Kumar, B Vinodh; Mohan, Thuthi
2018-01-01
Six Sigma is one of the most popular quality management system tools employed for process improvement. The Six Sigma methods are usually applied when the outcome of the process can be measured. This study was done to assess the performance of individual biochemical parameters on a Sigma Scale by calculating the sigma metrics for individual parameters and to follow the Westgard guidelines for appropriate Westgard rules and levels of internal quality control (IQC) that needs to be processed to improve target analyte performance based on the sigma metrics. This is a retrospective study, and data required for the study were extracted between July 2015 and June 2016 from a Secondary Care Government Hospital, Chennai. The data obtained for the study are IQC - coefficient of variation percentage and External Quality Assurance Scheme (EQAS) - Bias% for 16 biochemical parameters. For the level 1 IQC, four analytes (alkaline phosphatase, magnesium, triglyceride, and high-density lipoprotein-cholesterol) showed an ideal performance of ≥6 sigma level, five analytes (urea, total bilirubin, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level and for level 2 IQCs, same four analytes of level 1 showed a performance of ≥6 sigma level, and four analytes (urea, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level. For all analytes <6 sigma level, the quality goal index (QGI) was <0.8 indicating the area requiring improvement to be imprecision except cholesterol whose QGI >1.2 indicated inaccuracy. This study shows that sigma metrics is a good quality tool to assess the analytical performance of a clinical chemistry laboratory. Thus, sigma metric analysis provides a benchmark for the laboratory to design a protocol for IQC, address poor assay performance, and assess the efficiency of existing laboratory processes.
Critical behavior of a relativistic Bose gas.
Pandita, P N
2014-03-01
We show that the thermodynamic behavior of relativistic ideal Bose gas, recently studied numerically by Grether et al., can be obtained analytically. Using the analytical results, we obtain the critical behavior of the relativistic Bose gas exactly for all the regimes. We show that these analytical results reduce to those of Grether et al. in different regimes of the Bose gas. Furthermore, we also obtain an analytically closed-form expression for the energy density for the Bose gas that is valid in all regimes.
Reproducibility studies for experimental epitope detection in macrophages (EDIM).
Japink, Dennis; Nap, Marius; Sosef, Meindert N; Nelemans, Patty J; Coy, Johannes F; Beets, Geerard; von Meyenfeldt, Maarten F; Leers, Math P G
2014-05-01
We have recently described epitope detection in macrophages (EDIM) by flow cytometry. This is a promising tool for the diagnosis and follow-up of malignancies. However, biological and technical validation is warranted before clinical applicability can be explored. The pre-analytic and analytic phases were investigated. Five different aspects were assessed: blood sample stability, intra-individual variability in healthy persons, intra-assay variation, inter-assay variation and assay transferability. The post-analytic phase was already partly standardized and described in an earlier study. The outcomes in the pre-analytic phase showed that samples are stable for 24h after venipuncture. Biological variation over time was similar to that of serum tumor marker assays; each patient has a baseline value. Intra-assay variation showed good reproducibility, while inter-assay variation showed reproducibility similar to that of to established serum tumor marker assays. Furthermore, the assay showed excellent transferability between analyzers. Under optimal analytic conditions the EDIM method is technically stable, reproducible and transferable. Biological variation over time needs further assessment in future work. Copyright © 2014 Elsevier B.V. All rights reserved.
Kumar, B. Vinodh; Mohan, Thuthi
2018-01-01
OBJECTIVE: Six Sigma is one of the most popular quality management system tools employed for process improvement. The Six Sigma methods are usually applied when the outcome of the process can be measured. This study was done to assess the performance of individual biochemical parameters on a Sigma Scale by calculating the sigma metrics for individual parameters and to follow the Westgard guidelines for appropriate Westgard rules and levels of internal quality control (IQC) that needs to be processed to improve target analyte performance based on the sigma metrics. MATERIALS AND METHODS: This is a retrospective study, and data required for the study were extracted between July 2015 and June 2016 from a Secondary Care Government Hospital, Chennai. The data obtained for the study are IQC - coefficient of variation percentage and External Quality Assurance Scheme (EQAS) - Bias% for 16 biochemical parameters. RESULTS: For the level 1 IQC, four analytes (alkaline phosphatase, magnesium, triglyceride, and high-density lipoprotein-cholesterol) showed an ideal performance of ≥6 sigma level, five analytes (urea, total bilirubin, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level and for level 2 IQCs, same four analytes of level 1 showed a performance of ≥6 sigma level, and four analytes (urea, albumin, cholesterol, and potassium) showed an average performance of <3 sigma level. For all analytes <6 sigma level, the quality goal index (QGI) was <0.8 indicating the area requiring improvement to be imprecision except cholesterol whose QGI >1.2 indicated inaccuracy. CONCLUSION: This study shows that sigma metrics is a good quality tool to assess the analytical performance of a clinical chemistry laboratory. Thus, sigma metric analysis provides a benchmark for the laboratory to design a protocol for IQC, address poor assay performance, and assess the efficiency of existing laboratory processes. PMID:29692587
Remane, Daniela; Wissenbach, Dirk K; Meyer, Markus R; Maurer, Hans H
2010-04-15
In clinical and forensic toxicology, multi-analyte procedures are very useful to quantify drugs and poisons of different classes in one run. For liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multi-analyte procedures, often only a limited number of stable-isotope-labeled internal standards (SIL-ISs) are available. If an SIL-IS is used for quantification of other analytes, it must be excluded that the co-eluting native analyte influences its ionization. Therefore, the effect of ion suppression and enhancement of fourteen SIL-ISs caused by their native analogues has been studied. It could be shown that the native analyte concentration influenced the extent of ion suppression and enhancement effects leading to more suppression with increasing analyte concentration especially when electrospray ionization (ESI) was used. Using atmospheric-pressure chemical ionization (APCI), methanolic solution showed mainly enhancement effects, whereas no ion suppression and enhancement effect, with one exception, occurred when plasma extracts were used under these conditions. Such differences were not observed using ESI. With ESI, eleven SIL-ISs showed relevant suppression effects, but only one analyte showed suppression effects when APCI was used. The presented study showed that ion suppression and enhancement tests using matrix-based samples of different sources are essential for the selection of ISs, particularly if used for several analytes to avoid incorrect quantification. In conclusion, only SIL-ISs should be selected for which no suppression and enhancement effects can be observed. If not enough ISs are free of ionization interferences, a different ionization technique should be considered. 2010 John Wiley & Sons, Ltd.
Kangas, Michael J; Burks, Raychelle M; Atwater, Jordyn; Lukowicz, Rachel M; Garver, Billy; Holmes, Andrea E
2018-02-01
With the increasing availability of digital imaging devices, colorimetric sensor arrays are rapidly becoming a simple, yet effective tool for the identification and quantification of various analytes. Colorimetric arrays utilize colorimetric data from many colorimetric sensors, with the multidimensional nature of the resulting data necessitating the use of chemometric analysis. Herein, an 8 sensor colorimetric array was used to analyze select acid and basic samples (0.5 - 10 M) to determine which chemometric methods are best suited for classification quantification of analytes within clusters. PCA, HCA, and LDA were used to visualize the data set. All three methods showed well-separated clusters for each of the acid or base analytes and moderate separation between analyte concentrations, indicating that the sensor array can be used to identify and quantify samples. Furthermore, PCA could be used to determine which sensors showed the most effective analyte identification. LDA, KNN, and HQI were used for identification of analyte and concentration. HQI and KNN could be used to correctly identify the analytes in all cases, while LDA correctly identified 95 of 96 analytes correctly. Additional studies demonstrated that controlling for solvent and image effects was unnecessary for all chemometric methods utilized in this study.
ERIC Educational Resources Information Center
Shindler, John; Taylor, Clint; Cadenas, Herminia; Jones, Albert
This study was a pilot effort to examine the efficacy of an analytic trait scale school climate assessment instrument and democratic change system in two urban high schools. Pilot study results indicate that the instrument shows promising soundness in that it exhibited high levels of validity and reliability. In addition, the analytic trait format…
Heuristic and analytic processing in online sports betting.
d'Astous, Alain; Di Gaspero, Marc
2015-06-01
This article presents the results of two studies that examine the occurrence of heuristic (i.e., intuitive and fast) and analytic (i.e., deliberate and slow) processes among people who engage in online sports betting on a regular basis. The first study was qualitative and was conducted with a convenience sample of 12 regular online sports gamblers who described the processes by which they arrive at a sports betting decision. The results of this study showed that betting online on sports events involves a mix of heuristic and analytic processes. The second study consisted in a survey of 161 online sports gamblers where performance in terms of monetary gains, experience in online sports betting, propensity to collect and analyze relevant information prior to betting, and use of bookmaker odds were measured. This study showed that heuristic and analytic processes act as mediators of the relationship between experience and performance. The findings stemming of these two studies give some insights into gamblers' modes of thinking and behaviors in an online sports betting context and show the value of the dual mediation process model for research that looks at gambling activities from a judgment and decision making perspective.
Pitting intuitive and analytical thinking against each other: the case of transitivity.
Rusou, Zohar; Zakay, Dan; Usher, Marius
2013-06-01
Identifying which thinking mode, intuitive or analytical, yields better decisions has been a major subject of inquiry by decision-making researchers. Yet studies show contradictory results. One possibility is that the ambiguity is due to the variability in experimental conditions across studies. Our hypothesis is that decision quality depends critically on the level of compatibility between the thinking mode employed in the decision and the nature of the decision-making task. In two experiments, we pitted intuition and analytical thinking against each other on tasks that were either mainly intuitive or mainly analytical. Thinking modes, as well as task characteristics, were manipulated in a factorial design, with choice transitivity as the dependent measure. Results showed higher choice consistency (transitivity) when thinking mode and the characteristics of the decision task were compatible.
Comparative Kinetic Analysis of Closed-Ended and Open-Ended Porous Sensors
NASA Astrophysics Data System (ADS)
Zhao, Yiliang; Gaur, Girija; Mernaugh, Raymond L.; Laibinis, Paul E.; Weiss, Sharon M.
2016-09-01
Efficient mass transport through porous networks is essential for achieving rapid response times in sensing applications utilizing porous materials. In this work, we show that open-ended porous membranes can overcome diffusion challenges experienced by closed-ended porous materials in a microfluidic environment. A theoretical model including both transport and reaction kinetics is employed to study the influence of flow velocity, bulk analyte concentration, analyte diffusivity, and adsorption rate on the performance of open-ended and closed-ended porous sensors integrated with flow cells. The analysis shows that open-ended pores enable analyte flow through the pores and greatly reduce the response time and analyte consumption for detecting large molecules with slow diffusivities compared with closed-ended pores for which analytes largely flow over the pores. Experimental confirmation of the results was carried out with open- and closed-ended porous silicon (PSi) microcavities fabricated in flow-through and flow-over sensor configurations, respectively. The adsorption behavior of small analytes onto the inner surfaces of closed-ended and open-ended PSi membrane microcavities was similar. However, for large analytes, PSi membranes in a flow-through scheme showed significant improvement in response times due to more efficient convective transport of analytes. The experimental results and theoretical analysis provide quantitative estimates of the benefits offered by open-ended porous membranes for different analyte systems.
NASA Astrophysics Data System (ADS)
Nurhasanah, F.; Kusumah, Y. S.; Sabandar, J.; Suryadi, D.
2018-05-01
As one of the non-conventional mathematics concepts, Parallel Coordinates is potential to be learned by pre-service mathematics teachers in order to give them experiences in constructing richer schemes and doing abstraction process. Unfortunately, the study related to this issue is still limited. This study wants to answer a research question “to what extent the abstraction process of pre-service mathematics teachers in learning concept of Parallel Coordinates could indicate their performance in learning Analytic Geometry”. This is a case study that part of a larger study in examining mathematical abstraction of pre-service mathematics teachers in learning non-conventional mathematics concept. Descriptive statistics method is used in this study to analyze the scores from three different tests: Cartesian Coordinate, Parallel Coordinates, and Analytic Geometry. The participants in this study consist of 45 pre-service mathematics teachers. The result shows that there is a linear association between the score on Cartesian Coordinate and Parallel Coordinates. There also found that the higher levels of the abstraction process in learning Parallel Coordinates are linearly associated with higher student achievement in Analytic Geometry. The result of this study shows that the concept of Parallel Coordinates has a significant role for pre-service mathematics teachers in learning Analytic Geometry.
A European multicenter study on the analytical performance of the VERIS HBV assay.
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Maria Angeles; Sauné, Karine; O Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel
Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. Precision showed an SD of 0.15 log 10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log 10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Is a pre-analytical process for urinalysis required?
Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole
2017-10-01
For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.
Kimura, Y; Yu, D G; Kinoshita, J; Hossain, M; Yokoyama, K; Murakami, Y; Nomura, K; Takamura, R; Matsumoto, K
2001-04-01
The purpose of this study was to investigate the morphological and atomic changes on the root surface by stereoscopy, field emission-scanning electron microscopy (FE-SEM), and energy dispersive X-ray spectroscopy (SEM-EDX) after erbium, chromium:yttrium, scandium, gallium, garnet (Er,Cr:YSGG) laser irradiation in vitro. There have been few reports on morphological and atomic analytical study on root surface by Er,Cr:YSGG laser irradiation. Eighteen extracted human premolar and molar teeth were irradiated on root surfaces at a vertical position with water-air spray by an Er,Cr:YSGG laser at the parameter of 5.0 W and 20 Hz for 5 sec while moving. The samples were then morphologically observed by stereoscopy and FE-SEM and examined atomic-analytically by SEM-EDX. Craters having rough but clean surfaces and no melting or carbonization were observed in the samples. An atomic analytical examination showed that the calcium ratio to phosphorus showed no significant changes between the control and irradiated areas (p > 0.01). These results showed that the Er,Cr:YSGG laser has a good cutting effect on root surface and causes no burning or melting after laser irradiation.
Multi-center evaluation of analytical performance of the Beckman Coulter AU5822 chemistry analyzer.
Zimmerman, M K; Friesen, L R; Nice, A; Vollmer, P A; Dockery, E A; Rankin, J D; Zmuda, K; Wong, S H
2015-09-01
Our three academic institutions, Indiana University, Northwestern Memorial Hospital, and Wake Forest, were among the first in the United States to implement the Beckman Coulter AU5822 series chemistry analyzers. We undertook this post-hoc multi-center study by merging our data to determine performance characteristics and the impact of methodology changes on analyte measurement. We independently completed performance validation studies including precision, linearity/analytical measurement range, method comparison, and reference range verification. Complete data sets were available from at least one institution for 66 analytes with the following groups: 51 from all three institutions, and 15 from 1 or 2 institutions for a total sample size of 12,064. Precision was similar among institutions. Coefficients of variation (CV) were <10% for 97%. Analytes with CVs >10% included direct bilirubin and digoxin. All analytes exhibited linearity over the analytical measurement range. Method comparison data showed slopes between 0.900-1.100 for 87.9% of the analytes. Slopes for amylase, tobramycin and urine amylase were <0.8; the slope for lipase was >1.5, due to known methodology or standardization differences. Consequently, reference ranges of amylase, urine amylase and lipase required only minor or no modification. The four AU5822 analyzers independently evaluated at three sites showed consistent precision, linearity, and correlation results. Since installations, the test results had been well received by clinicians from all three institutions. Copyright © 2015. Published by Elsevier Inc.
Ryan, Patrick B.; Schuemie, Martijn
2013-01-01
Background: Clinical studies that use observational databases, such as administrative claims and electronic health records, to evaluate the effects of medical products have become commonplace. These studies begin by selecting a particular study design, such as a case control, cohort, or self-controlled design, and different authors can and do choose different designs for the same clinical question. Furthermore, published papers invariably report the study design but do not discuss the rationale for the specific choice. Studies of the same clinical question with different designs, however, can generate different results, sometimes with strikingly different implications. Even within a specific study design, authors make many different analytic choices and these too can profoundly impact results. In this paper, we systematically study heterogeneity due to the type of study design and due to analytic choices within study design. Methods and findings: We conducted our analysis in 10 observational healthcare databases but mostly present our results in the context of the GE Centricity EMR database, an electronic health record database containing data for 11.2 million lives. We considered the impact of three different study design choices on estimates of associations between bisphosphonates and four particular health outcomes for which there is no evidence of an association. We show that applying alternative study designs can yield discrepant results, in terms of direction and significance of association. We also highlight that while traditional univariate sensitivity analysis may not show substantial variation, systematic assessment of all analytical choices within a study design can yield inconsistent results ranging from statistically significant decreased risk to statistically significant increased risk. Our findings show that clinical studies using observational databases can be sensitive both to study design choices and to specific analytic choices within study design. Conclusion: More attention is needed to consider how design choices may be impacting results and, when possible, investigators should examine a wide array of possible choices to confirm that significant findings are consistently identified. PMID:25083251
Applying an analytical method to study neutron behavior for dosimetry
NASA Astrophysics Data System (ADS)
Shirazi, S. A. Mousavi
2016-12-01
In this investigation, a new dosimetry process is studied by applying an analytical method. This novel process is associated with a human liver tissue. The human liver tissue has compositions including water, glycogen and etc. In this study, organic compound materials of liver are decomposed into their constituent elements based upon mass percentage and density of every element. The absorbed doses are computed by analytical method in all constituent elements of liver tissue. This analytical method is introduced applying mathematical equations based on neutron behavior and neutron collision rules. The results show that the absorbed doses are converged for neutron energy below 15MeV. This method can be applied to study the interaction of neutrons in other tissues and estimating the absorbed dose for a wide range of neutron energy.
Liberals think more analytically (more "WEIRD") than conservatives.
Talhelm, Thomas; Haidt, Jonathan; Oishi, Shigehiro; Zhang, Xuemin; Miao, Felicity F; Chen, Shimin
2015-02-01
Henrich, Heine, and Norenzayan summarized cultural differences in psychology and argued that people from one particular culture are outliers: people from societies that are Western, educated, industrialized, rich, and democratic (WEIRD). This study shows that liberals think WEIRDer than conservatives. In five studies with more than 5,000 participants, we found that liberals think more analytically (an element of WEIRD thought) than moderates and conservatives. Study 3 replicates this finding in the very different political culture of China, although it held only for people in more modernized urban centers. These results suggest that liberals and conservatives in the same country think as if they were from different cultures. Studies 4 to 5 show that briefly training people to think analytically causes them to form more liberal opinions, whereas training them to think holistically causes shifts to more conservative opinions. © 2014 by the Society for Personality and Social Psychology, Inc.
Gozzi, Marta; Cherubini, Paolo; Papagno, Costanza; Bricolo, Emanuela
2011-05-01
Previous studies found mixed results concerning the role of working memory (WM) in the gambling task (GT). Here, we aimed at reconciling inconsistencies by showing that the standard version of the task can be solved using intuitive strategies operating automatically, while more complex versions require analytic strategies drawing on executive functions. In Study 1, where good performance on the GT could be achieved using intuitive strategies, participants performed well both with and without a concurrent WM load. In Study 2, where analytical strategies were required to solve a more complex version of the GT, participants without WM load performed well, while participants with WM load performed poorly. In Study 3, where the complexity of the GT was further increased, participants in both conditions performed poorly. In addition to the standard performance measure, we used participants' subjective expected utility, showing that it differs from the standard measure in some important aspects.
Bias Assessment of General Chemistry Analytes using Commutable Samples.
Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter
2014-11-01
Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.
NASA Technical Reports Server (NTRS)
Esker, Barbara S.; Debonis, James R.
1991-01-01
Flow through a combined ventral and axial exhaust nozzle system was studied experimentally and analytically. The work is part of an ongoing propulsion technology effort at NASA Lewis Research Center for short takeoff, vertical landing (STOVL) aircraft. The experimental investigation was done on the NASA Lewis Powered Lift Facility. The experiment consisted of performance testing over a range of tailpipe pressure ratios from 1 to 3.2 and flow visualization. The analytical investigation consisted of modeling the same configuration and solving for the flow using the PARC3D computational fluid dynamics program. The comparison of experimental and analytical results was very good. The ventral nozzle performance coefficients obtained from both the experimental and analytical studies agreed within 1.2 percent. The net horizontal thrust of the nozzle system contained a significant reverse thrust component created by the flow overturning in the ventral duct. This component resulted in a low net horizontal thrust coefficient. The experimental and analytical studies showed very good agreement in the internal flow patterns.
Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results.
Pasqualetti, Sara; Braga, Federica; Panteghini, Mauro
2017-07-01
The measurement of plasma glucose (PG) plays a central role in recognizing disturbances in carbohydrate metabolism, with established decision limits that are globally accepted. This requires that PG results are reliable and unequivocally valid no matter where they are obtained. To control the pre-analytical variability of PG and prevent in vitro glycolysis, the use of citrate as rapidly effective glycolysis inhibitor has been proposed. However, the commercial availability of several tubes with studies showing different performance has created confusion among users. Moreover, and more importantly, studies have shown that tubes promptly inhibiting glycolysis give PG results that are significantly higher than tubes containing sodium fluoride only, used in the majority of studies generating the current PG cut-points, with a different clinical classification of subjects. From the analytical point of view, to be equivalent among different measuring systems, PG results should be traceable to a recognized higher-order reference via the implementation of an unbroken metrological hierarchy. In doing this, it is important that manufacturers of measuring systems consider the uncertainty accumulated through the different steps of the selected traceability chain. In particular, PG results should fulfil analytical performance specifications defined to fit the intended clinical application. Since PG has tight homeostatic control, its biological variability may be used to define these limits. Alternatively, given the central diagnostic role of the analyte, an outcome model showing the impact of analytical performance of test on clinical classifications of subjects can be used. Using these specifications, performance assessment studies employing commutable control materials with values assigned by reference procedure have shown that the quality of PG measurements is often far from desirable and that problems are exacerbated using point-of-care devices. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
One-dimensional backreacting holographic superconductors with exponential nonlinear electrodynamics
NASA Astrophysics Data System (ADS)
Ghotbabadi, B. Binaei; Zangeneh, M. Kord; Sheykhi, A.
2018-05-01
In this paper, we investigate the effects of nonlinear exponential electrodynamics as well as backreaction on the properties of one-dimensional s-wave holographic superconductors. We continue our study both analytically and numerically. In analytical study, we employ the Sturm-Liouville method while in numerical approach we perform the shooting method. We obtain a relation between the critical temperature and chemical potential analytically. Our results show a good agreement between analytical and numerical methods. We observe that the increase in the strength of both nonlinearity and backreaction parameters causes the formation of condensation in the black hole background harder and critical temperature lower. These results are consistent with those obtained for two dimensional s-wave holographic superconductors.
Charge transport and trapping in organic field effect transistors exposed to polar analytes
NASA Astrophysics Data System (ADS)
Duarte, Davianne; Sharma, Deepak; Cobb, Brian; Dodabalapur, Ananth
2011-03-01
Pentacene based organic thin-film transistors were used to study the effects of polar analytes on charge transport and trapping behavior during vapor sensing. Three sets of devices with differing morphology and mobility (0.001-0.5 cm2/V s) were employed. All devices show enhanced trapping upon exposure to analyte molecules. The organic field effect transistors with different mobilities also provide evidence for morphology dependent partition coefficients. This study helps provide a physical basis for many reports on organic transistor based sensor response.
NASA Technical Reports Server (NTRS)
Prust, H. W., Jr.
1971-01-01
The results of an analytical study to determine the effect of changes in the amount, velocity, injection location, injection angle, and temperature of coolant flow on blade row performance are presented. The results show that the change in output of a cooled turbine blade row relative to the specific output of the uncooled blade row can be positive, negative, or zero. Comparisons between the analytical results and experimental results for four different cases of coolant discharge, all at a coolant temperature ratio of unity, show good agreement for three cases and rather poor agreement for the other. To further test the validity of the method, more experimental data is needed, particularly at different coolant temperature ratios.
A new frequency approach for light flicker evaluation in electric power systems
NASA Astrophysics Data System (ADS)
Feola, Luigi; Langella, Roberto; Testa, Alfredo
2015-12-01
In this paper, a new analytical estimator for light flicker in frequency domain, which is able to take into account also the frequency components neglected by the classical methods proposed in literature, is proposed. The analytical solutions proposed apply for any generic stationary signal affected by interharmonic distortion. The light flicker analytical estimator proposed is applied to numerous numerical case studies with the goal of showing i) the correctness and the improvements of the analytical approach proposed with respect to the other methods proposed in literature and ii) the accuracy of the results compared to those obtained by means of the classical International Electrotechnical Commission (IEC) flickermeter. The usefulness of the proposed analytical approach is that it can be included in signal processing tools for interharmonic penetration studies for the integration of renewable energy sources in future smart grids.
NASA Astrophysics Data System (ADS)
Ravi, J. T.; Nidhan, S.; Muthu, N.; Maiti, S. K.
2018-02-01
An analytical method for determination of dimensions of longitudinal crack in monolithic beams, based on frequency measurements, has been extended to model L and inverted T cracks. Such cracks including longitudinal crack arise in beams made of layered isotropic or composite materials. A new formulation for modelling cracks in bi-material beams is presented. Longitudinal crack segment sizes, for L and inverted T cracks, varying from 2.7% to 13.6% of length of Euler-Bernoulli beams are considered. Both forward and inverse problems have been examined. In the forward problems, the analytical results are compared with finite element (FE) solutions. In the inverse problems, the accuracy of prediction of crack dimensions is verified using FE results as input for virtual testing. The analytical results show good agreement with the actual crack dimensions. Further, experimental studies have been done to verify the accuracy of the analytical method for prediction of dimensions of three types of crack in isotropic and bi-material beams. The results show that the proposed formulation is reliable and can be employed for crack detection in slender beam like structures in practice.
Language and Verbal Short-Term Memory Skills in Children with Down Syndrome: A Meta-Analytic Review
ERIC Educational Resources Information Center
Naess, Kari-Anne B.; Lyster, Solveig-Alma Halaas; Hulme, Charles; Melby-Lervag, Monica
2011-01-01
This study presents a meta-analytic review of language and verbal short-term memory skills in children with Down syndrome. The study examines the profile of strengths and weaknesses in children with Down syndrome compared to typically developing children matched for nonverbal mental age. The findings show that children with Down syndrome have…
NASA Astrophysics Data System (ADS)
Chen, J. S.; Chiang, S. Y.; Liang, C. P.
2017-12-01
It is essential to develop multispecies transport analytical models based on a set of advection-dispersion equations (ADEs) coupled with sequential first-order decay reactions for the synchronous prediction of plume migrations of both parent and its daughter species of decaying contaminants such as radionuclides, dissolved chlorinated organic compounds, pesticides and nitrogen. Although several analytical models for multispecies transport have already been reported, those currently available in the literature have primarily been derived based on ADEs with constant dispersion coefficients. However, there have been a number of studies demonstrating that the dispersion coefficients increase with the solute travel distance as a consequence of variation in the hydraulic properties of the porous media. This study presents novel analytical models for multispecies transport with distance-dependent dispersion coefficients. The correctness of the derived analytical models is confirmed by comparing them against the numerical models. Results show perfect agreement between the analytical and numerical models. Comparison of our new analytical model for multispecies transport with scale-dependent dispersion to an analytical model with constant dispersion is made to illustrate the effects of the dispersion coefficients on the multispecies transport of decaying contaminants.
Validating Analytical Protocols to Determine Selected Pesticides and PCBs Using Routine Samples.
Pindado Jiménez, Oscar; García Alonso, Susana; Pérez Pastor, Rosa María
2017-01-01
This study aims at providing recommendations concerning the validation of analytical protocols by using routine samples. It is intended to provide a case-study on how to validate the analytical methods in different environmental matrices. In order to analyze the selected compounds (pesticides and polychlorinated biphenyls) in two different environmental matrices, the current work has performed and validated two analytical procedures by GC-MS. A description is given of the validation of the two protocols by the analysis of more than 30 samples of water and sediments collected along nine months. The present work also scopes the uncertainty associated with both analytical protocols. In detail, uncertainty of water sample was performed through a conventional approach. However, for the sediments matrices, the estimation of proportional/constant bias is also included due to its inhomogeneity. Results for the sediment matrix are reliable, showing a range 25-35% of analytical variability associated with intermediate conditions. The analytical methodology for the water matrix determines the selected compounds with acceptable recoveries and the combined uncertainty ranges between 20 and 30%. Analyzing routine samples is rarely applied to assess trueness of novel analytical methods and up to now this methodology was not focused on organochlorine compounds in environmental matrices.
Shim, Jaesool; Yoo, Kisoo; Dutta, Prashanta
2017-03-01
The determination of an analytical solution to find the steady-state protein concentration distribution in IEF is very challenging due to the nonlinear coupling between mass and charge conservation equations. In this study, approximate analytical solutions are obtained for steady-state protein distribution in carrier ampholyte based IEF. Similar to the work of Svensson, the final concentration profile for proteins is assumed to be Gaussian, but appropriate expressions are presented in order to obtain the effective electric field and pH gradient in the focused protein band region. Analytical results are found from iterative solutions of a system of coupled algebraic equations using only several iterations for IEF separation of three plasma proteins: albumin, cardiac troponin I, and hemoglobin. The analytical results are compared with numerically predicted results for IEF, showing excellent agreement. Analytically obtained electric field and ionic conductivity distributions show significant deviation from their nominal values, which is essential in finding the protein focusing behavior at isoelectric points. These analytical solutions can be used to determine steady-state protein concentration distribution for experiment design of IEF considering any number of proteins and ampholytes. Moreover, the model presented herein can be used to find the conductivity, electric field, and pH field. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ellipsoidal Brownian self-driven particles in a magnetic field
NASA Astrophysics Data System (ADS)
Fan, Wai-Tong Louis; Pak, On Shun; Sandoval, Mario
2017-03-01
We study the two-dimensional Brownian dynamics of an ellipsoidal paramagnetic microswimmer moving at a low Reynolds number and subject to a magnetic field. Its corresponding mean-square displacement, showing the effect of a particles's shape, activity, and magnetic field on the microswimmer's diffusion, is analytically obtained. Comparison between analytical and computational results shows good agreement. In addition, the effect of self-propulsion on the transition time from anisotropic to isotropic diffusion of the ellipse is investigated.
Malys, Brian J; Owens, Kevin G
2017-05-15
Matrix-assisted laser desorption/ionization (MALDI) is widely used as the ionization method in high-resolution chemical imaging studies that seek to visualize the distribution of analytes within sectioned biological tissues. This work extends the use of electrospray deposition (ESD) to apply matrix with an additional solvent spray to incorporate and homogenize analyte within the matrix overlayer. Analytes and matrix are sequentially and independently applied by ESD to create a sample from which spectra are collected, mimicking a MALDI imaging mass spectrometry (IMS) experiment. Subsequently, an incorporation spray consisting of methanol is applied by ESD to the sample and another set of spectra are collected. The spectra prior to and after the incorporation spray are compared to evaluate the improvement in the analyte signal. Prior to the incorporation spray, samples prepared using α-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as the matrix showed low signal while the sample using sinapinic acid (SA) initially exhibited good signal. Following the incorporation spray, the sample using SA did not show an increase in signal; the sample using DHB showed moderate gain factors of 2-5 (full ablation spectra) and 12-336 (raster spectra), while CHCA samples saw large increases in signal, with gain factors of 14-172 (full ablation spectra) and 148-1139 (raster spectra). The use of an incorporation spray to apply solvent by ESD to a matrix layer already deposited by ESD provides an increase in signal by both promoting incorporation of the analyte within and homogenizing the distribution of the incorporated analyte throughout the matrix layer. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Kanoglu, U.; Wronna, M.; Baptista, M. A.; Miranda, J. M. A.
2017-12-01
The one-dimensional analytical runup theory in combination with near shore synthetic waveforms is a promising tool for tsunami rapid early warning systems. Its application in realistic cases with complex bathymetry and initial wave condition from inverse modelling have shown that maximum runup values can be estimated reasonably well. In this study we generate a simplistic bathymetry domains which resemble realistic near-shore features. We investigate the accuracy of the analytical runup formulae to the variation of fault source parameters and near-shore bathymetric features. To do this we systematically vary the fault plane parameters to compute the initial tsunami wave condition. Subsequently, we use the initial conditions to run the numerical tsunami model using coupled system of four nested grids and compare the results to the analytical estimates. Variation of the dip angle of the fault plane showed that analytical estimates have less than 10% difference for angles 5-45 degrees in a simple bathymetric domain. These results shows that the use of analytical formulae for fast run up estimates constitutes a very promising approach in a simple bathymetric domain and might be implemented in Hazard Mapping and Early Warning.
Child Negative Emotionality and Parenting from Infancy to Preschool: A Meta-Analytic Review
ERIC Educational Resources Information Center
Paulussen-Hoogeboom, Marja C.; Stams, Geert Jan J. M.; Hermanns, Jo M. A.; Peetsma, Thea T. D.
2007-01-01
This meta-analytic review (k = 62 studies; N = 7,613 mother-child dyads) shows that effect sizes for the association between child negative emotionality and parenting were generally small and were moderated by sample and measurement characteristics. The association between more child negative emotionality and less supportive parenting was…
Analytic thinking reduces belief in conspiracy theories.
Swami, Viren; Voracek, Martin; Stieger, Stefan; Tran, Ulrich S; Furnham, Adrian
2014-12-01
Belief in conspiracy theories has been associated with a range of negative health, civic, and social outcomes, requiring reliable methods of reducing such belief. Thinking dispositions have been highlighted as one possible factor associated with belief in conspiracy theories, but actual relationships have only been infrequently studied. In Study 1, we examined associations between belief in conspiracy theories and a range of measures of thinking dispositions in a British sample (N=990). Results indicated that a stronger belief in conspiracy theories was significantly associated with lower analytic thinking and open-mindedness and greater intuitive thinking. In Studies 2-4, we examined the causational role played by analytic thinking in relation to conspiracist ideation. In Study 2 (N=112), we showed that a verbal fluency task that elicited analytic thinking reduced belief in conspiracy theories. In Study 3 (N=189), we found that an alternative method of eliciting analytic thinking, which related to cognitive disfluency, was effective at reducing conspiracist ideation in a student sample. In Study 4, we replicated the results of Study 3 among a general population sample (N=140) in relation to generic conspiracist ideation and belief in conspiracy theories about the July 7, 2005, bombings in London. Our results highlight the potential utility of supporting attempts to promote analytic thinking as a means of countering the widespread acceptance of conspiracy theories. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sukji, Paweena; Wichaidit, Pacharee Rompayom; Wichaidit, Sittichai
2018-01-01
The objectives of this study were to: 1) compare learning achievement and analytical thinking ability of Mathayomsuksa 3 students before and after learning through inquiry-based learning activities integrated with the local learning resource, and 2) compare average post-test score of learning achievement and analytical thinking ability to its cutting score. The target of this study was 23 Mathayomsuksa 3 students who were studying in the second semester of 2016 academic year from Banchatfang School, Chainat Province. Research instruments composed of: 1) 6 lesson plans of Environment and Natural Resources, 2) the learning achievement test, and 3) analytical thinking ability test. The results showed that 1) student' learning achievement and analytical thinking ability after learning were higher than that of before at the level of .05 statistical significance, and 2) average posttest score of student' learning achievement and analytical thinking ability were higher than its cutting score at the level of .05 statistical significance. The implication of this research is for science teachers and curriculum developers to design inquiry activities that relate to student's context.
ERIC Educational Resources Information Center
Capraro, Mary Margaret; Capraro, Robert M.
2003-01-01
Studied the reporting preferences of editorial board members of four scholarly journals in education and psychology with regard to analytic practices in the fifth edition of the American Psychological Association "Publication Manual." Responses of 106 board members show the movement toward reform in research reporting practices. (SLD)
NASA Astrophysics Data System (ADS)
Mirel, Barbara; Kumar, Anuj; Nong, Paige; Su, Gang; Meng, Fan
2016-02-01
Life scientists increasingly use visual analytics to explore large data sets and generate hypotheses. Undergraduate biology majors should be learning these same methods. Yet visual analytics is one of the most underdeveloped areas of undergraduate biology education. This study sought to determine the feasibility of undergraduate biology majors conducting exploratory analysis using the same interactive data visualizations as practicing scientists. We examined 22 upper level undergraduates in a genomics course as they engaged in a case-based inquiry with an interactive heat map. We qualitatively and quantitatively analyzed students' visual analytic behaviors, reasoning and outcomes to identify student performance patterns, commonly shared efficiencies and task completion. We analyzed students' successes and difficulties in applying knowledge and skills relevant to the visual analytics case and related gaps in knowledge and skill to associated tool designs. Findings show that undergraduate engagement in visual analytics is feasible and could be further strengthened through tool usability improvements. We identify these improvements. We speculate, as well, on instructional considerations that our findings suggested may also enhance visual analytics in case-based modules.
Kumar, Anuj; Nong, Paige; Su, Gang; Meng, Fan
2016-01-01
Life scientists increasingly use visual analytics to explore large data sets and generate hypotheses. Undergraduate biology majors should be learning these same methods. Yet visual analytics is one of the most underdeveloped areas of undergraduate biology education. This study sought to determine the feasibility of undergraduate biology majors conducting exploratory analysis using the same interactive data visualizations as practicing scientists. We examined 22 upper level undergraduates in a genomics course as they engaged in a case-based inquiry with an interactive heat map. We qualitatively and quantitatively analyzed students’ visual analytic behaviors, reasoning and outcomes to identify student performance patterns, commonly shared efficiencies and task completion. We analyzed students’ successes and difficulties in applying knowledge and skills relevant to the visual analytics case and related gaps in knowledge and skill to associated tool designs. Findings show that undergraduate engagement in visual analytics is feasible and could be further strengthened through tool usability improvements. We identify these improvements. We speculate, as well, on instructional considerations that our findings suggested may also enhance visual analytics in case-based modules. PMID:26877625
Jędrkiewicz, Renata; Orłowski, Aleksander; Namieśnik, Jacek; Tobiszewski, Marek
2016-01-15
In this study we perform ranking of analytical procedures for 3-monochloropropane-1,2-diol determination in soy sauces by PROMETHEE method. Multicriteria decision analysis was performed for three different scenarios - metrological, economic and environmental, by application of different weights to decision making criteria. All three scenarios indicate capillary electrophoresis-based procedure as the most preferable. Apart from that the details of ranking results differ for these three scenarios. The second run of rankings was done for scenarios that include metrological, economic and environmental criteria only, neglecting others. These results show that green analytical chemistry-based selection correlates with economic, while there is no correlation with metrological ones. This is an implication that green analytical chemistry can be brought into laboratories without analytical performance costs and it is even supported by economic reasons. Copyright © 2015 Elsevier B.V. All rights reserved.
Analytical methods for dating modern writing instrument inks on paper.
Ezcurra, Magdalena; Góngora, Juan M G; Maguregui, Itxaso; Alonso, Rosa
2010-04-15
This work reviews the different analytical methods that have been proposed in the field of forensic dating of inks from different modern writing instruments. The reported works have been classified according to the writing instrument studied and the ink component analyzed in relation to aging. The study, done chronologically, shows the advances experienced in the ink dating field in the last decades. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Nielsen, Marie Katrine Klose; Johansen, Sys Stybe; Linnet, Kristian
2014-01-01
Assessment of total uncertainty of analytical methods for the measurements of drugs in human hair has mainly been derived from the analytical variation. However, in hair analysis several other sources of uncertainty will contribute to the total uncertainty. Particularly, in segmental hair analysis pre-analytical variations associated with the sampling and segmentation may be significant factors in the assessment of the total uncertainty budget. The aim of this study was to develop and validate a method for the analysis of 31 common drugs in hair using ultra-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with focus on the assessment of both the analytical and pre-analytical sampling variations. The validated method was specific, accurate (80-120%), and precise (CV≤20%) across a wide linear concentration range from 0.025-25 ng/mg for most compounds. The analytical variation was estimated to be less than 15% for almost all compounds. The method was successfully applied to 25 segmented hair specimens from deceased drug addicts showing a broad pattern of poly-drug use. The pre-analytical sampling variation was estimated from the genuine duplicate measurements of two bundles of hair collected from each subject after subtraction of the analytical component. For the most frequently detected analytes, the pre-analytical variation was estimated to be 26-69%. Thus, the pre-analytical variation was 3-7 folds larger than the analytical variation (7-13%) and hence the dominant component in the total variation (29-70%). The present study demonstrated the importance of including the pre-analytical variation in the assessment of the total uncertainty budget and in the setting of the 95%-uncertainty interval (±2CVT). Excluding the pre-analytical sampling variation could significantly affect the interpretation of results from segmental hair analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Assessing the effect of cognitive styles with different learning modes on learning outcome.
Liao, Chechen; Chuang, Shu-Hui
2007-08-01
In this study, similarities and differences in learning outcome associated with individual differences in cognitive styles are examined using the traditional (face-to-face) and web-based learning modes. 140 undergraduate students were categorized as having analytic or holistic cognitive styles by their scores on the Style of Learning and Thinking questionnaire. Four different conditions were studies; students with analytic cognitive style in a traditional learning mode, analytic cognitive style in a web-based learning mode, holistic cognitive style in a traditional learning mode, and holistic cognitive style in a web-based learning mode. Analysis of the data show that analytic style in traditional mode lead to significantly higher performance and perceived satisfaction than in other conditions. Satisfaction did not differ significantly between students with analytic style in web-based learning and those with holistic style in traditional learning. This suggest that integrating different learning modes into the learning environment may be insufficient to improve learners' satisfaction.
Analytic information processing style in epilepsy patients.
Buonfiglio, Marzia; Di Sabato, Francesco; Mandillo, Silvia; Albini, Mariarita; Di Bonaventura, Carlo; Giallonardo, Annateresa; Avanzini, Giuliano
2017-08-01
Relevant to the study of epileptogenesis is learning processing, given the pivotal role that neuroplasticity assumes in both mechanisms. Recently, evoked potential analyses showed a link between analytic cognitive style and altered neural excitability in both migraine and healthy subjects, regardless of cognitive impairment or psychological disorders. In this study we evaluated analytic/global and visual/auditory perceptual dimensions of cognitive style in patients with epilepsy. Twenty-five cryptogenic temporal lobe epilepsy (TLE) patients matched with 25 idiopathic generalized epilepsy (IGE) sufferers and 25 healthy volunteers were recruited and participated in three cognitive style tests: "Sternberg-Wagner Self-Assessment Inventory", the C. Cornoldi test series called AMOS, and the Mariani Learning style Questionnaire. Our results demonstrate a significant association between analytic cognitive style and both IGE and TLE and respectively a predominant auditory and visual analytic style (ANOVA: p values <0,0001). These findings should encourage further research to investigate information processing style and its neurophysiological correlates in epilepsy. Copyright © 2017 Elsevier Inc. All rights reserved.
The Development of Proofs in Analytical Mathematics for Undergraduate Students
NASA Astrophysics Data System (ADS)
Ali, Maselan; Sufahani, Suliadi; Hasim, Nurnazifa; Saifullah Rusiman, Mohd; Roslan, Rozaini; Mohamad, Mahathir; Khalid, Kamil
2018-04-01
Proofs in analytical mathematics are essential parts of mathematics, difficult to learn because its underlying concepts are not visible. This research consists of problems involving logic and proofs. In this study, a short overview was provided on how proofs in analytical mathematics were used by university students. From the results obtained, excellent students obtained better scores compared to average and poor students. The research instruments used in this study consisted of two parts: test and interview. In this way, analysis of students’ actual performances can be obtained. The result of this study showed that the less able students have fragile conceptual and cognitive linkages but the more able students use their strong conceptual linkages to produce effective solutions
Numerical applications of the advective-diffusive codes for the inner magnetosphere
NASA Astrophysics Data System (ADS)
Aseev, N. A.; Shprits, Y. Y.; Drozdov, A. Y.; Kellerman, A. C.
2016-11-01
In this study we present analytical solutions for convection and diffusion equations. We gather here the analytical solutions for the one-dimensional convection equation, the two-dimensional convection problem, and the one- and two-dimensional diffusion equations. Using obtained analytical solutions, we test the four-dimensional Versatile Electron Radiation Belt code (the VERB-4D code), which solves the modified Fokker-Planck equation with additional convection terms. The ninth-order upwind numerical scheme for the one-dimensional convection equation shows much more accurate results than the results obtained with the third-order scheme. The universal limiter eliminates unphysical oscillations generated by high-order linear upwind schemes. Decrease in the space step leads to convergence of a numerical solution of the two-dimensional diffusion equation with mixed terms to the analytical solution. We compare the results of the third- and ninth-order schemes applied to magnetospheric convection modeling. The results show significant differences in electron fluxes near geostationary orbit when different numerical schemes are used.
ERIC Educational Resources Information Center
Miron-Spektor, Ella; Efrat-Treister, Dorit; Rafaeli, Anat; Schwarz-Cohen, Orit
2011-01-01
The authors examine whether and how observing anger influences thinking processes and problem-solving ability. In 3 studies, the authors show that participants who listened to an angry customer were more successful in solving analytic problems, but less successful in solving creative problems compared with participants who listened to an…
New analytical solutions to the two-phase water faucet problem
Zou, Ling; Zhao, Haihua; Zhang, Hongbin
2016-06-17
Here, the one-dimensional water faucet problem is one of the classical benchmark problems originally proposed by Ransom to study the two-fluid two-phase flow model. With certain simplifications, such as massless gas phase and no wall and interfacial frictions, analytical solutions had been previously obtained for the transient liquid velocity and void fraction distribution. The water faucet problem and its analytical solutions have been widely used for the purposes of code assessment, benchmark and numerical verifications. In our previous study, the Ransom’s solutions were used for the mesh convergence study of a high-resolution spatial discretization scheme. It was found that, atmore » the steady state, an anticipated second-order spatial accuracy could not be achieved, when compared to the existing Ransom’s analytical solutions. A further investigation showed that the existing analytical solutions do not actually satisfy the commonly used two-fluid single-pressure two-phase flow equations. In this work, we present a new set of analytical solutions of the water faucet problem at the steady state, considering the gas phase density’s effect on pressure distribution. This new set of analytical solutions are used for mesh convergence studies, from which anticipated second-order of accuracy is achieved for the 2nd order spatial discretization scheme. In addition, extended Ransom’s transient solutions for the gas phase velocity and pressure are derived, with the assumption of decoupled liquid and gas pressures. Numerical verifications on the extended Ransom’s solutions are also presented.« less
Analytical modeling and numerical simulation of the short-wave infrared electron-injection detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Movassaghi, Yashar; Fathipour, Morteza; Fathipour, Vala
2016-03-21
This paper describes comprehensive analytical and simulation models for the design and optimization of the electron-injection based detectors. The electron-injection detectors evaluated here operate in the short-wave infrared range and utilize a type-II band alignment in InP/GaAsSb/InGaAs material system. The unique geometry of detectors along with an inherent negative-feedback mechanism in the device allows for achieving high internal avalanche-free amplifications without any excess noise. Physics-based closed-form analytical models are derived for the detector rise time and dark current. Our optical gain model takes into account the drop in the optical gain at high optical power levels. Furthermore, numerical simulation studiesmore » of the electrical characteristics of the device show good agreement with our analytical models as well experimental data. Performance comparison between devices with different injector sizes shows that enhancement in the gain and speed is anticipated by reducing the injector size. Sensitivity analysis for the key detector parameters shows the relative importance of each parameter. The results of this study may provide useful information and guidelines for development of future electron-injection based detectors as well as other heterojunction photodetectors.« less
FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING REMOTE ...
FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL LABORATORY, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-008-105065. ALTERNATE ID NUMBER 4272-14-102. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Initialization and Simulation of Three-Dimensional Aircraft Wake Vortices
NASA Technical Reports Server (NTRS)
Ash, Robert L.; Zheng, Z. C.
1997-01-01
This paper studies the effects of axial velocity profiles on vortex decay, in order to properly initialize and simulate three-dimensional wake vortex flow. Analytical relationships are obtained based on a single vortex model and computational simulations are performed for a rather practical vortex wake, which show that the single vortex analytical relations can still be applicable at certain streamwise sections of three-dimensional wake vortices.
An analytical study of double bend achromat lattice.
Fakhri, Ali Akbar; Kant, Pradeep; Singh, Gurnam; Ghodke, A D
2015-03-01
In a double bend achromat, Chasman-Green (CG) lattice represents the basic structure for low emittance synchrotron radiation sources. In the basic structure of CG lattice single focussing quadrupole (QF) magnet is used to form an achromat. In this paper, this CG lattice is discussed and an analytical relation is presented, showing the limitation of basic CG lattice to provide the theoretical minimum beam emittance in achromatic condition. To satisfy theoretical minimum beam emittance parameters, achromat having two, three, and four quadrupole structures is presented. In this structure, different arrangements of QF and defocusing quadruple (QD) are used. An analytical approach assuming quadrupoles as thin lenses has been followed for studying these structures. A study of Indus-2 lattice in which QF-QD-QF configuration in the achromat part has been adopted is also presented.
Maximum of a Fractional Brownian Motion: Analytic Results from Perturbation Theory.
Delorme, Mathieu; Wiese, Kay Jörg
2015-11-20
Fractional Brownian motion is a non-Markovian Gaussian process X_{t}, indexed by the Hurst exponent H. It generalizes standard Brownian motion (corresponding to H=1/2). We study the probability distribution of the maximum m of the process and the time t_{max} at which the maximum is reached. They are encoded in a path integral, which we evaluate perturbatively around a Brownian, setting H=1/2+ϵ. This allows us to derive analytic results beyond the scaling exponents. Extensive numerical simulations for different values of H test these analytical predictions and show excellent agreement, even for large ϵ.
Flexural waves induced by electro-impulse deicing forces
NASA Technical Reports Server (NTRS)
Gien, P. H.
1990-01-01
The generation, reflection and propagation of flexural waves created by electroimpulsive deicing forces are demonstrated both experimentally and analytically in a thin circular plate and a thin semicylindrical shell. Analytical prediction of these waves with finite element models shows good correlation with acceleration and displacement measurements at discrete points on the structures studied. However, sensitivity to spurious flexural waves resulting from the spatial discretization of the structures is shown to be significant. Consideration is also given to composite structures as an extension of these studies.
Møller, Mette F; Søndergaard, Tove R; Kristensen, Helle T; Münster, Anna-Marie B
2017-09-01
Background Centrifugation of blood samples is an essential preanalytical step in the clinical biochemistry laboratory. Centrifugation settings are often altered to optimize sample flow and turnaround time. Few studies have addressed the effect of altering centrifugation settings on analytical quality, and almost all studies have been done using collection tubes with gel separator. Methods In this study, we compared a centrifugation time of 5 min at 3000 × g to a standard protocol of 10 min at 2200 × g. Nine selected general chemistry and immunochemistry analytes and interference indices were studied in lithium heparin plasma tubes and serum tubes without gel separator. Results were evaluated using mean bias, difference plots and coefficient of variation, compared with maximum allowable bias and coefficient of variation used in laboratory routine quality control. Results For all analytes except lactate dehydrogenase, the results were within the predefined acceptance criteria, indicating that the analytical quality was not compromised. Lactate dehydrogenase showed higher values after centrifugation for 5 min at 3000 × g, mean bias was 6.3 ± 2.2% and the coefficient of variation was 5%. Conclusions We found that a centrifugation protocol of 5 min at 3000 × g can be used for the general chemistry and immunochemistry analytes studied, with the possible exception of lactate dehydrogenase, which requires further assessment.
Guided-inquiry laboratory experiments to improve students' analytical thinking skills
NASA Astrophysics Data System (ADS)
Wahyuni, Tutik S.; Analita, Rizki N.
2017-12-01
This study aims to improve the experiment implementation quality and analytical thinking skills of undergraduate students through guided-inquiry laboratory experiments. This study was a classroom action research conducted in three cycles. The study has been carried out with 38 undergraduate students of the second semester of Biology Education Department of State Islamic Institute (SII) of Tulungagung, as a part of Chemistry for Biology course. The research instruments were lesson plans, learning observation sheets and undergraduate students' experimental procedure. Research data were analyzed using quantitative-descriptive method. The increasing of analytical thinking skills could be measured using gain score normalized and statistical paired t-test. The results showed that guided-inquiry laboratory experiments model was able to improve both the experiment implementation quality and the analytical thinking skills. N-gain score of the analytical thinking skills was increased, in spite of just 0.03 with low increase category, indicated by experimental reports. Some of undergraduate students have had the difficulties in detecting the relation of one part to another and to an overall structure. The findings suggested that giving feedback the procedural knowledge and experimental reports were important. Revising the experimental procedure that completed by some scaffolding questions were also needed.
Technical pre-analytical effects on the clinical biochemistry of Atlantic salmon (Salmo salar L.).
Braceland, M; Houston, K; Ashby, A; Matthews, C; Haining, H; Rodger, H; Eckersall, P D
2017-01-01
Clinical biochemistry has long been utilized in human and veterinary medicine as a vital diagnostic tool, but despite occasional studies showing its usefulness in monitoring health status in Atlantic salmon (Salmo salar L.), it has not yet been widely utilized within the aquaculture industry. This is due, in part, to a lack of an agreed protocol for collection and processing of blood prior to analysis. Moreover, while the analytical phase of clinical biochemistry is well controlled, there is a growing understanding that technical pre-analytical variables can influence analyte concentrations or activities. In addition, post-analytical interpretation of treatment effects is variable in the literature, thus making the true effect of sample treatment hard to evaluate. Therefore, a number of pre-analytical treatments have been investigated to examine their effect on analyte concentrations and activities. In addition, reference ranges for salmon plasma biochemical analytes have been established to inform veterinary practitioners and the aquaculture industry of the importance of clinical biochemistry in health and disease monitoring. Furthermore, a standardized protocol for blood collection has been proposed. © 2016 The Authors Journal of Fish Diseases Published by John Wiley & Sons Ltd.
Kim, Dalho; Han, Jungho; Choi, Yongwook
2013-01-01
A method using on-line solid-phase microextraction (SPME) on a carbowax-templated fiber followed by liquid chromatography (LC) with ultraviolet (UV) detection was developed for the determination of triclosan in environmental water samples. Along with triclosan, other selected phenolic compounds, bisphenol A, and acidic pharmaceuticals were studied. Previous SPME/LC or stir-bar sorptive extraction/LC-UV for polar analytes showed lack of sensitivity. In this study, the calculated octanol-water distribution coefficient (log D) values of the target analytes at different pH values were used to estimate polarity of the analytes. The lack of sensitivity observed in earlier studies is identified as a lack of desorption by strong polar-polar interactions between analyte and solid-phase. Calculated log D values were useful to understand or predict the interaction between analyte and solid phase. Under the optimized conditions, the method detection limit of selected analytes by using on-line SPME-LC-UV method ranged from 5 to 33 ng L(-1), except for very polar 3-chlorophenol and 2,4-dichlorophenol which was obscured in wastewater samples by an interfering substance. This level of detection represented a remarkable improvement over the conventional existing methods. The on-line SPME-LC-UV method, which did not require derivatization of analytes, was applied to the determination of TCS including phenolic compounds and acidic pharmaceuticals in tap water and river water and municipal wastewater samples.
Pravdin, Sergey F; Dierckx, Hans; Katsnelson, Leonid B; Solovyova, Olga; Markhasin, Vladimir S; Panfilov, Alexander V
2014-01-01
We develop a numerical approach based on our recent analytical model of fiber structure in the left ventricle of the human heart. A special curvilinear coordinate system is proposed to analytically include realistic ventricular shape and myofiber directions. With this anatomical model, electrophysiological simulations can be performed on a rectangular coordinate grid. We apply our method to study the effect of fiber rotation and electrical anisotropy of cardiac tissue (i.e., the ratio of the conductivity coefficients along and across the myocardial fibers) on wave propagation using the ten Tusscher-Panfilov (2006) ionic model for human ventricular cells. We show that fiber rotation increases the speed of cardiac activation and attenuates the effects of anisotropy. Our results show that the fiber rotation in the heart is an important factor underlying cardiac excitation. We also study scroll wave dynamics in our model and show the drift of a scroll wave filament whose velocity depends non-monotonically on the fiber rotation angle; the period of scroll wave rotation decreases with an increase of the fiber rotation angle; an increase in anisotropy may cause the breakup of a scroll wave, similar to the mother rotor mechanism of ventricular fibrillation.
Study and development of acoustic treatment for jet engine tailpipes
NASA Technical Reports Server (NTRS)
Nelson, M. D.; Linscheid, L. L.; Dinwiddie, B. A., III; Hall, O. J., Jr.
1971-01-01
A study and development program was accomplished to attenuate turbine noise generated in the JT3D turbofan engine. Analytical studies were used to design an acoustic liner for the tailpipe. Engine ground tests defined the tailpipe environmental factors and laboratory tests were used to support the analytical studies. Furnace-brazed, stainless steel, perforated sheet acoustic liners were designed, fabricated, installed, and ground tested in the tailpipe of a JT3D engine. Test results showed the turbine tones were suppressed below the level of the jet exhaust for most far field polar angles.
Experimental and analytical studies of high heat flux components for fusion experimental reactor
NASA Astrophysics Data System (ADS)
Araki, Masanori
1993-03-01
In this report, the experimental and analytical results concerning the development of plasma facing components of ITER are described. With respect to developing high heat removal structures for the divertor plates, an externally-finned swirl tube was developed based on the results of critical heat flux (CHF) experiments on various tube structures. As the result, the burnout heat flux, which also indicates incident CHF, of 41 (+/-) 1 MW/sq m was achieved in the externally-finned swirl tube. The applicability of existing CHF correlations based on uniform heating conditions was evaluated by comparing the CHF experimental data with the smooth and the externally-finned tubes under one-sided heating condition. As the results, experimentally determined CHF data for straight tube show good agreement, for the externally-finned tube, no existing correlations are available for prediction of the CHF. With respect to the evaluation of the bonds between carbon-based material and heat sink metal, results of brazing tests were compared with the analytical results by three dimensional model with temperature-dependent thermal and mechanical properties. Analytical results showed that residual stresses from brazing can be estimated by the analytical three directional stress values instead of the equivalent stress value applied. In the analytical study on the separatrix sweeping for effectively reducing surface heat fluxes on the divertor plate, thermal response of the divertor plate was analyzed under ITER relevant heat flux conditions and has been tested. As the result, it has been demonstrated that application of the sweeping technique is very effective for improvement in the power handling capability of the divertor plate and that the divertor mock-up has withstood a large number of additional cyclic heat loads.
Analytic posteriors for Pearson's correlation coefficient.
Ly, Alexander; Marsman, Maarten; Wagenmakers, Eric-Jan
2018-02-01
Pearson's correlation is one of the most common measures of linear dependence. Recently, Bernardo (11th International Workshop on Objective Bayes Methodology, 2015) introduced a flexible class of priors to study this measure in a Bayesian setting. For this large class of priors, we show that the (marginal) posterior for Pearson's correlation coefficient and all of the posterior moments are analytic. Our results are available in the open-source software package JASP.
Stability studies of amphetamine and ephedrine derivatives in urine.
Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R
2006-10-20
Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.
NASA Astrophysics Data System (ADS)
Tahri, Meryem; Maanan, Mohamed; Hakdaoui, Mustapha
2016-04-01
This paper shows a method to assess the vulnerability of coastal risks such as coastal erosion or submarine applying Fuzzy Analytic Hierarchy Process (FAHP) and spatial analysis techniques with Geographic Information System (GIS). The coast of the Mohammedia located in Morocco was chosen as the study site to implement and validate the proposed framework by applying a GIS-FAHP based methodology. The coastal risk vulnerability mapping follows multi-parametric causative factors as sea level rise, significant wave height, tidal range, coastal erosion, elevation, geomorphology and distance to an urban area. The Fuzzy Analytic Hierarchy Process methodology enables the calculation of corresponding criteria weights. The result shows that the coastline of the Mohammedia is characterized by a moderate, high and very high level of vulnerability to coastal risk. The high vulnerability areas are situated in the east at Monika and Sablette beaches. This technical approach is based on the efficiency of the Geographic Information System tool based on Fuzzy Analytical Hierarchy Process to help decision maker to find optimal strategies to minimize coastal risks.
Automated Deployment of Advanced Controls and Analytics in Buildings
NASA Astrophysics Data System (ADS)
Pritoni, Marco
Buildings use 40% of primary energy in the US. Recent studies show that developing energy analytics and enhancing control strategies can significantly improve their energy performance. However, the deployment of advanced control software applications has been mostly limited to academic studies. Larger-scale implementations are prevented by the significant engineering time and customization required, due to significant differences among buildings. This study demonstrates how physics-inspired data-driven models can be used to develop portable analytics and control applications for buildings. Specifically, I demonstrate application of these models in all phases of the deployment of advanced controls and analytics in buildings: in the first phase, "Site Preparation and Interface with Legacy Systems" I used models to discover or map relationships among building components, automatically gathering metadata (information about data points) necessary to run the applications. During the second phase: "Application Deployment and Commissioning", models automatically learn system parameters, used for advanced controls and analytics. In the third phase: "Continuous Monitoring and Verification" I utilized models to automatically measure the energy performance of a building that has implemented advanced control strategies. In the conclusions, I discuss future challenges and suggest potential strategies for these innovative control systems to be widely deployed in the market. This dissertation provides useful new tools in terms of procedures, algorithms, and models to facilitate the automation of deployment of advanced controls and analytics and accelerate their wide adoption in buildings.
Tobiszewski, Marek; Orłowski, Aleksander
2015-03-27
The study presents the possibility of multi-criteria decision analysis (MCDA) application when choosing analytical procedures with low environmental impact. A type of MCDA, Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE), was chosen as versatile tool that meets all the analytical chemists--decision makers requirements. Twenty five analytical procedures for aldrin determination in water samples (as an example) were selected as input alternatives to MCDA analysis. Nine different criteria describing the alternatives were chosen from different groups--metrological, economical and the most importantly--environmental impact. The weights for each criterion were obtained from questionnaires that were sent to experts, giving three different scenarios for MCDA results. The results of analysis show that PROMETHEE is very promising tool to choose the analytical procedure with respect to its greenness. The rankings for all three scenarios placed solid phase microextraction and liquid phase microextraction--based procedures high, while liquid-liquid extraction, solid phase extraction and stir bar sorptive extraction--based procedures were placed low in the ranking. The results show that although some of the experts do not intentionally choose green analytical chemistry procedures, their MCDA choice is in accordance with green chemistry principles. The PROMETHEE ranking results were compared with more widely accepted green analytical chemistry tools--NEMI and Eco-Scale. As PROMETHEE involved more different factors than NEMI, the assessment results were only weakly correlated. Oppositely, the results of Eco-Scale assessment were well-correlated as both methodologies involved similar criteria of assessment. Copyright © 2015 Elsevier B.V. All rights reserved.
Effect of storage duration on cytokine stability in human serum and plasma.
Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James
2018-06-14
Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fahie, Monifa A; Chen, Min
2015-08-13
The flexible loops decorating the entrance of OmpG nanopore move dynamically during ionic current recording. The gating caused by these flexible loops changes when a target protein is bound. The gating is characterized by parameters including frequency, duration, and open-pore current, and these features combine to reveal the identity of a specific analyte protein. Here, we show that OmpG nanopore equipped with a biotin ligand can distinguish glycosylated and deglycosylated isoforms of avidin by their differences in surface charge. Our studies demonstrate that the direct interaction between the nanopore and analyte surface, induced by the electrostatic attraction between the two molecules, is essential for protein isoform detection. Our technique is remarkably sensitive to the analyte surface, which may provide a useful tool for glycoprotein profiling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zou, Ling; Zhao, Haihua; Zhang, Hongbin
Here, the one-dimensional water faucet problem is one of the classical benchmark problems originally proposed by Ransom to study the two-fluid two-phase flow model. With certain simplifications, such as massless gas phase and no wall and interfacial frictions, analytical solutions had been previously obtained for the transient liquid velocity and void fraction distribution. The water faucet problem and its analytical solutions have been widely used for the purposes of code assessment, benchmark and numerical verifications. In our previous study, the Ransom’s solutions were used for the mesh convergence study of a high-resolution spatial discretization scheme. It was found that, atmore » the steady state, an anticipated second-order spatial accuracy could not be achieved, when compared to the existing Ransom’s analytical solutions. A further investigation showed that the existing analytical solutions do not actually satisfy the commonly used two-fluid single-pressure two-phase flow equations. In this work, we present a new set of analytical solutions of the water faucet problem at the steady state, considering the gas phase density’s effect on pressure distribution. This new set of analytical solutions are used for mesh convergence studies, from which anticipated second-order of accuracy is achieved for the 2nd order spatial discretization scheme. In addition, extended Ransom’s transient solutions for the gas phase velocity and pressure are derived, with the assumption of decoupled liquid and gas pressures. Numerical verifications on the extended Ransom’s solutions are also presented.« less
Study of tethered satellite active attitude control
NASA Technical Reports Server (NTRS)
Colombo, G.
1982-01-01
Existing software was adapted for the study of tethered subsatellite rotational dynamics, an analytic solution for a stable configuration of a tethered subsatellite was developed, the analytic and numerical integrator (computer) solutions for this "test case' was compared in a two mass tether model program (DUMBEL), the existing multiple mass tether model (SKYHOOK) was modified to include subsatellite rotational dynamics, the analytic "test case,' was verified, and the use of the SKYHOOK rotational dynamics capability with a computer run showing the effect of a single off axis thruster on the behavior of the subsatellite was demonstrated. Subroutines for specific attitude control systems are developed and applied to the study of the behavior of the tethered subsatellite under realistic on orbit conditions. The effect of all tether "inputs,' including pendular oscillations, air drag, and electrodynamic interactions, on the dynamic behavior of the tether are included.
Experimental Validation of the Transverse Shear Behavior of a Nomex Core for Sandwich Panels
NASA Astrophysics Data System (ADS)
Farooqi, M. I.; Nasir, M. A.; Ali, H. M.; Ali, Y.
2017-05-01
This work deals with determination of the transverse shear moduli of a Nomex® honeycomb core of sandwich panels. Their out-of-plane shear characteristics depend on the transverse shear moduli of the honeycomb core. These moduli were determined experimentally, numerically, and analytically. Numerical simulations were performed by using a unit cell model and three analytical approaches. Analytical calculations showed that two of the approaches provided reasonable predictions for the transverse shear modulus as compared with experimental results. However, the approach based upon the classical lamination theory showed large deviations from experimental data. Numerical simulations also showed a trend similar to that resulting from the analytical models.
2017-01-01
Background Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Materials and Methods Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician’s request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. Results The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results. PMID:28107395
Najat, Dereen
2017-01-01
Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician's request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results.
Surface temperature effect on subsonic stall.
NASA Technical Reports Server (NTRS)
Macha, J. M.; Norton, D. J.; Young, J. C.
1972-01-01
Results of an analytical and experimental study of boundary layer flow over an aerodynamic surface rejecting heat to a cool environment. This occurs following reentry of a Space Shuttle vehicle. Analytical studies revealed that a surface to freestream temperature ratio, greater than unity tended to destabilize the boundary layer, hastening transition and separation. Therefore, heat transfer accentuated the effect of an adverse pressure gradient. Wind tunnel tests of a 0012-64 NACA airfoil showed that the stall angle was significantly reduced while drag tended to increase for freestream temperature ratios up to 2.2.
Analytical studies on the instabilities of heterogeneous intelligent traffic flow
NASA Astrophysics Data System (ADS)
Ngoduy, D.
2013-10-01
It has been widely reported in literature that a small perturbation in traffic flow such as a sudden deceleration of a vehicle could lead to the formation of traffic jams without a clear bottleneck. These traffic jams are usually related to instabilities in traffic flow. The applications of intelligent traffic systems are a potential solution to reduce the amplitude or to eliminate the formation of such traffic instabilities. A lot of research has been conducted to theoretically study the effect of intelligent vehicles, for example adaptive cruise control vehicles, using either computer simulation or analytical method. However, most current analytical research has only applied to single class traffic flow. To this end, the main topic of this paper is to perform a linear stability analysis to find the stability threshold of heterogeneous traffic flow using microscopic models, particularly the effect of intelligent vehicles on heterogeneous (or multi-class) traffic flow instabilities. The analytical results will show how intelligent vehicle percentages affect the stability of multi-class traffic flow.
Heat Transfer Analysis of Thermal Protection Structures for Hypersonic Vehicles
NASA Astrophysics Data System (ADS)
Zhou, Chen; Wang, Zhijin; Hou, Tianjiao
2017-11-01
This research aims to develop an analytical approach to study the heat transfer problem of thermal protection systems (TPS) for hypersonic vehicles. Laplace transform and integral method are used to describe the temperature distribution through the TPS subject to aerodynamic heating during flight. Time-dependent incident heat flux is also taken into account. Two different cases with heat flux and radiation boundary conditions are studied and discussed. The results are compared with those obtained by finite element analyses and show a good agreement. Although temperature profiles of such problems can be readily accessed via numerical simulations, analytical solutions give a greater insight into the physical essence of the heat transfer problem. Furthermore, with the analytical approach, rapid thermal analyses and even thermal optimization can be achieved during the preliminary TPS design.
Note on the coefficient of variations of neuronal spike trains.
Lengler, Johannes; Steger, Angelika
2017-08-01
It is known that many neurons in the brain show spike trains with a coefficient of variation (CV) of the interspike times of approximately 1, thus resembling the properties of Poisson spike trains. Computational studies have been able to reproduce this phenomenon. However, the underlying models were too complex to be examined analytically. In this paper, we offer a simple model that shows the same effect but is accessible to an analytic treatment. The model is a random walk model with a reflecting barrier; we give explicit formulas for the CV in the regime of excess inhibition. We also analyze the effect of probabilistic synapses in our model and show that it resembles previous findings that were obtained by simulation.
White, Alec F.; Head-Gordon, Martin; McCurdy, C. William
2017-01-30
The computation of Siegert energies by analytic continuation of bound state energies has recently been applied to shape resonances in polyatomic molecules by several authors. Here, we critically evaluate a recently proposed analytic continuation method based on low order (type III) Padé approximants as well as an analytic continuation method based on high order (type II) Padé approximants. We compare three classes of stabilizing potentials: Coulomb potentials, Gaussian potentials, and attenuated Coulomb potentials. These methods are applied to a model potential where the correct answer is known exactly and to the 2Π g shape resonance of N 2 - whichmore » has been studied extensively by other methods. Both the choice of stabilizing potential and method of analytic continuation prove to be important to the accuracy of the results. We then conclude that an attenuated Coulomb potential is the most effective of the three for bound state analytic continuation methods. With the proper potential, such methods show promise for algorithmic determination of the positions and widths of molecular shape resonances.« less
Li, Zhenlong; Yang, Chaowei; Jin, Baoxuan; Yu, Manzhu; Liu, Kai; Sun, Min; Zhan, Matthew
2015-01-01
Geoscience observations and model simulations are generating vast amounts of multi-dimensional data. Effectively analyzing these data are essential for geoscience studies. However, the tasks are challenging for geoscientists because processing the massive amount of data is both computing and data intensive in that data analytics requires complex procedures and multiple tools. To tackle these challenges, a scientific workflow framework is proposed for big geoscience data analytics. In this framework techniques are proposed by leveraging cloud computing, MapReduce, and Service Oriented Architecture (SOA). Specifically, HBase is adopted for storing and managing big geoscience data across distributed computers. MapReduce-based algorithm framework is developed to support parallel processing of geoscience data. And service-oriented workflow architecture is built for supporting on-demand complex data analytics in the cloud environment. A proof-of-concept prototype tests the performance of the framework. Results show that this innovative framework significantly improves the efficiency of big geoscience data analytics by reducing the data processing time as well as simplifying data analytical procedures for geoscientists. PMID:25742012
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Alec F.; Head-Gordon, Martin; McCurdy, C. William
The computation of Siegert energies by analytic continuation of bound state energies has recently been applied to shape resonances in polyatomic molecules by several authors. Here, we critically evaluate a recently proposed analytic continuation method based on low order (type III) Padé approximants as well as an analytic continuation method based on high order (type II) Padé approximants. We compare three classes of stabilizing potentials: Coulomb potentials, Gaussian potentials, and attenuated Coulomb potentials. These methods are applied to a model potential where the correct answer is known exactly and to the 2Π g shape resonance of N 2 - whichmore » has been studied extensively by other methods. Both the choice of stabilizing potential and method of analytic continuation prove to be important to the accuracy of the results. We then conclude that an attenuated Coulomb potential is the most effective of the three for bound state analytic continuation methods. With the proper potential, such methods show promise for algorithmic determination of the positions and widths of molecular shape resonances.« less
Li, Zhenlong; Yang, Chaowei; Jin, Baoxuan; Yu, Manzhu; Liu, Kai; Sun, Min; Zhan, Matthew
2015-01-01
Geoscience observations and model simulations are generating vast amounts of multi-dimensional data. Effectively analyzing these data are essential for geoscience studies. However, the tasks are challenging for geoscientists because processing the massive amount of data is both computing and data intensive in that data analytics requires complex procedures and multiple tools. To tackle these challenges, a scientific workflow framework is proposed for big geoscience data analytics. In this framework techniques are proposed by leveraging cloud computing, MapReduce, and Service Oriented Architecture (SOA). Specifically, HBase is adopted for storing and managing big geoscience data across distributed computers. MapReduce-based algorithm framework is developed to support parallel processing of geoscience data. And service-oriented workflow architecture is built for supporting on-demand complex data analytics in the cloud environment. A proof-of-concept prototype tests the performance of the framework. Results show that this innovative framework significantly improves the efficiency of big geoscience data analytics by reducing the data processing time as well as simplifying data analytical procedures for geoscientists.
Global entanglement and quantum phase transitions in the transverse XY Heisenberg chain
NASA Astrophysics Data System (ADS)
Radgohar, Roya; Montakhab, Afshin
2018-01-01
We provide a study of various quantum phase transitions occurring in the XY Heisenberg chain in a transverse magnetic field using the Meyer-Wallach (MW) measure of (global) entanglement. Such a measure, while being readily evaluated, is a multipartite measure of entanglement as opposed to more commonly used bipartite measures. Consequently, we obtain analytic expression of the measure for finite-size systems and show that it can be used to obtain critical exponents via finite-size scaling with great accuracy for the Ising universality class. We also calculate an analytic expression for the isotropic (XX) model and show that global entanglement can precisely identify the level-crossing points. The critical exponent for the isotropic transition is obtained exactly from an analytic expression for global entanglement in the thermodynamic limit. Next, the general behavior of the measure is calculated in the thermodynamic limit considering the important role of symmetries for this limit. The so-called oscillatory transition in the ferromagnetic regime can only be characterized by the thermodynamic limit where global entanglement is shown to be zero on the transition curve. Finally, the anisotropic transition is explored where it is shown that global entanglement exhibits an interesting behavior in the finite-size limit. In the thermodynamic limit, we show that global entanglement shows a cusp singularity across the Ising and anisotropic transition, while showing non-analytic behavior at the XX multicritical point. It is concluded that global entanglement, despite its relative simplicity, can be used to identify all the rich structure of the ground-state Heisenberg chain.
Analysis of mode-locked and intracavity frequency-doubled Nd:YAG laser
NASA Technical Reports Server (NTRS)
Siegman, A. E.; Heritier, J.-M.
1980-01-01
The paper presents analytical and computer studies of the CW mode-locked and intracavity frequency-doubled Nd:YAG laser which provide new insight into the operation, including the detuning behavior, of this type of laser. Computer solutions show that the steady-state pulse shape for this laser is much closer to a truncated cosine than to a Gaussian; there is little spectral broadening for on-resonance operation; and the chirp is negligible. This leads to a simplified analytical model carried out entirely in the time domain, with atomic linewidth effects ignored. Simple analytical results for on-resonance pulse shape, pulse width, signal intensity, and harmonic conversion efficiency in terms of basic laser parameters are derived from this model. A simplified physical description of the detuning behavior is also developed. Agreement is found with experimental studies showing that the pulsewidth decreases as the modulation frequency is detuned off resonance; the harmonic power output initially increases and then decreases; and the pulse shape develops a sharp-edged asymmetry of opposite sense for opposite signs of detuning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Y. B.; Zhu, X. W., E-mail: xiaowuzhu1026@znufe.edu.cn; Dai, H. H.
Though widely used in modelling nano- and micro- structures, Eringen’s differential model shows some inconsistencies and recent study has demonstrated its differences between the integral model, which then implies the necessity of using the latter model. In this paper, an analytical study is taken to analyze static bending of nonlocal Euler-Bernoulli beams using Eringen’s two-phase local/nonlocal model. Firstly, a reduction method is proved rigorously, with which the integral equation in consideration can be reduced to a differential equation with mixed boundary value conditions. Then, the static bending problem is formulated and four types of boundary conditions with various loadings aremore » considered. By solving the corresponding differential equations, exact solutions are obtained explicitly in all of the cases, especially for the paradoxical cantilever beam problem. Finally, asymptotic analysis of the exact solutions reveals clearly that, unlike the differential model, the integral model adopted herein has a consistent softening effect. Comparisons are also made with existing analytical and numerical results, which further shows the advantages of the analytical results obtained. Additionally, it seems that the once controversial nonlocal bar problem in the literature is well resolved by the reduction method.« less
Engine isolation for structural-borne interior noise reduction in a general aviation aircraft
NASA Technical Reports Server (NTRS)
Unruh, J. F.; Scheidt, D. C.
1981-01-01
Engine vibration isolation for structural-borne interior noise reduction is investigated. A laboratory based test procedure to simulate engine induced structure-borne noise transmission, the testing of a range of candidate isolators for relative performance data, and the development of an analytical model of the transmission phenomena for isolator design evaluation are addressed. The isolator relative performance test data show that the elastomeric isolators do not appear to operate as single degree of freedom systems with respect to noise isolation. Noise isolation beyond 150 Hz levels off and begins to decrease somewhat above 600 Hz. Coupled analytical and empirical models were used to study the structure-borne noise transmission phenomena. Correlation of predicted results with measured data show that (1) the modeling procedures are reasonably accurate for isolator design evaluation, (2) the frequency dependent properties of the isolators must be included in the model if reasonably accurate noise prediction beyond 150 Hz is desired. The experimental and analytical studies were carried out in the frequency range from 10 Hz to 1000 Hz.
Bigler, Erin D; Farrer, Thomas J; Pertab, Jon L; James, Kelly; Petrie, Jo Ann; Hedges, Dawson W
2013-01-01
In 2009 Pertab, James, and Bigler published a critique of two prior meta-analyses by Binder, Rohling, and Larrabee (1997) and Frencham, Fox, and Maybery (2005) that showed small effect size difference at least 3 months post-injury in individuals who had sustained a mild traumatic brain injury (mTBI). The Binder et al. and Frencham et al. meta-analyses have been widely cited as showing no lasting effect of mTBI. In their critique Pertab et al. (2009) point out many limitations of these two prior meta-analyses, demonstrating that depending on how inclusion/exclusion criteria were defined different meta-analytic findings occur, some supporting the persistence of neuropsychological impairments beyond 3 months. Rohling et al. (2011) have now critiqued Pertab et al. (2009). Herein we respond to the Rolling et al. (2011) critique reaffirming the original findings of Pertab et al. (2009), providing additional details concerning the flaws in prior meta-analytic mTBI studies and the effects on neuropsychological performance.
Mechanics of additively manufactured porous biomaterials based on the rhombicuboctahedron unit cell.
Hedayati, R; Sadighi, M; Mohammadi-Aghdam, M; Zadpoor, A A
2016-01-01
Thanks to recent developments in additive manufacturing techniques, it is now possible to fabricate porous biomaterials with arbitrarily complex micro-architectures. Micro-architectures of such biomaterials determine their physical and biological properties, meaning that one could potentially improve the performance of such biomaterials through rational design of micro-architecture. The relationship between the micro-architecture of porous biomaterials and their physical and biological properties has therefore received increasing attention recently. In this paper, we studied the mechanical properties of porous biomaterials made from a relatively unexplored unit cell, namely rhombicuboctahedron. We derived analytical relationships that relate the micro-architecture of such porous biomaterials, i.e. the dimensions of the rhombicuboctahedron unit cell, to their elastic modulus, Poisson's ratio, and yield stress. Finite element models were also developed to validate the analytical solutions. Analytical and numerical results were compared with experimental data from one of our recent studies. It was found that analytical solutions and numerical results show a very good agreement particularly for smaller values of apparent density. The elastic moduli predicted by analytical and numerical models were in very good agreement with experimental observations too. While in excellent agreement with each other, analytical and numerical models somewhat over-predicted the yield stress of the porous structures as compared to experimental data. As the ratio of the vertical struts to the inclined struts, α, approaches zero and infinity, the rhombicuboctahedron unit cell respectively approaches the octahedron (or truncated cube) and cube unit cells. For those limits, the analytical solutions presented here were found to approach the analytic solutions obtained for the octahedron, truncated cube, and cube unit cells, meaning that the presented solutions are generalizations of the analytical solutions obtained for several other types of porous biomaterials. Copyright © 2015 Elsevier Ltd. All rights reserved.
Risk prioritisation using the analytic hierarchy process
NASA Astrophysics Data System (ADS)
Sum, Rabihah Md.
2015-12-01
This study demonstrated how to use the Analytic Hierarchy Process (AHP) to prioritise risks of an insurance company. AHP is a technique to structure complex problems by arranging elements of the problems in a hierarchy, assigning numerical values to subjective judgements on the relative importance of the elements and synthesizing the judgements to determine which elements have the highest priority. The study is motivated by wide application of AHP as a prioritisation technique in complex problems. It aims to show AHP is able to minimise some limitations of risk assessment technique using likelihood and impact. The study shows AHP is able to provide consistency check on subjective judgements, organise a large number of risks into a structured framework, assist risk managers to make explicit risk trade-offs, and provide an easy to understand and systematic risk assessment process.
Parrinello, Christina M.; Grams, Morgan E.; Couper, David; Ballantyne, Christie M.; Hoogeveen, Ron C.; Eckfeldt, John H.; Selvin, Elizabeth; Coresh, Josef
2016-01-01
Background Equivalence of laboratory tests over time is important for longitudinal studies. Even a small systematic difference (bias) can result in substantial misclassification. Methods We selected 200 Atherosclerosis Risk in Communities Study participants attending all 5 study visits over 25 years. Eight analytes were re-measured in 2011–13 from stored blood samples from multiple visits: creatinine, uric acid, glucose, total cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides, and high-sensitivity C-reactive protein. Original values were recalibrated to re-measured values using Deming regression. Differences >10% were considered to reflect substantial bias, and correction equations were applied to affected analytes in the total study population. We examined trends in chronic kidney disease (CKD) pre- and post-recalibration. Results Repeat measures were highly correlated with original values (Pearson’s r>0.85 after removing outliers [median 4.5% of paired measurements]), but 2 of 8 analytes (creatinine and uric acid) had differences >10%. Original values of creatinine and uric acid were recalibrated to current values using correction equations. CKD prevalence differed substantially after recalibration of creatinine (visits 1, 2, 4 and 5 pre-recalibration: 21.7%, 36.1%, 3.5%, 29.4%; post-recalibration: 1.3%, 2.2%, 6.4%, 29.4%). For HDL-cholesterol, the current direct enzymatic method differed substantially from magnesium dextran precipitation used during visits 1–4. Conclusions Analytes re-measured in samples stored for ~25 years were highly correlated with original values, but two of the 8 analytes showed substantial bias at multiple visits. Laboratory recalibration improved reproducibility of test results across visits and resulted in substantial differences in CKD prevalence. We demonstrate the importance of consistent recalibration of laboratory assays in a cohort study. PMID:25952043
Investigation on the Interface Morphologies of Explosive Welding of Inconel 625 to Steel A516 Plates
NASA Astrophysics Data System (ADS)
Mousavi, S. A. A. Akbari; Zareie, H. R.
2011-01-01
The purpose of this study is to produce composite plates by explosive cladding process. This is a process in which the controlled energy of explosives is used to create a metallic bond between two similar or dissimilar materials. The welding conditions were tailored through parallel geometry route with different operational parameters. In this investigation, a two-pronged study was adopted to establish the conditions required for producing successful solid state welding: (a) Analytical calculations to determine the weldability domain or welding window; (b) Metallurgical investigations of explosive welding experiments carried out under different explosive ratios to produce both wavy and straight interfaces. The analytical calculations confirm the experimental results. Optical microscopy studies show that a transition from a smooth to wavy interface occurs with an increase in explosive ratio. SEM studies show that the interface was outlined by characteristic sharp transition between two materials.
NASA Astrophysics Data System (ADS)
Lestariningsih, Titik; Ratri, Christin Rina; Wigayati, Etty Marty; Sabrina, Qolby
2016-02-01
Characterization of pore structure and crystal structure of the LiB(C2O4)2H2O or LIBOB compound has been performed in this study. These recent years, research regarding LiBOB electrolyte salt have been performed using analytical-grade raw materials, therefore this research was aimed to synthesized LiBOB electrolyte salt using the cheaper and abundant technical-grade raw materials. Lithium hydroxide (LiOH), oxalic acid dihydrate (H2C2O4.2H2O), and boric acid (H3BO3) both in technical-grade and analytical-grade quality were used as raw materials for the synthesis of LiBOB. Crystal structure characterization results of synthesized LiBOB from both technical-grade and analytical-grade raw materials have shown the existence of LiBOB and LiBOB hydrate phase with orthorombic structure. These results were also confirmed by FT-IR analysis, which showed the functional groups of LiBOB compounds. SEM analysis results showed that synthesized LiBOB has spherical structure, while commercial LiBOB has cylindrical structure. Synthesized LiBOB has a similar pore size of commercial LiBOB, i.e. 19 nm (mesoporous material). Surface area of synthesized LiBOB from analytical-grade raw materials and technical-grade materials as well as commercial LIBOB were 88.556 m2/g, 41.524 m2/g, and 108.776 m2/g, respectively. EIS analysis results showed that synthesized LiBOB from technical-grade raw materials has lower conductivity than synthesized LiBOB from analytical-grade raw materials.
Mangas-Sanjuan, Victor; Navarro-Fontestad, Carmen; García-Arieta, Alfredo; Trocóniz, Iñaki F; Bermejo, Marival
2018-05-30
A semi-physiological two compartment pharmacokinetic model with two active metabolites (primary (PM) and secondary metabolites (SM)) with saturable and non-saturable pre-systemic efflux transporter, intestinal and hepatic metabolism has been developed. The aim of this work is to explore in several scenarios which analyte (parent drug or any of the metabolites) is the most sensitive to changes in drug product performance (i.e. differences in in vivo dissolution) and to make recommendations based on the simulations outcome. A total of 128 scenarios (2 Biopharmaceutics Classification System (BCS) drug types, 2 levels of K M Pgp , in 4 metabolic scenarios at 2 dose levels in 4 quality levels of the drug product) were simulated for BCS class II and IV drugs. Monte Carlo simulations of all bioequivalence studies were performed in NONMEM 7.3. Results showed the parent drug (PD) was the most sensitive analyte for bioequivalence trials in all the studied scenarios. PM and SM revealed less or the same sensitivity to detect differences in pharmaceutical quality as the PD. Another relevant result is that mean point estimate of C max and AUC methodology from Monte Carlo simulations allows to select more accurately the most sensitive analyte compared to the criterion on the percentage of failed or successful BE studies, even for metabolites which frequently show greater variability than PD. Copyright © 2018 Elsevier B.V. All rights reserved.
Measuring salivary analytes from free-ranging monkeys
Higham, James P.; Vitale, Alison; Rivera, Adaris Mas; Ayala, James E.; Maestripieri, Dario
2014-01-01
Studies of large free-ranging mammals have been revolutionized by non-invasive methods for assessing physiology, which usually involve the measurement of fecal or urinary biomarkers. However, such techniques are limited by numerous factors. To expand the range of physiological variables measurable non-invasively from free-ranging primates, we developed techniques for sampling monkey saliva by offering monkeys ropes with oral swabs sewn on the ends. We evaluated different attractants for encouraging individuals to offer samples, and proportions of individuals in different age/sex categories willing to give samples. We tested the saliva samples we obtained in three commercially available assays: cortisol, Salivary Alpha Amylase, and Secretory Immunoglobulin A. We show that habituated free-ranging rhesus macaques will give saliva samples voluntarily without training, with 100% of infants, and over 50% of adults willing to chew on collection devices. Our field methods are robust even for analytes that show poor recovery from cotton, and/or that have concentrations dependent on salivary flow rate. We validated the cortisol and SAA assays for use in rhesus macaques by showing aspects of analytical validation, such as that samples dilute linearly and in parallel to assay standards. We also found that values measured correlated with biologically meaningful characteristics of sampled individuals (age and dominance rank). The SIgA assay tested did not react to samples. Given the wide range of analytes measurable in saliva but not in feces or urine, our methods considerably improve our ability to study physiological aspects of the behavior and ecology of free-ranging primates, and are also potentially adaptable to other mammalian taxa. PMID:20837036
An Analytical-Numerical Model for Two-Phase Slug Flow through a Sudden Area Change in Microchannels
Momen, A. Mehdizadeh; Sherif, S. A.; Lear, W. E.
2016-01-01
In this article, two new analytical models have been developed to calculate two-phase slug flow pressure drop in microchannels through a sudden contraction. Even though many studies have been reported on two-phase flow in microchannels, considerable discrepancies still exist, mainly due to the difficulties in experimental setup and measurements. Numerical simulations were performed to support the new analytical models and to explore in more detail the physics of the flow in microchannels with a sudden contraction. Both analytical and numerical results were compared to the available experimental data and other empirical correlations. Results show that models, which were developed basedmore » on the slug and semi-slug assumptions, agree well with experiments in microchannels. Moreover, in contrast to the previous empirical correlations which were tuned for a specific geometry, the new analytical models are capable of taking geometrical parameters as well as flow conditions into account.« less
European Multicenter Study on Analytical Performance of DxN Veris System HCV Assay.
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Gismondo, Maria Rita; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Marcos, Maria Angeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W
2017-04-01
The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log 10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log 10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites. Copyright © 2017 American Society for Microbiology.
Analytical close-form solutions to the elastic fields of solids with dislocations and surface stress
NASA Astrophysics Data System (ADS)
Ye, Wei; Paliwal, Bhasker; Ougazzaden, Abdallah; Cherkaoui, Mohammed
2013-07-01
The concept of eigenstrain is adopted to derive a general analytical framework to solve the elastic field for 3D anisotropic solids with general defects by considering the surface stress. The formulation shows the elastic constants and geometrical features of the surface play an important role in determining the elastic fields of the solid. As an application, the analytical close-form solutions to the stress fields of an infinite isotropic circular nanowire are obtained. The stress fields are compared with the classical solutions and those of complex variable method. The stress fields from this work demonstrate the impact from the surface stress when the size of the nanowire shrinks but becomes negligible in macroscopic scale. Compared with the power series solutions of complex variable method, the analytical solutions in this work provide a better platform and they are more flexible in various applications. More importantly, the proposed analytical framework profoundly improves the studies of general 3D anisotropic materials with surface effects.
2017-08-01
of metallic additive manufacturing processes and show that combining experimental data with modelling and advanced data processing and analytics...manufacturing processes and show that combining experimental data with modelling and advanced data processing and analytics methods will accelerate that...geometries, we develop a methodology that couples experimental data and modelling to convert the scan paths into spatially resolved local thermal histories
Pravdin, Sergey F.; Dierckx, Hans; Katsnelson, Leonid B.; Solovyova, Olga; Markhasin, Vladimir S.; Panfilov, Alexander V.
2014-01-01
We develop a numerical approach based on our recent analytical model of fiber structure in the left ventricle of the human heart. A special curvilinear coordinate system is proposed to analytically include realistic ventricular shape and myofiber directions. With this anatomical model, electrophysiological simulations can be performed on a rectangular coordinate grid. We apply our method to study the effect of fiber rotation and electrical anisotropy of cardiac tissue (i.e., the ratio of the conductivity coefficients along and across the myocardial fibers) on wave propagation using the ten Tusscher–Panfilov (2006) ionic model for human ventricular cells. We show that fiber rotation increases the speed of cardiac activation and attenuates the effects of anisotropy. Our results show that the fiber rotation in the heart is an important factor underlying cardiac excitation. We also study scroll wave dynamics in our model and show the drift of a scroll wave filament whose velocity depends non-monotonically on the fiber rotation angle; the period of scroll wave rotation decreases with an increase of the fiber rotation angle; an increase in anisotropy may cause the breakup of a scroll wave, similar to the mother rotor mechanism of ventricular fibrillation. PMID:24817308
Dervisevic, Muamer; Şenel, Mehmet; Sagir, Tugba; Isik, Sevim
2017-05-15
A comparative study is reported where folic acid (FA) and boronic acid (BA) based cytosensors and their analytical performances in cancer cell detection were analyzed by using electrochemical impedance spectroscopy (EIS) method. Cytosensors were fabricated using self-assembled monolayer principle by modifying Au electrode with cysteamine (Cys) and immobilization of ferrocene cored polyamidiamine dendrimers second generation (Fc-PAMAM (G2)), after which electrodes were modified with FA and BA. Au/Fc-PAMAM(G2)/FA and Au/Fc-PAMAM(G2)/BA based cytosensors showed extremely good analytical performances in cancer cell detection with linear range of 1×10 2 to 1×10 6 cellsml -1 , detection limit of 20cellsml -1 with incubation time of 20min for FA based electrode, and for BA based electrode detection limit was 28cellsml -1 with incubation time of 10min. Next to excellent analytical performances, cytosensors showed high selectivity towards cancer cells which was demonstrated in selectivity study using human embryonic kidney 293 cells (HEK 293) as normal cells and Au/Fc-PAMAM(G2)/FA electrode showed two times better selectivity than BA modified electrode. These cytosensors are promising for future applications in cancer cell diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Validation of the SINDA/FLUINT code using several analytical solutions
NASA Technical Reports Server (NTRS)
Keller, John R.
1995-01-01
The Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA/FLUINT) code has often been used to determine the transient and steady-state response of various thermal and fluid flow networks. While this code is an often used design and analysis tool, the validation of this program has been limited to a few simple studies. For the current study, the SINDA/FLUINT code was compared to four different analytical solutions. The thermal analyzer portion of the code (conduction and radiative heat transfer, SINDA portion) was first compared to two separate solutions. The first comparison examined a semi-infinite slab with a periodic surface temperature boundary condition. Next, a small, uniform temperature object (lumped capacitance) was allowed to radiate to a fixed temperature sink. The fluid portion of the code (FLUINT) was also compared to two different analytical solutions. The first study examined a tank filling process by an ideal gas in which there is both control volume work and heat transfer. The final comparison considered the flow in a pipe joining two infinite reservoirs of pressure. The results of all these studies showed that for the situations examined here, the SINDA/FLUINT code was able to match the results of the analytical solutions.
Mechanical Properties of Additively Manufactured Thick Honeycombs.
Hedayati, Reza; Sadighi, Mojtaba; Mohammadi Aghdam, Mohammad; Zadpoor, Amir Abbas
2016-07-23
Honeycombs resemble the structure of a number of natural and biological materials such as cancellous bone, wood, and cork. Thick honeycomb could be also used for energy absorption applications. Moreover, studying the mechanical behavior of honeycombs under in-plane loading could help understanding the mechanical behavior of more complex 3D tessellated structures such as porous biomaterials. In this paper, we study the mechanical behavior of thick honeycombs made using additive manufacturing techniques that allow for fabrication of honeycombs with arbitrary and precisely controlled thickness. Thick honeycombs with different wall thicknesses were produced from polylactic acid (PLA) using fused deposition modelling, i.e., an additive manufacturing technique. The samples were mechanically tested in-plane under compression to determine their mechanical properties. We also obtained exact analytical solutions for the stiffness matrix of thick hexagonal honeycombs using both Euler-Bernoulli and Timoshenko beam theories. The stiffness matrix was then used to derive analytical relationships that describe the elastic modulus, yield stress, and Poisson's ratio of thick honeycombs. Finite element models were also built for computational analysis of the mechanical behavior of thick honeycombs under compression. The mechanical properties obtained using our analytical relationships were compared with experimental observations and computational results as well as with analytical solutions available in the literature. It was found that the analytical solutions presented here are in good agreement with experimental and computational results even for very thick honeycombs, whereas the analytical solutions available in the literature show a large deviation from experimental observation, computational results, and our analytical solutions.
NASA Technical Reports Server (NTRS)
Boyd, D. E.; Rao, C. K. P.
1973-01-01
The derivation and application of a Rayleigh-Ritz modal vibration analysis are presented for ring and/or stringer stiffened noncircular cylindrical shells with arbitrary end conditions. Comparisons with previous results from experimental and analytical studies showed this method of analysis to be accurate for a variety of end conditions. Results indicate a greater effect of rings on natural frequencies than of stringers.
Analytical solution of a stochastic model of risk spreading with global coupling
NASA Astrophysics Data System (ADS)
Morita, Satoru; Yoshimura, Jin
2013-11-01
We study a stochastic matrix model to understand the mechanics of risk spreading (or bet hedging) by dispersion. Up to now, this model has been mostly dealt with numerically, except for the well-mixed case. Here, we present an analytical result that shows that optimal dispersion leads to Zipf's law. Moreover, we found that the arithmetic ensemble average of the total growth rate converges to the geometric one, because the sample size is finite.
Data Analytics of Hydraulic Fracturing Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jovan Yang; Viswanathan, Hari; Hyman, Jeffery
These are a set of slides on the data analytics of hydraulic fracturing data. The conclusions from this research are the following: they proposed a permeability evolution as a new mechanism to explain hydraulic fracturing trends; they created a model to include this mechanism and it showed promising results; the paper from this research is ready for submission; they devised a way to identify and sort refractures in order to study their effects, and this paper is currently being written.
Lu, Liang-Xing; Wang, Ying-Min; Srinivasan, Bharathi Madurai; Asbahi, Mohamed; Yang, Joel K W; Zhang, Yong-Wei
2016-09-01
We perform systematic two-dimensional energetic analysis to study the stability of various nanostructures formed by dewetting solid films deposited on patterned substrates. Our analytical results show that by controlling system parameters such as the substrate surface pattern, film thickness and wetting angle, a variety of equilibrium nanostructures can be obtained. Phase diagrams are presented to show the complex relations between these system parameters and various nanostructure morphologies. We further carry out both phase field simulations and dewetting experiments to validate the analytically derived phase diagrams. Good agreements between the results from our energetic analyses and those from our phase field simulations and experiments verify our analysis. Hence, the phase diagrams presented here provide guidelines for using solid-state dewetting as a tool to achieve various nanostructures.
Chung, Hee-Jung; Song, Yoon Kyung; Hong, Sung Kuk; Hwang, Sang-Hyun; Seo, Hee Seung; Whang, Dong Hee; Nam, Myung-Hyun; Lee, Do Hoon
2017-01-01
Recently, because the quality of laboratory analyses has increased along with the need for quality improvement, several external quality control bodies have adapted performance specifications using the Desirable Biological Variation Database, termed "Ricos goals"; these criteria are more stringent than those presented in CLIA 88. In this study, we aimed to validate newly introduced serum separator tubes, Improvacutor, for routine clinical chemistry testing in accordance with Ricos goals and CLIA 88. Blood samples were collected from 100 volunteers into three types of serum vacuum tubes: Greiner Vacuette, Becton Dickinson (BD) Vacutainer, and Improve Improvacutor. The samples were subjected to 16 routine chemistry tests using a TBA-200fr NEO chemistry autoanalyzer. In the comparison analysis, all 16 test results were acceptable according to CLIA 88. However, in the comparison of Improve and BD tubes, creatinine showed 4.31% (+0.08 μmol/L) bias. This slightly exceeded the Desirable Specification for Inaccuracy Ricos limit of ±3.96%, but still satisfied the CLIS88 limit of ±26.52 μmol/L. The remaining 15 analytes performed acceptably according to the Desirable Specifications of Ricos. The correlation coefficient of 12 analytes was greater than 0.95 in Passing-Bablok regression analysis among the three tubes, but was lower for four analytes: calcium, sodium, potassium, and chloride. In the stability assay, only potassium tested in the Greiner tube revealed a larger positive bias (2.18%) than the Ricos Desirable Specification for Inaccuracy based on biologic variation (1.8%). The BD tube also showed a positive bias of 1.74%, whereas the new Improve tube showed the smallest positive bias of 1.17% in potassium level after 72 h storage. Thus, the results of this study demonstrate that recently introduced analytical performance specifications based on components of biological variation (Rico's goal) could be extended to criterion for performance evaluation and applied.
Del Piero, Larissa B; Saxbe, Darby E; Margolin, Gayla
2016-06-01
Early neuroimaging studies suggested that adolescents show initial development in brain regions linked with emotional reactivity, but slower development in brain structures linked with emotion regulation. However, the increased sophistication of adolescent brain research has made this picture more complex. This review examines functional neuroimaging studies that test for differences in basic emotion processing (reactivity and regulation) between adolescents and either children or adults. We delineated different emotional processing demands across the experimental paradigms in the reviewed studies to synthesize the diverse results. The methods for assessing change (i.e., analytical approach) and cohort characteristics (e.g., age range) were also explored as potential factors influencing study results. Few unifying dimensions were found to successfully distill the results of the reviewed studies. However, this review highlights the potential impact of subtle methodological and analytic differences between studies, need for standardized and theory-driven experimental paradigms, and necessity of analytic approaches that are can adequately test the trajectories of developmental change that have recently been proposed. Recommendations for future research highlight connectivity analyses and non-linear developmental trajectories, which appear to be promising approaches for measuring change across adolescence. Recommendations are made for evaluating gender and biological markers of development beyond chronological age. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Del Piero, Larissa B.; Saxbe, Darby E.; Margolin, Gayla
2016-01-01
Early neuroimaging studies suggested that adolescents show initial development in brain regions linked with emotional reactivity, but slower development in brain structures linked with emotion regulation. However, the increased sophistication of adolescent brain research has made this picture more complex. This review examines functional neuroimaging studies that test for differences in basic emotion processing (reactivity and regulation) between adolescents and either children or adults. We delineated different emotional processing demands across the experimental paradigms in the reviewed studies to synthesize the diverse results. The methods for assessing change (i.e., analytical approach) and cohort characteristics (e.g., age range) were also explored as potential factors influencing study results. Few unifying dimensions were found to successfully distill the results of the reviewed studies. However, this review highlights the potential impact of subtle methodological and analytic differences between studies, need for standardized and theory-driven experimental paradigms, and necessity of analytic approaches that are can adequately test the trajectories of developmental change that have recently been proposed. Recommendations for future research highlight connectivity analyses and nonlinear developmental trajectories, which appear to be promising approaches for measuring change across adolescence. Recommendations are made for evaluating gender and biological markers of development beyond chronological age. PMID:27038840
NASA Astrophysics Data System (ADS)
Andrade-Ines, Eduardo; Robutel, Philippe
2018-01-01
We present an analytical formalism to study the secular dynamics of a system consisting of N-2 planets orbiting a binary star in outer orbits. We introduce a canonical coordinate system and expand the disturbing function in terms of canonical elliptic elements, combining both Legendre polynomials and Laplace coefficients, to obtain a general formalism for the secular description of this type of configuration. With a quadratic approximation of the development, we present a simplified analytical solution for the planetary orbits for both the single planet and the two-planet cases. From the two-planet model, we show that the inner planet accelerates the precession rate of the binary pericenter, which, in turn, may enter in resonance with the secular frequency of the outer planet, characterizing a secular resonance. We calculate an analytical expression for the approximate location of this resonance and apply it to known circumbinary systems, where we show that it can occur at relatively close orbits, for example at 2.4 au for the Kepler-38 system. With a more refined model, we analyse the dynamics of this secular resonance and we show that a bifurcation of the corresponding fixed points can affect the long- term evolution and stability of planetary systems. By comparing our results with complete integrations of the exact equations of motion, we verified the accuracy of our analytical model.
Analytical estimation show low depth-independent water loss due to vapor flux from deep aquifers
NASA Astrophysics Data System (ADS)
Selker, John S.
2017-06-01
Recent articles have provided estimates of evaporative flux from water tables in deserts that span 5 orders of magnitude. In this paper, we present an analytical calculation that indicates aquifer vapor flux to be limited to 0.01 mm/yr for sites where there is negligible recharge and the water table is well over 20 m below the surface. This value arises from the geothermal gradient, and therefore, is nearly independent of the actual depth of the aquifer. The value is in agreement with several numerical studies, but is 500 times lower than recently reported experimental values, and 100 times larger than an earlier analytical estimate.
Flow through three-dimensional arrangements of cylinders with alternating streamwise planar tilt
NASA Astrophysics Data System (ADS)
Sahraoui, M.; Marshall, H.; Kaviany, M.
1993-09-01
In this report, fluid flow through a three-dimensional model for the fibrous filters is examined. In this model, the three-dimensional Stokes equation with the appropriate periodic boundary conditions is solved using the finite volume method. In addition to the numerical solution, we attempt to model this flow analytically by using the two-dimensional extended analytic solution in each of the unit cells of the three-dimensional structure. Particle trajectories computed using the superimposed analytic solution of the flow field are closed to those computed using the numerical solution of the flow field. The numerical results show that the pressure drop is not affected significantly by the relative angle of rotation of the cylinders for the high porosity used in this study (epsilon = 0.8 and epsilon = 0.95). The numerical solution and the superimposed analytic solution are also compared in terms of the particle capture efficiency. The results show that the efficiency predictions using the two methods are within 10% for St = 0.01 and 5% for St = 100. As the the porosity decreases, the three-dimensional effect becomes more significant and a difference of 35% is obtained for epsilon = 0.8.
Analytical dose modeling for preclinical proton irradiation of millimetric targets.
Vanstalle, Marie; Constanzo, Julie; Karakaya, Yusuf; Finck, Christian; Rousseau, Marc; Brasse, David
2018-01-01
Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological effectiveness of proton radiation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the specific constraints imposed by the small dimensions of the irradiated areas. The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was validated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modeling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irradiated with a 24-MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commission on Radiation Units and Measurements for all tested configurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a significant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Good dose accuracy for millimetric tumors is achieved with the analytical calculation used in this work. These volume sizes are typical in mouse models for radiation studies. Our results demonstrate that the choice of analytical rather than simulated treatment planning depends on the animal model under consideration. © 2017 American Association of Physicists in Medicine.
Analytical study of robustness of a negative feedback oscillator by multiparameter sensitivity
2014-01-01
Background One of the distinctive features of biological oscillators such as circadian clocks and cell cycles is robustness which is the ability to resume reliable operation in the face of different types of perturbations. In the previous study, we proposed multiparameter sensitivity (MPS) as an intelligible measure for robustness to fluctuations in kinetic parameters. Analytical solutions directly connect the mechanisms and kinetic parameters to dynamic properties such as period, amplitude and their associated MPSs. Although negative feedback loops are known as common structures to biological oscillators, the analytical solutions have not been presented for a general model of negative feedback oscillators. Results We present the analytical expressions for the period, amplitude and their associated MPSs for a general model of negative feedback oscillators. The analytical solutions are validated by comparing them with numerical solutions. The analytical solutions explicitly show how the dynamic properties depend on the kinetic parameters. The ratio of a threshold to the amplitude has a strong impact on the period MPS. As the ratio approaches to one, the MPS increases, indicating that the period becomes more sensitive to changes in kinetic parameters. We present the first mathematical proof that the distributed time-delay mechanism contributes to making the oscillation period robust to parameter fluctuations. The MPS decreases with an increase in the feedback loop length (i.e., the number of molecular species constituting the feedback loop). Conclusions Since a general model of negative feedback oscillators was employed, the results shown in this paper are expected to be true for many of biological oscillators. This study strongly supports that the hypothesis that phosphorylations of clock proteins contribute to the robustness of circadian rhythms. The analytical solutions give synthetic biologists some clues to design gene oscillators with robust and desired period. PMID:25605374
Biomonitoring at the UK Health and Safety Laboratory.
Cocker, J; Jones, K; Morton, J; Mason, H J
2007-05-01
The UK Health and Safety Laboratory (HSL) provides research and analytical support to the Health and Safety Executive, other Government Departments and employers. In the area of biomonitoring HSL conducts research studies and provides an analytical service for regular surveillance of worker exposure to hazardous substances. This paper gives brief examples of how data from such studies can be used to develop biological monitoring guidance values for isocyanates, polycyclic aromatic hydrocarbons and hexavalent chromium. In addition, a study of occupational exposure to copper chrome arsenic wood preservatives is briefly described to show how biological monitoring can be used for post-approval surveillance of a biocide.
Chepyala, Divyabharathi; Tsai, I-Lin; Liao, Hsiao-Wei; Chen, Guan-Yuan; Chao, Hsi-Chun; Kuo, Ching-Hua
2017-03-31
An increased rate of drug abuse is a major social problem worldwide. The dried blood spot (DBS) sampling technique offers many advantages over using urine or whole blood sampling techniques. This study developed a simple and efficient ultra-high-performance liquid chromatography-ion booster-quadrupole time-of-flight mass spectrometry (UHPLC-IB-QTOF-MS) method for the analysis of abused drugs and their metabolites using DBS. Fifty-seven compounds covering the most commonly abused drugs, including amphetamines, opioids, cocaine, benzodiazepines, barbiturates, and many other new and emerging abused drugs, were selected as the target analytes of this study. An 80% acetonitrile solvent with a 5-min extraction by Geno grinder was used for sample extraction. A Poroshell column was used to provide efficient separation, and under optimal conditions, the analytical times were 15 and 5min in positive and negative ionization modes, respectively. Ionization parameters of both electrospray ionization source and ion booster (IB) source containing an extra heated zone were optimized to achieve the best ionization efficiency of the investigated abused drugs. In spite of their structural diversity, most of the abused drugs showed an enhanced mass response with the high temperature ionization from an extra heated zone of IB source. Compared to electrospray ionization, the ion booster (IB) greatly improved the detection sensitivity for 86% of the analytes by 1.5-14-fold and allowed the developed method to detect trace amounts of compounds on the DBS cards. The validation results showed that the coefficients of variation of intra-day and inter-day precision in terms of the signal intensity were lower than 19.65%. The extraction recovery of all analytes was between 67.21 and 115.14%. The limits of detection of all analytes were between 0.2 and 35.7ngmL -1 . The stability study indicated that 7% of compounds showed poor stability (below 50%) on the DBS cards after 6 months of storage at room temperature and -80°C. The reported method provides a new direction for abused drug screening using DBS. Copyright © 2017 Elsevier B.V. All rights reserved.
Study of Surface Wave Propagation in Fluid-Saturated Porous Solids.
NASA Astrophysics Data System (ADS)
Azcuaga, Valery Francisco Godinez
1995-01-01
This study addresses the surface wave propagation phenomena on fluid-saturated porous solids. The analytical method for calculation of surface wave velocities (Feng and Johnson, JASA, 74, 906, 1983) is extended to the case of a porous solid saturated with a wetting fluid in contact with a non-wetting fluid, in order to study a material combination suitable for experimental investigation. The analytical method is further extended to the case of a non-wetting fluid/wetting fluid-saturated porous solid interface with an arbitrary finite surface stiffness. These extensions of the analytical method allows to theoretically study surface wave propagation phenomena during the saturation process. A modification to the 2-D space-time reflection Green's function (Feng and Johnson, JASA, 74, 915, 1983) is introduced in order to simulate the behavior of surface wave signals detected during the experimental investigation of surface wave propagation on fluid-saturated porous solids (Nagy, Appl. Phys. Lett., 60, 2735, 1992). This modification, together with the introduction of an excess attenuation for the Rayleigh surface mode, makes it possible to explain the apparent velocity changes observed on the surface wave signals during saturation. Experimental results concerning the propagation of surface waves on an alcohol-saturated porous glass are presented. These experiments were performed at frequencies of 500 and 800 kHz and show the simultaneous propagation of the two surface modes predicted by the extended analytical method. Finally an analysis of the displacements associated with the different surface modes is presented. This analysis reveals that it is possible to favor the generation of the Rayleigh surface mode or of the slow surface mode, simply by changing the type of transducer used in the generation of surface waves. Calculations show that a shear transducer couples more energy into the Rayleigh mode, whereas a longitudinal transducer couples more energy into the slow surface mode. Experimental results obtained with the modified experimental system show a qualitative agreement with the theoretical predictions.
Strategy selection in the minority game
NASA Astrophysics Data System (ADS)
D'hulst, R.; Rodgers, G. J.
2000-04-01
We investigate the dynamics of the choice of an active strategy in the minority game. A history distribution is introduced as an analytical tool to study the asymmetry between the two choices offered to the agents. Its properties are studied numerically. It allows us to show that the departure from uniformity in the initial attribution of strategies to the agents is important even in the efficient market. Also, an approximate expression for the variance of the number of agents at one side in the efficient phase is proposed. All the analytical propositions are supported by numerical simulations of the system.
NASA Astrophysics Data System (ADS)
Li, Jiangui; Wang, Junhua; Zhigang, Zhao; Yan, Weili
2012-04-01
In this paper, analytical analysis of the permanent magnet vernier (PMV) is presented. The key is to analytically solve the governing Laplacian/quasi-Poissonian field equations in the motor regions. By using the time-stepping finite element method, the analytical method is verified. Hence, the performances of the PMV machine are quantitatively compared with that of the analytical results. The analytical results agree well with the finite element method results. Finally, the experimental results are given to further show the validity of the analysis.
Friedman, Jared Parker; Jack, Anthony Ian
2018-02-01
Better understanding the psychological factors related to certainty in one's beliefs (i.e., dogmatism) has important consequences for both individuals and social groups. Generally, beliefs can find support from at least two different routes of information processing: social/moral considerations or analytic/empirical reasoning. Here, we investigate how these two psychological constructs relate to dogmatism in two groups of individuals who preferentially draw on the former or latter sort of information when forming beliefs about the world-religious and nonreligious individuals. Across two studies and their pooled analysis, we provide evidence that although dogmatism is negatively related to analytic reasoning in both groups of individuals, it shares a divergent relationship with measures of moral concern depending on whether one identifies as religious or not. Study 1 showed that increasing levels of dogmatism were positively related to prosocial intentions among the religious and negatively related to empathic concern among the nonreligious. Study 2 replicated and extended these results by showing that perspective taking is negatively related to dogmatism in both groups, an effect which is particularly robust among the nonreligious. Study 2 also showed that religious fundamentalism was positively related to measures of moral concern among the religious. Because the current studies used a content-neutral measure to assess dogmatic certainty in one's beliefs, they have the potential to inform practices for most effectively communicating with and persuading religious and nonreligious individuals to change maladaptive behavior, even when the mode of discourse is unrelated to religious belief.
Yang, Yong; Liu, Yongzhong; Yu, Bo; Ding, Tian
2016-06-01
Volatile contaminants may migrate with carbon dioxide (CO2) injection or leakage in subsurface formations, which leads to the risk of the CO2 storage and the ecological environment. This study aims to develop an analytical model that could predict the contaminant migration process induced by CO2 storage. The analytical model with two moving boundaries is obtained through the simplification of the fully coupled model for the CO2-aqueous phase -stagnant phase displacement system. The analytical solutions are confirmed and assessed through the comparison with the numerical simulations of the fully coupled model. Then, some key variables in the analytical solutions, including the critical time, the locations of the dual moving boundaries and the advance velocity, are discussed to present the characteristics of contaminant migration in the multi-phase displacement system. The results show that these key variables are determined by four dimensionless numbers, Pe, RD, Sh and RF, which represent the effects of the convection, the dispersion, the interphase mass transfer and the retention factor of contaminant, respectively. The proposed analytical solutions could be used for tracking the migration of the injected CO2 and the contaminants in subsurface formations, and also provide an analytical tool for other solute transport in multi-phase displacement system. Copyright © 2016 Elsevier B.V. All rights reserved.
A Fuzzy-Based Decision Support Model for Selecting the Best Dialyser Flux in Haemodialysis.
Oztürk, Necla; Tozan, Hakan
2015-01-01
Decision making is an important procedure for every organization. The procedure is particularly challenging for complicated multi-criteria problems. Selection of dialyser flux is one of the decisions routinely made for haemodialysis treatment provided for chronic kidney failure patients. This study provides a decision support model for selecting the best dialyser flux between high-flux and low-flux dialyser alternatives. The preferences of decision makers were collected via a questionnaire. A total of 45 questionnaires filled by dialysis physicians and nephrologists were assessed. A hybrid fuzzy-based decision support software that enables the use of Analytic Hierarchy Process (AHP), Fuzzy Analytic Hierarchy Process (FAHP), Analytic Network Process (ANP), and Fuzzy Analytic Network Process (FANP) was used to evaluate the flux selection model. In conclusion, the results showed that a high-flux dialyser is the best. option for haemodialysis treatment.
Herzog, W; Binding, P
1993-11-01
It has been stated in the literature that static, nonlinear optimization approaches cannot predict coactivation of pairs of antagonistic muscles; however, numerical solutions of such approaches have predicted coactivation of pairs of one-joint and multijoint antagonists. Analytical support for either finding is not available in the literature for systems containing more than one degree of freedom. The purpose of this study was to investigate analytically the possibility of cocontraction of pairs of antagonistic muscles using a static nonlinear optimization approach for a multidegree-of-freedom, two-dimensional system. Analytical solutions were found using the Karush-Kuhn-Tucker conditions, which were necessary and sufficient for optimality in this problem. The results show that cocontraction of pairs of one-joint antagonistic muscles is not possible, whereas cocontraction of pairs of multijoint antagonists is. These findings suggest that cocontraction of pairs of antagonistic muscles may be an "efficient" way to accomplish many movement tasks.
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING INITIAL ...
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING INITIAL EXCAVATION. INL PHOTO NUMBER NRTS-54-10703. Unknown Photographer, 5/21/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Boyraz, Uǧur; Melek Kazezyılmaz-Alhan, Cevza
2017-04-01
Groundwater is a vital element of hydrologic cycle and the analytical & numerical solutions of different forms of groundwater flow equations play an important role in understanding the hydrological behavior of subsurface water. The interaction between groundwater and surface water bodies can be determined using these solutions. In this study, new hypothetical approaches are implemented to groundwater flow system in order to contribute to the studies on surface water/groundwater interactions. A time dependent problem is considered in a 2-dimensional stream-wetland-aquifer system. The sloped stream boundary is used to represent the interaction between stream and aquifer. The rest of the aquifer boundaries are assumed as no-flux boundary. In addition, a wetland is considered as a surface water body which lies over the whole aquifer. The effect of the interaction between the wetland and the aquifer is taken into account with a source/sink term in the groundwater flow equation and the interaction flow is calculated by using Darcy's approach. A semi-analytical solution is developed for the 2-dimensional groundwater flow equation in 5 steps. First, Laplace and Fourier cosine transforms are employed to obtain the general solution in Fourier and Laplace domain. Then, the initial and boundary conditions are applied to obtain the particular solution. Finally, inverse Fourier transform is carried out analytically and inverse Laplace transform is carried out numerically to obtain the final solution in space and time domain, respectively. In order to verify the semi-analytical solution, an explicit finite difference algorithm is developed and analytical and numerical solutions are compared for synthetic examples. The comparison of the analytical and numerical solutions shows that the analytical solution gives accurate results.
Regularity of Solutions of the Nonlinear Sigma Model with Gravitino
NASA Astrophysics Data System (ADS)
Jost, Jürgen; Keßler, Enno; Tolksdorf, Jürgen; Wu, Ruijun; Zhu, Miaomiao
2018-02-01
We propose a geometric setup to study analytic aspects of a variant of the super symmetric two-dimensional nonlinear sigma model. This functional extends the functional of Dirac-harmonic maps by gravitino fields. The system of Euler-Lagrange equations of the two-dimensional nonlinear sigma model with gravitino is calculated explicitly. The gravitino terms pose additional analytic difficulties to show smoothness of its weak solutions which are overcome using Rivière's regularity theory and Riesz potential theory.
Ellipsoidal Brownian self-driven particles in a magnetic field
NASA Astrophysics Data System (ADS)
Sandoval, Mario; Wai-Tong, Fan; Shun Pak, On
We study the two-dimensional Brownian dynamics of an ellipsoidal paramagnetic microswimmer moving at low Reynolds number and subject to a magnetic field. Its corresponding mean-square displacement showing the effect of particles's shape, activity, and magnetic field on the microswimmer's diffusion is analytically obtained. A comparison among analytical and computational results is also made and we obtain good agreement. Additionally, the effect of self-propulsion on the transition time from anisotropic to isotropic diffusion of the ellipse is also elucidated. CONACYT GRANT: CB 2014/237848.
Multi-analyte validation in heterogeneous solution by ELISA.
Lakshmipriya, Thangavel; Gopinath, Subash C B; Hashim, Uda; Murugaiyah, Vikneswaran
2017-12-01
Enzyme Linked Immunosorbent Assay (ELISA) is a standard assay that has been used widely to validate the presence of analyte in the solution. With the advancement of ELISA, different strategies have shown and became a suitable immunoassay for a wide range of analytes. Herein, we attempted to provide additional evidence with ELISA, to show its suitability for multi-analyte detection. To demonstrate, three clinically relevant targets have been chosen, which include 16kDa protein from Mycobacterium tuberculosis, human blood clotting Factor IXa and a tumour marker Squamous Cell Carcinoma antigen. Indeed, we adapted the routine steps from the conventional ELISA to validate the occurrence of analytes both in homogeneous and heterogeneous solutions. With the homogeneous and heterogeneous solutions, we could attain the sensitivity of 2, 8 and 1nM for the targets 16kDa protein, FIXa and SSC antigen, respectively. Further, the specific multi-analyte validations were evidenced with the similar sensitivities in the presence of human serum. ELISA assay in this study has proven its applicability for the genuine multiple target validation in the heterogeneous solution, can be followed for other target validations. Copyright © 2017 Elsevier B.V. All rights reserved.
A theoretical study on pure bending of hexagonal close-packed metal sheet
NASA Astrophysics Data System (ADS)
Mehrabi, Hamed; Yang, Chunhui
2018-05-01
Hexagonal close-packed (HCP) metals have quite different mechanical behaviours in comparison to conventional cubic metals such as steels and aluminum alloys [1, 2]. They exhibit a significant tension-compression asymmetry in initial yielding and subsequent plastic hardening. The reason for this unique behaviour can be attributed to their limited symmetric crystal structure, which leads to twining deformation [3-5]. This unique behaviour strongly influences sheet metal forming of such metals, especially for roll forming, in which the bending is dominant. Hence, it is crucial to represent constitutive relations of HCP metals for accurate estimation of bending moment-curvature behaviours. In this paper, an analytical model for asymmetric elastoplastic pure bending with an application of Cazacu-Barlat asymmetric yield function [6] is presented. This yield function considers the asymmetrical tension-compression behaviour of HCP metals by using second and third invariants of the stress deviator tensor and a specified constant, which can be expressed in terms of uniaxial yield stresses in tension and compression. As a case study, the analytical model is applied to predict the moment-curvature behaviours of AZ31B magnesium alloy sheets under uniaxial loading condition. Furthermore, the analytical model is implemented as a user-defined material through the UMAT interface in Abaqus [7, 8] for conducting pure bending simulations. The results show that the analytical model can reasonably capture the asymmetric tension-compression behaviour of the magnesium alloy. The predicted moment-curvature behaviour has good agreement with the experimental results. Furthermore, numerical results show a better accuracy by the application of the Cazacu-Barlat yield function than those using the von-Mises yield function, which are more conservative than analytical results.
European Multicenter Study on Analytical Performance of Veris HIV-1 Assay.
Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kalus, Ulrich; Lombardi, Alessandra; Marcos, Maria Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel W
2017-07-01
The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log 10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log 10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log 10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.). Copyright © 2017 American Society for Microbiology.
FAST TRACK COMMUNICATION: Uniqueness of static black holes without analyticity
NASA Astrophysics Data System (ADS)
Chruściel, Piotr T.; Galloway, Gregory J.
2010-08-01
We show that the hypothesis of analyticity in the uniqueness theory of vacuum, or electrovacuum, static black holes is not needed. More generally, we show that prehorizons covering a closed set cannot occur in well-behaved domains of outer communications.
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING PLACEMENT ...
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING PLACEMENT OF PIERS. INL PHOTO NUMBER NRTS-54-11716. Unknown Photographer, 8/20/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Mechanical Properties of Additively Manufactured Thick Honeycombs
Hedayati, Reza; Sadighi, Mojtaba; Mohammadi Aghdam, Mohammad; Zadpoor, Amir Abbas
2016-01-01
Honeycombs resemble the structure of a number of natural and biological materials such as cancellous bone, wood, and cork. Thick honeycomb could be also used for energy absorption applications. Moreover, studying the mechanical behavior of honeycombs under in-plane loading could help understanding the mechanical behavior of more complex 3D tessellated structures such as porous biomaterials. In this paper, we study the mechanical behavior of thick honeycombs made using additive manufacturing techniques that allow for fabrication of honeycombs with arbitrary and precisely controlled thickness. Thick honeycombs with different wall thicknesses were produced from polylactic acid (PLA) using fused deposition modelling, i.e., an additive manufacturing technique. The samples were mechanically tested in-plane under compression to determine their mechanical properties. We also obtained exact analytical solutions for the stiffness matrix of thick hexagonal honeycombs using both Euler-Bernoulli and Timoshenko beam theories. The stiffness matrix was then used to derive analytical relationships that describe the elastic modulus, yield stress, and Poisson’s ratio of thick honeycombs. Finite element models were also built for computational analysis of the mechanical behavior of thick honeycombs under compression. The mechanical properties obtained using our analytical relationships were compared with experimental observations and computational results as well as with analytical solutions available in the literature. It was found that the analytical solutions presented here are in good agreement with experimental and computational results even for very thick honeycombs, whereas the analytical solutions available in the literature show a large deviation from experimental observation, computational results, and our analytical solutions. PMID:28773735
Single-Cell Detection of Secreted Aβ and sAPPα from Human IPSC-Derived Neurons and Astrocytes.
Liao, Mei-Chen; Muratore, Christina R; Gierahn, Todd M; Sullivan, Sarah E; Srikanth, Priya; De Jager, Philip L; Love, J Christopher; Young-Pearse, Tracy L
2016-02-03
Secreted factors play a central role in normal and pathological processes in every tissue in the body. The brain is composed of a highly complex milieu of different cell types and few methods exist that can identify which individual cells in a complex mixture are secreting specific analytes. By identifying which cells are responsible, we can better understand neural physiology and pathophysiology, more readily identify the underlying pathways responsible for analyte production, and ultimately use this information to guide the development of novel therapeutic strategies that target the cell types of relevance. We present here a method for detecting analytes secreted from single human induced pluripotent stem cell (iPSC)-derived neural cells and have applied the method to measure amyloid β (Aβ) and soluble amyloid precursor protein-alpha (sAPPα), analytes central to Alzheimer's disease pathogenesis. Through these studies, we have uncovered the dynamic range of secretion profiles of these analytes from single iPSC-derived neuronal and glial cells and have molecularly characterized subpopulations of these cells through immunostaining and gene expression analyses. In examining Aβ and sAPPα secretion from single cells, we were able to identify previously unappreciated complexities in the biology of APP cleavage that could not otherwise have been found by studying averaged responses over pools of cells. This technique can be readily adapted to the detection of other analytes secreted by neural cells, which would have the potential to open new perspectives into human CNS development and dysfunction. We have established a technology that, for the first time, detects secreted analytes from single human neurons and astrocytes. We examine secretion of the Alzheimer's disease-relevant factors amyloid β (Aβ) and soluble amyloid precursor protein-alpha (sAPPα) and present novel findings that could not have been observed without a single-cell analytical platform. First, we identify a previously unappreciated subpopulation that secretes high levels of Aβ in the absence of detectable sAPPα. Further, we show that multiple cell types secrete high levels of Aβ and sAPPα, but cells expressing GABAergic neuronal markers are overrepresented. Finally, we show that astrocytes are competent to secrete high levels of Aβ and therefore may be a significant contributor to Aβ accumulation in the brain. Copyright © 2016 the authors 0270-6474/16/361730-17$15.00/0.
Lu, Liang-Xing; Wang, Ying-Min; Srinivasan, Bharathi Madurai; Asbahi, Mohamed; Yang, Joel K. W.; Zhang, Yong-Wei
2016-01-01
We perform systematic two-dimensional energetic analysis to study the stability of various nanostructures formed by dewetting solid films deposited on patterned substrates. Our analytical results show that by controlling system parameters such as the substrate surface pattern, film thickness and wetting angle, a variety of equilibrium nanostructures can be obtained. Phase diagrams are presented to show the complex relations between these system parameters and various nanostructure morphologies. We further carry out both phase field simulations and dewetting experiments to validate the analytically derived phase diagrams. Good agreements between the results from our energetic analyses and those from our phase field simulations and experiments verify our analysis. Hence, the phase diagrams presented here provide guidelines for using solid-state dewetting as a tool to achieve various nanostructures. PMID:27580943
Galhiane, Mário S; Rissato, Sandra R; Chierice, Gilberto O; Almeida, Marcos V; Silva, Letícia C
2006-09-15
This work has been developed using a sylvestral fruit tree, native to the Brazilian forest, the Eugenia uniflora L., one of the Mirtaceae family. The main goal of the analytical study was focused on extraction methods themselves. The method development pointed to the Clevenger extraction as the best yield in relation to SFE and Soxhlet. The SFE method presented a good yield but showed a big amount of components in the final extract, demonstrating low selectivity. The essential oil extracted was analyzed by GC/FID showing a large range of polarity and boiling point compounds, where linalool, a widely used compound, was identified. Furthermore, an analytical solid phase extraction method was used to clean it up and obtain separated classes of compounds that were fractionated and studied by GC/FID and GC/MS.
DISTRIBUTION SYSTEMS AS RESERVOIRS AND REACTORS FOR INORGANIC CONTAMINANTS
This paper provides a review of numerous drinking water and geochemical investigations and recent studies of pipe deposits and water treatment materials. This analysis shows that there is growing evidence from analogous natural water systems and some analytical studies that many ...
NASA Astrophysics Data System (ADS)
Krasichkov, Alexander S.; Grigoriev, Eugene B.; Bogachev, Mikhail I.; Nifontov, Eugene M.
2015-10-01
We suggest an analytical approach to the adaptive thresholding in a shape anomaly detection problem. We find an analytical expression for the distribution of the cosine similarity score between a reference shape and an observational shape hindered by strong measurement noise that depends solely on the noise level and is independent of the particular shape analyzed. The analytical treatment is also confirmed by computer simulations and shows nearly perfect agreement. Using this analytical solution, we suggest an improved shape anomaly detection approach based on adaptive thresholding. We validate the noise robustness of our approach using typical shapes of normal and pathological electrocardiogram cycles hindered by additive white noise. We show explicitly that under high noise levels our approach considerably outperforms the conventional tactic that does not take into account variations in the noise level.
Olivero, Sergio J Pérez; Trujillo, Juan P Pérez
2011-06-24
A new analytical method for the determination of nine short-chain fatty acids (acetic, propionic, isobutyric, butyric, isovaleric, 2-methylbutyric, hexanoic, octanoic and decanoic acids) in wines using the automated HS/SPME-GC-ITMS technique was developed and optimised. Five different SPME fibers were tested and the influence of different factors such as temperature and time of extraction, temperature and time of desorption, pH, strength ionic, tannins, anthocyans, SO(2), sugar and ethanol content were studied and optimised using model solutions. Some analytes showed matrix effect so a study of recoveries was performed. The proposed HS/SPME-GC-ITMS method, that covers the concentration range of the different analytes in wines, showed wide linear ranges, values of repeatability and reproducibility lower than 4.0% of RSD and detection limits between 3 and 257 μgL(-1), lower than the olfactory thresholds. The optimised method is a suitable technique for the quantitative analysis of short-chain fatty acids from the aliphatic series in real samples of white, rose and red wines. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Y. B.; Zhu, X. W.; Dai, H. H.
2016-08-01
Though widely used in modelling nano- and micro- structures, Eringen's differential model shows some inconsistencies and recent study has demonstrated its differences between the integral model, which then implies the necessity of using the latter model. In this paper, an analytical study is taken to analyze static bending of nonlocal Euler-Bernoulli beams using Eringen's two-phase local/nonlocal model. Firstly, a reduction method is proved rigorously, with which the integral equation in consideration can be reduced to a differential equation with mixed boundary value conditions. Then, the static bending problem is formulated and four types of boundary conditions with various loadings are considered. By solving the corresponding differential equations, exact solutions are obtained explicitly in all of the cases, especially for the paradoxical cantilever beam problem. Finally, asymptotic analysis of the exact solutions reveals clearly that, unlike the differential model, the integral model adopted herein has a consistent softening effect. Comparisons are also made with existing analytical and numerical results, which further shows the advantages of the analytical results obtained. Additionally, it seems that the once controversial nonlocal bar problem in the literature is well resolved by the reduction method.
Galy, Bertrand; Lan, André
2018-03-01
Among the many occupational risks construction workers encounter every day falling from a height is the most dangerous. The objective of this article is to propose a simple analytical design method for horizontal lifelines (HLLs) that considers anchorage flexibility. The article presents a short review of the standards and regulations/acts/codes concerning HLLs in Canada the USA and Europe. A static analytical approach is proposed considering anchorage flexibility. The analytical results are compared with a series of 42 dynamic fall tests and a SAP2000 numerical model. The experimental results show that the analytical method is a little conservative and overestimates the line tension in most cases with a maximum of 17%. The static SAP2000 results show a maximum 2.1% difference with the analytical method. The analytical method is accurate enough to safely design HLLs and quick design abaci are provided to allow the engineer to make quick on-site verification if needed.
Bhushan, Ravi; Sen, Arijit
2017-04-01
Very few Indian studies exist on evaluation of pre-analytical variables affecting "Prothrombin Time" the commonest coagulation assay performed. The study was performed in an Indian tertiary care setting with an aim to assess quantitatively the prevalence of pre-analytical variables and their effects on the results (patient safety), for Prothrombin time test. The study also evaluated their effects on the result and whether intervention, did correct the results. The firstly evaluated the prevalence for various pre-analytical variables detected in samples sent for Prothrombin Time testing. These samples with the detected variables wherever possible were tested and result noted. The samples from the same patients were repeated and retested ensuring that no pre-analytical variable is present. The results were again noted to check for difference the intervention produced. The study evaluated 9989 samples received for PT/INR over a period of 18 months. The prevalence of different pre-analytical variables was found to be 862 (8.63%). The proportion of various pre-analytical variables detected were haemolysed samples 515 (5.16%), over filled vacutainers 62 (0.62%), under filled vacutainers 39 (0.39%), low values 205 (2.05%), clotted samples 11 (0.11%), wrong labeling 4 (0.04%), wrong vacutainer use 2 (0.02%), chylous samples 7 (0.07%) and samples with more than one variable 17 (0.17%). The comparison of percentage of samples showing errors were noted for the first variables since they could be tested with and without the variable in place. The reduction in error percentage was 91.5%, 69.2%, 81.5% and 95.4% post intervention for haemolysed, overfilled, under filled and samples collected with excess pressure at phlebotomy respectively. Correcting the variables did reduce the error percentage to a great extent in these four variables and hence the variables are found to affect "Prothrombin Time" testing and can hamper patient safety.
CONSTRUCTION PROGRESS PHOTO REMOTE ANALYTICAL FACILITY (CPP627) SHOWING EMPLACEMENT OF ...
CONSTRUCTION PROGRESS PHOTO REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING EMPLACEMENT OF ROOF SLABS. INL PHOTO NUMBER NRTS-54-13463. R.G. Larsen, Photographer, 12/20/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Ivanova, V.; Surleva, A.; Koleva, B.
2018-06-01
An ion chromatographic method for determination of fluoride, chloride, nitrate and sulphate in untreated and treated drinking waters was described. An automated 850 IC Professional, Metrohm system equipped with conductivity detector and Metrosep A Supp 7-250 (250 x 4 mm) column was used. The validation of the method was performed for simultaneous determination of all studied analytes and the results have showed that the validated method fits the requirements of the current water legislation. The main analytical characteristics were estimated for each of studied analytes: limits of detection, limits of quantification, working and linear ranges, repeatability and intermediate precision, recovery. The trueness of the method was estimated by analysis of certified reference material for soft drinking water. Recovery test was performed on spiked drinking water samples. An uncertainty was estimated. The method was applied for analysis of drinking waters before and after chlorination.
A Widely Applicable Silver Sol for TLC Detection with Rich and Stable SERS Features.
Zhu, Qingxia; Li, Hao; Lu, Feng; Chai, Yifeng; Yuan, Yongfang
2016-12-01
Thin-layer chromatography (TLC) coupled with surface-enhanced Raman spectroscopy (SERS) has gained tremendous popularity in the study of various complex systems. However, the detection of hydrophobic analytes is difficult, and the specificity still needs to be improved. In this study, a SERS-active non-aqueous silver sol which could activate the analytes to produce rich and stable spectral features was rapidly synthesized. Then, the optimized silver nanoparticles (AgNPs)-DMF sol was employed for TLC-SERS detection of hydrophobic (and also hydrophilic) analytes. SERS performance of this sol was superior to that of traditional Lee-Meisel AgNPs due to its high specificity, acceptable stability, and wide applicability. The non-aqueous AgNPs would be suitable for the TLC-SERS method, which shows great promise for applications in food safety assurance, environmental monitoring, medical diagnoses, and many other fields.
A Widely Applicable Silver Sol for TLC Detection with Rich and Stable SERS Features
NASA Astrophysics Data System (ADS)
Zhu, Qingxia; Li, Hao; Lu, Feng; Chai, Yifeng; Yuan, Yongfang
2016-04-01
Thin-layer chromatography (TLC) coupled with surface-enhanced Raman spectroscopy (SERS) has gained tremendous popularity in the study of various complex systems. However, the detection of hydrophobic analytes is difficult, and the specificity still needs to be improved. In this study, a SERS-active non-aqueous silver sol which could activate the analytes to produce rich and stable spectral features was rapidly synthesized. Then, the optimized silver nanoparticles (AgNPs)-DMF sol was employed for TLC-SERS detection of hydrophobic (and also hydrophilic) analytes. SERS performance of this sol was superior to that of traditional Lee-Meisel AgNPs due to its high specificity, acceptable stability, and wide applicability. The non-aqueous AgNPs would be suitable for the TLC-SERS method, which shows great promise for applications in food safety assurance, environmental monitoring, medical diagnoses, and many other fields.
Analytical investigation of the faster-is-slower effect with a simplified phenomenological model
NASA Astrophysics Data System (ADS)
Suzuno, K.; Tomoeda, A.; Ueyama, D.
2013-11-01
We investigate the mechanism of the phenomenon called the “faster-is-slower”effect in pedestrian flow studies analytically with a simplified phenomenological model. It is well known that the flow rate is maximized at a certain strength of the driving force in simulations using the social force model when we consider the discharge of self-driven particles through a bottleneck. In this study, we propose a phenomenological and analytical model based on a mechanics-based modeling to reveal the mechanism of the phenomenon. We show that our reduced system, with only a few degrees of freedom, still has similar properties to the original many-particle system and that the effect comes from the competition between the driving force and the nonlinear friction from the model. Moreover, we predict the parameter dependences on the effect from our model qualitatively, and they are confirmed numerically by using the social force model.
Analytical study on the self-healing property of Bessel beam
NASA Astrophysics Data System (ADS)
Chu, X.
2012-10-01
With the help of Babinet principle, an analytical expression for the self-healing of Bessel beam is derived by using the Gaussian absorption function to describe the obstacle. Based on the analytical expression, the self-healing properties of Bessel beam are studied. It shows that Bessel beam has the ability to reconstruct its beam shape disturbed by an obstacle. However, during the self-healing process, not only the intensity of the beam behind the obstacle but also the other part will be affected by the obstruction. Meanwhile, the highlight spot, which intensity is larger than that without the obstacle will appear, and the size and strength of the highlight spot is determined by the size of the obstacle. From the change of Poynting vector and Babinet principle, the physical interpretations for the self-healing ability, the effects of the obstruction on the other part and the appearance of highlight spot are given.
Study of the effect of loop inductance on the RF transmission line to cavity coupling coefficient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lal, Shankar, E-mail: shankar@rrcat.gov.in; Pant, K. K.
2016-08-15
Coupling of RF power is an important aspect in the design and development of RF accelerating structures. RF power coupling employing coupler loops has the advantage of tunability of β, the transmission line to cavity coupling coefficient. Analytical expressions available in literature for determination of size of the coupler loop using Faraday’s law of induction show reasonably good agreement with experimentally measured values of β below critical coupling (β ≤ 1) but show large deviation with experimentally measured values and predictions by simulations for higher values of β. In actual accelerator application, many RF cavities need to be over-coupled withmore » β > 1 for reasons of beam loading compensation, reduction of cavity filling time, etc. This paper discusses a modified analytical formulation by including the effect of loop inductance in the determination of loop size for any desired coupling coefficient. The analytical formulation shows good agreement with 3D simulations and with experimentally measured values. It has been successfully qualified by the design and development of power coupler loops for two 476 MHz pre-buncher RF cavities, which have successfully been conditioned at rated power levels using these coupler loops.« less
Study of the effect of loop inductance on the RF transmission line to cavity coupling coefficient
NASA Astrophysics Data System (ADS)
Lal, Shankar; Pant, K. K.
2016-08-01
Coupling of RF power is an important aspect in the design and development of RF accelerating structures. RF power coupling employing coupler loops has the advantage of tunability of β, the transmission line to cavity coupling coefficient. Analytical expressions available in literature for determination of size of the coupler loop using Faraday's law of induction show reasonably good agreement with experimentally measured values of β below critical coupling (β ≤ 1) but show large deviation with experimentally measured values and predictions by simulations for higher values of β. In actual accelerator application, many RF cavities need to be over-coupled with β > 1 for reasons of beam loading compensation, reduction of cavity filling time, etc. This paper discusses a modified analytical formulation by including the effect of loop inductance in the determination of loop size for any desired coupling coefficient. The analytical formulation shows good agreement with 3D simulations and with experimentally measured values. It has been successfully qualified by the design and development of power coupler loops for two 476 MHz pre-buncher RF cavities, which have successfully been conditioned at rated power levels using these coupler loops.
Learning English through Social Interaction: The Case of "Big Brother 2006," Finland
ERIC Educational Resources Information Center
Kaanta, Leila; Jauni, Heidi; Leppanen, Sirpa; Peuronen, Saija; Paakkinen, Terhi
2013-01-01
In line with recent Conversation Analytic work on language learning as situated practice, this article investigates how interactants can create language learning opportunities for themselves and others in and through social interaction. The study shows how the participants of "Big Brother Finland," a reality TV show, whose main…
Koscho, Michael E; Grubbs, Robert H; Lewis, Nathan S
2002-03-15
Arrays of vapor detectors have been formed through addition of varying mass fractions of the plasticizer diethylene glycol dibenzoate to carbon black-polymer composites of poly(vinyl acetate) (PVAc) or of poly(N-vinylpyrrolidone). Addition of plasticizer in 5% mass fraction increments produced 20 compositionally different detectors from each polymer composite. Differences in vapor sorption and permeability that effected changes in the dc electrical resistance response of these compositionally different detectors allowed identification and classification of various test analytes using standard chemometric methods. Glass transition temperatures, Tg, were measured using differential scanning calorimetry for plasticized polymers having a mass fraction of 0, 0.10, 0.20, 0.30, 0.40, or 0.50 of plasticizer in the composite. The plasticized PVAc composites with Tg < 25 degrees C showed rapid responses at room temperature to all of the test analyte vapors studied in this work, whereas composites with Tg > 25 degrees C showed response times that were highly dependent on the polymer/analyte combination. These composites showed a discontinuity in the temperature dependence of their resistance, and this discontinuity provided a simple method for determining the Tg of the composite and for determining the temperature or plasticizer mass fraction above which rapid resistance responses could be obtained for all members of the test set of analyte vapors. The plasticization approach provides a method for achieving rapid detector response times as well as for producing a large number of chemically different vapor detectors from a limited number of initial chemical feedstocks.
Theoretical study of a molecular turbine.
Perez-Carrasco, R; Sancho, J M
2013-10-01
We present an analytic and stochastic simulation study of a molecular engine working with a flux of particles as a turbine. We focus on the physical observables of velocity, flux, power, and efficiency. The control parameters are the external conservative force and the particle densities. We revise a simpler previous study by using a more realistic model containing multiple equidistant vanes complemented by stochastic simulations of the particles and the turbine. Here we show that the effect of the thermal fluctuations into the flux and the efficiency of these nanometric devices are relevant to the working scale of the system. The stochastic simulations of the Brownian motion of the particles and turbine support the simplified analytical calculations performed.
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi; Leyland, Jane
1991-01-01
The effects of open loop higher harmonic control (HHC) on rotor hub loads, performance, and push rod loads of a Sikorsky S-76 helicopter rotor at high airspeeds (up to 200 knots) and moderate lift (10,000 lbs) were studied analytically. The analysis was performed as part of a wind tunnel pre-test prediction and preparation procedure, as well as to provide analytical results for post-test correlation efforts. The test associated with this study is to be concluded in the 40- by 80-Foot Wind Tunnel of the National Full-Scale Aerodynamics Complex (NFAC) at the NASA Ames Research Center. The results from this analytical study show that benefits from HHC can be achieved at high airspeeds. These results clear the way for conducting (with the requirement of safe pushrod loads) an open loop HHC test a high airspeeds in the 40- by 80-Foot Wind Tunnel using an S-76 rotor as the test article.
Sagi-Schwartz, Abraham; van IJzendoorn, Marinus H; Bakermans-Kranenburg, Marian J
2008-06-01
In a series of meta-analyses with the second generation of Holocaust survivors, no evidence for secondary traumatization was found (Van IJzendoorn, Bakermans-Kranenburg, & Sagi-Schwartz, 2003). With regard to third generation traumatization, various reports suggest the presence of intergenerational transmission of trauma. Some scholars argue that intergenerational transmission of trauma might skip a generation. Therefore, we focus in this study on the transmission of trauma to the third generation offspring (the grandchildren) of the first generation's traumatic Holocaust experiences (referred to as "tertiary traumatization"), and we present a narrative review of the pertinent studies. Meta-analytic results of 13 non-clinical samples involving 1012 participants showed no evidence for tertiary traumatization in Holocaust survivor families. Our previous meta-analytic study on secondary traumatization and the present one on third generation's psychological consequences of the Holocaust indicate a remarkable resilience of profoundly traumatized survivors in their (grand-)parental roles.
NASA Technical Reports Server (NTRS)
Purdy, K. R.; Ventrice, M. B.; Fang, J.
1972-01-01
Analytical and experimental studies were initiated to determine if the response of a constant temperature hot wire anemometer to acoustic oscillations could serve as an analog to the response of the drop vaporization burning rate process to acoustic oscillations, and, perhaps, also as an analog to any Reynolds number dependent process. The motivation behind this study was a recent analytical study which showed that distorted acoustic oscillations could amplify the open-loop response of vaporization limited combustion. This type of amplification may be the cause of unstable combustion in liquid propellant rocket engines. The analytical results obtained for the constant temperature anemometer are similar in nature to those previously obtained for vaporization limited combustion and indicate that the response is dependent on the amount and type of distortion as well as other factors, such as sound pressure level, Mach number and hot wire temperature. Preliminary results indicate qualitative agreement between theory and experiment.
NASA Technical Reports Server (NTRS)
Walter, T. J.
1978-01-01
Vibration characteristics for overhauled T53 engines, including rejection rate, principal sources of vibration, and normal procedures taken by the overhaul center to reduce engine vibration are summarized. Analytical and experimental data were compared to determine the engine's dynamic response to unbalance forces with results showing that the engine operates through bending critical speeds. Present rigid rotor balancing techniques are incapable of compensating for the flexible rotor unbalance. A comparison of typical test cell and aircraft vibration levels disclosed significant differences in the engine's dynamic response. A probable spline shift phenomenon was uncovered and investigated. Action items to control costs and reduce vibration levels were identified from analytical and experimental studies.
Redígolo, M M; Sato, I M; Metairon, S; Zamboni, C B
2016-04-01
Several diseases can be diagnosed observing the variation of specific elements concentration in body fluids. In this study the concentration of inorganic elements in blood samples of dystrophic (Dmd(mdx)/J) and C57BL/6J (control group) mice strain were determined. The results obtained from Energy Dispersive X-ray Fluorescence (EDXRF) were compared with Neutron Activation Analysis (NAA) technique. Both analytical techniques showed to be appropriate and complementary offering a new contribution for veterinary medicine as well as detailed knowledge of this pathology. Copyright © 2016 Elsevier Ltd. All rights reserved.
Entanglement entropy in the long-range Kitaev chain
NASA Astrophysics Data System (ADS)
Ares, Filiberto; Esteve, José G.; Falceto, Fernando; de Queiroz, Amilcar R.
2018-06-01
In this paper we complete the study on the asymptotic behavior of the entanglement entropy for Kitaev chains with long-range pairing. We discover that when the couplings decay with the distance with a critical exponent new properties for the asymptotic growth of the entropy appear. The coefficient of the leading term is not universal any more and the connection with conformal field theories is lost. We perform a numerical and analytical approach to the problem showing a perfect agreement. In order to carry out the analytical study, a technique for computing the asymptotic behavior of block Toeplitz determinants with discontinuous symbols has been developed.
Timing variation in an analytically solvable chaotic system
NASA Astrophysics Data System (ADS)
Blakely, J. N.; Milosavljevic, M. S.; Corron, N. J.
2017-02-01
We present analytic solutions for a chaotic dynamical system that do not have the regular timing characteristic of recently reported solvable chaotic systems. The dynamical system can be viewed as a first order filter with binary feedback. The feedback state may be switched only at instants defined by an external clock signal. Generalizing from a period one clock, we show analytic solutions for period two and higher period clocks. We show that even when the clock 'ticks' randomly the chaotic system has an analytic solution. These solutions can be visualized in a stroboscopic map whose complexity increases with the complexity of the clock. We provide both analytic results as well as experimental data from an electronic circuit implementation of the system. Our findings bridge the gap between the irregular timing of well known chaotic systems such as Lorenz and Rossler and the well regulated oscillations of recently reported solvable chaotic systems.
Solà-Vázquez, Auristela; Lara-Gonzalo, Azucena; Costa-Fernández, José M; Pereiro, Rosario; Sanz-Medel, Alfredo
2010-05-01
A tuneable microsecond pulsed direct current glow discharge (GD)-time-of-flight mass spectrometer MS(TOF) developed in our laboratory was coupled to a gas chromatograph (GC) to obtain sequential collection of the mass spectra, at different temporal regimes occurring in the GD pulses, during elution of the analytes. The capabilities of this set-up were explored using a mixture of volatile organic compounds of environmental concern: BrClCH, Cl(3)CH, Cl(4)C, BrCl(2)CH, Br(2)ClCH, Br(3)CH. The experimental parameters of the GC-pulsed GD-MS(TOF) prototype were optimized in order to separate appropriately and analyze the six selected organic compounds, and two GC carrier gases, helium and nitrogen, were evaluated. Mass spectra for all analytes were obtained in the prepeak, plateau and afterpeak temporal regimes of the pulsed GD. Results showed that helium offered the best elemental sensitivity, while nitrogen provided higher signal intensities for fragments and molecular peaks. The analytical performance characteristics were also worked out for each analyte. Absolute detection limits obtained were in the order of ng. In a second step, headspace solid phase microextraction (HS SPME), as sample preparation and preconcentration technique, was evaluated for the quantification of the compounds under study, in order to achieve the required analytical sensitivity for trihalomethanes European Union (EU) environmental legislation. The analytical figures of merit obtained using the proposed methodology showed rather good detection limits (between 2 and 13 microg L(-1) depending on the analyte). In fact, the developed methodology met the EU legislation requirements (the maximum level permitted in tap water for the "total trihalomethanes" is set at 100 microg L(-1)). Real analysis of drinking water and river water were successfully carried out. To our knowledge this is the first application of GC-pulsed GD-MS(TOF) for the analysis of real samples. Its ability to provide elemental, fragments and molecular information of the organic compounds is demonstrated.
Lou, Xianwen; van Dongen, Joost L J; Milroy, Lech-Gustav; Meijer, E W
2016-12-30
Ionization in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a very complicated process. It has been reported that quaternary ammonium salts show extremely strong matrix and analyte suppression effects which cannot satisfactorily be explained by charge transfer reactions. Further investigation of the reasons causing these effects can be useful to improve our understanding of the MALDI process. The dried-droplet and modified thin-layer methods were used as sample preparation methods. In the dried-droplet method, analytes were co-crystallized with matrix, whereas in the modified thin-layer method analytes were deposited on the surface of matrix crystals. Model compounds, tetrabutylammonium iodide ([N(Bu) 4 ]I), cesium iodide (CsI), trihexylamine (THA) and polyethylene glycol 600 (PEG 600), were selected as the test analytes given their ability to generate exclusively pre-formed ions, protonated ions and metal ion adducts respectively in MALDI. The strong matrix suppression effect (MSE) observed using the dried-droplet method might disappear using the modified thin-layer method, which suggests that the incorporation of analytes in matrix crystals contributes to the MSE. By depositing analytes on the matrix surface instead of incorporating in the matrix crystals, the competition for evaporation/ionization from charged matrix/analyte clusters could be weakened resulting in reduced MSE. Further supporting evidence for this inference was found by studying the analyte suppression effect using the same two sample deposition methods. By comparing differences between the mass spectra obtained via the two sample preparation methods, we present evidence suggesting that the generation of gas-phase ions from charged matrix/analyte clusters may induce significant suppression of matrix and analyte ions. The results suggest that the generation of gas-phase ions from charged matrix/analyte clusters is an important ionization step in MALDI-MS. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Analysis of structural dynamic data from Skylab. Volume 2: Skylab analytical and test model data
NASA Technical Reports Server (NTRS)
Demchak, L.; Harcrow, H.
1976-01-01
The orbital configuration test modal data, analytical test correlation modal data, and analytical flight configuration modal data are presented. Tables showing the generalized mass contributions (GMCs) for each of the thirty tests modes are given along with the two dimensional mode shape plots and tables of GMCs for the test correlated analytical modes. The two dimensional mode shape plots for the analytical modes and uncoupled and coupled modes of the orbital flight configuration at three development phases of the model are included.
Lubricant Evaluation and Performance 2
1992-01-01
IDENTIFICATION OF SAMPLES USED IN ANALYTICAL FERROGRAPHY STUDY INCLUDING DESCRIPTION OF FERROGRAM DEBRIS 223 89. ANALYTICAL FERROGRAPH DATA FOR DOD-L-85734(AS...testing under various test parameters for determining effects on lubricant stability. Ferrography of the wear test samples showed a change in type of... ATLA i -- 0 A~ LAO0 O0 ui C.6j 0 0 -0 VI. CD 0-. Li C . LiC: a.- CD C). > C) : 132 L Y = 1.04X - 1.60 (r = 0.99997) 0 Y = 1.03X - 1.08 (r = 0.99999) 600
NASA Technical Reports Server (NTRS)
Prust, H. W., Jr.
1972-01-01
Demonstration that the change in output of a cooled turbine blade row relative to the specific output of the uncooled blade row can be positive, negative, or zero, depending on the velocity, injection location, injection angle, and temperature of the coolant. Comparisons between the analytical results and experimental results for four different cases of coolant discharge, all at a coolant temperature ratio of unity, show good agreement for three cases, and rather poor agreement for the other.
Evolution of microbiological analytical methods for dairy industry needs
Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence
2014-01-01
Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry’s needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards. PMID:24570675
Kellett, Stephen; Simmonds-Buckley, Mel; Totterdell, Peter
2017-08-18
The evidence base for treatment of hypersexuality disorder (HD) has few studies with appropriate methodological rigor. This study therefore conducted a single case experiment of cognitive analytic therapy (CAT) for HD using an A/B design with extended follow-up. Cruising, pornography usage, masturbation frequency and associated cognitions and emotions were measured daily in a 231-day time series. Following a three-week assessment baseline (A: 21 days), treatment was delivered via outpatient sessions (B: 147 days), with the follow-up period lasting 63 days. Results show that cruising and pornography usage extinguished. The total sexual outlet score no longer met caseness, and the primary nomothetic hypersexuality outcome measure met recovery criteria. Reduced pornography consumption was mediated by reduced obsessionality and greater interpersonal connectivity. The utility of the CAT model for intimacy problems shows promise. Directions for future HD outcome research are also provided.
Finite element modeling of mitral leaflet tissue using a layered shell approximation
Ratcliffe, Mark B.; Guccione, Julius M.
2012-01-01
The current study presents a finite element model of mitral leaflet tissue, which incorporates the anisotropic material response and approximates the layered structure. First, continuum mechanics and the theory of layered composites are used to develop an analytical representation of membrane stress in the leaflet material. This is done with an existing anisotropic constitutive law from literature. Then, the concept is implemented in a finite element (FE) model by overlapping and merging two layers of transversely isotropic membrane elements in LS-DYNA, which homogenizes the response. The FE model is then used to simulate various biaxial extension tests and out-of-plane pressure loading. Both the analytical and FE model show good agreement with experimental biaxial extension data, and show good mutual agreement. This confirms that the layered composite approximation presented in the current study is able to capture the exponential stiffening seen in both the circumferential and radial directions of mitral leaflets. PMID:22971896
Evolution of microbiological analytical methods for dairy industry needs.
Sohier, Danièle; Pavan, Sonia; Riou, Armelle; Combrisson, Jérôme; Postollec, Florence
2014-01-01
Traditionally, culture-based methods have been used to enumerate microbial populations in dairy products. Recent developments in molecular methods now enable faster and more sensitive analyses than classical microbiology procedures. These molecular tools allow a detailed characterization of cell physiological states and bacterial fitness and thus, offer new perspectives to integration of microbial physiology monitoring to improve industrial processes. This review summarizes the methods described to enumerate and characterize physiological states of technological microbiota in dairy products, and discusses the current deficiencies in relation to the industry's needs. Recent studies show that Polymerase chain reaction-based methods can successfully be applied to quantify fermenting microbes and probiotics in dairy products. Flow cytometry and omics technologies also show interesting analytical potentialities. However, they still suffer from a lack of validation and standardization for quality control analyses, as reflected by the absence of performance studies and official international standards.
Miron-Spektor, Ella; Efrat-Treister, Dorit; Rafaeli, Anat; Schwarz-Cohen, Orit
2011-09-01
The authors examine whether and how observing anger influences thinking processes and problem-solving ability. In 3 studies, the authors show that participants who listened to an angry customer were more successful in solving analytic problems, but less successful in solving creative problems compared with participants who listened to an emotionally neutral customer. In Studies 2 and 3, the authors further show that observing anger communicated through sarcasm enhances complex thinking and solving of creative problems. Prevention orientation is argued to be the latent variable that mediated the effect of observing anger on complex thinking. The present findings help reconcile inconsistent findings in previous research, promote theory about the effects of observing anger and sarcasm, and contribute to understanding the effects of anger in the workplace. PsycINFO Database Record (c) 2011 APA, all rights reserved
Analytical study of the reflection and transmission coefficient of the submarine interface
NASA Astrophysics Data System (ADS)
Zhang, Guangli; Hao, Chongtao; Yao, Chen
2018-05-01
The analytical study of the reflection and transmission coefficient of the seafloor interface is essential for the characterization of the ocean bottom in marine seismic exploration. Based on the boundary conditions of the seafloor interface, the analytical expression of the reflection and transmission coefficient at the submarine interface is derived in this study by using the steady-state wave solution of the elastic wave in a homogeneous, isotropic medium. With this analytical expression, the characteristics of the reflection and transmission coefficient at the submarine interface are analysed and discussed using critical angles. The results show that the change in the reflection and transmission coefficient with the incidence angle presents a "segmented" characteristic, in which the critical angle is the dividing point. The amplitude value and phase angle of the coefficient at the submarine interface change dramatically at the critical angle, which is related to the P- and S-wave velocities in the seabed layer. Compared with the stiff seabed, the soft seabed has a larger P-wave critical angle and an absence of the converted S-wave critical angle, owing to the low P- and S-wave velocities in the solid seabed layer. By analysing and discussing the special changes that occur in the coefficient values at the critical angle, the reflection and transmission characteristics of the different incident angles are obtained. Synthetic models of both stiff and soft seafloors are provided in this study to verify the analytical results. Finally, we compared our synthetic results with real data from the Gulf of Mexico, which enabled the validation of our conclusions.
Pulverman, Carey S; Hixon, J Gregory; Meston, Cindy M
2015-10-01
Based on analytic techniques that collapse data into a single average value, it has been reported that women lack category specificity and show genital sexual arousal to a large range of sexual stimuli including those that both match and do not match their self-reported sexual interests. These findings may be a methodological artifact of the way in which data are analyzed. This study examined whether using an analytic technique that models data over time would yield different results. Across two studies, heterosexual (N = 19) and lesbian (N = 14) women viewed erotic films featuring heterosexual, lesbian, and gay male couples, respectively, as their physiological sexual arousal was assessed with vaginal photoplethysmography. Data analysis with traditional methods comparing average genital arousal between films failed to detect specificity of genital arousal for either group. When data were analyzed with smoothing regression splines and a within-subjects approach, both heterosexual and lesbian women demonstrated different patterns of genital sexual arousal to the different types of erotic films, suggesting that sophisticated statistical techniques may be necessary to more fully understand women's genital sexual arousal response. Heterosexual women showed category-specific genital sexual arousal. Lesbian women showed higher arousal to the heterosexual film than the other films. However, within subjects, lesbian women showed significantly different arousal responses suggesting that lesbian women's genital arousal discriminates between different categories of stimuli at the individual level. Implications for the future use of vaginal photoplethysmography as a diagnostic tool of sexual preferences in clinical and forensic settings are discussed. © 2015 Society for Psychophysiological Research.
A Case Study on Pre-Service Teachers Students' Interaction with Graphical Artefacts
ERIC Educational Resources Information Center
Olande, Oduor
2014-01-01
This study reports from a pre-service teacher's online learning and assessment activity on determining variability of two graphical artefacts. Using a critical-analytical perspective to data, the present study indicates that the prospective teachers surveyed showed awareness of relevant subject specific operators and methods; however, these seem…
Peng, Jie; He, Xiang; Ye, Hanming
2015-01-01
The vacuum preloading is an effective method which is widely used in ground treatment. In consolidation analysis, the soil around prefabricated vertical drain (PVD) is traditionally divided into smear zone and undisturbed zone, both with constant permeability. In reality, the permeability of soil changes continuously within the smear zone. In this study, the horizontal permeability coefficient of soil within the smear zone is described by an exponential function of radial distance. A solution for vacuum preloading consolidation considers the nonlinear distribution of horizontal permeability within the smear zone is presented and compared with previous analytical results as well as a numerical solution, the results show that the presented solution correlates well with the numerical solution, and is more precise than previous analytical solution.
Peng, Jie; He, Xiang; Ye, Hanming
2015-01-01
The vacuum preloading is an effective method which is widely used in ground treatment. In consolidation analysis, the soil around prefabricated vertical drain (PVD) is traditionally divided into smear zone and undisturbed zone, both with constant permeability. In reality, the permeability of soil changes continuously within the smear zone. In this study, the horizontal permeability coefficient of soil within the smear zone is described by an exponential function of radial distance. A solution for vacuum preloading consolidation considers the nonlinear distribution of horizontal permeability within the smear zone is presented and compared with previous analytical results as well as a numerical solution, the results show that the presented solution correlates well with the numerical solution, and is more precise than previous analytical solution. PMID:26447973
NASA Astrophysics Data System (ADS)
Hutt, Axel; Longtin, Andre; Schimansky-Geier, Lutz
2008-05-01
This work studies the spatio-temporal dynamics of a generic integral-differential equation subject to additive random fluctuations. It introduces a combination of the stochastic center manifold approach for stochastic differential equations and the adiabatic elimination for Fokker-Planck equations, and studies analytically the systems’ stability near Turing bifurcations. In addition two types of fluctuation are studied, namely fluctuations uncorrelated in space and time, and global fluctuations, which are constant in space but uncorrelated in time. We show that the global fluctuations shift the Turing bifurcation threshold. This shift is proportional to the fluctuation variance. Applications to a neural field equation and the Swift-Hohenberg equation reveal the shift of the bifurcation to larger control parameters, which represents a stabilization of the system. All analytical results are confirmed by numerical simulations of the occurring mode equations and the full stochastic integral-differential equation. To gain some insight into experimental manifestations, the sum of uncorrelated and global additive fluctuations is studied numerically and the analytical results on global fluctuations are confirmed qualitatively.
Influence of consumers' cognitive style on results from projective mapping.
Varela, Paula; Antúnez, Lucía; Berget, Ingunn; Oliveira, Denize; Christensen, Kasper; Vidal, Leticia; Naes, Tormod; Ares, Gastón
2017-09-01
Projective mapping (PM), one of the most holistic product profiling methods in approach, is increasingly being used to uncover consumers' perception of products and packages. Assessors rely on a process of synthesis for evaluating product information, which would determine the relative importance of the perceived characteristics they use for mapping them. Individual differences are expected, as participants are not instructed on the characteristics to consider for evaluating the degree of difference among samples, generating different perceptual spaces. Individual differences in cognitive style can affect synthesis processes and thus their perception of similarities and differences among samples. In this study, the influence of the cognitive style in the results of PM was explored. Two consumer studies were performed, one aimed at describing intrinsic sensory characteristics of chocolate flavoured milk and the other one looking into extrinsic (package only) of blueberry yogurts. Consumers completed the wholistic-analytic module of the extended Verbal Imagery Cognitive Styles Test & Extended Cognitive Style Analysis-Wholistic Analytic Test, to characterize their cognitive style. Differences between wholistic and analytic consumers in how they evaluated samples using projective mapping were found in both studies. Analytics separated the samples more in the PM perceptual space than wholistic consumers, showing more discriminating abilities. This may come from a deeper analysis of the samples, both from intrinsic and extrinsic point of views. From a sensory perspective (intrinsic), analytic consumers relied on more sensory characteristics, while wholistic mainly discriminated samples according to sweetness and bitterness/chocolate flavour. In the extrinsic study however, even if analytic consumers discriminated more between packs, they described the products using similar words in the descriptive step. One important recommendation coming from this study is the need to consider higher dimensions in the interpretation of projective mapping tasks, as the first dimensions could underestimate the complexity of the perceptual space; currently, most applications of PM consider two dimensions only, which may not uncover the perception of specific groups of consumers. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sedimentary Geothermal Feasibility Study: October 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Augustine, Chad; Zerpa, Luis
The objective of this project is to analyze the feasibility of commercial geothermal projects using numerical reservoir simulation, considering a sedimentary reservoir with low permeability that requires productivity enhancement. A commercial thermal reservoir simulator (STARS, from Computer Modeling Group, CMG) is used in this work for numerical modeling. In the first stage of this project (FY14), a hypothetical numerical reservoir model was developed, and validated against an analytical solution. The following model parameters were considered to obtain an acceptable match between the numerical and analytical solutions: grid block size, time step and reservoir areal dimensions; the latter related to boundarymore » effects on the numerical solution. Systematic model runs showed that insufficient grid sizing generates numerical dispersion that causes the numerical model to underestimate the thermal breakthrough time compared to the analytic model. As grid sizing is decreased, the model results converge on a solution. Likewise, insufficient reservoir model area introduces boundary effects in the numerical solution that cause the model results to differ from the analytical solution.« less
Effect of crash pulse shape on seat stroke requirements for limiting loads on occupants of aircraft
NASA Technical Reports Server (NTRS)
Carden, Huey D.
1992-01-01
An analytical study was made to provide comparative information on various crash pulse shapes that potentially could be used to test seats under conditions included in Federal Regulations Part 23 Paragraph 23.562(b)(1) for dynamic testing of general aviation seats, show the effects that crash pulse shape can have on the seat stroke requirements necessary to maintain a specified limit loading on the seat/occupant during crash pulse loadings, compare results from certain analytical model pulses with approximations of actual crash pulses, and compare analytical seat results with experimental airplace crash data. Structural and seat/occupant displacement equations in terms of the maximum deceleration, velocity change, limit seat pan load, and pulse time for five potentially useful pulse shapes were derived; from these, analytical seat stroke data were obtained for conditions as specified in Federal Regulations Part 23 Paragraph 23.562(b)(1) for dynamic testing of general aviation seats.
Review of analytical models to stream depletion induced by pumping: Guide to model selection
NASA Astrophysics Data System (ADS)
Huang, Ching-Sheng; Yang, Tao; Yeh, Hund-Der
2018-06-01
Stream depletion due to groundwater extraction by wells may cause impact on aquatic ecosystem in streams, conflict over water rights, and contamination of water from irrigation wells near polluted streams. A variety of studies have been devoted to addressing the issue of stream depletion, but a fundamental framework for analytical modeling developed from aquifer viewpoint has not yet been found. This review shows key differences in existing models regarding the stream depletion problem and provides some guidelines for choosing a proper analytical model in solving the problem of concern. We introduce commonly used models composed of flow equations, boundary conditions, well representations and stream treatments for confined, unconfined, and leaky aquifers. They are briefly evaluated and classified according to six categories of aquifer type, flow dimension, aquifer domain, stream representation, stream channel geometry, and well type. Finally, we recommend promising analytical approaches that can solve stream depletion problem in reality with aquifer heterogeneity and irregular geometry of stream channel. Several unsolved stream depletion problems are also recommended.
Morbioli, Giorgio Gianini; Mazzu-Nascimento, Thiago; Milan, Luis Aparecido; Stockton, Amanda M; Carrilho, Emanuel
2017-05-02
Paper-based devices are a portable, user-friendly, and affordable technology that is one of the best analytical tools for inexpensive diagnostic devices. Three-dimensional microfluidic paper-based analytical devices (3D-μPADs) are an evolution of single layer devices and they permit effective sample dispersion, individual layer treatment, and multiplex analytical assays. Here, we present the rational design of a wax-printed 3D-μPAD that enables more homogeneous permeation of fluids along the cellulose matrix than other existing designs in the literature. Moreover, we show the importance of the rational design of channels on these devices using glucose oxidase, peroxidase, and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) reactions. We present an alternative method for layer stacking using a magnetic apparatus, which facilitates fluidic dispersion and improves the reproducibility of tests performed on 3D-μPADs. We also provide the optimized designs for printing, facilitating further studies using 3D-μPADs.
NASA Astrophysics Data System (ADS)
Li, F. X.; Rajapakse, R. K. N. D.
2007-03-01
Saturated domain orientation textures of three types of pseudocubic (tetragonal, rhombohedral, and orthorhombic) ferroelectric ceramics after complete electric and uniaxial tension (compression) poling is studied analytically in this paper. A one-dimensional orientation distribution function (ODF) of the domain polar vectors is explicitly derived from the uniform inverse pole figures of the poling field axes on a stereographic projection with respect to the fixed crystallite coordinates. The analytical ODF is used to obtain the analytical solutions of saturated polarization and strain after electric/mechanical poling. Based on the closed form solution of the saturated domain orientation textures, the resultant intrinsic electromechanical properties of ferroelectric ceramics, which depend only on the ODF and properties of the corresponding single crystals, are obtained. The results show how the macroscopic symmetries of ferroelectric crystals change from 4mm (tetragonal), 3m (rhombohedral), and mm2 (orthorhombic) single crystals to a ∞mm (transversely isotropic) completely poled ceramic.
An analytical model for scanning electron microscope Type I magnetic contrast with energy filtering
NASA Astrophysics Data System (ADS)
Chim, W. K.
1994-02-01
In this article, a theoretical model for type I magnetic contrast calculations in the scanning electron microscope with energy filtering is presented. This model uses an approximate form of the secondary electron (SE) energy distribution by Chung and Everhart [M. S. Chung and T. E. Everhart, J. Appl. Phys. 45, 707 (1974). Closed form analytical expressions for the contrast and quality factors, which take into consideration the work function and field-distance integral of the material being studied, are obtained. This analytical model is compared with that of a more accurate numerical model. Results showed that the contrast and quality factors for the analytical model differed by not more than 20% from the numerical model, with the actual difference depending on the range of filtered SE energies considered. This model has also been extended to the situation of a two-detector (i.e., detector A and B) configuration, in which enhanced magnetic contrast and quality factor can be obtained by operating in the ``A-B'' mode.
Mainali, Laxman; Vasquez-Vivar, Jeannette; Hyde, James S.; Subczynski, Witold K.
2015-01-01
This study validated the use of small unilamellar vesicles (SUVs) made of 1-palmitoyl-2-oleoylphosphatidylcholine with 1 mol% spin label of 1-palmitoyl-2-(16-doxylstearoyl)phosphatidylcholine (16-PC) as an oxygen sensitive analyte to study cellular respiration. In the analyte the hydrocarbon environment surrounds the nitroxide moiety of 16-PC. This ensures high oxygen concentration and oxygen diffusion at the location of the nitroxide as well as isolation of the nitroxide moiety from cellular reductants and paramagnetic ions that might interfere with spin-label oximetry measurements. The saturation-recovery EPR approach was applied in the analysis since this approach is the most direct method to carry out oximetric studies. It was shown that this display (spin-lattice relaxation rate) is linear in oxygen partial pressure up to 100% air (159 mmHg). Experiments using a neuronal cell line in suspension were carried out at X-band for closed chamber geometry. Oxygen consumption rates showed a linear dependence on the number of cells. Other significant benefits of the analyte are: the fast effective rotational diffusion and slow translational diffusion of the spin-probe is favorable for the measurements, and there is no cross reactivity between oxygen and paramagnetic ions in the lipid bilayer. PMID:26441482
Mainali, Laxman; Vasquez-Vivar, Jeannette; Hyde, James S; Subczynski, Witold K
2015-08-01
This study validated the use of small unilamellar vesicles (SUVs) made of 1-palmitoyl-2-oleoylphosphatidylcholine with 1 mol% spin label of 1-palmitoyl-2-(16-doxylstearoyl)phosphatidylcholine (16-PC) as an oxygen sensitive analyte to study cellular respiration. In the analyte the hydrocarbon environment surrounds the nitroxide moiety of 16-PC. This ensures high oxygen concentration and oxygen diffusion at the location of the nitroxide as well as isolation of the nitroxide moiety from cellular reductants and paramagnetic ions that might interfere with spin-label oximetry measurements. The saturation-recovery EPR approach was applied in the analysis since this approach is the most direct method to carry out oximetric studies. It was shown that this display (spin-lattice relaxation rate) is linear in oxygen partial pressure up to 100% air (159 mmHg). Experiments using a neuronal cell line in suspension were carried out at X-band for closed chamber geometry. Oxygen consumption rates showed a linear dependence on the number of cells. Other significant benefits of the analyte are: the fast effective rotational diffusion and slow translational diffusion of the spin-probe is favorable for the measurements, and there is no cross reactivity between oxygen and paramagnetic ions in the lipid bilayer.
Tides and tidal stress: Applications to Europa
NASA Astrophysics Data System (ADS)
Hurford, Terry Anthony, Jr.
A review of analytical techniques and documentation of previously inaccessible mathematical formulations is applied to study of Jupiter's satellite Europa. Compared with numerical codes that are commonly used to model global tidal effects, analytical models of tidal deformation give deeper insight into the mechanics of tides, and can better reveal the nature of the dependence of observable effects on key parameters. I develop analytical models for tidal deformation of multi-layered bodies. Previous studies of Europa, based on numerical computation, only to show isolated examples from parameter space. My results show a systematic dependence of tidal response on the thicknesses and material parameters of Europa's core, rocky mantle, liquid water ocean, and outer layer of ice. As in the earlier work, I restrict these studies to incompressible materials. Any set of Love numbers h 2 and k 2 which describe a planet's tidal deformation, could be fit by a range of ice thickness values, by adjusting other parameters such as mantle rigidity or core size, an important result for mission planning. Inclusion of compression into multilayer models has been addressed analytically, uncovering several issues that are not explicit in the literature. Full evaluation with compression is here restricted to a uniform sphere. A set of singularities in the classical solution, which correspond to instabilities due to self-gravity has been identified and mapped in parameter space. The analytical models of tidal response yield the stresses anywhere within the body, including on its surface. Crack patterns (such as cycloids) on Europa are probably controlled by these stresses. However, in contrast to previous studies which used a thin shell approximation of the tidal stress, I consider how other tidal models compare with the observed tectonic features. In this way the relationship between Europa's surface tectonics and the global tidal distortion can be constrained. While large-scale tidal deformations probe internal structure deep within a body, small-scale deformations can probe internal structure at shallower depths. I have used photoclinometry to obtain topographic profiles across terrain adjacent to Europan ridges to detect the effects of loading on the lithosphere. Lithospheric thicknesses have been determined and correlated with types and ages of terrain.
Sharma, Teenu; Khurana, Rajneet Kaur; Jain, Atul; Katare, O P; Singh, Bhupinder
2018-05-01
The current research work envisages an analytical quality by design-enabled development of a simple, rapid, sensitive, specific, robust and cost-effective stability-indicating reversed-phase high-performance liquid chromatographic method for determining stress-induced forced-degradation products of sorafenib tosylate (SFN). An Ishikawa fishbone diagram was constructed to embark upon analytical target profile and critical analytical attributes, i.e. peak area, theoretical plates, retention time and peak tailing. Factor screening using Taguchi orthogonal arrays and quality risk assessment studies carried out using failure mode effect analysis aided the selection of critical method parameters, i.e. mobile phase ratio and flow rate potentially affecting the chosen critical analytical attributes. Systematic optimization using response surface methodology of the chosen critical method parameters was carried out employing a two-factor-three-level-13-run, face-centered cubic design. A method operable design region was earmarked providing optimum method performance using numerical and graphical optimization. The optimum method employed a mobile phase composition consisting of acetonitrile and water (containing orthophosphoric acid, pH 4.1) at 65:35 v/v at a flow rate of 0.8 mL/min with UV detection at 265 nm using a C 18 column. Response surface methodology validation studies confirmed good efficiency and sensitivity of the developed method for analysis of SFN in mobile phase as well as in human plasma matrix. The forced degradation studies were conducted under different recommended stress conditions as per ICH Q1A (R2). Mass spectroscopy studies showed that SFN degrades in strongly acidic, alkaline and oxidative hydrolytic conditions at elevated temperature, while the drug was per se found to be photostable. Oxidative hydrolysis using 30% H 2 O 2 showed maximum degradation with products at retention times of 3.35, 3.65, 4.20 and 5.67 min. The absence of any significant change in the retention time of SFN and degradation products, formed under different stress conditions, ratified selectivity and specificity of the systematically developed method. Copyright © 2017 John Wiley & Sons, Ltd.
Fasoli, Diego; Cattani, Anna; Panzeri, Stefano
2018-05-01
Despite their biological plausibility, neural network models with asymmetric weights are rarely solved analytically, and closed-form solutions are available only in some limiting cases or in some mean-field approximations. We found exact analytical solutions of an asymmetric spin model of neural networks with arbitrary size without resorting to any approximation, and we comprehensively studied its dynamical and statistical properties. The network had discrete time evolution equations and binary firing rates, and it could be driven by noise with any distribution. We found analytical expressions of the conditional and stationary joint probability distributions of the membrane potentials and the firing rates. By manipulating the conditional probability distribution of the firing rates, we extend to stochastic networks the associating learning rule previously introduced by Personnaz and coworkers. The new learning rule allowed the safe storage, under the presence of noise, of point and cyclic attractors, with useful implications for content-addressable memories. Furthermore, we studied the bifurcation structure of the network dynamics in the zero-noise limit. We analytically derived examples of the codimension 1 and codimension 2 bifurcation diagrams of the network, which describe how the neuronal dynamics changes with the external stimuli. This showed that the network may undergo transitions among multistable regimes, oscillatory behavior elicited by asymmetric synaptic connections, and various forms of spontaneous symmetry breaking. We also calculated analytically groupwise correlations of neural activity in the network in the stationary regime. This revealed neuronal regimes where, statistically, the membrane potentials and the firing rates are either synchronous or asynchronous. Our results are valid for networks with any number of neurons, although our equations can be realistically solved only for small networks. For completeness, we also derived the network equations in the thermodynamic limit of infinite network size and we analytically studied their local bifurcations. All the analytical results were extensively validated by numerical simulations.
Analytical procedure validation and the quality by design paradigm.
Rozet, Eric; Lebrun, Pierre; Michiels, Jean-François; Sondag, Perceval; Scherder, Tara; Boulanger, Bruno
2015-01-01
Since the adoption of the ICH Q8 document concerning the development of pharmaceutical processes following a quality by design (QbD) approach, there have been many discussions on the opportunity for analytical procedure developments to follow a similar approach. While development and optimization of analytical procedure following QbD principles have been largely discussed and described, the place of analytical procedure validation in this framework has not been clarified. This article aims at showing that analytical procedure validation is fully integrated into the QbD paradigm and is an essential step in developing analytical procedures that are effectively fit for purpose. Adequate statistical methodologies have also their role to play: such as design of experiments, statistical modeling, and probabilistic statements. The outcome of analytical procedure validation is also an analytical procedure design space, and from it, control strategy can be set.
AERIAL SHOWING COMPLETED REMOTE ANALYTICAL FACILITY (CPP627) ADJOINING FUEL PROCESSING ...
AERIAL SHOWING COMPLETED REMOTE ANALYTICAL FACILITY (CPP-627) ADJOINING FUEL PROCESSING BUILDING AND EXCAVATION FOR HOT PILOT PLANT TO RIGHT (CPP-640). INL PHOTO NUMBER NRTS-60-1221. J. Anderson, Photographer, 3/22/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Low-frequency analogue Hawking radiation: The Bogoliubov-de Gennes model
NASA Astrophysics Data System (ADS)
Coutant, Antonin; Weinfurtner, Silke
2018-01-01
We analytically study the low-frequency properties of the analogue Hawking effect in Bose-Einstein condensates. We show that in one-dimensional flows displaying an analogue horizon, the Hawking effect is dominant in the low-frequency regime. This happens despite nonvanishing grey-body factors, that is, the coupling of the Hawking mode and its partner to the mode propagating with the flow. To show this, we obtained analytical expressions for the scattering coefficients, in general flows and taking into account the full Bogoliubov dispersion relation. We discuss the obtained expressions for the grey-body factors. In particular, we show that they can be significantly decreased if the flow obeys a conformal coupling condition. We argue that in the presence of a small but non-zero temperature, reducing grey-body factors greatly facilitates the observation of entanglement, that is, establishing that the state of the Hawking mode and its partner is non-separable.
Using Cooperative Learning to Teach Chemistry: A Meta-Analytic Review
ERIC Educational Resources Information Center
Warfa, Abdi-Rizak M.
2016-01-01
A meta-analysis of recent quantitative studies that examine the effects of cooperative learning (CL) on achievement outcomes in chemistry is presented. Findings from 25 chemical education studies involving 3985 participants (N[subscript treatment] = 1,845; N[subscript control] = 2,140) and published since 2001 show positive association between…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, S.R.; Wilkinson, E.J.
Within the endometrial cavity intrauterine contraceptive devices (IUDs) become encrusted with cellular, acellular, and fibrillar substances. Scanning electron microscopy was used to study the crust. Cellular material consisted mainly of blood cells and various types of bacteria. The fibrillar material appeared to be fibrin which was omnipresent in the crust and formed a thin layer immediately over the IUD surface. X-ray microanalysis of the acellular component of the crust revealed the presence of calcium. No other major peaks were identified. Near the IUD surface characteristic calcium phosphate crystals were present. Their microanalysis showed peaks for calcium and phosphorus. X-ray diffractionmore » of the crust however, showed it to contain only calcite. It is through the use of scanning electron microscopy that calcium phosphate has been detected in the IUD crust and a fibrillar layer has been visualized on the IUD surface. This study further demonstrates the effectiveness of SEM analytical techniques in the area of biomedical research.« less
Supercritical flow characteristics at abrupt expansion structure
NASA Astrophysics Data System (ADS)
Lim, Jia Jun; Puay, How Tion; Zakaria, Nor Azazi
2017-10-01
When dealing with the design of a hydraulic structure, lateral expansion is often necessary for flow emerging at high velocity served as a cross-sectional transition. If the abrupt expansion structure is made to diverge rapidly, it will cause the major part of the flow fail to follow the boundaries. If the transition is too gradual, it will result in a waste of structural material. A preliminary study on the flow structure near the expansion and its relationship with flow parameter is carried out in this study. A two-dimensional depth-averaged model is developed to simulate the supercritical flow at the abrupt expansion structure. Constrained Interpolation Profile (CIP) scheme (which is of third order accuracy) is adopted in the numerical model. Results show that the flow structure and flow characteristics at the abrupt expansion can be reproduced numerically. The validation of numerical result is done against analytical studies. The result from numerical simulation showed good agreement with the analytical solution.
[Sustainability analysis of an evaluation policy: the case of primary health care in Brazil].
Felisberto, Eronildo; Freese, Eduardo; Bezerra, Luciana Caroline Albuquerque; Alves, Cinthia Kalyne de Almeida; Samico, Isabella
2010-06-01
This study analyzes the sustainability of Brazil's National Policy for the Evaluation of Primary Health Care, based on the identification and categorization of representative critical events in the institutionalization process. This was an evaluative study of two analytical units: Federal Management of Primary Health Care and State Health Secretariats, using multiple case studies with data collected through interviews and institutional documents, using the critical incidents technique. Events that were temporally classified as specific to implementation, sustainability, and mixed were categorized analytically as pertaining to memory, adaptation, values, and rules. Federal management and one of the State Health Secretariats showed medium-level sustainability, while the other State Secretariat showed strong sustainability. The results indicate that the events were concurrent and suggest a weighting process, since the adaptation of activities, adequacy, and stabilization of resources displayed a strong influence on the others. Innovations and the development of technical capability are considered the most important results for sustainability.
Paseiro-Cerrato, R; de Quirós, A Rodríguez-Bernaldo; Sendón, Raquel; Bustos, Juana; Ruíz, E; Cruz, J M; Paseiro-Losada, P
2011-10-07
This paper describes the development of a multi-analyte method for the determination of polyfunctional amines commonly used as monomers in the manufacture of food contact materials. Amines were analyzed by high-performance-liquid chromatography with diode-array detection (HPLC-DAD) after derivatization with dansyl chloride. The chromatographic analysis and the derivatization conditions were optimized. The proposed method was validated in terms of linearity, limits of detection and repeatabilities. The method showed an excellent sensitivity (LOD≤0.05 μg/mL) and appropriate repeatabilites (RSD (n=7)≤5%)). LC-MS/MS was used as a confirmatory technique. The stability of the amines in five food simulants (distilled water, 3% acetic acid, 10% ethanol, 50% ethanol and olive oil) under the most common testing conditions (10 days at 40 °C) was also studied. Results showed that amines had an acceptable stability in aqueous simulants but in the olive oil a loss of 100% was observed for all analytes. Copyright © 2011. Published by Elsevier B.V.
Analytically optimal parameters of dynamic vibration absorber with negative stiffness
NASA Astrophysics Data System (ADS)
Shen, Yongjun; Peng, Haibo; Li, Xianghong; Yang, Shaopu
2017-02-01
In this paper the optimal parameters of a dynamic vibration absorber (DVA) with negative stiffness is analytically studied. The analytical solution is obtained by Laplace transform method when the primary system is subjected to harmonic excitation. The research shows there are still two fixed points independent of the absorber damping in the amplitude-frequency curve of the primary system when the system contains negative stiffness. Then the optimum frequency ratio and optimum damping ratio are respectively obtained based on the fixed-point theory. A new strategy is proposed to obtain the optimum negative stiffness ratio and make the system remain stable at the same time. At last the control performance of the presented DVA is compared with those of three existing typical DVAs, which were presented by Den Hartog, Ren and Sims respectively. The comparison results in harmonic and random excitation show that the presented DVA in this paper could not only reduce the peak value of the amplitude-frequency curve of the primary system significantly, but also broaden the efficient frequency range of vibration mitigation.
Cavity-coupled double-quantum dot at finite bias: Analogy with lasers and beyond
NASA Astrophysics Data System (ADS)
Kulkarni, Manas; Cotlet, Ovidiu; Türeci, Hakan E.
2014-09-01
We present a theoretical and experimental study of photonic and electronic transport properties of a voltage biased InAs semiconductor double quantum dot (DQD) that is dipole coupled to a superconducting transmission line resonator. We obtain the master equation for the reduced density matrix of the coupled system of cavity photons and DQD electrons accounting systematically for both the presence of phonons and the effect of leads at finite voltage bias. We subsequently derive analytical expressions for transmission, phase response, photon number, and the nonequilibrium steady-state electron current. We show that the coupled system under finite bias realizes an unconventional version of a single-atom laser and analyze the spectrum and the statistics of the photon flux leaving the cavity. In the transmission mode, the system behaves as a saturable single-atom amplifier for the incoming photon flux. Finally, we show that the back action of the photon emission on the steady-state current can be substantial. Our analytical results are compared to exact master equation results establishing regimes of validity of various analytical models. We compare our findings to available experimental measurements.
NASA Astrophysics Data System (ADS)
Chen, Jui-Sheng; Liu, Chen-Wuing; Liang, Ching-Ping; Lai, Keng-Hsin
2012-08-01
SummaryMulti-species advective-dispersive transport equations sequentially coupled with first-order decay reactions are widely used to describe the transport and fate of the decay chain contaminants such as radionuclide, chlorinated solvents, and nitrogen. Although researchers attempted to present various types of methods for analytically solving this transport equation system, the currently available solutions are mostly limited to an infinite or a semi-infinite domain. A generalized analytical solution for the coupled multi-species transport problem in a finite domain associated with an arbitrary time-dependent source boundary is not available in the published literature. In this study, we first derive generalized analytical solutions for this transport problem in a finite domain involving arbitrary number of species subject to an arbitrary time-dependent source boundary. Subsequently, we adopt these derived generalized analytical solutions to obtain explicit analytical solutions for a special-case transport scenario involving an exponentially decaying Bateman type time-dependent source boundary. We test the derived special-case solutions against the previously published coupled 4-species transport solution and the corresponding numerical solution with coupled 10-species transport to conduct the solution verification. Finally, we compare the new analytical solutions derived for a finite domain against the published analytical solutions derived for a semi-infinite domain to illustrate the effect of the exit boundary condition on coupled multi-species transport with an exponential decaying source boundary. The results show noticeable discrepancies between the breakthrough curves of all the species in the immediate vicinity of the exit boundary obtained from the analytical solutions for a finite domain and a semi-infinite domain for the dispersion-dominated condition.
Learning Visualization Strategies: A qualitative investigation
NASA Astrophysics Data System (ADS)
Halpern, Daniel; Oh, Kyong Eun; Tremaine, Marilyn; Chiang, James; Bemis, Karen; Silver, Deborah
2015-12-01
The following study investigates the range of strategies individuals develop to infer and interpret cross-sections of three-dimensional objects. We focus on the identification of mental representations and problem-solving processes made by 11 individuals with the goal of building training applications that integrate the strategies developed by the participants in our study. Our results suggest that although spatial transformation and perspective-taking techniques are useful for visualizing cross-section problems, these visual processes are augmented by analytical thinking. Further, our study shows that participants employ general analytic strategies for extended periods which evolve through practice into a set of progressively more expert strategies. Theoretical implications are discussed and five main findings are recommended for integration into the design of education software that facilitates visual learning and comprehension.
Modeling of classical swirl injector dynamics
NASA Astrophysics Data System (ADS)
Ismailov, Maksud M.
The knowledge of the dynamics of a swirl injector is crucial in designing a stable liquid rocket engine. Since the swirl injector is a complex fluid flow device in itself, not much work has been conducted to describe its dynamics either analytically or by using computational fluid dynamics techniques. Even the experimental observation is limited up to date. Thus far, there exists an analytical linear theory by Bazarov [1], which is based on long-wave disturbances traveling on the free surface of the injector core. This theory does not account for variation of the nozzle reflection coefficient as a function of disturbance frequency, and yields a response function which is strongly dependent on the so called artificial viscosity factor. This causes an uncertainty in designing an injector for the given operational combustion instability frequencies in the rocket engine. In this work, the author has studied alternative techniques to describe the swirl injector response, both analytically and computationally. In the analytical part, by using the linear small perturbation analysis, the entire phenomenon of unsteady flow in swirl injectors is dissected into fundamental components, which are the phenomena of disturbance wave refraction and reflection, and vortex chamber resonance. This reveals the nature of flow instability and the driving factors leading to maximum injector response. In the computational part, by employing the nonlinear boundary element method (BEM), the author sets the boundary conditions such that they closely simulate those in the analytical part. The simulation results then show distinct peak responses at frequencies that are coincident with those resonant frequencies predicted in the analytical part. Moreover, a cold flow test of the injector related to this study also shows a clear growth of instability with its maximum amplitude at the first fundamental frequency predicted both by analytical methods and BEM. It shall be noted however that Bazarov's theory does not predict the resonant peaks. Overall this methodology provides clearer understanding of the injector dynamics compared to Bazarov's. Even though the exact value of response is not possible to obtain at this stage of theoretical, computational, and experimental investigation, this methodology sets the starting point from where the theoretical description of reflection/refraction, resonance, and their interaction between each other may be refined to higher order to obtain its more precise value.
Do placebo based validation standards mimic real batch products behaviour? Case studies.
Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E
2011-06-01
Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Jui-Sheng; Li, Loretta Y.; Lai, Keng-Hsin; Liang, Ching-Ping
2017-11-01
A novel solution method is presented which leads to an analytical model for the advective-dispersive transport in a semi-infinite domain involving a wide spectrum of boundary inputs, initial distributions, and zero-order productions. The novel solution method applies the Laplace transform in combination with the generalized integral transform technique (GITT) to obtain the generalized analytical solution. Based on this generalized analytical expression, we derive a comprehensive set of special-case solutions for some time-dependent boundary distributions and zero-order productions, described by the Dirac delta, constant, Heaviside, exponentially-decaying, or periodically sinusoidal functions as well as some position-dependent initial conditions and zero-order productions specified by the Dirac delta, constant, Heaviside, or exponentially-decaying functions. The developed solutions are tested against an analytical solution from the literature. The excellent agreement between the analytical solutions confirms that the new model can serve as an effective tool for investigating transport behaviors under different scenarios. Several examples of applications, are given to explore transport behaviors which are rarely noted in the literature. The results show that the concentration waves resulting from the periodically sinusoidal input are sensitive to dispersion coefficient. The implication of this new finding is that a tracer test with a periodic input may provide additional information when for identifying the dispersion coefficients. Moreover, the solution strategy presented in this study can be extended to derive analytical models for handling more complicated problems of solute transport in multi-dimensional media subjected to sequential decay chain reactions, for which analytical solutions are not currently available.
Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre
2011-11-01
The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.
Enabling Analytics on Sensitive Medical Data with Secure Multi-Party Computation.
Veeningen, Meilof; Chatterjea, Supriyo; Horváth, Anna Zsófia; Spindler, Gerald; Boersma, Eric; van der Spek, Peter; van der Galiën, Onno; Gutteling, Job; Kraaij, Wessel; Veugen, Thijs
2018-01-01
While there is a clear need to apply data analytics in the healthcare sector, this is often difficult because it requires combining sensitive data from multiple data sources. In this paper, we show how the cryptographic technique of secure multi-party computation can enable such data analytics by performing analytics without the need to share the underlying data. We discuss the issue of compliance to European privacy legislation; report on three pilots bringing these techniques closer to practice; and discuss the main challenges ahead to make fully privacy-preserving data analytics in the medical sector commonplace.
Bai, Ru; Zhang, Lili; Liu, Ying; Li, Bai; Wang, Liming; Wang, Peng; Autrup, Herman; Beer, Christiane; Chen, Chunying
2014-04-07
Health impacts of inhalation exposure to engineered nanomaterials have attracted increasing attention. In this paper, integrated analytical techniques with high sensitivity were used to study the brain translocation and potential impairment induced by intranasally instilled copper nanoparticles (CuNPs). Mice were exposed to CuNPs in three doses (1, 10, 40 mg/kg bw). The body weight of mice decreased significantly in the 10 and 40 mg/kg group (p<0.05) but recovered slightly within exposure duration. Inductively coupled plasma mass spectrometry (ICP-MS) analysis showed that CuNPs could enter the brain. Altered distribution of some important metal elements was observed by synchrotron radiation X-ray fluorescence (SRXRF). H&E staining and immunohistochemical analysis showed that CuNPs produced damages to nerve cells and astrocyte might be the one of the potential targets of CuNPs. The changes of neurotransmitter levels in different brain regions demonstrate that the dysfunction occurred in exposed groups. These data indicated that CuNPs could enter the brain after nasal inhalation and induced damages to the central nervous system (CNS). Integration of effective analytical techniques for systematic investigations is a promising direction to better understand the biological activities of nanomaterials. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Validation of an assay for quantification of alpha-amylase in saliva of sheep
Fuentes-Rubio, Maria; Fuentes, Francisco; Otal, Julio; Quiles, Alberto; Hevia, María Luisa
2016-01-01
The objective of this study was to develop a time-resolved immunofluorometric assay (TR-IFMA) for quantification of salivary alpha-amylase in sheep. For that purpose, after the design of the assay, an analytical and a clinical validation were carried out. The analytical validation of the assay showed intra- and inter-assay coefficients of variation (CVs) of 6.1% and 10.57%, respectively and an analytical limit of detection of 0.09 ng/mL. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution. For clinical validation, a model of acute stress testing was conducted to determine whether expected significant changes in alpha-amylase were picked up in the newly developed assay. In that model, 11 sheep were immobilized and confronted with a sheepdog to induce stress. Saliva samples were obtained before stress induction and 15, 30, and 60 min afterwards. Salivary cortisol was measured as a reference of stress level. The results of TR-IFMA showed a significant increase (P < 0.01) in the concentration of alpha-amylase in saliva after stress induction. The assay developed in this study could be used to measure salivary alpha-amylase in the saliva of sheep and this enzyme could be a possible noninvasive biomarker of stress in sheep. PMID:27408332
Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju
2018-06-01
To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.
Pre-analytical method for NMR-based grape metabolic fingerprinting and chemometrics.
Ali, Kashif; Maltese, Federica; Fortes, Ana Margarida; Pais, Maria Salomé; Verpoorte, Robert; Choi, Young Hae
2011-10-10
Although metabolomics aims at profiling all the metabolites in organisms, data quality is quite dependent on the pre-analytical methods employed. In order to evaluate current methods, different pre-analytical methods were compared and used for the metabolic profiling of grapevine as a model plant. Five grape cultivars from Portugal in combination with chemometrics were analyzed in this study. A common extraction method with deuterated water and methanol was found effective in the case of amino acids, organic acids, and sugars. For secondary metabolites like phenolics, solid phase extraction with C-18 cartridges showed good results. Principal component analysis, in combination with NMR spectroscopy, was applied and showed clear distinction among the cultivars. Primary metabolites such as choline, sucrose, and leucine were found discriminating for 'Alvarinho', while elevated levels of alanine, valine, and acetate were found in 'Arinto' (white varieties). Among the red cultivars, higher signals for citrate and GABA in 'Touriga Nacional', succinate and fumarate in 'Aragonês', and malate, ascorbate, fructose and glucose in 'Trincadeira', were observed. Based on the phenolic profile, 'Arinto' was found with higher levels of phenolics as compared to 'Alvarinho'. 'Trincadeira' showed lowest phenolics content while higher levels of flavonoids and phenylpropanoids were found in 'Aragonês' and 'Touriga Nacional', respectively. It is shown that the metabolite composition of the extract is highly affected by the extraction procedure and this consideration has to be taken in account for metabolomics studies. Copyright © 2011 Elsevier B.V. All rights reserved.
Park, Seungman; Kang, Youjin; Kim, Dong Geun; Kim, Eui-Chong; Park, Sung Sup; Seong, Moon-Woo
2013-08-01
The detection of high-risk (HR) HPV in cervical cancer screening is important for early diagnosis of cervical cancer or pre-cancerous lesions. We evaluated the analytical and clinical performances of 3 HR HPV assays in Gynecology patients. A total of 991 specimens were included in this study: 787 specimens for use with a Hybrid Capture 2 (HC2) and 204 specimens for a HPV DNA microarray (DNA Chip). All specimens were tested using an Abbott RealTime High Risk HPV assay (Real-time HR), PGMY PCR, and sequence analysis. Clinical sensitivities for severe abnormal cytology (severe than high-grade squamous intraepithelial lesion) were 81.8% for Real-time HR, 77.3% for HC2, and 66.7% for DNA Chip, and clinical sensitivities for severe abnormal histology (cervical intraepithelial neoplasia grade 2+) were 91.7% for HC2, 87.5% for Real-time HR, and 73.3% for DNA Chip. As compared to results of the sequence analysis, HC2, Real-time HR, and DNA Chip showed concordance rates of 94.3% (115/122), 90.0% (117/130), and 61.5% (16/26), respectively. The HC2 assay and Real-time HR assay showed comparable results to each other in both clinical and analytical performances, while the DNA Chip assay showed poor clinical and analytical performances. The Real-time HR assay can be a good alternative option for HR HPV testing with advantages of allowing full automation and simultaneous genotyping of HR types 16 and 18. Copyright © 2013 Elsevier Inc. All rights reserved.
Developmental changes in analytic and holistic processes in face perception.
Joseph, Jane E; DiBartolo, Michelle D; Bhatt, Ramesh S
2015-01-01
Although infants demonstrate sensitivity to some kinds of perceptual information in faces, many face capacities continue to develop throughout childhood. One debate is the degree to which children perceive faces analytically versus holistically and how these processes undergo developmental change. In the present study, school-aged children and adults performed a perceptual matching task with upright and inverted face and house pairs that varied in similarity of featural or 2(nd) order configural information. Holistic processing was operationalized as the degree of serial processing when discriminating faces and houses [i.e., increased reaction time (RT), as more features or spacing relations were shared between stimuli]. Analytical processing was operationalized as the degree of parallel processing (or no change in RT as a function of greater similarity of features or spatial relations). Adults showed the most evidence for holistic processing (most strongly for 2(nd) order faces) and holistic processing was weaker for inverted faces and houses. Younger children (6-8 years), in contrast, showed analytical processing across all experimental manipulations. Older children (9-11 years) showed an intermediate pattern with a trend toward holistic processing of 2(nd) order faces like adults, but parallel processing in other experimental conditions like younger children. These findings indicate that holistic face representations emerge around 10 years of age. In adults both 2(nd) order and featural information are incorporated into holistic representations, whereas older children only incorporate 2(nd) order information. Holistic processing was not evident in younger children. Hence, the development of holistic face representations relies on 2(nd) order processing initially then incorporates featural information by adulthood.
ClimateSpark: An in-memory distributed computing framework for big climate data analytics
NASA Astrophysics Data System (ADS)
Hu, Fei; Yang, Chaowei; Schnase, John L.; Duffy, Daniel Q.; Xu, Mengchao; Bowen, Michael K.; Lee, Tsengdar; Song, Weiwei
2018-06-01
The unprecedented growth of climate data creates new opportunities for climate studies, and yet big climate data pose a grand challenge to climatologists to efficiently manage and analyze big data. The complexity of climate data content and analytical algorithms increases the difficulty of implementing algorithms on high performance computing systems. This paper proposes an in-memory, distributed computing framework, ClimateSpark, to facilitate complex big data analytics and time-consuming computational tasks. Chunking data structure improves parallel I/O efficiency, while a spatiotemporal index is built for the chunks to avoid unnecessary data reading and preprocessing. An integrated, multi-dimensional, array-based data model (ClimateRDD) and ETL operations are developed to address big climate data variety by integrating the processing components of the climate data lifecycle. ClimateSpark utilizes Spark SQL and Apache Zeppelin to develop a web portal to facilitate the interaction among climatologists, climate data, analytic operations and computing resources (e.g., using SQL query and Scala/Python notebook). Experimental results show that ClimateSpark conducts different spatiotemporal data queries/analytics with high efficiency and data locality. ClimateSpark is easily adaptable to other big multiple-dimensional, array-based datasets in various geoscience domains.
NASA Astrophysics Data System (ADS)
Shevade, Abhijit V.; Ryan, Margaret A.; Homer, Margie L.; Zhou, Hanying; Manfreda, Allison M.; Lara, Liana M.; Yen, Shiao-Pin S.; Jewell, April D.; Manatt, Kenneth S.; Kisor, Adam K.
We have developed a Quantitative Structure-Activity Relationships (QSAR) based approach to correlate the response of chemical sensors in an array with molecular descriptors. A novel molecular descriptor set has been developed; this set combines descriptors of sensing film-analyte interactions, representing sensor response, with a basic analyte descriptor set commonly used in QSAR studies. The descriptors are obtained using a combination of molecular modeling tools and empirical and semi-empirical Quantitative Structure-Property Relationships (QSPR) methods. The sensors under investigation are polymer-carbon sensing films which have been exposed to analyte vapors at parts-per-million (ppm) concentrations; response is measured as change in film resistance. Statistically validated QSAR models have been developed using Genetic Function Approximations (GFA) for a sensor array for a given training data set. The applicability of the sensor response models has been tested by using it to predict the sensor activities for test analytes not considered in the training set for the model development. The validated QSAR sensor response models show good predictive ability. The QSAR approach is a promising computational tool for sensing materials evaluation and selection. It can also be used to predict response of an existing sensing film to new target analytes.
An improved 3D MoF method based on analytical partial derivatives
NASA Astrophysics Data System (ADS)
Chen, Xiang; Zhang, Xiong
2016-12-01
MoF (Moment of Fluid) method is one of the most accurate approaches among various surface reconstruction algorithms. As other second order methods, MoF method needs to solve an implicit optimization problem to obtain the optimal approximate surface. Therefore, the partial derivatives of the objective function have to be involved during the iteration for efficiency and accuracy. However, to the best of our knowledge, the derivatives are currently estimated numerically by finite difference approximation because it is very difficult to obtain the analytical derivatives of the object function for an implicit optimization problem. Employing numerical derivatives in an iteration not only increase the computational cost, but also deteriorate the convergence rate and robustness of the iteration due to their numerical error. In this paper, the analytical first order partial derivatives of the objective function are deduced for 3D problems. The analytical derivatives can be calculated accurately, so they are incorporated into the MoF method to improve its accuracy, efficiency and robustness. Numerical studies show that by using the analytical derivatives the iterations are converged in all mixed cells with the efficiency improvement of 3 to 4 times.
Bassuoni, M M
2014-03-01
The dehumidifier is a key component in liquid desiccant air-conditioning systems. Analytical solutions have more advantages than numerical solutions in studying the dehumidifier performance parameters. This paper presents the performance results of exit parameters from an analytical model of an adiabatic cross-flow liquid desiccant air dehumidifier. Calcium chloride is used as desiccant material in this investigation. A program performing the analytical solution is developed using the engineering equation solver software. Good accuracy has been found between analytical solution and reliable experimental results with a maximum deviation of +6.63% and -5.65% in the moisture removal rate. The method developed here can be used in the quick prediction of the dehumidifier performance. The exit parameters from the dehumidifier are evaluated under the effects of variables such as air temperature and humidity, desiccant temperature and concentration, and air to desiccant flow rates. The results show that hot humid air and desiccant concentration have the greatest impact on the performance of the dehumidifier. The moisture removal rate is decreased with increasing both air inlet temperature and desiccant temperature while increases with increasing air to solution mass ratio, inlet desiccant concentration, and inlet air humidity ratio.
A Unifying Review of Bioassay-Guided Fractionation, Effect-Directed Analysis and Related Techniques
Weller, Michael G.
2012-01-01
The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions. PMID:23012539
Analytical slave-spin mean-field approach to orbital selective Mott insulators
NASA Astrophysics Data System (ADS)
Komijani, Yashar; Kotliar, Gabriel
2017-09-01
We use the slave-spin mean-field approach to study particle-hole symmetric one- and two-band Hubbard models in the presence of Hund's coupling interaction. By analytical analysis of the Hamiltonian, we show that the locking of the two orbitals vs orbital selective Mott transition can be formulated within a Landau-Ginzburg framework. By applying the slave-spin mean field to impurity problems, we are able to make a correspondence between impurity and lattice. We also consider the stability of the orbital selective Mott phase to the hybridization between the orbitals and study the limitations of the slave-spin method for treating interorbital tunnelings in the case of multiorbital Bethe lattices with particle-hole symmetry.
Laser modification of graphene oxide layers
NASA Astrophysics Data System (ADS)
Malinský, Petr; Macková, Anna; Cutroneo, Mariapompea; Siegel, Jakub; Bohačová, Marie; Klímova, Kateřina; Švorčík, Václav; Sofer, Zdenĕk
2018-01-01
The effect of linearly polarized laser irradiation with various energy densities was successfully used for reduction of graphene oxide (GO). The ion beam analytical methods (RBS, ERDA) were used to follow the elemental composition which is expected as the consequence of GO reduction. The chemical composition analysis was accompanied by structural study showing changed functionalities in the irradiated GO foils using spectroscopy techniques including XPS, FTIR and Raman spectroscopy. The AFM was employed to identify the surface morphology and electric properties evolution were subsequently studied using standard two point method measurement. The used analytical methods report on reduction of irradiated graphene oxide on the surface and the decrease of surface resistivity as a growing function of the laser beam energy density.
Analytic hierarchy process (AHP) as a tool in asset allocation
NASA Astrophysics Data System (ADS)
Zainol Abidin, Siti Nazifah; Mohd Jaffar, Maheran
2013-04-01
Allocation capital investment into different assets is the best way to balance the risk and reward. This can prevent from losing big amount of money. Thus, the aim of this paper is to help investors in making wise investment decision in asset allocation. This paper proposes modifying and adapting Analytic Hierarchy Process (AHP) model. The AHP model is widely used in various fields of study that are related in decision making. The results of the case studies show that the proposed model can categorize stocks and determine the portion of capital investment. Hence, it can assist investors in decision making process and reduce the risk of loss in stock market investment.
Fast 2D Fluid-Analytical Simulation of IEDs and Plasma Uniformity in Multi-frequency CCPs
NASA Astrophysics Data System (ADS)
Kawamura, E.; Lieberman, M. A.; Graves, D. B.
2014-10-01
A fast 2D axisymmetric fluid-analytical model using the finite elements tool COMSOL is interfaced with a 1D particle-in-cell (PIC) code to study ion energy distributions (IEDs) in multi-frequency argon capacitively coupled plasmas (CCPs). A bulk fluid plasma model which solves the time-dependent plasma fluid equations is coupled with an analytical sheath model which solves for the sheath parameters. The fluid-analytical results are used as input to a PIC simulation of the sheath region of the discharge to obtain the IEDs at the wafer electrode. Each fluid-analytical-PIC simulation on a moderate 2.2 GHz CPU workstation with 8 GB of memory took about 15-20 minutes. The 2D multi-frequency fluid-analytical model was compared to 1D PIC simulations of a symmetric parallel plate discharge, showing good agreement. Fluid-analytical simulations of a 2/60/162 MHz argon CCP with a typical asymmetric reactor geometry were also conducted. The low 2 MHz frequency controlled the sheath width and voltage while the higher frequencies controlled the plasma production. A standing wave was observable at the highest frequency of 162 MHz. Adding 2 MHz power to a 60 MHz discharge or 162 MHz to a dual frequency 2 MHz/60 MHz discharge enhanced the plasma uniformity. This work was supported by the Department of Energy Office of Fusion Energy Science Contract DE-SC000193, and in part by gifts from Lam Research Corporation and Micron Corporation.
A study of how the particle spectra of SU(N) gauge theories with a fundamental Higgs emerge
NASA Astrophysics Data System (ADS)
Törek, Pascal; Maas, Axel; Sondenheimer, René
2018-03-01
In gauge theories, the physical, experimentally observable spectrum consists only of gauge-invariant states. In the standard model the Fröhlich-Morchio-Strocchi mechanism shows that these states can be adequately mapped to the gauge-dependent elementary W, Z, Higgs, and fermions. In theories with a more general gauge group and Higgs sector, appearing in various extensions of the standard model, this has not to be the case. In this work we determine analytically the physical spectrum of SU(N > 2) gauge theories with a Higgs field in the fundamental representation. We show that discrepancies between the spectrum predicted by perturbation theory and the observable physical spectrum arise. We confirm these analytic findings with lattice simulations for N = 3.
NASA Astrophysics Data System (ADS)
Mishima, Kenji; Yamashita, Koichi
2011-03-01
We theoretically and numerically investigated a new type of analytically solvable laser-driven systems inspired by electron-injection dynamics in dye-sensitized solar cells. The simple analytical expressions were found to be useful for understanding the difference between dye excitation and direct photo-injection occurring between dye molecule and semiconductor nanoparticles. More importantly, we propose a method for discriminating experimentally dye excitation and direct photo-injection by using time-dependent fluorescence. We found that dye excitation shows no significant quantum beat whereas the direct photo-injection shows a significant quantum beat. This work was supported by Funding Program for World-Leading Innovative R&D on Science and Technology (FIRST) ``Development of Organic Photovoltaics toward a Low-Carbon Society,'' Cabinet Office, Japan.
Analytical Characterisation of Nanoscale Zero-Valent Iron: A Methodological Review
Zero-valent iron nanoparticles (nZVI) have been widely tested as they are showing significant promise for environmental remediation. However, many recent studies have demonstrated that their mobility and reactivity in subsurface environments are significantly affected by their te...
Expert Panels, Consumers, and Chemistry.
ERIC Educational Resources Information Center
Rehfeldt, Thomas K.
2000-01-01
Studied the attributes, properties, and consumer acceptance of antiperspirant products through responses of 400 consumers (consumer data), expert panel data, and analytical data about the products. Results show how the Rasch model can provide the tool necessary to combine data from several sources. (SLD)
Wroble, Julie; Frederick, Timothy; Frame, Alicia; Vallero, Daniel
2017-01-01
Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA)'s Office of Land and Emergency Management (OLEM) currently recommends the rigorous process of Activity Based Sampling (ABS) to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete ("grab") samples and incremental sampling methodology (ISM). Analyses were conducted using polarized light microscopy (PLM), transmission electron microscopy (TEM) methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS) followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples.
2017-01-01
Established soil sampling methods for asbestos are inadequate to support risk assessment and risk-based decision making at Superfund sites due to difficulties in detecting asbestos at low concentrations and difficulty in extrapolating soil concentrations to air concentrations. Environmental Protection Agency (EPA)’s Office of Land and Emergency Management (OLEM) currently recommends the rigorous process of Activity Based Sampling (ABS) to characterize site exposures. The purpose of this study was to compare three soil analytical methods and two soil sampling methods to determine whether one method, or combination of methods, would yield more reliable soil asbestos data than other methods. Samples were collected using both traditional discrete (“grab”) samples and incremental sampling methodology (ISM). Analyses were conducted using polarized light microscopy (PLM), transmission electron microscopy (TEM) methods or a combination of these two methods. Data show that the fluidized bed asbestos segregator (FBAS) followed by TEM analysis could detect asbestos at locations that were not detected using other analytical methods; however, this method exhibited high relative standard deviations, indicating the results may be more variable than other soil asbestos methods. The comparison of samples collected using ISM versus discrete techniques for asbestos resulted in no clear conclusions regarding preferred sampling method. However, analytical results for metals clearly showed that measured concentrations in ISM samples were less variable than discrete samples. PMID:28759607
Dervisevic, Muamer; Senel, Mehmet; Sagir, Tugba; Isik, Sevim
2017-04-15
The detection of cancer cells through important molecular recognition target such as sialic acid is significant for the clinical diagnosis and treatment. There are many electrochemical cytosensors developed for cancer cells detection but most of them have complicated fabrication processes which results in poor reproducibility and reliability. In this study, a simple, low-cost, and highly sensitive electrochemical cytosensor was designed based on boronic acid-functionalized polythiophene. In cytosensors fabrication simple single-step procedure was used which includes coating pencil graphite electrode (PGE) by means of electro-polymerization of 3-Thienyl boronic acid and Thiophen. Electrochemical impedance spectroscopy and cyclic voltammetry were used as an analytical methods to optimize and measure analytical performances of PGE/P(TBA 0.5 Th 0.5 ) based electrode. Cytosensor showed extremely good analytical performances in detection of cancer cells with linear rage of 1×10 1 to 1×10 6 cellsmL -1 exhibiting low detection limit of 10 cellsmL -1 and incubation time of 10min. Next to excellent analytical performances, it showed high selectivity towards AGS cancer cells when compared to HEK 293 normal cells and bone marrow mesenchymal stem cells (BM-hMSCs). This method is promising for future applications in early stage cancer diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Analytical Model of Large Data Transactions in CoAP Networks
Ludovici, Alessandro; Di Marco, Piergiuseppe; Calveras, Anna; Johansson, Karl H.
2014-01-01
We propose a novel analytical model to study fragmentation methods in wireless sensor networks adopting the Constrained Application Protocol (CoAP) and the IEEE 802.15.4 standard for medium access control (MAC). The blockwise transfer technique proposed in CoAP and the 6LoWPAN fragmentation are included in the analysis. The two techniques are compared in terms of reliability and delay, depending on the traffic, the number of nodes and the parameters of the IEEE 802.15.4 MAC. The results are validated trough Monte Carlo simulations. To the best of our knowledge this is the first study that evaluates and compares analytically the performance of CoAP blockwise transfer and 6LoWPAN fragmentation. A major contribution is the possibility to understand the behavior of both techniques with different network conditions. Our results show that 6LoWPAN fragmentation is preferable for delay-constrained applications. For highly congested networks, the blockwise transfer slightly outperforms 6LoWPAN fragmentation in terms of reliability. PMID:25153143
Properties of Traffic Risk Coefficient
NASA Astrophysics Data System (ADS)
Tang, Tie-Qiao; Huang, Hai-Jun; Shang, Hua-Yan; Xue, Yu
2009-10-01
We use the model with the consideration of the traffic interruption probability (Physica A 387(2008)6845) to study the relationship between the traffic risk coefficient and the traffic interruption probability. The analytical and numerical results show that the traffic interruption probability will reduce the traffic risk coefficient and that the reduction is related to the density, which shows that this model can improve traffic security.
Resonant quantum kicked rotor with two internal levels
NASA Astrophysics Data System (ADS)
Hernández, Guzmán; Romanelli, Alejandro
2013-04-01
We study a system consisting of a quantum kicked rotor with an additional degree of freedom. We show analytically and numerically that this model is characterized by its quantum resonances with ballistic spreading and by the entanglement between the internal and momentum degrees of freedom. We conclude that the model shows certain interesting similarities with the standard quantum walk on the line.
Fast analytical scatter estimation using graphics processing units.
Ingleby, Harry; Lippuner, Jonas; Rickey, Daniel W; Li, Yue; Elbakri, Idris
2015-01-01
To develop a fast patient-specific analytical estimator of first-order Compton and Rayleigh scatter in cone-beam computed tomography, implemented using graphics processing units. The authors developed an analytical estimator for first-order Compton and Rayleigh scatter in a cone-beam computed tomography geometry. The estimator was coded using NVIDIA's CUDA environment for execution on an NVIDIA graphics processing unit. Performance of the analytical estimator was validated by comparison with high-count Monte Carlo simulations for two different numerical phantoms. Monoenergetic analytical simulations were compared with monoenergetic and polyenergetic Monte Carlo simulations. Analytical and Monte Carlo scatter estimates were compared both qualitatively, from visual inspection of images and profiles, and quantitatively, using a scaled root-mean-square difference metric. Reconstruction of simulated cone-beam projection data of an anthropomorphic breast phantom illustrated the potential of this method as a component of a scatter correction algorithm. The monoenergetic analytical and Monte Carlo scatter estimates showed very good agreement. The monoenergetic analytical estimates showed good agreement for Compton single scatter and reasonable agreement for Rayleigh single scatter when compared with polyenergetic Monte Carlo estimates. For a voxelized phantom with dimensions 128 × 128 × 128 voxels and a detector with 256 × 256 pixels, the analytical estimator required 669 seconds for a single projection, using a single NVIDIA 9800 GX2 video card. Accounting for first order scatter in cone-beam image reconstruction improves the contrast to noise ratio of the reconstructed images. The analytical scatter estimator, implemented using graphics processing units, provides rapid and accurate estimates of single scatter and with further acceleration and a method to account for multiple scatter may be useful for practical scatter correction schemes.
Ardila, Jorge Armando; Oliveira, Geiser Gabriel; Medeiros, Roberta Antigo; Fatibello-Filho, Orlando
2014-04-07
A highly sensitive method for bezafibrate determination using a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes within a dihexadecyl hydrogen phosphate film based on square-wave adsorptive stripping voltammetry (SWAdSV) is proposed. The electrochemical behaviour of bezafibrate has been studied by cyclic voltammetry, showing an irreversible anodic peak at a potential of 1.09 V in 0.1 mol L(-1) phosphate buffer solution (pH 2.0). A study of the scan rate showed that the oxidation of bezafibrate is an adsorptive-controlled process, involving the transfer of two electrons and two protons per molecule. The analytical curve was linear over a bezafibrate concentration range from 50 to 910 nmol L(-1), with a detection limit of 16 nmol L(-1). This analytical method was successfully applied for benzafibrate determination in pharmaceutical formulations, with results showing good agreement with those obtained using a comparative spectrophotometric method, and has the potential for field application.
Alpha particles diffusion due to charge changes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clauser, C. F., E-mail: cesar.clauser@ib.edu.ar; Farengo, R.
2015-12-15
Alpha particles diffusion due to charge changes in a magnetized plasma is studied. Analytical calculations and numerical simulations are employed to show that this process can be very important in the pedestal-edge-SOL regions. This is the first study that presents clear evidence of the importance of atomic processes on the diffusion of alpha particles. A simple 1D model that includes inelastic collisions with plasma species, “cold” neutrals, and partially ionized species was employed. The code, which follows the exact particle orbits and includes the effect of inelastic collisions via a Monte Carlo type random process, runs on a graphic processormore » unit (GPU). The analytical and numerical results show excellent agreement when a uniform background (plasma and cold species) is assumed. The simulations also show that the gradients in the density of the plasma and cold species, which are large and opposite in the edge region, produce an inward flux of alpha particles. Calculations of the alpha particles flux reaching the walls or divertor plates should include these processes.« less
NASA Astrophysics Data System (ADS)
Rabi, R.; Oufni, L.
2017-10-01
Inhalation of radon (222Rn) and its decay products are a major source of natural radiation exposure. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Indoor air conditions and ventilation systems strongly influence the indoor radon concentration. This study focuses on investigating both numerically and experimentally the influence of environmental conditions on the indoor radon concentration and spatial distribution. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on both radon content and distribution. The variations of radon concentration with the ventilation, temperature and relative humidity are discussed. The measurement results show the diurnal variations of the indoor radon concentration are found to exhibit a positive correlation with relative humidity and negatively correlate with the air temperature. The analytic solution is used to validate the numeric results. The comparison amongst analytical, numerical and measurement results shows close agreement.
Analytic investigation of helicopter rotor blade appended aeroelastic devices
NASA Technical Reports Server (NTRS)
Bielawa, Richard L.
1984-01-01
Analytic evaluations of four different passive aeroelastic devices appended to helicopter rotor blades are presented. The devices consist of a passive tuned tab, a control coupled tab, an all-flying tip and a harmonic dilational airfoil tip. Each device was conceived for improving either aerodynamic performance or reducing vibratory control loads or hub shears. The evaluation was performed using a comprehensive rotor aeroelastic analysis (the G400PA code with appropriate modifications), together with data for a realistic helicopter rotor blade (the UH-60A Blackhawk), in high speed flight (90 m/s, 175 kts). The results of this study show that significant performance (L/(D sub e)) gains can be achieved with the all-flying free tip. Results from the harmonic dilational airfoil tip show the potential for moderate improvements in L/(D sub e). Finally, the results for the passive tuned tab and the control coupled tab, as configured for this study, show these devices to be impractical. Sections are included which describe the operation of each device, the required G400PA modifications, and the detailed results obtained for each device.
Low Mach-number collisionless electrostatic shocks and associated ion acceleration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pusztai, Istvan; TenBarge, Jason; Csapó, Aletta N.
The existence and properties of low Mach-number (M >~ 1) electrostatic collisionless shocks are investigated with a semi-analytical solution for the shock structure. We show that the properties of the shock obtained in the semi-analytical model can be well reproduced in fully kinetic Eulerian Vlasov-Poisson simulations, where the shock is generated by the decay of an initial density discontinuity. By using this semi-analytical model, we also study the effect of electron-to-ion temperature ratio and presence of impurities on both the maximum shock potential and Mach number. We find that even a small amount of impurities can influence the shock propertiesmore » significantly, including the reflected light ion fraction, which can change several orders of magnitude. Electrostatic shocks in heavy ion plasmas reflect most of the hydrogen impurity ions.« less
Low Mach-number collisionless electrostatic shocks and associated ion acceleration
Pusztai, Istvan; TenBarge, Jason; Csapó, Aletta N.; ...
2017-12-19
The existence and properties of low Mach-number (M >~ 1) electrostatic collisionless shocks are investigated with a semi-analytical solution for the shock structure. We show that the properties of the shock obtained in the semi-analytical model can be well reproduced in fully kinetic Eulerian Vlasov-Poisson simulations, where the shock is generated by the decay of an initial density discontinuity. By using this semi-analytical model, we also study the effect of electron-to-ion temperature ratio and presence of impurities on both the maximum shock potential and Mach number. We find that even a small amount of impurities can influence the shock propertiesmore » significantly, including the reflected light ion fraction, which can change several orders of magnitude. Electrostatic shocks in heavy ion plasmas reflect most of the hydrogen impurity ions.« less
Research on bathymetry estimation by Worldview-2 based with the semi-analytical model
NASA Astrophysics Data System (ADS)
Sheng, L.; Bai, J.; Zhou, G.-W.; Zhao, Y.; Li, Y.-C.
2015-04-01
South Sea Islands of China are far away from the mainland, the reefs takes more than 95% of south sea, and most reefs scatter over interested dispute sensitive area. Thus, the methods of obtaining the reefs bathymetry accurately are urgent to be developed. Common used method, including sonar, airborne laser and remote sensing estimation, are limited by the long distance, large area and sensitive location. Remote sensing data provides an effective way for bathymetry estimation without touching over large area, by the relationship between spectrum information and bathymetry. Aimed at the water quality of the south sea of China, our paper develops a bathymetry estimation method without measured water depth. Firstly the semi-analytical optimization model of the theoretical interpretation models has been studied based on the genetic algorithm to optimize the model. Meanwhile, OpenMP parallel computing algorithm has been introduced to greatly increase the speed of the semi-analytical optimization model. One island of south sea in China is selected as our study area, the measured water depth are used to evaluate the accuracy of bathymetry estimation from Worldview-2 multispectral images. The results show that: the semi-analytical optimization model based on genetic algorithm has good results in our study area;the accuracy of estimated bathymetry in the 0-20 meters shallow water area is accepted.Semi-analytical optimization model based on genetic algorithm solves the problem of the bathymetry estimation without water depth measurement. Generally, our paper provides a new bathymetry estimation method for the sensitive reefs far away from mainland.
La-oxides as tracers for PuO{sub 2} to simulate contaminated aerosol behavior
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, L.C.; Newton, G.J.; Cronenberg, A.W.
1994-04-01
An analytical and experimental study was performed on the use of lanthanide oxides (La-oxides) as surrogates for plutonium oxides (PuO{sub 2}) during simulated buried waste retrieval. This study determined how well the La-oxides move compared to PuO{sub 2} in aerosolized soils during retrieval scenarios. As part of the analytical study, physical properties of La-oxides and PuO{sub 2}, such as molecular diameter, diffusivity, density, and molecular weight are compared. In addition, an experimental study was performed in which Idaho National Engineering Laboratory (INEL) soil, INEL soil with lanthanides, and INEL soil with plutonium were aerosolized and collected in filters. Comparison ofmore » particle size distribution parameters from this experimental study show similarity between INEL soil, INEL soil with lanthanides, and INEL soil with plutonium.« less
Post-standardization of routine creatinine assays: are they suitable for clinical applications.
Jassam, Nuthar; Weykamp, Cas; Thomas, Annette; Secchiero, Sandra; Sciacovelli, Laura; Plebani, Mario; Thelen, Marc; Cobbaert, Christa; Perich, Carmen; Ricós, Carmen; Paula, Faria A; Barth, Julian H
2017-05-01
Introduction Reliable serum creatinine measurements are of vital importance for the correct classification of chronic kidney disease and early identification of kidney injury. The National Kidney Disease Education Programme working group and other groups have defined clinically acceptable analytical limits for creatinine methods. The aim of this study was to re-evaluate the performance of routine creatinine methods in the light of these defined limits so as to assess their suitability for clinical practice. Method In collaboration with the Dutch External Quality Assurance scheme, six frozen commutable samples, with a creatinine concentration ranging from 80 to 239 μmol/L and traceable to isotope dilution mass spectrometry, were circulated to 91 laboratories in four European countries for creatinine measurement and estimated glomerular filtration rate calculation. Two out of the six samples were spiked with glucose to give high and low final concentrations of glucose. Results Results from 89 laboratories were analysed for bias, imprecision (%CV) for each creatinine assay and total error for estimated glomerular filtration rate. The participating laboratories used analytical instruments from four manufacturers; Abbott, Beckman, Roche and Siemens. All enzymatic methods in this study complied with the National Kidney Disease Education Programme working group recommended limits of bias of 5% above a creatinine concentration of 100 μmol/L. They also did not show any evidence of interference from glucose. In addition, they also showed compliance with the clinically recommended %CV of ≤4% across the analytical range. In contrast, the Jaffe methods showed variable performance with regard to the interference of glucose and unsatisfactory bias and precision. Conclusion Jaffe-based creatinine methods still exhibit considerable analytical variability in terms of bias, imprecision and lack of specificity, and this variability brings into question their clinical utility. We believe that clinical laboratories and manufacturers should work together to phase out the use of relatively non-specific Jaffe methods and replace them with more specific methods that are enzyme based.
Analytical Study on Flight Performance of a RP Laser Launcher
NASA Astrophysics Data System (ADS)
Katsurayama, H.; Ushio, M.; Komurasaki, K.; Arakawa, Y.
2005-04-01
An air-breathing RP Laser Launcher has been proposed as the alternative to conventional chemical launch systems. This paper analytically examines the feasibility of SSTO system powered by RP lasers. The trajectory from the ground to the geosynchronous orbit is computed and the launch cost including laser-base development is estimated. The engine performance is evaluated by CFD computations and a cycle analysis. The results show that the beam power of 2.3MW per unit initial vehicle mass is optimum to reach a geo-synchronous transfer orbit, and 3,000 launches are necessary to redeem the cost for laser transmitter.
Q-controlled amplitude modulation atomic force microscopy in liquids: An analysis
NASA Astrophysics Data System (ADS)
Hölscher, H.; Schwarz, U. D.
2006-08-01
An analysis of amplitude modulation atomic force microscopy in liquids is presented with respect to the application of the Q-Control technique. The equation of motion is solved by numerical and analytic methods with and without Q-Control in the presence of a simple model interaction force adequate for many liquid environments. In addition, the authors give an explicit analytical formula for the tip-sample indentation showing that higher Q factors reduce the tip-sample force. It is found that Q-Control suppresses unwanted deformations of the sample surface, leading to the enhanced image quality reported in several experimental studies.
Analytical studies of the Space Shuttle orbiter nose-gear tire
NASA Technical Reports Server (NTRS)
Noor, Ahmed K.; Tanner, John A.; Peters, Jeanne M.; Robinson, Martha P.
1991-01-01
A computational procedure is presented for evaluating the analytic sensitivity derivatives of the tire response with respect to material and geometrical properties of the tire. The tire is modeled by using a two-dimensional laminated anisotropic shell theory with the effects of variation in material and geometric parameters included. The computational procedure is applied to the case of the Space Shuttle orbiter nose-gear tire subjected to uniform inflation pressure. Numerical results are presented which show the sensitivity of the different tire response quantities to variations in the material characteristics of both the cord and rubber.
Theoretical Assessment of Compressibility Factor of Gases by Using Second Virial Coefficient
NASA Astrophysics Data System (ADS)
Mamedov, Bahtiyar A.; Somuncu, Elif; Askerov, Iskender M.
2018-01-01
We present a new analytical approximation for determining the compressibility factor of real gases at various temperature values. This algorithm is suitable for the accurate evaluation of the compressibility factor using the second virial coefficient with a Lennard-Jones (12-6) potential. Numerical examples are presented for the gases H2, N2, He, CO2, CH4 and air, and the results are compared with other studies in the literature. Our results showed good agreement with the data in the literature. The consistency of the results demonstrates the effectiveness of our analytical approximation for real gases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zúñiga-Segundo, Arturo; Juárez-Amaro, Raúl; Aguilar-Loreto, Omar
We study the atom–field interaction when the field is in a mixture of coherent states. We show that in this case it is possible to calculate analytically the field entropy for times of the order of twice the collapse time. Such analytical results are done with the help of numerical analysis. We also give an expression in terms of Chebyshev polynomials for power of density matrices. - Highlights: • We calculate the field entropy for times of the order of twice the collapse time. • We give a relation between powers of the density matrices of the subsystems. • Entropymore » operators for both subsystems are obtained.« less
NASA Astrophysics Data System (ADS)
Lin, Ji; Wang, Hou
2013-07-01
We use the classical Lie-group method to study the evolution equation describing a photovoltaic-photorefractive media with the effects of diffusion process and the external electric field. We reduce it to some similarity equations firstly, and then obtain some analytically exact solutions including the soliton solution, the exponential solution and the oscillatory solution. We also obtain the numeric solitons from these similarity equations. Moreover, We show theoretically that these solutions have two types of trajectories. One type is a straight line. The other is a parabolic curve, which indicates these solitons have self-deflection.
Remote measurements of water pollution with a lidar polarimeter
NASA Technical Reports Server (NTRS)
Sheives, T. C.; Rouse, J. W., Jr.; Mayo, W. T., Jr.
1974-01-01
This paper examines a dual polarization laser backscatter system as a method for remote measurements of certain water quality parameters. Analytical models for describing the backscatter from turbid water and oil on turbid water are presented and compared with experimental data. Laser backscatter field measurements from natural waterways are presented and compared with simultaneous ground observations of the water quality parameters: turbidity, suspended solids, and transmittance. The results of this study show that the analytical models appear valid and that the sensor investigated is applicable to remote measurements of these water quality parameters and oil spills on water.-
Zhang, Dandan; Lei, Tianli; Lv, Chongning; Zhao, Huimin; Xu, Haiyan; Lu, Jincai
2017-02-15
The rhizome of Anemone raddeana Regel, a Traditional Chinese Medicine (TCM) which has a robust history treating rheumatism and neuralgia. The total secondary saponin (TSS) from it has demonstrated antitumor activity. In this study, a rapid and validated LC-MS/MS method was developed to simultaneously determine the active compounds (Hederacolchiside A1 and Eleutheroside K). Analytes were separated on a reverse-phase C18 column with acetonitrile-water (5mmol/L ammonium acetate) as the mobile phase. This assay showed acceptable linearity (r>0.99) over the concentration range 5-1000 nmol/L for two analytes. The intra- and inter-day precision was within 8.06% and accuracy was ranged from -3.16% to 3.34% for two analytes. The mean extraction recoveries of analytes and IS from rat plasma were all more than 76.0%. Under the developed analytical conditions, the obtained values of main pharmacokinetic parameters (C max and AUC 0-t ) indicated that the pure compounds were more efficient than the TSS extract in Hederacolchiside A1 and Eleutheroside K absorption. In addition, pharmacokinetic studies of two individual compounds demonstrated their poor oral absorption in rat ( a F%, 0.019-1.521). In the study of absorption and transportation of Hederacolchiside A1 and Eleutheroside K in Caco-2 cell monolayer model, the uptake permeability was in 10 -6 cm/sec range suggesting poor absorption, which confirmed the previous pharmacokinetic profiles in vivo. Interestingly, the uptake ratio of them declined significantly when treated with phloridzin (SGLT1 inhibitor). It indicated that the absorption of Hederacolchiside A1 in intestine was mainly through positive transport and SGLT1 might participate in its active absorption. Copyright © 2017 Elsevier B.V. All rights reserved.
Facilitating an L2 Book Club: A Conversation-Analytic Study of Task Management
ERIC Educational Resources Information Center
Ro, Eunseok
2018-01-01
This study employs conversation analysis to examine a facilitator's interactional practices in the post-expansion phase of students' presentations in the context of a book club for second language learning. The analysis shows how the facilitator establishes intersubjectivity with regard to the ongoing task and manages students' task performance.…
Computer-Based Instruction and Health Professions Education: A Meta-Analysis of Outcomes.
ERIC Educational Resources Information Center
Cohen, Peter A.; Dacanay, Lakshmi S.
1992-01-01
The meta-analytic techniques of G. V. Glass were used to statistically integrate findings from 47 comparative studies on computer-based instruction (CBI) in health professions education. A clear majority of the studies favored CBI over conventional methods of instruction. Results show higher-order applications of computers to be especially…
Learning about Workplace Learning and Expertise from Jack: A Discourse Analytic Study
ERIC Educational Resources Information Center
Lee, Yew-Jin; Roth, Wolff-Michael
2006-01-01
Purpose: The purpose of this paper is to highlight some methodological problems concerning the neglect of participants' voices by workplace ethnographers and neglect of the highly interactional and co-constructive nature of research interviewing. The study aims to use discourse analysis, to show the phenomena of workplace learning and expertise to…
NASA Astrophysics Data System (ADS)
Adedokun, Omolola A.; Liu, Jia; Parker, Loran Carleton; Burgess, Wilella
2015-02-01
Although virtual field trips are becoming popular, there are few empirical studies of their impacts on student outcomes. This study reports on a meta-analytic evaluation of the impact of a virtual field trip on student perceptions of scientists. Specifically, the study examined the summary effect of zipTrips broadcasts on evaluation participants' perceptions of scientists, as well as the moderating effect of program type on program impact. The results showed statistically significant effect of each broadcast, as well as statistically significant summary (combined) effect of zipTrips on evaluation participants' perceptions of scientists. Results of the moderation analysis showed that the effect was greater for the students that participated in the evaluation of the 8th grade broadcasts, providing additional insight into the role of program variation in predicting differential program impact. This study illustrates how meta-analysis, a methodology that should be of interest to STEM education researchers and evaluation practitioners, can be used to summarize the effects of multiple offerings of the same program. Other implications for STEM educators are discussed.
Fasoula, S; Zisi, Ch; Sampsonidis, I; Virgiliou, Ch; Theodoridis, G; Gika, H; Nikitas, P; Pappa-Louisi, A
2015-03-27
In the present study a series of 45 metabolite standards belonging to four chemically similar metabolite classes (sugars, amino acids, nucleosides and nucleobases, and amines) was subjected to LC analysis on three HILIC columns under 21 different gradient conditions with the aim to explore whether the retention properties of these analytes are determined from the chemical group they belong. Two multivariate techniques, principal component analysis (PCA) and discriminant analysis (DA), were used for statistical evaluation of the chromatographic data and extraction similarities between chemically related compounds. The total variance explained by the first two principal components of PCA was found to be about 98%, whereas both statistical analyses indicated that all analytes are successfully grouped in four clusters of chemical structure based on the retention obtained in four or at least three chromatographic runs, which, however should be performed on two different HILIC columns. Moreover, leave-one-out cross-validation of the above retention data set showed that the chemical group in which an analyte belongs can be 95.6% correctly predicted when the analyte is subjected to LC analysis under the same four or three experimental conditions as the all set of analytes was run beforehand. That, in turn, may assist with disambiguation of analyte identification in complex biological extracts. Copyright © 2015 Elsevier B.V. All rights reserved.
[Artistic creativity in the light of Jungian analytical psychology].
Trixler, Mátyás; Gáti, Agnes; Tényi, Tamás
2010-01-01
C.G. Jung's analytical psychology points at important issues in the psychological understanding of creativity. The theories of the Collective Unconscious and the Archetypes contributed to important discoveries in the interpretation of artistic creativity. Jung was concerned to show the relevance of Analytical Psychology to the understanding of European Modernism. Our paper deals with a short Jungian interpretation of Csontvary's art, too.
Steuer, Andrea E; Forss, Anna-Maria; Dally, Annika M; Kraemer, Thomas
2014-11-01
In the context of driving under the influence of drugs (DUID), not only common drugs of abuse may have an influence, but also medications with similar mechanisms of action. Simultaneous quantification of a variety of drugs and medications relevant in this context allows faster and more effective analyses. Therefore, multi-analyte approaches have gained more and more popularity in recent years. Usually, calibration curves for such procedures contain a mixture of all analytes, which might lead to mutual interferences. In this study we investigated whether the use of such mixtures leads to reliable results for authentic samples containing only one or two analytes. Five hundred microliters of whole blood were extracted by routine solid-phase extraction (SPE, HCX). Analysis was performed on an ABSciex 3200 QTrap instrument with ESI+ in scheduled MRM mode. The method was fully validated according to international guidelines including selectivity, recovery, matrix effects, accuracy and precision, stabilities, and limit of quantification. The selected SPE provided recoveries >60% for all analytes except 6-monoacetylmorphine (MAM) with coefficients of variation (CV) below 15% or 20% for quality controls (QC) LOW and HIGH, respectively. Ion suppression >30% was found for benzoylecgonine, hydrocodone, hydromorphone, MDA, oxycodone, and oxymorphone at QC LOW, however CVs were always below 10% (n=6 different whole blood samples). Accuracy and precision criteria were fulfilled for all analytes except for MAM. Systematic investigation of accuracy determined for QC MED in a multi-analyte mixture compared to samples containing only single analytes revealed no relevant differences for any analyte, indicating that a multi-analyte calibration is suitable for the presented method. Comparison of approximately 60 samples to a former GC-MS method showed good correlation. The newly validated method was successfully applied to more than 1600 routine samples and 3 proficiency tests. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Choi, S.; Kim, C.; Park, C.; Kim, H.
2013-12-01
The North Fiji Basin is belong to one of the youngest basins of back-arc basins in the southwest Pacific (from 12 Ma ago). We performed the marine magnetic and the bathymetry survey in the North Fiji Basin for finding the submarine hydrothermal deposits in April 2012. We acquired magnetic and bathymetry datasets by using Multi-Beam Echo Sounder EM120 (Kongsberg Co.) and Overhouser Proton Magnetometer SeaSPY (Marine Magnetics Co.). We conducted the data processing to obtain detailed seabed topography, magnetic anomaly, reduce to the pole(RTP), analytic signal and magnetization. The study areas composed of the two areas(KF-1(longitude : 173.5 ~ 173.7 and latitude : -16.2 ~ -16.5) and KF-3(longitude : 173.4 ~ 173.6 and latitude : -18.7 ~ -19.1)) in Central Spreading Ridge(CSR) and one area(KF-2(longitude : 173.7 ~ 174 and latitude : -16.8 ~ -17.2)) in Triple Junction(TJ). The seabed topography of KF-1 existed thin horst in two grabens that trends NW-SE direction. The magnetic properties of KF-1 showed high magnetic anomalies in center part and magnetic lineament structure of trending E-W direction. In the magnetization distribution of KF-1, the low magnetization zone matches well with a strong analytic signal in the northeastern part. KF-2 area has TJ. The seabed topography formed like Y-shape and showed a high feature in the center of TJ. The magnetic properties of KF-2 displayed high magnetic anomalies in N-S spreading ridge center and northwestern part. In the magnetization distribution of KF-2, the low magnetization zone matches well with a strong analytic signal in the northeastern part. The seabed topography of KF-3 presented a flat and high topography like dome structure at center axis and some seamounts scattered around the axis. The magnetic properties of KF-3 showed high magnetic anomalies in N-S spreading ridge center part. In the magnetization of KF-2, the low magnetization zone mismatches to strong analytic signal in this area. The difference of KF-3 between the low magnetization zones and the analytic signals is considered that the submarine magnetic strength of KF-3 is lower than that of KF-1 and KF-2. The spreading ridges of the study areas showed common Central Anomaly Magnetization Highs (CAMH). As a whole, the previous studies on the structure of this study area (Auzende et al, 1990) support our results of the magnetic properties (Magnetic Anomaly and RTP). We can expect to have the better results by comparing with the other study like geophysics (seismic), geology, and geochemistry in this area. Reference Auzende, J.M., and 29 others, Active Spreading and Hydrothermalism in North Fiji Basin(SW Pacific). Results of Japanese French Cruise Kaiyo 87, Marine Geophysical Researches., 12, 269-283, 1990.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillen, David S.
Analysis activities for Nonproliferation and Arms Control verification require the use of many types of data. Tabular structured data, such as Excel spreadsheets and relational databases, have traditionally been used for data mining activities, where specific queries are issued against data to look for matching results. The application of visual analytics tools to structured data enables further exploration of datasets to promote discovery of previously unknown results. This paper discusses the application of a specific visual analytics tool to datasets related to the field of Arms Control and Nonproliferation to promote the use of visual analytics more broadly in thismore » domain. Visual analytics focuses on analytical reasoning facilitated by interactive visual interfaces (Wong and Thomas 2004). It promotes exploratory analysis of data, and complements data mining technologies where known patterns can be mined for. Also with a human in the loop, they can bring in domain knowledge and subject matter expertise. Visual analytics has not widely been applied to this domain. In this paper, we will focus on one type of data: structured data, and show the results of applying a specific visual analytics tool to answer questions in the Arms Control and Nonproliferation domain. We chose to use the T.Rex tool, a visual analytics tool developed at PNNL, which uses a variety of visual exploration patterns to discover relationships in structured datasets, including a facet view, graph view, matrix view, and timeline view. The facet view enables discovery of relationships between categorical information, such as countries and locations. The graph tool visualizes node-link relationship patterns, such as the flow of materials being shipped between parties. The matrix visualization shows highly correlated categories of information. The timeline view shows temporal patterns in data. In this paper, we will use T.Rex with two different datasets to demonstrate how interactive exploration of the data can aid an analyst with arms control and nonproliferation verification activities. Using a dataset from PIERS (PIERS 2014), we will show how container shipment imports and exports can aid an analyst in understanding the shipping patterns between two countries. We will also use T.Rex to examine a collection of research publications from the IAEA International Nuclear Information System (IAEA 2014) to discover collaborations of concern. We hope this paper will encourage the use of visual analytics structured data analytics in the field of nonproliferation and arms control verification. Our paper outlines some of the challenges that exist before broad adoption of these kinds of tools can occur and offers next steps to overcome these challenges.« less
Evaluation of performance and maximum length of continuous decks in bridges : part 2.
DOT National Transportation Integrated Search
2012-08-01
Field experimental measurements and analytical studies showed that the link-slab reinforcement : experiences almost no axial load due to thermal and gravity loading. One of the fundamental : reasons for the low loads in the link-slab reinforcement is...
Promoting Creative Tension within Collaborative Writing Groups.
ERIC Educational Resources Information Center
Ewald, Helen Rothschild; MacCallum, Virginia
1990-01-01
Describes a collaborative writing assignment which features a series of interconnected business messages arising out of a case study and including inhouse memos and an analytical report. Shows how the design of a collaborative writing assignment can foster creative rather than debilitative tension. (RS)
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), FIRST FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), FIRST FLOOR SHOWING SAMPLE CORRIDORS AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL FACILITIES LAB, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051979. ALTERNATE ID NUMBER CPP-E-1979. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Fujimoto, Kayo; Unger, Jennifer B.; Valente, Thomas W.
2011-01-01
Using a network analytic framework, this study introduces a new method to measure peer influence based on adolescents’ affiliations or two-mode social network data. Exposure based on affiliations is referred to as the “affiliation exposure model.” This study demonstrates the methodology using data on young adolescent smoking being influenced by joint participation in school-based organized sports activities with smokers. The analytic sample consisted of 1260 American adolescents from age 10 to 13 in middle schools, and the results of the longitudinal regression analyses showed that adolescents were more likely to smoke as they were increasingly exposed to teammates who smoke. This study illustrates the importance of peer influence via affiliation through team sports. PMID:22313152
An analytical and experimental investigation of sandwich composites subjected to low-velocity impact
NASA Astrophysics Data System (ADS)
Anderson, Todd Alan
1999-12-01
This study involves an experimental and analytical investigation of low-velocity impact phenomenon in sandwich composite structures. The analytical solution of a three-dimensional finite-geometry multi-layer specially orthotropic panel subjected to static and transient transverse loading cases is presented. The governing equations of the static and dynamic formulations are derived from Reissner's functional and solved by enforcing the continuity of traction and displacement components between adjacent layers. For the dynamic loading case, the governing equations are solved by applying Fourier or Laplace transformation in time. Additionally, the static solution is extended to solve the contact problem between the sandwich laminate and a rigid sphere. An iterative method is employed to determine the sphere's unknown contact area and pressure distribution. A failure criterion is then applied to the sandwich laminate's stress and strain field to predict impact damage. The analytical accuracy of the present study is verified through comparisons with finite element models, other analyses, and through experimentation. Low-velocity impact tests were conducted to characterize the type and extent of the damage observed in a variety of sandwich configurations with graphite/epoxy face sheets and foam or honeycomb cores. Correlation of the residual indentation and cross-sectional views of the impacted specimens provides a criterion for the extent of damage. Quasi-static indentation tests are also performed and show excellent agreement when compared with the analytical predictions. Finally, piezoelectric polyvinylidene fluoride (PVF2) film sensors are found to be effective in detecting low-velocity impact.
Dependence of yield of nuclear track-biosensors on track radius and analyte concentration
NASA Astrophysics Data System (ADS)
García-Arellano, H.; Muñoz H., G.; Fink, D.; Vacik, J.; Hnatowicz, V.; Alfonta, L.; Kiv, A.
2018-04-01
In swift heavy ion track-based polymeric biosensor foils with incorporated enzymes one exploits the correlation between the analyte concentration and the sensor current, via the enrichment of charged enzymatic reaction products in the track's confinement. Here we study the influence of the etched track radius on the biosensor's efficiency. These sensors are analyte-specific only if both the track radii and the analyte concentration exceed certain threshold values of ∼15 nm and ∼10-6 M (for glucose sensing), respectively. Below these limits the sensor signal stems un-specifically from any charge carrier. In its proper working regime, the inner track walls are smoothly covered by enzymes and the efficiency is practically radius independent. Theory shows that the measured current should be slightly sub-proportional to the analyte concentration; the measurements roughly reconfirm this. Narrower tracks (∼5-15 nm radius) with reduced enzyme coverage lead to decreasing efficiency. Tiny signals visible when the tracks are etched to effective radii between 0 and ∼5 nm are tentatively ascribed to enzymes bonded to surface-near nano-cracks in the polymer foil, resulting from its degradation due to aging, rather than to the tracks. Precondition for this study was the accurate determination of the etched track radii, which is possible only by a nanofluidic approach. This holds to some extent even for enzyme-covered tracks, though in this case most of the wall charges are compensated by enzyme bonding.
Park, In-Sun; Park, Jae-Woo
2011-01-30
Total petroleum hydrocarbon (TPH) is an important environmental contaminant that is toxic to human and environmental receptors. However, human health risk assessment for petroleum, oil, and lubricant (POL)-contaminated sites is especially challenging because TPH is not a single compound, but rather a mixture of numerous substances. To address this concern, this study recommends a new human health risk assessment strategy for POL-contaminated sites. The strategy is based on a newly modified TPH fractionation method and includes an improved analytical protocol. The proposed TPH fractionation method is composed of ten fractions (e.g., aliphatic and aromatic EC8-10, EC10-12, EC12-16, EC16-22 and EC22-40). Physicochemical properties and toxicity values of each fraction were newly defined in this study. The stepwise ultrasonication-based analytical process was established to measure TPH fractions. Analytical results were compared with those from the TPH Criteria Working Group (TPHCWG) Direct Method. Better analytical efficiencies in TPH, aliphatic, and aromatic fractions were achieved when contaminated soil samples were analyzed with the new analytical protocol. Finally, a human health risk assessment was performed based on the developed tiered risk assessment framework. Results showed that a detailed quantitative risk assessment should be conducted to determine scientifically and economically appropriate cleanup target levels, although the phase II process is useful for determining the potency of human health risks posed by POL-contamination. Copyright © 2010 Elsevier B.V. All rights reserved.
Holographic conductivity of holographic superconductors with higher-order corrections
NASA Astrophysics Data System (ADS)
Sheykhi, Ahmad; Ghazanfari, Afsoon; Dehyadegari, Amin
2018-02-01
We analytically and numerically disclose the effects of the higher-order correction terms in the gravity and in the gauge field on the properties of s-wave holographic superconductors. On the gravity side, we consider the higher curvature Gauss-Bonnet corrections and on the gauge field side, we add a quadratic correction term to the Maxwell Lagrangian. We show that, for this system, one can still obtain an analytical relation between the critical temperature and the charge density. We also calculate the critical exponent and the condensation value both analytically and numerically. We use a variational method, based on the Sturm-Liouville eigenvalue problem for our analytical study, as well as a numerical shooting method in order to compare with our analytical results. For a fixed value of the Gauss-Bonnet parameter, we observe that the critical temperature decreases with increasing the nonlinearity of the gauge field. This implies that the nonlinear correction term to the Maxwell electrodynamics makes the condensation harder. We also study the holographic conductivity of the system and disclose the effects of the Gauss-Bonnet and nonlinear parameters α and b on the superconducting gap. We observe that, for various values of α and b, the real part of the conductivity is proportional to the frequency per temperature, ω /T, as the frequency is large enough. Besides, the conductivity has a minimum in the imaginary part which is shifted toward greater frequency with decreasing temperature.
NASA Astrophysics Data System (ADS)
Usta, Metin; Tufan, Mustafa Çağatay; Aydın, Güral; Bozkurt, Ahmet
2018-07-01
In this study, we have performed the calculations stopping power, depth dose, and range verification for proton beams using dielectric and Bethe-Bloch theories and FLUKA, Geant4 and MCNPX Monte Carlo codes. In the framework, as analytical studies, Drude model was applied for dielectric theory and effective charge approach with Roothaan-Hartree-Fock charge densities was used in Bethe theory. In the simulations different setup parameters were selected to evaluate the performance of three distinct Monte Carlo codes. The lung and breast tissues were investigated are considered to be related to the most common types of cancer throughout the world. The results were compared with each other and the available data in literature. In addition, the obtained results were verified with prompt gamma range data. In both stopping power values and depth-dose distributions, it was found that the Monte Carlo values give better results compared with the analytical ones while the results that agree best with ICRU data in terms of stopping power are those of the effective charge approach between the analytical methods and of the FLUKA code among the MC packages. In the depth dose distributions of the examined tissues, although the Bragg curves for Monte Carlo almost overlap, the analytical ones show significant deviations that become more pronounce with increasing energy. Verifications with the results of prompt gamma photons were attempted for 100-200 MeV protons which are regarded important for proton therapy. The analytical results are within 2%-5% and the Monte Carlo values are within 0%-2% as compared with those of the prompt gammas.
STOL aircraft transient ground effects. Part 1: Fundamental analytical study
NASA Technical Reports Server (NTRS)
Goldhammer, M. I.; Crowder, J. P.; Smyth, D. N.
1975-01-01
The first phases of a fundamental analytical study of STOL ground effects were presented. Ground effects were studied in two dimensions to establish the importance of nonlinear effects, to examine transient aspects of ascent and descent near the ground, and to study the modelling of the jet impingement on the ground. Powered lift system effects were treated using the jet-flap analogy. The status of a three-dimensional jet-wing ground effect method was presented. It was shown, for two-dimensional unblown airfoils, that the transient effects are small and are primarily due to airfoil/freestream/ground orientation rather than to unsteady effects. The three-dimensional study showed phenomena similar to the two-dimensional results. For unblown wings, the wing/freestream/ground orientation effects were shown to be of the same order of magnitude as for unblown airfoils. This may be used to study the nonplanar, nonlinear, jet-wing ground effect.
Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.
Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo
2018-02-23
The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.
Nonlinear whistler wave model for lion roars in the Earth's magnetosheath
NASA Astrophysics Data System (ADS)
Dwivedi, N. K.; Singh, S.
2017-09-01
In the present study, we construct a nonlinear whistler wave model to explain the magnetic field spectra observed for lion roars in the Earth's magnetosheath region. We use two-fluid theory and semi-analytical approach to derive the dynamical equation of whistler wave propagating along the ambient magnetic field. We examine the magnetic field localization of parallel propagating whistler wave in the intermediate beta plasma applicable to the Earth's magnetosheath. In addition, we investigate spectral features of the magnetic field fluctuations and the spectral slope value. The magnetic field spectrum obtained by semi-analytical approach shows a spectral break point and becomes steeper at higher wave numbers. The observations of IMP 6 plasma waves and magnetometer experiment reveal the existence of short period magnetic field fluctuations in the magnetosheath. The observation shows the broadband spectrum with a spectral slope of -4.5 superimposed with a narrow band peak. The broadband fluctuations appear due to the energy cascades attributed by low-frequency magnetohydrodynamic modes, whereas, a narrow band peak is observed due to the short period lion roars bursts. The energy spectrum predicted by the present theoretical model shows a similar broadband spectrum in the wave number domain with a spectral slope of -3.2, however, it does not show any narrow band peak. Further, we present a comparison between theoretical energy spectrum and the observed spectral slope in the frequency domain. The present semi-analytical model provides exposure to the whistler wave turbulence in the Earth's magnetosheath.
NASA Astrophysics Data System (ADS)
Malovichko, M.; Khokhlov, N.; Yavich, N.; Zhdanov, M.
2017-10-01
Over the recent decades, a number of fast approximate solutions of Lippmann-Schwinger equation, which are more accurate than classic Born and Rytov approximations, were proposed in the field of electromagnetic modeling. Those developments could be naturally extended to acoustic and elastic fields; however, until recently, they were almost unknown in seismology. This paper presents several solutions of this kind applied to acoustic modeling for both lossy and lossless media. We evaluated the numerical merits of those methods and provide an estimation of their numerical complexity. In our numerical realization we use the matrix-free implementation of the corresponding integral operator. We study the accuracy of those approximate solutions and demonstrate, that the quasi-analytical approximation is more accurate, than the Born approximation. Further, we apply the quasi-analytical approximation to the solution of the inverse problem. It is demonstrated that, this approach improves the estimation of the data gradient, comparing to the Born approximation. The developed inversion algorithm is based on the conjugate-gradient type optimization. Numerical model study demonstrates that the quasi-analytical solution significantly reduces computation time of the seismic full-waveform inversion. We also show how the quasi-analytical approximation can be extended to the case of elastic wavefield.
Phonon dispersion on Ag (100) surface: A modified analytic embedded atom method study
NASA Astrophysics Data System (ADS)
Xiao-Jun, Zhang; Chang-Le, Chen
2016-01-01
Within the harmonic approximation, the analytic expression of the dynamical matrix is derived based on the modified analytic embedded atom method (MAEAM) and the dynamics theory of surface lattice. The surface phonon dispersions along three major symmetry directions , and X¯M¯ are calculated for the clean Ag (100) surface by using our derived formulas. We then discuss the polarization and localization of surface modes at points X¯ and M¯ by plotting the squared polarization vectors as a function of the layer index. The phonon frequencies of the surface modes calculated by MAEAM are compared with the available experimental and other theoretical data. It is found that the present results are generally in agreement with the referenced experimental or theoretical results, with a maximum deviation of 10.4%. The agreement shows that the modified analytic embedded atom method is a reasonable many-body potential model to quickly describe the surface lattice vibration. It also lays a significant foundation for studying the surface lattice vibration in other metals. Project supported by the National Natural Science Foundation of China (Grant Nos. 61471301 and 61078057), the Scientific Research Program Funded by Shaanxi Provincial Education Department, China (Grant No. 14JK1301), and the Specialized Research Fund for the Doctoral Program of Higher Education, China (Grant No. 20126102110045).
Scattering of In-Plane Waves by Elastic Wedges
NASA Astrophysics Data System (ADS)
Mohammadi, K.; Asimaki, D.; Fradkin, L.
2014-12-01
The scattering of seismic waves by elastic wedges has been a topic of interest in seismology and geophysics for many decades. Analytical, semi-analytical, experimental and numerical studies on idealized wedges have provided insight into the seismic behavior of continental margins, mountain roots and crustal discontinuities. Published results, however, have almost exclusively focused on incident Rayleigh waves and out-of-plane body (SH) waves. Complementing the existing body of work, we here present results from our study on the response of elastic wedges to incident P or SV waves, an idealized problem that can provide valuable insight to the understanding and parameterization of topographic amplification of seismic ground motion. We first show our earlier work on explicit finite difference simulations of SV-wave scattering by elastic wedges over a wide range of internal angles. We next present a semi-analytical solution that we developed using the approach proposed by Gautesen, to describe the scattered wavefield in the immediate vicinity of the wedge's tip (near-field). We use the semi-analytical solution to validate the numerical analyses, and improve resolution of the amplification factor at the wedge vertex that spikes when the internal wedge angle approaches the critical angle of incidence.
A Semi-Analytical Method for the PDFs of A Ship Rolling in Random Oblique Waves
NASA Astrophysics Data System (ADS)
Liu, Li-qin; Liu, Ya-liu; Xu, Wan-hai; Li, Yan; Tang, You-gang
2018-03-01
The PDFs (probability density functions) and probability of a ship rolling under the random parametric and forced excitations were studied by a semi-analytical method. The rolling motion equation of the ship in random oblique waves was established. The righting arm obtained by the numerical simulation was approximately fitted by an analytical function. The irregular waves were decomposed into two Gauss stationary random processes, and the CARMA (2, 1) model was used to fit the spectral density function of parametric and forced excitations. The stochastic energy envelope averaging method was used to solve the PDFs and the probability. The validity of the semi-analytical method was verified by the Monte Carlo method. The C11 ship was taken as an example, and the influences of the system parameters on the PDFs and probability were analyzed. The results show that the probability of ship rolling is affected by the characteristic wave height, wave length, and the heading angle. In order to provide proper advice for the ship's manoeuvring, the parametric excitations should be considered appropriately when the ship navigates in the oblique seas.
Electrospun polyvinyl alcohol ultra-thin layer chromatography of amino acids.
Lu, Tian; Olesik, Susan V
2013-01-01
Electrospun polyvinyl alcohol (PVA) ultrathin layer chromatographic (UTLC) plates were fabricated using in situ crosslinking electrospinning technique. The value of these ULTC plates were characterized using the separation of fluorescein isothiocyanate (FITC) labeled amino acids and the separation of amino acids followed visualization using ninhydrin. The in situ crosslinked electrospun PVA plates showed enhanced stability in water and were stable when used for the UTLC study. The selectivity of FITC labeled amino acids on PVA plate was compared with that on commercial Si-Gel plate. The efficiency of the separation varied with analyte concentration, size of capillary analyte applicator, analyte volume, and mat thickness. The concentration of 7mM or less, 50μm i.d. capillary applicator, minimum volume of analyte solution and three-layered mat provides the best efficiency of FITC-labeled amino acids on PVA UTLC plate. The efficiency on PVA plate was greatly improved compared to the efficiency on Si-Gel HPTLC plate. The hydrolysis products of aspartame in diet coke, aspartic acid and phenylalanine, were also successfully analyzed using PVA-UTLC plate. Copyright © 2012 Elsevier B.V. All rights reserved.
Ungerer, Jacobus P J; Pretorius, Carel J
2014-04-01
Highly-sensitive cardiac troponin (cTn) assays are being introduced into the market. In this study we argue that the classification of cTn assays into sensitive and highly-sensitive is flawed and recommend a more appropriate way to characterize analytical sensitivity of cTn assays. The raw data of 2252 cardiac troponin I (cTnI) tests done in duplicate with a 'sensitive' assay was extracted and used to calculate the cTnI levels in all, including those below the 'limit of detection' (LoD) that were censored. Duplicate results were used to determine analytical imprecision. We show that cTnI can be quantified in all samples including those with levels below the LoD and that the actual margins of error decrease as concentrations approach zero. The dichotomous classification of cTn assays into sensitive and highly-sensitive is theoretically flawed and characterizing analytical sensitivity as a continuous variable based on imprecision at 0 and the 99th percentile cut-off would be more appropriate.
A Multiomics Approach to Identify Genes Associated with Childhood Asthma Risk and Morbidity.
Forno, Erick; Wang, Ting; Yan, Qi; Brehm, John; Acosta-Perez, Edna; Colon-Semidey, Angel; Alvarez, Maria; Boutaoui, Nadia; Cloutier, Michelle M; Alcorn, John F; Canino, Glorisa; Chen, Wei; Celedón, Juan C
2017-10-01
Childhood asthma is a complex disease. In this study, we aim to identify genes associated with childhood asthma through a multiomics "vertical" approach that integrates multiple analytical steps using linear and logistic regression models. In a case-control study of childhood asthma in Puerto Ricans (n = 1,127), we used adjusted linear or logistic regression models to evaluate associations between several analytical steps of omics data, including genome-wide (GW) genotype data, GW methylation, GW expression profiling, cytokine levels, asthma-intermediate phenotypes, and asthma status. At each point, only the top genes/single-nucleotide polymorphisms/probes/cytokines were carried forward for subsequent analysis. In step 1, asthma modified the gene expression-protein level association for 1,645 genes; pathway analysis showed an enrichment of these genes in the cytokine signaling system (n = 269 genes). In steps 2-3, expression levels of 40 genes were associated with intermediate phenotypes (asthma onset age, forced expiratory volume in 1 second, exacerbations, eosinophil counts, and skin test reactivity); of those, methylation of seven genes was also associated with asthma. Of these seven candidate genes, IL5RA was also significant in analytical steps 4-8. We then measured plasma IL-5 receptor α levels, which were associated with asthma age of onset and moderate-severe exacerbations. In addition, in silico database analysis showed that several of our identified IL5RA single-nucleotide polymorphisms are associated with transcription factors related to asthma and atopy. This approach integrates several analytical steps and is able to identify biologically relevant asthma-related genes, such as IL5RA. It differs from other methods that rely on complex statistical models with various assumptions.
SIFT-MS and FA-MS methods for ambient gas phase analysis: developments and applications in the UK.
Smith, David; Španěl, Patrik
2015-04-21
Selected ion flow tube mass spectrometry, SIFT-MS, a relatively new gas/vapour phase analytical method, is derived from the much earlier selected ion flow tube, SIFT, used for the study of gas phase ion-molecule reactions. Both the SIFT and SIFT-MS techniques were conceived and developed in the UK, the former at Birmingham University, the latter at Keele University along with the complementary flowing afterglow mass spectrometry, FA-MS, technique. The focus of this short review is largely to describe the origins, developments and, most importantly, the unique features of SIFT-MS as an analytical tool for ambient analysis and to indicate its growing use to analyse humid air, especially exhaled breath, its unique place as a on-line, real time analytical method and its growing use and applications as a non-invasive diagnostic in clinical diagnosis and therapeutic monitoring, principally within several UK universities and hospitals, and briefly in the wider world. A few case studies are outlined that show the potential of SIFT-MS and FA-MS in the detection and quantification of metabolites in exhaled breath as a step towards recognising pathophysiology indicative of disease and the presence of bacterial and fungal infection of the airways and lungs. Particular cases include the detection of Pseudomonas aeruginosa infection of the airways of patients with cystic fibrosis (SIFT-MS) and the measurement of total body water in patients with chronic kidney disease (FA-MS). The growing exploitation of SIFT-MS in other areas of research and commerce are briefly listed to show the wide utility of this unique UK-developed analytical method, and future prospects and developments are alluded to.
Zhang, Ya; Lucy, Charles A
2014-12-05
In HPLC, injection of solvents that differ from the eluent can result in peak broadening due to solvent strength mismatch or viscous fingering. Broadened, distorted or even split analyte peaks may result. Past studies of this injection-induced peak distortion in reversed phase (RPLC) and hydrophilic interaction (HILIC) liquid chromatography have led to the conclusion that the sample should be injected in the eluent or a weaker solvent. However, there have been no studies of injection-induced peak distortion in ion chromatography (IC). To address this, injection-induced effects were studied for six inorganic anions (F-, Cl-, NO2-, Br-, NO3- and SO4(2-)) on a Dionex AS23 IC column using a HCO3-/CO3(2-) eluent. The VanMiddlesworth-Dorsey injection sensitivity parameter (s) showed that IC of anions has much greater tolerance to the injection matrix (HCO3-/CO3(2-) herein) mismatch than RPLC or HILIC. Even when the injection contained a ten-fold greater concentration of HCO3-/CO3(2-) than the eluent, the peak shapes and separation efficiencies of six analyte ions did not change significantly. At more than ten-fold greater matrix concentrations, analyte anions that elute near the system peak of the matrix were distorted, and in the extreme cases exhibited a small secondary peak on the analyte peak front. These studies better guide the degree of dilution needed prior to IC analysis of anions. Copyright © 2014 Elsevier B.V. All rights reserved.
Garrido, Eva; Camacho-Muñoz, Dolores; Martín, Julia; Santos, Antonio; Santos, Juan Luis; Aparicio, Irene; Alonso, Esteban
2016-12-01
Guadiamar River is located in the southwest of the Iberian Peninsula and connects two protected areas in the South of Spain: Sierra Morena and Doñana National Park. It is sited in an area affected by urban, industrial and agriculture sewage pollution and with tradition on intensive mining activities. Most of the studies performed in this area have been mainly focused on the presence of heavy metals and, until now, little is known about the occurrence of other contaminants such as emerging organic pollutants (EOPs). In this work, an analytical method has been optimized and validated for monitoring of forty-seven EOPs in surface water. The analytical method has been applied to study the distribution and environmental risk of these pollutants in Guadiamar River basin. The analytical method was based on solid-phase extraction and determination by liquid chromatography-triple quadrupole-tandem mass spectrometry. The 60 % of the target compounds were found in the analyzed samples. The highest concentrations were found for two plasticizers (bisphenol A and di(2-ethyhexyl)phthalate, mean concentration up to 930 ng/L) and two pharmaceutical compounds (caffeine (up to 623 ng/L) and salicylic acid (up to 318 ng/L)). This study allowed to evaluate the potential sources (industrial or urban) of the studied compounds and the spatial distribution of their concentrations along the river. Environmental risk assessment showed a major risk on the south of the river, mainly due to discharges of wastewater effluents.
Developmental changes in analytic and holistic processes in face perception
Joseph, Jane E.; DiBartolo, Michelle D.; Bhatt, Ramesh S.
2015-01-01
Although infants demonstrate sensitivity to some kinds of perceptual information in faces, many face capacities continue to develop throughout childhood. One debate is the degree to which children perceive faces analytically versus holistically and how these processes undergo developmental change. In the present study, school-aged children and adults performed a perceptual matching task with upright and inverted face and house pairs that varied in similarity of featural or 2nd order configural information. Holistic processing was operationalized as the degree of serial processing when discriminating faces and houses [i.e., increased reaction time (RT), as more features or spacing relations were shared between stimuli]. Analytical processing was operationalized as the degree of parallel processing (or no change in RT as a function of greater similarity of features or spatial relations). Adults showed the most evidence for holistic processing (most strongly for 2nd order faces) and holistic processing was weaker for inverted faces and houses. Younger children (6–8 years), in contrast, showed analytical processing across all experimental manipulations. Older children (9–11 years) showed an intermediate pattern with a trend toward holistic processing of 2nd order faces like adults, but parallel processing in other experimental conditions like younger children. These findings indicate that holistic face representations emerge around 10 years of age. In adults both 2nd order and featural information are incorporated into holistic representations, whereas older children only incorporate 2nd order information. Holistic processing was not evident in younger children. Hence, the development of holistic face representations relies on 2nd order processing initially then incorporates featural information by adulthood. PMID:26300838
Nondiffracting wave beams in non-Hermitian Glauber-Fock lattice
NASA Astrophysics Data System (ADS)
Oztas, Z.
2018-05-01
We theoretically study non-Hermitian Glauber-Fock lattice with nonuniform hopping. We show how to engineer this lattice to get nondiffracting wave beams and find an exact analytical solution to nondiffracting localized waves. The exceptional points in the energy spectrum are also analyzed.
Structural Acoustic Physics Based Modeling of Curved Composite Shells
2017-09-19
Results show that the finite element computational models accurately match analytical calculations, and that the composite material studied in this...products. 15. SUBJECT TERMS Finite Element Analysis, Structural Acoustics, Fiber-Reinforced Composites, Physics-Based Modeling 16. SECURITY...2 4 FINITE ELEMENT MODEL DESCRIPTION
What is the right formalism to search for resonances?
NASA Astrophysics Data System (ADS)
Mikhasenko, M.; Pilloni, A.; Nys, J.; Albaladejo, M.; Fernández-Ramírez, C.; Jackura, A.; Mathieu, V.; Sherrill, N.; Skwarnicki, T.; Szczepaniak, A. P.
2018-03-01
Hadron decay chains constitute one of the main sources of information on the QCD spectrum. We discuss the differences between several partial wave analysis formalisms used in the literature to build the amplitudes. We match the helicity amplitudes to the covariant tensor basis. Hereby, we pay attention to the analytical properties of the amplitudes and separate singularities of kinematical and dynamical nature. We study the analytical properties of the spin-orbit (LS) formalism, and some of the covariant tensor approaches. In particular, we explicitly build the amplitudes for the B→ ψ π K and B→ \\bar{D}π π decays, and show that the energy dependence of the covariant approach is model dependent. We also show that the usual recursive construction of covariant tensors explicitly violates crossing symmetry, which would lead to different resonance parameters extracted from scattering and decay processes.
Exact extreme-value statistics at mixed-order transitions.
Bar, Amir; Majumdar, Satya N; Schehr, Grégory; Mukamel, David
2016-05-01
We study extreme-value statistics for spatially extended models exhibiting mixed-order phase transitions (MOT). These are phase transitions that exhibit features common to both first-order (discontinuity of the order parameter) and second-order (diverging correlation length) transitions. We consider here the truncated inverse distance squared Ising model, which is a prototypical model exhibiting MOT, and study analytically the extreme-value statistics of the domain lengths The lengths of the domains are identically distributed random variables except for the global constraint that their sum equals the total system size L. In addition, the number of such domains is also a fluctuating variable, and not fixed. In the paramagnetic phase, we show that the distribution of the largest domain length l_{max} converges, in the large L limit, to a Gumbel distribution. However, at the critical point (for a certain range of parameters) and in the ferromagnetic phase, we show that the fluctuations of l_{max} are governed by novel distributions, which we compute exactly. Our main analytical results are verified by numerical simulations.
Exact density-potential pairs from complex-shifted axisymmetric systems
NASA Astrophysics Data System (ADS)
Ciotti, Luca; Marinacci, Federico
2008-07-01
In a previous paper, the complex-shift method has been applied to self-gravitating spherical systems, producing new analytical axisymmetric density-potential pairs. We now extend the treatment to the Miyamoto-Nagai disc and the Binney logarithmic halo, and we study the resulting axisymmetric and triaxial analytical density-potential pairs; we also show how to obtain the surface density of shifted systems from the complex shift of the surface density of the parent model. In particular, the systems obtained from Miyamoto-Nagai discs can be used to describe disc galaxies with a peanut-shaped bulge or with a central triaxial bar, depending on the direction of the shift vector. By using a constructive method that can be applied to generic axisymmetric systems, we finally show that the Miyamoto-Nagai and the Satoh discs, and the Binney logarithmic halo cannot be obtained from the complex shift of any spherical parent distribution. As a by-product of this study, we also found two new generating functions in closed form for even and odd Legendre polynomials, respectively.
Salvi, Carola; Cristofori, Irene; Grafman, Jordan; Beeman, Mark
2016-01-01
Previous studies showed that liberals and conservatives differ in cognitive style. Liberals are more flexible, and tolerant of complexity and novelty, whereas conservatives are more rigid, are more resistant to change, and prefer clear answers. We administered a set of compound remote associate problems, a task extensively used to differentiate problem-solving styles (via insight or analysis). Using this task, several researches have proven that self-reports, which differentiate between insight and analytic problem-solving, are reliable and are associated with two different neural circuits. In our research we found that participants self-identifying with distinct political orientations demonstrated differences in problem-solving strategy. Liberals solved significantly more problems via insight instead of in a step-by-step analytic fashion. Our findings extend previous observations that self-identified political orientations reflect differences in cognitive styles. More specifically, we show that type of political orientation is associated with problem-solving strategy. The data converge with previous neurobehavioural and cognitive studies indicating a link between cognitive style and the psychological mechanisms that mediate political beliefs. PMID:26810954
BPS sectors of the Skyrme model and their non-BPS extensions
NASA Astrophysics Data System (ADS)
Adam, C.; Foster, D.; Krusch, S.; Wereszczynski, A.
2018-02-01
Two recently found coupled Bogomol'nyi-Prasad-Sommerfield (BPS) submodels of the Skyrme model are further analyzed. First, we provide a geometrical formulation of the submodels in terms of the eigenvalues of the strain tensor. Second, we study their thermodynamical properties and show that the mean-field equations of state coincide at high pressure and read p =ρ ¯/3 . We also provide evidence that matter described by the first BPS submodel has some similarity with a Bose-Einstein condensate. Moreover, we show that extending the second submodel to a non-BPS model by including certain additional terms of the full Skyrme model does not spoil the respective ansatz, leading to an ordinary differential equation for the profile of the Skymion, for any value of the topological charge. This allows for an almost analytical description of the properties of Skyrmions in this model. In particular, we analytically study the breaking and restoration of the BPS property. Finally, we provide an explanation of the success of the rational map ansatz.
The influence of discrete emotions on judgement and decision-making: a meta-analytic review.
Angie, Amanda D; Connelly, Shane; Waples, Ethan P; Kligyte, Vykinta
2011-12-01
During the past three decades, researchers interested in emotions and cognition have attempted to understand the relationship that affect and emotions have with cognitive outcomes such as judgement and decision-making. Recent research has revealed the importance of examining more discrete emotions, showing that same-valence emotions (e.g., anger and fear) differentially impact judgement and decision-making outcomes. Narrative reviews of the literature (Lerner & Tiedens, 2006 ; Pham, 2007 ) have identified some under-researched topics, but provide a limited synthesis of findings. The purpose of this study was to review the research examining the influence of discrete emotions on judgement and decision-making outcomes and provide an assessment of the observed effects using a meta-analytic approach. Results, overall, show that discrete emotions have moderate to large effects on judgement and decision-making outcomes. However, moderator analyses revealed differential effects for study-design characteristics and emotion-manipulation characteristics by emotion type. Implications are discussed.
NASA Technical Reports Server (NTRS)
Mixson, J. S.; Roussos, L. A.
1986-01-01
Possible reasons for disagreement between measured and predicted trends of sidewall noise transmission at low frequency are investigated using simplified analysis methods. An analytical model combining incident plane acoustic waves with an infinite flat panel is used to study the effects of sound incidence angle, plate structural properties, frequency, absorption, and the difference between noise reduction and transmission loss. Analysis shows that these factors have significant effects on noise transmission but they do not account for the differences between measured and predicted trends at low frequencies. An analytical model combining an infinite flat plate with a normally incident acoustic wave having exponentially decaying magnitude along one coordinate is used to study the effect of a localized source distribution such as is associated with propeller noise. Results show that the localization brings the predicted low-frequency trend of noise transmission into better agreement with measured propeller results. This effect is independent of low-frequency stiffness effects that have been previously reported to be associated with boundary conditions.
Salvi, Carola; Cristofori, Irene; Grafman, Jordan; Beeman, Mark
2016-01-01
Previous studies showed that liberals and conservatives differ in cognitive style. Liberals are more flexible, and tolerant of complexity and novelty, whereas conservatives are more rigid, are more resistant to change, and prefer clear answers. We administered a set of compound remote associate problems, a task extensively used to differentiate problem-solving styles (via insight or analysis). Using this task, several researches have proven that self-reports, which differentiate between insight and analytic problem-solving, are reliable and are associated with two different neural circuits. In our research we found that participants self-identifying with distinct political orientations demonstrated differences in problem-solving strategy. Liberals solved significantly more problems via insight instead of in a step-by-step analytic fashion. Our findings extend previous observations that self-identified political orientations reflect differences in cognitive styles. More specifically, we show that type of political orientation is associated with problem-solving strategy. The data converge with previous neurobehavioural and cognitive studies indicating a link between cognitive style and the psychological mechanisms that mediate political beliefs.
Analytical model for screening potential CO2 repositories
Okwen, R.T.; Stewart, M.T.; Cunningham, J.A.
2011-01-01
Assessing potential repositories for geologic sequestration of carbon dioxide using numerical models can be complicated, costly, and time-consuming, especially when faced with the challenge of selecting a repository from a multitude of potential repositories. This paper presents a set of simple analytical equations (model), based on the work of previous researchers, that could be used to evaluate the suitability of candidate repositories for subsurface sequestration of carbon dioxide. We considered the injection of carbon dioxide at a constant rate into a confined saline aquifer via a fully perforated vertical injection well. The validity of the analytical model was assessed via comparison with the TOUGH2 numerical model. The metrics used in comparing the two models include (1) spatial variations in formation pressure and (2) vertically integrated brine saturation profile. The analytical model and TOUGH2 show excellent agreement in their results when similar input conditions and assumptions are applied in both. The analytical model neglects capillary pressure and the pressure dependence of fluid properties. However, simulations in TOUGH2 indicate that little error is introduced by these simplifications. Sensitivity studies indicate that the agreement between the analytical model and TOUGH2 depends strongly on (1) the residual brine saturation, (2) the difference in density between carbon dioxide and resident brine (buoyancy), and (3) the relationship between relative permeability and brine saturation. The results achieved suggest that the analytical model is valid when the relationship between relative permeability and brine saturation is linear or quasi-linear and when the irreducible saturation of brine is zero or very small. ?? 2011 Springer Science+Business Media B.V.
Parametrization of local CR automorphisms by finite jets and applications
NASA Astrophysics Data System (ADS)
Lamel, Bernhard; Mir, Nordine
2007-04-01
For any real-analytic hypersurface Msubset {C}^N , which does not contain any complex-analytic subvariety of positive dimension, we show that for every point pin M the local real-analytic CR automorphisms of M fixing p can be parametrized real-analytically by their ell_p jets at p . As a direct application, we derive a Lie group structure for the topological group operatorname{Aut}(M,p) . Furthermore, we also show that the order ell_p of the jet space in which the group operatorname{Aut}(M,p) embeds can be chosen to depend upper-semicontinuously on p . As a first consequence, it follows that given any compact real-analytic hypersurface M in {C}^N , there exists an integer k depending only on M such that for every point pin M germs at p of CR diffeomorphisms mapping M into another real-analytic hypersurface in {C}^N are uniquely determined by their k -jet at that point. Another consequence is the following boundary version of H. Cartan's uniqueness theorem: given any bounded domain Ω with smooth real-analytic boundary, there exists an integer k depending only on partial Ω such that if H\\colon Ωto Ω is a proper holomorphic mapping extending smoothly up to partial Ω near some point pin partial Ω with the same k -jet at p with that of the identity mapping, then necessarily H=Id . Our parametrization theorem also holds for the stability group of any essentially finite minimal real-analytic CR manifold of arbitrary codimension. One of the new main tools developed in the paper, which may be of independent interest, is a parametrization theorem for invertible solutions of a certain kind of singular analytic equations, which roughly speaking consists of inverting certain families of parametrized maps with singularities.
Kim, Manuela Leticia; Tudino, Mabel Beatríz
2010-08-15
Several studies involving the physicochemical interaction of three silica based hybrid mesoporous materials with metal ions of the group IB have been performed in order to employ them for preconcentration purposes in the determination of traces of Cu(II), Ag(I) and Au(III). The three solids were obtained from mesoporous silica functionalized with 3-aminopropyl (APS), 3-mercaptopropyl (MPS) and N-[2-aminoethyl]-3-aminopropyl (NN) groups, respectively. Adsorption capacities for Au, Cu and Ag were calculated using Langmuir's isotherm model and then, the optimal values for the retention of each element onto each one of the solids were found. Physicochemical data obtained under thermodynamic equilibrium and under kinetic conditions - imposed by flow through experiments - allowed the design of simple analytical methodologies where the solids were employed as fillings of microcolumns held in continuous systems coupled on-line to an atomic absorption spectrometry. In order to control the interaction between the filling and the analyte at short times (flow through conditions) and thus, its effect on the analytical signal and the presence of interferences, the initial adsorption velocities were calculated using the pseudo second order model. All these experiments allowed the comparison of the solids in terms of their analytical behaviour at the moment of facing the determination of the three elements. Under optimized conditions mainly given by the features of the filling, the analytical methodologies developed in this work showed excellent performances with limits of detection of 0.14, 0.02 and 0.025 microg L(-1) and RSD % values of 3.4, 2.7 and 3.1 for Au, Cu and Ag, respectively. A full discussion of the main findings on the interaction metal ions/fillings will be provided. The analytical results for the determination of the three metals will be also presented. Copyright 2010 Elsevier B.V. All rights reserved.
Bassuoni, M.M.
2013-01-01
The dehumidifier is a key component in liquid desiccant air-conditioning systems. Analytical solutions have more advantages than numerical solutions in studying the dehumidifier performance parameters. This paper presents the performance results of exit parameters from an analytical model of an adiabatic cross-flow liquid desiccant air dehumidifier. Calcium chloride is used as desiccant material in this investigation. A program performing the analytical solution is developed using the engineering equation solver software. Good accuracy has been found between analytical solution and reliable experimental results with a maximum deviation of +6.63% and −5.65% in the moisture removal rate. The method developed here can be used in the quick prediction of the dehumidifier performance. The exit parameters from the dehumidifier are evaluated under the effects of variables such as air temperature and humidity, desiccant temperature and concentration, and air to desiccant flow rates. The results show that hot humid air and desiccant concentration have the greatest impact on the performance of the dehumidifier. The moisture removal rate is decreased with increasing both air inlet temperature and desiccant temperature while increases with increasing air to solution mass ratio, inlet desiccant concentration, and inlet air humidity ratio. PMID:25685485
The Lasting Effect of Civic Talk on Civic Participation: Evidence from a Panel Study
ERIC Educational Resources Information Center
Klofstad, Casey A.
2010-01-01
Extant research shows that individuals who discuss politics and current events with their peers also participate more actively in civil society. However, this correlation is not sufficient evidence of causation due to a number of analytical biases. To address this problem, data were collected through a panel study conducted on students who were…
Analytical formulation of cellular automata rules using data models
NASA Astrophysics Data System (ADS)
Jaenisch, Holger M.; Handley, James W.
2009-05-01
We present a unique method for converting traditional cellular automata (CA) rules into analytical function form. CA rules have been successfully used for morphological image processing and volumetric shape recognition and classification. Further, the use of CA rules as analog models to the physical and biological sciences can be significantly extended if analytical (as opposed to discrete) models could be formulated. We show that such transformations are possible. We use as our example John Horton Conway's famous "Game of Life" rule set. We show that using Data Modeling, we are able to derive both polynomial and bi-spectrum models of the IF-THEN rules that yield equivalent results. Further, we demonstrate that the "Game of Life" rule set can be modeled using the multi-fluxion, yielding a closed form nth order derivative and integral. All of the demonstrated analytical forms of the CA rule are general and applicable to real-time use.
Improving laboratory results turnaround time by reducing pre analytical phase.
Khalifa, Mohamed; Khalid, Parwaiz
2014-01-01
Laboratory turnaround time is considered one of the most important indicators of work efficiency in hospitals, physicians always need timely results to take effective clinical decisions especially in the emergency department where these results can guide physicians whether to admit patients to the hospital, discharge them home or do further investigations. A retrospective data analysis study was performed to identify the effects of ER and Lab staff training on new routines for sample collection and transportation on the pre-analytical phase of turnaround time. Renal profile tests requested by the ER and performed in 2013 has been selected as a sample, and data about 7,519 tests were retrieved and analyzed to compare turnaround time intervals before and after implementing new routines. Results showed significant time reduction on "Request to Sample Collection" and "Collection to In Lab Delivery" time intervals with less significant improvement on the analytical phase of the turnaround time.
An experimental and analytical investigation of isolated rotor flap-lag stability in forward flight
NASA Technical Reports Server (NTRS)
Gaonkar, Gopal H.; Mcnulty, Michael J.
1985-01-01
For flap-lag stability of isolated rotors, experimental and analytical investigations are conducted in hover and forward flight on the adequacy of a linear quasi-steady aerodynamics theory with dynamic inflow. Forward flight effects on lag regressing mode are emphasized. Accordingly, a soft inplane hingeless rotor with three blades is tested at advance ratios as high as 0.55 and at shaft angles as high as 20 deg. The 1.62-m model rotor is untrimmed with an essentially unrestricted tilt of the tip path plane. By computerized symbolic manipulation, an analytical model is developed in substall to predict stability margins with mode indentification. It also predicts substall and stall regions to help explain the correlation between theory and data. The correlation shows both the strengths and weaknesses of the data and theory, and promotes further insights into areas in which further study is needed in substall and stall.
Parametric Modeling of the Safety Effects of NextGen Terminal Maneuvering Area Conflict Scenarios
NASA Technical Reports Server (NTRS)
Rogers, William H.; Waldron, Timothy P.; Stroiney, Steven R.
2011-01-01
The goal of this work was to analytically identify and quantify the issues, challenges, technical hurdles, and pilot-vehicle interface issues associated with conflict detection and resolution (CD&R)in emerging operational concepts for a NextGen terminal aneuvering area, including surface operations. To this end, the work entailed analytical and trade studies focused on modeling the achievable safety benefits of different CD&R strategies and concepts in the current and future airport environment. In addition, crew-vehicle interface and pilot performance enhancements and potential issues were analyzed based on review of envisioned NextGen operations, expected equipage advances, and human factors expertise. The results of perturbation analysis, which quantify the high-level performance impact of changes to key parameters such as median response time and surveillance position error, show that the analytical model developed could be useful in making technology investment decisions.
Potvin, Christopher M; Zhou, Hongde
2011-11-01
The objective of this study was to demonstrate the effects of complex matrix effects caused by chemical materials on the analysis of key soluble microbial products (SMP) including proteins, humics, carbohydrates, and polysaccharides in activated sludge samples. Emphasis was placed on comparison of the commonly used standard curve technique with standard addition (SA), a technique that differs in that the analytical responses are measured for sample solutions spiked with known quantities of analytes. The results showed that using SA provided a great improvement in compensating for SMP recovery and thus improving measurement accuracy by correcting for matrix effects. Analyte recovery was found to be highly dependent on sample dilution, and changed due to extraction techniques, storage conditions and sample composition. Storage of sample extracts by freezing changed SMP concentrations dramatically, as did storage at 4°C for as little as 1d. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Serna Moreno, M. C.; Romero Gutierrez, A.; Martínez Vicente, J. L.
2016-07-01
An analytical model has been derived for describing the results of three-point-bending tests in materials with different behaviour under tension and compression. The shift of the neutral plane and the damage initiation mode and its location have been defined. The validity of the equations has been reviewed by testing carbon fibre-reinforced polymers (CFRP), typically employed in different weight-critical applications. Both unidirectional and cross-ply laminates have been studied. The initial failure mode produced depends directly on the beam span- thickness relation. Therefore, specimens with different thicknesses have been analysed for examining the damage initiation due to either the bending moment or the out-of-plane shear load. The experimental description of the damage initiation and evolution has been shown by means of optical microscopy. The good agreement between the analytical estimations and the experimental results shows the validity of the analytical model exposed.
NASA Astrophysics Data System (ADS)
Yu, Ming-Xiao; Tian, Bo; Chai, Jun; Yin, Hui-Min; Du, Zhong
2017-10-01
In this paper, we investigate a nonlinear fiber described by a (2+1)-dimensional complex Ginzburg-Landau equation with the chromatic dispersion, optical filtering, nonlinear and linear gain. Bäcklund transformation in the bilinear form is constructed. With the modified bilinear method, analytic soliton solutions are obtained. For the soliton, the amplitude can decrease or increase when the absolute value of the nonlinear or linear gain is enlarged, and the width can be compressed or amplified when the absolute value of the chromatic dispersion or optical filtering is enhanced. We study the stability of the numerical solutions numerically by applying the increasing amplitude, embedding the white noise and adding the Gaussian pulse to the initial values based on the analytic solutions, which shows that the numerical solutions are stable, not influenced by the finite initial perturbations.
NASA Astrophysics Data System (ADS)
Vvedenskii, N. V.; Kostin, V. A.; Laryushin, I. D.; Silaev, A. A.
2016-05-01
We have studied the processes of excitation of low-frequency residual currents in a plasma produced through ionisation of gases by two-colour laser pulses in laser-plasma schemes for THz generation. We have developed an analytical approach that allows one to find residual currents in the case when one of the components of a two-colour pulse is weak enough. The derived analytical expressions show that the effective generation of the residual current (and hence the effective THz generation) is possible if the ratio of the frequencies in the two-colour laser pulse is close to a rational fraction with a not very big odd sum of the numerator and denominator. The results of numerical calculations (including those based on the solution of the three-dimensional time-dependent Schrödinger equation) agree well with the analytical results.
Implications on 1+1 D runup modeling due to time features of the earthquake source
NASA Astrophysics Data System (ADS)
Fuentes, M.; Riquelme, S.; Campos, J. A.
2017-12-01
The time characteristics of the seismic source are usually neglected in tsunami modeling, due to the difference in the time scale of both processes. Nonetheless, there are just a few analytical studies that intended to explain separately the role of the rise time and the rupture velocity. In this work, we extend an analytical 1+1D solution for the shoreline motion time series, from the static case to the dynamic case, by including both, rise time and rupture velocity. Results show that the static case correspond to a limit case of null rise time and infinite rupture velocity. Both parameters contribute in shifting the arrival time, but maximum run-up may be affected by very slow ruptures and long rise time. The analytical solution has been tested for the Nicaraguan tsunami earthquake, suggesting that the rupture was not slow enough to cause wave amplification to explain the high runup observations.
Fe 2O 3-Au hybrid nanoparticles for sensing applications via SERS analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Searles, Emily; Murph, Simona Hunyadi
Multifunctional iron oxide-gold hybrid nanostructures have been produced via solution chemistries and investigated for analyte detection. Gold nanoparticles of various shapes have been used for probing surface-enhanced Raman scattering (SERS) effects as they display unique optical properties in the visible-near IR region of the spectrum. When coupled with other nanoparticles, namely iron oxide nanoparticles, hybrid structures with increased functionality were produced. By exploiting their magnetic properties, nanogaps or “hot spots” were rationally created and evaluated for SERS enhancement studies. The “hot spots” were created by using a seeded reaction to increase the gold loading on the iron oxide support bymore » 43% by weight. SERS Nanomaterials were evaluated for their ability to promote surface-enhanced Raman scattering of a model analyte, 4-mercaptophenol. The data shows an enhancement effect of the model analyte on gold decorated iron oxide nanoparticles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yanguas-Gil, Angel; Elam, Jeffrey W.
2014-05-01
In this work, the authors present analytic models for atomic layer deposition (ALD) in three common experimental configurations: cross-flow, particle coating, and spatial ALD. These models, based on the plug-flow and well-mixed approximations, allow us to determine the minimum dose times and materials utilization for all three configurations. A comparison between the three models shows that throughput and precursor utilization can each be expressed by universal equations, in which the particularity of the experimental system is contained in a single parameter related to the residence time of the precursor in the reactor. For the case of cross-flow reactors, the authorsmore » show how simple analytic expressions for the reactor saturation profiles agree well with experimental results. Consequently, the analytic model can be used to extract information about the ALD surface chemistry (e. g., the reaction probability) by comparing the analytic and experimental saturation profiles, providing a useful tool for characterizing new and existing ALD processes. (C) 2014 American Vacuum Society« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, Scott D.; Eckberg, Alison D.; Thallapally, Praveen K.
2011-09-01
The metal-organic framework Cu-BTC was evaluated for its ability to selectively interact with Lewis-base analytes, including explosives, by examining retention on GC columns packed with Chromosorb W HP that contained 3.0% SE-30 along with various loadings of Cu-BTC. SEM images of the support material showed the characteristic Cu-BTC crystals embedded in the SE-30 coating on the diatomaceous support. Results indicated that the Cu-BTC-containing stationary phase had limited thermal stability (220°C) and strong general retention for analytes. Kováts index calculations showed selective retention (amounting to about 300 Kováts units) relative to n-alkanes for many small Lewis-base analytes on a column thatmore » contained 0.75% Cu-BTC compared to an SE-30 control. Short columns that contained lower loadings of Cu-BTC (0.10%) were necessary to elute explosives and related analytes; however, selectivity was not observed for aromatic compounds (including nitroaromatics) or nitroalkanes. Observed retention characteristics are discussed.« less
On the Occurrence of Liquation During Linear Friction Welding of Ni-Based Superalloys
NASA Astrophysics Data System (ADS)
Masoumi, F.; Shahriari, D.; Jahazi, M.; Cormier, J.; Flipo, B. C. D.
2017-06-01
A combination of experimental and analytical methods was used to study the possible occurrence of liquation during LFW of the newly developed AD730TM Ni-based superalloy. LFWed joints were produced using a semi-industrial size facility and the interfaces of the joints as well as the ejected flash were examined using optical and Field Emission Gun Scanning Electron Microscopy (FEG-SEM). Physical simulation of the LFW thermal cycle, using thermomechanical simulator Gleeble™ 3800, showed that incipient melting started from 1473 K (1200 °C). The analytical model, calibrated by experiments, predicted that the highest temperature of the interface was about 1523 K (1250 °C). The constitutive equations based on lattice and pipe diffusion models were developed to quantify the self-diffusivity of the elements and control the extent of liquation by considering the effect of LFW process parameters. Analytical results show that the application of compressive stresses during LFW results in 25 times increase in the diffusion of Ni atoms at the weld interface. Therefore, no presence of re-solidified phases, i.e., occurrence of liquation, was observed in the microstructure of the weld zone or the flash in the present study. Based on the obtained results, a methodology was developed for designing the optimum pressure above which no liquation, and hence cracking, will be observable.
Bio-analytical applications of mid-infrared spectroscopy using silver halide fiber-optic probes1
NASA Astrophysics Data System (ADS)
Heise, H. M.; Küpper, L.; Butvina, L. N.
2002-10-01
Infrared-spectroscopy has proved to be a powerful method for the study of various biomedical samples, in particular for in-vitro analysis in the clinical laboratory and for non-invasive diagnostics. In general, the analysis of biofluids such as whole blood, urine, microdialysates and bioreactor broth media takes advantage of the fact that a multitude of analytes can be quantified simultaneously and rapidly without the need for reagents. Progress in the quality of infrared silver halide fibers enabled us to construct several flexible fiber-optic probes of different geometries, which are particularly suitable for the measurement of small biosamples. Recent trends show that dry film measurements by mid-infrared spectroscopy could revolutionize analytical tools in the clinical chemistry laboratory, and an example is given. Infrared diagnostic tools show a promising potential for patients, and minimal-invasive blood glucose assays or skin tissue pathology in particular cannot be left out using mid-infrared fiber-based probes. Other applications include the measurement of skin samples including penetration studies of vitamins and constituents of cosmetic cream formulations. A further field is the micro-domain analysis of biopsy samples from bog mummified corpses, and recent results on the chemistry of dermis and hair samples are reported. Another field of application, for which results are reported, is food analysis and bio-reactor monitoring.
Evolutionary Games of Multiplayer Cooperation on Graphs
Arranz, Jordi; Traulsen, Arne
2016-01-01
There has been much interest in studying evolutionary games in structured populations, often modeled as graphs. However, most analytical results so far have only been obtained for two-player or linear games, while the study of more complex multiplayer games has been usually tackled by computer simulations. Here we investigate evolutionary multiplayer games on graphs updated with a Moran death-Birth process. For cycles, we obtain an exact analytical condition for cooperation to be favored by natural selection, given in terms of the payoffs of the game and a set of structure coefficients. For regular graphs of degree three and larger, we estimate this condition using a combination of pair approximation and diffusion approximation. For a large class of cooperation games, our approximations suggest that graph-structured populations are stronger promoters of cooperation than populations lacking spatial structure. Computer simulations validate our analytical approximations for random regular graphs and cycles, but show systematic differences for graphs with many loops such as lattices. In particular, our simulation results show that these kinds of graphs can even lead to more stringent conditions for the evolution of cooperation than well-mixed populations. Overall, we provide evidence suggesting that the complexity arising from many-player interactions and spatial structure can be captured by pair approximation in the case of random graphs, but that it need to be handled with care for graphs with high clustering. PMID:27513946
Shah, Anjana K.; Bedrosian, Paul A.; Anderson, Eric D.; Kelley, Karen D.; Lang, James
2013-01-01
We combined aeromagnetic, induced polarization, magnetotelluric, and gravity surveys as well as drillhole geologic, alteration, magnetic susceptibility, and density data for exploration and characterization of the Cu-Au-Mo Pebble porphyry deposit. This undeveloped deposit is almost completely concealed by postmineralization sedimentary and volcanic rocks, presenting an exploration challenge. Individual geophysical methods primarily assist regional characterization. Positive chargeability and conductivity anomalies are observed over a broad region surrounding the deposit, likely representing sulfide minerals that accumulated during multiple stages of hydrothermal alteration. The mineralized area occupies only a small part of the chargeability anomaly because sulfide precipitation was not unique to the deposit, and mafic rocks also exhibit strong chargeability. Conductivity anomalies similarly reflect widespread sulfides as well as water-saturated glacial sediments. Mineralogical and magnetic susceptibility data indicate magnetite destruction primarily within the Cu-Au-Mo mineralized area. The magnetic field does not show a corresponding anomaly low but the analytic signal does in areas where the deposit is not covered by postmineralization igneous rocks. The analytic signal shows similar lows over sedimentary rocks outside of the mineralized area, however, and cannot uniquely distinguish the deposit. We find that the intersection of positive chargeability anomalies with analytic signal lows, indicating elevated sulfide concentrations but low magnetite at shallow depths, roughly delineates the deposit where it is covered only by glacial sediments. Neither chargeability highs nor analytic signal lows are present where the deposit is covered by several hundred meters of sedimentary and volcanic rocks, but a 3D resistivity model derived from magnetotelluric data shows a corresponding zone of higher conductivity. Gravity data highlight geologic features within the deposit, including shallow diorite sills that locally contain higher-grade mineralization. The results thus show ways in which an integrated survey approach might be used to distinguish zones of potentially economic mineralization.
Synthesis and Characterization of Hydroxyapatite Powder by Wet Precipitation Method
NASA Astrophysics Data System (ADS)
Cahyaningrum, S. E.; Herdyastuty, N.; Devina, B.; Supangat, D.
2018-01-01
Hydroxyapatite is main inorganic component of the bone with formula Ca10(PO4)6(OH)2. Hydroxyapatite can be used as substituted bone biomaterial because biocompatible, non toxic, and osteoconductive. In this study, hydroxyapatite is synthesized using wet precipitation method from egg shell. The product was sintered at different temperatures of 800°C to 1000°C to improve its crystallinity. The hydroxyapatite was characterized by X-ray analysis, Scanning Electron Microscopy (SEM) and Fourier Transform Infrared Spectroscopy (FTIR) to reveal its phase content, morphology and types of bond present within it. The analytical results showed hydroxyapatite had range in crystallinity from 85.527 to 98.753%. The analytical functional groups showed that presence of functional groups such as OH, (PO4)3 2-, and CO3 2- that indicated as hydroxyapatite. The result of characterization SEM indicated that hydroxyapatite without sintering and HAp sintering at 800 °C were irregular shape without pore. The best hydroxyapatite with temperature sintering at 900 °C showed oval shaped with pores without agglomerated.
Asadpour-Zeynali, Karim; Saeb, Elhameh
2016-01-01
Three antituberculosis medications are investigated in this work consist of rifampicin, isoniazid and pyrazinamide. The ultra violet (UV) spectra of these compounds are overlapped, thus use of suitable chemometric methods are helpful for simultaneous spectrophotometric determination of them. A generalized version of net analyte signal standard addition method (GNASSAM) was used for determination of three antituberculosis medications as a model system. In generalized net analyte signal standard addition method only one standard solution was prepared for all analytes. This standard solution contains a mixture of all analytes of interest, and the addition of such solution to sample, causes increases in net analyte signal of each analyte which are proportional to the concentrations of analytes in added standards solution. For determination of concentration of each analyte in some synthetic mixtures, the UV spectra of pure analytes and each sample were recorded in the range of 210 nm-550 nm. The standard addition procedure was performed for each sample and the UV spectrum was recorded after each addition and finally the results were analyzed by net analyte signal method. Obtained concentrations show acceptable performance of GNASSAM in these cases. PMID:28243267
Yearly trend of dicarboxylic acids in organic aerosols from south of Sweden and source attribution
NASA Astrophysics Data System (ADS)
Hyder, Murtaza; Genberg, Johan; Sandahl, Margareta; Swietlicki, Erik; Jönsson, Jan Åke
2012-09-01
Seven aliphatic dicarboxylic acids (C3-C9) along with phthalic acid, pinic acid and pinonic acid were determined in 35 aerosol (PM10) samples collected over the year at Vavihill sampling station in south of Sweden. Mixture of dichloromethane and methanol (ratio 1:3) was preferred over water for extraction of samples and extraction was assisted by ultrasonic agitation. Analytes were derivatized using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) containing 1% trimethylsilyl chloride and analyzed using gas chromatography/mass spectrometry. Among studied analytes, azelaic acid was found maximum with an average concentration of 6.0 ± 3.6 ng m-3 and minimum concentration was found for pimelic acid (1.06 ± 0.63 ng m-3). A correlation coefficients analysis was used for defining the possible sources of analytes. Higher dicarboxylic acids (C7-C9) showed a strong correlation with each other (correlation coefficients (r) range, 0.96-0.97). Pinic and pinonic acids showed an increase in concentration during summer. Lower carbon number dicarboxylic acids (C3-C6) and phthalic acid were found strongly correlated, but showed a poor correlation with higher carbon number dicarboxylic acids (C7-C9), suggesting a different source for them. Biomass burning, vehicle exhaust, photo-oxidation of volatile organic compounds (natural and anthropogenic emissions) were possible sources for dicarboxylic acids.
The role of decision analytic modeling in the health economic assessment of spinal intervention.
Edwards, Natalie C; Skelly, Andrea C; Ziewacz, John E; Cahill, Kevin; McGirt, Matthew J
2014-10-15
Narrative review. To review the common tenets, strengths, and weaknesses of decision modeling for health economic assessment and to review the use of decision modeling in the spine literature to date. For the majority of spinal interventions, well-designed prospective, randomized, pragmatic cost-effectiveness studies that address the specific decision-in-need are lacking. Decision analytic modeling allows for the estimation of cost-effectiveness based on data available to date. Given the rising demands for proven value in spine care, the use of decision analytic modeling is rapidly increasing by clinicians and policy makers. This narrative review discusses the general components of decision analytic models, how decision analytic models are populated and the trade-offs entailed, makes recommendations for how users of spine intervention decision models might go about appraising the models, and presents an overview of published spine economic models. A proper, integrated, clinical, and economic critical appraisal is necessary in the evaluation of the strength of evidence provided by a modeling evaluation. As is the case with clinical research, all options for collecting health economic or value data are not without their limitations and flaws. There is substantial heterogeneity across the 20 spine intervention health economic modeling studies summarized with respect to study design, models used, reporting, and general quality. There is sparse evidence for populating spine intervention models. Results mostly showed that interventions were cost-effective based on $100,000/quality-adjusted life-year threshold. Spine care providers, as partners with their health economic colleagues, have unique clinical expertise and perspectives that are critical to interpret the strengths and weaknesses of health economic models. Health economic models must be critically appraised for both clinical validity and economic quality before altering health care policy, payment strategies, or patient care decisions. 4.
Development of an aptamer beacon for detection of interferon-gamma.
Tuleuova, Nazgul; Jones, Caroline N; Yan, Jun; Ramanculov, Erlan; Yokobayashi, Yohei; Revzin, Alexander
2010-03-01
Traditional antibody-based affinity sensing strategies employ multiple reagents and washing steps and are unsuitable for real-time detection of analyte binding. Aptamers, on the other hand, may be designed to monitor binding events directly, in real-time, without the need for secondary labels. The goal of the present study was to design an aptamer beacon for fluorescence resonance energy transfer (FRET)-based detection of interferon-gamma (IFN-gamma)--an important inflammatory cytokine. Variants of DNA aptamer modified with biotin moieties and spacers were immobilized on avidin-coated surfaces and characterized by surface plasmon resonance (SPR). The SPR studies showed that immobilization of aptamer via the 3' end resulted in the best binding IFN-gamma (K(d) = 3.44 nM). This optimal aptamer variant was then used to construct a beacon by hybridizing fluorophore-labeled aptamer with an antisense oligonucleotide strand carrying a quencher. SPR studies revealed that IFN-gamma binding with an aptamer beacon occurred within 15 min of analyte introduction--suggesting dynamic replacement of the quencher-complementary strand by IFN-gamma molecules. To further highlight biosensing applications, aptamer beacon molecules were immobilized inside microfluidic channels and challenged with varying concentration of analyte. Fluorescence microscopy revealed low fluorescence in the absence of analyte and high fluorescence after introduction of IFN-gamma. Importantly, unlike traditional antibody-based immunoassays, the signal was observed directly upon binding of analyte without the need for multiple washing steps. The surface immobilized aptamer beacon had a linear range from 5 to 100 nM and a lower limit of detection of 5 nM IFN-gamma. In conclusion, we designed a FRET-based aptamer beacon for monitoring of an inflammatory cytokine-IFN-gamma. In the future, this biosensing strategy will be employed to monitor dynamics of cytokine production by the immune cells.
Analytic representation of FK/Fπ in two loop chiral perturbation theory
NASA Astrophysics Data System (ADS)
Ananthanarayan, B.; Bijnens, Johan; Friot, Samuel; Ghosh, Shayan
2018-05-01
We present an analytic representation of FK/Fπ as calculated in three-flavor two-loop chiral perturbation theory, which involves expressing three mass scale sunsets in terms of Kampé de Fériet series. We demonstrate how approximations may be made to obtain relatively compact analytic representations. An illustrative set of fits using lattice data is also presented, which shows good agreement with existing fits.
Generalized M-factor of hollow Gaussian beams through a hard-edge circular aperture
NASA Astrophysics Data System (ADS)
Deng, Dongmei
2005-06-01
Based on the generalized truncated second-order moments, the generalized M-factor (MG2-factor) of three-dimensional hollow Gaussian beams (HGBs) through a hard-edge circular aperture is studied in cylindrical coordinate system analytically and numerically. The closed-form expression for the MG2-factor of the truncated HGBs, which is dependent on the truncation parameter β and the beam order n, can be simplified to that of the truncated, the untruncated Gaussian beams and the untruncated HGBs. Also, the power fraction is demonstrated analytically and numerically, which shows that the area of the dark region across the HGBs increases as n increasing.
NASA Technical Reports Server (NTRS)
Amos, D. J.
1977-01-01
An analytical evaluation was conducted to determine quantitatively the improvement potential in cycle efficiency and cost of electricity made possible by the introduction of thermal barrier coatings to power generation combustion turbine systems. The thermal barrier system, a metallic bond coat and yttria stabilized zirconia outer layer applied by plasma spray techniques, acts as a heat insulator to provide substantial metal temperature reductions below that of the exposed thermal barrier surface. The study results show the thermal barrier to be a potentially attractive means for improving performance and reducing cost of electricity for the simple, recuperated, and combined cycles evaluated.
Quantification of astaxanthin in shrimp waste hydrolysate by HPLC.
López-Cervantes, J; Sánchez-Machado, D I; Gutiérrez-Coronado, M A; Ríos-Vázquez, N J
2006-10-01
In the present study, a simple and rapid reversed-phase HPLC method for the determination of astaxanthin in shrimp waste hydrolysate has been developed and validated. The analytical procedure involves the direct extraction of astaxanthin from the lipid fraction with methanol. The analytical column, SS Exil ODS, was operated at 25C. The mobile phase consisted of a mixture of water:methanol:dichloromethane:acetonitrile (4.5:28:22:45.5 v/v/v/v) at a flow rate of 1.0 mL/min. Detection and identification were performed using a photodiode array detector (lambda(detection) = 476 nm). The proposed HPLC method showed adequate linearity, repeatability and accuracy.
NASA Astrophysics Data System (ADS)
Govindarajan, A.; Vijayalakshmi, R.; Ramamurthy, V.
2018-04-01
The main aim of this article is to study the combined effects of heat and mass transfer to radiative Magneto Hydro Dynamics (MHD) oscillatory optically thin dusty fluid in a saturated porous medium channel. Based on certain assumptions, the momentum, energy, concentration equations are obtained.The governing equations are non-dimensionalised, simplified and solved analytically. The closed analytical form solutions for velocity, temperature, concentration profiles are obtained. Numerical computations are presented graphically to show the salient features of various physical parameters. The shear stress, the rate of heat transfer and the rate of mass transfer are also presented graphically.
Analytical Solutions to Backreaction on Cosmic Strings
NASA Astrophysics Data System (ADS)
Wachter, Jeremy M.
2017-08-01
We present analytical studies of gravitational and electromagnetic backreaction on cosmic strings. For oscillating loops of cosmic string, we present a general argument for how kinks must change; additionally, we apply this general argument to the geometrically simple case of the Garfinkle-Vachaspati loop. Our results suggest that the formation of cusps on loops is delayed, and so we should expect fewer cuspy signatures to be seen in gravitational wave observations. Electromagnetic backreaction we show to reduce currents on a string at least as rapidly as necessary to avoid a paradox, and currents induced on a superconducting straight string will be asymptotically reduced to zero.
Finley, Anna J; Tang, David; Schmeichel, Brandon J
2015-01-01
Prior research has found that persons who favor more analytic modes of thought are less religious. We propose that individual differences in analytic thought are associated with reduced religious beliefs particularly when analytic thought is measured (hence, primed) first. The current study provides a direct replication of prior evidence that individual differences in analytic thinking are negatively related to religious beliefs when analytic thought is measured before religious beliefs. When religious belief is measured before analytic thinking, however, the negative relationship is reduced to non-significance, suggesting that the link between analytic thought and religious belief is more tenuous than previously reported. The current study suggests that whereas inducing analytic processing may reduce religious belief, more analytic thinkers are not necessarily less religious. The potential for measurement order to inflate the inverse correlation between analytic thinking and religious beliefs deserves additional consideration.
Finley, Anna J.; Tang, David; Schmeichel, Brandon J.
2015-01-01
Prior research has found that persons who favor more analytic modes of thought are less religious. We propose that individual differences in analytic thought are associated with reduced religious beliefs particularly when analytic thought is measured (hence, primed) first. The current study provides a direct replication of prior evidence that individual differences in analytic thinking are negatively related to religious beliefs when analytic thought is measured before religious beliefs. When religious belief is measured before analytic thinking, however, the negative relationship is reduced to non-significance, suggesting that the link between analytic thought and religious belief is more tenuous than previously reported. The current study suggests that whereas inducing analytic processing may reduce religious belief, more analytic thinkers are not necessarily less religious. The potential for measurement order to inflate the inverse correlation between analytic thinking and religious beliefs deserves additional consideration. PMID:26402334
Park, Yu Jin; Rim, John Hoon; Yim, Jisook; Lee, Sang-Guk; Kim, Jeong-Ho
2017-08-01
The use of iodinated contrast media has grown in popularity in the past two decades, but relatively little attention has been paid to the possible interferential effects of contrast media on laboratory test results. Herein, we investigate medical contrast media interference with routine chemistry results obtained by three automated chemistry analyzers. Ten levels of pooled serum were used in the study. Two types of medical contrast media [Iopamiro (iopamidol) and Omnipaque (iohexol)] were evaluated. To evaluate the dose-dependent effects of the contrast media, iopamidol and iohexol were spiked separately into aliquots of serum for final concentrations of 1.8%, 3.6%, 5.5%, 7.3%, and 9.1%. The 28 analytes included in the routine chemistry panel were measured by using Hitachi 7600, AU5800, and Cobas c702 analyzers. We calculated the delta percentage difference (DPD) between the samples and the control, and examined dose-dependent trends. When the mean DPD values were compared with the reference cut-off criteria, the only uniformly interferential effect observed for all analyzers was in total protein with iopamidol. Two additional analytes that showed trends toward interferential effects only in few analyzers and exceeded the limits of the allowable error were the serum iron and the total CO 2 . The other combinations of analyzer and contrast showed no consistent dose-dependent propensity for change in any analyte level. Our study suggests that many of the analytes included in routine chemistry results, except total protein and serum iron, are not significantly affected by iopamidol and iohexol. These results suggest that it would be beneficial to apply a flexible medical evaluation process for patients requiring both laboratory tests and imaging studies, minimizing the need for strict regulations for sequential tests. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Rao, Shalinee; Masilamani, Suresh; Sundaram, Sandhya; Duvuru, Prathiba; Swaminathan, Rajendiran
2016-01-01
Quality monitoring in histopathology unit is categorized into three phases, pre-analytical, analytical and post-analytical, to cover various steps in the entire test cycle. Review of literature on quality evaluation studies pertaining to histopathology revealed that earlier reports were mainly focused on analytical aspects with limited studies on assessment of pre-analytical phase. Pre-analytical phase encompasses several processing steps and handling of specimen/sample by multiple individuals, thus allowing enough scope for errors. Due to its critical nature and limited studies in the past to assess quality in pre-analytical phase, it deserves more attention. This study was undertaken to analyse and assess the quality parameters in pre-analytical phase in a histopathology laboratory. This was a retrospective study done on pre-analytical parameters in histopathology laboratory of a tertiary care centre on 18,626 tissue specimens received in 34 months. Registers and records were checked for efficiency and errors for pre-analytical quality variables: specimen identification, specimen in appropriate fixatives, lost specimens, daily internal quality control performance on staining, performance in inter-laboratory quality assessment program {External quality assurance program (EQAS)} and evaluation of internal non-conformities (NC) for other errors. The study revealed incorrect specimen labelling in 0.04%, 0.01% and 0.01% in 2007, 2008 and 2009 respectively. About 0.04%, 0.07% and 0.18% specimens were not sent in fixatives in 2007, 2008 and 2009 respectively. There was no incidence of specimen lost. A total of 113 non-conformities were identified out of which 92.9% belonged to the pre-analytical phase. The predominant NC (any deviation from normal standard which may generate an error and result in compromising with quality standards) identified was wrong labelling of slides. Performance in EQAS for pre-analytical phase was satisfactory in 6 of 9 cycles. A low incidence of errors in pre-analytical phase implies that a satisfactory level of quality standards was being practiced with still scope for improvement.
Complete phase diagram of DNA unzipping: eye, Y fork, and triple point.
Kapri, Rajeev; Bhattacharjee, Somendra M; Seno, Flavio
2004-12-10
We study the unzipping of double stranded DNA by applying a pulling force at a fraction s (0< or =s < or =1) from the anchored end. From exact analytical and numerical results, the complete phase diagram is presented. The phase diagram shows a strong ensemble dependence for various values of s. In addition, we show the existence of an eye phase and a triple point.
Valero-Aguayo, Luis; Ferro-García, Rafael; López-Bermúdez, Miguel Ángel; Selva-López de Huralde, María de los Ángeles
2014-01-01
The Experiencing of Self Scale (EOSS) was created to evaluate the experience of the personal self, within the field of Functional Analytic Psychotherapy. This paper presents a study of the reliability and validity of the EOSS in a Spanish sample. The study sample, chosen from 24 different centres, comprised 1,040 participants aged between 18-75, of whom 32% were men and 68% women. The clinical sample was made up of 32.7%, whereas 67.3% had no known problem. To obtain evidence of convergent validity, other questionnaires related to the self (EPQ-R, DES, RSES) were used for comparison. The EOSS showed high internal consistency (Cronbach's α = .941) and significantly high correlations with the EPQ-R Neuroticism scale and the DES Dissociation scale, while showing negative correlations with the Rosenberg Self-Esteem Scale (RSES). The EOSS revealed 4 principal factors: a self in close relationships, a self with casual social relationships, a self in general and a positive self-concept. Significant statistical differences were found between the clinical and standard sample, the former showing a higher average. The EOSS had high internal consistency, showing evidence of convergent validity with similar scales and proving useful for the assessment of people with psychological problems related to the self.
Vandekerckhove, Kristof; Seidl, Andreas; Gutka, Hiten; Kumar, Manish; Gratzl, Gyöngyi; Keire, David; Coffey, Todd; Kuehne, Henriette
2018-05-10
Leading regulatory agencies recommend biosimilar assessment to proceed in a stepwise fashion, starting with a detailed analytical comparison of the structural and functional properties of the proposed biosimilar and reference product. The degree of analytical similarity determines the degree of residual uncertainty that must be addressed through downstream in vivo studies. Substantive evidence of similarity from comprehensive analytical testing may justify a targeted clinical development plan, and thus enable a shorter path to licensing. The importance of a careful design of the analytical similarity study program therefore should not be underestimated. Designing a state-of-the-art analytical similarity study meeting current regulatory requirements in regions such as the USA and EU requires a methodical approach, consisting of specific steps that far precede the work on the actual analytical study protocol. This white paper discusses scientific and methodological considerations on the process of attribute and test method selection, criticality assessment, and subsequent assignment of analytical measures to US FDA's three tiers of analytical similarity assessment. Case examples of selection of critical quality attributes and analytical methods for similarity exercises are provided to illustrate the practical implementation of the principles discussed.
Simões, Rodrigo Almeida; Bonato, Pierina Sueli; Mirnaghi, Fatemeh S; Bojko, Barbara; Pawliszyn, Janusz
2015-01-01
A high-throughput bioanalytical method using 96-blade thin film microextraction (TFME) and LC-MS/MS for the analysis of repaglinide (RPG) and two of its main metabolites was developed and used for an in vitro metabolism study. The target analytes were extracted from human microsomal medium by a 96-blade-TFME system employing the low-cost prototype 'SPME multi-sampler' using C18 coating. Method validation showed recoveries around 90% for all analytes and was linear over the concentration range of 2-1000 ng ml(-1) for RPG and of 2-500 ng ml(-1) for each RPG metabolite. The method was applied to an in vitro metabolism study of RPG employing human liver microsomes and proved to be very useful for this purpose.
An Analytical Model of Joule Heating in Piezoresistive Microcantilevers
Ansari, Mohd Zahid; Cho, Chongdu
2010-01-01
The present study investigates Joule heating in piezoresistive microcantilever sensors. Joule heating and thermal deflections are a major source of noise in such sensors. This work uses analytical and numerical techniques to characterise the Joule heating in 4-layer piezoresistive microcantilevers made of silicon and silicon dioxide substrates but with the same U-shaped silicon piezoresistor. A theoretical model for predicting the temperature generated due to Joule heating is developed. The commercial finite element software ANSYS Multiphysics was used to study the effect of electrical potential on temperature and deflection produced in the cantilevers. The effect of piezoresistor width on Joule heating is also studied. Results show that Joule heating strongly depends on the applied potential and width of piezoresistor and that a silicon substrate cantilever has better thermal characteristics than a silicon dioxide cantilever. PMID:22163433
An analytical model of joule heating in piezoresistive microcantilevers.
Ansari, Mohd Zahid; Cho, Chongdu
2010-01-01
The present study investigates Joule heating in piezoresistive microcantilever sensors. Joule heating and thermal deflections are a major source of noise in such sensors. This work uses analytical and numerical techniques to characterise the Joule heating in 4-layer piezoresistive microcantilevers made of silicon and silicon dioxide substrates but with the same U-shaped silicon piezoresistor. A theoretical model for predicting the temperature generated due to Joule heating is developed. The commercial finite element software ANSYS Multiphysics was used to study the effect of electrical potential on temperature and deflection produced in the cantilevers. The effect of piezoresistor width on Joule heating is also studied. Results show that Joule heating strongly depends on the applied potential and width of piezoresistor and that a silicon substrate cantilever has better thermal characteristics than a silicon dioxide cantilever.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.
Xie, Weizhen; Cappiello, Marcus; Meng, Ming; Rosenthal, Robert; Zhang, Weiwei
2018-05-08
This meta-analytical review examines whether a deletion variant in ADRA2B, a gene that encodes α 2B adrenoceptor in the regulation of norepinephrine availability, influences cognitive processing of emotional information in human observers. Using a multilevel modeling approach, this meta-analysis of 16 published studies with a total of 2,752 participants showed that ADRA2B deletion variant was significantly associated with enhanced perceptual and cognitive task performance for emotional stimuli. In contrast, this genetic effect did not manifest in overall task performance when non-emotional content was used. Furthermore, various study-level factors, such as targeted cognitive processes (memory vs. attention/perception) and task procedures (recall vs. recognition), could moderate the size of this genetic effect. Overall, with increased statistical power and standardized analytical procedures, this meta-analysis has established the contributions of ADRA2B to the interactions between emotion and cognition, adding to the growing literature on individual differences in attention, perception, and memory for emotional information in the general population. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ajami, Sima; Ketabi, Saeedeh
2012-06-01
Medical Records Department (MRD) is an important unit for evaluating and planning of care services. The goal of this study is evaluating the performance of the Medical Records Departments (MRDs) of the selected hospitals in Isfahan, Iran by using Analytical Hierarchy Process (AHP). This was an analytic of cross-sectional study that was done in spring 2008 in Isfahan, Iran. The statistical population consisted of MRDs of Alzahra, Kashani and Khorshid Hospitals in Isfahan. Data were collected by forms and through brainstorm technique. To analyze and perform AHP, Expert Choice software was used by researchers. Results were showed archiving unit has received the largest importance weight with respect to information management. However, on customer aspect admission unit has received the largest weight. Ordering weights of Medical Records Departments' Alzahra, Kashani and Khorshid Hospitals in Isfahan were with 0.394, 0.342 and 0.264 respectively. It is useful for managers to allocate and prioritize resources according to AHP technique for ranking at the Medical Records Departments.
On synchronization in power-grids modelled as networks of second-order Kuramoto oscillators
NASA Astrophysics Data System (ADS)
Grzybowski, J. M. V.; Macau, E. E. N.; Yoneyama, T.
2016-11-01
This work concerns analytical results on the role of coupling strength in the phenomenon of onset of complete frequency locking in power-grids modelled as a network of second-order Kuramoto oscillators. Those results allow estimation of the coupling strength for the onset of complete frequency locking and to assess the features of network and oscillators that favor synchronization. The analytical results are evaluated using an order parameter defined as the normalized sum of absolute values of phase deviations of the oscillators over time. The investigation of the frequency synchronization within the subsets of the parameter space involved in the synchronization problem is also carried out. It is shown that the analytical results are in good agreement with those observed in the numerical simulations. In order to illustrate the methodology, a case study is presented, involving the Brazilian high-voltage transmission system under a load peak condition to study the effect of load on the syncronizability of the grid. The results show that both the load and the centralized generation might have concurred to the 2014 blackout.
An analytical study of the endoreversible Curzon-Ahlborn cycle for a non-linear heat transfer law
NASA Astrophysics Data System (ADS)
Páez-Hernández, Ricardo T.; Portillo-Díaz, Pedro; Ladino-Luna, Delfino; Ramírez-Rojas, Alejandro; Pacheco-Paez, Juan C.
2016-01-01
In the present article, an endoreversible Curzon-Ahlborn engine is studied by considering a non-linear heat transfer law, particularly the Dulong-Petit heat transfer law, using the `componendo and dividendo' rule as well as a simple differentiation to obtain the Curzon-Ahlborn efficiency as proposed by Agrawal in 2009. This rule is actually a change of variable that simplifies a two-variable problem to a one-variable problem. From elemental calculus, we obtain an analytical expression of efficiency and the power output. The efficiency is given only in terms of the temperatures of the reservoirs, such as both Carnot and Curzon-Ahlborn cycles. We make a comparison between efficiencies measured in real power plants and theoretical values from analytical expressions obtained in this article and others found in literature from several other authors. This comparison shows that the theoretical values of efficiency are close to real efficiency, and in some cases, they are exactly the same. Therefore, we can say that the Agrawal method is good in calculating thermal engine efficiencies approximately.
Ammar, Hafedh Belhadj; Brahim, Mabrouk Ben; Abdelhédi, Ridha; Samet, Youssef
2016-02-01
The performance of boron-doped diamond (BDD) electrode for the detection of metronidazole (MTZ) as the most important drug of the group of 5-nitroimidazole was proven using cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques. A comparison study between BDD, glassy carbon and silver electrodes on the electrochemical response was carried out. The process is pH-dependent. In neutral and alkaline media, one irreversible reduction peak related to the hydroxylamine derivative formation was registered, involving a total of four electrons. In acidic medium, a prepeak appears probably related to the adsorption affinity of hydroxylamine at the electrode surface. The BDD electrode showed higher sensitivity and reproducibility analytical response, compared with the other electrodes. The higher reduction peak current was registered at pH11. Under optimal conditions, a linear analytical curve was obtained for the MTZ concentration in the range of 0.2-4.2μmolL(-1), with a detection limit of 0.065μmolL(-1). Copyright © 2015 Elsevier B.V. All rights reserved.
Propagation of propeller tone noise through a fuselage boundary layer
NASA Technical Reports Server (NTRS)
Hanson, D. B.; Magliozzi, B.
1984-01-01
In earlier experimental and analytical studies, it was found that the boundary layer on an aircraft could provide significant shielding from propeller noise at typical transport airplane cruise Mach numbers. In this paper a new three-dimensional theory is described that treats the combined effects of refraction and scattering by the fuselage and boundary layer. The complete wave field is solved by matching analytical expressions for the incident and scattered waves in the outer flow to a numerical solution in the boundary layer flow. The model for the incident waves is a near-field frequency-domain propeller source theory developed previously for free field studies. Calculations for an advanced turboprop (Prop-Fan) model flight test at 0.8 Mach number show a much smaller than expected pressure amplification at the noise directivity peak, strong boundary layer shielding in the forward quadrant, and shadowing around the fuselage. Results are presented showing the difference between fuselage surface and free-space noise predictions as a function of frequency and Mach number. Comparison of calculated and measured effects obtained in a Prop-Fan model flight test show good agreement, particularly near and aft of the plane of rotation at high cruise Mach number.
Gevaerd, Ava; de Oliveira, Paulo R; Mangrich, Antonio S; Bergamini, Márcio F; Marcolino-Junior, Luiz H
2016-05-01
This work describes the construction and application of carbon paste electrodes modified with biochar and antimony microparticles (SbBCPE) for voltammetric determination of paraquat using a simple and sensitive procedure based on voltammetric stripping analysis. Some parameters such as amount of biochar and antimony used in the composition of the carbon paste and instrumental parameters were examined in detail. Under optimized conditions, an analytical curve was obtained for paraquat determination employing SbBCPE, which showed a linear response ranging from 0.2 to 2.9 μmol L(-1), with limit of detection and quantification of 34 nmol L(-1) and 113 nmol L(-1), respectively, after paraquat pre-concentration of 120 s. The repeatability study presented a RSD=2.0% for 10 consecutive measurements using the same electrode surface and the reproducibility study showed a RSD=2.7% for measurements with 10 different electrode surfaces. The proposed sensor was successfully applied for paraquat determination in tap water and citric fruit juice spiked samples and good recoveries were obtained without any sample pre-treatment, showing its promising analytical performance. Copyright © 2016 Elsevier B.V. All rights reserved.
The acoustics of ducted propellers
NASA Astrophysics Data System (ADS)
Ali, Sherif F.
The return of the propeller to the long haul commercial service may be rapidly approaching in the form of advanced "prop fans". It is believed that the advanced turboprop will considerably reduce the operational cost. However, such aircraft will come into general use only if their noise levels meet the standards of community acceptability currently applied to existing aircraft. In this work a time-marching boundary-element technique is developed, and used to study the acoustics of ducted propeller. The numerical technique is developed in this work eliminated the inherent instability suffered by conventional approaches. The methodology is validated against other numerical and analytical results. The results show excellent agreement with the analytical solution and show no indication of unstable behavior. For the ducted propeller problem, the propeller is modeled by a rotating source-sink pairs, and the duct is modeled by rigid annular body of elliptical cross-section. Using the model and the developed technique, the effect of different parameters on the acoustic field is predicted and analyzed. This includes the effect of duct length, propeller axial location, and source Mach number. The results of this study show that installing a short duct around the propeller can reduce the noise that reaches an observer on a side line.
Salivary pH, calcium, phosphorus and selected enzymes in healthy dogs: a pilot study.
Iacopetti, Ilaria; Perazzi, Anna; Badon, Tamara; Bedin, Silvia; Contiero, Barbara; Ricci, Rebecca
2017-11-10
Saliva in dogs, as in humans, is a complex fluid secreted by different salivary glands in the oral cavity to protect the oral mucosa and teeth. The use of saliva as a substitute for blood in diagnosing and prognosticating disease in humans is widely accepted. Salivary biochemistry has also been used as a marker for periodontal disease in humans. No studies have as yet investigated the relation between salivary biochemistry and periodontal disease in dogs, however; neither has the salivary composition of healthy dogs with no oral disease been assessed. The purpose of this study was to obtain an overview on pH distribution and a set of salivary biochemical analytes (calcium, phosphorus, lactate dehydrogenase, lysozyme and amylase) commonly related to oral health in humans in a subset population of healthy young dogs with no periodontal disease or previous oral disease. Data were analyzed to gather salivary reference ranges for pH and each parameter and to assess a possible correlation between salivary and serum analytes. Twenty-nine adult client-owned dogs were recruited for the study. Lactate dehydrogenase and lysozyme showed higher concentrations in saliva than in serum, whereas amylase showed the contrary. Salivary biochemistry values did not differ between males and females or between non-neutered and neutered individuals. No significant correlations between salivary and serum calcium, phosphorus, lactate dehydrogenase, amylase and lysozyme were identified in this study. Data allowed intervals for the salivary pH and other analytes investigated to be obtained from healthy dogs with healthy oral conditions. These preliminary data can contribute to enlarge our understanding of the functional role of saliva and its relation to oral health in dogs.
A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.
Yang, Harry; Zhang, Jianchun
2015-01-01
The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current methods. Analytical methods are often used to ensure safety, efficacy, and quality of medicinal products. According to government regulations and regulatory guidelines, these methods need to be validated through well-designed studies to minimize the risk of accepting unsuitable methods. This article describes a novel statistical test for analytical method validation, which provides better protection for the risk of accepting unsuitable analytical methods. © PDA, Inc. 2015.
Moreno, Daniela; Berli, Federico; Bottini, Rubén; Piccoli, Patricia N; Silva, María F
2017-09-01
Soluble carbohydrates distribution depends on plant physiology and, among other important factors, determines fruit yield and quality. In plant biology, the analysis of sugars is useful for many purposes, including metabolic studies. Capillary electrophoresis (CE) proved to be a powerful green separation technique with minimal sample preparation, even in complex plant tissues, that can provide high-resolution efficiency. Matrix effect refers to alterations in the analytical response caused by components of a sample other than the analyte of interest. Thus, the assessment and reduction of the matrix factor is fundamental for metabolic studies in different matrices. The present study evaluated the source and levels of matrix effects in the determination of most abundant sugars in grapevine tissues (mature and young leaves, berries and roots) at two phenological growth stages. Sucrose was the sugar that showed the least matrix effects, while fructose was the most affected analyte. Based on plant tissues, young leaves presented the smaller matrix effects, irrespectively of the phenology. These changes may be attributed to considerable differences at chemical composition of grapevine tissues with plant development. Therefore, matrix effect should be an important concern for plant metabolomics. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Ultrasonic guided waves in eccentric annular pipes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pattanayak, Roson Kumar; Balasubramaniam, Krishnan; Rajagopal, Prabhu
2014-02-18
This paper studies the feasibility of using ultrasonic guided waves to rapidly inspect tubes and pipes for possible eccentricity. While guided waves are well established in the long range inspection of structures such as pipes and plates, studies for more complex cross sections are limited and analytical solutions are often difficult to obtain. Recent developments have made the Semi Analytical Finite Element (SAFE) method widely accessible for researchers to study guided wave properties in complex structures. Here the SAFE method is used to study the effect of eccentricity on the modal structures and velocities of lower order guided wave modesmore » in thin pipes of diameters typically of interest to the industry. Results are validated using experiments. The paper demonstrates that even a small eccentricity in the pipe can strongly affect guided wave mode structures and velocities and hence shows potential for pipe eccentricity inspection.« less
Small Business. Lesson Plan Three.
ERIC Educational Resources Information Center
Dicke, Thomas S.
1996-01-01
Presents a lesson plan that requires students to use their research and analytical skills in studying the social and economic importance of small business. Activities include interviewing local business owners and producing a written summary, developing a survey showing and explaining area land use, and researching opposition to Wal-Mart stores.…
After Analysis: A Study of Transference Dreams Following Treatment.
ERIC Educational Resources Information Center
Carlson, Rae
1986-01-01
Examined posttreatment consolidation of experience with a script-theoretic analysis of transference dreams. A content-analytic scheme applied to three during-treatment and three posttreatment dreams showed in posttreatment dreams a significant increase in positive affects, a decrease in negative affects, and more effective initatives by the…
A realistic chemical system presenting a self-organized critical behavior
NASA Astrophysics Data System (ADS)
Gaveau, Bernard; Latrémolière, Daniel; Moreau, Michel
2003-04-01
We consider a realistic example of chemical system which presents self-organized criticality. We can study the kinetic equations analytically, and show that the conditions for self-organized criticality are satisfied. We find power relaxation laws for certain variables near the critical state, confirming the self-organized critical behavior.
Unemployment Impairs Mental Health: Meta-Analyses
ERIC Educational Resources Information Center
Paul, Karsten I.; Moser, Klaus
2009-01-01
The effect of unemployment on mental health was examined with meta-analytic methods across 237 cross-sectional and 87 longitudinal studies. The average overall effect size was d = 0.51 with unemployed persons showing more distress than employed persons. A significant difference was found for several indicator variables of mental health (mixed…
Conditions for synchronization in Josephson-junction arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chernikov, A.A.; Schmidt, G.
An effective perturbation theoretical method has been developed to study the dynamics of Josephson Junction series arrays. It is shown that the inclusion of Junction capacitances, often ignored, has a significant impact on synchronization. Comparison of analytic with computational results over a wide range of parameters shows excellent agreement.
Li, Zhigang; Ji, Cheng; Wang, Lishu
2018-07-01
Although analytical models have been used to quickly predict head response under impact condition, the existing models generally took the head as regular shell with uniform thickness which cannot account for the actual head geometry with varied cranial thickness and curvature at different locations. The objective of this study is to develop and validate an analytical model incorporating actual cranial thickness and curvature for child aged 0-1YO and investigate their effects on child head dynamic responses at different head locations. To develop the new analytical model, the child head was simplified into an irregular fluid-filled shell with non-uniform thickness and the cranial thickness and curvature at different locations were automatically obtained from CT scans using a procedure developed in this study. The implicit equation of maximum impact force was derived as a function of elastic modulus, thickness and radius of curvature of cranium. The proposed analytical model are compared with cadaver test data of children aged 0-1 years old and it is shown to be accurate in predicting head injury metrics. According to this model, obvious difference in injury metrics were observed among subjects with the same age, but different cranial thickness and curvature; and the injury metrics at forehead location are significant higher than those at other locations due to large thickness it owns. The proposed model shows good biofidelity and can be used in quickly predicting the dynamics response at any location of head for child younger than 1 YO. Copyright © 2018 Elsevier B.V. All rights reserved.
Human Capital Analytics to Manage the Army Officer Population
2017-06-09
employees from spending time and energy on a career path projected to be obsolete. Instead, managers are able to use data to show employees where they...HUMAN CAPITAL ANALYTICS TO MANAGE THE ARMY OFFICER POPULATION A thesis presented to the Faculty of the U.S. Army Command and...From - To) AUG 2016 – JUNE 2017 4. TITLE AND SUBTITLE Human Capital Analytics to Manage the Army Officer Population 5a. CONTRACT NUMBER 5b
Waaijer, Cathelijn J F; Palmblad, Magnus
2015-01-01
In this Feature we use automatic bibliometric mapping tools to visualize the history of analytical chemistry from the 1920s until the present. In particular, we have focused on the application of mass spectrometry in different fields. The analysis shows major shifts in research focus and use of mass spectrometry. We conclude by discussing the application of bibliometric mapping and visualization tools in analytical chemists' research.
NASA Astrophysics Data System (ADS)
Folgueira, M.; Souchay, J.
2005-03-01
The purpose of this paper is to show how to solve in Hamiltonian formalism the equations of the polar motion of any arbitrarily shaped elastic celestial body, i.e. the motion of its rotation axis (or angular momentum) with respect to its figure axis. With this aim, we deduce from canonical equations related to the rotational Hamiltonian of the body, the analytical solution for its free polar motion which depends both on the elasticity and on its moments of inertia. In particular, we study the influence of the phase angle δ, responsible for the dissipation, on the damping of the polar motion. In order to validate our analytical equations, we show that, to first order, they are in complete agreement with those obtained from the classical Liouville equations. Then we adapt our calculations to the real data obtained from the polar motion of the Earth (polhody). For that purpose, we characterize precisely the differences in radius J-χ and in angle l-θ between the polar coordinates (χ,θ) and (J,l) representing respectively the motion of the axis of rotation of the Earth and the motion of its angular momentum axis, with respect to an Earth-fixed reference frame, after showing the influence of the choice of the origin on these coordinates, and on the determination of the Chandler period as well. Then we show that the phase lag δ responsible for the damping for the selected time interval, between Feb. 1982 and Apr. 1990, might be of the order of δ ≈ 6 °, according to a numerical integration starting from our analytical equations. Moreover, we emphasize the presence in our calculations for both χ and θ, of an oscillation with a period TChandler/2, due to the triaxial shape of our planet, and generally not taken into account. In a last step, we apply our analytical formulation to the polar motion of Mars, thus showing the high dependence of its damping on the poorly known value of its Love number k. Moreover we emphasize the large oscillations of Mars' polar motion due to the triaxiality of this planet.
What is the right formalism to search for resonances?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mikhasenko, M.; Pilloni, A.; Nys, J.
Hmore » adron decay chains constitute one of the main sources of information on the QCD spectrum. We discuss the differences between several partial wave analysis formalisms used in the literature to build the amplitudes. We match the helicity amplitudes to the covariant tensor basis. ereby, we pay attention to the analytical properties of the amplitudes and separate singularities of kinematical and dynamical nature. We study the analytical properties of the spin-orbit (LS) formalism, and some of the covariant tensor approaches. In particular, we explicitly build the amplitudes for the B → ψ π K and B → D ¯ π π decays, and show that the energy dependence of the covariant approach is model dependent. We also show that the usual recursive construction of covariant tensors explicitly violates crossing symmetry, which would lead to different resonance parameters extracted from scattering and decay processes.« less
What is the right formalism to search for resonances?
Mikhasenko, M.; Pilloni, A.; Nys, J.; ...
2018-03-17
Hmore » adron decay chains constitute one of the main sources of information on the QCD spectrum. We discuss the differences between several partial wave analysis formalisms used in the literature to build the amplitudes. We match the helicity amplitudes to the covariant tensor basis. ereby, we pay attention to the analytical properties of the amplitudes and separate singularities of kinematical and dynamical nature. We study the analytical properties of the spin-orbit (LS) formalism, and some of the covariant tensor approaches. In particular, we explicitly build the amplitudes for the B → ψ π K and B → D ¯ π π decays, and show that the energy dependence of the covariant approach is model dependent. We also show that the usual recursive construction of covariant tensors explicitly violates crossing symmetry, which would lead to different resonance parameters extracted from scattering and decay processes.« less
The effect of damping on a quantum system containing a Kerr-like medium
NASA Astrophysics Data System (ADS)
Mohamed, A.-B. A.; Sebawe Abdalla, M.; Obada, A.-S. F.
2018-05-01
An analytical description is given for a model which represents the interaction between Su(1,1) and Su(2) quantum systems taking into account Su(1,1)-cavity damping and Kerr medium properties. The analytic solution for the master equation of the density matrix is obtained. The examination of the effects of the damping parameter as well as the Kerr-like medium features is performed. The atomic inversion is discussed where the revivals and collapses phenomenon is realized at the considered period of time. Our study is extended to include the degree of entanglement where the system shows partial entanglement in all cases, however, disentanglement is also observed. The death and rebirth is seen in the system provided one selects the suitable values of the parameters. The correlation function of the system shows non-classical as well as classical behavior.
Bilingual Voicing: A Study of Code-Switching in the Reported Speech of Finnish Immigrants in Estonia
ERIC Educational Resources Information Center
Frick, Maria; Riionheimo, Helka
2013-01-01
Through a conversation analytic investigation of Finnish-Estonian bilingual (direct) reported speech (i.e., voicing) by Finns who live in Estonia, this study shows how code-switching is used as a double contextualization device. The code-switched voicings are shaped by the on-going interactional situation, serving its needs by opening up a context…
ERIC Educational Resources Information Center
Alqahtani, Abdulmuhsen Ayedh; Almutairi, Yousef B.
2013-01-01
The purpose of the current study is to examine, in retrospect, trainees' perceptions of the reasons some of their peers dropped out of the vocational education at the Industrial Institute-Shuwaikh (IIS), Kuwait. Using the descriptive-analytical method, a reliable questionnaire was developed to achieve this purpose. Results show that: (a) the…
A sample preparation method for recovering suppressed analyte ions in MALDI TOF MS.
Lou, Xianwen; de Waal, Bas F M; Milroy, Lech-Gustav; van Dongen, Joost L J
2015-05-01
In matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS), analyte signals can be substantially suppressed by other compounds in the sample. In this technical note, we describe a modified thin-layer sample preparation method that significantly reduces the analyte suppression effect (ASE). In our method, analytes are deposited on top of the surface of matrix preloaded on the MALDI plate. To prevent embedding of analyte into the matrix crystals, the sample solution were prepared without matrix and efforts were taken not to re-dissolve the preloaded matrix. The results with model mixtures of peptides, synthetic polymers and lipids show that detection of analyte ions, which were completely suppressed using the conventional dried-droplet method, could be effectively recovered by using our method. Our findings suggest that the incorporation of analytes in the matrix crystals has an important contributory effect on ASE. By reducing ASE, our method should be useful for the direct MALDI MS analysis of multicomponent mixtures. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Kawamura, E.; Lieberman, M. A.; Graves, D. B.
2014-12-01
A fast 2D axisymmetric fluid-analytical plasma reactor model using the finite elements simulation tool COMSOL is interfaced with a 1D particle-in-cell (PIC) code to study ion energy distributions (IEDs) in multi-frequency capacitive argon discharges. A bulk fluid plasma model, which solves the time-dependent plasma fluid equations for the ion continuity and electron energy balance, is coupled with an analytical sheath model, which solves for the sheath parameters. The time-independent Helmholtz equation is used to solve for the fields and a gas flow model solves for the steady-state pressure, temperature and velocity of the neutrals. The results of the fluid-analytical model are used as inputs to a PIC simulation of the sheath region of the discharge to obtain the IEDs at the target electrode. Each 2D fluid-analytical-PIC simulation on a moderate 2.2 GHz CPU workstation with 8 GB of memory took about 15-20 min. The multi-frequency 2D fluid-analytical model was compared to 1D PIC simulations of a symmetric parallel-plate discharge, showing good agreement. We also conducted fluid-analytical simulations of a multi-frequency argon capacitively coupled plasma (CCP) with a typical asymmetric reactor geometry at 2/60/162 MHz. The low frequency 2 MHz power controlled the sheath width and sheath voltage while the high frequencies controlled the plasma production. A standing wave was observable at the highest frequency of 162 MHz. We noticed that adding 2 MHz power to a 60 MHz discharge or 162 MHz to a dual frequency 2 MHz/60 MHz discharge can enhance the plasma uniformity. We found that multiple frequencies were not only useful for controlling IEDs but also plasma uniformity in CCP reactors.
Three-dimensional eddy current solution of a polyphase machine test model (abstract)
NASA Astrophysics Data System (ADS)
Pahner, Uwe; Belmans, Ronnie; Ostovic, Vlado
1994-05-01
This abstract describes a three-dimensional (3D) finite element solution of a test model that has been reported in the literature. The model is a basis for calculating the current redistribution effects in the end windings of turbogenerators. The aim of the study is to see whether the analytical results of the test model can be found using a general purpose finite element package, thus indicating that the finite element model is accurate enough to treat real end winding problems. The real end winding problems cannot be solved analytically, as the geometry is far too complicated. The model consists of a polyphase coil set, containing 44 individual coils. This set generates a two pole mmf distribution on a cylindrical surface. The rotating field causes eddy currents to flow in the inner massive and conducting rotor. In the analytical solution a perfect sinusoidal mmf distribution is put forward. The finite element model contains 85824 tetrahedra and 16451 nodes. A complex single scalar potential representation is used in the nonconducting parts. The computation time required was 3 h and 42 min. The flux plots show that the field distribution is acceptable. Furthermore, the induced currents are calculated and compared with the values found from the analytical solution. The distribution of the eddy currents is very close to the distribution of the analytical solution. The most important results are the losses, both local and global. The value of the overall losses is less than 2% away from those of the analytical solution. Also the local distribution of the losses is at any given point less than 7% away from the analytical solution. The deviations of the results are acceptable and are partially due to the fact that the sinusoidal mmf distribution was not modeled perfectly in the finite element method.
New hybrid voxelized/analytical primitive in Monte Carlo simulations for medical applications
NASA Astrophysics Data System (ADS)
Bert, Julien; Lemaréchal, Yannick; Visvikis, Dimitris
2016-05-01
Monte Carlo simulations (MCS) applied in particle physics play a key role in medical imaging and particle therapy. In such simulations, particles are transported through voxelized phantoms derived from predominantly patient CT images. However, such voxelized object representation limits the incorporation of fine elements, such as artificial implants from CAD modeling or anatomical and functional details extracted from other imaging modalities. In this work we propose a new hYbrid Voxelized/ANalytical primitive (YVAN) that combines both voxelized and analytical object descriptions within the same MCS, without the need to simultaneously run two parallel simulations, which is the current gold standard methodology. Given that YVAN is simply a new primitive object, it does not require any modifications on the underlying MC navigation code. The new proposed primitive was assessed through a first simple MCS. Results from the YVAN primitive were compared against an MCS using a pure analytical geometry and the layer mass geometry concept. A perfect agreement was found between these simulations, leading to the conclusion that the new hybrid primitive is able to accurately and efficiently handle phantoms defined by a mixture of voxelized and analytical objects. In addition, two application-based evaluation studies in coronary angiography and intra-operative radiotherapy showed that the use of YVAN was 6.5% and 12.2% faster than the layered mass geometry method, respectively, without any associated loss of accuracy. However, the simplification advantages and differences in computational time improvements obtained with YVAN depend on the relative proportion of the analytical and voxelized structures used in the simulation as well as the size and number of triangles used in the description of the analytical object meshes.
Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T
2017-01-01
Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient performance when compared to CrCl. Although clinicians should be aware of applying a GFR formula that is compatible with the locally used analytical method for determining Cys C and creatinine, other factors might be more crucial for the calculation of correct GFR values.
NASA Astrophysics Data System (ADS)
Sergeev, A. A.; Leonov, A. A.; Kamenev, D. G.; Voznesenskii, S. S.; Kul'chin, Yu. M.
2017-09-01
We have studied the properties of luminescent protein complexes based on myoglobin with covalently bound CY3 luminophore, which were incorporated into polysaccharide agarose films, as potential elements sensitive to hydrogen sulfide (H2S) in aqueous solutions. The presence of this analyte changes the absorption spectrum of myoglobin, which influences the efficiency of luminophore excitation while having almost no effect on its emission spectrum. This effect shows that a luminescent sensor system with the optical response determined by analyte-induced changes in the efficiency of luminescence excitation in the sensitive element can be created. For the system studied, the limit of detection of H2S dissolved in water amounted to 100 pM.
Gupta, A; Joshi, A Y; Sharma, S C; Harsha, S P
2012-09-01
In the present study, the vibrations of the fixed-free single-walled carbon nanotube (SWCNT) with attached bacterium/virus on the tip have been investigated. To explore the suitability of the SWCNT as a bacterium/virus detector device, first the various types of virus have been taken for the study and then the resonant frequencies of fixed-free SWCNT with attachment of those viruses have been simulated. These resonant frequencies are compared with the published analytical data, and it is shown that the finite element method (FEM) simulation results are in good agreement with the analytical data. The results showed the sensitivity and suitability of the SWCNT having different length and different masses (attached at the tip SWCNT) to identify the bacterium or virus.
Kinks in higher derivative scalar field theory
NASA Astrophysics Data System (ADS)
Zhong, Yuan; Guo, Rong-Zhen; Fu, Chun-E.; Liu, Yu-Xiao
2018-07-01
We study static kink configurations in a type of two-dimensional higher derivative scalar field theory whose Lagrangian contains second-order derivative terms of the field. The linear fluctuation around arbitrary static kink solutions is analyzed. We find that, the linear spectrum can be described by a supersymmetric quantum mechanics problem, and the criteria for stable static solutions can be given analytically. We also construct a superpotential formalism for finding analytical static kink solutions. Using this formalism we first reproduce some existed solutions and then offer a new solution. The properties of our solution is studied and compared with those preexisted. We also show the possibility in constructing twinlike model in the higher derivative theory, and give the consistency conditions for twinlike models corresponding to the canonical scalar field theory.
Functionally Graded Adhesives for Composite Joints
NASA Technical Reports Server (NTRS)
Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.
2012-01-01
Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.
General monogamy of Tsallis q -entropy entanglement in multiqubit systems
NASA Astrophysics Data System (ADS)
Luo, Yu; Tian, Tian; Shao, Lian-He; Li, Yongming
2016-06-01
In this paper, we study the monogamy inequality of Tsallis q -entropy entanglement. We first provide an analytic formula of Tsallis q -entropy entanglement in two-qubit systems for 5/-√{13 } 2 ≤q ≤5/+√{13 } 2 . The analytic formula of Tsallis q -entropy entanglement in 2 ⊗d system is also obtained and we show that Tsallis q -entropy entanglement satisfies a set of hierarchical monogamy equalities. Furthermore, we prove the squared Tsallis q -entropy entanglement follows a general inequality in the qubit systems. Based on the monogamy relations, a set of multipartite entanglement indicators is constructed, which can detect all genuine multiqubit entangled states even in the case of N -tangle vanishes. Moreover, we study some examples in multipartite higher-dimensional system for the monogamy inequalities.
NASA Astrophysics Data System (ADS)
Spitoni, E.; Vincenzo, F.; Matteucci, F.
2017-03-01
Context. Analytical models of chemical evolution, including inflow and outflow of gas, are important tools for studying how the metal content in galaxies evolves as a function of time. Aims: We present new analytical solutions for the evolution of the gas mass, total mass, and metallicity of a galactic system when a decaying exponential infall rate of gas and galactic winds are assumed. We apply our model to characterize a sample of local star-forming and passive galaxies from the Sloan Digital Sky Survey data, with the aim of reproducing their observed mass-metallicity relation. Methods: We derived how the two populations of star-forming and passive galaxies differ in their particular distribution of ages, formation timescales, infall masses, and mass loading factors. Results: We find that the local passive galaxies are, on average, older and assembled on shorter typical timescales than the local star-forming galaxies; on the other hand, the star-forming galaxies with higher masses generally show older ages and longer typical formation timescales compared than star-forming galaxies with lower masses. The local star-forming galaxies experience stronger galactic winds than the passive galaxy population. Exploring the effect of assuming different initial mass functions in our model, we show that to reproduce the observed mass-metallicity relation, stronger winds are requested if the initial mass function is top-heavy. Finally, our analytical models predict the assumed sample of local galaxies to lie on a tight surface in the 3D space defined by stellar metallicity, star formation rate, and stellar mass, in agreement with the well-known fundamental relation from adopting gas-phase metallicity. Conclusions: By using a new analytical model of chemical evolution, we characterize an ensemble of SDSS galaxies in terms of their infall timescales, infall masses, and mass loading factors. Local passive galaxies are, on average, older and assembled on shorter typical timescales than the local star-forming galaxies. Moreover, the local star-forming galaxies show stronger galactic winds than the passive galaxy population. Finally, we find that the fundamental relation between metallicity, mass, and star formation rate for these local galaxies is still valid when adopting the average galaxy stellar metallicity.
Wang, Xiaogang; Qi, Meiling; Fu, Ruonong
2014-12-05
Here we report the separation performance of a new stationary phase of cucurbit[7]uril (CB7) incorporated into an ionic liquid-based sol-gel coating (CB7-SG) for capillary gas chromatography (GC). The CB7-SG stationary phase showed an average polarity of 455, suggesting its polar nature. Abraham system constants revealed that its major interactions with analytes include H-bond basicity (a), dipole-dipole (s) and dispersive (l) interactions. The CB7-SG stationary phase achieved baseline separation for a wide range of analytes with symmetrical peak shapes and showed advantages over the conventional polar stationary phase that failed to resolve some critical analytes. Also, it exhibited different retention behaviors from the conventional stationary phase in terms of retention times and elution order. Most interestingly, in contrast to the conventional polar phase, the CB7-SG stationary phase exhibited longer retentions for analytes of lower polarity but relatively comparable retentions for polar analytes such as alcohols and phenols. The high resolving ability and unique retention behaviors of the CB7-SG stationary phase may stem from the comprehensive interactions of the aforementioned interactions and shape selectivity. Moreover, the CB7-SG column showed good peak shapes for analytes prone to peak tailing, good thermal stability up to 280°C and separation repeatability with RSD values in the range of 0.01-0.11% for intra-day, 0.04-0.41% for inter-day and 2.5-6.0% for column-to-column, respectively. As demonstrated, the proposed coating method can simultaneously address the solubility problem with CBs for the intended purpose and achieve outstanding GC separation performance. Copyright © 2014 Elsevier B.V. All rights reserved.
The Framework of Intervention Engine Based on Learning Analytics
ERIC Educational Resources Information Center
Sahin, Muhittin; Yurdugül, Halil
2017-01-01
Learning analytics primarily deals with the optimization of learning environments and the ultimate goal of learning analytics is to improve learning and teaching efficiency. Studies on learning analytics seem to have been made in the form of adaptation engine and intervention engine. Adaptation engine studies are quite widespread, but intervention…
Olmos, José Manuel; Molina, Ángela; Laborda, Eduardo; Millán-Barrios, Enrique; Ortuño, Joaquín Ángel
2018-02-06
A new theory is presented to tackle the study of transfer processes of hydrophilic ions in two polarizable interface systems when the analyte is initially present in both aqueous phases. The treatment is applied to macrointerfaces (linear diffusion) and microholes (highly convergent diffusion), obtaining analytical equations for the current response in any voltammetric technique. The novel equations predict two signals in the current-potential curves that are symmetric when the compositions of the aqueous phases are identical while asymmetries appear otherwise. The theoretical results show good agreement with the experimental behavior of the "double transfer voltammograms" reported by Dryfe et al. in cyclic voltammetry (CV) ( Anal. Chem. 2014 , 86 , 435 - 442 ) as well as with cyclic square wave voltammetry (cSWV) experiments performed in the current work. The theoretical treatment is also extended to the situation where the target ion is lipophilic and initially present in the organic phase. The theory predicts an opposite effect of the lipophilicity of the ion on the shape of the voltammograms, which is validated experimentally via both CV and cSWV. For the above two cases, simple and manageable expressions and diagnosis criteria are derived for the qualitative and quantitative study of ion lipophilicity. The ion-transfer potentials can be easily quantified from the separation between the two signals making use of explicit analytical equations.
NASA Astrophysics Data System (ADS)
Hosseini-Hashemi, Shahrokh; Sepahi-Boroujeni, Amin; Sepahi-Boroujeni, Saeid
2018-04-01
Normal impact performance of a system including a fullerene molecule and a single-layered graphene sheet is studied in the present paper. Firstly, through a mathematical approach, a new contact law is derived to describe the overall non-bonding interaction forces of the "hollow indenter-target" system. Preliminary verifications show that the derived contact law gives a reliable picture of force field of the system which is in good agreements with the results of molecular dynamics (MD) simulations. Afterwards, equation of the transversal motion of graphene sheet is utilized on the basis of both the nonlocal theory of elasticity and the assumptions of classical plate theory. Then, to derive dynamic behavior of the system, a set including the proposed contact law and the equations of motion of both graphene sheet and fullerene molecule is solved numerically. In order to evaluate outcomes of this method, the problem is modeled by MD simulation. Despite intrinsic differences between analytical and MD methods as well as various errors arise due to transient nature of the problem, acceptable agreements are established between analytical and MD outcomes. As a result, the proposed analytical method can be reliably used to address similar impact problems. Furthermore, it is found that a single-layered graphene sheet is capable of trapping fullerenes approaching with low velocities. Otherwise, in case of rebound, the sheet effectively absorbs predominant portion of fullerene energy.
Briot, T; Robelet, A; Morin, N; Riou, J; Lelièvre, B; Lebelle-Dehaut, A-V
2016-07-01
In this study, a novel analytical method to quantify prion inactivating detergent in rinsing waters coming from the washer-disinfector of a hospital sterilization unit has been developed. The final aim was to obtain an easy and functional method in a routine hospital process which does not need the cleaning product manufacturer services. An ICP-MS method based on the potassium dosage of the washer-disinfector's rinsing waters was developed. Potassium hydroxide is present on the composition of the three prion inactivating detergent currently on the French market. The detergent used in this study was the Actanios LDI(®) (Anios laboratories). A Passing and Bablok regression compares concentrations measured with this developed method and with the HPLC-UV manufacturer method. According to results obtained, the developed method is easy to use in a routine hospital process. The Passing and Bablok regression showed that there is no statistical difference between the two analytical methods during the second rinsing step. Besides, both methods were linear on the third rinsing step, with a 1.5ppm difference between the concentrations measured for each method. This study shows that the ICP-MS method developed is nonspecific for the detergent, but specific for the potassium element which is present in all prion inactivating detergent currently on the French market. This method should be functional for all the prion inactivating detergent containing potassium, if the sensibility of the method is sufficient when the potassium concentration is very low in the prion inactivating detergent formulation. Copyright © 2016. Published by Elsevier Masson SAS.
Sterkers, Yvon; Varlet-Marie, Emmanuelle; Cassaing, Sophie; Brenier-Pinchart, Marie-Pierre; Brun, Sophie; Dalle, Frédéric; Delhaes, Laurence; Filisetti, Denis; Pelloux, Hervé; Yera, Hélène; Bastien, Patrick
2010-01-01
Although screening for maternal toxoplasmic seroconversion during pregnancy is based on immunodiagnostic assays, the diagnosis of clinically relevant toxoplasmosis greatly relies upon molecular methods. A problem is that this molecular diagnosis is subject to variation of performances, mainly due to a large diversity of PCR methods and primers and the lack of standardization. The present multicentric prospective study, involving eight laboratories proficient in the molecular prenatal diagnosis of toxoplasmosis, was a first step toward the harmonization of this diagnosis among university hospitals in France. Its aim was to compare the analytical performances of different PCR protocols used for Toxoplasma detection. Each center extracted the same concentrated Toxoplasma gondii suspension and tested serial dilutions of the DNA using its own assays. Differences in analytical sensitivities were observed between assays, particularly at low parasite concentrations (≤2 T. gondii genomes per reaction tube), with “performance scores” differing by a 20-fold factor among laboratories. Our data stress the fact that differences do exist in the performances of molecular assays in spite of expertise in the matter; we propose that laboratories work toward a detection threshold defined for a best sensitivity of this diagnosis. Moreover, on the one hand, intralaboratory comparisons confirmed previous studies showing that rep529 is a more adequate DNA target for this diagnosis than the widely used B1 gene. But, on the other hand, interlaboratory comparisons showed differences that appear independent of the target, primers, or technology and that hence rely essentially on proficiency and care in the optimization of PCR conditions. PMID:20610670
Feedback topology and XOR-dynamics in Boolean networks with varying input structure
NASA Astrophysics Data System (ADS)
Ciandrini, L.; Maffi, C.; Motta, A.; Bassetti, B.; Cosentino Lagomarsino, M.
2009-08-01
We analyze a model of fixed in-degree random Boolean networks in which the fraction of input-receiving nodes is controlled by the parameter γ . We investigate analytically and numerically the dynamics of graphs under a parallel XOR updating scheme. This scheme is interesting because it is accessible analytically and its phenomenology is at the same time under control and as rich as the one of general Boolean networks. We give analytical formulas for the dynamics on general graphs, showing that with a XOR-type evolution rule, dynamic features are direct consequences of the topological feedback structure, in analogy with the role of relevant components in Kauffman networks. Considering graphs with fixed in-degree, we characterize analytically and numerically the feedback regions using graph decimation algorithms (Leaf Removal). With varying γ , this graph ensemble shows a phase transition that separates a treelike graph region from one in which feedback components emerge. Networks near the transition point have feedback components made of disjoint loops, in which each node has exactly one incoming and one outgoing link. Using this fact, we provide analytical estimates of the maximum period starting from topological considerations.
A numerical test of the topographic bias
NASA Astrophysics Data System (ADS)
Sjöberg, L. E.; Joud, M. S. S.
2018-02-01
In 1962 A. Bjerhammar introduced the method of analytical continuation in physical geodesy, implying that surface gravity anomalies are downward continued into the topographic masses down to an internal sphere (the Bjerhammar sphere). The method also includes analytical upward continuation of the potential to the surface of the Earth to obtain the quasigeoid. One can show that also the common remove-compute-restore technique for geoid determination includes an analytical continuation as long as the complete density distribution of the topography is not known. The analytical continuation implies that the downward continued gravity anomaly and/or potential are/is in error by the so-called topographic bias, which was postulated by a simple formula of L E Sjöberg in 2007. Here we will numerically test the postulated formula by comparing it with the bias obtained by analytical downward continuation of the external potential of a homogeneous ellipsoid to an inner sphere. The result shows that the postulated formula holds: At the equator of the ellipsoid, where the external potential is downward continued 21 km, the computed and postulated topographic biases agree to less than a millimetre (when the potential is scaled to the unit of metre).
Feedback topology and XOR-dynamics in Boolean networks with varying input structure.
Ciandrini, L; Maffi, C; Motta, A; Bassetti, B; Cosentino Lagomarsino, M
2009-08-01
We analyze a model of fixed in-degree random Boolean networks in which the fraction of input-receiving nodes is controlled by the parameter gamma. We investigate analytically and numerically the dynamics of graphs under a parallel XOR updating scheme. This scheme is interesting because it is accessible analytically and its phenomenology is at the same time under control and as rich as the one of general Boolean networks. We give analytical formulas for the dynamics on general graphs, showing that with a XOR-type evolution rule, dynamic features are direct consequences of the topological feedback structure, in analogy with the role of relevant components in Kauffman networks. Considering graphs with fixed in-degree, we characterize analytically and numerically the feedback regions using graph decimation algorithms (Leaf Removal). With varying gamma , this graph ensemble shows a phase transition that separates a treelike graph region from one in which feedback components emerge. Networks near the transition point have feedback components made of disjoint loops, in which each node has exactly one incoming and one outgoing link. Using this fact, we provide analytical estimates of the maximum period starting from topological considerations.
The 2D analytic signal for envelope detection and feature extraction on ultrasound images.
Wachinger, Christian; Klein, Tassilo; Navab, Nassir
2012-08-01
The fundamental property of the analytic signal is the split of identity, meaning the separation of qualitative and quantitative information in form of the local phase and the local amplitude, respectively. Especially the structural representation, independent of brightness and contrast, of the local phase is interesting for numerous image processing tasks. Recently, the extension of the analytic signal from 1D to 2D, covering also intrinsic 2D structures, was proposed. We show the advantages of this improved concept on ultrasound RF and B-mode images. Precisely, we use the 2D analytic signal for the envelope detection of RF data. This leads to advantages for the extraction of the information-bearing signal from the modulated carrier wave. We illustrate this, first, by visual assessment of the images, and second, by performing goodness-of-fit tests to a Nakagami distribution, indicating a clear improvement of statistical properties. The evaluation is performed for multiple window sizes and parameter estimation techniques. Finally, we show that the 2D analytic signal allows for an improved estimation of local features on B-mode images. Copyright © 2012 Elsevier B.V. All rights reserved.
Effect of risk perception on epidemic spreading in temporal networks
NASA Astrophysics Data System (ADS)
Moinet, Antoine; Pastor-Satorras, Romualdo; Barrat, Alain
2018-01-01
Many progresses in the understanding of epidemic spreading models have been obtained thanks to numerous modeling efforts and analytical and numerical studies, considering host populations with very different structures and properties, including complex and temporal interaction networks. Moreover, a number of recent studies have started to go beyond the assumption of an absence of coupling between the spread of a disease and the structure of the contacts on which it unfolds. Models including awareness of the spread have been proposed, to mimic possible precautionary measures taken by individuals that decrease their risk of infection, but have mostly considered static networks. Here, we adapt such a framework to the more realistic case of temporal networks of interactions between individuals. We study the resulting model by analytical and numerical means on both simple models of temporal networks and empirical time-resolved contact data. Analytical results show that the epidemic threshold is not affected by the awareness but that the prevalence can be significantly decreased. Numerical studies on synthetic temporal networks highlight, however, the presence of very strong finite-size effects, resulting in a significant shift of the effective epidemic threshold in the presence of risk awareness. For empirical contact networks, the awareness mechanism leads as well to a shift in the effective threshold and to a strong reduction of the epidemic prevalence.
Melero-Ferrer, Josep Lluís; Osa-Sáez, Ana; Buendía-Fuentes, Francisco; Ballesta-Cuñat, Antonio; Flors, Lucía; Rodríguez-Serrano, María; Calvillo-Batllés, Pilar; Arnau-Vives, Miguel-Ángel; Palencia-Pérez, Miguel A; Rueda-Soriano, Joaquín
2014-07-01
The development of liver fibrosis and cirrhosis due to long-standing liver congestion is known to occur in adult patients with Fontan circulation. Hepatic elastography has shown to be a useful tool for the noninvasive assessment and staging of liver fibrosis in chronic liver diseases, although the utility of this technique in Fontan patients remains to be adequately studied. Twenty-one patients with Fontan circulation underwent an abdominal ultrasound and an acoustic radiation force impulse (ARFI) elastography. In order to compare the results from this group, a cohort of 14 healthy controls and another group containing 17 patients with cirrhosis were included. The association between the velocity values measured with elastography and clinical and analytical parameters were also studied. Mean shear waves propagation velocity in liver tissue in the Fontan group was 1.86 ± 0.5 m/s, with 76% of patients over the cirrhosis threshold (1.55 m/s). The control group had a mean velocity of 1.09 ± 0.06 m/s, while the cirrhotic group obtained 2.71 ± 0.51 m/s. Seven patients with Fontan circulation had increased liver enzymes. Liver ultrasound showed evidence of chronic liver disease in six patients. Velocity values obtained in the presence or absence of analytical or liver ultrasound abnormalities showed significant differences in the univariate analysis (P = .04 and P = .03 respectively). In conclusion, ARFI elastography showed increased wave propagation velocity values in the Fontan population suggesting increased liver stiffness which could be related to advanced fibrosis. A statistically significant association between ARFI values and the presence of analytical and ultrasound abnormalities has been demonstrated. © The Author(s) 2014.
Miller, Tyler M; Geraci, Lisa
2016-05-01
People may change their memory predictions after retrieval practice using naïve theories of memory and/or by using subjective experience - analytic and non-analytic processes respectively. The current studies disentangled contributions of each process. In one condition, learners studied paired-associates, made a memory prediction, completed a short-run of retrieval practice and made a second prediction. In another condition, judges read about a yoked learners' retrieval practice performance but did not participate in retrieval practice and therefore, could not use non-analytic processes for the second prediction. In Study 1, learners reduced their predictions following moderately difficult retrieval practice whereas judges increased their predictions. In Study 2, learners made lower adjusted predictions than judges following both easy and difficult retrieval practice. In Study 3, judge-like participants used analytic processes to report adjusted predictions. Overall, the results suggested non-analytic processes play a key role for participants to reduce their predictions after retrieval practice. Copyright © 2016 Elsevier Inc. All rights reserved.
On the Stefan Problem with Volumetric Energy Generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
John Crepeau; Ali Siahpush; Blaine Spotten
2009-11-01
This paper presents results of solid-liquid phase change, driven by volumetric energy generation, in a vertical cylinder. We show excellent agreement between a quasi-static, approximate analytical solution valid for Stefan numbers less than one, and a computational model solved using the CFD code FLUENT®. A computational study also shows the effect that the volumetric energy generation has on both the mushy zone thickness and convection in the melt during phase change.
The Effectiveness of Digital Game-Based Vocabulary Learning: A Framework-Based View of Meta-Analysis
ERIC Educational Resources Information Center
Chen, Meng-Hua; Tseng, Wen-Ta; Hsiao, Tsung-Yuan
2018-01-01
This study presents the results of a meta-analytic study about the effects of digital game-based learning (DGBL) on vocabulary. The results of the study showed that the effects of DGBL on vocabulary learning may vary with game design features (Q = 5.857, df = 1, p = 0.016), but not with learners' age (Q = 0.906, df = 1, p = 0.341) or linguistic…
An analytic data analysis method for oscillatory slug tests.
Chen, Chia-Shyun
2006-01-01
An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.
The I/O transform of a chemical sensor
Katta, Nalin; Meier, Douglas C.; Benkstein, Kurt D.; Semancik, Steve; Raman, Baranidharan
2016-01-01
A number of sensing technologies, using a variety of transduction principles, have been proposed for non-invasive chemical sensing. A fundamental problem common to all these sensing technologies is determining what features of the transducer's signal constitute a chemical fingerprint that allows for precise analyte recognition. Of particular importance is the need to extract features that are robust with respect to the sensor's age or stimulus intensity. Here, using pulsed stimulus delivery, we show that a sensor's operation can be modeled as a linear input-output (I/O) transform. The I/O transform is unique for each analyte and can be used to precisely predict a temperature-programmed chemiresistor's response to the analyte given the recent stimulus history (i.e. state of an analyte delivery valve being open or closed). We show that the analyte specific I/O transforms are to a certain degree stimulus intensity invariant and can remain consistent even when the sensor has undergone considerable aging. Significantly, the I/O transforms for a given analyte are highly conserved across sensors of equal manufacture, thereby allowing training data obtained from one sensor to be used for recognition of the same set of chemical species with another sensor. Hence, this proposed approach facilitates decoupling of the signal processing algorithms from the chemical transducer, a key advance necessary for achieving long-term, non-invasive chemical sensing. PMID:27932855
Analytical equation for outflow along the flow in a perforated fluid distribution pipe
Liu, Huanfang; Lv, Hongxing; Jin, Jin
2017-01-01
Perforated fluid distribution pipes have been widely used in agriculture, water supply and drainage, ventilation, the chemical industry, and other sectors. The momentum equation for variable mass flow with a variable exchange coefficient and variable friction coefficient was developed by using the momentum conservation method under the condition of a certain slope. The change laws of the variable momentum exchange coefficient and the variable resistance coefficient along the flow were analyzed, and the function of the momentum exchange coefficient was given. According to the velocity distribution of the power function, the momentum equation of variable mass flow was solved for different Reynolds numbers. The analytical solution contains components of pressure, gravity, friction and momentum and reflects the influence of various factors on the pressure distribution along the perforated pipe. The calculated results of the analytical solution were compared with the experimental values of the study by Jin et al. 1984 and Wang et al. 2001 with the mean errors 8.2%, 3.8% and 2.7%, and showed that the analytical solution of the variable mass momentum equation was qualitatively and quantitatively consistent with the experimental results. PMID:29065112
Predictive classification of self-paced upper-limb analytical movements with EEG.
Ibáñez, Jaime; Serrano, J I; del Castillo, M D; Minguez, J; Pons, J L
2015-11-01
The extent to which the electroencephalographic activity allows the characterization of movements with the upper limb is an open question. This paper describes the design and validation of a classifier of upper-limb analytical movements based on electroencephalographic activity extracted from intervals preceding self-initiated movement tasks. Features selected for the classification are subject specific and associated with the movement tasks. Further tests are performed to reject the hypothesis that other information different from the task-related cortical activity is being used by the classifiers. Six healthy subjects were measured performing self-initiated upper-limb analytical movements. A Bayesian classifier was used to classify among seven different kinds of movements. Features considered covered the alpha and beta bands. A genetic algorithm was used to optimally select a subset of features for the classification. An average accuracy of 62.9 ± 7.5% was reached, which was above the baseline level observed with the proposed methodology (30.2 ± 4.3%). The study shows how the electroencephalography carries information about the type of analytical movement performed with the upper limb and how it can be decoded before the movement begins. In neurorehabilitation environments, this information could be used for monitoring and assisting purposes.
Aeroelastic loads and stability investigation of a full-scale hingeless rotor
NASA Technical Reports Server (NTRS)
Peterson, Randall L.; Johnson, Wayne
1991-01-01
An analytical investigation was conducted to study the influence of various parameters on predicting the aeroelastic loads and stability of a full-scale hingeless rotor in hover and forward flight. The CAMRAD/JA (Comprehensive Analytical Model of Rotorcraft Aerodynamics and Dynamics, Johnson Aeronautics) analysis code is used to obtain the analytical predictions. Data are presented for rotor blade bending and torsional moments as well as inplane damping data obtained for rotor operation in hover at a constant rotor rotational speed of 425 rpm and thrust coefficients between 0.0 and 0.12. Experimental data are presented from a test in the wind tunnel. Validation of the rotor system structural model with experimental rotor blade loads data shows excellent correlation with analytical results. Using this analysis, the influence of different aerodynamic inflow models, the number of generalized blade and body degrees of freedom, and the control-system stiffness at predicted stability levels are shown. Forward flight predictions of the BO-105 rotor system for 1-G thrust conditions at advance ratios of 0.0 to 0.35 are presented. The influence of different aerodynamic inflow models, dynamic inflow models and shaft angle variations on predicted stability levels are shown as a function of advance ratio.
The relationship between schizotypal facets and conspiracist beliefs via cognitive processes.
Barron, David; Furnham, Adrian; Weis, Laura; Morgan, Kevin D; Towell, Tony; Swami, Viren
2018-01-01
This study sought to replicate previous work showing relationships between components of schizotypy and conspiracist beliefs, and extend it by examining the mediating role of cognitive processes. An international online sample of 411 women and men (mean age = 35.41 years) completed measures of the schizotypal facets of Odd Beliefs or Magical Thinking and Ideas of Reference, conspiracist beliefs, and cognitive processes related to need for cognition, analytic thinking, and cognitive insight. Path analysis confirmed the associations between both schizotypal facets and conspiracist beliefs in the present sample. Confirmatory evidence was found for the association between analytic thinking and conspiracist beliefs, and results also suggested an association between cognitive insight and conspiracist beliefs. Cognitive insight also mediated the link between Odd Beliefs or Magical Thinking and Ideas of Reference with conspiracist beliefs. However, analytic thinking provided a mediating link to conspiracy ideation for Odd Beliefs or Magical Thinking and not Ideas of Reference. Finally, there was an association between Odd Beliefs or Magical Thinking and need for cognition, but this path did not extend to conspiracist beliefs. These results suggest possible mediating roles for analytic thinking and self-certainty between schizotypy and conspiracist beliefs. Copyright © 2017 Elsevier B.V. All rights reserved.
Collisional evolution - an analytical study for the nonsteady-state mass distribution
NASA Astrophysics Data System (ADS)
Martins, R. Vieira
1999-05-01
To study the collisional evolution of asteroidal groups we can use an analytical solutionfor the self-similar collision cascades. This solution is suitable to study the steady-state massdistribution of the collisional fragmentation. However, out of the steady-state conditions, thissolution is not satisfactory for some values of the collisional parameters. In fact, for some valuesfor the exponent of the mass distribution power law of an asteroidal group and its relation to theexponent of the function which describes how rocks break we arrive at singular points for theequation which describes the collisional evolution. These singularities appear since someapproximations are usually made in the laborious evaluation of many integrals that appear in theanalytical calculations. They concern the cutoff for the smallest and the largest bodies. Thesesingularities set some restrictions to the study of the analytical solution for the collisionalequation. To overcome these singularities we performed an algebraic computationconsidering the smallest and the largest bodies and we obtained the analytical expressions for theintegrals that describe the collisional evolution without restriction on the parameters. However,the new distribution is more sensitive to the values of the collisional parameters. In particular thesteady-state solution for the differential mass distribution has exponents slightly different from11⧸6 for the usual parameters in the Asteroid Belt. The sensitivity of this distribution with respectto the parameters is analyzed for the usual values in the asteroidal groups. With anexpression for the mass distribution without singularities, we can evaluate also its time evolution.We arrive at an analytical expression given by a power series of terms constituted by a smallparameter multiplied by the mass to an exponent, which depends on the initial power lawdistribution. This expression is a formal solution for the equation which describes the collisionalevolution. Furthermore, the first-order term for this solution is the time rate of the distribution atthe initial time. In particular the solution shows the fundamental importance played by theexponent of the power law initial condition in the evolution of the system.
Mendes, Michele P Rocha; Silveira, Josianne Nicácio; Andre, Leiliane Coelho
2017-09-15
Benzene is an important occupational and environmental contaminant, naturally present in petroleum and as by-product in the steel industry. Toxicological studies showed pronounced myelotoxic action, causing leukemic and others blood cells disorders. Assessing of benzene exposure is performed by biomarkers as trans, trans-muconic acid (AttM) and S-phenylmercapturic acid (S-PMA) in urine. Due to specificity of S-PMA, this biomarker has been proposed to asses lower levels of benzene in air. The aim of this study was to validate an analytical method for the quantification of S-PMA by High-Performance Liquid Chromatography with fluorometric detector. The development of an analytical method of S-PMA in urine was carried out by solid phase extraction (SPE) using C-18 phase. The eluated were submitted to water bath at 75°C and nitrogen to analyte concentration, followed by alkaline hydrolysis and derivatization with monobromobimane. The chromatography conditions were reverse phase C-18 column (240mm, 4mm and 5μm) at 35°C; acetonitrile and 0.5% acetic acid (50:50) as mobile phase with a flow of 0.8mL/min. The limits of detection and quantification were 0.22μg/L and 0.68μg/L, respectively. The linearity was verified by simple linear regression, and the method exhibited good linearity in the range of 10-100μg/L. There was no matrix effect for S-PMA using concentrations of 40, 60, 80 and 100μg/L. The intra- and interassay precision showed coefficient of variation of less than 10% and the recovery ranged from 83.4 to 102.8% with an average of 94.4%. The stability of S-PMA in urine stored at -20°C was of seven weeks. The conclusion is that this method presents satisfactory results per their figures of merit. This proposed method for determining urinary S-PMA showed adequate sensitivity for assessment of occupational and environmental exposure to benzene using S-PMA as biomarker of exposure. Copyright © 2017 Elsevier B.V. All rights reserved.
Analytical Chemists: A New Breed of Entrepreneurs.
ERIC Educational Resources Information Center
Analytical Chemistry, 1985
1985-01-01
Examines the involvement of college faculty in small business activities, indicating that university administrators have become decidedly more supportive of such ventures in recent years. A list of 14 start-up companies (showing type of services) founded recently by university analytical chemists is included. (JN)
Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms
NASA Astrophysics Data System (ADS)
Zhang, Guofeng; Zhu, Hanjie
2015-03-01
The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.
Analytical solution for the anisotropic Rabi model: effects of counter-rotating terms.
Zhang, Guofeng; Zhu, Hanjie
2015-03-04
The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.
Rapid ultrasensitive single particle surface-enhanced Raman spectroscopy using metallic nanopores.
Cecchini, Michael P; Wiener, Aeneas; Turek, Vladimir A; Chon, Hyangh; Lee, Sangyeop; Ivanov, Aleksandar P; McComb, David W; Choo, Jaebum; Albrecht, Tim; Maier, Stefan A; Edel, Joshua B
2013-10-09
Nanopore sensors embedded within thin dielectric membranes have been gaining significant interest due to their single molecule sensitivity and compatibility of detecting a large range of analytes, from DNA and proteins, to small molecules and particles. Building on this concept we utilize a metallic Au solid-state membrane to translocate and rapidly detect single Au nanoparticles (NPs) functionalized with 589 dye molecules using surface-enhanced resonance Raman spectroscopy (SERRS). We show that, due to the plasmonic coupling between the Au metallic nanopore surface and the NP, signal intensities are enhanced when probing analyte molecules bound to the NP surface. Although not single molecule, this nanopore sensing scheme benefits from the ability of SERRS to provide rich vibrational information on the analyte, improving on current nanopore-based electrical and optical detection techniques. We show that the full vibrational spectrum of the analyte can be detected with ultrahigh spectral sensitivity and a rapid temporal resolution of 880 μs.
Cobb, Zoe; Sellergren, Börje; Andersson, Lars I
2007-12-01
Two novel molecularly imprinted polymers (MIPs) selected from a combinatorial library of bupivacaine imprinted polymers were used for selective on-line solid-phase extraction of bupivacaine and ropivacaine from human plasma. The MIPs were prepared using methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linking monomer and in addition hydroxyethylmethacrylate to render the polymer surface hydrophilic. The novel MIPs showed high selectivity for the analytes and required fewer and lower concentrations of additives to suppress non-specific adsorption compared with a conventional MIP. This enabled the development of an on-line system for direct extraction of buffered plasma. Selective extraction was achieved without the use of time-consuming solvent switch steps, and transfer of the analytes from the MIP column to the analytical column was carried out under aqueous conditions fully compatible with reversed-phase LC gradient separation of analyte and internal standard. The MIPs showed excellent aqueous compatibility and yielded extractions with acceptable recovery and high selectivity.
Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms
Zhang, Guofeng; Zhu, Hanjie
2015-01-01
The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model. PMID:25736827
Analytical Studies on the Synchronization of a Network of Linearly-Coupled Simple Chaotic Systems
NASA Astrophysics Data System (ADS)
Sivaganesh, G.; Arulgnanam, A.; Seethalakshmi, A. N.; Selvaraj, S.
2018-05-01
We present explicit generalized analytical solutions for a network of linearly-coupled simple chaotic systems. Analytical solutions are obtained for the normalized state equations of a network of linearly-coupled systems driven by a common chaotic drive system. Two parameter bifurcation diagrams revealing the various hidden synchronization regions, such as complete, phase and phase-lag synchronization are identified using the analytical results. The synchronization dynamics and their stability are studied using phase portraits and the master stability function, respectively. Further, experimental results for linearly-coupled simple chaotic systems are presented to confirm the analytical results. The synchronization dynamics of a network of chaotic systems studied analytically is reported for the first time.
Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Shimizu, Yoshihisa; Xia, Liangyu; Hoffmann, Mariza; Shah, Swarup; Matsha, Tandi; Wassung, Janette; Smit, Francois; Ruzhanskaya, Anna; Straseski, Joely; Bustos, Daniel N; Kimura, Shogo; Takahashi, Aki
2017-04-01
The intent of this study, based on a global multicenter study of reference values (RVs) for serum analytes was to explore biological sources of variation (SVs) of the RVs among 12 countries around the world. As described in the first part of this paper, RVs of 50 major serum analytes from 13,396 healthy individuals living in 12 countries were obtained. Analyzed in this study were 23 clinical chemistry analytes and 8 analytes measured by immunoturbidimetry. Multiple regression analysis was performed for each gender, country by country, analyte by analyte, by setting four major SVs (age, BMI, and levels of drinking and smoking) as a fixed set of explanatory variables. For analytes with skewed distributions, log-transformation was applied. The association of each source of variation with RVs was expressed as the partial correlation coefficient (r p ). Obvious gender and age-related changes in the RVs were observed in many analytes, almost consistently between countries. Compilation of age-related variations of RVs after adjusting for between-country differences revealed peculiar patterns specific to each analyte. Judged fromthe r p , BMI related changes were observed for many nutritional and inflammatory markers in almost all countries. However, the slope of linear regression of BMI vs. RV differed greatly among countries for some analytes. Alcohol and smoking-related changes were observed less conspicuously in a limited number of analytes. The features of sex, age, alcohol, and smoking-related changes in RVs of the analytes were largely comparable worldwide. The finding of differences in BMI-related changes among countries in some analytes is quite relevant to understanding ethnic differences in susceptibility to nutritionally related diseases. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Samborski, Sylwester; Valvo, Paolo S.
2018-01-01
The paper deals with the numerical and analytical modelling of the end-loaded split test for multi-directional laminates affected by the typical elastic couplings. Numerical analysis of three-dimensional finite element models was performed with the Abaqus software exploiting the virtual crack closure technique (VCCT). The results show possible asymmetries in the widthwise deflections of the specimen, as well as in the strain energy release rate (SERR) distributions along the delamination front. Analytical modelling based on a beam-theory approach was also conducted in simpler cases, where only bending-extension coupling is present, but no out-of-plane effects. The analytical results matched the numerical ones, thus demonstrating that the analytical models are feasible for test design and experimental data reduction.
Thermodynamics of Gas Turbine Cycles with Analytic Derivatives in OpenMDAO
NASA Technical Reports Server (NTRS)
Gray, Justin; Chin, Jeffrey; Hearn, Tristan; Hendricks, Eric; Lavelle, Thomas; Martins, Joaquim R. R. A.
2016-01-01
A new equilibrium thermodynamics analysis tool was built based on the CEA method using the OpenMDAO framework. The new tool provides forward and adjoint analytic derivatives for use with gradient based optimization algorithms. The new tool was validated against the original CEA code to ensure an accurate analysis and the analytic derivatives were validated against finite-difference approximations. Performance comparisons between analytic and finite difference methods showed a significant speed advantage for the analytic methods. To further test the new analysis tool, a sample optimization was performed to find the optimal air-fuel equivalence ratio, , maximizing combustion temperature for a range of different pressures. Collectively, the results demonstrate the viability of the new tool to serve as the thermodynamic backbone for future work on a full propulsion modeling tool.
Chapman, Peter J; Vogt, Frank; Dutta, Pampa; Datskos, Panos G; Devault, Gerald L; Sepaniak, Michael J
2007-01-01
The very simple coupling of a standard, packed-column gas chromatograph with a microcantilever array (MCA) is demonstrated for enhanced selectivity and potential analyte identification in the analysis of volatile organic compounds (VOCs). The cantilevers in MCAs are differentially coated on one side with responsive phases (RPs) and produce bending responses of the cantilevers due to analyte-induced surface stresses. Generally, individual components are difficult to elucidate when introduced to MCA systems as mixtures, although pattern recognition techniques are helpful in identifying single components, binary mixtures, or composite responses of distinct mixtures (e.g., fragrances). In the present work, simple test VOC mixtures composed of acetone, ethanol, and trichloroethylene (TCE) in pentane and methanol and acetonitrile in pentane are first separated using a standard gas chromatograph and then introduced into a MCA flow cell. Significant amounts of response diversity to the analytes in the mixtures are demonstrated across the RP-coated cantilevers of the array. Principal component analysis is used to demonstrate that only three components of a four-component VOC mixture could be identified without mixture separation. Calibration studies are performed, demonstrating a good linear response over 2 orders of magnitude for each component in the primary study mixture. Studies of operational parameters including column temperature, column flow rate, and array cell temperature are conducted. Reproducibility studies of VOC peak areas and peak heights are also carried out showing RSDs of less than 4 and 3%, respectively, for intra-assay studies. Of practical significance is the facile manner by which the hyphenation of a mature separation technique and the burgeoning sensing approach is accomplished, and the potential to use pattern recognition techniques with MCAs as a new type of detector for chromatography with analyte-identifying capabilities.
de Graaf, P; Vos, R M; de Boer, N H K; Sinjewel, A; Jharap, B; Mulder, C J J; van Bodegraven, A A; Veldkamp, A I
2010-06-01
Monitoring of thiopurine metabolites 6-thioguanine nucleotides (6-TGN) and 6-methylmercaptopurine (6-MMP) is used to assess compliance and explain adverse reactions in IBD-patients. Correlations between dosage, metabolite concentrations and therapeutic efficacy or toxicity are contradictive. Research is complicated by analytical problems as matrices analyzed and analytical procedures vary widely. Moreover, stability of thiopurine metabolites is not well documented, yet pivotal for interpretation of analytical outcomes. Therefore, we prospectively investigated metabolite stability in blood samples under standard storage conditions. Stability at room temperature and refrigeration (22 degrees C, 4 degrees C) was investigated during 1 week and frozen samples (-20 degrees C, -80 degrees C) were analyzed during 6 months storage. Ten patient samples were analyzed for each study period. Median 6-TGN concentrations on day 7 decreased significantly to 53% and 90% during storage at ambient temperature or refrigeration. Median 6-MMP concentrations on day 7 decreased significantly to 55% and 86%, respectively. Samples stored at -20 degrees C also showed significant decreases in both 6-TGN and 6-MMP in comparison with baseline values. At -80 degrees C, only 6-MMP showed a significant decrease in values compared to baseline. The stability of thiopurine metabolites is clearly a limiting factor in studies investigating utilisation of TDM and correlations with therapeutic outcome in IBD-patients. This has to be accounted for in clinical practice and (multi-center) trials investigating thiopurine drugs. Copyright 2010. Published by Elsevier B.V.
SeeDB: Efficient Data-Driven Visualization Recommendations to Support Visual Analytics
Vartak, Manasi; Rahman, Sajjadur; Madden, Samuel; Parameswaran, Aditya; Polyzotis, Neoklis
2015-01-01
Data analysts often build visualizations as the first step in their analytical workflow. However, when working with high-dimensional datasets, identifying visualizations that show relevant or desired trends in data can be laborious. We propose SeeDB, a visualization recommendation engine to facilitate fast visual analysis: given a subset of data to be studied, SeeDB intelligently explores the space of visualizations, evaluates promising visualizations for trends, and recommends those it deems most “useful” or “interesting”. The two major obstacles in recommending interesting visualizations are (a) scale: evaluating a large number of candidate visualizations while responding within interactive time scales, and (b) utility: identifying an appropriate metric for assessing interestingness of visualizations. For the former, SeeDB introduces pruning optimizations to quickly identify high-utility visualizations and sharing optimizations to maximize sharing of computation across visualizations. For the latter, as a first step, we adopt a deviation-based metric for visualization utility, while indicating how we may be able to generalize it to other factors influencing utility. We implement SeeDB as a middleware layer that can run on top of any DBMS. Our experiments show that our framework can identify interesting visualizations with high accuracy. Our optimizations lead to multiple orders of magnitude speedup on relational row and column stores and provide recommendations at interactive time scales. Finally, we demonstrate via a user study the effectiveness of our deviation-based utility metric and the value of recommendations in supporting visual analytics. PMID:26779379
Casson, Florence Boux de; Moal, Valérie; Gauchez, Anne-Sophie; Moineau, Marie-Pierre; Sault, Corinne; Schlageter, Marie-Hélène; Massart, Catherine
2017-04-01
The aim of this study was to evaluate the pre-analytical factors contributing to uncertainty in thyroglobulin measurement in fluids from fine-needle aspiration (FNA) washout of cervical lymph nodes. We studied pre-analytical stability, in different conditions, of 41 samples prepared with concentrated solutions of thyroglobulin (FNA washout or certified standard) diluted in physiological saline solution or buffer containing 6% albumin. In this buffer, over time, no changes in thyroglobulin concentrations were observed in all storage conditions tested. In albumin free saline solution, thyroglobulin recovery rates depended on initial sample concentrations and on modalities of their conservation (in conventional storage tubes, recovery mean was 56% after 3 hours-storage at room temperature and 19% after 24 hours-storage for concentrations ranged from 2 to 183 μg/L; recovery was 95%, after 3 hours or 24 hours-storage at room temperature, for a concentration of 5,656 μg/L). We show here that these results are due to non-specific adsorption of thyroglobulin in storage tubes, which depends on sample protein concentrations. We also show that possible contamination of fluids from FNA washout by plasma proteins do not always adequately prevent this adsorption. In conclusion, non-specific adsorption in storage tubes strongly contributes to uncertainty in thyroglobulin measurement in physiological saline solution. It is therefore recommended, for FNA washout, to use a buffer containing proteins provided by the laboratory.
SeeDB: Efficient Data-Driven Visualization Recommendations to Support Visual Analytics.
Vartak, Manasi; Rahman, Sajjadur; Madden, Samuel; Parameswaran, Aditya; Polyzotis, Neoklis
2015-09-01
Data analysts often build visualizations as the first step in their analytical workflow. However, when working with high-dimensional datasets, identifying visualizations that show relevant or desired trends in data can be laborious. We propose SeeDB, a visualization recommendation engine to facilitate fast visual analysis: given a subset of data to be studied, SeeDB intelligently explores the space of visualizations, evaluates promising visualizations for trends, and recommends those it deems most "useful" or "interesting". The two major obstacles in recommending interesting visualizations are (a) scale : evaluating a large number of candidate visualizations while responding within interactive time scales, and (b) utility : identifying an appropriate metric for assessing interestingness of visualizations. For the former, SeeDB introduces pruning optimizations to quickly identify high-utility visualizations and sharing optimizations to maximize sharing of computation across visualizations. For the latter, as a first step, we adopt a deviation-based metric for visualization utility, while indicating how we may be able to generalize it to other factors influencing utility. We implement SeeDB as a middleware layer that can run on top of any DBMS. Our experiments show that our framework can identify interesting visualizations with high accuracy. Our optimizations lead to multiple orders of magnitude speedup on relational row and column stores and provide recommendations at interactive time scales. Finally, we demonstrate via a user study the effectiveness of our deviation-based utility metric and the value of recommendations in supporting visual analytics.
Chan, Siaw Li; Rana, Sarosh; Chinthala, Sireesha; Salahuddin, Saira; Yeo, Kiang-Teck J
2018-01-01
Preeclampsia is one of the leading hypertensive disorders of pregnancy. Angiogenic biomarkers such as anti-angiogenic factor soluble fms-like tyrosine kinase 1 (sFlt1) and pro-angiogenic factor placental growth factor (PlGF) are involved in the pathophysiology of preeclampsia. The aim of this study is to validate the analytical performance of sFlt1 and PlGF on the B·R·A·H·M·S KRYPTOR Compact Plus (ThermoFisher Scientific). We examined K 2 -EDTA plasma samples from 50 patients on B·R·A·H·M·S KRYPTOR Compact Plus, an automated immunoassay platform. QC materials were used to assess intra- and inter-precision of the assay. Lower limit of quantitation and interference studies were determined using pooled patient plasma. The sFlt1 and PlGF assays demonstrated an analytical measuring range of 90-69,000 pg/mL and 11-7000 pg/mL, respectively (r 2 > 0.99). Lower limit of quantitation (20% CV) was interpolated to be 35 pg/mL for sFlt1 and 10 pg/mL for PlGF. Total precision for both assay displayed CVs of <10%. Interference studies showed that both assays were not significantly affected by hemolysis up to an H-index of 1100 for sFlt1 and 300 for PlGF; L- and I-index of 800 and 80 respectively for both assays. The Passing-Bablok regression analysis for sFlt1/PlGF yielded an equation of y = 1.05x + 0.02, and the Bland Altman analysis showed an average bias of 0.84. Plasma levels of sFlt1 and PlGF measured on the B·R·A·H·M·S KRYPTOR Compact Plus platform demonstrate excellent analytical performance and are acceptable as clinical grade assays. Copyright © 2018 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Buerck, John P.; Mudigonda, Srikanth P.
2014-01-01
Academic analytics and learning analytics have been increasingly adopted by academic institutions of higher learning for improving student performance and retention. While several studies have reported the implementation details and the successes of specific analytics initiatives, relatively fewer studies exist in literature that describe the…
Xiao, Jie; Wang, Tianyang; Li, Pei; Liu, Ran; Li, Qing; Bi, Kaishun
2016-08-15
A sensitive, reliable and accurate UHPLC-MS/MS method has been firstly established and validated for the simultaneous quantification of ginkgo flavonoids, terpene lactones and nimodipine in rat plasma after oral administration of Ginkgo biloba dispersible tablets, Nimodipine tablets and the combination of the both, respectively. The plasma samples were extracted by two step liquid-liquid extraction, nimodipine was extracted by hexane-ether (3:1, v/v) at the first step, after that ginkgo flavonoids and terpene lactones were extracted by ethyl acetate. Then the analytes were successfully separated by running gradient elution with the mobile phase consisting of 0.1% formic acid in water and methanol at a flow rate of 0.6mL/min. The detection of the analytes was performed on a UHPLC-MS/MS system with turbo ion spray source in the negative ion and multiple reaction monitoring (MRM) mode. The calibration curves for the determination of all the analytes showed good linearity (R(2)>0.99), and the lower limits of quantification were 0.50-4.00ng/mL. Intra-day and inter-day precisions were in the range of 3.6%-9.2% and 3.2%-13.1% for all the analytes. The mean extraction recoveries of the analytes were within 69.82%-103.5% and the matrix were within 82.8%-110.0%. The validated method had been successfully applied to compare the pharmacokinetic parameters of ginkgo flavonoids, terpene lactones and nimodipine in rat plasma after oral administration of Ginkgo biloba dispersible tablets, Nimodipine tablets with the combination of the both. There were no statistically significant differences on the pharmacokinetic behaviors of all the analytes between the combined and single administration groups. Results showed that the combination of the two agents may avoid dosage adjustments in clinic and the combination is more convenient as well as efficient on different pathogenesis of cerebral ischemia. Copyright © 2016 Elsevier B.V. All rights reserved.
Parr, Maria Kristina; Wuest, Bernhard; Naegele, Edgar; Joseph, Jan F; Wenzel, Maxi; Schmidt, Alexander H; Stanic, Mijo; de la Torre, Xavier; Botrè, Francesco
2016-09-01
HPLC is considered the method of choice for the separation of various classes of drugs. However, some analytes are still challenging as HPLC shows limited resolution capabilities for highly polar analytes as they interact insufficiently on conventional reversed-phase (RP) columns. Especially in combination with mass spectrometric detection, limitations apply for alterations of stationary phases. Some highly polar sympathomimetic drugs and their metabolites showed almost no retention on different RP columns. Their retention remains poor even on phenylhexyl phases that show different selectivity due to π-π interactions. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to HPLC may help to overcome these issues. Selected polar drugs and metabolites were analyzed utilizing SFC separation. All compounds showed sharp peaks and good retention even for the very polar analytes, such as sulfoconjugates. Retention times and elution orders in SFC are different to both RP and HILIC separations as a result of the orthogonality. Short cycle times could be realized. As temperature and pressure strongly influence the polarity of supercritical fluids, precise regulation of temperature and backpressure is required for the stability of the retention times. As CO2 is the main constituent of the mobile phase in SFC, solvent consumption and solvent waste are considerably reduced. Graphical Abstract SFC-MS/MS vs. LC-MS/MS.
Evaluation of an in-practice wet-chemistry analyzer using canine and feline serum samples.
Irvine, Katherine L; Burt, Kay; Papasouliotis, Kostas
2016-01-01
A wet-chemistry biochemical analyzer was assessed for in-practice veterinary use. Its small size may mean a cost-effective method for low-throughput in-house biochemical analyses for first-opinion practice. The objectives of our study were to determine imprecision, total observed error, and acceptability of the analyzer for measurement of common canine and feline serum analytes, and to compare clinical sample results to those from a commercial reference analyzer. Imprecision was determined by within- and between-run repeatability for canine and feline pooled samples, and manufacturer-supplied quality control material (QCM). Total observed error (TEobs) was determined for pooled samples and QCM. Performance was assessed for canine and feline pooled samples by sigma metric determination. Agreement and errors between the in-practice and reference analyzers were determined for canine and feline clinical samples by Bland-Altman and Deming regression analyses. Within- and between-run precision was high for most analytes, and TEobs(%) was mostly lower than total allowable error. Performance based on sigma metrics was good (σ > 4) for many analytes and marginal (σ > 3) for most of the remainder. Correlation between the analyzers was very high for most canine analytes and high for most feline analytes. Between-analyzer bias was generally attributed to high constant error. The in-practice analyzer showed good overall performance, with only calcium and phosphate analyses identified as significantly problematic. Agreement for most analytes was insufficient for transposition of reference intervals, and we recommend that in-practice-specific reference intervals be established in the laboratory. © 2015 The Author(s).
Implicit motor learning promotes neural efficiency during laparoscopy.
Zhu, Frank F; Poolton, Jamie M; Wilson, Mark R; Hu, Yong; Maxwell, Jon P; Masters, Rich S W
2011-09-01
An understanding of differences in expert and novice neural behavior can inform surgical skills training. Outside the surgical domain, electroencephalographic (EEG) coherence analyses have shown that during motor performance, experts display less coactivation between the verbal-analytic and motor planning regions than their less skilled counterparts. Reduced involvement of verbal-analytic processes suggests greater neural efficiency. The authors tested the utility of an implicit motor learning intervention specifically devised to promote neural efficiency by reducing verbal-analytic involvement in laparoscopic performance. In this study, 18 novices practiced a movement pattern on a laparoscopic trainer with either conscious awareness of the movement pattern (explicit motor learning) or suppressed awareness of the movement pattern (implicit motor learning). In a retention test, movement accuracy was compared between the conditions, and coactivation (EEG coherence) was assessed between the motor planning (Fz) region and both the verbal-analytic (T3) and the visuospatial (T4) cortical regions (T3-Fz and T4-Fz, respectively). Movement accuracy in the conditions was not different in a retention test (P = 0.231). Findings showed that the EEG coherence scores for the T3-Fz regions were lower for the implicit learners than for the explicit learners (P = 0.027), but no differences were apparent for the T4-Fz regions (P = 0.882). Implicit motor learning reduced EEG coactivation between verbal-analytic and motor planning regions, suggesting that verbal-analytic processes were less involved in laparoscopic performance. The findings imply that training techniques that discourage nonessential coactivation during motor performance may provide surgeons with more neural resources with which to manage other aspects of surgery.
NASA Astrophysics Data System (ADS)
Chatterjee, D.; Gulminelli, F.; Raduta, Ad. R.; Margueron, J.
2017-12-01
The question of correlations among empirical equation of state (EoS) parameters constrained by nuclear observables is addressed in a Thomas-Fermi meta-modeling approach. A recently proposed meta-modeling for the nuclear EoS in nuclear matter is augmented with a single finite size term to produce a minimal unified EoS functional able to describe the smooth part of the nuclear ground state properties. This meta-model can reproduce the predictions of a large variety of models, and interpolate continuously between them. An analytical approximation to the full Thomas-Fermi integrals is further proposed giving a fully analytical meta-model for nuclear masses. The parameter space is sampled and filtered through the constraint of nuclear mass reproduction with Bayesian statistical tools. We show that this simple analytical meta-modeling has a predictive power on masses, radii, and skins comparable to full Hartree-Fock or extended Thomas-Fermi calculations with realistic energy functionals. The covariance analysis on the posterior distribution shows that no physical correlation is present between the different EoS parameters. Concerning nuclear observables, a strong correlation between the slope of the symmetry energy and the neutron skin is observed, in agreement with previous studies.
Yun Chen; Hui Yang
2014-01-01
The rapid advancements of biomedical instrumentation and healthcare technology have resulted in data-rich environments in hospitals. However, the meaningful information extracted from rich datasets is limited. There is a dire need to go beyond current medical practices, and develop data-driven methods and tools that will enable and help (i) the handling of big data, (ii) the extraction of data-driven knowledge, (iii) the exploitation of acquired knowledge for optimizing clinical decisions. This present study focuses on the prediction of mortality rates in Intensive Care Units (ICU) using patient-specific healthcare recordings. It is worth mentioning that postsurgical monitoring in ICU leads to massive datasets with unique properties, e.g., variable heterogeneity, patient heterogeneity, and time asyncronization. To cope with the challenges in ICU datasets, we developed the postsurgical decision support system with a series of analytical tools, including data categorization, data pre-processing, feature extraction, feature selection, and predictive modeling. Experimental results show that the proposed data-driven methodology outperforms traditional approaches and yields better results based on the evaluation of real-world ICU data from 4000 subjects in the database. This research shows great potentials for the use of data-driven analytics to improve the quality of healthcare services.
Electron cooling of a bunched ion beam in a storage ring
NASA Astrophysics Data System (ADS)
Zhao, He; Mao, Lijun; Yang, Jiancheng; Xia, Jiawen; Yang, Xiaodong; Li, Jie; Tang, Meitang; Shen, Guodong; Ma, Xiaoming; Wu, Bo; Wang, Geng; Ruan, Shuang; Wang, Kedong; Dong, Ziqiang
2018-02-01
A combination of electron cooling and rf system is an effective method to compress the beam bunch length in storage rings. A simulation code based on multiparticle tracking was developed to calculate the bunched ion beam cooling process, in which the electron cooling, intrabeam scattering (IBS), ion beam space-charge field, transverse and synchrotron motion are considered. Meanwhile, bunched ion beam cooling experiments have been carried out in the main cooling storage ring (CSRm) of the Heavy Ion Research Facility in Lanzhou, to investigate the minimum bunch length obtained by the cooling method, and study the dependence of the minimum bunch length on beam and machine parameters. The experiments show comparable results to those from simulation. Based on these simulations and experiments, we established an analytical model to describe the limitation of the bunch length of the cooled ion beam. It is observed that the IBS effect is dominant for low intensity beams, and the space-charge effect is much more important for high intensity beams. Moreover, the particles will not be bunched for much higher intensity beam. The experimental results in CSRm show a good agreement with the analytical model in the IBS dominated regime. The simulation work offers us comparable results to those from the analytical model both in IBS dominated and space-charge dominated regimes.
NASA Astrophysics Data System (ADS)
Hong, Jangho; Kawashima, Ayato; Hamada, Noriaki
2017-06-01
In this study, we developed a facile fabrication method to access a highly reproducible plasmonic surface enhanced Raman scattering substrate via the immobilization of gold nanoparticles on an Ultrafiltration (UF) membrane using a suction technique. This was combined with a simple and rapid analyte concentration and detection method utilizing portable Raman spectroscopy. The minimum detectable concentrations for aqueous thiabendazole standard solution and thiabendazole in orange extract are 0.01 μg/mL and 0.125 μg/g, respectively. The partial least squares (PLS) regression plot shows a good linear relationship between 0.001 and 100 μg/mL of analyte, with a root mean square error of prediction (RMSEP) of 0.294 and a correlation coefficient (R2) of 0.976 for the thiabendazole standard solution. Meanwhile, the PLS plot also shows a good linear relationship between 0.0 and 2.5 μg/g of analyte, with an RMSEP value of 0.298 and an R2 value of 0.993 for the orange peel extract. In addition to the detection of other types of pesticides in agricultural products, this highly uniform plasmonic substrate has great potential for application in various environmentally-related areas.
A free-electron laser in a uniform magnetic field
NASA Technical Reports Server (NTRS)
Ride, S. K.; Colson, W. B.
1979-01-01
The study shows that a free-electron laser can operate in a uniform, longitudinal magnetic field. The fully relativistic Lorentz force equations are examined and solved order by order in a radiation field strength to obtain analytic expressions for the electron trajectory and energy as functions of initial electron position within a wavelength of light. Analytic expressions for the longitudinal and transverse bunching and for laser gain are found. The bunching of this laser process is compared to the bunching processes involved in (1) a Stanford free-electron laser and (2) a cyclotron maser. The results received can be useful in exploring light amplification in astrophysical magnetic fields, the magnetosphere, and in laboratory devices.
An optical fusion gate for W-states
NASA Astrophysics Data System (ADS)
Özdemir, Ş. K.; Matsunaga, E.; Tashima, T.; Yamamoto, T.; Koashi, M.; Imoto, N.
2011-10-01
We introduce a simple optical gate to fuse arbitrary-size polarization entangled W-states to prepare larger W-states. The gate requires a polarizing beam splitter (PBS), a half-wave plate (HWP) and two photon detectors. We study, numerically and analytically, the necessary resource consumption for preparing larger W-states by fusing smaller ones with the proposed fusion gate. We show analytically that resource requirement scales at most sub-exponentially with the increasing size of the state to be prepared. We numerically determine the resource cost for fusion without recycling where W-states of arbitrary size can be optimally prepared. Moreover, we introduce another strategy that is based on recycling and outperforms the optimal strategy for the non-recycling case.
NASA Astrophysics Data System (ADS)
Hobiny, Aatef D.; Abbas, Ibrahim A.
2018-01-01
The dual phase lag (DPL) heat transfer model is applied to study the photo-thermal interaction in an infinite semiconductor medium containing a spherical hole. The inner surface of the cavity was traction free and loaded thermally by pulse heat flux. By using the eigenvalue approach methodology and Laplace's transform, the physical variable solutions are obtained analytically. The numerical computations for the silicon-like semiconductor material are obtained. The comparison among the theories, i.e., dual phase lag (DPL), Lord and Shulman's (LS) and the classically coupled thermoelastic (CT) theory is presented graphically. The results further show that the analytical scheme can overcome mathematical problems by analyzing these problems.
da Rocha, Leticia; Sloane, Elliot; M Bassani, Jose
2005-01-01
This study describes a framework to support the choice of the maintenance service (in-house or third party contract) for each category of medical equipment based on: a) the real medical equipment maintenance management system currently used by the biomedical engineering group of the public health system of the Universidade Estadual de Campinas located in Brazil to control the medical equipment maintenance service, b) the Activity Based Costing (ABC) method, and c) the Analytic Hierarchy Process (AHP) method. Results show the cost and performance related to each type of maintenance service. Decision-makers can use these results to evaluate possible strategies for the categories of equipment.
Experimental and analytical study on fluid whirl and fluid whip modes
NASA Technical Reports Server (NTRS)
Muszynska, Agnes
1994-01-01
Fluid whirl and fluid whip are rotor self-excited, lateral vibrations which occur due to rotor interactions with the surrounding fluid. There exist various modes of fluid whirl and fluid whip. These modes are close to rotor modes corresponding to free vibrations (based on the linear model). Small differences are due to nonlinearities in the system. This paper presents experimental and analytical results on the lowest modes of fluid whirls and fluid whip. Examples of rotors supported in fluid lubricated bearings show the variations of rotor deflection amplitudes and phases in the whirl and whip modes with changes of rotative speeds and/or changes in lumped mass locations along the shaft.
Thrust reverser design studies for an over-the-wing STOL transport
NASA Technical Reports Server (NTRS)
Ammer, R. C.; Sowers, H. D.
1977-01-01
Aerodynamic and acoustics analytical studies were conducted to evaluate three thrust reverser designs for potential use on commercial over-the-wing STOL transports. The concepts were: (1) integral D nozzle/target reverser, (2) integral D nozzle/top arc cascade reverser, and (3) post exit target reverser integral with wing. Aerodynamic flowpaths and kinematic arrangements for each concept were established to provide a 50% thrust reversal capability. Analytical aircraft stopping distance/noise trade studies conducted concurrently with flow path design showed that these high efficiency reverser concepts are employed at substantially reduced power settings to meet noise goals of 100 PNdB on a 152.4 m sideline and still meet 609.6 m landing runway length requirements. From an overall installation standpoint, only the integral D nozzle/target reverser concept was found to penalize nacelle cruise performance; for this concept a larger nacelle diameter was required to match engine cycle effective area demand in reverse thrust.
Escuder-Gilabert, L; Ruiz-Roch, D; Villanueva-Camañas, R M; Medina-Hernández, M J; Sagrado, S
2004-03-12
In the present paper, the simultaneous quantification of two analytes showing strongly overlapped chromatographic peaks (alpha = 1.02), under the assumption that both available equipment and training of the laboratory staff are basic, is studied. A pharmaceutical preparation (Mutabase) containing two drugs of similar physicochemical properties (amitriptyline and perphenazine) is selected as case of study. The assays are carried out under realistic working conditions (i.e. routine testing laboratories). Uncertainty considerations are introduced in the study. A partial least squares model is directly applied to the chromatographic data (with no previous signal transformation) to perform quality control of the pharmaceutical formulation. Under the adequate protocol, the relative error in prediction of analytes is within the tolerances found in the pharmacopeia (10%). For spiked samples simulating formulation mistakes, the errors found have the same magnitude and sign to those provoked.
Practical deviations from Henry`s law for water/air partitioning of volatile organic compounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schabron, J.F.; Rovani, J.F. Jr.
A study was conducted to define parameters relating to the use of a down hole submersible photoionization detector (PID) probe to measure volatile organic compounds (VOCs) in an artificial headspace. The partitioning of toluene and trichloroethylene between water and air was studied as a function of analyte concentration and water temperature. The Henry`s law constant governing this partitioning represents an ideal condition at infinite dilution for a particular temperature. The results show that in practice. this partitioning is far from ideal. Conditions resulting in apparent, practical deviations from Henry`s law include temperature and VOC concentration. Thus, a single value ofmore » Henry`s law constant for a particular VOC such as toluene can provide only an approximation of concentration in the field. Detector response in saturated humidity environments as a function of water temperature and analyte concentration was studied also.« less
Application of Learning Analytics Using Clustering Data Mining for Students' Disposition Analysis
ERIC Educational Resources Information Center
Bharara, Sanyam; Sabitha, Sai; Bansal, Abhay
2018-01-01
Learning Analytics (LA) is an emerging field in which sophisticated analytic tools are used to improve learning and education. It draws from, and is closely tied to, a series of other fields of study like business intelligence, web analytics, academic analytics, educational data mining, and action analytics. The main objective of this research…
Visual analytics for aviation safety: A collaborative approach to sensemaking
NASA Astrophysics Data System (ADS)
Wade, Andrew
Visual analytics, the "science of analytical reasoning facilitated by interactive visual interfaces", is more than just visualization. Understanding the human reasoning process is essential for designing effective visualization tools and providing correct analyses. This thesis describes the evolution, application and evaluation of a new method for studying analytical reasoning that we have labeled paired analysis. Paired analysis combines subject matter experts (SMEs) and tool experts (TE) in an analytic dyad, here used to investigate aircraft maintenance and safety data. The method was developed and evaluated using interviews, pilot studies and analytic sessions during an internship at the Boeing Company. By enabling a collaborative approach to sensemaking that can be captured by researchers, paired analysis yielded rich data on human analytical reasoning that can be used to support analytic tool development and analyst training. Keywords: visual analytics, paired analysis, sensemaking, boeing, collaborative analysis.
ERIC Educational Resources Information Center
Brint, Steven; Cantwell, Allison M.; Saxena, Preeta
2012-01-01
Using data from the 2008 University of California Undergraduate Experience Survey, we show that study time and academic conscientiousness were lower among students in humanities and social science majors than among students in science and engineering majors. Analytical and critical thinking experiences were no more evident among humanities and…
Laughing and Smiling to Manage Trouble in French-Language Classroom Interaction
ERIC Educational Resources Information Center
Petitjean, Cécile; González-Martínez, Esther
2015-01-01
This article deals with communicative functions of laughter and smiling in the classroom studied using a conversation analytical approach. Analysing a corpus of video-recorded French first-language lessons, we show how students sequentially organise laughter and smiling, and use them to preempt, solve or assess a problematic action. We also focus…
ERIC Educational Resources Information Center
Herrmann, Daniel; Felfe, Jörg
2013-01-01
Transformational leadership is supposed to enhance employees' creativity. However, results of meta-analytic research on the relationships between transformational leadership and creativity fell short of expectations. In addition, the coefficients showed a huge variability. In this study, it was argued that relevant task and employee…
Evaluation of Lightning Induced Effects in a Graphite Composite Fairing Structure. Parts 1 and 2
NASA Technical Reports Server (NTRS)
Trout, Dawn H.; Stanley, James E.; Wahid, Parveen F.
2011-01-01
Defining the electromagnetic environment inside a graphite composite fairing due to lightning is of interest to spacecraft developers. This paper is the first in a two part series and studies the shielding effectiveness of a graphite composite model fairing using derived equivalent properties. A frequency domain Method of Moments (MoM) model is developed and comparisons are made with shielding test results obtained using a vehicle-like composite fairing. The comparison results show that the analytical models can adequately predict the test results. Both measured and model data indicate that graphite composite fairings provide significant attenuation to magnetic fields as frequency increases. Diffusion effects are also discussed. Part 2 examines the time domain based effects through the development of a loop based induced field testing and a Transmission-Line-Matrix (TLM) model is developed in the time domain to study how the composite fairing affects lightning induced magnetic fields. Comparisons are made with shielding test results obtained using a vehicle-like composite fairing in the time domain. The comparison results show that the analytical models can adequately predict the test and industry results.
Graphic report of the results from propensity score method analyses.
Shrier, Ian; Pang, Menglan; Platt, Robert W
2017-08-01
To increase transparency in studies reporting propensity scores by using graphical methods that clearly illustrate (1) the number of participant exclusions that occur as a consequence of the analytic strategy and (2) whether treatment effects are constant or heterogeneous across propensity scores. We applied graphical methods to a real-world pharmacoepidemiologic study that evaluated the effect of initiating statin medication on the 1-year all-cause mortality post-myocardial infarction. We propose graphical methods to show the consequences of trimming and matching on the exclusion of participants from the analysis. We also propose the use of meta-analytical forest plots to show the magnitude of effect heterogeneity. A density plot with vertical lines demonstrated the proportion of subjects excluded because of trimming. A frequency plot with horizontal lines demonstrated the proportion of subjects excluded because of matching. An augmented forest plot illustrates the amount of effect heterogeneity present in the data. Our proposed techniques present additional and useful information that helps readers understand the sample that is analyzed with propensity score methods and whether effect heterogeneity is present. Copyright © 2017 Elsevier Inc. All rights reserved.
Multiscale analysis of information dynamics for linear multivariate processes.
Faes, Luca; Montalto, Alessandro; Stramaglia, Sebastiano; Nollo, Giandomenico; Marinazzo, Daniele
2016-08-01
In the study of complex physical and physiological systems represented by multivariate time series, an issue of great interest is the description of the system dynamics over a range of different temporal scales. While information-theoretic approaches to the multiscale analysis of complex dynamics are being increasingly used, the theoretical properties of the applied measures are poorly understood. This study introduces for the first time a framework for the analytical computation of information dynamics for linear multivariate stochastic processes explored at different time scales. After showing that the multiscale processing of a vector autoregressive (VAR) process introduces a moving average (MA) component, we describe how to represent the resulting VARMA process using statespace (SS) models and how to exploit the SS model parameters to compute analytical measures of information storage and information transfer for the original and rescaled processes. The framework is then used to quantify multiscale information dynamics for simulated unidirectionally and bidirectionally coupled VAR processes, showing that rescaling may lead to insightful patterns of information storage and transfer but also to potentially misleading behaviors.
Leppanen, Jenni; Sedgewick, Felicity; Treasure, Janet; Tchanturia, Kate
2018-07-01
This meta-analytic review examines the theory of mind profiles in both patients with anorexia nervosa (AN) and autistic individuals. The studies examining theory of mind were divided into the following categories: emotional theory of mind, understanding simple social situations, understanding complex social interactions, and implicit social attribution. All included studies investigated differences between healthy control (HCs) individuals and people with AN or autistic people. Differences in theory of mind profile between people with AN and autistic people were explored by conducting moderator analyses. People with AN and autistic people showed a similar theory of mind profile, but autistic individuals showed greater difficulties, particularly in emotional theory of mind. Although both people with AN and autistic people have significant difficulties in all aspects of theory of mind relative to the HCs, some differences in the underlying profile may be present. However, due to relative paucity of theory of mind research among people with AN, further research is still needed before firm conclusion can be drawn. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Learning Dilemmas in Undergraduate Student Independent Essays
ERIC Educational Resources Information Center
Wendt, Maria; Åse, Cecilia
2015-01-01
Essay-writing is generally viewed as the primary learning activity to foster independence and analytical thinking. In this article, we show that independent research projects do not necessarily lead to critical thinking. University-level education on conducting independent projects can, in several respects, counteract enhanced analytical skills.…
The position of the analyst as expert: yesterday and today.
Fresenius, W
2000-11-01
The interrelation between law and analytical chemistry 150 years ago is outlined, showing that similar problems to today already existed at that time. Examples of present-day cases of judicial investigations are given and consequences for the duty of the analytical chemist are discussed.
CEDS Addresses: Rubric Elements
ERIC Educational Resources Information Center
US Department of Education, 2015
2015-01-01
Common Education Data Standards (CEDS) Version 4 introduced a common data vocabulary for defining rubrics in a data system. The CEDS elements support digital representations of both holistic and analytic rubrics. This document shares examples of holistic and analytic project rubrics, available CEDS Connections, and a logical model showing the…
Analytic solution and pulse area theorem for three-level atoms
NASA Astrophysics Data System (ADS)
Shchedrin, Gavriil; O'Brien, Chris; Rostovtsev, Yuri; Scully, Marlan O.
2015-12-01
We report an analytic solution for a three-level atom driven by arbitrary time-dependent electromagnetic pulses. In particular, we consider far-detuned driving pulses and show an excellent match between our analytic result and the numerical simulations. We use our solution to derive a pulse area theorem for three-level V and Λ systems without making the rotating wave approximation. Formulated as an energy conservation law, this pulse area theorem can be used to understand pulse propagation through three-level media.
Analytic convergence of harmonic metrics for parabolic Higgs bundles
NASA Astrophysics Data System (ADS)
Kim, Semin; Wilkin, Graeme
2018-04-01
In this paper we investigate the moduli space of parabolic Higgs bundles over a punctured Riemann surface with varying weights at the punctures. We show that the harmonic metric depends analytically on the weights and the stable Higgs bundle. This gives a Higgs bundle generalisation of a theorem of McOwen on the existence of hyperbolic cone metrics on a punctured surface within a given conformal class, and a generalisation of a theorem of Judge on the analytic parametrisation of these metrics.
NASA Technical Reports Server (NTRS)
Gottlieb, David; Shu, Chi-Wang; Solomonoff, Alex; Vandeven, Herve
1992-01-01
It is well known that the Fourier series of an analytic or periodic function, truncated after 2N+1 terms, converges exponentially with N, even in the maximum norm, although the function is still analytic. This is known as the Gibbs phenomenon. Here, we show that the first 2N+1 Fourier coefficients contain enough information about the function, so that an exponentially convergent approximation (in the maximum norm) can be constructed.
Ai, Yu; Wu, Yun; Wang, Fenrong; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua
2015-03-01
The objective of this study was to develop a sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous quantitation of three monoterpene glycosides (paeoniflorin, alibiflorin and oxypaeoniflorin) and four alkaloids (tetrahydropalmatine, corydaline, dehydrocorydaline and berberine), the main active ingredients of Radix Paeoniae Rubra extract (RPE) and Corydalis yanhusuo extract (CYE) in Huo Luo Xiao Ling Dan (HLXLD), and to compare the pharmacokinetics of these active ingredients in normal and arthritic rats orally administrated with HLXLD or RPE/CYE alone. The analytes and internal standard (IS) (geniposide) were separated on a XBridge C18 column (150 × 4.6 mm, 3.5 µm) using gradient elution with the mobile phase consisting of methanol and 0.01% formic acid in water at a flow rate of 0.6 ml/min. The detection of the analytes was performed on Acquity UPLC-MS/MS system with an electrospray ionization and multiple reaction monitoring mode via polarity switching between negative (for monoterpene glycosides) and positive (for alkaloids) ionization mode. The lower limits of quantification were 2.5, 1, 0.5, 0.2, 0.2, 0.02 and 0.01 ng/ml for paeoniflorin, alibiflorin, oxypaeoniflorin, tetrahydropalmatine, corydaline, dehydrocorydaline and berberine, respectively. Intra-day and inter-day precision and accuracy of analytes were well within acceptance criteria (15%). The mean extraction recoveries of analytes and IS from rat plasma were all more than 83.1%. The validated method has been successfully applied to determination of the analytes. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes between herbal formula and single herb group, normal and arthritic group. Copyright © 2015 John Wiley & Sons, Ltd.
Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms
NASA Astrophysics Data System (ADS)
Ozard, Siobhan R.
Electronic portal imagers designed and used to verify the positioning of a cancer patient undergoing radiation treatment can also be employed to measure the in vivo dose received by the patient. This thesis investigates the ratio of the dose from patient-scattered particles to the dose from primary (unscattered) photons at the imaging plane, called the scatter to primary dose ratio (SPR). The composition of the SPR according to the origin of scatter is analyzed more thoroughly than in previous studies. A new analytical method for calculating the SPR is developed and experimentally verified for heterogeneous phantoms. A novel technique that applies the analytical SPR method for in vivo dosimetry with a portal imager is evaluated. Monte Carlo simulation was used to determine the imager dose from patient-generated electrons and photons that scatter one or more times within the object. The database of SPRs reported from this investigation is new since the contribution from patient-generated electrons was neglected by previous Monte Carlo studies. The SPR from patient-generated electrons was found here to be as large as 0.03. The analytical SPR method relies on the established result that the scatter dose is uniform for an air gap between the patient and the imager that is greater than 50 cm. This method also applies the hypothesis that first-order Compton scatter only, is sufficient for scatter estimation. A comparison of analytical and measured SPRs for neck, thorax, and pelvis phantoms showed that the maximum difference was within +/-0.03, and the mean difference was less than +/-0.01 for most cases. This accuracy was comparable to similar analytical approaches that are limited to homogeneous phantoms. The analytical SPR method could replace lookup tables of measured scatter doses that can require significant time to measure. In vivo doses were calculated by combining our analytical SPR method and the convolution/superposition algorithm. Our calculated in vivo doses agreed within +/-3% with the doses measured in the phantom. The present in vivo method was faster compared to other techniques that use convolution/superposition. Our method is a feasible and satisfactory approach that contributes to on-line patient dose monitoring.
NASA Astrophysics Data System (ADS)
Allaerts, Dries; Meyers, Johan
2017-11-01
Wind farm design and control often relies on fast analytical wake models to predict turbine wake interactions and associated power losses. Essential input to these models are the inflow velocity and turbulent intensity at hub height, which come from prior measurement campaigns or wind-atlas data. Recent LES studies showed that in some situations large wind farms excite atmospheric gravity waves, which in turn affect the upstream wind conditions. In the current study, we develop a fast boundary-layer model that computes the excitation of gravity waves and the perturbation of the boundary-layer flow in response to an applied force. The core of the model is constituted by height-averaged, linearised Navier-Stokes equations for the inner and outer layer, and the effect of atmospheric gravity waves (excited by the boundary-layer displacement) is included via the pressure gradient. Coupling with analytical wake models allows us to study wind-farm wakes and upstream flow deceleration in various atmospheric conditions. Comparison with wind-farm LES results shows excellent agreement in terms of pressure and boundary-layer displacement levels. The authors acknowledge support from the European Research Council (FP7-Ideas, Grant No. 306471).
Dubský, Pavel; Müllerová, Ludmila; Dvořák, Martin; Gaš, Bohuslav
2015-03-06
The model of electromigration of a multivalent weak acidic/basic/amphoteric analyte that undergoes complexation with a mixture of selectors is introduced. The model provides an extension of the series of models starting with the single-selector model without dissociation by Wren and Rowe in 1992, continuing with the monovalent weak analyte/single-selector model by Rawjee, Williams and Vigh in 1993 and that by Lelièvre in 1994, and ending with the multi-selector overall model without dissociation developed by our group in 2008. The new multivalent analyte multi-selector model shows that the effective mobility of the analyte obeys the original Wren and Row's formula. The overall complexation constant, mobility of the free analyte and mobility of complex can be measured and used in a standard way. The mathematical expressions for the overall parameters are provided. We further demonstrate mathematically that the pH dependent parameters for weak analytes can be simply used as an input into the multi-selector overall model and, in reverse, the multi-selector overall parameters can serve as an input into the pH-dependent models for the weak analytes. These findings can greatly simplify the rationale method development in analytical electrophoresis, specifically enantioseparations. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Nicgorski, Dana; Avitabile, Peter
2010-07-01
Frequency-based substructuring is a very popular approach for the generation of system models from component measured data. Analytically the approach has been shown to produce accurate results. However, implementation with actual test data can cause difficulties and cause problems with the system response prediction. In order to produce good results, extreme care is needed in the measurement of the drive point and transfer impedances of the structure as well as observe all the conditions for a linear time invariant system. Several studies have been conducted to show the sensitivity of the technique to small variations that often occur during typical testing of structures. These variations have been observed in actual tested configurations and have been substantiated with analytical models to replicate the problems typically encountered. The use of analytically simulated issues helps to clearly see the effects of typical measurement difficulties often observed in test data. This paper presents some of these common problems observed and provides guidance and recommendations for data to be used for this modeling approach.
Hanaoka, Shigeyuki; Nomura, Koji; Kudo, Shinichi
2005-09-02
Knowledge of the exact nature of the constituents of abandoned chemical weapons (ACW) is a prerequisite for their orderly destruction. Here we report the development of analytical procedures to identify diphenylchloroarsine (DA/Clark I), diphenylcyanoarsine (DC/Clark II) and related substances employed in one of the munitions known as "Red canister". Both DA and DC are relatively unstable under conventional analytical procedures without thiol derivatization. Unfortunately however, thiol drivatization affords the same volatile organo-arsenic derivative from several different diphenylarsenic compounds, making it impossible to identify and quantify the original compounds. Further, diminishing the analytical interference caused by the celluloid powder used as a stacking material in the weapons, is also essential for accurate analysis. In this study, extraction and instrumental conditions have been evaluated and an optimal protocol was determined. The analysis of Red canister samples following this protocol showed that most of the DA and DC associated with pumice had degraded to bis(diphenylarsine)oxide (BDPAO), while those associated with celluloid were dominantly degraded to diphenylarsinic acid (DPAA).
Echeverría, S; Borrull, F; Fontanals, N; Pocurull, E
2013-11-15
A method for the quantitative determination of five iodinated X-ray contrast media (ICMs) in sewage was developed by solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry. A fused-core analytical column was successfully applied for the first time for the separation of ICMs. Oasis HLB was selected from the sorbents tested because of its higher recoveries. The optimized method allowed the determination of the ICMs at low ng/L levels in both influent and effluent sewage, with detection limits of 40 ng/L and 10 ng/L for most compounds in influent and effluent sewage, respectively. The five ICMs studied were determined in all samples analysed, with iopromide being the analyte found at the highest concentration (8.9 µg/L), while iopamidol was the analyte found at lowest concentration (1.3 µg/L) in influent sewage. Effluent sewage did not show a significant decrease in ICM concentrations. © 2013 Elsevier B.V. All rights reserved.
In-flight Evaluation of Aerodynamic Predictions of an Air-launched Space Booster
NASA Technical Reports Server (NTRS)
Curry, Robert E.; Mendenhall, Michael R.; Moulton, Bryan
1992-01-01
Several analytical aerodynamic design tools that were applied to the Pegasus (registered trademark) air-launched space booster were evaluated using flight measurements. The study was limited to existing codes and was conducted with limited computational resources. The flight instrumentation was constrained to have minimal impact on the primary Pegasus missions. Where appropriate, the flight measurements were compared with computational data. Aerodynamic performance and trim data from the first two flights were correlated with predictions. Local measurements in the wing and wing-body interference region were correlated with analytical data. This complex flow region includes the effect of aerothermal heating magnification caused by the presence of a corner vortex and interaction of the wing leading edge shock and fuselage boundary layer. The operation of the first two missions indicates that the aerodynamic design approach for Pegasus was adequate, and data show that acceptable margins were available. Additionally, the correlations provide insight into the capabilities of these analytical tools for more complex vehicles in which the design margins may be more stringent.
In-flight evaluation of aerodynamic predictions of an air-launched space booster
NASA Technical Reports Server (NTRS)
Curry, Robert E.; Mendenhall, Michael R.; Moulton, Bryan
1993-01-01
Several analytical aerodynamic design tools that were applied to the Pegasus air-launched space booster were evaluated using flight measurements. The study was limited to existing codes and was conducted with limited computational resources. The flight instrumentation was constrained to have minimal impact on the primary Pegasus missions. Where appropriate, the flight measurements were compared with computational data. Aerodynamic performance and trim data from the first two flights were correlated with predictions. Local measurements in the wing and wing-body interference region were correlated with analytical data. This complex flow region includes the effect of aerothermal heating magnification caused by the presence of a corner vortex and interaction of the wing leading edge shock and fuselage boundary layer. The operation of the first two missions indicates that the aerodynamic design approach for Pegasus was adequate, and data show that acceptable margins were available. Additionally, the correlations provide insight into the capabilities of these analytical tools for more complex vehicles in which design margins may be more stringent.
NASA Astrophysics Data System (ADS)
Sen, Osman Taha; Dreyer, Jason T.; Singh, Rajendra
2014-12-01
In this article, a feasibility study of controlling the low frequency torque response of a disc brake system with modulated actuation pressure (in the open loop mode) is conducted. First, a quasi-linear model of the torsional system is introduced, and analytical solutions are proposed to incorporate the modulation effect. Tractable expressions for three different modulation schemes are obtained, and conditions that would lead to a reduction in the oscillatory amplitudes are identified. Second, these conditions are evaluated with a numerical model of the torsional system with clearance nonlinearity, and analytical solutions are verified in terms of the trends observed. Finally, a laboratory experiment with a solenoid valve is built to modulate actuation pressure with a constant duty cycle, and time-frequency domain data are acquired. Measurements are utilized to assess analytical observations, and all methods show that the speed-dependent brake torque amplitudes can be altered with an appropriate modulation of actuation pressure.
NASA Astrophysics Data System (ADS)
Akai, Takashi; Bijeljic, Branko; Blunt, Martin J.
2018-06-01
In the color gradient lattice Boltzmann model (CG-LBM), a fictitious-density wetting boundary condition has been widely used because of its ease of implementation. However, as we show, this may lead to inaccurate results in some cases. In this paper, a new scheme for the wetting boundary condition is proposed which can handle complicated 3D geometries. The validity of our method for static problems is demonstrated by comparing the simulated results to analytical solutions in 2D and 3D geometries with curved boundaries. Then, capillary rise simulations are performed to study dynamic problems where the three-phase contact line moves. The results are compared to experimental results in the literature (Heshmati and Piri, 2014). If a constant contact angle is assumed, the simulations agree with the analytical solution based on the Lucas-Washburn equation. However, to match the experiments, we need to implement a dynamic contact angle that varies with the flow rate.
Yan, Liang; Peng, Juanjuan; Jiao, Zongxia; Chen, Chin-Yin; Chen, I-Ming
2014-10-01
This paper proposes a novel permanent magnet linear motor possessing two movers and one stator. The two movers are isolated and can interact with the stator poles to generate independent forces and motions. Compared with conventional multiple motor driving system, it helps to increase the system compactness, and thus improve the power density and working efficiency. The magnetic field distribution is obtained by using equivalent magnetic circuit method. Following that, the formulation of force output considering armature reaction is carried out. Then inductances are analyzed with finite element method to investigate the relationships of the two movers. It is found that the mutual-inductances are nearly equal to zero, and thus the interaction between the two movers is negligible. A research prototype of the linear motor and a measurement apparatus on thrust force have been developed. Both numerical computation and experiment measurement are conducted to validate the analytical model of thrust force. Comparison shows that the analytical model matches the numerical and experimental results well.
NASA Technical Reports Server (NTRS)
Mukhopadhyay, A. K.
1975-01-01
Linear frequency domain methods are inadequate in analyzing the 1975 Viking Orbiter (VO75) digital tape recorder servo due to dominant nonlinear effects such as servo signal limiting, unidirectional servo control, and static/dynamic Coulomb friction. The frequency loop (speed control) servo of the VO75 tape recorder is used to illustrate the analytical tools and methodology of system redundancy elimination and high order transfer function verification. The paper compares time-domain performance parameters derived from a series of nonlinear time responses with the available experimental data in order to select the best possible analytical transfer function representation of the tape transport (mechanical segment of the tape recorder) from several possible candidates. The study also shows how an analytical time-response simulation taking into account most system nonlinearities can pinpoint system redundancy and overdesign stemming from a strictly empirical design approach. System order reduction is achieved through truncation of individual transfer functions and elimination of redundant blocks.
Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Rezaee Aghdam, Samaneh; Nouri, Nina; Bamorrowat, Mahdi
2016-12-01
In the present study, an elevated temperature, dispersive, liquid-liquid microextraction/gas chromatography-flame ionization detection was investigated for the determination, pre-concentration, and extraction of six organophosphorus pesticides (malathion, phosalone, dichlorvos, diazinon, profenofos, and chlorpyrifos) residues in fruit juice and aqueous samples. A mixture of 1,2-dibromoethane (extraction solvent) and dimethyl sulfoxide (disperser solvent) was injected rapidly into the sample solution heated at an elevated temperature. Analytical parameters, including enrichment factors (1600-2075), linearity (r>0.994), limits of detection (0.82-2.72ngmL(-1)) and quantification (2.60-7.36ngmL(-1)), relative standard deviations (<7%) and extraction recoveries (64-83%), showed the high efficiency of the method developed for analysis of the target analytes. The proposed procedure was used effectively to analyse selected analytes in river water and fruit juice, and diazinon was found at ngmL(-1) concentrations in apple juice. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reddy, Bhargava K; Delen, Dursun; Agrawal, Rupesh K
2018-01-01
Crohn's disease is among the chronic inflammatory bowel diseases that impact the gastrointestinal tract. Understanding and predicting the severity of inflammation in real-time settings is critical to disease management. Extant literature has primarily focused on studies that are conducted in clinical trial settings to investigate the impact of a drug treatment on the remission status of the disease. This research proposes an analytics methodology where three different types of prediction models are developed to predict and to explain the severity of inflammation in patients diagnosed with Crohn's disease. The results show that machine-learning-based analytic methods such as gradient boosting machines can predict the inflammation severity with a very high accuracy (area under the curve = 92.82%), followed by regularized regression and logistic regression. According to the findings, a combination of baseline laboratory parameters, patient demographic characteristics, and disease location are among the strongest predictors of inflammation severity in Crohn's disease patients.
Developing Guidelines for Assessing Visual Analytics Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholtz, Jean
2011-07-01
In this paper, we develop guidelines for evaluating visual analytic environments based on a synthesis of reviews for the entries to the 2009 Visual Analytics Science and Technology (VAST) Symposium Challenge and from a user study with professional intelligence analysts. By analyzing the 2009 VAST Challenge reviews we gained a better understanding of what is important to our reviewers, both visualization researchers and professional analysts. We also report on a small user study with professional analysts to determine the important factors that they use in evaluating visual analysis systems. We then looked at guidelines developed by researchers in various domainsmore » and synthesized these into an initial set for use by others in the community. In a second part of the user study, we looked at guidelines for a new aspect of visual analytic systems – the generation of reports. Future visual analytic systems have been challenged to help analysts generate their reports. In our study we worked with analysts to understand the criteria they used to evaluate the quality of analytic reports. We propose that this knowledge will be useful as researchers look at systems to automate some of the report generation.1 Based on these efforts, we produced some initial guidelines for evaluating visual analytic environment and for evaluation of analytic reports. It is important to understand that these guidelines are initial drafts and are limited in scope because of the type of tasks for which the visual analytic systems used in the studies in this paper were designed. More research and refinement is needed by the Visual Analytics Community to provide additional evaluation guidelines for different types of visual analytic environments.« less
Vieux, Florent; Dubois, Christophe; Allegre, Laëtitia; Mandon, Lionel; Ciantar, Laurent; Darmon, Nicole
2013-01-01
To assess the impact on food-related cost of meals to fulfill the new compulsory dietary standards for primary schools in France. A descriptive study assessed the relationship between the level of compliance with the standards of observed school meals and their food-related cost. An analytical study assessed the cost of series of meals published in professional journals, and complying or not with new dietary standards. The costs were based on prices actually paid for food used to prepare school meals. Food-related cost of meals. Parametric and nonparametric tests from a total of 42 and 120 series of 20 meals in the analytical and descriptive studies, respectively. The descriptive study indicated that meeting the standards was not related to cost. The analytical study showed that fulfilling the frequency guidelines increased the cost, whereas fulfilling the portion sizes criteria decreased it. Series of meals fully respecting the standards (ie, frequency and portion sizes) cost significantly less (-0.10 €/meal) than series not fulfilling them, because the standards recommend smaller portion sizes. Introducing portion sizes rules in dietary standards for school catering may help increase dietary quality without increasing the food cost of meals. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Active Control of Inlet Noise on the JT15D Turbofan Engine
NASA Technical Reports Server (NTRS)
Smith, Jerome P.; Hutcheson, Florence V.; Burdisso, Ricardo A.; Fuller, Chris R.
1999-01-01
This report presents the key results obtained by the Vibration and Acoustics Laboratories at Virginia Tech over the year from November 1997 to December 1998 on the Active Noise Control of Turbofan Engines research project funded by NASA Langley Research Center. The concept of implementing active noise control techniques with fuselage-mounted error sensors is investigated both analytically and experimentally. The analytical part of the project involves the continued development of an advanced modeling technique to provide prediction and design guidelines for application of active noise control techniques to large, realistic high bypass engines of the type on which active control methods are expected to be applied. Results from the advanced analytical model are presented that show the effectiveness of the control strategies, and the analytical results presented for fuselage error sensors show good agreement with the experimentally observed results and provide additional insight into the control phenomena. Additional analytical results are presented for active noise control used in conjunction with a wavenumber sensing technique. The experimental work is carried out on a running JT15D turbofan jet engine in a test stand at Virginia Tech. The control strategy used in these tests was the feedforward Filtered-X LMS algorithm. The control inputs were supplied by single and multiple circumferential arrays of acoustic sources equipped with neodymium iron cobalt magnets mounted upstream of the fan. The reference signal was obtained from an inlet mounted eddy current probe. The error signals were obtained from a number of pressure transducers flush-mounted in a simulated fuselage section mounted in the engine test cell. The active control methods are investigated when implemented with the control sources embedded within the acoustically absorptive material on a passively-lined inlet. The experimental results show that the combination of active control techniques with fuselage-mounted error sensors and passive control techniques is an effective means of reducing radiated noise from turbofan engines. Strategic selection of the location of the error transducers is shown to be effective for reducing the radiation towards particular directions in the farfield. An analytical model is used to predict the behavior of the control system and to guide the experimental design configurations, and the analytical results presented show good agreement with the experimentally observed results.
Qian Cutrone, Jingfang Jenny; Huang, Xiaohua Stella; Kozlowski, Edward S; Bao, Ye; Wang, Yingzi; Poronsky, Christopher S; Drexler, Dieter M; Tymiak, Adrienne A
2017-05-10
Synthetic macrocyclic peptides with natural and unnatural amino acids have gained considerable attention from a number of pharmaceutical/biopharmaceutical companies in recent years as a promising approach to drug discovery, particularly for targets involving protein-protein or protein-peptide interactions. Analytical scientists charged with characterizing these leads face multiple challenges including dealing with a class of complex molecules with the potential for multiple isomers and variable charge states and no established standards for acceptable analytical characterization of materials used in drug discovery. In addition, due to the lack of intermediate purification during solid phase peptide synthesis, the final products usually contain a complex profile of impurities. In this paper, practical analytical strategies and methodologies were developed to address these challenges, including a tiered approach to assessing the purity of macrocyclic peptides at different stages of drug discovery. Our results also showed that successful progression and characterization of a new drug discovery modality benefited from active analytical engagement, focusing on fit-for-purpose analyses and leveraging a broad palette of analytical technologies and resources. Copyright © 2017. Published by Elsevier B.V.
Complexometric Determination of Mercury Based on a Selective Masking Reaction
ERIC Educational Resources Information Center
Romero, Mercedes; Guidi, Veronica; Ibarrolaza, Agustin; Castells, Cecilia
2009-01-01
In the first analytical chemistry course, students are introduced to the concepts of equilibrium in water solutions and classical (non-instrumental) analytical methods. Our teaching experience shows that "real samples" stimulate students' enthusiasm for the laboratory work. From this diagnostic, we implemented an optional activity at the end of…
Teaching Critical & Analytical Thinking in High School Biology?
ERIC Educational Resources Information Center
McDonald, Gaby
2012-01-01
How can critical and analytical thinking be improved so that they mimic real-life research and prepare students for university courses? The data sets obtained in students' experiments were used to encourage students to evaluate results, experiments, and published information critically. Examples show that students can learn to compare and defend…
NASA Astrophysics Data System (ADS)
Sanskrityayn, Abhishek; Suk, Heejun; Kumar, Naveen
2017-04-01
In this study, analytical solutions of one-dimensional pollutant transport originating from instantaneous and continuous point sources were developed in groundwater and riverine flow using both Green's Function Method (GFM) and pertinent coordinate transformation method. Dispersion coefficient and flow velocity are considered spatially and temporally dependent. The spatial dependence of the velocity is linear, non-homogeneous and that of dispersion coefficient is square of that of velocity, while the temporal dependence is considered linear, exponentially and asymptotically decelerating and accelerating. Our proposed analytical solutions are derived for three different situations depending on variations of dispersion coefficient and velocity, respectively which can represent real physical processes occurring in groundwater and riverine systems. First case refers to steady solute transport situation in steady flow in which dispersion coefficient and velocity are only spatially dependent. The second case represents transient solute transport in steady flow in which dispersion coefficient is spatially and temporally dependent while the velocity is spatially dependent. Finally, the third case indicates transient solute transport in unsteady flow in which both dispersion coefficient and velocity are spatially and temporally dependent. The present paper demonstrates the concentration distribution behavior from a point source in realistically occurring flow domains of hydrological systems including groundwater and riverine water in which the dispersivity of pollutant's mass is affected by heterogeneity of the medium as well as by other factors like velocity fluctuations, while velocity is influenced by water table slope and recharge rate. Such capabilities give the proposed method's superiority about application of various hydrological problems to be solved over other previously existing analytical solutions. Especially, to author's knowledge, any other solution doesn't exist for both spatially and temporally variations of dispersion coefficient and velocity. In this study, the existing analytical solutions from previous widely known studies are used for comparison as validation tools to verify the proposed analytical solution as well as the numerical code of the Two-Dimensional Subsurface Flow, Fate and Transport of Microbes and Chemicals (2DFATMIC) code and the developed 1D finite difference code (FDM). All such solutions show perfect match with the respective proposed solutions.
Nekhay, Olexandr; Arriaza, Manuel; Boerboom, Luc
2009-07-01
The study presents an approach that combined objective information such as sampling or experimental data with subjective information such as expert opinions. This combined approach was based on the Analytic Network Process method. It was applied to evaluate soil erosion risk and overcomes one of the drawbacks of USLE/RUSLE soil erosion models, namely that they do not consider interactions among soil erosion factors. Another advantage of this method is that it can be used if there are insufficient experimental data. The lack of experimental data can be compensated for through the use of expert evaluations. As an example of the proposed approach, the risk of soil erosion was evaluated in olive groves in Southern Spain, showing the potential of the ANP method for modelling a complex physical process like soil erosion.
An analytical study of physical models with inherited temporal and spatial memory
NASA Astrophysics Data System (ADS)
Jaradat, Imad; Alquran, Marwan; Al-Khaled, Kamel
2018-04-01
Du et al. (Sci. Reb. 3, 3431 (2013)) demonstrated that the fractional derivative order can be physically interpreted as a memory index by fitting the test data of memory phenomena. The aim of this work is to study analytically the joint effect of the memory index on time and space coordinates simultaneously. For this purpose, we introduce a novel bivariate fractional power series expansion that is accompanied by twofold fractional derivatives ordering α, β\\in(0,1]. Further, some convergence criteria concerning our expansion are presented and an analog of the well-known bivariate Taylor's formula in the sense of mixed fractional derivatives is obtained. Finally, in order to show the functionality and efficiency of this expansion, we employ the corresponding Taylor's series method to obtain closed-form solutions of various physical models with inherited time and space memory.
Speciation and Characterization of E-Waste, Using Analytical Techniques
NASA Astrophysics Data System (ADS)
López, C. Cortés; Cruz, V. E. Reyes; Rodríguez, M. A. Veloz; Ávila, J. Hernández; Badillo, J. Flores; Murcia, J. A. Cobos
Electronic waste (e-waste), have a high potential as a source of precious metals, since they can contain metals like silver, gold, platinum, copper, zinc, nickel, tin and others. In this paper some e-waste were characterized using several analytical techniques as Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and inductively coupled plasma (ICP) in addition to the thermodynamic study by Pourbaix diagrams of silver (Ag), gold (Au), platinum (Pt), copper (Cu), nickel (Ni), tin (Sn) and zinc (Zn); considering an average low concentration of HNO3 (10% v/v). With results of the characterization was determined that the e-waste is an ideal source for the recovery of valuable metals. Similarly, the thermodynamic studies showed that it is possible to obtain all metallic species except Pt, in a potential window of 1.45V to 2.0V vs SCE.
Forgetfulness can help you win games.
Burridge, James; Gao, Yu; Mao, Yong
2015-09-01
We present a simple game model where agents with different memory lengths compete for finite resources. We show by simulation and analytically that an instability exists at a critical memory length, and as a result, different memory lengths can compete and coexist in a dynamical equilibrium. Our analytical formulation makes a connection to statistical urn models, and we show that temperature is mirrored by the agent's memory. Our simple model of memory may be incorporated into other game models with implications that we briefly discuss.
Fractional Talbot field and of finite gratings: compact analytical formulation.
Arrizón, V; Rojo-Velázquez, G
2001-06-01
We present a compact analytical formulation for the fractional Talbot effect at the paraxial domain of a finite grating. Our results show that laterally shifted distorted images of the grating basic cell form the Fresnel field at a fractional Talbot plane of the grating. Our formulas give the positions of those images and show that they are given by the convolution of the nondistorted cells (modulated by a quadratic phase factor) with the Fourier transform of the finite-grating pupil.
Peyron, Pierre-Antoine; Baccino, Éric; Nagot, Nicolas; Lehmann, Sylvain; Delaby, Constance
2017-02-01
Determination of skin wound vitality is an important issue in forensic practice. No reliable biomarker currently exists. Quantification of inflammatory cytokines in injured skin with MSD ® technology is an innovative and promising approach. This preliminary study aims to develop a protocol for the preparation and the analysis of skin samples. Samples from ante mortem wounds, post mortem wounds, and intact skin ("control samples") were taken from corpses at the autopsy. After an optimization of the pre-analytical protocol had been performed in terms of skin homogeneisation and proteic extraction, the concentration of TNF-α was measured in each sample with the MSD ® approach. Then five other cytokines of interest (IL-1β, IL-6, IL-10, IL-12p70 and IFN-γ) were simultaneously quantified with a MSD ® multiplex assay. The optimal pre-analytical conditions consist in a proteic extraction from a 6 mm diameter skin sample, in a PBS buffer with triton 0,05%. Our results show the linearity and the reproductibility of the TNF-α quantification with MSD ® , and an inter- and intra-individual variability of the concentrations of proteins. The MSD ® multiplex assay is likely to detect differential skin concentrations for each cytokine of interest. This preliminary study was used to develop and optimize the pre-analytical and analytical conditions of the MSD ® method using injured and healthy skin samples, for the purpose of looking for and identifying the cytokine, or the set of cytokines, that may be biomarkers of skin wound vitality.
NASA Astrophysics Data System (ADS)
Nakada, Tomohiro; Takadama, Keiki; Watanabe, Shigeyoshi
This paper proposes the classification method using Bayesian analytical method to classify the time series data in the international emissions trading market depend on the agent-based simulation and compares the case with Discrete Fourier transform analytical method. The purpose demonstrates the analytical methods mapping time series data such as market price. These analytical methods have revealed the following results: (1) the classification methods indicate the distance of mapping from the time series data, it is easier the understanding and inference than time series data; (2) these methods can analyze the uncertain time series data using the distance via agent-based simulation including stationary process and non-stationary process; and (3) Bayesian analytical method can show the 1% difference description of the emission reduction targets of agent.
MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.
Horowitz, Gary L; Zaman, Zahur; Blanckaert, Norbert J C; Chan, Daniel W; Dubois, Jeffrey A; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W; Nilsen, Olaug L; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang
2005-01-01
MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.
MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory
Zaman, Zahur; Blanckaert, Norbert J. C.; Chan, Daniel W.; Dubois, Jeffrey A.; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W.; Nilsen, Olaug L.; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L.; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang
2005-01-01
MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality. PMID:18924721
An overview on forensic analysis devoted to analytical chemists.
Castillo-Peinado, L S; Luque de Castro, M D
2017-05-15
The present article has as main aim to show analytical chemists interested in forensic analysis the world they will face if decision in favor of being a forensic analytical chemist is adopted. With this purpose, the most outstanding aspects of forensic analysis in dealing with sampling (involving both bodily and no bodily samples), sample preparation, and analytical equipment used in detection, identification and quantitation of key sample components are critically discussed. The role of the great omics in forensic analysis, and the growing role of the youngest of the great omics -metabolomics- are also discussed. The foreseeable role of integrative omics is also outlined. Copyright © 2017 Elsevier B.V. All rights reserved.
Solutions of conformal Israel-Stewart relativistic viscous fluid dynamics
NASA Astrophysics Data System (ADS)
Marrochio, Hugo; Noronha, Jorge; Denicol, Gabriel S.; Luzum, Matthew; Jeon, Sangyong; Gale, Charles
2015-01-01
We use symmetry arguments developed by Gubser to construct the first radially expanding explicit solutions of the Israel-Stewart formulation of hydrodynamics. Along with a general semi-analytical solution, an exact analytical solution is given which is valid in the cold plasma limit where viscous effects from shear viscosity and the relaxation time coefficient are important. The radially expanding solutions presented in this paper can be used as nontrivial checks of numerical algorithms employed in hydrodynamic simulations of the quark-gluon plasma formed in ultrarelativistic heavy ion collisions. We show this explicitly by comparing such analytic and semi-analytic solutions with the corresponding numerical solutions obtained using the music viscous hydrodynamics simulation code.
Estimation of the uncertainty of analyte concentration from the measurement uncertainty.
Brown, Simon; Cooke, Delwyn G; Blackwell, Leonard F
2015-09-01
Ligand-binding assays, such as immunoassays, are usually analysed using standard curves based on the four-parameter and five-parameter logistic models. An estimate of the uncertainty of an analyte concentration obtained from such curves is needed for confidence intervals or precision profiles. Using a numerical simulation approach, it is shown that the uncertainty of the analyte concentration estimate becomes significant at the extremes of the concentration range and that this is affected significantly by the steepness of the standard curve. We also provide expressions for the coefficient of variation of the analyte concentration estimate from which confidence intervals and the precision profile can be obtained. Using three examples, we show that the expressions perform well.
ERIC Educational Resources Information Center
Sawaki, Yasuyo
2007-01-01
This is a construct validation study of a second language speaking assessment that reported a language profile based on analytic rating scales and a composite score. The study addressed three key issues: score dependability, convergent/discriminant validity of analytic rating scales and the weighting of analytic ratings in the composite score.…
O'Neal, Wanda K; Anderson, Wayne; Basta, Patricia V; Carretta, Elizabeth E; Doerschuk, Claire M; Barr, R Graham; Bleecker, Eugene R; Christenson, Stephanie A; Curtis, Jeffrey L; Han, Meilan K; Hansel, Nadia N; Kanner, Richard E; Kleerup, Eric C; Martinez, Fernando J; Miller, Bruce E; Peters, Stephen P; Rennard, Stephen I; Scholand, Mary Beth; Tal-Singer, Ruth; Woodruff, Prescott G; Couper, David J; Davis, Sonia M
2014-01-08
As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100). 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers.
2014-01-01
Background As a part of the longitudinal Chronic Obstructive Pulmonary Disease (COPD) study, Subpopulations and Intermediate Outcome Measures in COPD study (SPIROMICS), blood samples are being collected from 3200 subjects with the goal of identifying blood biomarkers for sub-phenotyping patients and predicting disease progression. To determine the most reliable sample type for measuring specific blood analytes in the cohort, a pilot study was performed from a subset of 24 subjects comparing serum, Ethylenediaminetetraacetic acid (EDTA) plasma, and EDTA plasma with proteinase inhibitors (P100™). Methods 105 analytes, chosen for potential relevance to COPD, arranged in 12 multiplex and one simplex platform (Myriad-RBM) were evaluated in duplicate from the three sample types from 24 subjects. The reliability coefficient and the coefficient of variation (CV) were calculated. The performance of each analyte and mean analyte levels were evaluated across sample types. Results 20% of analytes were not consistently detectable in any sample type. Higher reliability and/or smaller CV were determined for 12 analytes in EDTA plasma compared to serum, and for 11 analytes in serum compared to EDTA plasma. While reliability measures were similar for EDTA plasma and P100 plasma for a majority of analytes, CV was modestly increased in P100 plasma for eight analytes. Each analyte within a multiplex produced independent measurement characteristics, complicating selection of sample type for individual multiplexes. Conclusions There were notable detectability and measurability differences between serum and plasma. Multiplexing may not be ideal if large reliability differences exist across analytes measured within the multiplex, especially if values differ based on sample type. For some analytes, the large CV should be considered during experimental design, and the use of duplicate and/or triplicate samples may be necessary. These results should prove useful for studies evaluating selection of samples for evaluation of potential blood biomarkers. PMID:24397870
Bruno, C; Patin, F; Bocca, C; Nadal-Desbarats, L; Bonnier, F; Reynier, P; Emond, P; Vourc'h, P; Joseph-Delafont, K; Corcia, P; Andres, C R; Blasco, H
2018-01-30
Metabolomics is an emerging science based on diverse high throughput methods that are rapidly evolving to improve metabolic coverage of biological fluids and tissues. Technical progress has led researchers to combine several analytical methods without reporting the impact on metabolic coverage of such a strategy. The objective of our study was to develop and validate several analytical techniques (mass spectrometry coupled to gas or liquid chromatography and nuclear magnetic resonance) for the metabolomic analysis of small muscle samples and evaluate the impact of combining methods for more exhaustive metabolite covering. We evaluated the muscle metabolome from the same pool of mouse muscle samples after 2 metabolite extraction protocols. Four analytical methods were used: targeted flow injection analysis coupled with mass spectrometry (FIA-MS/MS), gas chromatography coupled with mass spectrometry (GC-MS), liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS), and nuclear magnetic resonance (NMR) analysis. We evaluated the global variability of each compound i.e., analytical (from quality controls) and extraction variability (from muscle extracts). We determined the best extraction method and we reported the common and distinct metabolites identified based on the number and identity of the compounds detected with low analytical variability (variation coefficient<30%) for each method. Finally, we assessed the coverage of muscle metabolic pathways obtained. Methanol/chloroform/water and water/methanol were the best extraction solvent for muscle metabolome analysis by NMR and MS, respectively. We identified 38 metabolites by nuclear magnetic resonance, 37 by FIA-MS/MS, 18 by GC-MS, and 80 by LC-HRMS. The combination led us to identify a total of 132 metabolites with low variability partitioned into 58 metabolic pathways, such as amino acid, nitrogen, purine, and pyrimidine metabolism, and the citric acid cycle. This combination also showed that the contribution of GC-MS was low when used in combination with other mass spectrometry methods and nuclear magnetic resonance to explore muscle samples. This study reports the validation of several analytical methods, based on nuclear magnetic resonance and several mass spectrometry methods, to explore the muscle metabolome from a small amount of tissue, comparable to that obtained during a clinical trial. The combination of several techniques may be relevant for the exploration of muscle metabolism, with acceptable analytical variability and overlap between methods However, the difficult and time-consuming data pre-processing, processing, and statistical analysis steps do not justify systematically combining analytical methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K
2017-04-01
The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Guise, Andy; Horyniak, Danielle; Melo, Jason; McNeil, Ryan; Werb, Dan
2017-12-01
Understanding the experience of initiating injection drug use and its social contexts is crucial to inform efforts to prevent transitions into this mode of drug consumption and support harm reduction. We reviewed and synthesized existing qualitative scientific literature systematically to identify the socio-structural contexts for, and experiences of, the initiation of injection drug use. We searched six databases (Medline, Embase, PsychINFO, CINAHL, IBSS and SSCI) systematically, along with a manual search, including key journals and subject experts. Peer-reviewed studies were included if they qualitatively explored experiences of or socio-structural contexts for injection drug use initiation. A thematic synthesis approach was used to identify descriptive and analytical themes throughout studies. From 1731 initial results, 41 studies reporting data from 1996 participants were included. We developed eight descriptive themes and two analytical (higher-order) themes. The first analytical theme focused on injecting initiation resulting from a social process enabled and constrained by socio-structural factors: social networks and individual interactions, socialization into drug-using identities and choices enabled and constrained by social context all combine to produce processes of injection initiation. The second analytical theme addressed pathways that explore varying meanings attached to injection initiation and how they link to social context: seeking pleasure, responses to increasing tolerance to drugs, securing belonging and identity and coping with pain and trauma. Qualitative research shows that injection drug use initiation has varying and distinct meanings for individuals involved and is a dynamic process shaped by social and structural factors. Interventions should therefore respond to the socio-structural influences on injecting drug use initiation by seeking to modify the contexts for initiation, rather than solely prioritizing the reduction of individual harms through behavior change. © 2017 Society for the Study of Addiction.
Fundamental studies of MALDI with an orthogonal TOF mass spectrometer
NASA Astrophysics Data System (ADS)
Qiao, Hui
The interaction between the matrix and analyte molecules are studied with a high resolution MALDI imaging technique in an orthogonal-injection time of flight (TOF) mass spectrometer. The analyte incorporation and distribution patterns have been clearly demonstrated. Purified protein analytes were found to be homogeneously incorporated in large single crystals of DHB and sinapinic acid matrices, with no evidence for preferred crystal faces. Segregation of some species was observed and appeared to correlate with analyte hydrophobicity, and to a lesser extent analyte mass or mobility. Similar segregation phenomena were observed with confocal laser scanning microscopy of the same analytes labeled with fluorescent dyes in 2,5-DHB single crystals. The above investigations may shed some light on optimizing sample preparation with different matrices. The influence of incident laser parameters on sensitivity in MALDI has been investigated using orthogonal-injection TOF instruments. A qualitative comparison was first made between the beam profiles obtained with a N 2 laser and a Nd:YAG laser using 2-m long optical fibers. The N 2 laser gives better sensitivity, consistent with a more uniform fluence distribution and therefore better coverage of the N2 laser profile. Most of the difference disappears when a 30-m long fiber is used or when the fibers are twisted during irradiation to smooth out the fluence distribution. In more systematic measurements, the total integrated ion yield from a single spot (a measure of sensitivity) was found to increase rapidly with fluence to a maximum, and then saturate or decrease slightly. Thus, the optimum sensitivity is achieved at high fluence. For a fluence near threshold, the integrated yield has a steep (cubic) dependence on the spot size, but the yield saturates at higher fluence for smaller spots. The area dependence is much weaker (close to linear) for fluence values above saturation, with the result that the highest integrated yields per unit area are obtained with the smallest spot sizes. The results have particular relevance for imaging MALDI, where sensitivity and spatial resolution are important figures of merit. Finally the detection properties of the MCP detector were studied with a hybrid MCP and CuBe venetian blind converter detector. The measurements show that the detection efficiency of the MCP drops with the increasing of ion mass and the decreasing of the ion energy. For transferrin (79,500 Da), the relative detection efficiency of the MCP is about 40% at 10.6 keV and it decreases to about 5% at 4.6 keV. The secondary electron emission coefficient of the MCP shows a linear dependence on mass and a power law dependence on velocity (˜3.2). No clear velocity threshold is observed for secondary electron emission.
EPDM Based Double Slope Triangular Enclosure Solar Collector: A Novel Approach
Qureshi, Shafiq R.; Khan, Waqar A.
2014-01-01
Solar heating is one of the important utilities of solar energy both in domestic and industrial sectors. Evacuated tube heaters are a commonly used technology for domestic water heating. However, increasing cost of copper and nickel has resulted in huge initial cost for these types of heaters. Utilizing solar energy more economically for domestic use requires new concept which has low initial and operating costs together with ease of maintainability. As domestic heating requires only nominal heating temperature to the range of 60–90°C, therefore replacing nickel coated copper pipes with any cheap alternate can drastically reduce the cost of solar heater. We have proposed a new concept which utilizes double slope triangular chamber with EPDM based synthetic rubber pipes. This has reduced the initial and operating costs substantially. A detailed analytical study was carried out to design a novel solar heater. On the basis of analytical design, a prototype was manufactured. Results obtained from the experiments were found to be in good agreement with the analytical study. A maximum error of 10% was recorded at noon. However, results show that error is less than 5% in early and late hours. PMID:24688407
EPDM based double slope triangular enclosure solar collector: a novel approach.
Qureshi, Shafiq R; Khan, Waqar A; Sarwar, Waqas
2014-01-01
Solar heating is one of the important utilities of solar energy both in domestic and industrial sectors. Evacuated tube heaters are a commonly used technology for domestic water heating. However, increasing cost of copper and nickel has resulted in huge initial cost for these types of heaters. Utilizing solar energy more economically for domestic use requires new concept which has low initial and operating costs together with ease of maintainability. As domestic heating requires only nominal heating temperature to the range of 60-90 °C, therefore replacing nickel coated copper pipes with any cheap alternate can drastically reduce the cost of solar heater. We have proposed a new concept which utilizes double slope triangular chamber with EPDM based synthetic rubber pipes. This has reduced the initial and operating costs substantially. A detailed analytical study was carried out to design a novel solar heater. On the basis of analytical design, a prototype was manufactured. Results obtained from the experiments were found to be in good agreement with the analytical study. A maximum error of 10% was recorded at noon. However, results show that error is less than 5% in early and late hours.
Determining GPS average performance metrics
NASA Technical Reports Server (NTRS)
Moore, G. V.
1995-01-01
Analytic and semi-analytic methods are used to show that users of the GPS constellation can expect performance variations based on their location. Specifically, performance is shown to be a function of both altitude and latitude. These results stem from the fact that the GPS constellation is itself non-uniform. For example, GPS satellites are over four times as likely to be directly over Tierra del Fuego than over Hawaii or Singapore. Inevitable performance variations due to user location occur for ground, sea, air and space GPS users. These performance variations can be studied in an average relative sense. A semi-analytic tool which symmetrically allocates GPS satellite latitude belt dwell times among longitude points is used to compute average performance metrics. These metrics include average number of GPS vehicles visible, relative average accuracies in the radial, intrack and crosstrack (or radial, north/south, east/west) directions, and relative average PDOP or GDOP. The tool can be quickly changed to incorporate various user antenna obscuration models and various GPS constellation designs. Among other applications, tool results can be used in studies to: predict locations and geometries of best/worst case performance, design GPS constellations, determine optimal user antenna location and understand performance trends among various users.
Li, Yubo; Zhang, Zhenzhu; Liu, Xinyu; Li, Aizhu; Hou, Zhiguo; Wang, Yuming; Zhang, Yanjun
2015-08-28
This study combines solid phase extraction (SPE) using 96-well plates with column-switching technology to construct a rapid and high-throughput method for the simultaneous extraction and non-targeted analysis of small molecules metabolome and lipidome based on ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry. This study first investigated the columns and analytical conditions for small molecules metabolome and lipidome, separated by an HSS T3 and BEH C18 columns, respectively. Next, the loading capacity and actuation duration of SPE were further optimized. Subsequently, SPE and column switching were used together to rapidly and comprehensively analyze the biological samples. The experimental results showed that the new analytical procedure had good precision and maintained sample stability (RSD<15%). The method was then satisfactorily applied to more widely analyze the small molecules metabolome and lipidome to test the throughput. The resulting method represents a new analytical approach for biological samples, and a highly useful tool for researches in metabolomics and lipidomics. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Le Doussal, Pierre; Petković, Aleksandra; Wiese, Kay Jörg
2012-06-01
We study the motion of an elastic object driven in a disordered environment in presence of both dissipation and inertia. We consider random forces with the statistics of random walks and reduce the problem to a single degree of freedom. It is the extension of the mean-field Alessandro-Beatrice- Bertotti-Montorsi (ABBM) model in presence of an inertial mass m. While the ABBM model can be solved exactly, its extension to inertia exhibits complicated history dependence due to oscillations and backward motion. The characteristic scales for avalanche motion are studied from numerics and qualitative arguments. To make analytical progress, we consider two variants which coincide with the original model whenever the particle moves only forward. Using a combination of analytical and numerical methods together with simulations, we characterize the distributions of instantaneous acceleration and velocity, and compare them in these three models. We show that for large driving velocity, all three models share the same large-deviation function for positive velocities, which is obtained analytically for small and large m, as well as for m=6/25. The effect of small additional thermal and quantum fluctuations can be treated within an approximate method.
Putting climate impact estimates to work: the empirical approach of the American Climate Prospectus
NASA Astrophysics Data System (ADS)
Jina, A.; Hsiang, S. M.; Kopp, R. E., III; Rasmussen, D.; Rising, J.
2014-12-01
The American Climate Prospectus (ACP), the technical analysis underlying the Risky Business project, quantitatively assesses climate risks posed to the United States' economy in a number of sectors [1]. Four of these - crop yield, crime, labor productivity, and mortality - draw upon research which identifies social impacts using contemporary variability in climate. We first identify a group of rigorous studies that use climate variability to identify responses to temperature and precipitation, while controlling for unobserved differences between locations. To incorporate multiple studies from a single sector, we employ a meta-analytical approach that draws on Bayesian methods commonly used in medical research and previously implemented in [2]. We generate a series of aggregate response functions for each sector using this meta-analytical method. We combine response functions with downscaled physical climate projections to estimate climate impacts out to the end of the century, incorporating uncertainty from statistical estimates, weather, climate models, and different emissions scenarios. Incorporating multiple studies in a single estimation framework allows us to directly compare impacts across the economy. We find that increased mortality has the largest effect on the US economy, followed by costs associated with decreased labor productivity. Agricultural losses and increases in crime contribute lesser but nonetheless substantial costs, and agriculture, notably, shows many areas benefitting from projected climate changes. The ACP also presents results throughout the 21stcentury. The dynamics of each of the impact categories differs, with, for example, mortality showing little change until the end of the century, but crime showing a monotonic increase from the present day. The ACP approach can expand to include new findings in current sectors, new sectors, and new geographical areas of interest. It represents an analytical framework that can incorporate empirical studies into a broad characterization of climate impacts across an economy, ensuring that each individual study can contribute to guiding policy priorities on climate change. References: [1] T. Houser et al. (2014), American Climate Prospectus, www.climateprospectus.org. [2] Hsiang, Burke, and Miguel (2013), Science.
The Statistical Value of Raw Fluorescence Signal in Luminex xMAP Based Multiplex Immunoassays
Breen, Edmond J.; Tan, Woei; Khan, Alamgir
2016-01-01
Tissue samples (plasma, saliva, serum or urine) from 169 patients classified as either normal or having one of seven possible diseases are analysed across three 96-well plates for the presences of 37 analytes using cytokine inflammation multiplexed immunoassay panels. Censoring for concentration data caused problems for analysis of the low abundant analytes. Using fluorescence analysis over concentration based analysis allowed analysis of these low abundant analytes. Mixed-effects analysis on the resulting fluorescence and concentration responses reveals a combination of censoring and mapping the fluorescence responses to concentration values, through a 5PL curve, changed observed analyte concentrations. Simulation verifies this, by showing a dependence on the mean florescence response and its distribution on the observed analyte concentration levels. Differences from normality, in the fluorescence responses, can lead to differences in concentration estimates and unreliable probabilities for treatment effects. It is seen that when fluorescence responses are normally distributed, probabilities of treatment effects for fluorescence based t-tests has greater statistical power than the same probabilities from concentration based t-tests. We add evidence that the fluorescence response, unlike concentration values, doesn’t require censoring and we show with respect to differential analysis on the fluorescence responses that background correction is not required. PMID:27243383
Peters, Ruud J B; van Bemmel, Greet; Herrera-Rivera, Zahira; Helsper, Hans P F G; Marvin, Hans J P; Weigel, Stefan; Tromp, Peter C; Oomen, Agnes G; Rietveld, Anton G; Bouwmeester, Hans
2014-07-09
Titanium dioxide (TiO2) is a common food additive used to enhance the white color, brightness, and sometimes flavor of a variety of food products. In this study 7 food grade TiO2 materials (E171), 24 food products, and 3 personal care products were investigated for their TiO2 content and the number-based size distribution of TiO2 particles present in these products. Three principally different methods have been used to determine the number-based size distribution of TiO2 particles: electron microscopy, asymmetric flow field-flow fractionation combined with inductively coupled mass spectrometry, and single-particle inductively coupled mass spectrometry. The results show that all E171 materials have similar size distributions with primary particle sizes in the range of 60-300 nm. Depending on the analytical method used, 10-15% of the particles in these materials had sizes below 100 nm. In 24 of the 27 foods and personal care products detectable amounts of titanium were found ranging from 0.02 to 9.0 mg TiO2/g product. The number-based size distributions for TiO2 particles in the food and personal care products showed that 5-10% of the particles in these products had sizes below 100 nm, comparable to that found in the E171 materials. Comparable size distributions were found using the three principally different analytical methods. Although the applied methods are considered state of the art, they showed practical size limits for TiO2 particles in the range of 20-50 nm, which may introduce a significant bias in the size distribution because particles <20 nm are excluded. This shows the inability of current state of the art methods to support the European Union recommendation for the definition of nanomaterials.
NASA Technical Reports Server (NTRS)
Simonson, M. R.; Smith, E. G.; Uhl, W. R.
1974-01-01
Analytical and experimental studies were performed to define the flowfield of annular jets, with and, without swirling flow. The analytical model treated configurations with variations of flow angularities, radius ratio, and swirl distributions. Swirl distributions characteristic of stator vanes and rotor blade rows, where the total pressure and swirl distributions are related were incorporated in the mathematical model. The experimental studies included tests of eleven nozzle models, both with and, without swirling exhaust flow. Flowfield surveys were obtained and used for comparison with the analytical model. This comparison of experimental and analytical studies served as the basis for evaluation of several empirical constants as required for application of the analysis to the general flow configuration. The analytical model developed during these studies is applicable to the evaluation of the flowfield and overall performance of the exhaust of statorless lift fan systems that contain various levels of exhaust swirl.
100-B/C Target Analyte List Development for Soil
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.W. Ovink
2010-03-18
This report documents the process used to identify source area target analytes in support of the 100-B/C remedial investigation/feasibility study addendum to DOE/RL-2008-46. This report also establishes the analyte exclusion criteria applicable for 100-B/C use and the analytical methods needed to analyze the target analytes.
Analytical electron microscope study of the omega phase transformation in a zirconium-niobium alloy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaluzec, N. J.
1979-01-01
The study of the as-quenched omega phase morphology shows that the domain size of Zr-15% Nb is on the order of 30 A. No alignment of omega domains along <222>..beta.. directions was observed and samples having undergone thermal cycling in thin foil form, did not develop a long-period structure of alternating ..beta.. and ..omega.. phases below the omega transformation temperature. (FS)
Bhui, Kamaldeep S.; Dinos, Sokratis; Stansfeld, Stephen A.; White, Peter D.
2012-01-01
Background. Psychosocial stressors in the workplace are a cause of anxiety and depressive illnesses, suicide and family disruption. Methods. The present review synthesizes the evidence from existing systematic reviews published between 1990 and July 2011. We assessed the effectiveness of individual, organisational and mixed interventions on two outcomes: mental health and absenteeism. Results. In total, 23 systematic reviews included 499 primary studies; there were 11 meta-analyses and 12 narrative reviews. Meta-analytic studies found a greater effect size of individual interventions on individual outcomes. Organisational interventions showed mixed evidence of benefit. Organisational programmes for physical activity showed a reduction in absenteeism. The findings from the meta-analytic reviews were consistent with the findings from the narrative reviews. Specifically, cognitive-behavioural programmes produced larger effects at the individual level compared with other interventions. Some interventions appeared to lead to deterioration in mental health and absenteeism outcomes.Gaps in the literature include studies of organisational outcomes like absenteeism, the influence of specific occupations and size of organisations, and studies of the comparative effectiveness of primary, secondary and tertiary prevention. Conclusions. Individual interventions (like CBT) improve individuals' mental health. Physical activity as an organisational intervention reduces absenteeism. Research needs to target gaps in the evidence. PMID:22496705
Bhui, Kamaldeep S; Dinos, Sokratis; Stansfeld, Stephen A; White, Peter D
2012-01-01
Psychosocial stressors in the workplace are a cause of anxiety and depressive illnesses, suicide and family disruption. The present review synthesizes the evidence from existing systematic reviews published between 1990 and July 2011. We assessed the effectiveness of individual, organisational and mixed interventions on two outcomes: mental health and absenteeism. In total, 23 systematic reviews included 499 primary studies; there were 11 meta-analyses and 12 narrative reviews. Meta-analytic studies found a greater effect size of individual interventions on individual outcomes. Organisational interventions showed mixed evidence of benefit. Organisational programmes for physical activity showed a reduction in absenteeism. The findings from the meta-analytic reviews were consistent with the findings from the narrative reviews. Specifically, cognitive-behavioural programmes produced larger effects at the individual level compared with other interventions. Some interventions appeared to lead to deterioration in mental health and absenteeism outcomes.Gaps in the literature include studies of organisational outcomes like absenteeism, the influence of specific occupations and size of organisations, and studies of the comparative effectiveness of primary, secondary and tertiary prevention. Individual interventions (like CBT) improve individuals' mental health. Physical activity as an organisational intervention reduces absenteeism. Research needs to target gaps in the evidence.
Low velocity impact analysis of composite laminated plates
NASA Astrophysics Data System (ADS)
Zheng, Daihua
2007-12-01
In the past few decades polymer composites have been utilized more in structures where high strength and light weight are major concerns, e.g., aircraft, high-speed boats and sports supplies. It is well known that they are susceptible to damage resulting from lateral impact by foreign objects, such as dropped tools, hail and debris thrown up from the runway. The impact response of the structures depends not only on the material properties but also on the dynamic behavior of the impacted structure. Although commercial software is capable of analyzing such impact processes, it often requires extensive expertise and rigorous training for design and analysis. Analytical models are useful as they allow parametric studies and provide a foundation for validating the numerical results from large-scale commercial software. Therefore, it is necessary to develop analytical or semi-analytical models to better understand the behaviors of composite structures under impact and their associated failure process. In this study, several analytical models are proposed in order to analyze the impact response of composite laminated plates. Based on Meyer's Power Law, a semi-analytical model is obtained for small mass impact response of infinite composite laminates by the method of asymptotic expansion. The original nonlinear second-order ordinary differential equation is transformed into two linear ordinary differential equations. This is achieved by neglecting high-order terms in the asymptotic expansion. As a result, the semi-analytical solution of the overall impact response can be applied to contact laws with varying coefficients. Then an analytical model accounting for permanent deformation based on an elasto-plastic contact law is proposed to obtain the closed-form solutions of the wave-controlled impact responses of composite laminates. The analytical model is also used to predict the threshold velocity for delamination onset by combining with an existing quasi-static delamination criterion. The predictions are compared with experimental data and explicit finite element LS-DYNA simulation. The comparisons show reasonable agreement. Furthermore, an analytical model is developed to evaluate the combined effects of prestresses and permanent deformation based on the linearized elasto-plastic contact law and the Laplace Transform technique. It is demonstrated that prestresses do not have noticeable effects on the time history of contact force and strains, but they have significant consequences on the plate central displacement. For a impacted composite laminate with the presence of prestresses, the contact force increases with the increasing of the mass of impactor, thickness and interlaminar shear strength of the laminate. The combined analytical and numerical investigations provide validated models for elastic and elasto-plastic impact analysis of composite structures and shed light on the design of impact-resistant composite systems.
Kipper, Karin; Barker, Charlotte I S; Standing, Joseph F; Sharland, Mike; Johnston, Atholl
2018-01-01
Penicillins are widely used to treat infections in children; however, the evidence is continuing to evolve in defining the optimal dosing. Modern pediatric pharmacokinetic study protocols frequently favor opportunistic, "scavenged" sampling. This study aimed to develop a small-volume single assay for five major penicillins and to assess the influence of sample degradation on inferences made using pharmacokinetic modeling, to investigate the suitability of scavenged sampling strategies. Using a rapid ultrahigh-performance liquid chromatographic-tandem mass spectrometric method, an assay for five penicillins (amoxicillin, ampicillin, benzylpenicillin, piperacillin, and flucloxacillin) in blood plasma was developed and validated. Penicillin stabilities were evaluated under different conditions. Using these data, the impact of drug degradation on inferences made during pharmacokinetic modeling was evaluated. All evaluated penicillins indicated good stability at room temperature (23 ± 2°C) over 1 h, remaining in the range of 98 to 103% of the original concentration. More-rapid analyte degradation had already occurred after 4 h, with stability ranging from 68% to 99%. Stability over longer periods declined: degradation of up to 60% was observed with delayed sample processing of up to 24 h. Modeling showed that analyte degradation can lead to a 30% and 28% bias in clearance and volume of distribution, respectively, and falsely show nonlinearity in clearance. Five common penicillins can now be measured in a single low-volume blood sample. Beta-lactam chemical instability in plasma can cause misleading pharmacokinetic modeling results, which could impact upon model-based dosing recommendations and the forthcoming era of beta-lactam therapeutic drug monitoring. Copyright © 2017 American Society for Microbiology.
Baum, John M; Monhaut, Nanette M; Parker, Donald R; Price, Christopher P
2006-06-01
Two independent studies reported that 16% of people who self-monitor blood glucose used incorrectly coded meters. The degree of analytical error, however, was not characterized. Our study objectives were to demonstrate that miscoding can cause analytical errors and to characterize the potential amount of bias that can occur. The impact of calibration error with three selfblood glucose monitoring systems (BGMSs), one of which has an autocoding feature, is reported. Fresh capillary fingerstick blood from 50 subjects, 18 men and 32 women ranging in age from 23 to 82 years, was used to measure glucose with three BGMSs. Two BGMSs required manual coding and were purposely miscoded using numbers different from the one recommended for the reagent lot used. Two properly coded meters of each BGMS were included to assess within-system variability. Different reagent lots were used to challenge a third system that had autocoding capability and could not be miscoded. Some within-system comparisons showed deviations of greater than +/-30% when results obtained with miscoded meters were compared with data obtained with ones programmed using the correct code number. Similar erroneous results were found when the miscoded meter results were compared with those obtained with a glucose analyzer. For some miscoded meter and test strip combinations, error grid analysis showed that 90% of results fell into zones indicating altered clinical action. Such inaccuracies were not found with the BGMS having the autocoding feature. When certain meter code number settings of two BGMSs were used in conjunction with test strips having code numbers that did not match, statistically and clinically inaccurate results were obtained. Coding errors resulted in analytical errors of greater than +/-30% (-31.6 to +60.9%). These results confirm the value of a BGMS with an automatic coding feature.
Buvé, Carolien; Van Bedts, Tine; Haenen, Annelien; Kebede, Biniam; Braekers, Roel; Hendrickx, Marc; Van Loey, Ann; Grauwet, Tara
2018-07-01
Accurate shelf-life dating of food products is crucial for consumers and industries. Therefore, in this study we applied a science-based approach for shelf-life assessment, including accelerated shelf-life testing (ASLT), acceptability testing and the screening of analytical attributes for fast shelf-life predictions. Shelf-stable strawberry juice was selected as a case study. Ambient storage (20 °C) had no effect on the aroma-based acceptance of strawberry juice. The colour-based acceptability decreased during storage under ambient and accelerated (28-42 °C) conditions. The application of survival analysis showed that the colour-based shelf-life was reached in the early stages of storage (≤11 weeks) and that the shelf-life was shortened at higher temperatures. None of the selected attributes (a * and ΔE * value, anthocyanin and ascorbic acid content) is an ideal analytical marker for shelf-life predictions in the investigated temperature range (20-42 °C). Nevertheless, an overall analytical cut-off value over the whole temperature range can be selected. Colour changes of strawberry juice during storage are shelf-life limiting. Combining ASLT with acceptability testing allowed to gain faster insight into the change in colour-based acceptability and to perform shelf-life predictions relying on scientific data. An analytical marker is a convenient tool for shelf-life predictions in the context of ASLT. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Experimental and analytical study of close-coupled ventral nozzles for ASTOVL aircraft
NASA Technical Reports Server (NTRS)
Mcardle, Jack G.; Smith, C. Frederic
1990-01-01
Flow in a generic ventral nozzle system was studied experimentally and analytically with a block version of the PARC3D computational fluid dynamics program (a full Navier-Stokes equation solver) in order to evaluate the program's ability to predict system performance and internal flow patterns. For the experimental work a one-third-size model tailpipe with a single large rectangular ventral nozzle mounted normal to the tailpipe axis was tested with unheated air at steady-state pressure ratios up to 4.0. The end of the tailpipe was closed to simulate a blocked exhaust nozzle. Measurements showed about 5 1/2 percent flow-turning loss, reasonable nozzle performance coefficients, and a significant aftward axial component of thrust due to flow turning loss, reasonable nozzle performance coefficients, and a significant aftward axial component of thrust due to flow turning more than 90 deg. Flow behavior into and through the ventral duct is discussed and illustrated with paint streak flow visualization photographs. For the analytical work the same ventral system configuration was modeled with two computational grids to evaluate the effect of grid density. Both grids gave good results. The finer-grid solution produced more detailed flow patterns and predicted performance parameters, such as thrust and discharge coefficient, within 1 percent of the measured values. PARC3D flow visualization images are shown for comparison with the paint streak photographs. Modeling and computational issues encountered in the analytical work are discussed.