Sample records for analytical reference glass

  1. A new basaltic glass microanalytical reference material for multiple techniques

    USGS Publications Warehouse

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only nominal compositional ranges for each element are given in the article.

  2. Comprehensive Isotopic and Elemental Analysis of a Multi-Oxide Glass By Multicollector ICP-MS in Isotope Substitution Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    v, Mitroshkov; JV, Ryan

    2016-04-07

    Multicollector ICP-MS was used to comprehensively analyze different types of isotopically-modified glass created in order to investigate the processes of glass corrosion in the water. The analytical methods were developed for the analyses of synthesized, isotopically-modified solid glass and the release of glass constituents upon contact with deionized water. To validate the methods, results from an acid digestion sample of the Analytical Reference Glass (ARG) showed good agreement when compared to data from multiple prior analyses on the same glass [Smith-1]. In this paper, we present the results of this comprehensive analysis from the acid digestion of six types ofmore » isotopically-modified glass and the release of glass constituents into water corrosion after one year of aqueous corrosion.« less

  3. An automated protocol for performance benchmarking a widefield fluorescence microscope.

    PubMed

    Halter, Michael; Bier, Elianna; DeRose, Paul C; Cooksey, Gregory A; Choquette, Steven J; Plant, Anne L; Elliott, John T

    2014-11-01

    Widefield fluorescence microscopy is a highly used tool for visually assessing biological samples and for quantifying cell responses. Despite its widespread use in high content analysis and other imaging applications, few published methods exist for evaluating and benchmarking the analytical performance of a microscope. Easy-to-use benchmarking methods would facilitate the use of fluorescence imaging as a quantitative analytical tool in research applications, and would aid the determination of instrumental method validation for commercial product development applications. We describe and evaluate an automated method to characterize a fluorescence imaging system's performance by benchmarking the detection threshold, saturation, and linear dynamic range to a reference material. The benchmarking procedure is demonstrated using two different materials as the reference material, uranyl-ion-doped glass and Schott 475 GG filter glass. Both are suitable candidate reference materials that are homogeneously fluorescent and highly photostable, and the Schott 475 GG filter glass is currently commercially available. In addition to benchmarking the analytical performance, we also demonstrate that the reference materials provide for accurate day to day intensity calibration. Published 2014 Wiley Periodicals Inc. Published 2014 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.

  4. Evaluation of new geological reference materials for uranium-series measurements: Chinese Geological Standard Glasses (CGSG) and macusanite obsidian.

    PubMed

    Denton, J S; Murrell, M T; Goldstein, S J; Nunn, A J; Amato, R S; Hinrichs, K A

    2013-10-15

    Recent advances in high-resolution, rapid, in situ microanalytical techniques present numerous opportunities for the analytical community, provided accurately characterized reference materials are available. Here, we present multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) uranium and thorium concentration and isotopic data obtained by isotope dilution for a suite of newly available Chinese Geological Standard Glasses (CGSG) designed for microanalysis. These glasses exhibit a range of compositions including basalt, syenite, andesite, and a soil. Uranium concentrations for these glasses range from ∼2 to 14 μg g(-1), Th/U weight ratios range from ∼4 to 6, (234)U/(238)U activity ratios range from 0.93 to 1.02, and (230)Th/(238)U activity ratios range from 0.98 to 1.12. Uranium and thorium concentration and isotopic data are also presented for a rhyolitic obsidian from Macusani, SE Peru (macusanite). This glass can also be used as a rhyolitic reference material, has a very low Th/U weight ratio (around 0.077), and is approximately in (238)U-(234)U-(230)Th secular equilibrium. The U-Th concentration data agree with but are significantly more precise than those previously measured. U-Th concentration and isotopic data agree within estimated errors for the two measurement techniques, providing validation of the two methods. The large (238)U-(234)U-(230)Th disequilibria for some of the glasses, along with the wide range in their chemical compositions and Th/U ratios should provide useful reference points for the U-series analytical community.

  5. GSD-1G and MPI-DING Reference Glasses for In Situ and Bulk Isotopic Determination

    USGS Publications Warehouse

    Jochum, K.P.; Wilson, S.A.; Abouchami, W.; Amini, M.; Chmeleff, J.; Eisenhauer, A.; Hegner, E.; Iaccheri, L.M.; Kieffer, B.; Krause, J.; McDonough, W.F.; Mertz-Kraus, R.; Raczek, I.; Rudnick, R.L.; Scholz, Donna K.; Steinhoefel, G.; Stoll, B.; Stracke, A.; Tonarini, S.; Weis, D.; Weis, U.; Woodhead, J.D.

    2011-01-01

    This paper contains the results of an extensive isotopic study of United States Geological Survey GSD-1G and MPI-DING reference glasses. Thirteen different laboratories were involved using high-precision bulk (TIMS, MC-ICP-MS) and microanalytical (LA-MC-ICP-MS, LA-ICP-MS) techniques. Detailed studies were performed to demonstrate the large-scale and small-scale homogeneity of the reference glasses. Together with previously published isotopic data from ten other laboratories, preliminary reference and information values as well as their uncertainties at the 95% confidence level were determined for H, O, Li, B, Si, Ca, Sr, Nd, Hf, Pb, Th and U isotopes using the recommendations of the International Association of Geoanalysts for certification of reference materials. Our results indicate that GSD-1G and the MPI-DING glasses are suitable reference materials for microanalytical and bulk analytical purposes. Ce document contient les r??sultats d'une importante ??tude isotopique des verres de r??f??rence USGS GSD-1G et MPI-DING. Treize laboratoires diff??rents ont particip?? au travers de techniques analytiques de haute pr??cision travaillant soit sur ??chantillon total (TIMS, MC-ICP-MS) soit par microanalyse ??in situ?? (LA-MC-ICP-MS, LA-ICP-MS). ?? 2010 The Authors. Geostandards and Geoanalytical Research ?? 2010 International Association of Geoanalysts.

  6. 21 CFR 172.133 - Dimethyl dicarbonate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... titration Reference electrode Glass electrode reagents Acetone, analytical-grade Solution of 1 N... sample (W) and dissolve in 100 mL acetone. Add accurately 25 mL of the 1 N diisobutylamine solution by... the diisobutylamine solution, always use the same pipette and wait for a further three drops to fall...

  7. Quantitative micro-Raman analysis of volcanic glasses: influence and correction of matrix effects

    NASA Astrophysics Data System (ADS)

    Di Muro, Andrea

    2014-05-01

    Micro-Raman spectroscopy, even though a very promising micro-analytical technique, is still not used to routinely quantify volatile elements dissolved in glasses. Following an original idea of Galeener and Mikkelsen (1981) for the quantification of hydroxyl (OH) in silica glass, several quantitative procedures have been recently proposed for the analysis of water, sulphur and carbon in natural glasses (obsidians, pumices, melt inclusions). The quantification of a single analyte requires the calibration of the correlation between the intensity I (height or area) of the related Raman band, normalized or not to a reference band RB, and the analyte concentration. For the analysis of alumino-silicate glasses, RB corresponds to one of the two main envelopes (LF and HF) related to the vibration of the glass network. Calibrations are linear, provided the increase in the analyte concentration does not dramatically affect RB intensity. Much attention has been paid to identify the most appropriate spectral treatment (spectra reduction; baseline subtraction; etc) to achieve accurate measurement of band intensities. I here show that the accuracy of Raman procedures for volatile quantification critically depends on the capability in predicting and in taking into account the influence of multiple matrix effects, which are often correlated with the average polymerization degree of the glass network. A general model has been developed to predict matrix effects affecting micro-Raman analysis of natural glasses. The specific and critical influence of iron redox state and pressure are discussed. The approach has been extensively validated for the study of melt inclusions and matrices spanning a broad range of compositions and dissolved volatile contents. References Analytical procedures Mercier, M, Di Muro, A., Métrich, N., Giordano, D., Belhadj, O., Mandeville, C.W. (2010) Spectroscopic analysis (FTIR, Raman) of water in mafic and intermediate glasses and glass inclusions. Geochimica et Cosmochimica Acta, 74, 5641-5656. Mercier, M., Di Muro, A., Giordano, D., Métrich, N.,Pichavant, M., Clocchiatti, R., Montagnac, G. (2009) The influence of glass polymerization and oxidation on micro-Raman water analysis in alumino-silicate glasses. Geochimica et Cosmochimica Acta, 73, 197-217 Di Muro, A., Métrich, N., Mercier, M., Giordano, D., Massare, D., Montagnac, G. (2009) Micro-Raman determination of iron redox state in dry natural glasses : application to peralkaline rhyolites and basalts. Chemical Geology (Special volume on experimental techniques for the study of hydrothermal fluids and silicate melts) 259:78-88. Di Muro A, Villemant B, Montagnac G, Scaillet B, Reynard B (2006) The influence of glass composition on the determination of water content and speciation by Raman spectrometry. Geochimica and Cosmochimica Acta, 70, 2868-2884 Di Muro A, Giordano D., Villemant B, Montagnac G, Romano C. (2006) Influence of composition and thermal history of volcanic glasses on water content determination by microRaman spectrometry. Applied Geochemistry (Special volume on developments in analytical geochemistry). 21, 802-812. Application Di Muro, A., Staudacher, T., Ferrazzini, V., Villemant, B., Besson, P., Garofalo, C. (2014) Tracking magma injection in the Piton de la Fournaise volcanic edifice after the 2007 Summit Caldera Collapse by Pele's Hair Composition. Chapman Special Volume on Hawaiian volcanoes, AGU Books. Ardia, P., Di Muro, A., Giordano, D., Massare, D., Sanchez-Valle, C., Schmidt, M.W. (2014) Densification mechanisms of haplogranite glasses as a function of water content and pressure based on density and Raman data. Under review, submitted to Geochimica et Cosmochimica Acta. Métrich, N, Allard, P., Aiuppa, A., Bani, P., Bertagnini, A., Belhadj, O., Di Muro, A., Garaebiti, E., Massare, D., Parello, F., Shinohara, H. (2011) Magma and volatile feeding of post-caldera Yasur volcanism and block resurgence in Tanna island (Vanuatu arc). Journal of Petrology, 52(6): 1077-1105. Williamson, B.J., Di Muro, A., Horwell, C.J., Spieler, O., Llewellin (2010) Injection of vesicular magma into an andesitic dome at the effusive-explosive transition. Earth and Planetary Science Letters, 295, 83-90. Metrich, N., Bertagnini, A., Di Muro, A. (2010) Conditions of magma storage, degassing and ascent at Stromboli : new insights into the volcano plumbing system with inferences on the eruptive dynamics. Journal of Petrology, 51, 603-6026. Arias A., Oddone M., Bigazzi G., Di Muro A., Principe C., Norelli P. (2006) New data for the characterisation of Milos obsidians. Journal of Radioanalytical and Nuclear Chemistry, 268, 371-386.

  8. The Geochemical Databases GEOROC and GeoReM - What's New?

    NASA Astrophysics Data System (ADS)

    Sarbas, B.; Jochum, K. P.; Nohl, U.; Weis, U.

    2017-12-01

    The geochemical databases GEOROC (http: georoc.mpch-mainz.gwdg.de) and GeoReM (http: georem.mpch-mainz.gwdg.de) are maintained by the Max Planck Institute for Chemistry in Mainz, Germany. Both online databases became crucial tools for geoscientists from different research areas. They are regularly upgraded by new tools and new data from recent publications obtained from a wide range of international journals. GEOROC is a collection of published analyses of volcanic rocks and mantle xenoliths. Since recently, data for plutonic rocks are added. The analyses include major and trace element concentrations, radiogenic and non-radiogenic isotope ratios as well as analytical ages for whole rocks, glasses, minerals and inclusions. Samples come from eleven geological settings and span the whole geological age scale from Archean to Recent. Metadata include, among others, geographic location, rock class and rock type, geological age, degree of alteration, analytical method, laboratory, and reference. The GEOROC web page allows selection of samples by geological setting, geography, chemical criteria, rock or sample name, and bibliographic criteria. In addition, it provides a large number of precompiled files for individual locations, minerals and rock classes. GeoReM is a database collecting information about reference materials of geological and environmental interest, such as rock powders, synthetic and natural glasses as well as mineral, isotopic, biological, river water and seawater reference materials. It contains published data and compilation values (major and trace element concentrations and mass fractions, radiogenic and stable isotope ratios). Metadata comprise, among others, uncertainty, analytical method and laboratory. Reference materials are important for calibration, method validation, quality control and to establish metrological traceability. GeoReM offers six different search strategies: samples or materials (published values), samples (GeoReM preferred values), chemical criteria, chemical criteria based on bibliography, bibliography, as well as methods and institutions.

  9. Analytical Plan for Roman Glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strachan, Denis M.; Buck, Edgar C.; Mueller, Karl T.

    Roman glasses that have been in the sea or underground for about 1800 years can serve as the independent “experiment” that is needed for validation of codes and models that are used in performance assessment. Two sets of Roman-era glasses have been obtained for this purpose. One set comes from the sunken vessel the Iulia Felix; the second from recently excavated glasses from a Roman villa in Aquileia, Italy. The specimens contain glass artifacts and attached sediment or soil. In the case of the Iulia Felix glasses quite a lot of analytical work has been completed at the University ofmore » Padova, but from an archaeological perspective. The glasses from Aquileia have not been so carefully analyzed, but they are similar to other Roman glasses. Both glass and sediment or soil need to be analyzed and are the subject of this analytical plan. The glasses need to be analyzed with the goal of validating the model used to describe glass dissolution. The sediment and soil need to be analyzed to determine the profile of elements released from the glass. This latter need represents a significant analytical challenge because of the trace quantities that need to be analyzed. Both pieces of information will yield important information useful in the validation of the glass dissolution model and the chemical transport code(s) used to determine the migration of elements once released from the glass. In this plan, we outline the analytical techniques that should be useful in obtaining the needed information and suggest a useful starting point for this analytical effort.« less

  10. Practical Considerations for Determination of Glass Transition Temperature of a Maximally Freeze Concentrated Solution.

    PubMed

    Pansare, Swapnil K; Patel, Sajal Manubhai

    2016-08-01

    Glass transition temperature is a unique thermal characteristic of amorphous systems and is associated with changes in physical properties such as heat capacity, viscosity, electrical resistance, and molecular mobility. Glass transition temperature for amorphous solids is referred as (T g), whereas for maximally freeze concentrated solution, the notation is (T g'). This article is focused on the factors affecting determination of T g' for application to lyophilization process design and frozen storage stability. Also, this review provides a perspective on use of various types of solutes in protein formulation and their effect on T g'. Although various analytical techniques are used for determination of T g' based on the changes in physical properties associated with glass transition, the differential scanning calorimetry (DSC) is the most commonly used technique. In this article, an overview of DSC technique is provided along with brief discussion on the alternate analytical techniques for T g' determination. Additionally, challenges associated with T g' determination, using DSC for protein formulations, are discussed. The purpose of this review is to provide a practical industry perspective on determination of T g' for protein formulations as it relates to design and development of lyophilization process and/or for frozen storage; however, a comprehensive review of glass transition temperature (T g, T g'), in general, is outside the scope of this work.

  11. Correlating tephras and cryptotephras using glass compositional analyses and numerical and statistical methods: Review and evaluation

    NASA Astrophysics Data System (ADS)

    Lowe, David J.; Pearce, Nicholas J. G.; Jorgensen, Murray A.; Kuehn, Stephen C.; Tryon, Christian A.; Hayward, Chris L.

    2017-11-01

    We define tephras and cryptotephras and their components (mainly ash-sized particles of glass ± crystals in distal deposits) and summarize the basis of tephrochronology as a chronostratigraphic correlational and dating tool for palaeoenvironmental, geological, and archaeological research. We then document and appraise recent advances in analytical methods used to determine the major, minor, and trace elements of individual glass shards from tephra or cryptotephra deposits to aid their correlation and application. Protocols developed recently for the electron probe microanalysis of major elements in individual glass shards help to improve data quality and standardize reporting procedures. A narrow electron beam (diameter ∼3-5 μm) can now be used to analyze smaller glass shards than previously attainable. Reliable analyses of 'microshards' (defined here as glass shards <32 μm in diameter) using narrow beams are useful for fine-grained samples from distal or ultra-distal geographic locations, and for vesicular or microlite-rich glass shards or small melt inclusions. Caveats apply, however, in the microprobe analysis of very small microshards (≤∼5 μm in diameter), where particle geometry becomes important, and of microlite-rich glass shards where the potential problem of secondary fluorescence across phase boundaries needs to be recognised. Trace element analyses of individual glass shards using laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS), with crater diameters of 20 μm and 10 μm, are now effectively routine, giving detection limits well below 1 ppm. Smaller ablation craters (<10 μm) can be subject to significant element fractionation during analysis, but the systematic relationship of such fractionation with glass composition suggests that analyses for some elements at these resolutions may be quantifiable. In undertaking analyses, either by microprobe or LA-ICP-MS, reference material data acquired using the same procedure, and preferably from the same analytical session, should be presented alongside new analytical data. In part 2 of the review, we describe, critically assess, and recommend ways in which tephras or cryptotephras can be correlated (in conjunction with other information) using numerical or statistical analyses of compositional data. Statistical methods provide a less subjective means of dealing with analytical data pertaining to tephra components (usually glass or crystals/phenocrysts) than heuristic alternatives. They enable a better understanding of relationships among the data from multiple viewpoints to be developed and help quantify the degree of uncertainty in establishing correlations. In common with other scientific hypothesis testing, it is easier to infer using such analysis that two or more tephras are different rather than the same. Adding stratigraphic, chronological, spatial, or palaeoenvironmental data (i.e. multiple criteria) is usually necessary and allows for more robust correlations to be made. A two-stage approach is useful, the first focussed on differences in the mean composition of samples, or their range, which can be visualised graphically via scatterplot matrices or bivariate plots coupled with the use of statistical tools such as distance measures, similarity coefficients, hierarchical cluster analysis (informed by distance measures or similarity or cophenetic coefficients), and principal components analysis (PCA). Some statistical methods (cluster analysis, discriminant analysis) are referred to as 'machine learning' in the computing literature. The second stage examines sample variance and the degree of compositional similarity so that sample equivalence or otherwise can be established on a statistical basis. This stage may involve discriminant function analysis (DFA), support vector machines (SVMs), canonical variates analysis (CVA), and ANOVA or MANOVA (or its two-sample special case, the Hotelling two-sample T2 test). Randomization tests can be used where distributional assumptions such as multivariate normality underlying parametric tests are doubtful. Compositional data may be transformed and scaled before being subjected to multivariate statistical procedures including calculation of distance matrices, hierarchical cluster analysis, and PCA. Such transformations may make the assumption of multivariate normality more appropriate. A sequential procedure using Mahalanobis distance and the Hotelling two-sample T2 test is illustrated using glass major element data from trachytic to phonolitic Kenyan tephras. All these methods require a broad range of high-quality compositional data which can be used to compare 'unknowns' with reference (training) sets that are sufficiently complete to account for all possible correlatives, including tephras with heterogeneous glasses that contain multiple compositional groups. Currently, incomplete databases are tending to limit correlation efficacy. The development of an open, online global database to facilitate progress towards integrated, high-quality tephrostratigraphic frameworks for different regions is encouraged.

  12. Strain-dependent activation energy of shear transformation in metallic glasses

    NASA Astrophysics Data System (ADS)

    Xu, Bin; Falk, Michael; Li, Jinfu; Kong, Lingti

    2017-04-01

    Shear transformation (ST) plays a decisive role in determining the mechanical behavior of metallic glasses, which is believed to be a stress-assisted thermally activated process. Understanding the dependence in its activation energy on the stress imposed on the material is of central importance to model the deformation process of metallic glasses and other amorphous solids. Here a theoretical model is proposed to predict the variation of the minimum energy path (MEP) associated with a particular ST event upon further deformation. Verification based on atomistic simulations and calculations are also conducted. The proposed model reproduces the MEP and activation energy of an ST event under different imposed macroscopic strains based on a known MEP at a reference strain. Moreover, an analytical approach is proposed based on the atomistic calculations, which works well when the stress varies linearity along the MEP. These findings provide necessary background for understanding the activation processes and, in turn, the mechanical behavior of metallic glasses.

  13. Evaluation of laser ablation double-focusing SC-ICPMS for “common” lead isotopic measurements in silicate glasses and mineral

    USGS Publications Warehouse

    Pietruszka, Aaron J.; Neymark, Leonid

    2017-01-01

    An analytical method for the in situ measurement of “common” Pb isotope ratios in silicate glasses and minerals using a 193-nm excimer laser ablation (LA) system with a double-focusing single-collector (SC)-ICPMS is presented and evaluated as a possible alternative to multiple-collector (MC)-ICPMS. This LA-SC-ICPMS technique employs fast-scanning ion deflectors to sequentially place a series of flat-topped isotope peaks into a single ion-counting detector at a fixed accelerating voltage and magnetic field strength. Reference materials (including NIST, MPI-DING, and USGS glasses) are used to identify two analytical artifacts on the Pb isotope ratios (expressed here as heavier/lighter isotopes) when corrected for mass bias relative to NIST SRM610. The first artifact is characterized by anomalously low Pb isotope ratios (~0.1%/AMU) when SRM610 is analyzed in raster mode as an unknown at small spot sizes (<25 µm), which may indicate that (1) SRM610 is isotopically heterogeneous on a small length scale and/or (2) there is a non-spectral matrix effect on the Pb isotope ratios related to differences in spot size. The second artifact is characterized by anomalously high Pb isotope ratios (<0.1%/AMU) for NIST SRM612 (in raster mode) and some Fe-rich glass reference materials (BCR-2G, GOR132-G, and T1-G). These offsets are thought to be caused by one or more non-spectral matrix effects related to differences in the ablation behavior, composition, or physical properties of these reference materials compared to the bracketing SRM610 standard. The precision (±2SD) of our LA-SC-ICPMS Pb isotopic measurements is similar to (207Pb/206Pb and 208Pb/206Pb, or 20XPb/206Pb) or better than (206Pb/204Pb,207Pb/204Pb, and 208Pb/204Pb, or 20XPb/204Pb) a series of published studies that used a different type of SC-ICPMS and obtained a factor of ~3-4 higher sensitivity for Pb. An increase in the sensitivity of our LA-SC-ICPMS would likely improve the precision of the 20XPb/206Pb and 20XPb/204Pb ratios for low-Pb materials (<5 ppm), possibly making the technique broadly similar to LA-MC-ICPMS (particularly compared to methods that rely upon at least one ion-counting detector). Further improvement in the precision of the 20XPb/206Pb and 20XPb/204Pb ratios for high-Pb materials (>5 ppm) by LA-SC-ICPMS is unlikely, and in this case, LA-MC-ICPMS remains the preferable analytical technique.

  14. Dissolving Bubbles in Glass

    NASA Technical Reports Server (NTRS)

    Weinberg, M. C.; Oronato, P. I.; Uhlmann, D. R.

    1984-01-01

    Analytical expression used to calculate time it takes for stationary bubbles of oxygen and carbon dioxide to dissolve from glass melt. Technique based on analytical expression for bubble radius as function time, with consequences of surface tension included.

  15. A Comparison of the Glass Meta-Analytic Technique with the Hunter-Schmidt Meta-Analytic Technique on Three Studies from the Education Literature.

    ERIC Educational Resources Information Center

    Hough, Susan L.; Hall, Bruce W.

    The meta-analytic techniques of G. V. Glass (1976) and J. E. Hunter and F. L. Schmidt (1977) were compared through their application to three meta-analytic studies from education literature. The following hypotheses were explored: (1) the overall mean effect size would be larger in a Hunter-Schmidt meta-analysis (HSMA) than in a Glass…

  16. Strontium isotope measurement of basaltic glasses by laser ablation multiple collector inductively coupled plasma mass spectrometry based on a linear relationship between analytical bias and Rb/Sr ratios.

    PubMed

    Zhang, Le; Ren, Zhong-Yuan; Wu, Ya-Dong; Li, Nan

    2018-01-30

    In situ strontium (Sr) isotope analysis of geological samples by laser ablation multiple collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) provides useful information about magma mixing, crustal contamination and crystal residence time. Without chemical separation, during Sr isotope analysis with laser ablation, many kinds of interference ions (such as Rb + and Kr + ) are on the Sr isotope spectrum. Most previous in situ Sr isotope studies only focused on Sr-enriched minerals (e.g. plagioclase, calcite). Here we established a simple method for in situ Sr isotope analysis of basaltic glass with Rb/Sr ratio less than 0.14 by LA-MC-ICP-MS. Seven Faraday cups, on a Neptune Plus MC-ICP-MS instrument, were used to receive the signals on m/z 82, 83, 84, 85, 86, 87 and 88 simultaneously for the Sr isotope analysis of basaltic glass. The isobaric interference of 87 Rb was corrected by the peak stripping method. The instrumental mass fractionation of 87 Sr/ 86 Sr was corrected to 86 Sr/ 88 Sr = 0.1194 with an exponential law. Finally, the residual analytical biases of 87 Sr/ 86 Sr were corrected with a relationship between the deviation of 87 Sr/ 86 Sr from the reference values and the measured 87 Rb/ 86 Sr. The validity of the protocol present here was demonstrated by measuring the Sr isotopes of four basaltic glasses, a plagioclase crystal and a piece of modern coral. The measured 87 Sr/ 86 Sr ratios of all these samples agree within 100 ppm with the reference values. In addition, the Sr isotopes of olivine-hosted melt inclusions from the Emeishan large igneous province (LIP) were measured to show the application of our method to real geological samples. A simple but accurate approach for in situ Sr isotope measurement by LA-MC-ICP-MS has been established, which should greatly facilitate the wider application of in situ Sr isotope geochemistry, especially to volcanic rock studies. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Reference-based optical characterization of glass-ceramic converter for high-power white LEDs

    NASA Astrophysics Data System (ADS)

    Engel, A.; Letz, M.; Zachau, T.; Pawlowski, E.; Seneschal-Merz, K.; Korb, T.; Enseling, D.; Hoppe, B.; Peuchert, U.; Hayden, J. S.

    2007-02-01

    Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools and detection methods for product and process control, material sciences, environmental and bio-technical analysis, molecular genetics, cell biology, medical diagnostics and drug screening. According to DIN/ISO 17025 certified standards are used for fluorescence diagnostics having the drawback of giving relative values for fluorescence intensities only. Therefore reference materials for a quantitative characterization have to be related directly to the materials under investigation. In order to evaluate these figures it is necessary to calculate absolute numbers like absorption/excitation cross section and quantum yield. This can be done for different types of dopants in different materials like glass, glass ceramics, crystals or nano crystalline material embedded in polymer matrices. Here we consider a special type of glass ceramic with Ce doped YAG as the main crystalline phase. This material has been developed for the generation of white light realized by a blue 460 nm semiconductor transition using a yellow phosphor or converter material respectively. Our glass ceramic is a pure solid state solution for a yellow phosphor. For the production of such a kind of material a well controlled thermal treatment is employed to transfer the original glass into a glass ceramic with a specific crystalline phase. In our material Ce doped YAG crystallites of a size of several µm are embedded in a matrix of a residual glass. We present chemical, structural and spectroscopic properties of our material. Based on this we will discuss design options for white LED's with respect to heat management, scattering regime, reflection losses, chemical durability and stability against blue and UV radiation, which evolve from our recently developed material. In this paper we present first results on our approaches to evaluate quantum yield and light output. Used diagnostics are fluorescence (steady state, decay time) and absorption (remission, absorption) spectroscopy working in different temperature regimes (10 - 350 K) of the measured samples in order to get a microscopic view of the relevant physical processes and to prove the correctness of the obtained data.

  18. Characterization of a Polymer Composite Section of Foreign Armor

    DTIC Science & Technology

    2000-03-01

    Core Sample 8 6. ESEM From Owens - Corning S-2 Glass Reference 10 7. ESEM From Owens-Coming E Glass Reference 11 8. ESEM From Known Russian S...light element energy dispersive spectrometer. Samples of domestic Owens - Corning E and S-2 glass fibers were first analyzed for reference purposes...for comparison to the unknown Russian armor fiber. The two domestic reference fibers were Owens - Corning E and S-2 glass. Their spectra are shown in

  19. Verification of an Analytical Method for Measuring Crystal Nucleation Rates in Glasses from DTA Data

    NASA Technical Reports Server (NTRS)

    Ranasinghe, K. S.; Wei, P. F.; Kelton, K. F.; Ray, C. S.; Day, D. E.

    2004-01-01

    A recently proposed analytical (DTA) method for estimating the nucleation rates in glasses has been evaluated by comparing experimental data with numerically computed nucleation rates for a model lithium disilicate glass. The time and temperature dependent nucleation rates were predicted using the model and compared with those values from an analysis of numerically calculated DTA curves. The validity of the numerical approach was demonstrated earlier by a comparison with experimental data. The excellent agreement between the nucleation rates from the model calculations and fiom the computer generated DTA data demonstrates the validity of the proposed analytical DTA method.

  20. Theoretical study of production of unique glasses in space

    NASA Technical Reports Server (NTRS)

    Larsen, D. C.

    1974-01-01

    Analytical functional relationships describing homogeneous nucleation and crystallization in various supercooled liquids were developed. The time and temperature dependent relationships of nucleation and crystallization (intrinsic properties) are being used to relate glass forming tendency to extrinsic parameters such as cooling rate through computer simulation. Single oxide systems are being studied initially to aid in developing workable kinetic models and to indicate the primary materials parameters affecting glass formation. The theory and analytical expressions developed for simple systems is then extended to complex oxide systems. A thorough understanding of nucleation and crystallization kinetics of glass forming systems provides a priori knowledge of the ability of a given system to form a glass.

  1. Geochemical features of glass beads excavated from the Iron Age archaeological sites, Eastern Taiwan

    NASA Astrophysics Data System (ADS)

    Yang, H.

    2016-12-01

    The uses of metallic artifacts began 2500-2000 years ago in Taiwan; in the meanwhile glass beads have also been as a common ornament by the prehistoric people. Glass, as the earliest artificial ornament, is made by a mixture of quartz sands and flux which were heated to more than one thousand Celsius degrees. Therefore, the production processes, raw material provenance and exchange systems could be revealed by the chemical compositions of glass artifacts. The chemical composition of glass beads studies from four archaeological sites (PL, PN, CHL and TL sites) in early Iron Age are reported in this study. By the producing in drawn method and limited ranges of colors with various hue, all the studied glass beads here should be classified as Indo-Pacific glass beads. As these ancient glass beads are unique and precious, a non-destructive analytical method is always considered at the initial stage. Therefore, we use the best known and most widely-used of the surface analytical techniques SEM/EDX to get the surface and quantitative elemental information of glass beads. According to the analytical results, the PL and PN glass beads all belong to potassium silica glass and those coexisting with so-called Kueishan sherds excavated from CHL and TL sites should be classified as sodium-calcium glass which is the most general composition of Indo-Pacific glass beads. Not only the different flux using between potassium and sodium glass, the variation in the aluminum contents between potassium and sodium glass also exhibits different provenances of glass-making raw materials. As lack of glass-making remains in Taiwan, these ancient glass beads were considered as a precious and trading artifact to Taiwan from overseas and introduced into prehistoric societies via various sources and paths. Although the trading/exchange routes of ancient glass beads are still debatable, we find that compositional analyses can help answer such questions as what types of glass were used for their manufacture and with separate traditions and hope the results can give us some insight into the potential beadmaking sites and in addition to establish the exchange networks of prehistoric people.

  2. Proposed method for determining the thickness of glass in solar collector panels

    NASA Technical Reports Server (NTRS)

    Moore, D. M.

    1980-01-01

    An analytical method was developed for determining the minimum thickness for simply supported, rectangular glass plates subjected to uniform normal pressure environmental loads such as wind, earthquake, snow, and deadweight. The method consists of comparing an analytical prediction of the stress in the glass panel to a glass breakage stress determined from fracture mechanics considerations. Based on extensive analysis using the nonlinear finite element structural analysis program ARGUS, design curves for the structural analysis of simply supported rectangular plates were developed. These curves yield the center deflection, center stress and corner stress as a function of a dimensionless parameter describing the load intensity. A method of estimating the glass breakage stress as a function of a specified failure rate, degree of glass temper, design life, load duration time, and panel size is also presented.

  3. Use of sol-gels as solid matrixes for simultaneous multielement determination by radio frequency glow discharge optical emission spectrometry: determinations of suspended particulate matter.

    PubMed

    Davis, W Clay; Knippel, Brad C; Cooper, Julia E; Spraul, Bryan K; Rice, Jeanette K; Smith, Dennis W; Marcus, R Kenneth

    2003-05-15

    A new approach for the analysis of particulate matter by radio frequency glow discharge optical emission spectrometry (rf-GD-OES) is described. Dispersion of the particles in a sol-gel sample matrix provides a convenient means of generating a thin film suitable for sputter-sampling into the discharge. Acid-catalyzed sol-gel glasses synthesized from tetramethyl orthosilicate were prepared and spun-cast on glass substrates. The resultant thin films on glass substrates were analyzed to determine the discharge operating conditions and resultant sputtering characteristics while a number of optical emission lines of the film components were monitored. Slurries of powdered standard reference materials NIST SRM 1884a (Portland Cement) and NIST SRM 2690 (Coal Fly Ash) dispersed in the sols were cast into films in the same manner. Use of the sol-gels as sample matrixes allows for background subtraction through the use of analytical blanks and may facilitate the generation of calibration curves via readily synthesized, matrix-matched analytical standards in solids analysis. Detection limits were determined for minor elements via the RSDB method to be in the range of 1-10 microg/g in Portland Cement and Coal Fly Ash samples for the elements Al, Fe, Mg, S, and Si. Values for Ca were in the range of 15-35 microg/g. This preliminary study demonstrates the possibility of incorporating various insoluble species, including ceramics and geological specimens in powder form, into a solid matrix for further analysis by either rf-GD-OES or MS.

  4. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  5. Inverted glass harp

    NASA Astrophysics Data System (ADS)

    Quinn, Daniel B.; Rosenberg, Brian J.

    2015-08-01

    We present an analytical treatment of the acoustics of liquid-filled wine glasses, or "glass harps." The solution is generalized such that under certain assumptions it reduces to previous glass harp models, but also leads to a proposed musical instrument, the "inverted glass harp," in which an empty glass is submerged in a liquid-filled basin. The versatility of the solution demonstrates that all glass harps are governed by a family of solutions to Laplace's equation around a vibrating disk. Tonal analyses of recordings for a sample glass are offered as confirmation of the scaling predictions.

  6. Chemical durability of alkali-borosilicate glasses studied by analytical SEM, IBA, isotopic-tracing and SIMS

    NASA Astrophysics Data System (ADS)

    Trocellier, P.; Djanarthany, S.; Chêne, J.; Haddi, A.; Brass, A. M.; Poissonnet, S.; Farges, F.

    2005-10-01

    Simple and complex alkali-borosilicate glasses were submitted to aqueous corrosion at room temperature, 60 and 90 °C in solutions with pH ranging between 0 and 12. Analytical scanning electron microscopy (SEM), ion beam analysis (IBA) techniques, isotopic tracing and secondary ion mass-depth profiling (SIMS) have been used to investigate the variations of the surface composition of glass. In acidic medium, the glass surface is generally covered by a thick hydrated silica layer, mobile elements like Li, Na and B and transition elements (Fe, Zr, Mo, etc.) are strongly depleted. Near pH 7, relative enrichments of aluminium, iron and rare earths are shown together with strong Li, Na and B depletions. In basic medium, the glass surface exhibits relative enrichments of the major part of transition metals (from Cr to U) whereas mobile elements seem to be kept close to their nominal concentration level at the glass surface and Si is severely impoverished. Hydrogen incorporated at the glass surface after leaching is much more immobile in neutral and basic media than in acid medium.

  7. Third order nonlinear optical properties of a paratellurite single crystal

    NASA Astrophysics Data System (ADS)

    Duclère, J.-R.; Hayakawa, T.; Roginskii, E. M.; Smirnov, M. B.; Mirgorodsky, A.; Couderc, V.; Masson, O.; Colas, M.; Noguera, O.; Rodriguez, V.; Thomas, P.

    2018-05-01

    The (a,b) plane angular dependence of the third-order nonlinear optical susceptibility, χ(3) , of a c-cut paratellurite (α-TeO2) single crystal was quantitatively evaluated here by the Z-scan technique, using a Ti:sapphire femtosecond laser operated at 800 nm. In particular, the mean value Re( ⟨χ(3)⟩a,b )(α-TeO2) of the optical tensor has been extracted from such experiments via a direct comparison with the data collected for a fused silica reference glass plate. A R e (⟨χ(3)⟩(a,b )(α-TeO2)):R e (χ(3))(SiO2 glass) ratio roughly equal to 49.1 is found, and our result compares thus very favourably with the unique experimental value (a ratio of ˜50) reported by Kim et al. [J. Am. Ceram. Soc. 76, 2486 (1993)] for a pure TeO2 glass. In addition, it is shown that the angular dependence of the phase modulation within the (a,b) plane can be fully understood in the light of the strong dextro-rotatory power known for TeO2 materials. Taking into account the optical activity, some analytical model serving to estimate the diagonal and non-diagonal components of the third order nonlinear susceptibility tensor has been thus developed. Finally, Re( χxxxx(3) ) and Re( χxxyy(3) ) values of 95.1 ×10-22 m 2/V2 and 42.0 ×10-22 m2/V2 , respectively, are then deduced for a paratellurite single crystal, considering fused silica as a reference.

  8. New Material for Surface-Enhanced Raman Spectroscopy

    NASA Technical Reports Server (NTRS)

    Farquharson, Stuart; Nelson, Chad; Lee, Yuan

    2004-01-01

    A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

  9. Effects of Aging-Time Reference on the Long Term Behavior of the IM7/K3B Composite

    NASA Technical Reports Server (NTRS)

    Veazie, David R.; Gates, Thomas S.

    1998-01-01

    An analytical study was undertaken to investigate the effects of the time-based shift reference on the long term behavior of the graphite reinforced thermoplastic polyimide composite IM7/K3B at elevated temperature. Creep compliance and the effects of physical aging on the time dependent response was measured for uniaxial loading at several isothermal conditions below the glass transition temperature (T(sub g). Two matrix dominated loading modes, shear and transverse, were investigated in tension and compression. The momentary sequenced creep/aging curves were collapsed through a horizontal (time) shift using the shortest, middle and longest aging time curve as the reference curve. Linear viscoelasticity was used to characterize the creep/recovery behavior and superposition techniques were used to establish the physical aging related material constants. The use of effective time expressions in a laminated plate model allowed for the prediction of long term creep compliance. The effect of using different reference curves with time/aging-time superposition was most sensitive to the physical aging shift rate at lower test temperatures. Depending on the loading mode, the reference curve used can result in a more accurate long term prediction, especially at lower test temperatures.

  10. Preparation of wafer-level glass cavities by a low-cost chemical foaming process (CFP).

    PubMed

    Shang, Jintang; Chen, Boyin; Lin, Wei; Wong, Ching-Ping; Zhang, Di; Xu, Chao; Liu, Junwen; Huang, Qing-An

    2011-04-21

    A novel foaming process-chemical foaming process (CFP)-using foaming agents to fabricate wafer-level micro glass cavities including channels and bubbles was investigated. The process consists of the following steps sequentially: (1) shallow cavities were fabricated by a wet etching on a silicon wafer; (2) powders of a proper foaming agent were placed in a silicon cavity, named 'mother cavity', on the etched silicon surface; (3) the silicon cavities were sealed with a glass wafer by anodic bonding; (4) the bonded wafers were heated to above the softening point of the glass, and baked for several minutes, when the gas released by the decomposition of the foaming agent in the 'mother cavity' went into the other sealed interconnected silicon cavities to foam the softened glass into cylindrical channels named 'daughter channels', or spherical bubbles named 'son bubbles'. Results showed that wafer-level micro glass cavities with smooth wall surfaces were achieved successfully without contamination by the CFP. A model for the CFP was proposed to predict the final shape of the glass cavity. Experimental results corresponded with model predictions. The CFP provides a low-cost avenue to preparation of micro glass cavities of high quality for applications such as micro-reactors, micro total analysis systems (μTAS), analytical and bio-analytical applications, and MEMS packaging.

  11. IMPROVED METHOD FOR THE STORAGE OF GROUND WATER SAMPLES CONTAINING VOLATILE ORGANIC ANALYTES

    EPA Science Inventory

    The sorption of volatile organic analytes from water samples by the Teflon septum surface used with standard glass 40-ml sample collection vials was investigated. Analytes tested included alkanes, isoalkanes, olefins, cycloalkanes, a cycloalkene, monoaromatics, a polynuclear arom...

  12. Ag2O:SiO2:V2O5 Glass System:. a Novel Reference Electrode for SO2 Gas Sensor

    NASA Astrophysics Data System (ADS)

    Singh, K.; Lad, A.; Bhoga, S. S.

    2002-12-01

    Ag2O:SiO2:V2O5 glass system with 0.5≤ y ≥ 0.66 for fixed n = 9 is synthesized, structurally and electrically characterized with a view to have high glass transition temperature (Tg ≈ 500°C) which can be used as solid reference electrode in electrochemical SOx gas sensor application. 10Ag2O:40SiO2:50V2O5 glass having Tg ≈ 502°C exhibits maximum bulk and electronic conductivity 3.67*10-3 and 4.47*10-2 S/cm, respectively at 450°C. The increase in conductivity is understood to be due to a mixed former effect. A few galvanic SOx sensors fabricated utilizing optimized glass as reference and Ag+ conducting solid electrolyte responds to change in PSOx according to 2 electron cell reaction.

  13. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    PubMed

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  14. Some Properties of Glass and Carbonate in the D'Orbigny Angrite

    NASA Astrophysics Data System (ADS)

    Kubny, A.; Banerjee, A.; Jagoutz, E.; Varela, M. E.; Brandstätter, F.; Kurat, G.

    2003-04-01

    Introduction: The angrite D'Orbigny is unusually rich in glass as compared to other members of the angrite group [1, 2]. The most common glass fills open spaces in druses and hollow shells. Carbonate fills in part the abundant open spaces. Inside hollow shells, in the center of the rocks, it forms crystal bushels and is white. In contrast, near the surface of the meteorite, it forms crusts and has an ochre color. Analytical Methods and Results: Glass in some of the abundant open spaces in D'Orbigny, druses and hollow shells, is black (brown in thin section) [1, 2]. Its chemical composition is similar to that of the bulk rock for major, minor and trace elements [1-3]. The glass easily dissolves in part in aqua regia producing a clear yellow solution and a white, porous residue. The white and porous leach residue preserved the shape of the original glass sample and consists mainly of SiO_2 (93 wt%) with low contents of TiO_2 (˜1 wt%), Al_2O_3 (3-4 wt%) and FeO (0.5-1.5 wt%), as determined by electron microprobe analysis. The determination of the ion concentrations of the solution also shows that all major elements, except Si and Ti were dissolved. In contrast to the reaction of D'Orbigny glass with aqua regia giving a residue, treating with 25% aqueous HCl produces a yellow solution which forms a yellow gel within some days. The Raman spectrum of the D'Orbigny glass shows the typical spectral features of an aluminosilicate glass, whereas that of its white leach residue shows bands which can be attributed to amorphous silica structured of four-membered siloxane rings of SiO_4 tetrahedra. The structure of the carbonate could be determined by Raman spectroscopy. The white bushels show the spectral features of pure calcite whereas the ochre crust exhibits Raman bands of disturbed calcite which are almost completely hidden by the highly fluorescent background. References: [1] Kurat G. et al. (2001) LPS XXXII, 1737.pdf; [2] Varela M. E. et al. (2001) LPS XXXII, 1803.pdf; [3] Varela M. E. et al. (2001) MAPS 36, A201.

  15. Major to ultra trace element bulk rock analysis of nanoparticulate pressed powder pellets by LA-ICP-MS

    NASA Astrophysics Data System (ADS)

    Peters, Daniel; Pettke, Thomas

    2016-04-01

    An efficient, clean procedure for bulk rock major to trace element analysis by 193 nm Excimer LA-ICP-MS analysis of nanoparticulate pressed powder pellets (PPPs) employing a binder is presented. Sample powders are milled in water suspension in a planetary ball mill, reducing average grain size by about one order of magnitude compared to common dry milling protocols. Microcrystalline cellulose (MCC) is employed as a binder, improving the mechanical strength of the PPP and the ablation behaviour, because MCC absorbs 193 nm laser light well. Use of MCC binder allows for producing cohesive pellets of materials that cannot be pelletized in their pure forms, such as quartz powder. Rigorous blank quantification was performed on synthetic quartz treated like rock samples, demonstrating that procedural blanks are irrelevant except for a few elements at the 10 ng g-1 concentration level. The LA-ICP-MS PPP analytical procedure was optimised and evaluated using six different SRM powders (JP-1, UB-N, BCR-2, GSP-2, OKUM, and MUH-1). Calibration based on external standardization using SRM 610, SRM 612, BCR-2G, and GSD-1G glasses allows for evaluation of possible matrix effects during LA-ICP-MS analysis. The data accuracy of the PPP LA-ICP-MS analytical procedure compares well to that achieved for liquid ICP-MS and LA-ICP-MS glass analysis, except for element concentrations below ˜30 ng g-1, where liquid ICP-MS offers more precise data and in part lower limits of detection. Uncertainties on the external reproducibility of LA-ICP-MS PPP element concentrations are of the order of 0.5 to 2 % (1σ standard deviation) for concentrations exceeding ˜1 μg g-1. For lower element concentrations these uncertainties increase to 5-10% or higher when analyte-depending limits of detection (LOD) are approached, and LODs do not significantly differ from glass analysis. Sample homogeneity is demonstrated by the high analytical precision, except for very few elements where grain size effects can rarely still be resolved analytically. Matrix effects are demonstrated for PPP analysis of diverse rock compositions and basalt glass analysis when externally calibrated based on SRM 610 and SRM 612 glasses; employing basalt glass GSD-1G or BCR-2G for external standardisation basically eliminates these problems. Perhaps the most prominent progress of the LA-ICP-MS PPP analytical procedure presented here is the fact that trace elements not commonly analysed, i.e. new, unconventional geochemical tracers, can be measured straightforwardly, including volatile elements, the flux elements Li and B, the chalcophile elements As, Sb, Tl, Bi, and elements that alloy with metal containers employed in conventional glass production approaches. The method presented here thus overcomes many common problems and limitations in analytical geochemistry and is shown to be an efficient alternative for bulk rock trace elements analysis.

  16. ILAW Glass Testing for Disposal at IDF: Phase 1 Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papathanassiu, Adonia; Muller, Isabelle S.; Brandys, Marek

    2011-04-11

    This document reports the results of the testing of phase 1 ORP LAW (low activity waste) glasses, also identified as enhanced LAW glasses. Testing involved are SPFT (Single Pass Flow Through), VHT (Vapor Hydration Test), and PCT (Product Consistency Test), along with the analytical tests (XRD and SEM-EDS). This report contains the data of the high waste loading ORP LAW glasses that will be used for the performance assessment of the IDF (Integrated Disposal Facility).

  17. Rayleigh approximation to ground state of the Bose and Coulomb glasses

    PubMed Central

    Ryan, S. D.; Mityushev, V.; Vinokur, V. M.; Berlyand, L.

    2015-01-01

    Glasses are rigid systems in which competing interactions prevent simultaneous minimization of local energies. This leads to frustration and highly degenerate ground states the nature and properties of which are still far from being thoroughly understood. We report an analytical approach based on the method of functional equations that allows us to construct the Rayleigh approximation to the ground state of a two-dimensional (2D) random Coulomb system with logarithmic interactions. We realize a model for 2D Coulomb glass as a cylindrical type II superconductor containing randomly located columnar defects (CD) which trap superconducting vortices induced by applied magnetic field. Our findings break ground for analytical studies of glassy systems, marking an important step towards understanding their properties. PMID:25592417

  18. Mackey-Glass equation driven by fractional Brownian motion

    NASA Astrophysics Data System (ADS)

    Nguyen, Dung Tien

    2012-11-01

    In this paper we introduce a fractional stochastic version of the Mackey-Glass model which is a potential candidate to model objects in biology and finance. By a semi-martingale approximate approach we find an semi-analytical expression for the solution.

  19. Degradation of glass artifacts: application of modern surface analytical techniques.

    PubMed

    Melcher, Michael; Wiesinger, Rita; Schreiner, Manfred

    2010-06-15

    A detailed understanding of the stability of glasses toward liquid or atmospheric attack is of considerable importance for preserving numerous objects of our cultural heritage. Glasses produced in the ancient periods (Egyptian, Greek, or Roman glasses), as well as modern glass, can be classified as soda-lime-silica glasses. In contrast, potash was used as a flux in medieval Northern Europe for the production of window panes for churches and cathedrals. The particular chemical composition of these potash-lime-silica glasses (low in silica and rich in alkali and alkaline earth components), in combination with increased levels of acidifying gases (such as SO(2), CO(2), NO(x), or O(3)) and airborne particulate matter in today's urban or industrial atmospheres, has resulted in severe degradation of important cultural relics, particularly over the last century. Rapid developments in the fields of microelectronics and computer sciences, however, have contributed to the development of a variety of nondestructive, surface analytical techniques for the scientific investigation and material characterization of these unique and valuable objects. These methods include scanning electron microscopy in combination with energy- or wavelength-dispersive spectrometry (SEM/EDX or SEM/WDX), secondary ion mass spectrometry (SIMS), and atomic force microscopy (AFM). In this Account, we address glass analysis and weathering mechanisms, exploring the possibilities (and limitations) of modern analytical techniques. Corrosion by liquid substances is well investigated in the glass literature. In a tremendous number of case studies, the basic reaction between aqueous solutions and the glass surfaces was identified as an ion-exchange reaction between hydrogen-bearing species of the attacking liquid and the alkali and alkaline earth ions in the glass, causing a depletion of the latter in the outermost surface layers. Although mechanistic analogies to liquid corrosion are obvious, atmospheric attack on glass ("weathering") is much more complex due to the multiphase system (atmosphere, water film, glass surface, and bulk glass) and added complexities (such as relative humidity and atmospheric pollutant concentration). Weathered medieval stained glass objects, as well as artifacts under controlled museum conditions, typically have less transparent or translucent surfaces, often with a thick weathering crust on top, consisting of sulfates of the glass constituents K, Ca, Na, or Mg. In this Account, we try to answer questions about glass analysis and weathering in three main categories. (i) Which chemical reactions are involved in the weathering of glass surfaces? (ii) Which internal factors (such as the glass composition or surface properties) play a dominant role for the weathering process? Can certain environmental or climatic factors be identified as more harmful for glasses than others? Is it possible to set up a quantitative relationship or at least an approximation between the degree of weathering and the factors described above? (iii) What are the consequences for the restoration and conservation strategies of endangered glass objects? How can a severe threat to precious glass objects be avoided, or at least minimized, to preserve these artifacts of our cultural heritage for future generations?

  20. Electrolytic cell with reference electrode

    DOEpatents

    Kessie, Robert W.

    1989-01-01

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane.

  1. Reference electrode for electrolytic cell

    DOEpatents

    Kessie, R.W.

    1988-07-28

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane. 4 figs.

  2. Polyglycerol based coatings to reduce non-specific protein adsorption in sample vials and on SPR sensors.

    PubMed

    Becherer, Tobias; Grunewald, Christian; Engelschalt, Vivienne; Multhaup, Gerhard; Risse, Thomas; Haag, Rainer

    2015-03-31

    Coatings based on dendritic polyglycerol (dPG) were investigated for their use to control nonspecific protein adsorption in an assay targeted to analyze concentrations of a specific protein. We demonstrate that coating of the sample vial with dPG can significantly increase the recovery of an antibody after incubation. First, we determine the concentration dependent loss of an antibody due to nonspecific adsorption to glass via quartz crystal microbalance (QCM). Complementary to the QCM measurements, we applied the same antibody as analyte in an surface plasmon resonance (SPR) assay to determine the loss of analyte due to nonspecific adsorption to the sample vial. For this purpose, we used two different coatings based on dPG. For the first coating, which served as a matrix for the SPR sensor, carboxyl groups were incorporated into dPG as well as a dithiolane moiety enabling covalent immobilization to the gold sensor surface. This SPR-matrix exhibited excellent protein resistant properties and allowed the immobilization of amyloid peptides via amide bond formation. The second coating which was intended to prevent nonspecific adsorption to glass vials comprised a silyl moiety that allowed covalent grafting to glass. For demonstrating the impact of the vial coating on the accuracy of an SPR assay, we immobilized amyloid beta (Aβ) 1-40 and used an anti-Aβ 1-40 antibody as analyte. Alternate injection of analyte into the flow cell of the SPR device from uncoated and coated vials, respectively gave us the relative signal loss (1-RUuncoated/RUcoated) caused by the nonspecific adsorption. We found that the relative signal loss increases with decreasing analyte concentration. The SPR data correlate well with concentration dependent non-specific adsorption experiments of the analyte to glass surfaces performed with QCM. Our measurements show that rendering both the sample vial and the sensor surface is crucial for accurate results in protein assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Analyses of kinetic glass transition in short-range attractive colloids based on time-convolutionless mode-coupling theory.

    PubMed

    Narumi, Takayuki; Tokuyama, Michio

    2017-03-01

    For short-range attractive colloids, the phase diagram of the kinetic glass transition is studied by time-convolutionless mode-coupling theory (TMCT). Using numerical calculations, TMCT is shown to recover all the remarkable features predicted by the mode-coupling theory for attractive colloids: the glass-liquid-glass reentrant, the glass-glass transition, and the higher-order singularities. It is also demonstrated through the comparisons with the results of molecular dynamics for the binary attractive colloids that TMCT improves the critical values of the volume fraction. In addition, a schematic model of three control parameters is investigated analytically. It is thus confirmed that TMCT can describe the glass-glass transition and higher-order singularities even in such a schematic model.

  4. Rayleigh approximation to ground state of the Bose and Coulomb glasses

    DOE PAGES

    Ryan, S. D.; Mityushev, V.; Vinokur, V. M.; ...

    2015-01-16

    Glasses are rigid systems in which competing interactions prevent simultaneous minimization of local energies. This leads to frustration and highly degenerate ground states the nature and properties of which are still far from being thoroughly understood. We report an analytical approach based on the method of functional equations that allows us to construct the Rayleigh approximation to the ground state of a two-dimensional (2D) random Coulomb system with logarithmic interactions. We realize a model for 2D Coulomb glass as a cylindrical type II superconductor containing randomly located columnar defects (CD) which trap superconducting vortices induced by applied magnetic field. Ourmore » findings break ground for analytical studies of glassy systems, marking an important step towards understanding their properties.« less

  5. An integrated analytical approach for characterizing an organic residue from an archaeological glass bottle recovered in Pompeii (Naples, Italy).

    PubMed

    Ribechini, Erika; Modugno, Francesca; Baraldi, Cecilia; Baraldi, Pietro; Colombini, Maria Perla

    2008-01-15

    Within the framework of an Italian research project aimed at studying organic residues found in archaeological objects from the Roman period, the chemical composition of the contents of several glass vessels recovered from archaeological sites from the Vesuvian area (Naples, Italy) was investigated. In particular, this paper deals with the study of an organic material found in a glass bottle from the archaeological site of Pompeii using a multi-analytical approach, including FT-IR, direct exposure mass spectrometry (DE-MS) and GC-MS techniques. The overall results suggest the occurrence of a lipid material of vegetable origin. The hypothesis that the native lipid material had been subjected to a chemical transformation procedure before being used is presented and discussed.

  6. Slump with Success

    ERIC Educational Resources Information Center

    White, Heather

    2008-01-01

    Glass slumping is one of those projects that gives students a feeling of success and accomplishment. Glass slumping looks difficult to produce, and it often leaves others wondering how it is created. Slumping glass can provide dramatic results. Slumping refers to glass that, when heated, softens and conforms to the shape of a mold. Elementary…

  7. Designing Glass Panels for Economy and Reliability

    NASA Technical Reports Server (NTRS)

    Moore, D. M.

    1983-01-01

    Analytical method determines probability of failure of rectangular glass plates subjected to uniformly distributed loads such as those from wind, earthquake, snow, and deadweight. Developed as aid in design of protective glass covers for solar-cell arrays and solar collectors, method is also useful in estimating the reliability of large windows in buildings exposed to high winds and is adapted to nonlinear stress analysis of simply supported plates of any elastic material.

  8. Analytical characterization of glass tesserae from mosaics of early Christian basilicas in Albania

    NASA Astrophysics Data System (ADS)

    Vataj, Esmeralda; Hobdari, Elio; Röhrs, Stefan; Vandenabele, Peter; Civici, Nikolla

    2017-01-01

    The present paper constitutes the first archaeometric study of the glass mosaic tesserae recovered from the archaeological excavation of the mosaics at the Early Christian basilicas in Bylis, Lin and Elbasan, belonging to fifth to sixth century AD. The main objective of the study is the characterization of the materials, glass matrix, colourants and opacifiers used for their production. A multi-analytical approach, which includes optical microscopy, scanning electron microscopy equipped with energy-dispersive spectrometer, micro-X-ray fluorescence and Raman spectroscopy, is used during the investigation of 72 tesserae of different colours collected from the three sites. All the tesserae are opaque and have heterogeneous surfaces with several bubbles and crystalline inclusions. Most of the glass tesserae have the characteristic soda-lime-silica composition, and low concentrations of potash and magnesium indicate natron as soda source, which is typical for the Roman glass. Compounds containing Mn, Fe, Cu, Co, Pb and Sn are used as colourants in the tesserae of different colours. Mineral inclusions are mostly composed of undissolved raw materials, i.e., silicon-, calcium- and tin-rich particles. It is interesting to notice that SnO2 has been used as opacifier in all the tesserae. Thin layers of Au foil placed between two transparent glasses are identified in the gold-coloured tesserae.

  9. Membrane reference electrode

    DOEpatents

    Redey, L.; Bloom, I.D.

    1988-01-21

    A reference electrode utilizes a small thin, flat membrane of a highly conductive glass placed on a small diameter insulator tube having a reference material inside in contact with an internal voltage lead. When the sensor is placed in a non-aqueous ionic electrolytic solution, the concentration difference across the glass membrane generates a low voltage signal in precise relationship to the concentration of the species to be measured, with high spatial resolution. 2 figs.

  10. [Investigation of infiltration glass of the machinable infiltrated ceramic(MIC)].

    PubMed

    Liao, Y; Yang, H; Xan, S; Xue, Y; Chai, F

    2000-03-01

    To explore the manufacture arts and determine the properties of the infiltration glass of the MIC. In order to determine the glass forming range of the MIC infiltration glass, molten glass was prepared in Al2O3 crucibles by heating the components to 1450 degrees C. Thermal analytic device was employed to study the thermal properties of the glass. Its crystal phases after micro-crystallization were analyzed with XRD. Flexural strength was measured by means of 3-point bending test. The chemical components of MIC glass were determined. Conventional fluorophlogopite glass was converted into an infiltration glass with low viscosity, good infiltration capability and low fusing temperature by introducing B2O3, La2O3 and Li2O into the glass. Fluorophlogopite crystals formed after crystallization. Conventional mica glass can be changed according to the requirements of properties. Modified mica MIC glass in this study has good infiltration ability in Al2O3 matrix while remains machinability.

  11. Surface tension driven flow in glass melts and model fluids

    NASA Technical Reports Server (NTRS)

    Mcneil, T. J.; Cole, R.; Subramanian, R. S.

    1982-01-01

    Surface tension driven flow has been investigated analytically and experimentally using an apparatus where a free column of molten glass or model fluids was supported at its top and bottom faces by solid surfaces. The glass used in the experiments was sodium diborate, and the model fluids were silicone oils. In both the model fluid and glass melt experiments, conclusive evidence was obtained to prove that the observed flow was driven primarily by surface tension forces. The experimental observations are in qualitative agreement with predictions from the theoretical model.

  12. Microbeam Characterization of Corning Archeological Reference Glasses: New Additions to the Smithsonian Microbeam Standard Collection

    PubMed Central

    Vicenzi, Edward P.; Eggins, Stephen; Logan, Amelia; Wysoczanski, Richard

    2002-01-01

    An initial study of the minor element, trace element, and impurities in Corning archeological references glasses have been performed using three microbeam techniques: electron probe microanalysis (EPMA), laser ablation ICP-mass spectrometry (LA ICP-MS), and secondary ion mass spectrometry (SIMS). The EPMA results suggest a significant level of heterogeneity for a number of metals. Conversely, higher precision and a larger sampling volume analysis by LA ICP-MS indicates a high degree of chemical uniformity within all glasses, typically <2 % relative (1 σ). SIMS data reveal that small but measurable quantities of volatile impurities are present in the glasses, including H at roughly the 0.0001 mass fraction level. These glasses show promise for use as secondary standards for minor and trace element analyses of insulating materials such as synthetic ceramics, minerals, and silicate glasses. PMID:27446764

  13. Sol-Gel Matrices For Direct Colorimetric Detection Of Analytes

    DOEpatents

    Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey

    2002-11-26

    The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.

  14. Sol-gel matrices for direct colorimetric detection of analytes

    DOEpatents

    Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey

    2000-01-01

    The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.

  15. Ytterbium-doped glass-ceramics for optical refrigeration.

    PubMed

    Filho, Elton Soares de Lima; Krishnaiah, Kummara Venkata; Ledemi, Yannick; Yu, Ye-Jin; Messaddeq, Younes; Nemova, Galina; Kashyap, Raman

    2015-02-23

    We report for the first time the characterization of glass-ceramics for optical refrigeration. Ytterbium-doped nanocrystallites were grown in an oxyfluoride glass matrix of composition 2YbF(3):30SiO(2)-15Al(2)O(3)-25CdF(2)-22PbF(2)-4YF(3), forming bulk glass-ceramics at three different crystalisation levels. The samples are compared with a corresponding uncrystalised (glass) sample, as well as a Yb:YAG sample which has presented optical cooling. The measured X-ray diffraction spectra, and thermal capacities of the samples are reported. We also report for the first time the use of Yb:YAG as a reference for absolute photometric quantum efficiency measurement, and use the same setup to characterize the glass and glass-ceramic samples. The cooling figure-of-merit was measured by optical calorimetry using a fiber Bragg grating and found to depend on the level of crystallization of the sample, and that samples with nanocrystallites result in higher quantum efficiency and lower background absorption than the pure-glass sample. In addition to laser-induced cooling, the glass-ceramics have the potential to serve as a reference for quantum efficiency measurements.

  16. Calculation of thermal expansion coefficient of glasses based on topological constraint theory

    NASA Astrophysics Data System (ADS)

    Zeng, Huidan; Ye, Feng; Li, Xiang; Wang, Ling; Yang, Bin; Chen, Jianding; Zhang, Xianghua; Sun, Luyi

    2016-10-01

    In this work, the thermal expansion behavior and the structure configuration evolution of glasses were studied. Degree of freedom based on the topological constraint theory is correlated with configuration evolution; considering the chemical composition and the configuration change, the analytical equation for calculating the thermal expansion coefficient of glasses from degree of freedom was derived. The thermal expansion of typical silicate and chalcogenide glasses was examined by calculating their thermal expansion coefficients (TEC) using the approach stated above. The results showed that this approach was energetically favorable for glass materials and revealed the corresponding underlying essence from viewpoint of configuration entropy. This work establishes a configuration-based methodology to calculate the thermal expansion coefficient of glasses that, lack periodic order.

  17. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    PubMed

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  18. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China

    PubMed Central

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-01-01

    Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390

  19. Glass Ceiling in Academic Administration in Turkey: 1990s versus 2000s

    ERIC Educational Resources Information Center

    Gunluk-Senesen, Gulay

    2009-01-01

    This paper assesses the glass ceiling for academics in the Turkish universities with reference to top administration positions: rectors and deans. Glass ceiling indicators show that the glass ceiling thickened from the 1990s to late 2000s. The findings are discussed against the background of the transformation in the Turkish universities in the…

  20. Case Report: Analytical Electron Microscopy of Lung Granulomas Associated with Exposure to Coating Materials Carried by Glass Wool Fibers

    PubMed Central

    Ferreira, Angela S.; Moreira, Valéria B.; Castro, Marcos César S.; Soares, Porfírio J.; Algranti, Eduardo; Andrade, Leonardo R.

    2010-01-01

    Context Man-made vitreous fibers (MMVFs) are noncrystalline inorganic fibrous material used for thermal and acoustical insulation (e.g., rock wool, glass wool, glass microfibers, and refractory ceramic fibers). Neither epidemiologic studies of human exposure nor animal studies have shown a noticeable hazardous effect of glass wools on health. However, MMVFs have been anecdotally associated with granulomatous lung disease in several case reports. Case presentation Here, we describe the case of a patient with multiple bilateral nodular opacities who was exposed to glass wool fibers and coating materials for 7 years. Bronchoalveolar lavage fluid revealed an increased total cell count (predominantly macrophages) with numerous cytoplasmic particles. Lung biopsy showed peribronchiolar infiltration of lymphoid cells and many foreign-body–type granulomas. Alveolar macrophages had numerous round and elongated platelike particles inside the cytoplasm. X-ray microanalysis of these particles detected mainly oxygen/aluminum/silicon and oxygen/magnesium/silicon, compatible with kaolinite and talc, respectively. No elemental evidence for glass fibers was found in lung biopsy. Discussion The contribution of analytical electron microscopy applied in the lung biopsy was imperative to confirm the diagnosis of pneumoconiosis associated with a complex occupational exposure that included both MMVFs and coating materials. Relevance to clinical or professional practice This case study points out the possible participation of other components (coating materials), beyond MMVFs, in the etiology of pneumoconiosis. PMID:20123612

  1. Analysis and testing of a bridge deck reinforced with GFRP rebars : final report, April 3, 2007.

    DOT National Transportation Integrated Search

    2007-04-03

    The present project had two main objectives, to experimentally and analytically investigate a bridge deck reinforced with glass : fiber reinforced polymer rebars, and to perform durability tests on four rebar types. : An analytical investigation was ...

  2. Modeling and Characterization of Dynamic Failure of Soda-lime Glass Under High Speed Impact

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Wenning N.; Sun, Xin; Chen, Weinong W.

    2012-05-27

    In this paper, the impact-induced dynamic failure of a soda-lime glass block is studied using an integrated experimental/analytical approach. The Split Hopkinson Pressure Bar (SHPB) technique is used to conduct dynamic failure test of soda-lime glass first. The damage growth patterns and stress histories are reported for various glass specimen designs. Making use of a continuum damage mechanics (CDM)-based constitutive model, the initial failure and subsequent stiffness reduction of glass are simulated and investigated. Explicit finite element analyses are used to simulate the glass specimen impact event. A maximum shear stress-based damage evolution law is used in describing the glassmore » damage process under combined compression/shear loading. The impact test results are used to quantify the critical shear stress for the soda-lime glass under examination.« less

  3. Unraveling the evolving nature of gaseous and dissolved carbon dioxide in champagne wines: a state-of-the-art review, from the bottle to the tasting glass.

    PubMed

    Liger-Belair, Gérard; Polidori, Guillaume; Zéninari, Virginie

    2012-06-30

    In champagne and sparkling wine tasting, the concentration of dissolved CO(2) is indeed an analytical parameter of high importance since it directly impacts the four following sensory properties: (i) the frequency of bubble formation in the glass, (ii) the growth rate of rising bubbles, (iii) the mouth feel, and (iv) the nose of champagne, i.e., its so-called bouquet. In this state-of-the-art review, the evolving nature of the dissolved and gaseous CO(2) found in champagne wines is evidenced, from the bottle to the glass, through various analytical techniques. Results obtained concerning various steps where the CO(2) molecule plays a role (from its ingestion in the liquid phase during the fermentation process to its progressive release in the headspace above the tasting glass) are gathered and synthesized to propose a self-consistent and global overview of how gaseous and dissolved CO(2) impact champagne and sparkling wine science. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Augmented reality enabling intelligence exploitation at the edge

    NASA Astrophysics Data System (ADS)

    Kase, Sue E.; Roy, Heather; Bowman, Elizabeth K.; Patton, Debra

    2015-05-01

    Today's Warfighters need to make quick decisions while interacting in densely populated environments comprised of friendly, hostile, and neutral host nation locals. However, there is a gap in the real-time processing of big data streams for edge intelligence. We introduce a big data processing pipeline called ARTEA that ingests, monitors, and performs a variety of analytics including noise reduction, pattern identification, and trend and event detection in the context of an area of operations (AOR). Results of the analytics are presented to the Soldier via an augmented reality (AR) device Google Glass (Glass). Non-intrusive AR devices such as Glass can visually communicate contextually relevant alerts to the Soldier based on the current mission objectives, time, location, and observed or sensed activities. This real-time processing and AR presentation approach to knowledge discovery flattens the intelligence hierarchy enabling the edge Soldier to act as a vital and active participant in the analysis process. We report preliminary observations testing ARTEA and Glass in a document exploitation and person of interest scenario simulating edge Soldier participation in the intelligence process in disconnected deployment conditions.

  5. Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.

    PubMed

    Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka

    2010-05-01

    A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.

  6. Practical automated glass selection and the design of apochromats with large field of view.

    PubMed

    Siew, Ronian

    2016-11-10

    This paper presents an automated approach to the selection of optical glasses for the design of an apochromatic lens with large field of view, based on a design originally provided by Yang et al. [Appl. Opt.55, 5977 (2016)APOPAI0003-693510.1364/AO.55.005977]. Following from this reference's preliminary optimized structure, it is shown that the effort of glass selection is significantly reduced by using the global optimization feature in the Zemax optical design program. The glass selection process is very fast, complete within minutes, and the key lies in automating the substitution of glasses found from the global search without the need to simultaneously optimize any other lens parameter during the glass search. The result is an alternate optimized version of the lens from the above reference possessing zero axial secondary color within the visible spectrum and a large field of view. Supplementary material is provided in the form of Zemax and text files, before and after final optimization.

  7. Direct lead isotope analysis in Hg-rich sulfides by LA-MC-ICP-MS with a gas exchange device and matrix-matched calibration.

    PubMed

    Zhang, Wen; Hu, Zhaochu; Günther, Detlef; Liu, Yongsheng; Ling, Wenli; Zong, Keqing; Chen, Haihong; Gao, Shan

    2016-12-15

    In situ Pb isotope data of sulfide samples measured by LA-MC-ICP-MS provide valuable geochemical information for studies of the origin and evolution of ore deposits. However, the severe isobaric interference of 204 Hg on 204 Pb and the lack of matrix-matched sulfide reference materials limit the precision of Pb isotopic analyses for Hg-rich sulfides. In this study, we observe that Hg forms vapor and can be completely removed from sample aerosol particles produced by laser ablation using a gas exchange device. Additionally, this device does not influence the signal intensities of Pb isotopes. The within-run precision, the external reproducibility and the analytical accuracy are significantly improved for the Hg-rich sulfide samples using this mercury-vapor-removing device. Matrix effects are observed when using silicate glass reference materials as the external standards to assess the relationship of mass fractionation factors between Tl and Pb in sulfide samples, resulting in a maximum deviation of ∼0.20% for 20x Pb/ 204 Pb. Matrix-matched reference materials are therefore required for the highly precise and accurate Pb isotope analyses of sulfide samples. We investigated two sulfide samples, MASS-1 (the Unites States Geological Survey reference materials) and Sph-HYLM (a natural sphalerite), as potential candidates. Repeated analyses of the two proposed sulfide reference materials by LA-MC-ICP-MS yield good external reproducibility of <0.04% (RSD, k = 2) for 20x Pb/ 206 Pb and <0.06% (RSD, k = 2) for 20x Pb/ 204 Pb with the exception of 20x Pb/ 204 Pb in MASS-1, which provided an external reproducibility of 0.24% (RSD, k = 2). Because the concentration of Pb in MASS-1 (76 μg g -1 ) is ∼5.2 times lower than that in Sph-HYLM (394 ± 264 μg g -1 ). The in situ analytical results of MASS-1 and Sph-HYLM are consistent with the values obtained by solution MC-ICP-MS, demonstrating the reliability and robustness of our analytical protocol. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements.

    PubMed

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m(-3) to 180 kg·m(-3), and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: [Formula: see text]where λ(ρ,T) is the predicted thermal conductivity (W·m(-1)·K(-1)), ρ is the bulk density (kg·m(-3)), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. [Formula: see text] One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

  9. Fusion Bead Procedure for Nuclear Forensics Employing Synthetic Enstatite to Dissolve Uraniferous and Other Challenging Materials Prior to Laser Ablation Inductively Coupled Plasma Mass Spectrometry.

    PubMed

    Reading, David G; Croudace, Ian W; Warwick, Phillip E

    2017-06-06

    There is an increasing demand for rapid and effective analytical tools to support nuclear forensic investigations of seized or suspect materials. Some methods are simply adapted from other scientific disciplines and can effectively be used to rapidly prepare complex materials for subsequent analysis. A novel sample fusion method is developed, tested, and validated to produce homogeneous, flux-free glass beads of geochemical reference materials (GRMs), uranium ores, and uranium ore concentrates (UOC) prior to the analysis of 14 rare earth elements (REE) via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The novelty of the procedure is the production of glass beads using 9 parts high purity synthetic enstatite (MgSiO 3 ) as the glass former with 1 part of sample (sample mass ∼1.5 mg). The beads are rapidly prepared (∼10 min overall time) by fusing the blended mixture on an iridium strip resistance heater in an argon-purged chamber. Many elements can be measured in the glass bead, but the rare earth group in particular is a valuable series in nuclear forensic studies and is well-determined using LA-ICP-MS. The REE data obtained from the GRMs, presented as chondrite normalized patterns, are in very good agreement with consensus patterns. The UOCs have comparable patterns to solution ICP-MS methods and published data. The attractions of the current development are its conservation of sample, speed of preparation, and suitability for microbeam analysis, all of which are favorable for nuclear forensics practitioners and geochemists requiring REE patterns from scarce or valuable samples.

  10. Hanford’s Supplemental Treatment Project: Full-Scale Integrated Testing of In-Container-Vitrification and a 10,000-Liter Dryer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witwer, Keith S.; Dysland, Eric J.; Garfield, J. S.

    2008-02-22

    The GeoMelt® In-Container Vitrification™ (ICV™) process was selected by the U.S. Department of Energy (DOE) in 2004 for further evaluation as the supplemental treatment technology for Hanford’s low-activity waste (LAW). Also referred to as “bulk vitrification,” this process combines glass forming minerals, LAW, and chemical amendments; dries the mixture; and then vitrifies the material in a refractory-lined steel container. AMEC Nuclear Ltd. (AMEC) is adapting its GeoMelt ICV™ technology for this application with technical and analytical support from Pacific Northwest National Laboratory (PNNL). The DVBS project is funded by the DOE Office of River Protection and administered by CH2M HILLmore » Hanford Group, Inc. The Demonstration Bulk Vitrification Project (DBVS) was initiated to engineer, construct, and operate a full-scale bulk vitrification pilot-plant to treat up to 750,000 liters of LAW from Waste Tank 241-S-109 at the DOE Hanford Site. Since the beginning of the DBVS project in 2004, testing has used laboratory, crucible-scale, and engineering-scale equipment to help establish process limitations of selected glass formulations and identify operational issues. Full-scale testing has provided critical design verification of the ICV™ process before operating the Hanford pilot-plant. In 2007, the project’s fifth full-scale test, called FS-38D, (also known as the Integrated Dryer Melter Test, or IDMT,) was performed. This test had three primary objectives: 1) Demonstrate the simultaneous and integrated operation of the ICV™ melter with a 10,000-liter dryer, 2) Demonstrate the effectiveness of a new feed reformulation and change in process methodology towards reducing the production and migration of molten ionic salts (MIS), and, 3) Demonstrate that an acceptable glass product is produced under these conditions. Testing was performed from August 8 to 17, 2007. Process and analytical results demonstrated that the primary test objectives, along with a dozen supporting objectives, were successfully met. Glass performance exceeded all disposal performance criteria. A previous issue with MIS containment was successfully resolved in FS-38D, and the ICV™ melter was integrated with a full-scale, 10,000-liter dryer. This paper describes the rationale for performing the test, the purpose and outcome of scale-up tests preceding it, and the performance and outcome of FS-38D.« less

  11. Study on the Strength of GFRP/Stainless Steel Adhesive Joints Reinforced with Glass Mat

    NASA Astrophysics Data System (ADS)

    Iwasa, Masaaki

    The adhesive strengths of glass fiber reinforced plastics/metal adhesive joints reinforced with glass mat under tensile shear loads and tensile loads were investigated analytically and experimentally. First, the stress singularity parameters of the bonding edges were analyzed by FEM for various types of adhesive joints reinforced with glass mat. The shear stress and normal stress distributions near the bonding edge can be expressed by two stress singularity parameters. Second, tensile shear tests were performed on taper lap joint and taper lap joint reinforced with glass mat and tensile tests were performed on T-type adhesive joint and T-type adhesive joint reinforced with glass mat. The relationships between the loads and the crosshead displacements were measured. We concluded that reinforcing adhesive joints has a greater effect on strength under tensile load than under tensile shear load. The adhesive joints strength reinforced with glass mat can be evaluated by using stress singularity parameters.

  12. Radiological analysis of plutonium glass batches with natural/enriched boron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rainisch, R.

    2000-06-22

    The disposition of surplus plutonium inventories by the US Department of Energy (DOE) includes the immobilization of certain plutonium materials in a borosilicate glass matrix, also referred to as vitrification. This paper addresses source terms of plutonium masses immobilized in a borosilicate glass matrix where the glass components include both natural boron and enriched boron. The calculated source terms pertain to neutron and gamma source strength (particles per second), and source spectrum changes. The calculated source terms corresponding to natural boron and enriched boron are compared to determine the benefits (decrease in radiation source terms) for to the use ofmore » enriched boron. The analysis of plutonium glass source terms shows that a large component of the neutron source terms is due to (a, n) reactions. The Americium-241 and plutonium present in the glass emit alpha particles (a). These alpha particles interact with low-Z nuclides like B-11, B-10, and O-17 in the glass to produce neutrons. The low-Z nuclides are referred to as target particles. The reference glass contains 9.4 wt percent B{sub 2}O{sub 3}. Boron-11 was found to strongly support the (a, n) reactions in the glass matrix. B-11 has a natural abundance of over 80 percent. The (a, n) reaction rates for B-10 are lower than for B-11 and the analysis shows that the plutonium glass neutron source terms can be reduced by artificially enriching natural boron with B-10. The natural abundance of B-10 is 19.9 percent. Boron enriched to 96-wt percent B-10 or above can be obtained commercially. Since lower source terms imply lower dose rates to radiation workers handling the plutonium glass materials, it is important to know the achievable decrease in source terms as a result of boron enrichment. Plutonium materials are normally handled in glove boxes with shielded glass windows and the work entails both extremity and whole-body exposures. Lowering the source terms of the plutonium batches will make the handling of these materials less difficult and will reduce radiation exposure to operating workers.« less

  13. 46 CFR 160.048-1 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Specification for a Buoyant Cushion, Fibrous Glass § 160.048-1... documents: (1) Military specification: MIL-B-2766—Batt, Fibrous Glass, Lifesaving Equipment. (2) Federal... issue in effect on the date kapok or fibrous glass buoyant cushions are manufactured, form a part of...

  14. Radiopaque Strontium Fluoroapatite Glass-Ceramics.

    PubMed

    Höland, Wolfram; Schweiger, Marcel; Dittmer, Marc; Ritzberger, Christian

    2015-01-01

    The controlled precipitation of strontium fluoroapatite crystals was studied in four base glass compositions derived from the SiO2-Al2O3-Y2O3-SrO-Na2O-K2O/Rb2O/Cs2O-P2O5-F system. The crystal phase formation of these glasses and the main properties of the glass-ceramics, such as thermal and optical properties and radiopacity were compared with a fifth, a reference glass-ceramic. The reference glass-ceramic was characterized as Ca-fluoroapatite glass-ceramic. The four strontium fluoroapatite glass-ceramics showed the following crystal phases: (a) Sr5(PO4)3F - leucite, KAlSi2O6, (b) Sr5(PO4)3F - leucite, KAlSi2O6, and nano-sized NaSrPO4, (c) Sr5(PO4)3F - pollucite, CsAlSi2O6, and nano-sized NaSrPO4, and (d) Sr5(PO4)3F - Rb-leucite, RbAlSi2O6, and nano-sized NaSrPO4. The proof of crystal phase formation was possible by X-ray diffraction. The microstructures, which were studied using scanning electron microscopy, demonstrated a uniform distribution of the crystals in the glass matrix. The Sr-fluoroapatites were precipitated based on an internal crystallization process, and the crystals demonstrated a needle-like morphology. The study of the crystal growth of needle-like Sr-fluoroapatites gave a clear evidence of an Ostwald ripening mechanism. The formation of leucite, pollucite, and Rb-leucite was based on a surface crystallization mechanism. Therefore, a twofold crystallization mechanism was successfully applied to develop these types of glass-ceramics. The main focus of this study was the controlled development of glass-ceramics exhibiting high radiopacity in comparison to the reference glass-ceramic. This goal could be achieved with all four glass-ceramics with the preferred development of the Sr-fluoroapatite - pollucite-type glass-ceramic. In addition to this main development, it was possible to control the thermal properties. Especially the Rb-leucite containing glass-ceramic showed the highest coefficient of thermal expansion (CTE). These glass-ceramics allow optical properties, especially the translucency and color, to be tailored to the needs of biomaterials for dental applications. The authors conclude that it is possible to use twofold crystallization processes to develop glass-ceramic biomaterials featuring different properties, such as specific radiopacity values, CTEs, and optical characteristics.

  15. Radiopaque Strontium Fluoroapatite Glass-Ceramics

    PubMed Central

    Höland, Wolfram; Schweiger, Marcel; Dittmer, Marc; Ritzberger, Christian

    2015-01-01

    The controlled precipitation of strontium fluoroapatite crystals was studied in four base glass compositions derived from the SiO2–Al2O3–Y2O3–SrO–Na2O–K2O/Rb2O/Cs2O–P2O5–F system. The crystal phase formation of these glasses and the main properties of the glass-ceramics, such as thermal and optical properties and radiopacity were compared with a fifth, a reference glass-ceramic. The reference glass-ceramic was characterized as Ca-fluoroapatite glass-ceramic. The four strontium fluoroapatite glass-ceramics showed the following crystal phases: (a) Sr5(PO4)3F – leucite, KAlSi2O6, (b) Sr5(PO4)3F – leucite, KAlSi2O6, and nano-sized NaSrPO4, (c) Sr5(PO4)3F – pollucite, CsAlSi2O6, and nano-sized NaSrPO4, and (d) Sr5(PO4)3F – Rb-leucite, RbAlSi2O6, and nano-sized NaSrPO4. The proof of crystal phase formation was possible by X-ray diffraction. The microstructures, which were studied using scanning electron microscopy, demonstrated a uniform distribution of the crystals in the glass matrix. The Sr-fluoroapatites were precipitated based on an internal crystallization process, and the crystals demonstrated a needle-like morphology. The study of the crystal growth of needle-like Sr-fluoroapatites gave a clear evidence of an Ostwald ripening mechanism. The formation of leucite, pollucite, and Rb-leucite was based on a surface crystallization mechanism. Therefore, a twofold crystallization mechanism was successfully applied to develop these types of glass-ceramics. The main focus of this study was the controlled development of glass-ceramics exhibiting high radiopacity in comparison to the reference glass-ceramic. This goal could be achieved with all four glass-ceramics with the preferred development of the Sr-fluoroapatite – pollucite-type glass-ceramic. In addition to this main development, it was possible to control the thermal properties. Especially the Rb-leucite containing glass-ceramic showed the highest coefficient of thermal expansion (CTE). These glass-ceramics allow optical properties, especially the translucency and color, to be tailored to the needs of biomaterials for dental applications. The authors conclude that it is possible to use twofold crystallization processes to develop glass-ceramic biomaterials featuring different properties, such as specific radiopacity values, CTEs, and optical characteristics. PMID:26528470

  16. SAMPLING DEVICE FOR pH MEASUREMENT IN PROCESS STREAMS

    DOEpatents

    Michelson, C.E.; Carson, W.N. Jr.

    1958-11-01

    A pH cell is presented for monitoring the hydrogen ion concentration of a fluid in a process stream. The cell is made of glass with a side entry arm just above a reservoir in which the ends of a glass electrode and a reference electrode are situated. The glass electrode contains the usual internal solution which is connected to a lead. The reference electrode is formed of saturated calomel having a salt bridge in its bottom portion fabricated of a porous glass to insure low electrolyte flow. A flush tube leads into the cell through which buffer and flush solutions are introduced. A ground wire twists about both electrode ends to insure constant electrical grounding of the sample. The electrode leads are electrically connected to a pH meter of aay standard type.

  17. Sensors for monitoring waste glass quality and method of using the same

    DOEpatents

    Bickford, Dennis F.

    1994-01-01

    A set of three electrical probes for monitoring alkali and oxygen activity of a glass melt. On-line, real time measurements of the potential difference among the probes when they are placed in electrical contact with the melt yield the activity information and can be used to adjust the composition of the melt in order to produce higher quality glass. The first two probes each has a reference gas and a reference electrolyte and a pair of wires in electrical connection with each other in the reference gas but having one of the wires extending further into the reference electrolyte. The reference gases both include a known concentration of oxygen. The third electrode has a pair of wires extending through an otherwise solid body to join electrically just past the body but having one of the wires extend past this junction. Measuring the potential difference between wires of the first and second probes provides the alkali activity; measurement of the potential difference between wires of the second and third probes provides the oxygen activity of the melt.

  18. Sensors for monitoring waste glass quality and method of using the same

    DOEpatents

    Bickford, D.F.

    1994-03-15

    A set of three electrical probes is described for monitoring alkali and oxygen activity of a glass melt. On-line, real time measurements of the potential difference among the probes when they are placed in electrical contact with the melt yield the activity information and can be used to adjust the composition of the melt in order to produce higher quality glass. The first two probes each has a reference gas and a reference electrolyte and a pair of wires in electrical connection with each other in the reference gas but having one of the wires extending further into the reference electrolyte. The reference gases both include a known concentration of oxygen. The third electrode has a pair of wires extending through an otherwise solid body to join electrically just past the body but having one of the wires extend past this junction. Measuring the potential difference between wires of the first and second probes provides the alkali activity; measurement of the potential difference between wires of the second and third probes provides the oxygen activity of the melt. 1 figure.

  19. Event-by-Event Simulations of Early Gluon Fields in High Energy Nuclear Collisions

    NASA Astrophysics Data System (ADS)

    Nickel, Matthew; Rose, Steven; Fries, Rainer

    2017-09-01

    Collisions of heavy ions are carried out at ultra relativistic speeds at the Relativistic Heavy Ion Collider and the Large Hadron Collider to create Quark Gluon Plasma. The earliest stages of such collisions are dominated by the dynamics of classical gluon fields. The McLerran-Venugopalan (MV) model of color glass condensate provides a model for this process. Previous research has provided an analytic solution for event averaged observables in the MV model. Using the High Performance Research Computing Center (HPRC) at Texas A&M, we have developed a C++ code to explicitly calculate the initial gluon fields and energy momentum tensor event by event using the analytic recursive solution. The code has been tested against previously known analytic results up to fourth order. We have also have been able to test the convergence of the recursive solution at high orders in time and studied the time evolution of color glass condensate.

  20. Bioparticles assembled using low frequency vibration immune to evacuation drifts

    NASA Astrophysics Data System (ADS)

    Shao, Fenfen; Whitehill, James David; Ng, Tuck Wah

    2012-08-01

    The use of low frequency vibration on suspensions of glass beads in a droplet has been shown to develop a strong degree of patterning (to a ring) due to the manner with which the surface waves are modified. Functionalized glass beads that serve as bioparticles permit for sensitive readings when concentrated at specific locations. However, a time controlled exposure with analytes is desirable. The replacement of the liquid medium with analyte through extraction is needed to conserve time. Nevertheless, we show here that extraction with a porous media, which is simple and useable in the field, will strongly displace the patterned beads. The liquid removal was found to be dependent on two mechanisms that affect the shape of the droplet, one of contact hysteresis due to the outer edge pinning, and the other of liquid being drawn into the porous media. From this, we developed and demonstrated a modified well structure that prevented micro-bead displacement during evacuation. An added strong advantage with this approach lies with its ability to require only analytes to be dispensed at the location of aggregated particles, which minimizes analyte usage. This was analytically established here.

  1. Bio-Based Nanocomposites: An Alternative to Traditional Composites

    ERIC Educational Resources Information Center

    Tate, Jitendra S.; Akinola, Adekunle T.; Kabakov, Dmitri

    2009-01-01

    Polymer matrix composites (PMC), often referred to as fiber reinforced plastics (FRP), consist of fiber reinforcement (E-glass, S2-glass, aramid, carbon, or natural fibers) and polymer matrix/resin (polyester, vinyl ester, polyurethane, phenolic, and epoxies). Eglass/ polyester and E-glass/vinyl ester composites are extensively used in the marine,…

  2. Glass binder development for a glass-bonded sodalite ceramic waste form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, Brian J.; Vienna, John D.; Frank, Steven M.

    This paper discusses work to develop Na2O-B2O3-SiO2 glass binders for immobilizing LiCl-KCl eutectic salt waste in a glass-bonded sodalite waste form following electrochemical reprocessing of used metallic nuclear fuel. Here, five new glasses with high Na2O contents were designed to generate waste forms having higher sodalite contents and fewer stress fractures. The structural, mechanical, and thermal properties of the new glasses were measured using variety of analytical techniques. The glasses were then used to produce ceramic waste forms with surrogate salt waste. The materials made using the glasses developed during this study were formulated to generate more sodalite than materialsmore » made with previous baseline glasses used. The coefficients of thermal expansion for the glass phase in the glass-bonded sodalite waste forms made with the new binder glasses were closer to the sodalite phase in the critical temperature region near and below the glass transition temperature. These improvements should result in lower probability of cracking in the full-scale monolithic ceramic waste form, leading to better long-term chemical durability. Additionally, a model generated during this study for predicting softening temperature of silicate binder glasses is presented.« less

  3. Assessment of sample preservation techniques for pharmaceuticals, personal care products, and steroids in surface and drinking water.

    PubMed

    Vanderford, Brett J; Mawhinney, Douglas B; Trenholm, Rebecca A; Zeigler-Holady, Janie C; Snyder, Shane A

    2011-02-01

    Proper collection and preservation techniques are necessary to ensure sample integrity and maintain the stability of analytes until analysis. Data from improperly collected and preserved samples could lead to faulty conclusions and misinterpretation of the occurrence and fate of the compounds being studied. Because contaminants of emerging concern, such as pharmaceuticals and personal care products (PPCPs) and steroids, generally occur in surface and drinking water at ng/L levels, these compounds in particular require such protocols to accurately assess their concentrations. In this study, sample bottle types, residual oxidant quenching agents, preservation agents, and hold times were assessed for 21 PPCPs and steroids in surface water and finished drinking water. Amber glass bottles were found to have the least effect on target analyte concentrations, while high-density polyethylene bottles had the most impact. Ascorbic acid, sodium thiosulfate, and sodium sulfite were determined to be acceptable quenching agents and preservation with sodium azide at 4 °C led to the stability of the most target compounds. A combination of amber glass bottles, ascorbic acid, and sodium azide preserved analyte concentrations for 28 days in the tested matrices when held at 4 °C. Samples without a preservation agent were determined to be stable for all but two of the analytes when stored in amber glass bottles at 4 °C for 72 h. Results suggest that if improper protocols are utilized, reported concentrations of target PPCPs and steroids may be inaccurate.

  4. Description of Defense Waste Processing Facility reference waste form and canister. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, R.G.

    1983-08-01

    The Defense Waste Processing Facility (DWPF) will be located at the Savannah River Plant in Aiken, SC, and is scheduled for construction authorization during FY-1984. The reference waste form is borosilicate glass containing approx. 28 wt % sludge oxides, with the balance glass frit. Borosilicate glass was chosen because of its high resistance to leaching by water, its relatively high solubility for nuclides found in the sludge, and its reasonably low melting temperature. The glass frit contains about 58% SiO/sub 2/ and 15% B/sub 2/O/sub 3/. Leachabilities of SRP waste glasses are expected to approach 10/sup -8/ g/m/sup 2/-day basedmore » upon 1000-day tests using glasses containing SRP radioactive waste. Tests were performed under a wide variety of conditions simulating repository environments. The canister is filled with 3260 lb of glass which occupies about 85% of the free canister volume. The filled canister will generate approx. 470 watts when filled with oxides from 5-year-old sludge and 15-year-old supernate from the sludge and supernate processes. The radionuclide content of the canister is about 177,000 ci, with a radiation level of 5500 rem/h at canister surface contact. The reference canister is fabricated of standard 24-in.-OD, Schedule 20, 304L stainless steel pipe with a dished bottom, domed head, and a combined lifting and welding flange on the head neck. The overall canister length is 9 ft 10 in. with a 3/8-in. wall thickness. The 3-m canister length was selected to reduce equipment cell height in the DWPF to a practical size. The canister diameter was selected as an optimum size from glass quality considerations, a logical size for repository handling and to ensure that a filled canister with its double containment shipping cask could be accommodated on a legal-weight truck. The overall dimensions and weight appear to be compatible with preliminary assessments of repository requirements. 10 references.« less

  5. Material, process, and product design of thermoplastic composite materials

    NASA Astrophysics Data System (ADS)

    Dai, Heming

    Thermoplastic composites made of polypropylene (PP) and E-glass fibers were investigated experimentally as well as theoretically for two new classes of product designs. The first application was for reinforcement of wood. Commingled PP/glass yarn was consolidated and bonded on wood panel using a tie layer. The processing parameters, including temperature, pressure, heating time, cooling time, bonding strength, and bending strength were tested experimentally and evaluated analytically. The thermoplastic adhesive interface was investigated with environmental scanning electron microscopy. The wood/composite structural design was optimized and evaluated using a Graphic Method. In the second application, we evaluated use of thermoplastic composites for explosion containment in an arrester. PP/glass yarn was fabricated in a sleeve form and wrapped around the arrester. After consolidation, the flexible composite sleeve forms a solid composite shell. The composite shell acts as a protection layer in a surge test to contain the fragments of the arrester. The manufacturing process for forming the composite shell was designed. Woven, knitted, and braided textile composite shells made of commingled PP/glass yarn were tested and evaluated. Mechanical performance of the woven, knitted, and braided composite shells was examined analytically. The theoretical predictions were used to verify the experimental results.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Semenov, A. N.

    We propose a new spin-glass model with no positional quenched disorder which is regarded as a coarse-grained model of a structural glass-former. The model is analyzed in the 1D case when the number N of states of a primary cell is large. For N → ∞, the model exhibits a sharp freezing transition of the thermodynamic origin. It is shown both analytically and numerically that the glass transition is accompanied by a significant growth of a static length scale ξ pointing to the structural (equilibrium) nature of dynamical slowdown effects in supercooled liquids.

  7. Valid analytical performance specifications for combined analytical bias and imprecision for the use of common reference intervals.

    PubMed

    Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György

    2018-01-01

    Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.

  8. Thermodynamic model of natural, medieval and nuclear waste glass durability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jantzen, C.M.; Plodinec, M.J.

    1983-01-01

    A thermodynamic model of glass durability based on hydration of structural units has been applied to natural glass, medieval window glasses, and glasses containing nuclear waste. The relative durability predicted from the calculated thermodynamics correlates directly with the experimentally observed release of structural silicon in the leaching solution in short-term laboratory tests. By choosing natural glasses and ancient glasses whose long-term performance is known, and which bracket the durability of waste glasses, the long-term stability of nuclear waste glasses can be interpolated among these materials. The current Savannah River defense waste glass formulation is as durable as natural basalt frommore » the Hanford Reservation (10/sup 6/ years old). The thermodynamic hydration energy is shown to be related to the bond energetics of the glass. 69 references, 2 figures, 1 table.« less

  9. Investigations of Archaeological Glass Bracelets and Perfume Bottles Excavated in Ancient Ainos (Enez) by Multiple Analytical Techniques

    NASA Astrophysics Data System (ADS)

    Celik, S.; Akyuz, T.; Akyuz, S.; Ozel, A. E.; Kecel-Gunduz, S.; Basaran, S.

    2018-03-01

    Fragments of two perfume bottles belonging to the Hellenistic and Roman periods, and five bracelets belonging to the Roman, Byzantine, and Ottoman periods, excavated in the archaeological site of Enez during the excavations in 2000, have been investigated. The samples were analyzed using micro-Raman, FTIR, and energy dispersive X-ray fluorescence techniques, in order to study the ancient technology of glass production and to determine chemical compositions of the basic components and coloring elements of the glassware. All the investigated glasses can be characterized as low-magnesia-soda-lime silicate glasses, whose colors are induced by metal ions. The melting points of the investigated glasses are estimated to be quite close to each other and around 1000°C.

  10. Determination of Trace and Volatile Element Abundance Systematics of Lunar Pyroclastic Glasses 74220 and 15426 Using LA-ICP-MS

    NASA Technical Reports Server (NTRS)

    McIntosh, E. Carrie; Porrachia, Magali; McCubbin, Francis M.; Day, James M. D.

    2017-01-01

    Since their recognition as pyroclastic glasses generated by volcanic fire fountaining on the Moon, 74220 and 15426 have garnered significant scientific interest. Early studies recognized that the glasses were particularly enriched in volatile elements on their surfaces. More recently, detailed analyses of the interiors of the glasses, as well as of melt inclusions within olivine grains associated with the 74220 glass beads, have determined high H2O, F, Cl and S contents. Such elevated volatile contents seem at odds with evidence from moderately volatile elements (MVE), such as Zn and K, for a volatile- depleted Moon. In this study, we present initial results from an analytical campaign to study trace element abundances within the pyroclastic glass beads. We report trace element data determined by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for 15426 and 74220.

  11. Optical distortion correction of a liquid-gas interface and contact angle in cylindrical tubes

    NASA Astrophysics Data System (ADS)

    Darzi, Milad; Park, Chanwoo

    2017-05-01

    Objects inside cylindrical tubes appear distorted as seen outside the tube due to the refraction of the light passing through different media. Such an optical distortion may cause significant errors in geometrical measurements using optical observations of objects (e.g., liquid-gas interfaces, solid particles, gas bubbles) inside the tubes. In this study, an analytical method using a point-by-point correction of the optical distortion was developed. For an experimental validation, the method was used to correct the apparent profiles of the water-air interfaces (menisci) in cylindrical glass tubes with different tube diameters and wall thicknesses. Then, the corrected meniscus profiles were used to calculate the corrected static contact angles. The corrected contact angle shows an excellent agreement with the reference contact angles as compared to the conventional contact angle measurement using apparent meniscus profiles.

  12. Glass Doesn't Flow and Doesn't Crystallize and It Isn't a Liquid.

    ERIC Educational Resources Information Center

    Hawkes, Stephen J.

    2000-01-01

    Illustrates that, contrary to some assertions made in the popular press, scientific literature, and introductory textbooks, glass does not flow in historic time. Contends that glass is a rigid solid with a lower degree of molecular order than a crystal but with greater molecular order than a liquid. (Contains 27 references.) (WRM)

  13. Underrepresentation of Females in the Superintendency in Minnesota

    ERIC Educational Resources Information Center

    Wyland, Catherine

    2016-01-01

    Public school district leadership is dominated by males while teaching is dominated by females (Blount, 1998; Glass, Björk, & Brunner, 2000; Grogan, 1996). Some may not recognize this as a problem while others might refer to this underrepresentation as a glass ceiling, a sticky floor, a concrete wall, or a glass cliff. In any case, the…

  14. Evaluation of cellular glasses for solar mirror panel applications

    NASA Technical Reports Server (NTRS)

    Giovan, M.; Adams, M.

    1979-01-01

    An analytic technique was developed to compare the structural and environmental performance of various materials considered for backing of second surface glass solar mirrors. Cellular glass was determined to be a prime candidate due to its low cost, high stiffness-to-weight ratio, thermal expansion match to mirror glass, evident minimal environmental impact and chemical and dimensional stability under conditions of use. The current state of the art and anticipated developments in cellular glass technology are discussed; material properties are correlated to design requirements. A mathematical model is presented which suggests a design approach which allows minimization of life cost; and, a mechanical and environmental testing program is outlined, designed to provide a material property basis for development of cellular glass hardware, together with methodology for collecting lifetime predictive data. Preliminary material property data from measurements are given. Microstructure of several cellular materials is shown, and sensitivity of cellular glass to freeze-thaw degradation and to slow crack growth is discussed. The effect of surface coating is addressed.

  15. Bulk Formation of Metallic Glasses and Amorphous Silicon from the Melt

    NASA Technical Reports Server (NTRS)

    Spaepen, F.

    1985-01-01

    By using metallic glass compositions with a high relative glass transition temperature, such as Pd40Ni40P20, homogeneous nucleation also becomes negligible. Large (5g) masses of this alloys were obtained using a molten B2O3 flux. Presently, bulk glass formation in iron based glasses is being investigated. It is expected that if an undercooling of about 250K can be achieved in a Ge or Si melt, formation of the amorphous semiconductor phase (rather than the crystal) may be kinetically favored. The volumetric behavior of undercooled liquid Ga droplet dispersion is investigated by dilatometry. A theoretical model (both analytical and numerical) was developed for transient nucleation in glass forming melts. The model, originally designed for isothermal conditions, was extended to continuous quenching. It is being applied to glass formation in various metallic and oxide systems. A further refinement will be the inclusion of diffusion controlled interfacial rearrangements governing the growth of the crystal embryos.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Addleman, Raymond S; Atkinson, David A; Bays, John T

    An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.

  17. Workshop on Future Directions for Optical Information Processing.

    DTIC Science & Technology

    1981-03-01

    h . The i reference point source simultaneously illuminates the i member of a family of n phase-encoding Aiffusers (e.g. shower glass , ground glass ...diffuser (ground glass ) section illuminated with a plane wave [35.37). The n(n-1) - 4(3) - 12 crosstalk terms have been distributed into the noise...for 2x2 input Fig. 6. Outnut of processor analogous to that array, l.Sx magnifier, ground glass diffuser of Fig. 5, but using spherical wavefront and

  18. Analytic implementation of the GRAAL model: Application to a R7T7-type glass package in a geological disposal environment

    NASA Astrophysics Data System (ADS)

    Minet, Y.; Bonin, B.; Gin, S.; Frugier, P.

    2010-09-01

    The Glass Reactivity with Allowance for the Alteration Layer Model (GRAAL) was proposed in 2008 to describe borosilicate nuclear glass alteration based on coupling an affinity law with the formation and dissolution of a passivating reactive interface. It is examined here in a simplified form in which only the affinity with respect to silicon is taken into account with a concentration at saturation Csat, and the precipitation of neoformed phases is described by an affine relation for silicon above a precipitation threshold Csat'. This simplified "analytical GRAAL" model is capable of predicting the quantities of altered glass and the silicon and boron concentration variations in analytical or semi-analytical form, and thereby identify the main characteristic quantities of the system. The model was tested against a series of laboratory experiments lasting from a few days to a few years; its sensitivity to the parameter values was examined, and the model was validated with respect to SON68 glass alteration in initially pure water. It was then applied to the alteration of a glass package in a repository over periods of up to a million years, by means of exploratory calculations comprising a sensitivity study of the internal model parameters and extrapolation to the temperatures expected in a geological repository in order to identify the parameters and mechanisms having the greatest impact on the residual alteration rate. Alteration is controlled by the precipitation of neoformed phases in every case. The transient conditions are of very limited duration with respect to either silicon or boron (no more than a 100 years, with less than 0.01% alteration of the package). In the precipitation law used in the model, the residual alteration rate and total package lifetime are determined primarily by two parameters: k' (the precipitation kinetics) and σ' (the precipitate surface area per unit volume in the geological barrier). The package lifetime is about 3 × 10 5 years at 30 °C assuming a reasonable value for σ' (10 6 m -1), and would be increased by a factor 3-6 if precipitation in the barrier were disregarded. This cursory description of precipitation will be validated and refined through specific laboratory tests at 50 °C and lower temperatures, coordinated with the development of the "geochemical GRAAL" model and with integral tests in contact with clay and canister corrosion products.

  19. Bias Assessment of General Chemistry Analytes using Commutable Samples.

    PubMed

    Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter

    2014-11-01

    Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.

  20. Eliminating the use of intravenous glass bottles using a FOCUS-PDCA model and providing a practical stability reference guide.

    PubMed

    Maraiki, Fatma; Farooq, Faiyaz; Ahmed, Mohamed

    2016-08-01

    To identify the intravenous (IV) medications that are prepared in glass bottles at the institution and establish which of these medications can be prepared in flexible IV bags such as polyvinyl chloride (PVC) or non-PVC instead of glass bottles. The cost implication of switching from glass bottles to flexible IV bags was calculated. A study using FOCUS-PDCA model to identify IV medications prepared in glass bottles and establish which of these medications could be prepared in IV bags (PVC or non-PVC). The cost impact of switching from glass bottles to IV plastic bags (including PVC or non-PVC) was calculated. The stability data obtained were used as a reference for updating pharmacy internal IV preparation charts. A total of 17 IV medications were found to be prepared in IV glass bottles. Of these 17 medications, only 8 (47%) were prepared in IV glass bottles due to incompatibility with PVC bags. For 7 (41%) of the medications, of which 6 were monoclonal antibodies (MABs), the reason for preparation in glass bottles was unclear as these medications are compatible with either PVC or non-PVC or both. The potential cost savings associated with switching all of the identified medications to IV plastic bags (either non-PVC or PVC) exceeded $200 000. The elimination of glass bottles within the institution resulted in a significant cost saving. The use of FOCUS-PDCA model can help healthcare institution achieve significant improvements in process and realize significant cost savings. © 2016 Royal Pharmaceutical Society.

  1. Optics survivability support, volume 2

    NASA Astrophysics Data System (ADS)

    Wild, N.; Simpson, T.; Busdeker, A.; Doft, F.

    1993-01-01

    This volume of the Optics Survivability Support Final Report contains plots of all the data contained in the computerized Optical Glasses Database. All of these plots are accessible through the Database, but are included here as a convenient reference. The first three pages summarize the types of glass included with a description of the radiation source, test date, and the original data reference. This information is included in the database as a macro button labeled 'LLNL DATABASE'. Following this summary is an Abbe chart showing which glasses are included and where they lie as a function of nu(sub d) and n(sub d). This chart is also callable through the database as a macro button labeled 'ABBEC'.

  2. Soft modes in the perceptron model for jamming.

    NASA Astrophysics Data System (ADS)

    Franz, Silvio

    I will show how a well known neural network model \\x9Dthe perceptro provides a simple solvable model of glassy behavior and jamming. The glassy minima of the energy function of this model can be studied in full analytic detail. This allows the identification of two kind of soft modes the first ones associated to the existence a marginal glass phase and a hierarchical structure of the energy landscape, the second ones associated to isostaticity and marginality of jamming. These results highlight the universality of the spectrum of normal modes in disordered systems, and open the way toward a detailed analytical understanding of the vibrational spectrum of low-temperature glasses. This work was supported by a Grant from the Simons Foundation (454941 to Silvio Franz).

  3. Analytical and experimental investigation of the coaxial plasma gun for use as a particle accelerator

    NASA Technical Reports Server (NTRS)

    Shriver, E. L.

    1972-01-01

    The coaxial plasma accelerator for use as a projectile accelerator is discussed. The accelerator is described physically and analytically by solution of circuit equations, and by solving for the magnetic pressures which are formed by the j cross B vector forces on the plasma. It is shown that the plasma density must be increased if the accelerator is to be used as a projectile accelerator. Three different approaches to increasing plasma density are discussed. When a magnetic field containment scheme was used to increase the plasma density, glass beads of 0.66 millimeter diameter were accelerated to 7 to 8 kilometers per second velocities. Glass beads of smaller diameter were accelerated to more than twice this velocity.

  4. Bridging Intuitive and Analytical Thinking: Four Looks at the 2-Glass Puzzle

    ERIC Educational Resources Information Center

    Ejersbo, Lisser Rye; Leron, Uri; Arcavi, Abraham

    2014-01-01

    The observation that the human mind operates in two distinct thinking modes--intuitive and analytical- have occupied psychological and educational researchers for several decades now. Much of this research has focused on the explanatory power of intuitive thinking as source of errors and misconceptions, but in this article, in contrast, we view…

  5. Pipelines of Progress: An Update on the Glass Ceiling Initiative. A Status Report.

    ERIC Educational Resources Information Center

    Department of Labor, Washington, DC.

    The "glass ceiling" refers to those barriers that have prevented the advancement of women and minorities into the top levels of executive management in major U.S. corporations. In 1991, the U.S. Department of Labor released a report describing the Glass Ceiling Initiative. This document reports on what occurred in the year following the…

  6. A Randomized Study Comparing Digital Imaging to Traditional Glass Slide Microscopy for Breast Biopsy and Cancer Diagnosis.

    PubMed

    Elmore, Joann G; Longton, Gary M; Pepe, Margaret S; Carney, Patricia A; Nelson, Heidi D; Allison, Kimberly H; Geller, Berta M; Onega, Tracy; Tosteson, Anna N A; Mercan, Ezgi; Shapiro, Linda G; Brunyé, Tad T; Morgan, Thomas R; Weaver, Donald L

    2017-01-01

    Digital whole slide imaging may be useful for obtaining second opinions and is used in many countries. However, the U.S. Food and Drug Administration requires verification studies. Pathologists were randomized to interpret one of four sets of breast biopsy cases during two phases, separated by ≥9 months, using glass slides or digital format (sixty cases per set, one slide per case, n = 240 cases). Accuracy was assessed by comparing interpretations to a consensus reference standard. Intraobserver reproducibility was assessed by comparing the agreement of interpretations on the same cases between two phases. Estimated probabilities of confirmation by a reference panel (i.e., predictive values) were obtained by incorporating data on the population prevalence of diagnoses. Sixty-five percent of responding pathologists were eligible, and 252 consented to randomization; 208 completed Phase I (115 glass, 93 digital); and 172 completed Phase II (86 glass, 86 digital). Accuracy was slightly higher using glass compared to digital format and varied by category: invasive carcinoma, 96% versus 93% ( P = 0.04); ductal carcinoma in situ (DCIS), 84% versus 79% ( P < 0.01); atypia, 48% versus 43% ( P = 0.08); and benign without atypia, 87% versus 82% ( P < 0.01). There was a small decrease in intraobserver agreement when the format changed compared to when glass slides were used in both phases ( P = 0.08). Predictive values for confirmation by a reference panel using glass versus digital were: invasive carcinoma, 98% and 97% (not significant [NS]); DCIS, 70% and 57% ( P = 0.007); atypia, 38% and 28% ( P = 0.002); and benign without atypia, 97% and 96% (NS). In this large randomized study, digital format interpretations were similar to glass slide interpretations of benign and invasive cancer cases. However, cases in the middle of the spectrum, where more inherent variability exists, may be more problematic in digital format. Future studies evaluating the effect these findings exert on clinical practice and patient outcomes are required.

  7. Capillary waveguide optrodes: an approach to optical sensing in medical diagnostics

    NASA Astrophysics Data System (ADS)

    Lippitsch, Max E.; Draxler, Sonja; Kieslinger, Dietmar; Lehmann, Hartmut; Weigl, Bernhard H.

    1996-07-01

    Glass capillaries with a chemically sensitive coating on the inner surface are used as optical sensors for medical diagnostics. A capillary simultaneously serves as a sample compartment, a sensor element, and an inhomogeneous optical waveguide. Various detection schemes based on absorption, fluorescence intensity, or fluorescence lifetime are described. In absorption-based capillary waveguide optrodes the absorption in the sensor layer is analyte dependent; hence light transmission along the inhomogeneous waveguiding structure formed by the capillary wall and the sensing layer is a function of the analyte concentration. Similarly, in fluorescence-based capillary optrodes the fluorescence intensity or the fluorescence lifetime of an indicator dye fixed in the sensing layer is analyte dependent; thus the specific property of fluorescent light excited in the sensing layer and thereafter guided along the inhomogeneous waveguiding structure is a function of the analyte concentration. Both schemes are experimentally demonstrated, one with carbon dioxide as the analyte and the other one with oxygen. The device combines optical sensors with the standard glass capillaries usually applied to gather blood drops from fingertips, to yield a versatile diagnostic instrument, integrating the sample compartment, the optical sensor, and the light-collecting optics into a single piece. This ensures enhanced sensor performance as well as improved handling compared with other sensors. waveguide, blood gases, medical diagnostics.

  8. Antarctic ice-core water (USGS49) – A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.

    2017-01-01

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.

  9. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in April 2001

    USGS Publications Warehouse

    Woodworth, M.T.; Connor, B.F.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  10. Results of the U. S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2002

    USGS Publications Warehouse

    Woodworth, M.T.; Conner, B.F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T- 169 (trace constituents), M- 162 (major constituents), N-73 (nutrient constituents), N-74 (nutrient constituents), P-38 (low ionic-strength constituents), and Hg-34 (mercury) -- that were distributed in March 2002 to laboratories enrolled in the U.S. Geological Survey sponsored intedaboratory testing program. Analytical data received from 93 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  11. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2002

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  12. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2001

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  13. Results of the U.S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2000

    USGS Publications Warehouse

    Farrar, Jerry W.; Copen, Ashley M.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  14. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 1999

    USGS Publications Warehouse

    Farrar, T.W.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  15. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in March 2003

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  16. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 2000

    USGS Publications Warehouse

    Connor, B.F.; Currier, J.P.; Woodworth, M.T.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  17. Glass composition and solution speciation effects on stage III dissolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trivelpiece, Cory L.; Rice, Jarret A.; Pantano, Carlo G.

    To understand and mitigate the onset of Stage III corrosion of multicomponent oxides waste glasses. Stage III refers to a resumption of the high initial rate of glass dissolution in some glass samples that have otherwise exhibited dissolution at the much lower residual rate for a long time (Stage II). Although the onset of Stage III is known to occur concurrently with the precipitation of particular alteration products, the root cause of the transition is still unknown. Certain glass compositions (notably AFCI) and high pH environmental conditions are also associated with this observed transition.

  18. Characterization of the structure of low-e substrates and consequences for IR transflection measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVetter, Brent M.; Kenkel, Seth; Mittal, Shachi

    Spectral distortions caused by the electric field standing wave effect were investigated for two commonly used reflective substrates: low-emissivity glass and gold-coated glass. Our analytical calculations showed that spectral distortions may arise for both incoherent and coherent light sources when performing transflectance measurements. We experimentally confirmed our predictions using a commercial mid-infrared quantum cascade laser microscope and an interferometric infrared imaging system.

  19. ANALYTICAL PLANS SUPPORTING THE SWPF GAP ANALYSIS BEING CONDUCTED WITH ENERGYSOLUTIONS AND THE VITREOUS STATE LABORATORY AT THE CUA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Peeler, D.

    2014-10-28

    EnergySolutions (ES) and its partner, the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA), are to provide engineering and technical services support to Savannah River Remediation, LLC (SRR) for ongoing operation of the Defense Waste Processing Facility (DWPF) flowsheet as well as for modifications to improve overall plant performance. SRR has requested that the glass formulation team of Savannah River National Laboratory (SRNL) and ES-VSL develop a technical basis that validates the current Product Composition Control System models for use during the processing of the coupled flowsheet or that leads to the refinements of or modifications tomore » the models that are needed so that they may be used during the processing of the coupled flowsheet. SRNL has developed a matrix of test glasses that are to be batched and fabricated by ES-VSL as part of this effort. This document provides two analytical plans for use by ES-VSL: one plan is to guide the measurement of the chemical composition of the study glasses while the second is to guide the measurement of the durability of the study glasses based upon the results of testing by ASTM’s Product Consistency Test (PCT) Method A.« less

  20. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cahoon, Erica M.; Almirall, Jose R.

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and themore » mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.« less

  1. Transmission geometry laserspray ionization vacuum using an atmospheric pressure inlet.

    PubMed

    Lutomski, Corinne A; El-Baba, Tarick J; Inutan, Ellen D; Manly, Cory D; Wager-Miller, James; Mackie, Ken; Trimpin, Sarah

    2014-07-01

    This represents the first report of laserspray ionization vacuum (LSIV) with operation directly from atmospheric pressure for use in mass spectrometry. Two different types of electrospray ionization source inlets were converted to LSIV sources by equipping the entrance of the atmospheric pressure inlet aperture with a customized cone that is sealed with a removable glass plate holding the matrix/analyte sample. A laser aligned in transmission geometry (at 180° relative to the inlet) ablates the matrix/analyte sample deposited on the vacuum side of the glass slide. Laser ablation from vacuum requires lower inlet temperature relative to laser ablation at atmospheric pressure. However, higher inlet temperature is required for high-mass analytes, for example, α-chymotrypsinogen (25.6 kDa). Labile compounds such as gangliosides and cardiolipins are detected in the negative ion mode directly from mouse brain tissue as intact doubly deprotonated ions. Multiple charging enhances the ion mobility spectrometry separation of ions derived from complex tissue samples.

  2. Transmission Geometry Laserspray Ionization Vacuum Using an Atmospheric Pressure Inlet

    PubMed Central

    2015-01-01

    This represents the first report of laserspray ionization vacuum (LSIV) with operation directly from atmospheric pressure for use in mass spectrometry. Two different types of electrospray ionization source inlets were converted to LSIV sources by equipping the entrance of the atmospheric pressure inlet aperture with a customized cone that is sealed with a removable glass plate holding the matrix/analyte sample. A laser aligned in transmission geometry (at 180° relative to the inlet) ablates the matrix/analyte sample deposited on the vacuum side of the glass slide. Laser ablation from vacuum requires lower inlet temperature relative to laser ablation at atmospheric pressure. However, higher inlet temperature is required for high-mass analytes, for example, α-chymotrypsinogen (25.6 kDa). Labile compounds such as gangliosides and cardiolipins are detected in the negative ion mode directly from mouse brain tissue as intact doubly deprotonated ions. Multiple charging enhances the ion mobility spectrometry separation of ions derived from complex tissue samples. PMID:24896880

  3. Microchip electrophoresis with electrochemical detection for the determination of analytes in the dopamine metabolic pathway

    PubMed Central

    Saylor, Rachel A.; Reid, Erin A.; Lunte, Susan M.

    2016-01-01

    A method for the separation and detection of analytes in the dopamine metabolic pathway was developed using microchip electrophoresis with electrochemical detection. The microchip consisted of a 5 cm PDMS separation channel in a simple-t configuration. Analytes in the dopamine metabolic pathway were separated using a background electrolyte composed of 15 mM phosphate at pH 7.4, 15 mM SDS, and 2.5 mM boric acid. Two different microchip substrates using different electrode materials were compared for the analysis: a PDMS/PDMS device with a carbon fiber electrode and a PDMS/glass hybrid device with a pyrolyzed photoresist film carbon electrode. While the PDMS/PDMS device generated high separation efficiencies and good resolution, more reproducible migration times were obtained with the PDMS/glass hybrid device, making it a better choice for biological applications. Lastly, the optimized method was used to monitor L-DOPA metabolism in a rat brain slice. PMID:25958983

  4. Development of synthetic nuclear melt glass for forensic analysis.

    PubMed

    Molgaard, Joshua J; Auxier, John D; Giminaro, Andrew V; Oldham, C J; Cook, Matthew T; Young, Stephen A; Hall, Howard L

    A method for producing synthetic debris similar to the melt glass produced by nuclear surface testing is demonstrated. Melt glass from the first nuclear weapon test (commonly referred to as trinitite) is used as the benchmark for this study. These surrogates can be used to simulate a variety of scenarios and will serve as a tool for developing and validating forensic analysis methods.

  5. Hanford's Supplemental Treatment Project: Full-Scale Integrated Testing of In-Container-Vitrification and a 10,000-Liter Dryer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witwer, K.S.; Dysland, E.J.; Garfield, J.S.

    2008-07-01

    The GeoMelt{sup R} In-Container Vitrification{sup TM} (ICV{sup TM}) process was selected by the U.S. Department of Energy (DOE) in 2004 for further evaluation as the supplemental treatment technology for Hanford's low-activity waste (LAW). Also referred to as 'bulk vitrification', this process combines glass forming minerals, LAW, and chemical amendments; dries the mixture; and then vitrifies the material in a refractory-lined steel container. AMEC Nuclear Ltd. (AMEC) is adapting its GeoMelt ICV{sup TM} technology for this application with technical and analytical support from Pacific Northwest National Laboratory (PNNL). The DVBS project is funded by the DOE Office of River Protection andmore » administered by CH2M HILL Hanford Group, Inc. The Demonstration Bulk Vitrification Project (DBVS) was initiated to engineer, construct, and operate a full-scale bulk vitrification pilot-plant to treat up to 750,000 liters of LAW from Waste Tank 241-S-109 at the DOE Hanford Site. Since the beginning of the DBVS project in 2004, testing has used laboratory, crucible-scale, and engineering-scale equipment to help establish process limitations of selected glass formulations and identify operational issues. Full-scale testing has provided critical design verification of the ICV{sup TM} process before operating the Hanford pilot-plant. In 2007, the project's fifth full-scale test, called FS-38D, (also known as the Integrated Dryer Melter Test, or IDMT,) was performed. This test had three primary objectives: 1) Demonstrate the simultaneous and integrated operation of the ICV{sup TM} melter with a 10,000- liter dryer, 2) Demonstrate the effectiveness of a new feed reformulation and change in process methodology towards reducing the production and migration of molten ionic salts (MIS), and, 3) Demonstrate that an acceptable glass product is produced under these conditions. Testing was performed from August 8 to 17, 2007. Process and analytical results demonstrated that the primary test objectives, along with a dozen supporting objectives, were successfully met. Glass performance exceeded all disposal performance criteria. A previous issue with MIS containment was successfully resolved in FS-38D, and the ICV{sup TM} melter was integrated with a full-scale, 10,000-liter dryer. This paper describes the rationale for performing the test, the purpose and outcome of scale-up tests preceding it, and the performance and outcome of FS-38D. (authors)« less

  6. Determining Kinetic Parameters for Isothermal Crystallization of Glasses

    NASA Technical Reports Server (NTRS)

    Ray, C. S.; Zhang, T.; Reis, S. T.; Brow, R. K.

    2006-01-01

    Non-isothermal crystallization techniques are frequently used to determine the kinetic parameters for crystallization in glasses. These techniques are experimentally simple and quick compared to the isothermal techniques. However, the analytical models used for non-isothermal data analysis, originally developed for describing isothermal transformation kinetics, are fundamentally flawed. The present paper describes a technique for determining the kinetic parameters for isothermal crystallization in glasses, which eliminates most of the common problems that generally make the studies of isothermal crystallization laborious and time consuming. In this technique, the volume fraction of glass that is crystallized as a function of time during an isothermal hold was determined using differential thermal analysis (DTA). The crystallization parameters for the lithium-disilicate (Li2O.2SiO2) model glass were first determined and compared to the same parameters determined by other techniques to establish the accuracy and usefulness of the present technique. This technique was then used to describe the crystallization kinetics of a complex Ca-Sr-Zn-silicate glass developed for sealing solid oxide fuel cells.

  7. Fractal free energy landscapes in structural glasses.

    PubMed

    Charbonneau, Patrick; Kurchan, Jorge; Parisi, Giorgio; Urbani, Pierfrancesco; Zamponi, Francesco

    2014-04-24

    Glasses are amorphous solids whose constituent particles are caged by their neighbours and thus cannot flow. This sluggishness is often ascribed to the free energy landscape containing multiple minima (basins) separated by high barriers. Here we show, using theory and numerical simulation, that the landscape is much rougher than is classically assumed. Deep in the glass, it undergoes a 'roughness transition' to fractal basins, which brings about isostaticity and marginal stability on approaching jamming. Critical exponents for the basin width, the weak force distribution and the spatial spread of quasi-contacts near jamming can be analytically determined. Their value is found to be compatible with numerical observations. This advance incorporates the jamming transition of granular materials into the framework of glass theory. Because temperature and pressure control what features of the landscape are experienced, glass mechanics and transport are expected to reflect the features of the topology we discuss here.

  8. SERS-active silver nanoparticle aggregates produced in high-iron float glass by ion exchange process

    NASA Astrophysics Data System (ADS)

    Karvonen, L.; Chen, Y.; Säynätjoki, A.; Taiviola, K.; Tervonen, A.; Honkanen, S.

    2011-11-01

    Silver nanoparticles were produced in iron containing float glasses by silver-sodium ion exchange and post-annealing. In particular, the effect of the concentration and the oxidation state of iron in the host glass on the nanoparticle formation was studied. After the nanoparticle fabrication process, the samples were characterized by optical absorption measurements. The samples were etched to expose nanoparticle aggregates on the surface, which were studied by optical microscopy and scanning electron microscopy. The SERS-activity of these glass samples was demonstrated and compared using a dye molecule Rhodamine 6G (R6G) as an analyte. The importance of the iron oxidation level for reduction process is discussed. The glass with high concentration of Fe 2+ ions was found to be superior in SERS applications of silver nanoparticles. The optimal surface features in terms of SERS enhancement are also discussed.

  9. Studies of LA-ICP-MS on quartz glasses at different wavelengths of a Nd:YAG laser.

    PubMed

    Becker, J S; Tenzler, D

    2001-07-01

    The capability of LA-ICP-MS for determination of trace impurities in transparent quartz glasses was investigated. Due to low or completely lacking absorption of laser radiation, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) proves difficult on transparent solids, and in particular the quantification of measurement results is problematic in these circumstances. Quartz glass reference materials of various compositions were studied by using a Nd:YAG laser system with focused laser radiation of wavelengths of 1064 nm, 532 nm and 266 nm, and an ICP-QMS (Elan 6000, Perkin Elmer). The influence of ICP and laser ablation conditions in the analysis of quartz glasses of different compositions was investigated, with the laser power density in the region of interaction between laser radiation and solid surface determining the ablation process. The trace element concentration was determined via calibration curves recorded with the aid of quartz glass reference materials. Under optimized measuring conditions the correlation coefficients of the calibration curves are in the range of 0.9-1. The relative sensitivity factors of the trace elements determined in the quartz glass matrix are 0.1-10 for most of the trace elements studied by LA-ICP-MS. The detection limits of the trace elements in quartz glass are in the low ng/g to pg/g range.

  10. [Analysis of productivity, quality and cost of first grade laboratories: blood biometry].

    PubMed

    Avila, L; Hernández, P; Cruz, A; Zurita, B; Terres, A M; Cruz, C

    1999-04-01

    Assessment of productivity, quality and production costs and determination of the efficiency of top grade clinical laboratories in Mexico. Ten laboratories were selected from among the total number (52) existing in Mexico City, and the Donabedian model of structure, process and results were applied. Blood count was selected as a tracer. The principal problems found were: inadequate distribution of trained human resources, poor glass material, inadequate analytic process and low productivity. These factors are reflected in the unit costs, which exceed reference laboratory costs by 200%. Only 50% of the laboratories analyzed generate reliable results. Only 20% of the laboratories studied operate efficiently. To solve the problems identified requires integral strategies at different levels. A specific recomendation for the improvement of quality and productivity is an assessment of the cost/benefit of creating a central laboratory and using the remaining sites exclusively for the collection of samples.

  11. Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

    PubMed Central

    Zarr, Robert R; Heckert, N Alan; Leigh, Stefan D

    2014-01-01

    Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg·m−3 to 180 kg·m−3, and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ,T)=a0+a1ρ+a2T+a3T3+a4e−(T−a5a6)2where λ(ρ,T) is the predicted thermal conductivity (W·m−1·K−1), ρ is the bulk density (kg·m−3), T is the mean temperature (K) and ai (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ,T)=a0+a1ρ+a2T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs. PMID:26601034

  12. Analytical ultrasonics for characterization of metallurgical microstructures and transformations

    NASA Technical Reports Server (NTRS)

    Rosen, M.

    1986-01-01

    The application of contact (piezoelectric) and noncontact (laser generation and detection) ultrasonic techniques for dynamic investigation of precipitation hardening processes in aluminum alloys, as well as crystallization and phase transformation in rapidly solidified amorphous and microcrystalline alloys is discussed. From the variations of the sound velocity and attenuation the precipitation mechanism and kinetics were determined. In addition, a correlation was established between the observed changes in the velocity and attenuation and the mechanical properties of age-hardenable aluminum alloys. The behavior of the elastic moduli, determined ultrasonically, were found to be sensitive to relaxation, crystallization and phase decomposition phenomena in rapidly solidified metallic glasses. Analytical ultrasonics enables determination of the activation energies and growth parameters of the reactions. Therefrom theoretical models can be constructed to explain the changes in mechanical and physical properties upon heat treatment of glassy alloys. The composition dependence of the elastic moduli in amorphous Cu-Zr alloys was found to be related to the glass transition temperature, and consequently to the glass forming ability of these alloys. Dynamic ultrasonic analysis was found to be feasible for on-line, real-time, monitoring of metallurgical processes.

  13. Analytical and experimental study of control effort associated with model reference adaptive control

    NASA Technical Reports Server (NTRS)

    Messer, R. S.; Haftka, R. T.; Cudney, H. H.

    1992-01-01

    Numerical simulation results presently obtained for the performance of model reference adaptive control (MRAC) are experimentally verified, with a view to accounting for differences between the plant and the reference model after the control function has been brought to bear. MRAC is both experimentally and analytically applied to a single-degree-of-freedom system, as well as analytically to a MIMO system having controlled differences between the reference model and the plant. The control effort is noted to be sensitive to differences between the plant and the reference model.

  14. Experimental and Simulative Investigation of Laser Transmission Welding under Consideration of Scattering

    NASA Astrophysics Data System (ADS)

    Devrient, M.; Da, X.; Frick, T.; Schmidt, M.

    Laser transmission welding is a well known joining technology for thermoplastics. Because of the needs of lightweight, cost effective and green production thermoplastics are usually filled with glass fibers. These lead to higher absorption and more scattering within the upper joining partner with a negative influence on the welding process. Here an experimental method for the characterization of the scattering behavior of semi crystalline thermoplastics filled with short glass fibers and a finite element model of the welding process capable to consider scattering as well as an analytical model are introduced. The experimental data is used for the numerical and analytical investigation of laser transmission welding under consideration of scattering. The scattering effects of several thermoplastics onto the calculated temperature fields as well as weld seam geometries are quantified.

  15. Capillary electrophoresis with indirect UV detection for the determination of stabilizers and citrates present in human albumin solutions.

    PubMed

    Jaworska, Małgorzata; Cygan, Paulina; Wilk, Małgorzata; Anuszewska, Elzbieta

    2009-08-15

    Sodium caprylate and N-acetyltryptophan are the most frequently used stabilizers that protect the albumin from aggregation or heat induced denaturation. In turn citrates - excipients remaining after fractionation process - can be treated as by-product favoring leaching aluminum out of glass containers whilst albumin solution is stored. With ionic nature these substances have all the markings of a subject for capillary electrophoresis analysis. Thus CE methods were proposed as new approach for quality control of human albumin solution in terms of determination of stabilizers and citrates residue. Human albumin solutions both 5% and 20% from various manufacturers were tested. Indirect detection mode was set to provide sufficient detectability of analytes lacking of chromophores. As being anions analytes were separated with reversed electroosmotic flow. As a result of method optimization two background electrolytes based on p-hydroxybenzoic acid and 2,6-pyridinedicarboxylic acid were selected for stabilizers and citrates separation, respectively. The optimized methods were successfully validated. For citrates that require quantification below 100microM the method demonstrated the precision less than 4% and the limit of detection at 4microM. In order to check the new methods accuracy and applicability the samples were additionally tested with selected reference methods. The proposed methods allow reliable quantification of stabilizers and citrates in human albumin solution that was confirmed by method validation as well as result comparison with reference methods. The CE methods are considered to be suitable for quality control yet simplifying and reducing cost of analysis.

  16. Characterization of low concentration uranium glass working materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppich, G. R.; Wimpenny, J. B.; Leever, M. E.

    A series of uranium-doped silicate glasses were created at (Lawrence Livermore National Laboratory) LLNL, to be used as working reference material analogs for low uranium concentration research. Specifically, the aim of this effort was the generation of well-characterized glasses spanning a range of concentrations and compositions, and of sufficient homogeneity in uranium concentration and isotopic composition, for instrumentation research and development purposes. While the glasses produced here are not intended to replace or become standard materials for uranium concentration or uranium isotopic composition, it is hoped that they will help fill a current gap, providing low-level uranium glasses sufficient formore » methods development and method comparisons within the limitations of the produced glass suite. Glasses are available for research use by request.« less

  17. Spectral multivariate calibration without laboratory prepared or determined reference analyte values.

    PubMed

    Ottaway, Josh; Farrell, Jeremy A; Kalivas, John H

    2013-02-05

    An essential part to calibration is establishing the analyte calibration reference samples. These samples must characterize the sample matrix and measurement conditions (chemical, physical, instrumental, and environmental) of any sample to be predicted. Calibration usually requires measuring spectra for numerous reference samples in addition to determining the corresponding analyte reference values. Both tasks are typically time-consuming and costly. This paper reports on a method named pure component Tikhonov regularization (PCTR) that does not require laboratory prepared or determined reference values. Instead, an analyte pure component spectrum is used in conjunction with nonanalyte spectra for calibration. Nonanalyte spectra can be from different sources including pure component interference samples, blanks, and constant analyte samples. The approach is also applicable to calibration maintenance when the analyte pure component spectrum is measured in one set of conditions and nonanalyte spectra are measured in new conditions. The PCTR method balances the trade-offs between calibration model shrinkage and the degree of orthogonality to the nonanalyte content (model direction) in order to obtain accurate predictions. Using visible and near-infrared (NIR) spectral data sets, the PCTR results are comparable to those obtained using ridge regression (RR) with reference calibration sets. The flexibility of PCTR also allows including reference samples if such samples are available.

  18. Silicon isotope ratio measurements by inductively coupled plasma tandem mass spectrometry for alteration studies of nuclear waste glasses.

    PubMed

    Gourgiotis, Alkiviadis; Ducasse, Thomas; Barker, Evelyne; Jollivet, Patrick; Gin, Stéphane; Bassot, Sylvain; Cazala, Charlotte

    2017-02-15

    High-level, long-lived nuclear waste arising from spent fuel reprocessing is vitrified in silicate glasses for final disposal in deep geologic formations. In order to better understand the mechanisms driving glass dissolution, glass alteration studies, based on silicon isotope ratio monitoring of 29 Si-doped aqueous solutions, were carried out in laboratories. This work explores the capabilities of the new type of quadrupole-based ICP-MS, the Agilent 8800 tandem quadrupole ICP-MS/MS, for accurate silicon isotope ratio determination for alteration studies of nuclear waste glasses. In order to avoid silicon polyatomic interferences, a new analytical method was developed using O 2 as the reaction gas in the Octopole Reaction System (ORS), and silicon isotopes were measured in mass-shift mode. A careful analysis of the potential polyatomic interferences on SiO + and SiO 2 + ion species was performed, and we found that SiO + ion species suffer from important polyatomic interferences coming from the matrix of sample and standard solutions (0.5M HNO 3 ). For SiO 2 + , no interferences were detected, and thus, these ion species were chosen for silicon isotope ratio determination. A number of key settings for accurate isotope ratio analysis like, detector dead time, integration time, number of sweeps, wait time offset, memory blank and instrumental mass fractionation, were considered and optimized. Particular attention was paid to the optimization of abundance sensitivity of the quadrupole mass filter before the ORS. We showed that poor abundance sensitivity leads to a significant shift of the data away from the Exponential Mass Fractionation Law (EMFL) due to the spectral overlaps of silicon isotopes combined with different oxygen isotopes (i.e. 28 Si 16 O 18 O + , 30 Si 16 O 16 O + ). The developed method was validated by measuring a series of reference solutions with different 29 Si enrichment. Isotope ratio trueness, uncertainty and repeatability were found to be <0.2%, <0.5% and <0.6%, respectively. These performances meet the requirements of the studies of nuclear glasses alteration and open up possibilities to use this method for precise determination of silicon content in natural samples by Isotope Dilution. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples distributed in March 1999

    USGS Publications Warehouse

    Farrar, Jerry W.; Chleboun, Kimberly M.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  20. Theoretical study of production of unique glasses in space. [kinetic relationships describing nucleation and crystallization phenomena

    NASA Technical Reports Server (NTRS)

    Larsen, D. C.; Sievert, J. L.

    1975-01-01

    The potential of producing the glassy form of selected materials in the weightless, containerless nature of space processing is examined through the development of kinetic relationships describing nucleation and crystallization phenomena. Transformation kinetics are applied to a well-characterized system (SiO2), an excellent glass former (B2O3), and a poor glass former (Al2O3) by conventional earth processing methods. Viscosity and entropy of fusion are shown to be the primary materials parameters controlling the glass forming tendency. For multicomponent systems diffusion-controlled kinetics and heterogeneous nucleation effects are considered. An analytical empirical approach is used to analyze the mullite system. Results are consistent with experimentally observed data and indicate the promise of mullite as a future space processing candidate.

  1. Thermo-Osmotic Flow in Thin Films.

    PubMed

    Bregulla, Andreas P; Würger, Alois; Günther, Katrin; Mertig, Michael; Cichos, Frank

    2016-05-06

    We report on the first microscale observation of the velocity field imposed by a nonuniform heat content along the solid-liquid boundary. We determine both radial and vertical velocity components of this thermo-osmotic flow field by tracking single tracer nanoparticles. The measured flow profiles are compared to an approximate analytical theory and to numerical calculations. From the measured slip velocity we deduce the thermo-osmotic coefficient for both bare glass and Pluronic F-127 covered surfaces. The value for Pluronic F-127 agrees well with Soret data for polyethylene glycol, whereas that for glass differs from literature values and indicates the complex boundary layer thermodynamics of glass-water interfaces.

  2. Elemental analysis of glass by laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES).

    PubMed

    Schenk, Emily R; Almirall, José R

    2012-04-10

    The elemental analysis of glass evidence has been established as a powerful discrimination tool for forensic analysts. Laser ablation inductively coupled plasma optical emission spectrometry (LA-ICP-OES) has been compared to laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and energy dispersive micro X-ray fluorescence spectroscopy (μXRF/EDS) as competing instrumentation for the elemental analysis of glass. The development of a method for the forensic analysis of glass coupling laser ablation to ICP-OES is presented for the first time. LA-ICP-OES has demonstrated comparable analytical performance to LA-ICP-MS based on the use of the element menu, Al (Al I 396.15 nm), Ba (Ba II 455.40 nm), Ca (Ca II 315.88 nm), Fe (Fe II 238.20 nm), Li (Li I 670.78 nm), Mg (Mg I 285.21 nm), Sr (Sr II 407.77 nm), Ti (Ti II 368.51 nm), and Zr (Zr II 343.82 nm). The relevant figures of merit, such as precision, accuracy and sensitivity, are presented and compared to LA-ICP-MS. A set of 41 glass samples was used to assess the discrimination power of the LA-ICP-OES method in comparison to other elemental analysis techniques. This sample set consisted of several vehicle glass samples that originated from the same source (inside and outside windshield panes) and several glass samples that originated from different vehicles. Different match criteria were used and compared to determine the potential for Type I and Type II errors. It was determined that broader match criteria is more applicable to the forensic comparison of glass analysis because it can reduce the affect that micro-heterogeneity inherent in the glass fragments and a less than ideal sampling strategy can have on the interpretation of the results. Based on the test set reported here, a plus or minus four standard deviation (± 4s) match criterion yielded the lowest possibility of Type I and Type II errors. The developed LA-ICP-OES method has been shown to perform similarly to LA-ICP-MS in the discrimination among different sources of glass while offering the advantages of a lower cost of acquisition and operation of analytical instrumentation making ICP-OES a possible alternative elemental analysis method for the forensic laboratory. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Investigation of hydrophobic substrates for solution residue analysis utilizing an ambient desorption liquid sampling-atmospheric pressure glow discharge microplasma.

    PubMed

    Paing, Htoo W; Marcus, R Kenneth

    2018-03-12

    A practical method for preparation of solution residue samples for analysis utilizing the ambient desorption liquid sampling-atmospheric pressure glow discharge optical emission spectroscopy (AD-LS-APGD-OES) microplasma is described. Initial efforts involving placement of solution aliquots in wells drilled into copper substrates, proved unsuccessful. A design-of-experiment (DOE) approach was carried out to determine influential factors during sample deposition including solution volume, solute concentration, number of droplets deposited, and the solution matrix. These various aspects are manifested in the mass of analyte deposited as well as the size/shape of the product residue. Statistical analysis demonstrated that only those initial attributes were significant factors towards the emission response of the analyte. Various approaches were investigated to better control the location/uniformity of the deposited sample. Three alternative substrates, a glass slide, a poly(tetrafluoro)ethylene (PTFE) sheet, and a polydimethylsiloxane (PDMS)-coated glass slide, were evaluated towards the microplasma analytical performance. Co-deposition with simple organic dyes provided an accurate means of determining the location of the analyte with only minor influence on emission responses. The PDMS-coated glass provided the best performance by virtue of its providing a uniform spatial distribution of the residue material. This uniformity yielded an improved limits of detection by approximately 22× for 20 μL and 4 x for 2 μL over the other two substrates. While they operate by fundamentally different processes, this choice of substrate is not restricted to the LS-APGD, but may also be applicable to other AD methods such as DESI, DART, or LIBS. Further developments will be directed towards a field-deployable ambient desorption OES source for quantitative analysis of microvolume solution residues of nuclear forensics importance.

  4. IR Li2Ga2GeS6 nanocrystallized GeS2-Ga2S3-Li2S electroconductive chalcogenide glass with good nonlinearity

    PubMed Central

    Liu, Qiming; Zhang, Peng

    2014-01-01

    GeS2-Ga2S3-Li2S electroconductive glasses were prepared by the conventional melt-quenching method through carefully controlling the heating rate. Comparing with the reference of glass-forming region, our investigated GeS2-Ga2S3-Li2S system was extended to the cation ratio of 0–20% Li with around 40% Ga. GeS2-Ga2S3-Li2S glass-ceramics containing IR Li2Ga2GeS6 nonlinear nanocrystals were obtained by the more carefully controlled heating rate. Its optical nonlinearity was investigated by the Maker fringe measurements, the maximum second harmonic intensity was observed to be 0.35 of the reference Z-cut quartz. IR Li2Ga2GeS6 nonlinear crystals were directly obtained at the composition of 40GeS2-30GaS1.5-30LiS0.5. PMID:25030713

  5. Incorporation de particules de verre post-consommation dans un enrobe bitumineux de type ESG14

    NASA Astrophysics Data System (ADS)

    Lachance Tremblay, Eric

    In 2008, around 244,000 tons of glass was produced by the Quebec population. From this number, 128,000 tons were collected by various means of collection. Glass recycling is problematic because all the glass that cannot be classified according to the type can't be used to manufacture new products. It is therefore necessary to find new sources of uses for this material. Because the use of recycled materials in road structure material is beneficial from an environmental and sometimes structural point of view, the idea of using recycled glass into asphalt mixture was recently studied at the LCMB. Nowadays, the use of recycled glass in asphalt mixture is not regulated by the MTQ. This research goal was to verify the possibility of using recycled glass particles in a ESG14 asphalt mixture while maintaining equivalent properties and performance compared to a conventional mix. Different dosages of recycled glass particles have been studied to evaluate the effect of glass on the asphalt mixture volumetric characteristics, the ability of compaction and the rutting resistance. These mixes were formulated according to the LC formulation of the MTQ. The first part allowed selecting an optimal dosage of recycled glass particles. Thereafter, the thermo mechanical performance (resistance to low temperatures (TSRST), complex modulus (E*) and resistance to fatigue cracking), physical characteristics (macro texture and surface grip) and durability (resistance to water damage) of the asphalt mixture with the optimal dosage were evaluated and compared with a reference mixture. The results show that the ESG14 mixture with recycled glass formulated with the LC method is more susceptible to rutting than the reference mixture. Therefore, a reduction of the bitumen content can increase the rutting resistance while conserving equivalent properties to a conventional mix regarding resistance to low temperatures, complex modulus, resistance to fatigue cracking as well as the physical characteristics. Therefore, the use of recycled in glass seems to modify the asphalt behavior and increase the moisture susceptibility.

  6. Speckle in the diffraction patterns of Hendricks-Teller and icosahedral glass models

    NASA Technical Reports Server (NTRS)

    Garg, Anupam; Levine, Dov

    1988-01-01

    It is shown that the X-ray diffraction patterns from the Hendricks-Teller model for layered systems and the icosahedral glass models for the icosahedral phases show large fluctuations between nearby scattering wave vectors and from sample to sample, that are quite analogous to laser speckle. The statistics of these fluctuations are studied analytically for the first model and via computer simulations for the second. The observability of these effects is discussed briefly.

  7. A Randomized Study Comparing Digital Imaging to Traditional Glass Slide Microscopy for Breast Biopsy and Cancer Diagnosis

    PubMed Central

    Elmore, Joann G.; Longton, Gary M.; Pepe, Margaret S.; Carney, Patricia A.; Nelson, Heidi D.; Allison, Kimberly H.; Geller, Berta M.; Onega, Tracy; Tosteson, Anna N. A.; Mercan, Ezgi; Shapiro, Linda G.; Brunyé, Tad T.; Morgan, Thomas R.; Weaver, Donald L.

    2017-01-01

    Background: Digital whole slide imaging may be useful for obtaining second opinions and is used in many countries. However, the U.S. Food and Drug Administration requires verification studies. Methods: Pathologists were randomized to interpret one of four sets of breast biopsy cases during two phases, separated by ≥9 months, using glass slides or digital format (sixty cases per set, one slide per case, n = 240 cases). Accuracy was assessed by comparing interpretations to a consensus reference standard. Intraobserver reproducibility was assessed by comparing the agreement of interpretations on the same cases between two phases. Estimated probabilities of confirmation by a reference panel (i.e., predictive values) were obtained by incorporating data on the population prevalence of diagnoses. Results: Sixty-five percent of responding pathologists were eligible, and 252 consented to randomization; 208 completed Phase I (115 glass, 93 digital); and 172 completed Phase II (86 glass, 86 digital). Accuracy was slightly higher using glass compared to digital format and varied by category: invasive carcinoma, 96% versus 93% (P = 0.04); ductal carcinoma in situ (DCIS), 84% versus 79% (P < 0.01); atypia, 48% versus 43% (P = 0.08); and benign without atypia, 87% versus 82% (P < 0.01). There was a small decrease in intraobserver agreement when the format changed compared to when glass slides were used in both phases (P = 0.08). Predictive values for confirmation by a reference panel using glass versus digital were: invasive carcinoma, 98% and 97% (not significant [NS]); DCIS, 70% and 57% (P = 0.007); atypia, 38% and 28% (P = 0.002); and benign without atypia, 97% and 96% (NS). Conclusions: In this large randomized study, digital format interpretations were similar to glass slide interpretations of benign and invasive cancer cases. However, cases in the middle of the spectrum, where more inherent variability exists, may be more problematic in digital format. Future studies evaluating the effect these findings exert on clinical practice and patient outcomes are required. PMID:28382226

  8. Plutonium immobilization in glass and ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knecht, D.A.; Murphy, W.M.

    1996-05-01

    The Materials Research Society Nineteenth Annual Symposium on the Scientific Basis for Nuclear Waste Management was held in Boston on November 27 to December 1, 1995. Over 150 papers were presented at the Symposium dealing with all aspects of nuclear waste management and disposal. Fourteen oral sessions and on poster session included a Plenary session on surplus plutonium dispositioning and waste forms. The proceedings, to be published in April, 1996, will provide a highly respected, referred compilation of the state of scientific development in the field of nuclear waste management. This paper provides a brief overview of the selected Symposiummore » papers that are applicable to plutonium immobilization and plutonium waste form performance. Waste forms that were described at the Symposium cover most of the candidate Pu immobilization options under consideration, including borosilicate glass with a melting temperature of 1150 {degrees}C, a higher temperature (1450 {degrees}C) lanthanide glass, single phase ceramics, multi-phase ceramics, and multi-phase crystal-glass composites (glass-ceramics or slags). These Symposium papers selected for this overview provide the current status of the technology in these areas and give references to the relevant literature.« less

  9. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    PubMed

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  10. The surface pH of glass ionomer cavity lining agents.

    PubMed

    Woolford, M J

    1989-12-01

    It is considered that acid release from the surface of glass ionomer (polyalkenoate) cements may be associated with early pulpal sensitivity following the use of these materials. This study was carried out to examine the surface pH of different types of glass ionomer lining cements using a flat-ended pH electrode. It was found that the surface pH remains low for this group of materials during the first hour of setting. Different types of glass ionomer lining cement were also shown to behave differently when considering acid release from the surface. Conclusions regarding the behaviour of glass ionomers should only be made with reference to the specific material tested.

  11. Diversity, culture and the glass ceiling.

    PubMed

    Wilson, Eleanor

    2014-01-01

    A reference to the term, the glass ceiling, has come to embody more than gender equality among women and men. Today the term embraces the quest of all minorities and their journey towards equality in the workplace. The purpose of this article is to bring attention to the subject of diversity, culture, and the glass ceiling. The article will discuss the history of the glass ceiling and how its broadened meaning is relevant in today's workplace. It will also provide statistics showing how diversity and culture are lacking among the top echelon of today's executives, the barriers faced by minorities as they journey towards executive leadership, and how to overcome these barriers to truly shatter the glass ceiling.

  12. Ground-state magnetization of the Ising spin glass: A recursive numerical method and Chen-Ma scaling

    NASA Astrophysics Data System (ADS)

    Sepehrinia, Reza; Chalangari, Fartash

    2018-03-01

    The ground-state properties of quasi-one-dimensional (Q1D) Ising spin glass are investigated using an exact numerical approach and analytical arguments. A set of coupled recursive equations for the ground-state energy are introduced and solved numerically. For various types of coupling distribution, we obtain accurate results for magnetization, particularly in the presence of a weak external magnetic field. We show that in the weak magnetic field limit, similar to the 1D model, magnetization exhibits a singular power-law behavior with divergent susceptibility. Remarkably, the spectrum of magnetic exponents is markedly different from that of the 1D system even in the case of two coupled chains. The magnetic exponent makes a crossover from being dependent on a distribution function to a constant value independent of distribution. We provide an analytic theory for these observations by extending the Chen-Ma argument to the Q1D case. We derive an analytical formula for the exponent which is in perfect agreement with the numerical results.

  13. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples: T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents) and Hg-27 (Mercury) distributed in September 1998

    USGS Publications Warehouse

    Farrar, Jerry W.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples -- T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents), and Hg- 27 (mercury) -- which were distributed in September 1998 to 162 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  14. Ocean foam generation and modeling

    NASA Technical Reports Server (NTRS)

    Porter, R. A.; Bechis, K. P.

    1976-01-01

    A laboratory investigation was conducted to determine the physical and microwave properties of ocean foam. Special foam generators were designed and fabricated, using porous glass sheets, known as glass frits, as the principal element. The glass frit was sealed into a water-tight vertical box, a few centimeters from the bottom. Compressed air, applied to the lower chamber, created ocean foam from sea water lying on the frit. Foam heights of 30 cm were readily achieved, with relatively low air pressures. Special photographic techniques and analytical procedures were employed to determine foam bubble size distributions. In addition, the percentage water content of ocean foam was determined with the aid of a particulate sampling procedure. A glass frit foam generator, with pore diameters in the range 70 - 100 micrometers, produced foam with bubble distributions very similar to those found on the surface of natural ocean foam patches.

  15. Reference commercial high-level waste glass and canister definition

    NASA Astrophysics Data System (ADS)

    Slate, S. C.; Ross, W. A.; Partain, W. L.

    1981-09-01

    Technical data and performance characteristics of a high level waste glass and canister intended for use in the design of a complete waste encapsulation package suitable for disposal in a geologic repository are presented. The borosilicate glass contained in the stainless steel canister represents the probable type of high level waste product that is produced in a commercial nuclear-fuel reprocessing plant. Development history is summarized for high level liquid waste compositions, waste glass composition and characteristics, and canister design. The decay histories of the fission products and actinides (plus daughters) calculated by the ORIGEN-II code are presented.

  16. Glass Ceiling for Women in Higher Education.

    ERIC Educational Resources Information Center

    Schedler, Petra; Glastra, Folke; Hake, Barry

    2003-01-01

    Discusses the place of women in higher education in the Netherlands. Suggests that it is not a question of numbers but of orientation, field, and the glass ceiling. Asserts that despite some improvement, higher education may be one of the last bastions against the recognition of women's worth. (Contains 42 references.) (JOW)

  17. Report on the U.S. Geological Survey's Evaluation Program Standard Reference Samples Distributed in October 1995: T-137 (Trace Constituents), M-136 (Major Constituents), N-47 (Nutrient Constituents), N-48 (Nutrient Constituents), P-25 (Low Ionic Strength Constituents), and Hg-21 (Mercury)

    USGS Publications Warehouse

    Farrar, Jerry W.; Long, H. Keith

    1996-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  18. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1994; T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), and Hg-18 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  19. Report of the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1993; T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents, N-38 (nutrients), N-39 (nutrients), P-20 (low ionic strength, and Hg-16 (mercury)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1993-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  20. Influence of dust and mud on the optical, chemical, and mechanical properties of a pv protective glass

    NASA Astrophysics Data System (ADS)

    Yilbas, Bekir Sami.; Ali, Haider; Khaled, Mazen M.; Al-Aqeeli, Nasser; Abu-Dheir, Numan; Varanasi, Kripa K.

    2015-10-01

    Recent developments in climate change have increased the frequency of dust storms in the Middle East. Dust storms significantly influence the performances of solar energy harvesting systems, particularly (photovoltaic) PV systems. The characteristics of the dust and the mud formed from this dust are examined using various analytical tools, including optical, scanning electron, and atomic force microscopies, X-ray diffraction, energy spectroscopy, and Fourier transform infrared spectroscopy. The adhesion, cohesion and frictional forces present during the removal of dry mud from the glass surface are determined using a microtribometer. Alkali and alkaline earth metal compounds in the dust dissolve in water to form a chemically active solution at the glass surface. This solution modifies the texture of the glass surface, thereby increasing the microhardness and decreasing the transmittance of the incident optical radiation. The force required to remove the dry mud from the glass surface is high due to the cohesive forces that result from the dried mud solution at the interface between the mud and the glass. The ability altering the characteristics of the glass surface could address the dust/mud-related limitations of protective surfaces and has implications for efficiency enhancements in solar energy systems.

  1. Influence of dust and mud on the optical, chemical, and mechanical properties of a pv protective glass.

    PubMed

    Yilbas, Bekir Sami; Ali, Haider; Khaled, Mazen M; Al-Aqeeli, Nasser; Abu-Dheir, Numan; Varanasi, Kripa K

    2015-10-30

    Recent developments in climate change have increased the frequency of dust storms in the Middle East. Dust storms significantly influence the performances of solar energy harvesting systems, particularly (photovoltaic) PV systems. The characteristics of the dust and the mud formed from this dust are examined using various analytical tools, including optical, scanning electron, and atomic force microscopies, X-ray diffraction, energy spectroscopy, and Fourier transform infrared spectroscopy. The adhesion, cohesion and frictional forces present during the removal of dry mud from the glass surface are determined using a microtribometer. Alkali and alkaline earth metal compounds in the dust dissolve in water to form a chemically active solution at the glass surface. This solution modifies the texture of the glass surface, thereby increasing the microhardness and decreasing the transmittance of the incident optical radiation. The force required to remove the dry mud from the glass surface is high due to the cohesive forces that result from the dried mud solution at the interface between the mud and the glass. The ability altering the characteristics of the glass surface could address the dust/mud-related limitations of protective surfaces and has implications for efficiency enhancements in solar energy systems.

  2. Representative of America: Creating Inclusion in the Senior Executive Service

    DTIC Science & Technology

    2012-02-27

    to reach the upper echelons of organizations in America. According to a 1995 study commissioned by the Federal Glass Ceiling Commission, “97% of the...There is a direct correlation between the similarity/attraction theory and the Glass Ceiling and barriers in DoD that may be a Purple Ceiling (senior...managers who are former military officers).17 The Glass Ceiling refers to obstacles that often confront ethnic groups and females as they attempt

  3. Electron irradiation induced phase separation in a sodium borosilicate glass

    NASA Astrophysics Data System (ADS)

    Sun, K.; Wang, L. M.; Ewing, R. C.; Weber, W. J.

    2004-06-01

    Electron irradiation induced phase separation in a sodium borosilicate glass was studied in situ by analytical electron microscopy. Distinctly separate phases that are rich in boron and silicon formed at electron doses higher than 4.0 × 10 11 Gy during irradiation. The separated phases are still in amorphous states even at a much high dose (2.1 × 10 12 Gy). It indicates that most silicon atoms remain tetrahedrally coordinated in the glass during the entire irradiation period, except some possible reduction to amorphous silicon. The particulate B-rich phase that formed at high dose was identified as amorphous boron that may contain some oxygen. Both ballistic and ionization processes may contribute to the phase separation.

  4. Nonlinear characterization of silver nanocrystals incorporated tellurite glasses for fiber development

    NASA Astrophysics Data System (ADS)

    Zhou, Zhiguang; Tan, Wenjiang; Si, Jinhai; Zhan, Huan; He, Jianli; Lin, Aoxiang

    2011-12-01

    To develop high nonlinear optical fibers for all-optical switching applications, 7.5 wt% AgNO3 was incorporated into tellurite glasses with composition of 75TeO2-20ZnO-5Na2CO3 (TZN75) under precisely-controlled experimental conditions to form 7.5Ag-TZN75 glass. Surface Plasmon resonance absorption peak of Ag nanocrystals embedded in 7.5Ag-TZN75 glass was found to center at 552 nm. By degenerated four-wave mixing method, the non-resonant nonlinear refractive index, n2, of 7.5Ag-TZN75 glass was measured to be 7.54×10-19 m2•W-1 at 1500 nm, about 3 times of the reference TZN75 glass without any dopant and 27 times of the silicate glasses and fibers, and the response time is about 1 picosecond.

  5. Durability Characteristics Analysis of Plastic Worm Wheel with Glass Fiber Reinforced Polyamide.

    PubMed

    Kim, Gun-Hee; Lee, Jeong-Won; Seo, Tae-Il

    2013-05-10

    Plastic worm wheel is widely used in the vehicle manufacturing field because it is favorable for weight lightening, vibration and noise reduction, as well as corrosion resistance. However, it is very difficult for general plastics to secure the mechanical properties that are required for vehicle gears. If the plastic resin is reinforced by glass fiber in the fabrication process of plastic worm wheel, it is possible to achieve the mechanical properties of metallic material levels. In this study, the mechanical characteristic analysis of the glass-reinforced plastic worm wheel, according to the contents of glass fiber, is performed by analytic and experimental methods. In the case of the glass fiber-reinforced resin, the orientation and contents of glass fibers can influence the mechanical properties. For the characteristic prediction of plastic worm wheel, computer-aided engineering (CAE) analysis processes such as structural and injection molding analysis were executed with the polyamide resin reinforcement glass fiber (25 wt %, 50 wt %). The injection mold for fabricating the prototype plastic worm wheel was designed and made to reflect the CAE analysis results. Finally, the durability of prototype plastic worm wheel fabricated by the injection molding process was evaluated by the experimental method and the characteristics according to the glass fiber contents.

  6. Durability Characteristics Analysis of Plastic Worm Wheel with Glass Fiber Reinforced Polyamide

    PubMed Central

    Kim, Gun-Hee; Lee, Jeong-Won; Seo, Tae-Il

    2013-01-01

    Plastic worm wheel is widely used in the vehicle manufacturing field because it is favorable for weight lightening, vibration and noise reduction, as well as corrosion resistance. However, it is very difficult for general plastics to secure the mechanical properties that are required for vehicle gears. If the plastic resin is reinforced by glass fiber in the fabrication process of plastic worm wheel, it is possible to achieve the mechanical properties of metallic material levels. In this study, the mechanical characteristic analysis of the glass-reinforced plastic worm wheel, according to the contents of glass fiber, is performed by analytic and experimental methods. In the case of the glass fiber-reinforced resin, the orientation and contents of glass fibers can influence the mechanical properties. For the characteristic prediction of plastic worm wheel, computer-aided engineering (CAE) analysis processes such as structural and injection molding analysis were executed with the polyamide resin reinforcement glass fiber (25 wt %, 50 wt %). The injection mold for fabricating the prototype plastic worm wheel was designed and made to reflect the CAE analysis results. Finally, the durability of prototype plastic worm wheel fabricated by the injection molding process was evaluated by the experimental method and the characteristics according to the glass fiber contents. PMID:28809248

  7. Reference-point-independent dynamics of molecular liquids and glasses in the tensorial formalism

    NASA Astrophysics Data System (ADS)

    Schilling, Rolf

    2002-05-01

    We apply the tensorial formalism to the dynamics of molecular liquids and glasses. This formalism separates the degrees of freedom into translational and orientational ones. Using the Mori-Zwanzig projection formalism, the equations of motion for the tensorial density correlators Slmn,l'm'n'(q-->,t) are derived. For this we show how to choose the slow variables such that the resulting Mori-Zwanzig equations are covariant under a change of the reference point of the body fixed frame. We also prove that the memory kernels obtained from mode-coupling theory (MCT) including all approximations preserve the covariance. This covariance makes, e.g., the glass transition point, the two universal scaling laws and particularly the corresponding exponents independent on the reference point and on the mass and moments of inertia, i.e., they only depend on the properties of the potential energy landscape. Finally, we show that the corresponding MCT questions for linear molecules can be obtained from those for arbitrary molecules and that they differ from earlier equations that are not covariant.

  8. Raman Spectrometry.

    ERIC Educational Resources Information Center

    Gardiner, Derek J.

    1980-01-01

    Reviews mainly quantitative analytical applications in the field of Raman spectrometry. Includes references to other reviews, new and analytically untested techniques, and novel sampling and instrument designs. Cites 184 references. (CS)

  9. Micro-PIXE analysis of silicate reference standards

    USGS Publications Warehouse

    Czamanske, G.K.; Sisson, T.W.; Campbell, J.L.; Teesdale, W.J.

    1993-01-01

    The accuracy and precision of the University of Guelph proton microprobe have been evaluated through trace-element analysis of well-characterized silicate glasses and minerals, including BHVO-1 glass, Kakanui augite and hornblende, and ten other natural samples of volcanic glass, amphibole, pyroxene, and garnet. Using the 2.39 wt% Mo in a NIST steel as the standard, excellent precision and agreement between reported and analyzed abundances were obtained for Fe, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, and Nb. -from Authors

  10. A Constructive Approach to Regularity of Lagrangian Trajectories for Incompressible Euler Flow in a Bounded Domain

    NASA Astrophysics Data System (ADS)

    Besse, Nicolas; Frisch, Uriel

    2017-04-01

    The 3D incompressible Euler equations are an important research topic in the mathematical study of fluid dynamics. Not only is the global regularity for smooth initial data an open issue, but the behaviour may also depend on the presence or absence of boundaries. For a good understanding, it is crucial to carry out, besides mathematical studies, high-accuracy and well-resolved numerical exploration. Such studies can be very demanding in computational resources, but recently it has been shown that very substantial gains can be achieved first, by using Cauchy's Lagrangian formulation of the Euler equations and second, by taking advantage of analyticity results of the Lagrangian trajectories for flows whose initial vorticity is Hölder-continuous. The latter has been known for about 20 years (Serfati in J Math Pures Appl 74:95-104, 1995), but the combination of the two, which makes use of recursion relations among time-Taylor coefficients to obtain constructively the time-Taylor series of the Lagrangian map, has been achieved only recently (Frisch and Zheligovsky in Commun Math Phys 326:499-505, 2014; Podvigina et al. in J Comput Phys 306:320-342, 2016 and references therein). Here we extend this methodology to incompressible Euler flow in an impermeable bounded domain whose boundary may be either analytic or have a regularity between indefinite differentiability and analyticity. Non-constructive regularity results for these cases have already been obtained by Glass et al. (Ann Sci Éc Norm Sup 45:1-51, 2012). Using the invariance of the boundary under the Lagrangian flow, we establish novel recursion relations that include contributions from the boundary. This leads to a constructive proof of time-analyticity of the Lagrangian trajectories with analytic boundaries, which can then be used subsequently for the design of a very high-order Cauchy-Lagrangian method.

  11. Manganese recycling in the United States in 1998

    USGS Publications Warehouse

    Jones, Thomas S.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  12. Managers' Beliefs about the Glass Ceiling: Interpersonal and Organizational Factors

    ERIC Educational Resources Information Center

    Elacqua, Tina C.; Beehr, Terry A.; Hansen, Curtiss P.; Webster, Jennica

    2009-01-01

    The glass ceiling refers to the difficulty of women trying to be promoted into the top management levels. The present study examined managers' potential explanations, implicit or explicit, for why women rarely reach the top hierarchical levels in their own organization. Among 685 managers at a large Midwestern insurance company, a model was…

  13. Fabrication and characterization of high impact hybrid matrix composites from thermoset resin and dyneema-glass fabric reinforcement

    NASA Astrophysics Data System (ADS)

    Patel, R. H.; Sharma, S.; Pansuriya, T.; Malgani, E. V.; Sevkani, V.

    2018-05-01

    Hybrid composites have been fabricated by hand lay-up technique with epoxy resin and diethylene tri amine as a hardener for high impact energy absorption with sandwich stacking of different reinforcements of dyneema and glass fabric. High impact grade composites are nowadays gaining a lot of importance in the field of high mechanical load bearing applications, ballistics and bulletproofing. The present work emphases on the fabrication and mechanical properties of the hybrid composites of cut resistant dyneema fabric along with glass fabric reinforced in the thermosetting resin. i.e. epoxy. The prime importance while fabricating such materials have been given to the processing along with selection of the raw materials. High impact resistive materials with low density and henceforth low weight have been manufactured and characterized by IZOD impact tester, UTM, Archimedes density meter and SEM. Throughout the work, satisfactory results have been obtained. Impact resistance was observed to be boosted three times as that of the reference sample of glass fabric and epoxy. The density of the hybrid composite is observed to be 25% as that of the reference sample.

  14. Characterization and optimization of a new high-average power laser glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bayramian, A.

    A new High-Average Power laser glass with favorable thermal-mechanical properties was recently developed by Schott Glass Technologies. We refer to this glass as APG-2, although it does not have an official designation. Fracture studies were conducted which verified the thermomechanical utility of the glass. Consequently, the glass was a promising candidate for a variety of applications such as a Kerr-lens mode-locked short-pulse laser. As a result, cavity designs and optical parameters were calculated to test this hypothesis, and characterization of the lasing properties began. The glass was lased for the first time, and laser slope efficiencies were measured at variousmore » output couplings. Laser efficiencies were observed to drop radically when the pump light duty cycle was increased from 10% to unity. When the new laser glass was compared to commercially available laser glasses LG-750 and APG-1, something appeared to be inhibiting smooth laser action. Further investigations indicated that the thermal lens in the new glass was much larger than in the other glasses making the laser resonator unstable. This thermal lens was then modeled and quantified in a separate experiment.« less

  15. Allanite age-dating: Non-matrix-matched standardization in quadrupole LA-ICP-MS

    NASA Astrophysics Data System (ADS)

    Burn, M.; Lanari, P.; Pettke, T.; Engi, M.

    2014-12-01

    Allanite Th-U-Pb age-dating has recently been found to be powerful in unraveling the timing of geological processes such as the metamorphic dynamics in subduction zones and crystallization velocity of magmas. However, inconsistencies among analytical techniques have raised doubts about the accuracy of allanite age data. Spot analysis techniques such as LA-ICP-MS are claimed to be crucially dependent on matrix-matched standards, the quality of which is variable. We present a new approach in LA-ICP-MS data reduction that allows non-matrix-matched standardization via well constrained zircon reference materials as primary standards. Our data were obtained using a GeoLas Pro 193 nm ArF excimer laser ablation system coupled to an ELAN DRC-e quadrupole ICP-MS. We use 32 μm and 24 μm spot sizes; laser operating conditions of 9 Hz repetition rate and 2.5 J/cm2 fluence have proven advantageous. Matrix dependent downhole fractionation evolution is empirically determined by analyzing 208Pb/232Th and 206Pb/238U and applied prior to standardization. The new data reduction technique was tested on three magmatic allanite reference materials (SISSb, CAPb, TARA); within error these show the same downhole fractionation evolution for all allanite types and in different analytical sessions, provided measurement conditions remain the same. Although the downhole evolution of allanite and zircon differs significantly, a link between zircon and allanite matrix is established by assuming CAPb and TARA to be fixed at the corresponding reference ages. Our weighted mean 208Pb/232Th ages are 30.06 ± 0.22 (2σ) for SISSb, 275.4 ± 1.3 (2σ) for CAPb, and 409.9 ± 1.8 (2σ) for TARA. Precision of single spot age data varies between 1.5 and 8 % (2σ), dependent on spot size and common lead concentrations. Quadrupole LA-ICP-MS allanite age-dating has thus similar uncertainties as do other spot analysis techniques. The new data reduction technique is much less dependent on quality and homogeneity of allanite standard reference materials. This method of correcting for matrix-dependent downhole fractionation evolution opens new possibilities in the field of LA-ICP-MS data acquisition, e.g. the use of a NIST standard glass to date all material types given a set of well constrained reference materials.

  16. Heat pipe development

    NASA Technical Reports Server (NTRS)

    Bienart, W. B.

    1973-01-01

    The objective of this program was to investigate analytically and experimentally the performance of heat pipes with composite wicks--specifically, those having pedestal arteries and screwthread circumferential grooves. An analytical model was developed to describe the effects of screwthreads and screen secondary wicks on the transport capability of the artery. The model describes the hydrodynamics of the circumferential flow in triangular grooves with azimuthally varying capillary menisci and liquid cross-sections. Normalized results were obtained which give the influence of evaporator heat flux on the axial heat transport capability of the arterial wick. In order to evaluate the priming behavior of composite wicks under actual load conditions, an 'inverted' glass heat pipe was designed and constructed. The results obtained from the analysis and from the tests with the glass heat pipe were applied to the OAO-C Level 5 heat pipe, and an improved correlation between predicted and measured evaporator and transport performance were obtained.

  17. Preliminary study of the effects of a reversible chemical reaction on gas bubble dissolution. [for space glass refining

    NASA Technical Reports Server (NTRS)

    Weinberg, M. C.

    1982-01-01

    A preliminary investigation is carried out of the effects of a reversible chemical reaction on the dissolution of an isolated, stationary gas bubble in a glass melt. The exact governing equations for the model system are formulated and analyzed. The approximate quasi-steady-state version of these equations is solved analytically, and a calculation is made of bubble dissolution rates. The results are then compared with numerical solutions obtained from the finite difference form of the exact governing equations. It is pointed out that in the microgravity condition of space, the buoyant rise of a gas bubble in a glass melt will be negligible on the time scale of most experiments. For this reason, a determination of the behavior of a stationary gas bubble in a melt is relevant for an understanding of glass refining in space.

  18. Glass and Alchemy in Early Modern Europe: An Analytical Study of Glassware from the Oberstockstall Laboratory in Austria.

    PubMed

    Veronesi, Umberto; Martinón-Torres, Marcos

    2018-06-18

    Glass distillation equipment from an early modern alchemical laboratory was analyzed for its technology of manufacture and potential origin. Chemical data show that the assemblage can be divided into sodium-rich, colorless distillation vessels made with glass from Venice or its European imitation, and potassium-rich dark-brown non-specialized forms produced within the technological tradition of forest glass typical for central and north-western Europe. These results complete our understanding of the supply of technical apparatus at one of the best-preserved alchemical laboratories and highlight an early awareness of the need for high-quality instruments to guarantee the successful outcome of specialized chemical operations. This study demonstrates the potential of archaeological science to inform historical research around the practice of early chemistry and the development of modern science. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Judd-Ofelt Analysis of Dy3+-Activated Aluminosilicate Glasses Prepared by Sol-Gel Method

    NASA Astrophysics Data System (ADS)

    Sengthong, Buonyavong; Van Tuyen, Ho; An, Nguyen Thi Thai; Van Do, Phan; Hai, Nguyen Thi Quy; Chau, Pham Thi Minh; Quang, Vu Xuan

    2018-04-01

    Aluminosilicate (AS) glasses doped with different Dy3+ concentrations were synthesized via sol-gel method. Absorption, photoluminescence spectra and lifetime of this material have been studied. From analytical results of absorption spectra, the Judd-Ofelt (JO) parameters of prepared samples have been determined. These JO parameters combined with photoluminescence spectra have been used to evaluate transition probabilities ( A R), branching ratios ( β) and the calculated oscillator strengths of AS:Dy3+ glasses. The radiative branching ratio of 4F9/2 → 6H13/2 transition has a minimum value at 62.2% for β R which predicts that this transition in AS:Dy3+ glasses can give rise to lasing action. JO parameters show that the Ω2 increases with the increasing of Dy3+ ion concentration due to the increased polarizability of the average coordination medium and decreased average symmetry.

  20. A New Biocompatible and Antibacterial Phosphate Free Glass-Ceramic for Medical Applications

    NASA Astrophysics Data System (ADS)

    Cabal, Belén; Alou, Luís; Cafini, Fabio; Couceiro, Ramiro; Sevillano, David; Esteban-Tejeda, Leticia; Guitián, Francisco; Torrecillas, Ramón; Moya, José S.

    2014-06-01

    In the attempt to find valid alternatives to classic antibiotics and in view of current limitations in the efficacy of antimicrobial-coated or loaded biomaterials, this work is focused on the development of a new glass-ceramic with antibacterial performance together with safe biocompatibility. This bactericidal glass-ceramic composed of combeite and nepheline crystals in a residual glassy matrix has been obtained using an antimicrobial soda-lime glass as a precursor. Its inhibitory effects on bacterial growth and biofilm formation were proved against five biofilm-producing reference strains. The biocompatibility tests by using mesenchymal stem cells derived from human bone indicate an excellent biocompatibility.

  1. A New Biocompatible and Antibacterial Phosphate Free Glass-Ceramic for Medical Applications

    PubMed Central

    Cabal, Belén; Alou, Luís; Cafini, Fabio; Couceiro, Ramiro; Sevillano, David; Esteban-Tejeda, Leticia; Guitián, Francisco; Torrecillas, Ramón; Moya, José S.

    2014-01-01

    In the attempt to find valid alternatives to classic antibiotics and in view of current limitations in the efficacy of antimicrobial-coated or loaded biomaterials, this work is focused on the development of a new glass-ceramic with antibacterial performance together with safe biocompatibility. This bactericidal glass-ceramic composed of combeite and nepheline crystals in a residual glassy matrix has been obtained using an antimicrobial soda-lime glass as a precursor. Its inhibitory effects on bacterial growth and biofilm formation were proved against five biofilm-producing reference strains. The biocompatibility tests by using mesenchymal stem cells derived from human bone indicate an excellent biocompatibility. PMID:24961911

  2. Mesoscale Phase Field Modeling of Glass Strengthening Under Triaxial Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yulan; Sun, Xin

    2015-09-28

    Recent hydraulic bomb and confined sleeve tests on transparent armor glass materials such as borosilicate glass and soda-lime glass showed that the glass strength was a function of confinement pressure. The measured stress-strain relation is not a straight line as most brittle materials behave under little or no confinement. Moreover, borosilicate glass exhibited a stronger compressive strength when compared to soda-lime glass, even though soda-lime has higher bulk and shear moduli as well as apparent yield strength. To better understand these experimental findings, a mesoscale phase field model is developed to simulate the nonlinear stress versus strain behaviors under confinementmore » by considering heterogeneity formation under triaxial compression and the energy barrier of a micro shear banding event (referred to as pseudo-slip hereafter) in the amorphous glass. With calibrated modeling parameters, the simulation results demonstrate that the developed phase field model can quantitatively predict the pressure-dependent strength, and it can also explain the difference between the two types of glasses from the perspective of energy barrier associated with a pseudo-slip event.« less

  3. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1993 : T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for eight standard reference samples--T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)--that were distributed in October 1993 to 158 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 145 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the eight reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the eight standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  4. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1994 : T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength) and Hg-19 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1995-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 7 standard reference samples--T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength), and Hg-19 (mercury). The samples were distributed in October 1994 to 131 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 121 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  5. Two-photon excited microscale colour centre patterns in Ag-activated phosphate glass written using a focused proton beam

    NASA Astrophysics Data System (ADS)

    Kurobori, Toshio; Kada, Wataru; Shirao, Taichi; Satoh, Takahiro

    2018-02-01

    We report a demonstration of microscale patterns in Ag-activated phosphate glass fabricated using a focused proton beam with an energy range of 1-3 MeV. Various microscale patterns are based on blue and orange radiophotoluminescent (RPL) centres. Two- and three-dimensional (2D and 3D) microstructures are visualised by combining two-photon confocal microscopy with femtosecond (fs) laser pulses generated from a mode-locked Ti:sapphire laser operating at 700 nm. The reconstructed images are analytically evaluated using lateral/axial dose mapping and RPL spectra. In addition, the advantages of two-photon excitation applied to Ag-activated phosphate glass are discussed, and this method is compared with single-photon excitation.

  6. Sex-specific reference intervals of hematologic and biochemical analytes in Sprague-Dawley rats using the nonparametric rank percentile method.

    PubMed

    He, Qili; Su, Guoming; Liu, Keliang; Zhang, Fangcheng; Jiang, Yong; Gao, Jun; Liu, Lida; Jiang, Zhongren; Jin, Minwu; Xie, Huiping

    2017-01-01

    Hematologic and biochemical analytes of Sprague-Dawley rats are commonly used to determine effects that were induced by treatment and to evaluate organ dysfunction in toxicological safety assessments, but reference intervals have not been well established for these analytes. Reference intervals as presently defined for these analytes in Sprague-Dawley rats have not used internationally recommended statistical method nor stratified by sex. Thus, we aimed to establish sex-specific reference intervals for hematologic and biochemical parameters in Sprague-Dawley rats according to Clinical and Laboratory Standards Institute C28-A3 and American Society for Veterinary Clinical Pathology guideline. Hematology and biochemistry blood samples were collected from 500 healthy Sprague-Dawley rats (250 males and 250 females) in the control groups. We measured 24 hematologic analytes with the Sysmex XT-2100i analyzer, 9 biochemical analytes with the Olympus AU400 analyzer. We then determined statistically relevant sex partitions and calculated reference intervals, including corresponding 90% confidence intervals, using nonparametric rank percentile method. We observed that most hematologic and biochemical analytes of Sprague-Dawley rats were significantly influenced by sex. Males had higher hemoglobin, hematocrit, red blood cell count, red cell distribution width, mean corpuscular volume, mean corpuscular hemoglobin, white blood cell count, neutrophils, lymphocytes, monocytes, percentage of neutrophils, percentage of monocytes, alanine aminotransferase, aspartate aminotransferase, and triglycerides compared to females. Females had higher mean corpuscular hemoglobin concentration, plateletcrit, platelet count, eosinophils, percentage of lymphocytes, percentage of eosinophils, creatinine, glucose, total cholesterol and urea compared to males. Sex partition was required for most hematologic and biochemical analytes in Sprague-Dawley rats. We established sex-specific reference intervals, including corresponding 90% confidence intervals, for Sprague-Dawley rats. Understanding the significant discrepancies in hematologic and biochemical analytes between male and female Sprague-Dawley rats provides important insight into physiological effects in test rats. Establishment of locally sex-specific reference intervals allows a more precise evaluation of animal quality and experimental results of Sprague-Dawley rats in our toxicology safety assessment.

  7. U.S. Geological Survey Standard Reference Sample Project: Performance Evaluation of Analytical Laboratories

    USGS Publications Warehouse

    Long, H. Keith; Daddow, Richard L.; Farrar, Jerry W.

    1998-01-01

    Since 1962, the U.S. Geological Survey (USGS) has operated the Standard Reference Sample Project to evaluate the performance of USGS, cooperator, and contractor analytical laboratories that analyze chemical constituents of environmental samples. The laboratories are evaluated by using performance evaluation samples, called Standard Reference Samples (SRSs). SRSs are submitted to laboratories semi-annually for round-robin laboratory performance comparison purposes. Currently, approximately 100 laboratories are evaluated for their analytical performance on six SRSs for inorganic and nutrient constituents. As part of the SRS Project, a surplus of homogeneous, stable SRSs is maintained for purchase by USGS offices and participating laboratories for use in continuing quality-assurance and quality-control activities. Statistical evaluation of the laboratories results provides information to compare the analytical performance of the laboratories and to determine possible analytical deficiences and problems. SRS results also provide information on the bias and variability of different analytical methods used in the SRS analyses.

  8. Preliminary characterisation of new glass reference materials (GSA-1G, GSC-1G, GSD-1G and GSE-1G) by laser ablation-inductively coupled plasma-mass spectrometry using 193 nm, 213 nm and 266 nm wavelengths

    USGS Publications Warehouse

    Guillong, M.; Hametner, K.; Reusser, E.; Wilson, S.A.; Gunther, D.

    2005-01-01

    New glass reference materials GSA-1G, GSC-1G, GSD-1G and GSE-1G have been characterised using a prototype solid state laser ablation system capable of producing wavelengths of 193 nm, 213 nm and 266 nm. This system allowed comparison of the effects of different laser wavelengths under nearly identical ablation and ICP operating conditions. The wavelengths 213 nm and 266 nm were also used at higher energy densities to evaluate the influence of energy density on quantitative analysis. In addition, the glass reference materials were analysed using commercially available 266 nm Nd:YAG and 193 nm ArF excimer lasers. Laser ablation analysis was carried out using both single spot and scanning mode ablation. Using laser ablation ICP-MS, concentrations of fifty-eight elements were determined with external calibration to the NIST SRM 610 glass reference material. Instead of applying the more common internal standardisation procedure, the total concentration of all element oxide concentrations was normalised to 100%. Major element concentrations were compared with those determined by electron microprobe. In addition to NIST SRM 610 for external calibration, USGS BCR-2G was used as a more closely matrix-matched reference material in order to compare the effect of matrix-matched and non matrix-matched calibration on quantitative analysis. The results show that the various laser wavelengths and energy densities applied produced similar results, with the exception of scanning mode ablation at 266 nm without matrix-matched calibration where deviations up to 60% from the average were found. However, results acquired using a scanning mode with a matrix-matched calibration agreed with results obtained by spot analysis. The increased abundance of large particles produced when using a scanning ablation mode with NIST SRM 610, is responsible for elemental fractionation effects caused by incomplete vaporisation of large particles in the ICP.

  9. Influence of dust and mud on the optical, chemical, and mechanical properties of a pv protective glass

    PubMed Central

    Yilbas, Bekir Sami.; Ali, Haider; Khaled, Mazen M.; Al-Aqeeli, Nasser; Abu-Dheir, Numan; Varanasi, Kripa K.

    2015-01-01

    Recent developments in climate change have increased the frequency of dust storms in the Middle East. Dust storms significantly influence the performances of solar energy harvesting systems, particularly (photovoltaic) PV systems. The characteristics of the dust and the mud formed from this dust are examined using various analytical tools, including optical, scanning electron, and atomic force microscopies, X-ray diffraction, energy spectroscopy, and Fourier transform infrared spectroscopy. The adhesion, cohesion and frictional forces present during the removal of dry mud from the glass surface are determined using a microtribometer. Alkali and alkaline earth metal compounds in the dust dissolve in water to form a chemically active solution at the glass surface. This solution modifies the texture of the glass surface, thereby increasing the microhardness and decreasing the transmittance of the incident optical radiation. The force required to remove the dry mud from the glass surface is high due to the cohesive forces that result from the dried mud solution at the interface between the mud and the glass. The ability altering the characteristics of the glass surface could address the dust/mud-related limitations of protective surfaces and has implications for efficiency enhancements in solar energy systems. PMID:26514102

  10. Exhaled breath condensate – from an analytical point of view

    PubMed Central

    Dodig, Slavica; Čepelak, Ivana

    2013-01-01

    Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease. PMID:24266297

  11. Bioactive glasses: Importance of structure and properties in bone regeneration

    NASA Astrophysics Data System (ADS)

    Hench, Larry L.; Roki, Niksa; Fenn, Michael B.

    2014-09-01

    This review provides a brief background on the applications, mechanisms and genetics involved with use of bioactive glass to stimulate regeneration of bone. The emphasis is on the role of structural changes of the bioactive glasses, in particular Bioglass, which result in controlled release of osteostimulative ions. The review also summarizes the use of Raman spectroscopy, referred to hereto forward as bio-Raman spectroscopy, to obtain rapid, real time in vitro analysis of human cells in contact with bioactive glasses, and the osteostimulative dissolution ions that lead to osteogenesis. The bio-Raman studies support the results obtained from in vivo studies of bioactive glasses, as well as extensive cell and molecular biology studies, and thus offers an innovative means for rapid screening of new bioactive materials while reducing the need for animal testing.

  12. Intrinsic Bioprobes, Inc. (Tempe, AZ)

    DOEpatents

    Nelson, Randall W [Phoenix, AZ; Williams, Peter [Phoenix, AZ; Krone, Jennifer Reeve [Granbury, TX

    2008-07-15

    Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.

  13. Mass spectrometric immunoassay

    DOEpatents

    Nelson, Randall W; Williams, Peter; Krone, Jennifer Reeve

    2007-12-04

    Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.

  14. Mass spectrometric immunoassay

    DOEpatents

    Nelson, Randall W; Williams, Peter; Krone, Jennifer Reeve

    2013-07-16

    Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.

  15. Mass spectrometric immunoassay

    DOEpatents

    Nelson, Randall W.; Williams, Peter; Krone, Jennifer Reeve

    2005-12-13

    Rapid mass spectrometric immunoassay methods for detecting and/or quantifying antibody and antigen analytes utilizing affinity capture to isolate the analytes and internal reference species (for quantification) followed by mass spectrometric analysis of the isolated analyte/internal reference species. Quantification is obtained by normalizing and calibrating obtained mass spectrum against the mass spectrum obtained for an antibody/antigen of known concentration.

  16. Study of glass hydrometer calibration by hydrostatic weighting

    NASA Astrophysics Data System (ADS)

    Chen, Chaoyun; Wang, Jintao; Li, Zhihao; Zhang, Peiman

    2016-01-01

    Glass hydrometers are simple but effective instruments for measuring the density of liquids. Glass hydrometers calibration based on the Archimedes law, using silicon ring as a reference standard solid density, n-tridecane with density stability and low surface tension as the standard working liquid, based on hydrostatic weighing method designs a glass hydrometer calibration system. Glass hydrometer calibration system uses CCD image measurement system to align the scale of hydrometer and liquid surface, with positioning accuracy of 0.01 mm. Surface tension of the working liquid is measured by Whihemy plate. According to twice glass hydrometer weighing in the air and liquid can calculate the correction value of the current scale. In order to verify the validity of the principle of the hydrostatic weighing method of glass hydrometer calibration system, for measuring the density range of (770-790) kg/m3, with a resolution of 0.2 kg/m3 of hydrometer. The results of measurement compare with the Physikalisch-Technische Bundesanstalt(PTB) ,verifying the validity of the calibration system.

  17. Whole-rock and glass major-element geochemistry of Kilauea Volcano, Hawaii, near-vent eruptive products: September 1994 through September 2001

    USGS Publications Warehouse

    Thornber, Carl R.; Sherrod, David R.; Siems, David F.; Heliker, Christina C.; Meeker, Gregory P.; Oscarson, Robert L.; Kauahikaua, James P.

    2002-01-01

    This report presents major-element geochemical data for glasses and whole-rock aliquots among 523 lava samples collected near the vent on Kilauea's east rift zone between September 1994 and October 2001. Information on sample collection, analysis techniques and analytical standard reproducibility are presented as a PDF file, which also includes a detailed explantion of the categories of sample information presented in the database spreadsheet. The sample database is downloadable as a separate Microsoft Excel file.

  18. The kinetic origin of delayed yielding in metallic glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ye, Y. F.; Liu, X. D.; Wang, S.

    2016-06-20

    Recent experiments showed that irreversible structural change or plasticity could occur in metallic glasses (MGs) even within the apparent elastic limit after a sufficiently long waiting time. To explain this phenomenon, a stochastic shear transformation model is developed based on a unified rate theory to predict delayed yielding in MGs, which is validated afterwards through extensive atomistic simulations carried out on different MGs. On a fundamental level, an analytic framework is established in this work that links time, stress, and temperature altogether into a general yielding criterion for MGs.

  19. Deformation analysis of polymers composites: rheological model involving time-based fractional derivative

    NASA Astrophysics Data System (ADS)

    Zhou, H. W.; Yi, H. Y.; Mishnaevsky, L.; Wang, R.; Duan, Z. Q.; Chen, Q.

    2017-05-01

    A modeling approach to time-dependent property of Glass Fiber Reinforced Polymers (GFRP) composites is of special interest for quantitative description of long-term behavior. An electronic creep machine is employed to investigate the time-dependent deformation of four specimens of dog-bond-shaped GFRP composites at various stress level. A negative exponent function based on structural changes is introduced to describe the damage evolution of material properties in the process of creep test. Accordingly, a new creep constitutive equation, referred to fractional derivative Maxwell model, is suggested to characterize the time-dependent behavior of GFRP composites by replacing Newtonian dashpot with the Abel dashpot in the classical Maxwell model. The analytic solution for the fractional derivative Maxwell model is given and the relative parameters are determined. The results estimated by the fractional derivative Maxwell model proposed in the paper are in a good agreement with the experimental data. It is shown that the new creep constitutive model proposed in the paper needs few parameters to represent various time-dependent behaviors.

  20. Development of Certified Reference Materials for Diarrhetic Shellfish Poisoning Toxins, Part 1: Calibration Solutions.

    PubMed

    Beach, Daniel G; Crain, Sheila; Lewis, Nancy; LeBlanc, Patricia; Hardstaff, William R; Perez, Ruth A; Giddings, Sabrina D; Martinez-Farina, Camilo F; Stefanova, Roumiana; Burton, Ian W; Kilcoyne, Jane; Melanson, Jeremy E; Quilliam, Michael A; McCarron, Pearse

    2016-09-01

    Okadaic acid (OA) and its analogs dinophysistoxins-1 (DTX1) and -2 (DTX2) are lipophilic polyethers produced by marine dinoflagellates. These toxins accumulate in shellfish and cause diarrhetic shellfish poisoning (DSP) in humans. Regulatory testing of shellfish is essential to safeguard public health and for international trade. Certified reference materials (CRMs) play a key role in analytical monitoring programs. This paper presents an overview of the interdisciplinary work that went into the planning, production, and certification of calibration-solution CRMs for OA, DTX1, and DTX2. OA and DTX1 were isolated from large-scale algal cultures and DTX2 from naturally contaminated mussels. Toxins were isolated by a combination of extraction and chromatographic steps with processes adapted to suit the source and concentration of each toxin. New 19-epi-DSP toxin analogs were identified as minor impurities. Once OA, DTX1, and DTX2 were established to be of suitable purity, solutions were prepared and dispensed into flame-sealed glass ampoules. Certification measurements were carried out using quantitative NMR spectroscopy and LC-tandem MS. Traceability of measurements was established through certified external standards of established purity. Uncertainties were assigned following standards and guidelines from the International Organization for Standardization, with components from the measurement, stability, and homogeneity studies being propagated into final combined uncertainties.

  1. μ-PIV measurements of the ensemble flow fields surrounding a migrating semi-infinite bubble.

    PubMed

    Yamaguchi, Eiichiro; Smith, Bradford J; Gaver, Donald P

    2009-08-01

    Microscale particle image velocimetry (μ-PIV) measurements of ensemble flow fields surrounding a steadily-migrating semi-infinite bubble through the novel adaptation of a computer controlled linear motor flow control system. The system was programmed to generate a square wave velocity input in order to produce accurate constant bubble propagation repeatedly and effectively through a fused glass capillary tube. We present a novel technique for re-positioning of the coordinate axis to the bubble tip frame of reference in each instantaneous field through the analysis of the sudden change of standard deviation of centerline velocity profiles across the bubble interface. Ensemble averages were then computed in this bubble tip frame of reference. Combined fluid systems of water/air, glycerol/air, and glycerol/Si-oil were used to investigate flows comparable to computational simulations described in Smith and Gaver (2008) and to past experimental observations of interfacial shape. Fluorescent particle images were also analyzed to measure the residual film thickness trailing behind the bubble. The flow fields and film thickness agree very well with the computational simulations as well as existing experimental and analytical results. Particle accumulation and migration associated with the flow patterns near the bubble tip after long experimental durations are discussed as potential sources of error in the experimental method.

  2. Abrasion Resistance and Mechanical Properties of Waste-Glass-Fiber-Reinforced Roller-compacted Concrete

    NASA Astrophysics Data System (ADS)

    Yildizel, S. A.; Timur, O.; Ozturk, A. U.

    2018-05-01

    The potential use of waste glass fibers in roller-compacted concrete (RCC) was investigated with the aim to improve its performance and reduce environmental effects. The research was focused on the abrasion resistance and compressive and flexural strengths of the reinforced concrete relative to those of reference mixes without fibers. The freeze-thaw resistance of RCC mixes was also examined. It was found that the use of waste glass fibers at a rate of 2 % increased the abrasion resistance of the RCC mixes considerably.

  3. Acousto-Optic Applications for Multichannel Adaptive Optical Processor

    DTIC Science & Technology

    1992-06-01

    AO cell and the two- channel line-scan camera system described in Subsection 4.1. The AO material for this IntraAction AOD-70 device was flint glass (n...Single-Channel 1.68 (flint glass ) 60,.0 AO Cell Multichannel 2.26 (TeO 2) 20.0 AO Cell Beam splitter 1.515 ( glass ) 50.8 Multichannel correlation was...Tone Intermodulation Dynamic Ranges of Longitudinal TeO2 Bragg Cells for Several Acoustic Power Densities 4-92 f f2 f 3 1 t SOURCE: Reference 21 TR-92

  4. Surface Analysis of Nerve Agent Degradation Products by ...

    EPA Pesticide Factsheets

    Report This sampling and analytical procedure was developed and applied by a single laboratory to investigate nerve agent degradation products, which may persist at a contaminated site, via surface wiping followed by analytical characterization. The performance data presented demonstrate the fitness-for-purpose regarding surface analysis in that single laboratory. Surfaces (laminate, glass, galvanized steel, vinyl tile, painted drywall and treated wood) were wiped with cotton gauze wipes, sonicated, extracted with distilled water, and filtered. Samples were analyzed with direct injection electrospray ionization liquid chromatography tandem mass spectrometry (ESI-LC/MS/MS) without derivatization. Detection limit data were generated for all analytes of interest on a laminate surface. Accuracy and precision data were generated from each surface fortified with these analytes.

  5. Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

    PubMed

    Al-Saidi, H M; Al-Harbi, Sami A; Aljuhani, E H; El-Shahawi, M S

    2016-10-01

    A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries. Copyright © 2016. Published by Elsevier B.V.

  6. USGS48 Puerto Rico precipitation - A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Tarbox, Lauren V.; Lorenz, Jennifer M.; Scholl, Martha A.

    2014-01-01

    A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.

  7. An investigation of the feasibility of applying Raman microscopy for exploring stained glass

    NASA Astrophysics Data System (ADS)

    Bouchard, Michel; Smith, David C.; Carabatos-Nédelec, Constantin

    2007-12-01

    Raman microscopy (RM) is widely used in archaeometrical studies of pigments, geomaterials and biomaterials in the Cultural Heritage, but one domain has received relatively less attention: the colouring of stained glass. This feasibility study investigates the advantages and disadvantages of employing RM alone in this field by means of a study of modern commercial glasses, modern commercial pigments, and a few archaeological stained glasses, but especially by an experimental project whereby the authors created stained glass. The different kinds of possible unreacted or reacted material are rigorously established. The distinction between Na, K, Ca glasses was explored, as well as the red colouring of an industrial glass which was proved to be due to the presence of (Zn, Cd)S xSe 1- x. Yellow, green, blue and maroon pigments were studied before and after an initial firing and then after heating on glass. The quality of the Raman spectra varied enormously and was sometimes disappointing. Nevertheless RM successfully identified various coloured products such as bindheimite, crocoite, cobalt aluminate, haematite; relict reactants such as corundum, eskolaite and oxides of Co or Pb; and provided indications of other phases such as maghemite or Co-olivine. One conclusion is that the amount of chemical reaction between the pigments and the glass is small compared to the amount in between the pigments. Comments are made on the potential for dating archaeological glass from the known age of synthesis of the pigments, and of the dangers of this approach. Overall it has been shown that RM can be useful for studying stained glass, especially for remote in situ analytical operations with mobile RM, but one must expect some problems either with fluorescence or weak spectra.

  8. In situ LA-ICPMS U–Pb dating of cassiterite without a known-age matrix-matched reference material: Examples from worldwide tin deposits spanning the Proterozoic to the Tertiary

    USGS Publications Warehouse

    Neymark, Leonid; Holm-Denoma, Christopher S.; Moscati, Richard J.

    2018-01-01

    Cassiterite (SnO2), a main ore mineral in tin deposits, is suitable for U–Pb isotopic dating because of its relatively high U/Pb ratios and typically low common Pb. We report a LA-ICPMS analytical procedure for U–Pb dating of this mineral with no need for an independently dated matrix-matched cassiterite standard. LA-ICPMS U-Th-Pb data were acquired while using NIST 612 glass as a primary non-matrix-matched standard. Raw data are reduced using a combination of Iolite™ and other off-line data reduction methods. Cassiterite is extremely difficult to digest, so traditional approaches in LA-ICPMS U-Pb geochronology that utilize well-characterized matrix-matched reference materials (e.g., age values determined by ID-TIMS) cannot be easily implemented. We propose a new approach for in situ LA-ICPMS dating of cassiterite, which benefits from the unique chemistry of cassiterite with extremely low Th concentrations (Th/U ratio of 10−4 or lower) in some cassiterite samples. Accordingly, it is assumed that 208Pb measured in cassiterite is mostly of non-radiogenic origin—it was initially incorporated in cassiterite during mineral formation, and can be used as a proxy for common Pb. Using 208Pb as a common Pb proxy instead of 204Pb is preferred as 204Pb is much less abundant and is also compromised by 204Hg interference during the LA-ICPMS analyses.Our procedure relies on 208Pb/206Pb vs 207Pb/206Pb (Pb-Pb) and Tera-Wasserburg 207Pb/206Pb vs 238U/206Pb (U-Pb) isochron dates that are calculated for a ~1.54 Ga low-Th cassiterite reference material with varying amounts of common Pb that we assume remained a closed U-Pb system. The difference between the NIST 612 glass normalized biased U-Pb date and the Pb-Pb age of the reference material is used to calculate a correction factor (F) for instrumental U-Pb fractionation. The correction factor (F) is then applied to measured U/Pb ratios and Tera-Wasserburg isochron dates are obtained for the unknown cassiterite analyzed in the same analytical session. This allows for U-Pb dating of cassiterite of any age with no need for an independently dated matrix-matched reference material, nor assumptions about the isotopic composition of common Pb.Results for cassiterite from tin deposits in Bolivia, Brazil, China, Russia, Saudi Arabia, South Africa, Spain, and the United Kingdom, with ages ranging from ~20 Ma to ~2060 Ma, demonstrate the applicability of this approach across a broad range of geologic time. These ages are in good agreement with published geochronology of the host rocks associated with the tin deposits and with previously published U-Pb ages of some cassiterites from the same deposits. Thus, our in situ LA-ICPMS methodology verifies the use of cassiterite as a reliable U-Pb mineral-geochronometer with the advantages of fast and relatively low cost in situ analyses with moderate spatial resolution.

  9. The fate of silicon during glass corrosion under alkaline conditions: A mechanistic and kinetic study with the International Simple Glass

    NASA Astrophysics Data System (ADS)

    Gin, Stéphane; Jollivet, Patrick; Fournier, Maxime; Berthon, Claude; Wang, Zhaoying; Mitroshkov, Alexandre; Zhu, Zihua; Ryan, Joseph V.

    2015-02-01

    International Simple Glass - a six oxide borosilicate glass selected by the international nuclear glass community to improve the understanding of glass corrosion mechanisms and kinetics - was altered at 90 °C in a solution initially saturated with respect to amorphous 29SiO2. The pH90°C, was fixed at 9 at the start of the experiment and raised to 11.5 after 209 d by the addition of KOH. Isotope sensitive analytical techniques were used to analyze the solution and altered glass samples, helping to understand the driving forces and rate limiting processes controlling long-term glass alteration. At pH 9, the corrosion rate continuously drops and the glass slowly transforms into a uniform, homogeneous amorphous alteration layer. The mechanisms responsible for this transformation are water penetration through the growing alteration layer and ion exchange. We demonstrate that this amorphous alteration layer is not a precipitate resulting from the hydrolysis of the silicate network; it is mostly inherited from the glass structure from which the most weakly bonded cations (Na, Ca and B) have been released. At pH 11.5, the alteration process is very different: the high solubility of glass network formers (Si, Al, Zr) triggers the rapid and complete dissolution of the glass (dissolution becomes congruent) and precipitation of amorphous and crystalline phases. Unlike at pH 9 where glass corrosion rate decreased by 3 orders of magnitude likely due to the retroaction of the alteration layer on water dynamics/reactivity at the reaction front, the rate at pH 11.5 is maintained at a value close to the forward rate due to both the hydrolysis of the silicate network promoted by OH- and the precipitation of CSH and zeolites. This study provides key information for a unified model for glass dissolution.

  10. Sintering and crystallization behavior of CaMgSi{sub 2}O{sub 6}-NaFeSi{sub 2}O{sub 6} based glass-ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goel, Ashutosh; Kansal, Ishu; Dipartimento di Ingegneria dei Materiali e dell'Ambiente, Facolta di Ingegneria, Universita di Modena e Reggio Emilia, 41100 Modena

    2009-11-01

    We report on the synthesis, sintering, and crystallization behaviors of a glass with a composition corresponding to 90 mol % CaMgSi{sub 2}O{sub 6}-10 mol % NaFeSi{sub 2}O{sub 6}. The investigated glass composition crystallized superficially immediately after casting of the melt and needs a high cooling rate (rapid quenching) in order to produce an amorphous glass. Differential thermal analysis and hot-stage microscopy were employed to investigate the glass forming ability, sintering behavior, relative nucleation rate, and crystallization behavior of the glass composition. The crystalline phase assemblage in the glass-ceramics was studied under nonisothermal heating conditions in the temperature range of 850-950more » deg. C in both air and N{sub 2} atmosphere. X-ray diffraction studies adjoined with the Rietveld-reference intensity ratio method were employed to quantify the amount of crystalline phases, while electron microscopy was used to shed some light on the microstructure of the resultant glass-ceramics. Well sintered glass-ceramics with diopside as the primary crystalline phase were obtained where the amount of diopside varied with the heating conditions.« less

  11. Effect of clayey groundwater on the dissolution rate of SON68 simulated nuclear waste glass at 70 °C

    NASA Astrophysics Data System (ADS)

    De Echave, T.; Tribet, M.; Jollivet, P.; Marques, C.; Gin, S.; Jégou, C.

    2018-05-01

    To predict the long-term behavior of high-level radioactive waste glass, it is necessary to study aqueous dissolution of the glass matrix under geological repository conditions. The present article focuses on SON68 (an inactive surrogate of the R7T7 glass) glass alteration in synthetic clayey groundwater at 70 °C. Experiments in deionized water as reference were also performed in the same conditions. Results are in agreement with those of previous studies showing that magnesium present in the solution is responsible for higher glass alteration. This effect is transient and pH-dependent: Once all the magnesium is consumed, the glass alteration rate diminishes. Precipitation of magnesium silicate of the smectite group seems to be the main factor for the increased glass alteration. A pH threshold of 7.5-7.8 was found, above which precipitation of these magnesium silicates at 70 °C is possible. TEM observations reveal that magnesium silicates grow at the expense of the passivating gel, which partly dissolves, forming large pores which increase mass transfer between the reacting glass surface and the bulk solution.

  12. Applications of nanopipettes in the analytical sciences.

    PubMed

    Morris, Celeste A; Friedman, Alicia K; Baker, Lane A

    2010-09-01

    In this review, we describe measurements and applications of interest to the analytical community that makes use of simple nanopipettes. Fabricated by applying heat during the separation of a glass capillary, nanopipettes provide a route for nanoscale studies of ion transport and for development of chemical and biochemical sensors. When mounted on a translation stage, nanopipettes also enable unique modes of imaging and material deposition. These facets of nanopipette research, as well as some of the unique properties of nanopipettes, will be discussed.

  13. Tetraethyl orthosilicate-based glass composition and method

    DOEpatents

    Wicks, George G.; Livingston, Ronald R.; Baylor, Lewis C.; Whitaker, Michael J.; O'Rourke, Patrick E.

    1997-01-01

    A tetraethyl orthosilicate-based, sol-gel glass composition with additives selected for various applications. The composition is made by mixing ethanol, water, and tetraethyl orthosilicate, adjusting the pH into the acid range, and aging the mixture at room temperature. The additives, such as an optical indicator, filler, or catalyst, are then added to the mixture to form the composition which can be applied to a substrate before curing. If the additive is an indicator, the light-absorbing characteristics of which vary upon contact with a particular analyte, the indicator can be applied to a lens, optical fiber, reagant strip, or flow cell for use in chemical analysis. Alternatively, an additive such as alumina particles is blended into the mixture to form a filler composition for patching cracks in metal, glass, or ceramic piping.

  14. Glassy Behavior due to Kinetic Constraints: from Topological Foam to Backgammon

    NASA Astrophysics Data System (ADS)

    Sherrington, David

    A study is reported of a series of simple model systems with only non-interacting Hamiltonians, and hence simple equilibrium thermodynamics, but with constrained kinetics of a type initially suggested by topological considerations of foams and two-dimensional covalent glasses. It is demonstrated that oscopic dynamical features characteristic of real glasses, such as two-time decays in energy and auto-correlation functions, arise and may be understood in terms of annihilation-diffusion concepts and theory. This recognition leads to a sequence of further models which (i) encapsulate the essense but are more readily simulated and open to easier analytic study, and (ii) allow generalization and extension to higher dimension. Fluctuation-dissipation relations are also considered and show novel aspects. The comparison is with strong glasses.

  15. A reference web architecture and patterns for real-time visual analytics on large streaming data

    NASA Astrophysics Data System (ADS)

    Kandogan, Eser; Soroker, Danny; Rohall, Steven; Bak, Peter; van Ham, Frank; Lu, Jie; Ship, Harold-Jeffrey; Wang, Chun-Fu; Lai, Jennifer

    2013-12-01

    Monitoring and analysis of streaming data, such as social media, sensors, and news feeds, has become increasingly important for business and government. The volume and velocity of incoming data are key challenges. To effectively support monitoring and analysis, statistical and visual analytics techniques need to be seamlessly integrated; analytic techniques for a variety of data types (e.g., text, numerical) and scope (e.g., incremental, rolling-window, global) must be properly accommodated; interaction, collaboration, and coordination among several visualizations must be supported in an efficient manner; and the system should support the use of different analytics techniques in a pluggable manner. Especially in web-based environments, these requirements pose restrictions on the basic visual analytics architecture for streaming data. In this paper we report on our experience of building a reference web architecture for real-time visual analytics of streaming data, identify and discuss architectural patterns that address these challenges, and report on applying the reference architecture for real-time Twitter monitoring and analysis.

  16. Product stewardship and science: safe manufacture and use of fiber glass.

    PubMed

    Hesterberg, Thomas W; Anderson, Robert; Bernstein, David M; Bunn, William B; Chase, Gerald A; Jankousky, Angela Libby; Marsh, Gary M; McClellan, Roger O

    2012-03-01

    This paper describes a proactive product stewardship program for glass fibers. That effort included epidemiological studies of workers, establishment of stringent workplace exposure limits, liaison with customers on safe use of products and, most importantly, a research program to evaluate the safety of existing glass fiber products and guide development of new even safer products. Chronic inhalation exposure bioassays were conducted with rodents and hamsters. Amosite and crocidolite asbestos produced respiratory tract cancers as did exposure to "biopersistent" synthetic vitreous fibers. "less biopersistent" glass fibers did not cause respiratory tract cancers. Corollary studies demonstrated the role of slow fiber dissolution rates and biopersistence in cancer induction. These results guided development of safer glass fiber products and have been used in Europe to regulate fibers and by IARC and NTP in classifying fibers. IARC concluded special purpose fibers and refractory ceramic fibers are "possibly carcinogenic to humans" and insulation glass wool, continuous glass filament, rock wool and slag wool are "not classifiable as to their carcinogenicity to human." The NTP's 12th report on carcinogens lists "Certain Glass Wool Fibers (Inhalable)" as "reasonably anticipated to be a human carcinogen." "Certain" in the descriptor refers to "biopersistent" glass fibers and excludes "less biopersistent" glass fibers. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. HPLC-MS method for the quantification of nine anti-HIV drugs from dry plasma spot on glass filter and their long term stability in different conditions.

    PubMed

    D'Avolio, Antonio; Simiele, Marco; Siccardi, Marco; Baietto, Lorena; Sciandra, Mauro; Bonora, Stefano; Di Perri, Giovanni

    2010-09-05

    A bioanalytical method for the determination of most commonly prescribed protease inhibitors (saquinavir, atazanavir, amprenavir, darunavir, lopinavir and ritonavir) and non-nucleoside reverse transcriptase inhibitors (etravirine, efavirenz and nevirapine) was developed, modifying our previous HPLC-MS chromatographic run, validated and a complete short and long term stability evaluation was carried out. One hundred microlitres of plasma were distributed on a collection glass paper filter (Glass-Microfibre from Sartorius), then the filter underwent thermal treatment, both for drying and for HIV inactivation, and stored at room temperature, 4 degrees C and -20 degrees C. The analytes were extracted from the filter disc using tert-butylmethylether with basic pH, after the addition of the internal standards quinoxaline. The extract was dried, reconstituted and the chromatographic separation was performed on a reversed-phase C-18 column (150 mm x 2.0 mm) and the analytes were quantified using a single quadrupole mass spectrometer. The method was validated considering the concentration ranges encountered in clinical trials and the routine clinical practice. The assay was linear over the concentration ranges tested. Accuracies ranged from 92.1% to 111.9% and intra-day and inter-day relative standard deviation for all quality control levels ranged from 0.2 to 12.9 and 3.1 to 14.4, respectively. Analytes in dried plasma spots were stable for longer time when dried/inactivation step was carried out before storage compared to samples not dried/inactivated before the analysis. The dried/inactivation step allows shipment of samples at room temperature without any risks, therefore the developed and validated method enables an easy and cheap sample shipment for therapeutic drug monitoring and pharmacokinetic studies. 2010 Elsevier B.V. All rights reserved.

  18. Association of glass fragments by their trace elemental content using ICP-MS and LA-ICP-MS in the analysis scheme

    NASA Astrophysics Data System (ADS)

    Almirall, Jose R.; Montero, Shirly; Furton, Kenneth G.

    2002-08-01

    The importance of glass as evidence of association between a crime event and a suspect has been recognized for some time. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. The physical and chemical properties of glass can be used to differentiate between possible sources and as evidence of association between two fragments of glass thought to originate from the same source. Refractive index (RI) comparisons have been used for this purpose but due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses, even if the glass originates from different sources. Elemental analysis methods such as NAA, XRF, ICP-AES, and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) have also been used for the comparison of trace elemental compositions and these techniques have been shown to provide an improvement in the discrimination of glass fragments over RI comparisons alone. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The methodology for solution analysis (digestion procedure) and solid sample analysis (laser ablation) of glass is reported and the analytical results are compared. An isotope dilution method is also reported as a high precision technique for elemental analysis of glass fragments. The optimum sampling parameters for laser ablation, for semi-quantitative analysis and element ratio comparisons are also presented. Finally, the results of a case involving the breaking of 15 vehicle windows in an airport parking lot and the association of a suspect to the breakings by the glass fragments found on his person are also presented.

  19. Repair of through thickness corrosion/leaking defects in corroded pipelines using Fiber Reinforced Polymer overwrap

    NASA Astrophysics Data System (ADS)

    Nitheesh Kumar, P.; Khan, Vishwas Chandra; Balaganesan, G.; Pradhan, A. K.; Sivakumar, M. S.

    2018-04-01

    The present study is concerned with the repair of through thickness corrosion or leaking defects in metallic pipelines using a commercially available metallic seal and glass/epoxy composite. Pipe specimens are made with three different types of most commonly occurring through thickness corrosion/leaking defects. The metallic seal is applied over the through thickness corrosion/leaking defect and it is reinforced with glass/epoxy composite overwrap. The main objective of the metallic seal is to arrest the leak at live pressure. After reinforcing the metallic seal with glass/epoxy composite overwrap, the repaired composite wrap is able to sustain high pressures. Burst test is performed for different configurations of metallic seal and optimum configuration of metallic seal is determined. The optimum configurations of metallic seal for three different types of through thickness corrosion/leaking defects are further reinforced with glass/epoxy composite wrap and experimental failure pressure is determined by performing the burst test. An analytical model as per ISO 24817 has been developed to validate experimental results.

  20. Children's Glasses

    NASA Astrophysics Data System (ADS)

    Akerskog, Gunnar; Soderlund, Jan

    1980-07-01

    There is a common opinion among eye specialists and opticians that children's glasses often are not shaped for optimal fitting. A fundamental reason for this is the lack of data for the shaping of the bows, with the result that most children's glasses are reduced copies of adult's glasses. This report describes a photogrammetric method for collection of primary data for manufac-turing bows for children. An ordinary amateur camera was equipped with a stereo-adapter. With a few arrangements, such as projecting a pattern on the face and keeping the hair away from the ears, 600 children were photographed. A calibration photograph was exposed at the beginning and end of each film or when the equipment had been transported or otherwise disturbed. The photographs were measured in a stereocomparator and the coordinates analytically corrected for distortion. After determination of model coordinates the requested geometric information, such as pupillar distance, eye-ear distance, location of the bridge of the nose etc, was calculated. The shapes of average noses were presented as profile plots.

  1. Volcanic Coatings on Picritic Apollo 17 Glasses; Submicrometer-Deposits of Fe-CR-Metal

    NASA Technical Reports Server (NTRS)

    McKay, David S.; Wentworth, S. J.; Thomas-Keprta, K. L.; Ross, K.; Clementt, S. J.

    2010-01-01

    The purposes of our ongoing investigations of Apollo 15 green and Apollo 17 orange and black volcanic glasses are threefold: first, to increase our understanding of the volcanic origin of the glasses; second, to determine the nature of the coating materials deposited on the glasses during their cooling in the volcanic environment; and, third, to help determine the nature of the gases involved in the volcanic fire-fountaining that occurred at approximately 3.5 Ga on the moon. We are continuing studies of coatings on volcanic glasses using analytical techniques not available when these glasses were originally studied; these include high-resolution FE-TEM and X-ray mapping, along with other highly detailed methods including TEM electron diffraction analysis. Initial studies of Apollo 15 green volcanic glasses using the techniques described above revealed for the first time the presence of areas containing distinct layering of volcanic surface deposits. S was associated with some of the inner layer of metallic Fe but was absent from the outer layer. Zn was associated with S in some places in the inner layer. An example of a typical spherule used for this study is shown in Fig. 1. It is a black (quench-crystallized) bead from near the bottom of the 74001/2 double drive tube; black beads such as this one are essentially identical in composition to the orange (uncrystallized) beads of the 74001/2 core.

  2. Glass Fragment Hazard from Windows Broken by Airblast

    DTIC Science & Technology

    1980-05-30

    Reference 2). Velocities, masses, and spetial distributions of frao- ments have been mfeasured by trapping the fragments in Sty.roFoam 0 ( expanded ... polystyrene ) "witness plates located behind windows in houses subjected to large chiemical or nuclear ex- plosions (References 3 and 4). Yields ranged

  3. Ultrapure glass optical waveguide development in microgravity by the sol-gel process

    NASA Technical Reports Server (NTRS)

    Mukherjee, S. P.; Holman, R. A.

    1981-01-01

    Multicomponent, homogeneous, noncrystalline oxide gels can be prepared by the sol-gel process and these gels are promising starting materials for melting glasses in the space environment. The sol-gel process referred to here is based on the polymerization reaction of alkoxysilane with other metal alkoxy compounds or suitable metal salts. Many of the alkoxysilanes or other metal alkoxides are liquids and thus can be purified by distillation. The use of gels offers several advantages such as high purity and lower melting times and temperatures. The sol-gel process is studied for utilization in the preparation of multicomponent ultrapure glass batches for subsequent containerless melting of the batches in space to prepare glass blanks for optical waveguides.

  4. USGS46 Greenland ice core water – A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Coplen, Tyler B.; Qi, Haiping; Tarbox, Lauren V.; Lorenz, Jennifer M.; Buck, Bryan

    2015-01-01

    Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured δ2H and δ18O values of this reference water were −235.8 ± 0.7‰ and −29.80 ± 0.03‰, respectively, relative to VSMOW on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.

  5. A glass capillary based microfluidic electromembrane extraction of basic degradation products of nitrogen mustard and VX from water.

    PubMed

    Tak, Vijay; Kabra, Ankur; Pardasani, Deepak; Goud, D Raghavender; Jain, Rajeev; Dubey, D K

    2015-12-24

    In this work, a glass capillary based microfluidic electromembrane extraction (μ-EME) was demonstrated for the first time. The device was made by connecting an auxillary borosilicate glass tubing (O.D. 3mm, I.D. 2mm) perpendicular to main borosilicate glass capillary just below one end of the capillary (O.D. 8mm, I.D. 1.2mm). It generated the distorted T-shaped device with inlet '1' and inlet '2' for the introduction of sample and acceptor solutions, respectively. At one end of this device (inlet '2'), a microsyringe containing acceptor solution along with hollow fiber (O.D. 1000μm) was introduced. This configuration creates the micro-channel between inner wall of glass capillary and outer surface of hollow fiber. Sample solution was pumped into the system through another end of glass capillary (inlet '1'), with a micro-syringe pump. The sample was in direct contact with the supported liquid membrane (SLM), consisted of 20% (w/w) di-(2-ethylhexyl)phosphate in 2-nitrophenyl octyl ether immobilized in the pores of the hollow fiber. In the lumen of the hollow fiber, the acceptor phase was present. The driving force for extraction was direct current (DC) electrical potential sustained over the SLM. Highly polar (logP=-2.5 to 1.4) basic degradation products of nitrogen mustard and VX were selected as model analytes. The influence of chemical composition of SLM, extraction time, voltage and pH of donor and acceptor phase were investigated. The model analytes were extracted from 10μL of pure water with recoveries ranging from 15.7 to 99.7% just after 3min of operation time. Under optimized conditions, good limits of detection (2-50ngmL(-1)), linearity (from 5-1000 to 100-1000ngmL(-1)), and repeatability (RSDs below 11.9%, n=3) were achieved. Applicability of the proposed μ-EME was proved by recovering triethanolamine (31.3%) from 10μL of five times diluted original water sample provided by the Organization for the Prohibition of Chemical Weapons during 28th official proficiency test. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Complex dynamics induced by strong confinement - From tracer diffusion in strongly heterogeneous media to glassy relaxation of dense fluids in narrow slits

    NASA Astrophysics Data System (ADS)

    Mandal, Suvendu; Spanner-Denzer, Markus; Leitmann, Sebastian; Franosch, Thomas

    2017-08-01

    We provide an overview of recent advances of the complex dynamics of particles in strong confinements. The first paradigm is the Lorentz model where tracers explore a quenched disordered host structure. Such systems naturally occur as limiting cases of binary glass-forming systems if the dynamics of one component is much faster than the other. For a certain critical density of the host structure the tracers undergo a localization transition which constitutes a critical phenomenon. A series of predictions in the vicinity of the transition have been elaborated and tested versus computer simulations. Analytical progress is achieved for small obstacle densities. The second paradigm is a dense strongly interacting liquid confined to a narrow slab. Then the glass transition depends nonmonotonically on the separation of the plates due to an interplay of local packing and layering. Very small slab widths allow to address certain features of the statics and dynamics analytically.

  7. Relation between the structural parameters of metallic glasses at the onset crystallization temperatures and threshold values of the effective diffusion coefficients

    NASA Astrophysics Data System (ADS)

    Tkatch, V. I.; Svyrydova, K. A.; Vasiliev, S. V.; Kovalenko, O. V.

    2017-08-01

    Using the results of differential scanning calorimetry and X-ray diffractometry, an analysis has been carried out of the initial stages of the eutectic and primary mechanisms of crystallization of a series of metallic glasses based on Fe and Al with the established temperature dependences of the effective diffusion coefficients. Analytical relationships, which relate the volume density of crystallites formed in the glasses at the temperatures of the onset of crystallization with the values of the effective diffusion coefficients at these temperatures have been proposed. It has been established that, in the glasses, the crystallization of which begins at the lower boundary of the threshold values of the effective diffusion coefficients ( 10-20 m2/s), structures are formed with the volume density of crystallites on the order of 1023-1024 m-3 and, at the upper boundary (10-18 m2/s), of the order of 1018 and 1020 m-3 in the glasses that are crystallized via the eutectic and primary mechanisms, respectively. Good agreement between the calculated and experimental estimates indicates that the threshold values of the effective diffusion coefficients are the main factors that determine the structure of glasses at the initial stages of crystallization.

  8. Fiber sensor on the basis of Ge26As17Se25Te32 glass for FEWS analysis

    NASA Astrophysics Data System (ADS)

    Velmuzhov, A. P.; Shiryaev, V. S.; Sukhanov, M. V.; Kotereva, T. V.; Churbanov, M. F.; Zernova, N. S.; Plekhovich, A. D.

    2018-01-01

    The high-purity Ge26As17Se25Te32 glass sample was prepared by chemical distillation purification method. This glass is characterized by high value of glass transition temperature (263°С), high optical transparency in the spectral range of 2-10 μm, and low content of residual impurities. The Ge26As17Se25Te32 glass rods were drawn into single-index fibers using the "rod" method and the single crucible technique. The optical losses in the 400 μm diameter fiber, fabricated by the "rod" method, were within 0.3-1 dB/m in the spectral range 5.2-9.3 μm. The minimum optical losses in the 320 μm diameter fiber, fabricated by the "crucible" technique, were 1.6-1.7 dB/m in the spectral range 6-8.5 μm. Using these Ge26As17Se25Te32 glass fibers as a sensor, the aqueous solutions of acetone (0-20 mol.%) and ethanol (0-90 mol.%) were analyzed by fiber evanescent wave spectroscopy. Peculiarities in the change of the integrated intensity and spectral position of absorption bands of these organic substances in dependence on the analyte composition and the length of the sensitive zone were established.

  9. Relaxation and physical aging in network glasses: a review.

    PubMed

    Micoulaut, Matthieu

    2016-06-01

    Recent progress in the description of glassy relaxation and aging are reviewed for the wide class of network-forming materials such as GeO2, Ge x Se1-x , silicates (SiO2-Na2O) or borates (B2O3-Li2O), all of which have an important usefulness in domestic, geological or optoelectronic applications. A brief introduction of the glass transition phenomenology is given, together with the salient features that are revealed both from theory and experiments. Standard experimental methods used for the characterization of the slowing down of the dynamics are reviewed. We then discuss the important role played by aspects of network topology and rigidity for the understanding of the relaxation of the glass transition, while also permitting analytical predictions of glass properties from simple and insightful models based on the network structure. We also emphasize the great utility of computer simulations which probe the dynamics at the molecular level, and permit the calculation of various structure-related functions in connection with glassy relaxation and the physics of aging which reveal the non-equilibrium nature of glasses. We discuss the notion of spatial variations of structure which leads to the concept of 'dynamic heterogeneities', and recent results in relation to this important topic for network glasses are also reviewed.

  10. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    PubMed

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  11. Improvement in degradability of 58s glass scaffolds by ZnO and β-TCP modification

    PubMed Central

    Shuai, Cijun; Cao, Yiyuan; Dan, Gao; Gao, Chengde; Feng, Pei; Wu, Ping

    2016-01-01

    ABSTRACT 58s bioactive glass shows great potential for bone defects repair. However, at early repairing stage, the degradation rate of 58s glass is too fast due to the fast ion-exchange. At later repairing stage, the degradation rate of 58s glass is too slow due to the high dense mineral layer. In this work, Zinc oxide (ZnO) and β-tricalcium phosphate (β-TCP) were introduced into 58s glass bone scaffolds to improve the degradability. The results showed that ZnO could decrease the degradation rate and promote the stability of 58s glass at early repairing stage. Moreover, the presence of β-TCP appeared to increase the degradation rate at a later stage of repairing. Furthermore, in vitro biocompatibility study, carried out using human osteoblast-like cells (MG63), demonstrated that ZnO and β-TCP enhanced cell attachment and proliferation. The study provided a reference for further research in bone tissue engineering. PMID:27710432

  12. Ion concentration in micro and nanoscale electrospray emitters.

    PubMed

    Yuill, Elizabeth M; Baker, Lane A

    2018-06-01

    Solution-phase ion transport during electrospray has been characterized for nanopipettes, or glass capillaries pulled to nanoscale tip dimensions, and micron-sized electrospray ionization emitters. Direct visualization of charged fluorophores during the electrospray process is used to evaluate impacts of emitter size, ionic strength, analyte size, and pressure-driven flow on heterogeneous ion transport during electrospray. Mass spectrometric measurements of positively- and negatively-charged proteins were taken for micron-sized and nanopipette emitters under low ionic strength conditions to further illustrate a discrepancy in solution-driven transport of charged analytes. A fundamental understanding of analyte electromigration during electrospray, which is not always considered, is expected to provide control over selective analyte depletion and enrichment, and can be harnessed for sample cleanup. Graphical abstract Fluorescence micrographs of ion migration in nanoscale pipettes while solution is electrosprayed.

  13. Isotopic Analysis of Uranium in NIST SRM Glass by Femtosecond Laser Ablation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duffin, Andrew M.; Hart, Garret L.; Hanlen, Richard C.

    We employed femtosecond Laser Ablation Multicollector Inductively Coupled Mass Spectrometry for the 11 determination of uranium isotope ratios in a series of standard reference material glasses (NIST 610, 612, 614, and 12 616). This uranium concentration in this series of SRM glasses is a combination of isotopically natural uranium in 13 the materials used to make the glass matrix and isotopically depleted uranium added to increase the uranium 14 elemental concentration across the series. Results for NIST 610 are in excellent agreement with literature values. 15 However, other than atom percent 235U, little information is available for the remaining glasses.more » We present atom 16 percent and isotope ratios for 234U, 235U, 236U, and 238U for all four glasses. Our results show deviations from the 17 certificate values for the atom percent 235U, indicating the need for further examination of the uranium isotopes in 18 NIST 610-616. Our results are fully consistent with a two isotopic component mixing between the depleted 19 uranium spike and natural uranium in the bulk glass.« less

  14. Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.

    PubMed

    Lo, Y C; Armbruster, David A

    2012-04-01

    Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.

  15. Glass transition behavior of ternary disaccharide-ethylene glycol-water solutions

    NASA Astrophysics Data System (ADS)

    Yu, Tongxu; Zhao, Lishan; Wang, Qiang; Cao, Zexian

    2017-06-01

    Glass transition behavior of ternary disaccharide-ethylene glycol-water solutions, in reference to that of the binary combinations, has been investigated towards a better understanding of their cryoprotective ability. In water-deficient solutions, the disaccharides, including trehalose, sucrose and maltose, can associate with more than 100 ethylene glycol molecules to form amorphous complex, one order of magnitude larger than the corresponding hydration numbers. In water-rich solutions, a second glass transition emerges with increasing molar fraction of ethylene glycol, indicating the possible synergy of disaccharides and ethylene glycol in vitrification of the ternary aqueous solution.

  16. Adherence to AHA Guidelines When Adapted for Augmented Reality Glasses for Assisted Pediatric Cardiopulmonary Resuscitation: A Randomized Controlled Trial

    PubMed Central

    Gervaix, Alain; Haddad, Kevin; Lacroix, Laurence; Schrurs, Philippe; Sahin, Ayhan; Lovis, Christian; Manzano, Sergio

    2017-01-01

    Background The American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) are nowadays recognized as the world’s most authoritative resuscitation guidelines. Adherence to these guidelines optimizes the management of critically ill patients and increases their chances of survival after cardiac arrest. Despite their availability, suboptimal quality of CPR is still common. Currently, the median hospital survival rate after pediatric in-hospital cardiac arrest is 36%, whereas it falls below 10% for out-of-hospital cardiac arrest. Among emerging information technologies and devices able to support caregivers during resuscitation and increase adherence to AHA guidelines, augmented reality (AR) glasses have not yet been assessed. In order to assess their potential, we adapted AHA Pediatric Advanced Life Support (PALS) guidelines for AR glasses. Objective The study aimed to determine whether adapting AHA guidelines for AR glasses increased adherence by reducing deviation and time to initiation of critical life-saving maneuvers during pediatric CPR when compared with the use of PALS pocket reference cards. Methods We conducted a randomized controlled trial with two parallel groups of voluntary pediatric residents, comparing AR glasses to PALS pocket reference cards during a simulation-based pediatric cardiac arrest scenario—pulseless ventricular tachycardia (pVT). The primary outcome was the elapsed time in seconds in each allocation group, from onset of pVT to the first defibrillation attempt. Secondary outcomes were time elapsed to (1) initiation of chest compression, (2) subsequent defibrillation attempts, and (3) administration of drugs, as well as the time intervals between defibrillation attempts and drug doses, shock doses, and number of shocks. All these outcomes were assessed for deviation from AHA guidelines. Results Twenty residents were randomized into 2 groups. Time to first defibrillation attempt (mean: 146 s) and adherence to AHA guidelines in terms of time to other critical resuscitation endpoints and drug dose delivery were not improved using AR glasses. However, errors and deviations were significantly reduced in terms of defibrillation doses when compared with the use of the PALS pocket reference cards. In a total of 40 defibrillation attempts, residents not wearing AR glasses used wrong doses in 65% (26/40) of cases, including 21 shock overdoses >100 J, for a cumulative defibrillation dose of 18.7 Joules per kg. These errors were reduced by 53% (21/40, P<.001) and cumulative defibrillation dose by 37% (5.14/14, P=.001) with AR glasses. Conclusions AR glasses did not decrease time to first defibrillation attempt and other critical resuscitation endpoints when compared with PALS pocket cards. However, they improved adherence and performance among residents in terms of administering the defibrillation doses set by AHA. PMID:28554878

  17. Analytical performance specifications for changes in assay bias (Δbias) for data with logarithmic distributions as assessed by effects on reference change values.

    PubMed

    Petersen, Per H; Lund, Flemming; Fraser, Callum G; Sölétormos, György

    2016-11-01

    Background The distributions of within-subject biological variation are usually described as coefficients of variation, as are analytical performance specifications for bias, imprecision and other characteristics. Estimation of specifications required for reference change values is traditionally done using relationship between the batch-related changes during routine performance, described as Δbias, and the coefficients of variation for analytical imprecision (CV A ): the original theory is based on standard deviations or coefficients of variation calculated as if distributions were Gaussian. Methods The distribution of between-subject biological variation can generally be described as log-Gaussian. Moreover, recent analyses of within-subject biological variation suggest that many measurands have log-Gaussian distributions. In consequence, we generated a model for the estimation of analytical performance specifications for reference change value, with combination of Δbias and CV A based on log-Gaussian distributions of CV I as natural logarithms. The model was tested using plasma prolactin and glucose as examples. Results Analytical performance specifications for reference change value generated using the new model based on log-Gaussian distributions were practically identical with the traditional model based on Gaussian distributions. Conclusion The traditional and simple to apply model used to generate analytical performance specifications for reference change value, based on the use of coefficients of variation and assuming Gaussian distributions for both CV I and CV A , is generally useful.

  18. Some new features of Direct Analysis in Real Time mass spectrometry utilizing the desorption at an angle option.

    PubMed

    Chernetsova, Elena S; Revelsky, Alexander I; Morlock, Gertrud E

    2011-08-30

    The present study is a first step towards the unexplored capabilities of Direct Analysis in Real Time (DART) mass spectrometry (MS) arising from the possibility of the desorption at an angle: scanning analysis of surfaces, including the coupling of thin-layer chromatography (TLC) with DART-MS, and a more sensitive analysis due to the preliminary concentration of analytes dissolved in large volumes of liquids on glass surfaces. In order to select the most favorable conditions for DART-MS analysis, proper positioning of samples is important. Therefore, a simple and cheap technique for the visualization of the impact region of the DART gas stream onto a substrate was developed. A filter paper or TLC plate, previously loaded with the analyte, was immersed in a derivatization solution. On this substrate, owing to the impact of the hot DART gas, reaction of the analyte to a colored product occurred. An improved capability of detection of DART-MS for the analysis of liquids was demonstrated by applying large volumes of model solutions of coumaphos into small glass vessels and drying these solutions prior to DART-MS analysis under ambient conditions. This allowed the introduction of, by up to more than two orders of magnitude, increased quantities of analyte compared with the conventional DART-MS analysis of liquids. Through this improved detectability, the capabilities of DART-MS in trace analysis could be strengthened. Copyright © 2011 John Wiley & Sons, Ltd.

  19. The influence of SrO and CaO in silicate and phosphate bioactive glasses on human gingival fibroblasts.

    PubMed

    Massera, J; Kokkari, A; Närhi, T; Hupa, L

    2015-06-01

    In this paper, we investigate the effect of substituting SrO for CaO in silicate and phosphate bioactive glasses on the human gingival fibroblast activity. In both materials the presence of SrO led to the formation of a CaP layer with partial Sr substitution for Ca. The layer at the surface of the silicate glass consisted of HAP whereas at the phosphate glasses it was close to the DCPD composition. In silicate glasses, SrO gave a faster initial dissolution and a thinner reaction layer probably allowing for a continuous ion release into the solution. In phosphate glasses, SrO decreased the dissolution process and gave a more strongly bonded reaction layer. Overall, the SrO-containing silicate glass led to a slight enhancement in the activity of the gingival fibroblasts cells when compared to the SrO-free reference glass, S53P4. The cell activity decreased up to 3 days of culturing for all phosphate glasses containing SrO. Whereas culturing together with the SrO-free phosphate glass led to complete cell death at 7 days. The glasses containing SrO showed rapid cell proliferation and growth between 7 and 14 days, reaching similar activity than glass S53P4. The addition of SrO in both silicate and phosphate glasses was assumed beneficial for proliferation and growth of human gingival fibroblasts due to Sr incorporation in the reaction layer at the glass surface and released in the cell culture medium.

  20. Magnetic glass-film based on single-nanosize 𝜺 -Fe2O3 nanoparticles

    NASA Astrophysics Data System (ADS)

    Yoshikiyo, Marie; Namai, Asuka; Nakagawa, Kosuke; Ohkoshi, Shin-ichi

    2017-05-01

    We report a magnetic thin film of single-nanosize ɛ-Fe2O3 in SiO2 matrix. The glass-film was prepared by sintering a silica coated iron oxide hydroxide on a quartz substrate in air. The glass-film consists of ɛ-Fe2O3 of 8.8 nm size, and its thickness was 570 nm (0.57 μm) with a roughness of 10 nm (0.01 μm). UV-vis spectrum showed that the glass-film has small absorbance of 0.043 at 500 nm. The magneto-optical effect was investigated, and Faraday ellipticity showed a magnetic hysteresis loop with a coercive field of 3.0 ± 0.2 kOe. Furthermore, single-nanosize ɛ-Fe2O3 without silica was prepared as a reference sample, and ferroelectricity was observed. Therefore, the present thin glass-film consists of single-nanosize ferroelectric-ferromagnetic nanoparticles.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, G.L.

    This data package satisfies the requirement for a format IV, final report. It is a follow-up to the 45-day safety screen report for tank AP-104. Evaporator candidate feed from tank 241-AP-104 (hereafter referred to as AP-104) was characterized for physical, inorganic, organic and radiochemical parameters by the Westinghouse Hanford Company, 222-S Laboratory, and by the Battelle Pacific Northwest National Laboratory (PNNL), Analytical Chemistry Laboratory (ACL) as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report tomore » enable early estimation of evaporator operational parameters, using the Predict modeling program. Laboratory analyses at ACL Laboratory was performed according to the TSAP. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory`s Quality Assurance Plan, References 5 and 6. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation. SAMPLING The TSAP, section 2, provided sampling information for waste samples collected from tank AP-104. The bottle-on-a-string method was used to collect liquid grab samples from the tank. Each glass sample bottle was amber, precleaned, and contained approximately 100 milliliters. Each bottle was closed with a teflon seal cap (or teflon septum for volatile organic analysis samples). Field blank samples were prepared by placing deionized water into sampling bottles, lowering the unclosed bottles into the riser for a period of time, retrieving them from the riser, and then closing the bottles with the same types of caps used for the tank samples. None of the samples were preserved by acidification. Upon receipt, the sample bottles destined for organic analyses were placed in a refrigerator. No attempt was made during sampling to assure the complete filling of the bottles so as to exclude all headspace. These actions were consistent with safety procedures, which attempt to limit personnel exposure to hazardous ionizing radiation.« less

  2. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.

    2014-01-01

    RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. 

  3. Optoelectrofluidic enhanced immunoreaction based on optically-induced dynamic AC electroosmosis.

    PubMed

    Han, Dongsik; Park, Je-Kyun

    2016-04-07

    We report a novel optoelectrofluidic immunoreaction system based on electroosmotic flow for enhancing antibody-analyte binding efficiency on a surface-based sensing system. Two conventional indium tin oxide glass slides are assembled to provide a reaction chamber for a tiny volume of sample droplet (∼5 μL), in which the top layer is employed as an antibody-immobilized substrate and the bottom layer acts as a photoconductive layer of an optoelectrofluidic device. Under the application of an AC voltage, an illuminated light pattern on the photoconductive layer causes strong counter-rotating vortices to transport analytes from the bulk solution to the vicinity of the assay spot on the glass substrate. This configuration overcomes the slow immunoreaction problem of a diffusion-based sensing system, resulting in the enhancement of binding efficiency via an optoelectrofluidic method. Furthermore, we investigate the effect of optically-induced dynamic AC electroosmotic flow on optoelectrofluidic enhancement for surface-based immunoreaction with a mathematical simulation study and real experiments using immunoglobulin G (IgG) and anti-IgG. As a result, dynamic light patterns provided better immunoreaction efficiency than static light patterns due to effective mass transport of the target analyte, resulting in an achievement of 2.18-fold enhancement under a growing circular light pattern compared to the passive mode.

  4. In situ laser-induced photochemical silver substrate synthesis and sequential SERS detection in a flow cell.

    PubMed

    Herman, Krisztian; Szabó, László; Leopold, Loredana F; Chiş, Vasile; Leopold, Nicolae

    2011-05-01

    A new, simple, and effective approach for multianalyte sequential surface-enhanced Raman scattering (SERS) detection in a flow cell is reported. The silver substrate was prepared in situ by laser-induced photochemical synthesis. By focusing the laser on the 320 μm inner diameter glass capillary at 0.5 ml/min continuous flow of 1 mM silver nitrate and 10 mM sodium citrate mixture, a SERS active silver spot on the inner wall of the glass capillary was prepared in a few seconds. The test analytes, dacarbazine, 4-(2-pyridylazo)resorcinol (PAR) complex with Cu(II), and amoxicillin, were sequentially injected into the flow cell. Each analyte was adsorbed to the silver surface, enabling the recording of high intensity SERS spectra even at 2 s integration times, followed by desorption from the silver surface and being washed away from the capillary. Before and after each analyte passed the detection window, citrate background spectra were recorded, and thus, no "memory effects" perturbed the SERS detection. A good reproducibility of the SERS spectra obtained under flow conditions was observed. The laser-induced photochemically synthesized silver substrate enables high Raman enhancement, is characterized by fast preparation with a high success rate, and represents a valuable alternative for silver colloids as SERS substrate in flow approaches.

  5. Electrophoretic extraction of low molecular weight cationic analytes from sodium dodecyl sulfate containing sample matrices for their direct electrospray ionization mass spectrometry.

    PubMed

    Kinde, Tristan F; Lopez, Thomas D; Dutta, Debashis

    2015-03-03

    While the use of sodium dodecyl sulfate (SDS) in separation buffers allows efficient analysis of complex mixtures, its presence in the sample matrix is known to severely interfere with the mass-spectrometric characterization of analyte molecules. In this article, we report a microfluidic device that addresses this analytical challenge by enabling inline electrospray ionization mass spectrometry (ESI-MS) of low molecular weight cationic samples prepared in SDS containing matrices. The functionality of this device relies on the continuous extraction of analyte molecules into an SDS-free solvent stream based on the free-flow zone electrophoresis (FFZE) technique prior to their ESI-MS analysis. The reported extraction was accomplished in our current work in a glass channel with microelectrodes fabricated along its sidewalls to realize the desired electric field. Our experiments show that a key challenge to successfully operating such a device is to suppress the electroosmotically driven fluid circulations generated in its extraction channel that otherwise tend to vigorously mix the liquid streams flowing through this duct. A new coating medium, N-(2-triethoxysilylpropyl) formamide, recently demonstrated by our laboratory to nearly eliminate electroosmotic flow in glass microchannels was employed to address this issue. Applying this surface modifier, we were able to efficiently extract two different peptides, human angiotensin I and MRFA, individually from an SDS containing matrix using the FFZE method and detect them at concentrations down to 3.7 and 6.3 μg/mL, respectively, in samples containing as much as 10 mM SDS. Notice that in addition to greatly reducing the amount of SDS entering the MS instrument, the reported approach allows rapid solvent exchange for facilitating efficient analyte ionization desired in ESI-MS analysis.

  6. Tetraethyl orthosilicate-based glass composition and method

    DOEpatents

    Wicks, G.G.; Livingston, R.R.; Baylor, L.C.; Whitaker, M.J.; O`Rourke, P.E.

    1997-06-10

    A tetraethyl orthosilicate-based, sol-gel glass composition with additives selected for various applications is described. The composition is made by mixing ethanol, water, and tetraethyl orthosilicate, adjusting the pH into the acid range, and aging the mixture at room temperature. The additives, such as an optical indicator, filler, or catalyst, are then added to the mixture to form the composition which can be applied to a substrate before curing. If the additive is an indicator, the light-absorbing characteristics of which vary upon contact with a particular analyte, the indicator can be applied to a lens, optical fiber, reagent strip, or flow cell for use in chemical analysis. Alternatively, an additive such as alumina particles is blended into the mixture to form a filler composition for patching cracks in metal, glass, or ceramic piping. 12 figs.

  7. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    PubMed

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. The Asian project for collaborative derivation of reference intervals: (1) strategy and major results of standardized analytes.

    PubMed

    Ichihara, Kiyoshi; Ceriotti, Ferruccio; Tam, Tran Huu; Sueyoshi, Shigeo; Poon, Priscilla M K; Thong, Mee Ling; Higashiuesato, Yasushi; Wang, Xuejing; Kataoka, Hiromi; Matsubara, Akemi; Shiesh, Shu-Chu; Muliaty, Dewi; Kim, Jeong-Ho; Watanabe, Masakazu; Lam, Christopher W K; Siekmann, Lothar; Lopez, Joseph B; Panteghini, Mauro

    2013-07-01

    A multicenter study conducted in Southeast Asia to derive reference intervals (RIs) for 72 commonly measured analytes (general chemistry, inflammatory markers, hormones, etc.) featured centralized measurement to clearly detect regionality in test results. The results of 31 standardized analytes are reported, with the remaining analytes presented in the next report. The study included 63 clinical laboratories from South Korea, China, Vietnam, Malaysia, Indonesia, and seven areas in Japan. A total of 3541 healthy individuals aged 20-65 years (Japan 2082, others 1459) were recruited mostly from hospital workers using a well-defined common protocol. All serum specimens were transported to Tokyo at -80°C and collectively measured using reagents from four manufacturers. Three-level nested ANOVA was used to quantitate variation (SD) of test results due to region, sex, and age. A ratio of SD for a given factor over residual SD (representing net between-individual variations) (SDR) exceeding 0.3 was considered significant. Traceability of RIs was ensured by recalibration using value-assigned reference materials. RIs were derived parametrically. SDRs for sex and age were significant for 19 and 16 analytes, respectively. Regional difference was significant for 11 analytes, including high density lipoprotein (HDL)-cholesterol and inflammatory markers. However, when the data were limited to those from Japan, regionality was not observed in any of the analytes. Accordingly, RIs were derived with or without partition by sex and region. RIs applicable to a wide area in Asia were established for the majority of analytes with traceability to reference measuring systems, whereas regional partitioning was required for RIs of the other analytes.

  9. Capabilities and limitations of handheld Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for the analysis of colourants and binders in 20th-century reverse paintings on glass

    NASA Astrophysics Data System (ADS)

    Steger, Simon; Stege, Heike; Bretz, Simone; Hahn, Oliver

    2018-04-01

    A non-invasive method has been carried out to show the capabilities and limitations of Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for identifying of colourants and binders in modern reverse glass paintings. For this purpose, the reverse glass paintings "Zwei Frauen am Tisch" (1920-22), "Bäume" (1946) (both by Heinrich Campendonk), "Lofoten" (1933) (Edith Campendonk-van Leckwyck) and "Ohne Titel" (1954) (Marianne Uhlenhuth), were measured. In contrast to other techniques (e.g. panel and mural painting), the paint layers are applied in reverse succession. In multi-layered paint systems, the front paint layer may no longer be accessible. The work points out the different spectral appearance of a given substance (gypsum, basic lead white) in reverse glass paintings. However, inverted bands, band overlapping and derivative-shaped spectral features can be interpreted by comparing the spectra from the paintings with spectra from pure powders and pigment/linseed oil mock-ups. Moreover, the work focuses on this method's capabilities in identifying synthetic organic pigments (SOP). Reference spectra of three common SOP (PG7, PY1, PR83) were obtained from powders and historical colour charts. We identified PR83 and PY1 in two reverse glass paintings, using the measured reference spectra. The recorded DRIFTS spectra of pure linseed oil, gum Arabic, mastic, polyvinyl acetate resin and bees wax can be used to classify the binding media of the measured paintings.

  10. On Statistical Approaches for Demonstrating Analytical Similarity in the Presence of Correlation.

    PubMed

    Yang, Harry; Novick, Steven; Burdick, Richard K

    Analytical similarity is the foundation for demonstration of biosimilarity between a proposed product and a reference product. For this assessment, currently the U.S. Food and Drug Administration (FDA) recommends a tiered system in which quality attributes are categorized into three tiers commensurate with their risk and approaches of varying statistical rigor are subsequently used for the three-tier quality attributes. Key to the analyses of Tiers 1 and 2 quality attributes is the establishment of equivalence acceptance criterion and quality range. For particular licensure applications, the FDA has provided advice on statistical methods for demonstration of analytical similarity. For example, for Tier 1 assessment, an equivalence test can be used based on an equivalence margin of 1.5 σ R , where σ R is the reference product variability estimated by the sample standard deviation S R from a sample of reference lots. The quality range for demonstrating Tier 2 analytical similarity is of the form X̄ R ± K × σ R where the constant K is appropriately justified. To demonstrate Tier 2 analytical similarity, a large percentage (e.g., 90%) of test product must fall in the quality range. In this paper, through both theoretical derivations and simulations, we show that when the reference drug product lots are correlated, the sample standard deviation S R underestimates the true reference product variability σ R As a result, substituting S R for σ R in the Tier 1 equivalence acceptance criterion and the Tier 2 quality range inappropriately reduces the statistical power and the ability to declare analytical similarity. Also explored is the impact of correlation among drug product lots on Type I error rate and power. Three methods based on generalized pivotal quantities are introduced, and their performance is compared against a two-one-sided tests (TOST) approach. Finally, strategies to mitigate risk of correlation among the reference products lots are discussed. A biosimilar is a generic version of the original biological drug product. A key component of a biosimilar development is the demonstration of analytical similarity between the biosimilar and the reference product. Such demonstration relies on application of statistical methods to establish a similarity margin and appropriate test for equivalence between the two products. This paper discusses statistical issues with demonstration of analytical similarity and provides alternate approaches to potentially mitigate these problems. © PDA, Inc. 2016.

  11. Sol-gel chemical sensors for surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Lee, Vincent Y.; Farquharson, Stuart; Kwon, Hueong-Chan; Shahriari, Mahmoud R.; Rainey, Petrie M.

    1999-02-01

    Surface-enhanced Raman spectroscopy (SERS) promises to be one of the most sensitive methods for chemical detection. Unfortunately, the inability of SERS to perform quantitative chemical analysis has slowed its general use in laboratories. This is largely due to the difficulty of manufacturing either active surfaces that yield reproducible enhancements, or surfaces that are capable of reversible chemical adsorption, or both. In an effort to meet this need, we have developed metal-doped sol-gels that provide surface-enhancement of Raman scattering. The porous silica network offers a unique environment for stabilizing SER active metal particles and the high surface area increases the interaction between the analyte and metal particles. This eliminates the need to concentrate the analyte on the surface by evaporating the solvent. The sol-gel is easily coated on a variety of surfaces, such as fiber optics, glass slides, or glass tubing, and can be designed into sample flow systems. Here we present the development of both gold- and silver-doped sol-gels, which have been used to coat the inside walls of glass sample vials for SERS applications. The performance of the metal-doped sol-gels was evaluated using p-aminobenzoic acid, to establish enhancement factors, detection limits, dynamic response range, reversibility, reproducibility, and suitability to commercial spectrometers. Measurements of trace chemicals, such as adenine and cocaine, are also presented.

  12. Breaking through the Glass Doors: Men Working in Early Childhood Education and Care with Particular Reference to Research and Experience in Austria and New Zealand

    ERIC Educational Resources Information Center

    Koch, Bernhard; Farquhar, Sarah

    2015-01-01

    This article proposes that there exist "glass doors" impeding men from entering and participating in ECEC work. Across developed countries, men's participation as carers and teachers in early childhood education and care (ECEC) services tends to be viewed as highly desirable and much has been written about the importance of men in ECEC.…

  13. Castable and High Modulus Acoustic Dampening Material

    DTIC Science & Technology

    2007-02-22

    high impact strength and high dampening laminate structures (e.g., fiberglass parts, etc.). It appears that a carboxy-terminated butadiene nitrile ( CTBN ...Sanjana reference also states that the preferred glass transition temperature for the CTBNs is "<-200". The greater the difference from room...temperature (or the temperature of interest) that the glass transition of the CTBN is, the less acoustic or vibrational energy will be absorbed/dampened

  14. Short-time vibrational dynamics of metaphosphate glasses

    NASA Astrophysics Data System (ADS)

    Kalampounias, Angelos G.

    2012-02-01

    In this paper we present the picosecond vibrational dynamics of a series of binary metaphosphate glasses, namely Na2O-P2O5, MO-P2O5 (M=Ba, Sr, Ca, Mg) and Al2O3-3P2O5 by means of Raman spectroscopy. We studied the vibrational dephasing and vibrational frequency modulation by calculating time correlation functions of vibrational relaxation by fits in the frequency domain. The fitting method used enables one to model the real line profiles intermediate between Lorentzian and Gaussian by an analytical function, which has an analytical counterpart in the time domain. The symmetric stretching modes νs(PO2-) and νs(P-O-P) of the PO2- entity of PØ2O2- units and of P-O-P bridges in metaphosphate arrangements have been investigated by Raman spectroscopy and we used them as probes of the dynamics of these glasses. The vibrational time correlation functions of both modes studied are rather adequately interpreted within the assumption of exponential modulation function in the context of Kubo-Rothschield theory and indicate that the system experiences an intermediate dynamical regime that gets only slower with an increase in the ionic radius of the cation-modifier. We found that the vibrational correlation functions of all glasses studied comply with the Rothschild approach assuming that the environmental modulation is described by a stretched exponential decay. The evolution of the dispersion parameter α with increasing ionic radius of the cation indicates the deviation from the model simple liquid indicating the reduction of the coherence decay in the perturbation potential as a result of local short lived aggregates. The results are discussed in the framework of the current phenomenological status of the field.

  15. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children

    PubMed Central

    Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young

    2016-01-01

    Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715

  16. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.

    PubMed

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young

    2016-09-01

    Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.

  17. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).

  18. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    NASA Astrophysics Data System (ADS)

    Nerilli, Francesca; Vairo, Giuseppe

    2016-06-01

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  19. Analytical modeling of soliton interactions in a nonlocal nonlinear medium analogous to gravitational force

    NASA Astrophysics Data System (ADS)

    Zeng, Shihao; Chen, Manna; Zhang, Ting; Hu, Wei; Guo, Qi; Lu, Daquan

    2018-01-01

    We illuminate an analytical model of soliton interactions in lead glass by analogizing to a gravitational force system. The orbits of spiraling solitons under a long-range interaction are given explicitly and demonstrated to follow Newton's second law of motion and the Binet equation by numerical simulations. The condition for circular orbits is obtained and the oscillating orbits are proved not to be closed. We prove the analogy between the nonlocal nonlinear optical system and gravitational system and specify the quantitative relation of the quantity between the two models.

  20. Analysis of Wastewater for Organic Compounds Unique to RDX/HMX manufacturing and Processing

    DTIC Science & Technology

    1979-12-01

    Evaporation 6.. ............ 6 Analytical Separation’and Identification.• 6Gas Chromatography. 6 Liquid Chromatography ( LC )’and’Infrared Analyses (iR...steam-heated system. This conclusion was arrived at by comparing chromatograms relative to numbers of, and intensity of the component peaks . Analytical...for chromatographing the samples are listed below: (1) 10% UC-W-98 on Chrom G-AW-DMCS 0.61 m x 6.3 mm (2 ft. x ¼ in.) glass col umn (2) 10% UC-W-98 on

  1. Low thermal flux glass-fiber tubing for cryogenic service

    NASA Technical Reports Server (NTRS)

    Hall, C. A.; Spond, D. E.

    1977-01-01

    This paper describes analytical techniques, fabrication development, and test results for composite tubing that has many applications in aerospace and commercial cryogenic installations. Metal liner fabrication is discussed in detail with attention given to resistance-welded liners, fusion-welded liners, chem-milled tubing liners, joining tube liners and end fittings, heat treatment and leak checks. Composite overwrapping, a second method of tubing fabrication, is also discussed. Test programs and analytical correlation are considered along with composite tubing advantages such as minimum weight, thermal efficiency and safety and reliability.

  2. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nerilli, Francesca; Vairo, Giuseppe

    2016-06-08

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  3. Approximate chemical analysis of volcanic glasses using Raman spectroscopy

    PubMed Central

    Morgavi, Daniele; Hess, Kai‐Uwe; Neuville, Daniel R.; Borovkov, Nikita; Perugini, Diego; Dingwell, Donald B.

    2015-01-01

    The effect of chemical composition on the Raman spectra of a series of natural calcalkaline silicate glasses has been quantified by performing electron microprobe analyses and obtaining Raman spectra on glassy filaments (~450 µm) derived from a magma mingling experiment. The results provide a robust compositionally‐dependent database for the Raman spectra of natural silicate glasses along the calcalkaline series. An empirical model based on both the acquired Raman spectra and an ideal mixing equation between calcalkaline basaltic and rhyolitic end‐members is constructed enabling the estimation of the chemical composition and degree of polymerization of silicate glasses using Raman spectra. The model is relatively insensitive to acquisition conditions and has been validated using the MPI‐DING geochemical standard glasses1 as well as further samples. The methods and model developed here offer several advantages compared with other analytical and spectroscopic methods such as infrared spectroscopy, X‐ray fluorescence spectroscopy, electron and ion microprobe analyses, inasmuch as Raman spectroscopy can be performed with a high spatial resolution (1 µm2) without the need for any sample preparation as a nondestructive technique. This study represents an advance in efforts to provide the first database of Raman spectra for natural silicate glasses and yields a new approach for the treatment of Raman spectra, which allows us to extract approximate information about the chemical composition of natural silicate glasses using Raman spectroscopy. We anticipate its application in handheld in situ terrestrial field studies of silicate glasses under extreme conditions (e.g. extraterrestrial and submarine environments). © 2015 The Authors Journal of Raman Spectroscopy Published by John Wiley & Sons Ltd PMID:27656038

  4. Effects of Deficient Reporting on Meta-Analysis: A Conceptual Framework and Reanalysis

    ERIC Educational Resources Information Center

    Orwin, Robert G.; Cordray, David S.

    1985-01-01

    Identifies three sources of reporting deficiency for meta-analytic results: quality (adequacy) of publicizing; quality of macrolevel reporting, and quality of microlevel reporting. Reanalysis of 25 reports from the Smith, Glass and Miller (1980) psychotherapy meta-analysis established two sources of misinformation, interrater reliabilities and…

  5. The NIH analytical methods and reference materials program for dietary supplements.

    PubMed

    Betz, Joseph M; Fisher, Kenneth D; Saldanha, Leila G; Coates, Paul M

    2007-09-01

    Quality of botanical products is a great uncertainty that consumers, clinicians, regulators, and researchers face. Definitions of quality abound, and include specifications for sanitation, adventitious agents (pesticides, metals, weeds), and content of natural chemicals. Because dietary supplements (DS) are often complex mixtures, they pose analytical challenges and method validation may be difficult. In response to product quality concerns and the need for validated and publicly available methods for DS analysis, the US Congress directed the Office of Dietary Supplements (ODS) at the National Institutes of Health (NIH) to accelerate an ongoing methods validation process, and the Dietary Supplements Methods and Reference Materials Program was created. The program was constructed from stakeholder input and incorporates several federal procurement and granting mechanisms in a coordinated and interlocking framework. The framework facilitates validation of analytical methods, analytical standards, and reference materials.

  6. PXRF, μ-XRF, vacuum μ-XRF, and EPMA analysis of Email Champlevé objects present in Belgian museums.

    PubMed

    Van der Linden, Veerle; Meesdom, Eva; Devos, Annemie; Van Dooren, Rita; Nieuwdorp, Hans; Janssen, Elsje; Balace, Sophie; Vekemans, Bart; Vincze, Laszlo; Janssens, Koen

    2011-10-01

    The enamel of 20 Email Champlevé objects dating between the 12th and 19th centuries was investigated by means of microscopic and portable X-ray fluorescence analysis (μ-XRF and PXRF). Seven of these objects were microsampled and the fragments were analyzed with electron probe microanalysis (EPMA) and vacuum μ-XRF to obtain quantitative data about the composition of the glass used to produce these enameled objects. As a result of the evolution of the raw materials employed to produce the base glass, three different compositional groups could be discriminated. The first group consisted of soda-lime-silica glass with a sodium source of mineral origin (with low K content) that was opacified by addition of calcium antimonate crystals. This type of glass was only used in objects made in the 12th century. Email Champlevé objects from the beginning of the 13th century onward were enameled with soda-lime-silica glass with a sodium source of vegetal origin. This type of glass, which has a higher potassium content, was opacified with SnO2 crystals. The glass used for 19th century Email Champlevé artifacts was produced with synthetic and purified components resulting in a different chemical composition compared to the other groups. Although the four analytical techniques employed in this study have their own specific characteristics, they were all found to be suitable for classifying the objects into the different chronological categories.

  7. Effects of optical dopants and laser wavelength on atom probe tomography analyses of borosilicate glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Xiaonan; Schreiber, Daniel K.; Neeway, James J.

    Atom probe tomography (APT) is a novel analytical microscopy method that provides three dimensional elemental mapping with sub-nanometer spatial resolution and has only recently been applied to insulating glass and ceramic samples. In this paper, we have studied the influence of the optical absorption in glass samples on APT characterization by introducing different transition metal optical dopants to a model borosilicate nuclear waste glass (international simple glass). A systematic comparison is presented of the glass optical properties and the resulting APT data quality in terms of compositional accuracy and the mass spectra quality for two APT systems: one with amore » green laser (532 nm, LEAP 3000X HR) and one with a UV laser (355 nm, LEAP 4000X HR). These data were also compared to the study of a more complex borosilicate glass (SON68). The results show that the analysis data quality such as compositional accuracy and total ions collected, was clearly linked to optical absorption when using a green laser, while for the UV laser optical doping aided in improving data yield but did not have a significant effect on compositional accuracy. Comparisons of data between the LEAP systems suggest that the smaller laser spot size of the LEAP 4000X HR played a more critical role for optimum performance than the optical dopants themselves. The smaller spot size resulted in more accurate composition measurements due to a reduced background level independent of the material’s optical properties.« less

  8. 77 FR 32632 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Hydrogen Peroxide Filter Extraction'' In this method, total suspended particulate matter (TSP) is collected on glass fiber filters according to 40 CFR Appendix G to part 50, EPA Reference Method for the Determination of Lead in Suspended Particulate Matter Collected From Ambient Air. The filter samples are...

  9. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    PubMed

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Smart-Glasses: Exposing and Elucidating the Ethical Issues.

    PubMed

    Hofmann, Bjørn; Haustein, Dušan; Landeweerd, Laurens

    2017-06-01

    The objective of this study is to provide an overview over the ethical issues relevant to the assessment, implementation, and use of smart-glasses. The purpose of the overview is to facilitate deliberation, decision making, and the formation of knowledge and norms for this emerging technology. An axiological question-based method for human cognitive enhancement including an extensive literature search on smart-glasses is used to identify relevant ethical issues. The search is supplemented with relevant ethical issues identified in the literature on human cognitive enhancement (in general) and in the study of the technical aspects of smart-glasses. Identified papers were subject to traditional content analysis: 739 references were identified of which 247 were regarded as relevant for full text examinations, and 155 were included in the study. A wide variety of ethical issues with smart-glasses have been identified, such as issues related to privacy, safety, justice, change in human agency, accountability, responsibility, social interaction, power and ideology. Smart-glasses are envisioned to change individual human identity and behavior as well as social interaction. Taking these issues into account appears to be relevant when developing, deliberating, deciding on, implementing, and using smart-glasses.

  11. Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams.

    PubMed

    Mizuno, Hideyuki; Kanai, Tatsuaki; Kusano, Yohsuke; Ko, Susumu; Ono, Mari; Fukumura, Akifumi; Abe, Kyoko; Nishizawa, Kanae; Shimbo, Munefumi; Sakata, Suoh; Ishikura, Satoshi; Ikeda, Hiroshi

    2008-02-01

    The characteristics of a glass dosimeter were investigated for its potential use as a tool for postal dose audits. Reproducibility, energy dependence, field size and depth dependence were compared to those of a thermoluminescence dosimeter (TLD), which has been the major tool for postal dose audits worldwide. A glass dosimeter, GD-302M (Asahi Techno Glass Co.) and a TLD, TLD-100 chip (Harshaw Co.) were irradiated with gamma-rays from a (60)Co unit and X-rays from a medical linear accelerator (4, 6, 10 and 20 MV). The dosimetric characteristics of the glass dosimeter were almost equivalent to those of the TLD, in terms of utility for dosimetry under the reference condition, which is a 10 x 10 cm(2) field and 10 cm depth. Because of its reduced fading, compared to the TLD, and easy quality control with the ID number, the glass dosimeter proved to be a suitable tool for postal dose audits. Then, we conducted postal dose surveys of over 100 facilities and got good agreement, with a standard deviation of about 1.3%. Based on this study, postal dose audits throughout Japan will be carried out using a glass dosimeter.

  12. Validation of the determination of the B isotopic composition in Roman glasses with laser ablation multi-collector inductively coupled plasma-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Devulder, Veerle; Gerdes, Axel; Vanhaecke, Frank; Degryse, Patrick

    2015-03-01

    The applicability of laser ablation multi-collector inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) for the determination of the B isotopic composition in Roman glasses was investigated. The δ11B values thus obtained provide information on the natron flux used during the glass-making process. The glass samples used for this purpose were previously characterized using pneumatic nebulization (PN) MC-ICP-MS. Unfortunately, this method is time-consuming and labor-intensive and consumes some 100 mg of sample, which is a rather high amount for ancient materials. Therefore, the use of the less invasive and faster LA-MC-ICP-MS approach was explored. In this work, the results for 29 Roman glasses and 4 home-made glasses obtained using both techniques were compared to assess the suitability of LA-MC-ICP-MS in this context. The results are in excellent agreement within experimental uncertainty. No difference in overall mass discrimination was observed between the Roman glasses, NIST SRM 610 reference glass and B6 obsidian. The expanded uncertainty of the LA-MC-ICP-MS approach was estimated to be < 2‰, which is similar to that obtained upon sample digestion and PN-MC-ICP-MS measurement.

  13. Pulmonary fibrosis in a carpenter with long-lasting exposure to fiberglass.

    PubMed

    Takahashi, T; Munakata, M; Takekawa, H; Homma, Y; Kawakami, Y

    1996-11-01

    A 56-year-old male carpenter had a history of glass fiber inhalation for 41 years without any protective device. His chest radiograph showed small nodular opacities in lower lung fields and multiple cystic lesions and low attenuation areas in upper lung fields. Light and polarizing microscopic examinations of his transbronchial lung biopsy specimen revealed mild interstitial fibrosis and mononuclear cell infiltration in alveolar walls without birefringent substances. However, widespread depositions of small glass fibers (< 2.5 microns in length and 0.3 micron in diameter) were detected by analytical electron microscopy, which suggested their possible contribution to the development of his pulmonary fibrosis.

  14. To direct the Librarian of Congress to obtain a stained glass panel depicting the seal of the District of Columbia and install the panel among the stained glass panels depicting the seals of States which overlook the Main Reading Room of the Library of Congress Thomas Jefferson Building.

    THOMAS, 113th Congress

    Rep. Norton, Eleanor Holmes [D-DC-At Large

    2014-02-27

    House - 02/28/2014 Referred to the Subcommittee on Economic Development, Public Buildings and Emergency Management. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  15. Long range wetting transparency on top of layered metal dielectric substrates

    DTIC Science & Technology

    2015-11-20

    multi-layered stacks were deposited onto glass substrates ( silica -based Micro cover glass , 22mmx22mm from VWR (48366-067), index of refraction n...necessarily endorsed by the United States Government. Long-range wetting transparency on top of layered metal-dielectric substrates M. A...as far as ~100 nm beneath the water/MgF2 interface. We refer to this phenomenon as long range wetting transparency . The latter effect cannot be

  16. Dielectric spectroscopy for the determination of the glass transition temperature of pharmaceutical solid dispersions.

    PubMed

    O'Donnell, Kevin P; Woodward, W H Hunter

    2015-06-01

    The purpose of this study was to evaluate analytical techniques for the measurement of the glass transition temperature of HPMC and formulated solid dispersions thereof. Unmodified samples of various grades of HPMC and solid dispersions of HPMC and itraconazole produced by hot melt extrusion were analyzed by thermomechanical analysis, differential scanning calorimetry, thermally stimulated depolarization current and dielectric spectroscopy. It was found that dielectric spectroscopy offers the best accuracy and reproducibility for analysis of the base HPMC powders regardless of the substitution type or viscosity grade and that the obtained results were not frequency dependent. The results of dielectric measurements of solid dispersions prepared by hot melt extrusion were compared with predicted values of the Gordon-Taylor equation. It was found that time-temperature superposition effects and small molecule frequency dependence makes broadly applying determination of the glass transition temperature in drug dispersions by dielectric spectroscopy prohibitively difficult.

  17. The behavior of silicon and boron in the surface of corroded nuclear waste glasses : an EFTEM study.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buck, E. C.; Smith, K. L.; Blackford, M. G.

    1999-11-23

    Using electron energy-loss filtered transmission electron microscopy (EFTEM), we have observed the formation of silicon-rich zones on the corroded surface of a West Valley (WV6) glass. This layer is approximately 100-200 nm thick and is directly underneath a precipitated smectite clay layer. Under conventional (C)TEM illumination, this layer is invisible; indeed, more commonly used analytical techniques, such as x-ray energy dispersive spectroscopy (EDS), have failed to describe fully the localized changes in the boron and silicon contents across this region. Similar silicon-rich and boron-depleted zones were not found on corroded Savannah River Laboratory (SRL) borosilicate glasses, including SRL-EA and SRL-51,more » although they possessed similar-looking clay layers. This study demonstrates a new tool for examining the corroded surfaces of materials.« less

  18. Simulation and analysis of plasmonic sensor in NIR with fluoride glass and graphene layer

    NASA Astrophysics Data System (ADS)

    Pandey, Ankit Kumar; Sharma, Anuj K.

    2018-02-01

    A calcium fluoride (CaF2) prism based plasmonic biosensor with graphene layer is proposed in near infrared region (NIR) of operation. The stacking of multilayer graphene is considered with dielectric interlayer sandwiched between two graphene layers. Excellent optical properties of CaF2 glass and enhanced field at the graphene-analyte interface are intended to be exploited for proposed sensor structure in NIR spectral region. Performance parameters in terms of field enhancement at interface and figure of merit (FOM) are analyzed and compared with those of conventional SPR based sensor. It is demonstrated that the same sensor probe can also be used for gas sensing with nearly 3.5-4 times enhancement in FOM, compared with conventional sensor. The results show that CaF2 based SPR sensor provides much better sensitivity than that based on other glasses.

  19. Analytical and regression models of glass rod drawing process

    NASA Astrophysics Data System (ADS)

    Alekseeva, L. B.

    2018-03-01

    The process of drawing glass rods (light guides) is being studied. The parameters of the process affecting the quality of the light guide have been determined. To solve the problem, mathematical models based on general equations of continuum mechanics are used. The conditions for the stable flow of the drawing process have been found, which are determined by the stability of the motion of the glass mass in the formation zone to small uncontrolled perturbations. The sensitivity of the formation zone to perturbations of the drawing speed and viscosity is estimated. Experimental models of the drawing process, based on the regression analysis methods, have been obtained. These models make it possible to customize a specific production process to obtain light guides of the required quality. They allow one to find the optimum combination of process parameters in the chosen area and to determine the required accuracy of maintaining them at a specified level.

  20. Predicting Crystallization of Amorphous Drugs with Terahertz Spectroscopy.

    PubMed

    Sibik, Juraj; Löbmann, Korbinian; Rades, Thomas; Zeitler, J Axel

    2015-08-03

    There is a controversy about the extent to which the primary and secondary dielectric relaxations influence the crystallization of amorphous organic compounds below the glass transition temperature. Recent studies also point to the importance of fast molecular dynamics on picosecond-to-nanosecond time scales with respect to the glass stability. In the present study we provide terahertz spectroscopy evidence on the crystallization of amorphous naproxen well below its glass transition temperature and confirm the direct role of Johari-Goldstein (JG) secondary relaxation as a facilitator of the crystallization. We determine the onset temperature Tβ above which the JG relaxation contributes to the fast molecular dynamics and analytically quantify the level of this contribution. We then show there is a strong correlation between the increase in the fast molecular dynamics and onset of crystallization in several chosen amorphous drugs. We believe that this technique has immediate applications to quantify the stability of amorphous drug materials.

  1. Adherence to AHA Guidelines When Adapted for Augmented Reality Glasses for Assisted Pediatric Cardiopulmonary Resuscitation: A Randomized Controlled Trial.

    PubMed

    Siebert, Johan N; Ehrler, Frederic; Gervaix, Alain; Haddad, Kevin; Lacroix, Laurence; Schrurs, Philippe; Sahin, Ayhan; Lovis, Christian; Manzano, Sergio

    2017-05-29

    The American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) are nowadays recognized as the world's most authoritative resuscitation guidelines. Adherence to these guidelines optimizes the management of critically ill patients and increases their chances of survival after cardiac arrest. Despite their availability, suboptimal quality of CPR is still common. Currently, the median hospital survival rate after pediatric in-hospital cardiac arrest is 36%, whereas it falls below 10% for out-of-hospital cardiac arrest. Among emerging information technologies and devices able to support caregivers during resuscitation and increase adherence to AHA guidelines, augmented reality (AR) glasses have not yet been assessed. In order to assess their potential, we adapted AHA Pediatric Advanced Life Support (PALS) guidelines for AR glasses. The study aimed to determine whether adapting AHA guidelines for AR glasses increased adherence by reducing deviation and time to initiation of critical life-saving maneuvers during pediatric CPR when compared with the use of PALS pocket reference cards. We conducted a randomized controlled trial with two parallel groups of voluntary pediatric residents, comparing AR glasses to PALS pocket reference cards during a simulation-based pediatric cardiac arrest scenario-pulseless ventricular tachycardia (pVT). The primary outcome was the elapsed time in seconds in each allocation group, from onset of pVT to the first defibrillation attempt. Secondary outcomes were time elapsed to (1) initiation of chest compression, (2) subsequent defibrillation attempts, and (3) administration of drugs, as well as the time intervals between defibrillation attempts and drug doses, shock doses, and number of shocks. All these outcomes were assessed for deviation from AHA guidelines. Twenty residents were randomized into 2 groups. Time to first defibrillation attempt (mean: 146 s) and adherence to AHA guidelines in terms of time to other critical resuscitation endpoints and drug dose delivery were not improved using AR glasses. However, errors and deviations were significantly reduced in terms of defibrillation doses when compared with the use of the PALS pocket reference cards. In a total of 40 defibrillation attempts, residents not wearing AR glasses used wrong doses in 65% (26/40) of cases, including 21 shock overdoses >100 J, for a cumulative defibrillation dose of 18.7 Joules per kg. These errors were reduced by 53% (21/40, P<.001) and cumulative defibrillation dose by 37% (5.14/14, P=.001) with AR glasses. AR glasses did not decrease time to first defibrillation attempt and other critical resuscitation endpoints when compared with PALS pocket cards. However, they improved adherence and performance among residents in terms of administering the defibrillation doses set by AHA. ©Johan N Siebert, Frederic Ehrler, Alain Gervaix, Kevin Haddad, Laurence Lacroix, Philippe Schrurs, Ayhan Sahin, Christian Lovis, Sergio Manzano. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 29.05.2017.

  2. Shocked Quartz Aggregates of the Cretaceous-Tertiary Boundary at Colorado, USA

    NASA Astrophysics Data System (ADS)

    Miura, Y.; Okamoto, M.; Iancu, O. G.

    1993-07-01

    Shock-metamorphosed quartz (i.e., shocked quartz) at the Cretaceous-Tertiary boundary (K/T) at Colorado [1,2] reveals the following mineralogical data by X-ray diffractometry and high-resolution electron micrograph with energy- dispersive spectrometry. 1. Shocked quartz is not normal (perfect crystalline) quartz mineral but various quartz aggregates that show relatively low X-ray intensity (i.e., imperfect crystalline) and shock lamellae with crystalline quartz and amorphous glass [3]. 2. Analytical electron micrographs indicate that crystalline quartz silica with spotty dislocation features is included in dendritic amorphous glasses of potassium (K) feldspar composition. Various compositions of glassy materials are found in shocked quartz aggregates as matrix or alternate shock lamellae, which is important to estimate the target rock of impact. The composition of glassy matrix is dendritic K-feldspar in the K/T boundary at Clear Creak North (CCN), Colorado, whereas that in the Barringer Crater is quartz-rich composition from the target rock of sandstone (or some mixture with iron meteorite), and that in artificial impact rock [3] is dendritic silica composition. It is found in this study that shocked quartz aggregates from the CCN K/T boundary samples are supplied from quartz and K-feldspar-bearing target rock at impact event (Table 1). Table 1, which appears here in the hard copy, shows the compositions, texture, and origin of shocked quartz aggregates. References: [1] Alvarez L. W. et al. (1980) Science, 208, 1095-1107. [2] Izett G. (1989) GSA Spec. Pap. 249, 1-194. [3] Miura Y. (1991) Shock Waves, 1, 35-41, Springer-Verlag.

  3. Fracture Strength of Fused Silica From Photonic Signatures Around Collision Sites

    NASA Technical Reports Server (NTRS)

    Yost, William T.; Cramer, K Elliott

    2015-01-01

    Impact sites in glass affect its fracture strength. An analytical model that predicts fracture strength from grey-field polariscope (GFP) readings (photoelastic retardations) has been developed and reported in the literature. The model is suggestive that stress fields, resulting from impact damage, destablizes sites within the glass, which lead to pathways that cause strength degradation. Using data collected from fused silica specimens fabricated from outer window panes that were designed for the space shuttle, the model was tested against four categories of inflicted damage. The damage sites were cored from the window carcasses, examined with the GFP and broken using the ASTM Standard C1499-09 to measure the fracture strength. A correlation is made between the fracture strength and the photoelastic retardation measured at the damage site in each specimen. A least-squares fit is calculated. The results are compared with the predictions from the model. A plausible single-sided NDE damage site inspection method (a version of which is planned for glass inspection in the Orion Project) that relates photoelastic retardation in glass components to its fracture strength is presented.

  4. Determination of reference ranges for elements in human scalp hair.

    PubMed

    Druyan, M E; Bass, D; Puchyr, R; Urek, K; Quig, D; Harmon, E; Marquardt, W

    1998-06-01

    Expected values, reference ranges, or reference limits are necessary to enable clinicians to apply analytical chemical data in the delivery of health care. Determination of references ranges is not straightforward in terms of either selecting a reference population or performing statistical analysis. In light of logistical, scientific, and economic obstacles, it is understandable that clinical laboratories often combine approaches in developing health associated reference values. A laboratory may choose to: 1. Validate either reference ranges of other laboratories or published data from clinical research or both, through comparison of patients test data. 2. Base the laboratory's reference values on statistical analysis of results from specimens assayed by the clinical reference laboratory itself. 3. Adopt standards or recommendations of regulatory agencies and governmental bodies. 4. Initiate population studies to validate transferred reference ranges or to determine them anew. Effects of external contamination and anecdotal information from clinicians may be considered. The clinical utility of hair analysis is well accepted for some elements. For others, it remains in the realm of clinical investigation. This article elucidates an approach for establishment of reference ranges for elements in human scalp hair. Observed levels of analytes from hair specimens from both our laboratory's total patient population and from a physician-defined healthy American population have been evaluated. Examination of levels of elements often associated with toxicity serves to exemplify the process of determining reference ranges in hair. In addition the approach serves as a model for setting reference ranges for analytes in a variety of matrices.

  5. Advanced Doubling Adding Method for Radiative Transfer in Planetary Atmospheres

    NASA Astrophysics Data System (ADS)

    Liu, Quanhua; Weng, Fuzhong

    2006-12-01

    The doubling adding method (DA) is one of the most accurate tools for detailed multiple-scattering calculations. The principle of the method goes back to the nineteenth century in a problem dealing with reflection and transmission by glass plates. Since then the doubling adding method has been widely used as a reference tool for other radiative transfer models. The method has never been used in operational applications owing to tremendous demand on computational resources from the model. This study derives an analytical expression replacing the most complicated thermal source terms in the doubling adding method. The new development is called the advanced doubling adding (ADA) method. Thanks also to the efficiency of matrix and vector manipulations in FORTRAN 90/95, the advanced doubling adding method is about 60 times faster than the doubling adding method. The radiance (i.e., forward) computation code of ADA is easily translated into tangent linear and adjoint codes for radiance gradient calculations. The simplicity in forward and Jacobian computation codes is very useful for operational applications and for the consistency between the forward and adjoint calculations in satellite data assimilation.

  6. Capabilities and limitations of handheld Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for the analysis of colourants and binders in 20th-century reverse paintings on glass.

    PubMed

    Steger, Simon; Stege, Heike; Bretz, Simone; Hahn, Oliver

    2018-04-15

    A non-invasive method has been carried out to show the capabilities and limitations of Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) for identifying of colourants and binders in modern reverse glass paintings. For this purpose, the reverse glass paintings "Zwei Frauen am Tisch" (1920-22), "Bäume" (1946) (both by Heinrich Campendonk), "Lofoten" (1933) (Edith Campendonk-van Leckwyck) and "Ohne Titel" (1954) (Marianne Uhlenhuth), were measured. In contrast to other techniques (e.g. panel and mural painting), the paint layers are applied in reverse succession. In multi-layered paint systems, the front paint layer may no longer be accessible. The work points out the different spectral appearance of a given substance (gypsum, basic lead white) in reverse glass paintings. However, inverted bands, band overlapping and derivative-shaped spectral features can be interpreted by comparing the spectra from the paintings with spectra from pure powders and pigment/linseed oil mock-ups. Moreover, the work focuses on this method's capabilities in identifying synthetic organic pigments (SOP). Reference spectra of three common SOP (PG7, PY1, PR83) were obtained from powders and historical colour charts. We identified PR83 and PY1 in two reverse glass paintings, using the measured reference spectra. The recorded DRIFTS spectra of pure linseed oil, gum Arabic, mastic, polyvinyl acetate resin and bees wax can be used to classify the binding media of the measured paintings. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. A Magnifying Glass for Virtual Imaging of Subwavelength Resolution by Transformation Optics.

    PubMed

    Sun, Fei; Guo, Shuwei; Liu, Yichao; He, Sailing

    2018-06-14

    Traditional magnifying glasses can give magnified virtual images with diffraction-limited resolution, that is, detailed information is lost. Here, a novel magnifying glass by transformation optics, referred to as a "superresolution magnifying glass" (SMG) is designed, which can produce magnified virtual images with a predetermined magnification factor and resolve subwavelength details (i.e., light sources with subwavelength distances can be resolved). Based on theoretical calculations and reductions, a metallic plate structure to produce the reduced SMG in microwave frequencies, which gives good performance verified by both numerical simulations and experimental results, is proposed and realized. The function of SMG is to create a superresolution virtual image, unlike traditional superresolution imaging devices that create real images. The proposed SMG will create a new branch of superresolution imaging technology. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Establishment of a reference collection of additives and an analytical handbook of reference data to support enforcement of EU regulations on food contact plastics.

    PubMed

    van Lierop, B; Castle, L; Feigenbaum, A; Ehlert, K; Boenke, A

    1998-10-01

    A collection has been made of additives that are required as analytical standards for enforcement of European Union legislation on food contact plastics. The 100 additives have been characterized by mass spectrometry, infra-red spectroscopy and proton nuclear magnetic resonance spectroscopy to provide reference spectra. Gas chromatographic retention times have been recorded to facilitate identification by retention index. This information has been further supplemented by physico-chemical data. Finally, chromatographic methods have been used to indicate the presence of any impurities in the commercial chemicals. Samples of the reference substances are available on request and the collection of spectra and other information will be made available in printed format and on-line through the Internet. This paper gives an overview of the work done to establish the reference collection and the spectral atlas, which together will assist enforcement laboratories in the characterization of plastics and the selection of analytical methods for additives that may migrate.

  9. Reflections on Refraction.

    ERIC Educational Resources Information Center

    Iona, Mario; Beaty, William J.

    1988-01-01

    Presents two views about lenses and optics in attempt to clarify a story written by Carolyn Hermann, "Through the Magnifying Glass." Cites two references for additional reading on students' optics difficulties. (RT)

  10. Bismuth silicate glass containing heavy metal oxide as a promising radiation shielding material

    NASA Astrophysics Data System (ADS)

    Elalaily, Nagia A.; Abou-Hussien, Eman M.; Saad, Ebtisam A.

    2016-12-01

    Optical and FTIR spectroscopic measurements and electron paramagnetic resonance (EPR) properties have been utilized to investigate and characterize the given compositions of binary bismuth silicate glasses. In this work, it is aimed to study the possibility of using the prepared bismuth silicate glasses as a good shielding material for γ-rays in which adding bismuth oxide to silicate glasses causes distinguish increase in its density by an order of magnitude ranging from one to two more than mono divalent oxides. The good thermal stability and high density of the bismuth-based silicate glass encourage many studies to be undertaken to understand its radiation shielding efficiency. For this purpose a glass containing 20% bismuth oxide and 80% SiO2 was prepared using the melting-annealing technique. In addition the effects of adding some alkali heavy metal oxides to this glass, such as PbO, BaO or SrO, were also studied. EPR measurements show that the prepared glasses have good stability when exposed to γ-irradiation. The changes in the FTIR spectra due to the presence of metal oxides were referred to the different housing positions and physical properties of the respective divalent Sr2+, Ba2+ and Pb2+ ions. Calculations of optical band gap energies were presented for some selected glasses from the UV data to support the probability of using these glasses as a gamma radiation shielding material. The results showed stability of both optical and magnetic spectra of the studied glasses toward gamma irradiation, which validates their irradiation shielding behavior and suitability as the radiation shielding candidate materials.

  11. 76 FR 15974 - Office of Research and Development; Ambient Air Monitoring Reference and Equivalent Methods...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-22

    ... on a particle filter. Because this new measurement approach is being approved for NAAQS compliance... Lead (Pb) on TSP High-Volume Filters.'' A sample of total suspended particulate matter (TSP) is collected on a glass fiber filter, using the sampler and procedure of the EPA Reference Method for the...

  12. Factors That Attenuate the Correlation Coefficient and Its Analogs.

    ERIC Educational Resources Information Center

    Dolenz, Beverly

    The correlation coefficient is an integral part of many other statistical techniques (analysis of variance, t-tests, etc.), since all analytic methods are actually correlational (G. V. Glass and K. D. Hopkins, 1984). The correlation coefficient is a statistical summary that represents the degree and direction of relationship between two variables.…

  13. Computer-Based Instruction and Health Professions Education: A Meta-Analysis of Outcomes.

    ERIC Educational Resources Information Center

    Cohen, Peter A.; Dacanay, Lakshmi S.

    1992-01-01

    The meta-analytic techniques of G. V. Glass were used to statistically integrate findings from 47 comparative studies on computer-based instruction (CBI) in health professions education. A clear majority of the studies favored CBI over conventional methods of instruction. Results show higher-order applications of computers to be especially…

  14. 21 CFR 172.864 - Synthetic fatty alcohols.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing. n... specifications prescribed in paragraph (a)(1) (i) and (iii) of this section. (3) n-Octyl; manufactured by the... produce n-octyl alcohol with a minimum purity of 99 percent. The analytical method for n-octyl alcohol...

  15. 21 CFR 172.864 - Synthetic fatty alcohols.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing. n... specifications prescribed in paragraph (a)(1) (i) and (iii) of this section. (3) n-Octyl; manufactured by the... produce n-octyl alcohol with a minimum purity of 99 percent. The analytical method for n-octyl alcohol...

  16. 21 CFR 172.864 - Synthetic fatty alcohols.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing. n... specifications prescribed in paragraph (a)(1) (i) and (iii) of this section. (3) n-Octyl; manufactured by the... produce n-octyl alcohol with a minimum purity of 99 percent. The analytical method for n-octyl alcohol...

  17. Compression failure mechanisms of composite structures

    NASA Technical Reports Server (NTRS)

    Hahn, H. T.; Sohi, M.; Moon, S.

    1986-01-01

    An experimental and analytical study was conducted to delineate the compression failure mechanisms of composite structures. The present report summarizes further results on kink band formation in unidirectional composites. In order to assess the compressive strengths and failure modes of fibers them selves, a fiber bundle was embedded in epoxy casting and tested in compression. A total of six different fibers were used together with two resins of different stiffnesses. The failure of highly anisotropic fibers such as Kevlar 49 and P-75 graphite was due to kinking of fibrils. However, the remaining fibers--T300 and T700 graphite, E-glass, and alumina--failed by localized microbuckling. Compressive strengths of the latter group of fibers were not fully utilized in their respective composite. In addition, acoustic emission monitoring revealed that fiber-matrix debonding did not occur gradually but suddenly at final failure. The kink band formation in unidirectional composites under compression was studied analytically and through microscopy. The material combinations selected include seven graphite/epoxy composites, two graphite/thermoplastic resin composites, one Kevlar 49/epoxy composite and one S-glass/epoxy composite.

  18. Establishment of reference intervals of clinical chemistry analytes for the adult population in Saudi Arabia: a study conducted as a part of the IFCC global study on reference values.

    PubMed

    Borai, Anwar; Ichihara, Kiyoshi; Al Masaud, Abdulaziz; Tamimi, Waleed; Bahijri, Suhad; Armbuster, David; Bawazeer, Ali; Nawajha, Mustafa; Otaibi, Nawaf; Khalil, Haitham; Kawano, Reo; Kaddam, Ibrahim; Abdelaal, Mohamed

    2016-05-01

    This study is a part of the IFCC-global study to derive reference intervals (RIs) for 28 chemistry analytes in Saudis. Healthy individuals (n=826) aged ≥18 years were recruited using the global study protocol. All specimens were measured using an Architect analyzer. RIs were derived by both parametric and non-parametric methods for comparative purpose. The need for secondary exclusion of reference values based on latent abnormal values exclusion (LAVE) method was examined. The magnitude of variation attributable to gender, ages and regions was calculated by the standard deviation ratio (SDR). Sources of variations: age, BMI, physical exercise and smoking levels were investigated by using the multiple regression analysis. SDRs for gender, age and regional differences were significant for 14, 8 and 2 analytes, respectively. BMI-related changes in test results were noted conspicuously for CRP. For some metabolic related parameters the ranges of RIs by non-parametric method were wider than by the parametric method and RIs derived using the LAVE method were significantly different than those without it. RIs were derived with and without gender partition (BMI, drugs and supplements were considered). RIs applicable to Saudis were established for the majority of chemistry analytes, whereas gender, regional and age RI partitioning was required for some analytes. The elevated upper limits of metabolic analytes reflects the existence of high prevalence of metabolic syndrome in Saudi population.

  19. Establishing pediatric reference intervals for 13 biochemical analytes derived from normal subjects in a pediatric endocrinology clinic in Korea.

    PubMed

    Cho, Sun-Mi; Lee, Sang-Guk; Kim, Ho Seong; Kim, Jeong-Ho

    2014-12-01

    Defining pediatric reference intervals is one of the most difficult tasks for laboratory physicians. The continuously changing physiology of growing children makes their laboratory values moving targets. In addition, ethnic and behavioral differences might also cause variations. The aim of this study was to establish age- and sex-specific partitioned reference intervals for 13 serum biochemical analytes in Korean children. A total of 2474 patients, girls aged 2-14 years and boys aged 2-16 years, who underwent a short stature workup but were diagnosed as normal at the Pediatric Endocrinology Clinic of Severance Hospital (Seoul, Korea) between September 2010 and June 2012 were included in this study. The levels of serum calcium, inorganic phosphorus, blood urea nitrogen, creatinine, uric acid, glucose, total cholesterol, total protein, albumin, alkaline phosphatase, aspartic aminotransferase, alanine aminotransferase, and total bilirubin were measured using a Hitachi 7600 analyzer (Hitachi High-Technologies Corporation, Tokyo, Japan). Reference intervals were partitioned according to sex or age subgroups using the Harris and Boyd method. Most analytes except calcium and albumin required partitioning either by sex or age. Age-specific partitioned reference intervals for alkaline phosphatase, creatinine, and total bilirubin were established for both males and females after being partitioned by sex. Additional age-specific partitioning of aspartic aminotransferase in females and total protein and uric acid in males was also required. Inorganic phosphorus, total cholesterol, alanine aminotransferase, blood urea nitrogen, and glucose were partitioned only by sex. This study provided updated age- and sex-specific pediatric reference intervals for 13 basic serum chemistry analytes from a sufficient number of healthy children by using a modern analytical chemistry platform. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Photolithography-free laser-patterned HF acid-resistant chromium-polyimide mask for rapid fabrication of microfluidic systems in glass

    NASA Astrophysics Data System (ADS)

    Zamuruyev, Konstantin O.; Zrodnikov, Yuriy; Davis, Cristina E.

    2017-01-01

    Excellent chemical and physical properties of glass, over a range of operating conditions, make it a preferred material for chemical detection systems in analytical chemistry, biology, and the environmental sciences. However, it is often compromised with SU8, PDMS, or Parylene materials due to the sophisticated mask preparation requirements for wet etching of glass. Here, we report our efforts toward developing a photolithography-free laser-patterned hydrofluoric acid-resistant chromium-polyimide tape mask for rapid prototyping of microfluidic systems in glass. The patterns are defined in masking layer with a diode-pumped solid-state laser. Minimum feature size is limited to the diameter of the laser beam, 30 µm minimum spacing between features is limited by the thermal shrinkage and adhesive contact of the polyimide tape to 40 µm. The patterned glass substrates are etched in 49% hydrofluoric acid at ambient temperature with soft agitation (in time increments, up to 60 min duration). In spite of the simplicity, our method demonstrates comparable results to the other current more sophisticated masking methods in terms of the etched depth (up to 300 µm in borosilicate glass), feature under etch ratio in isotropic etch (~1.36), and low mask hole density. The method demonstrates high yield and reliability. To our knowledge, this method is the first proposed technique for rapid prototyping of microfluidic systems in glass with such high performance parameters. The proposed method of fabrication can potentially be implemented in research institutions without access to a standard clean-room facility.

  2. Comparison of analytical and predictive methods for water, protein, fat, sugar, and gross energy in marine mammal milk.

    PubMed

    Oftedal, O T; Eisert, R; Barrell, G K

    2014-01-01

    Mammalian milks may differ greatly in composition from cow milk, and these differences may affect the performance of analytical methods. High-fat, high-protein milks with a preponderance of oligosaccharides, such as those produced by many marine mammals, present a particular challenge. We compared the performance of several methods against reference procedures using Weddell seal (Leptonychotes weddellii) milk of highly varied composition (by reference methods: 27-63% water, 24-62% fat, 8-12% crude protein, 0.5-1.8% sugar). A microdrying step preparatory to carbon-hydrogen-nitrogen (CHN) gas analysis slightly underestimated water content and had a higher repeatability relative standard deviation (RSDr) than did reference oven drying at 100°C. Compared with a reference macro-Kjeldahl protein procedure, the CHN (or Dumas) combustion method had a somewhat higher RSDr (1.56 vs. 0.60%) but correlation between methods was high (0.992), means were not different (CHN: 17.2±0.46% dry matter basis; Kjeldahl 17.3±0.49% dry matter basis), there were no significant proportional or constant errors, and predictive performance was high. A carbon stoichiometric procedure based on CHN analysis failed to adequately predict fat (reference: Röse-Gottlieb method) or total sugar (reference: phenol-sulfuric acid method). Gross energy content, calculated from energetic factors and results from reference methods for fat, protein, and total sugar, accurately predicted gross energy as measured by bomb calorimetry. We conclude that the CHN (Dumas) combustion method and calculation of gross energy are acceptable analytical approaches for marine mammal milk, but fat and sugar require separate analysis by appropriate analytic methods and cannot be adequately estimated by carbon stoichiometry. Some other alternative methods-low-temperature drying for water determination; Bradford, Lowry, and biuret methods for protein; the Folch and the Bligh and Dyer methods for fat; and enzymatic and reducing sugar methods for total sugar-appear likely to produce substantial error in marine mammal milks. It is important that alternative analytical methods be properly validated against a reference method before being used, especially for mammalian milks that differ greatly from cow milk in analyte characteristics and concentrations. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Stress Mapping in Glass-to-Metal Seals using Indentation Crack Lengths.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strong, Kevin; Buchheit, Thomas E.; Diebold, Thomas Wayne

    Predicting the residual stress which develops during fabrication of a glass-to-metal compression seal requires material models that can accurately predict the effects of processing on the sealing glass. Validation of the predictions requires measurements on representative test geometries to accurately capture the interaction between the seal materials during a processing cycle required to form the seal, which consists of a temperature excursion through the glass transition temperature of the sealing glass. To this end, a concentric seal test geometry, referred to as a short cylinder seal, consisting of a stainless steel shell enveloping a commercial sealing glass disk has beenmore » designed, fabricated, and characterized as a model validation test geometry. To obtain data to test/validate finite element (FE) stress model predictions of this geometry, spatially-resolved residual stress was calculated from the measured lengths of the cracks emanating from radially positioned Vickers indents in the glass disk portion of the seal. The indentation crack length method is described, and the spatially-resolved residual stress determined experimentally are compared to FE stress predictions made using a nonlinear viscoelastic material model adapted to inorganic sealing glasses and an updated rate dependent material model for 304L stainless steel. The measurement method is a first to achieve a degree of success for measuring spatially resolved residual stress in a glass-bearing geometry and a favorable comparison between measurements and simulation was observed.« less

  4. Stress Mapping in Glass-to-Metal Seals using Indentation Crack Lengths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buchheit, Thomas E.; Strong, Kevin; Newton, Clay S.

    Predicting the residual stress which develops during fabrication of a glass-to-metal compression seal requires material models that can accurately predict the effects of processing on the sealing glass. Validation of the predictions requires measurements on representative test geometries to accurately capture the interaction between the seal materials during a processing cycle required to form the seal, which consists of a temperature excursion through the glass transition temperature of the sealing glass. To this end, a concentric seal test geometry, referred to as a short cylinder seal, consisting of a stainless steel shell enveloping a commercial sealing glass disk has beenmore » designed, fabricated, and characterized as a model validation test geometry. To obtain data to test/validate finite element (FE) stress model predictions of this geometry, spatially-resolved residual stress was calculated from the measured lengths of the cracks emanating from radially positioned Vickers indents in the glass disk portion of the seal. The indentation crack length method is described, and the spatially-resolved residual stress determined experimentally are compared to FE stress predictions made using a nonlinear viscoelastic material model adapted to inorganic sealing glasses and an updated rate dependent material model for 304L stainless steel. The measurement method is a first to achieve a degree of success for measuring spatially resolved residual stress in a glass-bearing geometry and a favorable comparison between measurements and simulation was observed.« less

  5. Gallium-containing phospho-silicate glasses: synthesis and in vitro bioactivity.

    PubMed

    Franchini, Mirco; Lusvardi, Gigliola; Malavasi, Gianluca; Menabue, Ledi

    2012-08-01

    A series of Ga-containing phospho-silicate glasses based on Bioglass 45S5, having molar formula 46.2SiO2·24.3Na2O·26.9CaO·2.6P2O5·xGa2O3 (x=1.0, 1.6, 3.5), were prepared by fusion method. The reference Bioglass 45S5 without gallium was also prepared. The synthesized glasses were immersed in simulated body fluid (SBF) for 30 days in order to observe ion release and hydroxyapatite (HA) formation. All Ga-containing glasses maintain the ability of HA formation as indicated by main X-ray diffractometric peaks and/or electronic scanning microscopy results. HA layer was formed after 1 day of SBF soaking in 45S5 glass containing up to 1.6% Ga2O3 content. Moreover, gallium released by the glasses was found to be partially precipitated on the glass surface as gallium phosphate. Further increase in gallium content reduced the ion release in SBF. The maximum of Ga(3+) concentration measured in solution is ~6 ppm determined for 3.5% Ga2O3 content. This amount is about half of the toxic level (14 ppm) of gallium and the glasses release gallium till 30 days of immersion in SBF. Considering the above results, the studied materials can be proposed as bioactive glasses with additional antimicrobial effect of gallium having no toxic outcome. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Can a glass cockpit display help (or hinder) performance of novices in simulated flight training?

    PubMed

    Wright, Stephen; O'Hare, David

    2015-03-01

    The analog dials in traditional GA aircraft cockpits are being replaced by integrated electronic displays, commonly referred to as glass cockpits. Pilots may be trained on glass cockpit aircraft or encounter them after training on traditional displays. The effects of glass cockpit displays on initial performance and potential transfer effects between cockpit display configurations have yet to be adequately investigated. Flight-naïve participants were trained on either a simulated traditional display cockpit or a simulated glass display cockpit. Flight performance was measured in a test flight using either the same or different cockpit display. Loss of control events and accuracy in controlling altitude, airspeed and heading, workload, and situational awareness were assessed. Preferences for cockpit display configurations and opinions on ease of use were also measured. The results revealed consistently poorer performance on the test flight for participants using the glass cockpit compared to the traditional cockpit. In contrast the post-flight questionnaire data revealed a strong subjective preference for the glass cockpit over the traditional cockpit displays. There was only a weak effect of prior training. The specific glass cockpit display used in this study was subjectively appealing but yielded poorer flight performance in participants with no previous flight experience than a traditional display. Performance data can contradict opinion data. The design of glass cockpit displays may present some difficulties for pilots in the very early stages of training. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  7. Exploration of a new method in determining the glass transition temperature of BMGs by electrical resistivity

    NASA Astrophysics Data System (ADS)

    Guo, Jing; Zu, Fangqiu; Chen, Zhihao; Zheng, Shubin; Yuan, Yuan

    2005-07-01

    Based on a brief retrospect of the method in establishing Tg of the bulk metallic glasses (BMGs), some perplexities concerning this are pointed out. With the experimental results of Zr-Al-Ni-Cu-X (Nb,Ti) BMGs, a electrical resistivity method is proposed to determine the glass transition temperature of BMGs. With the method, we define two kinds of characteristic temperature related to the glass transition, Tg-dep and Tg-int, respectively. By comparing Tg-dep and Tg-int with Tg determined by the DSC method, we have found that, for the same alloy at the same heating rate, Tg-dep is very close to Tg-onset while Tg-int is approximate to Tg-mid. As a method to determine the glass transition temperature, the electrical resistivity method has proved to be more convenient and practical in comparison with the DSC method, especially when the DSC curve cannot show the glass transition character of BMGs. In addition, we would emphasize that when we refer to Tg, it is necessary to expatiate on the way of denoting the glass transition temperature, such as Tg-dep or Tg-int ( Tg-onset or Tg-mid), and on the heating rate, in order to avoid ambiguity.

  8. Rediscovering ancient glass technologies through the examination of opacifier crystals

    NASA Astrophysics Data System (ADS)

    Lahlil, S.; Biron, I.; Galoisy, L.; Morin, G.

    2008-07-01

    The aim of the study is to understand how antimonate opacifying crystals were obtained throughout history. Two archaeological glass productions opacified with calcium and lead antimonates are studied in this paper, in order to rediscover ancient opaque glass technologies: Roman mosaic tesserae (1st cent. B.C. 4th cent. A.D.) and Nevers lampworking glass (18th cent. A.D.). The fine examination of crystalline phases and of the vitreous matrix is undertaken using various and complementary techniques. Results are compared with a modern reference production, for which the technological process is well known. We demonstrate that Ca-antimonate opacifiers in Roman mosaic tesserae, as well as in Nevers lampworking glass, were obtained by in situ crystallization. Nevertheless, Roman and Nevers glass would have undergone different firing processes. We propose that the addition of previously synthesized crystals or the use of “anime” could be the process used to obtain Pb-antimonate opacified glass, for both productions studied. We demonstrate that CaO, PbO and Sb2O3 concentrations in the bulk compositions and in the matrices, and their evolution with the crystallinity ratio, offer robust criteria for the distinction of the opacification process used. Also, the different crystalline structures help to provide information on the experimental conditions.

  9. Separation of very hydrophobic analytes by micellar electrokinetic chromatography IV. Modeling of the effective electrophoretic mobility from carbon number equivalents and octanol-water partition coefficients.

    PubMed

    Huhn, Carolin; Pyell, Ute

    2008-07-11

    It is investigated whether those relationships derived within an optimization scheme developed previously to optimize separations in micellar electrokinetic chromatography can be used to model effective electrophoretic mobilities of analytes strongly differing in their properties (polarity and type of interaction with the pseudostationary phase). The modeling is based on two parameter sets: (i) carbon number equivalents or octanol-water partition coefficients as analyte descriptors and (ii) four coefficients describing properties of the separation electrolyte (based on retention data for a homologous series of alkyl phenyl ketones used as reference analytes). The applicability of the proposed model is validated comparing experimental and calculated effective electrophoretic mobilities. The results demonstrate that the model can effectively be used to predict effective electrophoretic mobilities of neutral analytes from the determined carbon number equivalents or from octanol-water partition coefficients provided that the solvation parameters of the analytes of interest are similar to those of the reference analytes.

  10. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water.

    PubMed

    Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B

    2014-10-15

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

  11. Iron metal production in silicate melts through the direct reduction of Fe/II/ by Ti/III/, Cr/II/, and Eu/II/. [in lunar basalts

    NASA Technical Reports Server (NTRS)

    Schreiber, H. D.; Balazs, G. B.; Shaffer, A. P.; Jamison, P. L.

    1982-01-01

    The production of metallic iron in silicate melts by chemical reactions of Ti(3+), Cr(2+), and Eu(2+) with Fe(2+) is demonstrated under experimental conditions in a simplified basaltic liquid. These reactions form a basis for interpreting the role of isochemical valency exchange models in explanations for the reduced nature of lunar basalts. The redox couples are individually investigated in the silicate melt to ascertain reference redox ratios that are independent of mutual interactions. These studies also provide calibrations of spectral absorptions of the Fe(2+) and Ti(2+) species in these glasses. Subsequent spectrophotometric analyses of Fe(2+) and Ti(2+) in glasses doped with both iron and titanium and of Fe(2+) in glasses doped with either iron and chromium or iron and europium ascertain the degree of mutual interactions in these dual-doped glasses.

  12. Modelisation of the SECMin molten salts environment

    NASA Astrophysics Data System (ADS)

    Lucas, M.; Slim, C.; Delpech, S.; di Caprio, D.; Stafiej, J.

    2014-06-01

    We develop a cellular automata modelisation of SECM experiments to study corrosion in molten salt media for generation IV nuclear reactors. The electrodes used in these experiments are cylindrical glass tips with a coaxial metal wire inside. As the result of simulations we obtain the current approach curves of the electrodes with geometries characterized by several values of the ratios of glass to metal area at the tip. We compare these results with predictions of the known analytic expressions, solutions of partial differential equations for flat uniform geometry of the substrate. We present the results for other, more complicated substrate surface geometries e. g. regular saw modulated surface, surface obtained by Eden model process, ...

  13. A multicenter nationwide reference intervals study for common biochemical analytes in Turkey using Abbott analyzers.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Aslan, Diler; Aybek, Hulya; Ari, Zeki; Taneli, Fatma; Coker, Canan; Akan, Pinar; Sisman, Ali Riza; Bahceci, Onur; Sezgin, Nurzen; Demir, Meltem; Yucel, Gultekin; Akbas, Halide; Ozdem, Sebahat; Polat, Gurbuz; Erbagci, Ayse Binnur; Orkmez, Mustafa; Mete, Nuriye; Evliyaoglu, Osman; Kiyici, Aysel; Vatansev, Husamettin; Ozturk, Bahadir; Yucel, Dogan; Kayaalp, Damla; Dogan, Kubra; Pinar, Asli; Gurbilek, Mehmet; Cetinkaya, Cigdem Damla; Akin, Okhan; Serdar, Muhittin; Kurt, Ismail; Erdinc, Selda; Kadicesme, Ozgur; Ilhan, Necip; Atali, Dilek Sadak; Bakan, Ebubekir; Polat, Harun; Noyan, Tevfik; Can, Murat; Bedir, Abdulkerim; Okuyucu, Ali; Deger, Orhan; Agac, Suret; Ademoglu, Evin; Kaya, Ayşem; Nogay, Turkan; Eren, Nezaket; Dirican, Melahat; Tuncer, GulOzlem; Aykus, Mehmet; Gunes, Yeliz; Ozmen, Sevda Unalli; Kawano, Reo; Tezcan, Sehavet; Demirpence, Ozlem; Degirmen, Elif

    2014-12-01

    A nationwide multicenter study was organized to establish reference intervals (RIs) in the Turkish population for 25 commonly tested biochemical analytes and to explore sources of variation in reference values, including regionality. Blood samples were collected nationwide in 28 laboratories from the seven regions (≥400 samples/region, 3066 in all). The sera were collectively analyzed in Uludag University in Bursa using Abbott reagents and analyzer. Reference materials were used for standardization of test results. After secondary exclusion using the latent abnormal values exclusion method, RIs were derived by a parametric method employing the modified Box-Cox formula and compared with the RIs by the non-parametric method. Three-level nested ANOVA was used to evaluate variations among sexes, ages and regions. Associations between test results and age, body mass index (BMI) and region were determined by multiple regression analysis (MRA). By ANOVA, differences of reference values among seven regions were significant in none of the 25 analytes. Significant sex-related and age-related differences were observed for 10 and seven analytes, respectively. MRA revealed BMI-related changes in results for uric acid, glucose, triglycerides, high-density lipoprotein (HDL)-cholesterol, alanine aminotransferase, and γ-glutamyltransferase. Their RIs were thus derived by applying stricter criteria excluding individuals with BMI >28 kg/m2. Ranges of RIs by non-parametric method were wider than those by parametric method especially for those analytes affected by BMI. With the lack of regional differences and the well-standardized status of test results, the RIs derived from this nationwide study can be used for the entire Turkish population.

  14. Multiscale Modeling of Non-crystalline Ceramics (Glass)

    DTIC Science & Technology

    2011-02-01

    4). 5.3 Approach: We will produce high silica glasses with additions of up to 10 wt% of network formers and modifiers using Momentive’s lab scale...Aij , rij , ρ, and Cij are constants, which are provided by van Beest et al. (16); we refer to equation 2 as the BKS potential. 7.2 Generating...Optischer und Elektrostatischer Gitterpotentiale. Ann. Phys. 1921, 369, 253–287. 16. van Beest , B. W. H.; Kramer, G. J.; van Santen, R. A. Force-fields for

  15. The shear modulus of metastable amorphous solids with strong central and bond-bending interactions

    NASA Astrophysics Data System (ADS)

    Zaccone, Alessio

    2009-07-01

    We derive expressions for the shear modulus of deeply quenched, glassy solids, in terms of a Cauchy-Born free energy expansion around a rigid (quenched) reference state, following the approach due to Alexander (1998 Phys. Rep. 296 65). Continuum-limit explicit expressions of the shear modulus are derived starting from the microscopic Hamiltonians of central and bond-bending interactions. The applicability of the expressions to dense covalent glasses as well as colloidal glasses involving strongly attractive or adhesive bonds is discussed.

  16. Composite material bend-twist coupling for wind turbine blade applications

    NASA Astrophysics Data System (ADS)

    Walsh, Justin M.

    Current efforts in wind turbine blade design seek to employ bend-twist coupling of composite materials for passive power control by twisting blades to feather. Past efforts in this area of study have proved to be problematic, especially in formulation of the bend-twist coupling coefficient alpha. Kevlar/epoxy, carbon/epoxy and glass/epoxy specimens were manufactured to study bend-twist coupling, from which numerical and analytical models could be verified. Finite element analysis was implemented to evaluate fiber orientation and material property effects on coupling magnitude. An analytical/empirical model was then derived to describe numerical results and serve as a replacement for the commonly used coupling coefficient alpha. Through the results from numerical and analytical models, a foundation for aeroelastic design of wind turbines blades utilizing biased composite materials is provided.

  17. Immediacy, Emotion, and the Filling of Glasses: Next Round's on You

    ERIC Educational Resources Information Center

    Heinrichs, R. Walter

    2006-01-01

    In this article, I respond to comments made by K. Salzinger and A. Aleman and A. S. David on my original article. The constructive, reconstructive, and interpretive nature of human cognition is well illustrated by these two responses to my recent article on schizophrenia. In the original article, I used meta-analytic summaries of the published…

  18. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  19. 'Aussie normals': an a priori study to develop clinical chemistry reference intervals in a healthy Australian population.

    PubMed

    Koerbin, G; Cavanaugh, J A; Potter, J M; Abhayaratna, W P; West, N P; Glasgow, N; Hawkins, C; Armbruster, D; Oakman, C; Hickman, P E

    2015-02-01

    Development of reference intervals is difficult, time consuming, expensive and beyond the scope of most laboratories. The Aussie Normals study is a direct a priori study to determine reference intervals in healthy Australian adults. All volunteers completed a health and lifestyle questionnaire and exclusion was based on conditions such as pregnancy, diabetes, renal or cardiovascular disease. Up to 91 biochemical analyses were undertaken on a variety of analytical platforms using serum samples collected from 1856 volunteers. We report on our findings for 40 of these analytes and two calculated parameters performed on the Abbott ARCHITECTci8200/ci16200 analysers. Not all samples were analysed for all assays due to volume requirements or assay/instrument availability. Results with elevated interference indices and those deemed unsuitable after clinical evaluation were removed from the database. Reference intervals were partitioned based on the method of Harris and Boyd into three scenarios, combined gender, males and females and age and gender. We have performed a detailed reference interval study on a healthy Australian population considering the effects of sex, age and body mass. These reference intervals may be adapted to other manufacturer's analytical methods using method transference.

  20. Evaluation of an in-practice wet-chemistry analyzer using canine and feline serum samples.

    PubMed

    Irvine, Katherine L; Burt, Kay; Papasouliotis, Kostas

    2016-01-01

    A wet-chemistry biochemical analyzer was assessed for in-practice veterinary use. Its small size may mean a cost-effective method for low-throughput in-house biochemical analyses for first-opinion practice. The objectives of our study were to determine imprecision, total observed error, and acceptability of the analyzer for measurement of common canine and feline serum analytes, and to compare clinical sample results to those from a commercial reference analyzer. Imprecision was determined by within- and between-run repeatability for canine and feline pooled samples, and manufacturer-supplied quality control material (QCM). Total observed error (TEobs) was determined for pooled samples and QCM. Performance was assessed for canine and feline pooled samples by sigma metric determination. Agreement and errors between the in-practice and reference analyzers were determined for canine and feline clinical samples by Bland-Altman and Deming regression analyses. Within- and between-run precision was high for most analytes, and TEobs(%) was mostly lower than total allowable error. Performance based on sigma metrics was good (σ > 4) for many analytes and marginal (σ > 3) for most of the remainder. Correlation between the analyzers was very high for most canine analytes and high for most feline analytes. Between-analyzer bias was generally attributed to high constant error. The in-practice analyzer showed good overall performance, with only calcium and phosphate analyses identified as significantly problematic. Agreement for most analytes was insufficient for transposition of reference intervals, and we recommend that in-practice-specific reference intervals be established in the laboratory. © 2015 The Author(s).

  1. Development of a reference material for routine performance monitoring of methods measuring polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and dioxin-like polychlorinated biphenyls.

    PubMed

    Selliah, S S; Cussion, S; MacPherson, K A; Reiner, E J; Toner, D

    2001-06-01

    Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.

  2. VNIR reflectance spectroscopy of glassy igneous material with variable oxidation states

    NASA Astrophysics Data System (ADS)

    Carli, Cristian; Di Genova, Danilo; Roush, Ted L.; Ertel-Ingrisch, Werner; Capaccioni, Fabrizio; Dingwell, Donald B.

    2017-04-01

    Silicate glasses with igneous compositions may represent an abundant component of planetary surface material via effusive volcanism or impact cratering processes. Several planetary surfaces are mapped with hyper-spectrometers in the visible and near-infrared (VNIR). In this spectral range, crystal field (C.F.) absorptions are useful to discriminate iron-bearing silicate components. At the same time, in the VNIR reflectance spectroscopy iron bearing glasses may exhibit a C.F. absorption at ˜1.1 μm. A weak C.F. absorption is also present at ˜1.9 μm. These absorptions can be therefore diagnostic for glassy component and can also affect the C.F. absorptions of mafic minerals when mixed in the regolith. So far, few studies investigated the spectral properties of systematic glasses compositions and at different oxygen fucacity. For these reasons studying glassy materials, and their optical constants, represents an important effort to document and to interpret, spectral features of Solar System silicate crusts where glasses are present, but may be difficult to map. In previous work Carli et al. (2016) considered the composition of glassy igneous materials produced in Earth-like atmospheric conditions (i.e. oxidized conditions). Here, we expand on that effort by including glasses formed under more reducing condition. In this study, glasses were produced at -9.3 log fO2 and 1400 ˚ C for a duration of 4 h at the Department of Earth and Environmental Sciences at the University of Munich using a gas-mixing furnace. The major element composition, sample homogeneity, and the Fe3+/Fetot. ratio of run products were analytically determined. Moreover, Raman spectra of the same samples were also acquired. Afterwards, powders were produced with nine-grain size from 250-224 μm to 50-20 μm and measured in bidirectional reflectance at Spectroscopy LABoratory (IAPS-INAF, Rome). Reflectance spectra were acquired from 0.35 to 2.5 μm with a Field-Pro Spectrometer mounted on a goniometer. Spectra were obtained with incident and emission angles of 30˚ and 0˚ , respectively. Spectra showed both diagnostic bands, reflectance diminished with increasing iron abundance. The comparison with spectra collected from samples sythetized at "Earth-like" atmospheric conditions showed: 1) Relatively higher reflectance in the visible; 2) less red slope in the IR; 3) deeper 1.1 μm absorption band. Following Carli et al. (2016, Icarus), for all the spectra acquired at each grain size, we apply the radiative transfer model to estimate the optical constant as a wavelength's function. Finally, we will report the retrieved optical constants for our samples and we will compare them with those obtained from the same composition but at "Earth-like" atmospheric conditions. Reference: Carli et al. 2016, Icarus, doi:10.1016/j.icarus.2015.10.032.

  3. 21st Century Glass-Steagall Act of 2013

    THOMAS, 113th Congress

    Rep. Tierney, John F. [D-MA-6

    2013-12-11

    House - 01/27/2014 Referred to the Subcommittee on Regulatory Reform, Commercial And Antitrust Law. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  4. Selected Bibliography on Fiber-Reinforced Cement and Concrete.

    DTIC Science & Technology

    1976-08-01

    A listing of 660 references with author index is given for fiber reinforced cement and gypsum matrices, mortars, and concretes. Fiber types include steel, glass, plastic, asbestos, organic, carbon, and others. (Author)

  5. Semantics, Cross-Cultural Style

    ERIC Educational Resources Information Center

    Machery, Edouard; Mallon, Ron; Nichols, Shaun; Stich, Stephen P.

    2004-01-01

    Theories of reference have been central to analytic philosophy, and two views, "the descriptivist view of reference" and "the causal-historical view of reference," have dominated the field. In this research tradition, theories of reference are assessed by consulting one's intuitions about the reference of terms in hypothetical situations. However,…

  6. Equilibrium and nonequilibrium properties of Boolean decision problems on scale-free graphs with competing interactions with external biases

    NASA Astrophysics Data System (ADS)

    Zhu, Zheng; Andresen, Juan Carlos; Janzen, Katharina; Katzgraber, Helmut G.

    2013-03-01

    We study the equilibrium and nonequilibrium properties of Boolean decision problems with competing interactions on scale-free graphs in a magnetic field. Previous studies at zero field have shown a remarkable equilibrium stability of Boolean variables (Ising spins) with competing interactions (spin glasses) on scale-free networks. When the exponent that describes the power-law decay of the connectivity of the network is strictly larger than 3, the system undergoes a spin-glass transition. However, when the exponent is equal to or less than 3, the glass phase is stable for all temperatures. First we perform finite-temperature Monte Carlo simulations in a field to test the robustness of the spin-glass phase and show, in agreement with analytical calculations, that the system exhibits a de Almeida-Thouless line. Furthermore, we study avalanches in the system at zero temperature to see if the system displays self-organized criticality. This would suggest that damage (avalanches) can spread across the whole system with nonzero probability, i.e., that Boolean decision problems on scale-free networks with competing interactions are fragile when not in thermal equilibrium.

  7. Assessment of NPP VIIRS Albedo Over Heterogeneous Crop Land in Northern China

    NASA Astrophysics Data System (ADS)

    Wu, Xiaodan; Wen, Jianguang; Xiao, Qing; Yu, Yunyue; You, Dongqin; Hueni, Andreas

    2017-12-01

    In this paper, the accuracy of Suomi National Polar-orbiting Partnership Visible Infrared Imaging Radiometer Suite (VIIRS) land surface albedo, which is derived from the direct estimation algorithm, was assessed using ground-based albedo observations from a wireless sensor network over a heterogeneous cropland in the Huailai station, northern China. Data from six nodes spanning 2013-2014 over vegetation, bare soil, and mixed terrain surfaces were utilized to provide ground reference at VIIRS pixel scale. The performance of VIIRS albedo was also compared with Global LAnd Surface Satellite (GLASS) and Moderate Resolution Imaging Spectroradiometer (MODIS) albedos (Collection 5 and 6). The results indicate that the current granular VIIRS albedo has a high accuracy with a root-mean-square error of 0.02 for typical land covers. They are significantly correlated with ground references indicated by a correlation coefficient (R) of 0.73. The VIIRS albedo shows distinct advantages to GLASS and MODIS albedos over bare soil and mixed-cover surfaces, while it is inferior to the other two products over vegetated surfaces. Furthermore, its time continuity and the ability to capture the abrupt change of surface albedo are better than that of GLASS and MODIS albedo.

  8. The power of a musical instrument: Franklin, the Mozarts, Mesmer, and the glass armonica.

    PubMed

    Gallo, D A; Finger, S

    2000-11-01

    In 1761 Benjamin Franklin invented the armonica (often referred to as the glass harmonica), an instrument designed to simplify the playing of the musical glasses. The instrument immediately became popular and inspired compositions by Wolfgang Mozart, who had the opportunity to hear and play one at the house of Franz Anton Mesmer. Armonica music was used by Mesmer in his séances, because he felt it could promote healing by propagating a mystical fluid that he called animal magnetism through the body. After Mesmer's theories were debunked by a highly respected panel of scientists, the armonica fell out of vogue. Because Franklin was on the panel that examined the discredited mesmerism, he indirectly contributed to his own invention's demise.

  9. Evaluation of a High-Throughput Peptide Reactivity Format Assay for Assessment of the Skin Sensitization Potential of Chemicals

    PubMed Central

    Wong, Chin Lin; Lam, Ai-Leen; Smith, Maree T.; Ghassabian, Sussan

    2016-01-01

    The direct peptide reactivity assay (DPRA) is a validated method for in vitro assessment of the skin sensitization potential of chemicals. In the present work, we describe a peptide reactivity assay using 96-well plate format and systematically identified the optimal assay conditions for accurate and reproducible classification of chemicals with known sensitizing capacity. The aim of the research is to ensure that the analytical component of the peptide reactivity assay is robust, accurate, and reproducible in accordance with criteria that are used for the validation of bioanalytical methods. Analytical performance was evaluated using quality control samples (QCs; heptapeptides at low, medium, and high concentrations) and incubation of control chemicals (chemicals with known sensitization capacity, weak, moderate, strong, extreme, and non-sensitizers) with each of three synthetic heptapeptides, viz Cor1-C420 (Ac-NKKCDLF), cysteine- (Ac-RFAACAA), and lysine- (Ac-RFAAKAA) containing heptapeptides. The optimal incubation temperature for all three heptapeptides was 25°C. Apparent heptapeptide depletion was affected by vial material composition. Incubation of test chemicals with Cor1-C420, showed that peptide depletion was unchanged in polypropylene vials over 3-days storage in an autosampler but this was not the case for borosilicate glass vials. For cysteine-containing heptapeptide, the concentration was not stable by day 3 post-incubation in borosilicate glass vials. Although the lysine-containing heptapeptide concentration was unchanged in both polypropylene and borosilicate glass vials, the apparent extent of lysine-containing heptapeptide depletion by ethyl acrylate, differed between polypropylene (24.7%) and glass (47.3%) vials. Additionally, the peptide-chemical complexes for Cor1-C420-cinnamaldehyde and cysteine-containing heptapeptide-2, 4-dinitrochlorobenzene were partially reversible during 3-days of autosampler storage. These observations further highlight the difficulty in adapting in vitro methods to high-throughput format for screening the skin sensitization potential of large numbers of chemicals whilst ensuring that the data produced are both accurate and reproducible. PMID:27014067

  10. Irregular analytical errors in diagnostic testing - a novel concept.

    PubMed

    Vogeser, Michael; Seger, Christoph

    2018-02-23

    In laboratory medicine, routine periodic analyses for internal and external quality control measurements interpreted by statistical methods are mandatory for batch clearance. Data analysis of these process-oriented measurements allows for insight into random analytical variation and systematic calibration bias over time. However, in such a setting, any individual sample is not under individual quality control. The quality control measurements act only at the batch level. Quantitative or qualitative data derived for many effects and interferences associated with an individual diagnostic sample can compromise any analyte. It is obvious that a process for a quality-control-sample-based approach of quality assurance is not sensitive to such errors. To address the potential causes and nature of such analytical interference in individual samples more systematically, we suggest the introduction of a new term called the irregular (individual) analytical error. Practically, this term can be applied in any analytical assay that is traceable to a reference measurement system. For an individual sample an irregular analytical error is defined as an inaccuracy (which is the deviation from a reference measurement procedure result) of a test result that is so high it cannot be explained by measurement uncertainty of the utilized routine assay operating within the accepted limitations of the associated process quality control measurements. The deviation can be defined as the linear combination of the process measurement uncertainty and the method bias for the reference measurement system. Such errors should be coined irregular analytical errors of the individual sample. The measurement result is compromised either by an irregular effect associated with the individual composition (matrix) of the sample or an individual single sample associated processing error in the analytical process. Currently, the availability of reference measurement procedures is still highly limited, but LC-isotope-dilution mass spectrometry methods are increasingly used for pre-market validation of routine diagnostic assays (these tests also involve substantial sets of clinical validation samples). Based on this definition/terminology, we list recognized causes of irregular analytical error as a risk catalog for clinical chemistry in this article. These issues include reproducible individual analytical errors (e.g. caused by anti-reagent antibodies) and non-reproducible, sporadic errors (e.g. errors due to incorrect pipetting volume due to air bubbles in a sample), which can both lead to inaccurate results and risks for patients.

  11. Intercomparison and validation of MODIS and GLASS leaf area index (LAI) products over mountain areas: A case study in southwestern China

    NASA Astrophysics Data System (ADS)

    Jin, Huaan; Li, Ainong; Bian, Jinhu; Nan, Xi; Zhao, Wei; Zhang, Zhengjian; Yin, Gaofei

    2017-03-01

    The validation study of leaf area index (LAI) products over rugged surfaces not only gives additional insights into data quality of LAI products, but deepens understanding of uncertainties regarding land surface process models depended on LAI data over complex terrain. This study evaluated the performance of MODIS and GLASS LAI products using the intercomparison and direct validation methods over southwestern China. The spatio-temporal consistencies, such as the spatial distributions of LAI products and their statistical relationship as a function of topographic indices, time, and vegetation types, respectively, were investigated through intercomparison between MODIS and GLASS products during the period 2011-2013. The accuracies and change ranges of these two products were evaluated against available LAI reference maps over 10 sampling regions which standed for typical vegetation types and topographic gradients in southwestern China. The results show that GLASS LAI exhibits higher percentage of good quality data (i.e. successful retrievals) and smoother temporal profiles than MODIS LAI. The percentage of successful retrievals for MODIS and GLASS is vulnerable to topographic indices, especially to relief amplitude. Besides, the two products do not capture seasonal dynamics of crop, especially in spring over heterogeneously hilly regions. The yearly mean LAI differences between MODIS and GLASS are within ±0.5 for 64.70% of the total retrieval pixels over southwestern China. The spatial distribution of mean differences and temporal profiles of these two products are inclined to be dominated by vegetation types other than topographic indices. The spatial and temporal consistency of these two products is good over most area of grasses/cereal crops; however, it is poor for evergreen broadleaf forest. MODIS presents more reliable change range of LAI than GLASS through comparison with fine resolution reference maps over most of sampling regions. The accuracies of direct validation are obtained for GLASS LAI (r = 0.35, RMSE = 1.72, mean bias = -0.71) and MODIS LAI (r = 0.49, RMSE = 1.75, mean bias = -0.67). GLASS performs similarly to MODIS, but may be marginally inferior to MODIS based on our direct validation results. The validation experience demonstrates the necessity and importance of topographic consideration for LAI estimation over mountain areas. Considerable attention will be paid to the improvements of surface reflectance, retrieval algorithm and land cover types so as to enhance the quality of LAI products in topographically complex terrain.

  12. Standard Reference Materials (SRMs) for the Calibration and Validation of Analytical Methods for PCBs (as Aroclor Mixtures)

    PubMed Central

    Poster, Dianne L.; Schantz, Michele M.; Leigh, Stefan D.; Wise, Stephen A.

    2004-01-01

    Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually) in methanol and transformer oil, mixed, and transferred to amber glass ampoules in approximately 1.2 mL aliquots. Gas chromatography with electron capture detection (GC-ECD) has been used to verify the gravimetric data for each solution and transformer oil SRM. Liquid chromatography was used for the isolation of the Aroclors from the transformer oil SRMs prior to GC-ECD analysis. Separate calibration solutions and oils were prepared with Aroclor levels similar to those in each methanol solution and transformer oil SRM and were processed alongside the samples. The GC-ECD response of each Aroclor was monitored relative to internal standards that were added to the complex mixtures for quantification. The gravimetric concentrations of Aroclors 1242 and 1254 in methanol were also examined by the same method of analysis (GC-ECD) using several different sources of Aroclors and two different capillary GC columns: a 5 % phenyl methylpolysiloxane phase and a relatively non-polar phase. The preparation of the materials, the gas chromatographic results, and the certified concentration values for each Aroclor SRM are described in this paper. PMID:27366608

  13. Orbiter/carrier separation for the ALT free flight no. 1 reference trajectories. Mission planning, mission analysis and software formulation

    NASA Technical Reports Server (NTRS)

    Glenn, G. M.

    1976-01-01

    Details of the generation of the separation trajectories are discussed. The analysis culminated in definition of separation trajectories between physical separation and orbiter/carrier vortex clearance. Specifications, assumptions and analytical approach used to generate the separation trajectories are presented. Results of the analytical approach are evaluated. Conclusions and recommendations are summarized. Supporting references are listed.

  14. The meaning of the "universal" WLF parameters of glass-forming polymer liquids

    NASA Astrophysics Data System (ADS)

    Dudowicz, Jacek; Douglas, Jack F.; Freed, Karl F.

    2015-01-01

    Although the Williams-Landell-Ferry (WLF) equation for the segmental relaxation time τ(T) of glass-forming materials is one of the most commonly encountered relations in polymer physics, its molecular basis is not well understood. The WLF equation is often claimed to be equivalent to the Vogel-Fulcher-Tammann (VFT) equation, even though the WLF expression for τ(T) contains no explicit dependence on the fragility parameter D of the VFT equation, while the VFT equation lacks any explicit reference to the glass transition temperature Tg, the traditionally chosen reference temperature in the WLF equation. The observed approximate universality of the WLF parameters C1 ( g ) and C2 ( g ) implies that τ(T) depends only on T-Tg, a conclusion that seems difficult to reconcile with the VFT equation where the fragility parameter D largely governs the magnitude of τ(T). The current paper addresses these apparent inconsistencies by first evaluating the macroscopic WLF parameters C1 ( g ) and C2 ( g ) from the generalized entropy theory of glass-formation and then by determining the dependence of C1 ( g ) and C2 ( g ) on the microscopic molecular parameters (including the strength of the cohesive molecular interactions and the degree of chain stiffness) and on the molar mass of the polymer. Attention in these calculations is restricted to the temperature range (Tg < T < Tg + 100 K), where both the WLF and VFT equations apply.

  15. Analytical solution for haze values of aluminium-induced texture (AIT) glass superstrates for a-Si:H solar cells.

    PubMed

    Sahraei, Nasim; Forberich, Karen; Venkataraj, Selvaraj; Aberle, Armin G; Peters, Marius

    2014-01-13

    Light scattering at randomly textured interfaces is essential to improve the absorption of thin-film silicon solar cells. Aluminium-induced texture (AIT) glass provides suitable scattering for amorphous silicon (a-Si:H) solar cells. The scattering properties of textured surfaces are usually characterised by two properties: the angularly resolved intensity distribution and the haze. However, we find that the commonly used haze equations cannot accurately describe the experimentally observed spectral dependence of the haze of AIT glass. This is particularly the case for surface morphologies with a large rms roughness and small lateral feature sizes. In this paper we present an improved method for haze calculation, based on the power spectral density (PSD) function of the randomly textured surface. To better reproduce the measured haze characteristics, we suggest two improvements: i) inclusion of the average lateral feature size of the textured surface into the haze calculation, and ii) considering the opening angle of the haze measurement. We show that with these two improvements an accurate prediction of the haze of AIT glass is possible. Furthermore, we use the new equation to define optimum morphology parameters for AIT glass to be used for a-Si:H solar cell applications. The autocorrelation length is identified as the critical parameter. For the investigated a-Si:H solar cells, the optimum autocorrelation length is shown to be 320 nm.

  16. User`s and reference guide to the INEL RML/analytical radiochemistry sample tracking database version 1.00

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Femec, D.A.

    This report discusses the sample tracking database in use at the Idaho National Engineering Laboratory (INEL) by the Radiation Measurements Laboratory (RML) and Analytical Radiochemistry. The database was designed in-house to meet the specific needs of the RML and Analytical Radiochemistry. The report consists of two parts, a user`s guide and a reference guide. The user`s guide presents some of the fundamentals needed by anyone who will be using the database via its user interface. The reference guide describes the design of both the database and the user interface. Briefly mentioned in the reference guide are the code-generating tools, CREATE-SCHEMAmore » and BUILD-SCREEN, written to automatically generate code for the database and its user interface. The appendices contain the input files used by the these tools to create code for the sample tracking database. The output files generated by these tools are also included in the appendices.« less

  17. Food adulteration analysis without laboratory prepared or determined reference food adulterant values.

    PubMed

    Kalivas, John H; Georgiou, Constantinos A; Moira, Marianna; Tsafaras, Ilias; Petrakis, Eleftherios A; Mousdis, George A

    2014-04-01

    Quantitative analysis of food adulterants is an important health and economic issue that needs to be fast and simple. Spectroscopy has significantly reduced analysis time. However, still needed are preparations of analyte calibration samples matrix matched to prediction samples which can be laborious and costly. Reported in this paper is the application of a newly developed pure component Tikhonov regularization (PCTR) process that does not require laboratory prepared or reference analysis methods, and hence, is a greener calibration method. The PCTR method requires an analyte pure component spectrum and non-analyte spectra. As a food analysis example, synchronous fluorescence spectra of extra virgin olive oil samples adulterated with sunflower oil is used. Results are shown to be better than those obtained using ridge regression with reference calibration samples. The flexibility of PCTR allows including reference samples and is generic for use with other instrumental methods and food products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Structural investigation of Zn doped sodium bismuth borate glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhatia, V., E-mail: vijetabhatia0712@gmail.com; Kumar, D.; Singh, D.

    2016-05-06

    A series of Bismuth Borate Oxide Glass samples with composition x(ZnO):(15-x)Na{sub 2}O:15Bi{sub 2}O{sub 3}:70B{sub 2}O{sub 3} (variation in x is from 6 to 12 mole %) have been prepared by conventional melt quenching technique. All the chemicals used were of Analytical Grade. In order to verify the amorphous nature of the prepared samples the X-Ray Diffraction (XRD) was done. The physical and structural properties have been explored by using the techniques such as density, molar volume and FTIR in order to understand the effect of alkali and transition metal ions on the structure of these glasses. The results obtained bymore » these techniques are in good agreement to one another and with literature as well. With the increase in the content of ZnO, the increase in density and some variations in structural coordination (ratio of BO{sub 3} & BO{sub 4} structural units) have been observed.« less

  19. Characterization of Deposits on Glass Substrate as a Tool in Failure Analysis: The Orbiter Vehicle Columbia Case Study

    NASA Technical Reports Server (NTRS)

    Olivas, J. D.; Melroy, P.; McDanels, S.; Wallace, T.; Zapata, M. C.

    2006-01-01

    In connection with the accident investigation of the space shuttle Columbia, an analysis methodology utilizing well established microscopic and spectroscopic techniques was implemented for evaluating the environment to which the exterior fused silica glass was exposed. Through the implementation of optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, transmission electron microscopy, and electron diffraction, details emerged regarding the manner in which a charred metallic deposited layer formed on top of the exposed glass. Due to nature of the substrate and the materials deposited, the methodology proved to allow for a more detailed analysis of the vehicle breakup. By contrast, similar analytical methodologies on metallic substrates have proven to be challenging due to strong potential for error resulting from substrate contamination. This information proved to be valuable to not only those involved in investigating the break up of Columbia, but also provides a potential guide for investigating future high altitude and high energy accidents.

  20. Analytical analysis of solar thermal collector with glass and Fresnel lens glazing

    NASA Astrophysics Data System (ADS)

    Zulkifle, Idris; Ruslan, Mohd Hafidz Hj; Othman, Mohd Yusof Hj; Ibarahim, Zahari

    2018-04-01

    Solar thermal collector is a system that converts solar radiation to heat. The heat will raise the temperature higher than the ambient temperature. Absorber and glazing are two important components in order to increase the temperature of the collector. The thermal absorber will release heat by convection and as radiation to the surrounding. These losses will be reduced by glazing. Other than that, glazing is beneficial for protecting the collector from dust and water. This study discusses about modelling of solar thermal collector effects of different mass flow rates with different glazing for V-groove flat plate solar collectors. The glazing used was the glass and linear Fresnel lens. Concentration ratio in this modelling was 1.3 for 0.1m solar collector thickness. Results show that solar collectors with linear Fresnel lens has the highest efficiency value of 71.18% compared to solar collectors with glass which has efficiency 54.10% with same operation conditions.

  1. Theoretical analysis of optical poling and frequency doubling effect based on classical model

    NASA Astrophysics Data System (ADS)

    Feng, Xi; Li, Fuquan; Lin, Aoxiang; Wang, Fang; Chai, Xiangxu; Wang, Zhengping; Zhu, Qihua; Sun, Xun; Zhang, Sen; Sun, Xibo

    2018-03-01

    Optical poling and frequency doubling effect is one of the effective manners to induce second order nonlinearity and realize frequency doubling in glass materials. The classical model believes that an internal electric field is built in glass when it's exposed by fundamental and frequency-doubled light at the same time, and second order nonlinearity appears as a result of the electric field and the orientation of poles. The process of frequency doubling in glass is quasi phase matched. In this letter, the physical process of poling and doubling process in optical poling and frequency doubling effect is deeply discussed in detail. The magnitude and direction of internal electric field, second order nonlinear coefficient and its components, strength and direction of frequency doubled output signal, quasi phase matched coupled wave equations are given in analytic expression. Model of optical poling and frequency doubling effect which can be quantitatively analyzed are constructed in theory, which set a foundation for intensive study of optical poling and frequency doubling effect.

  2. Adsorption of Cationic Peptides to Solid Surfaces of Glass and Plastic

    PubMed Central

    Kristensen, Kasper; Henriksen, Jonas R.; Andresen, Thomas L.

    2015-01-01

    Cationic membrane-active peptides have been studied for years in the hope of developing them into novel types of therapeutics. In this article, we investigate an effect that might have significant experimental implications for investigators who wish to study these peptides, namely, that the peptides adsorb to solid surfaces of glass and plastic. Specifically, we use analytical HPLC to systematically quantify the adsorption of the three cationic membrane-active peptides mastoparan X, melittin, and magainin 2 to the walls of commonly used glass and plastic sample containers. Our results show that, at typical experimental peptide concentrations, 90% or more of the peptides might be lost from solution due to rapid adsorption to the walls of the sample containers. Thus, our results emphasize that investigators should always keep these adsorption effects in mind when designing and interpreting experiments on cationic membrane-active peptides. We conclude the article by discussing different strategies for reducing the experimental impact of these adsorption effects. PMID:25932639

  3. In vitro fluoride release from a different kind of conventional and resin modified glass-ionomer cements.

    PubMed

    Selimović-Dragaš, Mediha; Hasić-Branković, Lajla; Korać, Fehim; Đapo, Nermin; Huseinbegović, Amina; Kobašlija, Sedin; Lekić, Meliha; Hatibović-Kofman, Šahza

    2013-08-01

    Fluoride release is important characteristic of glass-ionomer cements. Quantity of fluoride ions released from the glass-ionomer cements has major importance in definition of their biological activity. The objectives of this study were to define the quantity of fluoride ions released from the experimental glass-ionomer cements and to define the effect of fluoride ions released from the experimental glass-ionomer cements on their cytotoxicity. Concentrations of the fluoride ions released in the evaluated glass-ionomer cements were measured indirectly, by the fluoride-selective WTW, F500 electrode potential, combined with reference R503/D electrode. Statistical analyses of F-ion concentrations released by all glass-ionomers evaluated at two time points, after 8 and after 24 hours, show statistically higher fluoride releases from RMGICs: Vitrebond, Fuji II LC and Fuji Plus, when compared to conventional glass-ionomer cements: Fuji Triage, Fuji IX GP Fast and Ketac Silver, both after 8 and after 24 hours. Correlation coefficient between concentrations of fluoride ion released by evaluated glass-ionomer cements and cytotoxic response of UMR-106 osteoblast cell-line are relatively high, but do not reach levels of biological significance. Correlation between concentrations of fluoride ion released and cytotoxic response of NIH3T3 mouse fibroblast cell line after 8 hours is high, positive and statistically significant for conventional GICs, Fuji Triage and Fuji IX GP Fast, and RMGIC, Fuji II LC. Statistically significant Correlation coefficient between concentrations of fluoride ion released and cytotoxic response of NIH3T3 cell line after 24 hours is defined for RMGIC Fuji II LC only.

  4. A method of mounting multiple otoliths for beam-based microchemical analyses

    USGS Publications Warehouse

    Donohoe, C.J.; Zimmerman, C.E.

    2010-01-01

    Beam-based analytical methods are widely used to measure the concentrations of elements and isotopes in otoliths. These methods usually require that otoliths be individually mounted and prepared to properly expose the desired growth region to the analytical beam. Most analytical instruments, such as LA-ICPMS and ion and electron microprobes, have sample holders that will accept only one to six slides or mounts at a time. We describe a method of mounting otoliths that allows for easy transfer of many otoliths to a single mount after they have been prepared. Such an approach increases the number of otoliths that can be analyzed in a single session by reducing the need open the sample chamber to exchange slides-a particularly time consuming step on instruments that operate under vacuum. For ion and electron microprobes, the method also greatly reduces the number of slides that must be coated with an electrical conductor prior to analysis. In this method, a narrow strip of cover glass is first glued at one end to a standard microscope slide. The otolith is then mounted in thermoplastic resin on the opposite, free end of the strip. The otolith can then be ground and flipped, if needed, by reheating the mounting medium. After otolith preparation is complete, the cover glass is cut with a scribe to free the otolith and up to 20 small otoliths can be arranged on a single petrographic slide. ?? 2010 The Author(s).

  5. GLASS: The Grism Lens-Amplified Survey From Space. HST Grism Spectroscopy of the Frontier Fields

    NASA Astrophysics Data System (ADS)

    Schmidt, Kasper B.; Schmidt

    The Grism Lens-Amplified Survey From Space (GLASS) is a 140 orbit spectroscopic survey of 10 massive galaxy clusters, including the six Hubble Frontier Fields. GLASS has observed the cluster cores with the HST-WFC3 G102 and G141 grisms providing a wide wavelength coverage in the near-infrared from roughly 0.8-1.7μm. The parallel fields were observed through the optical ACS G800L grism. Taking advantage of the lensing magnification of the clusters, GLASS reaches intrinsic spectroscopic 1σ flux limits of roughly 10-18erg/s/cm2 and improved spatial resolution for lensed sources behind the clusters. These features are particularly useful for the three main science drivers of GLASS which are, I) exploring the universe at the epoch of reionization, II) describe how metals cycle in and out of galaxies, and III) asses the environmental dependence of galaxy evolution. The former two benefit highly from the improved depth and increased resolution provided by the cluster lensing. Apart from the main science drivers, a slew of ancillary science has been enabled by the survey, including improving cluster lens modeling and searches for supernovae. Here we present the survey and the GLASS data releases, which are continuously being made available to the community through https://archive.stsci.edu/prepds/glass/. For further information we refer to Schmidt et al. (2014), Treu et al. (2015), and http://glass.physics.ucsb.edu.

  6. Catalog of Mount St. Helens 2004 - 2005 Tephra Samples with Major- and Trace-Element Geochemistry

    USGS Publications Warehouse

    Rowe, Michael C.; Thornber, Carl R.; Gooding, Daniel J.; Pallister, John S.

    2008-01-01

    This open-file report presents a catalog of information about 135 ash samples along with geochemical analyses of bulk ash, glass and individual mineral grains from tephra deposited as a result of volcanic activity at Mount St. Helens, Washington, from October 1, 2004 until August 15, 2005. This data, in conjunction with that in a companion report on 2004?2007 Mount St. Helens dome samples by Thornber and others (2008a) are presented in support of the contents of the U.S. Geological Survey Professional Paper 1750 (Sherrod and others, ed., 2008). Readers are referred to appropriate chapters in USGS Professional Paper 1750 for detailed narratives of eruptive activity during this time period and for interpretations of sample characteristics and geochemical data presented here. All ash samples reported herein are currently archived at the David A. Johnston Cascades Volcano Observatory in Vancouver, Washington. The Mount St. Helens 2004?2005 Tephra Sample Catalogue along with bulk, glass and mineral geochemistry are tabulated in 6 worksheets of the accompanying Microsoft Excel file, of2008-1131.xls. Samples in all tables are organized by collection date. Table 1 is a detailed catalog of sample information for tephra deposited downwind of Mount St. Helens between October 1, 2004 and August 18, 2005. Table 2 provides major- and trace-element analyses of 8 bulk tephra samples collected throughout that interval. Major-element compositions of 82 groundmass glass fragments, 420 feldspar grains, and 213 mafic (clinopyroxene, amphibole, hypersthene, and olivine) mineral grains from 12 ash samples collected between October 1, 2004 and March 8, 2005 are presented in tables 3 through 5. In addition, trace-element abundances of 198 feldspars from 11 ash samples (same samples as major-element analyses) are provided in table 6. Additional mineral and bulk ash analyses from 2004 and 2005 ash samples are published in chapters 30 (oxide thermometry; Pallister and others, 2008), 32 (amphibole major elements; Thornber and others, 2008b) and 37 (210Pb; 210Pb/226Pa; Reagan and others, 2008) of U.S. Geological Survey Professional Paper 1750 (Sherrod and others, 2008). A brief overview of sample collection methods is given below as an aid to deciphering the tephra sample catalog. This is followed by an explanation of the categories of sample information (column headers) in table 1. A summary of the analytical methods used to obtain the geochemical data in this report introduces the presentation of major- and trace-element geochemistry of Mount St. Helens 2004?2005 tephra samples in tables 2?6. Rhyolite glass standard analyses are reported (Appendix 1) to demonstrate the accuracy and precision of similar glass analyses presented herein.

  7. Sinking bubbles in stout beers

    NASA Astrophysics Data System (ADS)

    Lee, W. T.; Kaar, S.; O'Brien, S. B. G.

    2018-04-01

    A surprising phenomenon witnessed by many is the sinking bubbles seen in a settling pint of stout beer. Bubbles are less dense than the surrounding fluid so how does this happen? Previous work has shown that the explanation lies in a circulation of fluid promoted by the tilted sides of the glass. However, this work has relied heavily on computational fluid dynamics (CFD) simulations. Here, we show that the phenomenon of sinking bubbles can be predicted using a simple analytic model. To make the model analytically tractable, we work in the limit of small bubbles and consider a simplified geometry. The model confirms both the existence of sinking bubbles and the previously proposed mechanism.

  8. Analysis of Tile-Reinforced Composite Armor. Part 1; Advanced Modeling and Strength Analyses

    NASA Technical Reports Server (NTRS)

    Davila, C. G.; Chen, Tzi-Kang; Baker, D. J.

    1998-01-01

    The results of an analytical and experimental study of the structural response and strength of tile-reinforced components of the Composite Armored Vehicle are presented. The analyses are based on specialized finite element techniques that properly account for the effects of the interaction between the armor tiles, the surrounding elastomers, and the glass-epoxy sublaminates. To validate the analytical predictions, tests were conducted with panels subjected to three-point bending loads. The sequence of progressive failure events for the laminates is described. This paper describes the results of Part 1 of a study of the response and strength of tile-reinforced composite armor.

  9. 21st Century Glass-Steagall Act of 2013

    THOMAS, 113th Congress

    Sen. Warren, Elizabeth [D-MA

    2013-07-11

    Senate - 07/11/2013 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  10. Analytical study into El Greco's baptism of Christ: clues to the genius of his palette

    NASA Astrophysics Data System (ADS)

    Daniilia, S.; Andrikopoulos, K. S.; Sotiropoulou, S.; Karapanagiotis, I.

    2008-03-01

    What the discerning gaze of the art historian has deduced from comparisons in style namely, that the unsigned Baptism of Christ (dated 1567) comes from the hand of the master Cretan painter, El Greco is now investigated by the dispassionate eye of technology. The examination by means of analytical methods of diagnosis aimed at making an in-depth investigation into the hitherto unknown personal traits of the artist’s painting technique. By observing the cross-sections under the optical microscope and analyzing the materials through the application of μRaman and μFTIR spectroscopies and of high performance liquid chromatography (HPCL/DAD), it was possible to reveal the “fingerprints” of the artist’s brushwork. In his masterfully executed Baptism, El Greco has succeeded through his perspicacity and ingenuity, to combine traditional techniques of Byzantine icon-painting with the innovative practices of Venetian Renaissance art. The artist’s palette contains mineral, earth and natural organic pigments, as well as some synthetic ones of glass or resin base: lapis lazuli, indigo, lead-tin yellow, orpiment, yellow ochre, cochineal lake, copper resinate, burnt umber, lead white and carbon black. Furthermore, he introduces a layer of white imprimatura containing varied combinations of powdered glass and lead white. The detection of substantial similarities between the glass varieties used in the Baptism and those found in works by Venetian painters contemporary with El Greco (such as Tintoretto) further attests ascription of the Baptism to the period of the artist’s brief sojourn in Venice.

  11. A thermal biosensor based on enzyme reaction.

    PubMed

    Zheng, Yi-Hua; Hua, Tse-Chao; Xu, Fei

    2005-01-01

    Application of the thermal biosensor as analytical tool is promising due to advantages as universal, simplicity and quick response. A novel thermal biosensor based on enzyme reaction has been developed. This biosensor is a flow injection analysis system and consists of two channels with enzyme reaction column and reference column. The reference column, which is set for eliminating the unspecific heat, is inactived on special enzyme reaction of the ingredient to be detected. The special enzyme reaction takes places in the enzyme reaction column at a constant temperature realizing by a thermoelectric thermostat. Thermal sensor based on the thermoelectric module containing 127 serial BiTe-thermocouples is used to monitor the temperature difference between two streams from the enzyme reaction column and the reference column. The analytical example for dichlorvos shows that this biosensor can be used as analytical tool in medicine and biology.

  12. Do Workers Who Experience Conflict between the Work and Family Domains Hit a "Glass Ceiling?": A Meta-Analytic Examination

    ERIC Educational Resources Information Center

    Hoobler, Jenny M.; Hu, Jia; Wilson, Morgan

    2010-01-01

    Based in Conservation of Resources (COR; Hobfoll, 1989) and self-verification (Swann, 1987) theories, we argue that when workers experience conflict between the work and family domains, this should have implications for evaluations of their work performance and ultimately affect more "objective" career outcomes such as salary and hierarchical…

  13. Clinical chemistry reference values for 75-year-old apparently healthy persons.

    PubMed

    Huber, Klaus Roland; Mostafaie, Nazanin; Stangl, Gerhard; Worofka, Brigitte; Kittl, Eva; Hofmann, Jörg; Hejtman, Milos; Michael, Rainer; Weissgram, Silvia; Leitha, Thomas; Jungwirth, Susanne; Fischer, Peter; Tragl, Karl-Heinz; Bauer, Kurt

    2006-01-01

    Clinical chemistry reference values for elderly persons are sparse and mostly intermixed with those for younger subjects. To understand the links between metabolism and aging, it is paramount to differentiate between "normal" physiological processes in apparently healthy elderly subjects and metabolic changes due to long-lasting diseases. The Vienna Transdanube Aging (VITA) study, which began in 2000 and is continuing, will allow us to do just that, because more than 600 male and female volunteers aged exactly 75 years (to exclude any influence of the "aging" factor in this cohort) are participating in this study. Extensive clinical, neurological, biochemical, psychological, genetic, and radiological analyses, with a special emphasis on consumption of medication and abuse of drugs, were performed on each of the probands. The multitude of data and questionnaires obtained made possible an a posteriori approach to select individuals fulfilling criteria for a reference sample group of apparently healthy 75-year-old subjects for our study. Specific analytes were quantified on automated clinical analyzers, while manual methods were used for hormonal analytes. All clinical chemistry analytes were evaluated using in-depth statistical analyses with SPSS for Windows. In all, reference intervals for 45 analytes could be established. These include routine parameters for the assessment of organ functions, as well as hormone concentrations and hematological appraisals. Because all patients were reevaluated after exactly 30 months in the course of this study, we had the opportunity to reassess their health status at the age of 77.5 years. This was very useful for validation of the first round data set. Data of the second round evaluation corroborate the reference limits of the baseline analysis and further confirm our inclusion and exclusion criteria. In summary, we have established a reliable set of reference data for hormonal, hematological, and clinical chemistry analytes for elderly subjects. These values will be very useful for our future attempts to correlate disease states and aging processes with metabolic factors.

  14. Metal-Organic Framework Modified Glass Substrate for Analysis of Highly Volatile Chemical Warfare Agents by Paper Spray Mass Spectrometry.

    PubMed

    Dhummakupt, Elizabeth S; Carmany, Daniel O; Mach, Phillip M; Tovar, Trenton M; Ploskonka, Ann M; Demond, Paul S; DeCoste, Jared B; Glaros, Trevor

    2018-03-07

    Paper spray mass spectrometry has been shown to successfully analyze chemical warfare agent (CWA) simulants. However, due to the volatility differences between the simulants and real G-series (i.e., sarin, soman) CWAs, analysis from an untreated paper substrate proved difficult. To extend the analytical lifetime of these G-agents, metal-organic frameworks (MOFs) were successfully integrated onto the paper spray substrates to increase adsorption and desorption. In this study, several MOFs and nanoparticles were tested to extend the analytical lifetimes of sarin, soman, and cyclosarin on paper spray substrates. It was found that the addition of either UiO-66 or HKUST-1 to the paper substrate increased the analytical lifetime of the G-agents from less than 5 min detectability to at least 50 min.

  15. Fourier Transform Infrared Absorption Spectroscopy for Quantitative Analysis of Gas Mixtures at Low Temperatures for Homeland Security Applications.

    PubMed

    Meier, D C; Benkstein, K D; Hurst, W S; Chu, P M

    2017-05-01

    Performance standard specifications for point chemical vapor detectors are established in ASTM E 2885-13 and ASTM E 2933-13. The performance evaluation of the detectors requires the accurate delivery of known concentrations of the chemical target to the system under test. Referee methods enable the analyte test concentration and associated uncertainties in the analyte test concentration to be validated by independent analysis, which is especially important for reactive analytes. This work extends the capability of a previously demonstrated method for using Fourier transform infrared (FT-IR) absorption spectroscopy for quantitatively evaluating the composition of vapor streams containing hazardous materials at Acute Exposure Guideline Levels (AEGL) to include test conditions colder than laboratory ambient temperatures. The described method covers the use of primary reference spectra to establish analyte concentrations, the generation of secondary reference spectra suitable for measuring analyte concentrations under specified testing environments, and the use of additional reference spectra and spectral profile strategies to mitigate the uncertainties due to impurities and water condensation within the low-temperature (7 °C, -5 °C) test cell. Important benefits of this approach include verification of the test analyte concentration with characterized uncertainties by in situ measurements co-located with the detector under test, near-real-time feedback, and broad applicability to toxic industrial chemicals.

  16. Fourier Transform Infrared Absorption Spectroscopy for Quantitative Analysis of Gas Mixtures at Low Temperatures for Homeland Security Applications

    PubMed Central

    Meier, D.C.; Benkstein, K.D.; Hurst, W.S.; Chu, P.M.

    2016-01-01

    Performance standard specifications for point chemical vapor detectors are established in ASTM E 2885-13 and ASTM E 2933-13. The performance evaluation of the detectors requires the accurate delivery of known concentrations of the chemical target to the system under test. Referee methods enable the analyte test concentration and associated uncertainties in the analyte test concentration to be validated by independent analysis, which is especially important for reactive analytes. This work extends the capability of a previously demonstrated method for using Fourier transform infrared (FT-IR) absorption spectroscopy for quantitatively evaluating the composition of vapor streams containing hazardous materials at Acute Exposure Guideline Levels (AEGL) to include test conditions colder than laboratory ambient temperatures. The described method covers the use of primary reference spectra to establish analyte concentrations, the generation of secondary reference spectra suitable for measuring analyte concentrations under specified testing environments, and the use of additional reference spectra and spectral profile strategies to mitigate the uncertainties due to impurities and water condensation within the low-temperature (7 °C, −5 °C) test cell. Important benefits of this approach include verification of the test analyte concentration with characterized uncertainties by in situ measurements co-located with the detector under test, near-real-time feedback, and broad applicability to toxic industrial chemicals. PMID:28090126

  17. Liquid-liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel.

    PubMed

    Pereira, Andréia C; Rocha, Fábio R P

    2014-06-04

    A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I3(-) reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I2/100 g with a detection limit of 5 g I2/100 g. A coefficient of variation of 1.7% (n=10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel. Copyright © 2014. Published by Elsevier B.V.

  18. Recent progress in preparation and application of microfluidic chip electrophoresis

    NASA Astrophysics Data System (ADS)

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao

    2015-05-01

    Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast.

  19. Determination of work of adhesion of gelatin hydrogels on a glass substrate

    NASA Astrophysics Data System (ADS)

    Thakre, Avinash A.; Singh, Arun K.

    2018-04-01

    In this article, work of adhesion (w adh ) of soft gelatin hydrogels on a smooth glass substrate is determined experimentally using the wedge adhesion test. The results showed that w adh decreases with the increase in gelatin concentration in the hydrogels but the same is found to be independent of thickness of hydrogel specimen. These results are used further for establishing a scaling law between w adh and mesh size (ξ) of the three dimensional structure present in the hydrogel as w adh ∼ ξ 8.6. Finite element analysis is also carried out for validating the fracture stability of wedge test in view of analytical prediction. At the end, practical significance of the present study is also discussed.

  20. Layer-by-layer polyelectrolyte coating for surface-enhanced Raman scattering on gold nanostars inside hollow core photonic crystal fibers

    NASA Astrophysics Data System (ADS)

    Burmistrova, Natalia A.; Bondarenko, Sergei D.; Bratashov, Daniil N.; Shuvalov, Andrei A.; Chibrova, Anastasiya A.; Khlebtsov, Boris N.; Skibina, Julia S.; Goryacheva, Irina Y.

    2018-04-01

    Photonic crystal fibers with hollow core (HC PCFs) are a specific class of optical fibers characterized by microstructure with periodic holes oriented along fiber. The combination of HC PCF with Raman spectroscopy for biosensors creation is attractive in the terms of the low sample volume, the possibility to increase the integration time without sample degradation and maintaining constant focus during experiments. Here we propose layer-by-layer polyelectrolyte coating of HC PCF inner surface in order to obtain charge-selective absorption of analyte, stabilization of Surface-Enhanced Raman scattering (SERS)-active gold nanoparticles. Distance between SERS hotspots and glass reduces nonlinear signals from glass, and increases signal-to-noise ratio of SERS spectra.

  1. Opportunities for bead-based multiplex assays in veterinary diagnostic laboratories

    USDA-ARS?s Scientific Manuscript database

    Bead based multiplex assays (BBMA) also referred to as Luminex, MultiAnalyte Profiling or cytometric bead array (CBA) assays, are applicable for high throughput, simultaneous detection of multiple analytes in solution (from several, up to 50-500 analytes within a single, small sample volume). Curren...

  2. [Studies on the identification of psychotropic substances. VIII. Preparation and various analytical data of reference standard of some stimulants, amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex].

    PubMed

    Shimamine, M; Takahashi, K; Nakahara, Y

    1992-01-01

    The Reference Standards for amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex were prepared. Their purities determined by HPLC were more than 99.5%. For the identification and determination of these six drugs, their analytical data were measured and discussed by TLC, UV, IR, HPLC, GC/MS and NMR.

  3. Active matrix-based collection of airborne analytes: an analyte recording chip providing exposure history and finger print.

    PubMed

    Fang, Jun; Park, Se-Chul; Schlag, Leslie; Stauden, Thomas; Pezoldt, Jörg; Jacobs, Heiko O

    2014-12-03

    In the field of sensors that target the detection of airborne analytes, Corona/lens-based-collection provides a new path to achieve a high sensitivity. An active-matrix-based analyte collection approach referred to as "airborne analyte memory chip/recorder" is demonstrated, which takes and stores airborne analytes in a matrix to provide an exposure history for off-site analysis. © 2014 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Inkjet-printed point-of-care immunoassay on a nanoscale polymer brush enables subpicomolar detection of analytes in blood

    NASA Astrophysics Data System (ADS)

    Joh, Daniel Y.; Hucknall, Angus M.; Wei, Qingshan; Mason, Kelly A.; Lund, Margaret L.; Fontes, Cassio M.; Hill, Ryan T.; Blair, Rebecca; Zimmers, Zackary; Achar, Rohan K.; Tseng, Derek; Gordan, Raluca; Freemark, Michael; Ozcan, Aydogan; Chilkoti, Ashutosh

    2017-08-01

    The ELISA is the mainstay for sensitive and quantitative detection of protein analytes. Despite its utility, ELISA is time-consuming, resource-intensive, and infrastructure-dependent, limiting its availability in resource-limited regions. Here, we describe a self-contained immunoassay platform (the “D4 assay”) that converts the sandwich immunoassay into a point-of-care test (POCT). The D4 assay is fabricated by inkjet printing assay reagents as microarrays on nanoscale polymer brushes on glass chips, so that all reagents are “on-chip,” and these chips show durable storage stability without cold storage. The D4 assay can interrogate multiple analytes from a drop of blood, is compatible with a smartphone detector, and displays analytical figures of merit that are comparable to standard laboratory-based ELISA in whole blood. These attributes of the D4 POCT have the potential to democratize access to high-performance immunoassays in resource-limited settings without sacrificing their performance.

  5. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.

    PubMed

    Jones, Graham R D; Jackson, Craig

    2016-01-30

    The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Estimation of adhesive bond strength in laminated safety glass using guided mechanical waves

    NASA Astrophysics Data System (ADS)

    Huo, Shihong

    Laminated safety glass is used in the automobile industry and in architectural applications. Laminated safety glass consists of a plastic interlayer, such as a layer of poly vinyl butyral (PVB) or Butacite, surrounded by two adjacent glass plates. The glass can be float glass, plate glass, tempered glass, or sheet glass, and the plastic interlayer is made of a viscoelastic material with relatively high damping. The level of adhesive bond strength between the plastic interlayer and the two adjacent glass plates has a significant role in the penetration resistance against flying objects and is a critical parameter towards ensuring the proper performance of safety glass. Therefore, estimation and control of adhesive bond levels in laminated safety glass is a critical issue. There are several destructive testing procedures used to quantify the adhesion level in laminated safety glass. These tests include the tension test, the peel test, the impact test, and the pummel test. All these tests have drawbacks including the pummel test method, which has been the most widely used in industry for over 80 years. The primary drawbacks of the pummel test method are that it is destructive and subjective (i.e., involves individual human judgment), which precludes this method for use as an on-line test method for quality control. Consequently, a quantitative nondestructive testing method to evaluate adhesion levels would be an asset to the laminated safety glass industry. In this study, adhesion levels in laminated safety glass samples, i.e., windshields, have been assessed using the guided mechanical wave method. To study the adhesive bond strength analytically, the imperfect interfaces between the plastic interlayer and the two adjacent glass plates in laminated safety glass are modeled using a bed of longitudinal and shear springs, and their stiffness characteristics are estimated using fracture mechanics and atomic force microscopy (AFM) surface measurements. The atomic force microscopy measurements are used to estimate the contact area at the imperfect interfaces between the plastic interlayer and the two adjacent glass plates for each of the laminates. The spring layers are then embedded in the global matrix method, which is used to predict the guided wave dispersion behavior of the laminated system. Based upon the guided wave energy velocity predictions for each of the laminates with different levels of adhesion, the S0 mode was selected as the most promising for use in nondestructively estimating adhesion levels in laminated safety glass. The predicted energy velocities (obtained using this multilayered model) were validated using guided wave energy velocity experimental measurements. The experimentally obtained velocity measurements are in good agreement with the predicted values. Guided wave attenuation in laminated safety glass is primarily due to the viscoelastic material properties of the PVB plastic interlayer. The attenuation properties of S1 mode were also explored to estimate the adhesive bond strength between the plastic interlayer and the two adjacent glass plates. Results show that the combination of both the energy velocity and attenuation methods has promise towards replacing the pummel test method to estimate the adhesion level in laminated safety glass.

  7. Integrated Disposal Facility FY2011 Glass Testing Summary Report. Erratum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Gary L.

    2016-09-06

    This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

  8. Integrated Disposal Facility FY 2012 Glass Testing Summary Report, Erratum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Gary L.

    2016-09-02

    This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011) The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

  9. Ultrafine Ceramic Grains Embedded in Metallic Glass Matrix: Achieving Superior Wear Resistance via Increase in Both Hardness and Toughness.

    PubMed

    Yang, Lina; Wen, Mao; Dai, Xuan; Cheng, Gang; Zhang, Kan

    2018-05-09

    As structural materials, crystalline or metallic glass materials have attracted scientific and practical interests. However, some mechanisms involving critical size and shear bands have adverse effects on their mechanical properties. Here, we counter these two effects by introducing a special structure with ultrafine ceramic grains (with a diameter of ∼2.0 nm) embedded into a metallic glass matrix, wherein the grains are mainly composed of a Ta-W-N solid solution structure in nature, surrounded by a W-based amorphous matrix that contains Ta and N atoms. Such a structure is in situ formed during preparation, which combines the merits of both phases to achieve simultaneous increase in hardness and toughness relative to references (pure TaN and W) and thus superior wear resistance. Even more remarkable, a favorable variation of increased hardness but reduced elasticity modulus can be induced by this structure. Intrinsically, ultrafine ceramic grains (free of dislocations), embedded in the metallic glass matrix, could prevent shear band propagation within the glass matrix and further improve the hardness of the matrix material. In return, such glass matrix allows for stiffness neutralization and structural relaxation to reduce the elasticity modulus of ceramic grains. This study will offer a new guidance to fabricate ultrahigh-performance metal-based composites.

  10. Selected Bibliography on Fiber-Reinforced Cement and Concrete. Supplement number 1.

    DTIC Science & Technology

    1977-09-01

    A listing of 156 additional references with author index is given for fiber-reinforced cement and gypsum matrices, mortars, and concretes. Fiber types include steel, glass, plastic, asbestos, organic, carbon, and others. (Author)

  11. Selected Bibliography on Fiber-Reinforced Cement and Concrete. Supplement Number 2.

    DTIC Science & Technology

    1979-07-01

    A listing of 471 additional references with author index is given for fiber-reinforced cement and gypsum matrices, mortars, and concretes. Fiber types include steel, glass, plastic, asbestos, organic, carbon, and others. (Author)

  12. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.

    PubMed

    Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow

    2016-04-01

    The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to <19 years of age were recruited from the community. Serum samples were collected for measurement of 29 biomarkers on the Beckman Coulter Immunoassay Systems. Statistically relevant age and/or gender-based partitions were determined, outliers removed, and reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.

  13. External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot collaboration in Europe.

    PubMed

    Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R

    2014-05-15

    Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Phase diagram, correlation gap, and critical properties of the Coulomb glass

    NASA Astrophysics Data System (ADS)

    Palassini, Matteo; Goethe, Martin

    2009-03-01

    We investigate the lattice Coulomb glass model in three dimensions via extensive Monte Carlo simulations. 1. No evidence for an equilibrium glass phase is found down to very low temperatures, contrary to mean-field predictions, although the correlation length increases rapidly near T=0. 2. The single-particle density of states near the Coulomb gap satisfies the scaling law g(e,T)=T^λf(e/T) with λ 2.2. 3. A charge-ordered phase exists at low disorder. The phase transition from the fluid to the charge ordered phase is consistent with the Random Field Ising universality class, which shows that the interaction is effectively screened at moderate temperature. Results from nonequilibrium simulations will also be briefly discussed. Reference: M.Goethe and M.Palassini, arXiv:0810.1047

  15. Access to Elementary Education in India. Country Analytical Review

    ERIC Educational Resources Information Center

    Govinda, R.; Bandyopadhyay, Madhumita

    2008-01-01

    This analytical review aims at exploring trends in educational access and delineating different groups, which are vulnerable to exclusion from educational opportunities at the elementary stage. This review has drawn references from series of analytical papers developed on different themes i.e. regional disparity in education, social equity and…

  16. High-performance organic light-emitting diodes comprising ultrastable glass layers

    PubMed Central

    Rodríguez-Viejo, Javier

    2018-01-01

    Organic light-emitting diodes (OLEDs) are one of the key solid-state light sources for various applications including small and large displays, automotive lighting, solid-state lighting, and signage. For any given commercial application, OLEDs need to perform at their best, which is judged by their device efficiency and operational stability. We present OLEDs that comprise functional layers fabricated as ultrastable glasses, which represent the thermodynamically most favorable and, thus, stable molecular conformation achievable nowadays in disordered solids. For both external quantum efficiencies and LT70 lifetimes, OLEDs with four different phosphorescent emitters show >15% enhancements over their respective reference devices. The only difference to the latter is the growth condition used for ultrastable glass layers that is optimal at about 85% of the materials’ glass transition temperature. These improvements are achieved through neither material refinements nor device architecture optimization, suggesting a general applicability of this concept to maximize the OLED performance, no matter which specific materials are used. PMID:29806029

  17. Effect of the glass transition temperature on alpha-amylase activity in a starch matrix.

    PubMed

    Chaudhary, Vinita; Panyoyai, Naksit; Small, Darryl M; Shanks, Robert A; Kasapis, Stefan

    2017-02-10

    This study optimises a protocol for the estimation of α-amylase activity in a condensed starch matrix in the vicinity of the glass transition region. Enzymatic activity on the vitrified starch system was compared with that of a reference substrate, maltodextrin. The activity was assayed as the rate of release of reducing sugar using a dinitrosalicylic acid procedure. The condensed carbohydrate matrices served the dual purpose of acting as a substrate as well as producing a pronounced effect on the ability to enzymatic hydrolysis. Activation energies were estimated throughout the glass transition region of condensed carbohydrate preparations based on the concept of the spectroscopic shift factor. Results were used to demonstrate a considerable moderation by the mechanical glass transition temperature, beyond the expected linear effect of the temperature dependence, on the reaction rate of starch hydrolysis by α-amylase in comparison with the low-molecular weight chain of maltodextrin. Copyright © 2016. Published by Elsevier Ltd.

  18. Analytical Chemistry: A Literary Approach.

    ERIC Educational Resources Information Center

    Lucy, Charles A.

    2000-01-01

    Provides an anthology of references to descriptions of analytical chemistry techniques from history, popular fiction, and film which can be used to capture student interest and frame discussions of chemical techniques. (WRM)

  19. Semi-analytical integration of the Earth's precession-nutation based on the GCRS coordinates of the CIP unit vector

    NASA Astrophysics Data System (ADS)

    Capitaine, N.; Folgueira, M.

    2012-12-01

    In a previous paper (Capitaine et al. 2006), referred here as Paper I, we demonstrated the possibility of integrating the Earth's rotational motion in terms of the coordinates (X, Y ) of the celestial intermediate pole (CIP) unit vector in the Geocentric celestial reference system (GCRS). Here, we report on the approach that has been followed for solving the equations in the case of an axially symmetric rigid Earth and the semi-analytical (X, Y ) solution obtained from the expression of the external torque acting on the Earth derived from the most complete semi-analytical solutions for the Earth, Moon and planets.

  20. Predicting The Intrusion Layer From Deep Ocean Oil Spills

    NASA Astrophysics Data System (ADS)

    Wang, Dayang; Chow, Aaron; Adams, E. Eric

    2015-11-01

    Oil spills from deep ocean blowout events motivate our study of multiphase plumes in a water column. Key to understanding the long-term fate of these plumes is the ability to predict the depth and persistence of intrusion layers. While intrusion layers from multiphase plumes have been studied under stagnant conditions, their behavior in the presence of crossflow, especially in mild crossflow, remains poorly understood. The classical classification of plume behavior identifies two regimes: crossflow-dominant and stratification-dominant--but it does not account for the interplay between the two effects, leaving the transition region unexplored. We conduct laboratory tank experiments to investigate the behavior of intrusion layers under the simultaneous action of crossflow and stratification. Our experiments use an inverted frame of reference, using glass beads with a range of sizes to simulate oil droplets. We find that crossflow creates enhanced mixing, which in turn leads to a shallower intrusion layer of the released fluid (correspondingly, a deeper layer in the case of a deep ocean blowout). We develop a mathematical formulation that extends previous models to account for crossflow effects, and use field observations to validate the analytical and experimental findings.

  1. Determination of double bond conversion in dental resins by near infrared spectroscopy.

    PubMed

    Stansbury, J W; Dickens, S H

    2001-01-01

    This study determined the validity and practicality of near infrared (NIR) spectroscopic techniques for measurement of conversion in dental resins. Conversion measurements by NIR and mid-IR were compared using two techniques: (1) The conversion of 3mm thick photopolymerized Bis-GMA/TEGDMA resin specimens was determined by transmission NIR. Specimens were then ground and reanalyzed in KBr pellet form by mid-IR. (2) As further verification, thin resin films were photocured and analyzed by mid-IR. Multiple thin films were then compressed into a thick pellet for examination by NIR. Conversion values obtained by NIR and mid-IR techniques did not differ significantly. A correction for changing specimen thickness due to polymerization shrinkage was applied to NIR conversion measurements since an internal standard reference peak was not employed. Sensitivity of the NIR technique was superior to those based on the mid-IR. The nondestructive analysis of conversion in dental resins by NIR offers advantages of convenience, practical specimen dimensions and precision compared with standard mid-IR analytical procedures. Because glass is virtually transparent in the NIR spectrum, this technique has excellent potential for use with filled dental resins as well.

  2. A SEM-ATEM and stable isotope study of carbonates from the Haughton impact crater, Canada

    NASA Astrophysics Data System (ADS)

    Martinez, Isabelle; Agrinier, Pierre; Schärer, Urs; Javoy, Marc

    1994-02-01

    Highly and intermediately shocked carbonate-rich fragments of the allochtonous polymict breccia from the Haughton impact crater (Canada) were studied by Scanning Electron Microscopy (SEM), Analytical Transmission Electron Microscopy (ATEM) and analyses of carbon and oxygen stable isotopes ( δ13C and δ18O). In areas subjected to severe shock conditions, carbonates represent only about 10 vol% of the shocked samples and they are located in holes and fractures within a matrix of SiO 2-rich glass. Shock features are absent in these crystals. High-temperature reactions have occurred between molten silicates and carbonates, producing Ca sbnd Mg-rich glasses, or crystalline phases such as augite and larnite (Ca 2SiO 4). The carbonates are dominated by calcite and they generally have significantly positive δ13C, ranging up to +9‰, with a weighted average value of +1.75‰. Their δ18O values range between +15‰ and +20‰ and they are about 5‰ lower than in unshocked reference sediments, a trend consistent with that resulting from silicate-carbonate reactions. The microstructures of the carbonates suggest that they did not undergo shock conditions but, instead, were produced by back-reactions between impact-released CO 2 and highly reactive residual oxides. Such a process would introduce isotope fractionations, which might explain the positive δ13C values observed. A simple kinetic fractionation model involving a Rayleigh distillation process is used to estimate the CO 2 fraction actually lost from the carbonates. It appears that this fraction is related to the amount of high-temperature carbonate-silicate reactions. Moderately shocked fragments from other areas of the polymict breccia consist of 40-81 vol% carbonates. Their δ13C values lie in the range of unshocked reference sediments between -2‰ and -4‰, whereas their δ18O values are by about 5‰ lower than in the unshocked equivalents. No evidence for important decarbonatization is observed from 13C, and 18O is again buffered by isotope exchange reactions between molten silicates and carbonate crystals producing Ca and Mg enriched SiO 2 glass and Ca sbnd Mg silicate crystals such as monoclinic pigeonite, which is indicative of fast cooling. This study indicates that significant evidence for outgassing is limited to a narrow zone in the centre of the crater, where peak shock pressures reached 50-60 GPa. Moreover, we suggest that, within this area, a large fraction of the shock-produced gas recombines with the highly reactive residual oxides and, in consequence, that such back-reactions might be a general mechanism for retaining impact-produced volatiles during impact events.

  3. In vitro fluoride release from a different kind of conventional and resin modified glass-ionomer cements

    PubMed Central

    Selimović-Dragaš, Mediha; Hasić-Branković, Lajla; Korać, Fehim; Đapo, Nermin; Huseinbegović, Amina; Kobašlija, Sedin; Lekić, Meliha; Hatibović-Kofman, Šahza

    2013-01-01

    Fluoride release is important characteristic of glass-ionomer cements. Quantity of fluoride ions released from the glass-ionomer cements has major importance in definition of their biological activity. The objectives of this study were to define the quantity of fluoride ions released from the experimental glass-ionomer cements and to define the effect of fluoride ions released from the experimental glass-ionomer cements on their cytotoxicity. Concentrations of the fluoride ions released in the evaluated glass-ionomer cements were measured indirectly, by the fluoride-selective WTW, F500 electrode potential, combined with reference R503/D electrode. Statistical analyses of F-ion concentrations released by all glass-ionomers evaluated at two time points, after 8 and after 24 hours, show statistically higher fluoride releases from RMGICs: Vitrebond, Fuji II LC and Fuji Plus, when compared to conventional glass-ionomer cements: Fuji Triage, Fuji IX GP Fast and Ketac Silver, both after 8 and after 24 hours. Correlation coefficient between concentrations of fluoride ion released by evaluated glass-ionomer cements and cytotoxic response of UMR-106 osteoblast cell-line are relatively high, but do not reach levels of biological significance. Correlation between concentrations of fluoride ion released and cytotoxic response of NIH3T3 mouse fibroblast cell line after 8 hours is high, positive and statistically significant for conventional GICs, Fuji Triage and Fuji IX GP Fast, and RMGIC, Fuji II LC. Statistically significant Correlation coefficient between concentrations of fluoride ion released and cytotoxic response of NIH3T3 cell line after 24 hours is defined for RMGIC Fuji II LC only. PMID:23988173

  4. Evaluation of the surface strength of glass plates shaped by hot slumping process

    NASA Astrophysics Data System (ADS)

    Proserpio, L.; Crimi, G.; Ghigo, M.; Pareschi, G.; Salmaso, B.; D'Este, A.; Dall'Igna, R.; Silvestri, M.; Parodi, G.; Martelli, F.

    2013-09-01

    The Hot Slumping Technology is under development by several research groups in the world for the realization of X-ray segmented mirrors, based on thin glass plates: during the process of slumping, a glass foil is shaped over a mould at temperatures above its transformation point. The performed thermal cycle and related operations might have effects on the strength characteristics of the glass, with consequences on the structural design of the elemental optical module and consecutively on the whole X-ray telescope. No reference technical literature exists for this particular aspect since the strength of glass depends on several parameters connected to any of the manufacturing and glass history stages, such as the distribution of surface flaws or the residual internal stresses. It is therefore extremely important to test the mechanical strength of the glass plates after they underwent the slumping process. The Astronomical Observatory of Brera (INAFOAB, Merate - Italy) started a deep analysis of this aspect, with the collaboration of Stazione Sperimentale del Vetro (SSV, Murano - Italy) and BCV Progetti (Milano - Italy). The entire study has been realized on borosilicate glass D263 by Schott, largely considered for the realization of next-generation IXO-like X-ray telescope. More than 200 slumped plates of dimension 100 mm x 100 mm and thickness 0.4 mm, both flat and curved, have been produced and tested; the collected experimental data have been compared to non-linear FEM analyses and treated with Weibull statistics, giving the strength data necessary to assess the current IXO glass X-ray telescope design, in terms of survival probability, when subject to static and acoustic load characteristic of the launch phase. The paper describes the activities performed and presents the obtained results.

  5. Spectral analysis of Cu 2+: B 2O 3-ZnO-PbO glasses

    NASA Astrophysics Data System (ADS)

    Lakshminarayana, G.; Buddhudu, S.

    2005-11-01

    A new series of heavy metal oxide (PbO) based zinc borate glasses in the chemical composition of (95 - x)B 2O 3-5ZnO- xPbO ( x = 10, 15, 20, 25, 30, 35, 40, 45 and 50 mol%) have been prepared to verify their UV filtering performance. Both direct and indirect optical band gaps ( Eopt) have been evaluated for these glasses. For a reference glass of 45B 2O 3-5ZnO-50PbO, refractive indices at different wavelengths are measured and found the results satisfactorily correlated with the theoretical data upon the computation of Cauchy's constants of A = 1.766029949, B = 159531.024 nm 2 and C = -1.078 × 10 10 nm 4. Measurements concerning X-ray diffraction (XRD), FT-IR, differential scanning colorimeter (DSC) profiles have been carried out for this glass. The FT-IR profile has revealed that the glass has both BO 3 and BO 4 units. From DSC thermogram, glass transition temperature ( Tg), crystallization temperature ( Tc) and melting temperature ( Tm) have been located and from them, other related parameters of the glass have also been calculated. Visible absorption spectra of 45B 2O 3-5ZnO-(50 - x)PbO- xCuO ( x = 0. 1, 0.2, 0.5 and 1.0 mol%) have revealed two absorption bands at around 400 nm ( 2B 1g → 2E g) and 780 nm ( 2B 1g → 2B 2g) of Cu 2+ ions, respectively. Emission bands at 422 and 512 nm are found for the 1 mol% CuO doped glass with excitations at 306 and 332 nm.

  6. The Controversial Role of Inter-diffusion in Glass Alteration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gin, Stephane; Neill, Lindsay; Fournier, M.

    2016-11-15

    Current kinetic models for nuclear waste glasses (e.g. GM2001, GRAAL) are based on a set of mechanisms that have been generally agreed upon within the international waste glass community. These mechanisms are: hydration of the glass, ion exchange reactions (the two processes are referred as inter-diffusion), hydrolysis of the silicate network, and condensation/precipitation of partly or completely hydrolyzed species that produces a porous and amorphous layer and crystalline phases on surface of the altered glass. Recently, a new idea with origins in the mineral dissolution community has been proposed that excludes inter-diffusion process as a potential rate-limiting mechanism. To understandmore » how the so-called interfacial dissolution/precipitation model can change the current understanding of glass behavior, a key experiment used to account for this model was replicated to further revisit the interpretation. This experiment was performed at 50°C, with SON68 glass, in static mode, deionized water and S/V ratio of 10 m-1 for 6 months. It turn out that glass alters in an intermediate kinetic regime between the forward and the residual rate. According to previous and new solid characterizations, it is concluded that neither a simple inter-diffusion model nor the interfacial dissolution precipitation model can account for the observed elemental profiles within the alteration layer. More generally, far and close-to-saturation conditions must be distinguished and literature provides evidences that inter-diffusion takes place in slightly acidic conditions and far from saturation. However, closer to saturation, when a sufficiently dense layer is formed, a new approach is proposed requiring a full description of chemical reactions taking place within the alteration layer and involving water molecules as it is thought that water accessibility to the pristine glass is the rate-limiting process.« less

  7. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    PubMed

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Implementation and Use of the Reference Analytics Module of LibAnswers

    ERIC Educational Resources Information Center

    Flatley, Robert; Jensen, Robert Bruce

    2012-01-01

    Academic libraries have traditionally collected reference statistics using hash marks on paper. Although efficient and simple, this method is not an effective way to capture the complexity of reference transactions. Several electronic tools are now available to assist libraries with collecting often elusive reference data--among them homegrown…

  9. Integration of paper-based microarray and time-of-flight secondary ion mass spectrometry (ToF-SIMS) for parallel detection and quantification of molecules in multiple samples automatically.

    PubMed

    Chu, Kuo-Jui; Chen, Po-Chun; You, Yun-Wen; Chang, Hsun-Yun; Kao, Wei-Lun; Chu, Yi-Hsuan; Wu, Chen-Yi; Shyue, Jing-Jong

    2018-04-16

    With its low-cost fabrication and ease of modification, paper-based analytical devices have developed rapidly in recent years. Microarrays allow automatic analysis of multiple samples or multiple reactions with minimal sample consumption. While cellulose paper is generally used, its high backgrounds in spectrometry outside of the visible range has limited its application to be mostly colorimetric analysis. In this work, glass-microfiber paper is used as the substrate for a microarray. The glass-microfiber is essentially chemically inert SiO x , and the lower background from this inorganic microfiber can avoid interference from organic analytes in various spectrometers. However, generally used wax printing fails to wet glass microfibers to form hydrophobic barriers. Therefore, to prepare the hydrophobic-hydrophilic pattern, the glass-microfiber paper was first modified with an octadecyltrichlorosilane (OTS) self-assembled monolayer (SAM) to make the paper hydrophobic. A hydrophilic microarray was then prepared using a CO 2 laser scriber that selectively removed the OTS layer with a designed pattern. One microliter of aqueous drops of peptides at various concentrations were then dispensed inside the round patterns where OTS SAM was removed while the surrounding area with OTS layer served as a barrier to separate each drop. The resulting specimen of multiple spots was automatically analyzed with a time-of-flight secondary ion mass spectrometer (ToF-SIMS), and all of the secondary ions were collected. Among the various cluster ions that have developed over the past decade, pulsed C 60 + was selected as the primary ion because of its high secondary ion intensity in the high mass region, its minimal alteration of the surface when operating within the static-limit and spatial resolution at the ∼μm level. In the resulting spectra, parent ions of various peptides (in the forms [M+H] + and [M+Na] + ) were readily identified for parallel detection of molecules in a mixture. By normalizing the ion intensity of peptides with respect to the glass-microfiber matrix ([SiOH] + ), a linear calibration curve for each peptide was generated to quantify these components in a mixture. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    NASA Astrophysics Data System (ADS)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  11. A global multicenter study on reference values: 1. Assessment of methods for derivation and comparison of reference intervals.

    PubMed

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K

    2017-04-01

    The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Pediatric reference intervals for random urine calcium, phosphorus and total protein.

    PubMed

    Slev, Patricia R; Bunker, Ashley M; Owen, William E; Roberts, William L

    2010-09-01

    The aim of this study was to establish age appropriate reference intervals for calcium (Ca), phosphorus (P) and total protein (UTP) in random urine samples. All analytes were measured using the Roche MODULAR P analyzer and normalized to creatinine (Cr). Our study cohort consisted of 674 boys and 728 girls between 7 and 17 years old (y.o.), which allowed us to determine the central 95% reference intervals with 90% confidence intervals by non-parametric analysis partitioned by both gender and 2-year age intervals for each analyte [i.e. boys in age group 7-9 years (7-9 boys); girls in age group 7-9 years (7-9 girls), etc.]. Results for the upper limits of the central 95% reference interval were: for Ca/Cr, 0.27 (16,17 y.o.) to 0.46 mg/mg (7-9 y.o.) for the girls and 0.26 (16,17 y.o.) to 0.43 mg/mg (7-9 y.o.) for the boys; for P/Cr, 0.85 (16,17 y.o.) to 1.44 mg/mg (7-9 y.o.) for the girls and 0.87 (16,17 y.o.) to 1.68 mg/mg (7-9 y.o.) for the boys; for UTP/Cr, 0.30 (7-9 y.o.) to 0.34 mg/mg (10-12 y.o.) for the girls and 0.19 (16,17, y.o.) to 0.26 mg/mg (13-15 y.o.) for the boys. Upper reference limits decreased with increasing age, and age was a statistically significant variable for all analytes. Eight separate age- and gender-specific reference intervals are proposed per analyte.

  13. Post-Decontamination Vapor Sampling and Analytical Test Methods

    DTIC Science & Technology

    2015-08-12

    construction materials (e.g., acrylic, stainless steel , glass, etc.) for containing the chemical contaminants, coupons, coupon holders, and decontaminant(s...made of inert materials, e.g., stainless steel , T6061 aluminum, or equivalent. The construction material may be treated to further minimize...include glove ports. The chamber may have certified fume hoods for the containment of toxic chemicals. All exhaust air must be filtered to

  14. Manufacturing Methods and Technology for Microwave Stripline Circuits

    DTIC Science & Technology

    1982-02-26

    to the dielectric material so It does not peel during the etching and subsequent processing. The copper cladding requirements were defined by MIL-F...the B-stage,giv- ing acceptable peel strengths per the military requirements. For PTFE sub- strata printed wiring boards that are laminated using a...examining multilayers for measles and delaminations, and analytically by performing peel tests and glass transition temperatures. "STRIPLINE

  15. Crystal Nucleation and Growth in Undercooled Melts of Pure Zr, Binary Zr-Based and Ternary Zr-Ni-Cu Glass-Forming Alloys

    NASA Astrophysics Data System (ADS)

    Herlach, Dieter M.; Kobold, Raphael; Klein, Stefan

    2018-03-01

    Glass formation of a liquid undercooled below its melting temperature requires the complete avoidance of crystal nucleation and subsequent crystal growth. Even though they are not part of the glass formation process, a detailed knowledge of both processes involved in crystallization is mandatory to determine the glass-forming ability of metals and metallic alloys. In the present work, methods of containerless processing of drops by electrostatic and electromagnetic levitation are applied to undercool metallic melts prior to solidification. Heterogeneous nucleation on crucible walls is completely avoided giving access to large undercoolings. A freely suspended drop offers the additional benefit of showing the rapid crystallization process of an undercooled melt in situ by proper diagnostic means. As a reference, crystal nucleation and dendrite growth in the undercooled melt of pure Zr are experimentally investigated. Equivalently, binary Zr-Cu, Zr-Ni and Zr-Pd and ternary Zr-Ni-Cu alloys are studied, whose glass-forming abilities differ. The experimental results are analyzed within classical nucleation theory and models of dendrite growth. The findings give detailed knowledge about the nucleation-undercooling statistics and the growth kinetics over a large range of undercooling.

  16. Cavitation and pore blocking in nanoporous glasses.

    PubMed

    Reichenbach, C; Kalies, G; Enke, D; Klank, D

    2011-09-06

    In gas adsorption studies, porous glasses are frequently referred to as model materials for highly disordered mesopore systems. Numerous works suggest that an accurate interpretation of physisorption isotherms requires a complete understanding of network effects upon adsorption and desorption, respectively. The present article deals with nitrogen and argon adsorption at different temperatures (77 and 87 K) performed on a series of novel nanoporous glasses (NPG) with different mean pore widths. NPG samples contain smaller mesopores and significantly higher microporosity than porous Vycor glass or controlled pore glass. Since the mean pore width of NPG can be tuned sensitively, the evolution of adsorption characteristics with respect to a broadening pore network can be investigated starting from the narrowest nanopore width. With an increasing mean pore width, a H2-type hysteresis develops gradually which finally transforms into a H1-type. In this connection, a transition from a cavitation-induced desorption toward desorption controlled by pore blocking can be observed. Furthermore, we find concrete hints for a pore size dependence of the relative pressure of cavitation in highly disordered pore systems. By comparing nitrogen and argon adsorption, a comprehensive insight into adsorption mechanisms in novel disordered materials is provided. © 2011 American Chemical Society

  17. The glass cliff: when and why women are selected as leaders in crisis contexts.

    PubMed

    Bruckmüller, Susanne; Branscombe, Nyla R

    2010-09-01

    The glass cliff refers to women being more likely to rise to positions of organizational leadership in times of crisis than in times of success, and men being more likely to achieve those positions in prosperous times. We examine the role that (a) a gendered history of leadership and (b) stereotypes about gender and leadership play in creating the glass cliff. In Expt 1, participants who read about a company with a male history of leadership selected a male future leader for a successful organization, but chose a female future leader in times of crisis. This interaction--between company performance and gender of the preferred future leader--was eliminated for a counter-stereotypic history of female leadership. In Expt 2, stereotypically male attributes were most predictive of leader selection in a successful organization, while stereotypically female attributes were most predictive in times of crisis. Differences in the endorsement of these stereotypes, in particular with regard to the ascription of lower stereotypically female attributes to the male candidate mediated the glass cliff effect. Overall, results suggest that stereotypes about male leadership may be more important for the glass cliff effect than stereotypes about women and leadership.

  18. Homogeneity testing and quantitative analysis of manganese (Mn) in vitrified Mn-doped glasses by laser-induced breakdown spectroscopy (LIBS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unnikrishnan, V. K.; Nayak, Rajesh; Kartha, V. B.

    2014-09-15

    Laser-induced breakdown spectroscopy (LIBS), an atomic emission spectroscopy method, has rapidly grown as one of the best elemental analysis techniques over the past two decades. Homogeneity testing and quantitative analysis of manganese (Mn) in manganese-doped glasses have been carried out using an optimized LIBS system employing a nanosecond ultraviolet Nd:YAG laser as the source of excitation. The glass samples have been prepared using conventional vitrification methods. The laser pulse irradiance on the surface of the glass samples placed in air at atmospheric pressure was about 1.7×10{sup 9} W/cm{sup 2}. The spatially integrated plasma emission was collected and imaged on tomore » the spectrograph slit using an optical-fiber-based collection system. Homogeneity was checked by recording LIBS spectra from different sites on the sample surface and analyzing the elemental emission intensities for concentration determination. Validation of the observed LIBS results was done by comparison with scanning electron microscope- energy dispersive X-ray spectroscopy (SEM-EDX) surface elemental mapping. The analytical performance of the LIBS system has been evaluated through the correlation of the LIBS determined concentrations of Mn with its certified values. The results are found to be in very good agreement with the certified concentrations.« less

  19. Gallium-containing phosphosilicate glasses: functionalization and in-vitro bioactivity.

    PubMed

    Lusvardi, Gigliola; Malavasi, Gianluca; Menabue, Ledi; Shruti, Shruti

    2013-08-01

    A gallium containing glass 45.7SiO2·24.1Na2O·26.6CaO·2.6P2O5·1.0Ga2O3 (referred to as "Ga1.0") and a parent Ga-free glass 46.2SiO2·24.3Na2O·26.9CaO·2.6P2O5 (hereinafter represented as "H"), corresponding to Bioglass® 45S5, were functionalized with Tetraethoxysilane (TEOS) and (3-Aminopropyl)triethoxysilane (APTS) in order to improve their ability to bond with biomolecules, such as drugs, proteins, and peptides. Functionalization with TEOS and APTS promoted the increment in OH groups and formation of NH2 groups on the glass surface, respectively. The presence of OH or NH2 groups was investigated by means of IR spectroscopy and elemental analysis. Moreover, in vitro study of these functionalized glasses was performed in simulated body fluid (SBF) so as to investigate the effect of functionalization on the bioactive behavior of H and Ga1.0. The results showed that the functionalization was obtained along with maintaining their bioactivity. The surfaces of both functionalized glasses were covered by a layer of apatite within 30 days of SBF immersion. In addition, CaCO3 was also identified on the surface of APTS functionalized glasses. However, no gallium release was detected during SBF soaking. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Connectivity of glass structure. Oxygen number

    NASA Astrophysics Data System (ADS)

    Medvedev, E. F.; Min'ko, N. I.

    2018-03-01

    With reference to mathematics, crystal chemistry and chemical technology of synthesis of glass structures in the solution (sol-gel technology), the paper is devoted to the study of the degree of connectivity of a silicon-oxygen backbone (fSi) and the oxygen number (R) [1]. It reveals logical contradictions and uncertainty of mathematical expressions of parameters, since fSi is not similar to the oxygen number. The connectivity of any structure is a result of various types of bonds: ion-covalent, donor-acceptor, hydrogen bonds, etc. Besides, alongside with SiO2, many glass compositions contain other glass-forming elements due to tetrahedral sites thus formed. The connectivity function of a glassy network with any set of glass-forming elements is roughly ensured by connectivity factor Y [2], which has monovalent elements loosening a glassy network. The paper considers the existence of various structural motives in hydrogen-impermeable glasses containing B2O3, Al2O3, PbO, Na2O, K2O and rare-earth elements. Hence, it also describes gradual nucleation, change of crystal forms, and structure consolidation in the process of substance intake from a matrix solution according to sol-gel technology. The crystal form varied from two-dimensional plates to three-dimensional and dendritical ones [3]. Alternative parameters, such as the oxygen number (O) and the structure connectivity factor (Y), were suggested. Functional dependence of Y=f(O) to forecast the generated structures was obtained for two- and multicomponent glass compositions.

  1. Grinding aspheric and freeform micro-optical molds

    NASA Astrophysics Data System (ADS)

    Tohme, Yazid E.

    2007-02-01

    Fueled by the need for better performing optics, glass optics are now replacing plastic optics in many industrial and consumer electronic devices. One of these devices is the mobile phone camera. The optical sub-assembly in a mobile phone includes several micro lenses that are spherical and/or aspherical in shape and require form tolerances in the submicron range. These micro glass lenses are mass produced by a replication process known as glass press molding. The process entails the compression of a glass gob between two precise optical quality molds at an elevated temperature, usually near the transition temperature of the glass material. The elevated forces and temperatures required in the glass molding process limits the materials of the molds to very tough materials such as tungsten carbide or silicon carbide. These materials can withstand large pressing forces at high temperatures without any significant deformation. These materials offer great mechanical properties for glass press molding but they are also a challenge to machine to submicron accuracy. The work in this paper discusses a deterministic micro grinding manufacturing process referred to as wheel normal grinding, which is utilized to produce these optical quality molds. Wheel normal grinding is more accurate and more deterministic than most other grinding techniques and can produce molds to the form and finish tolerances required for optical molding. This method relies on the ability to recognize and compensate for grinding wheel wear and machine repeatable errors. Results will be presented to illustrate the accuracy of this micro grinding technique.

  2. Introducing Text Analytics as a Graduate Business School Course

    ERIC Educational Resources Information Center

    Edgington, Theresa M.

    2011-01-01

    Text analytics refers to the process of analyzing unstructured data from documented sources, including open-ended surveys, blogs, and other types of web dialog. Text analytics has enveloped the concept of text mining, an analysis approach influenced heavily from data mining. While text mining has been covered extensively in various computer…

  3. The Role of a Reference Synthetic Data Generator within the Field of Learning Analytics

    ERIC Educational Resources Information Center

    Berg, Alan\tM.; Mol, Stefan T.; Kismihók, Gábor; Sclater, Niall

    2016-01-01

    This paper details the anticipated impact of synthetic "big" data on learning analytics (LA) infrastructures, with a particular focus on data governance, the acceleration of service development, and the benchmarking of predictive models. By reviewing two cases, one at the sector-wide level (the Jisc learning analytics architecture) and…

  4. Surface temperature determination in surface analytic systems by infrared optical pyrometry

    NASA Technical Reports Server (NTRS)

    Wheeler, Donald R.; Jones, William R., Jr.; Pepper, Stephen V.

    1988-01-01

    An IR pyrometric technique for measuring the surface temperatures of metal specimens in an ultrahigh-vacuum analytic chamber is described and demonstrated. The experimental setup comprises a commercial IR microscope with a long-working-distance right-angle objective (focal spot diameter 1 mm at 53 cm), a metal-coated glass vacuum chamber with a Ta-mesh-covered quartz viewport, an Mo specimen stub with an internal heating element, and a Ta disk test specimen with a flat side coated with a high-emissivity graphite film. The results of an initial calibration test are presented graphically and briefly characterized. The measurement error at 450 C is found to be less than 10 C.

  5. A compilation of whole-rock and glass major-element geochemistry of Kilauea Volcano, Hawai'i, near-vent eruptive products: January 1983 through September 2001

    USGS Publications Warehouse

    Thornber, Carl R.; Hon, Ken; Heliker, Christina; Sherrod, David A.

    2003-01-01

    This report presents major-element geochemical data from 652 glasses (~6,520 analyses) and 795 whole-rock aliquots from 1,002 fresh samples of olivine-tholeiitic lava collected throughout the near-continuous eruption of Kïlauea Volcano, Hawai'i, from January 1983 through September 2001. The data presented herein provide a unique temporal compilation of lava geochemistry that best reflects variations of pre-eruptive magma compositions during prolonged rift-zone eruption. This document serves as a repository for geochemical data referred to in U.S. Geological Survey Professional Paper 1676 (Heliker, Swanson, and Takahashi, eds., 2003) which includes multidisciplinary research papers pertaining to the first twenty years of Puu Oo-Kupaianaha eruption activity. Details of eruption characteristics and nomenclature are provided in the introductory chapter of that volume (Heliker and Mattox, 2003). Geochemical relations among all or portions of this data set are depicted and interpreted by Thornber (2003), Thornber and others (2003) and Thornber (2001). Trace element compositions and Nd, Sr and Pb isotopic analyses of representative samples of this select eruption suite will be provided in a separate and complimentary open file report. From 1983 to October 2001, approximately 2,500 eruption samples were collected and archived by the U.S. Geological Survey’s Hawaiian Volcano Observatory (HVO). Geochemical data for 1,002 of these samples are included here. Previous reports present bulk-lava major- element chemistry for eruption samples collected from 1983 to 1986 and from 1990 to 1994 (Neal and others, 1988 and Mangan and others, 1995, respectively). Major element glass chemistry and thermometry data for samples collected from 1983 to 1994 is reported by Helz and Hearn (1998) and whole-rock and glass chemistry for samples collected from September 1994 to October 2001 is provided by Thornber and others (2002). This report is a compilation of previously published data along with unpublished whole-rock data for the 1986–1990 eruptive interval (episode 48, see Heliker and Mattox, 2003). The geochemical data in this report is mostly limited to well-quenched samples collected at or near their respective vents. The samples include tephra and spatter, in addition to lava dipped from lava lakes, lava tubes, and surface lava flows. The details of sample collection techniques as described by Thornber and others (2002) are generally applicable for this entire sampling interval. Specifically excluded from this database are samples of distal surface flows, many of which were collected for topical studies of emplacement dynamics (for example, Cashman and others, 1999). Samples of sluggish or crystal-laden tube flows collected during eruptive pauses were also excluded, because they bear visual, petrographic and geochemical evidence for crystal accumulation during surface-flow stagnation. In addition, the pre-1992 whole-rock major element data reported here has been corrected to compensate for minor analytical discrepancies between pre- and post-1991 XRF analyses. These discrepancies resulted from a change in instrumentation at the USGS Denver analytical laboratories. This select suite of time-constrained geochemical data is suitable for constructing petrologic models of pre-eruptive magmatic processes associated with prolong rift zone eruption of Hawaiian shield volcanoes.

  6. Numerical and Experimental Investigations on Mechanical Behavior of Composite Corrugated Core

    NASA Astrophysics Data System (ADS)

    Dayyani, Iman; Ziaei-Rad, Saeed; Salehi, Hamid

    2012-06-01

    Tensile and flexural characteristics of corrugated laminate panels were studied using numerical and analytical methods and compared with experimental data. Prepreg laminates of glass fiber plain woven cloth were hand-laid by use of a heat gun to ease the creation of the panel. The corrugated panels were then manufactured by using a trapezoidal machined aluminium mould. First, a series of simple tension tests were performed on standard samples to evaluate the material characteristics. Next, the corrugated panels were subjected to tensile and three-point bending tests. The force-displacement graphs were recorded. Numerical and analytical solutions were proposed to simulate the mechanical behavior of the panels. In order to model the energy dissipation due to delamination phenomenon observed in tensile tests in all members of corrugated core, plastic behavior was assigned to the whole geometry, not only to the corner regions. Contrary to the literature, it is shown that the three-stage mechanical behavior of composite corrugated core is not confined to aramid reinforced corrugated laminates and can be observed in other types such as fiber glass. The results reveal that the mechanical behavior of the core in tension is sensitive to the variation of core height. In addition, for the first time, the behavior of composite corrugated core was studied and verified in bending. Finally, the analytical and numerical results were validated by comparing them with experimental data. A good degree of correlation was observed which showed the suitability of the finite element model for predicting the mechanical behavior of corrugated laminate panels.

  7. Endotoxin removal by radio frequency gas plasma (glow discharge)

    NASA Astrophysics Data System (ADS)

    Poon, Angela

    2011-12-01

    Contaminants remaining on implantable medical devices, even following sterilization, include dangerous fever-causing residues of the outer lipopolysaccharide-rich membranes of Gram-negative bacteria such as the common gut microorganism E. coli. The conventional method for endotoxin removal is by Food & Drug Administration (FDA)-recommended dry-heat depyrogenation at 250°C for at least 45 minutes, an excessively time-consuming high-temperature technique not suitable for low-melting or heat-distortable biomaterials. This investigation evaluated the mechanism by which E. coli endotoxin contamination can be eliminated from surfaces during ambient temperature single 3-minute to cumulative 15-minute exposures to radio-frequency glow discharge (RFGD)-generated residual room air plasmas activated at 0.1-0.2 torr in a 35MHz electrodeless chamber. The main analytical technique for retained pyrogenic bio-activity was the Kinetic Chromogenic Limulus Amebocyte Lysate (LAL) Assay, sufficiently sensitive to document compliance with FDA-required Endotoxin Unit (EU) titers less than 20 EU per medical device by optical detection of enzymatic color development corresponding to < 0.5 EU/ml in sterile water extracts of each device. The main analytical technique for identification of chemical compositions, amounts, and changes during sequential reference Endotoxin additions and subsequent RFGD-treatment removals from infrared (IR)-transparent germanium (Ge) prisms was Multiple Attenuated Internal Reflection (MAIR) infrared spectroscopy sensitive to even monolayer amounts of retained bio-contaminant. KimaxRTM 60 mm x 15 mm and 50mm x 15mm laboratory glass dishes and germanium internal reflection prisms were inoculated with E. coli bacterial endotoxin water suspensions at increments of 0.005, 0.05, 0.5, and 5 EU, and characterized by MAIR-IR spectroscopy of the dried residues on the Ge prisms and LAL Assay of sterile water extracts from both glass and Ge specimens. The Ge prism MAIR-IR measurements were repeated after employing 3-minute RFGD treatments sequentially for more than 10 cycles to observe removal of deposited matter that correlated with diminished EU titers. The results showed that 5 cycles, for a total exposure time of 15 minutes to low-temperature gas plasma, was sufficient to reduce endotoxin titers to below 0.05 EU/ml, and correlated with concurrent reduction of major endotoxin reference standard absorption bands at 3391 cm-1, 2887 cm-1, 1646 cm -1 1342 cm-1, and 1103 cm-1 to less than 0.05 Absorbance Units. Band depletion varied from 15% to 40% per 3-minute cycle of RFGD exposure, based on peak-to-peak analyses. In some cases, 100% of all applied biomass was removed within 5 sequential 3-minute RFGD cycles. The lipid ester absorption band expected at 1725 cm-1 was not detectable until after the first RFGD cycle, suggesting an unmasking of the actual bacterial endotoxin membrane induced within the gas plasma environment. Future work must determine the applicability of this low-temperature, quick depyrogenation process to medical devices of more complicated geometry than the flat surfaces tested here.

  8. A critical evaluation of the Beckman Coulter Access hsTnI: Analytical performance, reference interval and concordance.

    PubMed

    Pretorius, Carel J; Tate, Jillian R; Wilgen, Urs; Cullen, Louise; Ungerer, Jacobus P J

    2018-05-01

    We investigated the analytical performance, outlier rate, carryover and reference interval of the Beckman Coulter Access hsTnI in detail and compared it with historical and other commercial assays. We compared the imprecision, detection capability, analytical sensitivity, outlier rate and carryover against two previous Access AccuTnI assay versions. We established the reference interval with stored samples from a previous study and compared the concordances and variances with the Access AccuTnI+3 as well as with two commercial assays. The Access hsTnI had excellent analytical sensitivity with the calibration slope 5.6 times steeper than the Access AccuTnI+3. The detection capability was markedly improved with the SD of the blank 0.18-0.20 ng/L, LoB 0.29-0.33 ng/L and LoD 0.58-0.69 ng/L. All the reference interval samples had a result above the LoB value. At a mean concentration of 2.83 ng/L the SD was 0.28 ng/L (CV 9.8%). Carryover (0.005%) and outlier (0.046%) rates were similar to the Access AccuTnI+3. The combined male and female 99th percentile reference interval was 18.2 ng/L (90% CI 13.2-21.1 ng/L). Concordance amongst the assays was poor with only 16.7%, 19.6% and 15.2% of samples identified by all 4 assays as above the 99th, 97.5th and 95th percentiles. Analytical imprecision was a minor contributor to the observed variances between assays. The Beckman Coulter Access hsTnI assay has excellent analytical sensitivity and precision characteristics close to zero. This allows cTnI measurement in all healthy individuals and the capability to identify numerically small differences between serial samples as statistically significant. Concordance in healthy individuals remains poor amongst assays. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  9. The thermo-optical behavior of turbid composite laminates under highly energetic laser irradiations

    NASA Astrophysics Data System (ADS)

    Allheily, Vadim; Merlat, Lionel; Lacroix, Fabrice; Eichhorn, Alfred; L'Hostis, Gildas

    2017-01-01

    From their prior emergence in the military domain but also nowadays in the civilian area, unmanned air vehicles constitute a growing threat to the todays civilization. In this respect, novel laser weapons are considered to eradicate this menace and the vulnerability of typical aeronautic materials under 1.07μm-wavelength irradiations is also investigated. In this paper, Kubelka-Munk optical parameters of laminated glass fiber-reinforced plastic composites are first assessed to build up a basic analytical interaction model involving internal refraction and reflection as well as the scattering effect due to the presence of glass fibers. Moreover, a thermo-gravimetric analysis is carried out and the kinetic parameters of the decomposition reaction extracted from this test with the Friedman method are verified trough a comparison with experimental measurements.

  10. Cluster-Glass Phase in Pyrochlore X Y Antiferromagnets with Quenched Disorder

    NASA Astrophysics Data System (ADS)

    Andrade, Eric C.; Hoyos, José A.; Rachel, Stephan; Vojta, Matthias

    2018-03-01

    We study the impact of quenched disorder (random exchange couplings or site dilution) on easy-plane pyrochlore antiferromagnets. In the clean system, order by disorder selects a magnetically ordered state from a classically degenerate manifold. In the presence of randomness, however, different orders can be chosen locally depending on details of the disorder configuration. Using a combination of analytical considerations and classical Monte Carlo simulations, we argue that any long-range-ordered magnetic state is destroyed beyond a critical level of randomness where the system breaks into magnetic domains due to random exchange anisotropies, becoming, therefore, a glass of spin clusters, in accordance with the available experimental data. These random anisotropies originate from off-diagonal exchange couplings in the microscopic Hamiltonian, establishing their relevance to other magnets with strong spin-orbit coupling.

  11. Superexchange and spin-glass formation in semimagnetic semiconductors

    NASA Astrophysics Data System (ADS)

    Rusin, Tomasz M.

    1996-05-01

    The Mn-Mn superexchange interaction in semimagnetic semiconductors A1-xMnxB (where A=Zn, Cd and B=S, Se, Te) is studied within the three-level model of the band structure. We focus on the dependence of the interaction on the interion distance Jdd(r)=J0f(r). In the present work, the function f(r) is obtained analytically. This, only weakly material-dependent function is found to decrease with Mn-Mn distance much slower than its Gaussian approximation derived previously. The exact form of the decay of the superexchange can be approximated by a power law J0r-8.5. This is close to an experimental result, J0r-6.8, determined on the basis of the spin-glass transition temperature on the composition.

  12. Optical devices for biochemical sensing in flame hydrolysis deposited glass

    NASA Astrophysics Data System (ADS)

    Ruano-Lopez, Jesus M.

    Previous research in the field of Flame Hydrolysis Deposition (FHD) of glasses has focused on the production of low cost optical devices for the field of telecommunications. The originality of this doctoral research resides in the exploration of this technology in the fabrication of optical bio-chemical sensors, with integrated "Lab-on-a-chip" devices. To achieve this goal, we have combined and applied different microfabrication processes for the manufacture of sensor platforms using FHD. These structures are unique in that they take advantage of the intrinsic benefits of the microfabrication process, such as, miniaturisation and mass production, and combine them with the properties of FHD glass, namely: low loss optical transducing mechanisms, planar technologies and monolithic integration. This thesis demonstrates that FHD is a suitable technology for biosensing and Lab- on-a-Chip applications. The objective is to provide future researchers with the necessary tools to accomplish an integrated analytical system based on FHD. We have designed, fabricated, and successfully tested a FHD miniaturised sensor, which comprised optical and microfluidic circuitry, in the framework of low volume fluorescence assays. For the first time, volumes as low as 570 pL were analysed with a Cyanine-5 fluorophore with a detection limit of 20 pM, or ca. 6000 molecules (+/-3sigma) for this platform. The fabrication of the sensor generated a compilation of processes that were then utilised to produce other possible optical platforms for bio-chemical sensors in FHD, e.g. arrays and microfluidics. The "catalogue" of methods used included new recipes for reactive ion etching, glass deposition and bonding techniques that enabled the development of the microfluidic circuitry, integrated with an optical circuitry. Furthermore, we developed techniques to implement new tasks such as optical signal treatment using integrated optical structures, planar arraying of sensors, a separating element for liquid chromatography, and finally a pumping system for delivering small amounts of liquid along the microfluidic channels. This thesis comprises six chapters. In Chapter 1, an overview of the topic was presented, offering a review of the various fields addressed, as well as a description of the motivation and originality of this work. Chapter 2 describes the processes developed to fabricate an optical sensor, and Chapter 3 assesses its performance. In Chapter 4, integrated optical circuit designs and their fabrication methods, as well as developing and testing of an array of sensors, are presented. The description of a separating element involved in a liquid chromatography system, and the pumping of liquids in a FHD optical device, were addressed in Chapter 5. Finally, Chapter 6 summarised the conclusions and suggested possible future work. Last but not least, the appendix, contains techniques for hybrid integration; recipes for etching of rare earth glasses; as well as instrumentation designs. This research has taken Flame Hydrolysis Deposition technique into the world of optical bio-chemical sensors, creating a bridge between analytical assays and FHD glass. In this respect, the demonstrated flexibility of the technology will enable a variety of configurations to be created and implemented, with the prospect of using the techniques for laboratory-on-a-chip technologies. The work has been patented by the University of Glasgow, for future exploitation in analytical biotechnology and Lab-on-a-Chip.

  13. Contribution of first-principles calculations to multinuclear NMR analysis of borosilicate glasses.

    PubMed

    Soleilhavoup, Anne; Delaye, Jean-Marc; Angeli, Frédéric; Caurant, Daniel; Charpentier, Thibault

    2010-12-01

    Boron-11 and silicon-29 NMR spectra of xSiO(2)-(1-x)B(2)O(3) glasses (x=0.40, 0.80 and 0.83) have been calculated using a combination of molecular dynamics (MD) simulations with density functional theory (DFT) calculations of NMR parameters. Structure models of 200 atoms have been generated using classical force fields and subsequently relaxed at the PBE-GGAlevel of DFT theory. The gauge including projector augmented wave (GIPAW) method is then employed for computing the shielding and electric field gradient tensors for each silicon and boron atom. Silicon-29 MAS and boron-11 MQMAS NMR spectra of two glasses (x=0.40 and 0.80) have been acquired and theoretical spectra are found to well agree with the experimental data. For boron-11, the NMR parameter distributions have been analysed using a Kernel density estimation (KDE) approach which is shown to highlight its main features. Accordingly, a new analytical model that incorporates the observed correlations between the NMR parameters is introduced. It significantly improves the fit of the (11)B MQMAS spectra and yields, therefore, more reliable NMR parameter distributions. A new analytical model for a quantitative description of the dependence of the silicon-29 and boron-11 isotropic chemical shift upon the bond angles is proposed, which incorporates possibly the effect of SiO(2)-B(2)O(3) intermixing. Combining all the above procedures, we show how distributions of Si-O-T and B-O-T (T=Si, B) bond angles can be estimated from the distribution of isotropic chemical shift of silicon-29 and boron-11, respectively. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Self-diffusion coefficients and shear viscosity of inverse power fluids: from hard- to soft-spheres.

    PubMed

    Heyes, D M; Brańka, A C

    2008-07-21

    Molecular dynamics computer simulation has been used to compute the self-diffusion coefficient, D, and shear viscosity, eta(s), of soft-sphere fluids, in which the particles interact through the soft-sphere or inverse power pair potential, phi(r) = epsilon(sigma/r)(n), where n measures the steepness or stiffness of the potential, and epsilon and sigma are a characteristic energy and distance, respectively. The simulations were carried out on monodisperse systems for a range of n values from the hard-sphere (n --> infinity) limit down to n = 4, and up to densities in excess of the fluid-solid co-existence value. A new analytical procedure is proposed which reproduces the transport coefficients at high densities, and can be used to extrapolate the data to densities higher than accurately accessible by simulation or experiment, and tending to the glass transition. This formula, DX(c-1) proportional, variant A/X + B, where c is an adjustable parameter, and X is either the packing fraction or the pressure, is a development of one proposed by Dymond. In the expression, -A/B is the value of X at the ideal glass transition (i.e., where D and eta(s)(-1) --> 0). Estimated values are presented for the packing fraction and the pressure at the glass transition for n values between the hard and soft particle limits. The above expression is also shown to reproduce the high density viscosity data of supercritical argon, krypton and nitrogen. Fits to the soft-sphere simulation transport coefficients close to solid-fluid co-existence are also made using the analytic form, ln(D) = alpha(X)X, and n-dependence of the alpha(X) is presented (X is either the packing fraction or the pressure).

  15. Packaged integrated opto-fluidic solution for harmful fluid analysis

    NASA Astrophysics Data System (ADS)

    Allenet, T.; Bucci, D.; Geoffray, F.; Canto, F.; Couston, L.; Jardinier, E.; Broquin, J.-E.

    2016-02-01

    Advances in nuclear fuel reprocessing have led to a surging need for novel chemical analysis tools. In this paper, we present a packaged lab-on-chip approach with co-integration of optical and micro-fluidic functions on a glass substrate as a solution. A chip was built and packaged to obtain light/fluid interaction in order for the entire device to make spectral measurements using the photo spectroscopy absorption principle. The interaction between the analyte solution and light takes place at the boundary between a waveguide and a fluid micro-channel thanks to the evanescent part of the waveguide's guided mode that propagates into the fluid. The waveguide was obtained via ion exchange on a glass wafer. The input and the output of the waveguides were pigtailed with standard single mode optical fibers. The micro-scale fluid channel was elaborated with a lithography procedure and hydrofluoric acid wet etching resulting in a 150+/-8 μm deep channel. The channel was designed with fluidic accesses, in order for the chip to be compatible with commercial fluidic interfaces/chip mounts. This allows for analyte fluid in external capillaries to be pumped into the device through micro-pipes, hence resulting in a fully packaged chip. In order to produce this co-integrated structure, two substrates were bonded. A study of direct glass wafer-to-wafer molecular bonding was carried-out to improve detector sturdiness and durability and put forward a bonding protocol with a bonding surface energy of γ>2.0 J.m-2. Detector viability was shown by obtaining optical mode measurements and detecting traces of 1.2 M neodymium (Nd) solute in 12+/-1 μL of 0.01 M and pH 2 nitric acid (HNO3) solvent by obtaining an absorption peak specific to neodymium at 795 nm.

  16. Identification of ε-Fe2O3 nano-phase in borate glasses doped with Fe and Gd

    NASA Astrophysics Data System (ADS)

    Ivanova, O. S.; Ivantsov, R. D.; Edelman, I. S.; Petrakovskaja, E. A.; Velikanov, D. A.; Zubavichus, Y. V.; Zaikovskii, V. I.; Stepanov, S. A.

    2016-03-01

    A new type of magnetic nanoparticles was revealed in borate glasses co-doped with low contents of iron and gadolinium. Structure and magnetic properties of the particles differ essentially from that of the α-Fe2O3, γ-Fe2O3, or Fe3O4 nanoparticles which were detected earlier in similar glass matrices. Transmission electron microscopy including STEM-HAADF and EDX, synchrotron radiation-based XRD, static magnetic measurements, magnetic circular dichroism, and electron magnetic resonance studies allow referring the nanoparticles to the iron oxide phase-ε-Fe2O3. Analysis of the data set has shown that it is Gd atoms that govern the process of nanoparticles' nucleation and its incorporation into the particles in different proportions can be used to adjust their magnetic and magneto-optical characteristics.

  17. Analytic studies of the hard dumbell fluid

    NASA Astrophysics Data System (ADS)

    Morriss, G. P.; Cummings, P. T.

    A closed form analytic theory for the structure of the hard dumbell fluid is introduced and evaluated. It is found to be comparable in accuracy to the reference interaction site approximation (RISA) of Chandler and Andersen.

  18. Analytical Electrochemistry: Theory and Instrumentation of Dynamic Techniques.

    ERIC Educational Resources Information Center

    Johnson, Dennis C.

    1980-01-01

    Emphasizes trends in the development of six topics concerning analytical electrochemistry, including books and reviews (34 references cited), mass transfer (59), charge transfer (25), surface effects (33), homogeneous reactions (21), and instrumentation (31). (CS)

  19. Preparation and characterization of novel foamed porous glass-ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasmal, Nibedita; Garai, Mrinmoy; Karmakar, Basudeb, E-mail: basudebk@cgcri.res.in

    2015-05-15

    Foamed glass-ceramics without using foaming agent have been synthesized in a novel glass system of SrO-CaO-Al{sub 2}O{sub 3}-TiO{sub 2}-B{sub 2}O{sub 3}-SiO{sub 2}-P{sub 2}O{sub 5}-M{sub x}O{sub y} (where M = Ba, Mg, La, Ce and Ni) by a simple process of powder sintering. The glass and glass-ceramics are characterized by dilatometry, differential scanning calorimetry (DSC), heating stage microscopy (HSM), X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), optical microscopy and Fourier transformed infrared spectroscopy (FTIR). All the glasses formed are amorphous and the glass transition temperature and dilatometric softening temperature of these glasses are found to be in the rangemore » 673–678 °C and 706–728 °C respectively. The glasses are highly stable as indicated by the DSC evaluated glass stability parameters of the range 195–240 °C. Quantitative sintering study of glass powder compacts revealed swelling in the samples with NiO and CeO{sub 2} corresponding to a geometry change of 75 and 108% around 900 °C respectively. With reference to this finding the glass powder compacts are heated to 900 °C and the foamed glass-ceramics are obtained. Characteristic crystalline silicate phases have been identified in the XRD studies and their microstructures are recorded by FESEM. Optical microscope study of the foamed samples revealed formation of bigger foamed cavity with residual pores in samples with NiO and CeO{sub 2} in comparison to samples with BaO, MgO and La{sub 2}O{sub 3}. The mean pore diameters of the samples with NiO and CeO{sub 2} are determined to be 43 and 32 μm, and their respective porosities are 2.34 and 1.82 cm{sup 3}/g respectively. Thus NiO and CeO{sub 2} are found to be very effective to obtain foamed glass-ceramics without using foaming agent by the viscous flow sintering of fine glass powder compacts along with the reduction of the respective polyvalent ions. - Highlights: • Synthesis of foamed porous glass-ceramics without foaming agent by sintering method • Only powder compact yielded foamed porous glass-ceramics but bulk glass did not. • Glasses containing NiO and CeO{sub 2} exhibited significant foaming efficiency. • Bloating of entrapped gas during viscous flow sintering is the origin of foaming. • Residual void created pores in the sintered glass-ceramics as evidenced in FESEM.« less

  20. Comparison of δ18O measurements in nitrate by different combustion techniques

    USGS Publications Warehouse

    Revesz, Kinga; Böhlke, John Karl

    2002-01-01

    Three different KNO3 salts with δ18O values ranging from about −31 to +54‰ relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with δ18O values in the midpoint of the δ18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25‰). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the δ18O scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with δ18O values far from that of atmospheric O2, to improve interlaboratory comparability.

  1. Sensitivity Analysis of Kinetic Rate-Law Parameters Used to Simulate Long-Term Weathering of ILAW Glass. Erratum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Gary L.

    2016-09-06

    This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

  2. Research on the processing technology of elongated holes based on rotary ultrasonic drilling

    NASA Astrophysics Data System (ADS)

    Tong, Yi; Chen, Jianhua; Sun, Lipeng; Yu, Xin; Wang, Xin

    2014-08-01

    The optical glass is hard, brittle and difficult to process. Based on the method of rotating ultrasonic drilling, the study of single factor on drilling elongated holes was made in optical glass. The processing equipment was DAMA ultrasonic machine, and the machining tools were electroplated with diamond. Through the detection and analysis on the processing quality and surface roughness, the process parameters (the spindle speed, amplitude, feed rate) of rotary ultrasonic drilling were researched, and the influence of processing parameters on surface roughness was obtained, which will provide reference and basis for the actual processing.

  3. Fluorescence metrology used for analytics of high-quality optical materials

    NASA Astrophysics Data System (ADS)

    Engel, Axel; Haspel, Rainer; Rupertus, Volker

    2004-09-01

    Optical, glass ceramics and crystals are used for various specialized applications in telecommunication, biomedical, optical, and micro lithography technology. In order to qualify and control the material quality during the research and production processes several specialized ultra trace analytisis methods have to be appliedcs Schott Glas is applied. One focus of our the activities is the determination of impurities ranging in the sub ppb-regime, because such kind of impurity level is required e.g. for pure materials used for microlithography for example. Common analytical techniques for these impurity levels areSuch impurities are determined using analytical methods like LA ICP-MS and or Neutron Activation Analysis for example. On the other hand direct and non-destructive optical analysistic becomes is attractive because it visualizes the requirement of the optical applications additionally. Typical eExamples are absorption and laser resistivity measurements of optical material with optical methods like precision spectral photometers and or in-situ transmission measurements by means ofusing lamps and or UV lasers. Analytical methods have the drawback that they are time consuming and rather expensive, whereas the sensitivity for the absorption method will not be sufficient to characterize the future needs (coefficient much below 10-3 cm-1). For a non-destructive qualification for the current and future quality requirements a Jobin Yvon FLUOROLOG 3.22 fluorescence spectrometery is employed to enable fast and precise qualification and analysis. The main advantage of this setup is the combination of highest sensitivity (more than one order of magnitude higher sensitivity than state of the art UV absorption spectroscopy), fast measurement and evaluation cycles (several minutes compared to several hours necessary for chemical analystics). An overview is given for spectral characteristics using specified standards, which are necessary to establish the analytical system. The elementary fluorescence and absorption of rare earth element impurities as well as crystal defects induced luminescence originated by impurities was investigated. Quantitative numbers are given for the relative quantum yield as well as for the excitation cross section for doped glass and calcium fluoride.

  4. Properties of Desert Sand and CMAS Glass

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.; Choi, Sung R.

    2014-01-01

    As-received desert sand from a Middle East country has been characterized for its phase composition and thermal stability. X-ray diffraction analysis showed the presence of quartz (SiO2), calcite (CaCO3), gypsum (CaSO4.2H2O), and NaAlSi3O8 phases in as-received desert sand and showed weight loss of approx. 35 percent due to decomposition of CaCO3 and CaSO4.2H2O when heated to 1400 C. A batch of as-received desert sand was melted into calcium magnesium aluminosilicate (CMAS) glass at approx. 1500 C. From inductively coupled plasma-atomic emission spectrometry, chemical composition of the CMAS glass was analyzed to be 27.8CaO-4MgO-5Al2O3-61.6SiO2-0.6Fe2O3-1K2O (mole percent). Various physical, thermal and mechanical properties of the glass have been evaluated. Bulk density of CMAS glass was 2.69 g/cc, Young's modulus 92 GPa, Shear modulus 36 GPa, Poisson's ratio 0.28, dilatometric glass transition temperature (T (sub g)) 706 C, softening point (T (sub d)) 764 C, Vickers microhardness 6.3 +/- 0.4 GPa, indentation fracture toughness 0.75 +/- 0.15 MPa.m (sup 1/2), and coefficient of thermal expansion (CTE) 9.8 x 10 (exp -6)/degC in the temperature range 25 to 700 C. Temperature dependence of viscosity has also been estimated from various reference points of the CMAS glass using the Vogel-Fulcher-Tamman (VFT) equation. The glass remained amorphous after heat treating at 850 C for 10 hr but crystallized into CaSiO3 and Ca-Mg-Al silicate phases at 900 C or higher temperatures. Crystallization kinetics of the CMAS glass has also been investigated by differential thermal analysis (DTA). Activation energies for the crystallization of two different phases in the glass were calculated to be 403 and 483 kJ/mol, respectively.

  5. A reagentless enzymatic fluorescent biosensor for glucose based on upconverting glasses, as excitation source, and chemically modified glucose oxidase.

    PubMed

    Del Barrio, Melisa; Cases, Rafael; Cebolla, Vicente; Hirsch, Thomas; de Marcos, Susana; Wilhelm, Stefan; Galbán, Javier

    2016-11-01

    Upon near-infrared excitation Tm(3+)+Yb(3+) doped fluorohafnate glasses present upconversion properties and emit visible light. This property permits to use these glasses (UCG) as excitation sources for fluorescent optical biosensors. Taking this into account, in this work a fluorescent biosensor for glucose determination is designed and evaluated. The biosensor combines the UCG and the fluorescence of the enzyme glucose oxidase chemically modified with a fluorescein derivative (GOx-FS), whose intensity is modified during the enzymatic reaction with glucose. Optical parameters have been optimized and a mathematical model describing the behavior of the analytical signal is suggested. Working in FIA mode, the biosensor responds to glucose concentrations up to, at least, 15mM with a limit of detection of 1.9mM. The biosensor has a minimum lifetime of 9 days and has been applied to glucose determination in drinks. The applicability of the sensor was tested by glucose determination in two fruit juices. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    PubMed Central

    2011-01-01

    Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356

  7. Characterization of surface properties of glass vials used as primary packaging material for parenterals.

    PubMed

    Ditter, Dominique; Mahler, Hanns-Christian; Roehl, Holger; Wahl, Michael; Huwyler, Joerg; Nieto, Alejandra; Allmendinger, Andrea

    2018-04-01

    The appropriate selection of adequate primary packaging, such as the glass vial, rubber stopper, and crimp cap for parenteral products is of high importance to ensure product stability, microbiological quality (integrity) during storage as well as patient safety. A number of issues can arise when inadequate vial material is chosen, and sole compliance to hydrolytic class I is sometimes not sufficient when choosing a glass vial. Using an appropriate pre-treatment, such as surface modification or coating of the inner vial surface after the vial forming process the glass container quality is often improved and interactions of the formulation with the surface of glass may be minimized. This study aimed to characterize the inner surface of different type I glass vials (Exp33, Exp51, Siliconized, TopLyo™ and Type I plus®) at the nanoscale level. All vials were investigated topographically by colorimetric staining and Scanning Electron Microscopy (SEM). Glass composition of the surface was studied by Time-of-Flight - Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS), and hydrophobicity/hydrophilicity of the inner surface was assessed by dye tests and surface energy measurements. All containers were studied unprocessed, as received from the vendor, i.e. in unwashed and non-depyrogenized condition. Clear differences were found between the different vial types studied. Especially glass vials without further surface modifications, like Exp33 and Exp51 vials, showed significant (I) vial-to-vial variations within one vial lot as well as (II) variations along the vertical axis of a single vial when studying topography and chemical composition. In addition, differences and heterogeneity in surface energy were found within a given tranche (circumferential direction) of Exp51 as well as Type I plus® vials. Most consistent quality was achieved with TopLyo™ vials. The present comprehensive characterization of surface properties of the different vial types may serve as basis to further guide the selection of adequate primary packaging based on the desired quality target product profile and to support studies of glass surface interactions with formulations. The proposed analytical method panel can be used for characterization of future glass vials either before delivery to the manufacturer or drug product manufacturing. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Phase equilibrium and preparation, crystallization and viscous sintering of glass in the alumina-silica-lanthanum phosphate system

    NASA Astrophysics Data System (ADS)

    He, Feng

    The phase equilibrium, viscosity of melt-quenched glasses, and processing of sol-gel glasses of the alumina-silica-lanthanum phosphate system were studied. These investigations were directed towards serving the objective of synthesizing nano-structured ceramic-matrix-composites via controlled crystallization of glass precursors. The thermal stability, phase equilibrium, and liquidus temperatures of the alumina- and mullite-lanthanum phosphate systems are determined. An iridium wire heater was constructed to anneal samples up to 2200°C. Phosphorus evaporation losses were significant at high temperatures, especially over 1800°C. The tentative phase diagrams of the two quasi-binary systems were presented. The viscosity of the melt-quenched mullite-lanthanum phosphate glasses was measured by three different methods, including viscous sintering of glass powder compacts, neck formation between two Frenkel glass beads, and thermal analysis of the glass transition. Improved methodologies were developed for applying the interpretative mathematical models to the results of the sintered powder and thermal analytical experiments. Good agreement was found between all three methods for both absolute values and temperature dependence. A sol-gel process was developed as a low temperature route to producing glasses. A unique, single phase mullite gel capable of low temperature (575°C) mullitization was made from tetraethoxysilane and aluminum isopropoxide at room temperature in three days. Low temperature crystallization was attributed to the avoidance of phase segregation during gel formation and annealing. This was greatly enhanced by a combination of low temperature preheating in the amorphous state, a high heating rate during crystallization and low water content. The Al2O3 content in mullite (61-68 mol%) depended on the highest annealing temperature. Two mullite-lanthanum phosphate gels were made based upon modifying the chemical procedures used for the homogeneous single phase and heterogeneous diphasic mullite gels from same starting chemicals. Amorphous powders were obtained after optimized calcinations. Their different crystallization routes and sintering behavior were investigated and correlated with the different homogeneities of precursor gels. Structurally stable open, porous ceramics (up to 80% porosity) were produced from the single-phase gel derived powder, where gases exsolved during calcination caused foaming coincident with sintering. Translucent, dense glass ceramic was made from the calcined diphasic gel by hot-pressing.

  9. Learning Analytics: Insights into the Natural Learning Behavior of Our Students

    ERIC Educational Resources Information Center

    Becker, Bernd

    2013-01-01

    The migration from traditional classrooms to online learning environments is in full effect. In the midst of these changes, a new approach to learning analytics needs to be considered. Learning analytics refers to the process of collecting and studying usage data in order to make instructional decisions that will support student success. In…

  10. Development and Validation of a Learning Analytics Framework: Two Case Studies Using Support Vector Machines

    ERIC Educational Resources Information Center

    Ifenthaler, Dirk; Widanapathirana, Chathuranga

    2014-01-01

    Interest in collecting and mining large sets of educational data on student background and performance to conduct research on learning and instruction has developed as an area generally referred to as learning analytics. Higher education leaders are recognizing the value of learning analytics for improving not only learning and teaching but also…

  11. MIT CSAIL and Lincoln Laboratory Task Force Report

    DTIC Science & Technology

    2016-08-01

    projects have been very diverse, spanning several areas of CSAIL concentration, including robotics, big data analytics , wireless communications...spanning several areas of CSAIL concentration, including robotics, big data analytics , wireless communications, computing architectures and...to machine learning systems and algorithms, such as recommender systems, and “Big Data ” analytics . Advanced computing architectures broadly refer to

  12. The relationship between schizotypal facets and conspiracist beliefs via cognitive processes.

    PubMed

    Barron, David; Furnham, Adrian; Weis, Laura; Morgan, Kevin D; Towell, Tony; Swami, Viren

    2018-01-01

    This study sought to replicate previous work showing relationships between components of schizotypy and conspiracist beliefs, and extend it by examining the mediating role of cognitive processes. An international online sample of 411 women and men (mean age = 35.41 years) completed measures of the schizotypal facets of Odd Beliefs or Magical Thinking and Ideas of Reference, conspiracist beliefs, and cognitive processes related to need for cognition, analytic thinking, and cognitive insight. Path analysis confirmed the associations between both schizotypal facets and conspiracist beliefs in the present sample. Confirmatory evidence was found for the association between analytic thinking and conspiracist beliefs, and results also suggested an association between cognitive insight and conspiracist beliefs. Cognitive insight also mediated the link between Odd Beliefs or Magical Thinking and Ideas of Reference with conspiracist beliefs. However, analytic thinking provided a mediating link to conspiracy ideation for Odd Beliefs or Magical Thinking and not Ideas of Reference. Finally, there was an association between Odd Beliefs or Magical Thinking and need for cognition, but this path did not extend to conspiracist beliefs. These results suggest possible mediating roles for analytic thinking and self-certainty between schizotypy and conspiracist beliefs. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Using Streaming Analytics for Effective Real Time Network Visibility -

    Science.gov Websites

    problem before it became a big issue. That's just one use case as to how you can make use of this sort of , having the ability to see all of your network traffic in one place, single pane of glass, will allow you , malware detection devices, other networks' ability tools. I was never able to see everything in one spot

  14. Vapor-Phase Infrared Absorptivity Coefficient of HN1

    DTIC Science & Technology

    2013-08-01

    the boil-off of a bulk liquid nitrogen tank, across an alumina Soxhlet thimble in a glass holder filled with the analyte. A vapor–liquid...with mass spectrometry (MS) yielded the results shown in Table 3. Table 3. Results from Analysis of HN1 Sample Used for Determination of...2 yields (3) Equation 3 can then be solved at each frequency using a least-squares approach. This was

  15. Compression-recovery model of absorptive glass mat (AGM) separator guided by X-ray micro-computed tomography analysis

    NASA Astrophysics Data System (ADS)

    Kameswara Rao, P. V.; Rawal, Amit; Kumar, Vijay; Rajput, Krishn Gopal

    2017-10-01

    Absorptive glass mat (AGM) separators play a key role in enhancing the cycle life of the valve regulated lead acid (VRLA) batteries by maintaining the elastic characteristics under a defined level of compression force with the plates of the electrodes. Inevitably, there are inherent challenges to maintain the required level of compression characteristics of AGM separators during the charge and discharge of the battery. Herein, we report a three-dimensional (3D) analytical model for predicting the compression-recovery behavior of AGM separators by formulating a direct relationship with the constituent fiber and structural parameters. The analytical model of compression-recovery behavior of AGM separators has successfully included the fiber slippage criterion and internal friction losses. The presented work uses, for the first time, 3D data of fiber orientation from X-ray micro-computed tomography, for predicting the compression-recovery behavior of AGM separators. A comparison has been made between the theoretical and experimental results of compression-recovery behavior of AGM samples with defined fiber orientation characteristics. In general, the theory agreed reasonably well with the experimental results of AGM samples in both dry and wet states. Through theoretical modeling, fiber volume fraction was established as one of the key structural parameters that modulates the compression hysteresis of an AGM separator.

  16. Deconstructing three-dimensional (3D) structure of absorptive glass mat (AGM) separator to tailor pore dimensions and amplify electrolyte uptake

    NASA Astrophysics Data System (ADS)

    Rawal, Amit; Rao, P. V. Kameswara; Kumar, Vijay

    2018-04-01

    Absorptive glass mat (AGM) separator is a vital technical component in valve regulated lead acid (VRLA) batteries that can be tailored for a desired application. To selectively design and tailor the AGM separator, the intricate three-dimensional (3D) structure needs to be unraveled. Herein, a toolkit of 3D analytical models of pore size distribution and electrolyte uptake expressed via wicking characteristics of AGM separators under unconfined and confined states is presented. 3D data of fiber orientation distributions obtained previously through X-ray micro-computed tomography (microCT) analysis are used as key set of input parameters. The predictive ability of pore size distribution model is assessed through the commonly used experimental set-up that usually apply high level of compressive stresses. Further, the existing analytical model of wicking characteristics of AGM separators has been extended to account for 3D characteristics, and subsequently, compared with the experimental results. A good agreement between the theory and experiments pave the way to simulate the realistic charge-discharge modes of the battery by applying cyclic loading condition. A threshold criterion describing the invariant behavior of pore size and wicking characteristics in terms of maximum permissible limit of key structural parameters during charge-discharge mode of the battery has also been proposed.

  17. On-matrix Derivatization for Dynamic Headspace Sampling of Nonvolatile Surface Residues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, Scott D.; Wahl, Jon H.

    2012-09-01

    The goal of this study is to extend sampling by the field and laboratory emission cell (FLEC) purge-and-trap technique to applications that target nonvolatile residues. On-matrix derivatization of residues to render analytes stable and more volatile is explored to achieve this goal. Results show that on-matrix derivatizations of nerve agent hydrolysis products (monoalkyl methylphosphonic acids and methylphosphonic acid [MPA]) with diazomethane were successful on glass and painted wallboard (at the 10-µg level). It also was successful on the more difficult concrete (at the 500-µg level) and carpet (at the 20-µg level) substrates that cannot be successfully sampled using swipe techniques.more » Analysis of additional chemical warfare (CW)-associated residues can be approached by on-matrix derivatization with trifluoroacetic anhydride (TFAA). For example, amines (used as stabilizers or present as decomposition products of the nerve agent VX) or thiodiglycol (hydrolysis product of sulfur mustard) could be sampled as their TFAA derivatives from glass, painted wallboard, and concrete (at the 40-µg level), as well as carpet (at the 80-µg level) surfaces. Although the amine and thiodiglycol are semi-volatile and could be sampled directly, derivatization improves the recovery and chromatographic behavior of these analytes.« less

  18. On-matrix derivatization for dynamic headspace sampling of nonvolatile surface residues.

    PubMed

    Harvey, Scott D; Wahl, Jon H

    2012-09-21

    The goal of this study is to extend sampling by the field and laboratory emission cell (FLEC) dynamic headspace technique to applications that target nonvolatile residues. On-matrix derivatization of residues to render analytes stable and more volatile is explored to achieve this goal. Results show that on-matrix derivatizations of nerve agent hydrolysis products (monoalkyl methylphosphonic acids and methylphosphonic acid [MPA]) with diazomethane were successful on glass and painted wallboard (at the 10-μg level). It also was successful on the more difficult concrete (at the 500-μg level) and carpet (at the 20-μg level), substrates that cannot be successfully sampled using swipe techniques. Analysis of additional chemical warfare (CW)-associated residues can be approached by on-matrix derivatization with trifluoroacetic anhydride (TFAA). For example, amines (used as stabilizers or present as decomposition products of the nerve agent VX) or thiodiglycol (hydrolysis product of sulfur mustard) could be sampled as their TFAA derivatives from glass, painted wallboard, and concrete (at the 40-μg level), as well as carpet (at the 80-μg level) surfaces. Although the amine and thiodiglycol are semi-volatile and could be sampled directly, derivatization improves the recovery and chromatographic behavior of these analytes. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Polyethylenimine-assisted seed-mediated synthesis of gold nanoparticles for surface-enhanced Raman scattering studies

    NASA Astrophysics Data System (ADS)

    Philip, Anish; Ankudze, Bright; Pakkanen, Tuula T.

    2018-06-01

    Large-sized gold nanoparticles (AuNPs) were synthesized with a new polyethylenimine - assisted seed - mediated method for surface-enhanced Raman scattering (SERS) studies. The size and polydispersity of gold nanoparticles are controlled in the growth step with the amounts of polyethylenimine (PEI) and seeds. Influence of three silicon oxide supports having different surface morphologies, namely halloysite (Hal) nanotubes, glass plates and inverse opal films of SiO2, on the performance of gold nanoparticles in Raman scattering of a 4-aminothiophenol (4-ATP) analyte was investigated. Electrostatic interaction between positively charged polyethylenimine-capped AuNPs and negatively charged surfaces of silicon oxide supports was utilized in fabrication of the SERS substrates using deposition and infiltration methods. The Au-photonic crystal of the three SERS substrate groups is the most active one as it showed the highest analytical enhancement factor (AEF) and the lowest detection limit of 1x10-8 M for 4-ATP. Coupling of the optical properties of photonic crystals with the plasmonic properties of AuNPs provided Au-photonic crystals with the high SERS activity. The AuNPs clusters formed both in the photonic crystal and on the glass plate are capable of forming more hot spots as compared to sparsely distributed AuNPs on Hal nanotubes and thereby increasing the SERS enhancement.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byerly, Benjamin L.; Stanley, Floyd; Spencer, Khal

    In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.

  1. ENVIRONMENTAL IMMUNOCHEMISTRY RESPONDING TO A SPECTRUM OF ANALYTICAL NEEDS

    EPA Science Inventory

    A review, with 13 references, is given on the field of environmental immunochemistry which brings together several specalties, including analytical chemistry, biochemistry, moluclar biology, and environmental engineering. This multidisciplinary nature is both benefit and a confus...

  2. Analytical Electrochemistry: Methodology and Applications of Dynamic Techniques.

    ERIC Educational Resources Information Center

    Heineman, William R.; Kissinger, Peter T.

    1980-01-01

    Reports developments involving the experimental aspects of finite and current analytical electrochemistry including electrode materials (97 cited references), hydrodynamic techniques (56), spectroelectrochemistry (62), stripping voltammetry (70), voltammetric techniques (27), polarographic techniques (59), and miscellany (12). (CS)

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raszewski, F; Tommy Edwards, T; David Peeler, D

    Sludge Batch 4 (SB4) is currently being processed in the Defense Waste Processing Facility (DWPF) using Frit 510. The slurry pumps in Tank 40 are experiencing in-leakage of bearing water, which is causing the sludge slurry feed in Tank 40 to become dilute at a rapid rate. Currently, the DWPF is removing this dilution water by performing caustic boiling during the Sludge Receipt and Adjustment Tank (SRAT) cycle. In order to alleviate prolonged SRAT cycle times that may eventually impact canister production rates, decant scenarios of 100, 150, and 200 kilogallons of supernate were proposed for Tank 40 during themore » DWPF March outage. Based on the results of the preliminary assessment issued by the Savannah River National Laboratory (SRNL), the Liquid Waste Organization (LWO) issued a Technical Task Request (TTR) for SRNL to (1) perform a more detailed evaluation using updated SB4 compositional information and (2) assess the viability of Frit 510 and determine any potential impacts on the SB4 system. As defined in the TTR, LWO requested that SRNL validate the sludge--only SB4 flowsheet and the coupled operations flowsheet using the 100K gallon decant volume as well as the addition of 3 wt% sodium on a calcined oxide basis. Approximately 12 historical glasses were identified during a search of the ComProTM database that are located within at least one of the five glass regions defined by the proposed SB4 flowsheet options. While these glasses meet the requirements of a variability study there was some concern that the compositional coverage did not adequately bound all cases. Therefore, SRNL recommended that a supplemental experimental variability study be performed to support the various SB4 flowsheet options that may be implemented for future SB4 operations in DWPF. Eighteen glasses were selected based on nominal sludge projections representing the current as well as the proposed flowsheets over a WL interval of interest to DWPF (32-42%). The intent of the experimental portion of the variability study is to demonstrate that the glasses of the Frit 510-modified SB4 compositional region (Cases No.1-5) are both acceptable relative to the Environmental Assessment (EA) reference glass and predictable by the current DWPF process control models for durability. Frit 510 is a viable option for the processing of SB4 after a Tank 40 decant and the addition of products from the Actinide Removal Process (ARP). The addition of ARP did not have any negative impacts on the acceptability and predictability of the variability study glasses. The results of the variability study indicate that all of the study glasses (both quenched and centerline canister cooled (ccc)) have normalized releases for boron that are well below the reference EA glass (16.695 g/L). The durabilities of all of the study glasses are predictable using the current Product Composition Control System (PCCS) durability models with the exception of SB4VAR24ccc (Case No.2 at 41%). PCCS is not applicable to non-homogeneous glasses (i.e. glasses containing crystals such as acmite and nepheline), thus SB4VAR24ccc should not be predictable as it contains nepheline. The presence of nepheline has been confirmed in both SB4VAR13ccc and SB4VAR24ccc by X-ray diffraction (XRD). These two glasses are the first results which indicate that the current nepheline discriminator value of 0.62 is not conservative. The nepheline discriminator was implemented into PCCS for SB4 based on the fact that all of the historical glasses evaluated with nepheline values of 0.62 or greater did not contain nepheline via XRD analysis. Although these two glasses do cause some concern over the use of the 0.62 nepheline value for future DWPF glass systems, the impact to the current SB4 system is of little concern. More specifically, the formation of nepheline was observed in glasses targeting 41 or 42% WL. Current processing of the Frit 510-SB4 system in DWPF has nominally targeted 34% WL. For the SB4 variability study glasses targeting these lower WLs, nepheline formation was not observed and the minimal difference in PCT response between quenched and ccc versions supported its absence.« less

  4. A global multicenter study on reference values: 2. Exploration of sources of variation across the countries.

    PubMed

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Shimizu, Yoshihisa; Xia, Liangyu; Hoffmann, Mariza; Shah, Swarup; Matsha, Tandi; Wassung, Janette; Smit, Francois; Ruzhanskaya, Anna; Straseski, Joely; Bustos, Daniel N; Kimura, Shogo; Takahashi, Aki

    2017-04-01

    The intent of this study, based on a global multicenter study of reference values (RVs) for serum analytes was to explore biological sources of variation (SVs) of the RVs among 12 countries around the world. As described in the first part of this paper, RVs of 50 major serum analytes from 13,396 healthy individuals living in 12 countries were obtained. Analyzed in this study were 23 clinical chemistry analytes and 8 analytes measured by immunoturbidimetry. Multiple regression analysis was performed for each gender, country by country, analyte by analyte, by setting four major SVs (age, BMI, and levels of drinking and smoking) as a fixed set of explanatory variables. For analytes with skewed distributions, log-transformation was applied. The association of each source of variation with RVs was expressed as the partial correlation coefficient (r p ). Obvious gender and age-related changes in the RVs were observed in many analytes, almost consistently between countries. Compilation of age-related variations of RVs after adjusting for between-country differences revealed peculiar patterns specific to each analyte. Judged fromthe r p , BMI related changes were observed for many nutritional and inflammatory markers in almost all countries. However, the slope of linear regression of BMI vs. RV differed greatly among countries for some analytes. Alcohol and smoking-related changes were observed less conspicuously in a limited number of analytes. The features of sex, age, alcohol, and smoking-related changes in RVs of the analytes were largely comparable worldwide. The finding of differences in BMI-related changes among countries in some analytes is quite relevant to understanding ethnic differences in susceptibility to nutritionally related diseases. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Development of a High Ionization Efficiency Molten Glass Ion Emitter for TIMS

    NASA Astrophysics Data System (ADS)

    Cheversia, M. B.; Farmer, G.; Koval, C.; David, D.

    2006-12-01

    Thermal ionization mass spectrometry (TIMS) remains the method of choice for many high precision isotope ratio determinations but is handicapped by the use of low efficiency ion emitters. For example, ionization efficiencies from molten glass emitters (Si-gel) used for such elements as Pb, Cr, Ru, and Ag are in the range of 0.05-2%, which limits the sample size and the precision to which isotope ratio determinations for these elements can be made. Our aim is to improve the ionization efficiency of the molten glass ion emitter using electrochemical methods. This work builds on recent observations indicating that many metals doped in borosilicate glasses (eg. Bi, Ag), are emitted from the liquid glass (in vacuo) primarily as the neutral metal atom. Our goal is to increase the proportion of singly charged metal atoms in metal-doped molten glasses via oxidation induced by electrochemical methods and to assess whether such in situ oxidation of metal atoms leads to an increase in emitted metal ions. Our experiments are performed in a vacuum chamber that mimics conditions in the sample chamber of the TIMS. A borosilicate glass sample is placed in a miniature ceramic crucible. The crucible contains working and reference Pt electrodes, and a Pt thermocouple. The entire apparatus is wrapped with a resistively heated Ta wire until temperatures in the glass reach approximately 1400°C, to ensure that the glass is molten. By this method, we have produced simple cyclic voltammograms that suggest that over a 100°C temperature range, the borosilicate glass undergoes a transition from resistive behavior as a solid, to a conductive electrolyte, as a molten liquid glass, as expected. The change is evident as an order of magnitude decrease in resistivity of the glass, as interpreted from the voltammograms. The voltammograms produced for the pure borosilicate glasses represent the baseline against which we will compare the electrochemical characteristics of Pb doped glasses. These experiments are currently underway and are designed to determine the speciation of lead in the glass, and to determine the voltages required to induce cathodic currents in the glass corresponding to ionization to Pb+ and Pb2+. By generating a cathodic current and an increased concentration of the oxidized species, we hope to ultimately generate a higher intensity ion beam, higher ionization efficiency for low efficiency elements, and higher precision analyses on small sample sizes for the TIMS.

  6. Quality-assurance results for routine water analysis in US Geological Survey laboratories, water year 1991

    USGS Publications Warehouse

    Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.

    1994-01-01

    The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and phosphorus. A negative or positive bias condition was indicated in three of five nutrient constituents. There was acceptable precision and no indication of bias for the 14 low ionic-strength analytical procedures tested in the National Water Quality Laboratory program and for the 32 inorganic and 5 nutrient analytical procedures tested in the Quality of Water Service Unit during water year 1991.

  7. Infrared photothermal imaging of trace explosives on relevant substrates

    NASA Astrophysics Data System (ADS)

    Kendziora, Christopher A.; Furstenberg, Robert; Papantonakis, Michael; Nguyen, Viet; Borchert, James; Byers, Jeff; McGill, R. Andrew

    2013-06-01

    We are developing a technique for the stand-off detection of trace explosives on relevant substrate surfaces using photo-thermal infrared (IR) imaging spectroscopy (PT-IRIS). This approach leverages one or more compact IR quantum cascade lasers, tuned to strong absorption bands in the analytes and directed to illuminate an area on a surface of interest. An IR focal plane array is used to image the surface and detect small increases in thermal emission upon laser illumination. The PT-IRIS signal is processed as a hyperspectral image cube comprised of spatial, spectral and temporal dimensions as vectors within a detection algorithm. The ability to detect trace analytes on relevant substrates is critical for stand-off applications, but is complicated by the optical and thermal analyte/substrate interactions. This manuscript describes recent PT-IRIS experimental results and analysis for traces of RDX, TNT, ammonium nitrate (AN) and sucrose on relevant substrates (steel, polyethylene, glass and painted steel panels). We demonstrate that these analytes can be detected on these substrates at relevant surface mass loadings (10 μg/cm2 to 100 μg/cm2) even at the single pixel level.

  8. Elemental and Isotopic Analysis of Uranium Oxide an NIST Glass Standards by FEMTOSECOND-LA-ICP-MIC-MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebert, Chris; Zamzow, Daniel S.; McBay, Eddie H.

    2009-06-01

    The objective of this work was to test and demonstrate the analytical figures of merit of a femtosecond-laser ablation (fs-LA) system coupled with an inductively coupled plasma-multi-ion collector-mass spectrometer (ICP-MIC-MS). The mobile fs-LA sampling system was designed and assembled at Ames Laboratory and shipped to Oak Ridge National Laboratory (ORNL), where it was integrated with an ICP-MIC-MS. The test period of the integrated systems was February 2-6, 2009. Spatially-resolved analysis of particulate samples is accomplished by 100-shot laser ablation using a fs-pulsewidth laser and monitoring selected isotopes in the resulting ICP-MS transient signal. The capability of performing high sensitivity, spatiallymore » resolved, isotopic analyses with high accuracy and precision and with virtually no sample preparation makes fs-LA-ICP-MIC-MS valuable for the measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. Femtosecond-LA has been shown to generate particles from the sample that are more representative of the bulk composition, thereby minimizing weaknesses encountered in previous work using nanosecond-LA (ns-LA). The improvement of fs- over ns-LA sampling arises from the different mechanisms for transfer of energy into the sample in these two laser pulse-length regimes. The shorter duration fs-LA pulses induce less heating and cause less damage to the sample than the longer ns pulses. This results in better stoichiometric sampling (i.e., a closer correlation between the composition of the ablated particles and that of the original solid sample), which improves accuracy for both intra- and inter-elemental analysis. The primary samples analyzed in this work are (a) solid uranium oxide powdered samples having different {sup 235}U to {sup 238}U concentration ratios, and (b) glass reference materials (NIST 610, 612, 614, and 616). Solid uranium oxide samples containing {sup 235}U in depleted, natural, and enriched abundances were analyzed as particle aggregates immobilized in a collodion substrate. The uranium oxide samples were nuclear reference materials (CRMs U0002, U005-A, 129-A, U015, U030-A, and U050) obtained from New Brunswick Laboratory-USDOE.« less

  9. Flexible fiber-reinforced composites with improved interfacial adhesion by mussel-inspired polydopamine and poly(methyl methacrylate) coating.

    PubMed

    Yi, Mi; Sun, Hongyang; Zhang, Hongcheng; Deng, Xuliang; Cai, Qing; Yang, Xiaoping

    2016-01-01

    To obtain a kind of light-curable fiber-reinforced composite for dental restoration, an excellent interfacial adhesion between the fiber and the acrylate resin matrix is quite essential. Herein, surface modification on glass fibers were carried out by coating them with poly(methyl methacrylate) (PMMA), polydopamine (PDA), or both. The PMMA or PDA coating was performed by soaking fibers in PMMA/acetone solution or dopamine aqueous solution. PDA/PMMA co-coated glass fibers were obtained by further soaking PDA-coated fibers in PMMA/acetone solution. These modified fibers were impregnated with bisphenol A glycidyl methacrylate (Bis-GMA)/triethylene glycol dimethacrylate (TEGDMA) (5:5, w/w) dental resin at a volume fraction of 75%, using unmodified fibers as reference. Light-cured specimens were submitted to evaluations including flexural properties, morphological observation, dynamic mechanical thermal analysis (DMTA) and pull-out test. In comparison with unmodified glass fibers, all the modified glass fibers showed enhancements in flexural strength and modulus of Bis-GMA/TEGDMA resin composites. Results of DMTA and pull-out tests confirmed that surface modification had significantly improved the interfacial adhesion between the glass fiber and the resin matrix. Particularly, the PDA/PMMA co-coated glass fibers displayed the most efficient reinforcement and the strongest interfacial adhesion due to the synergetic effects of PDA and PMMA. It indicated that co-coating method was a promising approach in modifying the interfacial compatibility between inorganic glass fiber and organic resin matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Distribution-centric 3-parameter thermodynamic models of partition gas chromatography.

    PubMed

    Blumberg, Leonid M

    2017-03-31

    If both parameters (the entropy, ΔS, and the enthalpy, ΔH) of the classic van't Hoff model of dependence of distribution coefficients (K) of analytes on temperature (T) are treated as the temperature-independent constants then the accuracy of the model is known to be insufficient for the needed accuracy of retention time prediction. A more accurate 3-parameter Clarke-Glew model offers a way to treat ΔS and ΔH as functions, ΔS(T) and ΔH(T), of T. A known T-centric construction of these functions is based on relating them to the reference values (ΔS ref and ΔH ref ) corresponding to a predetermined reference temperature (T ref ). Choosing a single T ref for all analytes in a complex sample or in a large database might lead to practically irrelevant values of ΔS ref and ΔH ref for those analytes that have too small or too large retention factors at T ref . Breaking all analytes in several subsets each with its own T ref leads to discontinuities in the analyte parameters. These problems are avoided in the K-centric modeling where ΔS(T) and ΔS(T) and other analyte parameters are described in relation to their values corresponding to a predetermined reference distribution coefficient (K Ref ) - the same for all analytes. In this report, the mathematics of the K-centric modeling are described and the properties of several types of K-centric parameters are discussed. It has been shown that the earlier introduced characteristic parameters of the analyte-column interaction (the characteristic temperature, T char , and the characteristic thermal constant, θ char ) are a special chromatographically convenient case of the K-centric parameters. Transformations of T-centric parameters into K-centric ones and vice-versa as well as the transformations of one set of K-centric parameters into another set and vice-versa are described. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.

    PubMed

    Higgins, Victoria; Chan, Man Khun; Nieuwesteeg, Michelle; Hoffman, Barry R; Bromberg, Irvin L; Gornall, Doug; Randell, Edward; Adeli, Khosrow

    2016-01-01

    The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has recently established pediatric age- and sex-specific reference intervals for over 85 biochemical markers on the Abbott Architect system. Previously, CALIPER reference intervals for several biochemical markers were successfully transferred from Abbott assays to Roche, Beckman, Ortho, and Siemens assays. This study further broadens the CALIPER database by performing transference and verification for 52 biochemical assays on the Roche cobas 6000 and the Roche Modular P. Using CLSI C28-A3 and EP9-A2 guidelines, transference of the CALIPER reference intervals was attempted for 16 assays on the Roche cobas 6000 and 36 on the Modular P. Calculated reference intervals were further verified using 100 healthy CALIPER samples. Most assays showed strong correlation between assay systems and were transferable from Abbott to the Roche cobas 6000 (81%) and the Modular P (86%). Bicarbonate and magnesium were not transferable on either system and calcium and prealbumin were not transferable to the Modular P. Of the transferable analytes, 62% and 61% were verified on the cobas 6000 and the Modular P, respectively. This study extends the utility of the CALIPER database to two additional analytical systems, which facilitates the broad application of CALIPER reference intervals at pediatric centers utilizing Roche biochemical assays. Transference studies across different analytical platforms can later be collectively analyzed in an attempt to develop common reference intervals across all clinical chemistry instruments to harmonize laboratory test interpretation in diagnosis and monitoring of pediatric disease. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Chemical micro-sensor

    DOEpatents

    Ruggiero, Anthony J.

    2005-05-03

    An integrated optical capillary electrophoresis system for analyzing an analyte. A modulated optical pump beam impinges on an capillary containing the analyte/buffer solution which is separated by electrophoresis. The thermally-induced change in the index of refraction of light in said electrophoresis capillary is monitored using an integrated micro-interferometer. The interferometer includes a first interferometer arm intersecting the electrophoresis capillary proximate the excitation beam and a second, reference interferometer arm. Changes in index of refraction in the analyte measured by interrogating the interferometer state using white light interferometry and a phase-generated carrier demodulation technique. Background thermo-optical activity in the buffer solution is cancelled by splitting the pump beam and exciting pure buffer solution in a second section of capillary where it crosses the reference arm of the interferometer.

  13. Quantitative 1H NMR: Development and Potential of an Analytical Method – an Update

    PubMed Central

    Pauli, Guido F.; Gödecke, Tanja; Jaki, Birgit U.; Lankin, David C.

    2012-01-01

    Covering the literature from mid-2004 until the end of 2011, this review continues a previous literature overview on quantitative 1H NMR (qHNMR) methodology and its applications in the analysis of natural products (NPs). Among the foremost advantages of qHNMR is its accurate function with external calibration, the lack of any requirement for identical reference materials, a high precision and accuracy when properly validated, and an ability to quantitate multiple analytes simultaneously. As a result of the inclusion of over 170 new references, this updated review summarizes a wealth of detailed experiential evidence and newly developed methodology that supports qHNMR as a valuable and unbiased analytical tool for natural product and other areas of research. PMID:22482996

  14. The Evolution of Big Data and Learning Analytics in American Higher Education

    ERIC Educational Resources Information Center

    Picciano, Anthony G.

    2012-01-01

    Data-driven decision making, popularized in the 1980s and 1990s, is evolving into a vastly more sophisticated concept known as big data that relies on software approaches generally referred to as analytics. Big data and analytics for instructional applications are in their infancy and will take a few years to mature, although their presence is…

  15. Recognizing and Reducing Analytical Errors and Sources of Variation in Clinical Pathology Data in Safety Assessment Studies.

    PubMed

    Schultze, A E; Irizarry, A R

    2017-02-01

    Veterinary clinical pathologists are well positioned via education and training to assist in investigations of unexpected results or increased variation in clinical pathology data. Errors in testing and unexpected variability in clinical pathology data are sometimes referred to as "laboratory errors." These alterations may occur in the preanalytical, analytical, or postanalytical phases of studies. Most of the errors or variability in clinical pathology data occur in the preanalytical or postanalytical phases. True analytical errors occur within the laboratory and are usually the result of operator or instrument error. Analytical errors are often ≤10% of all errors in diagnostic testing, and the frequency of these types of errors has decreased in the last decade. Analytical errors and increased data variability may result from instrument malfunctions, inability to follow proper procedures, undetected failures in quality control, sample misidentification, and/or test interference. This article (1) illustrates several different types of analytical errors and situations within laboratories that may result in increased variability in data, (2) provides recommendations regarding prevention of testing errors and techniques to control variation, and (3) provides a list of references that describe and advise how to deal with increased data variability.

  16. Silica nanoparticles on front glass for efficiency enhancement in superstrate-type amorphous silicon solar cells

    NASA Astrophysics Data System (ADS)

    Das, Sonali; Banerjee, Chandan; Kundu, Avra; Dey, Prasenjit; Saha, Hiranmay; Datta, Swapan K.

    2013-10-01

    Antireflective coating on front glass of superstrate-type single junction amorphous silicon solar cells (SCs) has been applied using highly monodispersed and stable silica nanoparticles (NPs). The silica NPs having 300 nm diameter were synthesized by Stober technique where the size of the NPs was controlled by varying the alcohol medium. The synthesized silica NPs were analysed by dynamic light scattering technique and Fourier transform infrared spectroscopy. The NPs were spin coated on glass side of fluorinated tin oxide (SnO2: F) coated glass superstrate and optimization of the concentration of the colloidal solution, spin speed and number of coated layers was done to achieve minimum reflection characteristics. An estimation of the distribution of the NPs for different optimization parameters has been done using field-emission scanning electron microscopy. Subsequently, the transparent conducting oxide coated glass with the layer having the minimum reflectance is used for fabrication of amorphous silicon SC. Electrical analysis of the fabricated cell indicates an improvement of 6.5% in short-circuit current density from a reference of 12.40 mA cm-2 while the open circuit voltage and the fill factor remains unaltered. A realistic optical model has also been proposed to gain an insight into the system.

  17. Mesoporous bioactive glasses: structure characteristics, drug/growth factor delivery and bone regeneration application

    PubMed Central

    Wu, Chengtie; Chang, Jiang

    2012-01-01

    The impact of bone diseases and trauma in the whole world has increased significantly in the past decades. Bioactive glasses are regarded as an important bone regeneration material owing to their generally excellent osteoconductivity and osteostimulativity. A new class of bioactive glass, referred to as mesoporous bioglass (MBG), was developed 7 years ago, which possess a highly ordered mesoporous channel structure and a highly specific surface area. The study of MBG for drug/growth factor delivery and bone tissue engineering has grown significantly in the past several years. In this article, we review the recent advances of MBG materials, including the preparation of different forms of MBG, composition–structure relationship, efficient drug/growth factor delivery and bone tissue engineering application. By summarizing our recent research, the interaction of MBG scaffolds with bone-forming cells, the effect of drug/growth factor delivery on proliferation and differentiation of tissue cells and the in vivo osteogenesis of MBG scaffolds are highlighted. The advantages and limitations of MBG for drug delivery and bone tissue engineering have been compared with microsize bioactive glasses and nanosize bioactive glasses. The future perspective of MBG is discussed for bone regeneration application by combining drug delivery with bone tissue engineering and investigating the in vivo osteogenesis mechanism in large animal models. PMID:23741607

  18. Commutability of food microbiology proficiency testing samples.

    PubMed

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013 The Society for Applied Microbiology.

  19. [The water content reference material of water saturated octanol].

    PubMed

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  20. Residual stress in glass: indentation crack and fractography approaches.

    PubMed

    Anunmana, Chuchai; Anusavice, Kenneth J; Mecholsky, John J

    2009-11-01

    To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Soda-lime-silica glass bar specimens (4 mm x 2.3 mm x 28 mm) were prepared and annealed at 650 degrees C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24h were statistically significant (p=0.003). This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime-silica glass. The indentation method may be useful for estimating residual stress in glass.

  1. Residual stress in glass: indentation crack and fractography approaches

    PubMed Central

    Anunmana, Chuchai; Anusavice, Kenneth J.; Mecholsky, John J.

    2009-01-01

    Objective To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Methods Soda-lime-silica glass bar specimens (4 mm × 2.3 mm × 28 mm) were prepared and annealed at 650 °C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6 N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24 h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. Results The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24 h were statistically significant (p=0.003). Significance This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime silica glass. The indentation method may be useful for estimating residual stress in glass. PMID:19671475

  2. In situ intracellular spectroscopy with surface enhanced Raman spectroscopy (SERS)-enabled nanopipettes.

    PubMed

    Vitol, Elina A; Orynbayeva, Zulfiya; Bouchard, Michael J; Azizkhan-Clifford, Jane; Friedman, Gary; Gogotsi, Yury

    2009-11-24

    We report on a new analytical approach to intracellular chemical sensing that utilizes a surface-enhanced Raman spectroscopy (SERS)-enabled nanopipette. The probe is comprised of a glass capillary with a 100-500 nm tip coated with gold nanoparticles. The fixed geometry of the gold nanoparticles allows us to overcome the limitations of the traditional approach for intracellular SERS using metal colloids. We demonstrate that the SERS-enabled nanopipettes can be used for in situ analysis of living cell function in real time. In addition, SERS functionality of these probes allows tracking of their localization in a cell. The developed probes can also be applied for highly sensitive chemical analysis of nanoliter volumes of chemicals in a variety of environmental and analytical applications.

  3. Target annihilation by diffusing particles in inhomogeneous geometries

    NASA Astrophysics Data System (ADS)

    Cassi, Davide

    2009-09-01

    The survival probability of immobile targets annihilated by a population of random walkers on inhomogeneous discrete structures, such as disordered solids, glasses, fractals, polymer networks, and gels, is analytically investigated. It is shown that, while it cannot in general be related to the number of distinct visited points as in the case of homogeneous lattices, in the case of bounded coordination numbers its asymptotic behavior at large times can still be expressed in terms of the spectral dimension d˜ and its exact analytical expression is given. The results show that the asymptotic survival probability is site-independent of recurrent structures (d˜≤2) , while on transient structures (d˜>2) it can strongly depend on the target position, and such dependence is explicitly calculated.

  4. Study on construction technology of metro tunnel under a glass curtain wall

    NASA Astrophysics Data System (ADS)

    Zhang, Jian; Yu, Deqiang

    2018-03-01

    To ensure the safety of the glass curtain wall building above loess tunnel and get an optimal scheme, an elastic-plastic FEM model is established to simulate three reinforcement schemes based on a tunnel section in Xi’an Metro Line 3. The results show that the settlement value of the optimal scheme is reduced by 69.89% compared with the drainage measures, and the uneven settlement value is reduced by 57.5%. The construction points, technical processes and technical indexes of the optimal scheme are introduced. According to the actual project, the cumulative settlement of the building under construction is 16mm, which meets the control standards. According to the actual project, the cumulative settlement of the glass curtain wall building is 16mm, which meets the control standards. The reinforcement scheme can provide some reference for the design and construction of the metro in loess area.

  5. Four-time 7Li stimulated-echo spectroscopy for the study of dynamic heterogeneities: Application to lithium borate glass.

    PubMed

    Storek, M; Tilly, J F; Jeffrey, K R; Böhmer, R

    2017-09-01

    To study the nature of the nonexponential ionic hopping in solids a pulse sequence was developed that yields four-time stimulated-echo functions of previously inaccessible spin-3/2-nuclei such as 7 Li. It exploits combined Zeeman and octupolar order as longitudinal carrier state. Higher-order correlation functions were successfully generated for natural-abundance and isotopically-enriched lithium diborate glasses. Four-time 7 Li measurements are presented and compared with two-time correlation functions. The results are discussed with reference to approaches devised to quantify the degree of nonexponentiality in glass forming systems and evidence for the occurrence of dynamic heterogeneities and dynamic exchange were found. Additional experiments using the 6 Li species illustrate the challenge posed by subensemble selection when the dipolar interactions are not very much smaller than the quadrupolar ones. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Assessment of Transition Element Speciation in Glasses Using a Portable Transmission Ultraviolet-Visible-Near-Infrared (UV-Vis-NIR) Spectrometer.

    PubMed

    Hunault, Myrtille; Lelong, Gérald; Gauthier, Michel; Gélébart, Frédéric; Ismael, Saindou; Galoisy, Laurence; Bauchau, Fanny; Loisel, Claudine; Calas, Georges

    2016-05-01

    A new low-cost experimental setup based on two compact dispersive optical spectrometers has been developed to measure optical absorption transmission spectra over the 350-2500 nm energy range. We demonstrate how near-infrared (NIR) data are essential to identify the coloring species in addition to ultraviolet visible data. After calibration with reference glasses, the use of an original sample stage that maintains the window panel in the vertical position enables the comparison of ancient and modern glasses embedded in a panel from the Sainte-Chapelle of Paris, without any sampling. The spectral resolution enables to observe fine resonances arising in the absorption bands of Cr(3+), and the complementary information obtained in the NIR enables to determine the contribution of Fe(2+), a key indicator of glassmaking conditions. © The Author(s) 2016.

  7. Plastic Polymers for Efficient DNA Microarray Hybridization: Application to Microbiological Diagnostics▿

    PubMed Central

    Zhao, Zhengshan; Peytavi, Régis; Diaz-Quijada, Gerardo A.; Picard, Francois J.; Huletsky, Ann; Leblanc, Éric; Frenette, Johanne; Boivin, Guy; Veres, Teodor; Dumoulin, Michel M.; Bergeron, Michel G.

    2008-01-01

    Fabrication of microarray devices using traditional glass slides is not easily adaptable to integration into microfluidic systems. There is thus a need for the development of polymeric materials showing a high hybridization signal-to-background ratio, enabling sensitive detection of microbial pathogens. We have developed such plastic supports suitable for highly sensitive DNA microarray hybridizations. The proof of concept of this microarray technology was done through the detection of four human respiratory viruses that were amplified and labeled with a fluorescent dye via a sensitive reverse transcriptase PCR (RT-PCR) assay. The performance of the microarray hybridization with plastic supports made of PMMA [poly(methylmethacrylate)]-VSUVT or Zeonor 1060R was compared to that with high-quality glass slide microarrays by using both passive and microfluidic hybridization systems. Specific hybridization signal-to-background ratios comparable to that obtained with high-quality commercial glass slides were achieved with both polymeric substrates. Microarray hybridizations demonstrated an analytical sensitivity equivalent to approximately 100 viral genome copies per RT-PCR, which is at least 100-fold higher than the sensitivities of previously reported DNA hybridizations on plastic supports. Testing of these plastic polymers using a microfluidic microarray hybridization platform also showed results that were comparable to those with glass supports. In conclusion, PMMA-VSUVT and Zeonor 1060R are both suitable for highly sensitive microarray hybridizations. PMID:18784318

  8. A Twofold Comparison between Dual Cure Resin Modified Cement and Glass Ionomer Cement for Orthodontic Band Cementation.

    PubMed

    Attar, Hanaa El; Elhiny, Omnia; Salem, Ghada; Abdelrahman, Ahmed; Attia, Mazen

    2016-12-15

    To test the solubility of dual cure resin modified resin cement in a food simulating solution and the shear bond strength compared to conventional Glass ionomer cement. The materials tested were self-adhesive dual cure resin modified cement and Glass Ionomer (GIC). Twenty Teflon moulds were divided into two groups of tens. The first group was injected and packed with the modified resin cement, the second group was packed with GIC. To test the solubility, each mould was weighed before and after being placed in an analytical reagent for 30 days. The solubility was measured as the difference between the initial and final drying mass. To measure the Shear bond strength, 20 freshly extracted wisdom teeth were equally divided into two groups and embedded in self-cure acrylic resin. Four mm sections of stainless steel bands were cemented to the exposed buccal surfaces of teeth under a constant load of 500 g. Shear bond strength was measured using a computer controlled materials testing machine and the load required to deband the samples was recorded in Newtons. GIC showed significantly higher mean weight loss and an insignificant lower Shear bond strength, compared to dual cure resin Cement. It was found that dual cure resin modified cement was less soluble than glass ionomer cement and of comparable bond strength rendering it more useful clinically for orthodontic band cementation.

  9. The use of glass powder in making batako

    NASA Astrophysics Data System (ADS)

    Nursyamsi, N.; Indrawan, I.

    2018-02-01

    Along with the increase in construction materials, innovation is needed to lessen the use of them, and one of them is by using cement [1]. In this research, it is reduced by glass powder; the reason for using it as the substitution of cement is that some chemical elements in cement are similar to those in glass powder such as SiO2, A12o3, Fe2O3, and CaO. The glass powder used was the one who passed sieve no. 100 and was hampered in sieve no. 200. It passed sieve no. 200 with its composition of 0%, 10%, 15%, 20%, 25%, and 30% from the volume of the use of cement. The specimen would treat within 28 days before the testing of compressive strength, water absorption, and tensile strength [2]. The variation which produced optimum result would mix with the foaming agent as the material for reducing the weight of the specimen. After that, the test of compressive strength, water absorption, and tensile strength on the installment of batako walls were done. The data analyzed by using SNI 02-0349-1989[3] reference about concrete brick for wall installment. The variation of 20% of glass powder passing sieve no. 200 gave optimum result. A specimen of the variation on glass powder of 20% which passed sieve no. 200 and the foaming agent was higher than the compressive strength of the specimen which used glass powder substitution of 0% of passing sieve no. 200 and foaming agent. The compressive strength of batako walls which used the batako construction with glass powder substitution of 20% of passing sieve no. 200 and the foaming agent was also higher than the compressive strength of the assaying object which used glass powder substitution of 0% of passing sieve no. 200 and foaming agent.

  10. Medical imaging scintillators from glass-ceramics using mixed rare-earth halides

    NASA Astrophysics Data System (ADS)

    Beckert, M. Brooke; Gallego, Sabrina; Ding, Yong; Elder, Eric; Nadler, Jason H.

    2016-10-01

    Recent years have seen greater interest in developing new luminescent materials to replace scintillator panels currently used in medical X-ray imaging systems. The primary areas targeted for improvement are cost and image resolution. Cost reduction is somewhat straightforward in that less expensive raw materials and processing methods will yield a less expensive product. The path to improving image resolution is more complex because it depends on several properties of the scintillator material including density, transparency, and composition, among others. The present study focused on improving image resolution using composite materials, known as glass-ceramics that contain nanoscale scintillating crystallites formed within a transparent host glass matrix. The small size of the particles and in-situ precipitation from the host glass are key to maintaining transparency of the composite scintillator, which ensures that a majority of the light produced from absorbed X-rays can actually be used to create an image of the patient. Because light output is the dominating property that determines the image resolution achievable with a given scintillator, it was used as the primary metric to evaluate performance of the glass-ceramics relative to current scintillators. Several glass compositions were formulated and then heat treated in a step known as "ceramization" to grow the scintillating nanocrystals, whose light output was measured in response to a 65 kV X-ray source. Performance was found to depend heavily on the thermal history of the glass and glass-ceramic, and so additional studies are required to more precisely determine optimal process temperatures. Of the compositions investigated, an alumino-borosilicate host glass containing 56mol% scintillating rare-earth halides (BaF2, GdF3, GdBr3, TbF3) produced the highest recorded light output at nearly 80% of the value recorded using a commercially-available GOS:Tb panel as a reference.

  11. INTEGRATING BIOANALYTICAL CAPABILITY IN AN ENVIRONMENTAL ANALYTICAL LABORATORY

    EPA Science Inventory

    The product is a book chapter which is an introductory and summary chapter for the reference work "Immunoassays and Other Bianalytical Techniques" to be published by CRC Press, Taylor and Francis Books. The chapter provides analytical chemists information on new techni...

  12. Recent developments in OLED-based chemical and biological sensors

    NASA Astrophysics Data System (ADS)

    Shinar, Joseph; Zhou, Zhaoqun; Cai, Yuankun; Shinar, Ruth

    2007-09-01

    Recent developments in the structurally integrated OLED-based platform of luminescent chemical and biological sensors are reviewed. In this platform, an array of OLED pixels, which is structurally integrated with the sensing elements, is used as the photoluminescence (PL) excitation source. The structural integration is achieved by fabricating the OLED array and the sensing element on opposite sides of a common glass substrate or on two glass substrates that are attached back-to-back. As it does not require optical fibers, lens, or mirrors, it results in a uniquely simple, low-cost, and potentially rugged geometry. The recent developments on this platform include the following: (1) Enhancing the performance of gas-phase and dissolved oxygen sensors. This is achieved by (a) incorporating high-dielectric TiO II nanoparticles in the oxygen-sensitive Pt and Pd octaethylporphyrin (PtOEP and PdOEP, respectively)- doped polystyrene (PS) sensor films, and (b) embedding the oxygen-sensitive dyes in a matrix of polymer blends such as PS:polydimethylsiloxane (PDMS). (2) Developing sensor arrays for simultaneous detection of multiple serum analytes, including oxygen, glucose, lactate, and alcohol. The sensing element for each analyte consists of a PtOEP-doped PS oxygen sensor, and a solution containing the oxidase enzyme specific to the analyte. Each sensing element is coupled to two individually addressable OLED pixels and a Si photodiode photodetector (PD). (3) Enhancing the integration of the platform, whereby a PD array is also structurally integrated with the OLED array and sensing elements. This enhanced integration is achieved by fabricating an array of amorphous or nanocrystalline Si-based PDs, followed by fabrication of the OLED pixels in the gaps between these Si PDs.

  13. [Biological effects of artificial mineral fibers].

    PubMed

    Woźniak, H

    1989-01-01

    The present review paper was prepared on the basis of 52 source-books devoted to experimental investigations. Principal conclusions emerging from the experiments described in the references quoted are as follows. MMMF retention in alveoli is conditioned mainly by the fibres size--for fibres of constant dimater retention increases proportionally to their length, while long and thin fibres undergo degradation in fluids much more easily than the short and thick ones. Fibrous effect of glass fibres and glass wool is less remarkable than that of chrysotile and crocidolite; after exposure to glass fibre and wool has stopped, no progress of fibrous changes in animals was observed. In animals exposed to grass fibre or mineral wool through inhalation, the increase in cancer rate was not statistically significant; glass fibres introduced into the pleura showed a weaker tendency to induce neoplasms than the same amount of asbestos fibres, while basalt and ceramic wool induced reaction similar to that provoked by asbestos. In the case of combined exposure glass fibres intensified the toxic effect of styrene in mice and enhanced the incidence of lung cancer in rats exposed to radon. In in vitro study the destructive effect represented the distribution function of fibres size--long fibres (less than 10 microns) and thin fibres (less than 1 micron diameter) demonstrated stronger toxic effect. Glass fibres provoked neither mutations in bacterial test, nor sister chromatid exchange in animal cells in vitro. However, they caused mitosis delay and structural changes in chromosomes.

  14. Degradation of partially immersed glass: A new perspective

    NASA Astrophysics Data System (ADS)

    Chinnam, R. K.; Fossati, P. C. M.; Lee, W. E.

    2018-05-01

    The International Simple Glass (ISG) is a six-component borosilicate glass which was developed as a reference for international collaborative studies on high level nuclear waste encapsulation. Its corrosion behaviour is typically examined when it is immersed in a leaching solution, or when it is exposed to water vapour. In this study, an alternative situation is considered in which the glass is only partially immersed for 7 weeks at a temperature of 90 °C. In this case, half of the glass sample is directly in the solution itself, and the other half is in contact with a water film formed by condensation of water vapour that evaporated from the solution. This results in a different degradation behaviour compared to standard tests in which the material is fully immersed. In particular, whilst in standard tests the system reaches a steady state with a very low alteration rate thanks to the formation of a protective gel layer, in partially-immersed tests this steady state could not be reached because of the continuous alteration from the condensate water film. The constant input of ions from the emerged part of the sample caused a supersaturation of the solution, which resulted in early precipitation of secondary crystalline phases. This setup mimics storage conditions once small amounts of water have entered a glass waste form containing canister. It offers a more realistic outlook of corrosion mechanisms happening in such situations than standard fully-immersed corrosion tests.

  15. Pseudopotential calculations and photothermal lensing measurements of two-photon absorption in solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, W.T. III

    1985-11-04

    We have studied two-photon absorption in solids theoretically and experimentally. We have shown that it is possible to use accurate band structure techniques to compute two-photon absorption spectra within 15% of measured values in a wide band-gap material, ZnS. The empirical pseudopotential technique that we used is significantly more accurate than previous models of two-photon absorption in zinc blende materials, including present tunneling theories (which are essentially parabolic-band results in disguise) and the nonparabolic-band formalism of Pidgeon et al. and Weiler. The agreement between our predictions and previous measurements allowed us to use ZnS as a reference material in ordermore » to validate a technique for measuring two-photon absorption that was previously untried in solids, pulsed dual-beam thermal lensing. With the validated technique, we examined nonlinear absorption in one other crystal (rutile) and in several glasses, including silicates, borosilicates, and one phosphate glass. Initially, we believed that the absorption edges of all the materials were comparable; however, subsequent evidence suggested that the effective band-gap energies of the glasses were above the energy of two photons in our measurement. Therefore, we attribute the nonlinear absorption that we observed in glasses to impurities or defects. The measured nonlinear absorption coefficients were of the order of a few cm/TW in the glasses and of the order of 10 cm/GW in the crystals, four orders of magnitude higher than in glasses. 292 refs.« less

  16. Assessment and forensic application of laser-induced breakdown spectroscopy (LIBS) for the discrimination of Australian window glass.

    PubMed

    El-Deftar, Moteaa M; Speers, Naomi; Eggins, Stephen; Foster, Simon; Robertson, James; Lennard, Chris

    2014-08-01

    A commercially available laser-induced breakdown spectroscopy (LIBS) instrument was evaluated for the determination of elemental composition of twenty Australian window glass samples, consisting of 14 laminated samples and 6 non-laminated samples (or not otherwise specified) collected from broken windows at crime scenes. In this study, the LIBS figures of merit were assessed in terms of accuracy, limits of detection and precision using three standard reference materials (NIST 610, 612, and 1831). The discrimination potential of LIBS was compared to that obtained using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), X-ray microfluorescence spectroscopy (μXRF) and scanning electron microscopy energy dispersive X-ray spectrometry (SEM-EDX) for the analysis of architectural window glass samples collected from crime scenes in the Canberra region, Australia. Pairwise comparisons were performed using a three-sigma rule, two-way ANOVA and Tukey's HSD test at 95% confidence limit in order to investigate the discrimination power for window glass analysis. The results show that the elemental analysis of glass by LIBS provides a discrimination power greater than 97% (>98% when combined with refractive index data), which was comparable to the discrimination powers obtained by LA-ICP-MS and μXRF. These results indicate that LIBS is a feasible alternative to the more expensive LA-ICP-MS and μXRF options for the routine forensic analysis of window glass samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Training Guidelines. Operatives-Precast Concrete.

    ERIC Educational Resources Information Center

    Ceramics, Glass, and Mineral Products Industry Training Board, Harrow (England).

    This manual is intended to provide guidelines for firms in the precast concrete industry in planning their training programs particularly with reference to new entrants into the industry. Details for preparing training syllabuses for various job specifications are given--mould makers in timber, steel, and glass fiber; makers; finishers; site…

  18. 78 FR 41846 - Approval and Promulgation of Implementation Plans; New York State Ozone Implementation Plan Revision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-12

    ... production plants. These control requirements will be specifically aimed at reducing NO X emissions resulting... Environmental protection, Air pollution control, Hydrocarbons, Incorporation by reference, Intergovernmental..., ``Portland Cement Plants and Glass Plants,'' and Subpart 227-2, ``Reasonably Available Control Technology...

  19. U-Pb Dating of Calcite by LA-ICPMS

    NASA Astrophysics Data System (ADS)

    Hacker, B. R.; Kylander-Clark, A. R.; Holder, R. M.; Nuriel, P.

    2016-12-01

    An emerging frontier area in geochronology is U-Pb dating of carbonate minerals by laser-ablation inductively coupled plasma mass spectrometry (LA-ICPMS). The spate of papers over the last few years applying LA-ICPMS to carbonate dating stems from the capability of LA-ICPMS to deal with the variable, and often low, U/Pb ratios of carbonate. LA-ICPMS is an excellent tool for efficiently screening out samples with low U/Pb ratios and provides the ability to measure many spots with different U/Pb ratios and obtain dates free of assumptions about the composition of common Pb. Because this technique is in its infancy, important questions remain. What percentage of carbonate samples have high enough U/Pbc ratios that they can be dated? What percentage of samples yield isochronous datasets? What are the limits on precision and accuracy of carbonate U/Pb dates? What is the best analytical method in the absence of isotopically homogeneous reference materials? Through the generosity of our colleagues we have acquired 8 reference materials ranging in age from 3 to 250 Ma. We have analyzed 125 unknowns from a variety of locations using a 193 nm ns laser with an 80-100 μm spot and a Nu Plasma HR-ES. We measure 207Pb/206Pb using NIST 614 glass and then calculate a 206Pb/238U correction factor based on the measured vs. known ages of the reference materials. Sixty of these samples ( 50%) have high enough U/Pb ratios that they can be dated. There is great heterogeneity among the sample suites: some have no datable samples, whereas one suite of 68 samples yielded 53 datable rocks. Of the samples with high U/Pbc ratios, a majority yielded isochronous U-Pb data, indicating that the U-Pb system closed at a given time and was not subsequently disturbed.

  20. Big Data Analytics for a Smart Green Infrastructure Strategy

    NASA Astrophysics Data System (ADS)

    Barrile, Vincenzo; Bonfa, Stefano; Bilotta, Giuliana

    2017-08-01

    As well known, Big Data is a term for data sets so large or complex that traditional data processing applications aren’t sufficient to process them. The term “Big Data” is referred to using predictive analytics. It is often related to user behavior analytics, or other advanced data analytics methods which from data extract value, and rarely to a particular size of data set. This is especially true for the huge amount of Earth Observation data that satellites constantly orbiting the earth daily transmit.

  1. Matt waste from glass separated collection: an eco-sustainable addition for new building materials.

    PubMed

    Bignozzi, M C; Saccani, A; Sandrolini, F

    2009-01-01

    Matt waste (MW), a by-product of purification processes of cullet derived from separated glass waste collection, has been studied as filler for self-compacting concrete and as an addition for newly blended cement. Properties of self-compacting concrete compared to reference samples are reported. They include characteristics at the fresh and hardened states, and the compressive strength and porosity of mortar samples that were formulated with increasing amounts of MW to be used as cement replacement (up to 50wt.%). The effects of matt waste are discussed with respect to the mechanical and microstructural characteristics of the resulting new materials.

  2. Emotions in action through the looking glass.

    PubMed

    Sinigaglia, Corrado; Sparaci, Laura

    2010-02-01

    The paper aims at highlighting how our primary understanding of others' actions is rooted in the mirror mechanism. To this end, the anatomical architecture of the mirror neuron system for action will be outlined as well as its role in grasping goals and intentions in others' motor behaviour. One further step through the looking glass of social cognition will be referring to the ubiquitous emotional colouring of actions and considering its links with the motor domain. This will allow a clearer perspective on the mechanism underlying our abilities for emotional understanding and on cases in which these abilities are amiss, as in autistic spectrum disorders.

  3. Reference electrode for strong oxidizing acid solutions

    DOEpatents

    Rigdon, Lester P.; Harrar, Jackson E.; Bullock, Sr., Jack C.; McGuire, Raymond R.

    1990-01-01

    A reference electrode for the measurement of the oxidation-reduction potentials of solutions is especially suitable for oxidizing solutions such as highly concentrated and fuming nitric acids, the solutions of nitrogen oxides, N.sub.2 O.sub.4 and N.sub.2 O.sub.5, in nitric acids. The reference electrode is fabricated of entirely inert materials, has a half cell of Pt/Ce(IV)/Ce(III)/70 wt. % HNO.sub.3, and includes a double-junction design with an intermediate solution of 70 wt. % HNO.sub.3. The liquid junctions are made from Corning No. 7930 glass for low resistance and negligible solution leakage.

  4. Forensic investigation of plutonium metal: a case study of CRM 126

    DOE PAGES

    Byerly, Benjamin L.; Stanley, Floyd; Spencer, Khal; ...

    2016-11-01

    In our study, a certified plutonium metal reference material (CRM 126) with a known production history is examined using analytical methods that are commonly employed in nuclear forensics for provenancing and attribution. Moreover, the measured plutonium isotopic composition and actinide assay are consistent with values reported on the reference material certificate. Model ages from U/Pu and Am/Pu chronometers agree with the documented production timeline. Finally, these results confirm the utility of these analytical methods and highlight the importance of a holistic approach for forensic study of unknown materials.

  5. Analytical Chemistry: A Literary Approach

    NASA Astrophysics Data System (ADS)

    Lucy, Charles A.

    2000-04-01

    The benefits of incorporating real-world examples of chemistry into lectures and lessons is reflected by the recent inclusion of the Teaching with Problems and Case Studies column in this Journal. However, these examples lie outside the experience of many students, and so much of the impact of "real-world" examples is lost. This paper provides an anthology of references to analytical chemistry techniques from history, popular fiction, and film. Such references are amusing to both instructor and student. Further, the fictional descriptions can serve as a focal point for discussions of a technique's true capabilities and limitations.

  6. Development of Standard Reference Materials to support assessment of iodine status for nutritional and public health purposes.

    PubMed

    Long, Stephen E; Catron, Brittany L; Boggs, Ashley Sp; Tai, Susan Sc; Wise, Stephen A

    2016-09-01

    The use of urinary iodine as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in urine. Likewise, the use of dietary iodine intake as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in dietary sources, including foods and dietary supplements. Similarly, the use of specific serum biomarkers of thyroid function to screen for both iodine deficiency and iodine excess relies in part on the accuracy of the analytical measurement of those biomarkers. The National Institute of Standards and Technology has been working with the NIH Office of Dietary Supplements for several years to develop higher-order reference measurement procedures and Standard Reference Materials to support the validation of new routine analytical methods for iodine in foods and dietary supplements, for urinary iodine, and for several serum biomarkers of thyroid function including thyroid-stimulating hormone, thyroglobulin, total and free thyroxine, and total and free triiodothyronine. These materials and methods have the potential to improve the assessment of iodine status and thyroid function in observational studies and clinical trials, thereby promoting public health efforts related to iodine nutrition. © 2016 American Society for Nutrition.

  7. Uptake of recommended common reference intervals for chemical pathology in Australia.

    PubMed

    Jones, Graham Rd; Koetsier, Sabrina

    2017-05-01

    Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.

  8. Nucleation and crystal growth behavior of nepheline in simulated high-level waste glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K.; Amoroso, J.; Mcclane, D.

    The Savannah River National Laboratory (SRNL) has been tasked with supporting glass formulation development and process control strategies in key technical areas, relevant to the Department of Energy’s Office of River Protection (DOE-ORP) and related to high-level waste (HLW) vitrification at the Waste Treatment and Immobilization Plant (WTP). Of specific interest is the development of predictive models for crystallization of nepheline (NaAlSiO4) in HLW glasses formulated at high alumina concentrations. This report summarizes recent progress by researchers at SRNL towards developing a predicative tool for quantifying nepheline crystallization in HLW glass canisters using laboratory experiments. In this work, differential scanningmore » calorimetry (DSC) was used to obtain the temperature regions over which nucleation and growth of nepheline occur in three simulated HLW glasses - two glasses representative of WTP projections and one glass representative of the Defense Waste Processing Facility (DWPF) product. The DWPF glass, which has been studied previously, was chosen as a reference composition and for comparison purposes. Complementary quantitative X-ray diffraction (XRD) and optical microscopy confirmed the validity of the methodology to determine nucleation and growth behavior as a function of temperature. The nepheline crystallization growth region was determined to generally extend from ~ 500 to >850 °C, with the maximum growth rates occurring between 600 and 700 °C. For select WTP glass compositions (high Al2O3 and B2O3), the nucleation range extended from ~ 450 to 600 °C, with the maximum nucleation rates occurring at ~ 530 °C. For the DWPF glass composition, the nucleation range extended from ~ 450 to 750 °C with the maximum nucleation rate occurring at ~ 640 °C. The nepheline growth at the peak temperature, as determined by XRD, was between 35 - 75 wt.% /hour. A maximum nepheline growth rate of ~ 0.1 mm/hour at 700 °C was measured for the DWPF composition using optical microscopy. This research establishes a viable alternative to more traditional techniques for evaluating nepheline crystallization in large numbers of glasses, which are prohibitively time consuming or otherwise impractical. The ultimate objective is to combine the nucleation and growth information obtained from DSC, like that presented in this report, with computer simulations of glass cooling within the canister to accurately predict nepheline crystallization in HLW during processing through WTP.« less

  9. Plasma biochemical and PCV ranges for healthy, wild, immature hawksbill (Eretmochelys imbricata) sea turtles.

    PubMed

    Whiting, S D; Guinea, M L; Fomiatti, K; Flint, M; Limpus, C J

    2014-06-14

    In recent years, the use of blood chemistry as a diagnostic tool for sea turtles has been demonstrated, but much of its effectiveness relies on reference intervals. The first comprehensive blood chemistry values for healthy wild hawksbill (Eretmochelys imbricata) sea turtles are presented. Nineteen blood chemistry analytes and packed cell volume were analysed for 40 clinically healthy juvenile hawksbill sea turtles captured from a rocky reef habitat in northern Australia. We used four statistical approaches to calculate reference intervals and to investigate their use with non-normal distributions and small sample sizes, and to compare upper and lower limits between methods. Eleven analytes were correlated with curved carapace length indicating that body size should be considered when designing future studies and interpreting analyte values. British Veterinary Association.

  10. The Algorithm for MODIS Wavelength On-Orbit Calibration Using the SRCA

    NASA Technical Reports Server (NTRS)

    Montgomery, Harry; Che, Nianzeng; Parker, Kirsten; Bowser, Jeff

    1998-01-01

    The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didymium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, Beta (half angle between the incident and diffractive beams) and Theta(sub off) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing.

  11. A numerical approximation to the elastic properties of sphere-reinforced composites

    NASA Astrophysics Data System (ADS)

    Segurado, J.; Llorca, J.

    2002-10-01

    Three-dimensional cubic unit cells containing 30 non-overlapping identical spheres randomly distributed were generated using a new, modified random sequential adsortion algorithm suitable for particle volume fractions of up to 50%. The elastic constants of the ensemble of spheres embedded in a continuous and isotropic elastic matrix were computed through the finite element analysis of the three-dimensional periodic unit cells, whose size was chosen as a compromise between the minimum size required to obtain accurate results in the statistical sense and the maximum one imposed by the computational cost. Three types of materials were studied: rigid spheres and spherical voids in an elastic matrix and a typical composite made up of glass spheres in an epoxy resin. The moduli obtained for different unit cells showed very little scatter, and the average values obtained from the analysis of four unit cells could be considered very close to the "exact" solution to the problem, in agreement with the results of Drugan and Willis (J. Mech. Phys. Solids 44 (1996) 497) referring to the size of the representative volume element for elastic composites. They were used to assess the accuracy of three classical analytical models: the Mori-Tanaka mean-field analysis, the generalized self-consistent method, and Torquato's third-order approximation.

  12. Heterogeneous photo-oxidation of pesticides and its implication to their environmental fate

    NASA Astrophysics Data System (ADS)

    Dubowski, Y.

    2014-12-01

    The environmental fate and impact of pesticides strongly depend on their post application degradation processes. While most existing knowledge on pesticides degradation refers to processes within bulk soil and water, applied pesticides may remain on treated surfaces (and on airborn particles) for long duration, exposed to atmospheric oxidants and solar radiation. The resulting photo-oxidation processes may have significant effect on their fate, especially in semiarid regions where pesticide applications take place during the long dry season and targeted irrigation is common. Here we present our studies on heterogeneous photo-oxidation of few commonly used pesticides (e.g., cypermethrin, methyl parathion, and chlorpyrifos), using novel laboratory setups enabling simultaneous monitoring of both phases. Experiments focused on kinetics, quantum yields, and identification of gaseous and condensed products. In addition, the reactivity of the selected pesticides was investigated as a function of their matrix (analytical vs. commercial formula), their phase (thin film vs. airborne aerosols), and the substrate they are sorbed on (leaf, soil, and glass). Complimentarily to these laboratory studies, field measurements of selected pesticides concentrations in few streams in northern Israel during the first rain events were also conducted and showed the important role of surface processes on these pesticides fate and transport in semi-arid climate.

  13. Precise and accurate in situ Pb-Pb dating of apatite, monazite, and sphene by laser ablation multiple-collector ICP-MS

    NASA Astrophysics Data System (ADS)

    Willigers, B. J. A.; Baker, J. A.; Krogstad, E. J.; Peate, D. W.

    2002-03-01

    To evaluate in situ Pb dating by laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS), we analysed apatite, sphene, and monazite from Paleoproterozoic metamorphic rocks from West Greenland. Pb isotope ratios were also determined in the National Institute of Standards and Technology (NIST) 610 glass standard and were corrected for mass fractionation by reference to the measured thallium isotope ratio. The NIST 610 glass was used to monitor Pb isotope mass fractionation in the low Tl/Pb accessory minerals. Replicate analyses of the glass (1 to 2 min) yielded ratios with an external reproducibility comparable to conventional analyses of standard reference material 981 by thermal ionisation mass spectrometry (TIMS). Mineral grains were generally analysed with a 100-μm laser beam, although some monazite crystals were analysed at smaller spot sizes (10 and 25 μm). The common Pb isotope ratios required for age calculations were either measured on coexisting plagioclase by LA-MC-ICP-MS or could be ignored, as individual crystals exhibit sufficient Pb isotopic heterogeneity to perform isochron calculations on replicate analyses of single crystals. Mean mineral ages with the 204Pb ion beam measured in the multiplier were as follows: apatite, 1715 ± 23 m.y.; sphene, 1789 ± 11 m.y.; and monazite, 1783 to 1888 m.y., with relative uncertainties on individual monazite ages of <0.2% but highly reproducible age determinations on single monazite crystals (≪1%). Isochron ages calculated from several mineral analyses without assumption of common Pb also yield precise age determinations. Apatite and monazite Pb ages determined by in situ Pb isotope analysis are identical to those determined by conventional TIMS analysis of bulk mineral separates, and the analytical uncertainties of these short laser analyses with no prior mechanical or chemical separation are comparable to those obtained by TIMS. Detailed examination of the sphene in situ age data does, however, show a small discrepancy between the LA-MC-ICP-MS and TIMS ages (˜1% younger). High-resolution mass scans of the sphene during ablation clearly showed several small and as yet unidentified isobaric interferences that overlap with the 207Pb peak at the resolution conditions for measurement of isotope ratios. These might account for the age discrepancy between the LA-MC-ICP-MS and TIMS sphene ages. LA-MC-ICP-MS is a rapid, accurate, and precise method for in situ determination of Pb isotope ratios that can be used for geochronological studies in a manner similar to an ion microprobe, albeit currently at a somewhat degraded spatial resolution. Further modifications to the LA-MC-ICP-MS system, such as improved sensitivity, ion transmission, and LA methodology, may lead to this type of instrument becoming the method of choice for many types of in situ Pb isotope dating.

  14. AN EQUATORIAL PACIFIC RAIN EVENT: INFLUENCE ON THE DISTRIBUTION OF IRON AND HYDROGEN PEROXIDE IN SURFACE WATERS

    EPA Science Inventory

    Methods are described for measuring changes in atmospheric O2 concentration with emphasis on gas handling procedures. Cryogenically dried air samples are collected in 5 L glass flasks at ambient pressure and analyzed against reference gases derived from high-pressure aluminum tan...

  15. Fizz-Ball Fizzics

    ERIC Educational Resources Information Center

    Moinester, Murray; Gerland, Lars; Liger-Belair, Gerard; Ocherashvili, Aharon

    2012-01-01

    We describe the fluid dynamics principles governing the up-down oscillatory cycling of a bubble-covered, low-density, low-mass ball of material (referred to henceforth as a "fizz-ball") immersed inside a glass of bubbling (super-saturated) carbonated liquid. The bubbles serve to desaturate the liquid of excess CO[subscript 2]. The fizz-ball acts…

  16. Female Administrators: A Crack in the Glass Ceiling.

    ERIC Educational Resources Information Center

    Reis, Susan Bon; Young, I. Phillip; Jury, James C.

    1999-01-01

    Studied the effects of evaluator gender, applicant gender, and gender of the reference source on the screening of applicants for assistant-principal positions. Responses of 150 high school principals suggest that hypothetical female candidates were evaluated more highly than male applicants and were more likely to be interviewed. (SLD)

  17. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.

    PubMed

    Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow

    2018-03-01

    Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. A microarray immunoassay for simultaneous detection of proteins and bacteria

    NASA Technical Reports Server (NTRS)

    Delehanty, James B.; Ligler, Frances S.

    2002-01-01

    We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).

  19. SiO_{2} Glass Density to Lower-Mantle Pressures.

    PubMed

    Petitgirard, Sylvain; Malfait, Wim J; Journaux, Baptiste; Collings, Ines E; Jennings, Eleanor S; Blanchard, Ingrid; Kantor, Innokenty; Kurnosov, Alexander; Cotte, Marine; Dane, Thomas; Burghammer, Manfred; Rubie, David C

    2017-11-24

    The convection or settling of matter in the deep Earth's interior is mostly constrained by density variations between the different reservoirs. Knowledge of the density contrast between solid and molten silicates is thus of prime importance to understand and model the dynamic behavior of the past and present Earth. SiO_{2} is the main constituent of Earth's mantle and is the reference model system for the behavior of silicate melts at high pressure. Here, we apply our recently developed x-ray absorption technique to the density of SiO_{2} glass up to 110 GPa, doubling the pressure range for such measurements. Our density data validate recent molecular dynamics simulations and are in good agreement with previous experimental studies conducted at lower pressure. Silica glass rapidly densifies up to 40 GPa, but the density trend then flattens to become asymptotic to the density of SiO_{2} minerals above 60 GPa. The density data present two discontinuities at ∼17 and ∼60  GPa that can be related to a silicon coordination increase from 4 to a mixed 5/6 coordination and from 5/6 to sixfold, respectively. SiO_{2} glass becomes denser than MgSiO_{3} glass at ∼40  GPa, and its density becomes identical to that of MgSiO_{3} glass above 80 GPa. Our results on SiO_{2} glass may suggest that a variation of SiO_{2} content in a basaltic or pyrolitic melt with pressure has at most a minor effect on the final melt density, and iron partitioning between the melts and residual solids is the predominant factor that controls melt buoyancy in the lowermost mantle.

  20. SiO2 Glass Density to Lower-Mantle Pressures

    NASA Astrophysics Data System (ADS)

    Petitgirard, Sylvain; Malfait, Wim J.; Journaux, Baptiste; Collings, Ines E.; Jennings, Eleanor S.; Blanchard, Ingrid; Kantor, Innokenty; Kurnosov, Alexander; Cotte, Marine; Dane, Thomas; Burghammer, Manfred; Rubie, David C.

    2017-11-01

    The convection or settling of matter in the deep Earth's interior is mostly constrained by density variations between the different reservoirs. Knowledge of the density contrast between solid and molten silicates is thus of prime importance to understand and model the dynamic behavior of the past and present Earth. SiO2 is the main constituent of Earth's mantle and is the reference model system for the behavior of silicate melts at high pressure. Here, we apply our recently developed x-ray absorption technique to the density of SiO2 glass up to 110 GPa, doubling the pressure range for such measurements. Our density data validate recent molecular dynamics simulations and are in good agreement with previous experimental studies conducted at lower pressure. Silica glass rapidly densifies up to 40 GPa, but the density trend then flattens to become asymptotic to the density of SiO2 minerals above 60 GPa. The density data present two discontinuities at ˜17 and ˜60 GPa that can be related to a silicon coordination increase from 4 to a mixed 5 /6 coordination and from 5 /6 to sixfold, respectively. SiO2 glass becomes denser than MgSiO3 glass at ˜40 GPa , and its density becomes identical to that of MgSiO3 glass above 80 GPa. Our results on SiO2 glass may suggest that a variation of SiO2 content in a basaltic or pyrolitic melt with pressure has at most a minor effect on the final melt density, and iron partitioning between the melts and residual solids is the predominant factor that controls melt buoyancy in the lowermost mantle.

Top