructed test stand. The comparison of the test results obtained on the basis of both methods made it possible to determine the cross-correlation. High compatibility of the results confirms the usefulness of the numerical procedures. Thus, they might serve to determine the flow characteristics of directional valves as an alternative to a costly and time-consuming test stand.
Extending LMS to Support IRT-Based Assessment Test Calibration
NASA Astrophysics Data System (ADS)
Fotaris, Panagiotis; Mastoras, Theodoros; Mavridis, Ioannis; Manitsaris, Athanasios
Developing unambiguous and challenging assessment material for measuring educational attainment is a time-consuming, labor-intensive process. As a result Computer Aided Assessment (CAA) tools are becoming widely adopted in academic environments in an effort to improve the assessment quality and deliver reliable results of examinee performance. This paper introduces a methodological and architectural framework which embeds a CAA tool in a Learning Management System (LMS) so as to assist test developers in refining items to constitute assessment tests. An Item Response Theory (IRT) based analysis is applied to a dynamic assessment profile provided by the LMS. Test developers define a set of validity rules for the statistical indices given by the IRT analysis. By applying those rules, the LMS can detect items with various discrepancies which are then flagged for review of their content. Repeatedly executing the aforementioned procedure can improve the overall efficiency of the testing process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRosier, R.
1984-07-01
This volume of the report gives emission results from field tests of a crude-oil process heater burning a combination of oil and refinery gas. The heater had been modified by adding a system for injecting secondary air to reduce NOx emissions. One test was conducted with the staged air system (low NOx), and the other, without (baseline). Tests included continuous monitoring of flue gas emissions and source assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of the samples utilizing gas chromatography (GC), infrared spectrometry (IR), gas chromatography/mass spectroscopy (GC/MS), and low resolution mass spectrometry (SSMS)more » for trace metals. LRMS analysis suggested the presence of eight compound categories in the organic emissions during the baseline test and four in the low-NOx test.« less
In-Flight System Identification
NASA Technical Reports Server (NTRS)
Morelli, Eugene A.
1998-01-01
A method is proposed and studied whereby the system identification cycle consisting of experiment design and data analysis can be repeatedly implemented aboard a test aircraft in real time. This adaptive in-flight system identification scheme has many advantages, including increased flight test efficiency, adaptability to dynamic characteristics that are imperfectly known a priori, in-flight improvement of data quality through iterative input design, and immediate feedback of the quality of flight test results. The technique uses equation error in the frequency domain with a recursive Fourier transform for the real time data analysis, and simple design methods employing square wave input forms to design the test inputs in flight. Simulation examples are used to demonstrate that the technique produces increasingly accurate model parameter estimates resulting from sequentially designed and implemented flight test maneuvers. The method has reasonable computational requirements, and could be implemented aboard an aircraft in real time.
Two-Dimensional Finite Element Ablative Thermal Response Analysis of an Arcjet Stagnation Test
NASA Technical Reports Server (NTRS)
Dec, John A.; Laub, Bernard; Braun, Robert D.
2011-01-01
The finite element ablation and thermal response (FEAtR, hence forth called FEAR) design and analysis program simulates the one, two, or three-dimensional ablation, internal heat conduction, thermal decomposition, and pyrolysis gas flow of thermal protection system materials. As part of a code validation study, two-dimensional axisymmetric results from FEAR are compared to thermal response data obtained from an arc-jet stagnation test in this paper. The results from FEAR are also compared to the two-dimensional axisymmetric computations from the two-dimensional implicit thermal response and ablation program under the same arcjet conditions. The ablating material being used in this arcjet test is phenolic impregnated carbon ablator with an LI-2200 insulator as backup material. The test is performed at the NASA, Ames Research Center Interaction Heating Facility. Spatially distributed computational fluid dynamics solutions for the flow field around the test article are used for the surface boundary conditions.
FIRE TEST AND HEAT ANALYSIS FOR STEEL-CONCRETE COMPOSITE MEMBER WITH FIREPROOF BOARD
NASA Astrophysics Data System (ADS)
Nakai, Akihiro; Kiyomiya, Osamu
Composite members made of steel and concrete have been widely adopted for undersea tunnels. Since steel plates are exposed to the internal side of the tunnel, vehicle fire countermeasures are required. First, the RABT heating test for the composite members without the fireproof board was executed, and the damage and the deterioration of the internal concrete were examined. Next, the transmission mechanism of heat in the air layer between the fireproof board and the steel was aloso examined by the element test to mesure the heat flow by the radiation, convection, and the conduction. Furthermore, the RABT heating test with fireproof board was executed, and the internal temperature was measured and the effect of the air layer was confirmed. Finally, validity of the proposed analytical model was confirmed by comparing the heat analysis results with the heat tests results.
FABRIC FILTER MODEL SENSITIVITY ANALYSIS
The report gives results of a series of sensitivity tests of a GCA fabric filter model, as a precursor to further laboratory and/or field tests. Preliminary tests had shown good agreement with field data. However, the apparent agreement between predicted and actual values was bas...
Correlation Between Ultrasonic Nondestructive Inspection and Wheel Test of 34 Retreaded Tires
DOT National Transportation Integrated Search
1979-11-01
The report covers a test in which 34 retread tires were inspected using reflection ultrasound nondestructive inspection, wheel tested and then subjected to failure analysis by sectioning. The results demonstrate for the first time the ability of ultr...
Flight Test Evaluation and Analysis of an Optical IR PWI System
DOT National Transportation Integrated Search
1972-06-01
This report documents the flight test results of the optical : infrared (IR) Pilot Warning Instrument (PWI) system conducted by the : Transportation Systems Center as part of an FAA/NASA PWI development : program. The test program is described and th...
Borehole flowmeter logging for the accurate design and analysis of tracer tests.
Basiricò, Stefano; Crosta, Giovanni B; Frattini, Paolo; Villa, Alberto; Godio, Alberto
2015-04-01
Tracer tests often give ambiguous interpretations that may be due to the erroneous location of sampling points and/or the lack of flow rate measurements through the sampler. To obtain more reliable tracer test results, we propose a methodology that optimizes the design and analysis of tracer tests in a cross borehole mode by using vertical borehole flow rate measurements. Experiments using this approach, herein defined as the Bh-flow tracer test, have been performed by implementing three sequential steps: (1) single-hole flowmeter test, (2) cross-hole flowmeter test, and (3) tracer test. At the experimental site, core logging, pumping tests, and static water-level measurements were previously carried out to determine stratigraphy, fracture characteristics, and bulk hydraulic conductivity. Single-hole flowmeter testing makes it possible to detect the presence of vertical flows as well as inflow and outflow zones, whereas cross-hole flowmeter testing detects the presence of connections along sets of flow conduits or discontinuities intercepted by boreholes. Finally, the specific pathways and rates of groundwater flow through selected flowpaths are determined by tracer testing. We conclude that the combined use of single and cross-borehole flowmeter tests is fundamental to the formulation of the tracer test strategy and interpretation of the tracer test results. © 2014, National Ground Water Association.
Distributed analysis functional testing using GangaRobot in the ATLAS experiment
NASA Astrophysics Data System (ADS)
Legger, Federica; ATLAS Collaboration
2011-12-01
Automated distributed analysis tests are necessary to ensure smooth operations of the ATLAS grid resources. The HammerCloud framework allows for easy definition, submission and monitoring of grid test applications. Both functional and stress test applications can be defined in HammerCloud. Stress tests are large-scale tests meant to verify the behaviour of sites under heavy load. Functional tests are light user applications running at each site with high frequency, to ensure that the site functionalities are available at all times. Success or failure rates of these tests jobs are individually monitored. Test definitions and results are stored in a database and made available to users and site administrators through a web interface. In this work we present the recent developments of the GangaRobot framework. GangaRobot monitors the outcome of functional tests, creates a blacklist of sites failing the tests, and exports the results to the ATLAS Site Status Board (SSB) and to the Service Availability Monitor (SAM), providing on the one hand a fast way to identify systematic or temporary site failures, and on the other hand allowing for an effective distribution of the work load on the available resources.
The DOE ETV-1 Electric Test Vehicle. Phase 3: Performance Testing and system evaluation
NASA Technical Reports Server (NTRS)
Kurtz, D.
1981-01-01
Engineering tests were conducted in order to characterize overall system performance and component efficiencies within the system environment. A dynamometer was used in order to minimize the ambient effects and large uncertainties present in track testing. Extensive test requirements were defined and procedures were carefully controlled in order to maintain a high degree of credibility. Limited track testing was performed in order to corroborate the dynamometer results. Test results include an energy flow analysis through the major subsystems and incorporate the aerodynamic and rolling losses under cyclic and various steady speed conditions. The major output from all relevant dynamometer and track tests is also included.
NASA Technical Reports Server (NTRS)
Perez, Jose G.; Parks, Russel, A.; Lazor, Daniel R.
2012-01-01
The slosh dynamics of propellant tanks can be represented by an equivalent mass-pendulum-dashpot mechanical model. The parameters of this equivalent model, identified as slosh mechanical model parameters, are slosh frequency, slosh mass, and pendulum hinge point location. They can be obtained by both analysis and testing for discrete fill levels. Anti-slosh baffles are usually needed in propellant tanks to control the movement of the fluid inside the tank. Lateral slosh testing, involving both random excitation testing and free-decay testing, are performed to validate the slosh mechanical model parameters and the damping added to the fluid by the anti-slosh baffles. Traditional modal analysis procedures were used to extract the parameters from the experimental data. Test setup of sub-scale tanks will be described. A comparison between experimental results and analysis will be presented.
Integrated Data Collection Analysis (IDCA) Program - NaClO 3/Icing Sugar
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of NaClO 3 and icing sugar—NaClO 3/icing sugar mixture. The mixture was found to: be more sensitive than RDX but less sensitive than PETN in impact testing (180-grit sandpaper); be more sensitive than RDX and about the same sensitivity as PETN in BAM fiction testing; be less sensitive than RDX and PETN except for one participant found themore » mixture more sensitive than PETN in ABL ESD testing; and to have one to three exothermic features with the lowest temperature event occurring at ~ 160°C always observed in thermal testing. Variations in testing parameters also affected the sensitivity.« less
Lavergne, Céline; Jeison, David; Ortega, Valentina; Chamy, Rolando; Donoso-Bravo, Andrés
2018-09-15
An important variability in the experimental results in anaerobic digestion lab test has been reported. This study presents a meta-analysis coupled with multivariate analysis aiming to assess the impact of this experimental variability in batch and continuous operation at mesophilic and thermophilic anaerobic digestion of waste activated sludge. An analysis of variance showed that there was no significant difference between mesophilic and thermophilic conditions in both continuous and batch conditions. Concerning the operation mode, the values of methane yield were significantly higher in batch experiment than in continuous reactors. According to the PCA, for both cases, the methane yield is positive correlated to the temperature rises. Interestingly, in the batch experiments, the higher the volatile solids in the substrate was, the lowest was the methane production, which is correlated to experimental flaws when setting up those tests. In continuous mode, unlike the batch test, the methane yield is strongly (positively) correlated to the organic content of the substrate. Experimental standardization, above all, in batch conditions are urgently necessary or move to continuous experiments for reporting results. The modeling can also be a source of disturbance in batch test. Copyright © 2018 Elsevier Ltd. All rights reserved.
Construct exploit constraint in crash analysis by bypassing canary
NASA Astrophysics Data System (ADS)
Huang, Ning; Huang, Shuguang; Huang, Hui; Chang, Chao
2017-08-01
Selective symbolic execution is a common program testing technology. Developed on the basis of it, some crash analysis systems are often used to test the fragility of the program by constructing exploit constraints, such as CRAX. From the study of crash analysis based on symbolic execution, this paper find that this technology cannot bypass the canary stack protection mechanisms. This paper makes the improvement uses the API hook in Linux. Experimental results show that the use of API hook can effectively solve the problem that crash analysis cannot bypass the canary protection.
Random left censoring: a second look at bone lead concentration measurements
NASA Astrophysics Data System (ADS)
Popovic, M.; Nie, H.; Chettle, D. R.; McNeill, F. E.
2007-09-01
Bone lead concentrations measured in vivo by x-ray fluorescence (XRF) are subjected to left censoring due to limited precision of the technique at very low concentrations. In the analysis of bone lead measurements, inverse variance weighting (IVW) of measurements is commonly used to estimate the mean of a data set and its standard error. Student's t-test is used to compare the IVW means of two sets, testing the hypothesis that the two sets are from the same population. This analysis was undertaken to assess the adequacy of IVW in the analysis of bone lead measurements or to confirm the results of IVW using an independent approach. The rationale is provided for the use of methods of survival data analysis in the study of XRF bone lead measurements. The procedure is provided for bone lead data analysis using the Kaplan-Meier and Nelson-Aalen estimators. The methodology is also outlined for the rank tests that are used to determine whether two censored sets are from the same population. The methods are applied on six data sets acquired in epidemiological studies. The estimated parameters and test statistics were compared with the results of the IVW approach. It is concluded that the proposed methods of statistical analysis can provide valid inference about bone lead concentrations, but the computed parameters do not differ substantially from those derived by the more widely used method of IVW.
NASA Technical Reports Server (NTRS)
Smith, D. R.; Leslie, F. W.
1984-01-01
The Purdue Regional Objective Analysis of the Mesoscale (PROAM) is a successive correction type scheme for the analysis of surface meteorological data. The scheme is subjected to a series of experiments to evaluate its performance under a variety of analysis conditions. The tests include use of a known analytic temperature distribution to quantify error bounds for the scheme. Similar experiments were conducted using actual atmospheric data. Results indicate that the multiple pass technique increases the accuracy of the analysis. Furthermore, the tests suggest appropriate values for the analysis parameters in resolving disturbances for the data set used in this investigation.
Applications of Automation Methods for Nonlinear Fracture Test Analysis
NASA Technical Reports Server (NTRS)
Allen, Phillip A.; Wells, Douglas N.
2013-01-01
Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.
[Value of the tritium test for determining the fat content in the body of rats].
Pisarchuk, K L
1990-01-01
An indirect method for estimation of the fat percentage in the animal organism, a tritium test, was studied on laboratory male rats aged 4 and 12 months. Results obtained from the tritium test and direct chemical analysis were compared. With age a mean absolute error of the tritium test increased (from 1 to 8%) as against actual values of the water and fat percentage in the organism obtained by a direct chemical analysis. The data obtained testify to the relative insolvency of the tritium test, as well as the necessity to carry additional investigations in order to obtain adequate data.
Multi-Column Xe/Kr Separation with AgZ-PAN and HZ-PAN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greenhalgh, Mitchell Randy; Garn, Troy Gerry; Welty, Amy Keil
Previous multi-column xenon/krypton separation tests have demonstrated the capability of separating xenon from krypton in a mixed gas feed stream. The results of this initial testing with AgZ-PAN and HZ-PAN indicated that an excellent separation of xenon from krypton could be achieved. Building upon these initial results, a series of additional multi-column testing were performed in FY-16. The purpose of this testing was to scale up the sorbent beds, test a different composition of feed gas and attempt to improve the accuracy of the analysis of the individual capture columns’ compositions. Two Stirling coolers were installed in series to performmore » this testing. The use of the coolers instead of the cryostat provided two desired improvements, 1) removal of the large dilution due to the internal volume of the cryostat adsorption chamber, and 2) ability to increase the sorbent bed size for scale-up. The AgZ-PAN sorbent, due to its xenon selectivity, was loaded in the first column to capture the xenon while allowing the krypton to flow through and be routed to a second column containing the HZ-PAN for capture and analysis. The gases captured on both columns were sampled with evacuated sample bombs and subsequently analyzed via GC-MS for both krypton and xenon. The results of these tests can be used to develop the scope of future testing and analysis using this test bed for demonstrating the capture and separation of xenon and krypton using sorbents, for demonstrating desorption and regeneration of the sorbents, and for determining compositions of the desorbed gases. They indicate a need for future desorption studies in order to better quantify co-adsorbed species and final krypton purity.« less
NASA Astrophysics Data System (ADS)
Runnova, Anastasiya; Zhuravlev, Maxim; Kulanin, Roman; Protasov, Pavel; Efremova, Tatiana
2018-04-01
In this paper we found a correlation between the characteristics of a person revealed in classical psychological testing on the basis of Schulte tables, and its neurophysiological features of the functioning of the brain obtained from the time-frequency analysis of EEG. The results obtained are interesting from the point of view of the choice of training strategies for a particular individual. We believe that the obtained results are of interest for fundamental science and applied works of psychological testing and diagnostics. The study of such forming strategies on EEG data can be automated and do not require the work of highly skilled psychologists.
NASA Technical Reports Server (NTRS)
Hulka, James R.; Jones, G. W.
2010-01-01
Liquid rocket engines using oxygen and methane propellants are being considered by the National Aeronautics and Space Administration (NASA) for in-space vehicles. This propellant combination has not been previously used in flight-qualified engine systems, so limited test data and analysis results are available at this stage of early development. NASA has funded several hardware-oriented programs with oxygen and methane propellants over the past several years with the Propulsion and Cryogenic Advanced Development (PCAD) project, under the Exploration Technology Development Program. As part of this effort, NASA Marshall Space Flight Center has conducted combustion, performance, and combustion stability analyses of several of the configurations on these programs. This paper summarizes these analyses. Test and analysis results of impinging and coaxial element injectors using liquid oxygen and liquid methane propellants are included. Several cases with gaseous methane are included for reference. Several different thrust chamber configurations have been modeled, including thrust chambers with multi-element like-on-like and swirl coax element injectors tested at NASA MSFC, and a unielement chamber with shear and swirl coax injectors tested at The Pennsylvania State University. Configurations were modeled with two one-dimensional liquid rocket combustion analysis codes, the Rocket Combustor Interaction Design and Analysis (ROCCID), and the Coaxial Injector Combustion Model (CICM). Significant effort was applied to show how these codes can be used to model combustion and performance with oxygen/methane propellants a priori, and what anchoring or calibrating features need to be applied or developed in the future. This paper describes the test hardware configurations, presents the results of all the analyses, and compares the results from the two analytical methods.
NASA Technical Reports Server (NTRS)
Hulka, J. R.; Jones, G. W.
2010-01-01
Liquid rocket engines using oxygen and methane propellants are being considered by the National Aeronautics and Space Administration (NASA) for in-space vehicles. This propellant combination has not been previously used in a flight-qualified engine system, so limited test data and analysis results are available at this stage of early development. NASA has funded several hardware-oriented activities with oxygen and methane propellants over the past several years with the Propulsion and Cryogenic Advanced Development (PCAD) project, under the Exploration Technology Development Program. As part of this effort, the NASA Marshall Space Flight Center has conducted combustion, performance, and combustion stability analyses of several of the configurations. This paper summarizes the analyses of combustion and performance as a follow-up to a paper published in the 2008 JANNAF/LPS meeting. Combustion stability analyses are presented in a separate paper. The current paper includes test and analysis results of coaxial element injectors using liquid oxygen and liquid methane or gaseous methane propellants. Several thrust chamber configurations have been modeled, including thrust chambers with multi-element swirl coax element injectors tested at the NASA MSFC, and a uni-element chamber with shear and swirl coax injectors tested at The Pennsylvania State University. Configurations were modeled with two one-dimensional liquid rocket combustion analysis codes, the Rocket Combustor Interaction Design and Analysis (ROCCID), and the Coaxial Injector Combustion Model (CICM). Significant effort was applied to show how these codes can be used to model combustion and performance with oxygen/methane propellants a priori, and what anchoring or calibrating features need to be applied or developed in the future. This paper describes the test hardware configurations, presents the results of all the analyses, and compares the results from the two analytical methods
Screening for colon cancer: A test for occult blood.
Khakimov, N; Khasanova, G; Ershova, K; Gibadullina, L; Vetkina, T; Lobisheva, G; Chumakova, A
2015-01-01
The relevance of the problem of colorectal cancer (CRC) is evident because of extremely high morbidity and mortality rates, associated with this disease. CRC is mostly diagnosed only at very advanced stages. The reduction of mortality can be achieved by the popularization of screening-methods for early identification of CRC and adenomatous polyps of the colon, which are proved to be precancerous condition. Fecal occult blood test is a well-known method of screening for CRC. The advantages of this method when compared, for example, with colonoscopy are its simplicity and cost-effectiveness.Two techniques are usually used for detection of occult blood in the stool: Hemoccult (Guaiac) test and immunochemical test for hemoglobin. There is no consensus among researchers regarding the validity of these tests for the diagnosis of colorectal cancer. For example, J.S. Mandel (1996) notes 60% sensitivity of Guaiac-test for the detection of the early forms of colorectal cancer, while O.I. Kit (2014) suggets that it is not higher than 30%. There are also various opinions about specificity of these two tests. To review the literature on the validity of the fecal occult blood tests for the diagnosis of CRC. We looked for articles (electronic versions) available for free in the full-text versions, published from June 1, 1990 to December 31, 2014 in Russian or English. The following databases were used for search: E-LIBRARY; Cochrane; MEDLINE; EMBASE; Google search. Only original research papers were analyzed. Literature reviews or systematic reviews were not taken for analyses. 1) use of Guaiac and/or immunochemical fecal occult blood test as screening-tests for the detection of colorectal cancer and/or colon polyps (1 cm or more in diameter) in people older than 45 years; 2) comparing of results with the results of colonoscopy (colonoscopy is counted by majority of the authors as a "gold standard" for the diagnosis of CRC and adenomatous polyps). Initial keyword search returned 803 000 results, of which 449 sources were selected. After reading the abstracts, 29 articles that met inclusion criteria were kept. 10 other articles were excluded after that because they did not contain enough data for extraction or did not contain a control group. At the final step 19 articles were used for meta-analysis.Forest plot and Rock curve, which were developed with inclusion of the data from all studies, showed heterogeneity of the data. Additional analyzes were performed in subgroups with different diagnoses and various tests.The sensitivity of the Guaiac test for the diagnosis of colorectal cancer varied from 0.13 to 1.00, and specificity - from 0.69 to 0.99. The sensitivity of the immunochemical test for the diagnosis of CRC ranged from 0.42 to 0.94 with specificity ranging from 0.40 to 1.00.The sensitivity of the Guaiac test for the diagnosis of the colon polyps was between 0.05 and 0.69, and its specificity - from 0.67 to 0.98. The sensitivity of the immunochemical test for the diagnosis of polyps was from 0.24 to 0.75, and its specificity - from 0.40 to 0.97.Bivariate analysis of the validity of Guaiac test and immunochemical method for the diagnosis of colorectal cancer showed better results for the immunochemical test compared to Guaiac test. The tests showed very similar results when used for the diagnosis of polyposis. Bivariate analysis, comparing the validity of tests for the diagnosis of colorectal cancer versus polyposis demonstrated better results for CRC.Multivariate analysis of the validity of the Guaiac and immunochemical tests for the diagnosis of colorectal cancer and polyps also showed better results for detection of colorectal cancer compared with the polyps for both tests. At the same time the highest validity for the diagnosis of CRC was demonstrated for immunochemical analysis. 1. The sensitivity of the Guaiac test for occult blood in stool is lower than its specificity.2. Broad dispersion of the validity characteristics of the fecal occult blood tests was observed.3. The validity of tests for occult blood was higher when they were used for detection of colorectal cancer than of colon polyposis.4. The highest validity rate has been demonstrated for the immunochemical test when it was used for colon cancer screening.
Simulation and Analysis of Converging Shock Wave Test Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramsey, Scott D.; Shashkov, Mikhail J.
2012-06-21
Results and analysis pertaining to the simulation of the Guderley converging shock wave test problem (and associated code verification hydrodynamics test problems involving converging shock waves) in the LANL ASC radiation-hydrodynamics code xRAGE are presented. One-dimensional (1D) spherical and two-dimensional (2D) axi-symmetric geometric setups are utilized and evaluated in this study, as is an instantiation of the xRAGE adaptive mesh refinement capability. For the 2D simulations, a 'Surrogate Guderley' test problem is developed and used to obviate subtleties inherent to the true Guderley solution's initialization on a square grid, while still maintaining a high degree of fidelity to the originalmore » problem, and minimally straining the general credibility of associated analysis and conclusions.« less
Leimu, Roosa; Koricheva, Julia
2004-01-01
Temporal changes in the magnitude of research findings have recently been recognized as a general phenomenon in ecology, and have been attributed to the delayed publication of non-significant results and disconfirming evidence. Here we introduce a method of cumulative meta-analysis which allows detection of both temporal trends and publication bias in the ecological literature. To illustrate the application of the method, we used two datasets from recently conducted meta-analyses of studies testing two plant defence theories. Our results revealed three phases in the evolution of the treatment effects. Early studies strongly supported the hypothesis tested, but the magnitude of the effect decreased considerably in later studies. In the latest studies, a trend towards an increase in effect size was observed. In one of the datasets, a cumulative meta-analysis revealed publication bias against studies reporting disconfirming evidence; such studies were published in journals with a lower impact factor compared to studies with results supporting the hypothesis tested. Correlation analysis revealed neither temporal trends nor evidence of publication bias in the datasets analysed. We thus suggest that cumulative meta-analysis should be used as a visual aid to detect temporal trends and publication bias in research findings in ecology in addition to the correlative approach. PMID:15347521
Altet-Gómez, N; De Souza-Galvao, M; Latorre, I; Milà, C; Jiménez, M A; Solsona, J; Cantos, A; Zamora, J J; Ruiz-Manzano, J; Ausina, V; Domínguez, J
2011-05-01
The aim of the present study was to compare the performance of the interferon (IFN)-γ tests (QuantiFERON®-TB Gold In-Tube (QFT-G-IT) and T-SPOT®.TB) with the tuberculin skin test (TST) in diagnosing tuberculosis (TB) infection in children, and to analyse discordant results. This was a prospective study including 98 children from contact-tracing studies and 68 children with TST indurations ≥ 5 mm recruited during public health screenings. Positive IFN-γ tests results were associated with risk of exposure (p<0.0001). T-SPOT.TB was positive in 11 (78.6%) out of 14 cases with active TB and QFT-G-IT in nine (64.3%) out of 14 cases. Sensitised T-cells against Mycobacterium avium were detected in six out of 12 children not vaccinated with bacille Calmette-Guérin (BCG), a TST induration 5-9 mm in diameter and both IFN-γ tests negative. In concordant IFN-γ tests results, a positive correlation was found (p = 0.0001) between the number of responding cells and the amount of IFN-γ released. However, in discordant IFN-γ tests results this correlation was negative (p = 0.371): an increase in the number of spot-forming cells correlated with a decrease in the amount of IFN-γ released. The use of IFN-γ tests is helpful for the diagnosis of TB infection, avoiding cross-reactions with BCG immunisation and nontuberculous mycobacterial infections. The analysis of highly discordant results requires further investigation to elucidate possible clinical implications.
NASA Technical Reports Server (NTRS)
Phillips, Edward P.
1989-01-01
An experimental Round Robin on the measurement of the opening load in fatigue crack growth tests was conducted on Crack Closure Measurement and Analysis. The Round Robin evaluated the current level of consistency of opening load measurements among laboratories and to identify causes for observed inconsistency. Eleven laboratories participated in the testing of compact and middle-crack specimens. Opening-load measurements were made for crack growth at two stress-intensity factor levels, three crack lengths, and following an overload. All opening-load measurements were based on the analysis of specimen compliance data. When all of the results reported (from all participants, all measurement methods, and all data analysis methods) for a given test condition were pooled, the range of opening loads was very large--typically spanning the lower half of the fatigue loading cycle. Part of the large scatter in the reported opening-load results was ascribed to consistent differences in results produced by the various methods used to measure specimen compliance and to evaluate the opening load from the compliance data. Another significant portion of the scatter was ascribed to lab-to-lab differences in producing the compliance data when using nominally the same method of measurement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Hang Bae
A reliability testing was performed for the software of Shutdown(SDS) Computers for Wolsong Nuclear Power Plants Units 2, 3 and 4. profiles to the SDS Computers and compared the outputs with the predicted results generated by the oracle. Test softwares were written to execute the test automatically. Random test profiles were generated using analysis code. 11 refs., 1 fig.
Statistics Test Questions: Content and Trends
ERIC Educational Resources Information Center
Salcedo, Audy
2014-01-01
This study presents the results of the analysis of a group of teacher-made test questions for statistics courses at the university level. Teachers were asked to submit tests they had used in their previous two semesters. Ninety-seven tests containing 978 questions were gathered and classified according to the SOLO taxonomy (Biggs & Collis,…