The field analytical screening program (FASP) polychlorinated biphenyl (PCB) method uses a temperature-programmable gas chromatograph (GC) equipped with an electron capture detector (ECD) to identify and quantify PCBs. Gas chromatography is an EPA-approved method for determi...
FIELD ANALYTICAL SCREENING PROGRAM: PCP METHOD - INNOVATIVE TECHNOLOGY EVALUATION REPORT
The Field Analytical Screening Program (FASP) pentachlorophenol (PCP) method uses a gas chromatograph (GC) equipped with a megabore capillary column and flame ionization detector (FID) and electron capture detector (ECD) to identify and quantify PCP. The FASP PCP method is design...
FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - INNOVATIVE TECHNOLOGY REPORT
This innovative technology evaluation report (ITER) presents information on the demonstration of the U.S. Environmental Protection Agency (EPA) Region 7 Superfund Field Analytical Screening Program (FASP) method for determining polychlorinated biphenyl (PCB) contamination in soil...
Zhang, Wei; Huang, Guangming
2015-11-15
Approaches for analyte screening have been used to aid in the fine-tuning of chemical reactions. Herein, we present a simple and straightforward analyte screening method for chemical reactions via reactive low-temperature plasma ionization mass spectrometry (reactive LTP-MS). Solution-phase reagents deposited on sample substrates were desorbed into the vapor phase by action of the LTP and by thermal desorption. Treated with LTP, both reagents reacted through a vapor phase ion/molecule reaction to generate the product. Finally, protonated reagents and products were identified by LTP-MS. Reaction products from imine formation reaction, Eschweiler-Clarke methylation and the Eberlin reaction were detected via reactive LTP-MS. Products from the imine formation reaction with reagents substituted with different functional groups (26 out of 28 trials) were successfully screened in a time of 30 s each. Besides, two short-lived reactive intermediates of Eschweiler-Clarke methylation were also detected. LTP in this study serves both as an ambient ionization source for analyte identification (including reagents, intermediates and products) and as a means to produce reagent ions to assist gas-phase ion/molecule reactions. The present reactive LTP-MS method enables fast screening for several analytes from several chemical reactions, which possesses good reagent compatibility and the potential to perform high-throughput analyte screening. In addition, with the detection of various reactive intermediates (intermediates I and II of Eschweiler-Clarke methylation), the present method would also contribute to revealing and elucidating reaction mechanisms. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Tegart, J. R.; Aydelott, J. C.
1978-01-01
The design of surface tension propellant acquisition systems using fine-mesh screen must take into account all factors that influence the liquid pressure differentials within the system. One of those factors is spacecraft vibration. Analytical models to predict the effects of vibration have been developed. A test program to verify the analytical models and to allow a comparative evaluation of the parameters influencing the response to vibration was performed. Screen specimens were tested under conditions simulating the operation of an acquisition system, considering the effects of such parameters as screen orientation and configuration, screen support method, screen mesh, liquid flow and liquid properties. An analytical model, based on empirical coefficients, was most successful in predicting the effects of vibration.
Liu, Min; Zhang, Chunsun; Liu, Feifei
2015-09-03
In this work, we first introduce the fabrication of microfluidic cloth-based analytical devices (μCADs) using a wax screen-printing approach that is suitable for simple, inexpensive, rapid, low-energy-consumption and high-throughput preparation of cloth-based analytical devices. We have carried out a detailed study on the wax screen-printing of μCADs and have obtained some interesting results. Firstly, an analytical model is established for the spreading of molten wax in cloth. Secondly, a new wax screen-printing process has been proposed for fabricating μCADs, where the melting of wax into the cloth is much faster (∼5 s) and the heating temperature is much lower (75 °C). Thirdly, the experimental results show that the patterning effects of the proposed wax screen-printing method depend to a certain extent on types of screens, wax melting temperatures and melting time. Under optimized conditions, the minimum printing width of hydrophobic wax barrier and hydrophilic channel is 100 μm and 1.9 mm, respectively. Importantly, the developed analytical model is also well validated by these experiments. Fourthly, the μCADs fabricated by the presented wax screen-printing method are used to perform a proof-of-concept assay of glucose or protein in artificial urine with rapid high-throughput detection taking place on a 48-chamber cloth-based device and being performed by a visual readout. Overall, the developed cloth-based wax screen-printing and arrayed μCADs should provide a new research direction in the development of advanced sensor arrays for detection of a series of analytes relevant to many diverse applications. Copyright © 2015 Elsevier B.V. All rights reserved.
Conventional approaches to water quality characterization can provide data on individual chemical components of each water sample. This analyte-by-analyte approach currently serves many useful research and compliance monitoring needs. However these approaches, which require a ...
Distributed Generation Interconnection Collaborative | NREL
, reduce paperwork, and improve customer service. Analytical Methods for Interconnection Many utilities and jurisdictions are seeking the right screening and analytical methods and tools to meet their reliability
Odoardi, Sara; Fisichella, Marco; Romolo, Francesco Saverio; Strano-Rossi, Sabina
2015-09-01
The increasing number of new psychoactive substances (NPS) present in the illicit market render their identification in biological fluids/tissues of great concern for clinical and forensic toxicology. Analytical methods able to detect the huge number of substances that can be used are sought, considering also that many NPS are not detected by the standard immunoassays generally used for routine drug screening. The aim of this work was to develop a method for the screening of different classes of NPS (a total of 78 analytes including cathinones, synthetic cannabinoids, phenethylamines, piperazines, ketamine and analogues, benzofurans, tryptamines) from blood samples. The simultaneous extraction of analytes was performed by Dispersive Liquid/Liquid Microextraction DLLME, a very rapid, cheap and efficient extraction technique that employs microliters amounts of organic solvents. Analyses were performed by a target Ultrahigh Performance Liquid Chromatography tandem Mass Spectrometry (UHPLC-MS/MS) method in multiple reaction monitoring (MRM). The method allowed the detection of the studied analytes with limits of detection (LODs) ranging from 0.2 to 2ng/mL. The proposed DLLME method can be used as an alternative to classical liquid/liquid or solid-phase extraction techniques due to its rapidity, necessity to use only microliters amounts of organic solvents, cheapness, and to its ability to extract simultaneously a huge number of analytes also from different chemical classes. The method was then applied to 60 authentic real samples from forensic cases, demonstrating its suitability for the screening of a wide number of NPS. Copyright © 2015 Elsevier B.V. All rights reserved.
Sampling and analysis for radon-222 dissolved in ground water and surface water
DeWayne, Cecil L.; Gesell, T.F.
1992-01-01
Radon-222 is a naturally occurring radioactive gas in the uranium-238 decay series that has traditionally been called, simply, radon. The lung cancer risks associated with the inhalation of radon decay products have been well documented by epidemiological studies on populations of uranium miners. The realization that radon is a public health hazard has raised the need for sampling and analytical guidelines for field personnel. Several sampling and analytical methods are being used to document radon concentrations in ground water and surface water worldwide but no convenient, single set of guidelines is available. Three different sampling and analytical methods - bubbler, liquid scintillation, and field screening - are discussed in this paper. The bubbler and liquid scintillation methods have high accuracy and precision, and small analytical method detection limits of 0.2 and 10 pCi/l (picocuries per liter), respectively. The field screening method generally is used as a qualitative reconnaissance tool.
Method of identity analyte-binding peptides
Kauvar, Lawrence M.
1990-01-01
A method for affinity chromatography or adsorption of a designated analyte utilizes a paralog as the affinity partner. The immobilized paralog can be used in purification or analysis of the analyte; the paralog can also be used as a substitute for antibody in an immunoassay. The paralog is identified by screening candidate peptide sequences of 4-20 amino acids for specific affinity to the analyte.
Effect of Vibration on Retention Characteristics of Screen Acquisition Systems
NASA Technical Reports Server (NTRS)
Tegart, J. R.; Park, A. C.
1977-01-01
An analytical and experimental investigation of the effect of vibration on the retention characteristics of screen acquisition systems was performed. The functioning of surface tension devices using fine-mesh screens requires that the pressure differential acting on the screen be less than its pressure retention capability. When exceeded, screen breakdown will occur and gas-free expulsion of propellant will no longer be possible. An analytical approach to predicting the effect of vibration was developed. This approach considers the transmission of the vibration to the screens of the device and the coupling of the liquid and the screen in establishing the screen response. A method of evaluating the transient response of the gas/liquid interface within the screen was also developed.
Method of identity analyte-binding peptides
Kauvar, L.M.
1990-10-16
A method for affinity chromatography or adsorption of a designated analyte utilizes a paralog as the affinity partner. The immobilized paralog can be used in purification or analysis of the analyte; the paralog can also be used as a substitute for antibody in an immunoassay. The paralog is identified by screening candidate peptide sequences of 4--20 amino acids for specific affinity to the analyte. 5 figs.
Manickum, Thavrin; John, Wilson
2015-07-01
The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental requirements for steroid hormone quantitation. Further optimization of the sensitivity of the chemical-analytical LC-tandem mass spectrometry methods, especially for wastewater screening, in South Africa is required. Risk assessment studies showed that it was not practical to propose standards or allowable limits for the steroid estrogens E1, E2, EE2, and E3; the use of predicted-no-effect concentration values of the steroid estrogens appears to be appropriate for use in their risk assessment in relation to aquatic organisms. For raw water sources, drinking water, raw and treated wastewater, the use of bioassays, with trigger values, is a useful screening tool option to decide whether further examination of specific endocrine activity may be warranted, or whether concentrations of such activity are of low priority, with respect to health concerns in the human population. The achievement of improved quantitation limits for immuno-analytical methods, like ELISA, used for compound quantitation, and standardization of the method for measuring E2 equivalents (EEQs) used for biological activity (endocrine: e.g., estrogenic) are some areas for future EDC research.
A screening tool for delineating subregions of steady recharge within groundwater models
Dickinson, Jesse; Ferré, T.P.A.; Bakker, Mark; Crompton, Becky
2014-01-01
We have developed a screening method for simplifying groundwater models by delineating areas within the domain that can be represented using steady-state groundwater recharge. The screening method is based on an analytical solution for the damping of sinusoidal infiltration variations in homogeneous soils in the vadose zone. The damping depth is defined as the depth at which the flux variation damps to 5% of the variation at the land surface. Groundwater recharge may be considered steady where the damping depth is above the depth of the water table. The analytical solution approximates the vadose zone diffusivity as constant, and we evaluated when this approximation is reasonable. We evaluated the analytical solution through comparison of the damping depth computed by the analytic solution with the damping depth simulated by a numerical model that allows variable diffusivity. This comparison showed that the screening method conservatively identifies areas of steady recharge and is more accurate when water content and diffusivity are nearly constant. Nomograms of the damping factor (the ratio of the flux amplitude at any depth to the amplitude at the land surface) and the damping depth were constructed for clay and sand for periodic variations between 1 and 365 d and flux means and amplitudes from nearly 0 to 1 × 10−3 m d−1. We applied the screening tool to Central Valley, California, to identify areas of steady recharge. A MATLAB script was developed to compute the damping factor for any soil and any sinusoidal flux variation.
Screening Methods for Metal-Containing Nanoparticles in Water
Screening-level analysis of water for metal-containing nanoparticles is achieved with single particle-inductively coupled plasma mass spectrometry (SP-ICPMS). This method measures both the concentration of nanoparticles containing an analyte metal and the mass of the metal in eac...
Noguchi, Akio; Nakamura, Kosuke; Sakata, Kozue; Sato-Fukuda, Nozomi; Ishigaki, Takumi; Mano, Junichi; Takabatake, Reona; Kitta, Kazumi; Teshima, Reiko; Kondo, Kazunari; Nishimaki-Mogami, Tomoko
2016-04-19
A number of genetically modified (GM) maize events have been developed and approved worldwide for commercial cultivation. A screening method is needed to monitor GM maize approved for commercialization in countries that mandate the labeling of foods containing a specified threshold level of GM crops. In Japan, a screening method has been implemented to monitor approved GM maize since 2001. However, the screening method currently used in Japan is time-consuming and requires generation of a calibration curve and experimental conversion factor (C(f)) value. We developed a simple screening method that avoids the need for a calibration curve and C(f) value. In this method, ΔC(q) values between the target sequences and the endogenous gene are calculated using multiplex real-time PCR, and the ΔΔC(q) value between the analytical and control samples is used as the criterion for determining analytical samples in which the GM organism content is below the threshold level for labeling of GM crops. An interlaboratory study indicated that the method is applicable independently with at least two models of PCR instruments used in this study.
USDA-ARS?s Scientific Manuscript database
Although quantitative analytical methods must be empirically validated prior to their actual use in a variety of applications, including regulatory monitoring of chemical adulterants in foods, validation of qualitative method performance for the analytes and matrices of interest is frequently ignore...
Lehotay, Steven J; Mastovska, Katerina; Lightfield, Alan R; Nuñez, Alberto; Dutko, Terry; Ng, Chilton; Bluhm, Louis
2013-10-25
A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pipette extraction, and analysis by a 3 min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The drug analytes include neomycin, streptomycin, dihydrosptreptomycin, and spectinomycin, which have residue tolerances in bovine in the US, and kanamicin, gentamicin, apramycin, amikacin, and hygromycin, which do not have US tolerances established in bovine tissues. Tobramycin was used as an internal standard. An additional drug, paromomycin also was validated in the method, but it was dropped during implementation due to conversion of neomycin into paromomycin. Proposed fragmentation patterns for the monitored ions of each analyte were elucidated with the aid of high resolution MS using a quadrupole-time-of-flight instrument. Recoveries from spiking experiments at regulatory levels of concern showed that all analytes averaged 70-120% recoveries in all tissues, except hygromycin averaged 61% recovery. Lowest calibrated levels were as low as 0.005 μg/g in matrix extracts, which approximately corresponded to the limit of detection for screening purposes. Drug identifications at levels <0.05 μg/g were made in spiked and/or real samples for all analytes and tissues tested. Analyses of 60 samples from 20 slaughtered cattle previously screened positive for aminoglycosides showed that this method worked well in practice. The UHPLC-MS/MS method has several advantages compared to the previous microbial inhibition screening assay, especially for distinguishing individual drugs from a mixture and improving identification of gentamicin in tissue samples. Published by Elsevier B.V.
Evaluation of volatile organic emissions from hazardous waste incinerators.
Sedman, R M; Esparza, J R
1991-01-01
Conventional methods of risk assessment typically employed to evaluate the impact of hazardous waste incinerators on public health must rely on somewhat speculative emissions estimates or on complicated and expensive sampling and analytical methods. The limited amount of toxicological information concerning many of the compounds detected in stack emissions also complicates the evaluation of the public health impacts of these facilities. An alternative approach aimed at evaluating the public health impacts associated with volatile organic stack emissions is presented that relies on a screening criterion to evaluate total stack hydrocarbon emissions. If the concentration of hydrocarbons in ambient air is below the screening criterion, volatile emissions from the incinerator are judged not to pose a significant threat to public health. Both the screening criterion and a conventional method of risk assessment were employed to evaluate the emissions from 20 incinerators. Use of the screening criterion always yielded a substantially greater estimate of risk than that derived by the conventional method. Since the use of the screening criterion always yielded estimates of risk that were greater than that determined by conventional methods and measuring total hydrocarbon emissions is a relatively simple analytical procedure, the use of the screening criterion would appear to facilitate the evaluation of operating hazardous waste incinerators. PMID:1954928
QSPR studies on the photoinduced-fluorescence behaviour of pharmaceuticals and pesticides.
López-Malo, D; Bueso-Bordils, J I; Duart, M J; Alemán-López, P A; Martín-Algarra, R V; Antón-Fos, G M; Lahuerta-Zamora, L; Martínez-Calatayud, J
2017-07-01
Fluorimetric analysis is still a growing line of research in the determination of a wide range of organic compounds, including pharmaceuticals and pesticides, which makes necessary the development of new strategies aimed at improving the performance of fluorescence determinations as well as the sensitivity and, especially, the selectivity of the newly developed analytical methods. In this paper are presented applications of a useful and growing tool suitable for fostering and improving research in the analytical field. Experimental screening, molecular connectivity and discriminant analysis are applied to organic compounds to predict their fluorescent behaviour after their photodegradation by UV irradiation in a continuous flow manifold (multicommutation flow assembly). The screening was based on online fluorimetric measurement and comprised pre-selected compounds with different molecular structures (pharmaceuticals and some pesticides with known 'native' fluorescent behaviour) to study their changes in fluorescent behaviour after UV irradiation. Theoretical predictions agree with the results from the experimental screening and could be used to develop selective analytical methods, as well as helping to reduce the need for expensive, time-consuming and trial-and-error screening procedures.
ERIC Educational Resources Information Center
Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe
2018-01-01
In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…
Stolker, Alida A. M.; Peters, Ruud J. B.; Zuiderent, Richard; DiBussolo, Joseph M.
2010-01-01
There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening method in routine analysis of milk samples. Eight veterinary drugs, belonging to seven different classes were selected for this study. After developing and optimising the method, parameters such as linearity, repeatability, matrix effects and carry-over were studied. The screening method was then tested in the routine analysis of 12 raw milk samples. Even without internal standards, the linearity of the method was found to be good in the concentration range of 50 to 500 µg/L. Regarding repeatability, RSDs below 12% were obtained for all analytes, with only a few exceptions. The limits of detection were between 0.1 and 5.2 µg/L, far below the maximum residue levels for milk set by the EU regulations. While matrix effects—ion suppression or enhancement—are obtained for all the analytes the method has proved to be useful for screening purposes because of its sensitivity, linearity and repeatability. Furthermore, when performing the routine analysis of the raw milk samples, no false positive or negative results were obtained. PMID:20379812
Yao, Yong; Zhang, Chunsun
2016-10-01
A novel screen-printed microfluidic paper-based analytical device with all-carbon electrode-enabled electrochemical assay (SP-ACE-EC-μPAD) has been developed. The fabrication of these devices involved wax screen-printing, which was simple, low-cost and energy-efficient. The working, counter and reference electrodes were screen-printed using carbon ink on the patterned paper devices. Different wax screen-printing processes were examined and optimized, which led to an improved method with a shorter heating time (~5 s) and a lower heating temperature (75 °C). Different printing screens were examined, with a 300-mesh polyester screen yielding the highest quality wax screen-prints. The carbon electrodes were screen-printed on the μPADs and then examined using cyclic voltammetry. The analytical performance of the SP-ACE-EC-μPADs for the detection of glucose and uric acid in standard solutions was investigated. The results were reproducible, with a linear relationship [R(2) = 0.9987 (glucose) or 0.9997 (uric acid)] within the concentration range of interest, and with detection limits as low as 0.35 mM (glucose) and 0.08 mM (uric acid). To determine the clinical utility of the μPADs, chronoamperometry was used to analyze glucose and uric acid in real urine samples using the standard addition method. Our devices were able to detect the analytes of interest in complex real-world biological samples, and have the potential for use in a wide variety of applications.
Stephanson, N N; Signell, P; Helander, A; Beck, O
2017-08-01
The influx of new psychoactive substances (NPS) has created a need for improved methods for drug testing in toxicology laboratories. The aim of this work was to design, validate and apply a multi-analyte liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method for screening of 148 target analytes belonging to the NPS class, plant alkaloids and new psychoactive therapeutic drugs. The analytical method used a fivefold dilution of urine with nine deuterated internal standards and injection of 2 μl. The LC system involved a 2.0 μm 100 × 2.0 mm YMC-UltraHT Hydrosphere-C 18 column and gradient elution with a flow rate of 0.5 ml/min and a total analysis time of 6.0 min. Solvent A consisted of 10 mmol/l ammonium formate and 0.005% formic acid, pH 4.8, and Solvent B was methanol with 10 mmol/l ammonium formate and 0.005% formic acid. The HRMS (Q Exactive, Thermo Scientific) used a heated electrospray interface and was operated in positive mode with 70 000 resolution. The scan range was 100-650 Da, and data for extracted ion chromatograms used ± 10 ppm tolerance. Product ion monitoring was applied for confirmation analysis and for some selected analytes also for screening. Method validation demonstrated limited influence from urine matrix, linear response within the measuring range (typically 0.1-1.0 μg/ml) and acceptable imprecision in quantification (CV <15%). A few analytes were found to be unstable in urine upon storage. The method was successfully applied for routine drug testing of 17 936 unknown samples, of which 2715 (15%) contained 52 of the 148 analytes. It is concluded that the method design based on simple dilution of urine and using LC-HRMS in extracted ion chromatogram mode may offer an analytical system for urine drug testing that fulfils the requirement of a 'black box' solution and can replace immunochemical screening applied on autoanalyzers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Ho, Sirikit; Lukacs, Zoltan; Hoffmann, Georg F; Lindner, Martin; Wetter, Thomas
2007-07-01
In newborn screening with tandem mass spectrometry, multiple intermediary metabolites are quantified in a single analytical run for the diagnosis of fatty-acid oxidation disorders, organic acidurias, and aminoacidurias. Published diagnostic criteria for these disorders normally incorporate a primary metabolic marker combined with secondary markers, often analyte ratios, for which the markers have been chosen to reflect metabolic pathway deviations. We applied a procedure to extract new markers and diagnostic criteria for newborn screening to the data of newborns with confirmed medium-chain acyl-CoA dehydrogenase deficiency (MCADD) and a control group from the newborn screening program, Heidelberg, Germany. We validated the results with external data of the screening center in Hamburg, Germany. We extracted new markers by performing a systematic search for analyte combinations (features) with high discriminatory performance for MCADD. To select feature thresholds, we applied automated procedures to separate controls and cases on the basis of the feature values. Finally, we built classifiers from these new markers to serve as diagnostic criteria in screening for MCADD. On the basis of chi(2) scores, we identified approximately 800 of >628,000 new analyte combinations with superior discriminatory performance compared with the best published combinations. Classifiers built with the new features achieved diagnostic sensitivities and specificities approaching 100%. Feature construction methods provide ways to disclose information hidden in the set of measured analytes. Other diagnostic tasks based on high-dimensional metabolic data might also profit from this approach.
Drug screening in medical examiner casework by high-resolution mass spectrometry (UPLC-MSE-TOF).
Rosano, Thomas G; Wood, Michelle; Ihenetu, Kenneth; Swift, Thomas A
2013-10-01
Postmortem drug findings yield important analytical evidence in medical examiner casework, and chromatography coupled with nominal mass spectrometry (MS) serves as the predominant general unknown screening approach. We report screening by ultra performance liquid chromatography (UPLC) coupled with hybrid quadrupole time-of-flight mass spectrometer (MS(E)-TOF), with comparison to previously validated nominal mass UPLC-MS and UPLC-MS-MS methods. UPLC-MS(E)-TOF screening for over 950 toxicologically relevant drugs and metabolites was performed in a full-spectrum (m/z 50-1,000) mode using an MS(E) acquisition of both molecular and fragment ion data at low (6 eV) and ramped (10-40 eV) collision energies. Mass error averaged 1.27 ppm for a large panel of reference drugs and metabolites. The limit of detection by UPLC-MS(E)-TOF ranges from 0.5 to 100 ng/mL and compares closely with UPLC-MS-MS. The influence of column recovery and matrix effect on the limit of detection was demonstrated with ion suppression by matrix components correlating closely with early and late eluting reference analytes. Drug and metabolite findings by UPLC-MS(E)-TOF were compared with UPLC-MS and UPLC-MS-MS analyses of postmortem blood in 300 medical examiner cases. Positive findings by all methods totaled 1,528, with a detection rate of 57% by UPLC-MS, 72% by UPLC-MS-MS and 80% by combined UPLC-MS and UPLC-MS-MS screening. Compared with nominal mass screening methods, UPLC-MS(E)-TOF screening resulted in a 99% detection rate and, in addition, offered the potential for the detection of nontargeted analytes via high-resolution acquisition of molecular and fragment ion data.
Screening of 23 β-lactams in foodstuffs by LC-MS/MS using an alkaline QuEChERS-like extraction.
Bessaire, Thomas; Mujahid, Claudia; Beck, Andrea; Tarres, Adrienne; Savoy, Marie-Claude; Woo, Pei-Mun; Mottier, Pascal; Desmarchelier, Aurélien
2018-04-01
A fast and robust high performance LC-MS/MS screening method was developed for the analysis of β-lactam antibiotics in foods of animal origin: eggs, raw milk, processed dairy ingredients, infant formula, and meat- and fish-based products including baby foods. QuEChERS extraction with some adaptations enabled 23 drugs to be simultaneously monitored. Screening target concentrations were set at levels adequate to ensure compliance with current European, Chinese, US and Canadian regulations. The method was fully validated according to the European Community Reference Laboratories Residues Guidelines using 93 food samples of different composition. False-negative and false-positive rates were below 5% for all analytes. The method is adequate for use in high-routine laboratories. A 1-year study was additionally conducted to assess the stability of the 23 analytes in the working standard solution.
Pasin, Daniel; Cawley, Adam; Bidny, Sergei; Fu, Shanlin
2017-10-01
The proliferation of new psychoactive substances (NPS) in recent years has resulted in the development of numerous analytical methods for the detection and identification of known and unknown NPS derivatives. High-resolution mass spectrometry (HRMS) has been identified as the method of choice for broad screening of NPS in a wide range of analytical contexts because of its ability to measure accurate masses using data-independent acquisition (DIA) techniques. Additionally, it has shown promise for non-targeted screening strategies that have been developed in order to detect and identify novel analogues without the need for certified reference materials (CRMs) or comprehensive mass spectral libraries. This paper reviews the applications of HRMS for the analysis of NPS in forensic drug chemistry and analytical toxicology. It provides an overview of the sample preparation procedures in addition to data acquisition, instrumental analysis, and data processing techniques. Furthermore, it gives an overview of the current state of non-targeted screening strategies with discussion on future directions and perspectives of this technique. Graphical Abstract Missing the bullseye - a graphical respresentation of non-targeted screening. Image courtesy of Christian Alonzo.
Bidny, Sergei; Gago, Kim; Chung, Phuong; Albertyn, Desdemona; Pasin, Daniel
2017-04-01
An analytical method using ultra performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry (QTOF-MS) was developed and validated for the targeted toxicological screening and quantification of commonly used pharmaceuticals and drugs of abuse in postmortem blood using 100 µL sample. It screens for more than 185 drugs and metabolites and quantifies more than 90 drugs. The selected compounds include classes of pharmaceuticals and drugs of abuse such as: antidepressants, antipsychotics, analgesics (including narcotic analgesics), anti-inflammatory drugs, benzodiazepines, beta-blockers, amphetamines, new psychoactive substances (NPS), cocaine and metabolites. Compounds were extracted into acetonitrile using a salting-out assisted liquid-liquid extraction (SALLE) procedure. The extracts were analyzed using a Waters ACQUITY UPLC coupled with a XEVO QTOF mass spectrometer. Separation of the analytes was achieved by gradient elution using Waters ACQUITY HSS C18 column (2.1 mm x 150 mm, 1.8 μm). The mass spectrometer was operated in both positive and negative electrospray ionization modes. The high-resolution mass spectrometry (HRMS) data was acquired using a patented Waters MSE acquisition mode which collected low and high energy spectra alternatively during the same acquisition. Positive identification of target analytes was based on accurate mass measurements of the molecular ion, product ion, peak area ratio and retention times. Calibration curves were linear over the concentration range 0.05-2 mg/L for basic and neutral analytes and 0.1-6 mg/L for acidic analytes with the correlation coefficients (r2) > 0.96 for most analytes. The limits of detection (LOD) were between 0.001-0.05 mg/L for all analytes. Good recoveries were achieved ranging from 80% to 100% for most analytes using the SALLE method. The method was validated for sensitivity, selectivity, accuracy, precision, stability, carryover and matrix effects. The developed method was tested on a number of authentic forensic samples producing consistent results that correlated with results obtained from other validated methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Diving deeper into Zebrafish development of social behavior: analyzing high resolution data.
Buske, Christine; Gerlai, Robert
2014-08-30
Vertebrate model organisms have been utilized in high throughput screening but only with substantial cost and human capital investment. The zebrafish is a vertebrate model species that is a promising and cost effective candidate for efficient high throughput screening. Larval zebrafish have already been successfully employed in this regard (Lessman, 2011), but adult zebrafish also show great promise. High throughput screening requires the use of a large number of subjects and collection of substantial amount of data. Collection of data is only one of the demanding aspects of screening. However, in most screening approaches that involve behavioral data the main bottleneck that slows throughput is the time consuming aspect of analysis of the collected data. Some automated analytical tools do exist, but often they only work for one subject at a time, eliminating the possibility of fully utilizing zebrafish as a screening tool. This is a particularly important limitation for such complex phenotypes as social behavior. Testing multiple fish at a time can reveal complex social interactions but it may also allow the identification of outliers from a group of mutagenized or pharmacologically treated fish. Here, we describe a novel method using a custom software tool developed within our laboratory, which enables tracking multiple fish, in combination with a sophisticated analytical approach for summarizing and analyzing high resolution behavioral data. This paper focuses on the latter, the analytic tool, which we have developed using the R programming language and environment for statistical computing. We argue that combining sophisticated data collection methods with appropriate analytical tools will propel zebrafish into the future of neurobehavioral genetic research. Copyright © 2014. Published by Elsevier B.V.
Woods, Lucy A; Dolezal, Olan; Ren, Bin; Ryan, John H; Peat, Thomas S; Poulsen, Sally-Ann
2016-03-10
Fragment-based drug discovery (FBDD) is contingent on the development of analytical methods to identify weak protein-fragment noncovalent interactions. Herein we have combined an underutilized fragment screening method, native state mass spectrometry, together with two proven and popular fragment screening methods, surface plasmon resonance and X-ray crystallography, in a fragment screening campaign against human carbonic anhydrase II (CA II). In an initial fragment screen against a 720-member fragment library (the "CSIRO Fragment Library") seven CA II binding fragments, including a selection of nonclassical CA II binding chemotypes, were identified. A further 70 compounds that comprised the initial hit chemotypes were subsequently sourced from the full CSIRO compound collection and screened. The fragment results were extremely well correlated across the three methods. Our findings demonstrate that there is a tremendous opportunity to apply native state mass spectrometry as a complementary fragment screening method to accelerate drug discovery.
Andrade, Ana Flávia B; Mamo, Samuel Kasahun; Gonzalez-Rodriguez, Jose
2017-02-07
The NBOMe derivatives are phenethylamines derived from the 2C class of hallucinogens. Only a few human pharmacologic studies have been conducted on these drugs, and several cases of intoxication and deaths have been reported. Presently, NBOMe are not a part of the routine drugs-of-abuse screening procedure for many police forces, and there are no rapid immunoassay screening tests that can detect the presence of those compounds. In this Article, the voltammetric behavior of 25B NBOMe and 25I NBOMe were investigated and their electroanalytical characteristics determined for the first time. A novel, fast, and sensitive screening method for the identification of the two most common NBOMes (25B-NBOMe and 25I-NBOMe) in real samples is reported. The method uses the electrochemical oxidation of these molecules to produce an analytical signal that can be related to the NBOMe concentration with an average lower limit of quantitation of 0.01 mg/mL for both of them. The method is selective enough to identify the two compounds individually, even given the great similarity in their structure.
Sun, Meng; Ma, Wei-na; Guo, Ying; Hu, Zhi-gang; He, Lang-chong
2013-07-01
The epidermal growth factor receptors (EGFRs) are significant targets for screening active compounds. In this work, an analytical method was established for rapid screening, separation, and identification of EGFRs antagonists from Curcuma longa. Human embryonic kidney 293 cells with a steadily high expression of EGFRs were used to prepare the cell membrane stationary phase in a cell membrane chromatography model for screening active compounds. Separation and identification of the retention chromatographic peaks was achieved by HPLC-MS. The active sites, docking extents and inhibitory effects of the active compounds were also demonstrated. The screening result found that ar-turmerone, curcumin, demethoxycurcumin, and bisdemethoxycurcumin from Curcuma longa could be active components in a similar manner to gefitinib. Biological trials showed that all of four compounds can inhibit EGFRs protein secretion and cell growth in a dose-dependent manner, and downregulate the phosphorylation of EGFRs. This analytical method demonstrated fast and effective characteristics for screening, separation and identification of the active compounds from a complex system and should be useful for drug discovery with natural medicinal herbs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A calibration method for fringe reflection technique based on the analytical phase-slope description
NASA Astrophysics Data System (ADS)
Wu, Yuxiang; Yue, Huimin; Pan, Zhipeng; Liu, Yong
2018-05-01
The fringe reflection technique (FRT) has been one of the most popular methods to measure the shape of specular surface these years. The existing system calibration methods of FRT usually contain two parts, which are camera calibration and geometric calibration. In geometric calibration, the liquid crystal display (LCD) screen position calibration is one of the most difficult steps among all the calibration procedures, and its accuracy is affected by the factors such as the imaging aberration, the plane mirror flatness, and LCD screen pixel size accuracy. In this paper, based on the deduction of FRT analytical phase-slope description, we present a novel calibration method with no requirement to calibrate the position of LCD screen. On the other hand, the system can be arbitrarily arranged, and the imaging system can either be telecentric or non-telecentric. In our experiment of measuring the 5000mm radius sphere mirror, the proposed calibration method achieves 2.5 times smaller measurement error than the geometric calibration method. In the wafer surface measuring experiment, the measurement result with the proposed calibration method is closer to the interferometer result than the geometric calibration method.
Stabilization of glucose-oxidase in the graphene paste for screen-printed glucose biosensor
NASA Astrophysics Data System (ADS)
Pepłowski, Andrzej; Janczak, Daniel; Jakubowska, Małgorzata
2015-09-01
Various methods and materials for enzyme stabilization within screen-printed graphene sensor were analyzed. Main goal was to develop technology allowing immediate printing of the biosensors in single printing process. Factors being considered were: toxicity of the materials used, ability of the material to be screen-printed (squeezed through the printing mesh) and temperatures required in the fabrication process. Performance of the examined sensors was measured using chemical amperometry method, then appropriate analysis of the measurements was conducted. The analysis results were then compared with the medical requirements. Parameters calculated were: correlation coefficient between concentration of the analyte and the measured electrical current (0.986) and variation coefficient for the particular concentrations of the analyte used as the calibration points. Variation of the measured values was significant only in ranges close to 0, decreasing for the concentrations of clinical importance. These outcomes justify further development of the graphene-based biosensors fabricated through printing techniques.
Alternative Approaches for Screening Contaminated Sediments and Soils for PCDD/PCDF
Generating analytical data for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) using the traditional high resolution mass spectrometry (HRMS) analysis method, EPA Method 1613B, is time-consuming and expensive. Consequently, alternative methods to ...
Multiplex screening of persistent organic pollutants in fish using spectrally encoded microspheres
USDA-ARS?s Scientific Manuscript database
Persistent organic pollutants (POPs) are food contaminants of global public health concern and known to be carcinogenic and endocrine disruptors. Their monitoring is essential and an easy-to-use, rapid and affordable multi-analyte screening method with simplified sample preparation can be a valuable...
USDA-ARS?s Scientific Manuscript database
A rapid luminescence method was developed to screen residues of enrofloxacin (ENRO) and its metabolite, ciprofloxacin (CIPRO), in swine liver. Target analytes were extracted in acetonitrile-2.5% trifluoroacetic acid-NaCl, cleaned up by dispersive liquid-liquid microextraction (DLLME), and finally de...
Gosselin, Robert C; Adcock, Dorothy M; Bates, Shannon M; Douxfils, Jonathan; Favaloro, Emmanuel J; Gouin-Thibault, Isabelle; Guillermo, Cecilia; Kawai, Yohko; Lindhoff-Last, Edelgard; Kitchen, Steve
2018-03-01
This guidance document was prepared on behalf of the International Council for Standardization in Haematology (ICSH) for providing haemostasis-related guidance documents for clinical laboratories. This inaugural coagulation ICSH document was developed by an ad hoc committee, comprised of international clinical and laboratory direct acting oral anticoagulant (DOAC) experts. The committee developed consensus recommendations for laboratory measurement of DOACs (dabigatran, rivaroxaban, apixaban and edoxaban), which would be germane for laboratories assessing DOAC anticoagulation. This guidance document addresses all phases of laboratory DOAC measurements, including pre-analytical (e.g. preferred time sample collection, preferred sample type, sample stability), analytical (gold standard method, screening and quantifying methods) and post analytical (e.g. reporting units, quality assurance). The committee addressed the use and limitations of screening tests such as prothrombin time, activated partial thromboplastin time as well as viscoelastic measurements of clotting blood and point of care methods. Additionally, the committee provided recommendations for the proper validation or verification of performance of laboratory assays prior to implementation for clinical use, and external quality assurance to provide continuous assessment of testing and reporting method. Schattauer GmbH Stuttgart.
Overview of mycotoxin methods, present status and future needs.
Gilbert, J
1999-01-01
This article reviews current requirements for the analysis for mycotoxins in foods and identifies legislative as well as other factors that are driving development and validation of new methods. New regulatory limits for mycotoxins and analytical quality assurance requirements for laboratories to only use validated methods are seen as major factors driving developments. Three major classes of methods are identified which serve different purposes and can be categorized as screening, official and research. In each case the present status and future needs are assessed. In addition to an overview of trends in analytical methods, some other areas of analytical quality assurance such as participation in proficiency testing and reference materials are identified.
Bakken, Gregory A; Bell, Andrew S; Boehm, Markus; Everett, Jeremy R; Gonzales, Rosalia; Hepworth, David; Klug-McLeod, Jacquelyn L; Lanfear, Jeremy; Loesel, Jens; Mathias, John; Wood, Terence P
2012-11-26
High Throughput Screening (HTS) is a successful strategy for finding hits and leads that have the opportunity to be converted into drugs. In this paper we highlight novel computational methods used to select compounds to build a new screening file at Pfizer and the analytical methods we used to assess their quality. We also introduce the novel concept of molecular redundancy to help decide on the density of compounds required in any region of chemical space in order to be confident of running successful HTS campaigns.
Chau, Hong Thi Cam; Kadokami, Kiwao; Ifuku, Tomomi; Yoshida, Yusuke
2017-12-01
A comprehensive screening method for 311 organic compounds with a wide range of physicochemical properties (log Pow -2.2-8.53) in water samples was developed by combining solid-phase extraction with liquid chromatography-high-resolution time-of-flight mass spectrometry. Method optimization using 128 pesticides revealed that tandem extraction with styrene-divinylbenzene polymer and activated carbon solid-phase extraction cartridges at pH 7.0 was optimal. The developed screening method was able to extract 190 model compounds with average recovery of 80.8% and average relative standard deviations (RSD) of 13.5% from spiked reagent water at 0.20 μg L -1 , and 87.1% recovery and 10.8% RSD at 0.05 μg L -1 . Spike-recovery testing (0.20 μg L -1 ) using real sewage treatment plant effluents resulted in an average recovery and average RSD of 190 model compounds of 77.4 and 13.1%, respectively. The method was applied to the influent and effluent of five sewage treatment plants in Kitakyushu, Japan, with 29 out of 311 analytes being observed at least once. The results showed that this method can screen for a large number of chemicals with a wide range of physicochemical properties quickly and at low operational cost, something that is difficult to achieve using conventional analytical methods. This method will find utility in target screening of hazardous chemicals with a high risk in environmental waters, and for confirming the safety of water after environmental incidents.
NASA Astrophysics Data System (ADS)
Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho
2013-10-01
Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0-10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700-5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods.
Shao, Jingyuan; Cao, Wen; Qu, Haibin; Pan, Jianyang; Gong, Xingchu
2018-01-01
The aim of this study was to present a novel analytical quality by design (AQbD) approach for developing an HPLC method to analyze herbal extracts. In this approach, critical method attributes (CMAs) and critical method parameters (CMPs) of the analytical method were determined using the same data collected from screening experiments. The HPLC-ELSD method for separation and quantification of sugars in Codonopsis Radix extract (CRE) samples and Astragali Radix extract (ARE) samples was developed as an example method with a novel AQbD approach. Potential CMAs and potential CMPs were found with Analytical Target Profile. After the screening experiments, the retention time of the D-glucose peak of CRE samples, the signal-to-noise ratio of the D-glucose peak of CRE samples, and retention time of the sucrose peak in ARE samples were considered CMAs. The initial and final composition of the mobile phase, flow rate, and column temperature were found to be CMPs using a standard partial regression coefficient method. The probability-based design space was calculated using a Monte-Carlo simulation method and verified by experiments. The optimized method was validated to be accurate and precise, and then it was applied in the analysis of CRE and ARE samples. The present AQbD approach is efficient and suitable for analysis objects with complex compositions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Safari, L., E-mail: laleh.safari@ist.ac.at; Department of Physics, University of Oulu, Box 3000, FI-90014 Oulu; Santos, J. P.
Atomic form factors are widely used for the characterization of targets and specimens, from crystallography to biology. By using recent mathematical results, here we derive an analytical expression for the atomic form factor within the independent particle model constructed from nonrelativistic screened hydrogenic wave functions. The range of validity of this analytical expression is checked by comparing the analytically obtained form factors with the ones obtained within the Hartee-Fock method. As an example, we apply our analytical expression for the atomic form factor to evaluate the differential cross section for Rayleigh scattering off neutral atoms.
Tian, Yuzhen; Guo, Jin; Wang, Rui; Wang, Tingfeng
2011-09-12
In order to research the statistical properties of Gaussian beam propagation through an arbitrary thickness random phase screen for adaptive optics and laser communication application in the laboratory, we establish mathematic models of statistical quantities, which are based on the Rytov method and the thin phase screen model, involved in the propagation process. And the analytic results are developed for an arbitrary thickness phase screen based on the Kolmogorov power spectrum. The comparison between the arbitrary thickness phase screen and the thin phase screen shows that it is more suitable for our results to describe the generalized case, especially the scintillation index.
Biomass Characterization | Bioenergy | NREL
analytical methods for biomass characterization available for downloading. View the Biomass Compositional Methods Molecular Beam Mass Spectrometry Photo of a man in front of multiple computer screens that present Characterization of Biomass We develop new methods and tools to understand the chemical composition of raw biomass
"Dip-and-read" paper-based analytical devices using distance-based detection with color screening.
Yamada, Kentaro; Citterio, Daniel; Henry, Charles S
2018-05-15
An improved paper-based analytical device (PAD) using color screening to enhance device performance is described. Current detection methods for PADs relying on the distance-based signalling motif can be slow due to the assay time being limited by capillary flow rates that wick fluid through the detection zone. For traditional distance-based detection motifs, analysis can take up to 45 min for a channel length of 5 cm. By using a color screening method, quantification with a distance-based PAD can be achieved in minutes through a "dip-and-read" approach. A colorimetric indicator line deposited onto a paper substrate using inkjet-printing undergoes a concentration-dependent colorimetric response for a given analyte. This color intensity-based response has been converted to a distance-based signal by overlaying a color filter with a continuous color intensity gradient matching the color of the developed indicator line. As a proof-of-concept, Ni quantification in welding fume was performed as a model assay. The results of multiple independent user testing gave mean absolute percentage error and average relative standard deviations of 10.5% and 11.2% respectively, which were an improvement over analysis based on simple visual color comparison with a read guide (12.2%, 14.9%). In addition to the analytical performance comparison, an interference study and a shelf life investigation were performed to further demonstrate practical utility. The developed system demonstrates an alternative detection approach for distance-based PADs enabling fast (∼10 min), quantitative, and straightforward assays.
Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes
Titoiu, Ana Maria; Marty, Jean-Louis
2018-01-01
This review provides a brief overview of the fabrication and properties of screen-printed electrodes and details the different opportunities to apply them for the detection of antibiotics, detection of bacteria and antibiotic susceptibility. Among the alternative approaches to costly chromatographic or ELISA methods for antibiotics detection and to lengthy culture methods for bacteria detection, electrochemical biosensors based on screen-printed electrodes present some distinctive advantages. Chemical and (bio)sensors for the detection of antibiotics and assays coupling detection with screen-printed electrodes with immunomagnetic separation are described. With regards to detection of bacteria, the emphasis is placed on applications targeting viable bacterial cells. While the electrochemical sensors and biosensors face many challenges before replacing standard analysis methods, the potential of screen-printed electrodes is increasingly exploited and more applications are anticipated to advance towards commercial analytical tools. PMID:29562637
EVALUATION OF POHC AND PIC SCREENING METHODS
A recurring theme in environmental work is the need to characterize emissions to the maximum extent at the minimum cost. Unfortunately, many projects have been carried out In the past with little thought or planning concerning the optimum application of analytical methods availab...
Wang, Jian; Leung, Daniel
2012-08-01
This paper discusses the analytical challenges to develop a generic extraction procedure to analyze or screen multi-class veterinary drugs in milk and honey using ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC QqTOF MS). The veterinary drugs in this study included aminoglycosides, endectocides, fluoroquinolones, ionophores, β-lactams or penicillins, macrolides, NSAIDs, phenicols, sulfonamides and tetracyclines. Veterinary drugs were extracted using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) method, which entailed the use of acetonitrile containing 1% acetic acid, sodium acetate, ethylenediaminetetra acetic acid disodium (EDTA) and magnesium sulfate, and no clean-up was performed. Chromatographic separation was achieved on a reversed-phase Acquity UPLC BEH C(18) , 100 × 2.1 mm, 1.7 µm column with 0.1% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. Due to poor chromatographic retention, aminoglycosides were first dropped from the list, and because of poor extractability, β-lactams and tetracyclines were also excluded from the method. The method was able to quantify 31 or screen up to 54 drugs (unbound) in honey, and to quantify 34 or screen up to 59 drugs in milk. UHPLC QqTOF data were acquired in TOF MS full-scan mode that allowed both quantification and confirmation of veterinary drugs and identification of their degradation products in samples. The method could achieve detection limits as low as 1 µg/kg with analytical range from 1 to 100 µg/kg. The developed method was intended to be used for screening of as many analytes as possible in one single analysis, or unequivocal confirmation of positive findings and degradation product identification based on accurate mass measurement and isotopic patterns. © Her Majesty the Queen in Right of Canada 2012. Reproduced with the permission of the Minister of Agriculture.
Pedersen, Anders Just; Dalsgaard, Petur Weihe; Rode, Andrej Jaroslav; Rasmussen, Brian Schou; Müller, Irene Breum; Johansen, Sys Stybe; Linnet, Kristian
2013-07-01
A broad forensic screening method for 256 analytes in whole blood based on a fully automated SPE robotic extraction and ultra-high-performance liquid chromatography (UHPLC) with TOF-MS with data-independent acquisition has been developed. The limit of identification was evaluated for all 256 compounds and 95 of these compounds were validated with regard to matrix effects, extraction recovery, and process efficiency. The limit of identification ranged from 0.001 to 0.1 mg/kg, and the process efficiency exceeded 50% for 73 of the 95 analytes. As an example of application, 1335 forensic traffic cases were analyzed with the presented screening method. Of these, 992 cases (74%) were positive for one or more traffic-relevant drugs above the Danish legal limits. Commonly abused drugs such as amphetamine, cocaine, and frequent types of benzodiazepines were the major findings. Nineteen less frequently encountered drugs were detected e.g. buprenorphine, butylone, cathine, fentanyl, lysergic acid diethylamide, m-chlorophenylpiperazine, 3,4-methylenedioxypyrovalerone, mephedrone, 4-methylamphetamine, p-fluoroamphetamine, and p-methoxy-N-methylamphetamine. In conclusion, using UHPLC-TOF-MS screening with data-independent acquisition resulted in the detection of common drugs of abuse as well as new designer drugs and more rarely occurring drugs. Thus, TOF-MS screening of blood samples constitutes a practical way for screening traffic cases, with the exception of δ-9-tetrahydrocannabinol, which should be handled in a separate method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Environmental immunochemical methods are responding to the changing needs of regulatory and monitoring programs and are meeting new analytical challenges as they arise. Immunoassays are being developed for screening multiple organophosphorous (OP) pesticides (0,0-diethyl thionate...
A set of three complementary analytical methods were developed specifically for exhaled breath as collected in evacuated stainless steel canisters using gas chromatography - mass spectrometry detection. The first is a screening method to quantify the carbon dioxide component (gen...
Immunoehemical methods are responding to the changing needs of regulatory and monitoring programs and are meeting new analytical challenges as they arise. Recent advances in environmental immunoehemistry have expanded the role of immunoassays from field screening methods to hig...
Benn, Peter A; Makowski, Gregory S; Egan, James F X; Wright, Dave
2006-11-01
Analytical error affects 2nd-trimester maternal serum screening for Down syndrome risk estimation. We analyzed the between-laboratory reproducibility of risk estimates from 2 laboratories. Laboratory 1 used Bayer ACS180 immunoassays for alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG), Diagnostic Systems Laboratories (DSL) RIA for unconjugated estriol (uE3), and DSL enzyme immunoassay for inhibin-A (INH-A). Laboratory 2 used Beckman immunoassays for AFP, hCG, and uE3, and DSL enzyme immunoassay for INH-A. Analyte medians were separately established for each laboratory. We used the same computational algorithm for all risk calculations, and we used Monte Carlo methods for computer modeling. For 462 samples tested, risk figures from the 2 laboratories differed >2-fold for 44.7%, >5-fold for 7.1%, and >10-fold for 1.7%. Between-laboratory differences in analytes were greatest for uE3 and INH-A. The screen-positive rates were 9.3% for laboratory 1 and 11.5% for laboratory 2, with a significant difference in the patients identified as screen-positive vs screen-negative (McNemar test, P<0.001). Computer modeling confirmed the large between-laboratory risk differences. Differences in performance of assays and laboratory procedures can have a large effect on patient-specific risks. Screening laboratories should minimize test imprecision and ensure that each assay performs in a manner similar to that assumed in the risk computational algorithm.
Screening attenuation of coaxial cables determined in GTEM-cells
NASA Astrophysics Data System (ADS)
Knobloch, A.; Garbe, H.
2004-05-01
This paper describes the determination of the screening attenuation with a GTEM cell. An analytical part gives the link between the voltage at the cell port and the total radiated power. The next section investigates the optimal cable setup in the cell. With a measurement of the common mode current on the cable and a simulation of the radiation resistance the loop antenna characteristic of the cable setup could be verified. It is shown that the use of ferrit cores decrease the difference between the maximum and the minimum screening attenuation. The determination of great screening attenuation could be improved with the use of N-type measurement cables. A comparison between this GTEM cell method and the standard methods shows a good agreement.
Advances in aptamer screening and small molecule aptasensors.
Kim, Yeon Seok; Gu, Man Bock
2014-01-01
It has been 20 years since aptamer and SELEX (systematic evolution of ligands by exponential enrichment) were described independently by Andrew Ellington and Larry Gold. Based on the great advantages of aptamers, there have been numerous isolated aptamers for various targets that have actively been applied as therapeutic and analytical tools. Over 2,000 papers related to aptamers or SELEX have been published, attesting to their wide usefulness and the applicability of aptamers. SELEX methods have been modified or re-created over the years to enable aptamer isolation with higher affinity and selectivity in more labor- and time-efficient manners, including automation. Initially, most of the studies about aptamers have focused on the protein targets, which have physiological functions in the body, and their applications as therapeutic agents or receptors for diagnostics. However, aptamers for small molecules such as organic or inorganic compounds, drugs, antibiotics, or metabolites have not been studied sufficiently, despite the ever-increasing need for rapid and simple analytical methods for various chemical targets in the fields of medical diagnostics, environmental monitoring, food safety, and national defense against targets including chemical warfare. This review focuses on not only recent advances in aptamer screening methods but also its analytical application for small molecules.
Surface Plasmon Resonance: New Biointerface Designs and High-Throughput Affinity Screening
NASA Astrophysics Data System (ADS)
Linman, Matthew J.; Cheng, Quan Jason
Surface plasmon resonance (SPR) is a surface optical technique that measures minute changes in refractive index at a metal-coated surface. It has become increasingly popular in the study of biological and chemical analytes because of its label-free measurement feature. In addition, SPR allows for both quantitative and qualitative assessment of binding interactions in real time, making it ideally suited for probing weak interactions that are often difficult to study with other methods. This chapter presents the biosensor development in the last 3 years or so utilizing SPR as the principal analytical technique, along with a concise background of the technique itself. While SPR has demonstrated many advantages, it is a nonselective method and so, building reproducible and functional interfaces is vital to sensing applications. This chapter, therefore, focuses mainly on unique surface chemistries and assay approaches to examine biological interactions with SPR. In addition, SPR imaging for high-throughput screening based on microarrays and novel hyphenated techniques involving the coupling of SPR to other analytical methods is discussed. The chapter concludes with a commentary on the current state of SPR biosensing technology and the general direction of future biosensor research.
Nie, Honggang; Li, Xianjiang; Hua, Zhendong; Pan, Wei; Bai, Yanping; Fu, Xiaofang
2016-08-01
With the amounts and types of new psychoactive substances (NPSs) increasing rapidly in recent years, an excellent high-throughput method for the analysis of these compounds is urgently needed. In this article, a rapid screening method and a quantitative analysis method for 11 NPSs are described and compared, respectively. A simple direct analysis in real time mass spectrometry (DART-MS) method was developed for the analysis of 11 NPSs including three categories of these substances present on the global market such as four cathinones, one phenylethylamine, and six synthetic cannabinoids. In order to analyze these compounds quantitatively with better accuracy and sensitivity, another rapid analytical method with a low limit of detection (LOD) was also developed using liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry (LC/QTOFMS). The 11 NPSs could be determined within 0.5 min by DART-MS. Furthermore, they could also be separated and determined within 5 min by the LC/QTOFMS method. The two methods both showed good linearity with correlation coefficients (r(2) ) higher than 0.99. The LODs for all these target NPSs by DART-MS and LC/QTOFMS ranged from 5 to 40 ng mL(-1) and 0.1 to 1 ng mL(-1) , respectively. Confiscated samples, named as "music vanilla" and "bath salt", and 11 spiked samples were firstly screened by DART-MS and then determined by LC/QTOFMS. The identification of NPSs in confiscated materials was successfully achieved, and the proposed analytical methodology could offer rapid screening and accurate analysis results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Arribas, Alberto Sánchez; Bermejo, Esperanza; Zapardiel, Antonio; Téllez, Helena; Rodríguez-Flores, Juana; Zougagh, Mohammed; Ríos, Angel; Chicharro, Manuel
2009-02-01
A simple analytical scheme for the screening and quantification of zearalenone and its metabolites, alpha-zearalenol and beta-zearalenol, is reported. Extracts from maize flour samples were collected by supercritical fluid extraction and afterwards, they were analyzed by CE with amperometric detection. This scheme allowed a rapid and reliable identification of contaminated flour samples according to the reference value established for zearalenone by directive 2005/38/EC (200 microg/kg). The sample screening method was carried out by CZE using 25 mM borate separation buffer at pH 9.2 and 25.0 kV as separation voltage, monitoring the amperometric signal at +700 mV with a carbon paste electrode. In this way, total amount of mycotoxins was determined and samples were processed in 4 min with a detection limit of 12 microg/L, enough to discriminate between positive (more than 200 microg/L total mycotoxins) and negative samples (less than 200 microg/L total mycotoxins). Positive samples were then subjected to CZE separation and quantification of each analyte was done with 50 mM borate running buffer modified with 30% methanol at pH 9.7 and 17.5 kV as separation voltage. Under these conditions, separation was achieved in 15 min with detection limits from 20 to 35 microg/L for each analyte.
Huppertz, Laura M; Kneisel, Stefan; Auwärter, Volker; Kempf, Jürgen
2014-02-01
Considering the vast variety of synthetic cannabinoids and herbal mixtures - commonly known as 'Spice' or 'K2' - on the market and the resulting increase of severe intoxications related to their consumption, there is a need in clinical and forensic toxicology for comprehensive up-to-date screening methods. The focus of this project aimed at developing and implementing an automated screening procedure for the detection of synthetic cannabinoids in serum using a liquid chromatography-ion trap-MS (LC-MS(n)) system and a spectra library-based approach, currently including 46 synthetic cannabinoids and 8 isotope labelled analogues. In the process of method development, a high-temperature ESI source (IonBooster(TM), Bruker Daltonik) and its effects on the ionization efficiency of the investigated synthetic cannabinoids were evaluated and compared to a conventional ESI source. Despite their structural diversity, all investigated synthetic cannabinoids benefitted from high-temperature ionization by showing remarkably higher MS intensities compared to conventional ESI. The employed search algorithm matches retention time, MS and MS(2)/MS(3) spectra. With the utilization of the ionBooster source, limits for the automated detection comparable to cut-off values of routine MRM methods were achieved for the majority of analytes. Even compounds not identified when using a conventional ESI source were detected using the ionBooster-source. LODs in serum range from 0.1 ng/ml to 0.5 ng/ml. The use of parent compounds as analytical targets offers the possibility of instantly adding new emerging compounds to the library and immediately applying the updated method to serum samples, allowing the rapid adaptation of the screening method to ongoing forensic or clinical requirements. The presented approach can also be applied to other specimens, such as oral fluid or hair, and herbal mixtures and was successfully applied to authentic serum samples. Quantitative MRM results of samples with analyte concentrations above the determined LOD were confirmed as positive findings by the presented method. Copyright © 2014 John Wiley & Sons, Ltd.
1982-01-01
bromide is listed as a positive interference. Nitric oxide and nitrogen dioxide can be detected by using the Draeger nitrous fumes detector tube. A... fumes exhibit a delay from the time of exposure to the onset of symptoms. This time delay would not be conducive for a rapid field screening test. It...Dangerous when strongly heated, emits highly toxic fumes . THRESHOLD LIMIT VALUE: No information available PHYSIOLOGICAL EFFECTS: A. Intensely irritating to
Rieger, Toni; Kerber, Romy; El Halas, Hussein; Pallasch, Elisa; Duraffour, Sophie; Günther, Stephan; Ölschläger, Stephan
2016-01-01
Background. Diagnosis of Ebola virus (EBOV) disease (EVD) requires laboratory testing. Methods. The RealStar Filovirus Screen reverse transcription–polymerase chain reaction (RT-PCR) kit and the derived RealStar Zaire Ebolavirus RT-PCR kit were validated using in vitro transcripts, supernatant of infected cell cultures, and clinical specimens from patients with EVD. Results. The Filovirus Screen kit detected EBOV, Sudan virus, Taï Forest virus, Bundibugyo virus, Reston virus, and Marburg virus and differentiated between the genera Ebolavirus and Marburgvirus. The amount of filovirus RNA that could be detected with a probability of 95% ranged from 11 to 67 RNA copies/reaction on a LightCycler 480 II. The Zaire Ebolavirus kit is based on the Filovirus Screen kit but was optimized for detection of EBOV. It has an improved signal-to-noise ratio at low EBOV RNA concentrations and is somewhat more sensitive than the Filovirus kit. Both kits show significantly lower analytical sensitivity on a SmartCycler II. Clinical evaluation revealed that the SmartCycler II, compared with other real-time PCR platforms, decreases the clinical sensitivity of the Filovirus Screen kit to diagnose EVD at an early stage. Conclusions. The Filovirus Screen kit detects all human-pathogenic filoviruses with good analytical sensitivity if performed on an appropriate real-time PCR platform. High analytical sensitivity is important for early diagnosis of EVD. PMID:27549586
Fast mass spectrometry-based enantiomeric excess determination of proteinogenic amino acids.
Fleischer, Heidi; Thurow, Kerstin
2013-03-01
A rapid determination of the enantiomeric excess of proteinogenic amino acids is of great importance in various fields of chemical and biologic research and industries. Owing to their different biologic effects, enantiomers are interesting research subjects in drug development for the design of new and more efficient pharmaceuticals. Usually, the enantiomeric composition of amino acids is determined by conventional analytical methods such as liquid or gas chromatography or capillary electrophoresis. These analytical techniques do not fulfill the requirements of high-throughput screening due to their relative long analysis times. The method presented allows a fast analysis of chiral amino acids without previous time consuming chromatographic separation. The analytical measurements base on parallel kinetic resolution with pseudoenantiomeric mass tagged auxiliaries and were carried out by mass spectrometry with electrospray ionization. All 19 chiral proteinogenic amino acids were tested and Pro, Ser, Trp, His, and Glu were selected as model substrates for verification measurements. The enantiomeric excesses of amino acids with non-polar and aliphatic side chains as well as Trp and Phe (aromatic side chains) were determined with maximum deviations of the expected value less than or equal to 10ee%. Ser, Cys, His, Glu, and Asp were determined with deviations lower or equal to 14ee% and the enantiomeric excess of Tyr were calculated with 17ee% deviation. The total screening process is fully automated from the sample pretreatment to the data processing. The method presented enables fast measurement times about 1.38 min per sample and is applicable in the scope of high-throughput screenings.
BIOLOGICALLY-BASED RAPID SCREENING METHODS FOR DIOXINS IN THE UNITED STATES
Because of the extensive cost, in personnel, time, equipment, and money to measure dioxin-like chemicals analytically, alternative technologies have been developed to measure the integrated sum of the activity of the dioxin-like chemicals.
Otero-Fernández, Mara; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2013-06-19
A micro-analytical method based on spotting urine samples (20μL) onto blood/urine spot collection cards followed by air-drying and extraction (dried urine spot, DUS) was developed and validated for the screening/confirmation assay of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE). Acetonitrile (3 mL) was found to be a useful solvent for target extraction from DUSs under an orbital-horizontal stirring at 180 rpm for 10 min. Determinations were performed by direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) under positive electrospray ionization conditions, and by using multiple reaction monitoring (MRM) with one precursor ion/product ion transition for the identification and quantification (deuterated analogs of each target as internal standards) of each analyte. The limits of detection of the method were 0.26, 0.94, 1.5, 1.1, and 2.0 ng mL(-1), for cocaine, BZE, codeine, morphine and 6-MAM, respectively; whereas, relative standard deviations of intra- and inter-day precision were lower than 8 and 11%, respectively, and intra- and inter-day analytical recoveries ranged from 94±4 to 105±3%. The small volume of urine required (20 μL), combined with the simplicity of the analytical technique makes it a useful procedure for screening/quantifying drugs of abuse. The method was successfully applied to the analysis of urine from polydrug abusers. Copyright © 2013 Elsevier B.V. All rights reserved.
Ma, Huilian; Jin, Jing; Li, Yun; Chen, Jiping
2017-10-08
A method of comprehensive screening of the target and non-target volatile organic compounds (VOCs) in industrial exhaust gas using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed. In this paper, two types of solid phase adsorption column were compared, and the Tenex SS TD Tube was selected. The analytes were enriched into the adsorption tube by constant flow sampling, and detected by TD-GC-MS in full scan mode. Target compounds were quantified by internal standard method, and the quantities of non-target compounds were calculated by response coefficient of toluene. The method detection limits (MDLs) for the 24 VOCs were 1.06 to 5.44 ng, and MDLs could also be expressed as 0.004 to 0.018 mg/m 3 assuming that the sampling volume was 300 mL. The average recoveries were in the range of 78.4% to 89.4% with the relative standard deviations (RSDs) of 3.9% to 14.4% ( n =7). The established analytical method was applied for the comprehensive screening of VOCs in a waste incineration power plant in Dalian city. Twenty-nine VOCs were identified. In these compounds, only five VOCs were the target compounds set in advance, which accounted for 26.7% of the total VOCs identified. Therefore, this study further proved the importance of screening non-target compounds in the analysis of VOCs in industrial exhaust gas, and has certain reference significance for the complete determination of VOCs distribution.
Using model-based screening to help discover unknown environmental contaminants.
McLachlan, Michael S; Kierkegaard, Amelie; Radke, Michael; Sobek, Anna; Malmvärn, Anna; Alsberg, Tomas; Arnot, Jon A; Brown, Trevor N; Wania, Frank; Breivik, Knut; Xu, Shihe
2014-07-01
Of the tens of thousands of chemicals in use, only a small fraction have been analyzed in environmental samples. To effectively identify environmental contaminants, methods to prioritize chemicals for analytical method development are required. We used a high-throughput model of chemical emissions, fate, and bioaccumulation to identify chemicals likely to have high concentrations in specific environmental media, and we prioritized these for target analysis. This model-based screening was applied to 215 organosilicon chemicals culled from industrial chemical production statistics. The model-based screening prioritized several recognized organosilicon contaminants and generated hypotheses leading to the selection of three chemicals that have not previously been identified as potential environmental contaminants for target analysis. Trace analytical methods were developed, and the chemicals were analyzed in air, sewage sludge, and sediment. All three substances were found to be environmental contaminants. Phenyl-tris(trimethylsiloxy)silane was present in all samples analyzed, with concentrations of ∼50 pg m(-3) in Stockholm air and ∼0.5 ng g(-1) dw in sediment from the Stockholm archipelago. Tris(trifluoropropyl)trimethyl-cyclotrisiloxane and tetrakis(trifluoropropyl)tetramethyl-cyclotetrasiloxane were found in sediments from Lake Mjøsa at ∼1 ng g(-1) dw. The discovery of three novel environmental contaminants shows that models can be useful for prioritizing chemicals for exploratory assessment.
Guale, Fessessework; Shahreza, Shahriar; Walterscheid, Jeffrey P.; Chen, Hsin-Hung; Arndt, Crystal; Kelly, Anna T.; Mozayani, Ashraf
2013-01-01
Liquid chromatography time-of-flight mass spectrometry (LC–TOF-MS) analysis provides an expansive technique for identifying many known and unknown analytes. This study developed a screening method that utilizes automated solid-phase extraction to purify a wide array of analytes involving stimulants, benzodiazepines, opiates, muscle relaxants, hypnotics, antihistamines, antidepressants and newer synthetic “Spice/K2” cannabinoids and cathinone “bath salt” designer drugs. The extract was applied to LC–TOF-MS analysis, implementing a 13 min chromatography gradient with mobile phases of ammonium formate and methanol using positive mode electrospray. Several common drugs and metabolites can share the same mass and chemical formula among unrelated compounds, but they are structurally different. In this method, the LC–TOF-MS was able to resolve many isobaric compounds by accurate mass correlation within 15 ppm mass units and a narrow retention time interval of less than 10 s of separation. Drug recovery yields varied among spiked compounds, but resulted in overall robust area counts to deliver an average match score of 86 when compared to the retention time and mass of authentic standards. In summary, this method represents a rapid, enhanced screen for blood and urine specimens in postmortem, driving under the influence, and drug facilitated sexual assault forensic toxicology casework. PMID:23118149
Guale, Fessessework; Shahreza, Shahriar; Walterscheid, Jeffrey P; Chen, Hsin-Hung; Arndt, Crystal; Kelly, Anna T; Mozayani, Ashraf
2013-01-01
Liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS) analysis provides an expansive technique for identifying many known and unknown analytes. This study developed a screening method that utilizes automated solid-phase extraction to purify a wide array of analytes involving stimulants, benzodiazepines, opiates, muscle relaxants, hypnotics, antihistamines, antidepressants and newer synthetic "Spice/K2" cannabinoids and cathinone "bath salt" designer drugs. The extract was applied to LC-TOF-MS analysis, implementing a 13 min chromatography gradient with mobile phases of ammonium formate and methanol using positive mode electrospray. Several common drugs and metabolites can share the same mass and chemical formula among unrelated compounds, but they are structurally different. In this method, the LC-TOF-MS was able to resolve many isobaric compounds by accurate mass correlation within 15 ppm mass units and a narrow retention time interval of less than 10 s of separation. Drug recovery yields varied among spiked compounds, but resulted in overall robust area counts to deliver an average match score of 86 when compared to the retention time and mass of authentic standards. In summary, this method represents a rapid, enhanced screen for blood and urine specimens in postmortem, driving under the influence, and drug facilitated sexual assault forensic toxicology casework.
Kim, Junghyun; Suh, Joon Hyuk; Cho, Hyun-Deok; Kang, Wonjae; Choi, Yong Seok; Han, Sang Beom
2016-01-01
A multi-class, multi-residue analytical method based on LC-MS/MS detection was developed for the screening and confirmation of 28 veterinary drug and metabolite residues in flatfish, shrimp and eel. The chosen veterinary drugs are prohibited or unauthorised compounds in Korea, which were categorised into various chemical classes including nitroimidazoles, benzimidazoles, sulfones, quinolones, macrolides, phenothiazines, pyrethroids and others. To achieve fast and simultaneous extraction of various analytes, a simple and generic liquid extraction procedure using EDTA-ammonium acetate buffer and acetonitrile, without further clean-up steps, was applied to sample preparation. The final extracts were analysed by ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The method was validated for each compound in each matrix at three different concentrations (5, 10 and 20 ng g(-1)) in accordance with Codex guidelines (CAC/GL 71-2009). For most compounds, the recoveries were in the range of 60-110%, and precision, expressed as the relative standard deviation (RSD), was in the range of 5-15%. The detection capabilities (CCβs) were below or equal to 5 ng g(-1), which indicates that the developed method is sufficient to detect illegal fishery products containing the target compounds above the residue limit (10 ng g(-1)) of the new regulatory system (Positive List System - PLS).
Geue, Claudia; Wu, Olivia; Xin, Yiqiao; Heggie, Robert; Hutchinson, Sharon; Martin, Natasha K.; Fenwick, Elisabeth; Goldberg, David
2015-01-01
Introduction Studies evaluating the cost-effectiveness of screening for Hepatitis B Virus (HBV) and Hepatitis C Virus (HCV) are generally heterogeneous in terms of risk groups, settings, screening intervention, outcomes and the economic modelling framework. It is therefore difficult to compare cost-effectiveness results between studies. This systematic review aims to summarise and critically assess existing economic models for HBV and HCV in order to identify the main methodological differences in modelling approaches. Methods A structured search strategy was developed and a systematic review carried out. A critical assessment of the decision-analytic models was carried out according to the guidelines and framework developed for assessment of decision-analytic models in Health Technology Assessment of health care interventions. Results The overall approach to analysing the cost-effectiveness of screening strategies was found to be broadly consistent for HBV and HCV. However, modelling parameters and related structure differed between models, producing different results. More recent publications performed better against a performance matrix, evaluating model components and methodology. Conclusion When assessing screening strategies for HBV and HCV infection, the focus should be on more recent studies, which applied the latest treatment regimes, test methods and had better and more complete data on which to base their models. In addition to parameter selection and associated assumptions, careful consideration of dynamic versus static modelling is recommended. Future research may want to focus on these methodological issues. In addition, the ability to evaluate screening strategies for multiple infectious diseases, (HCV and HIV at the same time) might prove important for decision makers. PMID:26689908
ALLEMAN, Brandon W.; SMITH, Amanda R.; BYERS, Heather M.; BEDELL, Bruce; RYCKMAN, Kelli K.; MURRAY, Jeffrey C.; BOROWSKI, Kristi S.
2013-01-01
Objective To create a predictive model for preterm birth (PTB) from available clinical data and serum analytes. Study Design Serum analytes, routine pregnancy screening plus cholesterol and corresponding health information were linked to birth certificate data for a cohort of 2699 Iowa women with serum sampled in the first and second trimester. Stepwise logistic regression was used to select the best predictive model for PTB. Results Serum screening markers remained significant predictors of PTB even after controlling for maternal characteristics. The best predictive model included maternal characteristics, first trimester total cholesterol (TC), TC change between trimesters and second trimester alpha-fetoprotein and inhibin A. The model showed better discriminatory ability than PTB history alone and performed similarly in subgroups of women without past PTB. Conclusions Using clinical and serum screening data a potentially useful predictor of PTB was constructed. Validation and replication in other populations, and incorporation of other measures that identify PTB risk, like cervical length, can be a step towards identifying additional women who may benefit from new or currently available interventions. PMID:23500456
Target screening and confirmation of 35 licit and illicit drugs and metabolites in hair by LC-MSMS.
Lendoiro, Elena; Quintela, Oscar; de Castro, Ana; Cruz, Angelines; López-Rivadulla, Manuel; Concheiro, Marta
2012-04-10
A liquid chromatography-tandem mass spectrometry (LC-MSMS) target screening in 50mg hair was developed and fully validated for 35 analytes (Δ9-tetrahidrocannabinol (THC), morphine, 6-acetylmorphine, codeine, methadone, fentanyl, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, benzoylecgonine, cocaine, lysergic acid diethylamide, ketamine, scopolamine, alprazolam, bromazepam, clonazepam, diazepam, flunitrazepam, 7-aminoflunitrazepam, lorazepam, lormetazepam, nordiazepam, oxazepam, tetrazepam, triazolam, zolpidem, zopiclone, amitriptyline, citalopram, clomipramine, fluoxetine, paroxetine and venlafaxine). Hair decontamination was performed with dichloromethane, and incubation in 2 mL of acetonitrile at 50°C overnight. Extraction procedure was performed in 2 steps, first liquid-liquid extraction, hexane:ethyl acetate (55:45, v:v) at pH 9, followed by solid-phase extraction (Strata-X cartridges). Chromatographic separation was performed in AtlantisT3 (2.1 mm × 100 mm, 3 μm) column, acetonitrile and ammonium formate pH 3 as mobile phase, and 32 min total run time. One transition per analyte was monitored in MRM mode. To confirm a positive result, a second injection monitoring 2 transitions was performed. The method was specific (no endogenous interferences, n=9); LOD was 0.2-50 pg/mg and LOQ 0.5-100 pg/mg; linearity ranged from 0.5-100 to 2000-20,000 pg/mg; imprecision <15%; analytical recovery 85-115%; extraction efficiency 4.1-85.6%; and process efficiency 2.5-207.7%; 27 analytes showed ion suppression (up to -86.2%), 4 ion enhancement (up to 647.1%), and 4 no matrix effect; compounds showed good stability 24-48 h in autosampler. The method was applied to 17 forensic cases. In conclusion, a sensitive and specific target screening of 35 analytes in 50mg hair, including drugs of abuse (THC, cocaine, opiates, amphetamines) and medicines (benzodiazepines, antidepressants) was developed and validated, achieving lower cut-offs than Society of Hair Testing recommendations. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lawton, Zachary E.; Traub, Angelica; Fatigante, William L.; Mancias, Jose; O'Leary, Adam E.; Hall, Seth E.; Wieland, Jamie R.; Oberacher, Herbert; Gizzi, Michael C.; Mulligan, Christopher C.
2017-06-01
Forensic evidentiary backlogs are indicative of the growing need for cost-effective, high-throughput instrumental methods. One such emerging technology that shows high promise in meeting this demand while also allowing on-site forensic investigation is portable mass spectrometric (MS) instrumentation, particularly that which enables the coupling to ambient ionization techniques. While the benefits of rapid, on-site screening of contraband can be anticipated, the inherent legal implications of field-collected data necessitates that the analytical performance of technology employed be commensurate with accepted techniques. To this end, comprehensive analytical validation studies are required before broad incorporation by forensic practitioners can be considered, and are the focus of this work. Pertinent performance characteristics such as throughput, selectivity, accuracy/precision, method robustness, and ruggedness have been investigated. Reliability in the form of false positive/negative response rates is also assessed, examining the effect of variables such as user training and experience level. To provide flexibility toward broad chemical evidence analysis, a suite of rapidly-interchangeable ion sources has been developed and characterized through the analysis of common illicit chemicals and emerging threats like substituted phenethylamines. [Figure not available: see fulltext.
NASA Astrophysics Data System (ADS)
Chang, Ya-Chi; Yeh, Hund-Der
2010-06-01
The constant-head pumping tests are usually employed to determine the aquifer parameters and they can be performed in fully or partially penetrating wells. Generally, the Dirichlet condition is prescribed along the well screen and the Neumann type no-flow condition is specified over the unscreened part of the test well. The mathematical model describing the aquifer response to a constant-head test performed in a fully penetrating well can be easily solved by the conventional integral transform technique under the uniform Dirichlet-type condition along the rim of wellbore. However, the boundary condition for a test well with partial penetration should be considered as a mixed-type condition. This mixed boundary value problem in a confined aquifer system of infinite radial extent and finite vertical extent is solved by the Laplace and finite Fourier transforms in conjunction with the triple series equations method. This approach provides analytical results for the drawdown in a partially penetrating well for arbitrary location of the well screen in a finite thickness aquifer. The semi-analytical solutions are particularly useful for the practical applications from the computational point of view.
[Blood sampling using "dried blood spot": a clinical biology revolution underway?].
Hirtz, Christophe; Lehmann, Sylvain
2015-01-01
Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.
Saleh, Aljona; Stephanson, Niclas Nikolai; Granelli, Ingrid; Villén, Tomas; Beck, Olof
2012-11-15
In this study a rapid liquid chromatography-time-of-flight mass spectrometry method was developed, validated and applied in order to evaluate the potential of this technique for routine urine drug testing. Approximately 800 authentic patient samples were analyzed for amphetamines (amphetamine and methamphetamine), opiates (morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine and codeine-6-glucuronide) and buprenorphines (buprenorphine and buprenorphine-glucuronide) using immunochemical screening assays and mass spectrometry confirmation methods for comparison. The chromatographic application utilized a rapid gradient with high flow and a reversed phase column with 1.8 μm particles. Total analysis time was 4 min. The mass spectrometer operated with an electrospray interface in positive mode with a resolution power of >10,000 at m/z 956. The applied reporting limits were 100 ng/mL for amphetamines and opiates, and 5 ng/mL for buprenorphines, with lower limits of quantification were 2.8-41 ng/mL. Calibration curves showed a linear response with coefficients of correlation of 0.97-0.99. The intra- and interday imprecision in quantification at the reporting limits were <10% for all analytes but for buprenorphines <20%. Method validation data met performance criteria for a qualitative and quantitative method. The liquid chromatography-time-of-flight mass spectrometry method was found to be more selective than the immunochemical method by producing lower rates of false positives (0% for amphetamines and opiates; 3.2% for buprenorphines) and negatives (1.8% for amphetamines; 0.6% for opiates; 0% for buprenorphines). The overall agreement between the two screening methods was between 94.2 and 97.4%. Comparison of data with the confirmation (LC-MS) results for all individual 9 analytes showed that most deviating results were produced in samples with low levels of analytes. False negatives were mainly related to failure of detected peak to meet mass accuracy criteria (±20 mDa). False positives was related to presence of interfering peaks meeting mass accuracy and retention time criteria and occurred mainly at low levels. It is concluded that liquid chromatography-time-of-flight mass spectrometry has potential both as a complement and as replacement of immunochemical screening assays. Copyright © 2012 Elsevier B.V. All rights reserved.
Lei, Kin Fong; Yang, Shih-I; Tsai, Shiao-Wen; Hsu, Hsiao-Ting
2015-03-01
Efficient diagnosis is very important for the prevention and treatment of diseases. Rapid disease screening in ambulatory environment is one of the most pressing needs for disease control. Despite there are many methods to detect the results of immunoassays, quantitative measurement for rapid disease screening is still a great challenge for point-of-care applications. In this study, a fabrication method for depositing carbon nanotube bundles has been successfully developed for realization of functional paper-based microfluidic sensing device. Quantitative detection of label-free immunoassay, i.e., biotin-avidin binding interaction, was demonstrated by direct measurement of the current change of the biosensor after single application of the target analyte. Sensitivity of 0.33 μA/ng mL(-1) and minimal detectable analyte concentration of 25 ng/mL were achieved. The time necessary for the detection was 500 s which is a large reduction compared with the conventional immunoassay. Such paper-based biosensor has the benefits of portability, fast response, simple operation, and low cost and has the potential for the development of rapid disease screening devices. Copyright © 2014 Elsevier B.V. All rights reserved.
Van den Bulcke, Marc; Lievens, Antoon; Barbau-Piednoir, Elodie; MbongoloMbella, Guillaume; Roosens, Nancy; Sneyers, Myriam; Casi, Amaya Leunda
2010-03-01
The detection of genetically modified (GM) materials in food and feed products is a complex multi-step analytical process invoking screening, identification, and often quantification of the genetically modified organisms (GMO) present in a sample. "Combinatory qPCR SYBRGreen screening" (CoSYPS) is a matrix-based approach for determining the presence of GM plant materials in products. The CoSYPS decision-support system (DSS) interprets the analytical results of SYBRGREEN qPCR analysis based on four values: the C(t)- and T(m) values and the LOD and LOQ for each method. A theoretical explanation of the different concepts applied in CoSYPS analysis is given (GMO Universe, "Prime number tracing", matrix/combinatory approach) and documented using the RoundUp Ready soy GTS40-3-2 as an example. By applying a limited set of SYBRGREEN qPCR methods and through application of a newly developed "prime number"-based algorithm, the nature of subsets of corresponding GMO in a sample can be determined. Together, these analyses provide guidance for semi-quantitative estimation of GMO presence in a food and feed product.
Rasche, Claudia; Fournes, Britta; Dirks, Uwe; Speer, Karl
2015-07-17
Some steps of the QuEChERS method for the analysis of pesticides with GC-MS/MS in cereals and dried fruits were improved or simplified. For the latter, a mixing vessel with stator-rotor-system proved to be advantageous. The extraction procedure of dried fruits is much easier and safer than the Ultra Turrax and results in excellent validation data at a concentration level of 0.01mg/kg (116 of 118 analytes with recoveries in the range of 70-120%, 117 of 118 analytes with RSD <20%). After qualifying problematic lipophilic pesticides in fat-rich cereals (fat content >7%), predominantly organochlorines showed recoveries of <70% in quantification when the standard QuEChERS method with water was used. A second extraction was carried out analogous to the QuEChERS method, however, without the addition of water. With this simple modification, the problematic lipophilic pesticides, which had been strongly affected by the fat content of the commodities, could be determined with recoveries above 70% even at a concentration level of 0.01mg/kg. Moreover, a GC-MS/MS screening method for 120 pesticides at a concentration level of 0.01mg/kg was established by employing analyte protectants (ethylglycerol, gulonolactone, and sorbitol). The use of only one standardized calibration, made of an apple purée extract in combination with analyte protectants, allowed for a qualitative and quantitative analysis of 120 pesticides in different matrix extracts (tomato, red pepper, sour cherries, dried apples, black currant powder, raisins, wheat flour, rolled oats, wheat germ). The analyte protectants leveled the differences in the matrix-induced protection effect of the analyzed extracts over a wide range. The majority of the pesticides were analyzed with good analytical results (recoveries in the range of 70-120% and RSD <20%). Copyright © 2015 Elsevier B.V. All rights reserved.
Posch, Tjorben Nils; Pütz, Michael; Martin, Nathalie; Huhn, Carolin
2015-01-01
In this review we introduce the advantages and limitations of electromigrative separation techniques in forensic toxicology. We thus present a summary of illustrative studies and our own experience in the field together with established methods from the German Federal Criminal Police Office rather than a complete survey. We focus on the analytical aspects of analytes' physicochemical characteristics (e.g. polarity, stereoisomers) and analytical challenges including matrix tolerance, separation from compounds present in large excess, sample volumes, and orthogonality. For these aspects we want to reveal the specific advantages over more traditional methods. Both detailed studies and profiling and screening studies are taken into account. Care was taken to nearly exclusively document well-validated methods outstanding for the analytical challenge discussed. Special attention was paid to aspects exclusive to electromigrative separation techniques, including the use of the mobility axis, the potential for on-site instrumentation, and the capillary format for immunoassays. The review concludes with an introductory guide to method development for different separation modes, presenting typical buffer systems as starting points for different analyte classes. The objective of this review is to provide an orientation for users in separation science considering using capillary electrophoresis in their laboratory in the future.
Zarzycki, Paweł K; Slączka, Magdalena M; Zarzycka, Magdalena B; Bartoszuk, Małgorzata A; Włodarczyk, Elżbieta; Baran, Michał J
2011-11-01
This paper is a continuation of our previous research focusing on development of micro-TLC methodology under temperature-controlled conditions. The main goal of present paper is to demonstrate separation and detection capability of micro-TLC technique involving simple analytical protocols without multi-steps sample pre-purification. One of the advantages of planar chromatography over its column counterpart is that each TLC run can be performed using non-previously used stationary phase. Therefore, it is possible to fractionate or separate complex samples characterized by heavy biological matrix loading. In present studies components of interest, mainly steroids, were isolated from biological samples like fish bile using single pre-treatment steps involving direct organic liquid extraction and/or deproteinization by freeze-drying method. Low-molecular mass compounds with polarity ranging from estetrol to progesterone derived from the environmental samples (lake water, untreated and treated sewage waters) were concentrated using optimized solid-phase extraction (SPE). Specific bands patterns for samples derived from surface water of the Middle Pomerania in northern part of Poland can be easily observed on obtained micro-TLC chromatograms. This approach can be useful as simple and non-expensive complementary method for fast control and screening of treated sewage water discharged by the municipal wastewater treatment plants. Moreover, our experimental results show the potential of micro-TLC as an efficient tool for retention measurements of a wide range of steroids under reversed-phase (RP) chromatographic conditions. These data can be used for further optimalization of SPE or HPLC systems working under RP conditions. Furthermore, we also demonstrated that micro-TLC based analytical approach can be applied as an effective method for the internal standard (IS) substance search. Generally, described methodology can be applied for fast fractionation or screening of the whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in biological or environmental samples. Due to low consumption of eluent (usually 0.3-1mL/run) mainly composed of water-alcohol binary mixtures, this method can be considered as environmentally friendly and green chemistry focused analytical tool, supplementary to analytical protocols involving column chromatography or planar micro-fluidic devices. Copyright © 2011 Elsevier Ltd. All rights reserved.
Screening new psychoactive substances in urban wastewater using high resolution mass spectrometry.
González-Mariño, Iria; Gracia-Lor, Emma; Bagnati, Renzo; Martins, Claudia P B; Zuccato, Ettore; Castiglioni, Sara
2016-06-01
Analysis of drug residues in urban wastewater could complement epidemiological studies in detecting the use of new psychoactive substances (NPS), a continuously changing group of drugs hard to monitor by classical methods. We initially selected 52 NPS potentially used in Italy based on seizure data and consumption alerts provided by the Antidrug Police Department and the National Early Warning System. Using a linear ion trap-Orbitrap high resolution mass spectrometer, we designed a suspect screening and a target method approach and compared them for the analysis of 24 h wastewater samples collected at the treatment plant influents of four Italian cities. This highlighted the main limitations of these two approaches, so we could propose requirements for future research. A library of MS/MS spectra of 16 synthetic cathinones and 19 synthetic cannabinoids, for which analytical standards were acquired, was built at different collision energies and is available on request. The stability of synthetic cannabinoids was studied in analytical standards and wastewater, identifying the best analytical conditions for future studies. To the best of our knowledge, these are the first stability data on NPS. Few suspects were identified in Italian wastewater samples, in accordance with recent epidemiological data reporting a very low prevalence of use of NPS in Italy. This study outlines an analytical approach for NPS identification and measurement in urban wastewater and for estimating their use in the population.
Erythrocyte Sedimentation Rate (ESR)
... 3 screens]. Available from: https://labtestsonline.org/understanding/analytes/esr/tab/test/ Lab Tests Online [Internet]. Washington ... 2 screens]. Available from: https://labtestsonline.org/understanding/analytes/esr/tab/sample/ National Heart, Lung, and Blood ...
Salazar, Carolina; Armenta, Jenny M; Shulaev, Vladimir
2012-07-06
In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10-11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary.
Salazar, Carolina; Armenta, Jenny M.; Shulaev, Vladimir
2012-01-01
In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10−11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary. PMID:24957640
Screening-level estimates of mass discharge uncertainty from point measurement methods
The uncertainty of mass discharge measurements associated with point-scale measurement techniques was investigated by deriving analytical solutions for the mass discharge coefficient of variation for two simplified, conceptual models. In the first case, a depth-averaged domain w...
Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes.
Metters, Jonathan P; Kadara, Rashid O; Banks, Craig E
2012-02-21
We report the fabrication of gold screen printed macro electrodes which are electrochemically characterised and contrasted to polycrystalline gold macroelectrodes with their potential analytical application towards the sensing of chromium(III) and (VI) critically explored. It is found that while these gold screen printed macro electrodes have electrode kinetics typically one order of magnitude lower than polycrystalline gold macroelectrodes as is measured via a standard redox probe, in terms of analytical sensing, these gold screen printed macro electrodes mimic polycrystalline gold in terms of their analytical performance towards the sensing of chromium(III) and (VI), whilst boasting additional advantages over the macro electrode due to their disposable one-shot nature and the ease of mass production. An additional advantage of these gold screen printed macro electrodes compared to polycrystalline gold is the alleviation of the requirement to potential cycle the latter to form the required gold oxide which aids in the simplification of the analytical protocol. We demonstrate that gold screen printed macro electrodes allow the low micro-molar sensing of chromium(VI) in aqueous solutions over the range 10 to 1600 μM with a limit of detection (3σ) of 4.4 μM. The feasibility of the analytical protocol is also tested through chromium(VI) detection in environmental samples.
Screen-printed back-to-back electroanalytical sensors.
Metters, Jonathan P; Randviir, Edward P; Banks, Craig E
2014-11-07
We introduce the concept of screen-printed back-to-back electroanalytical sensors where in this facile and generic approach, screen-printed electrodes are printed back-to-back with a common electrical connection to the two working electrodes with the counter and reference electrodes for each connected in the same manner as a normal "traditional" screen-printed sensor would be. This approach utilises the usually redundant back of the screen-printed sensor, converting this "dead-space" into a further electrochemical sensor which results in improvements in the analytical performance. In the use of the back-to-back design, the electrode area is consequently doubled with improvements in the analytical performance observed with the analytical sensitivity (gradient of a plot of peak height/analytical signal against concentration) doubling and the corresponding limit-of-detection being reduced. We also demonstrate that through intelligent electrode design, a quadruple in the observed analytical sensitivity can also be realised when double microband electrodes are used in the back-to-back configuration as long as they are placed sufficiently apart such that no diffusional interaction occurs. Such work is generic in nature and can be facilely applied to a plethora of screen-printed (and related) sensors utilising the commonly overlooked redundant back of the electrode providing facile improvements in the electroanalytical performance.
Li, Wei; Zhang, Min; Wang, Mingyu; Han, Zhantao; Liu, Jiankai; Chen, Zhezhou; Liu, Bo; Yan, Yan; Liu, Zhu
2018-06-01
Brownfield sites pollution and remediation is an urgent environmental issue worldwide. The screening and assessment of remedial alternatives is especially complex owing to its multiple criteria that involves technique, economy, and policy. To help the decision-makers selecting the remedial alternatives efficiently, the criteria framework conducted by the U.S. EPA is improved and a comprehensive method that integrates multiple criteria decision analysis (MCDA) with numerical simulation is conducted in this paper. The criteria framework is modified and classified into three categories: qualitative, semi-quantitative, and quantitative criteria, MCDA method, AHP-PROMETHEE (analytical hierarchy process-preference ranking organization method for enrichment evaluation) is used to determine the priority ranking of the remedial alternatives and the solute transport simulation is conducted to assess the remedial efficiency. A case study was present to demonstrate the screening method in a brownfield site in Cangzhou, northern China. The results show that the systematic method provides a reliable way to quantify the priority of the remedial alternatives.
NASA Astrophysics Data System (ADS)
Zhu, Xiaoyan; Sun, Jianguo; Hao, Haiping; Wang, Guangji; Hu, Xiaoling; Lv, Hua; Gu, Shenghua; Wu, Xiaoming; Xu, Jinyi
2008-05-01
A rapid and sensitive high performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-ESI-MS/MS) detection was developed for the simultaneous determination of multiple angiotensin type 1 receptor antagonists (AT1RAs) WX472, WX581, 1b and telmisartan in rat plasma for the purpose of high-throughout pharmacokinetic screening. The method was operated under selected reaction monitoring (SRM) mode in the positive ion mode. The analytes and the internal standard (pitavastatin) were extracted from 100 [mu]L rat plasma under acidic conditions by liquid-liquid extraction with ethyl acetate. The analytes and internal standard were baseline separated on a Gemini analytical column (3 [mu]m, 150 mm × 2.0 mm) with the adoption of a gradient elution using acetonitrile and 0.05% aqueous formic acid. The standard curves were linear in the concentration ranges of 4.5-900 ng/mL for WX472, 5-1000 ng/mL for WX581 and 0.5-100 ng/mL for 1b and telmisartan. Intra- and inter-batch precisions (R.S.D.%) were all within 15% and the method assessed a quite good accuracy (R.E.%). Recoveries were found to be >65% for all the compounds and no obvious matrix effects were found. This method has been successfully applied to the high-throughput pharmacokinetic screening study for both cassette dosing and cassette analysis of four compounds to rats. Significant drug-drug interactions were observed after cassette dosing. The study suggested that cassette analysis of pooled samples would be a better choice for the high-throughput pharmacokinetic screening of angiotensin type 1 receptor antagonists.
Long-term detection of methyltestosterone (ab-) use by a yeast transactivation system.
Wolf, Sylvi; Diel, Patrick; Parr, Maria Kristina; Rataj, Felicitas; Schänzer, Willhelm; Vollmer, Günter; Zierau, Oliver
2011-04-01
The routinely used analytical method for detecting the abuse of anabolic steroids only allows the detection of molecules with known analytical properties. In our supplementary approach to structure-independent detection, substances are identified by their biological activity. In the present study, urines excreted after oral methyltestosterone (MT) administration were analyzed by a yeast androgen screen (YAS). The aim was to trace the excretion of MT or its metabolites in human urine samples and to compare the results with those from the established analytical method. MT and its two major metabolites were tested as pure compounds in the YAS. In a second step, the ability of the YAS to detect MT and its metabolites in urine samples was analyzed. For this purpose, a human volunteer ingested of a single dose of 5 mg methyltestosterone. Urine samples were collected after different time intervals (0-307 h) and were analyzed in the YAS and in parallel by GC/MS. Whereas the YAS was able to trace MT in urine samples at least for 14 days, the detection limits of the GC/MS method allowed follow-up until day six. In conclusion, our results demonstrate that the yeast reporter gene system could detect the activity of anabolic steroids like methyltestosterone with high sensitivity even in urine. Furthermore, the YAS was able to detect MT abuse for a longer period of time than classical GC/MS. Obviously, the system responds to long-lasting metabolites yet unidentified. Therefore, the YAS can be a powerful (pre-) screening tool with the potential that to be used to identify persistent or late screening metabolites of anabolic steroids, which could be used for an enhancement of the sensitivity of GC/MS detection techniques.
Contamination of dried blood spots - an underestimated risk in newborn screening.
Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia
2018-01-26
Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.
Fernández, Elena; Vidal, Lorena; Iniesta, Jesús; Metters, Jonathan P; Banks, Craig E; Canals, Antonio
2014-03-01
A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid-liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett-Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L(-1) and 9 μg L(-1), respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L(-1)), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.
Cui, Zhentao; Wu, Dan; Zhang, Yong; Ma, Hongmin; Li, He; Du, Bin; Wei, Qin; Ju, Huangxian
2014-01-07
An ultrasensitive multiplexed immunoassay method was developed at a disposable immunosensor array using mesoporous platinum nanoparticles (M-Pt NPs) as nonenzymatic labels. M-Pt NPs were prepared by ultrasonic method and employed to label the secondary antibody (Ab2) for signal amplification. The immunosensor array was constructed by covalently immobilizing capture antibody (Ab1) on graphene modified screen printed carbon electrodes (SPECs). After the sandwich-type immunoreactions, the M-Pt-Ab2 was bound to immunosensor surface to catalyze the electro-reduction of H2O2 reaction, which produced detectable signals for readout of analytes. Using breast cancer related panel of tumor markers (CA125, CA153 and CEA) as model analytes, this method showed wide linear ranges of over 4 orders of magnitude with the detection limits of 0.002 U mL(-1), 0.001 U mL(-1) and 7.0 pg mL(-1) for CA125, CA153 and CEA, respectively. The disposable immunosensor array possessed excellent clinical value in cancer screening as well as convenient point of care diagnostics. Copyright © 2013 Elsevier B.V. All rights reserved.
Strano-Rossi, Sabina; Molaioni, Francesco; Rossi, Francesca; Botrè, Francesco
2005-01-01
This paper describes a rapid gas chromatographic/mass spectrometric (GC/MS) screening method for the detection of drugs of abuse and/or their metabolites in urine. Synthetic stimulants, opiates, cocaine metabolites, cannabinoids--and specifically the acid metabolite of tetrahydrocannabinol (THC-COOH)--can be simultaneously extracted by a single liquid/liquid separation step, at alkaline pH, and assayed as trimethylsilyl derivatives by GC/MS in SIM (selected ion monitoring) mode. All the analytes show a good linearity (R2 > 0.99 for most of the considered substances) in the range 25-1000 ng/mL, with a good reproducibility of both the retention times (CV% <0.7) and the relative abundances of the characteristic diagnostic ions (CV% <13). The limit of detection (LOD) of the method is 25 ng/mL of target compound in human urine for most of the substances investigated, 3 ng/mL for THC-COOH, and 10 ng/mL for norbuprenorphine. Validation of the method allows its application to different fields of forensic analytical toxicology, including antidoping analysis.
NASA Astrophysics Data System (ADS)
Qu, Jianan Y.; Suria, David; Wilson, Brian C.
1998-05-01
The primary goal of these studies was to demonstrate that NIR Raman spectroscopy is feasible as a rapid and reagentless analytic method for clinical diagnostics. Raman spectra were collected on human serum and urine samples using a 785 nm excitation laser and a single-stage holographic spectrometer. A partial east squares method was used to predict the analyte concentrations of interest. The actual concentrations were determined by a standard clinical chemistry. The prediction accuracy of total protein, albumin, triglyceride and glucose in human sera ranged from 1.5 percent to 5 percent which is greatly acceptable for clinical diagnostics. The concentration measurements of acetaminophen, ethanol and codeine inhuman urine have demonstrated the potential of NIR Raman technology in screening of therapeutic drugs and substances of abuse.
Recent advances in immunosensor for narcotic drug detection
Gandhi, Sonu; Suman, Pankaj; Kumar, Ashok; Sharma, Prince; Capalash, Neena; Suri, C. Raman
2015-01-01
Introduction: Immunosensor for illicit drugs have gained immense interest and have found several applications for drug abuse monitoring. This technology has offered a low cost detection of narcotics; thereby, providing a confirmatory platform to compliment the existing analytical methods. Methods: In this minireview, we define the basic concept of transducer for immunosensor development that utilizes antibodies and low molecular mass hapten (opiate) molecules. Results: This article emphasizes on recent advances in immunoanalytical techniques for monitoring of opiate drugs. Our results demonstrate that high quality antibodies can be used for immunosensor development against target analyte with greater sensitivity, specificity and precision than other available analytical methods. Conclusion: In this review we highlight the fundamentals of different transducer technologies and its applications for immunosensor development currently being developed in our laboratory using rapid screening via immunochromatographic kit, label free optical detection via enzyme, fluorescence, gold nanoparticles and carbon nanotubes based immunosensing for sensitive and specific monitoring of opiates. PMID:26929925
Immunoanalysis Methods for the Detection of Dioxins and Related Chemicals
Tian, Wenjing; Xie, Heidi Qunhui; Fu, Hualing; Pei, Xinhui; Zhao, Bin
2012-01-01
With the development of biotechnology, approaches based on antibodies, such as enzyme-linked immunosorbent assay (ELISA), active aryl hydrocarbon immunoassay (Ah-I) and other multi-analyte immunoassays, have been utilized as alternatives to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of dioxin and dioxin-like compounds in environmental and biological samples. These screening methods have been verified as rapid, simple and cost-effective. This paper provides an overview on the development and application of antibody-based approaches, such as ELISA, Ah-I, and multi-analyte immunoassays, covering the sample extraction and cleanup, antigen design, antibody preparation and immunoanalysis. However, in order to meet the requirements for on-site fast detection and relative quantification of dioxins in the environment, further optimization is needed to make these immuno-analytical methods more sensitive and easy to use. PMID:23443395
Cullinan, David B; Hondrogiannis, George; Henderson, Terry J
2008-04-15
Two-dimensional 1H-13C HSQC (heteronuclear single quantum correlation) and fast-HMQC (heteronuclear multiple quantum correlation) pulse sequences were implemented using a sensitivity-enhanced, cryogenic probehead for detecting compounds relevant to the Chemical Weapons Convention present in complex mixtures. The resulting methods demonstrated exceptional sensitivity for detecting the analytes at trace level concentrations. 1H-13C correlations of target analytes at < or = 25 microg/mL were easily detected in a sample where the 1H solvent signal was approximately 58,000-fold more intense than the analyte 1H signals. The problem of overlapping signals typically observed in conventional 1H spectroscopy was essentially eliminated, while 1H and 13C chemical shift information could be derived quickly and simultaneously from the resulting spectra. The fast-HMQC pulse sequences generated magnitude mode spectra suitable for detailed analysis in approximately 4.5 h and can be used in experiments to efficiently screen a large number of samples. The HSQC pulse sequences, on the other hand, required roughly twice the data acquisition time to produce suitable spectra. These spectra, however, were phase-sensitive, contained considerably more resolution in both dimensions, and proved to be superior for detecting analyte 1H-13C correlations. Furthermore, a HSQC spectrum collected with a multiplicity-edited pulse sequence provided additional structural information valuable for identifying target analytes. The HSQC pulse sequences are ideal for collecting high-quality data sets with overnight acquisitions and logically follow the use of fast-HMQC pulse sequences to rapidly screen samples for potential target analytes. Use of the pulse sequences considerably improves the performance of NMR spectroscopy as a complimentary technique for the screening, identification, and validation of chemical warfare agents and other small-molecule analytes present in complex mixtures and environmental samples.
Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas
2014-10-21
In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.
Xie, Zhengjun; Wang, Yang; Chen, Yisheng; Xu, Xueming; Jin, Zhengyu; Ding, Yunlian; Yang, Na; Wu, Fengfeng
2017-09-01
Reliable screening of histamine in fish was of urgent importance for food safety. This work presented a highly selective surface enhanced Raman spectroscopy (SERS) method mediated by thin-layer chromatography (TLC), which was tailored for identification and quantitation of histamine. Following separation and derivatization with fluram, plates were assayed with SERS, jointly using silver nanoparticle and NaCl. The latter dramatically suppressed the masking effect caused by excessive fluram throughout the plate, thus offering clear baseline and intensive Raman fingerprints specific to the analyte. Under optimized conditions, the usability of this method was validated by identifying the structural fingerprints of both targeted and unknown compounds in fish samples. Meanwhile, the quantitative results of this method agreed with those by an HPLC method officially suggested by EU for histamine determination. Showing remarkable cost-efficiency and user-friendliness, this facile TLC-SERS method was indeed screening-oriented and may be more attractive to controlling laboratories of limited resource. Copyright © 2017 Elsevier Ltd. All rights reserved.
Goldie, Sue
2006-11-01
Cervical cancer remains a leading cause of cancer death among women living in low-resource settings. In the last 3 decades, cytologic screening has -in theory -been available and yet more than 6 million women have died of this preventable disease. The necessary resources, infrastructure, and technological expertise, together with the need for repeated screenings at regular intervals, make cytologic screening difficult to implement in poor countries. As noncytologic approaches for the detection of HPV, simple visual screening methods for anogenital lesions caused by HPV, and the availability of an HPV-16/18 vaccine will enhance the linkage between screening and treatment, multiple factors will need to be considered when designing new, or modifying existing prevention strategies. Countryspecific decisions regarding the best strategy for cervical cancer control will need to rely on data from many sources and take into account complex epidemiologic, economic, social, political, and cultural factors, and be made despite uncertainty and incomplete information. A rigorous decision analytic approach using computerbased modeling methods enables linkage of the knowledge gained from empirical studies to real-world situations. This chapter provides an introduction to these methods, reviews lessons learned from cost-effectiveness analyses of cervical cancer screening in developed and developing countries, and emphasizes important qualitative themes to consider in designing cervical cancer prevention policies.
Recent developments and new applications of tandem mass spectrometry in newborn screening.
Rinaldo, Piero; Tortorelli, Silvia; Matern, Dietrich
2004-08-01
To summarize recent developments in the field of newborn screening related to the use of tandem mass spectrometry as an analytic platform. Novel inborn errors of metabolism with informative amino acid and/or acylcarnitine profiles have been characterized, increasing the complexity of the differential diagnosis of abnormal results. In addition, methods have been developed for the analysis in dried blood spots of steroids and lysosomal enzymes. Previously unrecognized genotype/phenotype correlations have been found among cohorts of patients whose conditions were diagnosed by screening rather than clinically. Several government entities and professional organizations have issued position statements on newborn screening, and worldwide outcome studies continue to underscore the clinical and financial benefits of expanded newborn screening. Although it is done inconsistently, newborn screening in the United States is undergoing a rapid expansion driven by the introduction of tandem mass spectrometry in at least 34 state programs. This technology is also used to detect disease markers beyond acylcarnitines and amino acids, as both primary and second-tier tests. In addition to analytic improvements, there is a trend toward the development of joint programs not limited to contiguous geographic areas, often based upon public-private partnerships. This review will summarize several new developments in the field that have occurred since early 2003 and will mention others likely to occur in the near future.
Colorectal Cancer Awareness for Women via Facebook: A Pilot Study.
Brittain, Kelly; Pennings Kamp, Kendra J; Salaysay, Zachary
Colorectal cancer is the third leading cause of cancer death among U.S. women. Women report being screened for colorectal cancer less often than men, and if colorectal cancer screening guidelines were routinely followed, approximately 60% of colorectal cancer deaths could be prevented. Many colorectal cancer screening interventions have not used Facebook, which is the most popular social media site among women. Little is known about engaging women in colorectal cancer screening and risk reduction information using Facebook. The "Colorectal Cancer Screening Awareness for Women" Facebook page was created to promote colorectal cancer screening and risk reduction awareness among women. Facebook posts targeted women aged 45-64 years and highlighted colorectal cancer screening methods, guidelines, and colorectal cancer risk reduction strategies. Demographics and data about the women's interactions with the page were collected using Facebook analytics and analyzed. The majority of the 391 users of the Colorectal Cancer Screening Awareness for Women Facebook page were women aged 45-54 years (56.5%). The most "liked" posts were related to colorectal cancer risk reduction behaviors. In an effort to increase routine colorectal cancer screening and colorectal cancer risk reduction behaviors, gastroenterology nurses and practices should consider Facebook as a good method to regularly engage women in colorectal cancer screening and colorectal cancer risk reduction information.
Development and application of a general plasmid reference material for GMO screening.
Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang
The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.
Confining potential in momentum space
NASA Technical Reports Server (NTRS)
Norbury, John W.; Kahana, David E.; Maung, Khin Maung
1992-01-01
A method is presented for the solution in momentum space of the bound state problem with a linear potential in r space. The potential is unbounded at large r leading to a singularity at small q. The singularity is integrable, when regulated by exponentially screening the r-space potential, and is removed by a subtraction technique. The limit of zero screening is taken analytically, and the numerical solution of the subtracted integral equation gives eigenvalues and wave functions in good agreement with position space calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurley, D.F.; Whitehouse, J.M.
A dedicated low-flow groundwater sample collection system was designed for implementation in a post-closure ACL monitoring program at the Yaworski Lagoon NPL site in Canterbury, Connecticut. The system includes dedicated bladder pumps with intake ports located in the screened interval of the monitoring wells. This sampling technique was implemented in the spring of 1993. The system was designed to simultaneously obtain samples directly from the screened interval of nested wells in three distinct water bearing zones. Sample collection is begun upon stabilization of field parameters. Other than line volume, no prior purging of the well is required. It was foundmore » that dedicated low-flow sampling from the screened interval provides a method of representative sample collection without the bias of suspended solids introduced by traditional techniques of pumping and bailing. Analytical data indicate that measured chemical constituents are representative of groundwater migrating through the screened interval. Upon implementation of the low-flow monitoring system, analytical results exhibited a decrease in concentrations of some organic compounds and metals. The system has also proven to be a cost effective alternative to pumping and bailing which generate large volumes of purge water requiring containment and disposal.« less
Liao, Wei-Ching; Chuang, Min-Chieh; Ho, Ja-An Annie
2013-12-15
Genetically modified (GM) technique, one of the modern biomolecular engineering technologies, has been deemed as profitable strategy to fight against global starvation. Yet rapid and reliable analytical method is deficient to evaluate the quality and potential risk of such resulting GM products. We herein present a biomolecular analytical system constructed with distinct biochemical activities to expedite the computational detection of genetically modified organisms (GMOs). The computational mechanism provides an alternative to the complex procedures commonly involved in the screening of GMOs. Given that the bioanalytical system is capable of processing promoter, coding and species genes, affirmative interpretations succeed to identify specified GM event in terms of both electrochemical and optical fashions. The biomolecular computational assay exhibits detection capability of genetically modified DNA below sub-nanomolar level and is found interference-free by abundant coexistence of non-GM DNA. This bioanalytical system, furthermore, sophisticates in array fashion operating multiplex screening against variable GM events. Such a biomolecular computational assay and biosensor holds great promise for rapid, cost-effective, and high-fidelity screening of GMO. Copyright © 2013 Elsevier B.V. All rights reserved.
Weaver, Abigail A; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya
2013-07-02
Reports of low-quality pharmaceuticals have been on the rise in the past decade, with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide and also screen for substitute pharmaceuticals, such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers such as chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain 12 lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a "color bar code" which can be analyzed visually by comparison with standard outcomes. Although quantification of the APIs is poor compared with conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API as well as formulations containing APIs that have been "cut" with inactive ingredients.
Weaver, Abigail A.; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya
2013-01-01
Reports of low quality pharmaceuticals have been on the rise in the last decade with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide, and also screen for substitute pharmaceuticals such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers like chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain twelve lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a “color bar code” which can be analyzed visually by comparison to standard outcomes. While quantification of the APIs is poor compared to conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API, as well as formulations containing APIs that have been “cut” with inactive ingredients. PMID:23725012
Kong, Cong; Wang, Yang; Huang, Yuanfei; Yu, Huijuan
2018-05-11
A quick screening method of more than 200 pharmaceutical and other residues in aquatic foods based on ultrahigh-performance liquid chromatography-quadrupole-Orbitrap mass spectrometry (UHPLC-Q/Orbitrap MS) was established. In this method, after the addition of 200 μL of 1 M EDTA-Na 2 , 2 g of each sample homogenate was extracted successively with 10 mL of acetonitrile and 10 mL of ethyl acetate. The extracts were combined, dried under nitrogen flow, and redissolved in 0.1% formic acid in acetonitrile/water (4:6, v/v) for analysis. The prepared samples were analyzed by UHPLC- Q/Orbitrap MS system in Full MS/ddMS 2 (full-scan data-dependent MS/MS) mode. Compound identification was performed through comparison of the sample data with the database for standard chemicals, including the retention time, precursor ion, product ions, and isotope pattern for all 206 compounds. Five different aquatic food matrices (carp, shrimp, crab, eel, and mussel) spiked with the analytes at 1, 10, and 50 ng/g were evaluated to assess recoveries, precision, matrix effects, stability, and detection limits using the method. UHPLC analyses required 25 min, and 178-200 analytes met identification criteria at 50 ng/g depending on the matrix. Furthermore, practical application of this method for real samples displayed strong screening capability. Graphical abstract A quick screening method of >200 pharmaceutical and other residues in aquatic foods based on ultrahighperformance liquid chromatography-quadrupole-Orbitrap mass spectrometer was established. Fivedifferent aquatic food matrices, including carp, shrimp, crab, eel and mussel, were studied to evaluatescreen limit at 1, 10 and 50 μg·kg-1 level. Results suggest the high reliability, high time-efficiency and goodsimplicity of the method.
Heller, David N; Nochetto, Cristina B; Rummel, Nathan G; Thomas, Michael H
2006-07-26
A method was developed for detection of a variety of polar drug residues in eggs via liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). A total of twenty-nine target analytes from four drug classes-sulfonamides, tetracyclines, fluoroquinolones, and beta-lactams-were extracted from eggs using a hydrophilic-lipophilic balance polymer solid-phase extraction (SPE) cartridge. The extraction technique was developed for use at a target concentration of 100 ng/mL (ppb), and it was applied to eggs containing incurred residues from dosed laying hens. The ESI source was tuned using a single, generic set of tuning parameters, and analytes were separated with a phenyl-bonded silica cartridge column using an LC gradient. In a related study, residues of beta-lactam drugs were not found by LC/MS/MS in eggs from hens dosed orally with beta-lactam drugs. LC/MS/MS performance was evaluated on two generations of ion trap mass spectrometers, and key operational parameters were identified for each instrument. The ion trap acquisition methods could be set up for screening (a single product ion) or confirmation (multiple product ions). The lower limit of detection for screening purposes was 10-50 ppb (sulfonamides), 10-20 ppb (fluoroquinolones), and 10-50 ppb (tetracyclines), depending on the drug, instrument, and acquisition method. Development of this method demonstrates the feasibility of generic SPE, LC, and MS conditions for multiclass LC/MS residue screening.
Stanley, Shawn M R; Wee, Wei Khee; Lim, Boon Huat; Foo, Hsiao Ching
2007-04-01
Direct-injection LC-LC hybrid tandem MS methods have been developed for undertaking broad-based screening for acidic drugs in protein-precipitated plasma and neutral doping agents in equine urine. In both analyses, analytes present in the matrix were trapped using a HLB extraction column before being refocused and separated on a Chromolith RP-18e monolithic analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Each method has been optimised by the adoption of a mobile phase and gradient that was tailored to enhance ionisation in the MS source while maintaining good chromatographic behaviour for the majority of the target drugs. The analytical column eluent was fed into the heated nebulizer (HN) part of the Duospray interface attached to a 4000 QTRAP mass spectrometer. Information dependent acquisition (IDA) with dynamic background subtraction (DBS) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. Ninety-one percent of acidic drugs in protein-precipitated plasma and 80% of the neutral compounds in equine urine were detected when spiked at 10 ng/ml.
Kasten, Shane A; Zulli, Steven; Jones, Jonathan L; Dephillipo, Thomas; Cerasoli, Douglas M
2014-12-01
Chemical warfare nerve agents (CWNAs) are extremely toxic organophosphorus compounds that contain a chiral phosphorus center. Undirected synthesis of G-type CWNAs produces stereoisomers of tabun, sarin, soman, and cyclosarin (GA, GB, GD, and GF, respectively). Analytical-scale methods were developed using a supercritical fluid chromatography (SFC) system in tandem with a mass spectrometer for the separation, quantitation, and isolation of individual stereoisomers of GA, GB, GD, and GF. Screening various chiral stationary phases (CSPs) for the capacity to provide full baseline separation of the CWNAs revealed that a Regis WhelkO1 (SS) column was capable of separating the enantiomers of GA, GB, and GF, with elution of the P(+) enantiomer preceding elution of the corresponding P(-) enantiomer; two WhelkO1 (SS) columns had to be connected in series to achieve complete baseline resolution. The four diastereomers of GD were also resolved using two tandem WhelkO1 (SS) columns, with complete baseline separation of the two P(+) epimers. A single WhelkO1 (RR) column with inverse stereochemistry resulted in baseline separation of the GD P(-) epimers. The analytical methods described can be scaled to allow isolation of individual stereoisomers to assist in screening and development of countermeasures to organophosphorus nerve agents. © 2014 The Authors. Chirality published by John Wiley Periodicals, Inc.
Obstetrical complications associated with abnormal maternal serum markers analytes.
Gagnon, Alain; Wilson, R Douglas
2008-10-01
To review the obstetrical outcomes associated with abnormally elevated or decreased level of one or more of the most frequently measured maternal serum marker analytes used in screening for aneuploidy. To provide guidance to facilitate the management of pregnancies that have abnormal levels of one of more markers and to assess the usefulness of these markers as a screening test. Perinatal outcomes associated with abnormal levels of maternal serum markers analytes are compared with the outcomes of pregnancies with normal levels of the same analytes or the general population. The Cochrane Library and Medline were searched for English-language articles published from 1966 to February 2007, relating to maternal serum markers and perinatal outcomes. Search terms included PAPP-A (pregnancy associated plasma protein A), AFP (alphafetoprotein), hCG (human chorionic gonadotropin), estriol, unconjugated estriol, inhibin, inhibin-A, maternal serum screen, triple marker screen, quadruple screen, integrated prenatal screen, first trimester screen, and combined prenatal screen. All study types were reviewed. Randomized controlled trials were considered evidence of the highest quality, followed by cohort studies. Key individual studies on which the recommendations are based are referenced. Supporting data for each recommendation are summarized with evaluative comments and references. The evidence was evaluated using the guidelines developed by the Canadian Task Force on Preventive Health Care. The evidence collected was reviewed by the Genetics Committee of the Society of Obstetricians and Gynaecologists of Canada. The benefit expected from this guideline is to facilitate early detection of potential adverse pregnancy outcomes when risks are identified at the time of a maternal serum screen. It will help further stratification of risk and provide options for pregnancy management to minimize the impact of pregnancy complications. The potential harms resulting from such practice are associated with the so called false positive (i.e., uncomplicated pregnancies labelled at increased risk for adverse perinatal outcomes), the potential stress associated with such a label, and the investigations performed for surveillance in this situation. No cost-benefit analysis is available to assess costs and savings associated with this guideline. SUMMARY STATEMENTS: 1. An unexplained level of a maternal serum marker analyte is defined as an abnormal level after confirmation of gestational age by ultrasound and exclusion of maternal, fetal, or placental causes for the abnormal level. (III) 2. Abnormally elevated levels of serum markers are associated with adverse pregnancy outcomes in twin pregnancies, after correction for the number of fetuses. Spontaneous or planned mutifetal reductions may result in abnormal elevations of serum markers. (II-2) RECOMMENDATIONS: 1. In the first trimester, an unexplained low PAPP-A (< 0.4 MoM) and/or a low hCG (< 0.5 MoM) are associated with an increased frequency of adverse obstetrical outcomes, and, at present, no specific protocol for treatment is available. (II-2A) In the second trimester, an unexplained elevation of maternal serum AFP (> 2.5 MoM), hCG (> 3.0 MoM), and/or inhibin-A (> or =2.0 MoM) or a decreased level of maternal serum AFP (< 0.25 MoM) and/or unconjugated estriol (< 0.5 MoM) are associated with an increased frequency of adverse obstetrical outcomes, and, at present, no specific protocol for treatment is available. (II-2A) 2. Pregnant woman with an unexplained elevated PAPP-A or hCG in the first trimester and an unexplained low hCG or inhibin-A and an unexplained elevated unconjugated estriol in the second trimester should receive normal antenatal care, as this pattern of analytes is not associated with adverse perinatal outcomes. (II-2A) 3. The combination of second or third trimester placenta previa and an unexplained elevated maternal serum AFP should increase the index of suspicion for placenta accreta, increta, or percreta. (II-2B) An assessment (ultrasound, MRI) of the placental-uterine interface should be performed. Abnormal invasion should be strongly suspected, and the planning of delivery location and technique should be done accordingly. (III-C) 4. A prenatal consultation with the medical genetics department is recommended for low unconjugated estriol levels (<0.3 MoM), as this analyte pattern can be associated with genetic conditions. (II-2B) 5. The clinical management protocol for identification of potential adverse obstetrical outcomes should be guided by one or more abnormal maternal serum marker analyte value rather than the false positive screening results for the trisomy 21 and/or the trisomy 18 screen. (II-2B) 6. Pregnant woman who are undergoing renal dialysis or who have had a renal transplant should be offered maternal serum screening, but interpretation of the result is difficult as the level of serum hCG is not reliable. (II-2A) 7. Abnormal maternal uterine artery Doppler in association with elevated maternal serum AFP, hCG, or inhibin-A or decreased PAPP-A identifies a group of women at greater risk of IUGR and gestational hypertension with proteinuria. Uterine artery Doppler measurements may be used in the evaluation of an unexplained abnormal level of either of these markers. (II-2B) 8. Further research is recommended to identify the best protocol for pregnancy management and surveillance in women identified at increased risk of adverse pregnancy outcomes based on an abnormality of a maternal serum screening analyte. (III-A) 9. In the absence of evidence supporting any specific surveillance protocol, an obstetrician should be consulted in order to establish a fetal surveillance plan specific to the increased obstetrical risks (maternal and fetal) identified. This plan may include enhanced patient education on signs and symptoms of the most common complications, increased frequency of antenatal visits, increased ultrasound (fetal growth, amniotic fluid levels), and fetal surveillance (biophysical profile, arterial and venous Doppler), and cervical length assessment. (III-A) 10. Limited information suggests that, in women with elevated hCG in the second trimester and/or abnormal uterine artery Doppler (at 22-24 weeks), low-dose aspirin (60-81 mg daily) is associated with higher birthweight and lower incidence of gestational hypertension with proteinuria. This therapy may be used in women who are at risk. (II-2B) 11. Further studies are recommended in order to assess the benefits of low-dose aspirin, low molecular weight heparin, or other therapeutic options in pregnancies determined to be at increased risk on the basis of an abnormal maternal serum screening analyte. (III-A) 12. Multiple maternal serum markers screening should not be used at present as a population-based screening method for adverse pregnancy outcomes (such as preeclampsia, placental abruption, and stillbirth) outside an established research protocol, as sensitivity is low, false positive rates are high, and no management protocol has been shown to clearly improve outcomes. (II-2D) When maternal serum screening is performed for the usual clinical indication (fetal aneuploidy and/or neural tube defect), abnormal analyte results can be utilized for the identification of pregnancies at risk and to direct their clinical management. (II-2B) Further studies are recommended to determine the optimal screening method for poor maternal and/or perinatal outcomes. (III-A).
Sell, Bartosz; Sniegocki, Tomasz; Zmudzki, Jan; Posyniak, Andrzej
2018-04-01
Reported here is a new analytical multiclass method based on QuEChERS technique, which has proven to be effective in diagnosing fatal poisoning cases in animals. This method has been developed for the determination of analytes in liver samples comprising rodenticides, carbamate and organophosphorus pesticides, coccidiostats and mycotoxins. The procedure entails addition of acetonitrile and sodium acetate to 2 g of homogenized liver sample. The mixture was shaken intensively and centrifuged for phase separation, which was followed by an organic phase transfer into a tube containing sorbents (PSA and C18) and magnesium sulfate, then it was centrifuged, the supernatant was filtered and analyzed by liquid chromatography tandem mass spectrometry. A validation of the procedure was performed. Repeatability variation coefficients <15% have been achieved for most of the analyzed substances. Analytical conditions allowed for a successful separation of variety of poisons with the typical screening detection limit at ≤10 μg/kg levels. The method was used to investigate more than 100 animals poisoning incidents and proved that is useful to be used in animal forensic toxicology cases.
Chen, Guilin; Huang, Bill X; Guo, Mingquan
2018-05-21
Medicinal plants have played an important role in maintaining human health for thousands of years. However, the interactions between the active components in medicinal plants and some certain biological targets during a disease are still unclear in most cases. To conduct the high-throughput screening for small active molecules that can interact with biological targets, which is of great theoretical significance and practical value. The ultrafiltration mass spectrometry (UF-LC/MS) is a powerful bio-analytical method by combining affinity ultrafiltration and liquid chromatography-mass spectrometry (LC/MS), which could rapidly screen and identify small active molecules that bind to biological targets of interest at the same time. Compared with other analytical methods, affinity UF-LC/MS has the characteristics of fast, sensitive and high throughput, and is especially suitable for the complicated extracts of medicinal plants. In this review, the basic principle, characteristics and some most recent challenges in UF-LC/MS have been demonstrated. Meanwhile, the progress and applications of affinity UF-LC/MS in the discovery of the active components from natural medicinal plants and the interactions between small molecules and biological target proteins are also briefly summarised. In addition, the future directions for UF-LC/MS are also prospected. Affinity UF-LC/MS is a powerful tool in studies on the interactions between small active molecules and biological protein targets, especially in the high-throughput screening of active components from the natural medicinal plants. Copyright © 2018 John Wiley & Sons, Ltd.
Zhang, Xindi; Warren, Jim; Corter, Arden; Goodyear-Smith, Felicity
2016-01-01
This paper describes development of a prototype data analytics portal for analysis of accumulated screening results from eCHAT (electronic Case-finding and Help Assessment Tool). eCHAT allows individuals to conduct a self-administered lifestyle and mental health screening assessment, with usage to date chiefly in the context of primary care waiting rooms. The intention is for wide roll-out to primary care clinics, including secondary school based clinics, resulting in the accumulation of population-level data. Data from a field trial of eCHAT with sexual health questions tailored to youth were used to support design of a data analytics portal for population-level data. The design process included user personas and scenarios, screen prototyping and a simulator for generating large-scale data sets. The prototype demonstrates the promise of wide-scale self-administered screening data to support a range of users including practice managers, clinical directors and health policy analysts.
Liew, Deborah; Linge, Kathryn L; Joll, Cynthia A; Heitz, Anna; Charrois, Jeffrey W A
2012-06-08
Simultaneous quantitation of 6 halonitromethanes (HNMs) and 5 haloacetamides (HAAms) was achieved with a simplified liquid-liquid extraction (LLE) method, followed by gas chromatography-mass spectrometry. Stability tests showed that brominated tri-HNMs immediately degraded in the presence of ascorbic acid, sodium sulphite and sodium borohydride, and also reduced in samples treated with ammonium chloride, or with no preservation. Both ammonium chloride and ascorbic acid were suitable for the preservation of HAAms. Ammonium chloride was most suitable for preserving both HNMs and HAAms, although it is recommended that samples be analysed as soon as possible after collection. While groundwater samples exhibited a greater analytical bias compared to other waters, the good recoveries (>90%) of most analytes in tap water suggest that the method is very appropriate for determining these analytes in treated drinking waters. Application of the method to water from three drinking water treatment plants in Western Australia indicating N-DBP formation did occur, with increased detections after chlorination. The method is recommended for low-cost, rapid screening of both HNMs and HAAms in drinking water. Copyright © 2012 Elsevier B.V. All rights reserved.
De Dominicis, Emiliano; Commissati, Italo; Suman, Michele
2012-09-01
In the food industry, it is frequently necessary to check the quality of an ingredient to decide whether to use it in production and/or to have an idea of the final possible contamination of the finished product. The current need to quickly separate and identify relevant contaminants within different classes, often with legal residue limits on the order of 1-100 µg kg(-1), has led to the need for more effective analytical methods. With thousands of organic compounds present in complex food matrices, the development of new analytical solutions leaned towards simplified extraction/clean-up procedures and chromatography coupled with mass spectrometry. Efforts must also be made regarding the instrumental phase to overcome sensitivity/selectivity limits and interferences. For this purpose, high-resolution full scan analysis in mass spectrometry is an interesting alternative to the traditional tandem mass approach. A fast method for extracting and purifying bakery matrices was therefore developed and combined with the exploitation of ultra-high-pressure liquid chromatography (UHPLC) coupled to a Orbitrap Exactive™ high-resolution mass spectrometer (HRMS). Extracts of blank, naturally contaminated and fortified minicakes, prepared through a combined use of industrial and pilot plant production lines, were analyzed at different concentration levels (1-100 µg kg(-1)) of various contaminants: a limit of detection at 10 µg kg(-1) was possible for most of the analytes within all the categories analyzed, including pesticides, aflatoxins, trichothecene toxins and veterinary drugs. The application of accurate mass targeted screening described in this article demonstrates that current single-stage HRMS analytical instrumentation is well equipped to meet the challenges posed by chemical contaminants in the screening of both bakery raw materials and finished products. Copyright © 2012 John Wiley & Sons, Ltd.
Brock, Robert D.; Murtagh, Lucinda K.
1994-01-01
Twenty-two bottom-sediment samples were collected from Town Lake in Austin, Texas, in 1991 and 1992 and analyzed for chlorinated insecticides by a reconnaissance-quality, electron-capture gas chromatography screening method developed by the U.S. Geological Survey (USGS). Four different chlorinated insecticides (aldrin, chlordane, dieldrin, and p,p'-DDT) and two degradation products of p,p'-DDT (p,p'-DDD and p,p'-DDE) were detected in these samples. The most significant insecticides detected were chlordane, which was detected in 20 of the 22 samples at concentrations that ranged from 26 to 140 micrograms per kilogram, and p,p'-DDT, which was detected in all 22 samples at concen- trations that ranged from 5 to 40 micrograms per kilogram. Degradation products of p,p'-DDT were detected in all 22 samples. Concentrations of p,p'-DDD ranged from not detected to 117 micrograms per kilogram and for p,p'-DDE from 9 to 97 micrograms per kilogram. Of the 22 samples collected, 15 also were analyzed by the standard USGS laboratory analytical method for chlorinated insecticides to determine the comparability of the two methods. Correlation coefficients were calculated for chlordane (0.8662), p,p'-DDT (0.6393), p,p'-DDD (0.9401), p,p'-DDE (0.8595), and dieldrin (0.3819). A paired sign test at the 95 percent confidence level showed no significant difference between the screening method and laboratory analytical method for all detected insecticides except aldrin. P-values were calculated from the data for chlordane (l.0000), p,p'-DDT (0.1796), p,p'-DDD (l,0000), p,p'-DDE (0.1796), and dieldrin (0.2891).
Elmiger, Marco P; Poetzsch, Michael; Steuer, Andrea E; Kraemer, Thomas
2018-03-06
High resolution mass spectrometry and modern data independent acquisition (DIA) methods enable the creation of general unknown screening (GUS) procedures. However, even when DIA is used, its potential is far from being exploited, because often, the untargeted acquisition is followed by a targeted search. Applying an actual GUS (including untargeted screening) produces an immense amount of data that must be dealt with. An optimization of the parameters regulating the feature detection and hit generation algorithms of the data processing software could significantly reduce the amount of unnecessary data and thereby the workload. Design of experiment (DoE) approaches allow a simultaneous optimization of multiple parameters. In a first step, parameters are evaluated (crucial or noncrucial). Second, crucial parameters are optimized. The aim in this study was to reduce the number of hits, without missing analytes. The obtained parameter settings from the optimization were compared to the standard settings by analyzing a test set of blood samples spiked with 22 relevant analytes as well as 62 authentic forensic cases. The optimization lead to a marked reduction of workload (12.3 to 1.1% and 3.8 to 1.1% hits for the test set and the authentic cases, respectively) while simultaneously increasing the identification rate (68.2 to 86.4% and 68.8 to 88.1%, respectively). This proof of concept study emphasizes the great potential of DoE approaches to master the data overload resulting from modern data independent acquisition methods used for general unknown screening procedures by optimizing software parameters.
Goldie, Sue
2006-11-01
Cervical cancer remains a leading cause of cancer death among women living in low-resource settings. In the last 3 decades, cytologic screening has -in theory -been available and yet more than 6 million women have died of this preventable disease. The necessary resources, infrastructure, and technological expertise, together with the need for repeated screenings at regular intervals, make cytologic screening difficult to implement in poor countries. As noncytologic approaches for the detection of HPV, simple visual screening methods for anogenital lesions caused by HPV, and the availability of an HPV-16/18 vaccine will enhance the linkage between screening and treatment, multiple factors will need to be considered when designing new, or modifying existing prevention strategies. Countryspecific decisions regarding the best strategy for cervical cancer control will need to rely on data from many sources and take into account complex epidemiologic, economic, social, political, and cultural factors, and be made despite uncertainty and incomplete information. A rigorous decision analytic approach using computerbased modeling methods enables linkage of the knowledge gained from empirical studies to real-world situations. This chapter provides an introduction to these methods, reviews lessons learned from cost-effectiveness analyses of cervical cancer screening in developed and developing countries, and emphasizes important qualitative themes to consider in designing cervical cancer prevention policies. © 2006 International Federation of Gynecology and Obstetrics.
Assessment of circulating copy number variant detection for cancer screening.
Molparia, Bhuvan; Nichani, Eshaan; Torkamani, Ali
2017-01-01
Current high-sensitivity cancer screening methods, largely utilizing correlative biomarkers, suffer from false positive rates that lead to unnecessary medical procedures and debatable public health benefit overall. Detection of circulating tumor DNA (ctDNA), a causal biomarker, has the potential to revolutionize cancer screening. Thus far, the majority of ctDNA studies have focused on detection of tumor-specific point mutations after cancer diagnosis for the purpose of post-treatment surveillance. However, ctDNA point mutation detection methods developed to date likely lack either the scope or analytical sensitivity necessary to be useful for cancer screening, due to the low (<1%) ctDNA fraction derived from early stage tumors. On the other hand, tumor-derived copy number variant (CNV) detection is hypothetically a superior means of ctDNA-based cancer screening for many tumor types, given that, relative to point mutations, each individual tumor CNV contributes a much larger number of ctDNA fragments to the overall pool of circulating free DNA (cfDNA). A small number of studies have demonstrated the potential of ctDNA CNV-based screening in select cancer types. Here we perform an in silico assessment of the potential for ctDNA CNV-based cancer screening across many common cancers, and suggest ctDNA CNV detection shows promise as a broad cancer screening methodology.
Recommendations for accreditation of laboratories in molecular biology of hematologic malignancies.
Flandrin-Gresta, Pascale; Cornillet, Pascale; Hayette, Sandrine; Gachard, Nathalie; Tondeur, Sylvie; Mauté, Carole; Cayuela, Jean-Michel
2015-01-01
Over recent years, the development of molecular biology techniques has improved the hematological diseases diagnostic and follow-up. Consequently, these techniques are largely used in the biological screening of these diseases; therefore the Hemato-oncology molecular diagnostics laboratories must be actively involved in the accreditation process according the ISO 15189 standard. The French group of molecular biologists (GBMHM) provides requirements for the implementation of quality assurance for the medical molecular laboratories. This guideline states the recommendations for the pre-analytical, analytical (methods validation procedures, quality controls, reagents), and post-analytical conditions. In addition, herein we state a strategy for the internal quality control management. These recommendations will be regularly updated.
Guo, Tianyang; Fang, Pingping; Jiang, Juanjuan; Zhang, Feng; Yong, Wei; Liu, Jiahui; Dong, Yiyang
2016-11-04
A rapid method to screen and quantify multi-class analytic targets in red wine has been developed by direct analysis in real time (DART) coupled with triple quadruple tandem mass spectrometry (QqQ-MS). A modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure was used for increasing analytical speed and reducing matrix effect, and the multiple reaction monitoring (MRM) in DART-MS/MS ensured accurate analysis. One bottle of wine containing 50 pesticides and 12 adulterants, i.e., preservatives, antioxidant, sweeteners, and azo dyes, could be totally determined less than 12min. This method exhibited proper linearity (R 2 ≥0.99) in the range of 1-1000ng/mL for pesticides and 10-5000ng/mL for adulterants. The limits of detection (LODs) were obtained in a 0.5-50ng/mL range for pesticides and 5-50ng/mL range for adulterants, and the limits of quantification (LOQs) were in a 1-100ng/mL range for pesticides and 10-250ng/mL range for adulterants. Three spiked levels for each analyte in wine were evaluated, and the recoveries were in a scope of 75-120%. The results demonstrated DART-MS/MS was a rapid and simple method, and could be applied to rapid analyze residual pesticides and illegal adulterants in a large quantities of red wine. Copyright © 2016 Elsevier B.V. All rights reserved.
Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices.
Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam
2017-12-01
Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MS E mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. Graphical Abstract.
Using In Silico Fragmentation to Improve Routine Residue Screening in Complex Matrices
NASA Astrophysics Data System (ADS)
Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Mirjam
2017-12-01
Targeted residue screening requires the use of reference substances in order to identify potential residues. This becomes a difficult issue when using multi-residue methods capable of analyzing several hundreds of analytes. Therefore, the capability of in silico fragmentation based on a structure database ("suspect screening") instead of physical reference substances for routine targeted residue screening was investigated. The detection of fragment ions that can be predicted or explained by in silico software was utilized to reduce the number of false positives. These "proof of principle" experiments were done with a tool that is integrated into a commercial MS vendor instrument operating software (UNIFI) as well as with a platform-independent MS tool (Mass Frontier). A total of 97 analytes belonging to different chemical families were separated by reversed phase liquid chromatography and detected in a data-independent acquisition (DIA) mode using ion mobility hyphenated with quadrupole time of flight mass spectrometry. The instrument was operated in the MSE mode with alternating low and high energy traces. The fragments observed from product ion spectra were investigated using a "chopping" bond disconnection algorithm and a rule-based algorithm. The bond disconnection algorithm clearly explained more analyte product ions and a greater percentage of the spectral abundance than the rule-based software (92 out of the 97 compounds produced ≥1 explainable fragment ions). On the other hand, tests with a complex blank matrix (bovine liver extract) indicated that the chopping algorithm reports significantly more false positive fragments than the rule based software. [Figure not available: see fulltext.
On the Use of Accelerated Test Methods for Characterization of Advanced Composite Materials
NASA Technical Reports Server (NTRS)
Gates, Thomas S.
2003-01-01
A rational approach to the problem of accelerated testing for material characterization of advanced polymer matrix composites is discussed. The experimental and analytical methods provided should be viewed as a set of tools useful in the screening of material systems for long-term engineering properties in aerospace applications. Consideration is given to long-term exposure in extreme environments that include elevated temperature, reduced temperature, moisture, oxygen, and mechanical load. Analytical formulations useful for predictive models that are based on the principles of time-based superposition are presented. The need for reproducible mechanisms, indicator properties, and real-time data are outlined as well as the methodologies for determining specific aging mechanisms.
Giovannetti, Rita; Alibabaei, Leila; Zannotti, Marco; Ferraro, Stefano; Petetta, Laura
2013-01-01
The composition of sedimentary pigments in the Antarctic lake at Edmonson Point has been investigated and compared with the aim to provide a useful analytical method for pigments separation and identification, providing reference data for future assessment of possible changes in environmental conditions. Reversed phase high performance liquid chromatography (HPLC) with electrospray-mass spectrometry (ESI-MS) detection and diode array detection (DAD) has been used to identify light screening and light harvesting pigments. The results are discussed in terms of local environmental conditions.
Screening and assessment tools for pediatric malnutrition.
Huysentruyt, Koen; Vandenplas, Yvan; De Schepper, Jean
2016-06-18
The ideal measures for screening and assessing undernutrition in children remain a point of discussion in literature. This review aims to provide an overview of recent advances in the nutritional screening and assessment methods in children. This review focuses on two major topics that emerged in literature since 2015: the practical endorsement of the new definition for pediatric undernutrition, with a focus on anthropometric measurements and the search for a consensus on pediatric nutritional screening tools in different settings. Few analytical tools exist for the assessment of the nutritional status in children. The subjective global nutritional assessment has been validated by anthropometric as well as clinical outcome parameters. Nutritional screening can help in selecting patients that benefit the most from a full nutritional assessment. Two new screening tools have been developed for use in a general (mixed) hospital population, and one for a population of children with cancer. The value of screening tools in different disease-specific and outpatient pediatric populations remains to be proven.
Many EPA programs, including those under the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Response, Compensation, and Liability Act (CERCLA), require subsurface characterization and monitoring to detect ground-water contamination and provide data to deve...
Zhang, Xinglei; Liu, Yan; Zhang, Jinghua; Hu, Zhong; Hu, Bin; Ding, Liying; Jia, Li; Chen, Huanwen
2011-09-15
High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD=8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes. Copyright © 2011 Elsevier B.V. All rights reserved.
Katz, B.G.; Collins, J.J.
1998-01-01
A cooperative study between the Florida Department of Environmental Protection (FDEP) and the U.S. Geological Survey was conducted to assess the integrity of selected water-quality data collected at 150 sites in the FDEP Surface-Water Ambient Monitoring Program (SWAMP) in Florida. The assessment included determining the consistency of the water-quality data collected statewide, including commonality of monitoring procedures and analytes, screening of the gross validity of a chemical analysis, and quality assurance and quality control (QA/QC) procedures. Four tests were used to screen data at selected SWAMP sites to estimate the gross validity of selected chemical data: (1) the ratio of dissolved solids (in milligrams per liter) to specific conductance (in microsiemens per centimeter); (2) the ratio of total cations (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); (3) the ratio of total anions (in milliequivalents per liter) multiplied by 100 to specific conductance (in microsiemens per centimeter); and (4) the ionic charge-balance error. Although the results of the four screening tests indicate that the chemical data generally are quite reliable, the extremely small number of samples (less than 5 percent of the total number of samples) with sufficient chemical information to run the tests may not provide a representative indication of the analytical accuracy of all laboratories in the program. In addition to the four screening tests, unusually low or high values were flagged for field and laboratory pH (less than 4.0 and greater than 9.0) and specific conductance (less than 10 and greater than 10,000 microsiemens per centimeter). The numbers of flagged data were less than 1 percent of the 19,937 water samples with pH values and less than 0.6 percent of the 16,553 water samples with specific conductance values. Thirty-four agencies responded to a detailed questionnaire that was sent to more than 60 agencies involved in the collection and analysis of surface-water-quality data for SWAMP. The purpose of the survey was to evaluate quality assurance methods and consistency of methods statewide. Information was compiled and summarized on monitoring network design, data review and upload procedures, laboratory and field sampling methods, and data practices. Currently, most agencies that responded to the survey follow FDEP-approved QA/QC protocol for sampling and have quality assurance practices for recording and reporting data. Also, most agencies responded that calibration procedures were followed in the laboratory for analysis of data, but no responses were given about the specific procedures. Approximately 50 percent of the respondents indicated that laboratory analysis methods have changed over time. With so many laboratories involved in analyzing samples for SWAMP, it is difficult to compare water quality from one site to another due to different reporting conventions for chemical constituents and different analytical methods over time. Most agencies responded that calibration methods are followed in the field, but no specific details were provided. Grab samples are the most common method of collection. Other data screening procedures are necessary to further evaluate the validity of chemical data collected at SWAMP sites. High variability in the concentration of targeted constituents may signal analytical problems, but more likely changes in concentration are related to hydrologic conditions. This underscores the need for accurate measurements of discharge, lake stage, tidal stage at the time of sampling so that changes in constituent concentrations can be properly evaluated and fluxes (loads) of nutrients or metals, for example, can be calculated and compared over time.
Caldeira, Letícia Gomes Magnago; Santos, Flávio Alves; de Oliveira, Andréa Melo Garcia; Lima, Josefa Abucater; de Souza, Leonardo Francisco; da Silva, Guilherme Resende; de Assis, Débora Cristina Sampaio
2017-01-01
A multiresidue method by UHPLC/MS-MS was optimized and validated for the screening and semiquantitative detection of antimicrobials residues from tetracyclines, aminoglycosides, quinolones, lincosamides, β-lactams, sulfonamides, and macrolides families in eggs. A qualitative approach was used to ensure adequate sensitivity to detect residues at the level of interest, defined as maximum residue limit (MRL), or less. The applicability of the methods was assessed by analyzing egg samples from hens that had been subjected to pharmacological treatment with neomycin, enrofloxacin, lincomycin, oxytetracycline, and doxycycline during five days and after discontinuation of medication (10 days). The method was adequate for screening all studied analytes in eggs, since the performance parameters ensured a false-compliant rate below or equal to 5%, except for flumequine. In the analyses of eggs from laying hens subjected to pharmacological treatment, all antimicrobial residues were detected throughout the experimental period, even after discontinuation of medication, except for neomycin, demonstrating the applicability of the method for analyses of antimicrobial residues in eggs. PMID:29181222
Setiawan, Didik; Kotsopoulos, Nikolaos; Wilschut, Jan C.; Postma, Maarten J.; Connolly, Mark P.
2016-01-01
Background Cervical cancer poses a substantial burden in terms of morbidity, mortality, and economic losses, especially in low/middle-income countries. HPV vaccination and/or cervical cancer screening among females may reduce the burden of HPV-related diseases, including cervical cancer. However, limited funds may impede the implementation of population-based programmes. Governmental investments in the prevention of infectious disease may have broader economic and fiscal benefits, which are not accounted in conventional economic analyses. This study estimates the broader economic and fiscal impacts of implementing HPV vaccination and/or cervical cancer screening in Indonesia from the perspective of the government. Methods A government-perspective quantitative analytic framework was applied to assess the Net Present Value (NPV) of investment on cervical cancer prevention strategies including HPV vaccination, cervical screening and its combination in Indonesia. All monetary values were presented in International Dollars (I$). Results Based on a cohort of 10,000,000 Indonesian 12-year-old females, it was estimated that HPV vaccination and/or cervical cancer screening result in a positive NPV for the Indonesian government. The combination of cervical screening and HPV vaccination generated a substantial reduction of cervical cancer incidence and HPV-related mortality of 87,862 and 19,359, respectively. It was estimated that HPV vaccination in combination with cervical screening is the most favorable option for cervical cancer prevention (NPV I$2.031.786.000), followed by HPV vaccination alone (NPV I$1.860.783.000) and cervical screening alone (NPV I$375.244.000). Conclusion In addition to clinical benefits, investing in HPV vaccination and cervical screening may yield considerable fiscal benefits for the Indonesian governments due to lifelong benefits resulting from reduction of cervical cancer-related morbidity and mortality. PMID:27490258
Roemmelt, Andreas T; Steuer, Andrea E; Poetzsch, Michael; Kraemer, Thomas
2014-12-02
Forensic and clinical toxicological screening procedures are employing liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques with information-dependent acquisition (IDA) approaches more and more often. It is known that the complexity of a sample and the IDA settings might prevent important compounds from being triggered. Therefore, data-independent acquisition (DIA) methods should be more suitable for systematic toxicological analysis (STA). The DIA method sequential window acquisition of all theoretical fragment-ion spectra (SWATH), which uses Q1 windows of 20-35 Da for data-independent fragmentation, was systematically investigated for its suitability for STA. Quality of SWATH-generated mass spectra were evaluated with regard to mass error, relative abundance of the fragments, and library hits. With the Q1 window set to 20-25 Da, several precursors pass Q1 at the same time and are fragmented, thus impairing the library search algorithms to a different extent: forward fit was less affected than reverse fit and purity fit. Mass error was not affected. The relative abundance of the fragments was concentration dependent for some analytes and was influenced by cofragmentation, especially of deuterated analogues. Also, the detection rate of IDA compared to SWATH was investigated in a forced coelution experiment (up to 20 analytes coeluting). Even using several different IDA settings, it was observed that IDA failed to trigger relevant compounds. Screening results of 382 authentic forensic cases revealed that SWATH's detection rate was superior to IDA, which failed to trigger ∼10% of the analytes.
Beloglazova, N V; Goryacheva, I Yu; Rusanova, T Yu; Yurasov, N A; Galve, R; Marco, M-P; De Saeger, S
2010-07-05
A new rapid method which allows simultaneous one step detection of two analytes of different nature (2,4,6,-trichlorophenol (TCP) and ochratoxin A (OTA)) in red wine was developed. It was based on a column test with three separate immunolayers: two test layers and one control layer. Each layer consisted of sepharose gel with immobilized anti-OTA (OTA test layer), anti-TCP (TCP test layer) or anti-HRP (control layer) antibodies. Analytes bind to the antibodies in the corresponding test layer while sample flows through the column. Then a mixture of OTA-HRP and TCP-HRP in appropriate dilutions was used, followed by the application of chromogenic substrate. Colour development of the test layer occurred when the corresponding analyte was absent in the sample. HRP-conjugates bound to anti-HRP antibody in the control layer independently of presence or absence of analytes and a blue colour developed in the control layer. Cut-off values for both analytes were 2 microg L(-1). The described method was applied to the simultaneous detection of TCP and OTA in wine samples. To screen the analytes in red wine samples, clean-up columns were used for sample pre-treatment in combination with the test column. Results were confirmed by chromatographic methods. Copyright 2010 Elsevier B.V. All rights reserved.
Pilot proficiency testing study for second tier congenital adrenal hyperplasia newborn screening.
De Jesús, Víctor R; Simms, David A; Schiffer, Jarad; Kennedy, Meredith; Mei, Joanne V; Hannon, W Harry
2010-11-11
Congenital adrenal hyperplasia (CAH) is caused by inherited defects in steroid biosynthesis. The Newborn Screening Quality Assurance Program (NSQAP) initiated a pilot, dried-blood spot (DBS)-based proficiency testing program designed to investigate materials and laboratory performance for second tier CAH screening by tandem mass spectrometry (MS/MS). The ratio of 17-α-hydroxyprogesterone (17-OHP), androstenedione (4-AD) and cortisol is used as an indicator of CAH in laboratory protocols for second tier analysis of DBS specimens. DBS prepared by NSQAP contained a range of steroid concentrations resulting in different clinical ratios. Laboratories received blind-coded DBS specimens and reported results to NSQAP for evaluation. Quantitative values reported by participants for 17-OHP, 4-AD, and cortisol, reflected small differences in their analytical methods. Average quantitative values for 17-OHP increased from 81% to 107% recovery over the 3.5-year period; cortisol recoveries increased from 61.9% to 89.5%; and 4-AD recoveries decreased from 184% to 68%. Laboratory participation in the CAH second tier proficiency testing program has resulted in improved analyte recoveries and enhanced sample preparation methodologies. NSQAP services for the second tier CAH analysis in DBS demonstrate the need for surveillance to ensure harmonization and continuous improvements, and to achieve sustained high-performance of newborn screening laboratories worldwide. Published by Elsevier B.V.
Cost-Effectiveness of Three Rounds of Mammography Breast Cancer Screening in Iranian Women
Haghighat, Shahpar; Akbari, Mohammad Esmaeil; Yavari, Parvin; Javanbakht, Mehdi; Ghaffari, Shahram
2016-01-01
Background Breast cancer is the most common cancer in Iranian women as is worldwide. Mammography screening has been introduced as a beneficial method for reducing mortality and morbidity of this disease. Objectives We developed an analytical model to assess the cost effectiveness of an organized mammography screening program in Iran for early detection of the breast cancer. Patients and Methods This study is an economic evaluation of mammography screening program among Iranian woman aged 40 - 70 years. A decision tree and Markov model were applied to estimate total quality adjusted life years (QALY) and lifetime costs. Results The results revealed that the incremental cost effectiveness ratio (ICER) of mammography screening in Iranian women in the first round was Int. $ 37,350 per QALY gained. The model showed that the ICER in the second and third rounds of screening program were Int. $ 141,641 and Int. $ 389,148 respectively. Conclusions Study results identified that mammography screening program was cost-effective in 53% of the cases, but incremental cost per QALY in the second and third rounds of screening are much higher than the accepted payment threshold of Iranian health system. Thus, evaluation of other screening strategies would be useful to identify more cost-effective program. Future studies with new national data can improve the accuracy of our finding and provide better information for health policy makers for decision making. PMID:27366315
Albu, Silvia A; Al-Karmi, Salma A; Vito, Alyssa; Dzandzi, James P K; Zlitni, Aimen; Beckford-Vera, Denis; Blacker, Megan; Janzen, Nancy; Patel, Ramesh M; Capretta, Alfredo; Valliant, John F
2016-01-20
A convenient method to prepare radioiodinated tetrazines was developed, such that a bioorthogonal inverse electron demand Diels-Alder reaction can be used to label biomolecules with iodine-125 for in vitro screening and in vivo biodistribution studies. The tetrazine was prepared by employing a high-yielding oxidative halo destannylation reaction that concomitantly oxidized the dihydrotetrazine precursor. The product reacts quickly and efficiently with trans-cyclooctene derivatives. Utility was demonstrated through antibody and hormone labeling experiments and by evaluating products using standard analytical methods, in vitro assays, and quantitative biodistribution studies where the latter was performed in direct comparison to Bolton-Hunter and direct iodination methods. The approach described provides a convenient and advantageous alternative to conventional protein iodination methods that can expedite preclinical development and evaluation of biotherapeutics.
Chen, Shuo; Chang, Quanying; Yin, Kai; He, Qunying; Deng, Yongxiu; Chen, Bo; Liu, Chengbin; Wang, Ying; Wang, Liping
2017-06-14
In this study, a paper spray ionization mass spectrometric (PS-MS) method was developed for the rapid in situ screening and simultaneous quantitative analysis of bisphenol A and its analogues, i.e., bisphenol S, bisphenol F, and bisphenol AF, in food packaging products. At the optimal PS-MS conditions, the calibration curves of bisphenols in the range of 1-100 μg/mL were linear. The correlation coefficients were higher than 0.998, and the LODs of the target compounds were 0.1-0.3 μg/mL. After a simple treatment by dichloromethane on the surface, the samples were analyzed by PS-MS in situ for rapid screening without a traditional sample pretreatment procedure, such as powdering, extraction, and enrichment steps. The analytical time of the PS-MS method was less than 1 min. In comparison with conventional HPLC-MS/MS, it was demonstrated that PS-MS was a more effective high-throughput screening and quantitative analysis method.
Zhang, Li; Luo, Xin; Niu, Zengyuan; Ye, Xiwen; Tang, Zhixu; Yao, Peng
2015-03-20
A new analytical method was established and validated for the analysis of 19 substances of very high concern (SVHCs) in textiles, including phthalic acid esters (PAEs), organotins (OTs), perfluorochemicals (PFCs) and flame retardants (FRs). After ultrasonic extraction in methanol, the textile samples were analyzed by high performance liquid chromatography-hybrid linear ion trap Orbitrap high resolution mass spectrometry (HPLC-LTQ/Orbitrap). The values of LOQ were in the range of 2-200mg/kg. Recoveries at two levels (at the LOQ and at half the limit of regulation) ranged from 68% to 120%, and the repeatability was lower than 13%. This method was successfully applied to the screening of SVHCs in commercial textile samples and is useful for the fast screening of various SVHCs. Copyright © 2015 Elsevier B.V. All rights reserved.
Kasten, Shane A; Zulli, Steven; Jones, Jonathan L; Dephillipo, Thomas; Cerasoli, Douglas M
2014-01-01
Chemical warfare nerve agents (CWNAs) are extremely toxic organophosphorus compounds that contain a chiral phosphorus center. Undirected synthesis of G-type CWNAs produces stereoisomers of tabun, sarin, soman, and cyclosarin (GA, GB, GD, and GF, respectively). Analytical-scale methods were developed using a supercritical fluid chromatography (SFC) system in tandem with a mass spectrometer for the separation, quantitation, and isolation of individual stereoisomers of GA, GB, GD, and GF. Screening various chiral stationary phases (CSPs) for the capacity to provide full baseline separation of the CWNAs revealed that a Regis WhelkO1 (SS) column was capable of separating the enantiomers of GA, GB, and GF, with elution of the P(+) enantiomer preceding elution of the corresponding P(–) enantiomer; two WhelkO1 (SS) columns had to be connected in series to achieve complete baseline resolution. The four diastereomers of GD were also resolved using two tandem WhelkO1 (SS) columns, with complete baseline separation of the two P(+) epimers. A single WhelkO1 (RR) column with inverse stereochemistry resulted in baseline separation of the GD P(–) epimers. The analytical methods described can be scaled to allow isolation of individual stereoisomers to assist in screening and development of countermeasures to organophosphorus nerve agents. Chirality 26:817–824, 2014. © 2014 The Authors. Chirality published by John Wiley Periodicals, Inc. PMID:25298066
Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.
Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja
2016-11-01
High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.
Capillary device refilling. [liquid rocket propellant tank tests
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Merino, F.; Symons, E. P.
1980-01-01
An analytical and experimental study was conducted dealing with refilling start baskets (capillary devices) with settled fluid. A computer program was written to include dynamic pressure, screen wicking, multiple-screen barriers, standpipe screens, variable vehicle mass for computing vehicle acceleration, and calculation of tank outflow rate and vapor pullthrough height. An experimental apparatus was fabricated and tested to provide data for correlation with the analytical model; the test program was conducted in normal gravity using a scale-model capillary device and ethanol as the test fluid. The test data correlated with the analytical model; the model is a versatile and apparently accurate tool for predicting start basket refilling under actual mission conditions.
NASA Astrophysics Data System (ADS)
Salmon, Neil A.
2017-10-01
Aperture synthesis for passive millimetre wave imaging provides a means to screen people for concealed threats in the extreme near-field configuration of a portal, a regime where the imager to subject distance is of the order of both the required depth-of-field and the field-of-view. Due to optical aberrations, focal plane array imagers cannot deliver the large depth-of-fields and field-of-views required in this regime. Active sensors on the other hand can deliver these but face challenges of illumination, speckle and multi-path issues when imaging canyon regions of the body. Fortunately an aperture synthesis passive millimetre wave imaging system can deliver large depth-of-fields and field-of-views, whilst having no speckle effects, as the radiometric emission from the human body is spatially incoherent. Furthermore, as in portal security screening scenarios the aperture synthesis imaging technique delivers a half-wavelength spatial resolution, it can effectively screen the whole of the human body. Some recent measurements are presented that demonstrate the three-dimensional imaging capability of extended sources using a 22 GHz aperture synthesis system. A comparison is made between imagery generated via the analytic Fourier transform and a gridding fast Fourier transform method. The analytic Fourier transform enables aliasing in the imagery to be more clearly identified. Some initial results are also presented of how the Gerchberg technique, an image enhancement algorithm used in radio astronomy, is adapted for three-dimensional imaging in security screening. This technique is shown to be able to improve the quality of imagery, without adding extra receivers to the imager. The requirements of a walk through security screening system for use at entrances to airport departure lounges are discussed, concluding that these can be met by an aperture synthesis imager.
Garrido-Delgado, Rocío; Arce, Lourdes; Valcárcel, Miguel
2012-01-01
The potential of a headspace device coupled to multi-capillary column-ion mobility spectrometry has been studied as a screening system to differentiate virgin olive oils ("lampante," "virgin," and "extra virgin" olive oil). The last two types are virgin olive oil samples of very similar characteristics, which were very difficult to distinguish with the existing analytical method. The procedure involves the direct introduction of the virgin olive oil sample into a vial, headspace generation, and automatic injection of the volatiles into a gas chromatograph-ion mobility spectrometer. The data obtained after the analysis by duplicate of 98 samples of three different categories of virgin olive oils, were preprocessed and submitted to a detailed chemometric treatment to classify the virgin olive oil samples according to their sensory quality. The same virgin olive oil samples were also analyzed by an expert's panel to establish their category and use these data as reference values to check the potential of this new screening system. This comparison confirms the potential of the results presented here. The model was able to classify 97% of virgin olive oil samples in their corresponding group. Finally, the chemometric method was validated obtaining a percentage of prediction of 87%. These results provide promising perspectives for the use of ion mobility spectrometry to differentiate virgin olive oil samples according to their quality instead of using the classical analytical procedure.
Methods for investigating biosurfactants and bioemulsifiers: a review.
Satpute, Surekha K; Banpurkar, Arun G; Dhakephalkar, Prashant K; Banat, Ibrahim M; Chopade, Balu A
2010-06-01
Microorganisms produce biosurfactant (BS)/bioemulsifier (BE) with wide structural and functional diversity which consequently results in the adoption of different techniques to investigate these diverse amphiphilic molecules. This review aims to compile information on different microbial screening methods, surface active products extraction procedures, and analytical terminologies used in this field. Different methods for screening microbial culture broth or cell biomass for surface active compounds production are also presented and their possible advantages and disadvantages highlighted. In addition, the most common methods for purification, detection, and structure determination for a wide range of BS and BE are introduced. Simple techniques such as precipitation using acetone, ammonium sulphate, solvent extraction, ultrafiltration, ion exchange, dialysis, ultrafiltration, lyophilization, isoelectric focusing (IEF), and thin layer chromatography (TLC) are described. Other more elaborate techniques including high pressure liquid chromatography (HPLC), infra red (IR), gas chromatography-mass spectroscopy (GC-MS), nuclear magnetic resonance (NMR), and fast atom bombardment mass spectroscopy (FAB-MS), protein digestion and amino acid sequencing are also elucidated. Various experimental strategies including static light scattering and hydrodynamic characterization for micelles have been discussed. A combination of various analytical methods are often essential in this area of research and a numbers of trials and errors to isolate, purify and characterize various surface active agents are required. This review introduces the various methodologies that are indispensable for studying biosurfactants and bioemulsifiers.
Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W
2010-04-01
The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).
Analysis of Environmental Contamination resulting from ...
Catastrophic incidents can generate a large number of samples with analytically diverse types including forensic, clinical, environmental, food, and others. Environmental samples include water, wastewater, soil, air, urban building and infrastructure materials, and surface residue. Such samples may arise not only from contamination from the incident but also from the multitude of activities surrounding the response to the incident, including decontamination. This document summarizes a range of activities to help build laboratory capability in preparation for analysis following a catastrophic incident, including selection and development of fit-for-purpose analytical methods for chemical, biological, and radiological contaminants. Fit-for-purpose methods are those which have been selected to meet project specific data quality objectives. For example, methods could be fit for screening contamination in the early phases of investigation of contamination incidents because they are rapid and easily implemented, but those same methods may not be fit for the purpose of remediating the environment to safe levels when a more sensitive method is required. While the exact data quality objectives defining fitness-for-purpose can vary with each incident, a governing principle of the method selection and development process for environmental remediation and recovery is based on achieving high throughput while maintaining high quality analytical results. This paper illu
Mechanical and analytical screening of braided composites for transport fuselage applications
NASA Technical Reports Server (NTRS)
Fedro, Mark J.; Gunther, Christian; Ko, Frank K.
1991-01-01
The mechanics of materials progress in support of the goal of understanding the application of braided composites in a transport aircraft fuselage are summarized. Composites consisting of both 2-D and 3-D braid patterns are investigated. Both consolidation of commingled graphite/PEEK and resin transfer molding of graphite-epoxy braided composite processes are studied. Mechanical tests were used to examine unnotched tension, open hole tension, compression, compression after impact, in-plane shear, out-of-plane tension, bearing, and crippling. Analytical methods are also developed and applied to predict the stiffness and strengths of test specimens. A preliminary study using the test data and analytical results is performed to assess the applicability of braided composites to a commercial aircraft fuselage.
Ng, Tsz-Tsun; So, Pui-Kin; Zheng, Bo; Yao, Zhong-Ping
2015-07-16
Authentication of edible oils is a long-term issue in food safety, and becomes particularly important with the emergence and wide spread of gutter oils in recent years. Due to the very high analytical demand and diversity of gutter oils, a high throughput analytical method and a versatile strategy for authentication of mixed edible oils and gutter oils are highly desirable. In this study, an improved matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for direct analysis of edible oils. This method involved on-target sample loading, automatic data acquisition and simple data processing. MALDI-MS spectra with high quality and high reproducibility have been obtained using this method, and a preliminary spectral database of edible oils has been set up. The authenticity of an edible oil sample can be determined by comparing its MALDI-MS spectrum and principal component analysis (PCA) results with those of its labeled oil in the database. This method is simple and the whole process only takes several minutes for analysis of one oil sample. We demonstrated that the method was sensitive to change in oil compositions and can be used for measuring compositions of mixed oils. The capability of the method for determining mislabeling enables it for rapid screening of gutter oils since fraudulent mislabeling is a common feature of gutter oils. Copyright © 2015 Elsevier B.V. All rights reserved.
Recent developments in urinalysis of metabolites of new psychoactive substances using LC-MS.
Peters, Frank T
2014-08-01
In the last decade, an ever-increasing number of new psychoactive substances (NPSs) have appeared on the recreational drug market. To account for this development, analytical toxicologists have to continuously adapt their methods to encompass the latest NPSs. Urine is the preferred biological matrix for screening analysis in different areas of analytical toxicology. However, the development of urinalysis procedures for NPSs is complicated by the fact that generally little or no information on urinary excretion patterns of such drugs exists when they first appear on the market. Metabolism studies are therefore a prerequisite in the development of urinalysis methods for NPSs. In this article, the literature on the urinalysis of NPS metabolites will be reviewed, focusing on articles published after 2008.
A general analytical platform and strategy in search for illegal drugs.
Johansson, Monika; Fransson, Dick; Rundlöf, Torgny; Huynh, Ngoc-Hang; Arvidsson, Torbjörn
2014-11-01
An effective screening procedure to identify and quantify active pharmaceutical substances in suspected illegal medicinal products is described. The analytical platform, consisting of accurate mass determination with liquid chromatography time-of-flight mass spectrometry (LC-QTOF-MS) in combination with nuclear magnetic resonance (NMR) spectroscopy provides an excellent analytical tool to screen for unknowns in medicinal products, food supplements and herbal formulations. This analytical approach has been successfully applied to analyze thousands of samples. The general screening method usually starts with a methanol extraction of tablets/capsules followed by liquid chromatographic separation on a Halo Phenyl-Hexyl column (2.7μm; 100mm×2.1mm) using an acetonitrile/0.1% formic acid gradient as eluent. The accurate mass of peaks of interest was recorded and a search made against an in-house database containing approximately 4200 substances, mostly pharmaceutical compounds. The search could be general or tailored against different classes of compounds. Hits were confirmed by analyzing a reference substance and/or by NMR. Quantification was normally performed with quantitative NMR (qNMR) spectroscopy. Applications for weight-loss substances like sibutramine and orlistat, sexual potency enhancement (PDE-5 inhibitors), and analgesic drugs are presented in this study. We have also identified prostaglandin analogues in eyelash growth serum, exemplified by isopropyl cloprostenate and bimatoprost. For creams and ointments, matrix solid-phase dispersion (MSPD) was found to give a clean extracts with high recovery prior to LC-MS analyses. The structural elucidation of cetilistat, a new weight-loss substance recently found in illegal medicines purchased over the Internet, is also presented. Copyright © 2014 Elsevier B.V. All rights reserved.
Advances in Assays and Analytical Approaches for Botulinum Toxin Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grate, Jay W.; Ozanich, Richard M.; Warner, Marvin G.
2010-08-04
Methods to detect botulinum toxin, the most poisonous substance known, are reviewed. Current assays are being developed with two main objectives in mind: 1) to obtain sufficiently low detection limits to replace the mouse bioassay with an in vitro assay, and 2) to develop rapid assays for screening purposes that are as sensitive as possible while requiring an hour or less to process the sample an obtain the result. This review emphasizes the diverse analytical approaches and devices that have been developed over the last decade, while also briefly reviewing representative older immunoassays to provide background and context.
Boggia, Raffaella; Casolino, Maria Chiara; Hysenaj, Vilma; Oliveri, Paolo; Zunin, Paola
2013-10-15
Consumer demand for pomegranate juice has considerably grown, during the last years, for its potential health benefits. Since it is an expensive functional food, cheaper fruit juices addition (i.e., grape and apple juices) or its simple dilution, or polyphenols subtraction are deceptively used. At present, time-consuming analyses are used to control the quality of this product. Furthermore these analyses are expensive and require well-trained analysts. Thus, the purpose of this study was to propose a high-speed and easy-to-use shortcut. Based on UV-VIS spectroscopy and chemometrics, a screening method is proposed to quickly screening some common fillers of pomegranate juice that could decrease the antiradical scavenging capacity of pure products. The analytical method was applied to laboratory prepared juices, to commercial juices and to representative experimental mixtures at different levels of water and filler juices. The outcomes were evaluated by means of multivariate exploratory analysis. The results indicate that the proposed strategy can be a useful screening tool to assess addition of filler juices and water to pomegranate juices. Copyright © 2012 Elsevier Ltd. All rights reserved.
Triantis, Theodoros; Tsimeli, Katerina; Kaloudis, Triantafyllos; Thanassoulias, Nicholas; Lytras, Efthymios; Hiskia, Anastasia
2010-05-01
A system of analytical processes has been developed in order to serve as a cost-effective scheme for the monitoring of cyanobacterial toxins on a quantitative basis, in surface and drinking waters. Five cyclic peptide hepatotoxins, microcystin-LR, -RR, -YR, -LA and nodularin were chosen as the target compounds. Two different enzyme-linked immunosorbent assays (ELISA) were validated in order to serve as primary quantitative screening tools. Validation results showed that the ELISA methods are sufficiently specific and sensitive with limits of detection (LODs) around 0.1 microg/L, however, matrix effects should be considered, especially with surface water samples or bacterial mass methanolic extracts. A colorimetric protein phosphatase inhibition assay (PPIA) utilizing protein phosphatase 2A and p-nitrophenyl phosphate as substrate, was applied in microplate format in order to serve as a quantitative screening method for the detection of the toxic activity associated with cyclic peptide hepatotoxins, at concentration levels >0.2 microg/L of MC-LR equivalents. A fast HPLC/PDA method has been developed for the determination of microcystins, by using a short, 50mm C18 column, with 1.8 microm particle size. Using this method a 10-fold reduction of sample run time was achieved and sufficient separation of microcystins was accomplished in less than 3 min. Finally, the analytical system includes an LC/MS/MS method that was developed for the determination of the 5 target compounds after SPE extraction. The method achieves extremely low limits of detection (<0.02 microg/L), in both surface and drinking waters and it is used for identification and verification purposes as well as for determinations at the ppt level. An analytical protocol that includes the above methods has been designed and validated through the analysis of a number of real samples. Copyright 2009 Elsevier Ltd. All rights reserved.
An Overview of Conventional and Emerging Analytical Methods for the Determination of Mycotoxins
Cigić, Irena Kralj; Prosen, Helena
2009-01-01
Mycotoxins are a group of compounds produced by various fungi and excreted into the matrices on which they grow, often food intended for human consumption or animal feed. The high toxicity and carcinogenicity of these compounds and their ability to cause various pathological conditions has led to widespread screening of foods and feeds potentially polluted with them. Maximum permissible levels in different matrices have also been established for some toxins. As these are quite low, analytical methods for determination of mycotoxins have to be both sensitive and specific. In addition, an appropriate sample preparation and pre-concentration method is needed to isolate analytes from rather complicated samples. In this article, an overview of methods for analysis and sample preparation published in the last ten years is given for the most often encountered mycotoxins in different samples, mainly in food. Special emphasis is on liquid chromatography with fluorescence and mass spectrometric detection, while in the field of sample preparation various solid-phase extraction approaches are discussed. However, an overview of other analytical and sample preparation methods less often used is also given. Finally, different matrices where mycotoxins have to be determined are discussed with the emphasis on their specific characteristics important for the analysis (human food and beverages, animal feed, biological samples, environmental samples). Various issues important for accurate qualitative and quantitative analyses are critically discussed: sampling and choice of representative sample, sample preparation and possible bias associated with it, specificity of the analytical method and critical evaluation of results. PMID:19333436
Chebrolu, Kranthi K; Yousef, Gad G; Park, Ryan; Tanimura, Yoshinori; Brown, Allan F
2015-09-15
A high-throughput, robust and reliable method for simultaneous analysis of five carotenoids, four chlorophylls and one tocopherol was developed for rapid screening large sample populations to facilitate molecular biology and plant breeding. Separation was achieved for 10 known analytes and four unknown carotenoids in a significantly reduced run time of 10min. Identity of the 10 analytes was confirmed by their UV-Vis absorption spectras. Quantification of tocopherol, carotenoids and chlorophylls was performed at 290nm, 460nm and 650nm respectively. In this report, two sub two micron particle core-shell columns, Kinetex from Phenomenex (1.7μm particle size, 12% carbon load) and Cortecs from Waters (1.6μm particle size, 6.6% carbon load) were investigated and their separation efficiencies were evaluated. The peak resolutions were >1.5 for all analytes except for chlorophyll-a' with Cortecs column. The ruggedness of this method was evaluated in two identical but separate instruments that produced CV<2 in peak retentions for nine out of 10 analytes separated. Copyright © 2015 Elsevier B.V. All rights reserved.
Cost-effectiveness analysis and HIV screening: the emergency medicine perspective.
Hsu, Heather; Walensky, Rochelle P
2011-07-01
Cost-effectiveness analysis is a useful tool for decisionmakers charged with prioritizing of the myriad medical interventions in the emergency department (ED). This analytic approach may be especially helpful for ranking programs that are competing for scarce resources while attempting to maximize net health benefits. In this article, we review the health economics literature on HIV screening in EDs and introduce the methods of cost-effectiveness analysis for medical interventions. We specifically describe the incremental cost-effectiveness ratio--its calculation, the derivation of ratio components, and the interpretation of these ratios. Copyright © 2011. Published by Mosby, Inc.
NASA Astrophysics Data System (ADS)
Batu, Vedat
2012-01-01
SummaryA new generalized three-dimensional analytical solution is developed for a partially-penetrating vertical rectangular parallelepiped well screen in a confined aquifer by solving the three-dimensional transient ground water flow differential equation in x- y- z Cartesian coordinates system for drawdown by taking into account the three principal hydraulic conductivities ( Kx, Ky, and Kz) along the x- y- z coordinate directions. The fully penetrating screen case becomes equivalent to the single vertical fracture case of Gringarten and Ramey (1973). It is shown that the new solution and Gringarten and Ramey solution (1973) match very well. Similarly, it is shown that this new solution for a horizontally tiny fully penetrating parallelepiped rectangular parallelepiped screen case match very well with Theis (1935) solution. Moreover, it is also shown that the horizontally tiny partially-penetrating parallelepiped rectangular well screen case of this new solution match very well with Hantush (1964) solution. This new analytical solution can also cover a partially-penetrating horizontal well by representing its screen interval with vertically tiny rectangular parallelepiped. Also the solution takes into account both the vertical anisotropy ( azx = Kz/ Kx) as well as the horizontal anisotropy ( ayx = Ky/ Kx) and has potential application areas to analyze pumping test drawdown data from partially-penetrating vertical and horizontal wells by representing them as tiny rectangular parallelepiped as well as line sources. The solution has also potential application areas for a partially-penetrating parallelepiped rectangular vertical fracture. With this new solution, the horizontal anisotropy ( ayx = Ky/ Kx) in addition to the vertical anisotropy ( azx = Kz/ Kx) can also be determined using observed drawdown data. Most importantly, with this solution, to the knowledge of the author, it has been shown the first time in the literature that some well-known well hydraulics problems can also be solved in Cartesian coordinates with some additional advantages other than the conventional cylindrical coordinates method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyholm, N.; Kristensen, P.
1992-04-01
An international ring test involving 14 laboratories was organized on behalf of the Commission of the European Economic Communities (EEC) with the purpose of evaluating two proposed screening methods for assessment of biodegradability in seawater: (a) a shake flask die-away test based primarily on analysis of dissolved organic carbon and (b) a closed bottle test based on determination of dissolved oxygen. Both tests are performed with nutrient-enriched natural seawater as the test medium and with no inoculum added other than the natural seawater microflora. The test methods are seawater versions of the modified OECD screening test and the closed bottlemore » test, respectively, adopted by the Organization for Economic Cooperation and Development (OECD) and by the EEC as tests for ready biodegradability.' The following five chemicals were examined: sodium benzoate, aniline, diethylene glycol, pentaerythritol, and 4-nitrophenol. Sodium benzoate and aniline, which are known to be generally readily biodegradable consistently degraded in practically all tests, thus demonstrating the technical feasibility of the methods. Like in previous ring tests with freshwater screening methods variable results were obtained with the other three compounds, which is believed primarily to be due to site-specific differences between the microflora of the different seawater samples used and to some extent also to differences in the applied concentrations of test material. A positive result with the screening methods indicates that the test substance will most likely degrade relatively rapidly in seawater from the site of collection, while a negative test result does not preclude biodegradability under environmental conditions where the concentrations of chemicals are much lower than the concentrations applied for analytical reasons in screening tests.« less
Yang, Yunjia; Yu, Jianlong; Yin, Jie; Shao, Bing; Zhang, Jing
2014-11-19
This study aimed to develop a selective analytical method for the simultaneous determination of seven bisphenol analogues in beverage and canned food samples by using a new molecularly imprinted polymer (MIP) as a sorbent for solid-phase extraction (SPE). Liquid chromatography coupled to triple-quadruple tandem mass spectrometry (LC-MS/MS) was used to identify and quantify the target analytes. The MIP-SPE method exhibited a higher level of selectivity and purification than the traditional SPE method. The developed procedures were further validated in terms of accuracy, precision, and sensitivity. The obtained recoveries varied from 50% to 103% at three fortification levels and yielded a relative standard deviation (RSD, %) of less than 15% for all of the analytes. The limits of quantification (LOQ) for the seven analytes varied from 0.002 to 0.15 ng/mL for beverage samples and from 0.03 to 1.5 ng/g for canned food samples. This method was used to analyze real samples that were collected from a supermarket in Beijing. Overall, the results revealed that bisphenol A and bisphenol F were the most frequently detected bisphenols in the beverage and canned food samples and that their concentrations were closely associated with the type of packaging material. This study provides an alternative method of traditional SPE extraction for screening bisphenol analogues in food matrices.
Automated image quality assessment for chest CT scans.
Reeves, Anthony P; Xie, Yiting; Liu, Shuang
2018-02-01
Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.
Ojanperä, Ilkka; Kolmonen, Marjo; Pelander, Anna
2012-05-01
Clinical and forensic toxicology and doping control deal with hundreds or thousands of drugs that may cause poisoning or are abused, are illicit, or are prohibited in sports. Rapid and reliable screening for all these compounds of different chemical and pharmaceutical nature, preferably in a single analytical method, is a substantial effort for analytical toxicologists. Combined chromatography-mass spectrometry techniques with standardised reference libraries have been most commonly used for the purpose. In the last ten years, the focus has shifted from gas chromatography-mass spectrometry to liquid chromatography-mass spectrometry, because of progress in instrument technology and partly because of the polarity and low volatility of many new relevant substances. High-resolution mass spectrometry (HRMS), which enables accurate mass measurement at high resolving power, has recently evolved to the stage that is rapidly causing a shift from unit-resolution, quadrupole-dominated instrumentation. The main HRMS techniques today are time-of-flight mass spectrometry and Orbitrap Fourier-transform mass spectrometry. Both techniques enable a range of different drug-screening strategies that essentially rely on measuring a compound's or a fragment's mass with sufficiently high accuracy that its elemental composition can be determined directly. Accurate mass and isotopic pattern acts as a filter for confirming the identity of a compound or even identification of an unknown. High mass resolution is essential for improving confidence in accurate mass results in the analysis of complex biological samples. This review discusses recent applications of HRMS in analytical toxicology.
Loren, Bradley P; Wleklinski, Michael; Koswara, Andy; Yammine, Kathryn; Hu, Yanyang; Nagy, Zoltan K; Thompson, David H; Cooks, R Graham
2017-06-01
A highly integrated approach to the development of a process for the continuous synthesis and purification of diphenhydramine is reported. Mass spectrometry (MS) is utilized throughout the system for on-line reaction monitoring, off-line yield quantitation, and as a reaction screening module that exploits reaction acceleration in charged microdroplets for high throughput route screening. This effort has enabled the discovery and optimization of multiple routes to diphenhydramine in glass microreactors using MS as a process analytical tool (PAT). The ability to rapidly screen conditions in charged microdroplets was used to guide optimization of the process in a microfluidic reactor. A quantitative MS method was developed and used to measure the reaction kinetics. Integration of the continuous-flow reactor/on-line MS methodology with a miniaturized crystallization platform for continuous reaction monitoring and controlled crystallization of diphenhydramine was also achieved. Our findings suggest a robust approach for the continuous manufacture of pharmaceutical drug products, exemplified in the particular case of diphenhydramine, and optimized for efficiency and crystal size, and guided by real-time analytics to produce the agent in a form that is readily adapted to continuous synthesis.
Analytical techniques for steroid estrogens in water samples - A review.
Fang, Ting Yien; Praveena, Sarva Mangala; deBurbure, Claire; Aris, Ahmad Zaharin; Ismail, Sharifah Norkhadijah Syed; Rasdi, Irniza
2016-12-01
In recent years, environmental concerns over ultra-trace levels of steroid estrogens concentrations in water samples have increased because of their adverse effects on human and animal life. Special attention to the analytical techniques used to quantify steroid estrogens in water samples is therefore increasingly important. The objective of this review was to present an overview of both instrumental and non-instrumental analytical techniques available for the determination of steroid estrogens in water samples, evidencing their respective potential advantages and limitations using the Need, Approach, Benefit, and Competition (NABC) approach. The analytical techniques highlighted in this review were instrumental and non-instrumental analytical techniques namely gas chromatography mass spectrometry (GC-MS), liquid chromatography mass spectrometry (LC-MS), enzyme-linked immuno sorbent assay (ELISA), radio immuno assay (RIA), yeast estrogen screen (YES) assay, and human breast cancer cell line proliferation (E-screen) assay. The complexity of water samples and their low estrogenic concentrations necessitates the use of highly sensitive instrumental analytical techniques (GC-MS and LC-MS) and non-instrumental analytical techniques (ELISA, RIA, YES assay and E-screen assay) to quantify steroid estrogens. Both instrumental and non-instrumental analytical techniques have their own advantages and limitations. However, the non-instrumental ELISA analytical techniques, thanks to its lower detection limit and simplicity, its rapidity and cost-effectiveness, currently appears to be the most reliable for determining steroid estrogens in water samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Experimental design and statistical methods for improved hit detection in high-throughput screening.
Malo, Nathalie; Hanley, James A; Carlile, Graeme; Liu, Jing; Pelletier, Jerry; Thomas, David; Nadon, Robert
2010-09-01
Identification of active compounds in high-throughput screening (HTS) contexts can be substantially improved by applying classical experimental design and statistical inference principles to all phases of HTS studies. The authors present both experimental and simulated data to illustrate how true-positive rates can be maximized without increasing false-positive rates by the following analytical process. First, the use of robust data preprocessing methods reduces unwanted variation by removing row, column, and plate biases. Second, replicate measurements allow estimation of the magnitude of the remaining random error and the use of formal statistical models to benchmark putative hits relative to what is expected by chance. Receiver Operating Characteristic (ROC) analyses revealed superior power for data preprocessed by a trimmed-mean polish method combined with the RVM t-test, particularly for small- to moderate-sized biological hits.
Implementing a method of screening one-well hydraulic barrier design alternatives.
Rubin, Hillel; Shoemaker, Christine A; Köngeter, Jürgen
2009-01-01
This article provides details of applying the method developed by the authors (Rubin et al. 2008b) for screening one-well hydraulic barrier design alternatives. The present article with its supporting information (manual and electronic spreadsheets with a case history example) provides the reader complete details and examples of solving the set of nonlinear equations developed by Rubin et al. (2008b). It allows proper use of the analytical solutions and also depicting the various charts given by Rubin et al. (2008b). The final outputs of the calculations are the required position and the discharge of the pumping well. If the contaminant source is nonaqueous phase liquid (NAPL) entrapped within the aquifer, then the method provides an estimate of the aquifer remediation progress (which is a by-product) due to operating the hydraulic barrier.
Fluorescence-based assay as a new screening tool for toxic chemicals
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-01-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients. PMID:27653274
Fluorescence-based assay as a new screening tool for toxic chemicals.
Moczko, Ewa; Mirkes, Evgeny M; Cáceres, César; Gorban, Alexander N; Piletsky, Sergey
2016-09-22
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Fluorescence-based assay as a new screening tool for toxic chemicals
NASA Astrophysics Data System (ADS)
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-09-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Big data science: A literature review of nursing research exemplars.
Westra, Bonnie L; Sylvia, Martha; Weinfurter, Elizabeth F; Pruinelli, Lisiane; Park, Jung In; Dodd, Dianna; Keenan, Gail M; Senk, Patricia; Richesson, Rachel L; Baukner, Vicki; Cruz, Christopher; Gao, Grace; Whittenburg, Luann; Delaney, Connie W
Big data and cutting-edge analytic methods in nursing research challenge nurse scientists to extend the data sources and analytic methods used for discovering and translating knowledge. The purpose of this study was to identify, analyze, and synthesize exemplars of big data nursing research applied to practice and disseminated in key nursing informatics, general biomedical informatics, and nursing research journals. A literature review of studies published between 2009 and 2015. There were 650 journal articles identified in 17 key nursing informatics, general biomedical informatics, and nursing research journals in the Web of Science database. After screening for inclusion and exclusion criteria, 17 studies published in 18 articles were identified as big data nursing research applied to practice. Nurses clearly are beginning to conduct big data research applied to practice. These studies represent multiple data sources and settings. Although numerous analytic methods were used, the fundamental issue remains to define the types of analyses consistent with big data analytic methods. There are needs to increase the visibility of big data and data science research conducted by nurse scientists, further examine the use of state of the science in data analytics, and continue to expand the availability and use of a variety of scientific, governmental, and industry data resources. A major implication of this literature review is whether nursing faculty and preparation of future scientists (PhD programs) are prepared for big data and data science. Copyright © 2016 Elsevier Inc. All rights reserved.
Noncontact methods for optical testing of convex aspheric mirrors for future large telescopes
NASA Astrophysics Data System (ADS)
Goncharov, Alexander V.; Druzhin, Vladislav V.; Batshev, Vladislav I.
2009-06-01
Non-contact methods for testing of large rotationally symmetric convex aspheric mirrors are proposed. These methods are based on non-null testing with side illumination schemes, in which a narrow collimated beam is reflected from the meridional aspheric profile of a mirror. The figure error of the mirror is deduced from the intensity pattern from the reflected beam obtained on a screen, which is positioned in the tangential plane (containing the optical axis) and perpendicular to the incoming beam. Testing of the entire surface is carried out by rotating the mirror about its optical axis and registering the characteristics of the intensity pattern on the screen. The intensity pattern can be formed using three different techniques: modified Hartman test, interference and boundary curve test. All these techniques are well known but have not been used in the proposed side illumination scheme. Analytical expressions characterizing the shape and location of the intensity pattern on the screen or a CCD have been developed for all types of conic surfaces. The main advantage of these testing methods compared with existing methods (Hindle sphere, null lens, computer generated hologram) is that the reference system does not require large optical components.
Roca, M; Leon, N; Pastor, A; Yusà, V
2014-12-29
In this study we propose an analytical strategy that combines a target approach for the quantitative analysis of contemporary pesticide metabolites with a comprehensive post-target screening for the identification of biomarkers of exposure to environmental contaminants in urine using liquid chromatography coupled to high-resolution mass spectrometry (LC–HRMS). The quantitative method for the target analysis of 29 urinary metabolites of organophosphate (OP) insecticides, synthetic pyrethroids, herbicides and fungicides was validated after a previous statistical optimization of the main factors governing the ion source ionization and a fragmentation study using the high energy collision dissociation (HCD) cell. The full scan accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), in both ESI+ and ESI− modes, and with and without HCD-fragmentation. The method – LOQ was lower than 3.2 μg L−1 for the majority of the analytes. For post-target screening a customized theoretical database was built, for the identification of 60 metabolites including pesticides, PAHs, phenols, and other metabolites of environmental pollutants. For identification purposes, accurate exact mass with less than 5 ppm, and diagnostic ions including isotopes and/or fragments were used. The analytical strategy was applied to 20 urine sample collected from children living in Valencia Region. Eleven target metabolites were detected with concentrations ranging from 1.18 to 131 μg L−1. Likewise, several compounds were tentatively identified in the post-target analysis belonging to the families of phthalates, phenols and parabenes. The proposed strategy is suitable for the determination of target pesticide biomarkers in urine in the framework of biomonitoring studies, and appropriate for the identification of other non-target metabolites.
Stanley, Shawn M R; Foo, Hsiao Ching
2006-05-19
A rapid, selective and robust direct-injection LC/hybrid tandem MS method has been developed for simultaneous screening of more than 250 basic drugs in the supernatant of enzyme hydrolysed equine urine. Analytes, trapped using a short HLB extraction column, are refocused and separated on a Sunfire C(18) analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Independent data acquisition (IDA) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. The decision on whether or not to report a sample as a positive result was based upon both the presence of a MRM response within the correct retention time range and a qualitative match between the EPI spectrum obtained and the corresponding reference standard. Ninety seven percent of the drugs targeted by this method met our detection criteria when spiked into urine at 100 ng/ml; 199 were found at 10 ng/ml, 83 at 1 ng/ml and 4 at 0.1 ng/ml.
Abushareeda, Wadha; Vonaparti, Ariadni; Saad, Khadija Al; Almansoori, Moneera; Meloug, Mbarka; Saleh, Amal; Aguilera, Rodrigo; Angelis, Yiannis; Horvatovich, Peter L; Lommen, Arjen; Alsayrafi, Mohammed; Georgakopoulos, Costas
2018-03-20
The aim of this paper is to present the development and validation of a high-resolution full scan (HR-FS) electrospray ionization (ESI) liquid chromatography coupled to quadrupole Orbitrap mass spectrometer (LC/Q/Orbitrap MS) platform for the screening of prohibited substances in human urine according to World Antidoping Agency (WADA) requirements. The method was also validated for quantitative analysis of six endogenous steroids (epitestosterone, testosterone, 5α-dihydrotestosterone, dehydroepiandrosterone, androsterone and etiocholanolone) in their intact sulfates form. The sample preparation comprised a combination of a hydrolyzed urine liquid-liquid extraction and the dilute & shoot addition of original urine in the extracted aliquot. The HR-FS MS acquisition mode with Polarity Switching was applied in combination of the Quadrupole-Orbitrap mass filter. The HR-FS acquisition of analytical signal, for known and unknown small molecules, allows the inclusion of all analytes detectable with LC-MS for antidoping investigations to identify the use of known or novel prohibited substances and metabolites after electronic data files' reprocessing. The method has been validated to be fit-for-purpose for the antidoping analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Khalili, Azizeh Farshbaf; Shahnazi, Mahnaz
2010-04-01
Breast cancer is the most common cancer and the most common cause of death in Iranian women aged 35-55 years. Breast cancer screening comprises breast self-examination (BSE), clinical breast examination (CBE) and mammography. The study aimed to examine the performance of screening methods among women referring to health centers of Tabriz, Iran. This was a descriptive-analytical research carried out on 400 women aged 20-50 years. The samples were chosen through random multistage sampling among health centers of Tabriz then active records of women. A questionnaire and observational checklist was used to elicit socio-demographic information and performance of women towards breast cancer screening methods. Descriptive and inferential statistics (chi-square and Fisher's exact test) were used to analyze the data. Only 18.8% of women did breast self-examination, 19.1% had clinical breast examination and 3.3% had mammogram. Statistical test showed a significant relationship between performing BSE and educational level, employment, income, number of children, breastfeeding history, breastfeeding quality and family history of breast cancer. There was a significant correlation between performing CBE and history of breast tumor and also, between performing the mammography and family history of breast cancer and history of breast tumor (P < 0.05). The findings showed that the performance of breast cancer screening methods was not satisfactory. Performance in high risk women was very desirable than others. The presentation of imperative education about breast cancer screening methods through health staff especially in pregnancy, post-partum and even in pre marriage counseling periods seems necessary.
Chepyala, Divyabharathi; Tsai, I-Lin; Liao, Hsiao-Wei; Chen, Guan-Yuan; Chao, Hsi-Chun; Kuo, Ching-Hua
2017-03-31
An increased rate of drug abuse is a major social problem worldwide. The dried blood spot (DBS) sampling technique offers many advantages over using urine or whole blood sampling techniques. This study developed a simple and efficient ultra-high-performance liquid chromatography-ion booster-quadrupole time-of-flight mass spectrometry (UHPLC-IB-QTOF-MS) method for the analysis of abused drugs and their metabolites using DBS. Fifty-seven compounds covering the most commonly abused drugs, including amphetamines, opioids, cocaine, benzodiazepines, barbiturates, and many other new and emerging abused drugs, were selected as the target analytes of this study. An 80% acetonitrile solvent with a 5-min extraction by Geno grinder was used for sample extraction. A Poroshell column was used to provide efficient separation, and under optimal conditions, the analytical times were 15 and 5min in positive and negative ionization modes, respectively. Ionization parameters of both electrospray ionization source and ion booster (IB) source containing an extra heated zone were optimized to achieve the best ionization efficiency of the investigated abused drugs. In spite of their structural diversity, most of the abused drugs showed an enhanced mass response with the high temperature ionization from an extra heated zone of IB source. Compared to electrospray ionization, the ion booster (IB) greatly improved the detection sensitivity for 86% of the analytes by 1.5-14-fold and allowed the developed method to detect trace amounts of compounds on the DBS cards. The validation results showed that the coefficients of variation of intra-day and inter-day precision in terms of the signal intensity were lower than 19.65%. The extraction recovery of all analytes was between 67.21 and 115.14%. The limits of detection of all analytes were between 0.2 and 35.7ngmL -1 . The stability study indicated that 7% of compounds showed poor stability (below 50%) on the DBS cards after 6 months of storage at room temperature and -80°C. The reported method provides a new direction for abused drug screening using DBS. Copyright © 2017 Elsevier B.V. All rights reserved.
Ślączka-Wilk, Magdalena M; Włodarczyk, Elżbieta; Kaleniecka, Aleksandra; Zarzycki, Paweł K
2017-07-01
There is increasing interest in the development of simple analytical systems enabling the fast screening of target components in complex samples. A number of newly invented protocols are based on quasi separation techniques involving microfluidic paper-based analytical devices and/or micro total analysis systems. Under such conditions, the quantification of target components can be performed mainly due to selective detection. The main goal of this paper is to demonstrate that miniaturized planar chromatography has the capability to work as an efficient separation and quantification tool for the analysis of multiple targets within complex environmental samples isolated and concentrated using an optimized SPE method. In particular, we analyzed various samples collected from surface water ecosystems (lakes, rivers, and the Baltic Sea of Middle Pomerania in the northern part of Poland) in different seasons, as well as samples collected during key wastewater technological processes (originating from the "Jamno" wastewater treatment plant in Koszalin, Poland). We documented that the multiple detection of chromatographic spots on RP-18W microplates-under visible light, fluorescence, and fluorescence quenching conditions, and using the visualization reagent phosphomolybdic acid-enables fast and robust sample classification. The presented data reveal that the proposed micro-TLC system is useful, inexpensive, and can be considered as a complementary method for the fast control of treated sewage water discharged by a municipal wastewater treatment plant, particularly for the detection of low-molecular mass micropollutants with polarity ranging from estetrol to progesterone, as well as chlorophyll-related dyes. Due to the low consumption of mobile phases composed of water-alcohol binary mixtures (less than 1 mL/run for the simultaneous separation of up to nine samples), this method can be considered an environmentally friendly and green chemistry analytical tool. The described analytical protocol can be complementary to those involving classical column chromatography (HPLC) or various planar microfluidic devices.
Dillon, Roslyn; Croner, Lisa J; Bucci, John; Kairs, Stefanie N; You, Jia; Beasley, Sharon; Blimline, Mark; Carino, Rochele B; Chan, Vicky C; Cuevas, Danissa; Diggs, Jeff; Jennings, Megan; Levy, Jacob; Mina, Ginger; Yee, Alvin; Wilcox, Bruce
2018-05-30
Early detection of colorectal cancer (CRC) is key to reducing associated mortality. Despite the importance of early detection, approximately 40% of individuals in the United States between the ages of 50-75 have never been screened for CRC. The low compliance with colonoscopy and fecal-based screening may be addressed with a non-invasive alternative such as a blood-based test. We describe here the analytical validation of a multiplexed blood-based assay that measures the plasma concentrations of 15 proteins to assess advanced adenoma (AA) and CRC risk in symptomatic patients. The test was developed on an electrochemiluminescent immunoassay platform employing four multi-marker panels, to be implemented in the clinic as a laboratory developed test (LDT). Under the Clinical Laboratory Improvement Amendments (CLIA) and College of American Pathologists (CAP) regulations, a United States-based clinical laboratory utilizing an LDT must establish performance characteristics relating to analytical validity prior to releasing patient test results. This report describes a series of studies demonstrating the precision, accuracy, analytical sensitivity, and analytical specificity for each of the 15 assays, as required by CLIA/CAP. In addition, the report describes studies characterizing each of the assays' dynamic range, parallelism, tolerance to common interfering substances, spike recovery, and stability to sample freeze-thaw cycles. Upon completion of the analytical characterization, a clinical accuracy study was performed to evaluate concordance of AA and CRC classifier model calls using the analytical method intended for use in the clinic. Of 434 symptomatic patient samples tested, the percent agreement with original CRC and AA calls was 87% and 92% respectively. All studies followed CLSI guidelines and met the regulatory requirements for implementation of a new LDT. The results provide the analytical evidence to support the implementation of the novel multi-marker test as a clinical test for evaluating CRC and AA risk in symptomatic individuals. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
McDannell, Kalin T.; Zeitler, Peter K.; Janes, Darwin G.; Idleman, Bruce D.; Fayon, Annia K.
2018-02-01
Old slowly-cooled apatites often yield dispersed (U-Th)/He ages for a variety of reasons, some well understood and some not. Analytical protocols like careful grain selection can reduce the impact of this dispersion but add costs in time and resources and too often have proven insufficient. We assess a new analytical protocol that utilizes static-gas measurement during continuous ramped heating (CRH) as a means to rapidly screen apatite samples. In about the time required for a conventional total-gas analysis, this method can discriminate between samples showing expected volume-diffusion behavior and those showing anomalous release patterns inconsistent with their direct use in thermochronologic applications. This method also appears able to discriminate between the radiogenic and extraneous 4He fractions released by a sample, potentially allowing ages to be corrected. Well-behaved examples such as the Durango standard and other apatites with good age reproducibility show the expected smooth, sigmoidal gas-release curves predicted for volume diffusion using typical apatite kinetics, with complete exhaustion by ∼900 °C for linear heating at 20 °C/min. Secondary factors such as U and Th zoning and alpha-loss distribution have a relatively minor impact on such profiles. In contrast, samples having greater age dispersion show significant He release in the form of outgassing spikes and He release deferred to higher temperatures. Screening results for a range of samples permit us to assess the degree to which CRH screening can identify misbehaving grains, give insight into the source of extraneous He, and suggest that in some cases it may be possible to correct ages for the presence of such components.
Model dielectric function for 2D semiconductors including substrate screening
NASA Astrophysics Data System (ADS)
Trolle, Mads L.; Pedersen, Thomas G.; Véniard, Valerie
2017-01-01
Dielectric screening of excitons in 2D semiconductors is known to be a highly non-local effect, which in reciprocal space translates to a strong dependence on momentum transfer q. We present an analytical model dielectric function, including the full non-linear q-dependency, which may be used as an alternative to more numerically taxing ab initio screening functions. By verifying the good agreement between excitonic optical properties calculated using our model dielectric function, and those derived from ab initio methods, we demonstrate the versatility of this approach. Our test systems include: Monolayer hBN, monolayer MoS2, and the surface exciton of a 2 × 1 reconstructed Si(111) surface. Additionally, using our model, we easily take substrate screening effects into account. Hence, we include also a systematic study of the effects of substrate media on the excitonic optical properties of MoS2 and hBN.
Grohmann, Lutz; Brünen-Nieweler, Claudia; Nemeth, Anne; Waiblinger, Hans-Ulrich
2009-10-14
Polymerase Chain Reaction (PCR)-based screening methods targeting genetic elements commonly used in genetically modified (GM) plants are important tools for the detection of GM materials in food, feed, and seed samples. To expand and harmonize the screening capability of enforcement laboratories, the German Federal Office of Consumer Protection and Food Safety conducted collaborative trials for interlaboratory validation of real-time PCR methods for detection of the phosphinothricin acetyltransferase (bar) gene from Streptomyces hygroscopicus and a construct containing the 5-enolpyruvylshikimate-3-phosphate synthase gene from Agrobacterium tumefaciens sp. strain CP4 (ctp2-cp4epsps), respectively. To assess the limit of detection, precision, and accuracy of the methods, laboratories had to analyze two sets of 18 coded genomic DNA samples of events LLRice62 and MS8 with the bar method and NK603 and GT73 with the ctp2-cp4epsps method at analyte levels of 0, 0.02, and 0.1% GM content, respectively. In addition, standard DNAs were provided to the laboratories to generate calibration curves for copy number quantification of the bar and ctp2-cp4epsps target sequences present in the test samples. The study design and the results obtained are discussed with respect to the difficult issue of developing general guidelines and concepts for the collaborative trial validation of qualitative PCR screening methods.
Budnik, Lygia T; Fahrenholtz, Svea; Kloth, Stefan; Baur, Xaver
2010-04-01
Protection against infestation of a container cargo by alien species is achieved by mandatory fumigation with pesticides. Most of the effective fumigants are methyl and ethyl halide gases that are highly toxic and are a risk to both human health and the environment. There is a worldwide need for a reliable and robust analytical screening procedure for these volatile chemicals in a multitude of health and environmental scenarios. We have established a highly sensitive broad spectrum mass spectrometry method combined with thermal desorption gas chromatography to detect, identify and quantify volatile pesticide residues. Using this method, 1201 random ambient air samples taken from freight containers arriving at the biggest European ports of Hamburg and Rotterdam were analyzed over a period of two and a half years. This analytical procedure is a valuable strategy to measure air pollution from these hazardous chemicals, to help in the identification of pesticides in the new mixtures/formulations that are being adopted globally and to analyze expired breath samples after suspected intoxication in biomonitoring.
Peng, Tianyuan; Wooke, Zachary; Pohl, Nicola L B
2018-03-22
Acidic hydrolysis is commonly used as a first step to break down oligo- and polysaccharides into monosaccharide units for structural analysis. While easy to set up and amenable to mass spectrometry detection, acid hydrolysis is not without its drawbacks. For example, ring-destruction side reactions and degradation products, along with difficulties in optimizing conditions from analyte to analyte, greatly limits its broad utility. Herein we report studies on a hydrogen peroxide/CuGGH metallopeptide-based glycosidase mimetic design for a more efficient and controllable carbohydrate hydrolysis. A library of methyl glycosides consisting of ten common monosaccharide substrates, along with oligosaccharide substrates, was screened with the artificial glycosidase for hydrolytic activity in a high-throughput format with a robotic liquid handling system. The artificial glycosidase was found to be active towards most screened linkages, including alpha- and beta-anomers, thus serving as a potential alternative method for traditional acidic hydrolysis approaches of oligosaccharides. Copyright © 2018 Elsevier Ltd. All rights reserved.
New solutions to the constant-head test performed at a partially penetrating well
NASA Astrophysics Data System (ADS)
Chang, Y. C.; Yeh, H. D.
2009-05-01
SummaryThe mathematical model describing the aquifer response to a constant-head test performed at a fully penetrating well can be easily solved by the conventional integral transform technique. In addition, the Dirichlet-type condition should be chosen as the boundary condition along the rim of wellbore for such a test well. However, the boundary condition for a test well with partial penetration must be considered as a mixed-type condition. Generally, the Dirichlet condition is prescribed along the well screen and the Neumann type no-flow condition is specified over the unscreened part of the test well. The model for such a mixed boundary problem in a confined aquifer system of infinite radial extent and finite vertical extent is solved by the dual series equations and perturbation method. This approach provides analytical results for the drawdown in the partially penetrating well and the well discharge along the screen. The semi-analytical solutions are particularly useful for the practical applications from the computational point of view.
Decision Support System for Determining Scholarship Selection using an Analytical Hierarchy Process
NASA Astrophysics Data System (ADS)
Puspitasari, T. D.; Sari, E. O.; Destarianto, P.; Riskiawan, H. Y.
2018-01-01
Decision Support System is a computer program application that analyzes data and presents it so that users can make decision more easily. Determining Scholarship Selection study case in Senior High School in east Java wasn’t easy. It needed application to solve the problem, to improve the accuracy of targets for prospective beneficiaries of poor students and to speed up the screening process. This research will build system uses the method of Analytical Hierarchy Process (AHP) is a method that solves a complex and unstructured problem into its group, organizes the groups into a hierarchical order, inputs numerical values instead of human perception in comparing relative and ultimately with a synthesis determined elements that have the highest priority. The accuracy system for this research is 90%.
Analysis of multiple mycotoxins in food.
Hajslova, Jana; Zachariasova, Milena; Cajka, Tomas
2011-01-01
Mycotoxins are secondary metabolites of microscopic filamentous fungi. With regard to the widespread distribution of fungi in the environment, mycotoxins are considered to be one of the most important natural contaminants in foods and feeds. To protect consumers' health and reduce economic losses, surveillance and control of mycotoxins in food and feed has become a major objective for producers, regulatory authorities, and researchers worldwide. In this context, availability of reliable analytical methods applicable for this purpose is essential. Since the variety of chemical structures of mycotoxins makes impossible to use one single technique for their analysis, a vast number of analytical methods has been developed and validated. Both a large variability of food matrices and growing demands for a fast, cost-saving and accurate determination of multiple mycotoxins by a single method outline new challenges for analytical research. This strong effort is facilitated by technical developments in mass spectrometry allowing decreasing the influence of matrix effects in spite of omitting sample clean-up step. The current state-of-the-art together with future trends is presented in this chapter. Attention is focused mainly on instrumental method; advances in biosensors and other screening bioanalytical approaches enabling analysis of multiple mycotoxins are not discussed in detail.
Designing Studies That Would Address the Multilayered Nature of Health Care
Pennell, Michael; Rhoda, Dale; Hade, Erinn M.; Paskett, Electra D.
2010-01-01
We review design and analytic methods available for multilevel interventions in cancer research with particular attention to study design, sample size requirements, and potential to provide statistical evidence for causal inference. The most appropriate methods will depend on the stage of development of the research and whether randomization is possible. Early on, fractional factorial designs may be used to screen intervention components, particularly when randomization of individuals is possible. Quasi-experimental designs, including time-series and multiple baseline designs, can be useful once the intervention is designed because they require few sites and can provide the preliminary evidence to plan efficacy studies. In efficacy and effectiveness studies, group-randomized trials are preferred when randomization is possible and regression discontinuity designs are preferred otherwise if assignment based on a quantitative score is possible. Quasi-experimental designs may be used, especially when combined with recent developments in analytic methods to reduce bias in effect estimates. PMID:20386057
Cembrowski, G S; Hackney, J R; Carey, N
1993-04-01
The Clinical Laboratory Improvement Act of 1988 (CLIA 88) has dramatically changed proficiency testing (PT) practices having mandated (1) satisfactory PT for certain analytes as a condition of laboratory operation, (2) fixed PT limits for many of these "regulated" analytes, and (3) an increased number of PT specimens (n = 5) for each testing cycle. For many of these analytes, the fixed limits are much broader than the previously employed Standard Deviation Index (SDI) criteria. Paradoxically, there may be less incentive to identify and evaluate analytically significant outliers to improve the analytical process. Previously described "control rules" to evaluate these PT results are unworkable as they consider only two or three results. We used Monte Carlo simulations of Kodak Ektachem analyzers participating in PT to determine optimal control rules for the identification of PT results that are inconsistent with those from other laboratories using the same methods. The analysis of three representative analytes, potassium, creatine kinase, and iron was simulated with varying intrainstrument and interinstrument standard deviations (si and sg, respectively) obtained from the College of American Pathologists (Northfield, Ill) Quality Assurance Services data and Proficiency Test data, respectively. Analytical errors were simulated in each of the analytes and evaluated in terms of multiples of the interlaboratory SDI. Simple control rules for detecting systematic and random error were evaluated with power function graphs, graphs of probability of error detected vs magnitude of error. Based on the simulation results, we recommend screening all analytes for the occurrence of two or more observations exceeding the same +/- 1 SDI limit. For any analyte satisfying this condition, the mean of the observations should be calculated. For analytes with sg/si ratios between 1.0 and 1.5, a significant systematic error is signaled by the mean exceeding 1.0 SDI. Significant random error is signaled by one observation exceeding the +/- 3-SDI limit or the range of the observations exceeding 4 SDIs. For analytes with higher sg/si, significant systematic or random error is signaled by violation of the screening rule (having at least two observations exceeding the same +/- 1 SDI limit). Random error can also be signaled by one observation exceeding the +/- 1.5-SDI limit or the range of the observations exceeding 3 SDIs. We present a practical approach to the workup of apparent PT errors.
Reiman, Anne; Pandey, Sarojini; Lloyd, Kate L; Dyer, Nigel; Khan, Mike; Crockard, Martin; Latten, Mark J; Watson, Tracey L; Cree, Ian A; Grammatopoulos, Dimitris K
2016-11-01
Background Detection of disease-associated mutations in patients with familial hypercholesterolaemia is crucial for early interventions to reduce risk of cardiovascular disease. Screening for these mutations represents a methodological challenge since more than 1200 different causal mutations in the low-density lipoprotein receptor has been identified. A number of methodological approaches have been developed for screening by clinical diagnostic laboratories. Methods Using primers targeting, the low-density lipoprotein receptor, apolipoprotein B, and proprotein convertase subtilisin/kexin type 9, we developed a novel Ion Torrent-based targeted re-sequencing method. We validated this in a West Midlands-UK small cohort of 58 patients screened in parallel with other mutation-targeting methods, such as multiplex polymerase chain reaction (Elucigene FH20), oligonucleotide arrays (Randox familial hypercholesterolaemia array) or the Illumina next-generation sequencing platform. Results In this small cohort, the next-generation sequencing method achieved excellent analytical performance characteristics and showed 100% and 89% concordance with the Randox array and the Elucigene FH20 assay. Investigation of the discrepant results identified two cases of mutation misclassification of the Elucigene FH20 multiplex polymerase chain reaction assay. A number of novel mutations not previously reported were also identified by the next-generation sequencing method. Conclusions Ion Torrent-based next-generation sequencing can deliver a suitable alternative for the molecular investigation of familial hypercholesterolaemia patients, especially when comprehensive mutation screening for rare or unknown mutations is required.
Comparison of analytical methods for the determination of histamine in reference canned fish samples
NASA Astrophysics Data System (ADS)
Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.
2017-09-01
Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.
Web-Based Newborn Screening System for Metabolic Diseases: Machine Learning Versus Clinicians
Chen, Wei-Hsin; Hsu, Kai-Ping; Chen, Han-Ping; Su, Xing-Yu; Tseng, Yi-Ju; Chien, Yin-Hsiu; Hwu, Wuh-Liang; Lai, Feipei
2013-01-01
Background A hospital information system (HIS) that integrates screening data and interpretation of the data is routinely requested by hospitals and parents. However, the accuracy of disease classification may be low because of the disease characteristics and the analytes used for classification. Objective The objective of this study is to describe a system that enhanced the neonatal screening system of the Newborn Screening Center at the National Taiwan University Hospital. The system was designed and deployed according to a service-oriented architecture (SOA) framework under the Web services .NET environment. The system consists of sample collection, testing, diagnosis, evaluation, treatment, and follow-up services among collaborating hospitals. To improve the accuracy of newborn screening, machine learning and optimal feature selection mechanisms were investigated for screening newborns for inborn errors of metabolism. Methods The framework of the Newborn Screening Hospital Information System (NSHIS) used the embedded Health Level Seven (HL7) standards for data exchanges among heterogeneous platforms integrated by Web services in the C# language. In this study, machine learning classification was used to predict phenylketonuria (PKU), hypermethioninemia, and 3-methylcrotonyl-CoA-carboxylase (3-MCC) deficiency. The classification methods used 347,312 newborn dried blood samples collected at the Center between 2006 and 2011. Of these, 220 newborns had values over the diagnostic cutoffs (positive cases) and 1557 had values that were over the screening cutoffs but did not meet the diagnostic cutoffs (suspected cases). The original 35 analytes and the manifested features were ranked based on F score, then combinations of the top 20 ranked features were selected as input features to support vector machine (SVM) classifiers to obtain optimal feature sets. These feature sets were tested using 5-fold cross-validation and optimal models were generated. The datasets collected in year 2011 were used as predicting cases. Results The feature selection strategies were implemented and the optimal markers for PKU, hypermethioninemia, and 3-MCC deficiency were obtained. The results of the machine learning approach were compared with the cutoff scheme. The number of the false positive cases were reduced from 21 to 2 for PKU, from 30 to 10 for hypermethioninemia, and 209 to 46 for 3-MCC deficiency. Conclusions This SOA Web service–based newborn screening system can accelerate screening procedures effectively and efficiently. An SVM learning methodology for PKU, hypermethioninemia, and 3-MCC deficiency metabolic diseases classification, including optimal feature selection strategies, is presented. By adopting the results of this study, the number of suspected cases could be reduced dramatically. PMID:23702487
Moore, Katherine N; Garvin, Demetra; Thomas, Brian F; Grabenauer, Megan
2017-09-01
Synthetic cannabinoids are sprayed onto plant material and smoked for their marijuana-like effects. Clandestine manufacturers modify synthetic cannabinoid structures by creating closely related analogs. Forensic laboratories are tasked with detection of these analog compounds, but targeted analytical methods are often thwarted by the structural modifications. Here, direct analysis in real time coupled to accurate mass time-of-flight mass spectrometry (DART-TOF-MS) in combination with liquid chromatography quadruple time-of-flight mass spectrometry (LC-QTOF-MS) are presented as a screening and nontargeted confirmation method, respectively. Methanol extracts of herbal material were run using both methods. Spectral data from four different herbal products were evaluated by comparing fragmentation pattern, accurate mass and retention time to available reference standards. JWH-018, JWH-019, AM2201, JWH-122, 5F-AKB48, AKB48-N-(4-pentenyl) analog, UR144, and XLR11 were identified in the products. Results demonstrate that DART-TOF-MS affords a useful approach for rapid screening of herbal products for the presence and identification of synthetic cannabinoids. © 2017 American Academy of Forensic Sciences.
Serpe, F P; Russo, R; Ambrosio, L; Esposito, M; Severino, L
2013-06-01
European Commission Regulation 882/2004/EC requires that official control laboratories for foodstuffs in the member states are certified according to UNI EN ISO/IEC 17025:2005 (general requirement for the competence of calibration and testing laboratories). This mandatory requirement has resulted in a continuous adaptation and development of analytical procedures. The aim of this study was to develop a method for semiquantitative screening of polychlorinated biphenyls in fish for human consumption. According to the Commission Decision 657/2002/CE, the detection capability, the precision, the selectivity-specificity, and applicability-ruggedness-stability were determined to validate the method. Moreover, trueness was verified. This procedure resulted in rapid execution, which allowed immediate and effective intervention by the local health authorities to protect the health of consumers. Finally, the procedure has been recognized by the Italian accrediting body, ACCREDIA.
Geyer, Pierre M; Hulme, Matthew C; Irving, Joseph P B; Thompson, Paul D; Ashton, Ryan N; Lee, Robert J; Johnson, Lucy; Marron, Jack; Banks, Craig E; Sutcliffe, Oliver B
2016-11-01
The prevalence of new psychoactive substances (NPSs) in forensic casework has increased prominently in recent years. This has given rise to significant legal and analytical challenges in the identification of these substances. The requirement for validated, robust and rapid testing methodologies for these compounds is obvious. This study details the analysis of 13 synthesised diphenidine derivatives encountered in casework using presumptive testing, thin layer chromatography and gas chromatography-mass spectrometry (GC-MS). Specifically, the validated GC-MS method provides, for the first time, both a general screening method and quantification of the active components for seized solid samples, both in their pure form and in the presence of common adulterants. Graphical Abstract Chemical synthesis and forensic analysis of 13 diphenidine-derived new psychoactive substance(s).
Maes, Jan; Siverio-Mota, Dany; Marcourt, Laurence; Munck, Sebastian; Kamuhabwa, Appolinary R.; Moshi, Mainen J.; Esguerra, Camila V.; de Witte, Peter A. M.; Crawford, Alexander D.; Wolfender, Jean-Luc
2013-01-01
Natural products (NPs) are an attractive source of chemical diversity for small-molecule drug discovery. Several challenges nevertheless persist with respect to NP discovery, including the time and effort required for bioassay-guided isolation of bioactive NPs, and the limited biomedical relevance to date of in vitro bioassays used in this context. With regard to bioassays, zebrafish have recently emerged as an effective model system for chemical biology, allowing in vivo high-content screens that are compatible with microgram amounts of compound. For the deconvolution of the complex extracts into their individual constituents, recent progress has been achieved on several fronts as analytical techniques now enable the rapid microfractionation of extracts, and microflow NMR methods have developed to the point of allowing the identification of microgram amounts of NPs. Here we combine advanced analytical methods with high-content screening in zebrafish to create an integrated platform for microgram-scale, in vivo NP discovery. We use this platform for the bioassay-guided fractionation of an East African medicinal plant, Rhynchosia viscosa, resulting in the identification of both known and novel isoflavone derivatives with anti-angiogenic and anti-inflammatory activity. Quantitative microflow NMR is used both to determine the structure of bioactive compounds and to quantify them for direct dose-response experiments at the microgram scale. The key advantages of this approach are (1) the microgram scale at which both biological and analytical experiments can be performed, (2) the speed and the rationality of the bioassay-guided fractionation – generic for NP extracts of diverse origin – that requires only limited sample-specific optimization and (3) the use of microflow NMR for quantification, enabling the identification and dose-response experiments with only tens of micrograms of each compound. This study demonstrates that a complete in vivo bioassay-guided fractionation can be performed with only 20 mg of NP extract within a few days. PMID:23700445
Polymeric assay film for direct colorimetric detection
Charych, Deborah; Nagy, Jon; Spevak, Wayne
2002-01-01
A lipid bilayer with affinity to an analyte, which directly signals binding by a changes in the light absorption spectra. This novel assay means and method has special applications in the drug development and medical testing fields. Using a spectrometer, the system is easily automated, and a multiple well embodiment allows inexpensive screening and sequential testing. This invention also has applications in industry for feedstock and effluent monitoring.
Polymeric assay film for direct colorimetric detection
Charych, Deborah; Nagy, Jon; Spevak, Wayne
1999-01-01
A lipid bilayer with affinity to an analyte, which directly signals binding by a changes in the light absorption spectra. This novel assay means and method has special applications in the drug development and medical testing fields. Using a spectrometer, the system is easily automated, and a multiple well embodiment allows inexpensive screening and sequential testing. This invention also has applications in industry for feedstock and effluent monitoring.
Du, Bowen; Lofton, Jonathan M; Peter, Katherine T; Gipe, Alexander D; James, C Andrew; McIntyre, Jenifer K; Scholz, Nathaniel L; Baker, Joel E; Kolodziej, Edward P
2017-09-20
Untreated urban stormwater runoff contributes to poor water quality in receiving waters. The ability to identify toxicants and other bioactive molecules responsible for observed adverse effects in a complex mixture of contaminants is critical to effective protection of ecosystem and human health, yet this is a challenging analytical task. The objective of this study was to develop analytical methods using liquid chromatography coupled to high-resolution quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) to detect organic contaminants in highway runoff and in runoff-exposed fish (adult coho salmon, Oncorhynchus kisutch). Processing of paired water and tissue samples facilitated contaminant prioritization and aided investigation of chemical bioavailability and uptake processes. Simple, minimal processing effort solid phase extraction (SPE) and elution procedures were optimized for water samples, and selective pressurized liquid extraction (SPLE) procedures were optimized for fish tissues. Extraction methods were compared by detection of non-target features and target compounds (e.g., quantity and peak area), while minimizing matrix interferences. Suspect screening techniques utilized in-house and commercial databases to prioritize high-risk detections for subsequent MS/MS characterization and identification efforts. Presumptive annotations were also screened with an in-house linear regression (log K ow vs. retention time) to exclude isobaric compounds. Examples of confirmed identifications (via reference standard comparison) in highway runoff include ethoprophos, prometon, DEET, caffeine, cotinine, 4(or 5)-methyl-1H-methylbenzotriazole, and acetanilide. Acetanilide was also detected in runoff-exposed fish gill and liver samples. Further characterization of highway runoff and fish tissues (14 and 19 compounds, respectively with tentative identification by MS/MS data) suggests that many novel or poorly characterized organic contaminants exist in urban stormwater runoff and exposed biota.
Jia, Wei; Ling, Yun; Lin, Yuanhui; Chang, James; Chu, Xiaogang
2014-04-04
A new method combining QuEChERS with ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap) was developed for the highly accurate and sensitive screening of 43 antioxidants, preservatives and synthetic sweeteners in dairy products. Response surface methodology was employed to optimize a quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation method for the determination of 42 different analytes in dairy products for the first time. After optimization, the maximum predicted recovery was 99.33% rate for aspartame under the optimized conditions of 10 mL acetionitrile, 1.52 g sodium acetate, 410 mg PSA and 404 mgC18. For the matrices studied, the recovery rates of the other 42 compounds ranged from 89.4% to 108.2%, with coefficient of variation <6.4%. UHPLC/ESI Q-Orbitrap Mass full scan mode acquired full MS data was used to identify and quantify additives, and data-dependent scan mode obtained fragment ion spectra for confirmation. The mass accuracy typically obtained is routinely better than 1.5ppm, and only need to calibrate once a week. The 43 compounds behave dynamic in the range 0.001-1000 μg kg(-1) concentration, with correlation coefficient >0.999. The limits of detection for the analytes are in the range 0.0001-3.6 μg kg(-1). This method has been successfully applied on screening of antioxidants, preservatives and synthetic sweeteners in commercial dairy product samples, and it is very useful for fast screening of different food additives. Copyright © 2014 Elsevier B.V. All rights reserved.
Meta-analytic framework for liquid association.
Wang, Lin; Liu, Silvia; Ding, Ying; Yuan, Shin-Sheng; Ho, Yen-Yi; Tseng, George C
2017-07-15
Although coexpression analysis via pair-wise expression correlation is popularly used to elucidate gene-gene interactions at the whole-genome scale, many complicated multi-gene regulations require more advanced detection methods. Liquid association (LA) is a powerful tool to detect the dynamic correlation of two gene variables depending on the expression level of a third variable (LA scouting gene). LA detection from single transcriptomic study, however, is often unstable and not generalizable due to cohort bias, biological variation and limited sample size. With the rapid development of microarray and NGS technology, LA analysis combining multiple gene expression studies can provide more accurate and stable results. In this article, we proposed two meta-analytic approaches for LA analysis (MetaLA and MetaMLA) to combine multiple transcriptomic studies. To compensate demanding computing, we also proposed a two-step fast screening algorithm for more efficient genome-wide screening: bootstrap filtering and sign filtering. We applied the methods to five Saccharomyces cerevisiae datasets related to environmental changes. The fast screening algorithm reduced 98% of running time. When compared with single study analysis, MetaLA and MetaMLA provided stronger detection signal and more consistent and stable results. The top triplets are highly enriched in fundamental biological processes related to environmental changes. Our method can help biologists understand underlying regulatory mechanisms under different environmental exposure or disease states. A MetaLA R package, data and code for this article are available at http://tsenglab.biostat.pitt.edu/software.htm. ctseng@pitt.edu. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Pelição, Fabrício Souza; Peres, Mariana Dadalto; Pissinate, Jauber Fornaciari; De Martinis, Bruno Spinosa
2014-01-01
A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification in postmortem whole blood samples of cocaine (COC), amphetamines (AMPs) and cannabis; the main drugs involved in cases of impaired driving in Brazil. The analytes were extracted by solid-phase extraction by means of Bond-Elute Certify cartridges, derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide at 80°C for 30 min and analyzed by GC-MS. Linearity ranged from 10 to 500 ng/mL, except for ecgonine methyl ester, for which linearity ranged from 10 to 100 ng/mL. Inter- and intra-day imprecision ranged from 2.8 to 18.4% and from 1.5 to 14.9%, respectively. Accuracy values lay between 86.9 and 104.4%. The limit of quantitation for all drugs was 10 ng/mL and recoveries were >74% for all analytes, except for cannabinoids, which showed poor recovery (∼30%). The developed method was applied to real samples collected from deceased victims due to traffic accidents. These samples were selected according to the results obtained in immunoassay screening on collected urine samples. Five samples were positive for the presence of COC and metabolites, four samples were positive for cannabinoids, six samples were positive for AMPs and two samples were drug negative. Some samples were positive for more than one class of drug. Results obtained from whole blood samples showed good agreement with urine screening. The developed method proved capable of quantifying all three classes of drugs of abuse proposed in this study, through a one-step extraction procedure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Suedee, Roongnapa; Intakong, Wimon; Dickert, Franz L
2006-08-15
An alternative screening method for haloacetic acids (HAAs) disinfection by-products in drinking water is described. The method is based on the use of piezoelectric quartz crystal microbalance (QCM) transducing system, where the electrode is coated with a trichloacetic acid-molecularly imprinted polymer (TCAA-MIP). This MIP comprises a crosslinked poly(ethyleneglycoldimethacrylate-co-4-vinylpyridine). The coated QCM is able to specifically detect the analytes in water samples in terms of the mass change in relation to acid-base interactions of the analytes with the MIP. The TCAA-MIP coated QCM showed high specificity for the determination of TCAA in aqueous solutions containing inorganic anions, but its sensitivity reduced in water samples containing hydrochloric acid due to a mass loss at the sensor surface. Cross-reactivity studies with HAA analogs (dichloro-, monochloro-, tribromo-, dibromo-, and monobromo-acetic acids) and non-structurally related TCAA molecules (acetic acid and malonic acid) indicated that recognition of the structurally related TCAA compounds by the TCAA-MIP-based QCM is due to a carboxylic acid functional group, and probably involves a combination of both size and shape selectivity. The total response time of sensor is in the order of 10min. The achieved limits of detection for HAAs (20-50mugl(-1)) are at present higher than the actual concentrations found in real-life samples, but below the guidelines for the maximum permissible levels (60mugl(-1) for mixed HAAs). Recovery studies with drinking water samples spiked with TCAA or spiked with mixtures of HAAs revealed the reproducibility and precision of the method. The present work has demonstrated that the proposed assay can be a fast, reliable and inexpensive screening method for HAA contaminants in water samples, but further refinement is required to improve the limits of detection.
Muehlwald, S; Buchner, N; Kroh, L W
2018-03-23
Because of the high number of possible pesticide residues and their chemical complexity, it is necessary to develop methods which cover a broad range of pesticides. In this work, a qualitative multi-screening method for pesticides was developed by use of HPLC-ESI-Q-TOF. 110 pesticides were chosen for the creation of a personal compound database and library (PCDL). The MassHunter Qualitative Analysis software from Agilent Technologies was used to identify the analytes. The software parameter settings were optimised to produce a low number of false positive as well as false negative results. The method was validated for 78 selected pesticides. However, the validation criteria were not fulfilled for 45 analytes. Due to this result, investigations were started to elucidate reasons for the low detectability. It could be demonstrated that the three main causes of the signal suppression were the co-eluting matrix (matrix effect), the low sensitivity of the analyte in standard solution and the fragmentation of the analyte in the ion source (in-source collision-induced dissociation). In this paper different examples are discussed showing that the impact of these three causes is different for each analyte. For example, it is possible that an analyte with low signal intensity and an intense fragmentation in the ion source is detectable in a difficult matrix, whereas an analyte with a high sensitivity and a low fragmentation is not detectable in a simple matrix. Additionally, it could be shown that in-source fragments are a helpful tool for an unambiguous identification. Copyright © 2018 Elsevier B.V. All rights reserved.
PCR technology for screening and quantification of genetically modified organisms (GMOs).
Holst-Jensen, Arne; Rønning, Sissel B; Løvseth, Astrid; Berdal, Knut G
2003-04-01
Although PCR technology has obvious limitations, the potentially high degree of sensitivity and specificity explains why it has been the first choice of most analytical laboratories interested in detection of genetically modified (GM) organisms (GMOs) and derived materials. Because the products that laboratories receive for analysis are often processed and refined, the quality and quantity of target analyte (e.g. protein or DNA) frequently challenges the sensitivity of any detection method. Among the currently available methods, PCR methods are generally accepted as the most sensitive and reliable methods for detection of GM-derived material in routine applications. The choice of target sequence motif is the single most important factor controlling the specificity of the PCR method. The target sequence is normally a part of the modified gene construct, for example a promoter, a terminator, a gene, or a junction between two of these elements. However, the elements may originate from wildtype organisms, they may be present in more than one GMO, and their copy number may also vary from one GMO to another. They may even be combined in a similar way in more than one GMO. Thus, the choice of method should fit the purpose. Recent developments include event-specific methods, particularly useful for identification and quantification of GM content. Thresholds for labelling are now in place in many countries including those in the European Union. The success of the labelling schemes is dependent upon the efficiency with which GM-derived material can be detected. We will present an overview of currently available PCR methods for screening and quantification of GM-derived DNA, and discuss their applicability and limitations. In addition, we will discuss some of the major challenges related to determination of the limits of detection (LOD) and quantification (LOQ), and to validation of methods.
Herzog, Bastian; Lemmer, Hilde; Horn, Harald; Müller, Elisabeth
2014-02-22
Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. In laboratory setups, xenobiotics concentrations above 1.0 mg L(-1) without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum.
Li, Miao; Wang, Sicen; He, Langchong
2015-01-01
Natural products (NPs) are important sources of lead compounds in modern drug discovery. To facilitate the screening of volatile active compounds in NPs, we have developed a new biochromatography method that uses rat vascular smooth muscle cells (VSMC), which are rich in L-type calcium channels (LCC), to prepare the stationary phase. This integrated method, which couples cell membrane chromatography (CMC) with gas chromatography-mass spectrometry (GC-MS) via microextraction by packed sorbent (MEPS) technology, has been termed VSMC/CMC-MEPS-GC-MS. Methodological validation confirmed its specificity, reliability and convenience. Screening results for Radix Angelicae Dahuricae and Fructus Cnidii obtained using VSMC/CMC-MEPS-GC-MS were consistent with those obtained using VSMC/CMC-offline-GC-MS. MEPS connection plays as simplified solid-phase extraction and replaces the uncontrollable evaporation operation in reported offline connections, so our new method is supposed to be more efficient and reliable than the offline ones, especially for compounds that are volatile, thermally unstable or difficult to purify. In application, senkyunolide A and ligustilide were preliminary identified as the volatile active components in Rhizoma Chuanxiong. We have thus confirmed the suitability of VSMC/CMC-MEPS-GC-MS for volatile active compounds screening in NP. Copyright © 2014 Elsevier B.V. All rights reserved.
2014-01-01
Background Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. Results The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. Conclusions In laboratory setups, xenobiotics concentrations above 1.0 mg L-1 without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum. PMID:24558966
Hetrick, Evan M; Kramer, Timothy T; Risley, Donald S
2017-03-17
Based on a column-screening exercise, a column ranking system was developed for sample mixtures containing any combination of 26 sugar and sugar alcohol analytes using 16 polar stationary phases in the HILIC mode with acetonitrile/water or acetone/water mobile phases. Each analyte was evaluated on the HILIC columns with gradient elution and the subsequent chromatography data was compiled into a statistical software package where any subset of the analytes can be selected and the columns are then ranked by the greatest separation. Since these analytes lack chromophores, aerosol-based detectors, including an evaporative light scattering detector (ELSD) and a charged aerosol detector (CAD) were employed for qualitative and quantitative detection. Example qualitative applications are provided to illustrate the practicality and efficiency of this HILIC column ranking. Furthermore, the design-space approach was used as a starting point for a quantitative method for the trace analysis of glucose in trehalose samples in a complex matrix. Knowledge gained from evaluating the design-space led to rapid development of a capable method as demonstrated through validation of the following parameters: specificity, accuracy, precision, linearity, limit of quantitation, limit of detection, and range. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of Biomonitoring Data from the CDC National ...
BACKGROUND: Biomonitoring data reported in the National Report on Human Exposure to Environmental Chemicals (NER) provide information on the presence and concentrations of more than 400 chemicals in human blood and urine. Biomonitoring Equivalents (BEs) and other risk assessment-based values now allow interpretation of these biomonitoring data in a public health risk context. OBJECTIVES: Compare the measured biomarker concentrations in the NER with BEs and similar risk assessment values to provide an across-chemical risk assessment perspective on the measured levels for approximately 130 analytes in the NER. METHODS: Available risk assessment-based biomarker screening values, including BEs and Human Biomonitoring-I (HBM-I) values from the German Human Biomonitoring Commission, were identified. Geometric mean and 95th percentile population biomarker concentrations from the NER were compared to the available screening values to generate chemical-specific hazard quotients (HQ) or cancer risk estimates. CONCLUSIONS: Several analytes in the NER approach or exceed HQ values of 1 or cancer risks greater than 1x 10-4 at the geometric mean or 95th percentile, suggesting exposure levels exceed what is considered safe in a large fraction of the population. Analytes of concern include acrylamide, dioxin-like chemicals, benzene, xylene, several metals, di-2(ethylhexyl)phthalate, and some legacy organochlorine pesticides. This analysis provides for the first time a mean
The Cost-Effectiveness of School-Based Eating Disorder Screening
Austin, S. Bryn; LeAnn Noh, H.; Jiang, Yushan; Sonneville, Kendrin R.
2014-01-01
Objectives. We aimed to assess the value of school-based eating disorder (ED) screening for a hypothetical cohort of US public school students. Methods. We used a decision-analytic microsimulation model to model the effectiveness (life-years with ED and quality-adjusted life-years [QALYs]), total direct costs, and cost-effectiveness (cost per QALY gained) of screening relative to current practice. Results. The screening strategy cost $2260 (95% confidence interval [CI] = $1892, $2668) per student and resulted in a per capita gain of 0.25 fewer life-years with ED (95% CI = 0.21, 0.30) and 0.04 QALYs (95% CI = 0.03, 0.05) relative to current practice. The base case cost-effectiveness of the intervention was $9041 per life-year with ED avoided (95% CI = $6617, $12 344) and $56 500 per QALY gained (95% CI = $38 805, $71 250). Conclusions. At willingness-to-pay thresholds of $50 000 and $100 000 per QALY gained, school-based ED screening is 41% and 100% likely to be cost-effective, respectively. The cost-effectiveness of ED screening is comparable to many other accepted pediatric health interventions, including hypertension screening. PMID:25033131
Dettmer, K; Hanna, D; Whetstone, P; Hansen, R; Hammock, B D
2007-08-01
Autism is a complex neurodevelopmental disorder with unknown etiology. One hypothesis regarding etiology in autism is the "opioid peptide excess" theory that postulates that excessive amounts of exogenous opioid-like peptides derived from dietary proteins are detectable in urine and that these compounds may be pathophysiologically important in autism. A selective LC-MS/MS method was developed to analyze gliadinomorphin, beta-casomorphin, deltorphin 1, and deltorphin 2 in urine. The method is based on on-line SPE extraction of the neuropeptides from urine, column switching, and subsequent HPLC analysis. A limit of detection of 0.25 ng/mL was achieved for all analytes. Analyte recovery rates from urine ranged between 78% and 94%, with relative standard deviations of 0.2-6.8%. The method was used to screen 69 urine samples from children with and without autism spectrum disorders for the occurrence of neuropeptides. The target neuropeptides were not detected above the detection limit in either sample set.
Hunt, R.J.; Anderson, M.P.; Kelson, V.A.
1998-01-01
This paper demonstrates that analytic element models have potential as powerful screening tools that can facilitate or improve calibration of more complicated finite-difference and finite-element models. We demonstrate how a two-dimensional analytic element model was used to identify errors in a complex three-dimensional finite-difference model caused by incorrect specification of boundary conditions. An improved finite-difference model was developed using boundary conditions developed from a far-field analytic element model. Calibration of a revised finite-difference model was achieved using fewer zones of hydraulic conductivity and lake bed conductance than the original finite-difference model. Calibration statistics were also improved in that simulated base-flows were much closer to measured values. The improved calibration is due mainly to improved specification of the boundary conditions made possible by first solving the far-field problem with an analytic element model.This paper demonstrates that analytic element models have potential as powerful screening tools that can facilitate or improve calibration of more complicated finite-difference and finite-element models. We demonstrate how a two-dimensional analytic element model was used to identify errors in a complex three-dimensional finite-difference model caused by incorrect specification of boundary conditions. An improved finite-difference model was developed using boundary conditions developed from a far-field analytic element model. Calibration of a revised finite-difference model was achieved using fewer zones of hydraulic conductivity and lake bed conductance than the original finite-difference model. Calibration statistics were also improved in that simulated base-flows were much closer to measured values. The improved calibration is due mainly to improved specification of the boundary conditions made possible by first solving the far-field problem with an analytic element model.
Kinetic Titration Series with Biolayer Interferometry
Frenzel, Daniel; Willbold, Dieter
2014-01-01
Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1–42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations. PMID:25229647
Kinetic titration series with biolayer interferometry.
Frenzel, Daniel; Willbold, Dieter
2014-01-01
Biolayer interferometry is a method to analyze protein interactions in real-time. In this study, we illustrate the usefulness to quantitatively analyze high affinity protein ligand interactions employing a kinetic titration series for characterizing the interactions between two pairs of interaction patterns, in particular immunoglobulin G and protein G B1 as well as scFv IC16 and amyloid beta (1-42). Kinetic titration series are commonly used in surface plasmon resonance and involve sequential injections of analyte over a desired concentration range on a single ligand coated sensor chip without waiting for complete dissociation between the injections. We show that applying this method to biolayer interferometry is straightforward and i) circumvents problems in data evaluation caused by unavoidable sensor differences, ii) saves resources and iii) increases throughput if screening a multitude of different analyte/ligand combinations.
Ma, Qiang; Bai, Hua; Li, Wentao; Wang, Chao; Li, Xinshi; Cooks, R Graham; Ouyang, Zheng
2016-03-17
Significantly simplified work flows were developed for rapid analysis of various types of cosmetic and foodstuff samples by employing a miniature mass spectrometry system and ambient ionization methods. A desktop Mini 12 ion trap mass spectrometer was coupled with paper spray ionization, extraction spray ionization and slug-flow microextraction for direct analysis of Sudan Reds, parabens, antibiotics, steroids, bisphenol and plasticizer from raw samples with complex matrices. Limits of detection as low as 5 μg/kg were obtained for target analytes. On-line derivatization was also implemented for analysis of steroid in cosmetics. The developed methods provide potential analytical possibility for outside-the-lab screening of cosmetics and foodstuff products for the presence of illegal substances. Copyright © 2016 Elsevier B.V. All rights reserved.
Wu, Zheng; Zeng, Li-bo; Wu, Qiong-shui
2016-02-01
The conventional cervical cancer screening methods mainly include TBS (the bethesda system) classification method and cellular DNA quantitative analysis, however, by using multiple staining method in one cell slide, which is staining the cytoplasm with Papanicolaou reagent and the nucleus with Feulgen reagent, the study of achieving both two methods in the cervical cancer screening at the same time is still blank. Because the difficulty of this multiple staining method is that the absorbance of the non-DNA material may interfere with the absorbance of DNA, so that this paper has set up a multi-spectral imaging system, and established an absorbance unmixing model by using multiple linear regression method based on absorbance's linear superposition character, and successfully stripped out the absorbance of DNA to run the DNA quantitative analysis, and achieved the perfect combination of those two kinds of conventional screening method. Through a series of experiment we have proved that between the absorbance of DNA which is calculated by the absorbance unmixxing model and the absorbance of DNA which is measured there is no significant difference in statistics when the test level is 1%, also the result of actual application has shown that there is no intersection between the confidence interval of the DNA index of the tetraploid cells which are screened by using this paper's analysis method when the confidence level is 99% and the DNA index's judging interval of cancer cells, so that the accuracy and feasibility of the quantitative DNA analysis with multiple staining method expounded by this paper have been verified, therefore this analytical method has a broad application prospect and considerable market potential in early diagnosis of cervical cancer and other cancers.
Lian, Ru; Wu, Zhongping; Lv, Xiaobao; Rao, Yulan; Li, Haiyang; Li, Jinghua; Wang, Rong; Ni, Chunfang; Zhang, Yurong
2017-10-01
Increasing in cases involving drugs of abuse leads to heavy burden for law enforcement agencies, exacerbating demand for rapid screening technique. In this study, atmospheric pressure ionization technologies including direct analysis in real time (DART) ion source coupled to a time-of-flight mass spectrometer (DART-TOF-MS)as well asdopant-assisted positive photoionization ion mobility spectrometry (DAPP-IMS) without radioactivity were utilized together as the powerful analytical tool for the rapid screening and identification of 53 abused drugs.The limits of detection (LOD) were 0.05-2μg/mL when using DART-TOF-MS and 0.02-2μg when using DAPP-IMS which could satisfy the actual requirement in forensic science laboratory. The advantages of this method included fast response, high-throughput potential, high specificity, and minimal sample preparation. A screening library of reduced mobility (K 0 ), accurate mass of informative precursor ion ([M+H] + ) and fragment ions was established respectively by employing a bench-top DAPP-IMS and TOF-MS in-source collision induced dissociation (CID) mode. Then the standardized screening procedure was developed with criteria for the confirmation of positive result. A total of 50 seized drug samples provided by local forensic laboratory we reanalyzed to testify the utility of the method. This study suggests that a method combing DART-TOF-MS and DAPP-IMS is promising for the rapid screening and identification of abused drugs with minimal sample preparation and absence of chromatography. Copyright © 2017 Elsevier B.V. All rights reserved.
Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina
2011-10-06
Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.
Risk analysis by FMEA as an element of analytical validation.
van Leeuwen, J F; Nauta, M J; de Kaste, D; Odekerken-Rombouts, Y M C F; Oldenhof, M T; Vredenbregt, M J; Barends, D M
2009-12-05
We subjected a Near-Infrared (NIR) analytical procedure used for screening drugs on authenticity to a Failure Mode and Effects Analysis (FMEA), including technical risks as well as risks related to human failure. An FMEA team broke down the NIR analytical method into process steps and identified possible failure modes for each step. Each failure mode was ranked on estimated frequency of occurrence (O), probability that the failure would remain undetected later in the process (D) and severity (S), each on a scale of 1-10. Human errors turned out to be the most common cause of failure modes. Failure risks were calculated by Risk Priority Numbers (RPNs)=O x D x S. Failure modes with the highest RPN scores were subjected to corrective actions and the FMEA was repeated, showing reductions in RPN scores and resulting in improvement indices up to 5.0. We recommend risk analysis as an addition to the usual analytical validation, as the FMEA enabled us to detect previously unidentified risks.
Success and failure of the plasma analogy for Laughlin states on a torus
NASA Astrophysics Data System (ADS)
Fremling, Mikael
2017-01-01
We investigate the nature of the plasma analogy for the Laughlin wave function on a torus describing the quantum Hall plateau at ν =\\frac{1}{q} . We first establish, as expected, that the plasma is screening if there are no short nontrivial paths around the torus. We also find that when one of the handles has a short circumference—i.e. the thin-torus limit—the plasma no longer screens. To quantify this we compute the normalization of the Laughlin state, both numerically and analytically. In the thin torus limit, the analytical form of the normalization simplify and we can reconstruct the normalization and analytically extend it back into the 2D regime. We find that there are geometry dependent corrections to the normalization, and this in turn implies that the plasma in the plasma analogy is not screening when in the thin torus limit. Despite the breaking of the plasma analogy in this limit, the analytical approximation is still a good description of the normalization for all tori, and also allows us to compute hall viscosity at intermediate thickness.
Gentili, Alessandra; Caretti, Fulvia; Ventura, Salvatore; Pérez-Fernández, Virginia; Venditti, Alessandro; Curini, Roberta
2015-08-26
This paper presents an analytical strategy for a large-scale screening of carotenoids in tomato fruits by exploiting the potentialities of the triple quadrupole-linear ion trap hybrid mass spectrometer (QqQLIT). The method involves separation on C30 reversed-phase column and identification by means of diode array detection (DAD) and atmospheric pressure chemical ionization-mass spectrometry (APCI-MS). The authentic standards of six model compounds were used to optimize the separative conditions and to predict the chromatographic behavior of untargeted carotenoids. An information dependent acquisition (IDA) was performed with (i) enhanced-mass scan (EMS) as the survey scan, (ii) enhanced-resolution (ER) scan to obtain the exact mass of the precursor ions (16-35 ppm), and (iii) enhanced product ion (EPI) scan as dependent scan to obtain structural information. LC-DAD-multiple reaction monitoring (MRM) chromatograms were also acquired for the identification of targeted carotenoids occurring at low concentrations; for the first time, the relative abundance between the MRM transitions (ion ratio) was used as an extra tool for the MS distinction of structural isomers and the related families of geometrical isomers. The whole analytical strategy was high-throughput, because a great number of experimental data could be acquired with few analytical steps, and cost-effective, because only few standards were used; when applied to characterize some tomato varieties ('Tangerine', 'Pachino', 'Datterino', and 'Camone') and passata of 'San Marzano' tomatoes, our method succeeded in identifying up to 44 carotenoids in the 'Tangerine'" variety.
Peters, Frank T; Schaefer, Simone; Staack, Roland F; Kraemer, Thomas; Maurer, Hans H
2003-06-01
The classical stimulants amphetamine, methamphetamine, ethylamphetamine and the amphetamine-derived designer drugs MDA, MDMA ('ecstasy'), MDEA, BDB and MBDB have been widely abused for a relatively long time. In recent years, a number of newer designer drugs have entered the illicit drug market. 4-Methylthioamphetamine (MTA), p-methoxyamphetamine (PMA) and p-methoxymethamphetamine (PMMA) are also derived from amphetamine. Other designer drugs are derived from piperazine, such as benzylpiperazine (BZP), methylenedioxybenzylpiperazine (MDBP), trifluoromethylphenylpiperazine (TFMPP), m-chlorophenylpiperazine (mCPP) and p-methoxyphenylpiperazine (MeOPP). A number of severe or even fatal intoxications involving these newer substances, especially PMA, have been reported. This paper describes a method for screening for and simultaneous quantification of the above-mentioned compounds and the metabolites p-hydroxyamphetamine and p-hydroxymethamphetamine (pholedrine) in human blood plasma. The analytes were analyzed by gas chromatography/mass spectrometry in the selected-ion monitoring mode after mixed-mode solid-phase extraction (HCX) and derivatization with heptafluorobutyric anhydride. The method was fully validated according to international guidelines. It was linear from 5 to 1000 micro g l(-1) for all analytes. Data for accuracy and precision were within required limits with the exception of those for MDBP. The limit of quantification was 5 micro g l(-1) for all analytes. The applicability of the assay was proven by analysis of authentic plasma samples and of a certified reference sample. This procedure should also be suitable for confirmation of immunoassay results positive for amphetamines and/or designer drugs of the ecstasy type. Copyright 2003 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Lohmann, R. A.; Riecke, G. T.
1977-01-01
An analytical screening study was conducted to identify duct burner concepts capable of providing low emissions and high performance in advanced supersonic engines. Duct burner configurations ranging from current augmenter technology to advanced concepts such as premix-prevaporized burners were defined. Aerothermal and mechanical design studies provided the basis for screening these configurations using the criteria of emissions, performance, engine compatibility, cost, weight and relative risk. Technology levels derived from recently defined experimental low emissions main burners are required to achieve both low emissions and high performance goals. A configuration based on the Vorbix (Vortex burning and mixing) combustor concept was analytically determined to meet the performance goals and is consistent with the fan duct envelope of a variable cycle engine. The duct burner configuration has a moderate risk level compatible with the schedule of anticipated experimental programs.
Goon, Arnab; Khan, Zareen; Oulkar, Dasharath; Shinde, Raviraj; Gaikwad, Suresh; Banerjee, Kaushik
2018-01-12
A novel screening and quantitation method is reported for non-target multiresidue analysis of pesticides using ultra-HPLC-quadrupole-Orbitrap mass spectrometry in spice matrices, including black pepper, cardamom, chili, coriander, cumin, and turmeric. The method involved sequential full-scan (resolution = 70,000), and variable data independent acquisition (vDIA) with nine consecutive fragmentation events (resolution = 17,500). Samples were extracted by the QuEChERS method. The introduction of an SPE-based clean-up step through hydrophilic-lipophilic-balance (HLB) cartridges proved advantageous in minimizing the false negatives. For coriander, cumin, chili, and cardamom, the screening detection limit was largely at 2 ng/g, while it was 5 ng/g for black pepper, and turmeric. When the method was quantitatively validated for 199 pesticides, the limit of quantification (LOQ) was mostly at 10 ng/g (excluding black pepper, and turmeric with LOQ = 20 ng/g) with recoveries within 70-120%, and precision-RSDs <20%. Furthermore, the method allowed the identification of suspected non-target analytes through retrospective search of the accurate mass of the compound-specific precursor and product ions. Compared to LC-MS/MS, the quantitative performance of this Orbitrap-MS method had agreements in residue values between 78-100%. Copyright © 2017 Elsevier B.V. All rights reserved.
Controlling false-negative errors in microarray differential expression analysis: a PRIM approach.
Cole, Steve W; Galic, Zoran; Zack, Jerome A
2003-09-22
Theoretical considerations suggest that current microarray screening algorithms may fail to detect many true differences in gene expression (Type II analytic errors). We assessed 'false negative' error rates in differential expression analyses by conventional linear statistical models (e.g. t-test), microarray-adapted variants (e.g. SAM, Cyber-T), and a novel strategy based on hold-out cross-validation. The latter approach employs the machine-learning algorithm Patient Rule Induction Method (PRIM) to infer minimum thresholds for reliable change in gene expression from Boolean conjunctions of fold-induction and raw fluorescence measurements. Monte Carlo analyses based on four empirical data sets show that conventional statistical models and their microarray-adapted variants overlook more than 50% of genes showing significant up-regulation. Conjoint PRIM prediction rules recover approximately twice as many differentially expressed transcripts while maintaining strong control over false-positive (Type I) errors. As a result, experimental replication rates increase and total analytic error rates decline. RT-PCR studies confirm that gene inductions detected by PRIM but overlooked by other methods represent true changes in mRNA levels. PRIM-based conjoint inference rules thus represent an improved strategy for high-sensitivity screening of DNA microarrays. Freestanding JAVA application at http://microarray.crump.ucla.edu/focus
Analytical representation of dynamical quantities in G W from a matrix resolvent
NASA Astrophysics Data System (ADS)
Gesenhues, J.; Nabok, D.; Rohlfing, M.; Draxl, C.
2017-12-01
The power of the G W formalism is, to a large extent, based on the explicit treatment of dynamical correlations in the self-energy. This dynamics is taken into account by calculating the energy dependence of the screened Coulomb interaction W , followed by a convolution with the Green's function G . In order to obtain the energy dependence of W the prevalent methods are plasmon-pole models and numerical integration techniques. In this paper, we discuss an alternative approach, in which the energy-dependent screening is calculated by determining the resolvent, which is set up from a matrix representation of the dielectric function. On the one hand, this refrains from a numerical energy convolution and allows one to actually write down the energy dependence of W explicitly (like in the plasmon-pole models). On the other hand, the method is at least as accurate as the numerical approaches due to its multipole nature. We discuss the theoretical setup in some detail, give insight into the computational aspects, and present results for Si, C, GaAs, and LiF. Finally, we argue that the analytic representability is not only useful for educational purposes but may also be of avail for the development of theory that goes beyond G W .
CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF ...
Synthetic musk compounds have been found in surface water, fish tissues, and human breast milk. Current techniques for separating these compounds from fish tissues require tedious sample clean-upprocedures A simple method for the deterrnination of these compounds in fish tissues has been developed. Closed-loop stripping of saponified fish tissues in a I -L Wheaton purge-and-trap vessel is used to strip compounds with high vapor pressures such as synthetic musks from the matrix onto a solid sorbent (Abselut Nexus). This technique is useful for screening biological tissues that contain lipids for musk compounds. Analytes are desorbed from the sorbent trap sequentially with polar and nonpolar solvents, concentrated, and directly analyzed by high resolution gas chromatography coupled to a mass spectrometer operating in the selected ion monitoring mode. In this paper, we analyzed two homogenized samples of whole fish tissues with spiked synthetic musk compounds using closed-loop stripping analysis (CLSA) and pressurized liquid extraction (PLE). The analytes were not recovered quantitatively but the extraction yield was sufficiently reproducible for at least semi-quantitative purposes (screening). The method was less expensive to implement and required significantly less sample preparation than the PLE technique. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water,
Badoud, F; Grata, E; Perrenoud, L; Avois, L; Saugy, M; Rudaz, S; Veuthey, J-L
2009-05-15
The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.
Mass spectrometry as a quantitative tool in plant metabolomics
Jorge, Tiago F.; Mata, Ana T.
2016-01-01
Metabolomics is a research field used to acquire comprehensive information on the composition of a metabolite pool to provide a functional screen of the cellular state. Studies of the plant metabolome include the analysis of a wide range of chemical species with very diverse physico-chemical properties, and therefore powerful analytical tools are required for the separation, characterization and quantification of this vast compound diversity present in plant matrices. In this review, challenges in the use of mass spectrometry (MS) as a quantitative tool in plant metabolomics experiments are discussed, and important criteria for the development and validation of MS-based analytical methods provided. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644967
Micro-ring sensor used in the diagnosis of gastric cancer
NASA Astrophysics Data System (ADS)
Shi, Sichao; Cheng, Qing; Lin, Rong; Su, Da; Huang, Ying
2016-01-01
To find a detecting method that can be applied to the clinical screening and diagnosis, the cascaded micro-ring sensor with Vernier effect was used to distinguish gastric cancerous and normal cells. The simulation by FDTD of the cascaded microring sensor with different refractive indexes of the analyte (normal cells and gastric cancer cells) will be presented. In the simulation, with the refractive index's change Δn=0.02 for the two different analyte, the shift of sensor's resonant wavelength is 6.71nm. And the cascaded micro-ring sensor's sensitivity S is 335.5nm/RIU, and it is much larger compared to 19nm/RIU for a single ring sensor.
Landy, Rebecca; Cheung, Li C; Schiffman, Mark; Gage, Julia C; Hyun, Noorie; Wentzensen, Nicolas; Kinney, Walter K; Castle, Philip E; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas; Sasieni, Peter D; Katki, Hormuzd A
2018-06-01
Electronic health-records (EHR) are increasingly used by epidemiologists studying disease following surveillance testing to provide evidence for screening intervals and referral guidelines. Although cost-effective, undiagnosed prevalent disease and interval censoring (in which asymptomatic disease is only observed at the time of testing) raise substantial analytic issues when estimating risk that cannot be addressed using Kaplan-Meier methods. Based on our experience analysing EHR from cervical cancer screening, we previously proposed the logistic-Weibull model to address these issues. Here we demonstrate how the choice of statistical method can impact risk estimates. We use observed data on 41,067 women in the cervical cancer screening program at Kaiser Permanente Northern California, 2003-2013, as well as simulations to evaluate the ability of different methods (Kaplan-Meier, Turnbull, Weibull and logistic-Weibull) to accurately estimate risk within a screening program. Cumulative risk estimates from the statistical methods varied considerably, with the largest differences occurring for prevalent disease risk when baseline disease ascertainment was random but incomplete. Kaplan-Meier underestimated risk at earlier times and overestimated risk at later times in the presence of interval censoring or undiagnosed prevalent disease. Turnbull performed well, though was inefficient and not smooth. The logistic-Weibull model performed well, except when event times didn't follow a Weibull distribution. We have demonstrated that methods for right-censored data, such as Kaplan-Meier, result in biased estimates of disease risks when applied to interval-censored data, such as screening programs using EHR data. The logistic-Weibull model is attractive, but the model fit must be checked against Turnbull non-parametric risk estimates. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Variable Screening for Cluster Analysis.
ERIC Educational Resources Information Center
Donoghue, John R.
Inclusion of irrelevant variables in a cluster analysis adversely affects subgroup recovery. This paper examines using moment-based statistics to screen variables; only variables that pass the screening are then used in clustering. Normal mixtures are analytically shown often to possess negative kurtosis. Two related measures, "m" and…
Sun, Baoguo; Miller, Gregory; Lee, Wan Yee; Ho, Kelvin; Crowe, Michael A; Partridge, Leslie
2013-01-04
Analytical methods were developed for a directed enzyme evolution research programme, which pursued high performance enzymes to produce high quality L-ribose using large scale biocatalytic reaction. A high throughput HPLC method with evaporative light-scattering detection was developed to test ribose and ribitol in the enzymatic reaction, a β-cyclobond 2000 analytical column separated ribose and ribitol in 2.3 min, a C(18) guard column was used as an on-line filter to clean up the enzyme sample matrix and a short gradient was applied to wash the column, the enzymatic reaction solution can be directly injected after quenching. Total run time of each sample was approx. 4 min which provided capability of screening 4×96-well plates/day/instrument. Meanwhile, a capillary electrophoresis method was developed for the separation of ribose enantiomers, while 7-aminonaphthalene-1,3-disulfonic acid was used as derivatisation reagent and 25 mM tetraborate with 5 mM β-cyclodextrin was used as electrolyte. 0.35%of D-ribose in L-ribose can be detected which can be translated into 99.3% ee of L-ribose. Derivatisation reagent and sample matrix did not interfere with the measurement. Copyright © 2012 Elsevier B.V. All rights reserved.
Rajabi, Maryam; Sabzalian, Sedigheh; Barfi, Behruz; Arghavani-Beydokhti, Somayeh; Asghari, Alireza
2015-12-18
A novel, simple, fast, and miniaturized method, termed in-line micro-matrix solid-phase dispersion (in-line MMSPD), coupled with high performance liquid chromatography (HPLC) was developed for the simultaneous extraction and determination of Sudan dyes (i.e. Sudan I-IV, Sudan orange G, Sudan black B, and Sudan red G) with the aid of an experimental design strategy. In this method, a matrix solid-phase dispersion (MSPD) column including a suitable mixture of polar sorbents was inserted in the mobile phase pathway, and while the interfering compounds were retained, the analytes were eluted and entered into the analytical column. In this way, the extraction, elution, and separation of the analytes were performed sequentially. Under the optimal experimental conditions (including the amount of sample, 0.0426g; amount of dispersant phase, 0.0216g of florisil, 0.0227g of silica, 0.0141g of alumina; and blending time, 112s), the limits of detection (LODs), limits of quantification, linear dynamic ranges, and recoveries were obtained to be 0.3-15.3μgkg(-1), 1-50μgkg(-1), 50-28,000μgkg(-1), and 94.5-99.1%, respectively. The results obtained showed that determination of the selected Sudan dyes in food samples using an enough sensitive and a simple analytically validated method like in-line MMSPD may offer a suitable screening method, which could be useful for food analysis and adulteration. Copyright © 2015 Elsevier B.V. All rights reserved.
Hsieh, Han-Yun; Shyu, Ching-Lin; Liao, Chen-Wei; Lee, Ren-Jye; Lee, Maw-Rong; Vickroy, Thomas W; Chou, Chi-Chung
2012-04-01
Zeranol (Z) is a semi-synthetic mycotoxin that is used in some countries as a growth-promoting agent in livestock. In view of the known oestrogenic actions by Z and certain Z analogues, significant concerns exist with regard to the presence of Z residues in human foods and the potential for untoward effects, including carcinogenicity within the reproductive system. In order to confirm that foods are free from harmful Z residues, regulators need a quick and reliable analytical method that can be used for routine confirmation of Z-positive samples identified by enzyme-linked immunosorbent assay (ELISA) screening. In this study the authors have developed and validated a simple and rapid high-performance liquid chromatography method incorporating ultraviolet (UV) absorbance (wavelength 274 nm) and electrochemical (EC) dual-mode detection for simultaneous determination of Z-related mycotoxins produced from mouldy grain matrices, including rice, soybean and corn flakes. Recoveries for all analytes were around 80% and the limits of detection ranged from 10 to 25 ng mL(-1) for UV and from 50 to 90 ng mL(-1) for EC detection with good accuracy and reproducibility. Differential profiles and occurrence rates of Z, β-zearalenol, β-zearalanol and α-zearalenol in naturally moulded grain matrices were observed, indicating different metabolite patterns and possibly grain-specific effects of mycotoxin exposure for humans and animals. The strength of this dual detection method lies in its selectivity characterised by a carbon screen-printed electrode such that aflatoxin interference is precluded. The combined dual detection technique affords quick and reliable semi-confirmative and quantitative information on multiple types of Z analogues in mouldy grains without the necessity of using expensive mass spectrometry. The method is considered a superior supplement to ELISA, which only screens total Z immunoreactivity. Copyright © 2011 Society of Chemical Industry.
Qi, Jin; Sun, Li-Qiong; Qian, Steven Y; Yu, Bo-Yang
2017-09-01
Natural products, such as rosmarinic acid and apigenin, can act as xanthine oxidase inhibitors (XOIs) as well as superoxide anion scavengers, and have potential for treatment of diseases associated with high uric acid levels and oxidative stress. However, efficient simultaneous screening of these two bioactivities in natural products has been challenging. We have developed a novel method by assembling a multi-hyphenated high performance liquid chromatography (HPLC) system that combines a photo-diode array, chemiluminescence detector and a HPLC system with a variable wavelength detector, to simultaneously detect components that act as both XOIs and superoxide anion scavengers in natural products. Superoxide anion scavenging activity in the analyte was measured by on-line chemiluminescence chromatography based on pyrogallol-luminol oxidation, while xanthine oxidase inhibitory activity was determined by semi-on-line HPLC analysis. After optimizing multiple elements, including chromatographic conditions (e.g., organic solvent concentration and mobile phase pH), concentrations of xanthine/xanthine oxidase and reaction temperature, our validated analytical method was capable of mixed sample analysis. The final results from our method are presented in an easily understood visual format including comprehensive bioactivity data of natural products. Copyright © 2017. Published by Elsevier B.V.
Liu, Hongcheng; Lin, Xin; Lin, Tao; Zhang, Yulong; Luo, Yinglan; Li, Qiwan
2016-09-01
A simple, accurate, and highly sensitive analytical method was developed in this study for the determination of nine β-agonists in milk. In this method, a new magnetic adsorbent of molecularly imprinted polymers/magnetic nanoparticles prepared by simple physical blending was adopted, which enabled magnetic solid-phase extraction. Thus, the resultant material can be separated from the solvent rapidly and conveniently by a magnet. Two kinds of molecularly imprinted polymer/magnetic nanoparticles materials were fabricated, and the characteristics of materials such as the ratio, pH, amount, desorption, and regeneration were investigated. The analytes were quantified by ultra high performance liquid chromatography coupled to an electrospray ionization tandem mass spectrometer operating in multiple reaction monitoring modes. The detection limit of the method was 0.003-0.3 μg/L, and the detection capability was 0.01-0.3 μg/L. The recoveries of these compounds were 65.7-114% at three spiked levels. Reproducibility represented by relative standard deviation was 11.2% or less. The method was successfully applied to the screening of real samples obtained from local markets and confirmation of the suspected target analytes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Direct screening and confirmation of priority volatile organic pollutants in drinking water.
Caro, J; Serrano, A; Gallego, M
2007-01-05
A screening tool was proposed for the rapid detection of eight priority volatile organic pollutants according to European standards in drinking water. The method is based on the direct coupling of a headspace sampler with a mass spectrometer, using a chromatographic column heated to 175 degrees C as an interface. The water sample was subjected to the headspace extraction process and the volatile fraction was introduced directly into the mass spectrometer, without prior chromatographic separation, achieving low detection limits (0.6-1.2 ng/ml) for all compounds. The mass spectrum resulting from the simultaneous ionization and fragmentation of the mixture of molecules constitutes the volatile profile of each sample. An appropriate chemometric treatment of these signals permitted them to be classified, on the basis of their volatile composition, as contaminated or uncontaminated with respect to the legally established concentration levels for these compounds in drinking water, and providing no false negatives. A conventional confirmation method was carried out to analyze positive water samples by using the same instrumental setup as in the screening method, but using an appropriate temperature program in the chromatographic column to separate, identify and quantify each analyte.
A Review of Current Methods for Analysis of Mycotoxins in Herbal Medicines
Zhang, Lei; Dou, Xiao-Wen; Zhang, Cheng; Logrieco, Antonio F.; Yang, Mei-Hua
2018-01-01
The presence of mycotoxins in herbal medicines is an established problem throughout the entire world. The sensitive and accurate analysis of mycotoxin in complicated matrices (e.g., herbs) typically involves challenging sample pretreatment procedures and an efficient detection instrument. However, although numerous reviews have been published regarding the occurrence of mycotoxins in herbal medicines, few of them provided a detailed summary of related analytical methods for mycotoxin determination. This review focuses on analytical techniques including sampling, extraction, cleanup, and detection for mycotoxin determination in herbal medicines established within the past ten years. Dedicated sections of this article address the significant developments in sample preparation, and highlight the importance of this procedure in the analytical technology. This review also summarizes conventional chromatographic techniques for mycotoxin qualification or quantitation, as well as recent studies regarding the development and application of screening assays such as enzyme-linked immunosorbent assays, lateral flow immunoassays, aptamer-based lateral flow assays, and cytometric bead arrays. The present work provides a good insight regarding the advanced research that has been done and closes with an indication of future demand for the emerging technologies. PMID:29393905
NASA Astrophysics Data System (ADS)
Khorashadi Zadeh, Farkhondeh; Nossent, Jiri; van Griensven, Ann; Bauwens, Willy
2017-04-01
Parameter estimation is a major concern in hydrological modeling, which may limit the use of complex simulators with a large number of parameters. To support the selection of parameters to include in or exclude from the calibration process, Global Sensitivity Analysis (GSA) is widely applied in modeling practices. Based on the results of GSA, the influential and the non-influential parameters are identified (i.e. parameters screening). Nevertheless, the choice of the screening threshold below which parameters are considered non-influential is a critical issue, which has recently received more attention in GSA literature. In theory, the sensitivity index of a non-influential parameter has a value of zero. However, since numerical approximations, rather than analytical solutions, are utilized in GSA methods to calculate the sensitivity indices, small but non-zero indices may be obtained for the indices of non-influential parameters. In order to assess the threshold that identifies non-influential parameters in GSA methods, we propose to calculate the sensitivity index of a "dummy parameter". This dummy parameter has no influence on the model output, but will have a non-zero sensitivity index, representing the error due to the numerical approximation. Hence, the parameters whose indices are above the sensitivity index of the dummy parameter can be classified as influential, whereas the parameters whose indices are below this index are within the range of the numerical error and should be considered as non-influential. To demonstrated the effectiveness of the proposed "dummy parameter approach", 26 parameters of a Soil and Water Assessment Tool (SWAT) model are selected to be analyzed and screened, using the variance-based Sobol' and moment-independent PAWN methods. The sensitivity index of the dummy parameter is calculated from sampled data, without changing the model equations. Moreover, the calculation does not even require additional model evaluations for the Sobol' method. A formal statistical test validates these parameter screening results. Based on the dummy parameter screening, 11 model parameters are identified as influential. Therefore, it can be denoted that the "dummy parameter approach" can facilitate the parameter screening process and provide guidance for GSA users to define a screening-threshold, with only limited additional resources. Key words: Parameter screening, Global sensitivity analysis, Dummy parameter, Variance-based method, Moment-independent method
Doshi, Gaurav Mahesh; Zine, Sandeep Prabhakar; Chaskar, Pratip Kashinath; Une, Hemant Devidas
2014-01-01
Background: Polyalthia longifolia Thwaites is an important traditional plant in India. Rutin, an active constituent has been reported to possess good amount of pharmacological as well as therapeutic potential. Objective: The aim of the present study was to find out by analytical techniques how much percentage of rutin is present in the plant leaves’ ethanolic extract by analytical techniques. Materials and Methods: Shade dried leaves of Polyalthia longifolia were subjected to cold ethanolic extraction followed by monitoring the isolated rutin high-pressure liquid chromatography (HPLC) and high performance thin layer chromatography (HPTLC) after carrying out preliminary phytochemical screening. Results: Extraction yield was found to be 13.94% w/w. Phytochemical screening of the extract showed the presence of flavonoids, steroids, diterpenoids, alkaloids, saponins, tannins and phenolic compounds and mucilage. From the Rf value, the ethanolic extract was found to be having constituent identical to rutin. By HPTLC and HPLC the amount of rutin was found to be 11.60% w/w and 4.03% w/v, respectively. Conclusion: The active constituent isolated was found to be equal to rutin. PMID:25002804
Prioritizing pesticide compounds for analytical methods development
Norman, Julia E.; Kuivila, Kathryn; Nowell, Lisa H.
2012-01-01
The U.S. Geological Survey (USGS) has a periodic need to re-evaluate pesticide compounds in terms of priorities for inclusion in monitoring and studies and, thus, must also assess the current analytical capabilities for pesticide detection. To meet this need, a strategy has been developed to prioritize pesticides and degradates for analytical methods development. Screening procedures were developed to separately prioritize pesticide compounds in water and sediment. The procedures evaluate pesticide compounds in existing USGS analytical methods for water and sediment and compounds for which recent agricultural-use information was available. Measured occurrence (detection frequency and concentrations) in water and sediment, predicted concentrations in water and predicted likelihood of occurrence in sediment, potential toxicity to aquatic life or humans, and priorities of other agencies or organizations, regulatory or otherwise, were considered. Several existing strategies for prioritizing chemicals for various purposes were reviewed, including those that identify and prioritize persistent, bioaccumulative, and toxic compounds, and those that determine candidates for future regulation of drinking-water contaminants. The systematic procedures developed and used in this study rely on concepts common to many previously established strategies. The evaluation of pesticide compounds resulted in the classification of compounds into three groups: Tier 1 for high priority compounds, Tier 2 for moderate priority compounds, and Tier 3 for low priority compounds. For water, a total of 247 pesticide compounds were classified as Tier 1 and, thus, are high priority for inclusion in analytical methods for monitoring and studies. Of these, about three-quarters are included in some USGS analytical method; however, many of these compounds are included on research methods that are expensive and for which there are few data on environmental samples. The remaining quarter of Tier 1 compounds are high priority as new analytes. The objective for analytical methods development is to design an integrated analytical strategy that includes as many of the Tier 1 pesticide compounds as possible in a relatively few, cost-effective methods. More than 60 percent of the Tier 1 compounds are high priority because they are anticipated to be present at concentrations approaching levels that could be of concern to human health or aquatic life in surface water or groundwater. An additional 17 percent of Tier 1 compounds were frequently detected in monitoring studies, but either were not measured at levels potentially relevant to humans or aquatic organisms, or do not have benchmarks available with which to compare concentrations. The remaining 21 percent are pesticide degradates that were included because their parent pesticides were in Tier 1. Tier 1 pesticide compounds for water span all major pesticide use groups and a diverse range of chemical classes, with herbicides and their degradates composing half of compounds. Many of the high priority pesticide compounds also are in several national regulatory programs for water, including those that are regulated in drinking water by the U.S. Environmental Protection Agency under the Safe Drinking Water Act and those that are on the latest Contaminant Candidate List. For sediment, a total of 175 pesticide compounds were classified as Tier 1 and, thus, are high priority for inclusion in analytical methods available for monitoring and studies. More than 60 percent of these compounds are included in some USGS analytical method; however, some are spread across several research methods that are expensive to perform, and monitoring data are not extensive for many compounds. The remaining Tier 1 compounds for sediment are high priority as new analytes. The objective for analytical methods development for sediment is to enhance an existing analytical method that currently includes nearly half of the pesticide compounds in Tier 1 by adding as many additional Tier 1 compounds as are analytically compatible. About 35 percent of the Tier 1 compounds for sediment are high priority on the basis of measured occurrence. A total of 74 compounds, or 42 percent, are high priority on the basis of predicted likelihood of occurrence according to physical-chemical properties, and either have potential toxicity to aquatic life, high pesticide useage, or both. The remaining 22 percent of Tier 1 pesticide compounds were either degradates of Tier 1 parent compounds or included for other reasons. As with water, the Tier 1 pesticide compounds for sediment are distributed across the major pesticide-use groups; insecticides and their degradates are the largest fraction, making up 45 percent of Tier 1. In contrast to water, organochlorines, at 17 percent, are the largest chemical class for Tier 1 in sediment, which is to be expected because there is continued widespread detection in sediments of persistent organochlorine pesticides and their degradates at concentrations high enough for potential effects on aquatic life. Compared to water, there are fewer available benchmarks with which to compare contaminant concentrations in sediment, but a total of 19 Tier 1 compounds have at least one sediment benchmark or screening value for aquatic organisms. Of the 175 compounds in Tier 1, 77 percent have high aquatic-life toxicity, as defined for this process. This evaluation of pesticides and degradates resulted in two lists of compounds that are priorities for USGS analytical methods development, one for water and one for sediment. These lists will be used as the basis for redesigning and enhancing USGS analytical capabilities for pesticides in order to capture as many high-priority pesticide compounds as possible using an economically feasible approach.
Tobe, Ruoyan Gai; Mori, Rintaro; Huang, Lihui; Xu, Lingzhong; Han, Demin; Shibuya, Kenji
2013-01-01
Background In 2009, the Chinese Ministry of Health recommended scale-up of routine neonatal hearing screening - previously performed primarily only in select urban hospitals - throughout the entire country. Methods A decision analytical model for a simulated population of all live births in China was developed to compare the costs and health effects of five mutually exclusive interventions: 1) universal screening using Otoacoustic Emission (OAE) and Automated Auditory Brainstem Response (AABR); 2) universal OAE; 3) targeted OAE and AABR; 4) targeted OAE; and 5) no screening. Disability-Adjusted Life Years (DALYs) were calculated for health effects. Results and Discussion Based on the cost-effectiveness and potential health outcomes, the optimal path for scale-up would be to start with targeted OAE and then expand to universal OAE and universal OAE plus AABR. Accessibility of screening, diagnosis, and intervention services significantly affect decision of the options. Conclusion In conclusion, to achieve cost-effectiveness and best health outcomes of the NHS program, the accessibility of screening, diagnosis, and intervention services should be expanded to reach a larger population. The results are thus expected to be of particular benefit in terms of the ‘rolling out’ of the national plan. PMID:23341887
Orlandini, Serena; Pasquini, Benedetta; Caprini, Claudia; Del Bubba, Massimo; Pinzauti, Sergio; Furlanetto, Sandra
2015-11-01
A fast and selective CE method for the determination of zolmitriptan (ZOL) and its five potential impurities has been developed applying the analytical Quality by Design principles. Voltage, temperature, buffer concentration, and pH were investigated as critical process parameters that can influence the critical quality attributes, represented by critical resolution values between peak pairs, analysis time, and peak efficiency of ZOL-dimer. A symmetric screening matrix was employed for investigating the knowledge space, and a Box-Behnken design was used to evaluate the main, interaction, and quadratic effects of the critical process parameters on the critical quality attributes. Contour plots were drawn highlighting important interactions between buffer concentration and pH, and the gained information was merged into the sweet spot plots. Design space (DS) was established by the combined use of response surface methodology and Monte Carlo simulations, introducing a probability concept and thus allowing the quality of the analytical performances to be assured in a defined domain. The working conditions (with the interval defining the DS) were as follows: BGE, 138 mM (115-150 mM) phosphate buffer pH 2.74 (2.54-2.94); temperature, 25°C (24-25°C); voltage, 30 kV. A control strategy was planned based on method robustness and system suitability criteria. The main advantages of applying the Quality by Design concept consisted of a great increase of knowledge of the analytical system, obtained throughout multivariate techniques, and of the achievement of analytical assurance of quality, derived by probability-based definition of DS. The developed method was finally validated and applied to the analysis of ZOL tablets. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lautié, E; Rozet, E; Hubert, P; Vandelaer, N; Billard, F; Felde, T Zum; Grüneberg, W J; Quetin-Leclercq, J
2013-12-15
The purpose of the research was to develop and validate a rapid quantification method able to screen many samples of yam bean seeds to determine the content of two toxic polyphenols, namely pachyrrhizine and rotenone. The analytical procedure described is based on the use of an internal standard (dihydrorotenone) and is divided in three steps: microwave assisted extraction, purification by solid phase extraction and assay by ultra high performance liquid chromatography (UHPLC). Each step was included in the validation protocol and the accuracy profiles methodology was used to fully validate the method. The method was fully validated between 0.25 mg and 5 mg pachyrrhizin per gram of seeds and between 0.58 mg/g and 4 mg/g for rotenone. More than one hundred samples from different accessions, locations of growth and harvest dates were screened. Pachyrrhizine concentrations ranged from 3.29 mg/g to lower than 0.25 mg/g while rotenone concentrations ranged from 3.53 mg/g to lower than 0.58 mg/g. This screening along with principal component analysis (PCA) and discriminant analysis (DA) analyses allowed the selection of the more interesting genotypes in terms of low concentrations of these two toxic polyphenols. © 2013 Elsevier B.V. All rights reserved.
Farcaş, E; Bouckaert, C; Servais, A-C; Hanson, J; Pochet, L; Fillet, M
2017-09-01
With the emergence of more challenging targets, a relatively new approach, fragment-based drug discovery (FBDD), proved its efficacy and gained increasing importance in the pharmaceutical industry. FBDD identifies low molecular-weight (MW) ligands (fragments) that bind to biologically important macromolecules, then a structure-guided fragment growing or merging approach is performed, contributing to the quality of the lead. However, to select the appropriate fragment to be evolved, sensitive analytical screening methods must be used to measure the affinity in the μM or even mM range. In this particular context, we developed a robust and selective partial filling affinity CE (ACE) method for the direct binding screening of a small fragment library in order to identify new thrombin inhibitors. To demonstrate the accuracy of our assay, the complex dissociation constants of three known thrombin inhibitors, namely benzamidine, p-aminobenzamidine and nafamostat were determined and found to be in good concordance with the previously reported values. Finally, the screening of a small library was performed and demonstrated the high discriminatory power of our method towards weak binders compared to classical spectrophotometric activity assay, proving the interest of our method in the context of FBDD. Copyright © 2017 Elsevier B.V. All rights reserved.
Determination of Ochratoxin A in Rye and Rye-Based Products by Fluorescence Polarization Immunoassay
Lippolis, Vincenzo; Porricelli, Anna C. R.; Cortese, Marina; Zanardi, Sandro; Pascale, Michelangelo
2017-01-01
A rapid fluorescence polarization immunoassay (FPIA) was optimized and validated for the determination of ochratoxin A (OTA) in rye and rye crispbread. Samples were extracted with a mixture of acetonitrile/water (60:40, v/v) and purified by SPE-aminopropyl column clean-up before performing the FPIA. Overall mean recoveries were 86 and 95% for spiked rye and rye crispbread with relative standard deviations lower than 6%. Limits of detection (LOD) of the optimized FPIA was 0.6 μg/kg for rye and rye crispbread, respectively. Good correlations (r > 0.977) were observed between OTA contents in contaminated samples obtained by FPIA and high-performance liquid chromatography (HPLC) with immunoaffinity cleanup used as reference method. Furthermore, single laboratory validation and small-scale collaborative trials were carried out for the determination of OTA in rye according to Regulation 519/2014/EU laying down procedures for the validation of screening methods. The precision profile of the method, cut-off level and rate of false suspect results confirm the satisfactory analytical performances of assay as a screening method. These findings show that the optimized FPIA is suitable for high-throughput screening, and permits reliable quantitative determination of OTA in rye and rye crispbread at levels that fall below the EU regulatory limits. PMID:28954398
Vaiano, Fabio; Busardò, Francesco P; Palumbo, Diego; Kyriakou, Chrystalla; Fioravanti, Alessia; Catalani, Valeria; Mari, Francesco; Bertol, Elisabetta
2016-09-10
Identification and quantification of new psychoactive substances (NPS), both in biological and non-biological samples, represent a hard challenge for forensic toxicologists. NPS are increasingly emerging on illegal drug market. Many cases of co-consumption of NPS and other substances have also been reported. Hence, the development of analytical methods aiming at the detection of a broad-spectrum of compounds (NPS and "traditional" drugs) could be helpful. In this paper, a fully validated screening method in blood for the simultaneous detection of 69 substances, including 64 NPS (28 synthetic cannabinoids, 19 synthetic cathinones, 5 phenethylamines, 3 indanes, 2 piperazines, 2 tryptamines, 2 phencyclidine, methoxetamine, ketamine and its metabolite) and 5 amphetamines (amphetamine, methamphetamine, MDMA, MDA, 3,4-methylenedioxy-N-ethylamphetamine - MDEA-) by a dynamic multiple reaction monitoring analysis through liquid chromatography - tandem mass spectrometry (LC-MS/MS) is described. This method is very fast, easy to perform and cheap as it only requires the deproteinization of 200μL of blood sample with acetonitrile. The chromatographic separation is achieved with a C18 column. The analysis is very sensitive, with limits of quantification ranging from 0.1 to 0.5ng/mL. The method is linear from 1 to 100ng/mL and the coefficient of determination (R(2)) was always above 0.9900. Precision and accuracy were acceptable at any quality control level and recovery efficiency range was 72-110%. Matrix effects did not negatively affect the analytical sensitivity. This method was successfully applied to three real cases, allowing identification and quantification of: mephedrone and methamphetamine (post-mortem); ketamine, MDMA and MDA (post-mortem); AB-FUBINACA (ante-mortem). Copyright © 2016 Elsevier B.V. All rights reserved.
Gibs, Jacob; Brown, G. Allan; Turner, Kenneth S.; MacLeod, Cecilia L.; Jelinski, James; Koehnlein, Susan A.
1993-01-01
Because a water sample collected from a well is an integration of water from different depths along the well screen, measured concentrations can be biased if analyte concentrations are not uniform along the length of the well screen. The resulting concentration in the sample, therefore, is a function of variations in well-screen inflow rate and analyte concentration with depth. A multiport sampler with seven short screened intervals was designed and used to investigate small-scale vertical variations in water chemistry and aquifer hydraulic conductivity in ground water contaminated by leaded gasoline at Galloway Township, Atlantic County, New Jersey. The multiport samplers were used to collect independent samples from seven intervals within the screened zone that were flow-rate weighted and integrated to simulate a 5-foot-long, 2.375-inch- outside-diameter conventional wire-wound screen. The integration of the results of analyses of samples collected from two multiport samplers showed that a conventional 5-foot-long well screen would integrate contaminant concentrations over its length and resulted in an apparent contaminant concentration that was a little as 28 percent of the maximum concentration observed in the multiport sampler.
Peters, R J B; Oosterink, J E; Stolker, A A M; Georgakopoulos, C; Nielen, M W F
2010-04-01
A unification of doping-control screening procedures of prohibited small molecule substances--including stimulants, narcotics, steroids, beta2-agonists and diuretics--is highly urgent in order to free resources for new classes such as banned proteins. Conceptually this may be achieved by the use of a combination of one gas chromatography-time-of-flight mass spectrometry method and one liquid chromatography-time-of-flight mass spectrometry method. In this work a quantitative screening method using high-resolution liquid chromatography in combination with accurate-mass time-of-flight mass spectrometry was developed and validated for determination of glucocorticosteroids, beta2-agonists, thiazide diuretics, and narcotics and stimulants in urine. To enable the simultaneous isolation of all the compounds of interest and the necessary purification of the resulting extracts, a generic extraction and hydrolysis procedure was combined with a solid-phase extraction modified for these groups of compounds. All 56 compounds are determined using positive electrospray ionisation with the exception of the thiazide diuretics for which the best sensitivity was obtained by using negative electrospray ionisation. The results show that, with the exception of clenhexyl, procaterol, and reproterol, all compounds can be detected below the respective minimum required performance level and the results for linearity, repeatability, within-lab reproducibility, and accuracy show that the method can be used for quantitative screening. If qualitative screening is sufficient the instrumental analysis may be limited to positive ionisation, because all analytes including the thiazides can be detected at the respective minimum required levels in the positive mode. The results show that the application of accurate-mass time-of-flight mass spectrometry in combination with generic extraction and purification procedures is suitable for unification and expansion of the window of screening methods of doping laboratories. Moreover, the full-scan accurate-mass data sets obtained still allow retrospective examination for emerging doping agents, without re-analyzing the samples.
Molecular toolbox for the identification of unknown genetically modified organisms.
Ruttink, Tom; Demeyer, Rolinde; Van Gulck, Elke; Van Droogenbroeck, Bart; Querci, Maddalena; Taverniers, Isabel; De Loose, Marc
2010-03-01
Competent laboratories monitor genetically modified organisms (GMOs) and products derived thereof in the food and feed chain in the framework of labeling and traceability legislation. In addition, screening is performed to detect the unauthorized presence of GMOs including asynchronously authorized GMOs or GMOs that are not officially registered for commercialization (unknown GMOs). Currently, unauthorized or unknown events are detected by screening blind samples for commonly used transgenic elements, such as p35S or t-nos. If (1) positive detection of such screening elements shows the presence of transgenic material and (2) all known GMOs are tested by event-specific methods but are not detected, then the presence of an unknown GMO is inferred. However, such evidence is indirect because it is based on negative observations and inconclusive because the procedure does not identify the causative event per se. In addition, detection of unknown events is hampered in products that also contain known authorized events. Here, we outline alternative approaches for analytical detection and GMO identification and develop new methods to complement the existing routine screening procedure. We developed a fluorescent anchor-polymerase chain reaction (PCR) method for the identification of the sequences flanking the p35S and t-nos screening elements. Thus, anchor-PCR fingerprinting allows the detection of unique discriminative signals per event. In addition, we established a collection of in silico calculated fingerprints of known events to support interpretation of experimentally generated anchor-PCR GM fingerprints of blind samples. Here, we first describe the molecular characterization of a novel GMO, which expresses recombinant human intrinsic factor in Arabidopsis thaliana. Next, we purposefully treated the novel GMO as a blind sample to simulate how the new methods lead to the molecular identification of a novel unknown event without prior knowledge of its transgene sequence. The results demonstrate that the new methods complement routine screening procedures by providing direct conclusive evidence and may also be useful to resolve masking of unknown events by known events.
Zulfiqar, Adnan; Morgan, Geraint; Turner, Nicholas W
2014-10-07
A method capable of screening for multiple steroids in urine has been developed, using a series of twelve structurally similar, and commercially relevant compounds as target analytes. A molecularly imprinted solid phase extraction clean-up step was used to make the sample suitable for injection onto a GC×GC-MS setup. Significant improvements compared to a commercially available C-18 material were observed. Each individual steroid was able to be separated and identified, using both the retention profile and diagnostic fragmentation ion monitoring abilities of the comprehensive chromatographic-mass spectrometry method. Effective LODs of between 11.7 and 27.0 pg were calculated for individual steroids, effectively equivalent to concentration levels of between 0.234 and 0.540 ng mL(-1) in urine, while the application of multiple screen was demonstrated using a 10 ng mL(-1) mixed sample. The nature of this study also removes the need for sample derivitisation which speeds up the screening process.
Screening of Chemical Dyes in Traditional Chinese Medicine by HPTLC-MS.
He, Fengyan; He, Yi; Zheng, Xiaowei; Wang, Ruizhong; Lu, Jing; Dai, Zhong; Ma, Shuangcheng
2018-05-01
It has been uncovered that chemical dyes are illegally used in traditional Chinese medicines to brighten color and cover up inferiority, which threaten the safety of patients. In the present study, an HPTLC-MS method was developed for the effective screening of 11 chemical dyes (Sudan I, II, III, and IV; 808 Scarlet; Sudan Red 7B; malachite green; Basic Orange 2; auramine; Orange II; and erythrosine) in traditional Chinese medicine (TCM) raw materials and Chinese patent medicines. Firstly, unwashed HPTLC plates were chosen by comparing the background signals of the TLC plates used directly and prewashed with analytical grade and HPLC grade solvents. Twice developments were conducted to isolate chemical dyes of different polarity. Possible adulterants were preliminarily identified by comparing Rf values and in situ UV-Vis spectra with those of the references. Further confirmation was conducted by tandem MS analysis via an elution head-based TLC-MS interface. Sudan I and IV, 808 Scarlet, and Orange II were successfully detected in eight batches of TCM. The proposed method could be applied as a reliable technology for the screening of chemical dyes in TCM.
An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.
Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu
2015-10-07
This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.
Jia, Wei; Shi, Lin; Chu, Xiaogang; Chang, James; Chen, Ying; Zhang, Feng
2018-10-01
An analytical method for the non-target screening of macrolides and metabolites in bass (Lateolabrax) was developed using an automated on-line extraction procedure followed by ultrahigh-performance liquid chromatography coupled to electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC Q-Orbitrap). The estimated performance characteristics were satisfied, complying with the requirements of the guidelines specified in European Commission Decision 2002/657/EC. The decision limit ranged from 0.12 μg kg -1 to 3.61 μg kg -1 , and detection capability ranged between 0.20 μg kg -1 and 6.02 μg kg -1 . Precision in terms of relative standard deviation (RSD) was under 14% for all compounds, and the extraction recoveries ranged from 81% to 107%. Finally, the method was applied to ten different commercially important bass species and confirmed the presence of ten macrolides and metabolites. Five non-target compounds of robenidine, lincomycin hydrochloride, thiacloprid, fenbendazole, and thiabendazole were elucidated in the untargeted screening. Copyright © 2018 Elsevier Ltd. All rights reserved.
Tang, Hubert Po-On; Ho, Clare; Lai, Shirley Sau-Ling
2006-01-01
A rapid qualitative method using on-line column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for screening 13 target veterinary drugs: four macrolides - erythromycin A, josamycin (leucomycin A3), kitasamycin (leucomycin A5), and tylosin A; six (fluoro)quinolones - ciprofloxacin, danofloxacin, enrofloxacin, flumequine, oxolinic acid, and sarafloxacin; and lincomycin, virginiamycin M1, and trimethoprim in different animal muscles. Clindamycin, norfloxacin, nalidixic acid, oleandomycin, ormetoprim, and roxithromycin were used as the internal standards. After simple deproteination and analyte extraction of muscle samples using acetonitrile, the supernatant was subjected to on-line cleanup and direct analysis by LC/MS/MS. On-line cleanup with an extraction cartridge packed with hydrophilic-hydrophobic polymer sorbent followed by fast LC using a short C18 column resulted in a total analysis cycle of 6 min for 19 drugs. This screening method considerably reduced the time and the cost for the quantitative and confirmatory analyses. The application of a control point approach was also introduced and explained. Copyright (c) 2006 John Wiley & Sons, Ltd.
Bang, Hae In; Jang, Mi Ae; Lee, Yong Wha
2017-11-01
The demand for rapid and broad clinical toxicology screens is on the rise. Recently, a new rapid toxicology screening test, the Triage TOX Drug Screen (Alere Inc., USA), which can simultaneously detect 11 drugs of abuse and therapeutic drugs with an instrument-read cartridge, was developed. In the present study, we evaluated the efficacy of this new on-site immunoassay using 105 urine specimens; the results were compared with those obtained by using ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-TMS). Precision was evaluated according to the CLSI EP12-A2 for analyte concentrations near the cutoff, including C₅₀ and±30% of C₅₀, for each drug using standard materials. The C₅₀ specimens yielded 35-65% positive results and the±30% concentration range of all evaluated drugs encompassed the C₅-C₉₅ interval. The overall percent agreement of the Triage TOX Drug Screen was 92.4-100% compared with UPLC-TMS; however, the Triage TOX Drug Screen results showed some discordant cases including acetaminophen, amphetamine, benzodiazepine, opiates, and tricyclic antidepressants. The overall performance of the Triage TOX Drug Screen assay was comparable to that of UPLC-TMS for screening of drug intoxication in hospitals. This assay could constitute a useful screening method for drugs of abuse and therapeutic drugs in urine. © The Korean Society for Laboratory Medicine.
Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M
2012-02-01
A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.
Gerace, E.; Salomone, A.; Abbadessa, G.; Racca, S.; Vincenti, M.
2011-01-01
A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. PMID:29403714
Slavkin, H C; Fox, C H; Meyer, D M
2011-10-01
Oral fluid-based (salivary) tests have the potential to create practical, point-of-care clinical instruments that are convenient, practical, and comfortable to use in dentistry and medicine. Currently, there are no simple, accurate, and inexpensive sampling, screening, or detection methods to support definitive diagnostic platforms across dental and medical disciplines. Though the benefits from advancing screening and detection technologies seem eminent, analytical, chemical, molecular, genetic, and protein markers are still under development. Clinical applications in patient care must be validated independently to ensure that they are clinically accurate, reliable, precise, and uniformly consistent for screening and detecting specific diseases or conditions. As technology designed to improve patient care through risk assessment, prevention, and disease management is transferred into clinical practice, dentistry may need to reassess its role in general health care. © International & American Associations for Dental Research
Rationally reduced libraries for combinatorial pathway optimization minimizing experimental effort.
Jeschek, Markus; Gerngross, Daniel; Panke, Sven
2016-03-31
Rational flux design in metabolic engineering approaches remains difficult since important pathway information is frequently not available. Therefore empirical methods are applied that randomly change absolute and relative pathway enzyme levels and subsequently screen for variants with improved performance. However, screening is often limited on the analytical side, generating a strong incentive to construct small but smart libraries. Here we introduce RedLibs (Reduced Libraries), an algorithm that allows for the rational design of smart combinatorial libraries for pathway optimization thereby minimizing the use of experimental resources. We demonstrate the utility of RedLibs for the design of ribosome-binding site libraries by in silico and in vivo screening with fluorescent proteins and perform a simple two-step optimization of the product selectivity in the branched multistep pathway for violacein biosynthesis, indicating a general applicability for the algorithm and the proposed heuristics. We expect that RedLibs will substantially simplify the refactoring of synthetic metabolic pathways.
A closed form solution for constant flux pumping in a well under partial penetration condition
NASA Astrophysics Data System (ADS)
Yang, Shaw-Yang; Yeh, Hund-Der; Chiu, Pin-Yuan
2006-05-01
An analytical model for the constant flux pumping test is developed in a radial confined aquifer system with a partially penetrating well. The Laplace domain solution is derived by the application of the Laplace transforms with respect to time and the finite Fourier cosine transforms with respect to the vertical coordinates. A time domain solution is obtained using the inverse Laplace transforms, convolution theorem, and Bromwich integral method. The effect of partial penetration is apparent if the test well is completed with a short screen. An aquifer thickness 100 times larger than the screen length of the well can be considered as infinite. This solution can be used to investigate the effects of screen length and location on the drawdown distribution in a radial confined aquifer system and to produce type curves for the estimation of aquifer parameters with field pumping drawdown data.
NASA Astrophysics Data System (ADS)
Pécoul, S.; Heuraux, S.; Koch, R.; Leclert, G.
2002-07-01
A realistic modeling of ICRH antennas requires the knowledge of the antenna currents. The code ICANT determines self-consistently these currents and, as a byproduct, the electrical characteristics of the antenna (radiated power, propagation constants on straps, frequency response, … ). The formalism allows for the description of three-dimensional antenna elements (for instance, finite size thick screen blades). The results obtained for various cases where analytical results are available are discussed. The resonances appearing in the spectrum and the occurrence of unphysical resonant modes are discussed. The capability of this self-consistent method is illustrated by a number of examples, e.g., fully conducting thin or thick screen bars leading to magnetic shielding effects, frequency response and resonances of an end-tuned antenna, field distributions in front of a Tore-Supra type antenna with tilted screen blades.
NASA Astrophysics Data System (ADS)
Campagnoli, Anna; Dell'Orto, Vittorio; Savoini, Giovanni; Cheli, Federica
2009-05-01
Mycotoxins represent an heterogeneous group of toxic compounds from fungi metabolism. Due to the frequent occurrence of mycotoxins in cereals commodities the develop of cost/effective screening methods represent an important topic to ensure food and feed safety. In the presented study a commercial electronic nose constituted by ten MOS (Metal Oxide Sensors) was applied to verify the possibility of discriminating between mycotoxins contaminated and non-contaminated cereals. The described analytical approach was able to discriminate contaminated and non-contaminated samples both in the case of aflatoxins infected maize and deoxynivalenol infected durum wheat samples. In the case of maize data two sensors from the array revealed a partial relation with the level of aflatoxins. These results could be promising for a further improvement of electronic nose application in order to develop a semi-quantitative screening approach to mycotoxins contamination.
Wang, Yuanze; van Oosterwijk, Niels; Ali, Ameena M; Adawy, Alaa; Anindya, Atsarina L; Dömling, Alexander S S; Groves, Matthew R
2017-08-24
Refolding of proteins derived from inclusion bodies is very promising as it can provide a reliable source of target proteins of high purity. However, inclusion body-based protein production is often limited by the lack of techniques for the detection of correctly refolded protein. Thus, the selection of the refolding conditions is mostly achieved using trial and error approaches and is thus a time-consuming process. In this study, we use the latest developments in the differential scanning fluorimetry guided refolding approach as an analytical method to detect correctly refolded protein. We describe a systematic buffer screen that contains a 96-well primary pH-refolding screen in conjunction with a secondary additive screen. Our research demonstrates that this approach could be applied for determining refolding conditions for several proteins. In addition, it revealed which "helper" molecules, such as arginine and additives are essential. Four different proteins: HA-RBD, MDM2, IL-17A and PD-L1 were used to validate our refolding approach. Our systematic protocol evaluates the impact of the "helper" molecules, the pH, buffer system and time on the protein refolding process in a high-throughput fashion. Finally, we demonstrate that refolding time and a secondary thermal shift assay buffer screen are critical factors for improving refolding efficiency.
Long, Stephen E; Catron, Brittany L; Boggs, Ashley Sp; Tai, Susan Sc; Wise, Stephen A
2016-09-01
The use of urinary iodine as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in urine. Likewise, the use of dietary iodine intake as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in dietary sources, including foods and dietary supplements. Similarly, the use of specific serum biomarkers of thyroid function to screen for both iodine deficiency and iodine excess relies in part on the accuracy of the analytical measurement of those biomarkers. The National Institute of Standards and Technology has been working with the NIH Office of Dietary Supplements for several years to develop higher-order reference measurement procedures and Standard Reference Materials to support the validation of new routine analytical methods for iodine in foods and dietary supplements, for urinary iodine, and for several serum biomarkers of thyroid function including thyroid-stimulating hormone, thyroglobulin, total and free thyroxine, and total and free triiodothyronine. These materials and methods have the potential to improve the assessment of iodine status and thyroid function in observational studies and clinical trials, thereby promoting public health efforts related to iodine nutrition. © 2016 American Society for Nutrition.
Multiple Reaction Monitoring Profiling to Assess Compliance with an Almond Consumption Intervention
Mattes, Richard D
2017-01-01
Abstract Background: Almonds are extremely rich sources of lipids and flavonoids, and their consumption is associated with several health benefits. However, there are no analytical methods available to document compliance with prescribed or self-reported chronic almond consumption. Objective: The aim was to use an analytical approach that identifies metabolic profiles associated with long-term almond consumption to ascertain compliance with prescribed consumption. Methods: A multiple reaction monitoring (MRM)–profiling strategy was designed to isolate metabolic changes in erythrocytes after 12 wk of almond consumption. MRM-profiling data acquisition and analysis involve performing separate discovery and screening steps to detect molecular features related to metabolic changes between experimental groups. Samples used for this research were erythrocytes recovered at baseline, after 12 wk of almond consumption (W12-almond group), and after 12 wk of a nut-free diet (W12-control group). For the MRM-profiling discovery step, representative samples (pools) of erythrocytes from individuals of all groups were interrogated by precursor ion and neutral loss scan experiments on the basis of previous knowledge of chemical functional groups present in the samples. The outputs of the discovery phase were methods used for the MRM-profiling screening phase to interrogate individual samples on the basis of fast-MRM measurements. In addition, we screened the literature for flavonoids identified in almond skins and included them for individual sample screening. Results: Of the 254 m/z values monitored, 5 ratios and combinations of specific ions with receiver operating characteristic curve AUCs >0.89 provided a sensitivity of 74.2% and a specificity of 90% for blind samples presented in the model. Eight of the 31 participants (25.8%) in the W12-almond group and 3 of the 30 (10%) participants in the W12-control group were misclassified by all 5 ratios. Ratios and combinations of specific transitions were mainly related to membrane lipids. Conclusion: The misclassifications observed as a result of ratio performance evaluation may indicate noncompliance as supported by the dietary intake data. The parent trial was registered at www.clinicaltrials.gov as NCT02360787.
Beliefs Underlying Messages of Anti-Cancer-Screening Websites in Japan: A Qualitative Analysis
Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro
2018-01-01
Background: Cancer screening rates are lower in Japan than in Western countries. Meanwhile, anti-cancer-screening activists take to the internet to spread their messages that cancer screening has little or no efficacy, poses substantial health risks such as side effects from radiation exposure, and that people should forgo cancer screening. We applied a qualitative approach to explore the beliefs underlying the messages of anti-cancer-screening websites, by focusing on perceived value the beliefs provided to those who held them. Methods: We conducted online searches using Google Japan and Yahoo! Japan, targeting websites we classified as “pro,” “anti,” or “neutral” depending on their claims. We applied a dual analytic approach- inductive thematic analysis and deductive interpretative analysis- to the textual data of the anti websites. Results: Of the 88 websites analyzed, five themes that correspond to beliefs were identified: destruction of common knowledge, denial of standard cancer control, education about right cancer control, education about hidden truths, and sense of superiority that only I know the truth. Authors of anti websites ascribed two values (“safety of people” and “self-esteem”) to their beliefs. Conclusion: The beliefs of authors of anti-cancer-screening websites were supposed to be strong. It would be better to target in cancer screening promotion not outright screening refusers but screening hesitant people who are more amenable to changing their attitudes toward screening. The possible means to persuade them were discussed. PMID:29479993
Abushareeda, Wadha; Lyris, Emmanouil; Kraiem, Suhail; Wahaibi, Aisha Al; Alyazidi, Sameera; Dbes, Najib; Lommen, Arjen; Nielen, Michel; Horvatovich, Peter L; Alsayrafi, Mohammed; Georgakopoulos, Costas
2017-09-15
This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World Antidoping Agency (WADA) enlists AAS as prohibited doping agents in sports, and our method has been developed to comply with the qualitative specifications of WADA to be applied for the detection of sports antidoping prohibited substances, mainly for AAS. The method also comprises of the quantitative analysis of the WADA's Athlete Biological Passport (ABP) endogenous steroidal parameters. The applied preparation of urine samples includes enzymatic hydrolysis for the cleavage of the Phase II glucuronide conjugates, generic liquid-liquid extraction and trimethylsilyl (TMS) derivatization steps. Tandem mass spectrometry (MS/MS) acquisition was applied on few selected ions to enhance the specificity and sensitivity of GC/TOF signal of few compounds. The full scan high resolution acquisition of analytical signal, for known and unknown TMS derivatives of AAS provides the antidoping system with a new analytical tool for the detection designer drugs and novel metabolites, which prolongs the AAS detection, after electronic data files' reprocessing. The current method is complementary to the respective liquid chromatography coupled to mass spectrometry (LC/MS) methodology widely used to detect prohibited molecules in sport, which cannot be efficiently ionized with atmospheric pressure ionization interface. Copyright © 2017 Elsevier B.V. All rights reserved.
Eichbaum, Kathrin; Brinkmann, Markus; Buchinger, Sebastian; Reifferscheid, Georg; Hecker, Markus; Giesy, John P; Engwall, Magnus; van Bavel, Bert; Hollert, Henner
2014-07-15
Use of in vitro assays as screening tool to characterize contamination of a variety of environmental matrices has become an increasingly popular and powerful toolbox in the field of environmental toxicology. While bioassays cannot entirely substitute analytical methods such as gas chromatography-mass spectrometry (GC-MS), the increasing improvement of cell lines and standardization of bioassay procedures enhance their utility as bioanalytical pre-screening tests prior to more targeted chemical analytical investigations. Dioxin-receptor-based assays provide a holistic characterization of exposure to dioxin-like compounds (DLCs) by integrating their overall toxic potential, including potentials of unknown DLCs not detectable via e.g. GC-MS. Hence, they provide important additional information with respect to environmental risk assessment of DLCs. This review summarizes different in vitro bioassay applications for detection of DLCs and considers the comparability of bioassay and chemical analytically derived toxicity equivalents (TEQs) of different approaches and various matrices. These range from complex samples such as sediments through single reference to compound mixtures. A summary of bioassay derived detection limits (LODs) showed a number of current bioassays to be equally sensitive as chemical methodologies, but moreover revealed that most of the bioanalytical studies conducted to date did not report their LODs, which represents a limitation with regard to low potency samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhou, Guisheng; Wang, Mengyue; Li, Yang; Peng, Ying; Li, Xiaobo
2015-08-01
In the present study, a new strategy based on chemical analysis and chemometrics methods was proposed for the comprehensive analysis and profiling of underivatized free amino acids (FAAs) and small peptides among various Luo-Han-Guo (LHG) samples. Firstly, the ultrasound-assisted extraction (UAE) parameters were optimized using Plackett-Burman (PB) screening and Box-Behnken designs (BBD), and the following optimal UAE conditions were obtained: ultrasound power of 280 W, extraction time of 43 min, and the solid-liquid ratio of 302 mL/g. Secondly, a rapid and sensitive analytical method was developed for simultaneous quantification of 24 FAAs and 3 active small peptides in LHG at trace levels using hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole linear ion-trap tandem mass spectrometry (HILIC-UHPLC-QTRAP(®)/MS(2)). The analytical method was validated by matrix effects, linearity, LODs, LOQs, precision, repeatability, stability, and recovery. Thirdly, the proposed optimal UAE conditions and analytical methods were applied to measurement of LHG samples. It was shown that LHG was rich in essential amino acids, which were beneficial nutrient substances for human health. Finally, based on the contents of the 27 analytes, the chemometrics methods of unsupervised principal component analysis (PCA) and supervised counter propagation artificial neural network (CP-ANN) were applied to differentiate and classify the 40 batches of LHG samples from different cultivated forms, regions, and varieties. As a result, these samples were mainly clustered into three clusters, which illustrated the cultivating disparity among the samples. In summary, the presented strategy had potential for the investigation of edible plants and agricultural products containing FAAs and small peptides.
The Potential Economic Value of Screening Hospital Admissions for Clostridium difficile
Bartsch, Sarah M.; Curry, Scott R.; Harrison, Lee H.; Lee, Bruce Y.
2012-01-01
Purpose Asymptomatic Clostridium difficile carriage has a prevalence reported as high as 51% to 85%; with up to 84% of incident hospital-acquired infections linked to carriers. Accurately identifying carriers may limit the spread of Clostridium difficile. Methods Since new technology adoption depends heavily on its economic value, we developed a analytic simulation model to determine the cost-effectiveness screening hospital admissions for Clostridium difficile from the hospital and third party payer perspectives. Isolation precautions were applied to patients testing positive, preventing transmission. Sensitivity analyses varied Clostridium difficile colonization rate, infection probability among secondary cases, contact isolation compliance, and screening cost. Results Screening was cost-effective [i.e., incremental cost-effectiveness ratio (ICER) ≤$50,000/QALY] for every scenario tested; all ICER values ≤$256/QALY. Screening was economically dominant (i.e., saved costs and provided health benefits) with a ≥10.3% colonization rate and ≥5.88% infection probability when contact isolation compliance was ≥25% (hospital perspective). Under some conditions screening led to cost-savings per case averted (range: $53 to $272). Conclusion Clostridium difficile screening, coupled with isolation precautions, may be a cost-effective intervention to hospitals and third party payers, based on prevalence. Limiting Clostridium difficile transmission can reduce the number of infections, thereby reducing its economic burden to the healthcare system. PMID:22752150
Zacharis, Constantinos K; Vastardi, Elli
2018-02-20
In the research presented we report the development of a simple and robust liquid chromatographic method for the quantification of two genotoxic alkyl sulphonate impurities (namely methyl p-toluenesulfonate and isopropyl p-toluenesulfonate) in Aprepitant API substances using the Analytical Quality by Design (AQbD) approach. Following the steps of AQbD protocol, the selected critical method attributes (CMAs) were the separation criterions between the critical peak pairs, the analysis time and the peak efficiencies of the analytes. The critical method parameters (CMPs) included the flow rate, the gradient slope and the acetonitrile content at the first step of the gradient elution program. Multivariate experimental designs namely Plackett-Burman and Box-Behnken designs were conducted sequentially for factor screening and optimization of the method parameters. The optimal separation conditions were estimated using the desirability function. The method was fully validated in the range of 10-200% of the target concentration limit of the analytes using the "total error" approach. Accuracy profiles - a graphical decision making tool - were constructed using the results of the validation procedures. The β-expectation tolerance intervals did not exceed the acceptance criteria of±10%, meaning that 95% of future results will be included in the defined bias limits. The relative bias ranged between - 1.3-3.8% for both analytes, while the RSD values for repeatability and intermediate precision were less than 1.9% in all cases. The achieved limit of detection (LOD) and the limit of quantification (LOQ) were adequate for the specific purpose and found to be 0.02% (corresponding to 48μgg -1 in sample) for both methyl and isopropyl p-toluenesulfonate. As proof-of-concept, the validated method was successfully applied in the analysis of several Aprepitant batches indicating that this methodology could be used for routine quality control analyses. Copyright © 2017 Elsevier B.V. All rights reserved.
The Ethics of Using Learning Analytics to Categorize Students on Risk
ERIC Educational Resources Information Center
Scholes, Vanessa
2016-01-01
There are good reasons for higher education institutions to use learning analytics to risk-screen students. Institutions can use learning analytics to better predict which students are at greater risk of dropping out or failing, and use the statistics to treat "risky" students differently. This paper analyses this practice using…
Schwaighofer, Andreas; Kuligowski, Julia; Quintás, Guillermo; Mayer, Helmut K; Lendl, Bernhard
2018-06-30
Analysis of proteins in bovine milk is usually tackled by time-consuming analytical approaches involving wet-chemical, multi-step sample clean-up procedures. The use of external cavity-quantum cascade laser (EC-QCL) based IR spectroscopy was evaluated as an alternative screening tool for direct and simultaneous quantification of individual proteins (i.e. casein and β-lactoglobulin) and total protein content in commercial bovine milk samples. Mid-IR spectra of protein standard mixtures were used for building partial least squares (PLS) regression models. A sample set comprising different milk types (pasteurized; differently processed extended shelf life, ESL; ultra-high temperature, UHT) was analysed and results were compared to reference methods. Concentration values of the QCL-IR spectroscopy approach obtained within several minutes are in good agreement with reference methods involving multiple sample preparation steps. The potential application as a fast screening method for estimating the heat load applied to liquid milk is demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sun, Meng; Ren, Jing; Du, Hui; Zhang, Yanmin; Zhang, Jie; Wang, Sicen; He, Langchong
2010-10-15
We have developed an online analytical method that combines A431 cell membrane chromatography (A431/CMC) with high performance liquid chromatography and mass spectrometry (LC/MS) for identifying active components from Radix Caulophylli acting on human EGFR. Retention fractions on A431/CMC model were captured onto an enrichment column and the components were directly analyzed by combining a 10-port column switcher with an LC/MS system for separation and preliminary identification. Using Sorafenib tosylate as a positive control, taspine and caulophine from Radix Caulophylli were identified as the active molecules which could act on the EGFR. This A431/CMC-online-LC/MS method can be applied for screening active components acting on EGFR from traditional Chinese medicines exemplified by Radix Caulophylli and will be of great utility in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2010 Elsevier B.V. All rights reserved.
Remote screening and direct control of the bacterial infection of gardens
NASA Astrophysics Data System (ADS)
Starodub, Nickolaj F.; Shavanova, Kateryna E.; Son'ko, Roman V.
2014-10-01
In last time gardens are often at the dangerous of viruses and bacteria infections. To preserve not only the coming harvest, but, in generally, to provide stability and growing horticultures the development of new generation of the analytical techniques for remote express screening vegetative state arrays and direct control of the appropriate infection if appearance of its maybe expected on the basis of previous surveys are very actually and important. For continuous monitoring we propose the application of the complex of the optical analytical devices as "Floratest" and "Plasmatest" (both produced in Ukraine) which is able to control step by step general situation with vegetable state and verify concrete situation with infection. General screening is accomplished on the control of the intensity of chlorophyll induction (IChF), namely, registration of so called Kautsky curve which testifies about physiological mechanisms of energy generation, accumulation and effective ways of its realization in cells. The measuring may be done by direct way on the number of individual vegetables and remote screening of massive with transferring registered signal direct in the laboratory. Next step of control connected with the application of the surface plasmon resonance (SPR) based immune biosensor which is able to determine concrete bacteria (for example, Erwinia amilovora) with the limit detection about 0.2 μg/ml, the overall time of the analysis within 30 min (5 min of the duration of one measurement). The traditional ELISA-method showed the sensitivity to this pathogen about 0.5 μg/ml, overall time of the analysis several hours and obligatory using additional expensive reagents.
Jiang, Xiao-Dan; Li, Guang-Yu; Dong, Zhen; Zhu, Dong-Dong
2011-01-01
Skin-prick testing (SPT) is the most common screening method for allergy evaluation. The detection of serum-specific immunoglobulin E (sIgE) is also commonly used. The sensitivity and specificity of these testing methods may vary due to type of causative allergen and type of allergic manifestation. The purpose of this study was to evaluate the correlation between two methods of measuring sIgE (AllergyScreen [Mediwiss Analytic GmbH, Moers, Germany] and ImmunoCAP [Pharmacia, Uppsala, Sweden]) and SPT for the diagnosis of allergic rhinitis (AR). All 216 patients who were referred to the allergist for suspected AR from June to October 2009 had SPT and the two serological tests. One hundred fifty-eight patients had a positive clinical history and a related positive SPT. The SPT was used as reference standard, and we selected three allergens (Dermatophagoides pteronyssinus, mugwort, and ragweed), which were common in fall in northeast China, to analyze the correlation of the two serum tests and SPT. Compared with the SPT, the diagnostic indexes (accuracy, sensitivity and specificity) of the AllergyScreen system and the ImmunoCAP system were 0.819 versus 0.810, 0.780 versus 0.872, and 0.862 versus 0.741, respectively. The accuracy was similar between the two systems (p > 0.05). The ImmunoCAP system method had a higher sensitivity (p < 0.01). The AllergyScreen system had a higher specificity (p < 0.01). These data support that the AllergyScreen system and ImmunoCAP system can identify potentially significant allergens in the diagnosis of AR in patients from northeastern China.
Loren, Bradley P.; Wleklinski, Michael; Koswara, Andy; Yammine, Kathryn; Hu, Yanyang
2017-01-01
A highly integrated approach to the development of a process for the continuous synthesis and purification of diphenhydramine is reported. Mass spectrometry (MS) is utilized throughout the system for on-line reaction monitoring, off-line yield quantitation, and as a reaction screening module that exploits reaction acceleration in charged microdroplets for high throughput route screening. This effort has enabled the discovery and optimization of multiple routes to diphenhydramine in glass microreactors using MS as a process analytical tool (PAT). The ability to rapidly screen conditions in charged microdroplets was used to guide optimization of the process in a microfluidic reactor. A quantitative MS method was developed and used to measure the reaction kinetics. Integration of the continuous-flow reactor/on-line MS methodology with a miniaturized crystallization platform for continuous reaction monitoring and controlled crystallization of diphenhydramine was also achieved. Our findings suggest a robust approach for the continuous manufacture of pharmaceutical drug products, exemplified in the particular case of diphenhydramine, and optimized for efficiency and crystal size, and guided by real-time analytics to produce the agent in a form that is readily adapted to continuous synthesis. PMID:28979759
Dolan, James G.; Boohaker, Emily; Allison, Jeroan; Imperiale, Thomas F.
2013-01-01
Background Current US colorectal cancer screening guidelines that call for shared decision making regarding the choice among several recommended screening options are difficult to implement. Multi-criteria decision analysis (MCDA) is an established methodology well suited for supporting shared decision making. Our study goal was to determine if a streamlined form of MCDA using rank order based judgments can accurately assess patients’ colorectal cancer screening priorities. Methods We converted priorities for four decision criteria and three sub-criteria regarding colorectal cancer screening obtained from 484 average risk patients using the Analytic Hierarchy Process (AHP) in a prior study into rank order-based priorities using rank order centroids. We compared the two sets of priorities using Spearman rank correlation and non-parametric Bland-Altman limits of agreement analysis. We assessed the differential impact of using the rank order-based versus the AHP-based priorities on the results of a full MCDA comparing three currently recommended colorectal cancer screening strategies. Generalizability of the results was assessed using Monte Carlo simulation. Results Correlations between the two sets of priorities for the seven criteria ranged from 0.55 to 0.92. The proportions of absolute differences between rank order-based and AHP-based priorities that were more than ± 0.15 ranged from 1% to 16%. Differences in the full MCDA results were minimal and the relative rankings of the three screening options were identical more than 88% of the time. The Monte Carlo simulation results were similar. Conclusion Rank order-based MCDA could be a simple, practical way to guide individual decisions and assess population decision priorities regarding colorectal cancer screening strategies. Additional research is warranted to further explore the use of these methods for promoting shared decision making. PMID:24300851
Turnipseed, Sherri B; Storey, Joseph M; Lohne, Jack J; Andersen, Wendy C; Burger, Robert; Johnson, Aaron S; Madson, Mark R
2017-08-30
A screening method for veterinary drug residues in fish, shrimp, and eel using LC with a high-resolution MS instrument has been developed and validated. The method was optimized for over 70 test compounds representing a variety of veterinary drug classes. Tissues were extracted by vortex mixing with acetonitrile acidified with 2% acetic acid and 0.2% p-toluenesulfonic acid. A centrifuged portion of the extract was passed through a novel solid phase extraction cartridge designed to remove interfering matrix components from tissue extracts. The eluent was then evaporated and reconstituted for analysis. Data were collected with a quadrupole-Orbitrap high-resolution mass spectrometer using both nontargeted and targeted acquisition methods. Residues were detected on the basis of the exact mass of the precursor and a product ion along with isotope pattern and retention time matching. Semiquantitative data analysis compared MS 1 signal to a one-point extracted matrix standard at a target testing level. The test compounds were detected and identified in salmon, tilapia, catfish, shrimp, and eel extracts fortified at the target testing levels. Fish dosed with selected analytes and aquaculture samples previously found to contain residues were also analyzed. The screening method can be expanded to monitor for an additional >260 veterinary drugs on the basis of exact mass measurements and retention times.
Exact solution for the Poisson field in a semi-infinite strip.
Cohen, Yossi; Rothman, Daniel H
2017-04-01
The Poisson equation is associated with many physical processes. Yet exact analytic solutions for the two-dimensional Poisson field are scarce. Here we derive an analytic solution for the Poisson equation with constant forcing in a semi-infinite strip. We provide a method that can be used to solve the field in other intricate geometries. We show that the Poisson flux reveals an inverse square-root singularity at a tip of a slit, and identify a characteristic length scale in which a small perturbation, in a form of a new slit, is screened by the field. We suggest that this length scale expresses itself as a characteristic spacing between tips in real Poisson networks that grow in response to fluxes at tips.
The development of high throughput biochemical screens could be useful to assess the broad spectrum of physiological effects of environmental toxicants. To explore the prospect of using a screen in an in vivo exposure scenario, we applied a commercially available multianalyte pro...
Liu, Jiao; Tian, Ji; Li, Jin; Azietaku, John Teye; Zhang, Bo-Li; Gao, Xiu-Mei; Chang, Yan-Xu
2016-07-01
An in-capillary 2, 2-diphenyl-1-picrylhydrazyl (DPPH)-CE-the DAD (in-capillary DPPH-CE-DAD) combined with reversed-electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β-CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p-coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH-CE-DAD method. Sensitivity was enhanced under reversed-electrode polarity stacking mode and 10- to 31-fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in-capillary DPPH-CE-DAD method combined with reversed-electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang
2016-09-06
Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.
Mass spectrometry-driven drug discovery for development of herbal medicine.
Zhang, Aihua; Sun, Hui; Wang, Xijun
2018-05-01
Herbal medicine (HM) has made a major contribution to the drug discovery process with regard to identifying products compounds. Currently, more attention has been focused on drug discovery from natural compounds of HM. Despite the rapid advancement of modern analytical techniques, drug discovery is still a difficult and lengthy process. Fortunately, mass spectrometry (MS) can provide us with useful structural information for drug discovery, has been recognized as a sensitive, rapid, and high-throughput technology for advancing drug discovery from HM in the post-genomic era. It is essential to develop an efficient, high-quality, high-throughput screening method integrated with an MS platform for early screening of candidate drug molecules from natural products. We have developed a new chinmedomics strategy reliant on MS that is capable of capturing the candidate molecules, facilitating their identification of novel chemical structures in the early phase; chinmedomics-guided natural product discovery based on MS may provide an effective tool that addresses challenges in early screening of effective constituents of herbs against disease. This critical review covers the use of MS with related techniques and methodologies for natural product discovery, biomarker identification, and determination of mechanisms of action. It also highlights high-throughput chinmedomics screening methods suitable for lead compound discovery illustrated by recent successes. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Gedge, M. R.
1979-01-01
Analytical models were developed to study the effect of flow contraction and screening on inflow distortions to identify qualitative design criteria. Results of the study are that: (1) static testing distortions are due to atmospheric turbulence, nacelle boundary layer, exhaust flow reingestion, flow over stand, ground plane, and engine casing; (2) flow contraction suppresses, initially, turbulent axial velocity distortions and magnifies turbulent transverse velocity distortions; (3) perforated plate and gauze screens suppress axial components of velocity distortions to a degree determined by the screen pressure loss coefficient; (4) honeycomb screen suppress transverse components of velocity distortions to a degree determined by the length to diameter ratio of the honeycomb; (5) acoustic transmission loss of perforated plate is controlled by the reactance of its acoustic impedance; (6) acoustic transmission loss of honeycomb screens is negligible; and (7) a model for the direction change due to a corner between honeycomb panels compares favorably with measured data.
Magalhães, Luana; de Oliveira, Arthur Henrique Cavalcante; de Souza Vasconcellos, Raphael; Mariotini-Moura, Christiane; de Cássia Firmino, Rafaela; Fietto, Juliana Lopes Rangel; Cardoso, Carmen Lúcia
2016-01-01
Nucleoside triphosphate diphosphohydrolase (NTPDase) is an enzyme belonging to the apyrase family that participates in the hydrolysis of the nucleosides di- and triphosphate to the corresponding nucleoside monophosphate. This enzyme underlies the virulence of parasites such as Leishmania. Recently, an NTPDase from Leishmania infantum (LicNTPDase-2) was cloned and expressed and has been considered as a new drug target for the treatment of leishmaniasis. With the intent of developing label-free online screening methodologies, LicNTPDase-2 was covalently immobilized onto a fused silica capillary tube in the present study to create an immobilized capillary enzyme reactor (ICER) based on LicNTPDase-2 (LicNTPDase-2-ICER). To perform the activity assays, a multidimensional chromatographic method was developed employing the LicNTPDase-2-ICER in the first dimension, and an analytical Ascentis C8 column was used in the second dimension to provide analytical separation of the substrates and products. The validated LicNTPDase-2-ICER method provided the following kinetic parameters of the immobilized enzyme: KM of 2.2 and 1.8mmolL(-1) for the ADP and ATP substrates, respectively. Suramin (1mmolL(-1)) was also shown to inhibit 32.9% of the enzymatic activity. The developed method is applicable to kinetic studies and enables the recognition of the ligands. Furthermore, a comparison of the values of LicNTPDase-2-ICER with those obtained with an LC method using free enzyme in solution showed that LicNTPDase-2-ICER-LC/UV was an accurate and reproducible method that enabled automated measurements for the rapid screening of ligands. Copyright © 2015 Elsevier B.V. All rights reserved.
Swortwood, Madeleine J; Boland, Diane M; DeCaprio, Anthony P
2013-02-01
Recently, clandestine drug lab operators have attempted to bypass controlled substances laws and regulations with "designer" compounds chemically and pharmacologically similar to controlled substances. For example, "bath salts" have erupted onto the scene as "legal highs" containing cathinone analogs that have produced severe side effects in users worldwide. These products have sparked concern among law enforcement agencies, and emergency bans have been placed on the sale of such items. Despite the increasing number of designer drugs available, there are few comprehensive screening techniques for their detection and quantification in biological specimens. The liquid chromatography triple quadrupole tandem mass spectrometry (LC-QQQ-MS/MS) method presented here encompasses over thirty important compounds within the phenethylamine, tryptamine, and piperazine designer drug classes. Analytes were determined by LC-QQQ-MS/MS in the multiple-reaction monitoring mode after mixed-mode solid-phase extraction. The bioanalytical method was fully validated according to recommended international guidelines. The assay was selective for all analytes with acceptable accuracy and precision. Limits of quantification were in the range of 1-10 ng/mL for each compound with limits of detection near 10 pg/mL. In order to evaluate its applicability in a forensic toxicological setting, the validated method was used to analyze post-mortem specimens from two cases that were suspected of containing designer drugs. The method was able to identify and quantify seven of these compounds at concentrations as low as 11 ng/mL. The method should have wide applicability for rapid screening of important new drugs of abuse at high sensitivity in both post- and ante-mortem forensic analysis.
Sireis, W; Rüster, B; Daiss, C; Hourfar, M K; Capalbo, G; Pfeiffer, H-U; Janetzko, K; Goebel, M; Kempf, V A J; Seifried, E; Schmidt, M
2011-10-01
The Paul-Ehrlich-Institute analysed all fatalities due to bacterial infections between 1997 and 2007. Thereafter, the platelet shelf life was reduced to a maximum of 4 days after blood donation because the majority of all cases of severe transfusion-transmitted bacterial infections occurred with day 5 platelets. The current study compares the analytical sensitivity and the diagnostic specificity of four rapid bacterial detection procedures. Nine transfusion-relevant bacterial strains were spiked in pooled platelets or apheresis platelets at a low concentration (10 CFU/bag). Samples were collected after day 3, day 4 and day 5 and investigated by four rapid bacterial detection methods (modified BacT/ALERT, Bactiflow, FACS method and 16s DNA PCR methods). Seven out of nine bacterial strains were adequately detected by BacT/ALERT, Bactiflow and PCR in apheresis platelets and pooled platelets after sample collection at day 3, day 4 and day 5. For three bacterial strains, analytical sensitivity was reduced for the FACS method. Two bacterial strains did not grow under the storage conditions in either pooled or apheresis platelets. A late sample collection on day 3, day 4 or day 5 after blood donation in combination with a rapid bacterial detection method offers a new opportunity to improve blood safety and reduce errors due to sampling., BacT/ALERT, Bactiflow or 16s ID-NAT are feasible for late bacterial screening in platelets may provide data which support the extension of platelet shelf life in Germany to 5 days. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.
Walorczyk, Stanisław; Drożdżyński, Dariusz; Kowalska, Jolanta; Remlein-Starosta, Dorota; Ziółkowski, Andrzej; Przewoźniak, Monika; Gnusowski, Bogusław
2013-08-15
A sensitive, accurate and reliable multiresidue method based on the application of gas chromatography-tandem quadrupole mass spectrometry (GC-QqQ-MS/MS) has been established for screening, identification and quantification of a large number of pesticide residues in produce. The method was accredited in compliance with PN-EN ISO/IEC 17025:2005 standard and it was operated under flexible scope as PB-11 method. The flexible scope of accreditation allowed for minor modifications and extension of the analytical scope while using the same analytical technique. During the years 2007-2010, the method was used for the purpose of verification of organic crop production by multiresidue analysis for the presence of pesticides. A total of 528 samples of differing matrices such as fruits, vegetables, cereals, plant leaves and other green parts were analysed, of which 4.4% samples contained pesticide residues above the threshold value of 0.01 mg/kg. A total of 20 different pesticide residues were determined in the samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
Websites in Japan: A Qualitative Analysis
Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro
2018-02-26
Background: Cancer screening rates are lower in Japan than in Western countries. Meanwhile, anti-cancer-screening activists take to the internet to spread their messages that cancer screening has little or no efficacy, poses substantial health risks such as side effects from radiation exposure, and that people should forgo cancer screening. We applied a qualitative approach to explore the beliefs underlying the messages of anti-cancer-screening websites, by focusing on perceived value the beliefs provided to those who held them. Methods: We conducted online searches using Google Japan and Yahoo! Japan, targeting websites we classified as “pro,” “anti,” or “neutral” depending on their claims. We applied a dual analytic approach- inductive thematic analysis and deductive interpretative analysis- to the textual data of the anti websites. Results: Of the 88 websites analyzed, five themes that correspond to beliefs were identified: destruction of common knowledge, denial of standard cancer control, education about right cancer control, education about hidden truths, and sense of superiority that only I know the truth. Authors of anti websites ascribed two values (“safety of people” and “self-esteem”) to their beliefs. Conclusion: The beliefs of authors of anti-cancer-screening websites were supposed to be strong. It would be better to target in cancer screening promotion not outright screening refusers but screening hesitant people who are more amenable to changing their attitudes toward screening. The possible means to persuade them were discussed. Creative Commons Attribution License
AHADI, H.; JOMEHRI, F.; RAHGOZAR, M.
2013-01-01
Summary Objectives. Despite advances in screening and treatment during past several Decades, cervical cancer remains a major health problem for Iranian women. Recent researches have focused on factors related to development of health behavior in an effort to design effective early interventions. The current study aimed to investigate the role of attachment styles on cervix cancer screening barriers among women of BandarAbbas-Iran. Methods. In an analytic-cross sectional study, 681 women aged 21-65 referring to health centers were selected randomly and after completing written informed consents were investigated by Revised Adult Attachment Scale (RAAS) (Collins and Read), Pap smear screening barriers and demographic data questionnaire. The data were analyzed by Pearson correlation coefficient, linear regressions and chi-square test. Results. The results showed significant association between attachment styles and screening barriers. There was a negative significant relation between secure attachment style and screening barriers and there was a positive significant association between insecure attachment style (anxiety and avoidant) and screening barriers. The regression analysis indicated that insecure attachment style (avoidant) were predictors of barriers to the Pap smear screening test in this regard. There was a significant association between age and residential area and participation in Pap smear test. Conclusions. Insecure attachment style is associated with hazardous risk behaviors and these results can be useful for health service providers in preventive planning of screening and identification of people susceptible to risk and the design of the intervention. PMID:24779284
Schmidt, Kathrin S; Mankertz, Joachim
2018-06-01
A sensitive and robust LC-MS/MS method allowing the rapid screening and confirmation of selective androgen receptor modulators in bovine urine was developed and successfully validated according to Commission Decision 2002/657/EC, chapter 3.1.3 'alternative validation', by applying a matrix-comprehensive in-house validation concept. The confirmation of the analytes in the validation samples was achieved both on the basis of the MRM ion ratios as laid down in Commission Decision 2002/657/EC and by comparison of their enhanced product ion (EPI) spectra with a reference mass spectral library by making use of the QTRAP technology. Here, in addition to the MRM survey scan, EPI spectra were generated in a data-dependent way according to an information-dependent acquisition criterion. Moreover, stability studies of the analytes in solution and in matrix according to an isochronous approach proved the stability of the analytes in solution and in matrix for at least the duration of the validation study. To identify factors that have a significant influence on the test method in routine analysis, a factorial effect analysis was performed. To this end, factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and different hydrolysis conditions) were systematically varied on two levels. The examination of the extent to which these factors influence the measurement results of the individual analytes showed that none of the validation factors exerts a significant influence on the measurement results.
Boussès, Christine; Ferey, Ludivine; Vedrines, Elodie; Gaudin, Karen
2015-11-10
An innovative combination of green chemistry and quality by design (QbD) approach is presented through the development of an UHPLC method for the analysis of the main degradation products of dextromethorphan hydrobromide. QbD strategy was integrated to the field of green analytical chemistry to improve method understanding while assuring quality and minimizing environmental impacts, and analyst exposure. This analytical method was thoroughly evaluated by applying risk assessment and multivariate analysis tools. After a scouting phase aimed at selecting a suitable stationary phase and an organic solvent in accordance with green chemistry principles, quality risk assessment tools were applied to determine the critical process parameters (CPPs). The effects of the CPPs on critical quality attributes (CQAs), i.e., resolutions, efficiencies, and solvent consumption were further evaluated by means of a screening design. A response surface methodology was then carried out to model CQAs as function of the selected CPPs and the optimal separation conditions were determined through a desirability analysis. Resulting contour plots enabled to establish the design space (DS) (method operable design region) where all CQAs fulfilled the requirements. An experimental validation of the DS proved that quality within the DS was guaranteed; therefore no more robustness study was required before the validation. Finally, this UHPLC method was validated using the concept of total error and was used to analyze a pharmaceutical drug product. Copyright © 2015 Elsevier B.V. All rights reserved.
Magnuson, Matthew; Campisano, Romy; Griggs, John; Fitz-James, Schatzi; Hall, Kathy; Mapp, Latisha; Mullins, Marissa; Nichols, Tonya; Shah, Sanjiv; Silvestri, Erin; Smith, Terry; Willison, Stuart; Ernst, Hiba
2014-11-01
Catastrophic incidents can generate a large number of samples of analytically diverse types, including forensic, clinical, environmental, food, and others. Environmental samples include water, wastewater, soil, air, urban building and infrastructure materials, and surface residue. Such samples may arise not only from contamination from the incident but also from the multitude of activities surrounding the response to the incident, including decontamination. This document summarizes a range of activities to help build laboratory capability in preparation for sample analysis following a catastrophic incident, including selection and development of fit-for-purpose analytical methods for chemical, biological, and radiological contaminants. Fit-for-purpose methods are those which have been selected to meet project specific data quality objectives. For example, methods could be fit for screening contamination in the early phases of investigation of contamination incidents because they are rapid and easily implemented, but those same methods may not be fit for the purpose of remediating the environment to acceptable levels when a more sensitive method is required. While the exact data quality objectives defining fitness-for-purpose can vary with each incident, a governing principle of the method selection and development process for environmental remediation and recovery is based on achieving high throughput while maintaining high quality analytical results. This paper illustrates the result of applying this principle, in the form of a compendium of analytical methods for contaminants of interest. The compendium is based on experience with actual incidents, where appropriate and available. This paper also discusses efforts aimed at adaptation of existing methods to increase fitness-for-purpose and development of innovative methods when necessary. The contaminants of interest are primarily those potentially released through catastrophes resulting from malicious activity. However, the same techniques discussed could also have application to catastrophes resulting from other incidents, such as natural disasters or industrial accidents. Further, the high sample throughput enabled by the techniques discussed could be employed for conventional environmental studies and compliance monitoring, potentially decreasing costs and/or increasing the quantity of data available to decision-makers. Published by Elsevier Ltd.
Sharma, Teenu; Khurana, Rajneet Kaur; Jain, Atul; Katare, O P; Singh, Bhupinder
2018-05-01
The current research work envisages an analytical quality by design-enabled development of a simple, rapid, sensitive, specific, robust and cost-effective stability-indicating reversed-phase high-performance liquid chromatographic method for determining stress-induced forced-degradation products of sorafenib tosylate (SFN). An Ishikawa fishbone diagram was constructed to embark upon analytical target profile and critical analytical attributes, i.e. peak area, theoretical plates, retention time and peak tailing. Factor screening using Taguchi orthogonal arrays and quality risk assessment studies carried out using failure mode effect analysis aided the selection of critical method parameters, i.e. mobile phase ratio and flow rate potentially affecting the chosen critical analytical attributes. Systematic optimization using response surface methodology of the chosen critical method parameters was carried out employing a two-factor-three-level-13-run, face-centered cubic design. A method operable design region was earmarked providing optimum method performance using numerical and graphical optimization. The optimum method employed a mobile phase composition consisting of acetonitrile and water (containing orthophosphoric acid, pH 4.1) at 65:35 v/v at a flow rate of 0.8 mL/min with UV detection at 265 nm using a C 18 column. Response surface methodology validation studies confirmed good efficiency and sensitivity of the developed method for analysis of SFN in mobile phase as well as in human plasma matrix. The forced degradation studies were conducted under different recommended stress conditions as per ICH Q1A (R2). Mass spectroscopy studies showed that SFN degrades in strongly acidic, alkaline and oxidative hydrolytic conditions at elevated temperature, while the drug was per se found to be photostable. Oxidative hydrolysis using 30% H 2 O 2 showed maximum degradation with products at retention times of 3.35, 3.65, 4.20 and 5.67 min. The absence of any significant change in the retention time of SFN and degradation products, formed under different stress conditions, ratified selectivity and specificity of the systematically developed method. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Guo, Baoshan; Lei, Cheng; Ito, Takuro; Yaxiaer, Yalikun; Kobayashi, Hirofumi; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke
2017-02-01
The development of reliable, sustainable, and economical sources of alternative fuels is an important, but challenging goal for the world. As an alternative to liquid fossil fuels, microalgal biofuel is expected to play a key role in reducing the detrimental effects of global warming since microalgae absorb atmospheric CO2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid contents and fail to characterize a diverse population of microalgal cells with single-cell resolution in a noninvasive and interference-free manner. Here we demonstrate high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy. In particular, we use Euglena gracilis - an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement) within lipid droplets. Our optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch phase-contrast microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase contents of every single cell at a high throughput of 10,000 cells/s. We characterize heterogeneous populations of E. gracilis cells under two different culture conditions to evaluate their lipid production efficiency. Our method holds promise as an effective analytical tool for microalgaebased biofuel production.
Hou, Xiaofang; Wang, Sicen; Hou, Jingjing; He, Langchong
2011-03-01
We describe here an analytical method of A431 cell membrane chromatography (A431/CMC) (CMC, cell membrane chromatography) combined with RPLC for recognition, separation, and identification of target components from traditional Chinese medicines (TCMs) Radix Caulophylli. The A431 cells with high expressed epidermal growth factor receptor (EGFR) were used to prepare the stationary phase in the CMC model. Retention fractions on the A431-CMC model were collected using an automated fraction collection and injection module (FC/I). Each fraction was analyzed by RPLC under the optimized conditions. Gefitinib and erlotinib were used as standard compounds to investigate the suitability and reliability of the A431 cell membrane chromatography-RPLC method prior to screening target component from Radix Caulophylli total alkaloids. The results indicated that caulophine and taspine were the target component acting on the epidermal growth factor receptor. This method could be an efficient way in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Laganà, Aldo
2012-12-14
A QuEChERS (Quick Easy Cheap Effective Rugged Safe)-like extraction method was developed for the simultaneous analysis of veterinary drugs and mycotoxins in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray (ESI) source. Various classes of antimicrobials (tetracyclines, ionophores, coccidiostats, penicillins, cephalosporins, fluoroquinolones, sulfonamides) and mycotoxins (enniatins, beauvericin, ochratoxins, aflatoxins) were considered for the development of this method. Particular attention was devoted to extraction optimization: different solvents (acetone, acetonitrile and methanol), different pH values and different sample to extracting volume ratios were tested and evaluated in terms of recovery, relative standard deviation (RSD) and ESI signal suppression due to matrix effect. Chromatographic and mass spectrometric conditions were optimized to obtain the best instrumental performances for most of the analytes. Quantitative analysis was performed by means of matrix-matched calibration, in a range that varied depending on the analyte and its established maximum limit, when there was one. Recoveries at 100 μg kg(-1) spiking level were >62% (3
Andersson, Maria; Stephanson, Nikolai; Ohman, Inger; Terzuoli, Tommy; Lindh, Jonatan D; Beck, Olof
2014-04-01
Opiates comprise a class of abused drugs that is of primary interest in clinical and forensic urine drug testing. Determination of heroin, codeine, or a multi-drug ingestion is complicated since both heroin and codeine can lead to urinary excretion of free and conjugated morphine. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers advantage over gas chromatography-mass spectrometry by simplifying sample preparation but increases the number of analytes. A method based on direct injection of five-fold diluted urine for confirmation of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide and 6-acetylmorphine was validated using LC-MS/MS in positive electrospray mode monitoring two transitions using selected reaction monitoring. The method was applied for the analysis of 3155 unknown urine samples which were positive for opiates in immunochemical screening. A linear response was observed for all compounds in the calibration curves covering more than three orders of magnitude. Cut off was set to 2 ng/ml for 6-acetylmorphine and 150 ng/ml for the other analytes. 6-Acetylmorphine was found to be effective (sensitivity 82%) in detecting samples as heroin intake. Morphine-3-glucuronide and codeine-6-glucuronide was the predominant components of total morphine and codeine, 84% and 93%, respectively. The authors have validated a robust LC-MS/MS method for rapid qualitative and quantitative analysis of opiates in urine. 6-Acetylmorphine has been demonstrated as a sensitive and important parameter for a heroin intake. A possible interpretation strategy to conclude the source of detected analytes was proposed. The method might be further developed by reducing the number of analytes to morphine-3-glucuronide, codeine-6-glucuronide and 6-acetylmorphine without compromising test performance. Copyright © 2013 John Wiley & Sons, Ltd.
Kenyon, Fiona; Rinaldi, Laura; McBean, Dave; Pepe, Paola; Bosco, Antonio; Melville, Lynsey; Devin, Leigh; Mitchell, Gillian; Ianniello, Davide; Charlier, Johannes; Vercruysse, Jozef; Cringoli, Giuseppe; Levecke, Bruno
2016-07-30
In small ruminants, faecal egg counts (FECs) and reduction in FECs (FECR) are the most common methods for the assessment of intensity of gastrointestinal (GI) nematodes infections and anthelmintic drug efficacy, respectively. The main limitation of these methods is the time and cost to conduct FECs on a representative number of individual animals. A cost-saving alternative would be to examine pooled faecal samples, however little is known regarding whether pooling can give representative results. In the present study, we compared the FECR results obtained by both an individual and a pooled examination strategy across different pool sizes and analytical sensitivity of the FEC techniques. A survey was conducted on 5 sheep farms in Scotland, where anthelmintic resistance is known to be widespread. Lambs were treated with fenbendazole (4 groups), levamisole (3 groups), ivermectin (3 groups) or moxidectin (1 group). For each group, individual faecal samples were collected from 20 animals, at baseline (D0) and 14 days after (D14) anthelmintic administration. Faecal samples were analyzed as pools of 3-5, 6-10, and 14-20 individual samples. Both individual and pooled samples were screened for GI strongyle and Nematodirus eggs using two FEC techniques with three different levels of analytical sensitivity, including Mini-FLOTAC (analytical sensitivity of 10 eggs per gram of faeces (EPG)) and McMaster (analytical sensitivity of 15 or 50 EPG).For both Mini-FLOTAC and McMaster (analytical sensitivity of 15 EPG), there was a perfect agreement in classifying the efficacy of the anthelmintic as 'normal', 'doubtful' or 'reduced' regardless of pool size. When using the McMaster method (analytical sensitivity of 50 EPG) anthelmintic efficacy was often falsely classified as 'normal' or assessment was not possible due to zero FECs at D0, and this became more pronounced when the pool size increased. In conclusion, pooling ovine faecal samples holds promise as a cost-saving and efficient strategy for assessing GI nematode FECR. However, for the assessment FECR one will need to consider the baseline FEC, pool size and analytical sensitivity of the method. Copyright © 2016. Published by Elsevier B.V.
General Unknown Screening by Ion Trap LC/MS/MS
2010-04-01
Subtitle 5 . Report Date April 2010 General Unknown Screening by Ion Trap LC/MS/MS 6 . Performing Organization Code 7. Author(s) 8... 5 Table 1: Analytical Data for Each of the...359 Compounds in the LC/MS/MS Library . . . . . . . . . . . 6 1 General Unknown ScreeninG by ion Trap lc/MS/MS INTrOduCTION The Federal Aviation
Using Organizational Network Analysis to Plan Cancer Screening Programs for Vulnerable Populations
Carothers, Bobbi J.; Lofters, Aisha K.
2014-01-01
Objectives. We examined relationships among organizations in a cancer screening network to inform the development of interventions to improve cancer screening for South Asians living in the Peel region of Ontario. Methods. From April to July 2012, we surveyed decision-makers, program managers, and program staff in 22 organizations in the South Asian cancer screening network in the Peel region. We used a network analytic approach to evaluate density (range = 0%–100%, number of ties among organizations in the network expressed as a percentage of all possible ties), centralization (range = 0–1, the extent of variability in centrality), and node characteristics for the communication, collaboration, and referral networks. Results. Density was similar across communication (15%), collaboration (17%), and referral (19%) networks. Centralization was greater in the collaboration network (0.30) than the communication network (0.24), and degree centralization was greater in the inbound (0.42) than the outbound (0.37) referral network. Diverse organizations were central to the networks. Conclusions. Certain organizations were unexpectedly important to the South Asian cancer screening network. Program planning was informed by identifying opportunities to strengthen linkages between key organizations and to leverage existing ties. PMID:24328613
Huesch, Marco D; Schetter, Susann; Segel, Joel; Chetlen, Alison
2017-08-01
The aim of this study was to understand the impact on screening mammography at our institution, comparing weekly utilization in the 2 years before and the 2 years after Ms Angelina Jolie disclosed in the New York Times on May 13, 2013, that she had had a prophylactic double mastectomy. All 48,110 consecutive screening mammograms conducted at our institution between May 16, 2011, and May 16, 2015, were selected from our electronic medical record system. We used interrupted time series statistical models and graphical methods on utilization data to understand utilization changes before and after Ms Jolie's news. The graphed trend of weekly screening mammogram utilization failed to show changes around the time of interest. Analytical models and statistical tests also failed to show a step change increase or acceleration of utilization around May 2013. However, graphical and time series analyses showed a flattening of utilization in the middle of 2014. In our well-powered analysis in a large regional breast imaging center, we found no support for the hypothesis that this celebrity news drove increased screening. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Inborn errors of metabolism and expanded newborn screening: review and update.
Mak, Chloe Miu; Lee, Han-Chih Hencher; Chan, Albert Yan-Wo; Lam, Ching-Wan
2013-11-01
Inborn errors of metabolism (IEM) are a phenotypically and genetically heterogeneous group of disorders caused by a defect in a metabolic pathway, leading to malfunctioning metabolism and/or the accumulation of toxic intermediate metabolites. To date, more than 1000 different IEM have been identified. While individually rare, the cumulative incidence has been shown to be upwards of 1 in 800. Clinical presentations are protean, complicating diagnostic pathways. IEM are present in all ethnic groups and across every age. Some IEM are amenable to treatment, with promising outcomes. However, high clinical suspicion alone is not sufficient to reduce morbidities and mortalities. In the last decade, due to the advent of tandem mass spectrometry, expanded newborn screening (NBS) has become a mandatory public health strategy in most developed and developing countries. The technology allows inexpensive simultaneous detection of more than 30 different metabolic disorders in one single blood spot specimen at a cost of about USD 10 per baby, with commendable analytical accuracy and precision. The sensitivity and specificity of this method can be up to 99% and 99.995%, respectively, for most amino acid disorders, organic acidemias, and fatty acid oxidation defects. Cost-effectiveness studies have confirmed that the savings achieved through the use of expanded NBS programs are significantly greater than the costs of implementation. The adverse effects of false positive results are negligible in view of the economic health benefits generated by expanded NBS and these could be minimized through increased education, better communication, and improved technologies. Local screening agencies should be given the autonomy to develop their screening programs in order to keep pace with international advancements. The development of biochemical genetics is closely linked with expanded NBS. With ongoing advancements in nanotechnology and molecular genomics, the field of biochemical genetics is still expanding rapidly. The potential of tandem mass spectrometry is extending to cover more disorders. Indeed, the use of genetic markers in T-cell receptor excision circles for severe combined immunodeficiency is one promising example. NBS represents the highest volume of genetic testing. It is more than a test and it warrants systematic healthcare service delivery across the pre-analytical, analytical, and post-analytical phases. There should be a comprehensive reporting system entailing genetic counselling as well as short-term and long-term follow-up. It is essential to integrate existing clinical IEM services with the expanded NBS program to enable close communication between the laboratory, clinicians, and allied health parties. In this review, we will discuss the history of IEM, its clinical presentations in children and adult patients, and its incidence among different ethnicities; the history and recent expansion of NBS, its cost-effectiveness, associated pros and cons, and the ethical issues that can arise; the analytical aspects of tandem mass spectrometry and post-analytical perspectives regarding result interpretation.
Effect of injection screen slot geometry on hydraulic conductivity tests
NASA Astrophysics Data System (ADS)
Klammler, Harald; Nemer, Bassel; Hatfield, Kirk
2014-04-01
Hydraulic conductivity and its spatial variability are important hydrogeological parameters and are typically determined through injection tests at different scales. For injection test interpretation, shape factors are required to account for injection screen geometry. Shape factors act as proportionality constants between hydraulic conductivity and observed ratios of injection flow rate and injection head at steady-state. Existing results for such shape factors assume either an ideal screen (i.e., ignoring effects of screen slot geometry) or infinite screen length (i.e., ignoring effects of screen extremes). In the present work, we investigate the combined effects of circumferential screen slot geometry and finite screen length on injection shape factors. This is done in terms of a screen entrance resistance by solving a steady-state potential flow mixed type boundary value problem in a homogeneous axi-symmetric flow domain using a semi-analytical solution approach. Results are compared to existing analytical solutions for circumferential and longitudinal slots on infinite screens, which are found to be identical. Based on an existing approximation, an expression is developed for a dimensionless screen entrance resistance of infinite screens, which is a function of the relative slot area only. For anisotropic conditions, e.g., when conductivity is smaller in the vertical direction than in the horizontal, screen entrance losses for circumferential slots increase, while they remain unaffected for longitudinal slots. This work is not concerned with investigating the effects of (possibly turbulent) head losses inside the injection device including the passage through the injection slots prior to entering the porous aquifer.
High-Density Droplet Microarray of Individually Addressable Electrochemical Cells.
Zhang, Huijie; Oellers, Tobias; Feng, Wenqian; Abdulazim, Tarik; Saw, En Ning; Ludwig, Alfred; Levkin, Pavel A; Plumeré, Nicolas
2017-06-06
Microarray technology has shown great potential for various types of high-throughput screening applications. The main read-out methods of most microarray platforms, however, are based on optical techniques, limiting the scope of potential applications of such powerful screening technology. Electrochemical methods possess numerous complementary advantages over optical detection methods, including its label-free nature, capability of quantitative monitoring of various reporter molecules, and the ability to not only detect but also address compositions of individual compartments. However, application of electrochemical methods for the purpose of high-throughput screening remains very limited. In this work, we develop a high-density individually addressable electrochemical droplet microarray (eDMA). The eDMA allows for the detection of redox-active reporter molecules irrespective of their electrochemical reversibility in individual nanoliter-sized droplets. Orthogonal band microelectrodes are arranged to form at their intersections an array of three-electrode systems for precise control of the applied potential, which enables direct read-out of the current related to analyte detection. The band microelectrode array is covered with a layer of permeable porous polymethacrylate functionalized with a highly hydrophobic-hydrophilic pattern, forming spatially separated nanoliter-sized droplets on top of each electrochemical cell. Electrochemical characterization of single droplets demonstrates that the underlying electrode system is accessible to redox-active molecules through the hydrophilic polymeric pattern and that the nonwettable hydrophobic boundaries can spatially separate neighboring cells effectively. The eDMA technology opens the possibility to combine the high-throughput biochemical or living cell screenings using the droplet microarray platform with the sequential electrochemical read-out of individual droplets.
Analytical methods for characterization of explosives-contaminated sites on U.S. Army installations
NASA Astrophysics Data System (ADS)
Jenkins, Thomas F.; Walsh, Marianne E.; Thorne, Philip G.
1995-10-01
The U.S. Army manufactures munitions at facilities throughout the United States. Many of these facilities are contaminated with residues of explosives from production, disposal of off- specification, and out-of-data munitions. The first step in remediating these sites is careful characterization. Currently sites are being characterized using a combination of on-site field screening and off-site laboratory analysis. Most of the contamination is associated with TNT (2,4,6-trinitrotoluene) and RDX (hexahydro-1,3,5-tri-nitro-1,3,5-triazine) and their manufacturing impurities and environmental transformation products. Both colorimetric and enzyme immunoassay-based field screening methods have been used successfully for on-site characterization. These methods have similar detection capabilities but differ in their selectivity. Although field screening is very cost-effective, laboratory analysis is still required to fully characterize a site. Laboratory analysis for explosives residues in the United States is generally conducted using high-performance liquid chromatography equipped with a UV detector. Air-dried soils are extracted with acetonitrile in an ultrasonic bath. Water is analyzed directly if detection limits in the range of 10 - 20 (mu) g/L are acceptable, or preconcentrated using either salting-out solvent extraction with acetonitrile or solid phase extraction.
Adaptation of High-Throughput Screening in Drug Discovery—Toxicological Screening Tests
Szymański, Paweł; Markowicz, Magdalena; Mikiciuk-Olasik, Elżbieta
2012-01-01
High-throughput screening (HTS) is one of the newest techniques used in drug design and may be applied in biological and chemical sciences. This method, due to utilization of robots, detectors and software that regulate the whole process, enables a series of analyses of chemical compounds to be conducted in a short time and the affinity of biological structures which is often related to toxicity to be defined. Since 2008 we have implemented the automation of this technique and as a consequence, the possibility to examine 100,000 compounds per day. The HTS method is more frequently utilized in conjunction with analytical techniques such as NMR or coupled methods e.g., LC-MS/MS. Series of studies enable the establishment of the rate of affinity for targets or the level of toxicity. Moreover, researches are conducted concerning conjugation of nanoparticles with drugs and the determination of the toxicity of such structures. For these purposes there are frequently used cell lines. Due to the miniaturization of all systems, it is possible to examine the compound’s toxicity having only 1–3 mg of this compound. Determination of cytotoxicity in this way leads to a significant decrease in the expenditure and to a reduction in the length of the study. PMID:22312262
Ismail, Sohal Y; Duerinckx, Nathalie; van der Knoop, Marieke M; Timmerman, Lotte; Weimar, Willem; Dobbels, Fabienne; Massey, Emma K; Busschbach, Jan J J V
2015-11-01
Across Europe, transplant centers vary in the content of the psychosocial evaluation for eligible living organ donors. To identify whether a common framework underlies this variation in this evaluation, we studied which psychosocial screening items are most commonly used and considered as most important in current psychosocial screening programs of living organ donors. A multivariate analytic method, concept mapping, was used to generate a visual representation of the "psychosocial" screening items of living kidney and liver donors. A list of 75 potential screening items was derived from a systematic literature review and sorted and rated for their importance and commonness by multidisciplinary affiliated health care professionals from across Europe. Results were discussed and fine-tuned during a consensus meeting. The analyses resulted in a 6-cluster solution. The following clusters on psychosocial screening items were identified, listed from most to least important: (1) personal resources, (2) motivation and decision making, (3) psychopathology, (4) social resources, (5) ethical and legal factors, and (6) information and risk processing. We provided a conceptual framework of the essential elements in psychosocial evaluation of living donors which can serve as a uniform basis for the selection of relevant psychosocial evaluation tools, which can be further tested in prospective studies.
A multiplex degenerate PCR analytical approach targeting to eight genes for screening GMOs.
Guo, Jinchao; Chen, Lili; Liu, Xin; Gao, Ying; Zhang, Dabing; Yang, Litao
2012-06-01
Currently, the detection methods with lower cost and higher throughput are the major trend in screening genetically modified (GM) food or feed before specific identification. In this study, we developed a quadruplex degenerate PCR screening approach for more than 90 approved GMO events. This assay is consisted of four PCR systems targeting on nine DNA sequences from eight trait genes widely introduced into GMOs, such as CP4-EPSPS derived from Acetobacterium tumefaciens sp. strain CP4, phosphinothricin acetyltransferase gene derived from Streptomyceshygroscopicus (bar) and Streptomyces viridochromogenes (pat), and Cry1Ab, Cry1Ac, Cry1A(b/c), mCry3A, and Cry3Bb1 derived from Bacillus thuringiensis. The quadruplex degenerate PCR assay offers high specificity and sensitivity with the absolute limit of detection (LOD) of approximate 80targetcopies. Furthermore, the applicability of the quadruplex PCR assay was confirmed by screening either several artificially prepared samples or samples of Grain Inspection, Packers and Stockyards Administration (GIPSA) proficiency program. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
El-Nour, K. M. A.; Salam, E. T. A.; Soliman, H. M.; Orabi, A. S.
2017-03-01
A new optical sensor was developed for rapid screening with high sensitivity for the existence of biogenic amines (BAs) in poultry meat samples. Gold nanoparticles (GNPs) with particle size 11-19 nm function as a fast and sensitive biosensor for detection of histamine resulting from bacterial decarboxylation of histidine as a spoilage marker for stored poultry meat. Upon reaction with histamine, the red color of the GNPs converted into deep blue. The appearance of blue color favorably coincides with the concentration of BAs that can induce symptoms of poisoning. This biosensor enables a semi-quantitative detection of analyte in real samples by eye-vision. Quality evaluation is carried out by measuring histamine and histidine using different analytical techniques such as UV-vis, FTIR, and fluorescence spectroscopy as well as TEM. A rapid quantitative readout of samples by UV-vis and fluorescence methods with standard instrumentation were proposed in a short time unlike chromatographic and electrophoretic methods. Sensitivity and limit of detection (LOD) of 6.59 × 10-4 and 0.6 μM, respectively, are determined for histamine as a spoilage marker with a correlation coefficient ( R 2) of 0.993.
ANALYTICAL TOOLS FOR GROUNDWATER POLLUTION ASSESSMENT
This paper deals with the development of analytical screening-exposure models (indices) and their potential application to regulate the use of hazardous chemicals and the design of groundwater buffer strips. The indices describe the leaching of solutes below the root zone (mass f...
Pyo, Jeung Hui; Hong, Sung Noh; Min, Byung-Hoon; Lee, Jun Haeng; Chang, Dong Kyung; Rhee, Poong-Lyul; Kim, Jae Jun; Choi, Sun Kyu; Jung, Sin-Ho; Son, Hee Jung; Kim, Young-Ho
2016-12-01
Rectal neuroendocrine tumor (NET) is the most common NET in Asia. The risk factors associated with rectal NETs are unclear because of the overall low incidence rate of these tumors and the associated difficulty in conducting large epidemiological studies on rare cases. The aim of this study was to exploit the benefits of big data analytics to assess the risk factors associated with rectal NET. A retrospective case-control study was conducted, including 102 patients with histologically confirmed rectal NETs and 52,583 healthy controls who underwent screening colonoscopy at the Center for Health Promotion of the Samsung Medical Center in Korea between January 2002 and December 2012. Information on different risk factors was collected and logistic regression analysis applied to identify predictive factors. Four factors were significantly associated with rectal NET: higher levels of cholesterol [odds ratio (OR) = 1.007, 95 % confidence interval (CI), 1.001-1.013, p = 0.016] and ferritin (OR = 1.502, 95 % CI, 1.167-1.935, p = 0.002), presence of metabolic syndrome (OR = 1.768, 95 % CI, 1.071-2.918, p = 0.026), and family history of cancer among first-degree relatives (OR = 1.664, 95 % CI, 1.019-2.718, p = 0.042). The findings of our study demonstrate the benefits of using big data analytics for research and clinical risk factor studies. Specifically, in this study, this analytical method was applied to identify higher levels of serum cholesterol and ferritin, metabolic syndrome, and family history of cancer as factors that may explain the increasing incidence and prevalence of rectal NET.
Comprehensive screening and quantification of veterinary drugs in milk using UPLC–ToF-MS
Rutgers, P.; Oosterink, E.; Lasaroms, J. J. P.; Peters, R. J. B.; van Rhijn, J. A.; Nielen, M. W. F.
2008-01-01
Ultra-performance liquid chromatography combined with time-of-flight mass spectrometry (UPLC–ToF-MS) has been used for screening and quantification of more than 100 veterinary drugs in milk. The veterinary drugs represent different classes including benzimidazoles, macrolides, penicillins, quinolones, sulphonamides, pyrimidines, tetracylines, nitroimidazoles, tranquillizers, ionophores, amphenicols and non-steroidal anti-inflammatory agents (NSAIDs). After protein precipitation, centrifugation and solid-phase extraction (SPE), the extracts were analysed by UPLC–ToF-MS. From the acquired full scan data the drug-specific ions were extracted for construction of the chromatograms and evaluation of the results. The analytical method was validated according to the EU guidelines (2002/657/EC) for a quantitative screening method. At the concentration level of interest (MRL level) the results for repeatability (%RSD < 20% for 86% of the compounds), reproducibility (%RSD < 40% for 96% of the compounds) and the accuracy (80–120% for 88% of the compounds) were satisfactory. Evaluation of the CCβ values and the linearity results demonstrates that the developed method shows adequate sensitivity and linearity to provide quantitative results. Furthermore, the method is accurate enough to differentiate between suspected and negative samples or drug concentrations below or above the MRL. A set of 100 samples of raw milk were screened for residues. No suspected (positive) results were obtained except for the included blind reference sample containing sulphamethazine (88 μg/l) that tested positive for this compound. UPLC–ToF-MS combines high resolution for both LC and MS with high mass accuracy which is very powerful for the multi-compound analysis of veterinary drugs. The technique seems to be powerful enough for the analysis of not only veterinary drugs but also organic contaminants like pesticides, mycotoxins and plant toxins in one single method. PMID:18491081
Lawson, A J; Bernstone, L; Hall, S K
2016-03-01
In dried blood spot analysis, punch location and variations in applied sample volume and haematocrit can produce different measured concentrations of analytes. We investigated the magnitude of these effects in newborn screening in the UK. Heparinized blood spiked with thyroid stimulating hormone (TSH), phenylalanine, tyrosine, leucine, methionine, octanoyl carnitine (C8), and immunoreactive trypsinogen (IRT) was spotted onto filter paper: (i) at a constant haematocrit of 50% at various volumes, and (ii) at a range of haematocrits using a constant volume. Subpunches (3.2 mm) of the dried blood spots were then analysed. Compared with a central punch from a 50 µL blood spot with 50% haematocrit, 10 µL spots can have significantly lower measured concentrations of all analytes, with decreases of 15% or more observed for leucine, methionine, phenylalanine, and tyrosine. Punching at the edge of a spot can increase measured concentrations up to 35%. Higher haematocrit decreased measured TSH and C8 yet increased amino acids and IRT by 15% compared with 50% haematocrit. Lower haematocrits had the opposite effect, but only with higher concentrations of some analytes. Differences in blood spot size, haematocrit and punch location substantially affect measured concentrations for analytes used in the UK newborn screening programme, and this could affect false positive and negative rates. To minimize analytical bias, these variables should be controlled or adjusted for where possible. © The Author(s) 2015.
Li, Juan; Yang, Yang; Huan, Huan; Li, Mingxiao; Xi, Beidou; Lv, Ningqing; Wu, Yi; Xie, Yiwen; Li, Xiang; Yang, Jinjin
2016-05-01
This paper presents a system for determining the evaluation and gradation indices of groundwater pollution intensity (GPI). Considering the characteristics of the vadose zone and pollution sources, the system decides which anti-seepage measures should be implemented at the contaminated site. The pollution sources hazards (PSH) and groundwater intrinsic vulnerability (GIV) are graded by the revised Nemerow Pollution Index and an improved DRTAS model, respectively. GPI is evaluated and graded by a double-sided multi-factor coupling model, which is constructed by the matrix method. The contaminated sites are categorized as prior, ordinary, or common sites. From the GPI results, we develop guiding principles for preventing and removing pollution sources, procedural interruption and remediation, and end treatment and monitoring. Thus, we can select appropriate prevention and control technologies (PCT). To screen the technological schemes and optimize the traditional analytical hierarchy process (AHP), we adopt the technique for order preference by the similarity to ideal solution (TOPSIS) method. Our GPI approach and PCT screening are applied to three types of pollution sites: the refuse dump of a rare earth mine development project (a potential pollution source), a chromium slag dump, and a landfill (existing pollution sources). These three sites are identified as ordinary, prior, and ordinary sites, respectively. The anti-seepage materials at the refuse dump should perform as effectively as a 1.5-m-thick clay bed. The chromium slag dump should be preferentially treated by soil flushing and in situ chemical remediation. The landfill should be treated by natural attenuation technology. The proposed PCT screening approach was compared with conventional screening methods results at the three sites and proved feasible and effective. The proposed method can provide technical support for the monitoring and management of groundwater pollution in China. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Gatto, Paolo; Lipparini, Filippo; Stamm, Benjamin
2017-12-01
The domain-decomposition (dd) paradigm, originally introduced for the conductor-like screening model, has been recently extended to the dielectric Polarizable Continuum Model (PCM), resulting in the ddPCM method. We present here a complete derivation of the analytical derivatives of the ddPCM energy with respect to the positions of the solute's atoms and discuss their efficient implementation. As it is the case for the energy, we observe a quadratic scaling, which is discussed and demonstrated with numerical tests.
Wang, Shu-Ping; Liu, Lei; Wang, Ling-Ling; Jiang, Peng; Zhang, Ji-Quan; Zhang, Wei-Dong; Liu, Run-Hui
2010-06-15
Based on the serum pharmacochemistry technique and high-performance liquid chromatography/diode-array detection (HPLC/DAD) coupled with electrospray tandem mass spectrometry (HPLC/ESI-MS/MS), a method for screening and analysis of the multiple absorbed bioactive components and metabolites of Jitai tablets (JTT) in orally dosed rat plasma was developed. Plasma was treated by methanol precipitation prior to liquid chromatography, and the separation was carried out on a Symmetry C(18) column, with a linear gradient (0.1% formic acid/water/acetonitrile). Mass spectra were acquired in negative and positive ion modes, respectively. As a result, 26 bioactive components originated from JTT and 5 metabolites were tentatively identified in orally dosed rat plasma by comparing their retention times and MS spectra with those of authentic standards and literature data. It is concluded that an effective and reliable analytical method was set up for screening the bioactive components of Chinese herbal medicine, which provided a meaningful basis for further pharmacology and active mechanism research of JTT. Copyright (c) 2010 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hennebert, Pierre, E-mail: pierre.hennebert@ineris.fr; Papin, Arnaud; Padox, Jean-Marie
Highlights: • Knowledge of wastes in substances will be necessary to assess HP1–HP15 hazard properties. • A new analytical protocol is proposed for this and tested by two service laboratories on 32 samples. • Sixty-three percentage of the samples have a satisfactory analytical balance between 90% and 110%. • Eighty-four percentage of the samples were classified identically (Seveso Directive) for their hazardousness by the two laboratories. • The method, in progress, is being normalized in France and is be proposed to CEN. - Abstract: The classification of waste as hazardous could soon be assessed in Europe using largely the hazardmore » properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC–MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of ‘pools’ of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved ‘mass’ during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved ‘pools’) should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter results. Despite discrepancies in some parameters, a satisfactory sum of estimated or measured concentrations (analytical balance) of 90% was reached for 20 samples (63% of the overall total) during this first test exercise, with identified reasons for most of the unsatisfactory results. Regular use of this protocol (which is now included in the French legislation) has enabled service laboratories to reach a 90% mass balance for nearly all the solid samples tested, and most of liquid samples (difficulties were caused in some samples from polymers in solution and vegetable oil). The protocol is submitted to French and European normalization bodies (AFNOR and CEN) and further improvements are awaited.« less
Santhiago, Murilo; Wydallis, John B.; Kubota, Lauro T.; Henry, Charles S.
2013-01-01
This work presents a simple, low cost method for creating microelectrodes for electrochemical paper-based analytical devices (ePADs). The microelectrodes were constructed by backfilling small holes made in polyester sheets using a CO2 laser etching system. To make electrical connections, the working electrodes were combined with silver screen-printed paper in a sandwich type two-electrode configuration. The devices were characterized using linear sweep voltammetry and the results are in good agreement with theoretical predictions for electrode size and shape. As a proof-of-concept, cysteine was measured using cobalt phthalocyanine as a redox mediator. The rate constant (kobs) for the chemical reaction between cysteine and the redox mediator was obtained by chronoamperometry and found to be on the order of 105 s−1 M−1. Using a microelectrode array, it was possible to reach a limit of detection of 4.8 μM for cysteine. The results show that carbon paste microelectrodes can be easily integrated with paper-based analytical devices. PMID:23581428
Santhiago, Murilo; Wydallis, John B; Kubota, Lauro T; Henry, Charles S
2013-05-21
This work presents a simple, low cost method for creating microelectrodes for electrochemical paper-based analytical devices (ePADs). The microelectrodes were constructed by backfilling small holes made in polyester sheets using a CO2 laser etching system. To make electrical connections, the working electrodes were combined with silver screen-printed paper in a sandwich type two-electrode configuration. The devices were characterized using linear sweep voltammetry, and the results are in good agreement with theoretical predictions for electrode size and shape. As a proof-of-concept, cysteine was measured using cobalt phthalocyanine as a redox mediator. The rate constant (k(obs)) for the chemical reaction between cysteine and the redox mediator was obtained by chronoamperometry and found to be on the order of 10(5) s(-1) M(-1). Using a microelectrode array, it was possible to reach a limit of detection of 4.8 μM for cysteine. The results show that carbon paste microelectrodes can be easily integrated with paper-based analytical devices.
Integrated quantification and identification of aldehydes and ketones in biological samples.
Siegel, David; Meinema, Anne C; Permentier, Hjalmar; Hopfgartner, Gérard; Bischoff, Rainer
2014-05-20
The identification of unknown compounds remains to be a bottleneck of mass spectrometry (MS)-based metabolomics screening experiments. Here, we present a novel approach which facilitates the identification and quantification of analytes containing aldehyde and ketone groups in biological samples by adding chemical information to MS data. Our strategy is based on rapid autosampler-in-needle-derivatization with p-toluenesulfonylhydrazine (TSH). The resulting TSH-hydrazones are separated by ultrahigh-performance liquid chromatography (UHPLC) and detected by electrospray ionization-quadrupole-time-of-flight (ESI-QqTOF) mass spectrometry using a SWATH (Sequential Window Acquisition of all Theoretical Fragment-Ion Spectra) data-independent high-resolution mass spectrometry (HR-MS) approach. Derivatization makes small, poorly ionizable or retained analytes amenable to reversed phase chromatography and electrospray ionization in both polarities. Negatively charged TSH-hydrazone ions furthermore show a simple and predictable fragmentation pattern upon collision induced dissociation, which enables the chemo-selective screening for unknown aldehydes and ketones via a signature fragment ion (m/z 155.0172). By means of SWATH, targeted and nontargeted application scenarios of the suggested derivatization route are enabled in the frame of a single UHPLC-ESI-QqTOF-HR-MS workflow. The method's ability to simultaneously quantify and identify molecules containing aldehyde and ketone groups is demonstrated using 61 target analytes from various compound classes and a (13)C labeled yeast matrix. The identification of unknowns in biological samples is detailed using the example of indole-3-acetaldehyde.
Aquatic concentrations of chemical analytes compared to ecotoxicity estimates
We describe screening level estimates of potential aquatic toxicity posed by 227 chemical analytes that were measured in 25 ambient water samples collected as part of a joint USGS/USEPA drinking water plant study. Measured concentrations were compared to biological effect concent...
Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone.
Harvey, Virginia L; Egerton, Victoria M; Chamberlain, Andrew T; Manning, Phillip L; Buckley, Michael
2016-01-01
Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six (14)C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated (14)C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 1(4)C analysis.
Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone
Harvey, Virginia L.; Egerton, Victoria M.; Chamberlain, Andrew T.; Manning, Phillip L.; Buckley, Michael
2016-01-01
Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six 14C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated 14C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 14C analysis. PMID:26938469
Real-Time Monitoring of Cellular Bioenergetics with a Multi-Analyte Screen-Printed Electrode
McKenzie, Jennifer R.; Cognata, Andrew C.; Davis, Anna N.; Wikswo, John P.; Cliffel, David E.
2016-01-01
Real-time monitoring of changes to cellular bioenergetics can provide new insights into mechanisms of action for disease and toxicity. This work describes the development of a multi-analyte screen-printed electrode for the detection of analytes central to cellular bioenergetics: glucose, lactate, oxygen, and pH. Platinum screen-printed electrodes were designed in-house and printed by Pine Research Instrumentation. Electrochemical plating techniques were used to form quasi-reference and pH electrodes. A Dimatix materials inkjet printer was used to deposit enzyme and polymer films to form sensors for glucose, lactate, and oxygen. These sensors were evaluated in bulk solution and microfluidic environments, and found to behave reproducibly and possess a lifetime of up to six weeks. Linear ranges and limits of detection for enzyme-based sensors were found to have an inverse relationship with enzyme loading, and iridium oxide pH sensors were found to have super-Nernstian responses. Preliminary measurements where the sensor was enclosed within a microfluidic channel with RAW 264.7 macrophages were performed to demonstrate the sensors’ capabilities for performing real-time microphysiometry measurements. PMID:26125545
Rousis, Nikolaos I; Bade, Richard; Bijlsma, Lubertus; Zuccato, Ettore; Sancho, Juan V; Hernandez, Felix; Castiglioni, Sara
2017-07-01
Assessing the presence of pesticides in environmental waters is particularly challenging because of the huge number of substances used which may end up in the environment. Furthermore, the occurrence of pesticide transformation products (TPs) and/or metabolites makes this task even harder. Most studies dealing with the determination of pesticides in water include only a small number of analytes and in many cases no TPs. The present study applied a screening method for the determination of a large number of pesticides and TPs in wastewater (WW) and surface water (SW) from Spain and Italy. Liquid chromatography coupled to high-resolution mass spectrometry (HRMS) was used to screen a database of 450 pesticides and TPs. Detection and identification were based on specific criteria, i.e. mass accuracy, fragmentation, and comparison of retention times when reference standards were available, or a retention time prediction model when standards were not available. Seventeen pesticides and TPs from different classes (fungicides, herbicides and insecticides) were found in WW in Italy and Spain, and twelve in SW. Generally, in both countries more compounds were detected in effluent WW than in influent WW, and in SW than WW. This might be due to the analytical sensitivity in the different matrices, but also to the presence of multiple sources of pollution. HRMS proved a good screening tool to determine a large number of substances in water and identify some priority compounds for further quantitative analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
Müller, Alexander; Schulz, Wolfgang; Ruck, Wolfgang K L; Weber, Walter H
2011-11-01
Non-target screening via high performance liquid chromatography-mass spectrometry (HPLC-MS) has gained increasingly in importance for monitoring organic trace substances in water resources targeted for the production of drinking water. In this article a new approach for evaluating the data from non-target HPLC-MS screening in water is introduced and its advantages are demonstrated using the supply of drinking water as an example. The crucial difference between this and other approaches is the comparison of samples based on compounds (features) determined by their full scan data. In so doing, we take advantage of the temporal, spatial, or process-based relationships among the samples by applying the set operators, UNION, INTERSECT, and COMPLEMENT to the features of each sample. This approach regards all compounds, detectable by the used analytical method. That is the fundamental meaning of non-target screening, which includes all analytical information from the applied technique for further data evaluation. In the given example, in just one step, all detected features (1729) of a landfill leachate sample could be examined for their relevant influences on water purification respectively drinking water. This study shows that 1721 out of 1729 features were not relevant for the water purification. Only eight features could be determined in the untreated water and three of them were found in the final drinking water after ozonation. In so doing, it was possible to identify 1-adamantylamine as contamination of the landfill in the drinking water at a concentration in the range of 20 ng L(-1). To support the identification of relevant compounds and their transformation products, the DAIOS database (Database-Assisted Identification of Organic Substances) was used. This database concept includes some functions such as product ion search to increase the efficiency of the database query after the screening. To identify related transformation products the database function "transformation tree" was used. Copyright © 2011 Elsevier Ltd. All rights reserved.
Agüera, Ana; Martínez Bueno, María Jesús; Fernández-Alba, Amadeo R
2013-06-01
Since the so-called emerging contaminants were established as a new group of pollutants of environmental concern, a great effort has been devoted to the knowledge of their distribution, fate and effects in the environment. After more than 20 years of work, a significant improvement in knowledge about these contaminants has been achieved, but there is still a large gap of information on the growing number of new potential contaminants that are appearing and especially of their unpredictable transformation products. Although the environmental problem arising from emerging contaminants must be addressed from an interdisciplinary point of view, it is obvious that analytical chemistry plays an important role as the first step of the study, as it allows establishing the presence of chemicals in the environment, estimate their concentration levels, identify sources and determine their degradation pathways. These tasks involve serious difficulties requiring different analytical solutions adjusted to purpose. Thus, the complexity of the matrices requires highly selective analytical methods; the large number and variety of compounds potentially present in the samples demands the application of wide scope methods; the low concentrations at which these contaminants are present in the samples require a high detection sensitivity, and high demands on the confirmation and high structural information are needed for the characterisation of unknowns. New developments on analytical instrumentation have been applied to solve these difficulties. Furthermore and not less important has been the development of new specific software packages intended for data acquisition and, in particular, for post-run analysis. Thus, the use of sophisticated software tools has allowed successful screening analysis, determining several hundreds of analytes, and assisted in the structural elucidation of unknown compounds in a timely manner.
Materials Compatibility Testing in Concentrated Hydrogen Peroxide
NASA Technical Reports Server (NTRS)
Boxwell, R.; Bromley, G.; Mason, D.; Crockett, D.; Martinez, L.; McNeal, C.; Lyles, G. (Technical Monitor)
2000-01-01
Materials test methods from the 1960's have been used as a starting point in evaluating materials for today's space launch vehicles. These established test methods have been modified to incorporate today's analytical laboratory equipment. The Orbital test objective was to test a wide range of materials to incorporate the revolution in polymer and composite materials that has occurred since the 1960's. Testing is accomplished in 3 stages from rough screening to detailed analytical tests. Several interesting test observations have been made during this testing and are included in the paper. A summary of the set-up, test and evaluation of long-term storage sub-scale tanks is also included. This sub-scale tank test lasted for a 7-month duration prior to being stopped due to a polar boss material breakdown. Chemical evaluations of the hydrogen peroxide and residue left on the polar boss surface identify the material breakdown quite clearly. The paper concludes with recommendations for future testing and a specific effort underway within the industry to standardize the test methods used in evaluating materials.
Cacho, J I; Nicolás, J; Viñas, P; Campillo, N; Hernández-Córdoba, M
2016-12-02
A solventless analytical method is proposed for analyzing the compounds responsible for cork taint in cork stoppers. Direct sample introduction (DSI) is evaluated as a sample introduction system for the gas chromatography-mass spectrometry (GC-MS) determination of four haloanisoles (HAs) in cork samples. Several parameters affecting the DSI step, including desorption temperature and time, gas flow rate and other focusing parameters, were optimized using univariate and multivariate approaches. The proposed method shows high sensitivity and minimises sample handling, with detection limits of 1.6-2.6ngg -1 , depending on the compound. The suitability of the optimized procedure as a screening method was evaluated by obtaining decision limits (CCα) and detection capabilities (CCβ) for each analyte, which were found to be in 6.9-11.8 and 8.7-14.8ngg -1 , respectively, depending on the compound. Twenty-four cork samples were analysed, and 2,4,6-trichloroanisole was found in four of them at levels between 12.6 and 53ngg -1 . Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lattin, F.G.; Paul, D.G.; Jakubowski, E.M.
1994-12-31
The Real Time Analytical Platform (RTAP) is designed to provide mobile, real-time monitoring support to ensure protection of worker safety in areas where military unique compounds are used and stored, and at disposal sites. Quantitative analysis of low-level vapor concentrations in air is accomplished through sorbent-based collection with subsequent thermal desorption into a gas chromatograph (GC) equipped with a variety of detectors. The monitoring system is characterized by its sensitivity (ability to measure at low concentrations), selectivity (ability to filter out interferences), dynamic range and linearity, real time mode (versus methods requiring extensive sample preparation procedures), and ability to interfacemore » with complimentary GC detectors. This presentation describes an RTAP analytical method for analyzing lewisite, an arsenical compound, that consists of a GC screening technique with an Electron Capture Detector (ECD), and a confirmation technique using an Atomic Emission Detector (AED). Included in the presentation is a description of quality assurance objectives in the monitoring system, and an assessment of method accuracy, precision and detection levels.« less
Wielogorska, Ewa; Chevallier, Olivier; Black, Connor; Galvin-King, Pamela; Delêtre, Marc; Kelleher, Colin T; Haughey, Simon A; Elliott, Christopher T
2018-01-15
Due to increasing number of food fraud incidents, there is an inherent need for the development and implementation of analytical platforms enabling detection and quantitation of adulteration. In this study a set of unique biomarkers of commonly found oregano adulterants became the targets in the development of a LC-MS/MS method which underwent a rigorous in-house validation. The method presented very high selectivity and specificity, excellent linearity (R 2 >0.988) low decision limits and detection capabilities (<2%), acceptable accuracy (intra-assay 92-113%, inter-assay 69-138%) and precision (CV<20%). The method was compared with an established FTIR screening assay and revealed a good correlation of quali- and quantitative results (R 2 >0.81). An assessment of 54 suspected adulterated oregano samples revealed that almost 90% of them contained at least one bulking agent, with a median level of adulteration of 50%. Such innovative methodologies need to be established as routine testing procedures to detect and ultimately deter food fraud. Copyright © 2017 Elsevier Ltd. All rights reserved.
Vasa previa screening strategies: a decision and cost-effectiveness analysis.
Sinkey, R G; Odibo, A O
2018-05-22
The aim of this study is to perform a decision and cost-effectiveness analysis comparing four screening strategies for the antenatal diagnosis of vasa previa among singleton pregnancies. A decision-analytic model was constructed comparing vasa previa screening strategies. Published probabilities and costs were applied to four transvaginal screening scenarios which occurred at the time of mid-trimester ultrasound: no screening, ultrasound-indicated screening, screening pregnancies conceived by in vitro fertilization (IVF), and universal screening. Ultrasound-indicated screening was defined as performing a transvaginal ultrasound at the time of routine anatomy ultrasound in response to one of the following sonographic findings associated with an increased risk of vasa previa: low-lying placenta, marginal or velamentous cord insertion, or bilobed or succenturiate lobed placenta. The primary outcome was cost per quality adjusted life years (QALY) in U.S. dollars. The analysis was from a healthcare system perspective with a willingness to pay (WTP) threshold of $100,000 per QALY selected. One-way and multivariate sensitivity analyses (Monte-Carlo simulation) were performed. This decision-analytic model demonstrated that screening pregnancies conceived by IVF was the most cost-effective strategy with an incremental cost effectiveness ratio (ICER) of $29,186.50 / QALY. Ultrasound-indicated screening was the second most cost-effective with an ICER of $56,096.77 / QALY. These data were robust to all one-way and multivariate sensitivity analyses performed. Within our baseline assumptions, transvaginal ultrasound screening for vasa previa appears to be most cost-effective when performed among IVF pregnancies. However, both IVF and ultrasound-indicated screening strategies fall within contemporary willingness-to-pay thresholds, suggesting that both strategies may be appropriate to apply in clinical practice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
van de Water, A T M; Benjamin, D R
2016-02-01
Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.
Thielmann, Yvonne; Koepke, Juergen; Michel, Hartmut
2012-06-01
Structure determination of membrane proteins and membrane protein complexes is still a very challenging field. To facilitate the work on membrane proteins the Core Centre follows a strategy that comprises four labs of protein analytics and crystal handling, covering mass spectrometry, calorimetry, crystallization and X-ray diffraction. This general workflow is presented and a capacity of 20% of the operating time of all systems is provided to the European structural biology community within the ESFRI Instruct program. A description of the crystallization service offered at the Core Centre is given with detailed information on screening strategy, screens used and changes to adapt high throughput for membrane proteins. Our aim is to constantly develop the Core Centre towards the usage of more efficient methods. This strategy might also include the ability to automate all steps from crystallization trials to crystal screening; here we look ahead how this aim might be realized at the Core Centre.
Mess, Aylin; Enthaler, Bernd; Fischer, Markus; Rapp, Claudius; Pruns, Julia K; Vietzke, Jens-Peter
2013-01-15
Identification of endogenous skin surface compounds is an intriguing challenge in comparative skin investigations. Notably, this short communication is focused on the analysis of small molecules, e.g. natural moisturizing factor (NMF) components and lipids, using a novel sampling method with DIP-it samplers for non-invasive examination of the human skin surface. As a result, extraction of analytes directly from the skin surface by use of various solvents can be replaced with the mentioned procedure. Screening of measureable compounds is achieved by direct analysis in real time mass spectrometry (DART-MS) without further sample preparation. Results are supplemented by dissolving analytes from the DIP-it samplers by use of different solvents, and subsequent matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) measurements. An interesting comparison of the mentioned MS techniques for determination of skin surface compounds in the mass range of 50-1000 Da is presented. Copyright © 2012 Elsevier B.V. All rights reserved.
Fire control method and analytical model for large liquid hydrocarbon pool fires
NASA Technical Reports Server (NTRS)
Fenton, D. L.
1986-01-01
The dominate parameter governing the behavior of a liquid hydrocarbon (JP-5) pool fire is wind speed. The most effective method of controlling wind speed in the vicinity of a large circular (10 m dia.) pool fire is a set of concentric screens located outside the perimeter. Because detailed behavior of the pool fire structure within one pool fire diameter is unknown, an analytical model supported by careful experiments is under development. As a first step toward this development, a regional pool fire model was constructed for the no-wind condition consisting of three zones -- liquid fuel, combustion, and plume -- where the predicted variables are mass burning rate and characteristic temperatures of the combustion and plume zones. This zone pool fire model can be modified to incorporate plume bending by wind, radiation absorption by soot particles, and a different ambient air flow entrainment rate. Results from the zone model are given for a pool diameter of 1.3 m and are found to reproduce values in the literature.
Ueland, Maiken; Blanes, Lucas; Taudte, Regina V; Stuart, Barbara H; Cole, Nerida; Willis, Peter; Roux, Claude; Doble, Philip
2016-03-04
A novel microfluidic paper-based analytical device (μPAD) was designed to filter, extract, and pre-concentrate explosives from soil for direct analysis by a lab on a chip (LOC) device. The explosives were extracted via immersion of wax-printed μPADs directly into methanol soil suspensions for 10min, whereby dissolved explosives travelled upwards into the μPAD circular sampling reservoir. A chad was punched from the sampling reservoir and inserted into a LOC well containing the separation buffer for direct analysis, avoiding any further extraction step. Eight target explosives were separated and identified by fluorescence quenching. The minimum detectable amounts for all eight explosives were between 1.4 and 5.6ng with recoveries ranging from 53-82% from the paper chad, and 12-40% from soil. This method provides a robust and simple extraction method for rapid identification of explosives in complex soil samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Web-based newborn screening system for metabolic diseases: machine learning versus clinicians.
Chen, Wei-Hsin; Hsieh, Sheau-Ling; Hsu, Kai-Ping; Chen, Han-Ping; Su, Xing-Yu; Tseng, Yi-Ju; Chien, Yin-Hsiu; Hwu, Wuh-Liang; Lai, Feipei
2013-05-23
A hospital information system (HIS) that integrates screening data and interpretation of the data is routinely requested by hospitals and parents. However, the accuracy of disease classification may be low because of the disease characteristics and the analytes used for classification. The objective of this study is to describe a system that enhanced the neonatal screening system of the Newborn Screening Center at the National Taiwan University Hospital. The system was designed and deployed according to a service-oriented architecture (SOA) framework under the Web services .NET environment. The system consists of sample collection, testing, diagnosis, evaluation, treatment, and follow-up services among collaborating hospitals. To improve the accuracy of newborn screening, machine learning and optimal feature selection mechanisms were investigated for screening newborns for inborn errors of metabolism. The framework of the Newborn Screening Hospital Information System (NSHIS) used the embedded Health Level Seven (HL7) standards for data exchanges among heterogeneous platforms integrated by Web services in the C# language. In this study, machine learning classification was used to predict phenylketonuria (PKU), hypermethioninemia, and 3-methylcrotonyl-CoA-carboxylase (3-MCC) deficiency. The classification methods used 347,312 newborn dried blood samples collected at the Center between 2006 and 2011. Of these, 220 newborns had values over the diagnostic cutoffs (positive cases) and 1557 had values that were over the screening cutoffs but did not meet the diagnostic cutoffs (suspected cases). The original 35 analytes and the manifested features were ranked based on F score, then combinations of the top 20 ranked features were selected as input features to support vector machine (SVM) classifiers to obtain optimal feature sets. These feature sets were tested using 5-fold cross-validation and optimal models were generated. The datasets collected in year 2011 were used as predicting cases. The feature selection strategies were implemented and the optimal markers for PKU, hypermethioninemia, and 3-MCC deficiency were obtained. The results of the machine learning approach were compared with the cutoff scheme. The number of the false positive cases were reduced from 21 to 2 for PKU, from 30 to 10 for hypermethioninemia, and 209 to 46 for 3-MCC deficiency. This SOA Web service-based newborn screening system can accelerate screening procedures effectively and efficiently. An SVM learning methodology for PKU, hypermethioninemia, and 3-MCC deficiency metabolic diseases classification, including optimal feature selection strategies, is presented. By adopting the results of this study, the number of suspected cases could be reduced dramatically.
Ayvaz, Huseyin; Rodriguez-Saona, Luis E
2015-05-01
The most common methods for acrylamide analysis in foods require the use of LC-MS/MS and GC-MS. Although these methods have great analytical performance, they need intensive sample preparation, highly specialised instrumentation, and are time consuming. In this study, portable and handheld infrared spectrometers were evaluated as rapid methods for screening acrylamide in potato chips and their performances were compared to those of benchtop infrared systems. The acrylamide content of 64 commercial potato chips (169-2453 μg/kg) was determined by LC-MS/MS. Spectral data were collected using mid-infrared (MIR) and near-infrared (NIR) spectrometers. Partial least squares regression (PLSR) calibration models were developed to predict acrylamide levels. Overall, good linear correlation was found between the predicted acrylamide levels and actual measured acrylamide concentrations by LC-MS/MS (rPred > 0.90 and SEP < 100 μg/kg). Our results indicate that portable and handheld spectrometers can be used as simple and rapid alternatives for acrylamide analysis in potato chips. Copyright © 2014 Elsevier Ltd. All rights reserved.
Thermodynamics of Thomas-Fermi screened Coulomb systems
NASA Technical Reports Server (NTRS)
Firey, B.; Ashcroft, N. W.
1977-01-01
We obtain in closed analytic form, estimates for the thermodynamic properties of classical fluids with pair potentials of Yukawa type, with special reference to dense fully ionized plasmas with Thomas-Fermi or Debye-Hueckel screening. We further generalize the hard-sphere perturbative approach used for similarly screened two-component mixtures, and demonstrate phase separation in this simple model of a liquid mixture of metallic helium and hydrogen.
Zhuo, Rongjie; Liu, Hao; Liu, Ningning; Wang, Yi
2016-11-11
Identification of active compounds from natural products is a critical and challenging task in drug discovery pipelines. Besides commonly used bio-guided screening approaches, affinity selection strategy coupled with liquid chromatography or mass spectrometry, known as ligand fishing, has been gaining increasing interest from researchers. In this review, we summarized this emerging strategy and categorized those methods as off-line or on-line mode according to their features. The separation principles of ligand fishing were introduced based on distinct analytical techniques, including biochromatography, capillary electrophoresis, ultrafiltration, equilibrium dialysis, microdialysis, and magnetic beads. The applications of ligand fishing approaches in the discovery of lead compounds were reviewed. Most of ligand fishing methods display specificity, high efficiency, and require less sample pretreatment, which makes them especially suitable for screening active compounds from complex mixtures of natural products. We also summarized the applications of ligand fishing in the modernization of Traditional Chinese Medicine (TCM), and propose some perspectives of this remarkable technique.
de Lima Stebbins, Daniela; Docs, Jon; Lowe, Paula; Cohen, Jason; Lei, Hongxia
2016-05-18
The hormones listed in the screening survey list 2 of the Unregulated Contaminant Monitoring Rule 3 (estrone, 17-β-estradiol, 17-α-ethynylestradiol, 16-α-hydroxyestradiol (estriol), equilin, testosterone and 4-androstene-3,17-dione) were analyzed by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Two analytical methods were compared: EPA method 539 and the isotope dilution method. EPA method 539 was successfully utilized in river and drinking water matrices with fortified recoveries of 98.9 to 108.5%. Samples from the Hillsborough River reflected levels below the method detection limit (MDL) for the majority of the analytes, except estrone (E1), which was detected at very low concentrations (<0.5 to 1 ng L(-1)) in the majority of samples. No hormones were detected in drinking water samples. The isotope dilution method was used to analyze reclaimed and aquifer storage and recovery (ASR) water samples as a result of strong matrix/solid phase extraction (SPE) losses observed in these more complex matrices. Most of the compounds were not detected or found at relatively low concentrations in the ASR samples. Attenuation of 50 to 99.1% was observed as a result of the ASR recharge/recovery cycles for most of the hormones, except for estriol (E3). Relatively stable concentrations of E3 were found, with only 10% attenuation at one of the sites and no measureable attenuation at another location. These results have substantiated that while EPA method 539 works well for most environmental samples, the isotope dilution method is more robust when dealing with complex matrices such as reclaimed and ASR samples.
Shin, Jeong-Sook; Peng, Lei; Kang, Kyungsu; Choi, Yongsoo
2016-09-09
Direct analysis of prostaglandin-E2 (PGE2) and -D2 (PGD2) produced from a RAW264.7 cell-based reaction was performed by liquid chromatography high-resolution mass spectrometry (LC-HRMS), which was online coupled with turbulent flow chromatography (TFC). The capability of this method to accurately measure PG levels in cell reaction medium containing cytokines or proteins as a reaction byproduct was cross-validated by two conventional methods. Two methods, including an LC-HRMS method after liquid-liquid extraction (LLE) of the sample and a commercial PGE2 enzyme-linked immunosorbent assay (ELISA), showed PGE2 and/or PGD2 levels almost similar to those obtained by TFC LC-HRMS over the reaction time after LPS stimulation. After the cross-validation, significant analytical throughputs, allowing simultaneous screening and potency evaluation of 80 natural products including 60 phytochemicals and 20 natural product extracts for the inhibition of the PGD2 produced in the cell-based inflammatory reaction, were achieved using the TFC LC-HRMS method developed. Among the 60 phytochemicals screened, licochalcone A and formononetin inhibited PGD2 production the most with IC50 values of 126 and 151nM, respectively. For a reference activity, indomethacin and diclofenac were used, measuring IC50 values of 0.64 and 0.21nM, respectively. This method also found a butanol extract of Akebia quinata Decne (AQ) stem as a promising natural product for PGD2 inhibition. Direct and accurate analysis of PGs in the inflammatory cell reaction using the TFC LC-HRMS method developed enables the high-throughput screening and potency evaluation of as many as 320 samples in less than 48h without changing a TFC column. Copyright © 2016 Elsevier B.V. All rights reserved.
Salivary biomarker development using genomic, proteomic and metabolomic approaches
2012-01-01
The use of saliva as a diagnostic sample provides a non-invasive, cost-efficient method of sample collection for disease screening without the need for highly trained professionals. Saliva collection is far more practical and safe compared with invasive methods of sample collection, because of the infection risk from contaminated needles during, for example, blood sampling. Furthermore, the use of saliva could increase the availability of accurate diagnostics for remote and impoverished regions. However, the development of salivary diagnostics has required technical innovation to allow stabilization and detection of analytes in the complex molecular mixture that is saliva. The recent development of cost-effective room temperature analyte stabilization methods, nucleic acid pre-amplification techniques and direct saliva transcriptomic analysis have allowed accurate detection and quantification of transcripts found in saliva. Novel protein stabilization methods have also facilitated improved proteomic analyses. Although candidate biomarkers have been discovered using epigenetic, transcriptomic, proteomic and metabolomic approaches, transcriptomic analyses have so far achieved the most progress in terms of sensitivity and specificity, and progress towards clinical implementation. Here, we review recent developments in salivary diagnostics that have been accomplished using genomic, transcriptomic, proteomic and metabolomic approaches. PMID:23114182
Cottenet, Geoffrey; Blancpain, Carine; Sonnard, Véronique; Chuah, Poh Fong
2013-08-01
Considering the increase of the total cultivated land area dedicated to genetically modified organisms (GMO), the consumers' perception toward GMO and the need to comply with various local GMO legislations, efficient and accurate analytical methods are needed for their detection and identification. Considered as the gold standard for GMO analysis, the real-time polymerase chain reaction (RTi-PCR) technology was optimised to produce a high-throughput GMO screening method. Based on simultaneous 24 multiplex RTi-PCR running on a ready-to-use 384-well plate, this new procedure allows the detection and identification of 47 targets on seven samples in duplicate. To comply with GMO analytical quality requirements, a negative and a positive control were analysed in parallel. In addition, an internal positive control was also included in each reaction well for the detection of potential PCR inhibition. Tested on non-GM materials, on different GM events and on proficiency test samples, the method offered high specificity and sensitivity with an absolute limit of detection between 1 and 16 copies depending on the target. Easy to use, fast and cost efficient, this multiplex approach fits the purpose of GMO testing laboratories.
Cumba, Loanda R; Smith, Jamie P; Brownson, Dale A C; Iniesta, Jesús; Metters, Jonathan P; do Carmo, Devaney R; Banks, Craig E
2015-03-07
Recent work has reported the first electroanalytical detection of pindolol using reduced graphene oxide (RGO) modified glassy carbon electrodes [S. Smarzewska and W. Ciesielski, Anal. Methods, 2014, 6, 5038] where it was reported that the use of RGO provided significant improvements in the electroanalytical signal in comparison to a bare (unmodified) glassy carbon electrode. We demonstrate, for the first time, that the electroanalytical quantification of pindolol is actually possible using bare (unmodified) screen-printed graphite electrodes (SPEs). This paper addresses the electroanalytical determination of pindolol utilising RGO modified SPEs. Surprisingly, it is found that bare (unmodified) SPEs provide superior electrochemical signatures over that of RGO modified SPEs. Consequently the electroanalytical sensing of pindolol is explored at bare unmodified SPEs where a linear range between 0.1 μM-10.0 μM is found to be possible whilst offering a limit of detection (3σ) corresponding to 0.097 μM. This provides a convenient yet analytically sensitive method for sensing pindolol. The optimised electroanalytical protocol using the unmodified SPEs, which requires no pre-treatment (electrode polishing) or electrode modification step (such as with the use of RGO), was then further applied to the determination of pindolol in urine samples. This work demonstrates that the use of RGO modified SPEs have no significant benefits when compared to the bare (unmodified) alternative and that the RGO free electrode surface can provide electro-analytically useful performances.
Kylander, M E; Weiss, D J; Jeffries, T E; Kober, B; Dolgopolova, A; Garcia-Sanchez, R; Coles, B J
2007-01-16
An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in peats and lichens is developed. This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening. Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation. No binder was used to reduce contamination. LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%, respectively, on both (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios. LA-Q-ICP-MS internal precisions on (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%. The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources. LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method. Sample heterogeneity and detector switching when measuring (208)Pb by Q-ICP-MS are identified as sources of reduced analytical performance.
Validation of an ELISA Synthetic Cannabinoids Urine Assay
Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.
2015-01-01
Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046
Hogendoom, E A; Huls, R; Dijkman, E; Hoogerbrugge, R
2001-12-14
A screening method has been developed for the determination of acidic pesticides in various types of soils. Methodology is based on the use of microwave assisted solvent extraction (MASE) for fast and efficient extraction of the analytes from the soils and coupled-column reversed-phase liquid chromatography (LC-LC) with UV detection at 228 nm for the instrumental analysis of uncleaned extracts. Four types of soils, including sand, clay and peat, with a range in organic matter content of 0.3-13% and ten acidic pesticides of different chemical families (bentazone, bromoxynil, metsulfuron-methyl, 2,4-D, MCPA, MCPP, 2,4-DP, 2,4,5-T, 2,4-DB and MCPB) were selected as matrices and analytes, respectively. The method developed included the selection of suitable MASE and LC-LC conditions. The latter consisted of the selection of a 5-microm GFF-II internal surface reversed-phase (ISRP, Pinkerton) analytical column (50 x 4.6 mm, I.D.) as the first column in the RAM-C18 configuration in combination with an optimised linear gradient elution including on-line cleanup of sample extracts and reconditioning of the columns. The method was validated with the analysis of freshly spiked samples and samples with aged residues (120 days). The four types of soils were spiked with the ten acidic pesticides at levels between 20 and 200 microg/kg. Weighted regression of the recovery data showed for most analyte-matrix combinations, including freshly spiked samples and aged residues, that the method provides overall recoveries between 60 and 90% with relative standard deviations of the intra-laboratory reproducibility's between 5 and 25%; LODs were obtained between 5 and 50 microg/kg. Evaluation of the data set with principal component analysis revealed that the parameters (i) increase of organic matter content of the soil samples and (ii) aged residues negatively effect the recovery of the analytes.
Dai, Sheng-Yun; Xu, Bing; Shi, Xin-Yuan; Xu, Xiang; Sun, Ying-Qiang; Qiao, Yan-Jiang
2017-03-01
This study is aimed to propose a continual improvement strategy based on quality by design (QbD). An ultra high performance liquid chromatography (UPLC) method was developed to accomplish the method transformation from HPLC to UPLC of Panax notogineng saponins (PNS) and achieve the continual improvement of PNS based on QbD, for example. Plackett-Burman screening design and Box-Behnken optimization design were employed to further understand the relationship between the critical method parameters (CMPs) and critical method attributes (CMAs). And then the Bayesian design space was built. The separation degree of the critical peaks (ginsenoside Rg₁ and ginsenoside Re) was over 2.0 and the analysis time was less than 17 min by a method chosen from the design space with 20% of the initial concentration of the acetonitrile, 10 min of the isocratic time and 6%•min⁻¹ of the gradient slope. At last, the optimum method was validated by accuracy profile. Based on the same analytical target profile (ATP), the comparison of HPLC and UPLC including chromatograph method, CMA identification, CMP-CMA model and system suitability test (SST) indicated that the UPLC method could shorten the analysis time, improve the critical separation and satisfy the requirement of the SST. In all, HPLC method could be replaced by UPLC for the quantity analysis of PNS. Copyright© by the Chinese Pharmaceutical Association.
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Carter, Melissa D.; Crow, Brian S.; Pantazides, Brooke G.; Watson, Caroline M.; deCastro, B. Rey; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.
2017-01-01
A high-throughput prioritization method was developed for use with a validated confirmatory method detecting organophosphorus nerve agent exposure by immunomagnetic separation-HPLC-MS/MS. A ballistic gradient was incorporated into this analytical method in order to profile unadducted butyrylcholinesterase (BChE) in clinical samples. With Zhang, et al. 1999’s Z′-factor of 0.88 ± 0.01 (SD) of control analytes and Z-factor of 0.25 ± 0.06 (SD) of serum samples, the assay is rated an “excellent assay” for the synthetic peptide controls used and a “double assay” when used to prioritize clinical samples. Hits, defined as samples containing BChE Ser-198 adducts or no BChE present, were analyzed in a confirmatory method for identification and quantitation of the BChE adduct, if present. The ability to prioritize samples by highest exposure for confirmatory analysis is of particular importance in an exposure to cholinesterase inhibitors such as organophosphorus nerve agents where a large number of clinical samples may be collected. In an initial blind screen, 67 out of 70 samples were accurately identified giving an assay accuracy of 96% and yielded no false negatives. The method is the first to provide a high-throughput prioritization assay for profiling adduction of Ser-198 BChE in clinical samples. PMID:23954929
Deng, Chunhui; Li, Ning; Zhang, Xiangmin
2004-01-01
The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD. Copyright (c) 2004 John Wiley & Sons, Ltd.
Score Reliability of Adolescent Alcohol Screening Measures: A Meta-Analytic Inquiry
ERIC Educational Resources Information Center
Shields, Alan L.; Campfield, Delia C.; Miller, Christopher S.; Howell, Ryan T.; Wallace, Kimberly; Weiss, Roger D.
2008-01-01
This study describes the reliability reporting practices in empirical studies using eight adolescent alcohol screening tools and characterizes and explores variability in internal consistency estimates across samples. Of 119 observed administrations of these instruments, 40 (34%) reported usable reliability information. The Personal Experience…
McComb, Jacqueline Q.; Rogers, Christian; Han, Fengxiang X.; Tchounwou, Paul B.
2014-01-01
With industrialization, great amounts of trace elements and heavy metals have been excavated and released on the surface of the earth and dissipated into the environments. Rapid screening technology for detecting major and trace elements as well as heavy metals in variety of environmental samples is most desired. The objectives of this study were to determine the detection limits, accuracy, repeatability and efficiency of a X-ray fluorescence spectrometer (Niton XRF analyzer) in comparison with the traditional analytical methods, inductively coupled plasma optical emission spectrometer (ICP-OES) and inductively coupled plasma optical emission spectrometer (ICP-MS) in screening of major and trace elements of environmental samples including estuary soils and sediments, contaminated soils, and biological samples. XRF is a fast and non-destructive method in measuring the total concentration of multi--elements simultaneously. Contrary to ICP-OES and ICP-MS, XRF analyzer is characterized by the limited preparation required for solid samples, non-destructive analysis, increased total speed and high throughout, the decreased production of hazardous waste and the low running costs as well as multi-elemental determination and portability in the fields. The current comparative study demonstrates that XRF is a good rapid non-destructive method for contaminated soils, sediments and biological samples containing higher concentrations of major and trace elements. Unfortunately, XRF does not have sensitive detection limits of most major and trace elements as ICP-OES or ICP-MS but it may serve as a rapid screening tool for locating hot spots of uncontaminated field soils and sediments. PMID:25861136
Spectral methods in edge-diffraction theories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, J.M.
Spectral methods for the construction of uniform asymptotic representations of the field diffracted by an aperture in a plane screen are reviewed. These are separated into contrasting approaches, roughly described as physical and geometrical. It is concluded that the geometrical methods provide a direct route to the construction of uniform representations that are formally identical to the equivalent-edge-current concept. Some interpretive and analytical difficulties that complicate the physical methods of obtaining uniform representations are analyzed. Spectral synthesis proceeds directly from the ray geometry and diffraction coefficients, without any intervening current representation, and the representation is uniform at shadow boundaries andmore » caustics of the diffracted field. The physical theory of diffraction postulates currents on the diffracting screen that give rise to the diffracted field. The difficulties encountered in evaluating the current integrals are throughly examined, and it is concluded that the additional data provided by the physical theory of diffraction (diffraction coefficients off the Keller diffraction cone) are not actually required for obtaining uniform asymptotics at the leading order. A new diffraction representation that generalizes to arbitrary plane-convex apertures a formula given by Knott and Senior [Proc. IEEE 62, 1468 (1974)] for circular apertures is deduced. 34 refs., 1 fig.« less
An enzyme-mediated protein-fragment complementation assay for substrate screening of sortase A.
Li, Ning; Yu, Zheng; Ji, Qun; Sun, Jingying; Liu, Xiao; Du, Mingjuan; Zhang, Wei
2017-04-29
Enzyme-mediated protein conjugation has gained great attention recently due to the remarkable site-selectivity and mild reaction condition affected by the nature of enzyme. Among all sorts of enzymes reported, sortase A from Staphylococcus aureus (SaSrtA) is the most popular enzyme due to its selectivity and well-demonstrated applications. Position scanning has been widely applied to understand enzyme substrate specificity, but the low throughput of chemical synthesis of peptide substrates and analytical methods (HPLC, LC-ESI-MS) have been the major hurdle to fully decode enzyme substrate profile. We have developed a simple high-throughput substrate profiling method to reveal novel substrates of SaSrtA 7M, a widely used hyperactive peptide ligase, by modified protein-fragment complementation assay (PCA). A small library targeting the LPATG motif recognized by SaSrtA 7M was generated and screened against proteins carrying N-terminal glycine. Using this method, we have confirmed all currently known substrates of the enzyme, and moreover identified some previously unknown substrates with varying activities. The method provides an easy, fast and highly-sensitive way to determine substrate profile of a peptide ligase in a high-throughput manner. Copyright © 2017 Elsevier Inc. All rights reserved.
Ozolins, D; D' Elios, M M; Ripa, T; Bailey, R; Timms, P; Spiteri, G; Haar, K; Unemo, M
2013-01-01
There is a need for updated guidance on detection, management and surveillance of sexually transmitted infections (STIs). Chlamydia, gonorrhoea and syphilisreporting needs to be mandatory in more European countries to aid collection of data. More widespread Chlamydia screening is needed in many countries as this is the only way to reduce complications. The role of Human Papillomavirus (HPV) screening in a situation where the prevalence of HPV infection has dropped significantly was also discussed in the context of the high cost of screening, the need for a relatively complex infrastructure, particularly in developing countries, and falling vaccination costs. An integrated HPV vaccination and screening policy could be the most appropriate with vaccination at 9-13 years as recommended by WHO and a single HPV screen at 35-39 years, possibly repeated thereafter every 10 years. Female and male HPV vaccination programmes could lead to near elimination of genital warts in both females and males. Surveillance of STIsshould be intensified where needed; additional or better quality data should be collected including reasons for testing, denominator data to estimate positivity rates, diagnostic methods, concurrent STIs, sexual orientation and country of acquisition; more analytical rather than descriptive epidemiology is needed.
Measurement of antinuclear antibodies and their fine specificities: time for a change in strategy?
Otten, Henny G; Brummelhuis, Walter J; Fritsch-Stork, Ruth; Leavis, Helen L; Wisse, Bram W; van Laar, Jacob M; Derksen, Ronald H W M
2017-01-01
The current strategy for antinuclear antibody (ANA) analysis involves screening for presence with a subsequent detailed analysis of their specificity. The aim of this study is to compare the clinical and financial efficacy of this strategy between different commercial tests in a large cohort of unselected patients. In all consecutive 1030 patients associations were defined between results from different ANA test systems and the pre-test probability for connective tissue disease (CTDs). Test systems were used for screening (ANA-IIF vs. CTD screen) and definition of their fine specificity (profile 3 line blot vs. CTD single analytes). Positive ANA-IIF and/or CTD screen results were found in 304 sera. Further analysis for ANA-specificity by profile 3 line blot and CTD single analytes showed 86 discrepant results of which more than a third are clinically relevant, with the CTD single analyte assay performing better than the line blot in supporting or confirming the presence of a CTD. Autoantigens present in one test but absent in the other were of minor practical use. The ANA screening and identification strategies currently employed are not cost-effective as 83% of tests were performed in order to find specific autoantibodies in patients without the fitting clinical signs or symptoms. This causes many unexpected positive results and subsequent confusion with regard to interpretation. We advocate that some autoantigens should be excluded from the line blot and CTD assays and propose the use of a cost-effective and selective ANA specificity testing purely based on clinical guidance.
Kaykhaii, Massoud; Mirbaloochzahi, Mohammad Reza
2008-12-01
The applicability of the headspace liquid phase microextraction and gas chromatography (HS-LPME/GC) for the expeditious and reliable screening of 68 well water samples for selected fuel oxygenates compounds, viz. methyl tertiary-butyl ether (MTBE), tertiary-amyl methyl ether (TAME), ethyl tertiary-butyl ether (ETBE) and n-butyl ethyl ether (n-BEE) has been evaluated. The method used 3 microl of 1:1 benzyl alcohol/1-octanol as extraction solvent, 20 min extraction time with stirring at 1,250 rpm, at 20 degrees C and salt addition of a mixture of 0.3 g ml(-1) sodium sulphate/0.1 g ml(-1) sodium chloride. The enrichment factors of this method were from 171 to 571. Limits of detection were in the range of 77-110 ng l(-1). The relative standard deviations (RSDs) at 0.05, 0.50 and 10.0 mg l(-1) of spiking levels were in the range of 1.28-6.80% with recoveries between 96.2 and 106.0%. Sixty-eight groundwater wells that were located near different gasoline reservoirs in eight largest cities of the Sistan and Balouchestan province were screened by the method. Eight contaminated wells were identified contained MTBE at levels between 0.3 and 1.7 mg l(-1). In all cases, other target analytes were at low concentrations or not detected.
Mycotoxin analysis: an update.
Krska, Rudolf; Schubert-Ullrich, Patricia; Molinelli, Alexandra; Sulyok, Michael; MacDonald, Susan; Crews, Colin
2008-02-01
Mycotoxin contamination of cereals and related products used for feed can cause intoxication, especially in farm animals. Therefore, efficient analytical tools for the qualitative and quantitative analysis of toxic fungal metabolites in feed are required. Current methods usually include an extraction step, a clean-up step to reduce or eliminate unwanted co-extracted matrix components and a separation step with suitably specific detection ability. Quantitative methods of analysis for most mycotoxins use immunoaffinity clean-up with high-performance liquid chromatography (HPLC) separation in combination with UV and/or fluorescence detection. Screening of samples contaminated with mycotoxins is frequently performed by thin layer chromatography (TLC), which yields qualitative or semi-quantitative results. Nowadays, enzyme-linked immunosorbent assays (ELISA) are often used for rapid screening. A number of promising methods, such as fluorescence polarization immunoassays, dipsticks, and even newer methods such as biosensors and non-invasive techniques based on infrared spectroscopy, have shown great potential for mycotoxin analysis. Currently, there is a strong trend towards the use of multi-mycotoxin methods for the simultaneous analysis of several of the important Fusarium mycotoxins, which is best achieved by LC-MS/MS (liquid chromatography with tandem mass spectrometry). This review focuses on recent developments in the determination of mycotoxins with a special emphasis on LC-MS/MS and emerging rapid methods.
Development of quantitative screen for 1550 chemicals with GC-MS.
Bergmann, Alan J; Points, Gary L; Scott, Richard P; Wilson, Glenn; Anderson, Kim A
2018-05-01
With hundreds of thousands of chemicals in the environment, effective monitoring requires high-throughput analytical techniques. This paper presents a quantitative screening method for 1550 chemicals based on statistical modeling of responses with identification and integration performed using deconvolution reporting software. The method was evaluated with representative environmental samples. We tested biological extracts, low-density polyethylene, and silicone passive sampling devices spiked with known concentrations of 196 representative chemicals. A multiple linear regression (R 2 = 0.80) was developed with molecular weight, logP, polar surface area, and fractional ion abundance to predict chemical responses within a factor of 2.5. Linearity beyond the calibration had R 2 > 0.97 for three orders of magnitude. Median limits of quantitation were estimated to be 201 pg/μL (1.9× standard deviation). The number of detected chemicals and the accuracy of quantitation were similar for environmental samples and standard solutions. To our knowledge, this is the most precise method for the largest number of semi-volatile organic chemicals lacking authentic standards. Accessible instrumentation and software make this method cost effective in quantifying a large, customizable list of chemicals. When paired with silicone wristband passive samplers, this quantitative screen will be very useful for epidemiology where binning of concentrations is common. Graphical abstract A multiple linear regression of chemical responses measured with GC-MS allowed quantitation of 1550 chemicals in samples such as silicone wristbands.
Li, Dapeng; Wang, Ting; Guo, Yujie; Hu, Yuanjia; Yu, Boyang; Qi, Jin
2015-12-18
Nitric oxide (NO) is an important cellular signaling molecule with extensive physiological and pathophysiological effects. NO scavengers have the potential to treat inflammation, septic shock and other related diseases, and numerous examples have been chemically synthesized or isolated from natural products. The chemical diversity of natural products, however, means that a huge effort is necessary to efficiently screen and identify bioactive compounds, especially NO scavengers. In this article, we propose an effective analytical method to screen for NO scavengers in three natural products using an online system that couples high performance liquid chromatography with tandem diode array and fluorescence detection (HPLC-DAD-FLD). Eighteen compounds from radix of Scutellaria baicalensis Georgi and green tea displayed significant NO scavenging activity whereas components of Pueraria lobata (Willd.) Ohwi had no discernable activity. The structures of the active compounds were elucidated using Agilent Accurate-Mass Q-TOF LC/MS system. Preliminary analysis of structure-activity relationships indicated that, in flavonoids, a 2,3-double bond and a 3-H atom or a 3-OH group are essential for activity. In tannins, poly-hydroxyl groups are important for NO scavenging activity. Method validation indicated that the newly developed method is both reliable and repeatable. The online method that we present provides a simple, rapid and effective way to identify and characterize NO scavengers present in natural products. Copyright © 2015 Elsevier B.V. All rights reserved.
Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro
2013-06-01
With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.
Moghaddam Tabrizi, Fatemeh; Vahdati, Sakineh; Khanahmadi, Shahriar; Barjasteh, Samira
2018-04-25
Background: In women, breast cancer accounts for 30 percent of all cancers and it is the second leading cause of mortality. Mammography is considered an effective procedure to detect early breast cancer recommended by World Health Organization. This study was aimed to evaluate breast cancer screening determinants in women referred to health centers of Urmia for mammography in 2017. Materials and Methods: In this descriptive-analytic cross-sectional study, 348 women referred to health centers of Urmia were selected using multistage sampling. Data were collected using a standard questionnaire for mammography screening determinants, with a checklist including demographic characteristics, family, social and economic factors and midwifery background. Analysis was with SPSS software version 20for descriptive and inferential statistic tests, P<0.05 being considered significant. Results: The proportion performing mammography was 12%. Significant relationships were noted with income, menopause status, a history of breast cancer in close relatives, beliefs, inaccessibility, knowledge, cues to action, emotions, self-care, and life priorities (P<0.05). There were no significant links with age at marriage, first age of delivery, number of children, duration of breastfeeding, status of residency, education, marital status, occupation, history of breastfeeding, and previous breast problems (P>0.05). Conclusions: The findings of this study showed that the status of breast cancer screening in participating women was not satisfactory. Therefore, promotion of screening methods by health policy makers in Iran is necessary and given that reliance solely on education is not sufficient, it is essential to pay attention to barriers and eliminate them. Creative Commons Attribution License
Molognoni, Luciano; Daguer, Heitor; de Sá Ploêncio, Leandro Antunes; De Dea Lindner, Juliano
2018-02-01
This paper describes an innovative fast and multipurpose method for the chemical inspection of meat and fish products by liquid chromatography-tandem mass spectrometry. Solid-liquid extraction and low temperature partitioning were applied to 17 analytes, which included large bacteriocins (3.5kDa) and small molecules (organic acids, heterocyclic compounds, polyene macrolides, alkyl esters of the p-hydroxybenzoic acid, aromatic, and aliphatic biogenic amines and polyamines). Chromatographic separation was achieved in 10min, using stationary phase of di-isopropyl-3-aminopropyl silane bound to hydroxylated silica. Method validation was in accordance to Commission Decision 657/2002/CE. Linear ranges were among 1.25-10.0mgkg -1 (natamycin and parabens), 2.50-10.0mgkg -1 (sorbate and nisin), 25.0-200mgkg -1 (biogenic amines, hexamethylenetetramine, benzoic and lactic acids), and 50.0-400mgkg -1 (citric acid). Expanded measurement uncertainty (U) was estimated by single laboratory validation combined to modeling in two calculation approaches: internal (U = 5%) and external standardization (U = 24%). Method applicability was checked on 89 real samples among raw, cooked, dry fermented and cured products, yielding acceptable recoveries. Many regulatory issues were revealed, corroborating the need for enhancement of the current analytical methods. This simple execution method dispenses the use of additional procedures of extraction and, therefore, reduces costs over time. It is suitable for routine analysis as a screening or confirmatory tool for both qualitative and quantitative results, replacing many time consuming analytical procedures. Copyright © 2017 Elsevier B.V. All rights reserved.
Rodriguez-Mozaz, Sara; de Alda, Maria J López; Barceló, Damià
2006-04-15
This work describes the application of an optical biosensor (RIver ANALyser, RIANA) to the simultaneous analysis of three relevant environmental organic pollutants, namely, the pesticides atrazine and isoproturon and the estrogen estrone, in real water samples. This biosensor is based on an indirect inhibition immunoassay which takes place at a chemically modified optical transducer chip. The spatially resolved modification of the transducer surface allows the simultaneous determination of selected target analytes by means of "total internal reflection fluorescence" (TIRF). The performance of the immunosensor method developed was evaluated against a well accepted traditional method based on solid-phase extraction followed by liquid chromatography-mass spectrometry (LC-MS). The chromatographic method was superior in terms of linearity, sensitivity and accuracy, and the biosensor method in terms of repeatability, speed, cost and automation. The application of both methods in parallel to determine the occurrence and removal of atrazine, isoproturon and estrone throughout the treatment process (sand filtration, ozonation, activated carbon filtration and chlorination) in a waterworks showed an overestimation of results in the case of the biosensor, which was partially attributed to matrix and cross-reactivity effects, in spite of the addition of ovalbumin to the sample to minimize matrix interferences. Based on the comparative performance of both techniques, the biosensor emerges as a suitable tool for fast, simple and automated screening of water pollutants without sample pretreatment. To the author's knowledge, this is the first description of the application of the biosensor RIANA in the multi-analyte configuration to the regular monitoring of pollutants in a waterworks.
Tabuchi, Takahiro; Nakayama, Tomio; Fukushima, Wakaba; Matsunaga, Ichiro; Ohfuji, Satoko; Kondo, Kyoko; Kawano, Eiji; Fukuhara, Hiroyuki; Ito, Yuri; Oshima, Akira
2015-01-01
In Japan at present, fecal occult blood testing (FOBT) is recommended for cancer screening while routine population-based prostate-specific antigen (PSA) screening is not. In future it may be necessary to increase participation in the former and decrease it in the latter. Our objectives were to explore determinants of PSA-screening participation while simultaneously taking into account factors associated with FOBT. Data were gathered from a cross-sectional study conducted with random sampling of 6191 adults in Osaka city in 2011. Of 3244 subjects (return rate 52.4%), 936 men aged 40–64 years were analyzed using log-binomial regression to explore factors related to PSA-screening participation within 1 year. Only responders for cancer screening, defined as men who participated in either FOBT or PSA-testing, were used as main study subjects. Men who were older (prevalence ratio [PR] [95% confidence interval (CI)] = 2.17 [1.43, 3.28] for 60–64 years compared with 40–49 years), had technical or junior college education (PR [95% CI] = 1.76 [1.19, 2.59] compared with men with high school or less) and followed doctors' recommendations (PR [95% CI] = 1.50 [1.00, 2.26]) were significantly more likely to have PSA-screening after multiple variable adjustment among cancer-screening responders. Attenuation in PR of hypothesized common factors was observed among cancer-screening responders compared with the usual approach (among total subjects). Using the analytical framework to account for healthy-user bias, we found three factors related to participation in PSA-screening with attenuated association of common factors. This approach may provide a more sophisticated interpretation of participation in various screenings with different levels of recommendation. PMID:25456306
Patient Perspectives on Low-Dose Computed Tomography for Lung Cancer Screening, New Mexico, 2014
Sussman, Andrew L.; Murrietta, Ambroshia M.; Getrich, Christina M.; Rhyne, Robert; Crowell, Richard E.; Taylor, Kathryn L.; Reifler, Ellen J.; Wescott, Pamela H.; Saeed, Ali I.; Hoffman, Richard M.
2016-01-01
Introduction National guidelines call for annual lung cancer screening for high-risk smokers using low-dose computed tomography (LDCT). The objective of our study was to characterize patient knowledge and attitudes about lung cancer screening, smoking cessation, and shared decision making by patient and health care provider. Methods We conducted semistructured qualitative interviews with patients with histories of heavy smoking who received care at a Federally Qualified Health Center (FQHC Clinic) and at a comprehensive cancer center-affiliated chest clinic (Chest Clinic) in Albuquerque, New Mexico. The interviews, conducted from February through September 2014, focused on perceptions about health screening, knowledge and attitudes about LDCT screening, and preferences regarding decision aids. We used a systematic iterative analytic process to identify preliminary and emergent themes and to create a coding structure. Results We reached thematic saturation after 22 interviews (10 at the FQHC Clinic, 12 at the Chest Clinic). Most patients were unaware of LDCT screening for lung cancer but were receptive to the test. Some smokers said they would consider quitting smoking if their screening result were positive. Concerns regarding screening were cost, radiation exposure, and transportation issues. To support decision making, most patients said they preferred one-on-one discussions with a provider. They also valued decision support tools (print materials, videos), but raised concerns about readability and Internet access. Conclusion Implementing lung cancer screening in sociodemographically diverse populations poses significant challenges. The value of tobacco cessation counseling cannot be overemphasized. Effective interventions for shared decision making to undergo lung cancer screening will need the active engagement of health care providers and will require the use of accessible decision aids designed for people with low health literacy. PMID:27536900
Electrochemical Study and Determination of Electroactive Species with Screen-Printed Electrodes
ERIC Educational Resources Information Center
Martín-Yerga, Daniel; Costa Rama, Estefanía; Costa García, Agustín
2016-01-01
A lab appropriate to introduce voltammetric techniques and basic electrochemical parameters is described in this work. It is suitable to study theoretical concepts of electrochemistry in an applied way for analytical undergraduate courses. Two electroactive species, hexaammineruthenium and dopamine, are used as simple redox systems. Screen-printed…
Bade, Richard; Rousis, Nikolaos I; Bijlsma, Lubertus; Gracia-Lor, Emma; Castiglioni, Sara; Sancho, Juan V; Hernandez, Felix
2015-12-01
The existence of pharmaceuticals and illicit drugs (PIDs) in environmental waters has led many analytical chemists to develop screening methods for monitoring purposes. Water samples can contain a huge number of possible contaminants, commonly at low concentrations, which makes their detection and identification problematic. Liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) has proven itself effective in the screening of environmental contaminants. The present work investigates the use of the most popular HRMS instruments, quadrupole time-of-flight and linear trap quadrupole-Orbitrap, from two different laboratories. A suspect screening for PIDs was carried out on wastewater (influent and effluent) and surface water samples from Castellón, Eastern Spain, and Cremona, Northern Italy, incorporating a database of 107 PIDs (including 220 fragment ions). A comparison between the findings of both instruments and of the samples was made which highlights the advantages and drawbacks of the strategies applied in each case. In total, 28 compounds were detected and/or identified by either/both instruments with irbesartan, valsartan, benzoylecgonine and caffeine being the most commonly found compounds across all samples.
Effectiveness of a Risk Screener in Identifying Hepatitis C Virus in a Primary Care Setting
Litwin, Alain H.; Smith, Bryce D.; Koppelman, Elisa A.; McKee, M. Diane; Christiansen, Cindy L.; Gifford, Allen L.; Weinbaum, Cindy M.; Southern, William N.
2012-01-01
Objectives. We evaluated an intervention designed to identify patients at risk for hepatitis C virus (HCV) through a risk screener used by primary care providers. Methods. A clinical reminder sticker prompted physicians at 3 urban clinics to screen patients for 12 risk factors and order HCV testing if any risks were present. Risk factor data were collected from the sticker; demographic and testing data were extracted from electronic medical records. We used the t test, χ2 test, and rank-sum test to compare patients who had and had not been screened and developed an analytic model to identify the incremental value of each element of the screener. Results. Among screened patients, 27.8% (n = 902) were identified as having at least 1 risk factor. Of screened patients with risk factors, 55.4% (n = 500) were tested for HCV. Our analysis showed that 7 elements (injection drug use, intranasal drug use, elevated alanine aminotransferase, transfusions before 1992, ≥ 20 lifetime sex partners, maternal HCV, existing liver disease) accounted for all HCV infections identified. Conclusions. A brief risk screener with a paper-based clinical reminder was effective in increasing HCV testing in a primary care setting. PMID:22994166
Zhang, Guozhu; Xie, Changsheng; Zhang, Shunping; Zhao, Jianwei; Lei, Tao; Zeng, Dawen
2014-09-08
A combinatorial high-throughput temperature-programmed method to obtain the optimal operating temperature (OOT) of gas sensor materials is demonstrated here for the first time. A material library consisting of SnO2, ZnO, WO3, and In2O3 sensor films was fabricated by screen printing. Temperature-dependent conductivity curves were obtained by scanning this gas sensor library from 300 to 700 K in different atmospheres (dry air, formaldehyde, carbon monoxide, nitrogen dioxide, toluene and ammonia), giving the OOT of each sensor formulation as a function of the carrier and analyte gases. A comparative study of the temperature-programmed method and a conventional method showed good agreement in measured OOT.
Mardal, Marie; Kinyua, Juliet; Ramin, Pedram; Miserez, Bram; Van Nuijs, Alexander L N; Covaci, Adrian; Meyer, Markus R
2017-01-01
Monitoring population drug use through wastewater-based epidemiology (WBE) is a useful method to quantitatively follow trends and estimate total drug consumption in communities. Concentrations of drug biomarkers might be low in wastewater due to dilution; and therefore analysis of pooled urine (PU) is useful to detect consumed drugs and identify targets of illicit drugs use. The aims of the study were (1) to screen PU and urinated soil (US) samples collected at festivals for illicit drug excretion products using hyphenated techniques; (2) to develop and validate a hydrophilic interaction liquid chromatography - mass spectrometry / mass spectrometry (HILIC-MS/MS) method of quantifying urinary targets of identified drugs in wastewater; and (3) to conduct a 24 h stability study, using PU and US to better reflect the chemical environment for targets in wastewater. Cocaine (COC) and ecstasy-like compounds were the most frequently detected illicit drugs; an analytical method was developed to quantify their excretion products. Hydroxymethoxymethamphetamine (HMMA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), HMMA sulfate (HMMA-S), benzoylecgonine (BE), and cocaethylene (CE) had 85-102% of initial concentration after 8 h of incubation, whereas COC and ecgonine methyl ester (EME) had 74 and 67% after 8 h, respectively. HMMA showed a net increase during 24 h of incubation (107% ± 27, n = 8), possibly due to the cleavage of HMMA conjugates, and biotransformation of MDMA. The results suggest HMMA as analytical target for MDMA consumption in WBE, due to its stability in wastewater and its excretion as the main phase I metabolite of MDMA. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Wang, Peilong; Wang, Xiao; Zhang, Wei; Su, Xiaoou
2014-02-01
A novel and efficient determination method for multi-class compounds including β-agonists, sedatives, nitro-imidazoles and aflatoxins in porcine formula feed based on a fast "one-pot" extraction/multifunction impurity adsorption (MFIA) clean-up procedure has been developed. 23 target analytes belonging to four different class compounds could be determined simultaneously in a single run. Conditions for "one-pot" extraction were studied in detail. Under the optimized conditions, the multi-class compounds in porcine formula feed samples were extracted and purified with methanol contained ammonia and absorbents by one step. The compounds in extracts were purified by using multi types of absorbent based on MFIA in one pot. The multi-walled carbon nanotubes were employed to improved clean-up efficiency. Shield BEH C18 column was used to separate 23 target analytes, followed by tandem mass spectrometry (MS/MS) detection using an electro-spray ionization source in positive mode. Recovery studies were done at three fortification levels. Overall average recoveries of target compounds in porcine formula feed at each levels were >51.6% based on matrix fortified calibration with coefficients of variation from 2.7% to 13.2% (n=6). The limit of determination (LOD) of these compounds in porcine formula feed sample matrix was <5.0 μg/kg. This method was successfully applied in screening and confirmation of target drugs in >30 porcine formula feed samples. It was demonstrated that the integration of the MFIA protocol with the MS/MS instrument could serve as a valuable strategy for rapid screening and reliable confirmatory analysis of multi-class compounds in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini
2016-11-15
For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Patel, Dhavalkumar Narendrabhai; Li, Lin; Kee, Chee-Leong; Ge, Xiaowei; Low, Min-Yong; Koh, Hwee-Ling
2014-01-01
The popularity of phosphodiesterase type 5 (PDE-5) enzyme inhibitors for the treatment of erectile dysfunction has led to the increase in prevalence of illicit sexual performance enhancement products. PDE-5 inhibitors, namely sildenafil, tadalafil and vardenafil, and their unapproved designer analogues are being increasingly used as adulterants in the herbal products and health supplements marketed for sexual performance enhancement. To date, more than 50 unapproved analogues of prescription PDE-5 inhibitors were found as adulterants in the literature. To avoid detection of such adulteration by standard screening protocols, the perpetrators of such illegal products are investing time and resources to synthesize exotic analogues and devise novel means for adulteration. A comprehensive review of conventional and advance analytical techniques to detect and characterize the adulterants is presented. The rapid identification and structural elucidation of unknown analogues as adulterants is greatly enhanced by the wide myriad of analytical techniques employed, including high performance liquid chromatography (HPLC), gas chromatography-mass spectrometry (GC-MS), liquid chromatography mass-spectrometry (LC-MS), nuclear magnetic resonance (NMR) spectroscopy, vibrational spectroscopy, liquid chromatography-Fourier transform ion cyclotron resonance-mass spectrometry (LC-FT-ICR-MS), liquid chromatograph-hybrid triple quadrupole linear ion trap mass spectrometer with information dependent acquisition, ultra high performance liquid chromatography-time of flight-mass spectrometry (UHPLC-TOF-MS), ion mobility spectroscopy (IMS) and immunoassay methods. The many challenges in detecting and characterizing such adulterants, and the need for concerted effort to curb adulteration in order to safe guard public safety and interest are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Chunyan; Zhu, Hongbin; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-02-01
The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC-MS/MS method in 17-19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC-MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.
López, S Herrera; Ulaszewska, M M; Hernando, M D; Martínez Bueno, M J; Gómez, M J; Fernández-Alba, A R
2014-11-01
This study describes a comprehensive strategy for detecting and elucidating the chemical structures of expected and unexpected transformation products (TPs) from chemicals found in river water and effluent wastewater samples, using liquid chromatography coupled to electrospray ionization quadrupole-time-of-flight mass spectrometer (LC-ESI-QTOF-MS), with post-acquisition data processing and an automated search using an in-house database. The efficacy of the mass defect filtering (MDF) approach to screen metabolites from common biotransformation pathways was tested, and it was shown to be sufficiently sensitive and applicable for detecting metabolites in environmental samples. Four omeprazole metabolites and two venlafaxine metabolites were identified in river water samples. This paper reports the analytical results obtained during 2 years of monitoring, carried out at eight sampling points along the Henares River (Spain). Multiresidue monitoring, for targeted analysis, includes a group of 122 chemicals, amongst which are pharmaceuticals, personal care products, pesticides and PAHs. For this purpose, two analytical methods were used based on direct injection with a LC-ESI-QTOF-MS system and stir bar sorptive extraction (SBSE) with bi-dimensional gas chromatography coupled with a time-of-flight spectrometer (GCxGC-EI-TOF-MS).
Total reflection X-ray fluorescence as a tool for food screening
NASA Astrophysics Data System (ADS)
Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.
2015-11-01
This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.
Advances on a Decision Analytic Approach to Exposure-Based Chemical Prioritization.
Wood, Matthew D; Plourde, Kenton; Larkin, Sabrina; Egeghy, Peter P; Williams, Antony J; Zemba, Valerie; Linkov, Igor; Vallero, Daniel A
2018-05-11
The volume and variety of manufactured chemicals is increasing, although little is known about the risks associated with the frequency and extent of human exposure to most chemicals. The EPA and the recent signing of the Lautenberg Act have both signaled the need for high-throughput methods to characterize and screen chemicals based on exposure potential, such that more comprehensive toxicity research can be informed. Prior work of Mitchell et al. using multicriteria decision analysis tools to prioritize chemicals for further research is enhanced here, resulting in a high-level chemical prioritization tool for risk-based screening. Reliable exposure information is a key gap in currently available engineering analytics to support predictive environmental and health risk assessments. An elicitation with 32 experts informed relative prioritization of risks from chemical properties and human use factors, and the values for each chemical associated with each metric were approximated with data from EPA's CP_CAT database. Three different versions of the model were evaluated using distinct weight profiles, resulting in three different ranked chemical prioritizations with only a small degree of variation across weight profiles. Future work will aim to include greater input from human factors experts and better define qualitative metrics. © 2018 Society for Risk Analysis.
Kaserzon, Sarit L; Heffernan, Amy L; Thompson, Kristie; Mueller, Jochen F; Gomez Ramos, Maria Jose
2017-09-01
Access to clean, safe drinking water poses a serious challenge to regulators, and requires analytical strategies capable of rapid screening and identification of potentially hazardous chemicals, specifically in situations when threats to water quality or security require rapid investigations and potential response. This study describes a fast and efficient chemical hazard screening strategy for characterising trace levels of polar organic contaminants in water matrices, based on liquid chromatography high resolution mass spectrometry with post-acquisition 'case-control' data processing. This method allowed for a rapid response time of less than 24 h for the screening of target, suspect and non-target unknown chemicals via direct injection analysis, and a second, more sensitive analysis option requiring sample pre-concentration. The method was validated by fortifying samples with a range of pesticides, pharmaceuticals and personal care products (n = 46); with >90% of target compounds positively screened in samples at 1 ng mL -1 , and 46% at 0.1 ng mL -1 when analysed via direct injection. To simulate a contamination event samples were fortified with compounds not present in the commercial library (designated 'non-target compounds'; fipronil and fenitrothion), tentatively identified at 0.2 and 1 ng mL -1 , respectively; and a compound not included in any known commercial library or public database (designated 'unknown' compounds; 8Cl - perfluorooctanesulfonic acid), at 0.8 ng mL -1 . The method was applied to two 'real-case' scenarios: (1) the assessment of drinking water safety during a high-profile event in Brisbane, Australia; and (2) to screen treated, re-circulated drinking water and pre-treated (raw) water. The validated workflow was effective for rapid prioritisation and screening of suspect and non-target potential hazards at trace levels, and could be applied to a wide range of matrices and investigations where comparison of organic contaminants between an affected and control site and or timeframe is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.
Woldegebriel, Michael; Zomer, Paul; Mol, Hans G J; Vivó-Truyols, Gabriel
2016-08-02
In this work, we introduce an automated, efficient, and elegant model to combine all pieces of evidence (e.g., expected retention times, peak shapes, isotope distributions, fragment-to-parent ratio) obtained from liquid chromatography-tandem mass spectrometry (LC-MS/MS/MS) data for screening purposes. Combining all these pieces of evidence requires a careful assessment of the uncertainties in the analytical system as well as all possible outcomes. To-date, the majority of the existing algorithms are highly dependent on user input parameters. Additionally, the screening process is tackled as a deterministic problem. In this work we present a Bayesian framework to deal with the combination of all these pieces of evidence. Contrary to conventional algorithms, the information is treated in a probabilistic way, and a final probability assessment of the presence/absence of a compound feature is computed. Additionally, all the necessary parameters except the chromatographic band broadening for the method are learned from the data in training and learning phase of the algorithm, avoiding the introduction of a large number of user-defined parameters. The proposed method was validated with a large data set and has shown improved sensitivity and specificity in comparison to a threshold-based commercial software package.
Bouden, Sarra; Chaussé, Annie; Dorbes, Stephane; El Tall, Omar; Bellakhal, Nizar; Dachraoui, Mohamed; Vautrin-Ul, Christine
2013-03-15
This paper describes the use of 4-carboxyphenyl-grafted screen-printed carbon electrodes (4-CP-SPEs) for trace lead analysis. These novel and simple use of electrodes were easily prepared by the electrochemical reduction of the corresponding diazonium salt. Pb detection was then performed by a three-steps method in order to avoid oxygen interference: (i) immersion of the grafted screen-printed electrode (SPE) in the sample and adsorption of Pb(II), (ii) reduction of adsorbed Pb(II) by chronoamperometry (CA), and (iii) oxidation of Pb by Anodic Square Wave Voltammetry (SWV). The reoxidation response was exploited for lead detection and quantification. In order to optimize the analytical responses, the influence of the adsorption medium pH and the adsorption time were investigated. Moreover, an interference study was carried out with Cu(II), Hg(II), Al(III), Mn(II), Zn(II), Cd(II) and no major interference can be expected to quantify Pb(II). The described method provided a limit of detection and a limit of quantification of 1.2 × 10(-9)M and 4.1 × 10(-9)M, respectively. These performances indicate that the 4-CP-SPE could be considered as an efficient tool for environmental analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Siebert, Uwe; Sroczynski, Gaby; Hillemanns, Peter; Engel, Jutta; Stabenow, Roland; Stegmaier, Christa; Voigt, Kerstin; Gibis, Bernhard; Hölzel, Dieter; Goldie, Sue J
2006-04-01
We sought to develop and validate a decision-analytic model for the natural history of cervical cancer for the German health care context and to apply it to cervical cancer screening. We developed a Markov model for the natural history of cervical cancer and cervical cancer screening in the German health care context. The model reflects current German practice standards for screening, diagnostic follow-up and treatment regarding cervical cancer and its precursors. Data for disease progression and cervical cancer survival were obtained from the literature and German cancer registries. Accuracy of Papanicolaou (Pap) testing was based on meta-analyses. We performed internal and external model validation using observed epidemiological data for unscreened women from different German cancer registries. The model predicts life expectancy, incidence of detected cervical cancer cases, lifetime cervical cancer risks and mortality. The model predicted a lifetime cervical cancer risk of 3.0% and a lifetime cervical cancer mortality of 1.0%, with a peak cancer incidence of 84/100,000 at age 51 years. These results were similar to observed data from German cancer registries, German literature data and results from other international models. Based on our model, annual Pap screening could prevent 98.7% of diagnosed cancer cases and 99.6% of deaths due to cervical cancer in women completely adherent to screening and compliant to treatment. Extending the screening interval from 1 year to 2, 3 or 5 years resulted in reduced screening effectiveness. This model provides a tool for evaluating the long-term effectiveness of different cervical cancer screening tests and strategies.
Rapid screening of pharmaceutical drugs using thermal desorption - SALDI mass spectrometry
NASA Astrophysics Data System (ADS)
Grechnikov, A. A.; Kubasov, A. E.; Georgieva, V. B.; Borodkov, A. S.; Nikiforov, S. M.; Simanovsky, Ya O.; Alimpiev, S. S.
2012-12-01
A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.
Dolegowska, B; Ostapowicz, A; Stanczyk-Dunaj, M; Blogowski, W
2012-08-01
5-Fluorouracil (5-FU) is one of the most commonly used chemotherapeutics in the treatment of malignancies originating from breast, prostate, ovarian, skin and gastrointestinal tissues. Around 80% of administered dose of 5-FU is catabolized by dihydropirymidine dehydrogenase (DPD). Patients, in whom a deficiency or insufficient activity of this enzyme is observed, are at great risk of development of severe, even lethal, 5-FU toxicity. According to recent studies, so far over 30 mutations of DPYD gene, which are associated with DPD deficiency/insufficiency, have already been discovered. Currently, there are several analytical methods used for measurements of DPD activity. However, in this paper we report a novel, simple, economical and more accessible spectrophotometric method for measurements of DPD activity in the peripheral blood mononuclear cells (PBMCs) that was developed and validated on analysis of 200 generally healthy volunteers aged 22-63. We present two spectrophotometric protocols in this study, and as a reference method we used already described reverse phase high-performance liquid chromatography (RP HPLC) analysis. Basing on our findings, we conclude that spectrophotometric methods may be used as a screening protocol preceding 5-FU-based chemotherapy. Nevertheless, before introduction into clinical reality, our results should be confirmed in further larger studies.
Huang, Xin; Zhai, Congcong; You, Qimin; Chen, Hongjun
2014-07-01
The requirement to monitor the presence of genetically modified organisms (GMO) in a variety of marked products has generated an increasing demand for reliable, rapid, and time and cost-effective analytical methods. Here we report an on-site method for rapid detection of cauliflower mosaic virus promoter (CaMV 35S), a common element present in most GMO, using cross-priming amplification (CPA) technology. Detection was achieved using a DNA-based contamination-proof strip biosensor. The limit of detection was 30 copies for the pBI121 plasmid containing the CaMV 35S gene. The certified reference sample of GM maize line MON810 was detectable even at the low relative mass concentration of 0.05%. The developed CPA method had high specificity for the CaMV 35S gene, as compared with other GM lines not containing this gene and non-GM products. The method was further validated using nine real-world samples, and the results were confirmed by real-time PCR analysis. Because of its simplicity, rapidity, and high sensitivity, this method of detecting the CaMV 35S gene has great commercial prospects for rapid GMO screening of high-consumption food and agriculture products.
Results of the International Energy Agency Round Robin on Fast Pyrolysis Bio-oil Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, Douglas C.; Meier, Dietrich; Oasmaa, Anja
An international round robin study of the production of fast pyrolysis bio-oil was undertaken. Fifteen institutions in six countries contributed. Three biomass samples were distributed to the laboratories for processing in fast pyrolysis reactors. Samples of the bio-oil produced were transported to a central analytical laboratory for analysis. The round robin was focused on validating the pyrolysis community understanding of production of fast pyrolysis bio-oil by providing a common feedstock for bio-oil preparation. The round robin included: •distribution of 3 feedstock samples from a common source to each participating laboratory; •preparation of fast pyrolysis bio-oil in each laboratory with themore » 3 feedstocks provided; •return of the 3 bio-oil products (minimum 500 ml) with operational description to a central analytical laboratory for bio-oil property determination. The analyses of interest were: density, viscosity, dissolved water, filterable solids, CHN, S, trace element analysis, ash, total acid number, pyrolytic lignin, and accelerated aging of bio-oil. In addition, an effort was made to compare the bio-oil components to the products of analytical pyrolysis through GC/MS analysis. The results showed that clear differences can occur in fast pyrolysis bio-oil properties by applying different reactor technologies or configurations. The comparison to analytical pyrolysis method suggested that Py-GC/MS could serve as a rapid screening method for bio-oil composition when produced in fluid-bed reactors. Furthermore, hot vapor filtration generally resulted in the most favorable bio-oil product, with respect to water, solids, viscosity, and total acid number. These results can be helpful in understanding the variation in bio-oil production methods and their effects on bio-oil product composition.« less
Khurana, Rajneet Kaur; Rao, Satish; Beg, Sarwar; Katare, O.P.; Singh, Bhupinder
2016-01-01
The present work aims at the systematic development of a simple, rapid and highly sensitive densitometry-based thin-layer chromatographic method for the quantification of mangiferin in bioanalytical samples. Initially, the quality target method profile was defined and critical analytical attributes (CAAs) earmarked, namely, retardation factor (Rf), peak height, capacity factor, theoretical plates and separation number. Face-centered cubic design was selected for optimization of volume loaded and plate dimensions as the critical method parameters selected from screening studies employing D-optimal and Plackett–Burman design studies, followed by evaluating their effect on the CAAs. The mobile phase containing a mixture of ethyl acetate : acetic acid : formic acid : water in a 7 : 1 : 1 : 1 (v/v/v/v) ratio was finally selected as the optimized solvent for apt chromatographic separation of mangiferin at 262 nm with Rf 0.68 ± 0.02 and all other parameters within the acceptance limits. Method validation studies revealed high linearity in the concentration range of 50–800 ng/band for mangiferin. The developed method showed high accuracy, precision, ruggedness, robustness, specificity, sensitivity, selectivity and recovery. In a nutshell, the bioanalytical method for analysis of mangiferin in plasma revealed the presence of well-resolved peaks and high recovery of mangiferin. PMID:26912808
Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A
2007-01-01
Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.
Gu, Liqiang; Hou, Pengyi; Zhang, Ruowen; Liu, Ziying; Bi, Kaishun; Chen, Xiaohui
2016-10-15
A Previous metabolomics study has demonstrated that tyrosine metabolism might be disrupted by treating with Semen Strychni on the cell nephrotoxicity model. To investigate the relationship between Semen Strychni alkaloids (SAs) and endogenous tyrosine, tyramine under the nephrotoxicity condition, an HILIC-ESI-MS/MS based analytical strategy was applied in this study. Based on the established Semen Strychni nephrotoxicity cell model, strychnine and brucine were identified and screened as the main SAs by an HPLC-Q Exactive hybrid quadrupole Orbitrap mass system. Then, a sensitive HILIC-ESI-MS/MS method was developed to simultaneously monitor strychnine, brucine, tyrosine and tyramine in cell lysate. The analytes were separated by a Shiseido CAPCELL CORE PC (150mm×2.1mm, 2.7μm) HILIC column in an acetonitrile/0.1% formic acid gradient system. All the calibration curves were linear with regression coefficients above 0.9924. The absolute recoveries were more than 80.5% and the matrix effects were between 91.6%-107.0%. With the developed method, analytes were successfully determined in cell lysates. Decreased levels of tyrosine and tyramine were observed only in combination with increased levels of SAs, indicating that the disturbance of tyrosine metabolism might be induced by the accumulation of SAs in kidney cell after exposure of Semen Strychni. The HILIC-ESI-MS/MS based analytical strategy is a useful tool to reveal the relationships between the toxic herb components and the endogenous metabolite profiling in the toxicity investigation of herb medicines. Copyright © 2016 Elsevier B.V. All rights reserved.
Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter
2016-01-01
Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263
NASA Astrophysics Data System (ADS)
Romero, Rodrigo; Sienra, Rosario; Richter, Pablo
A rapid analytical approach for determination of polycyclic aromatic hydrocarbons (PAHs) present in real samples of particulate matter (PM10 filters) was investigated, based on the use of water under sub critical conditions, and the subsequent determination by GC-MS (SIM). The method avoids the use of large volumes of organic solvents as dichloromethane, toluene or other unhealthy liquid organic mixtures which are normally used in time-consuming conventional sample preparation methods. By using leaching times <1 h, the method allows determination of PAHs in the range of ng/m 3 (detection limits between 0.05 and 0.2 ng/m 3 for 1458 m 3 of sampled air) with a precision expressed as RSD between 5.6% and 11.2%. The main idea behind this approach is to raise the temperature and pressure of water inside a miniaturized laboratory-made extraction unit and to decrease its dielectric constant from 80 to nearly 20. This effect allows an increase in the solubility of low polarity hydrocarbons such as PAHs. In this way, an extraction step of a few minutes can be sufficient for a quantitative extraction of airborne particles collected in high volume PM10 samplers. Parameters such as: extraction flow, static or dynamic extraction times and water volume were optimized by using a standard reference material. Technical details are given and a comparison using real samples is made between the conventional Soxhlet extraction method and the proposed approach. The proposed approach can be used as a quantitative method to characterize low molecular PAHs and simultaneously as a screening method for high molecular weight PAHs, because the recoveries are not quantitative for molecular weights over 202. In the specific case of the Santiago metropolitan area, due to the frequent occurrence of particulate matter during high pollution episodes, this approach was applied as an efficient short-time screening method for urban PAHs. Application of this screening method is recommended especially during the winter, when periods of clear detriment of the atmospheric and meteorological conditions occur in the area.
Cost-effectiveness of prenatal screening strategies for congenital heart disease.
Pinto, N M; Nelson, R; Puchalski, M; Metz, T D; Smith, K J
2014-07-01
The economic implications of strategies to improve prenatal screening for congenital heart disease (CHD) in low-risk mothers have not been explored. The aim was to perform a cost-effectiveness analysis of different screening methods. We constructed a decision analytic model of CHD prenatal screening strategies (four-chamber screen (4C), 4C + outflow, nuchal translucency (NT) or fetal echocardiography) populated with probabilities from the literature. The model included whether initial screens were interpreted by a maternal-fetal medicine (MFM) specialist and different referral strategies if they were read by a non-MFM specialist. The primary outcome was the incremental cost per defect detected. Costs were obtained from Medicare National Fee estimates. A probabilistic sensitivity analysis was undertaken on model variables commensurate with their degree of uncertainty. In base-case analysis, 4C + outflow referred to an MFM specialist was the least costly strategy per defect detected. The 4C screen and the NT screen were dominated by other strategies (i.e. were more costly and less effective). Fetal echocardiography was the most effective, but most costly. On simulation of 10 000 low-risk pregnancies, 4C + outflow screen referred to an MFM specialist remained the least costly per defect detected. For an additional $580 per defect detected, referral to cardiology after a 4C + outflow was the most cost-effective for the majority of iterations, increasing CHD detection by 13 percentage points. The addition of examination of the outflow tracts to second-trimester ultrasound increases detection of CHD in the most cost-effective manner. Strategies to improve outflow-tract imaging and to refer with the most efficiency may be the best way to improve detection at a population level. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jo, J.
This document is a report of the analytical results for samples collected from the radioactive wastes in Tank 241-U-202 at the Hanford Reservation. Core samples were collected from the solid wastes in the tank and underwent safety screening analyses including differential scanning calorimetry, thermogravimetric analysis, and total alpha analysis. Results indicate that no safety screening notification limits were exceeded.
Orlandini, S; Pasquini, B; Del Bubba, M; Pinzauti, S; Furlanetto, S
2015-02-06
Quality by design (QbD) concepts, in accordance with International Conference on Harmonisation Pharmaceutical Development guideline Q8(R2), represent an innovative strategy for the development of analytical methods. In this paper QbD principles have been comprehensively applied in the set-up of a capillary electrophoresis method aimed to quantify enantiomeric impurities. The test compound was the chiral drug substance levosulpiride (S-SUL) and the developed method was intended to be used for routine analysis of the pharmaceutical product. The target of analytical QbD approach is to establish a design space (DS) of critical process parameters (CPPs) where the critical quality attributes (CQAs) of the method have been assured to fulfil the desired requirements with a selected probability. QbD can improve the understanding of the enantioseparation process, including both the electrophoretic behavior of enantiomers and their separation, therefore enabling its control. The CQAs were represented by enantioresolution and analysis time. The scouting phase made it possible to select a separation system made by sulfated-β-cyclodextrin and a neutral cyclodextrin, operating in reverse polarity mode. The type of neutral cyclodextrin was included among other CPPs, both instrumental and related to background electrolyte composition, which were evaluated in a screening phase by an asymmetric screening matrix. Response surface methodology was carried out by a Doehlert design and allowed the contour plots to be drawn, highlighting significant interactions between some of the CPPs. DS was defined by applying Monte-Carlo simulations, and corresponded to the following intervals: sulfated-β-cyclodextrin concentration, 9-12 mM; methyl-β-cyclodextrin concentration, 29-38 mM; Britton-Robinson buffer pH, 3.24-3.50; voltage, 12-14 kV. Robustness of the method was examined by a Plackett-Burman matrix and the obtained results, together with system repeatability data, led to define a method control strategy. The method was validated and was finally applied to determine the enantiomeric purity of S-SUL in pharmaceutical dosage forms. Copyright © 2015 Elsevier B.V. All rights reserved.
Miller, Eleanor I; Wylie, Fiona M; Oliver, John S
2008-09-01
A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous identification and quantification of amphetamines, diazepam and its metabolites, cocaine and its metabolites, and opiates from hair using a single extraction method. As part of the method development, Gemini C18, Synergi Hydro RP, and Zorbax Stablebond-Phenyl LC columns were tested with three different mobile phases. Analyte recovery and limit of detection were evaluated for two different solid-phase extraction methods that used Bond Elut Certify and Clean Screen cartridges. Phosphate buffer (pH 5.0) was chosen as the optimum hair incubation medium because of the high stability of cocaine and 6-monoacetylmorphine using this method and faster sample preparation. The optimized method was fully validated. Linearity was established over the concentration range 0.2-10 ng/mg hair, and the correlation coefficients were all greater than 0.99. Total extraction recoveries were greater than 76%, detection limits were between 0.02 and 0.09 ng/mg, and the intra- and interday imprecisions were generally less than 20% in spiked hair. The intra- and interbatch imprecision of the method for a pooled authentic hair sample ranged from 1.4 to 23.4% relative standard deviation (RSD) and 8.3 to 25.4% RSD, respectively, for representative analytes from the different drug groups. The percent matrix effect ranged from 63.5 to 135.6%, with most analytes demonstrating ion suppression. Sixteen postmortem samples collected from suspected drug-related deaths were analyzed for the 17 drugs of abuse and metabolites included in the method. The method was sufficiently sensitive and specific for the analysis of drugs and metabolites in postmortem hair samples. There is scope for the inclusion of other target drugs and metabolites in the method.
Andresen, H; Aydin, B E; Mueller, A; Iwersen-Bergmann, S
2011-09-01
Abuse of gamma-hydroxybutyric acid (GHB) has been known since the early 1990's, but is not as widespread as the consumption of other illegal drugs. However, the number of severe intoxications with fatal outcomes is comparatively high; not the least of which is brought about by the consumption of the currently legal precursor substances gamma-butyrolactone (GBL) and 1,4-butanediol (1,4-BD). In regards to previous assumptions, addiction to GHB or its analogues can occur with severe symptoms of withdrawal. Moreover, GHB can be used for drug-facilitated sexual assaults. Its pharmacological effects are generated mainly by interaction with both GABA(B) and GHB receptors, as well as its influence on other transmitter systems in the human brain. Numerous analytical methods for determining GHB using chromatographic techniques were published in recent years, and an enzymatic screening method was established. However, the short window of GHB detection in blood or urine due to its rapid metabolism is a challenge. Furthermore, despite several studies addressing this problem, evaluation of analytical results can be difficult: GHB is a metabolite of GABA (gamma-aminobutyric acid); a differentiation between endogenous and exogenous concentrations has to be made. Apart from this, in samples with a longer storage interval and especially in postmortem specimens, higher levels can be measured due to GHB generation during this postmortem interval or storage time. Copyright © 2011 John Wiley & Sons, Ltd.
Samanipour, Saer; Baz-Lomba, Jose A; Alygizakis, Nikiforos A; Reid, Malcolm J; Thomaidis, Nikolaos S; Thomas, Kevin V
2017-06-09
LC-HR-QTOF-MS recently has become a commonly used approach for the analysis of complex samples. However, identification of small organic molecules in complex samples with the highest level of confidence is a challenging task. Here we report on the implementation of a two stage algorithm for LC-HR-QTOF-MS datasets. We compared the performances of the two stage algorithm, implemented via NIVA_MZ_Analyzer™, with two commonly used approaches (i.e. feature detection and XIC peak picking, implemented via UNIFI by Waters and TASQ by Bruker, respectively) for the suspect analysis of four influent wastewater samples. We first evaluated the cross platform compatibility of LC-HR-QTOF-MS datasets generated via instruments from two different manufacturers (i.e. Waters and Bruker). Our data showed that with an appropriate spectral weighting function the spectra recorded by the two tested instruments are comparable for our analytes. As a consequence, we were able to perform full spectral comparison between the data generated via the two studied instruments. Four extracts of wastewater influent were analyzed for 89 analytes, thus 356 detection cases. The analytes were divided into 158 detection cases of artificial suspect analytes (i.e. verified by target analysis) and 198 true suspects. The two stage algorithm resulted in a zero rate of false positive detection, based on the artificial suspect analytes while producing a rate of false negative detection of 0.12. For the conventional approaches, the rates of false positive detection varied between 0.06 for UNIFI and 0.15 for TASQ. The rates of false negative detection for these methods ranged between 0.07 for TASQ and 0.09 for UNIFI. The effect of background signal complexity on the two stage algorithm was evaluated through the generation of a synthetic signal. We further discuss the boundaries of applicability of the two stage algorithm. The importance of background knowledge and experience in evaluating the reliability of results during the suspect screening was evaluated. Copyright © 2017 Elsevier B.V. All rights reserved.
Cost-effectiveness of orthoptic screening in kindergarten: a decision-analytic model.
König, H H; Barry, J C; Leidl, R; Zrenner, E
2000-06-01
The purpose of this study was to analyze the cost-effectiveness of orthoptic screening for amblyopia in kindergarten. A decision-analytic model was used. In this model all kindergarten children in Germany aged 3 years were examined by an orthoptist. Children with positive screening results were referred to an ophthalmologist for diagnosis. The number of newly diagnosed cases of amblyopia, amblyogenic non-obvious strabismus and amblyogenic refractive errors was used as the measure of effectiveness. Direct costs were measured form a third-party payer perspective. Data for model parameters were obtained from the literature and from own measurements in kindergartens. A base analysis was performed using median parameter values. The influence of uncertain parameters was tested in sensitivity analyses. According to the base analysis, the cost of one orthoptic screening test was 7.87 euro. One ophthalmologic examination cost 36.40 euro. The total cost of the screening program in all kindergartens was 3.1 million euro. A total of 4,261 new cases would be detected. The cost-effectiveness ratio was 727 euro per case detected. Sensitivity analysis showed considerable influence of the prevalence rate of target conditions and of the specificity of the orthopic examination on the cost-effectiveness ratio. This analysis provides information which is useful for discussion about the implementation of orthoptic screening and for planning a field study.
Validation of an ELISA Synthetic Cannabinoids Urine Assay.
Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A
2015-10-01
Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, coadministered drugs, over-the-counter medications, or structurally similar compounds, and 19 of 73 individual synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.
Protein-targeted corona phase molecular recognition
Bisker, Gili; Dong, Juyao; Park, Hoyoung D.; Iverson, Nicole M.; Ahn, Jiyoung; Nelson, Justin T.; Landry, Markita P.; Kruss, Sebastian; Strano, Michael S.
2016-01-01
Corona phase molecular recognition (CoPhMoRe) uses a heteropolymer adsorbed onto and templated by a nanoparticle surface to recognize a specific target analyte. This method has not yet been extended to macromolecular analytes, including proteins. Herein we develop a variant of a CoPhMoRe screening procedure of single-walled carbon nanotubes (SWCNT) and use it against a panel of human blood proteins, revealing a specific corona phase that recognizes fibrinogen with high selectivity. In response to fibrinogen binding, SWCNT fluorescence decreases by >80% at saturation. Sequential binding of the three fibrinogen nodules is suggested by selective fluorescence quenching by isolated sub-domains and validated by the quenching kinetics. The fibrinogen recognition also occurs in serum environment, at the clinically relevant fibrinogen concentrations in the human blood. These results open new avenues for synthetic, non-biological antibody analogues that recognize biological macromolecules, and hold great promise for medical and clinical applications. PMID:26742890
Maternal Serologic Screening to Prevent Congenital Toxoplasmosis: A Decision-Analytic Economic Model
Stillwaggon, Eileen; Carrier, Christopher S.; Sautter, Mari; McLeod, Rima
2011-01-01
Objective To determine a cost-minimizing option for congenital toxoplasmosis in the United States. Methodology/Principal Findings A decision-analytic and cost-minimization model was constructed to compare monthly maternal serological screening, prenatal treatment, and post-natal follow-up and treatment according to the current French (Paris) protocol, versus no systematic screening or perinatal treatment. Costs are based on published estimates of lifetime societal costs of developmental disabilities and current diagnostic and treatment costs. Probabilities are based on published results and clinical practice in the United States and France. One- and two-way sensitivity analyses are used to evaluate robustness of results. Universal monthly maternal screening for congenital toxoplasmosis with follow-up and treatment, following the French protocol, is found to be cost-saving, with savings of $620 per child screened. Results are robust to changes in test costs, value of statistical life, seroprevalence in women of childbearing age, fetal loss due to amniocentesis, and to bivariate analysis of test costs and incidence of primary T. gondii infection in pregnancy. Given the parameters in this model and a maternal screening test cost of $12, screening is cost-saving for rates of congenital infection above 1 per 10,000 live births. If universal testing generates economies of scale in diagnostic tools—lowering test costs to about $2 per test—universal screening is cost-saving at rates of congenital infection well below the lowest reported rates in the United States of 1 per 10,000 live births. Conclusion/Significance Universal screening according to the French protocol is cost saving for the US population within broad parameters for costs and probabilities. PMID:21980546
Morini, Luca; Vignali, Claudia; Tricomi, Paolo; Groppi, Angelo
2015-09-01
The body of a 30-year-old woman was found in Como lake at a depth of about 120 meters in her own car after 3 years of immersion. The aim of this study was to evaluate psychoactive drugs as well as alcohol biomarkers in biological matrices. The following analyses were initially performed: GC-MS systematic toxicological analysis on biological fluids and tissues; GC-MS analysis of drugs of abuse on pubic hair; direct ethanol metabolite determination in pubic hair by LC-MS/MS. After 7 years, the samples, that had been stored at -20°C, were re-analyzed and submitted to an LC-MS/MS targeted screening method, using multiple reaction monitoring mode. These analyses detected citalopram (150-3000 ng/mL), desmethylcitalopram (50-2300 ng/mL), clotiapine (20-65 ng/mL), and ethyl glucuronide (97 pg/mg). The methods showed an acceptable reproducibility, and the concentrations of citalopram and desmethylcitalopram calculated through the two analytical techniques did not significantly differ in biological fluids. © 2015 American Academy of Forensic Sciences.
Lemasson, Elise; Bertin, Sophie; Hennig, Philippe; Boiteux, Hélène; Lesellier, Eric; West, Caroline
2015-08-21
Impurity profiling of organic products that are synthesized as possible drug candidates requires complementary analytical methods to ensure that all impurities are identified. Supercritical fluid chromatography (SFC) is a very useful tool to achieve this objective, as an adequate selection of stationary phases can provide orthogonal separations so as to maximize the chances to see all impurities. In this series of papers, we have developed a method for achiral SFC-MS profiling of drug candidates, based on a selection of 160 analytes issued from Servier Research Laboratories. In the first part of this study, focusing on mobile phase selection, a gradient elution with carbon dioxide and methanol comprising 2% water and 20mM ammonium acetate proved to be the best in terms of chromatographic performance, while also providing good MS response [1]. The objective of this second part was the selection of an orthogonal set of ultra-high performance stationary phases, that was carried out in two steps. Firstly, a reduced set of analytes (20) was used to screen 23 columns. The columns selected were all 1.7-2.5μm fully porous or 2.6-2.7μm superficially porous particles, with a variety of stationary phase chemistries. Derringer desirability functions were used to rank the columns according to retention window, column efficiency evaluated with peak width of selected analytes, and the proportion of analytes successfully eluted with good peak shapes. The columns providing the worst performances were thus eliminated and a shorter selection of columns (11) was obtained. Secondly, based on 160 tested analytes, the 11 columns were ranked again. The retention data obtained on these columns were then compared to define a reduced set of the best columns providing the greatest orthogonality, to maximize the chances to see all impurities within a limited number of runs. Two high-performance columns were thus selected: ACQUITY UPC(2) HSS C18 SB and Nucleoshell HILIC. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Minmin; Dai, Chao; Wang, Fengzhong; Kong, Zhiqiang; He, Yan; Huang, Ya Tao; Fan, Bei
2017-02-01
An effective analysis method was developed based on a chemometric tool for the simultaneous quantification of five different post-harvest pesticides (2,4-dichlorophenoxyacetic acid (2,4-D), carbendazim, thiabendazole, iprodione, and prochloraz) in fruits and vegetables. In the modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method, the factors and responses for optimization of the extraction and cleanup analyses were compared using the Plackett-Burman (P-B) screening design. Furthermore, the significant factors (toluene percentage, hydrochloric acid (HCl) percentage, and graphitized carbon black (GCB) amount) were optimized using a central composite design (CCD) combined with Derringer’s desirability function (DF). The limits of quantification (LOQs) were estimated to be 1.0 μg/kg for 2,4-D, carbendazim, thiabendazole, and prochloraz, and 1.5 μg/kg for iprodione in food matrices. The mean recoveries were in the range of 70.4-113.9% with relative standard deviations (RSDs) of less than 16.9% at three spiking levels. The measurement uncertainty of the analytical method was determined using the bottom-up approach, which yielded an average value of 7.6%. Carbendazim was most frequently found in real samples analyzed using the developed method. Consequently, the analytical method can serve as an advantageous and rapid tool for determination of five preservative pesticides in fruits and vegetables.
Li, Minmin; Dai, Chao; Wang, Fengzhong; Kong, Zhiqiang; He, Yan; Huang, Ya Tao; Fan, Bei
2017-01-01
An effective analysis method was developed based on a chemometric tool for the simultaneous quantification of five different post-harvest pesticides (2,4-dichlorophenoxyacetic acid (2,4-D), carbendazim, thiabendazole, iprodione, and prochloraz) in fruits and vegetables. In the modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method, the factors and responses for optimization of the extraction and cleanup analyses were compared using the Plackett–Burman (P–B) screening design. Furthermore, the significant factors (toluene percentage, hydrochloric acid (HCl) percentage, and graphitized carbon black (GCB) amount) were optimized using a central composite design (CCD) combined with Derringer’s desirability function (DF). The limits of quantification (LOQs) were estimated to be 1.0 μg/kg for 2,4-D, carbendazim, thiabendazole, and prochloraz, and 1.5 μg/kg for iprodione in food matrices. The mean recoveries were in the range of 70.4–113.9% with relative standard deviations (RSDs) of less than 16.9% at three spiking levels. The measurement uncertainty of the analytical method was determined using the bottom-up approach, which yielded an average value of 7.6%. Carbendazim was most frequently found in real samples analyzed using the developed method. Consequently, the analytical method can serve as an advantageous and rapid tool for determination of five preservative pesticides in fruits and vegetables. PMID:28225030
Li, Minmin; Dai, Chao; Wang, Fengzhong; Kong, Zhiqiang; He, Yan; Huang, Ya Tao; Fan, Bei
2017-02-22
An effective analysis method was developed based on a chemometric tool for the simultaneous quantification of five different post-harvest pesticides (2,4-dichlorophenoxyacetic acid (2,4-D), carbendazim, thiabendazole, iprodione, and prochloraz) in fruits and vegetables. In the modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method, the factors and responses for optimization of the extraction and cleanup analyses were compared using the Plackett-Burman (P-B) screening design. Furthermore, the significant factors (toluene percentage, hydrochloric acid (HCl) percentage, and graphitized carbon black (GCB) amount) were optimized using a central composite design (CCD) combined with Derringer's desirability function (DF). The limits of quantification (LOQs) were estimated to be 1.0 μg/kg for 2,4-D, carbendazim, thiabendazole, and prochloraz, and 1.5 μg/kg for iprodione in food matrices. The mean recoveries were in the range of 70.4-113.9% with relative standard deviations (RSDs) of less than 16.9% at three spiking levels. The measurement uncertainty of the analytical method was determined using the bottom-up approach, which yielded an average value of 7.6%. Carbendazim was most frequently found in real samples analyzed using the developed method. Consequently, the analytical method can serve as an advantageous and rapid tool for determination of five preservative pesticides in fruits and vegetables.
Lane, Jonathan A; Mariño, Karina; Rudd, Pauline M; Carrington, Stephen D; Slattery, Helen; Hickey, Rita M
2012-07-01
Many studies have demonstrated the capacity of glycan-based compounds to disrupt microbial binding to mucosal epithelia. Therefore, oligosaccharides have potential application in the prevention of certain bacterial diseases. However, current screening methods for the identification of anti-adhesive oligosaccharides have limitations: they are time-consuming and require large amounts of oligosaccharides. There is a need to develop analytical techniques which can quickly screen for, and structurally define, anti-adhesive oligosaccharides prior to using human cell line models of infection. Considering this, we have developed a rapid method for screening complex oligosaccharide mixtures for potential anti-adhesive activity against bacteria. Our approach involves the use of whole bacterial cells to "deplete" free oligosaccharides from solution. As a case study, the free oligosaccharides from the colostrum of Holstein Friesian cows were screened for interactions with whole Escherichia coli cells. Reductions in oligosaccharide concentrations were determined by High pH Anion Exchange Chromatography and Hydrophilic Interaction Liquid Chromatography (HILIC-HPLC). Oligosaccharide structures were confirmed by a combination of HILIC-HPLC, exoglycosidase digestion and off-line negative ion mode MS/MS. The depletion assay confirmed selective bacterial interaction with certain bovine oligosaccharides which in previous studies, by other methodologies, had been shown to interact with E. coli. In particular, the bacterial cells depleted the following oligosaccharides in a population dependent manner: 3'-sialyllactose, disialyllactose, and 6'-sialyllactosamine. The assay methodology was further validated by studies in which we demonstrated the inhibitory activity of 3'-sialyllactose, and a mixture of bovine colostrum oligosaccharides, on E. coli adhesion to differentiated HT-29 cells. Copyright © 2012 Elsevier B.V. All rights reserved.
Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.
Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M
2006-01-01
A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.
A review of designer anabolic steroids in equine sports.
Waller, Christopher C; McLeod, Malcolm D
2017-09-01
In recent years, the potential for anabolic steroid abuse in equine sports has increased due to the growing availability of designer steroids. These compounds are readily accessible online in 'dietary' or 'nutritional' supplements and contain steroidal compounds which have never been tested or approved as veterinary agents. They typically have unusual structures or substitution and as a result may pass undetected through current anti-doping screening protocols, making them a significant concern for the integrity of the industry. Despite considerable focus in human sports, until recently there has been limited investigation into these compounds in equine systems. To effectively respond to the threat of designer steroids, a detailed understanding of their metabolism is needed to identify markers and metabolites arising from their misuse. A summary of the literature detailing the metabolism of these compounds in equine systems is presented with an aim to identify metabolites suitable for incorporation into screening protocols by anti-doping laboratories. The future of equine anti-doping research is likely to be guided by the incorporation of alternate testing matrices into routine screening, the improvement of in vitro technologies that can mimic in vivo equine metabolism, and the improvement of instrumentation or analytical methods that allow for the development of untargeted screening, and metabolomics approaches for use in anti-doping screening protocols. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Molecular markers for colorectal cancer screening
Dickinson, Brandon T.; Kisiel, John; Ahlquist, David A.; Grady, William M.
2016-01-01
Colorectal cancer (CRC), although a significant cause of morbidity and mortality worldwide, has seen a declining incidence and mortality in countries with programmatic screening. Fecal occult blood testing (FOBT) and endoscopic approaches are the predominant screening methods currently. The discovery of the adenoma→carcinoma sequence and a greater understanding of the genetic and epigenetic changes that drive the formation of CRC have contributed to innovative research to identify molecular markers for highly accurate, non-invasive screening tests for CRC. DNA, proteins, messenger RNA, and micro-RNA have all been evaluated. The observation of tumor cell exfoliation into the mucocellular layer of the colonic epithelium and proven stability of DNA in a harsh stool environment make stool DNA a particularly promising marker. The development of a clinically useful stool DNA test has required numerous technical advances, including optimization in DNA stabilization, the development of assays with high analytical sensitivity, and the identification of specific and broadly informative molecular markers. A multi-target stool DNA (MT-sDNA) test, which combines both mutant and methylated DNA markers and a fecal immunochemical test (FIT), recently performed favorably in a large cross-sectional validation study and has been approved by the US Food and Drug Administration (FDA) for the screening of asymptomatic, average risk individuals. The ultimate way in which molecular marker screening assays will be used in clinical practice will require additional studies to determine optimal screening intervals, factors affecting compliance, management of false positive results, and the use of these assays in high-risk populations, as well as other considerations. PMID:25994221
Kim, James A; Ptolemy, Adam S; Melanson, Stacy E F; Janfaza, David R; Ross, Edgar L
2015-06-01
The urine of a patient admitted for chest and epigastric pain tested positive for cocaine using an immunoassay-based drug screening method (positive/negative cutoff concentration 150 ng/mL). Despite the patient's denial of recent cocaine use, this positive cocaine screening result in conjunction with a remote history of drug misuse impacted the patient's recommended pain therapy. Specifically, these factors prompted the clinical team to question the appropriateness of opioids and other potentially addictive therapeutics during the treatment of cancer pain from previously undetected advanced pancreatic carcinoma. After pain management and clinical pathology consultation, it was decided that the positive cocaine screening result should be confirmed by gas chromatography-mass spectrometry (GC-MS) testing. This more sensitive and specific analytical technique revealed that both cocaine and its primary metabolite benzoylecgonine were undetectable (i.e., less than the assay detection limit of 50 ng/mL), thus indicating that the positive urine screening result was falsely positive. With this confirmation, the pain management service team was reassured in offering intrathecal pump (ITP) therapy for pain control. ITP implantation was well tolerated, and the patient eventually achieved excellent pain relief. However, ITP therapy most likely would not have been utilized without the GC-MS confirmation testing unless alternative options failed and extensive vigilant monitoring was initiated. As exemplified in this case, confirmatory drug testing should be performed on specimens with unexpected immunoassay-based drug screening results. To our knowledge, this is the first report of a false-positive urine cocaine screening result and its impact on patient management. Wiley Periodicals, Inc.
Tan, Nicholas X.; Rydzak, Chara; Yang, Li-Gang; Vickerman, Peter; Yang, Bin; Peeling, Rosanna W.; Hawkes, Sarah; Chen, Xiang-Sheng; Tucker, Joseph D.
2013-01-01
Background Syphilis is a major public health problem in many regions of China, with increases in congenital syphilis (CS) cases causing concern. The Chinese Ministry of Health recently announced a comprehensive 10-y national syphilis control plan focusing on averting CS. The decision analytic model presented here quantifies the impact of the planned strategies to determine whether they are likely to meet the goals laid out in the control plan. Methods and Findings Our model incorporated data on age-stratified fertility, female adult syphilis cases, and empirical syphilis transmission rates to estimate the number of CS cases associated with prenatal syphilis infection on a yearly basis. Guangdong Province was the focus of this analysis because of the availability of high-quality demographic and public health data. Each model outcome was simulated 1,000 times to incorporate uncertainty in model inputs. The model was validated using data from a CS intervention program among 477,656 women in China. Sensitivity analyses were performed to identify which variables are likely to be most influential in achieving Chinese and international policy goals. Increasing prenatal screening coverage was the single most effective strategy for reducing CS cases. An incremental increase in prenatal screening from the base case of 57% coverage to 95% coverage was associated with 106 (95% CI: 101, 111) CS cases averted per 100,000 live births (58% decrease). The policy strategies laid out in the national plan led to an outcome that fell short of the target, while a four-pronged comprehensive syphilis control strategy consisting of increased prenatal screening coverage, increased treatment completion, earlier prenatal screening, and improved syphilis test characteristics was associated with 157 (95% CI: 154, 160) CS cases averted per 100,000 live births (85% decrease). Conclusions The Chinese national plan provides a strong foundation for syphilis control, but more comprehensive measures that include earlier and more extensive screening are necessary for reaching policy goals. Please see later in the article for the Editors' Summary PMID:23349624
From the one-bead-one-compound concept to one-bead-one-reactor.
Marani, Mariela M; Paradís-Bas, Marta; Tulla-Puche, Judit; Côté, Simón; Camperi, Silvia A; Cascone, Osvaldo; Albericio, Fernando
2007-01-01
The one-bead-one-compound method gives access to millions of compounds that can be screened directly on the bead. Although characterization techniques are increasingly potent and reliable, problems can still be encountered in deciphering the sequence of the active compound because of sensitiveness or manipulation of the bead. ChemMatrix, a totally PEG-based resin, has resolved the synthesis of peptides of outstanding difficulty. Like other PEG-based resins, it permits on-bead screening because of its compatibility in aqueous media and has the further advantage of having a high loading, comparable to polystyrene resins. ChemMatrix beads previously swelled in water can be nicely divided into four parts that can be characterized using different analytical techniques or just stored for safety or for further testing. The four bead parts show high homogeneity and can thus be considered to be replicas.
Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.
Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne
2010-01-01
Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.
Su, Xiaoye; Liang, Ruiting; Stolee, Jessica A
2018-06-05
Oligonucleotides are being researched and developed as potential drug candidates for the treatment of a broad spectrum of diseases. The characterization of antisense oligonucleotide (ASO) impurities caused by base mutations (e.g. deamination) which are closely related to the target ASO is a significant analytical challenge. Herein, we describe a novel one-step method, utilizing a strategy that combines fluorescence-ON detection with competitive hybridization, to achieve single base mutation quantitation in extensively modified synthetic ASOs. Given that this method is highly specific and sensitive (LoQ = 4 nM), we envision that it will find utility for screening other impurities as well as sequencing modified oligonucleotides. Copyright © 2018 Elsevier B.V. All rights reserved.
Automatic high-throughput screening of colloidal crystals using machine learning
NASA Astrophysics Data System (ADS)
Spellings, Matthew; Glotzer, Sharon C.
Recent improvements in hardware and software have united to pose an interesting problem for computational scientists studying self-assembly of particles into crystal structures: while studies covering large swathes of parameter space can be dispatched at once using modern supercomputers and parallel architectures, identifying the different regions of a phase diagram is often a serial task completed by hand. While analytic methods exist to distinguish some simple structures, they can be difficult to apply, and automatic identification of more complex structures is still lacking. In this talk we describe one method to create numerical ``fingerprints'' of local order and use them to analyze a study of complex ordered structures. We can use these methods as first steps toward automatic exploration of parameter space and, more broadly, the strategic design of new materials.
Influence of dense plasma on the energy levels and transition properties in highly charged ions
NASA Astrophysics Data System (ADS)
Chen, Zhan-Bin; Hu, Hong-Wei; Ma, Kun; Liu, Xiao-Bin; Guo, Xue-Ling; Li, Shuang; Zhu, Bo-Hong; Huang, Lian; Wang, Kai
2018-03-01
The studies of the influence of plasma environments on the level structures and transition properties for highly charged ions are presented. For the relativistic treatment, we implemented the multiconfiguration Dirac-Fock method incorporating the ion sphere (IS) model potential, in which the plasma screening is taken into account as a modified interaction potential between the electron and the nucleus. For the nonrelativistic treatment, analytical solutions of the Schrödinger equation with two types of the IS screened potential are proposed. The Ritz variation method is used with hydrogenic wave function as a trial wave function that contains two unknown variational parameters. Bound energies are derived from an energy equation, and the variational parameters are obtained from the minimisation condition of the expectation value of the energy. Numerical results for hydrogen-like ions in dense plasmas are presented as examples. A detailed analysis of the influence of relativistic effects on the energy levels and transition properties is also reported. Our results are compared with available results in the literature showing a good quantitative agreement.
NASA Astrophysics Data System (ADS)
Mekala, R.; Jagdish, P.; Mathammal, R.; Sangeetha, K.
2017-04-01
The cocrystal was screened by solvent drop grinding method and the crystals were grown by slow evaporation method at ambient conditions. The cocrystal formation of o-picolinic acid with p-nitro aniline was initially analysed by powder X-ray diffraction. Further the structural properties of the grown crystal were confirmed by the single X-ray diffraction which indicates that the cocrystal were connected by the strong N+sbnd H-⋯O hydrogen bond interaction. The cell parameters of the grown crystal were a = 14.2144(5) Å, b = 5.7558(2) Å, c = 16.0539(6) Å. The functional groups were identified using Fourier transform infrared and Raman spectral analysis. The excitation and emission state of the sample was analysed by the UV-Visible and Fluorescence studies. The red emission was observed from the Fluorescence studies. NMR studies revealed the chemical shift of the cocrystal. Thermal stability and its melting behaviour were studied by TGA and DSC analytical techniques. Electrical behaviour was studied using the dielectric studies. The intermolecular charge transfer within the molecule were analysed using HOMO- LUMO plots.
USDA-ARS?s Scientific Manuscript database
Danofloxacin (DANO) residue in bovine muscle was screened at 200 ng/g by terbium-sensitized luminescence (TSL) directly measured on 10x6 mm C18 sorbent strips. The analyte was first adsorbed on sorbent surface by immersion in defatted homogenates. After reagent application and desiccation, TSL was d...
Pre-Analytical Conditions in Non-Invasive Prenatal Testing of Cell-Free Fetal RHD
Rieneck, Klaus; Krog, Grethe Risum; Nielsen, Leif Kofoed; Tabor, Ann; Dziegiel, Morten Hanefeld
2013-01-01
Background Non-invasive prenatal testing of cell-free fetal DNA (cffDNA) in maternal plasma can predict the fetal RhD type in D negative pregnant women. In Denmark, routine antenatal screening for the fetal RhD gene (RHD) directs the administration of antenatal anti-D prophylaxis only to women who carry an RhD positive fetus. Prophylaxis reduces the risk of immunization that may lead to hemolytic disease of the fetus and the newborn. The reliability of predicting the fetal RhD type depends on pre-analytical factors and assay sensitivity. We evaluated the testing setup in the Capital Region of Denmark, based on data from routine antenatal RHD screening. Methods Blood samples were drawn at gestational age 25 weeks. DNA extracted from 1 mL of plasma was analyzed for fetal RHD using a duplex method for exon 7/10. We investigated the effect of blood sample transportation time (n = 110) and ambient outdoor temperatures (n = 1539) on the levels of cffDNA and total DNA. We compared two different quantification methods, the delta Ct method and a universal standard curve. PCR pipetting was compared on two systems (n = 104). Results The cffDNA level was unaffected by blood sample transportation for up to 9 days and by ambient outdoor temperatures ranging from -10°C to 28°C during transport. The universal standard curve was applicable for cffDNA quantification. Identical levels of cffDNA were observed using the two automated PCR pipetting systems. We detected a mean of 100 fetal DNA copies/mL at a median gestational age of 25 weeks (range 10–39, n = 1317). Conclusion The setup for real-time PCR-based, non-invasive prenatal testing of cffDNA in the Capital Region of Denmark is very robust. Our findings regarding the transportation of blood samples demonstrate the high stability of cffDNA. The applicability of a universal standard curve facilitates easy cffDNA quantification. PMID:24204719
2017-01-01
Eye movements provide insights into what people pay attention to, and therefore are commonly included in a variety of human-computer interaction studies. Eye movement recording devices (eye trackers) produce gaze trajectories, that is, sequences of gaze location on the screen. Despite recent technological developments that enabled more affordable hardware, gaze data are still costly and time consuming to collect, therefore some propose using mouse movements instead. These are easy to collect automatically and on a large scale. If and how these two movement types are linked, however, is less clear and highly debated. We address this problem in two ways. First, we introduce a new movement analytics methodology to quantify the level of dynamic interaction between the gaze and the mouse pointer on the screen. Our method uses volumetric representation of movement, the space-time densities, which allows us to calculate interaction levels between two physically different types of movement. We describe the method and compare the results with existing dynamic interaction methods from movement ecology. The sensitivity to method parameters is evaluated on simulated trajectories where we can control interaction levels. Second, we perform an experiment with eye and mouse tracking to generate real data with real levels of interaction, to apply and test our new methodology on a real case. Further, as our experiment tasks mimics route-tracing when using a map, it is more than a data collection exercise and it simultaneously allows us to investigate the actual connection between the eye and the mouse. We find that there seem to be natural coupling when eyes are not under conscious control, but that this coupling breaks down when instructed to move them intentionally. Based on these observations, we tentatively suggest that for natural tracing tasks, mouse tracking could potentially provide similar information as eye-tracking and therefore be used as a proxy for attention. However, more research is needed to confirm this. PMID:28777822
Demšar, Urška; Çöltekin, Arzu
2017-01-01
Eye movements provide insights into what people pay attention to, and therefore are commonly included in a variety of human-computer interaction studies. Eye movement recording devices (eye trackers) produce gaze trajectories, that is, sequences of gaze location on the screen. Despite recent technological developments that enabled more affordable hardware, gaze data are still costly and time consuming to collect, therefore some propose using mouse movements instead. These are easy to collect automatically and on a large scale. If and how these two movement types are linked, however, is less clear and highly debated. We address this problem in two ways. First, we introduce a new movement analytics methodology to quantify the level of dynamic interaction between the gaze and the mouse pointer on the screen. Our method uses volumetric representation of movement, the space-time densities, which allows us to calculate interaction levels between two physically different types of movement. We describe the method and compare the results with existing dynamic interaction methods from movement ecology. The sensitivity to method parameters is evaluated on simulated trajectories where we can control interaction levels. Second, we perform an experiment with eye and mouse tracking to generate real data with real levels of interaction, to apply and test our new methodology on a real case. Further, as our experiment tasks mimics route-tracing when using a map, it is more than a data collection exercise and it simultaneously allows us to investigate the actual connection between the eye and the mouse. We find that there seem to be natural coupling when eyes are not under conscious control, but that this coupling breaks down when instructed to move them intentionally. Based on these observations, we tentatively suggest that for natural tracing tasks, mouse tracking could potentially provide similar information as eye-tracking and therefore be used as a proxy for attention. However, more research is needed to confirm this.
Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy
2016-06-17
This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.
Screening and selection of artificial riboswitches.
Harbaugh, Svetlana V; Martin, Jennifer; Weinstein, Jenna; Ingram, Grant; Kelley-Loughnane, Nancy
2018-05-17
Synthetic riboswitches are engineered to regulate gene expression in response to a variety of non-endogenous small molecules, and a challenge to select this engineered response requires robust screening tools. A new synthetic riboswitch can be created by linking an in vitro-selected aptamer library with a randomized expression platform followed by in vivo selection and screening. In order to determine response to analyte, we developed a dual-color reporter comprising elements of the E. coli fimbriae phase variation system: recombinase FimE controlled by a synthetic riboswitch and an invertible DNA segment (fimS) containing a constitutively active promoter placed between two fluorescent protein genes. Without an analyte, the fluorescent reporter constitutively expressed green fluorescent protein (GFPa1). Addition of the analyte initiated translation of fimE causing unidirectional inversion of the fimS segment and constitutive expression of red fluorescent protein (mKate2). The dual color reporter system can be used to select and to optimize artificial riboswitches in E. coli cells. In this work, the enriched library of aptamers incorporated into the riboswitch architecture reduces the sequence search space by offering a higher percentage of potential ligand binders. The study was designed to produce structure switching aptamers, a necessary feature for riboswitch function and efficiently quantify this function using the dual color reporter system. Copyright © 2018. Published by Elsevier Inc.
A cost-effectiveness analysis of screening for silent atrial fibrillation after ischaemic stroke.
Levin, Lars-Åke; Husberg, Magnus; Sobocinski, Piotr Doliwa; Kull, Viveka Frykman; Friberg, Leif; Rosenqvist, Mårten; Davidson, Thomas
2015-02-01
The purpose of this study was to estimate the cost-effectiveness of two screening methods for detection of silent AF, intermittent electrocardiogram (ECG) recordings using a handheld recording device, at regular time intervals for 30 days, and short-term 24 h continuous Holter ECG, in comparison with a no-screening alternative in 75-year-old patients with a recent ischaemic stroke. The long-term (20-year) costs and effects of all alternatives were estimated with a decision analytic model combining the result of a clinical study and epidemiological data from Sweden. The structure of a cost-effectiveness analysis was used in this study. The short-term decision tree model analysed the screening procedure until the onset of anticoagulant treatment. The second part of the decision model followed a Markov design, simulating the patients' health states for 20 years. Continuous 24 h ECG recording was inferior to intermittent ECG in terms of cost-effectiveness, due to both lower sensitivity and higher costs. The base-case analysis compared intermittent ECG screening with no screening of patients with recent stroke. The implementation of the screening programme on 1000 patients resulted over a 20-year period in 11 avoided strokes and the gain of 29 life-years, or 23 quality-adjusted life years, and cost savings of €55 400. Screening of silent AF by intermittent ECG recordings in patients with a recent ischaemic stroke is a cost-effective use of health care resources saving costs and lives and improving the quality of life. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Cost-effectiveness of community screening for glaucoma in rural India: a decision analytical model.
John, D; Parikh, R
2018-02-01
Studies in several countries have demonstrated the cost-effectiveness of population-based screening for glaucoma when targeted at high-risk groups such as older adults and with familial history of disease. This study conducts a cost-effective analysis of a hypothetical community screening and subsequent treatment programme in comparison to opportunistic case finding for glaucoma in rural India. A hypothetical screening programme for both primary open-angle glaucoma and angle-closure disease was built for a population aged between 40 and 69 years in rural areas of India. A decision analytical model was built to model events, costs and treatment pathways with and without a hypothetical screening programme for glaucoma for a rural-based population aged between 40 and 69 years in India. The treatment pathway included both primary open-angle glaucoma and angle-closure disease. The data on costs of screening and treatment were provided by an administrator of a tertiary eye hospital in Eastern India. The probabilities for the screening and treatment pathway were derived from published literature and a glaucoma specialist. The glaucoma prevalence rates were adapted from the Chennai Glaucoma Study findings. An incremental cost-effectiveness ratio value of ₹7292.30 per quality-adjusted life-year was calculated for a community-screening programme for glaucoma in rural India. The community screening for glaucoma would treat an additional 2872 cases and prevent 2190 person-years of blindness over a 10-year period. Community screening for glaucoma in rural India appears to be cost-effective when judged by a ratio of willingness-to-pay thresholds as per WHO-CHOICE guidelines. For community screening to be cost-effective, adequate resources, such as trained medical personnel and equipment would need to be made available. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Cipriano, L E; Barth, W H; Zaric, G S
2010-08-01
To estimate the cost-effectiveness of targeted and universal screening for vasa praevia at 18-20 weeks of gestation in singleton and twin pregnancies. Cost-utility analysis based on a decision-analytic model comparing relevant strategies and life-long outcomes for mother and infant(s). Ontario, Canada. A cohort of pregnant women in 1 year. We constructed a decision-analytic model to estimate the lifetime incremental costs and benefits of screening for vasa praevia. Inputs were estimated from the literature. Costs were collected from the London Health Sciences Centre, the Ontario Health Insurance Program, and other sources. We used one-way, scenario and probabilistic sensitivity analysis to determine the robustness of the results. Incremental costs, life expectancy, quality-adjusted life-years (QALY) and incremental cost-effectiveness ratio (ICER). Universal transvaginal ultrasound screening of twin pregnancies has an ICER of $5488 per QALY-gained. Screening all singleton pregnancies with the risk factors low-lying placentas, in vitro fertilisation (IVF) conception, accessory placental lobes, or velamentous cord insertion has an ICER of $15,764 per QALY-gained even though identifying some of these risk factors requires routine use of colour Doppler during transabdominal examinations. Screening women with a marginal cord insertion costs an additional $27,603 per QALY-gained. Universal transvaginal screening for vasa praevia in singleton pregnancies costs $579,164 per QALY compared with targeted screening. Compared with current practice, screening all twin pregnancies for vasa praevia with transvaginal ultrasound is cost-effective. Among the alternatives considered, the use of colour Doppler at all transabdominal ultrasound examinations of singleton pregnancies and targeted use of transvaginal ultrasound for IVF pregnancies or when the placenta has been found to be associated with one or more risk factors is cost-effective. Universal screening of singleton pregnancies is not cost-effective compared with targeted screening.
2010-01-01
Background Alzheimer's Disease (AD) affects a growing proportion of the population each year. Novel therapies on the horizon may slow the progress of AD symptoms and avoid cases altogether. Initiating treatment for the underlying pathology of AD would ideally be based on biomarker screening tools identifying pre-symptomatic individuals. Early-stage modeling provides estimates of potential outcomes and informs policy development. Methods A time-to-event (TTE) simulation provided estimates of screening asymptomatic patients in the general population age ≥55 and treatment impact on the number of patients reaching AD. Patients were followed from AD screen until all-cause death. Baseline sensitivity and specificity were 0.87 and 0.78, with treatment on positive screen. Treatment slowed progression by 50%. Events were scheduled using literature-based age-dependent incidences of AD and death. Results The base case results indicated increased AD free years (AD-FYs) through delays in onset and a reduction of 20 AD cases per 1000 screened individuals. Patients completely avoiding AD accounted for 61% of the incremental AD-FYs gained. Total years of treatment per 1000 screened patients was 2,611. The number-needed-to-screen was 51 and the number-needed-to-treat was 12 to avoid one case of AD. One-way sensitivity analysis indicated that duration of screening sensitivity and rescreen interval impact AD-FYs the most. A two-way sensitivity analysis found that for a test with an extended duration of sensitivity (15 years) the number of AD cases avoided was 6,000-7,000 cases for a test with higher sensitivity and specificity (0.90,0.90). Conclusions This study yielded valuable parameter range estimates at an early stage in the study of screening for AD. Analysis identified duration of screening sensitivity as a key variable that may be unavailable from clinical trials. PMID:20433705
Sample, Bradley E; Fairbrother, Anne; Kaiser, Ashley; Law, Sheryl; Adams, Bill
2014-10-01
Ecological soil-screening levels (Eco-SSLs) were developed by the United States Environmental Protection Agency (USEPA) for the purposes of setting conservative soil screening values that can be used to eliminate the need for further ecological assessment for specific analytes at a given site. Ecological soil-screening levels for wildlife represent a simplified dietary exposure model solved in terms of soil concentrations to produce exposure equal to a no-observed-adverse-effect toxicity reference value (TRV). Sensitivity analyses were performed for 6 avian and mammalian model species, and 16 metals/metalloids for which Eco-SSLs have been developed. The relative influence of model parameters was expressed as the absolute value of the range of variation observed in the resulting soil concentration when exposure is equal to the TRV. Rank analysis of variance was used to identify parameters with greatest influence on model output. For both birds and mammals, soil ingestion displayed the broadest overall range (variability), although TRVs consistently had the greatest influence on calculated soil concentrations; bioavailability in food was consistently the least influential parameter, although an important site-specific variable. Relative importance of parameters differed by trophic group. Soil ingestion ranked 2nd for carnivores and herbivores, but was 4th for invertivores. Different patterns were exhibited, depending on which parameter, trophic group, and analyte combination was considered. The approach for TRV selection was also examined in detail, with Cu as the representative analyte. The underlying assumption that generic body-weight-normalized TRVs can be used to derive protective levels for any species is not supported by the data. Whereas the use of site-, species-, and analyte-specific exposure parameters is recommended to reduce variation in exposure estimates (soil protection level), improvement of TRVs is more problematic. © 2014 The Authors. Environmental Toxicology and Chemistry Published by Wiley Periodicals, Inc.
Sample, Bradley E; Fairbrother, Anne; Kaiser, Ashley; Law, Sheryl; Adams, Bill
2014-01-01
Ecological soil-screening levels (Eco-SSLs) were developed by the United States Environmental Protection Agency (USEPA) for the purposes of setting conservative soil screening values that can be used to eliminate the need for further ecological assessment for specific analytes at a given site. Ecological soil-screening levels for wildlife represent a simplified dietary exposure model solved in terms of soil concentrations to produce exposure equal to a no-observed-adverse-effect toxicity reference value (TRV). Sensitivity analyses were performed for 6 avian and mammalian model species, and 16 metals/metalloids for which Eco-SSLs have been developed. The relative influence of model parameters was expressed as the absolute value of the range of variation observed in the resulting soil concentration when exposure is equal to the TRV. Rank analysis of variance was used to identify parameters with greatest influence on model output. For both birds and mammals, soil ingestion displayed the broadest overall range (variability), although TRVs consistently had the greatest influence on calculated soil concentrations; bioavailability in food was consistently the least influential parameter, although an important site-specific variable. Relative importance of parameters differed by trophic group. Soil ingestion ranked 2nd for carnivores and herbivores, but was 4th for invertivores. Different patterns were exhibited, depending on which parameter, trophic group, and analyte combination was considered. The approach for TRV selection was also examined in detail, with Cu as the representative analyte. The underlying assumption that generic body-weight–normalized TRVs can be used to derive protective levels for any species is not supported by the data. Whereas the use of site-, species-, and analyte-specific exposure parameters is recommended to reduce variation in exposure estimates (soil protection level), improvement of TRVs is more problematic. Environ Toxicol Chem 2014;33:2386–2398. PMID:24944000
A Critical Review of Methods to Evaluate the Impact of FDA Regulatory Actions
Briesacher, Becky A.; Soumerai, Stephen B.; Zhang, Fang; Toh, Sengwee; Andrade, Susan E.; Wagner, Joann L.; Shoaibi, Azadeh; Gurwitz, Jerry H.
2013-01-01
Purpose To conduct a synthesis of the literature on methods to evaluate the impacts of FDA regulatory actions, and identify best practices for future evaluations. Methods We searched MEDLINE for manuscripts published between January 1948 and August 2011 that included terms related to FDA, regulatory actions, and empirical evaluation; the review additionally included FDA-identified literature. We used a modified Delphi method to identify preferred methodologies. We included studies with explicit methods to address threats to validity, and identified designs and analytic methods with strong internal validity that have been applied to other policy evaluations. Results We included 18 studies out of 243 abstracts and papers screened. Overall, analytic rigor in prior evaluations of FDA regulatory actions varied considerably; less than a quarter of studies (22%) included control groups. Only 56% assessed changes in the use of substitute products/services, and 11% examined patient health outcomes. Among studies meeting minimal criteria of rigor, 50% found no impact or weak/modest impacts of FDA actions and 33% detected unintended consequences. Among those studies finding significant intended effects of FDA actions, all cited the importance of intensive communication efforts. There are preferred methods with strong internal validity that have yet to be applied to evaluations of FDA regulatory actions. Conclusions Rigorous evaluations of the impact of FDA regulatory actions have been limited and infrequent. Several methods with strong internal validity are available to improve trustworthiness of future evaluations of FDA policies. PMID:23847020
NASA Astrophysics Data System (ADS)
Manganaris, George A.; Goulas, Vlasios; Mellidou, Ifigeneia; Drogoudi, Pavlina
2017-12-01
Horticultural commodities (fruit and vegetables) are the major dietary source of several bioactive compounds of high nutraceutical value for humans, including polyphenols, carotenoids and vitamins. The aim of the current review was dual. Firstly, towards the eventual enhancement of horticultural crops with bio-functional compounds, the natural genetic variation in antioxidants found in different species and cultivar/genotypes is underlined. Notably, some landraces and/or traditional cultivars have been characterized by substantially higher phytochemical content, i.e. small tomato of Santorini island (cv. ‘Tomataki Santorinis’) possesses appreciably high amounts of ascorbic acid. The systematic screening of key bioactive compounds in a wide range of germplasm for the identification of promising genotypes and the restoration of key gene fractions from wild species and landraces may help in reducing the loss of agro-biodiversity, creating a healthier ‘gene pool’ as the basis of future adaptation. Towards this direction, large scale comparative studies in different cultivars/genotypes of a given species provide useful insights about the ones of higher nutritional value. Secondly, the advancements in the employment of analytical techniques to determine the antioxidant potential through a convenient, easy and fast way are outlined. Such analytical techniques include electron paramagnetic resonance (EPR) and infrared (IR) spectroscopy, electrochemical and chemometric methods, flow injection analysis (FIA), optical sensors and high resolution screening (HRS). Taking into consideration that fruits and vegetables are complex mixtures of water- and lipid-soluble antioxidants, the exploitation of chemometrics to develop “omics” platforms (i.e. metabolomics, foodomics) is a promising tool for researchers to decode and/or predict antioxidant activity of fresh produce. For industry, the use of cheap and rapid optical sensors and IR spectroscopy is recommended to estimate the antioxidant activity, hence legislation does not allow its correlation with health claims.
Manganaris, George A; Goulas, Vlasios; Mellidou, Ifigeneia; Drogoudi, Pavlina
2017-01-01
Horticultural commodities (fruit and vegetables) are the major dietary source of several bioactive compounds of high nutraceutical value for humans, including polyphenols, carotenoids and vitamins. The aim of the current review was dual. Firstly, toward the eventual enhancement of horticultural crops with bio-functional compounds, the natural genetic variation in antioxidants found in different species and cultivars/genotypes is underlined. Notably, some landraces and/or traditional cultivars have been characterized by substantially higher phytochemical content, i.e., small tomato of Santorini island (cv. "Tomataki Santorinis") possesses appreciably high amounts of ascorbic acid (AsA). The systematic screening of key bioactive compounds in a wide range of germplasm for the identification of promising genotypes and the restoration of key gene fractions from wild species and landraces may help in reducing the loss of agro-biodiversity, creating a healthier "gene pool" as the basis of future adaptation. Toward this direction, large scale comparative studies in different cultivars/genotypes of a given species provide useful insights about the ones of higher nutritional value. Secondly, the advancements in the employment of analytical techniques to determine the antioxidant potential through a convenient, easy and fast way are outlined. Such analytical techniques include electron paramagnetic resonance (EPR) and infrared (IR) spectroscopy, electrochemical, and chemometric methods, flow injection analysis (FIA), optical sensors, and high resolution screening (HRS). Taking into consideration that fruits and vegetables are complex mixtures of water- and lipid-soluble antioxidants, the exploitation of chemometrics to develop "omics" platforms (i.e., metabolomics, foodomics) is a promising tool for researchers to decode and/or predict antioxidant activity of fresh produce. For industry, the use of optical sensors and IR spectroscopy is recommended to estimate the antioxidant activity rapidly and at low cost, although legislation does not allow its correlation with health claims.
Mahmoud, Bahaa G; Khairy, Mohamed; Rashwan, Farouk A; Banks, Craig E
2017-02-07
To overcome the recent outbreaks of hepatotoxicity-related drugs, a new analytical tool for the continuously determination of these drugs in human fluids is required. Electrochemical-based analytical methods offer an effective, rapid, and simple tool for on-site determination of various organic and inorganic species. However, the design of a sensitive, selective, stable, and reproducible sensor is still a major challenge. In the present manuscript, a facile, one-pot hydrothermal synthesis of bismuth oxide (Bi 2 O 2.33 ) nanostructures (nanorods) was developed. These BiO nanorods were cast onto mass disposable graphite screen-printed electrodes (BiO-SPEs), allowing the ultrasensitive determination of acetaminophen (APAP) in the presence of its common interference isoniazid (INH), which are both found in drug samples. The simultaneous electroanalytical sensing using BiO-SPEs exhibited strong electrocatalytic activity toward the sensing of APAP and INH with an enhanced analytical signal (voltammetric peak) over that achievable at unmodified (bare) SPEs. The electroanalytical sensing of APAP and INH are possible with accessible linear ranges from 0.5 to 1250 μM and 5 to 1760 μM with limits of detection (3σ) of 30 nM and 1.85 μM, respectively. The stability, reproducibility, and repeatability of BiO-SPE were also investigated. The BiO-SPEs were evaluated toward the sensing of APAP and INH in human serum, urine, saliva, and tablet samples. The results presented in this paper demonstrate that BiO-SPEs sensing platforms provide a potential candidate for the accurate determination of APAP and INH within human fluids and pharmaceutical formulations.
Liu, Ying; Uboh, Cornelius E; Soma, Lawrence R; Li, Xiaoqing; Guan, Fuyu; You, Youwen; Chen, Jin-Wen
2011-09-01
Multiple drug target analysis (MDTA) used in doping control is more efficient than single drug target analysis (SDTA). The number of drugs with the potential for abuse is so extensive that full coverage is not possible with SDTA. To address this problem, a liquid chromatography tandem mass spectrometric method was developed for simultaneous analysis of 302 drugs using a scheduled multiple reaction monitoring (s-MRM) algorithm. With a known retention time of an analyte, the s-MRM algorithm monitors each MRM transition only around its expected retention time. Analytes were recovered from plasma by liquid-liquid extraction. Information-dependent acquisition (IDA) functionality was used to combine s-MRM with enhanced product ion (EPI) scans within the same chromatographic analysis. An EPI spectrum library was also generated for rapid identification of analytes. Analysis time for the 302 drugs was 7 min. Scheduled MRM improved the quality of the chromatograms, signal response, reproducibility, and enhanced signal-to-noise ratio (S/N), resulting in more data points. Reduction in total cycle time from 2.4 s in conventional MRM (c-MRM) to 1 s in s-MRM allowed completion of the EPI scan at the same time. The speed for screening and identification of multiple drugs in equine plasma for doping control analysis was greatly improved by this method.
Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona
2016-09-10
A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.
Meyer, Markus R; Caspar, Achim; Brandt, Simon D; Maurer, Hans H
2014-01-01
The first synthetic tryptamines have entered the designer drug market in the late 1990s and were distributed as psychedelic recreational drugs. In the meantime, several analogs have been brought onto the market indicating a growing interest in this drug class. So far, only scarce analytical data were available on the detectability of tryptamines in human biosamples. Therefore, the aim of the presented study was the development and full validation of a method for their detection in human urine and plasma and their quantification in human plasma. The liquid chromatography-linear ion trap mass spectrometry method presented covered 37 tryptamines as well as five β-carbolines, ibogaine, and yohimbine. Compounds were analyzed after protein precipitation of urine or fast liquid-liquid extraction of plasma using an LXQ linear ion trap coupled to an Accela ultra ultra high-performance liquid chromatography system. Data mining was performed via information-dependent acquisition or targeted product ion scan mode with positive electrospray ionization. The assay was selective for all tested substances with limits of detection in urine between 10 and 100 ng/mL and in plasma between 1 and 100 ng/mL. A validated quantification in plasma according to international recommendation could be demonstrated for 33 out of 44 analytes.
Magnetic Frequency Response of HL-LHC Beam Screens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrone, M.; Martino, M.; De Maria, R.
Magnetic fields used to control particle beams in accelerators are usually controlled by regulating the electrical current of the power converters. In order to minimize lifetime degradation and ultimately luminosity loss in circular colliders, current-noise is a highly critical figure of merit of power converters, in particular for magnets located in areas with high beta-function, like the High Luminosity Large Hadron Collider (HL-LHC) insertions. However, what is directly acting upon the beam is the magnetic field and not the current of the power converter, which undergoes several frequency-dependent transformations until the desired magnetic field, seen by the beam, is obtained.more » Beam screens are very rarely considered when assessing or specifying the noise figure of merit, but their magnetic frequency response is such that they realize relatively effective low pass filtering of the magnetic field produced by the system magnet-power converter. This work aims at filling this gap by quantifying the expected impact of different beam screen layouts for the most relevant HL-LHC insertion magnets. A welldefined post-processing technique is used to derive the frequency response of the different multipoles from multi-physics Finite Element Method (FEM) simulation results. In addition, a well approximated analytical formula for the low-frequency range of multi-layered beam screens is presented.« less
Breast cancer services in Vietnam: a scoping review
Jenkins, Chris; Minh, Luu Ngoc; Anh, Tran Tuan; Ngan, Tran Thu; Tuan, Ngo Tri; Giang, Kim Bao; Hoat, Luu Ngoc; Lohfeld, Lynne; Donnelly, Michael; Van Minh, Hoang; Murray, Liam
2018-01-01
ABSTRACT Background: Breast cancer incidence has been increasing consistently in Vietnam. Thus far, there have been no analytical reviews of research produced within this area. Objectives: We sought to analyse the nature andextent of empirical studies about breast cancer in Vietnam, identifying areas for future research and systemsstrengthening. Methods: We undertook a scoping study using a five-stage framework to review published and grey literature in English and Vietnamese on breast cancer detection, diagnosis and treatment. We focused specifically on research discussing the health system and service provision. Results: Our results show that breast cancer screening is limited, with no permanent or integrated national screening activities. There is a lack of information on screening processes and on the integration of screening services with other areas of the health system. Treatment is largely centralised, and across all services there is a lack of evaluation and data collection that would be informative for recommendations seeking to improve accessibility and quality of breast cancer services. Conclusions: This paper is the first scoping review of breast cancer services in Vietnam. It outlines areas for future focus for policy makers and researchers with the objective of strengthening service provision to women with breast cancer across the country while also providing a methodological example for how to conduct a collaborative scoping review. PMID:29473488
DOE Office of Scientific and Technical Information (OSTI.GOV)
Femec, D.A.
This report describes two code-generating tools used to speed design and implementation of relational databases and user interfaces: CREATE-SCHEMA and BUILD-SCREEN. CREATE-SCHEMA produces the SQL commands that actually create and define the database. BUILD-SCREEN takes templates for data entry screens and generates the screen management system routine calls to display the desired screen. Both tools also generate the related FORTRAN declaration statements and precompiled SQL calls. Included with this report is the source code for a number of FORTRAN routines and functions used by the user interface. This code is broadly applicable to a number of different databases.
NASA Technical Reports Server (NTRS)
Sakata, I. F.; Davis, G. W.
1975-01-01
The design of an economically viable supersonic cruise aircraft requires the lowest attainable structural-mass fraction commensurate with the selected near-term structural material technology. To achieve this goal of minimum structural-mass fraction, various combinations of promising wing and fuselage primary structure were analyzed for the load-temperature environment applicable to the arrow wing configuration. This analysis was conducted in accordance with the design criteria specified and included extensive use of computer-aided analytical methods to screen the candidate concepts and select the most promising concepts for the in-depth structural analysis.
Affinity+: Semi-Structured Brainstorming on Large Displays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burtner, Edwin R.; May, Richard A.; Scarberry, Randall E.
2013-04-27
Affinity diagraming is a powerful method for encouraging and capturing lateral thinking in a group environment. The Affinity+ Concept was designed to improve the collaborative brainstorm process through the use of large display surfaces in conjunction with mobile devices like smart phones and tablets. The system works by capturing the ideas digitally and allowing users to sort and group them on a large touch screen manually. Additionally, Affinity+ incorporates theme detection, topic clustering, and other processing algorithms that help bring structured analytic techniques to the process without requiring explicit leadership roles and other overhead typically involved in these activities.
NASA Astrophysics Data System (ADS)
Yıldız, Fehmiye; Kurt, Hamza
2017-09-01
It is well known that atmospheric turbulence severely limits the applications based on the laser propagation though the atmosphere. The most common disturbances occurring due to the atmospheric turbulence are beam spreading, beam wandering, and scintillation. These effects are continuously changing in response to atmospheric conditions. In this study, we create a Non-Kolmogorov turbulence model which is based on the geometrical optics approximation and the property of Gamma function and integrate with in Gaussian beam analytically. This approach helps us to understand the propagation of the laser beam at different wavelengths in the atmospheric turbulence.
Sverko, Ed
2006-01-01
Analytical methods for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) are widely available and are the result of a vast amount of environmental analytical method development and research on persistent organic pollutants (POPs) over the past 30–40 years. This review summarizes procedures and examines new approaches for extraction, isolation, identification and quantification of individual congeners/isomers of the PCBs and OCPs. Critical to the successful application of this methodology is the collection, preparation, and storage of samples, as well as specific quality control and reporting criteria, and therefore these are also discussed. With the signing of the Stockholm convention on POPs and the development of global monitoring programs, there is an increased need for laboratories in developing countries to determine PCBs and OCPs. Thus, while this review attempts to summarize the current best practices for analysis of PCBs and OCPs, a major focus is the need for low-cost methods that can be easily implemented in developing countries. A “performance based” process is described whereby individual laboratories can adapt methods best suited to their situations. Access to modern capillary gas chromatography (GC) equipment with either electron capture or low-resolution mass spectrometry (MS) detection to separate and quantify OCP/PCBs is essential. However, screening of samples, especially in areas of known use of OCPs or PCBs, could be accomplished with bioanalytical methods such as specific commercially available enzyme-linked immunoabsorbent assays and thus this topic is also reviewed. New analytical techniques such two-dimensional GC (2D-GC) and “fast GC” using GC–ECD may be well-suited for broader use in routine PCB/OCP analysis in the near future given their relatively low costs and ability to provide high-resolution separations of PCB/OCPs. Procedures with low environmental impact (SPME, microscale, low solvent use, etc.) are increasingly being used and may be particularly suited to developing countries. Electronic supplementary material Supplementary material is available in the online version of this article at http://dx.doi.org/10.1007/s00216-006-0765-y and is accessible for authorized users. PMID:17047943
Murphy, Malia S Q; Hawken, Steven; Atkinson, Katherine M; Milburn, Jennifer; Pervin, Jesmin; Gravett, Courtney; Stringer, Jeffrey S A; Rahman, Anisur; Lackritz, Eve; Chakraborty, Pranesh; Wilson, Kumanan
2017-01-01
Background Knowledge of gestational age (GA) is critical for guiding neonatal care and quantifying regional burdens of preterm birth. In settings where access to ultrasound dating is limited, postnatal estimates are frequently used despite the issues of accuracy associated with postnatal approaches. Newborn metabolic profiles are known to vary by severity of preterm birth. Recent work by our group and others has highlighted the accuracy of postnatal GA estimation algorithms derived from routinely collected newborn screening profiles. This protocol outlines the validation of a GA model originally developed in a North American cohort among international newborn cohorts. Methods Our primary objective is to use blood spot samples collected from infants born in Zambia and Bangladesh to evaluate our algorithm’s capacity to correctly classify GA within 1, 2, 3 and 4 weeks. Secondary objectives are to 1) determine the algorithm's accuracy in small-for-gestational-age and large-for-gestational-age infants, 2) determine its ability to correctly discriminate GA of newborns across dichotomous thresholds of preterm birth (≤34 weeks, <37 weeks GA) and 3) compare the relative performance of algorithms derived from newborn screening panels including all available analytes and those restricted to analyte subsets. The study population will consist of infants born to mothers already enrolled in one of two preterm birth cohorts in Lusaka, Zambia, and Matlab, Bangladesh. Dried blood spot samples will be collected and sent for analysis in Ontario, Canada, for model validation. Discussion This study will determine the validity of a GA estimation algorithm across ethnically diverse infant populations and assess population specific variations in newborn metabolic profiles. PMID:29104765
Jobelius, Carsten; Frimmel, Fritz H; Zwiener, Christian
2014-05-01
The anaerobic microbial degradation of aromatic and heterocyclic compounds is a prevalent process in contaminated groundwater systems. The introduction of functional groups into the contaminant molecules often results in aromatic and heterocyclic and succinic acids. These metabolites can be used as indicators for prevailing degradation processes. Therefore, there is a strong interest in developing analytical methods for screening and identification of these metabolites. In this study, neutral loss scans (NLS) by liquid chromatography-electrospray ionization/tandem mass spectrometry with losses of CO2 (NL ∆m/z = 44) and C2H4(CO2)2 (NL ∆m/z = 116) were applied for the first time successfully to screen selectively for acidic and succinic metabolites of aromatic and heterocyclic contaminants in two fulvic acid fractions from a contaminated site and a downstream region of a tar oil-polluted groundwater. Identification of these preselected signals was performed by high-resolution mass spectrometry with a liquid chromatography-electrospray ionization quadrupole time-of-flight mass spectrometry instrument. High-resolution mass and mass fragmentation data were then compared with a list of known metabolites from a literature search or matched with chemical databases supported with in silico fragmentation. Based on authentic analytical standards, several compounds from NLS were identified (e.g., 4-hydroxy-3-methylbenzoic acid, benzylsuccinic acid, naphthyl-2-methylsuccinic acid, 2-carboxyindane, and 2-carboxybenzothiophene) and tentatively identified (e.g., benzofuranmethylsuccinic acid and dihydrocarboxybenzothiophene) as aromatic, phenolic, heterocyclic, and succinic acids. The acidic metabolites were found exclusively in the contaminated region of the aquifer which indicates active biodegradation processes and no relevant occurrence of acidic metabolites in the downstream region.
Setiawan, Didik; Kotsopoulos, Nikolaos; Wilschut, Jan C; Postma, Maarten J; Connolly, Mark P
2016-01-01
Cervical cancer poses a substantial burden in terms of morbidity, mortality, and economic losses, especially in low/middle-income countries. HPV vaccination and/or cervical cancer screening among females may reduce the burden of HPV-related diseases, including cervical cancer. However, limited funds may impede the implementation of population-based programmes. Governmental investments in the prevention of infectious disease may have broader economic and fiscal benefits, which are not accounted in conventional economic analyses. This study estimates the broader economic and fiscal impacts of implementing HPV vaccination and/or cervical cancer screening in Indonesia from the perspective of the government. A government-perspective quantitative analytic framework was applied to assess the Net Present Value (NPV) of investment on cervical cancer prevention strategies including HPV vaccination, cervical screening and its combination in Indonesia. All monetary values were presented in International Dollars (I$). Based on a cohort of 10,000,000 Indonesian 12-year-old females, it was estimated that HPV vaccination and/or cervical cancer screening result in a positive NPV for the Indonesian government. The combination of cervical screening and HPV vaccination generated a substantial reduction of cervical cancer incidence and HPV-related mortality of 87,862 and 19,359, respectively. It was estimated that HPV vaccination in combination with cervical screening is the most favorable option for cervical cancer prevention (NPV I$2.031.786.000), followed by HPV vaccination alone (NPV I$1.860.783.000) and cervical screening alone (NPV I$375.244.000). In addition to clinical benefits, investing in HPV vaccination and cervical screening may yield considerable fiscal benefits for the Indonesian governments due to lifelong benefits resulting from reduction of cervical cancer-related morbidity and mortality.
König, H H; Barry, J C; Leidl, R; Zrenner, E
2000-04-01
Orthoptic screening in the kindergarten is one option to improve early detection of amblyopia in children aged 3 years. The purpose of this study was to analyse the cost-effectiveness of such a screening programme in Germany. Based on data from the literature and own experience gained from orthoptic screening in kindergarten a decision-analytic model was developed. According to the model, all children in kindergarten, aged 3 years, who had not been treated for amblyopia before, were subjected to an orthoptic examination. Non-cooperative children were reexamined in kindergarten after one year. Children with positive test results were examined by an ophthalmologist for diagnosis. Effects were measured by the number of newly diagnosed cases of amblyopia, non-obvious strabismus and amblyogenic refractive errors. Direct costs were estimated from a third-party payer perspective. The influence of uncertain model parameters was tested by sensitivity analysis. In the base analysis the cost per orthoptic screening test was DM 15.39. Examination by an ophthalmologist cost DM 71.20. The total cost of the screening programme in all German kindergartens was DM 6.1 million. With a 1.5% age-specific prevalence of undiagnosed cases, a sensitivity of 95% and a specificity of 98%, a total of 4,261 new cases would be detected. The cost-effectiveness ratio was DM 1,421 per case detected. Sensitivity analysis showed considerable influence of prevalence and specificity on the cost-effectiveness ratio. It was more cost-effective to re-screen non-cooperative children in kindergarten than to have them examined by an ophthalmologist straight-away. The decision-analytic model showed stable results which may serve as a basis for discussion on the implementation of orthoptic screening and for planning a field study.
Fiori, Jessica; Andrisano, Vincenza
2014-03-01
A screening method based on liquid chromatography-electrospray mass spectrometry for the simultaneous determination of six corticosteroids (betamethasone 17-valerate BM 17-V, beclomethasone BC, beclomethasone dipropionate BCDP, methylprednisolone MP, budesonide BD, flunisolide FN) was developed in order to control their illegal use in cosmetic and natural products. Indeed, despite corticosteroids are banned in cosmetics, counterfeit products might be present on the market, representing a health hazard. Therefore, effective analytical methods are required to rapidly screen over the counter products in health care shops for counterfeit corticosteroids. The analytical method involves the employment of a Waters Synergy C18 column (150mm×2.0mm I.D.) by using the following mobile phase: A (0.1% formic acid in acetonitrile), B (0.1% formic acid in water) in a linear gradient (from A-B 25:75, v/v to A-B 95:5, v/v in 30min) at the flow rate of 0.3mL/min. The detection was performed with an ion trap (IT) mass spectrometer in positive polarity, total ion current (TIC) and tandem mass modalities for qualitative purpose; single ion monitoring (SIM) mode was used for quantitative analysis on the ESI generated most abundant ion for each steroid. The method was fully validated in terms of precision, detection and quantification limits, linearity, recovery, and it was applied to the identification and quantification of corticosteroids in pharmaceutical formulations and cosmetic products. The mean recovery of BM 17-V, BC, BCDP, MP, BD and FN were found to be 101.3, 101.5, 98.8, 98.9, 98.1, 99.0%, respectively. Limits of quantitation (LOQ) were comprised in the range 29-95ng/mL. To the best of our knowledge, for the first time this mix of glucocorticoids were simultaneously determined in cosmetic products by using a fully validated method. BMV, in its two isomeric forms BM 17-V and BM 21-V, was found to be illegally present in one cream sample (A) with the total concentration level of 0.036% (w/w). Copyright © 2014 Elsevier B.V. All rights reserved.
Altimari, Annalisa; de Biase, Dario; De Maglio, Giovanna; Gruppioni, Elisa; Capizzi, Elisa; Degiovanni, Alessio; D’Errico, Antonia; Pession, Annalisa; Pizzolitto, Stefano; Fiorentino, Michelangelo; Tallini, Giovanni
2013-01-01
Detection of KRAS mutations in archival pathology samples is critical for therapeutic appropriateness of anti-EGFR monoclonal antibodies in colorectal cancer. We compared the sensitivity, specificity, and accuracy of Sanger sequencing, ARMS-Scorpion (TheraScreen®) real-time polymerase chain reaction (PCR), pyrosequencing, chip array hybridization, and 454 next-generation sequencing to assess KRAS codon 12 and 13 mutations in 60 nonconsecutive selected cases of colorectal cancer. Twenty of the 60 cases were detected as wild-type KRAS by all methods with 100% specificity. Among the 40 mutated cases, 13 were discrepant with at least one method. The sensitivity was 85%, 90%, 93%, and 92%, and the accuracy was 90%, 93%, 95%, and 95% for Sanger sequencing, TheraScreen real-time PCR, pyrosequencing, and chip array hybridization, respectively. The main limitation of Sanger sequencing was its low analytical sensitivity, whereas TheraScreen real-time PCR, pyrosequencing, and chip array hybridization showed higher sensitivity but suffered from the limitations of predesigned assays. Concordance between the methods was k = 0.79 for Sanger sequencing and k > 0.85 for the other techniques. Tumor cell enrichment correlated significantly with the abundance of KRAS-mutated deoxyribonucleic acid (DNA), evaluated as ΔCt for TheraScreen real-time PCR (P = 0.03), percentage of mutation for pyrosequencing (P = 0.001), ratio for chip array hybridization (P = 0.003), and percentage of mutation for 454 next-generation sequencing (P = 0.004). Also, 454 next-generation sequencing showed the best cross correlation for quantification of mutation abundance compared with all the other methods (P < 0.001). Our comparison showed the superiority of next-generation sequencing over the other techniques in terms of sensitivity and specificity. Next-generation sequencing will replace Sanger sequencing as the reference technique for diagnostic detection of KRAS mutation in archival tumor tissues. PMID:23950653
Meyer, M.T.; Bumgarner, J.E.; Varns, J.L.; Daughtridge, J.V.; Thurman, E.M.; Hostetler, K.A.
2000-01-01
Approximately one-half of the 50 000000 lb of antibiotics produced in the USA are used in agriculture. Because of the intensive use of antibiotics in the management of confined livestock operations, the potential exists for the transport of these compounds and their metabolites into our nation's water resources. A commercially available radioimmunoassay method, developed as a screen for tetracycline antibiotics in serum, urine, milk, and tissue, was adapted to analyze water samples at a detection level of approximately 1.0 ppb and a semiquantitative analytical range of 1-20 ppb. Liquid waste samples were obtained from 13 hog lagoons in three states and 52 surface- and ground-water samples were obtained primarily from areas associated with intensive swine and poultry production in seven states. These samples were screened for the tetracycline antibiotics by using the modified radioimmunoassay screening method. The radioimmunoassay tests yielded positive results for tetracycline antibiotics in samples from all 13 of the hog lagoons. Dilutions of 10-100-fold of the hog lagoon samples indicated that tetracycline antibiotic concentrations ranged from approximately 5 to several hundred parts per billion in liquid hog lagoon waste. Of the 52 surface- and ground-water samples collected all but two tested negative and these two samples contained tetracycline antibiotic concentrations less than 1 ppb. A new liquid chromatography/mass spectrometry method was used to confirm the radioimmunoassay results in 9 samples and also to identify the tetracycline antibiotics to which the radioimmunoassay test was responding. The new liquid chromatography/mass spectrometry method with online solid-phase extraction and a detection level of 0.5 ??g/l confirmed the presence of chlorotetracycline in the hog lagoon samples and in one of the surface-water samples. The concentrations calculated from the radioimmunoassay were a factor of 1-5 times less than those calculated by the liquid chromatography/mass spectrometry concentrations for chlorotetracycline. Copyright (C) 2000 Elsevier Science B.V.
Methods for detecting additional genes underlying Alzheimer disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Locke, P.A.; Haines, J.L.; Ter-Minassian, M.
1994-09-01
Alzheimer`s disease (AD) is a complex inherited disorder with proven genetic heterogeneity. To date, genes on chromosome 21 (APP) and 14 (not yet identified) are associated with early-onset familial AD, while the APOE gene on chromosome 19 is associated with both late onset familial and sporadic AD and early onset sporadic AD. Although these genes likely account for the majority of AD, many familial cases cannot be traced to any of these genes. From a set of 127 late-onset multiplex families screened for APOE, 43 (34%) families have at least one affected individual with no APOE-4 allele, suggesting an alternativemore » genetic etiology. Simulation studies indicated that additional loci could be identified through a genomic screen with a 10 cM sieve on a subset of 21 well documented, non-APOE-4 families. Given the uncertainties in the mode of inheritance, reliance on a single analytical method could result in a missed linkage. Therefore, we have developed a strategy of using multiple overlapping yet complementary methods to detect linkage. These include sib-pair analysis and affected-pedigree-member analysis, neither of which makes assumptions about mode of inheritance, and lod score analysis (using two predefined genetic models). In order for a marker to qualify for follow-up, it must fit at least two of three criteria. These are nominal P values of 0.05 or less for the non-parametric methods, and/or a lod score greater than 1.0. Adjacent markers each fulfilling a single criterion also warrant follow-up. To date, we have screened 61 markers on chromosomes 1, 2, 3, 18, 19, 21, and 22. One marker, D2S163, generated a lod score of 1.06 ({theta} = 0.15) and an APMT statistic of 3.68 (P < 0.001). This region is currently being investigated in more detail. Updated results of this region plus additional screening data will be presented.« less
Miao, Meng; Zhao, Gaosheng; Xu, Li; Dong, Junguo; Cheng, Ping
2018-03-01
A direct analytical method based on spray-inlet microwave plasma torch tandem mass spectrometry was applied to simultaneously determine 4 phthalate esters (PAEs), namely, benzyl butyl phthalate, diethyl phthalate, dipentyl phthalate, and dodecyl phthalate with extremely high sensitivity in spirits without sample treatment. Among the 4 brands of spirit products, 3 kinds of PAE compounds were directly determined at very low concentrations from 1.30 to 114 ng·g -1 . Compared with other online and off-line methods, the spray-inlet microwave plasma torch tandem mass spectrometry technique is extremely simple, rapid, sensitive, and high efficient, providing an ideal screening tool for PAEs in spirits. Copyright © 2017 John Wiley & Sons, Ltd.
[Diagnosing imported helminthiasis].
Pardo, Javier; Pérez-Arellano, José Luis; Galindo, Inmaculada; Belhassen, Moncef; Cordero, Miguel; Muro, Antonio
2007-05-01
In recent years, there has been an increase in cases of imported helminthiasis in Spain because of two complementary causes: immigration and international travel. Although the prevalence of helminthiasis is high in the immigrant population, the risk of transmission to the Spanish population is low. In this review, we provide clues to aid in the diagnosis of the helminthiasis, highlighting the geographic characteristics, clinical findings and analytical results of the most frequent types. The low sensitivity of the classic parasitological diagnostic test, mainly in tissue helminthiasis, is described. In addition, the advantages and limitations of the common serological methods for detecting related circulating antigens and antibodies are presented. Certain molecular methods used in the diagnosis of imported helminthiasis and the best strategies for screening of this condition are discussed.
Manufacturing methods and applications of membranes in microfluidics.
Chen, Xueye; Shen, Jienan; Hu, Zengliang; Huo, Xuyao
2016-12-01
Applications of membranes in microfluidics solved many thorny problems for analytical chemistry and bioscience, so that the use of membranes in microfluidics has been a topic of growing interest. Many different examples have been reported, demonstrating the versatile use of membranes. This work reviews a lot of applications of membranes in microfluidics. Membranes in microfluidics for applications including chemical reagents detection, gas detection, drug screening, cell, protein, microreactor, electrokinetical fluid, pump and valve and fluid transport control and so on, have been analyzed and discussed. In addition, the definition and basic concepts of membranes are summed up. And the methods of manufacturing membranes in microfluidics are discussed. This paper will provide a helpful reference to researchers who want to study applications of membranes in microfluidics.
ERIC Educational Resources Information Center
Dowdy, Erin; Chin, Jenna K.; Twyford, Jennifer M.; Dever, Bridget V.
2011-01-01
The Behavior Assessment System for Children, Second Edition (BASC-2) Behavioral and Emotional Screening System Parent Form (BESS Parent; Kamphaus & Reynolds, 2007) is a recently developed instrument designed to identify behavioral and emotional risk in students. To describe the underlying factor structure for this instrument, exploratory (EFA)…
NASA Astrophysics Data System (ADS)
Monti, Alessio; Toscano, Alessandro; Bilotti, Filiberto
2017-06-01
The introduction of nanoparticles-based screens [C. W. Hsu, Nat. Commun. 5, 3152 (2014)] has paved the way to the realization of low-cost transparent displays with a wide viewing angle and scalability to large size. Despite the huge potentialities of this approach, the design of a nanoparticles array exhibiting a sharp scattering response in the optical spectrum is still a challenging task. In this manuscript, we investigate the suitability of ellipsoidal plasmonic nanoparticles for this purpose. First, we show that some trade-offs between the sharpness of the scattering response of the array and its absorption level apply. Starting from these considerations, we prove that prolate nanoparticles may be a plausible candidate for achieving the peculiar features required in transparent screen applications. An example of a full-color and almost-isotropic transparent screen is finally proposed and its robustness towards the geometrical inaccuracies that may arise during the fabrication process is assessed. All the analytical considerations, carried out through an analytical model taking into account the surface dispersion effect affecting the nanoparticles, are supported by a proper set of full-wave simulations.
NASA Technical Reports Server (NTRS)
Cady, E. C.
1973-01-01
A comprehensive analytical and experimental program was performed to determine the feasibility of integrating an internal thermodynamic vent system and a full wall-screen liner for the orbital storage and transfer of liquid hydrogen (LH2). Ten screens were selected from a comprehensive screen survey. The experimental study determined the screen bubble point, flow-through pressure loss, and pressure loss along rectangular channels lined with screen on one side, for the 10 screens using LH2 saturated at 34.5 N/cm2 (50 psia). The correlated experimental data were used in an analysis to determine the optimum system characteristics in terms of minimum weight for 6 tanks ranging from 141.6 m3 (5,000 ft3) to 1.416 m3 (50 ft3) for orbital storage times of 30 and 300 days.
Monte-Carlo simulation of spatial resolution of an image intensifier in a saturation mode
NASA Astrophysics Data System (ADS)
Xie, Yuntao; Wang, Xi; Zhang, Yujun; Sun, Xiaoquan
2018-04-01
In order to investigate the spatial resolution of an image intensifier which is irradiated by high-energy pulsed laser, a three-dimensional electron avalanche model was built and the cascade process of the electrons was numerically simulated. The influence of positive wall charges, due to the failure of replenishing charges extracted from the channel during the avalanche, was considered by calculating its static electric field through particle-in-cell (PIC) method. By tracing the trajectory of electrons throughout the image intensifier, the energy of the electrons at the output of the micro channel plate and the electron distribution at the phosphor screen are numerically calculated. The simulated energy distribution of output electrons are in good agreement with experimental data of previous studies. In addition, the FWHM extensions of the electron spot at phosphor screen as a function of the number of incident electrons are calculated. The results demonstrate that the spot size increases significantly with the increase in the number of incident electrons. Furthermore, we got the MTFs of the image intensifier by Fourier transform of a point spread function at phosphor screen. Comparison between the MTFs in our model and the MTFs by analytic method shows that spatial resolution of the image intensifier decreases significantly as the number of incident electrons increases, and it is particularly obvious when incident electron number greater than 100.
Khurana, Rajneet Kaur; Rao, Satish; Beg, Sarwar; Katare, O P; Singh, Bhupinder
2016-01-01
The present work aims at the systematic development of a simple, rapid and highly sensitive densitometry-based thin-layer chromatographic method for the quantification of mangiferin in bioanalytical samples. Initially, the quality target method profile was defined and critical analytical attributes (CAAs) earmarked, namely, retardation factor (Rf), peak height, capacity factor, theoretical plates and separation number. Face-centered cubic design was selected for optimization of volume loaded and plate dimensions as the critical method parameters selected from screening studies employing D-optimal and Plackett-Burman design studies, followed by evaluating their effect on the CAAs. The mobile phase containing a mixture of ethyl acetate : acetic acid : formic acid : water in a 7 : 1 : 1 : 1 (v/v/v/v) ratio was finally selected as the optimized solvent for apt chromatographic separation of mangiferin at 262 nm withRf 0.68 ± 0.02 and all other parameters within the acceptance limits. Method validation studies revealed high linearity in the concentration range of 50-800 ng/band for mangiferin. The developed method showed high accuracy, precision, ruggedness, robustness, specificity, sensitivity, selectivity and recovery. In a nutshell, the bioanalytical method for analysis of mangiferin in plasma revealed the presence of well-resolved peaks and high recovery of mangiferin. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Performance characterization of a combined material identification and screening algorithm
NASA Astrophysics Data System (ADS)
Green, Robert L.; Hargreaves, Michael D.; Gardner, Craig M.
2013-05-01
Portable analytical devices based on a gamut of technologies (Infrared, Raman, X-Ray Fluorescence, Mass Spectrometry, etc.) are now widely available. These tools have seen increasing adoption for field-based assessment by diverse users including military, emergency response, and law enforcement. Frequently, end-users of portable devices are non-scientists who rely on embedded software and the associated algorithms to convert collected data into actionable information. Two classes of problems commonly encountered in field applications are identification and screening. Identification algorithms are designed to scour a library of known materials and determine whether the unknown measurement is consistent with a stored response (or combination of stored responses). Such algorithms can be used to identify a material from many thousands of possible candidates. Screening algorithms evaluate whether at least a subset of features in an unknown measurement correspond to one or more specific substances of interest and are typically configured to detect from a small list potential target analytes. Thus, screening algorithms are much less broadly applicable than identification algorithms; however, they typically provide higher detection rates which makes them attractive for specific applications such as chemical warfare agent or narcotics detection. This paper will present an overview and performance characterization of a combined identification/screening algorithm that has recently been developed. It will be shown that the combined algorithm provides enhanced detection capability more typical of screening algorithms while maintaining a broad identification capability. Additionally, we will highlight how this approach can enable users to incorporate situational awareness during a response.
Suba, E J; Nguyen, C H; Nguyen, B D; Raab, S S
2001-03-01
Cervical carcinoma is the leading cause of cancer-related death among women in the developing world. The absence of cervical screening in Vietnam and other developing countries is due in large part to the perceived expense of implementing Papanicolaou cytology screening services, although, to the authors' knowledge, the cost-effectiveness of establishing such services has never been studied in a developing country. Using decision analytic methods, the authors assessed cost-effectiveness of Pap screening from a societal perspective in Vietnam, the world's 9th most populous developing country (estimated 1999 population, 79 million). Outcomes measured included life expectancy, cervical carcinoma incidence, cost per woman, and cost-effectiveness. Total costs to establish a nationwide 5-year interval Pap screening program in Vietnam will average less than $148,400 annually during the 10-year time period assumed necessary to develop the program and may be considerably lower if only high risk geographic areas are targeted. Maintenance costs will average less than $0.092 annually per woman in the target screening population. Assuming 70% program participation, cervical carcinoma incidence will decrease from 26 in 100,000 to 14.8 in 100,000, and cost-effectiveness will be $725 per discounted life-year. Several assumptions used in this analysis constitute biases against the effectiveness of Pap screening, which in reality may be significantly more cost-effective than reported here. Contrary to widespread belief, Pap screening in developing countries such as Vietnam is extraordinarily inexpensive and appears to be cost-effective. Because prospects are uncertain regarding useful alternatives to the Pap test, the evidence-based argument for establishing conventional Pap screening services in developing countries such as Vietnam is compelling. Population-based conventional Pap screening services have been established de novo in Vietnam and are now operational. Copyright 2001 American Cancer Society.
Tarifa, Anamary; Almirall, José R
2015-05-01
A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (<2min sampling) and high sensitivity capable of detecting 3ng of diphenylamine (DPA) and 8ng of nitroglycerine (NG). Direct analysis of the headspace of over 50 swabs collected from the hands of suspected shooters (and non-shooters) provides information regarding VOCs present on their hands. In addition, a fast laser induced breakdown spectroscopy (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Shah, Iltaf; Petroczi, Andrea; Uvacsek, Martina; Ránky, Márta; Naughton, Declan P
2014-01-01
Considerable efforts are being extended to develop more effective methods to detect drugs in forensic science for applications such as preventing doping in sport. The aim of this study was to develop a sensitive and accurate method for analytes of forensic and toxicological nature in human hair at sub-pg levels. The hair test covers a range of different classes of drugs and metabolites of forensic and toxicological nature including selected anabolic steroids, cocaine, amphetamines, cannabinoids, opiates, bronchodilators, phencyclidine and ketamine. For extraction purposes, the hair samples were decontaminated using dichloromethane, ground and treated with 1 M sodium hydroxide and neutralised with hydrochloric acid and phosphate buffer and the homogenate was later extracted with hexane using liquid-liquid extraction (LLE). Following extraction from hair samples, drug-screening employed liquid chromatography coupled to tandem mass spectrometric (LC-MS/MS) analysis using dynamic multiple reaction monitoring (DYN-MRM) method using proprietary software. The screening method (for > 200 drugs/metabolites) was calibrated with a tailored drug mixture and was validated for 20 selected drugs for this study. Using standard additions to hair sample extracts, validation was in line with FDA guidance. A Zorbax Eclipse plus C18 (2.1 mm internal diameter × 100 mm length × 1.8 μm particle size) column was used for analysis. Total instrument run time was 8 minutes with no noted matrix interferences. The LOD of compounds ranged between 0.05-0.5 pg/mg of hair. 233 human hair samples were screened using this new method and samples were confirmed positive for 20 different drugs, mainly steroids and drugs of abuse. This is the first report of the application of this proprietary system to investigate the presence of drugs in human hair samples. The method is selective, sensitive and robust for the screening and confirmation of multiple drugs in a single analysis and has potential as a very useful tool for the analysis of large array of controlled substances and drugs of abuse.
Badawi, Nora; Simonsen, Kirsten Wiese; Steentoft, Anni; Bernhoft, Inger Marie; Linnet, Kristian
2009-11-01
The European DRUID (Driving under the Influence of Drugs, Alcohol And Medicines) project calls for analysis of oral fluid (OF) samples, collected randomly and anonymously at the roadside from drivers in Denmark throughout 2008-2009. To analyze these samples we developed an ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for detection of 29 drugs and illicit compounds in OF. The drugs detected were opioids, amphetamines, cocaine, benzodiazepines, and Delta-9-tetrahydrocannabinol. Solid-phase extraction was performed with a Gilson ASPEC XL4 system equipped with Bond Elut Certify sample cartridges. OF samples (200 mg) diluted with 5 mL of ammonium acetate/methanol (vol/vol 90:10) buffer were applied to the columns and eluted with 3 mL of acetonitrile with aqueous ammonium hydroxide. Target drugs were quantified by use of a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole (positive electrospray ionization mode, multiple reaction monitoring mode). Extraction recoveries were 36%-114% for all analytes, including Delta-9-tetrahydrocannabinol and benzoylecgonine. The lower limit of quantification was 0.5 mug/kg for all analytes. Total imprecision (CV) was 5.9%-19.4%. With the use of deuterated internal standards for most compounds, the performance of the method was not influenced by matrix effects. A preliminary account of OF samples collected at the roadside showed the presence of amphetamine, cocaine, codeine, Delta-9-tetrahydrocannabinol, tramadol, and zopiclone. The UPLC-MS/MS method makes it possible to detect all 29 analytes in 1 chromatographic run (15 min), including Delta-9-tetrahydrocannabinol and benzoylecgonine, which previously have been difficult to incorporate into multicomponent methods.
Patel, Prinesh N; Karakam, Vijaya Saradhi; Samanthula, Gananadhamu; Ragampeta, Srinivas
2015-10-01
Quality-by-design-based methods hold greater level of confidence for variations and greater success in method transfer. A quality-by-design-based ultra high performance liquid chromatography method was developed for the simultaneous assay of sumatriptan and naproxen along with their related substances. The first screening was performed by fractional factorial design comprising 44 experiments for reversed-phase stationary phases, pH, and organic modifiers. The results of screening design experiments suggested phenyl hexyl column and acetonitrile were the best combination. The method was further optimized for flow rate, temperature, and gradient time by experimental design of 20 experiments and the knowledge space was generated for effect of variable on response (number of peaks ≥ 1.50 - resolution). Proficient design space was generated from knowledge space by applying Monte Carlo simulation to successfully integrate quantitative robustness metrics during optimization stage itself. The final method provided the robust performance which was verified and validated. Final conditions comprised Waters® Acquity phenyl hexyl column with gradient elution using ammonium acetate (pH 4.12, 0.02 M) buffer and acetonitrile at 0.355 mL/min flow rate and 30°C. The developed method separates all 13 analytes within a 15 min run time with fewer experiments compared to the traditional quality-by-testing approach. ©2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Small compounds libraries: a research tool for chemical biology].
Florent, Jean-Claude
2013-01-01
Obtaining and screening collections of small molecules remain a challenge for biologists. Recent advances in analytical techniques and instrumentation now make screening possible in academia. The history of the creation of such public or commercial collections and their accessibility is related. It shows that there is interest for an academic laboratory involved in medicinal chemistry, chemogenomics or "chemical biology" to organize its own collection and make it available through existing networks such as the French National chimiothèque or the European partner network "European Infrastructure of open screening platforms for Chemical Biology" EU-OpenScreen under construction. © Société de Biologie, 2013.
Cucu, Tatiana; De Meulenaer, Bruno; Devreese, Bart
2012-02-01
Soybean (Glycine max) is extensively used all over the world due to its nutritional qualities. However, soybean is included in the "big eight" list of food allergens. According to the EU directive 2007/68/EC, food products containing soybeans have to be labeled in order to protect the allergic consumers. Nevertheless, soybeans can still inadvertently be present in food products. The development of analytical methods for the detection of traces of allergens is important for the protection of allergic consumers. Mass spectrometry of marker proteolytical fragments of protein allergens is growingly recognized as a detection method in food control. However, quantification of soybean at the peptide level is hindered due to limited information regarding specific stable markers derived after proteolytic digestion. The aim of this study was to use MALDI-TOF/MS and MS/MS as a fast screening tool for the identification of stable soybean derived tryptic markers which were still identifiable even if the proteins were subjected to various changes at the molecular level through a number of reactions typically occurring during food processing (denaturation, the Maillard reaction and oxidation). The peptides (401)Val-Arg(410) from the G1 glycinin (Gly m 6) and the (518)Gln-Arg(528) from the α' chain of the β-conglycinin (Gly m 5) proved to be the most stable. These peptides hold potential to be used as targets for the development of new analytical methods for the detection of soybean protein traces in processed foods. Copyright © 2011 Elsevier Inc. All rights reserved.
Determination of Diethyl Phthalate and Polyhexamethylene Guanidine in Surrogate Alcohol from Russia
Monakhova, Yulia B.; Kuballa, Thomas; Leitz, Jenny; Lachenmeier, Dirk W.
2011-01-01
Analytical methods based on spectroscopic techniques were developed and validated for the determination of diethyl phthalate (DEP) and polyhexamethylene guanidine (PHMG), which may occur in unrecorded alcohol. Analysis for PHMG was based on UV-VIS spectrophotometry after derivatization with Eosin Y and 1H NMR spectroscopy of the DMSO extract. Analysis of DEP was performed with direct UV-VIS and 1H NMR methods. Multivariate curve resolution and spectra computation methods were used to confirm the presence of PHMG and DEP in the investigated beverages. Of 22 analysed alcohol samples, two contained DEP or PHMG. 1H NMR analysis also revealed the presence of signals of hawthorn extract in three medicinal alcohols used as surrogate alcohol. The simple and cheap UV-VIS methods can be used for rapid screening of surrogate alcohol samples for impurities, while 1H NMR is recommended for specific confirmatory analysis if required. PMID:21647285
Determination of diethyl phthalate and polyhexamethylene guanidine in surrogate alcohol from Russia.
Monakhova, Yulia B; Kuballa, Thomas; Leitz, Jenny; Lachenmeier, Dirk W
2011-01-01
Analytical methods based on spectroscopic techniques were developed and validated for the determination of diethyl phthalate (DEP) and polyhexamethylene guanidine (PHMG), which may occur in unrecorded alcohol. Analysis for PHMG was based on UV-VIS spectrophotometry after derivatization with Eosin Y and (1)H NMR spectroscopy of the DMSO extract. Analysis of DEP was performed with direct UV-VIS and (1)H NMR methods. Multivariate curve resolution and spectra computation methods were used to confirm the presence of PHMG and DEP in the investigated beverages. Of 22 analysed alcohol samples, two contained DEP or PHMG. (1)H NMR analysis also revealed the presence of signals of hawthorn extract in three medicinal alcohols used as surrogate alcohol. The simple and cheap UV-VIS methods can be used for rapid screening of surrogate alcohol samples for impurities, while (1)H NMR is recommended for specific confirmatory analysis if required.
Cervical cancer screening in women referred to healthcare centres in Tabriz, Iran.
Farshbaf-Khalili, Azizeh; Salehi-Pourmehr, Hanieh; Shahnazi, Mahnaz; Yaghoubi, Sina; Gahremani-Nasab, Parvaneh
2015-01-01
Cervical cancer is the second most common cancer among Iranian women and among the few cancers that could be easily diagnosed in the pre-malignant stage. We aimed to assess the status of cervical cancer screening in women referred to health care centres in Tabriz, northwest Iran. This descriptive-analytical study was done on 441 women referred to health care centres of Tabriz, northwest Iran. The centres were selected using the multi-stage cluster sampling method. The participants were selected from the active records of those centres. A questionnaire regarding the socio-demographic characteristics and cervical cancer screening and reasons for referring or not referring for screening was completed by the participants A P < 0.05 was considered as significant. Out of the participants 49.4% of women had done the Pap smear test while 50.6% had never done this test. The main reason why women had not performed cervical cancer screening was being unaware of the importance of it (46.1%). Logistic regression analysis with adjustment showed a significant relationship between screening and awareness scores (OR = 1.17, CI = 95%:1.12-1.23), when the effect of other confounding factors [total awareness scores, risk factors (marriage or having sexual intercourse at a young age, history of obvious cervical infection, cautery, cryotherapy or repeated curettage), age and type of family planning] in screening was controlled. Suitable and continuous educational programmes especially for high risk women should be implemented through the health care services. Preparing educational brochures and pamphlets and providing adequate training on the necessity of early referral and marriage counseling could also be effective in improving woman's awareness and performance.
A Generic analytical solution for modelling pumping tests in wells intersecting fractures
NASA Astrophysics Data System (ADS)
Dewandel, Benoît; Lanini, Sandra; Lachassagne, Patrick; Maréchal, Jean-Christophe
2018-04-01
The behaviour of transient flow due to pumping in fractured rocks has been studied for at least the past 80 years. Analytical solutions were proposed for solving the issue of a well intersecting and pumping from one vertical, horizontal or inclined fracture in homogeneous aquifers, but their domain of application-even if covering various fracture geometries-was restricted to isotropic or anisotropic aquifers, whose potential boundaries had to be parallel or orthogonal to the fracture direction. The issue thus remains unsolved for many field cases. For example, a well intersecting and pumping a fracture in a multilayer or a dual-porosity aquifer, where intersected fractures are not necessarily parallel or orthogonal to aquifer boundaries, where several fractures with various orientations intersect the well, or the effect of pumping not only in fractures, but also in the aquifer through the screened interval of the well. Using a mathematical demonstration, we show that integrating the well-known Theis analytical solution (Theis, 1935) along the fracture axis is identical to the equally well-known analytical solution of Gringarten et al. (1974) for a uniform-flux fracture fully penetrating a homogeneous aquifer. This result implies that any existing line- or point-source solution can be used for implementing one or more discrete fractures that are intersected by the well. Several theoretical examples are presented and discussed: a single vertical fracture in a dual-porosity aquifer or in a multi-layer system (with a partially intersecting fracture); one and two inclined fractures in a leaky-aquifer system with pumping either only from the fracture(s), or also from the aquifer between fracture(s) in the screened interval of the well. For the cases with several pumping sources, analytical solutions of flowrate contribution from each individual source (fractures and well) are presented, and the drawdown behaviour according to the length of the pumped screened interval of the well is discussed. Other advantages of this proposed generic analytical solution are also given. The application of this solution to field data should provide additional field information on fracture geometry, as well as identifying the connectivity between the pumped fractures and other aquifers.
Sarangi, Laxmi Narayan; Naveena, Thodangala; Rana, Samir Kumar; Surendra, Kota Sri Naga Leela; Reddy, Rachamreddy Venkata Chandrasekhar; Bajibabu, Putla; Ponnanna, Nadikerianda Muthappa; Sharma, Girish Kumar; Srinivasan, Villuppanoor Alwar
2018-07-01
The extended frozen semen (EFS) batches produced from infectious bovine rhinotracheitis (IBR) sero-positive cattle and buffalo bulls housed in various semen stations in India are transported to the testing laboratory in liquid nitrogen (LN 2 ) for screening bovine herpesvirus-1 (BoHV-1). This procedure is laborious and poses LN 2 related hazards. An alternative logistics for transportation of samples was investigated. Use of Flinders Technology Associates (FTA ® ) elute card was evaluated for transportation of extended bovine semen to screen BoHV-1 DNA by real-time PCR targeting gB gene and the method was compared with the OIE approved Chelex resin based method. A protocol for extraction of BoHV-1 DNA from FTA ® card spotted with extended semen was optimized. The viral DNA was found to be stable on FTA ® card for at least 28 days when the cards are stored at 4°-37 °C. The analytical sensitivity for the assay was determined using variable dilutions of BoHV-1 spiked semen and positive plasmid harbouring gB gene (97bp) spotted onto FTA ® card and it was found to be 10 0.8 TCID 50 /ml or 100 copies respectively in real-time PCR. The test could detect as low as 10 0.008 TCID 50 /ml or 1 copy of positive plasmid when more number of replicates (n = 6) of the same sample were tested. This sensitivity was found to be comparable to Chelex method and both the methods demonstrated a very strong correlation (r = 0.9774; 95% CI: 0.9620-0.9860) in terms of Ct value (p < 0.0001). The diagnostic sensitivity and specificity of the FTA method in comparison to the Chelex method was 83.08% (95% CI: 71.73%-91.24%) and 93.23% (95% CI: 89.38%-96.01%) respectively when 316 samples were screened by both the methods. The degree of agreement between these two tests was good (Kappa value: 0.738; 95% CI: 0.646-0.829). The method was found to be robust and highly repeatable in inter-assay and intra-assay precision testing. The result suggests that the FTA ® card holds promise as an alternative system for transportation of EFS for downstream screening of BoHV-1 DNA. Copyright © 2018 Elsevier B.V. All rights reserved.
Detection of protein-protein interactions by ribosome display and protein in situ immobilisation.
He, Mingyue; Liu, Hong; Turner, Martin; Taussig, Michael J
2009-12-31
We describe a method for identification of protein-protein interactions by combining two cell-free protein technologies, namely ribosome display and protein in situ immobilisation. The method requires only PCR fragments as the starting material, the target proteins being made through cell-free protein synthesis, either associated with their encoding mRNA as ribosome complexes or immobilised on a solid surface. The use of ribosome complexes allows identification of interacting protein partners from their attached coding mRNA. To demonstrate the procedures, we have employed the lymphocyte signalling proteins Vav1 and Grb2 and confirmed the interaction between Grb2 and the N-terminal SH3 domain of Vav1. The method has promise for library screening of pairwise protein interactions, down to the analytical level of individual domain or motif mapping.
Bakas, Idriss; Hayat, Akhtar; Piletsky, Sergey; Piletska, Elena; Chehimi, Mohamed M; Noguer, Thierry; Rouillon, Régis
2014-12-01
We report here a novel method to detect methidathion organophosphorous insecticides. The sensing platform was architected by the combination of molecularly imprinted polymers and sol-gel technique on inexpensive, portable and disposable screen printed carbon electrodes. Electrochemical impedimetric detection technique was employed to perform the label free detection of the target analyte on the designed MIP/sol-gel integrated platform. The selection of the target specific monomer by electrochemical impedimetric methods was consistent with the results obtained by the computational modelling method. The prepared electrochemical MIP/sol-gel based sensor exhibited a high recognition capability toward methidathion, as well as a broad linear range and a low detection limit under the optimized conditions. Satisfactory results were also obtained for the methidathion determination in waste water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Schroyer, B.R.; Capel, P.D.
1996-01-01
A high-performance liquid Chromatography (HPLC) method is presented for the for the fast, quantitative analysis of the target analytes in water and in low organic-carbon, sandy soils that are known to be contaminated with the parent herbicides. Speed and ease of sample preparation was prioritized above minimizing detection limits. Soil samples were extracted using 80:20 methanol:water (volume:volume). Water samples (50 ??L) were injected directly into the HPLC without prior preparation. Method quantification limits for soil samples (10 g dry weight) and water samples ranged from 20 to 110 ng/g and from 20 to 110 ??g/L for atrazine and its transformation products and from 80 to 320 ng/g and from 80 to 320 ??g/L for alachlor and its transformation products, respectively.
Poljak, Mario; Ostrbenk, Anja; Seme, Katja; Ucakar, Veronika; Hillemanns, Peter; Bokal, Eda Vrtacnik; Jancar, Nina; Klavs, Irena
2011-05-01
The clinical performance of the Abbott RealTime High Risk HPV (human papillomavirus) test (RealTime) and that of the Hybrid Capture 2 HPV DNA test (hc2) were prospectively compared in the population-based cervical cancer screening setting. In women >30 years old (n = 3,129), the clinical sensitivity of RealTime for detection of cervical intraepithelial neoplasia of grade 2 (CIN2) or worse (38 cases) and its clinical specificity for lesions of less than CIN2 (3,091 controls) were 100% and 93.3%, respectively, and those of hc2 were 97.4% and 91.8%, respectively. A noninferiority score test showed that the clinical specificity (P < 0.0001) and clinical sensitivity (P = 0.011) of RealTime were noninferior to those of hc2 at the recommended thresholds of 98% and 90%. In the total study population (women 20 to 64 years old; n = 4,432; 57 cases, 4,375 controls), the clinical sensitivity and specificity of RealTime were 98.2% and 89.5%, and those of hc2 were 94.7% and 87.7%, respectively. The analytical sensitivity and analytical specificity of RealTime in detecting targeted HPV types evaluated with the largest sample collection to date (4,479 samples) were 94.8% and 99.8%, and those of hc2 were 93.4% and 97.8%, respectively. Excellent analytical agreement between the two assays was obtained (kappa value, 0.84), while the analytical accuracy of RealTime was significantly higher than that of hc2. RealTime demonstrated high intralaboratory reproducibility and interlaboratory agreement with 500 samples retested 61 to 226 days after initial testing in two different laboratories. RealTime can be considered to be a reliable and robust HPV assay clinically comparable to hc2 for the detection of CIN2+ lesions in a population-based cervical cancer screening setting.
Rockers, Peter C.; Bonawitz, Rachael; Sriruttan, Charlotte; Glencross, Deborah K.; Cassim, Naseem; Coetzee, Lindi M.; Greene, Gregory S.; Chiller, Tom M.; Vallabhaneni, Snigdha; Long, Lawrence; van Rensburg, Craig; Govender, Nelesh P.
2016-01-01
Background In 2015 South Africa established a national cryptococcal antigenemia (CrAg) screening policy targeted at HIV-infected patients with CD4+ T-lymphocyte (CD4) counts <100 cells/ μl who are not yet on antiretroviral treatment (ART). Two screening strategies are included in national guidelines: reflex screening, where a CrAg test is performed on remnant blood samples from CD4 testing; and provider-initiated screening, where providers order a CrAg test after a patient returns for CD4 test results. The objective of this study was to compare costs and effectiveness of these two screening strategies. Methods We developed a decision analytic model to compare reflex and provider-initiated screening in terms of programmatic and health outcomes (number screened, number identified for preemptive treatment, lives saved, and discounted years of life saved) and screening and treatment costs (2015 USD). We estimated a base case with prevalence and other parameters based on data collected during CrAg screening pilot projects integrated into routine HIV care in Gauteng, Free State, and Western Cape Provinces. We conducted sensitivity analyses to explore how results change with underlying parameter assumptions. Results In the base case, for each 100,000 CD4 tests, the reflex strategy compared to the provider-initiated strategy has higher screening costs ($37,536 higher) but lower treatment costs ($55,165 lower), so overall costs of screening and treatment are $17,629 less with the reflex strategy. The reflex strategy saves more lives (30 lives, 647 additional years of life saved). Sensitivity analyses suggest that reflex screening dominates provider-initiated screening (lower total costs and more lives saved) or saves additional lives for small additional costs (< $125 per life year) across a wide range of conditions (CrAg prevalence, patient and provider behavior, patient survival without treatment, and effectiveness of preemptive fluconazole treatment). Conclusions In countries with substantial numbers of people with untreated, advanced HIV disease such as South Africa, CrAg screening before initiation of ART has the potential to reduce cryptococcal meningitis and save lives. Reflex screening compared to provider-initiated screening saves more lives and is likely to be cost saving or have low additional costs per additional year of life saved. PMID:27390864
Rojas, D; Jurado-Sánchez, B; Escarpa, A
2016-04-05
A novel Janus micromotor-based strategy for the direct determination of diphenyl phthalate (DPP) in food and biological samples is presented. Mg/Au Janus micromotors are employed as novel analytical platforms for the degradation of the non-electroactive DPP into phenol, which is directly measured by difference pulse voltammetry on disposable screen-printed electrodes. The self-movement of the micromotors along the samples result in the generation of hydrogen microbubbles and hydroxyl ions for DPP degradation. The increased fluid transport improves dramatically the analytical signal, increasing the sensitivity while lowering the detection potential. The method has been successfully applied to the direct analysis of DPP in selected food and biological samples, without any sample treatment and avoiding any potential contamination from laboratory equipment. The developed approach is fast (∼5 min) and accurate with recoveries of ∼100%. In addition, efficient propulsion of multiple Mg/Au micromotors in complex samples has also been demonstrated. The advantages of the micromotors-assisted technology, i.e., disposability, portability, and the possibility to carry out multiple analysis simultaneously, hold considerable promise for its application in food and biological control in analytical applications with high significance.
Guo, Baoshan; Lei, Cheng; Kobayashi, Hirofumi; Ito, Takuro; Yalikun, Yaxiaer; Jiang, Yiyue; Tanaka, Yo; Ozeki, Yasuyuki; Goda, Keisuke
2017-05-01
The development of reliable, sustainable, and economical sources of alternative fuels to petroleum is required to tackle the global energy crisis. One such alternative is microalgal biofuel, which is expected to play a key role in reducing the detrimental effects of global warming as microalgae absorb atmospheric CO 2 via photosynthesis. Unfortunately, conventional analytical methods only provide population-averaged lipid amounts and fail to characterize a diverse population of microalgal cells with single-cell resolution in a non-invasive and interference-free manner. Here high-throughput label-free single-cell screening of lipid-producing microalgal cells with optofluidic time-stretch quantitative phase microscopy was demonstrated. In particular, Euglena gracilis, an attractive microalgal species that produces wax esters (suitable for biodiesel and aviation fuel after refinement), within lipid droplets was investigated. The optofluidic time-stretch quantitative phase microscope is based on an integration of a hydrodynamic-focusing microfluidic chip, an optical time-stretch quantitative phase microscope, and a digital image processor equipped with machine learning. As a result, it provides both the opacity and phase maps of every single cell at a high throughput of 10,000 cells/s, enabling accurate cell classification without the need for fluorescent staining. Specifically, the dataset was used to characterize heterogeneous populations of E. gracilis cells under two different culture conditions (nitrogen-sufficient and nitrogen-deficient) and achieve the cell classification with an error rate of only 2.15%. The method holds promise as an effective analytical tool for microalgae-based biofuel production. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
Ibrahim, Omer Mohammed Ali; Bilal, Naser Eldin; Osman, Omran Fadl; Magzoub, Magzoub Abbas
2017-01-01
The heterogeneous expression of methicillin resistance in Staphylococcus aureus (MRSA) affects the efficiency of tests available to detect it. The objective of this study was to assess four phenotypic tests used to detect MRSA. This is an analytical comparative study conducted among sudanese patients during period from May 2012 to July 2014, Staphylococcus aureus strains were isolated and identified by conventional methods, and then confirmed by PCR detection of coagulase gene. PCR detection of mecA gene was used as a gold standard to assess oxacillin resistance screen agar base (ORSAB), oxacillin disc, cefoxitin disc (at different temperatures and incubation periods) and MRSA-latex agglutination test. S.aureus ATCC 25923 was used as control. Sensitivity and specificity were calculated. MRSA- latex agglutination was the most accurate test; it showed 100% of both sensitivity and specificity, followed by cefoxitin disc with sensitivity of 98.48% and specificity of 100%. However, both of oxacillin disc and oxacillin resistance screen agar base showed less accurate results, and were affected by incubation periods. Oxacillin disc after 24 h incubation both at 30°C and 35°C showed sensitivity and specificity values of 87.88% and 96.23%, respectively. However, after 48h incubation the test at 30°C showed sensitivity and specificity values of 89.39%, and 94.34%, respectively. At 35°C (48h) it showed values of 89.39%, 92.45% respectively. Specificity of ORSAB was more than oxacillin disc at 35°C after 24h incubation 98.11% and 96.23%, respectively. MRSA- latex agglutination and cefoxitin disc diffusion tests are recommended for routine detection of MRSA.
Mitchell, J M; Griffiths, M W; McEwen, S A; McNab, W B; Yee, A J
1998-06-01
This paper presents a historical review of antimicrobial use in food animals, the causes of residues in meat and milk, the types of residues found, their regulation in Canada, tests used for their detection, and test performance parameters, with an emphasis on immunoassay techniques. The development of residue detection methods began shortly after the introduction of antimicrobials to food animal production in the late 1940s. From initial technical concerns expressed by the dairy industry to the present public health and international trade implications, there has been an ongoing need for reliable, sensitive, and economical methods for the detection of antimicrobial residues in food animal products such as milk and meat. Initially there were microbial growth inhibition tests, followed by more sensitive and specific methods based on receptor binding, immunochemical, and chromatographic principle. An understanding of basic test performance parameters and their implications is essential when choosing an analytical strategy for residue testing. While each test format has its own attributes, none test will meet all the required analytical needs. Therefore the use of a tiered or integrated system employing assays designated for screening and confirmation is necessary to ensure that foods containing violative residues are not introduced into the food chain.
Guo, Xiangyu; Bai, Hua; Lv, Yueguang; Xi, Guangcheng; Li, Junfang; Ma, Xiaoxiao; Ren, Yue; Ouyang, Zheng; Ma, Qiang
2018-04-01
Rapid, on-site analysis was achieved through significantly simplified operation procedures for a wide variety of toy samples (crayon, temporary tattoo sticker, finger paint, modeling clay, and bubble solution) using a miniature mass spectrometry system with ambient ionization capability. The labor-intensive analytical protocols involving sample workup and chemical separation, traditionally required for MS-based analysis, were replaced by direct sampling analysis using ambient ionization methods. A Mini β ion trap miniature mass spectrometer was coupled with versatile ambient ionization methods, e.g. paper spray, extraction spray and slug-flow microextraction nanoESI for direct identification of prohibited colorants, carcinogenic primary aromatic amines, allergenic fragrances, preservatives and plasticizers from raw toy samples. The use of paper substrates coated with Co 3 O 4 nanoparticles allowed a great increase in sensitivity for paper spray. Limits of detection as low as 5μgkg -1 were obtained for target analytes. The methods being developed based on the integration of ambient ionization with miniature mass spectrometer represent alternatives to current in-lab MS analysis operation, and would enable fast, outside-the-lab screening of toy products to ensure children's safety and health. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zou, Wenli; Filatov, Michael; Cremer, Dieter
2015-06-01
The analytical gradient for the two-component Normalized Elimination of the Small Component (2c-NESC) method is presented. The 2c-NESC is a Dirac-exact method that employs the exact two-component one-electron Hamiltonian and thus leads to exact Dirac spin-orbit (SO) splittings for one-electron atoms. For many-electron atoms and molecules, the effect of the two-electron SO interaction is modeled by a screened nucleus potential using effective nuclear charges as proposed by Boettger [Phys. Rev. B 62, 7809 (2000)]. The effect of spin-orbit coupling (SOC) on molecular geometries is analyzed utilizing the properties of the frontier orbitals and calculated SO couplings. It is shown that bond lengths can either be lengthened or shortened under the impact of SOC where in the first case the influence of low lying excited states with occupied antibonding orbitals plays a role and in the second case the jj-coupling between occupied antibonding and unoccupied bonding orbitals dominates. In general, the effect of SOC on bond lengths is relatively small (≤5% of the scalar relativistic changes in the bond length). However, large effects are found for van der Waals complexes Hg2 and Cn2, which are due to the admixture of more bonding character to the highest occupied spinors.
Protein Multiplexed Immunoassay Analysis with R.
Breen, Edmond J
2017-01-01
Plasma samples from 177 control and type 2 diabetes patients collected at three Australian hospitals are screened for 14 analytes using six custom-made multiplex kits across 60 96-well plates. In total 354 samples were collected from the patients, representing one baseline and one end point sample from each patient. R methods and source code for analyzing the analyte fluorescence response obtained from these samples by Luminex Bio-Plex ® xMap multiplexed immunoassay technology are disclosed. Techniques and R procedures for reading Bio-Plex ® result files for statistical analysis and data visualization are also presented. The need for technical replicates and the number of technical replicates are addressed as well as plate layout design strategies. Multinomial regression is used to determine plate to sample covariate balance. Methods for matching clinical covariate information to Bio-Plex ® results and vice versa are given. As well as methods for measuring and inspecting the quality of the fluorescence responses are presented. Both fixed and mixed-effect approaches for immunoassay statistical differential analysis are presented and discussed. A random effect approach to outlier analysis and detection is also shown. The bioinformatics R methodology present here provides a foundation for rigorous and reproducible analysis of the fluorescence response obtained from multiplexed immunoassays.