Development of Optimal Stressor Scenarios for New Operational Energy Systems
2017-12-01
Analyzing the previous model using a design of experiments (DOE) and regression analysis provides critical information about the associated operational...from experimentation. The resulting system requirements can be used to revisit the design requirements and develop a more robust system. This process...stressor scenarios for acceptance testing. Analyzing the previous model using a design of experiments (DOE) and regression analysis provides critical
NASA Astrophysics Data System (ADS)
Simola, Kaisa; Laakso, Kari
1992-01-01
Eight years of operating experiences of 104 motor operated closing valves in different safety systems in nuclear power units were analyzed in a systematic way. The qualitative methods used were Failure Mode and Effect Analysis (FMEA) and Maintenance Effects and Criticality Analysis (MECA). These reliability engineering methods are commonly used in the design stage of equipment. The successful application of these methods for analysis and utilization of operating experiences was demonstrated.
The Role of First Impression in Operant Learning
ERIC Educational Resources Information Center
Shteingart, Hanan; Neiman, Tal; Loewenstein, Yonatan
2013-01-01
We quantified the effect of first experience on behavior in operant learning and studied its underlying computational principles. To that goal, we analyzed more than 200,000 choices in a repeated-choice experiment. We found that the outcome of the first experience has a substantial and lasting effect on participants' subsequent behavior, which we…
NASA Astrophysics Data System (ADS)
Chen, Yu-dan; Zhou, Bing; Ying, Jia-ju; Mao, Shao-juan; Qian, Xian-mei
2015-10-01
As one of the main weapons, impulse laser rangefinders have become the main object of the electro-optical countermeasures. So its real maximum range (defined as utmost operating range in the paper) becomes the most concerned index to evaluate the performance of electro-optical countermeasure weapons. A method for calculating laser rangefinders' utmost operating range by its sensitivity in different weather is obtained. Then a method by experiment for getting the sensitivity is supplied. By analyzing the experiment data which the detectivity is 40%-60%, the laser rangefinders' sensitivity is in the range of 1.7×10-5 W to 9.8×10-5 W. For the reason that in order to get an exact utmost operating range, the experiment accuracy of sensitivity is very important, in the last part of paper, the factors which influence the experiment accuracy of sensitivity are analyzed, such as circuit of automatic gain control, the fluctuation of laser power, incident angle of laser.
Impact of the 80-hour work week on resident emergency operative experience.
Feanny, Mark A; Scott, Bradford G; Mattox, Kenneth L; Hirshberg, Asher
2005-12-01
The goal of this study was to analyze the impact of the 80-hour work week on the emergency operative experience of surgical residents. A 2-year retrospective comparison of the operative experience in emergency abdominal procedures of postgraduate year 4 and 5 residents in a city hospital before (group 1) and after (group 2) duty hour restriction. There was no difference between groups in the mean number of procedures performed as the primary surgeon, but group 2 showed a 40% decrease in technically advanced procedures with a 44% increase in basic procedures. The study also demonstrated a 54% decrease in the operative volume as first assistant. Operative continuity of care by residents decreased from 60% to 26% of cases. The ACGME regulatory environment is adversely affecting the emergency operative experience of surgical residents. Our findings underscore the need to develop alternative methods to augment the residents' operative experience.
The University of Colorado OSO-8 spectrometer experiment. IV - Mission operations
NASA Technical Reports Server (NTRS)
Hansen, E. R.; Bruner, E. C., Jr.
1979-01-01
The remote operation of two high-resolution ultraviolet spectrometers on the OSO-8 satellite is discussed. Mission operations enabled scientific observers to plan observations based on current solar data, interact with the observing program using real- or near real-time data and commands, evaluate quick-look instrument data, and analyze the observations for publication. During routine operations, experiments were planned a day prior to their execution, and the data from these experiments received a day later. When a shorter turnaround was required, a real-time mode was available. Here, the real-time data and command links into the remote control center were used to evaluate experiment operation and make satellite pointing or instrument configuration changes with a 1-90 minute turnaround.
[Operating Room Nurses' Experiences of Securing for Patient Safety].
Park, Kwang Ok; Kim, Jong Kyung; Kim, Myoung Sook
2015-10-01
This study was done to evaluate the experience of securing patient safety in hospital operating rooms. Experiential data were collected from 15 operating room nurses through in-depth interviews. The main question was "Could you describe your experience with patient safety in the operating room?". Qualitative data from the field and transcribed notes were analyzed using Strauss and Corbin's grounded theory methodology. The core category of experience with patient safety in the operating room was 'trying to maintain principles of patient safety during high-risk surgical procedures'. The participants used two interactional strategies: 'attempt continuous improvement', 'immersion in operation with sharing issues of patient safety'. The results indicate that the important factors for ensuring the safety of patients in the operating room are manpower, education, and a system for patient safety. Successful and safe surgery requires communication, teamwork and recognition of the importance of patient safety by the surgical team.
Computer code for analyzing the performance of aquifer thermal energy storage systems
NASA Astrophysics Data System (ADS)
Vail, L. W.; Kincaid, C. T.; Kannberg, L. D.
1985-05-01
A code called Aquifer Thermal Energy Storage System Simulator (ATESSS) has been developed to analyze the operational performance of ATES systems. The ATESSS code provides an ability to examine the interrelationships among design specifications, general operational strategies, and unpredictable variations in the demand for energy. The uses of the code can vary the well field layout, heat exchanger size, and pumping/injection schedule. Unpredictable aspects of supply and demand may also be examined through the use of a stochastic model of selected system parameters. While employing a relatively simple model of the aquifer, the ATESSS code plays an important role in the design and operation of ATES facilities by augmenting experience provided by the relatively few field experiments and demonstration projects. ATESSS has been used to characterize the effect of different pumping/injection schedules on a hypothetical ATES system and to estimate the recovery at the St. Paul, Minnesota, field experiment.
An Analysis of Skill Requirements for Operators of Amphibious Air Cushion Vehicles (ACVs).
ERIC Educational Resources Information Center
McKnight, A. James; And Others
This report describes the skills required in the operation of an amphibious air cushion vehicle (ACV) in Army tactical and logistic missions. The research involved analyzing ACV characteristics, operating requirements, environmental effects, and results of a simulation experiment. The analysis indicates that ACV operation is complicated by an…
Skinner, Adrian; Maoate, Kiki; Beasley, Spencer
2010-05-01
Laparoscopic nephrectomy is an accepted alternative to open nephrectomy. We analyzed our first 80 procedures of laparoscopic nephrectomy to evaluate the effect of experience and configuration of service on operative times. A retrospective review of 80 consecutive children who underwent retroperitoneal laparoscopic nephrectomy or heminephrectomy during an 11-year period from 1997 at Christchurch Hospital (Christchurch, New Zealand) was conducted. Operative times, in relation to the experience of the surgeon for this procedure, were analyzed. Four surgeons, assisted by an annually rotating trainee registrar, performed the procedure in 26 girls and 54 boys (range, 8 months to 15 years). Operating times ranged from 38 to 225 minutes (mean, 104). The average operative time fell from 105 to 90 minutes. One surgeon performed 40% of the procedures and assisted with a further 55%. The operative times for all surgeons showed a tendency to reduce, but this was not marked. Most procedures were performed by two surgeons working together, although one surgeon was involved in the majority of cases. The lead surgeon is often assisted by a fellow consultant colleague. Operative times were influenced by experience, but not markedly so. The shorter operative times and minimal "learning curve," compared with other reported series, may, in part, be due to the involvement of two surgeons experienced in laparoscopy for the majority of cases.
Shuttle sortie simulation using a Lear jet aircraft: Mission no. 1 (assess program)
NASA Technical Reports Server (NTRS)
Mulholland, D. R.; Reller, J. O., Jr.; Nell, C. B., Jr.; Mason, R. H.
1972-01-01
The shuttle sortie simulation mission of the Airborne Science/Shuttle Experiments System Simulation Program which was conducted using the CV-990 aircraft is reported. The seven flight, five day mission obtained data on experiment preparation, type of experiment components, operation and maintenance, data acquisition, crew functions, timelines and interfaces, use of support equipment and spare parts, power consumption, work cycles, influence of constraints, and schedule impacts. This report describes the experiment, the facilities, the operation, and the results analyzed from the standpoint of their possible use in aiding the planning for experiments in the Shuttle Sortie Laboratory.
A system for programming experiments and for recording and analyzing data automatically1
Herrick, Robert M.; Denelsbeck, John S.
1963-01-01
A system designed for use in complex operant conditioning experiments is described. Some of its key features are: (a) plugboards that permit the experimenter to change either from one program to another or from one analysis to another in less than a minute, (b) time-sharing of permanently-wired, electronic logic components, (c) recordings suitable for automatic analyses. Included are flow diagrams of the system and sample logic diagrams for programming experiments and for analyzing data. ImagesFig. 4. PMID:14055967
DOT National Transportation Integrated Search
1996-11-01
This report describes the proceedings of the Workshop on Human Factors Research held in Reston, Virginia. The : objectives of the workshop were to: foster an interchange of experience in measuring and analyzing operator performance : data; encourage ...
A "Greenhouse Gas" Experiment for the Undergraduate Laboratory
ERIC Educational Resources Information Center
Gomez, Elaine; Paul, Melissa; Como, Charles; Barat, Robert
2014-01-01
This experiment and analysis offer an effective experience in greenhouse gas reduction. Ammoniated water is flowed counter-current to a simulated flue gas of air and CO2 in a packed column. The gaseous CO2 concentrations are measured with an on-line, non- dispersive, infrared analyzer. Column operating parameters include total gas flux, dissolved…
NASA Technical Reports Server (NTRS)
Brook, M.
1986-01-01
An optical lightning detector was constructed and flown, along with Vinton cameras and a Fairchild Line Scan Spectrometer, on a U-2 during the summer of 1979. The U-2 lightning data was obtained in daylight, and was supplemented with ground truth taken at Langmuir Laboratory. Simulations were prepared as required to establish experiment operating procedures and science training for the astronauts who would operate the Night/Day Optical Survey of Thunderstorm Lightning (NOSL) equipment during the STS-2 NOSL experiment on the Space Shuttle. Data was analyzed and papers were prepared for publication.
Human Factors Operability Timeline Analysis to Improve the Processing Flow of the Orion Spacecraft
NASA Technical Reports Server (NTRS)
Schlierf, Roland; Stambolian, Damon B.; Miller, Darcy; Posanda, Juan; Haddock, Mike; Haddad, Mike; Tran, Donald; Henderson, Gena; Barth, Tim
2010-01-01
The Constellation Program (CxP) Orion vehicle goes through several areas and stages of processing before its launched at the Kennedy Space Center. In order to have efficient and effective processing, all of the activities need to be analyzed. This was accomplished by first developing a timeline of events that included each activity, and then each activity was analyzed by operability experts and human factors experts with spacecraft processing experience. This papers focus is to explain the results and the process for developing this human factors operability timeline analysis to improve the processing flow of Orion.
The Software Engineering Laboratory: An operational software experience factory
NASA Technical Reports Server (NTRS)
Basili, Victor R.; Caldiera, Gianluigi; Mcgarry, Frank; Pajerski, Rose; Page, Gerald; Waligora, Sharon
1992-01-01
For 15 years, the Software Engineering Laboratory (SEL) has been carrying out studies and experiments for the purpose of understanding, assessing, and improving software and software processes within a production software development environment at NASA/GSFC. The SEL comprises three major organizations: (1) NASA/GSFC, Flight Dynamics Division; (2) University of Maryland, Department of Computer Science; and (3) Computer Sciences Corporation, Flight Dynamics Technology Group. These organizations have jointly carried out several hundred software studies, producing hundreds of reports, papers, and documents, all of which describe some aspect of the software engineering technology that was analyzed in the flight dynamics environment at NASA. The studies range from small, controlled experiments (such as analyzing the effectiveness of code reading versus that of functional testing) to large, multiple project studies (such as assessing the impacts of Ada on a production environment). The organization's driving goal is to improve the software process continually, so that sustained improvement may be observed in the resulting products. This paper discusses the SEL as a functioning example of an operational software experience factory and summarizes the characteristics of and major lessons learned from 15 years of SEL operations.
Variable Operative Experience in Hand Surgery for Plastic Surgery Residents.
Silvestre, Jason; Lin, Ines C; Levin, Lawrence Scott; Chang, Benjamin
Efforts to standardize hand surgery training during plastic surgery residency remain challenging. We analyze the variability of operative hand experience at U.S. plastic surgery residency programs. Operative case logs of chief residents in accredited U.S. plastic surgery residency programs were analyzed (2011-2015). Trends in fold differences of hand surgery case volume between the 10th and 90th percentiles of residents were assessed graphically. Percentile data were used to calculate the number of residents achieving case minimums in hand surgery for 2015. Case logs from 818 plastic surgery residents were analyzed of which a minority were from integrated (35.7%) versus independent/combined (64.3%) residents. Trend analysis of fold differences in case volume demonstrated decreasing variability among procedure categories over time. By 2015, fold differences for hand reconstruction, tendon cases, nerve cases, arthroplasty/arthrodesis, amputation, arterial repair, Dupuytren release, and neoplasm cases were below 10-fold. Congenital deformity cases among independent/combined residents was the sole category that exceeded 10-fold by 2015. Percentile data suggested that approximately 10% of independent/combined residents did not meet case minimums for arterial repair and congenital deformity in 2015. Variable operative experience during plastic surgery residency may limit adequate exposure to hand surgery for certain residents. Future studies should establish empiric case minimums for plastic surgery residents to ensure hand surgery competency upon graduation. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
The Experience of Chief Nurse in Military Operations Other Than War.
1998-10-02
and analyzed using procedures adapted from Colaizzi (1978), Van Manen (1990) and illuminated by Ray (1990). Significant statements were identified in...experience will lead to an understanding of the foundations of the global caregiving community. Hermeneutic phenomenology provided a description and
Building a First-Class Faculty Based on the Management Experience of the University of Pennsylvania
ERIC Educational Resources Information Center
Luo, Zhongshu
2014-01-01
The article analyzes the practice and experience of faculty management at the University of Pennsylvania and its implications for Chinese universities from the perspective of management systems and operation mechanisms. Recent reforms and innovation of faculty management at Sichuan University are described.
Cesana, Giovanni; Cioffi, Stefano; Giorgi, Riccardo; Villa, Roberta; Uccelli, Matteo; Ciccarese, Francesca; Castello, Giorgio; Scotto, Bruno; Olmi, Stefano
2018-03-01
The purpose of this paper was to search for predictive factors for proximal leakage after laparoscopic sleeve gastrectomy (LSG) in a large cohort from a single referral center. One thousand seven hundred and thirty-eight patients, collected in a prospectively held database from 2008 to 2016, were retrospectively analyzed. The correlation between postoperative leakage and both preoperative (age, gender, height, weight, BMI, and obesity-related morbidities) and operative variables (the distance from pylorus at which the gastric section was started, operative time, experience of surgeons who performed the LSG, and the surgical materials used) was analyzed. The experience of the surgeons was calculated in the number of LSGs performed. The surgical materials considered were stapler, cartridges, and reinforcement of the suture. Proximal leakage was observed in 45 patients out of 1738 (2.6%). No correlation was found between leakage and the preoperative variables analyzed. The operative variables that were found to be associated with lower incidence of leakage at the multivariate analysis (p < 0.05) were the reinforcement of the staple line (or overriding suture or buttressing materials) and the experience of the surgeons. A distance of less than 2 cm from the pylorus resulted to be significantly related to a higher incidence of fistula at the univariate analysis. In this large consecutive cohort study of LSG, proximal staple line reinforcement (buttress material or suture) reduced the risk of a leak. The risk of a proximal leak was much higher in the surgeons first 100 cases, which has implications for training and supervision during this "learning curve" period.
Digital signal processing in the radio science stability analyzer
NASA Technical Reports Server (NTRS)
Greenhall, C. A.
1995-01-01
The Telecommunications Division has built a stability analyzer for testing Deep Space Network installations during flight radio science experiments. The low-frequency part of the analyzer operates by digitizing wave signals with bandwidths between 80 Hz and 45 kHz. Processed outputs include spectra of signal, phase, amplitude, and differential phase; time series of the same quantities; and Allan deviation of phase and differential phase. This article documents the digital signal-processing methods programmed into the analyzer.
NASA Astrophysics Data System (ADS)
Chakraborty, Abhishek
Detection of particulate matter thinly dispersed in a fluid medium with the aid of the difference in electrical conductivity between the pure fluid and the particles has been practiced at least since the last 50 to 60 years. The first such instruments were employed to measure cell counts in samples of biological fluid. Following a detailed study of the physics and principles operating within the device, called the Electric Sensing Zone (ESZ) principle, a new device called the Liquid Metal Cleanliness Analyzer (LiMCA) was invented which could measure and count particles of inclusions in molten metal. It provided a fast and fairly accurate tool to make online measurement of the quality of steel during refining and casting operations. On similar lines of development as the LiMCA, a water analogue of the device called, the Aqueous Particle Sensor (APS) was developed for physical modeling experiments of metal refining operations involving water models. The APS can detect and measure simulated particles of inclusions added to the working fluid (water). The present study involves the designing, building and final application of a new and improved APS in water modeling experiments to study inclusion behavior in a tundish operation. The custom built instrument shows superior performance and applicability in experiments involving physical modeling of metal refining operations, compared to its commercial counterparts. In addition to higher accuracy and range of operating parameters, its capability to take real-time experimental data for extended periods of time helps to reduce the total number of experiments required to reach a result, and makes it suitable for analyzing temporal changes occurring in unsteady systems. With the modern impetus on the quality of the final product of metallurgical operations, the new APS can prove to be an indispensable research tool to study and put forward innovative design and parametric changes in industrially practised metallurgical operations.
10 CFR 36.13 - Specific licenses for irradiators.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the training provided to irradiator operators including— (1) Classroom training; (2) On-the-job or... analysis; and (3) Pertinent experience of the individual who analyzes the samples. (g) If licensee...
Operational Improvements From the In-Trail Procedure in the North Atlantic Organized Track System
NASA Technical Reports Server (NTRS)
Chartrand, Ryan C.; Bussink, Frank J. L.; Graff, Thomas J.; Murdoch, Jennifer L.; Jones, Kenneth M.
2008-01-01
This paper explains the computerized batch processing experiment examining the operational impacts of the introduction of Automatic Dependent Surveillance-Broadcast (ADS-B) equipment and the In-Trail Procedure (ITP) to the North Atlantic Organized Track System (NATOTS). This experiment was conducted using the Traffic Manager (TMX), a desktop simulation capable of simulating airspace environments and aircraft operations. ADS-B equipment can enable the use of new ground and airborne procedures, such as the ITP. The ITP is among the first of these new procedures, which will make use of improved situation awareness in the local surrounding airspace of ADS-B equipped aircraft to enable more efficient oceanic flight level changes. The data collected were analyzed with respect to multiple operationally relevant parameters including fuel burn, request approval rates, and the distribution of fuel savings. This experiment showed that through the use of ADS-B or ADS-B and the ITP that operational improvements and benefits could be achieved.
NASA Technical Reports Server (NTRS)
Chartrand, Ryan C.; Bussink, Frank J.; Graff, Thomas J.; Jones, Kenneth M.
2009-01-01
This paper explains the computerized batch processing experiment examining the operational impacts of the introduction of Automatic Dependent Surveillance-Broadcast (ADS-B) equipment and the In-Trail Procedure (ITP) to the North Atlantic Organized Track System. This experiment was conducted using the Traffic Manager (TMX), a desktop simulation capable of simulating airspace environments and aircraft operations. ADS-B equipment can enable the use of new ground and airborne procedures, such as the ITP. ITP is among the first of these new procedures, which will make use of improved situation awareness in the local surrounding airspace of ADS-B equipped aircraft to enable more efficient oceanic flight level changes. The collected data were analyzed with respect to multiple operationally relevant parameters including fuel burn, request approval rates, and the distribution of fuel savings. This experiment showed that through the use of ADS-B or ADS-B and the ITP that operational improvements and benefits could be achieved.
Surgical experience and complications during endonasal sinus surgery.
Keerl, R; Stankiewicz, J; Weber, R; Hosemann, W; Draf, W
1999-04-01
The introduction of optical aids for endonasal sinus surgery has not produced the expected drop in the rate of serious intraoperative complications. 1. Retrospectively, consecutive procedures of different surgeons were analyzed in regard to major complications (periorbital injury, orbital lesion, dural injury, endocranial lesion, damage to the internal carotid artery). The chronological distribution was transformed into a personal learning curve. 2. From our own experience and as surveyors, we analyzed the experiences of surgeons having encountered severe complications and compared them with the above-mentioned learning curve. In total, 1,500 operations carried out by five surgeons with 16 serious complications were assessed. For the learning curve, the following stages were defined. stage I: greatest risk of complication, with dural injury (1st to 30th operation); stage II, slighter risk of complication, with frequent periorbital injuries (31st to 180th operation); and stage III, least risk, corresponding to an experienced surgeon. Serious complications occur most frequently among experienced surgeons. The beginner enjoys the most effective type of assistance, in the form of personal guidance of an experienced surgeon who is constantly present during the first 30 operations, and who should then be readily available during the next 70 operative procedures. The use of multimedia software appears to be helpful, though its actual value still remains to be determined. The experienced surgeon in particular must be willing to exercise repeated self-criticism to keep his or her rate of complications to a minimum.
Large-scale flow experiments for managing river systems
Konrad, Christopher P.; Olden, Julian D.; Lytle, David A.; Melis, Theodore S.; Schmidt, John C.; Bray, Erin N.; Freeman, Mary C.; Gido, Keith B.; Hemphill, Nina P.; Kennard, Mark J.; McMullen, Laura E.; Mims, Meryl C.; Pyron, Mark; Robinson, Christopher T.; Williams, John G.
2011-01-01
Experimental manipulations of streamflow have been used globally in recent decades to mitigate the impacts of dam operations on river systems. Rivers are challenging subjects for experimentation, because they are open systems that cannot be isolated from their social context. We identify principles to address the challenges of conducting effective large-scale flow experiments. Flow experiments have both scientific and social value when they help to resolve specific questions about the ecological action of flow with a clear nexus to water policies and decisions. Water managers must integrate new information into operating policies for large-scale experiments to be effective. Modeling and monitoring can be integrated with experiments to analyze long-term ecological responses. Experimental design should include spatially extensive observations and well-defined, repeated treatments. Large-scale flow manipulations are only a part of dam operations that affect river systems. Scientists can ensure that experimental manipulations continue to be a valuable approach for the scientifically based management of river systems.
NASA Astrophysics Data System (ADS)
Benítez Rodríguez, E.; Arévalo Aguilar, L. M.; Piceno Martínez, E.
2017-03-01
To the quantum mechanics specialists community it is a well-known fact that the famous original Stern-Gerlach experiment (SGE) produces entanglement between the external degrees of freedom (position) and the internal degree of freedom (spin) of silver atoms. Despite this fact, almost all textbooks on quantum mechanics explain this experiment using a semiclassical approach, where the external degrees of freedom are considered classical variables, the internal degree is treated as a quantum variable, and Newton's second law is used to describe the dynamics. In the literature there are some works that analyze this experiment in its full quantum mechanical form. However, astonishingly, to the best of our knowledge the original experiment, where the initial states of the spin degree of freedom are randomly oriented coming from the oven, has not been analyzed yet in the available textbooks using the Schrödinger equation (to the best of our knowledge there is only one paper that treats this case: Hsu et al (2011 Phys. Rev. A 83 012109)). Therefore, in this contribution we use the time-evolution operator to give a full quantum mechanics analysis of the SGE when the initial state of the internal degree of freedom is completely random, i.e. when it is a statistical mixture. Additionally, as the SGE and the development of quantum mechanics are heavily intermingled, we analyze some features and drawbacks in the current teaching of quantum mechanics. We focus on textbooks that use the SGE as a starting point, based on the fact that most physicist do not use results from physics education research, and comment on traditional pedagogical attitudes in the physics community.
Spacelab Mission Implementation Cost Assessment (SMICA)
NASA Technical Reports Server (NTRS)
Guynes, B. V.
1984-01-01
A total savings of approximately 20 percent is attainable if: (1) mission management and ground processing schedules are compressed; (2) the equipping, staffing, and operating of the Payload Operations Control Center is revised, and (3) methods of working with experiment developers are changed. The development of a new mission implementation technique, which includes mission definition, experiment development, and mission integration/operations, is examined. The Payload Operations Control Center is to relocate and utilize new computer equipment to produce cost savings. Methods of reducing costs by minimizing the Spacelab and payload processing time during pre- and post-mission operation at KSC are analyzed. The changes required to reduce costs in the analytical integration process are studied. The influence of time, requirements accountability, and risk on costs is discussed. Recommendation for cost reductions developed by the Spacelab Mission Implementation Cost Assessment study are listed.
Petrushnko, Wilson; Perry, Will; Fraser-Kirk, Grant; Ctercteko, Grahame; Adusumilli, Sanjay; O'Grady, Gregory
2015-12-01
Fellowships in surgery are increasing in number, and concerns have been raised regarding their impact on resident training. Although fellows may contribute to resident education and training, they also compete for operative and other experience. This study aimed to quantify the impact of fellowships on resident training in a binational multispecialty cohort. The operative case volumes and primary operator rates of surgery trainees (residents) in Australia and New Zealand were compared between units with and without fellows. Trainees also were surveyed using Likert Scales to assess quality of operative and other experience in units with and without fellows. Data from 911 trainees over 2 terms was analyzed; survey response rate 42%. Of all trainees, 42% worked with fellows. Trainees in units without fellows were involved in more major (P = .03) and minor (P < .0001) cases. Primary operator rates were comparable, but trainees in units without fellows were less often assistants, reported an increased quality of elective operating experience, and reported more favorable completion of learning objectives (all P < .05). These findings were consistent between tertiary and nontertiary hospitals. Thematic analysis showed positive benefits of fellows in teaching, training and mentorship, but negative impacts on case exposure, competition for operating, and clinical experience. Fellows may assist in the teaching and training of residents, but residents working with fellows experience a decreased quantity of operative experience that may impact several aspects of the quality of training. Surgical educators must actively balance the learning needs of fellows and residents. Copyright © 2015 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Erasmus, Daniel J.; Brewer, Sharon E.; Cinel, Bruno
2015-01-01
The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of…
Distribution and Supply Chain Management: Educating the Army Officer
2005-05-26
knowledge a logistics officer must have to function effectively in a supply chain and distribution management environment. It analyzes how officers...Educational Objectives. It discusses how the Army/DoD currently teaches supply chain and distribution management concepts in various programs, such as the...its educational curriculum, and that logisticians continue to gain operational experience in distribution management operations. The paper recommends
The V-Scope: An "Oscilloscope" for Motion.
ERIC Educational Resources Information Center
Ronen, Miky; Lipman, Aharon
1991-01-01
Proposes the V-Scope as a teaching aid to measure, analyze, and display three-dimensional multibody motion. Describes experiment setup considerations, how measurements are calculated, graphic representation capabilities, and modes of operation of this microcomputer-based system. (MDH)
The Large Area Crop Inventory Experiment /LACIE/ - An assessment after one year of operation
NASA Technical Reports Server (NTRS)
Macdonald, R. B.; Hall, F. G.; Erb, R. B.
1975-01-01
A Large Area Crop Inventory Experiment (LACIE) has been undertaken jointly by the U.S. Department of Agriculture (USDA), the National Oceanic and Atmospheric Administration (NOAA) of the Department of Commerce and the National Aeronautics and Space Administration (NASA) to prove out an economically important application of remote sensing from space. The first phase of the Experiment, which focused upon determinations of wheat area in the U.S. Great Plains and upon the development and testing of yield models, is now nearing completion. The system implemented to handle and analyze the Landsat and meteorological data has generally worked well and met operational goals. A very preliminary assessment of results to date indicates that the accuracy goals of the experiment can be met.
STS-41 Voice Command System Flight Experiment Report
NASA Technical Reports Server (NTRS)
Salazar, George A.
1981-01-01
This report presents the results of the Voice Command System (VCS) flight experiment on the five-day STS-41 mission. Two mission specialists,Bill Shepherd and Bruce Melnick, used the speaker-dependent system to evaluate the operational effectiveness of using voice to control a spacecraft system. In addition, data was gathered to analyze the effects of microgravity on speech recognition performance.
Recent advances in automatic alignment system for the National Ignition Facility
NASA Astrophysics Data System (ADS)
Wilhelmsen, Karl; Awwal, Abdul A. S.; Kalantar, Dan; Leach, Richard; Lowe-Webb, Roger; McGuigan, David; Miller Kamm, Vicki
2011-03-01
The automatic alignment system for the National Ignition Facility (NIF) is a large-scale parallel system that directs all 192 laser beams along the 300-m optical path to a 50-micron focus at target chamber in less than 50 minutes. The system automatically commands 9,000 stepping motors to adjust mirrors and other optics based upon images acquired from high-resolution digital cameras viewing beams at various locations. Forty-five control loops per beamline request image processing services running on a LINUX cluster to analyze these images of the beams and references, and automatically steer the beams toward the target. This paper discusses the upgrades to the NIF automatic alignment system to handle new alignment needs and evolving requirements as related to various types of experiments performed. As NIF becomes a continuously-operated system and more experiments are performed, performance monitoring is increasingly important for maintenance and commissioning work. Data, collected during operations, is analyzed for tuning of the laser and targeting maintenance work. Handling evolving alignment and maintenance needs is expected for the planned 30-year operational life of NIF.
Erasmus, Daniel J; Brewer, Sharon E; Cinel, Bruno
2015-01-01
The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of engagement, learning, and overall experience. Feedback from students suggests that the use of remote access technology is effective in teaching students the principles of chemical analysis by atomic absorption spectroscopy. © 2014 The International Union of Biochemistry and Molecular Biology.
A description of the verbal behavior of students during two reading instruction methods
Daly, Patricia M.
1987-01-01
The responses of students during two reading methods, the language experience approach and two Mastery Learning programs, were analyzed using verbal operants. A description of student responding was generated for these methods. The purpose of the study was to answer the questions: What are the major controlling variables determining student reading behavior during the language experience approach and two Mastery Learning programs, and how do these controlling variables change across story reading sessions and across stories in the first method? Student responses by verbal operant were compared for both reading methods. Findings indicated higher frequencies of textual operants occurred in responses during the Mastery Learning programs. A greater reliance on intraverbal control was evident in responses during the language experience approach. It is suggested that students who can generate strong intraverbal responses and who may have visual discrimination problems during early reading instruction may benefit from use of the language experience approach at this stage. ImagesFigure 2Figure 3 PMID:22477535
Cost analysis of life sciences experiments and subsystems. [to be carried in the Spacelab
NASA Technical Reports Server (NTRS)
Yakut, M. M.
1975-01-01
Cost estimates for experiments and subsystems flown in the Spacelab were established. Ten experiments were cost analyzed. Estimated cost varied from $650,000 for the hardware development of the SPE water electrolysis experiment to $78,500,000 for the development and operation of a representative life sciences laboratory program. The cost of subsystems for thermal, atmospheric and trace contaminants control of the Spacelab internal atmosphere was also estimated. Subsystem cost estimates were based on the utilization of existing components developed in previous space programs whenever necessary.
Stanley, Matthew D; Davenport, Daniel L; Procter, Levi D; Perry, Jacob E; Kearney, Paul A; Bernard, Andrew C
2011-03-01
Surgical resident rotations on trauma services are criticized for little operative experience and heavy workloads. This has resulted in diminished interest in trauma surgery among surgical residents. Acute care surgery (ACS) combines trauma and emergency/elective general surgery, enhancing operative volume and balancing operative and nonoperative effort. We hypothesize that a mature ACS service provides significant operative experience. A retrospective review was performed of ACGME case logs of 14 graduates from a major, academic, Level I trauma center program during a 3-year period. Residency Review Committee index case volumes during the fourth and fifth years of postgraduate training (PGY-4 and PGY-5) ACS rotations were compared with other service rotations: in total and per resident week on service. Ten thousand six hundred fifty-four cases were analyzed for 14 graduates. Mean cases per resident was 432 ± 57 in PGY-4, 330 ± 40 in PGY-5, and 761 ± 67 for both years combined. Mean case volume on ACS for both years was 273 ± 44, which represented 35.8% (273 of 761) of the total experience and exceeded all other services. Residents averaged 8.9 cases per week on the ACS service, which exceeded all other services except private general surgery, gastrointestinal/minimally invasive surgery, and pediatric surgery rotations. Disproportionately more head/neck, small and large intestine, gastric, spleen, laparotomy, and hernia cases occurred on ACS than on other services. Residents gain a large operative experience on ACS. An ACS model is viable in training, provides valuable operative experience, and should not be considered a drain on resident effort. Valuable ACS rotation experiences as a resident may encourage graduates to pursue ACS as a career. Copyright © 2011 by Lippincott Williams & Wilkins
Activities at the JSC Payload Operations Control Center During Spacelab Mission
NASA Technical Reports Server (NTRS)
1984-01-01
During a Spacelab flight, the hub of activity was the Payload Operations Control Center (POCC) at the Johnson Space Flight Center (JSC) in Houston, Texas. The POCC became home to the management and science teams who worked around the clock to guide and support the mission. All Spacelab principal investigators and their teams of scientists and engineers set up work areas in the POCC. Through the use of computers, they could send commands to their instruments and receive and analyze experiment data. Instantaneous video and audio communications made it possible for scientists on the ground to follow the progress of their research almost as if they were in space with the crew. This real-time interaction between investigators on the ground and the crew in space was probably the most exciting of Spacelab's many capabilities. As principal investigators talked to the payload specialists during the mission, they consulted on experiment operations, made decisions, and shared in the thrill of gaining new knowledge. In December 1990, a newly-established POCC at the Marshall Space Flight Center (MSFC) opened its door for the operations of the Spacelab payloads and experiments, while JSC monitored the Shuttle flight operations. MSFC had managing responsibilities for the Spacelab missions.
National Parks of New York Harbor Traveler Information System: Concept of Operations
DOT National Transportation Integrated Search
2011-12-23
The purpose of this planning project is to analyze alternatives and design a Traveler Information System (TIS) that will enhance the experience of visitors to the NYNH parks and other sites managed by federal, state and local partners. The system wil...
Disparities in Aesthetic Procedures Performed by Plastic Surgery Residents.
Silvestre, Jason; Serletti, Joseph M; Chang, Benjamin
2017-05-01
Operative experience in aesthetic surgery is an important issue affecting plastic surgery residents. This study addresses the variability of aesthetic surgery experience during plastic surgery residency. National operative case logs of chief residents in independent/combined and integrated plastic surgery residency programs were analyzed (2011-2015). Fold differences between the bottom and top 10th percentiles of residents were calculated for each aesthetic procedure category and training model. The number of residents not achieving case minimums was also calculated. Case logs of 818 plastic surgery residents were analyzed. There was marked variability in craniofacial (range, 6.0-15.0), breast (range, 2.4-5.9), trunk/extremity (range, 3.0-16.0), and miscellaneous (range, 2.7-22.0) procedure categories. In 2015, the bottom 10th percentile of integrated and independent/combined residents did not achieve case minimums for botulinum toxin and dermal fillers. Case minimums were achieved for the other aesthetic procedure categories for all graduating years. Significant variability persists for many aesthetic procedure categories during plastic surgery residency training. Greater efforts may be needed to improve the aesthetic surgery experience of plastic surgery residents. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com
Dobrinja, Chiara; Trevisan, Giuliano; Liguori, Gennaro
2009-03-01
The aim of this study is to analyze our preliminary results from minimally invasive video-assisted thyroidectomy (MIVAT) and demonstrate the feasibility of MIVAT also in non-referral centers. We report our initial experience based on a series of 47 patients selected for MIVAT at General Surgery Department of University of Trieste during a period from May 2005 to February 2007. The eligibility criteria were rigorously observed. Age, goiter volume, major diameter of the dominant nodule, operative times, pathologic findings, postoperative pain, length of hospital stay, cosmetic results, and complications were retrospectively analyzed. Thyroid lobectomy was successfully accomplished in 33 cases, total thyroidectomy in 14. Conversion to standard cervicotomy was required in three patients (6%). Mean operative time of lobectomy was 82.6 min and 118.7 for total thyroidectomy. Postoperative complications included 11 (23.4%) transient hypocalcemias, 2 (4.2%) hematomas, and 2 (4.2%) temporary laryngeal nerve palsies. None-recurrent nerve palsies was observed. The cosmetic result was excellent in most cases. Our experience demonstrates that MIVAT, after adequate training, is feasible and safe, with results comparable to conventional thyroidectomy, also in a General Surgery Department, from a dedicated team, with a sufficient and specific activity volume.
NASA Technical Reports Server (NTRS)
Spinhirne, James M; Scott, V. Stan; Lancaster, Redgie S.; Manizade, Kathrine; Palm, Steven P.
2000-01-01
The Infrared Spectral Imaging Radiometer experiment was flown on a space shuttle mission as a shuttle hitchhiker experiment in August of 1997. The goals of the experiment were to test uncooled array detectors for infrared spectral imaging from space and to apply for the first time retrieval from space of brightness temperatures of cloud, land and sea along with direct laser measurements of cloud top height. The instrument operates in 3 narrow and one broad spectral band, all between 7 and 13 microns in either stare or time-delay and integration mode. The nominal spatial resolution was 1/4 kilometer. Using onboard calibrations along with periodic views of deep space, radiometric calibration of imagery was carried out and performance analyzed. The noise equivalent temperature difference and absolute accuracy reported here varied with operating mode, spectral band and scene temperature but were within requirements. This paper provides a description of the instrument, its operating modes, the method of brightness temperature retrieval, the method of spectral registration and results from the flight.
Hargreaves, Sarah; Bath, Peter A; Duffin, Suzanne; Ellis, Julie
2018-06-14
The availability of an increasing number of online health forums has altered the experience of living with a health condition, as more people are now able to connect and support one another. Empathy is an important component of peer-to-peer support, although little is known about how empathy develops and operates within online health forums. The aim of this paper is to explore how empathy develops and operates within two online health forums for differing health conditions: breast cancer and motor neuron disease (MND), also known as amyotrophic lateral sclerosis. This qualitative study analyzed data from two sources: interviews with forum users and downloaded forum posts. Data were collected from two online health forums provided by UK charities: Breast Cancer Care and the Motor Neurone Disease Association. We analyzed 84 threads from the breast cancer forum and 52 from the MND forum. Threads were purposively sampled to reflect varied experiences (eg, illness stages, topics of conversation, and user characteristics). Semistructured interviews were conducted with 14 Breast Cancer Care forum users and five users of the MND forum. All datasets were analyzed thematically using Braun and Clarke's six-phase approach and combined to triangulate the analysis. We found that empathy develops and operates through shared experiences and connections. The development of empathy begins outside the forum with experiences of illness onset and diagnosis, creating emotional and informational needs. Users came to the forum and found their experiences and needs were shared and understood by others, setting the empathetic tone and supportive ethos of the forum. The forum was viewed as both a useful and meaningful space in which they could share experiences, information, and emotions, and receive empathetic support within a supportive and warm atmosphere. Empathy operated through connections formed within this humane space based on similarity, relationships, and shared feelings. Users felt a need to connect to users who they felt were like themselves (eg, people sharing the same specific diagnosis). They formed relationships with other users. They connected based on the emotional understanding of ill health. Within these connections, empathic communication flourished. Empathy develops and operates within shared experiences and connections, enabled by structural possibilities provided by the forums giving users the opportunity and means to interact within public, restricted, and more private spaces, as well as within groups and in one-to-one exchanges. The atmosphere and feeling of both sites and perceived audiences were important facilitators of empathy, with users sharing a perception of virtual communities of caring and supportive people. Our findings are of value to organizations hosting health forums and to health professionals signposting patients to additional sources of support. ©Sarah Hargreaves, Peter A Bath, Suzanne Duffin, Julie Ellis. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 14.06.2018.
Space transportation system biomedical operations support study
NASA Technical Reports Server (NTRS)
White, S. C.
1983-01-01
The shift of the Space Transportation System (STS) flight tests of the orbiter vehicle to the preparation and flight of the payloads is discussed. Part of this change is the transition of the medical and life sciences aspects of the STS flight operations to reflect the new state. The medical operations, the life sciences flight experiments support requirements and the intramural research program expected to be at KSC during the operational flight period of the STS and a future space station are analyzed. The adequacy of available facilities, plans, and resources against these future needs are compared; revisions and/or alternatives where appropriate are proposed.
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2011 CFR
2011-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. ...
Modeling the effects of high-G stress on pilots in a tracking task
NASA Technical Reports Server (NTRS)
Korn, J.; Kleinman, D. L.
1978-01-01
Air-to-air tracking experiments were conducted at the Aerospace Medical Research Laboratories using both fixed and moving base dynamic environment simulators. The obtained data, which includes longitudinal error of a simulated air-to-air tracking task as well as other auxiliary variables, was analyzed using an ensemble averaging method. In conjunction with these experiments, the optimal control model is applied to model a human operator under high-G stress.
NASA Technical Reports Server (NTRS)
Bean, T. A.; Bowhill, S. A.
1973-01-01
Partial-reflection data collected for the eclipse of July 10, 1972 as well as for July 9 and 11, 1972, are analyzed to determine eclipse effects on D-region electron densities. The partial-reflection experiment was set up to collect data using an on-line PDP-15 computer and DECtape storage. The electron-density profiles show good agreement with results from other eclipses. The partial-reflection programs were changed after the eclipse data collection to improve the operation of the partial-reflection system. These changes were mainly due to expanded computer hardware and have simplified the operations of the system considerably.
Fraction eutectic measurements in slowly cooled Pb - 15 wt percent Sn alloys
NASA Technical Reports Server (NTRS)
Studer, Anthony C.; Laxmanan, V.
1988-01-01
A space shuttle experiment employing the General Purpose Furnace in its isothermal mode of operation is currently manifested for flight circa 1989. The aim of this experiment was to investigate the role of gravity in a slowly, and isothermally, cooled sample of a binary Pb - 15 wt percent Sn alloy. Ground based work in support of the microgravity experiment is discussed. In particular, it is shown that fraction eutectic measurements using an image analyzer, can be used to satisfactorily describe macrosegregation occurring in these slowly cooled ingots.
The Regularities of Fatigue Crack Growth in Airframes Elements at Real Operation Conditions
NASA Astrophysics Data System (ADS)
Pavelko, Igors; Pavelko, Vitalijs
The results of analytical and experimental researches concerning predicting of fatigue crack growth in the operating conditions are presented. First of all the main factors causing a fatigue damage initiation and growth are analyzed and divided to two groups. Common conditions of fatigue damage precise predicting are established. The problem of fatigue crack growth at the stresses of variable amplitude was analyzed and an approach of description of this process is performed. Two examples present the efficiency of this approach. Theory of fatigue crack growth indication and the crack growth indicator (CGI) are developed. There is planned and executed a flight experiment using CGI located on two aircraft An-24 and An-26. Results of crack growth in CGI at operational load allowed to evaluate the parameters of generalized Paris-Erdogan law and statistical properties of crack increment per flight.
Design and Construction of Simple, Nitrogen-Laser-Pumped, Tunable Dye Lasers
ERIC Educational Resources Information Center
Hilborn, Robert C.
1978-01-01
The basic physical principles of dye lasers are discussed and used to analyze the design and operation of tunable dye lasers pumped by pulsed nitrogen lasers. Details of the design and construction of these dye lasers are presented. Some simple demonstration experiments are described. (BB)
Interdisciplinary Graduate Studies in Brazil: Lessons from Sustainability and Environmental Sciences
ERIC Educational Resources Information Center
Bursztyn, Marcel; Maury, María Beatriz; Litre, Gabriela
2016-01-01
This article analyzes the process of institutionalizing interdisciplinary graduate programs in Brazil, which has over more than four decades of experience implementing masters and doctoral problem-oriented programs designed to operate outside the disciplinary structure of universities. Brazil has a high degree of centrality and government…
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
10 CFR 39.13 - Specific licenses for well logging.
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicant will use to demonstrate the logging supervisor's knowledge and understanding of and ability to... and understanding of and ability to comply with the applicant's operating and emergency procedures. (c... performing the analysis; and (3) Pertinent experience of the person who will analyze the wipe samples. [52 FR...
[The prevalence and influencing factors of eye diseases for IT industry video operation workers].
Zhao, Liang-liang; Yu, Yan-yan; Yu, Wen-lan; Xu, Ming; Cao, Wen-dong; Zhang, Hong-bing; Han, Lei; Zhang, Heng-dong
2013-05-01
To investigate the situation of video-contact and eye diseases for IT industry video operation workers, and to analyze the influencing factors, providing scientific evidence for the make of health-strategy for IT industry video operation workers. We take the random cluster sampling method to choose 190 IT industry video operation workers in a city of Jiangsu province, analyzing the relations between video contact and eye diseases. The daily video contact time of IT industry video operation workers is 6.0-16.0 hours, whose mean value is (I 0.1 ± 1.8) hours. 79.5% of workers in this survey wear myopic lens, 35.8% of workers have a rest during their working, and 14.2% of IT workers use protective products when they feel unwell of their eyes. Following the BUT experiment, 54.7% of IT workers have the normal examine results of hinoculus, while 45.3% have the abnormal results of at least one eye. Simultaneously, 54.7% workers have the normal examine results of hinoculus in the SIT experiment, however, 42.1% workers are abnormal. According to the broad linear model, there are six influencing factors (daily mean time to video, distance between eye and displayer, the frequency of rest, whether to use protective products when they feel unwell of their eyes, the type of dis player and daily time watching TV.) have significant influence on vision, having statistical significance. At the same time, there are also six influencing factors (whether have a rest regularly,sex, the situation of diaphaneity for cornea, the shape of pupil, family history and whether to use protective products when they feel unwell of their eyes.) have significant influence on the results of BUT experiment,having statistical significance. However, there are seven influencing factors (the type of computer, sex, the shape of pupil, the situation of diaphaneity for cornea, the angle between displayer and workers' sight, the type of displayer and the height of operating floor.) have significant influence on the results of SIT experiment,having statistical significance. The health-situation of IT industry video operation workers' eye is not optimistic, most of workers are lack of protection awareness; we need to strengthen propaganda and education according to its influencing factors and to improve the level of medical control and prevention for eye diseases in relevant industries.
Proceedings of Technical Sessions, Volumes 1 and 2: the LACIE Symposium
NASA Technical Reports Server (NTRS)
1979-01-01
The technical design of the Large Area Crop Inventory Experiment is examined and data acquired over 3 global crop years is analyzed with respect to (1) sampling and aggregation; (2) growth size estimation; (3) classification and mensuration; (4) yield estimation; and (5) accuracy assessment. Seventy-nine papers delivered at conference sessions cover system implementation and operation; data processing systems; experiment results and accuracy; supporting research and technology; and the USDA application test system.
Laser anemometry for hot flows
NASA Astrophysics Data System (ADS)
Kugler, P.; Langer, G.
1987-07-01
The fundamental principles, instrumentation, and practical operation of LDA and laser-transit-anemometry systems for measuring velocity profiles and the degree of turbulence in high-temperature flows are reviewed and illustrated with diagrams, drawings and graphs of typical data. Consideration is given to counter, tracker, spectrum-analyzer and correlation methods of LDA signal processing; multichannel analyzer and cross correlation methods for LTA data; LTA results for a small liquid fuel rocket motor; and experiments demonstrating the feasibility of an optoacoustic demodulation scheme for LDA signals from unsteady flows.
Control and Signal Conditioning Circuits for E.I.R.M.A (Energetic Ion Retarding Mass Analyzer),
1984-10-01
electrically isolated segment of the vehicle with respect to the main body of the vehicle containing the mass analyzer and other instruments. The...ambient plasma. The vehicle was to be charged positive by the ejection of electrons and negative by the positive ion ejection. Also, the operation of...ambient ions and the ener- getic ions emitted and created during the vehicle charging and dis- charging experiments. It also was intended to survey the
Historical data and analysis for the first five years of KSC STS payload processing
NASA Technical Reports Server (NTRS)
Ragusa, J. M.
1986-01-01
General and specific quantitative and qualitative results were identified from a study of actual operational experience while processing 186 science, applications, and commercial payloads for the first 5 years of Space Transportation System (STS) operations at the National Aeronautics and Space Administration's (NASA) John F. Kennedy Space Center (KSC). All non-Department of Defense payloads from STS-2 through STS-33 were part of the study. Historical data and cumulative program experiences from key personnel were used extensively. Emphasis was placed on various program planning and events that affected KSC processing, payload experiences and improvements, payload hardware condition after arrival, services to customers, and the impact of STS operations and delays. From these initial considerations, operational drivers were identified, data for selected processing parameters collected and analyzed, processing criteria and options determined, and STS payload results and conclusions reached. The study showed a significant reduction in time and effort needed by STS customers and KSC to process a wide variety of payload configurations. Also of significance is the fact that even the simplest payloads required more processing resources than were initially assumed. The success to date of payload integration, testing, and mission operations, however, indicates the soundness of the approach taken and the methods used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagen, E.W.
This report reviews and evaluates the performance of the compressed-air and pressurized-nitrogen gas systems in commercial nuclear power units. The information was collected from readily available operating experiences, licensee event reports, system designs in safety analysis reports, and regulatory documents. The results are collated and analyzed for significance and impact on power plant safety performance. Under certain circumstances, the fail-safe philosophy for a piece of equipment or subsystem of the compressed-air systems initiated a series of actions culminating in reactor transient or unit scram. However, based on this study of prevailing operating experiences, reclassifying the compressed-gas systems to a highermore » safety level will neither prevent (nor mitigate) the reoccurrences of such happenings nor alleviate nuclear power plant problems caused by inadequate maintenance, operating procedures, and/or practices. Conversely, because most of the problems were derived from the sources listed previously, upgrading of both maintenance and operating procedures will not only result in substantial improvement in the performance and availability of the compressed-air (and backup nitrogen) systems but in improved overall plant performance.« less
A rocket-borne electrostatic analyzer for measurement of energetic particle flux
NASA Technical Reports Server (NTRS)
Pozzi, M. A.; Smith, L. G.; Voss, H. D.
1979-01-01
A rocket-borne electrostatic analyzer experiment is described. It is used to measure energetic particle flux (0.9 to 14 keV) in the nighttime midlatitude E region. Energetic particle precipitation is believed to be a significant nighttime ionization source, particularly during times of high geomagnetic activity. The experiment was designed for use in the payload of a Nike Apache sounding rocket. The electrostatic analyzer employs two cylindrical parallel plates subtending a central angle of 90 deg. The voltage waveform supplied to the plates is a series of steps synchronized to the spin of the payload during flight. Both positive and negative voltages are provided, extending the detection capabilities of the instrument to both electrons and protons (and positive ions). The development, construction and operation of the instrument is described together with a preliminary evaluation of its performance in a rocket flight.
DC breakdown characteristics of silicone polymer composites for HVDC insulator applications
NASA Astrophysics Data System (ADS)
Han, Byung-Jo; Seo, In-Jin; Seong, Jae-Kyu; Hwang, Young-Ho; Yang, Hai-Won
2015-11-01
Critical components for HVDC transmission systems are polymer insulators, which have stricter requirements that are more difficult to achieve compared to those of HVAC insulators. In this study, we investigated the optimal design of HVDC polymer insulators by using a DC electric field analysis and experiments. The physical properties of the polymer specimens were analyzed to develop an optimal HVDC polymer material, and four polymer specimens were prepared for DC breakdown experiments. Single and reverse polarity breakdown tests were conducted to analyze the effect of temperature on the breakdown strength of the polymer. In addition, electric fields were analyzed via simulations, in which a small-scale polymer insulator model was applied to prevent dielectric breakdown due to electric field concentration, with four DC operating conditions taken into consideration. The experimental results show that the electrical breakdown strength and the electric field distribution exhibit significant differences in relation to different DC polarity transition procedures.
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin
2011-01-01
The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.
NASA Astrophysics Data System (ADS)
Groemer, Gernot; Losiak, Anna; Soucek, Alexander; Plank, Clemens; Zanardini, Laura; Sejkora, Nina; Sams, Sebastian
2016-12-01
We report on the AMADEE-15 mission, a 12-day Mars analog field test at the Kaunertal Glacier in Austria. Eleven experiments were conducted by a field crew at the test site under simulated martian surface exploration conditions and coordinated by a Mission Support Center in Innsbruck, Austria. The experiments' research fields encompassed geology, human factors, astrobiology, robotics, tele-science, exploration, and operations research. A Remote Science Support team analyzed field data in near real time, providing planning input for a flight control team to manage a complex system of field assets in a realistic work flow, including: two advanced space suit simulators; and four robotic and aerial vehicles. Field operations were supported by a dedicated flight planning group, an external control center tele-operating the PULI-rover, and a medical team. A 10-min satellite communication delay and other limitations pertinent to human planetary surface activities were introduced. This paper provides an overview of the geological context and environmental conditions of the test site and the mission architecture, with a focus on the mission's communication infrastructure. We report on the operational workflows and the experiments conducted, as well as a novel approach of measuring mission success through the introduction of general analog mission transferrable performance indicators.
1984-01-01
During a Spacelab flight, the hub of activity was the Payload Operations Control Center (POCC) at the Johnson Space Flight Center (JSC) in Houston, Texas. The POCC became home to the management and science teams who worked around the clock to guide and support the mission. All Spacelab principal investigators and their teams of scientists and engineers set up work areas in the POCC. Through the use of computers, they could send commands to their instruments and receive and analyze experiment data. Instantaneous video and audio communications made it possible for scientists on the ground to follow the progress of their research almost as if they were in space with the crew. This real-time interaction between investigators on the ground and the crew in space was probably the most exciting of Spacelab's many capabilities. As principal investigators talked to the payload specialists during the mission, they consulted on experiment operations, made decisions, and shared in the thrill of gaining new knowledge. In December 1990, a newly-established POCC at the Marshall Space Flight Center (MSFC) opened its door for the operations of the Spacelab payloads and experiments, while JSC monitored the Shuttle flight operations. MSFC had managing responsibilities for the Spacelab missions.
Analytical investigation of critical phenomena in MHD power generators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-07-31
Critical phenomena in the Arnold Engineering Development Center (AEDC) High Performance Demonstration Experiment (HPDE) and the US U-25 Experiment, are analyzed. Also analyzed are the performance of a NASA-specified 500 MW(th) flow train and computations concerning critica issues for the scale-up of MHD Generators. The HPDE is characterized by computational simulations of both the nominal conditions and the conditions during the experimental runs. The steady-state performance is discussed along with the Hall voltage overshoots during the start-up and shutdown transients. The results of simulations of the HPDE runs with codes from the Q3D and TRANSIENT code families are compared tomore » the experimental results. The results of the simulations are in good agreement with the experimental data. Additional critica phenomena analyzed in the AEDC/HPDE are the optimal load schedules, parametric variations, the parametric dependence of the electrode voltage drops, the boundary layer behavior, near electrode phenomena with finite electrode segmentation, and current distribution in the end regions. The US U-25 experiment is characterized by computational simulations of the nominal operating conditions. The steady-state performance for the nominal design of the US U-25 experiment is analyzed, as is the dependence of performance on the mass flow rate. A NASA-specified 500 MW(th) MHD flow train is characterized for computer simulation and the electrical, transport, and thermodynamic properties at the inlet plane are analyzed. Issues for the scale-up of MHD power trains are discussed. The AEDC/HPDE performance is analyzed to compare these experimental results to scale-up rules.« less
NASA Technical Reports Server (NTRS)
1974-01-01
An experiment was conducted to measure and map the man-made radio frequency emanations which exist at earth orbital altitudes. The major objectives of the program are to develop a complete conceptual experiment and developmental hardware for the collection and processing of data required to produce meaningful statistics on man-made noise level variations as functions of time, frequency, and geographic location. A wide dispersion measurement receiver mounted in a spacecraft operating in a specialized orbit is used to obtain the data. A summary of the experiment designs goals and constraints is provided. The recommended orbit for the spacecraft is defined. The characteristics of the receiver and the antennas are analyzed.
The Phoretic Motion Experiment (PME) definition phase
NASA Technical Reports Server (NTRS)
Eaton, L. R.; Neste, S. L. (Editor)
1982-01-01
The aerosol generator and the charge flow devices (CFD) chamber which were designed for zero-gravity operation was analyzed. Characteristics of the CFD chamber and aerosol generator which would be useful for cloud physics experimentation in a one-g as well as a zero-g environment are documented. The Collision type of aerosol generator is addressed. Relationships among the various input and output parameters are derived and subsequently used to determine the requirements on the controls of the input parameters to assure a given error budget of an output parameter. The CFD chamber operation in a zero-g environment is assessed utilizing a computer simulation program. Low nuclei critical supersaturation and high experiment accuracies are emphasized which lead to droplet growth times extending into hundreds of seconds. The analysis was extended to assess the performance constraints of the CFD chamber in a one-g environment operating in the horizontal mode.
Analyzing spring pendulum phenomena with a smart-phone acceleration sensor
NASA Astrophysics Data System (ADS)
Kuhn, Jochen; Vogt, Patrik
2012-11-01
This paper describes two further pendulum experiments using the acceleration sensor of a smartphone in this column (for earlier contributions concerning this topic, including the description of the operation and use of the acceleration sensor, see Refs. 1 and 2). In this paper we focus on analyzing spring pendulum phenomena. Therefore two spring pendulum experiments will be described in which a smartphone is used as a pendulum body and SPARKvue3 software is used in conjunction with an iPhone or an iPod touch, or the Accelogger4 app for an Android device.1,2 As described in Ref. 1, the values measured by the smartphone are subsequently exported to a spreadsheet application (e.g., MS Excel) for analysis.
A PILOT CENTER FOR EDUCATIONAL POLICY RESEARCH. FINAL REPORT--PART I.
ERIC Educational Resources Information Center
ADELSON, MARVIN; AND OTHERS
THE PILOT CENTER FOR EDUCATIONAL POLICY RESEARCH, OPERATED BY THE SYSTEM DEVELOPMENT CORPORATION FROM JUNE 1, 1967, THROUGH FEBRUARY 29, 1968, HAD THREE OBJECTIVES--(1) TO INVESTIGATE, ANALYZE, AND EXPERIMENT WITH METHODS, PROCEDURES, AND TOOLS FOR STUDYING THE FUTURE AS IT COULD AFFECT EDUCATION IN THE UNITED STATES, (2) TO FORECAST POSSIBLE…
Commanding the Computer: Functions and Concepts of Videotex Technology for Eighth-Grade Students.
ERIC Educational Resources Information Center
Eastman, Susan T.; Agostino, Donald E.
This study combines quantitative and ethnographic methods to analyze middle-school students' uses and understandings of microcomputers and videotex. As an experiment in teaching library research skills, 27 eighth graders were assigned to search an online encyclopedia in preparation for writing a science theme. The students' operational practices…
Two years of on-orbit gallium arsenide performance from the LIPS solar cell panel experiment
NASA Technical Reports Server (NTRS)
Francis, R. W.; Betz, F. E.
1985-01-01
The LIPS on-orbit performance of the gallium arsenide panel experiment was analyzed from flight operation telemetry data. Algorithms were developed to calculate the daily maximum power and associated solar array parameters by two independent methods. The first technique utilizes a least mean square polynomial fit to the power curve obtained with intensity and temperature corrected currents and voltages; whereas, the second incorporates an empirical expression for fill factor based on an open circuit voltage and the calculated series resistance. Maximum power, fill factor, open circuit voltage, short circuit current and series resistance of the solar cell array are examined as a function of flight time. Trends are analyzed with respect to possible mechanisms which may affect successive periods of output power during 2 years of flight operation. Degradation factors responsible for the on-orbit performance characteristics of gallium arsenide are discussed in relation to the calculated solar cell parameters. Performance trends and the potential degradation mechanisms are correlated with existing laboratory and flight data on both gallium arsenide and silicon solar cells for similar environments.
NASA Technical Reports Server (NTRS)
Cardinali, Carla; Rukhovets, Leonid; Tenenbaum, Joel
2003-01-01
We have utilized an extensive set of independent British Airways flight data recording wind vector and temperature observations (the Global Aircraft Data Set [GADS] archive) in three ways: (a) as an independent check of operational analyses; (b) as an analysis observing system experiment (OSE) as if the GADS observations were available in real time; and (c) as the corresponding forecast simulation experiment applicable to future operational forecasts. Using a 31 day sample (0000 UTC 20 December 2000 through 0000 UTC 20 January 2000) from Winter 2000, we conclude that over the data-dense continental U. S. analyzed jet streaks are too weak by -2% to -5%. Over nearby data-sparse regions of Canada, analyzed jet streaks are too weak by -5% to -9%. The second range provides a limit on the accuracy of current jet streak analyses over the portions of the -85% of the earth's surface that are poorly covered by non-satellite observations. The -5% to -9% range is relevant for the pre-third generation satellite (AIRS, IASI, GIFTS) era.
Variability in Resident Operative Hand Experience by Specialty.
Silvestre, Jason; Lin, Ines C; Levin, L Scott; Chang, Benjamin
2018-01-01
Recent attention has sought to standardize hand surgery training in the United States. This study analyzes the variability in operative hand experience for orthopedic and general surgery residents. Case logs for orthopedic and general surgery residency graduates were obtained from the American Council of Graduate Medical Education (2006-2007 to 2014-2015). Plastic surgery case logs were not available for comparison. Hand surgery case volumes were compared between specialties with parametric tests. Intraspecialty variation in orthopedic surgery was assessed between the bottom and top 10th percentiles in procedure categories. Case logs for 9605 general surgery residents and 5911 orthopedic surgery residents were analyzed. Orthopedic surgery residents performed a greater number of hand surgery cases than general surgery residents ( P < .001). Mean total hand experience ranged from 2.5 ± 4 to 2.8 ± 5 procedures for general surgery residents with no reported cases of soft tissue repairs, vascular repairs, and replants. Significant intraspecialty variation existed in orthopedic surgery for all hand procedure categories (range, 3.3-15.0). As the model for hand surgery training evolves, general surgeons may represent an underutilized talent pool to meet the critical demand for hand surgeon specialists. Future research is needed to determine acceptable levels of training variability in hand surgery.
Results from the Space Shuttle STS-95 Electronic Nose Experiment
NASA Technical Reports Server (NTRS)
Ryan, M. A.; Buehler, M. G.; Homer, M. L.; Mannatt, K. S.; Lau, B.; Jackson, S.; Zhou, H.
2000-01-01
A miniature electronic nose in which the sensing media are insulating polymers loaded with carbon black as a conductive medium has been designed and built at the Jet Propulsion Laboratory. The ENose has a volume of 1700 cc, weighs 1.4 kg including the operating computer, and uses 1.5 W average power (3 W peak power). This ENose was used in a demonstration experiment aboard STS-95 (October, 1998), in which the ENose was operated continuously for six days and recorded the sensors' response to the air in the middeck. The ENose was designed to detect ten common contaminants in space shuttle crew quarters air. The experiment was controlled by collecting air samples daily and analyzing them using standard analytical techniques after the flight. Changes in humidity were detected and quantified, neither the ENose nor the air samples detected any of the contaminants on the target list. The device is microgravity insensitive.
Interdependence of science requirements and safety limitations on the space station
NASA Technical Reports Server (NTRS)
Barber, Patrick G.
1990-01-01
One of the benefits of experimentation on the Space Station is the ability to carry out the experiment, to immediately analyze the results, to calculate improved experimental parameters, and to quickly repeat the experiment. In this improved mode of operation there are new safety considerations that must be addressed in the design stages of both the station and the experiments. Some of the chemical and procedural requirements are shared, and some of the earth-bound storage, dispensing, and disposal techniques that may assist in the development of analogous procedures for the Space Station are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soukhanovskii, V. A.
2017-09-13
A successful high-performance plasma operation with a radiative divertor has been demonstrated on many tokamak devices, however, significant uncertainty remains in accurately modeling detachment thresholds, and in how detachment depends on divertor geometry. Whereas it was originally planned to perform dedicated divertor experiments on the National Spherical Tokamak Upgrade to address critical detachment and divertor geometry questions for this milestone, the experiments were deferred due to technical difficulties. Instead, existing NSTX divertor data was summarized and re-analyzed where applicable, and additional simulations were performed.
Operational present status and reliability analysis of the upgraded EAST cryogenic system
NASA Astrophysics Data System (ADS)
Zhou, Z. W.; Y Zhang, Q.; Lu, X. F.; Hu, L. B.; Zhu, P.
2017-12-01
Since the first commissioning in 2005, the cryogenic system for EAST (Experimental Advanced Superconducting Tokamak) has been cooled down and warmed up for thirteen experimental campaigns. In order to promote the refrigeration efficiencies and reliability, the EAST cryogenic system was upgraded gradually with new helium screw compressors and new dynamic gas bearing helium turbine expanders with eddy current brake to improve the original poor mechanical and operational performance from 2012 to 2015. Then the totally upgraded cryogenic system was put into operation in the eleventh cool-down experiment, and has been operated for the latest several experimental campaigns. The upgraded system has successfully coped with various normal operational modes during cool-down and 4.5 K steady-state operation under pulsed heat load from the tokamak as well as the abnormal fault modes including turbines protection stop. In this paper, the upgraded EAST cryogenic system including its functional analysis and new cryogenic control networks will be presented in detail. Also, its operational present status in the latest cool-down experiments will be presented and the system reliability will be analyzed, which shows a high reliability and low fault rate after upgrade. In the end, some future necessary work to meet the higher reliability requirement for future uninterrupted long-term experimental operation will also be proposed.
NASA Astrophysics Data System (ADS)
Shirley, Rachel Elizabeth
Nuclear power plant (NPP) simulators are proliferating in academic research institutions and national laboratories in response to the availability of affordable, digital simulator platforms. Accompanying the new research facilities is a renewed interest in using data collected in NPP simulators for Human Reliability Analysis (HRA) research. An experiment conducted in The Ohio State University (OSU) NPP Simulator Facility develops data collection methods and analytical tools to improve use of simulator data in HRA. In the pilot experiment, student operators respond to design basis accidents in the OSU NPP Simulator Facility. Thirty-three undergraduate and graduate engineering students participated in the research. Following each accident scenario, student operators completed a survey about perceived simulator biases and watched a video of the scenario. During the video, they periodically recorded their perceived strength of significant Performance Shaping Factors (PSFs) such as Stress. This dissertation reviews three aspects of simulator-based research using the data collected in the OSU NPP Simulator Facility: First, a qualitative comparison of student operator performance to computer simulations of expected operator performance generated by the Information Decision Action Crew (IDAC) HRA method. Areas of comparison include procedure steps, timing of operator actions, and PSFs. Second, development of a quantitative model of the simulator bias introduced by the simulator environment. Two types of bias are defined: Environmental Bias and Motivational Bias. This research examines Motivational Bias--that is, the effect of the simulator environment on an operator's motivations, goals, and priorities. A bias causal map is introduced to model motivational bias interactions in the OSU experiment. Data collected in the OSU NPP Simulator Facility are analyzed using Structural Equation Modeling (SEM). Data include crew characteristics, operator surveys, and time to recognize and diagnose the accident in the scenario. These models estimate how the effects of the scenario conditions are mediated by simulator bias, and demonstrate how to quantify the strength of the simulator bias. Third, development of a quantitative model of subjective PSFs based on objective data (plant parameters, alarms, etc.) and PSF values reported by student operators. The objective PSF model is based on the PSF network in the IDAC HRA method. The final model is a mixed effects Bayesian hierarchical linear regression model. The subjective PSF model includes three factors: The Environmental PSF, the simulator Bias, and the Context. The Environmental Bias is mediated by an operator sensitivity coefficient that captures the variation in operator reactions to plant conditions. The data collected in the pilot experiments are not expected to reflect professional NPP operator performance, because the students are still novice operators. However, the models used in this research and the methods developed to analyze them demonstrate how to consider simulator bias in experiment design and how to use simulator data to enhance the technical basis of a complex HRA method. The contributions of the research include a framework for discussing simulator bias, a quantitative method for estimating simulator bias, a method for obtaining operator-reported PSF values, and a quantitative method for incorporating the variability in operator perception into PSF models. The research demonstrates applications of Structural Equation Modeling and hierarchical Bayesian linear regression models in HRA. Finally, the research demonstrates the benefits of using student operators as a test platform for HRA research.
NASA Astrophysics Data System (ADS)
Kuo, Y.-H.; Leung, J. M. Y.; Graham, C. A.
2015-05-01
In this paper, we present a case study of modelling and analyzing the patient flow of a hospital emergency department in Hong Kong. The emergency department is facing the challenge of overcrowding and the patients there usually experience a long waiting time. Our project team was requested by a senior consultant of the emergency department to analyze the patient flow and provide a decision support tool to help improve their operations. We adopt a simulation approach to mimic their daily operations. With the simulation model, we conduct a computational study to examine the effect of physician heterogeneity on the emergency department performance. We found that physician heterogeneity has a great impact on the operational efficiency and thus should be considered when developing simulation models. Our computational results show that, with the same average of service rates among the physicians, variation in the rates can improve overcrowding situation. This suggests that emergency departments may consider having some efficient physicians to speed up the overall service rate in return for more time for patients who need extra medical care.
What Can Happen When Business and Language Faculty Cooperate across an Ocean?
ERIC Educational Resources Information Center
Bryant, Michael; Karney, Dennis; Vigier, Mary
2010-01-01
Management schools are expected to educate future professionals with the necessary skills to operate successfully in a global business environment. In this paper, the authors analyze and reflect on an experiment in interdisciplinary cooperation undertaken by business faculty at a US university and language faculty at a French School of Management.…
Culture and Character Education in a Jewish Day School: A Case Study of Life and Experience
ERIC Educational Resources Information Center
Roso, Calvin G.
2013-01-01
This article addresses how to teach character comprehensively by studying ways a school's concurrent curricula (the official curriculum, the operational curriculum, the extra curriculum, and the hidden curriculum) can be used to teach character to students. A single case study analyzes the curriculum at a Jewish day school by examining school…
NASA Technical Reports Server (NTRS)
1983-01-01
The development and systems architectural requirements of the space station program are described. The system design is determined by user requirements. Investigated topics include physical and life science experiments, commercial utilization, U.S. national security, and remote space operations. The economic impact of the space station program is analyzed.
ERIC Educational Resources Information Center
Woodward, Jerry
2016-01-01
This study examined how a child constructed a scheme (abbreviated QRE) for producing mathematical equivalence via operations on composite units between two multiplicative situations consisting of singletons and composite units. Within the context of a teaching experiment, the work of one child, Joe, was analyzed over the course of 14 teaching…
Apollo experience report: Crew station integration. Volume 4: Stowage and the support team concept
NASA Technical Reports Server (NTRS)
Hix, M. W.
1973-01-01
Crew equipment stowage and stowage arrangement in spacecraft are discussed. Configuration control in order to maximize crew equipment operational performance, stowage density, and available stowage volume are analyzed. The NASA crew equipment stowage control process requires a support team concept to coordinate the integration of crew equipment into the spacecraft.
Knowledge Networking: A Dilemma in Building Social Capital through Nonformal Education
ERIC Educational Resources Information Center
Shrestha, Mona; Wilson, Steve; Singh, Michael
2008-01-01
This article reports the results of an inquiry into the embeddedness of nonformal education (NFE) in the work of knowledge service providers, analyzing the dilemmas they experience in their operations around a public housing precinct. It explores the proposition that the networking of NFE providers is a mechanism by which a fragmented community…
Integrated human-machine intelligence in space systems.
Boy, G A
1992-07-01
This paper presents an artificial intelligence approach to integrated human-machine intelligence in space systems. It discusses the motivations for Intelligent Assistant Systems in both nominal and abnormal situations. The problem of constructing procedures is shown to be a very critical issue. In particular, keeping procedural experience in both design and operation is critical. We suggest what artificial intelligence can offer in this direction. Some crucial problems induced by this approach are discussed in detail. Finally, we analyze the various roles that would be shared by both astronauts, ground operators, and the intelligent assistant system.
Development of a low energy electron spectrometer for SCOPE
NASA Astrophysics Data System (ADS)
Tominaga, Y.; Saito, Y.; Yokota, S.
2010-12-01
We are newly developing an electrostatic analyzer which measures low energy electrons for the future satellite mission SCOPE (cross Scale COupling in the Plasma universE). The main purpose of the SCOPE mission is to understand the cross scale coupling between macroscopic MHD scale phenom- ena and microscopic ion and electron scale phenomena. In order to understand the dynamics of plasma in such small scales, we need to observe the plasma with an analyzer which has high time resolutions. In the Earth's magnetosphere, typical timescale of plasma cyclotron frequency is ~10 sec (ions) and ~ 10 msec (electrons). In order to conduct electron-scale observations, an analyzer which has a very high time resolution(~ 10 msec) is necessary for the experiment. So far, we decided a design of the analyzer. The analyzer has three nested spherical/toroidal deflectors, which enables us to measure two different energies simultaneously and shorten the time resolution of the experiment. In order to obtain 3D velocity distribution functions of electrons, the analyzer must have 4-pi steradian field of view. We will install 8 sets of the analyzers on the satellite. Using all these analyzers we will secure 4-pi str fov at the same time. In the experiment, we plan to measure electrons from 10 eV to 22.5 keV with 32 steps. Given that the sampling time of the experiment is 0.5 msec, it takes about 8 msec to measure the whole energy range, then the time resolution of the experiment is 8 msec. The energy and angular resolution of the inner analyzer is 0.23 and 16 degrees, respectively, and that of the outer analyzer is 0.17 and 11.5 degrees, respectively. To measure enough electrons within the sampling time, the analyzer is designed to have geometrical factors (sensitivities) of 7.5e-3 (inner analyzer) and 1.0e-2 (outer analyzer) cm-2 str-1, respectively. However, it is not apparent that these characteristics of the analyzer is really appropriate for the experiment. And there are some operational problems which we have to consider and resolve. In this study, we ... 1.confirm that the analyzer we designed has characteristics appropriate for the experiment and it can measure the 3D distribution function and velocity moments of electrons. 2.estimate how the non-uniformity of the analyzer's efficiency affects the velocity moments. 3.estimate how spin motion of the satellite affects the velocity moments. Assuming Maxwellian electron distribution function with known density, bulk velocity, and temperature, we calculated the counts that the analyzer will measure taking into account the characteristic of the analyzer. Using these counts, we calculated the distribution function and velocity moments, and compared the results with the assumed density, bulk velocity and temperature in order to see the precision of the experiment. From these calculations we found that ... 1.the characteristics of the analyzer are good enough to measure the velocity moments of electrons with an error less than several percent. 2.the non-uniformity of the efficiency of the analyzers will severely affect the bulk velocity of electrons. 3.we should have special observation modes (to change the time resolution or energy range) which depends on the observation area.
The MARS2013 Mars analog mission.
Groemer, Gernot; Soucek, Alexander; Frischauf, Norbert; Stumptner, Willibald; Ragonig, Christoph; Sams, Sebastian; Bartenstein, Thomas; Häuplik-Meusburger, Sandra; Petrova, Polina; Evetts, Simon; Sivenesan, Chan; Bothe, Claudia; Boyd, Andrea; Dinkelaker, Aline; Dissertori, Markus; Fasching, David; Fischer, Monika; Föger, Daniel; Foresta, Luca; Fritsch, Lukas; Fuchs, Harald; Gautsch, Christoph; Gerard, Stephan; Goetzloff, Linda; Gołebiowska, Izabella; Gorur, Paavan; Groemer, Gerhard; Groll, Petra; Haider, Christian; Haider, Olivia; Hauth, Eva; Hauth, Stefan; Hettrich, Sebastian; Jais, Wolfgang; Jones, Natalie; Taj-Eddine, Kamal; Karl, Alexander; Kauerhoff, Tilo; Khan, Muhammad Shadab; Kjeldsen, Andreas; Klauck, Jan; Losiak, Anna; Luger, Markus; Luger, Thomas; Luger, Ulrich; McArthur, Jane; Moser, Linda; Neuner, Julia; Orgel, Csilla; Ori, Gian Gabriele; Paternesi, Roberta; Peschier, Jarno; Pfeil, Isabella; Prock, Silvia; Radinger, Josef; Ramirez, Barbara; Ramo, Wissam; Rampey, Mike; Sams, Arnold; Sams, Elisabeth; Sandu, Oana; Sans, Alejandra; Sansone, Petra; Scheer, Daniela; Schildhammer, Daniel; Scornet, Quentin; Sejkora, Nina; Stadler, Andrea; Stummer, Florian; Taraba, Michael; Tlustos, Reinhard; Toferer, Ernst; Turetschek, Thomas; Winter, Egon; Zanella-Kux, Katja
2014-05-01
We report on the MARS2013 mission, a 4-week Mars analog field test in the northern Sahara. Nineteen experiments were conducted by a field crew in Morocco under simulated martian surface exploration conditions, supervised by a Mission Support Center in Innsbruck, Austria. A Remote Science Support team analyzed field data in near real time, providing planning input for the management of a complex system of field assets; two advanced space suit simulators, four robotic vehicles, an emergency shelter, and a stationary sensor platform in a realistic work flow were coordinated by a Flight Control Team. A dedicated flight planning group, external control centers for rover tele-operations, and a biomedical monitoring team supported the field operations. A 10 min satellite communication delay and other limitations pertinent to human planetary surface activities were introduced. The fields of research for the experiments were geology, human factors, astrobiology, robotics, tele-science, exploration, and operations research. This paper provides an overview of the geological context and environmental conditions of the test site and the mission architecture, in particular the communication infrastructure emulating the signal travel time between Earth and Mars. We report on the operational work flows and the experiments conducted, including a deployable shelter prototype for multiple-day extravehicular activities and contingency situations.
Centrifuge advances using HTS magnetic bearings
NASA Astrophysics Data System (ADS)
Werfel, F. N.; Flögel-Delor, U.; Rothfeld, R.; Wippich, D.; Riedel, T.
2001-05-01
Passive magnetic bearings are of increasing technical interest. We performed experiments with centrifugal rotors to analyze gyroscopic forces in terms imbalance, rotor elasticity and damping. Centrifuge rotors need to be operated soft and stable without whirling the sediments. In order to evaluate optimal parameters critical and resonance behaviors are investigated. Eccentricities up 2 mm are safely passed by accelerating test wheels. In a simple model we describe the effect of passing critical rotational speeds. Measurements of bearing properties and wheel performance are presented. We have constructed a first prototype centrifuge designed with a HTS double bearing which operates a titanium rotor safely up to 30 000 rpm. A 15 W Stirling cooler serves cryogenics of the YBCO stators. From the experiments design guidelines for centrifugal applications with HTS bearings are given.
Tracker: Image-Processing and Object-Tracking System Developed
NASA Technical Reports Server (NTRS)
Klimek, Robert B.; Wright, Theodore W.
1999-01-01
Tracker is an object-tracking and image-processing program designed and developed at the NASA Lewis Research Center to help with the analysis of images generated by microgravity combustion and fluid physics experiments. Experiments are often recorded on film or videotape for analysis later. Tracker automates the process of examining each frame of the recorded experiment, performing image-processing operations to bring out the desired detail, and recording the positions of the objects of interest. It can load sequences of images from disk files or acquire images (via a frame grabber) from film transports, videotape, laser disks, or a live camera. Tracker controls the image source to automatically advance to the next frame. It can employ a large array of image-processing operations to enhance the detail of the acquired images and can analyze an arbitrarily large number of objects simultaneously. Several different tracking algorithms are available, including conventional threshold and correlation-based techniques, and more esoteric procedures such as "snake" tracking and automated recognition of character data in the image. The Tracker software was written to be operated by researchers, thus every attempt was made to make the software as user friendly and self-explanatory as possible. Tracker is used by most of the microgravity combustion and fluid physics experiments performed by Lewis, and by visiting researchers. This includes experiments performed on the space shuttles, Mir, sounding rockets, zero-g research airplanes, drop towers, and ground-based laboratories. This software automates the analysis of the flame or liquid s physical parameters such as position, velocity, acceleration, size, shape, intensity characteristics, color, and centroid, as well as a number of other measurements. It can perform these operations on multiple objects simultaneously. Another key feature of Tracker is that it performs optical character recognition (OCR). This feature is useful in extracting numerical instrumentation data that are embedded in images. All the results are saved in files for further data reduction and graphing. There are currently three Tracking Systems (workstations) operating near the laboratories and offices of Lewis Microgravity Science Division researchers. These systems are used independently by students, scientists, and university-based principal investigators. The researchers bring their tapes or films to the workstation and perform the tracking analysis. The resultant data files generated by the tracking process can then be analyzed on the spot, although most of the time researchers prefer to transfer them via the network to their offices for further analysis or plotting. In addition, many researchers have installed Tracker on computers in their office for desktop analysis of digital image sequences, which can be digitized by the Tracking System or some other means. Tracker has not only provided a capability to efficiently and automatically analyze large volumes of data, saving many hours of tedious work, but has also provided new capabilities to extract valuable information and phenomena that was heretofore undetected and unexploited.
Satellite-aided mobile communications limited operational test in the trucking industry
NASA Technical Reports Server (NTRS)
Anderson, R. E.; Frey, R. L.; Lewis, J. R.
1980-01-01
An experiment with NASA's ATS-6 satellite, that demonstrates the practicality of satellite-aided land mobile communications is described. Satellite communications equipment for the experiment was designed so that it would be no more expensive, when mass produced, than conventional two-way mobile radio equipment. It embodied the operational features and convenience of present day mobile radios. Vehicle antennas 75 cm tall and 2 cm in diameter provided good commercial quality signals to and from trucks and jeeps. Operational applicability and usage data were gathered by installing the radio equipment in five long-haul tractor-trailer trucks and two Air Force search and rescue jeeps. Channel occupancy rates are reported. Air Force personnel found the satellite radio system extremely valuable in their search and rescue mission during maneuvers and actual rescue operations. Propagation data is subjectively analyzed and over 4 hours of random data is categorized and graded as to signal quality on a second by second basis. Trends in different topographic regions are reported. An overall communications reliability of 93% was observed despite low satellite elevation angles ranging from 9 to 24 degrees.
Lewis, Debra A; Ding, Yong Hong; Dai, Daying; Kadirvel, Ramanathan; Danielson, Mark A; Cloft, Harry J; Kallmes, David F
2008-01-01
Background and Purpose Elastase-induced aneurysms in rabbits have been proposed as a useful preclinical tool for device development. The object of this study is to report rates of morbidity and mortality associated with creation and embolization of the elastase-induced rabbit aneurysm, and to assess the impact of operator experience on these rates. Methods Elastase-induced model aneurysms were created in New Zealand White rabbits (n=700). One neuroradiologist/investigator, naïve to the aneurysm creation procedure at the outset of the experiments, performed all surgeries. All morbidity and deaths related to aneurysm creation (n=700) and embolization procedures (n=529) were categorized into acute and chronic deaths. Data were analyzed with single regression analysis and ANOVA. To assess the impact of increasing operator experience, the number of animals was broken into 50 animal increments. Results There were 121 (17%) deaths among 700 subjects. Among 700 aneurysm creation procedures, 59 deaths (8.4%) were noted. Among 529 aneurysm embolization procedures, 43 deaths (8.1%) were noted. Nineteen additional deaths (2.7% of 700 subjects) were unrelated to procedures. Simple regression indicated mortality associated with procedures diminished with increasing operator experience (R2=0.38; p=0.0180) and that for each 50 rabbit increment mortality is reduced on average by 0.6 percent. Conclusions Mortality rates of approximately 8% are associated with both experimental aneurysm creation and with embolization in the rabbit, elastase-induced aneurysm model. Increasing operator experience is inversely correlated with mortality and the age of the rabbit is positively associated with morbidity. PMID:19001536
Video-Assisted Thoracic Surgical Lobectomy for Lung Cancer: Description of a Learning Curve.
Yao, Fei; Wang, Jian; Yao, Ju; Hang, Fangrong; Cao, Shiqi; Cao, Yongke
2017-07-01
Video-assisted thoracic surgical (VATS) lobectomy is gaining popularity in the treatment of lung cancer. The aim of this study is to investigate the learning curve of VATS lobectomy by using multidimensional methods and to compare the learning curve groups with respect to perioperative clinical outcomes. We retrospectively reviewed a prospective database to identify 67 consecutive patients who underwent VATS lobectomy for lung cancer by a single surgeon. The learning curve was analyzed by using moving average and the cumulative sum (CUSUM) method. With the moving average and CUSUM analyses for the operation time, patients were stratified into two groups, with chronological order defining early and late experiences. Perioperative clinical outcomes were compared between the two learning curve groups. According to the moving average method, the peak point for operation time occurred at the 26th case. The CUSUM method also showed the operation time peak point at the 26th case. When results were compared between early- and late-experience periods, the operation time, duration of chest drainage, and postoperative hospital stay were significantly longer in the early-experience group (cases 1 to 26). The intraoperative estimated blood loss was significantly less in the late-experience group (cases 27 to 67). CUSUM charts showed a decreasing duration of chest drainage after the 36th case and shortening postoperative hospital stay after the 37th case. Multidimensional statistical analyses suggested that the learning curve for VATS lobectomy for lung cancer required ∼26 cases. Favorable intraoperative and postoperative care parameters for VATS lobectomy were observed in the late-experience group.
Research on bidding quotation game of international project
NASA Astrophysics Data System (ADS)
Lin, Tao; Xu, Xin
2017-04-01
Bidding competition of international projects is more and more fierce currently. However, China started late relatively in the field, it is still lack of experience in the aspect of participation in bidding of international projects, and more effective bidding quotation system is not formed till present. Therefore, China can not win through systemic bidding quotation methods compared with many powerful bidding enterprises in the international field. Research on the field is also focused by many aspects as a result. It is urgent to solve related problems. Game theory is combined for analyzing the effectiveness and operability of bidding quotation models mainly based on current situation of bidding market in China international projects during research process in the paper. The research starts with the perspective of bidders for analyzing their game with tenderers and other bidders. The results have operational value aiming at bidders.
Fatigue Lifespan of Engine Box Influenced by Fan Blade Out
NASA Astrophysics Data System (ADS)
Qiu, Ju; Shi, Jingwei; Su, Huaizhong; Zhang, Jinling; Feng, Juan; Shi, Qian; Tian, Xiaoyu
2017-11-01
This provides precious experience and reliable reference data for future design. This paper introduces the analysis process of Fan-blade-out, and considers the effect of windmill load on the fatigue lifespan of the case. According to Extended Operations (ETOPS) in the airworthiness regulations, the fatigue crack of it is analyzed by the unbalanced rotor load, during FBO. Compared with the lifespan in normal work of the engine, this research provides valuable design experience and reliable reference data for the case design in the near future.
A study experiment of auto idle application in the excavator engine performance
NASA Astrophysics Data System (ADS)
Purwanto, Wawan; Maksum, Hasan; Putra, Dwi Sudarno; Azmi, Meri; Wahyudi, Retno
2016-03-01
The purpose of this study was to analyze the effect of applying auto idle to excavator engine performance, such as machine unitization and fuel consumption in Excavator. Steps to be done are to modify the system JA 44 and 67 in Vehicle Electronic Control Unit (V-ECU). The modifications will be obtained from the pattern of the engine speed. If the excavator attachment is not operated, the engine speed will return to the idle speed automatically. From the experiment results the auto idle reduces fuel consumption in excavator engine.
A study experiment of auto idle application in the excavator engine performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Purwanto, Wawan, E-mail: wawan5527@gmail.com; Maksum, Hasan; Putra, Dwi Sudarno, E-mail: dwisudarnoputra@ft.unp.ac.id
2016-03-29
The purpose of this study was to analyze the effect of applying auto idle to excavator engine performance, such as machine unitization and fuel consumption in Excavator. Steps to be done are to modify the system JA 44 and 67 in Vehicle Electronic Control Unit (V-ECU). The modifications will be obtained from the pattern of the engine speed. If the excavator attachment is not operated, the engine speed will return to the idle speed automatically. From the experiment results the auto idle reduces fuel consumption in excavator engine.
NASA Astrophysics Data System (ADS)
Yang, Qingchun; Chetehouna, Khaled; Gascoin, Nicolas; Bao, Wen
2016-05-01
To enable the scramjet operate in a wider flight Mach number, a staged-combustor with dual-strut is introduced to hold more heat release at low flight Mach conditions. The behavior of mode transition was examined using a direct-connect model scramjet experiment along with pressure measurements. The typical operating modes of the staged-combustor are analyzed. Fuel injection scheme has a significant effect on the combustor operating modes, particularly for the supersonic combustion mode. Thrust performances of the combustor with different combustion modes and fuel distributions are reported in this paper. The first-staged strut injection has a better engine performance in the operation of subsonic combustion mode. On the contrast, the second-staged strut injection has a better engine performance in the operation of supersonic combustion mode.
Dobrinja, C; Trevisan, G; Liguori, G
2009-02-01
The aim of this study is to analyze our preliminary results from minimally invasive video-assisted parathyroidectomy (MIVAP) and demonstrate the feasibility of MIVAP also in non-referral centers. During a period from June 2005 to January 2008, in the General Surgery Department of University of Trieste, we operated on 39 patients with primary hyperparathyroidism (pHPT). MIVAP by an anterior approach was proposed for 23 (59%) patients with sporadic pHPT and one unequivocally enlarged parathyroid gland on pre-operative ultrasound and 99mTc-SestaMIBI scintigraphy without associated goiter and without previous neck surgery. Intra-operatively, a quick parathyroid assay was used during the last 11 surgical procedures. All patients underwent pre-operative and post-operative investigations of calcemia, phoshoremia and PTH levels and vocal cord function. Age, operative times, pathologic findings, post-operative pain, calcemia, length of hospital stay, cosmetic results, and complications were retrospectively analyzed. MIVAP was successfully accomplished in 22 cases. Conversion to standard cervicotomy was required in one patient (4.34%). Mean operative time was 67 min. Post-operative complications included 1 (4.34%) transient hypocalcemia. No laryngeal nerve palsies, no definitive hypocalcemias, no persistent pHPT and no recurrent pHPT were observed. The cosmetic result was excellent in all cases. Our preliminary results demonstrate that MIVAP for localized single-gland adenoma, after adequate training, seems to be feasible with significant advantages, especially in terms of cosmetic results, post-operative pain, and post-operative recovery even in a General Surgery Department, if performed by a dedicated team, with a sufficient and specific activity volume.
Measurements of the STS orbiter's angular stability during in-orbit operations
NASA Technical Reports Server (NTRS)
Neupert, Werner M.; Epstein, Gabriel L.; Houston, James; Zarechnak, Andrew
1995-01-01
We report on measurements of the angular stability, commonly called 'jitter', of the STS Orbiter during normal operations in space. Measurements were carried out by measuring optically the Orbiter's roll and pitch orientation relative to the solar vector as the orbiter was held in a -Z(sub 0) solar inertial orientation (orbiter bay oriented toward the Sun). We also report observations of an interesting perturbation to the orbiter's orientation noted by the crew during the STS-60 mission. These data may be useful in analyzing the in-orbit response of the Orbiter to thruster firings and other applied torques, and may aid in the planning of future experiments that require fine-pointed operations by the orbiter.
Saraee, Amir; Vahedian-Ardakani, Jalal; Saraee, Ehsan; Pakzad, Roshanak; Wadji, Massoud Baghai
2015-03-11
Pancreatic cancer is generally found in the older population Pancreaticoduodenectomy seems to be the only way in resolving these resectable tumors. Allen. O Whipple was the first to describe pancreaticoduodenectomy in 1935 as a modified procedure. This article is a case series with respect to the 7-year experience of the Whipple procedure in Firoozgar Teaching Hospital. Patient surgery details were gathered from the surgical records of the operating room and their clinical records from the hospital archives. Data was analyzed with SPSS software (version 16.0.1). Those patients, whose tumor had invaded the superior mesenteric artery, had extensive portal vein involvement or distant metastasis was considered as unresectable. The first Whipple procedure was recorded in our hospital in 2008. From 2008 till 20 March 2014, 70 cases were collected and analyzed. The mean age of cases was 58.4 years, the mean hospital stay length was 12.9 days (±6.23 days), mean operation time was 376 min (±37.3 min),. The most common presenting symptom was jaundice (78.6 %). Delayed gastric emptying was the most common post-operative complication. The most prevalent cause of reoperation was intra-abdominal abscess. Major morbidities of these patients consisted of cardiac arrhythmias (21.4%) and pneumonia (10%). Minor complications were wound infection (17.1%) and delayed gastric emptying (32.9%). The statistics revealed pancreatic anastomosis failure as 2.9% and a decrease in mortality rate from 50% during the first years of this study to 16% to 20% during the last years. In this case series, the time of operation decreased during the recent years .Analysis shows a correlation between operation time and pack cell transfused during the operation, but no correlation was found between operation time and post-operation hospitalization course. It is true that hospital setting, socioeconomic level of the patients including their compliance, and the expertise of the surgeons and surgical staff can have an influence on the result of this operation, but it seems that the magnitude of the surgical stress of this procedure and the (compromised) functional reserve of this patient population can be a notable factor influencing the outcome.
A Question of Priorities: A Critical Investigation of the McKinney-Vento Act
ERIC Educational Resources Information Center
Cunningham, Keith Alan
2014-01-01
This critical policy ethnography analyzes the McKinney-Vento Act and how the policy is put into practice at a school district within Central Texas. Data comes from conversations with educators occupying key roles within the McKinney-Vento operational bureaucracy at the school district and the researcher's experience as an educator and volunteer at…
The High Definition Earth Viewing (HDEV) Payload
NASA Technical Reports Server (NTRS)
Muri, Paul; Runco, Susan; Fontanot, Carlos; Getteau, Chris
2017-01-01
The High Definition Earth Viewing (HDEV) payload enables long-term experimentation of four, commercial-of-the-shelf (COTS) high definition video, cameras mounted on the exterior of the International Space Station. The payload enables testing of cameras in the space environment. The HDEV cameras transmit imagery continuously to an encoder that then sends the video signal via Ethernet through the space station for downlink. The encoder, cameras, and other electronics are enclosed in a box pressurized to approximately one atmosphere, containing dry nitrogen, to provide a level of protection to the electronics from the space environment. The encoded video format supports streaming live video of Earth for viewing online. Camera sensor types include charge-coupled device and complementary metal-oxide semiconductor. Received imagery data is analyzed on the ground to evaluate camera sensor performance. Since payload deployment, minimal degradation to imagery quality has been observed. The HDEV payload continues to operate by live streaming and analyzing imagery. Results from the experiment reduce risk in the selection of cameras that could be considered for future use on the International Space Station and other spacecraft. This paper discusses the payload development, end-to- end architecture, experiment operation, resulting image analysis, and future work.
Johnson, J. R.; Ruff, S.W.; Moersch, J.; Roush, T.; Horton, K.; Bishop, J.; Cabrol, N.A.; Cockell, C.; Gazis, P.; Newsom, Horton E.; Stoker, C.
2001-01-01
Upcoming Mars Surveyor lander missions will include extensive spectroscopic capabilities designed to improve interpretations of the mineralogy and geology of landing sites on Mars. The 1999 Marsokhod Field Experiment (MFE) was a Mars rover simulation designed in part to investigate the utility of visible/near-infrared and thermal infrared field spectrometers to contribute to the remote geological exploration of a Mars analog field site in the California Mojave Desert. The experiment simultaneously investigated the abilities of an off-site science team to effectively analyze and acquire useful imaging and spectroscopic data and to communicate efficiently with rover engineers and an on-site field team to provide meaningful input to rover operations and traverse planning. Experiences gained during the MFE regarding effective communication between different mission operation teams will be useful to upcoming Mars mission teams. Field spectra acquired during the MFE mission exhibited features interpreted at the time as indicative of carbonates (both dolomitic and calcitic), mafic rocks and associated weathering products, and silicic rocks with desert varnish-like coatings. The visible/near-infrared spectra also suggested the presence of organic compounds, including chlorophyll in one rock. Postmission laboratory petrologic and spectral analyses of returned samples confirmed that all rocks identified as carbonates using field measurements alone were calc-silicates and that chlorophyll associated with endolithic organisms was present in the one rock for which it was predicted. Rocks classified from field spectra as silicics and weathered mafics were recognized in the laboratory as metamorphosed monzonites and diorite schists. This discrepancy was likely due to rock coatings sampled by the field spectrometers compared to fresh rock interiors analyzed petrographically, in addition to somewhat different surfaces analyzed by laboratory thermal spectroscopy compared to field spectra. Copyright 2001 by the American Geophysical Union.
[Surgical experience and results in transperitoneal laparoscopic adrenalectomy].
Hevia Suárez, M; Abascal Junquera, J M; Boix, P; Dieguez, M; Delgado, E; Abascal García, J M; Abascal García, R
2010-05-01
Laparoscopic adrenalectomy is currently the gold standard in surgical management of adrenal pathology. To analyze our results after 12 years of experience in this surgery and to compare with the main published series. we describe retrospectively 100 adrenalectomies performed between 1997-2009. Analyzed variables: age, size, side, preoperative diagnosis, operative time, blood loss, reconversion, hospital stay and histopathologic report. We utilized Fisher test and chi square test to compare categoric data. We utilized t-Student test to compare means from independent groups with normal distribution. We considered statistical significance when p<0.05. Mean age was 53.1 years (+/-14.4). Mean size was 3,7 cm (+/-2.2). In 51% of cases it was the left side. Mean follow-up was 15 months (+/-11.9). Preoperative diagnosis was: functional mass (44%), pheocromocytome (17%), incedentaloma>4 cm (20%), metastasis (10%) and adrenal carcinoma (5%). Mean operative time was 145.1 min (+/-55.6). Mean hematocrite loss was 6.26 points (+/-3.3). Reconversion rate was 9.6%. 2 cases of prolonged postoperative ileus. 2 patients required transfusion. 1 patient death because of an descompensation of liver cirrhosis. 80% of complications were on right side. Mean hospital stay was 6 days (+/-5.6). In last 30 procedures we realized statistical differences with first group, in terms of operative time (119.1 min vs 171.2 min) and hospital stay (4.1 days vs 6.1) (p<0.05). Transperitoneal laparoscopic adrenalectomy is a surgical feasible and safe procedure in urological groups with previous laparoscopic experience. Our results are similar with the published series and confirm the efficacy, security and reproducibility of this technique.
The MARTE VNIR imaging spectrometer experiment: design and analysis.
Brown, Adrian J; Sutter, Brad; Dunagan, Stephen
2008-10-01
We report on the design, operation, and data analysis methods employed on the VNIR imaging spectrometer instrument that was part of the Mars Astrobiology Research and Technology Experiment (MARTE). The imaging spectrometer is a hyperspectral scanning pushbroom device sensitive to VNIR wavelengths from 400-1000 nm. During the MARTE project, the spectrometer was deployed to the Río Tinto region of Spain. We analyzed subsets of three cores from Río Tinto using a new band modeling technique. We found most of the MARTE drill cores to contain predominantly goethite, though spatially coherent areas of hematite were identified in Core 23. We also distinguished non Fe-bearing minerals that were subsequently analyzed by X-ray diffraction (XRD) and found to be primarily muscovite. We present drill core maps that include spectra of goethite, hematite, and non Fe-bearing minerals.
The MARTE VNIR Imaging Spectrometer Experiment: Design and Analysis
NASA Astrophysics Data System (ADS)
Brown, Adrian J.; Sutter, Brad; Dunagan, Stephen
2008-10-01
We report on the design, operation, and data analysis methods employed on the VNIR imaging spectrometer instrument that was part of the Mars Astrobiology Research and Technology Experiment (MARTE). The imaging spectrometer is a hyperspectral scanning pushbroom device sensitive to VNIR wavelengths from 400-1000 nm. During the MARTE project, the spectrometer was deployed to the Río Tinto region of Spain. We analyzed subsets of three cores from Río Tinto using a new band modeling technique. We found most of the MARTE drill cores to contain predominantly goethite, though spatially coherent areas of hematite were identified in Core 23. We also distinguished non Fe-bearing minerals that were subsequently analyzed by X-ray diffraction (XRD) and found to be primarily muscovite. We present drill core maps that include spectra of goethite, hematite, and non Fe-bearing minerals.
NASA Astrophysics Data System (ADS)
Drusch, M.
2007-02-01
Satellite-derived surface soil moisture data sets are readily available and have been used successfully in hydrological applications. In many operational numerical weather prediction systems the initial soil moisture conditions are analyzed from the modeled background and 2 m temperature and relative humidity. This approach has proven its efficiency to improve surface latent and sensible heat fluxes and consequently the forecast on large geographical domains. However, since soil moisture is not always related to screen level variables, model errors and uncertainties in the forcing data can accumulate in root zone soil moisture. Remotely sensed surface soil moisture is directly linked to the model's uppermost soil layer and therefore is a stronger constraint for the soil moisture analysis. For this study, three data assimilation experiments with the Integrated Forecast System (IFS) of the European Centre for Medium-Range Weather Forecasts (ECMWF) have been performed for the 2-month period of June and July 2002: a control run based on the operational soil moisture analysis, an open loop run with freely evolving soil moisture, and an experimental run incorporating TMI (TRMM Microwave Imager) derived soil moisture over the southern United States. In this experimental run the satellite-derived soil moisture product is introduced through a nudging scheme using 6-hourly increments. Apart from the soil moisture analysis, the system setup reflects the operational forecast configuration including the atmospheric 4D-Var analysis. Soil moisture analyzed in the nudging experiment is the most accurate estimate when compared against in situ observations from the Oklahoma Mesonet. The corresponding forecast for 2 m temperature and relative humidity is almost as accurate as in the control experiment. Furthermore, it is shown that the soil moisture analysis influences local weather parameters including the planetary boundary layer height and cloud coverage.
Statistical Engineering in Air Traffic Management Research
NASA Technical Reports Server (NTRS)
Wilson, Sara R.
2015-01-01
NASA is working to develop an integrated set of advanced technologies to enable efficient arrival operations in high-density terminal airspace for the Next Generation Air Transportation System. This integrated arrival solution is being validated and verified in laboratories and transitioned to a field prototype for an operational demonstration at a major U.S. airport. Within NASA, this is a collaborative effort between Ames and Langley Research Centers involving a multi-year iterative experimentation process. Designing and analyzing a series of sequential batch computer simulations and human-in-the-loop experiments across multiple facilities and simulation environments involves a number of statistical challenges. Experiments conducted in separate laboratories typically have different limitations and constraints, and can take different approaches with respect to the fundamental principles of statistical design of experiments. This often makes it difficult to compare results from multiple experiments and incorporate findings into the next experiment in the series. A statistical engineering approach is being employed within this project to support risk-informed decision making and maximize the knowledge gained within the available resources. This presentation describes a statistical engineering case study from NASA, highlights statistical challenges, and discusses areas where existing statistical methodology is adapted and extended.
Optical monitoring of scoliosis by 3D medical laser scanner
NASA Astrophysics Data System (ADS)
Rodríguez-Quiñonez, Julio C.; Sergiyenko, Oleg Yu.; Preciado, Luis C. Basaca; Tyrsa, Vera V.; Gurko, Alexander G.; Podrygalo, Mikhail A.; Lopez, Moises Rivas; Balbuena, Daniel Hernandez
2014-03-01
Three dimensional recording of the human body surface or anatomical areas have gained importance in many medical applications. In this paper, our 3D Medical Laser Scanner is presented. It is based on the novel principle of dynamic triangulation. We analyze the method of operation, medical applications, orthopedically diseases as Scoliosis and the most common types of skin to employ the system the most proper way. It is analyzed a group of medical problems related to the application of optical scanning in optimal way. Finally, experiments are conducted to verify the performance of the proposed system and its method uncertainty.
Experimental study of operation performance for hydrocarbon fuel pump with low specific speed
NASA Astrophysics Data System (ADS)
Wu, Xianyu; Yang, Jun; Jin, Xuan
2017-10-01
In this paper, a small flow rate hydrocarbon turbine pump was used to pressurize the fuel supply system of scramjet engine. Some experiments were carried out to investigate the characteristics of turbine pump driven by nitrogen or combustion gas under different operating conditions. A experimental database with regard to the curves of the rotational speed, mass flow rate and net head with regard to centrifugal pump were plotted. These curves were represented as functions of the pressure and temperature at turbine inlet/outlet and the throttle diameter at downstream of centrifugal pump. A sensitivity study has been carried out based on design of experiments. The experimental was employed to analyze net head of centrifugal and throttle characteristics. The research results can accumulate foundations for the close loop control system of turbine pump.
Palamarchuk, V I; Khodos, V A; Vil'gash, A M
2011-10-01
Experience of treatment of 135 patients for varicose disease (VD) of lower extremities (VLE) was analyzed. The investigation objective was the elimination of adverse reactions of general anesthesia and minimization of surgical trauma without loss of the operation radicalism. In 112 (83%) patients a crossectomy (upper and/or lower) was conducted under local infiltrating anesthesia. The criterion for the patients choice for the operation in conditions of local anesthesia was the presence of a VD, independent of its stage. In the investigation were not included the patients, suffering a VD recurrence and its decompensated forms. Our experience witness, that in a certain level of a surgeon qualification present, in a majority of patients, suffering VDLE, including its complicated forms, crossectomy may be performed in conditions of a local anesthesia.
Geometric and Optic Characterization of a Hemispherical Dome Port for Underwater Photogrammetry
Menna, Fabio; Nocerino, Erica; Fassi, Francesco; Remondino, Fabio
2016-01-01
The popularity of automatic photogrammetric techniques has promoted many experiments in underwater scenarios leading to quite impressive visual results, even by non-experts. Despite these achievements, a deep understanding of camera and lens behaviors as well as optical phenomena involved in underwater operations is fundamental to better plan field campaigns and anticipate the achievable results. The paper presents a geometric investigation of a consumer grade underwater camera housing, manufactured by NiMAR and equipped with a 7′′ dome port. After a review of flat and dome ports, the work analyzes, using simulations and real experiments, the main optical phenomena involved when operating a camera underwater. Specific aspects which deal with photogrammetric acquisitions are considered with some tests in laboratory and in a swimming pool. Results and considerations are shown and commented. PMID:26729133
General Purpose Data-Driven Monitoring for Space Operations
NASA Technical Reports Server (NTRS)
Iverson, David L.; Martin, Rodney A.; Schwabacher, Mark A.; Spirkovska, Liljana; Taylor, William McCaa; Castle, Joseph P.; Mackey, Ryan M.
2009-01-01
As modern space propulsion and exploration systems improve in capability and efficiency, their designs are becoming increasingly sophisticated and complex. Determining the health state of these systems, using traditional parameter limit checking, model-based, or rule-based methods, is becoming more difficult as the number of sensors and component interactions grow. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults or failures. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. The scope of IMS based data-driven monitoring applications continues to expand with current development activities. Successful IMS deployment in the International Space Station (ISS) flight control room to monitor ISS attitude control systems has led to applications in other ISS flight control disciplines, such as thermal control. It has also generated interest in data-driven monitoring capability for Constellation, NASA's program to replace the Space Shuttle with new launch vehicles and spacecraft capable of returning astronauts to the moon, and then on to Mars. Several projects are currently underway to evaluate and mature the IMS technology and complementary tools for use in the Constellation program. These include an experiment on board the Air Force TacSat-3 satellite, and ground systems monitoring for NASA's Ares I-X and Ares I launch vehicles. The TacSat-3 Vehicle System Management (TVSM) project is a software experiment to integrate fault and anomaly detection algorithms and diagnosis tools with executive and adaptive planning functions contained in the flight software on-board the Air Force Research Laboratory TacSat-3 satellite. The TVSM software package will be uploaded after launch to monitor spacecraft subsystems such as power and guidance, navigation, and control (GN&C). It will analyze data in real-time to demonstrate detection of faults and unusual conditions, diagnose problems, and react to threats to spacecraft health and mission goals. The experiment will demonstrate the feasibility and effectiveness of integrated system health management (ISHM) technologies with both ground and on-board experiments.
Wu, Lina; Ci, Yusheng; Chu, Jiangwei; Zhang, Hongsheng
2015-01-01
The calculating method for fuel consumption (FC) was put forward and calibrated and the characteristics of the fuel consumption on intersections were analyzed based on 18 groups of vehicular operating data which were acquired from the test experiment of a single vehicle along the urban arterial roads in Harbin, China. The results obtained show that 50.36% of the fuel consumption for the test vehicle was used at the area of intersections compared with 28.9% of the influencing distance and 68.5% of the running time; and 78.4% of them was burnt at the stages of acceleration and idling. Meanwhile, the type (c) of the vehicular operating status was illustrated to be the worst way of reducing fuel consumption, the causes were analyzed and four improvement strategies were put forward. PMID:26367012
Space Experiments with Particle Accelerators (SEPAC)
NASA Technical Reports Server (NTRS)
Obayashi, T.; Kawashima, N.; Kuriki, K.; Nagatomo, M.; Ninomiya, K.; Sasaki, S.; Ushirokawa, A.; Kudo, I.; Ejiri, M.; Roberts, W. T.
1982-01-01
Plans for SEPAC, an instrument array to be used on Spacelab 1 to study vehicle charging and neutralization, beam-plasma interaction in space, beam-atmospheric interaction exciting artificial aurora and airglow, and the electromagnetic-field configuration of the magnetosphere, are presented. The hardware, consisting of electron beam accelerator, magnetoplasma arcjet, neutral-gas plume generator, power supply, diagnostic package (photometer, plasma probes, particle analyzers, and plasma-wave package), TV monitor, and control and data-management unit, is described. The individual SEPAC experiments, the typical operational sequence, and the general outline of the SEPAC follow-on mission are discussed. Some of the experiments are to be joint ventures with AEPI (INS 003) and will be monitored by low-light-level TV.
Thermal and orbital analysis of Earth monitoring Sun-synchronous space experiments
NASA Technical Reports Server (NTRS)
Killough, Brian D.
1990-01-01
The fundamentals of an Earth monitoring Sun-synchronous orbit are presented. A Sun-synchronous Orbit Analysis Program (SOAP) was developed to calculate orbital parameters for an entire year. The output from this program provides the required input data for the TRASYS thermal radiation computer code, which in turn computes the infrared, solar and Earth albedo heat fluxes incident on a space experiment. Direct incident heat fluxes can be used as input to a generalized thermal analyzer program to size radiators and predict instrument operating temperatures. The SOAP computer code and its application to the thermal analysis methodology presented, should prove useful to the thermal engineer during the design phases of Earth monitoring Sun-synchronous space experiments.
Analyzing the security of an existing computer system
NASA Technical Reports Server (NTRS)
Bishop, M.
1986-01-01
Most work concerning secure computer systems has dealt with the design, verification, and implementation of provably secure computer systems, or has explored ways of making existing computer systems more secure. The problem of locating security holes in existing systems has received considerably less attention; methods generally rely on thought experiments as a critical step in the procedure. The difficulty is that such experiments require that a large amount of information be available in a format that makes correlating the details of various programs straightforward. This paper describes a method of providing such a basis for the thought experiment by writing a special manual for parts of the operating system, system programs, and library subroutines.
Sexual Experiences of Chinese Patients Living With an Ostomy.
Zhu, Xiaomei; Chen, Yongyi; Tang, Xinhui; Chen, Yupan; Liu, Yangyu; Guo, Wei; Liu, Aizhong
The purpose of this study was to examine the sexual experience of Chinese patients with ostomy and associated factors. A prospective descriptive study using self-report questionnaires. Seventy-five Chinese participants who underwent ostomy surgery in a large cancer specialist hospital in the Hunan province between 2008 and 2013. Data were collected face-to-face by the investigators in an outpatient setting from 75 participants who completed the Arizona Sexual Experience Inventory Scale (ASEX). The t test was used to compare variances between sexual function and dysfunction subgroups. A multiple linear regression model was used to analyze factors influencing sexual life after ostomy surgery. The mean ASEX score was 20.56 (5.378) years, which is higher than the standard for sexual dysfunction. The main subsection of sexual dysfunction included sexual arousal, orgasm ability, vaginal lubrication/penile erection, and sexual satisfaction. Significant differences in the ASEX score were observed in subgroups of age, gender, educational level, family relations, operation modes, stoma type, operation time, complications, supporters, self-care ability, and sexual life guidance. Multiple stepwise regression analysis indicated that family relations, operation modes, ostomy type, complications, and sexual life guidance affected sexual experience. The findings of this study demonstrate that patients with ostomy experience sexual dysfunction and many factors influence their quality of sexual life. WOC nurses and other healthcare providers should consider providing sexual health education for both the patient and spouse to improve the self-care capacity and quality of sexual life following ostomy surgery.
Twisted Radio Waves and Twisted Thermodynamics
Kish, Laszlo B.; Nevels, Robert D.
2013-01-01
We present and analyze a gedanken experiment and show that the assumption that an antenna operating at a single frequency can transmit more than two independent information channels to the far field violates the Second Law of Thermodynamics. Transmission of a large number of channels, each associated with an angular momenta ‘twisted wave’ mode, to the far field in free space is therefore not possible. PMID:23424647
LapSim virtual reality laparoscopic simulator reflects clinical experience in German surgeons.
Langelotz, C; Kilian, M; Paul, C; Schwenk, W
2005-11-01
The aim of this study was to analyze the ability of a training module on a virtual laparoscopic simulator to assess surgical experience in laparoscopy. One hundred and fifteen participants at the 120th annual convent of the German surgical society took part in this study. All participants were stratified into two groups, one with laparoscopic experience of less than 50 operations (group 1, n=61) and one with laparoscopic experience of more than 50 laparoscopic operations (group 2, n=54). All subjects completed a laparoscopic training module consisting of five different exercises for navigation, coordination, grasping, cutting and clipping. The time to perform each task was measured, as were the path lengths of the instruments and their respective angles representing the economy of the movements. Results between groups were compared using chi(2) or Mann-Whitney U-test. Group 1 needed more time for completion of the exercises (median 424 s, range 99-1,376 s) than group 2 (median 315 s, range 168-625 s) (P<0.01). Instrument movements were less economic in group 1 with larger angular pathways, e.g. in the cutting exercise (median 352 degrees , range 104-1,628 degrees vs median 204 degrees , range 107-444 degrees , P<0.01), and longer path lengths (each instrument P<0.05). As time for completion of exercises, instrument path lengths and angular paths are indicators of clinical experience, it can be concluded that laparoscopic skills acquired in the operating room transfer into virtual reality. A laparoscopic simulator can serve as an instrument for the assessment of experience in laparoscopic surgery.
Drive and protection circuit for converter module of cascaded H-bridge STATCOM
NASA Astrophysics Data System (ADS)
Wang, Xuan; Yuan, Hongliang; Wang, Xiaoxing; Wang, Shuai; Fu, Yongsheng
2018-04-01
Drive and protection circuit is an important part of power electronics, which is related to safe and stable operation issues in the power electronics. The drive and protection circuit is designed for the cascaded H-bridge STATCOM. This circuit can realize flexible dead-time setting, operation status self-detection, fault priority protection and detailed fault status uploading. It can help to improve the reliability of STATCOM's operation. Finally, the proposed circuit is tested and analyzed by power electronic simulation software PSPICE (Simulation Program with IC Emphasis) and a series of experiments. Further studies showed that the proposed circuit can realize drive and control of H-bridge circuit, meanwhile it also can realize fast processing faults and have advantage of high reliability.
A Parylene MEMS Electrothermal Valve
Li, Po-Ying; Givrad, Tina K.; Holschneider, Daniel P.; Maarek, Jean-Michel I.; Meng, Ellis
2011-01-01
The first microelectromechanical-system normally closed electrothermal valve constructed using Parylene C is described, which enables both low power (in milliwatts) and rapid operation (in milliseconds). This low-power valve is well suited for applications in wirelessly controlled implantable drug-delivery systems. The simple design was analyzed using both theory and modeling and then characterized in benchtop experiments. Operation in air (constant current) and water (current ramping) was demonstrated. Valve-opening powers of 22 mW in air and 33 mW in water were obtained. Following integration of the valve with catheters, our valve was applied in a wirelessly operated microbolus infusion pump, and the in vivo functionality for the appropriateness of use of this pump for future brain mapping applications in small animals was demonstrated. PMID:21350679
Baskies, Michael A; Ruchelsman, David E; Capeci, Craig M; Zuckerman, Joseph D; Egol, Kenneth A
2008-04-01
The implementation of Section 405 of the New York State Public Health Code and the adoption of similar policies by the Accreditation Council for Graduate Medical Education in 2002 restricted resident work hours to eighty hours per week. The effect of these policies on operative volume in an orthopaedic surgery residency training program is a topic of concern. The purpose of this study was to evaluate the effect of the work-hour restrictions on the operative experiences of residents in a large university-based orthopaedic surgery residency training program in an urban setting. We analyzed the operative logs of 109 consecutive orthopaedic surgery residents (postgraduate years 2 through 5) from 2000 through 2006, representing a consecutive interval of years before and after the adoption of the work-hour restrictions. Following the implementation of the new work-hour policies, there was no significant difference in the operative volume for postgraduate year-2, 3, or 4 residents. However, the average operative volume for a postgraduate year-5 resident increased from 274.8 to 348.4 cases (p = 0.001). In addition, on analysis of all residents as two cohorts (before 2002 and after 2002), the operative volume for residents increased by an average of 46.6 cases per year (p = 0.02). On the basis of the findings of this study, concerns over the potential adverse effects of the resident work-hour polices on operative volume for orthopaedic surgery residents appear to be unfounded.
NASA Astrophysics Data System (ADS)
Liu, Wei; Li, Ying-jun; Jia, Zhen-yuan; Zhang, Jun; Qian, Min
2011-01-01
In working process of huge heavy-load manipulators, such as the free forging machine, hydraulic die-forging press, forging manipulator, heavy grasping manipulator, large displacement manipulator, measurement of six-dimensional heavy force/torque and real-time force feedback of the operation interface are basis to realize coordinate operation control and force compliance control. It is also an effective way to raise the control accuracy and achieve highly efficient manufacturing. Facing to solve dynamic measurement problem on six-dimensional time-varying heavy load in extremely manufacturing process, the novel principle of parallel load sharing on six-dimensional heavy force/torque is put forward. The measuring principle of six-dimensional force sensor is analyzed, and the spatial model is built and decoupled. The load sharing ratios are analyzed and calculated in vertical and horizontal directions. The mapping relationship between six-dimensional heavy force/torque value to be measured and output force value is built. The finite element model of parallel piezoelectric six-dimensional heavy force/torque sensor is set up, and its static characteristics are analyzed by ANSYS software. The main parameters, which affect load sharing ratio, are analyzed. The experiments for load sharing with different diameters of parallel axis are designed. The results show that the six-dimensional heavy force/torque sensor has good linearity. Non-linearity errors are less than 1%. The parallel axis makes good effect of load sharing. The larger the diameter is, the better the load sharing effect is. The results of experiments are in accordance with the FEM analysis. The sensor has advantages of large measuring range, good linearity, high inherent frequency, and high rigidity. It can be widely used in extreme environments for real-time accurate measurement of six-dimensional time-varying huge loads on manipulators.
System design and animal experiment study of a novel minimally invasive surgical robot.
Wang, Wei; Li, Jianmin; Wang, Shuxin; Su, He; Jiang, Xueming
2016-03-01
Robot-assisted minimally invasive surgery has shown tremendous advances over the traditional technique. However, currently commercialized systems are large and complicated, which vastly raises the system cost and operation room requirements. A MIS robot named 'MicroHand' was developed over the past few years. The basic principle and the key technologies are analyzed in this paper. Comparison between the proposed robot and the da Vinci system is also presented. Finally, animal experiments were carried out to test the performance of MicroHand. Fifteen animal experiments were carried out from July 2013 to December 2013. All animal experiments were finished successfully. The proposed design method is an effective way to resolve the drawbacks of previous generations of the da Vinci surgical system. The animal experiment results confirmed the feasibility of the design. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Cho, G. S.
2017-09-01
For performance optimization of Refrigerated Warehouses, design parameters are selected based on the physical parameters such as number of equipment and aisles, speeds of forklift for ease of modification. This paper provides a comprehensive framework approach for the system design of Refrigerated Warehouses. We propose a modeling approach which aims at the simulation optimization so as to meet required design specifications using the Design of Experiment (DOE) and analyze a simulation model using integrated aspect-oriented modeling approach (i-AOMA). As a result, this suggested method can evaluate the performance of a variety of Refrigerated Warehouses operations.
Δ L =3 processes: Proton decay and the LHC
NASA Astrophysics Data System (ADS)
Fonseca, Renato M.; Hirsch, Martin; Srivastava, Rahul
2018-04-01
We discuss lepton number violation in three units. From an effective field theory point of view, Δ L =3 processes can only arise from dimension 9 or higher operators. These operators also violate baryon number, hence many of them will induce proton decay. Given the high dimensionality of these operators, in order to have a proton half-life in the observable range, the new physics associated to Δ L =3 processes should be at a scale as low as 1 TeV. This opens up the possibility of searching for such processes not only in proton decay experiments but also at the LHC. In this work we analyze the relevant d =9 , 11, 13 operators which violate lepton number in three units. We then construct one simple concrete model with interesting low- and high-energy phenomenology.
MECDAS: A distributed data acquisition system for experiments at MAMI
NASA Astrophysics Data System (ADS)
Krygier, K. W.; Merle, K.
1994-02-01
For the coincidence experiments with the three spectrometer setup at MAMI an experiment control and data acquisition system has been built and was put successfully into final operation in 1992. MECDAS is designed as a distributed system using communication via Ethernet and optical links. As the front end, VME bus systems are used for real time purposes and direct hardware access via CAMAC, Fastbus or VMEbus. RISC workstations running UNIX are used for monitoring, data archiving and online and offline analysis of the experiment. MECDAS consists of several fixed programs and libraries, but large parts of readout and analysis can be configured by the user. Experiment specific configuration files are used to generate efficient and powerful code well adapted to special problems without additional programming. The experiment description is added to the raw collection of partially analyzed data to get self-descriptive data files.
Weakly interacting massive particle-nucleus elastic scattering response
NASA Astrophysics Data System (ADS)
Anand, Nikhil; Fitzpatrick, A. Liam; Haxton, W. C.
2014-06-01
Background: A model-independent formulation of weakly interacting massive particle (WIMP)-nucleon scattering was recently developed in Galilean-invariant effective field theory. Purpose: Here we complete the embedding of this effective interaction in the nucleus, constructing the most general elastic nuclear cross section as a factorized product of WIMP and nuclear response functions. This form explicitly defines what can and cannot be learned about the low-energy constants of the effective theory—and consequently about candidate ultraviolet theories of dark matter—from elastic scattering experiments. Results: We identify those interactions that cannot be reliably treated in a spin-independent/spin-dependent (SI/SD) formulation: For derivative- or velocity-dependent couplings, the SI/SD formulation generally mischaracterizes the relevant nuclear operator and its multipolarity (e.g., scalar or vector) and greatly underestimates experimental sensitivities. This can lead to apparent conflicts between experiments when, in fact, none may exist. The new nuclear responses appearing in the factorized cross section are related to familiar electroweak nuclear operators such as angular momentum l⃗(i) and the spin-orbit coupling σ⃗(i).l⃗(i). Conclusions: To unambiguously interpret experiments and to extract all of the available information on the particle physics of dark matter, experimentalists will need to (1) do a sufficient number of experiments with nuclear targets having the requisite sensitivities to the various operators and (2) analyze the results in a formalism that does not arbitrarily limit the candidate operators. In an appendix we describe a code that is available to help interested readers implement such an analysis.
Simulation of the Francis-99 Hydro Turbine During Steady and Transient Operation
NASA Astrophysics Data System (ADS)
Dewan, Yuvraj; Custer, Chad; Ivashchenko, Artem
2017-01-01
Numerical simulation of the Francis-99 hydroturbine with correlation to experimental measurements are presented. Steady operation of the hydroturbine is analyzed at three operating conditions: the best efficiency point (BEP), high load (HL), and part load (PL). It is shown that global quantities such as net head, discharge and efficiency are well predicted. Additionally, time-averaged velocity predictions compare well with PIV measurements obtained in the draft tube immediately downstream of the runner. Differences in vortex rope structure between operating points are discussed. Unsteady operation of the hydroturbine from BEP to HL and from BEP to PL are modeled. It is shown that simulation methods used to model the steady operation produce predictions that correlate well with experiment for transient operation. Time-domain unsteady simulation is used for both steady and unsteady operation. The full-fidelity geometry including all components is meshed using an unstructured polyhedral mesh with body-fitted prism layers. Guide vane rotation for transient operation is imposed using fully-conservative, computationally efficient mesh morphing. The commercial solver STAR-CCM+ is used for all portions of the analysis including meshing, solving and post-processing.
Takahashi, T; Cárdenas, S; Arch-Ferrer, J; Remes-Troche, J M; Ayala-Ramírez, M; García-Osogobio, S; Mass, W
1999-01-01
Total proctocolectomy with ileal pouch-anal anastomosis (TPCIAA) is the procedure of choice for patients with Ulcerative Colitis and Familial Adenomatous Polyposis. The frequency of presentation of both diseases is low in Mexico, therefore the experience with the surgical procedure is limited. To analyze the operative morbidity and mortality and long-term functional results in a series of patients operated upon with the TPCIAA in a referral center in Mexico. Retrospective analysis of 44 consecutive patients operated upon from 1987 through 1997. The operation included resection of the anal transitional zone, handsewn anastomosis of a "J" pouch, and diverting ileostomy in all cases. Operative morbidity and mortality, and long-term functional results and complications were determined. Mean age was 33 +/- 15 years. There were 52% women and 48% men. Diagnoses were ulcerative colitis in 59% and familial polyposis in 36%. Global morbidity was 39%, and mortality 2%. With a mean follow-up of 24 months, mean number of bowel movements was 4, 10% of patients had diurnal spotting, 30% nocturnal spotting, and no patient had gross incontinence. Three patients presented pouchitis with adequate response to antibiotics. Two patients presented long-term pouch fistulas that did not require pouch excision. The TPCIAA is a feasible operation with acceptable rates of morbidity and mortality and satisfactory functional results.
NASA Astrophysics Data System (ADS)
Feng, Di; Fang, Qimeng; Huang, Huaibo; Zhao, Zhengqi; Song, Ningfang
2017-12-01
The development and implementation of a practical instrument based on an embedded technique for autofocus and polarization alignment of polarization maintaining fiber is presented. For focusing efficiency and stability, an image-based focusing algorithm fully considering the image definition evaluation and the focusing search strategy was used to accomplish autofocus. For improving the alignment accuracy, various image-based algorithms of alignment detection were developed with high calculation speed and strong robustness. The instrument can be operated as a standalone device with real-time processing and convenience operations. The hardware construction, software interface, and image-based algorithms of main modules are described. Additionally, several image simulation experiments were also carried out to analyze the accuracy of the above alignment detection algorithms. Both the simulation results and experiment results indicate that the instrument can achieve the accuracy of polarization alignment <±0.1 deg.
NASA Technical Reports Server (NTRS)
Stapfer, G.; Truscello, V. C.
1975-01-01
For the Multi-Hundred Watt (MHW) Radioisotope Thermoelectric Generator (RTG), the silicon germanium unicouples are coated with silicon nitride to minimize degradation mechanisms which are directly attributable to material sublimation effects. A program is under way to determine the effective vapor suppression of this coating as a function of temperature and gas environment. The results of weight loss experiments, using Si3N4 coated hot shoes (SiMo), operating over a temperature range from 900 C to 1200 C, are analyzed and discussed. These experiments were conducted both in high vacuum and at different pressures of carbon monoxide (CO) to determine its effect on the coating. Although the results show a favorable vapor suppression at all operating temperatures, the pressure of the CO and the thickness of the coating have a decided effect on the useful lifetime of the coating.
Integrated Safety Analysis Teams
NASA Technical Reports Server (NTRS)
Wetherholt, Jonathan C.
2008-01-01
Today's complex systems require understanding beyond one person s capability to comprehend. Each system requires a team to divide the system into understandable subsystems which can then be analyzed with an Integrated Hazard Analysis. The team must have both specific experiences and diversity of experience. Safety experience and system understanding are not always manifested in one individual. Group dynamics make the difference between success and failure as well as the difference between a difficult task and a rewarding experience. There are examples in the news which demonstrate the need to connect the pieces of a system into a complete picture. The Columbia disaster is now a standard example of a low consequence hazard in one part of the system; the External Tank is a catastrophic hazard cause for a companion subsystem, the Space Shuttle Orbiter. The interaction between the hardware, the manufacturing process, the handling, and the operations contributed to the problem. Each of these had analysis performed, but who constituted the team which integrated this analysis together? This paper will explore some of the methods used for dividing up a complex system; and how one integration team has analyzed the parts. How this analysis has been documented in one particular launch space vehicle case will also be discussed.
Backer, H D; Collins, S
1999-04-01
To test the feasibility of using handheld, battery-operated chemical analyzers by EMS personnel in a wilderness environment to aid in the diagnosis and management of heat illness. During the summer of 1996, 3 portable clinical analyzers (i-STAT Corp, Princeton, NJ) were kept at different locations along the main hiking trail into the Grand Canyon. An operational protocol was designed for field use, and Park Service EMS personnel used the instruments at their discretion, primarily to determine serum sodium concentration and identify cases of hyponatremia. Data were collected on all EMS encounters. This study reviews our experience with the instruments. The i-STAT analyzer was used for 64 patients in the backcountry; of these uses, at least 22 were in the field and the remainder in backcountry ranger stations. Eight error messages were recorded in 6 patients. Subsequently, all but 1 had a successful determination. Among patients evacuated for further evaluation and care, serum sodium values were highly consistent with later analysis using standard laboratory equipment. The instrument was used in 31 (48%) of 64 of patients evaluated and released for self-treatment and self-evacuation, and 31 (36%) of 87 of patients evacuated by EMS personnel from the canyon. Nine cases of hyponatremia were confirmed in the field, allowing appropriate intervention. Portable clinical analyzers can reliably be used in a hot wilderness environment. In our application, it allowed identification of exercise-associated hyponatremia, an important cause of serious heat illness during endurance exercise in a hot environment. The results helped make treatment and disposition decisions.
Kniga, V V; Kataman, E A; Kuzmina, A Yu
In January 2015, the Russian aviation medical certification boards adopted the rule of medical certification with OML. The review analyzes the first hands-on experience in medical certification with limitations (OML) of pilots with cardiovascular pathologies in compliance with the guidelines of the International Civil Aviation Organization, European requirements, and overviews the Russian practices of pilots' medical certification.
Hawaii Energy and Environmental Technologies (HEET) Initiative
2011-12-01
polymer electrolyte fuel cells ( PEMFCs ) performance. This work was performed to support the DOE manufacturing initiative for PEMFC production. The work...performed by exposing the MEA cathode to 10 ppm SO2 in N2 at certain potential and typical operating conditions of a PEMFC for certain time, then...adsorbate by analyzing the electrochemical reduction and oxidation potential and charge. As for the in-situ SO2 adsorption experiments, a PEMFC under
Processes in construction of failure management expert systems from device design information
NASA Technical Reports Server (NTRS)
Malin, Jane T.; Lance, Nick
1987-01-01
This paper analyzes the tasks and problem solving methods used by an engineer in constructing a failure management expert system from design information about the device to te diagnosed. An expert test engineer developed a trouble-shooting expert system based on device design information and experience with similar devices, rather than on specific expert knowledge gained from operating the device or troubleshooting its failures. The construction of the expert system was intensively observed and analyzed. This paper characterizes the knowledge, tasks, methods, and design decisions involved in constructing this type of expert system, and makes recommendations concerning tools for aiding and automating construction of such systems.
Meng, Hu; Li, Jiang-Yuan; Tang, Yong-Huai
2009-01-01
The virtual instrument system based on LabVIEW 8.0 for ion analyzer which can measure and analyze ion concentrations in solution is developed and comprises homemade conditioning circuit, data acquiring board, and computer. It can calibrate slope, temperature, and positioning automatically. When applied to determine the reaction rate constant by pX, it achieved live acquiring, real-time displaying, automatical processing of testing data, generating the report of results; and other functions. This method simplifies the experimental operation greatly, avoids complicated procedures of manual processing data and personal error, and improves veracity and repeatability of the experiment results.
A temperature-controlled photoelectrochemical cell for quantitative product analysis.
Corson, Elizabeth R; Creel, Erin B; Kim, Youngsang; Urban, Jeffrey J; Kostecki, Robert; McCloskey, Bryan D
2018-05-01
In this study, we describe the design and operation of a temperature-controlled photoelectrochemical cell for analysis of gaseous and liquid products formed at an illuminated working electrode. This cell is specifically designed to quantitatively analyze photoelectrochemical processes that yield multiple gas and liquid products at low current densities and exhibit limiting reactant concentrations that prevent these processes from being studied in traditional single chamber electrolytic cells. The geometry of the cell presented in this paper enables front-illumination of the photoelectrode and maximizes the electrode surface area to electrolyte volume ratio to increase liquid product concentration and hence enhances ex situ spectroscopic sensitivity toward them. Gas is bubbled through the electrolyte in the working electrode chamber during operation to maintain a saturated reactant concentration and to continuously mix the electrolyte. Gaseous products are detected by an in-line gas chromatograph, and liquid products are analyzed ex situ by nuclear magnetic resonance. Cell performance was validated by examining carbon dioxide reduction on a silver foil electrode, showing comparable results both to those reported in the literature and identical experiments performed in a standard parallel-electrode electrochemical cell. To demonstrate a photoelectrochemical application of the cell, CO 2 reduction experiments were carried out on a plasmonic nanostructured silver photocathode and showed different product distributions under dark and illuminated conditions.
A temperature-controlled photoelectrochemical cell for quantitative product analysis
NASA Astrophysics Data System (ADS)
Corson, Elizabeth R.; Creel, Erin B.; Kim, Youngsang; Urban, Jeffrey J.; Kostecki, Robert; McCloskey, Bryan D.
2018-05-01
In this study, we describe the design and operation of a temperature-controlled photoelectrochemical cell for analysis of gaseous and liquid products formed at an illuminated working electrode. This cell is specifically designed to quantitatively analyze photoelectrochemical processes that yield multiple gas and liquid products at low current densities and exhibit limiting reactant concentrations that prevent these processes from being studied in traditional single chamber electrolytic cells. The geometry of the cell presented in this paper enables front-illumination of the photoelectrode and maximizes the electrode surface area to electrolyte volume ratio to increase liquid product concentration and hence enhances ex situ spectroscopic sensitivity toward them. Gas is bubbled through the electrolyte in the working electrode chamber during operation to maintain a saturated reactant concentration and to continuously mix the electrolyte. Gaseous products are detected by an in-line gas chromatograph, and liquid products are analyzed ex situ by nuclear magnetic resonance. Cell performance was validated by examining carbon dioxide reduction on a silver foil electrode, showing comparable results both to those reported in the literature and identical experiments performed in a standard parallel-electrode electrochemical cell. To demonstrate a photoelectrochemical application of the cell, CO2 reduction experiments were carried out on a plasmonic nanostructured silver photocathode and showed different product distributions under dark and illuminated conditions.
A spectral analysis of the domain decomposed Monte Carlo method for linear systems
Slattery, Stuart R.; Evans, Thomas M.; Wilson, Paul P. H.
2015-09-08
The domain decomposed behavior of the adjoint Neumann-Ulam Monte Carlo method for solving linear systems is analyzed using the spectral properties of the linear oper- ator. Relationships for the average length of the adjoint random walks, a measure of convergence speed and serial performance, are made with respect to the eigenvalues of the linear operator. In addition, relationships for the effective optical thickness of a domain in the decomposition are presented based on the spectral analysis and diffusion theory. Using the effective optical thickness, the Wigner rational approxi- mation and the mean chord approximation are applied to estimate the leakagemore » frac- tion of random walks from a domain in the decomposition as a measure of parallel performance and potential communication costs. The one-speed, two-dimensional neutron diffusion equation is used as a model problem in numerical experiments to test the models for symmetric operators with spectral qualities similar to light water reactor problems. We find, in general, the derived approximations show good agreement with random walk lengths and leakage fractions computed by the numerical experiments.« less
Lv, Houning; Zhao, Ningning; Zheng, Zhongqing; Wang, Tao; Yang, Fang; Jiang, Xihui; Lin, Lin; Sun, Chao; Wang, Bangmao
2017-05-01
Peroral endoscopic myotomy (POEM) has emerged as an advanced technique for the treatment of achalasia, and defining the learning curve is mandatory. From August 2011 to June 2014, two operators in our institution (A&B) carried out POEM on 35 and 33 consecutive patients, respectively. Moving average and cumulative sum (CUSUM) methods were used to analyze the POEM learning curve for corrected operative time (cOT), referring to duration of per centimeter myotomy. Additionally, perioperative outcomes were compared among distinct learning curve phases. Using the moving average method, cOT reached a plateau at the 29th case and at the 24th case for operators A and B, respectively. CUSUM analysis identified three phases: initial learning period (Phase 1), efficiency period (Phase 2) and mastery period (Phase 3). The relatively smooth state in the CUSUM graph occurred at the 26th case and at the 24th case for operators A and B, respectively. Mean cOT of distinct phases for operator A were 8.32, 5.20 and 3.97 min, whereas they were 5.99, 3.06 and 3.75 min for operator B, respectively. Eckardt score and lower esophageal sphincter pressure significantly decreased during the 1-year follow-up period. Data were comparable regarding patient characteristics and perioperative outcomes. This single-center study demonstrated that expert endoscopists with experience in esophageal endoscopic submucosal dissection reached a plateau in learning of POEM after approximately 25 cases. © 2016 Japan Gastroenterological Endoscopy Society.
Hopmans, Cornelis J; den Hoed, Pieter T; van der Laan, Lijckle; van der Harst, Erwin; van der Elst, Maarten; Mannaerts, Guido H H; Dawson, Imro; Timman, Reinier; Wijnhoven, Bas P L; IJzermans, Jan N M
2015-04-01
In Europe and the United States, work hour restrictions are considered to be particularly burdensome for residents in surgery specialties. The aim of this study was to examine whether reduction of the work week to 48 hours resulting from the implementation of the European Working Time Directive has affected the operative experience of surgery residents. This study was conducted in a general surgery training region in the Netherlands, consisting of 1 university hospital and 6 district training hospitals. Operating records summarizing the surgical procedures performed as "primary surgeon" in the operating theater for different grades of surgeons were retrospectively analyzed for the period 2005-2012 by the use of linear regression models. Operative procedures performed by residents were considered the main outcome measure. In total, 235,357 operative procedures were performed, including 47,458 (20.2%) in the university hospital and 187,899 (79.8%) in the district training hospitals (n = 5). For residents in the university hospital, the mean number of operative procedures performed per 1.0 full-time equivalent increased from 128 operations in 2005 to 204 operations in 2012 (P = .001), whereas for residents in district training hospitals, no substantial differences were found over time. The mean (±SD) operative caseload of 64 residents who completed the 6-year training program between 2005 and 2012 was 1,391 ± 226 (range, 768-1856). A comparison of the operative caseload according to year of board-certification showed no difference. Implementation of the European Working Time Directive has not affected adversely the number of surgical procedures performed by residents within a general surgical training region in the Netherlands. Copyright © 2015 Elsevier Inc. All rights reserved.
Technical Competencies Applied in Experimental Fluid Dynamics
NASA Astrophysics Data System (ADS)
Tagg, Randall
2017-11-01
The practical design, construction, and operation of fluid dynamics experiments require a broad range of competencies. Three types are instrumental, procedural, and design. Respective examples would be operation of a spectrum analyzer, soft-soldering or brazing flow plumbing, and design of a small wind tunnel. Some competencies, such as the selection and installation of pumping systems, are unique to fluid dynamics and fluids engineering. Others, such as the design and construction of electronic amplifiers or optical imaging systems, overlap with other fields. Thus the identification and development of learning materials and methods for instruction are part of a larger effort to identify competencies needed in active research and technical innovation.
NASA/ESA CV-990 Spacelab Simulation (ASSESS 2)
NASA Technical Reports Server (NTRS)
1977-01-01
Cost effective techniques for addressing management and operational activities on Spacelab were identified and analyzed during a ten day NASA-ESA cooperative mission with payload and flight responsibilities handled by the organization assigned for early Spacelabs. Topics discussed include: (1) management concepts and interface relationships; (2) experiment selection; (3) hardware development; (4) payload integration and checkout; (5) selection and training of mission specialists and payload specialists; (6) mission control center/payload operations control center interactions with ground and flight problems; (7) real time interaction during flight between principal investigators and the mission specialist/payload specialist flight crew; and (8) retrieval of scientific data and its analysis.
Accuracy comparison among different machine learning techniques for detecting malicious codes
NASA Astrophysics Data System (ADS)
Narang, Komal
2016-03-01
In this paper, a machine learning based model for malware detection is proposed. It can detect newly released malware i.e. zero day attack by analyzing operation codes on Android operating system. The accuracy of Naïve Bayes, Support Vector Machine (SVM) and Neural Network for detecting malicious code has been compared for the proposed model. In the experiment 400 benign files, 100 system files and 500 malicious files have been used to construct the model. The model yields the best accuracy 88.9% when neural network is used as classifier and achieved 95% and 82.8% accuracy for sensitivity and specificity respectively.
Vitale, Salvatore Giovanni; Marilli, Ilaria; Cignini, Pietro; Padula, Francesco; D’Emidio, Laura; Mangiafico, Lucia; Rapisarda, Agnese Maria Chiara; Gulino, Ferdinando Antonio; Cianci, Stefano; Biondi, Antonio; Giorlandino, Claudio
2014-01-01
In the last decades cesarean section rates increased in many countries becoming the most performed intraperitoneal surgical procedure. Despite its worldwide spread, a general consensus on the most appropriate technique to use has not yet been reached. The operative technique performed is made chiefly on the basis of the individual experience and preference of operators, the characteristics of patients, timing and urgency of intervention. We compared the two most known and used techniques, modified Misgav-Ladach and traditional Pfannenstiel-Kerr, and analyzed their impact on primary, short- and long-term outcomes and outcome related to health service use. PMID:26265999
Vitale, Salvatore Giovanni; Marilli, Ilaria; Cignini, Pietro; Padula, Francesco; D'Emidio, Laura; Mangiafico, Lucia; Rapisarda, Agnese Maria Chiara; Gulino, Ferdinando Antonio; Cianci, Stefano; Biondi, Antonio; Giorlandino, Claudio
2014-01-01
In the last decades cesarean section rates increased in many countries becoming the most performed intraperitoneal surgical procedure. Despite its worldwide spread, a general consensus on the most appropriate technique to use has not yet been reached. The operative technique performed is made chiefly on the basis of the individual experience and preference of operators, the characteristics of patients, timing and urgency of intervention. We compared the two most known and used techniques, modified Misgav-Ladach and traditional Pfannenstiel-Kerr, and analyzed their impact on primary, short- and long-term outcomes and outcome related to health service use.
3D Parallel Multigrid Methods for Real-Time Fluid Simulation
NASA Astrophysics Data System (ADS)
Wan, Feifei; Yin, Yong; Zhang, Suiyu
2018-03-01
The multigrid method is widely used in fluid simulation because of its strong convergence. In addition to operating accuracy, operational efficiency is also an important factor to consider in order to enable real-time fluid simulation in computer graphics. For this problem, we compared the performance of the Algebraic Multigrid and the Geometric Multigrid in the V-Cycle and Full-Cycle schemes respectively, and analyze the convergence and speed of different methods. All the calculations are done on the parallel computing of GPU in this paper. Finally, we experiment with the 3D-grid for each scale, and give the exact experimental results.
NASA Technical Reports Server (NTRS)
Weil, Joseph; Sleeman, William C , Jr
1949-01-01
The effects of propeller operation on the static longitudinal stability of single-engine tractor monoplanes are analyzed, and a simple method is presented for computing power-on pitching-moment curves for flap-retracted flight conditions. The methods evolved are based on the results of powered-model wind-tunnel investigations of 28 model configurations. Correlation curves are presented from which the effects of power on the downwash over the tail and the stabilizer effectiveness can be rapidly predicted. The procedures developed enable prediction of power-on longitudinal stability characteristics that are generally in very good agreement with experiment.
Development of uniform and predictable battery materials for nickel-cadmium aerospace cells
NASA Technical Reports Server (NTRS)
1971-01-01
Battery materials and manufacturing methods were analyzed with the aim of developing uniform and predictable battery plates for nickel cadmium aerospace cells. A study is presented for the high temperature electrochemical impregnation process for the preparation of nickel cadmium battery plates. This comparative study is set up as a factorially designed experiment to examine both manufacturing and operational variables and any interaction that might exist between them. The manufacturing variables in the factorial design include plaque preparative method, plaque porosity and thickness, impregnation method, and loading, The operational variables are type of duty cycle, charge and discharge rate, extent of overcharge, and depth of discharge.
The shaped pulses control and operation on the SG-III prototype facility
NASA Astrophysics Data System (ADS)
Ping, Li; Wei, Wang; Sai, Jin; Wanqing, Huang; Wenyi, Wang; Jingqin, Su; Runchang, Zhao
2018-04-01
The laser driven inertial confined fusion experiments require careful temporal shape control of the laser pulse. Two approaches are introduced to improve the accuracy and efficiency of the close loop feedback system for long term operation in TIL; the first one is a statistical model to analyze the variation of the parameters obtained from previous shots, the other is a matrix algorithm proposed to relate the electrical signal and the impulse amplitudes. With the model and algorithm applied in the pulse shaping in TIL, a variety of shaped pulses were produced with a 10% precision in half an hour for almost three years under different circumstance.
NASA Technical Reports Server (NTRS)
1975-01-01
A program was conducted which included the design of a set of simplified simulation tasks, design of apparatus and breadboard TV equipment for task performance, and the implementation of a number of simulation tests. Performance measurements were made under controlled conditions and the results analyzed to permit evaluation of the relative merits (effectivity) of various TV systems. Burden factors were subsequently generated for each TV system to permit tradeoff evaluation of system characteristics against performance. For the general remote operation mission, the 2-view system is recommended. This system is characterized and the corresponding equipment specifications were generated.
Nonlinear Control of Large Disturbances in Magnetic Bearing Systems
NASA Technical Reports Server (NTRS)
Jiang, Yuhong; Zmood, R. B.
1996-01-01
In this paper, the nonlinear operation of magnetic bearing control methods is reviewed. For large disturbances, the effects of displacement constraints and power amplifier current and di/dt limits on bearing control system performance are analyzed. The operation of magnetic bearings exhibiting self-excited large scale oscillations have been studied both experimentally and by simulation. The simulation of the bearing system has been extended to include the effects of eddy currents in the actuators, so as to improve the accuracy of the simulation results. The results of these experiments and simulations are compared, and some useful conclusions are drawn for improving bearing system robustness.
Chiancone, Francesco; Fedelini, Maurizio; Pucci, Luigi; Meccariello, Clemente; Fedelini, Paolo
2017-01-01
ABSTRACT Purpose To describe and analyze our experience with Anderson-Hynes transperitoneal laparoscopic pyeloplasty (LP) in the treatment of recurrent ureteropelvic junction obstruction (UPJO). Materials and methods 38 consecutive patients who underwent transperitoneal laparoscopic redo-pyeloplasty between January 2007 and January 2015 at our department were included in the analysis. 36 patients were previously treated with dismembered pyeloplasty and 2 patients underwent a retrograde endopyelotomy. All patients were symptomatic and all patients had a T1/2>20 minutes at pre-operative DTPA (diethylene-triamine-pentaacetate) renal scan. All data were collected in a prospectively maintained database and retrospectively analyzed. Intraoperative and postoperative complications have been reported according to the Satava and the Clavien-Dindo system. Treatment success was evaluated by a 12 month-postoperative renal scan. Total success was defined as T1/2≤10 minutes while relative success was defined as T1/2between 10 to 20 minutes. Post-operative hydronephrosis and flank pain were also evaluated. Results Mean operating time was 103.16±30 minutes. The mean blood loss was 122.37±73.25mL. The mean postoperative hospital stay was 4.47±0.86 days. No intraoperative complications occurred. 6 out of 38 patients (15.8%) experienced postoperative complications. The success rate was 97.4% for flank pain and 97.4% for hydronephrosis. Post-operative renal scan showed radiological failure in one out of 38 (2.6%) patients, relative success in 2 out of 38 (5.3%) patients and total success in 35 out of 38 (92.1%) of patients. Conclusion Laparoscopic redo-pyeloplasty is a feasible procedure for the treatment of recurrent ureteropelvic junction obstruction (UPJO), with a low rate of post-operative complications and a high success rate in high laparoscopic volume centers. PMID:28191792
The Deep Space Network stability analyzer
NASA Technical Reports Server (NTRS)
Breidenthal, Julian C.; Greenhall, Charles A.; Hamell, Robert L.; Kuhnle, Paul F.
1995-01-01
A stability analyzer for testing NASA Deep Space Network installations during flight radio science experiments is described. The stability analyzer provides realtime measurements of signal properties of general experimental interest: power, phase, and amplitude spectra; Allan deviation; and time series of amplitude, phase shift, and differential phase shift. Input ports are provided for up to four 100 MHz frequency standards and eight baseband analog (greater than 100 kHz bandwidth) signals. Test results indicate the following upper bounds to noise floors when operating on 100 MHz signals: -145 dBc/Hz for phase noise spectrum further than 200 Hz from carrier, 2.5 x 10(exp -15) (tau =1 second) and 1.5 x 10(exp -17) (tau =1000 seconds) for Allan deviation, and 1 x 10(exp -4) degrees for 1-second averages of phase deviation. Four copies of the stability analyzer have been produced, plus one transportable unit for use at non-NASA observatories.
Son, Doo Kyung; Son, Dong Wuk; Kim, Ho Sang; Sung, Soon Ki; Lee, Sang Weon; Song, Geun Sung
2014-08-01
This study analyzed clinical and radiological outcomes of a zero-profile anchored spacer (Zero-P) and conventional cage-plate (CCP) for single level anterior cervical discectomy and fusion (ACDF) to compare the incidence and difference of postoperative dysphagia with both devices. We retrospectively reviewed our experiences of single level ACDF with the CCP and Zero-P. From January 2011 to December 2013, 48 patients who had single level herniated intervertebral disc were operated on using ACDF, with CCP in 27 patients and Zero-P in 21 patients. Patients who received more than double-level ACDF or combined circumferential fusion were excluded. Age, operation time, estimated blood loss (EBL), pre-operative modified Japanese Orthopaedic Association (mJOA) scores, post-operative mJOA scores, achieved mJOA scores and recovery rate of mJOA scores were assessed. Prevertebral soft tissue thickness and postoperative dysphagia were analyzed on the day of surgery, and 2 weeks and 6 months postoperatively. The Zero-P group showed same or favorable clinical and radiological outcomes compared with the CCP group. Postoperative dysphagia was significantly low in the Zero-P group. Application of Zero-P may achieve favorable outcomes and reduce postoperative dysphagia in single level ACDF.
Bol'shakov, O P
2008-01-01
Modern data on studying and teaching topographic and clinical anatomy in Russia and in the foreign countries at the boundary between the XX and the XXI centuries are analyzed. Definitions of some concepts are given; methodological and organizational bases of studying topographic and clinical anatomy are examined in historical aspect. Various approaches to the teaching and studying of these disciplines in different countries, are demonstrated. Special attention is given to the use of new technologies in teaching; the experience of virtual mode of studying of applied anatomy and surgical techniques is critically evaluated. Article presents author's own opinion and analyzes the conceptions of the foreign authors on the necessity of rational combination of computer and other modem technologies with traditional methods of work using biological materials and experiments on laboratory animals. The longstanding experience of the departments of operative surgery and clinical anatomy is summarized and the benefits of the national system of teaching of applied (topographic and clinical) anatomy are shown. Modem tendencies and priorities in the development of topographic and clinical anatomy are demonstrated.
Preparation and operation of space-based experiment on plant growth in KIBO, named Space Seed
NASA Astrophysics Data System (ADS)
Yano, Sachiko; Tanigaki, Fumiaki; Shimazu, Toru; Kasahara, Haruo; Nakamura, Tai; Karahara, Ichirou; Hoson, Takayuki; Kamisaka, Seiichiro
The Japan Aerospace Exploration Agency (JAXA) recently carried out plant growth experiment using the Plant Experiment Unit (PEU) installed in the Cell Biology Experiment Facility (CBEF) onboard KIBO. This experiment named Space Seed was designed to investigate the effect of microgravity on plant growth, especially seed to seed life cycle. Space shuttle STS-128 (17A) carrying eight PEU's was launched to the International Space Station (ISS) on August 28, 2009. The experiment was started on September 10 and terminated on November 11, 2009. The control system of environment in PEU and CBEF worked successfully as planned. In KIBO, Arabidopsis seeds germinated, and bolting and flowering were observed in the PEU's. In the end of March, 2010, Arabidopsis plants harvested in Kibo will be recovered to Earth by the space shuttle mission STS-131(19A) and analyzed for their biological characteristics such as seed fertility, cell wall properties, and gene expression. In this presentation, we describe the outline of the Space Seed experiment. We also describe experimental data such as the control of temperature and humidity in PEUs and CBEF, the onboard operations by the ISS crew, the procedure by which the experiment was monitored from the ground, and brief information about seed germination and subsequent growth under microgravity condition in space. We also succeeded in comparing the results of plant growth in PEUs on onboard 1-G control (Centrifuge) with results in microgravity condition and in ground control.
Study on molecular sieve absorption of ground state HF molecules in a non-chain pulsed HF Laser
NASA Astrophysics Data System (ADS)
Ma, Lianying; Zhou, Songqing; Chao, Huang; Huang, Ke; Zhu, Feng; Luan, Kunpeng; Chen, Hongwei
2017-05-01
This paper describes the principle of non-chain pulsed HF laser, and analyzes the reason why the laser energy dropped severely with the accumulation of shots when the HF laser was in repetitive operation. In order to solve this problem, a molecular sieve absorption device was designed and mounted in the recirculation loop of the HF laser. Measurements of flow velocity indicated that the absorption device would just introduce a small decrease of flow velocity which would not influence the laser operation. Several types of molecular sieve (3A,4A,5A,13X) were used in absorbing experiments and the experiment results inferred that 3A molecular sieve was the most effective sorbent. All the experiments showed that the average drop of the output energy was not more than 5% after 1000 shots at 50Hz/20s. Compared to the energy drop of about 40% without the device, the absorption device could significantly improve the stability of the HF laser output energy and prolong the lifespan of laser medium gases.
Performance Assessment in the PILOT Experiment On Board Space Stations Mir and ISS.
Johannes, Bernd; Salnitski, Vyacheslav; Dudukin, Alexander; Shevchenko, Lev; Bronnikov, Sergey
2016-06-01
The aim of this investigation into the performance and reliability of Russian cosmonauts in hand-controlled docking of a spacecraft on a space station (experiment PILOT) was to enhance overall mission safety and crew training efficiency. The preliminary findings on the Mir space station suggested that a break in docking training of about 90 d significantly degraded performance. Intensified experiment schedules on the International Space Station (ISS) have allowed for a monthly experiment using an on-board simulator. Therefore, instead of just three training tasks as on Mir, five training flights per session have been implemented on the ISS. This experiment was run in parallel but independently of the operational docking training the cosmonauts receive. First, performance was compared between the experiments on the two space stations by nonparametric testing. Performance differed significantly between space stations preflight, in flight, and postflight. Second, performance was analyzed by modeling the linear mixed effects of all variances (LME). The fixed factors space station, mission phases, training task numbers, and their interaction were analyzed. Cosmonauts were designated as a random factor. All fixed factors were found to be significant and the interaction between stations and mission phase was also significant. In summary, performance on the ISS was shown to be significantly improved, thus enhancing mission safety. Additional approaches to docking performance assessment and prognosis are presented and discussed.
Situation awareness and trust in computer-based procedures in nuclear power plant operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Throneburg, E. B.; Jones, J. M.
2006-07-01
Situation awareness and trust are two issues that need to be addressed in the design of computer-based procedures for nuclear power plants. Situation awareness, in relation to computer-based procedures, concerns the operators' knowledge of the plant's state while following the procedures. Trust concerns the amount of faith that the operators put into the automated procedures, which can affect situation awareness. This paper first discusses the advantages and disadvantages of computer-based procedures. It then discusses the known aspects of situation awareness and trust as applied to computer-based procedures in nuclear power plants. An outline of a proposed experiment is then presentedmore » that includes methods of measuring situation awareness and trust so that these aspects can be analyzed for further study. (authors)« less
Impact of various operating modes on performance and emission parameters of small heat source
NASA Astrophysics Data System (ADS)
Vician, Peter; Holubčík, Michal; Palacka, Matej; Jandačka, Jozef
2016-06-01
Thesis deals with the measurement of performance and emission parameters of small heat source for combustion of biomass in each of its operating modes. As the heat source was used pellet boiler with an output of 18 kW. The work includes design of experimental device for measuring the impact of changes in air supply and method for controlling the power and emission parameters of heat sources for combustion of woody biomass. The work describes the main factors that affect the combustion process and analyze the measurements of emissions at the heat source. The results of experiment demonstrate the values of performance and emissions parameters for the different operating modes of the boiler, which serve as a decisive factor in choosing the appropriate mode.
2001-08-01
Apollo-era technology spurred the development of cordless products that we take for granted everyday. In the 1960s, NASA asked Black Decker to develop a special drill that would be powerful enough to cut through hard layers of the lunar surface and be lightweight, compact, and operate under its own power source, allowing Apollo astronauts to collect lunar samples further away from the Lunar Experiment Module. In response, Black Decker developed a computer program that analyzed and optimized drill motor operations. From their analysis, engineers were able to design a motor that was powerful yet required minimal battery power to operate. Since those first days of cordless products, Black Decker has continued to refine this technology and they now sell their rechargeable products worldwide (i.e. the Dustbuster, cordless tools for home and industrial use, and medical tools.)
NASA Technical Reports Server (NTRS)
2001-01-01
Apollo-era technology spurred the development of cordless products that we take for granted everyday. In the 1960s, NASA asked Black Decker to develop a special drill that would be powerful enough to cut through hard layers of the lunar surface and be lightweight, compact, and operate under its own power source, allowing Apollo astronauts to collect lunar samples further away from the Lunar Experiment Module. In response, Black Decker developed a computer program that analyzed and optimized drill motor operations. From their analysis, engineers were able to design a motor that was powerful yet required minimal battery power to operate. Since those first days of cordless products, Black Decker has continued to refine this technology and they now sell their rechargeable products worldwide (i.e. the Dustbuster, cordless tools for home and industrial use, and medical tools.)
Muñoz, Estefanía; Forner, Leopoldo; Llena, Carmen
2014-04-01
The aim of this study was to evaluate the influence of the operator's experience on the shaping of double-curvature simulated root canals with a nickel-titanium single-file reciprocating motion system. Sixty double-curvature root canals simulated in methacrylate blocks were prepared by 10 students without any experience in endodontics and by 10 professionals who had studied endodontics at the postgraduate level. The Reciproc-VDW system's R25 file was used in the root canal preparation. The blocks were photographed before and after the instrumentation, and the time of instrumentation was also evaluated. Changes in root canal dimensions were analyzed in 6 positions. Significant differences (P < .05) were found in the apical transport of the first root canal curvature, with a larger percentage of increase of the root canal occurring in the novice group than in the expert one, as well as in the canal deviation at the beginning of the curvatures, whereas no significant results were obtained in the growth rate of the canal area. There was difference in the time of instrumentation, with 3.76 minutes observed in the novice group, as opposed to 2.05 minutes in the expert group. The use of the single-file reciprocating motion system Reciproc is not seen to be influenced by the operator's experience regarding the increase of the canal area. Previous training and the need to acquire experience are important in the use of this system, in spite of its apparent simplicity. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Caffaro, Federica; Roccato, Michele; Micheletti Cremasco, Margherita; Cavallo, Eugenio
2018-02-01
Objective We investigated the risk factors for falls when egressing from agricultural tractors, analyzing the role played by worked hours, work experience, operators' behavior, and near misses. Background Many accidents occur within the agricultural sector each year. Among them, falls while dismounting the tractor represent a major source of injuries. Previous studies pointed out frequent hazardous movements and incorrect behaviors adopted by operators to exit the tractor cab. However, less is known about the determinants of such behaviors. In addition, near misses are known to be important predictors of accidents, but they have been under-investigated in the agricultural sector in general and as concerns falls in particular. Method A questionnaire assessing dismounting behaviors, previous accidents and near misses, and participants' relation with work was administered to a sample of Italian tractor operators ( n = 286). Results A mediated model showed that worked hours increase unsafe behaviors, whereas work experience decreases them. Unsafe behaviors in turn show a positive association with accidents, via the mediation of near misses. Conclusions We gave a novel contribution to the knowledge of the chain of events leading to fall accidents in the agricultural sector, which is one of the most hazardous industries. Applications Besides tractor design improvements, preventive training interventions may focus on the redesign of the actual working strategies and the adoption of engaging training methods in the use of machinery to optimize the learning of safety practices and safe behaviors.
Love, Tanzy; Carriquiry, Alicia
2009-01-01
We analyze data collected in a somatic embryogenesis experiment carried out on Zea mays at Iowa State University. The main objective of the study was to identify the set of genes in maize that actively participate in embryo development. Embryo tissue was sampled and analyzed at various time periods and under different mediums and light conditions. As is the case in many microarray experiments, the operator scanned each slide multiple times to find the slide-specific ‘optimal’ laser and sensor settings. The multiple readings of each slide are repeated measurements on different scales with differing censoring; they cannot be considered to be replicate measurements in the traditional sense. Yet it has been shown that the choice of reading can have an impact on genetic inference. We propose a hierarchical modeling approach to estimating gene expression that combines all available readings on each spot and accounts for censoring in the observed values. We assess the statistical properties of the proposed expression estimates using a simulation experiment. As expected, combining all available scans using an approach with good statistical properties results in expression estimates with noticeably lower bias and root mean squared error relative to other approaches that have been proposed in the literature. Inferences drawn from the somatic embryogenesis experiment, which motivated this work changed drastically when data were analyzed using the standard approaches or using the methodology we propose. PMID:19960120
Asano, Masanari; Basieva, Irina; Khrennikov, Andrei; Ohya, Masanori; Tanaka, Yoshiharu; Yamato, Ichiro
2012-06-01
We developed a quantum-like model describing the gene regulation of glucose/lactose metabolism in a bacterium, Escherichia coli. Our quantum-like model can be considered as a kind of the operational formalism for microbiology and genetics. Instead of trying to describe processes in a cell in the very detail, we propose a formal operator description. Such a description may be very useful in situation in which the detailed description of processes is impossible or extremely complicated. We analyze statistical data obtained from experiments, and we compute the degree of E. coli's preference within adaptive dynamics. It is known that there are several types of E. coli characterized by the metabolic system. We demonstrate that the same type of E. coli can be described by the well determined operators; we find invariant operator quantities characterizing each type. Such invariant quantities can be calculated from the obtained statistical data.
Chen, Chien-Hsu; Wang, Chuan-Po; Lee, I-Jui; Su, Chris Chun-Chin
2016-01-01
We analyzed the efficacy of the interface design of speech generating devices on three non-verbal adolescents with autism spectrum disorder (ASD), in hopes of improving their on-campus communication and cognitive disability. The intervention program was created based on their social and communication needs in school. Two operating interfaces were designed and compared: the Hierarchical Relating Menu and the Pie Abbreviation-Expansion Menu. The experiment used the ABCACB multiple-treatment reversal design. The test items included: (1) accuracy of operating identification; (2) interface operation in response to questions; (3) degree of independent completion. Each of these three items improved with both intervention interfaces. The children were able to operate the interfaces skillfully and respond to questions accurately, which evidenced the effectiveness of the interfaces. We conclude that both interfaces are efficacious enough to help nonverbal children with ASD at different levels.
Three years of operational experience from Schauinsland CTBT monitoring station.
Zähringer, M; Bieringer, J; Schlosser, C
2008-04-01
Data from three years of operation of a low-level aerosol sampler and analyzer (RASA) at Schauinsland monitoring station are reported. The system is part of the International Monitoring System (IMS) for verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The fully automatic system is capable to measure aerosol borne gamma emitters with high sensitivity and routinely quantifies 7Be and 212Pb. The system had a high level of data availability of 90% within the reporting period. A daily screening process rendered 66 tentative identifications of verification relevant radionuclides since the system entered IMS operation in February 2004. Two of these were real events and associated to a plausible source. The remaining 64 cases can consistently be explained by detector background and statistical phenomena. Inter-comparison with data from a weekly sampler operated at the same station shows instabilities of the calibration during the test phase and a good agreement since certification of the system.
[Hepatic surgery: 10 year experience at the Salvador Zubirán National Institute of Nutrition].
Orozco Zepeda, H; Mercado Díaz, M A; Takahashi Monroy, T; Prado Orozco, E; Chan Núñez, C
1992-01-01
Techniques for surgical liver resections have improved in the last years. The results obtained with liver resections in 67 patients with benign and malignant tumors in a referral hospital for liver diseases in Mexico are analyzed retrospectively, with the aim of knowing the results obtained with such problems in our country. For benign diseases we operated on 36 patients with mean age of 45 years (26 were women), we had one operative death. In 31 patients with operations for malignant tumors (16 were primary liver tumors), the mean age was 52 years and 17 were men; there were eight operative deaths. Major hepatic resections are justified, the results are very satisfactory in benign disease; a major proportion of complications have to be accepted in patients with malignant disease; however, the results are good if we realize that those patients will die in few months if the tumor is not removed.
Xu, Shi-Zhou; Wang, Chun-Jie; Lin, Fang-Li; Li, Shi-Xiang
2017-10-31
The multi-device open-circuit fault is a common fault of ANPC (Active Neutral-Point Clamped) three-level inverter and effect the operation stability of the whole system. To improve the operation stability, this paper summarized the main solutions currently firstly and analyzed all the possible states of multi-device open-circuit fault. Secondly, an order-reduction optimal control strategy was proposed under multi-device open-circuit fault to realize fault-tolerant control based on the topology and control requirement of ANPC three-level inverter and operation stability. This control strategy can solve the faults with different operation states, and can works in order-reduction state under specific open-circuit faults with specific combined devices, which sacrifices the control quality to obtain the stability priority control. Finally, the simulation and experiment proved the effectiveness of the proposed strategy.
Deep-Space Ka-Band Flight Experience
NASA Astrophysics Data System (ADS)
Morabito, D. D.
2017-11-01
Lower frequency bands have become more congested in allocated bandwidth as there is increased competition between flight projects and other entities. Going to higher frequency bands offers significantly more bandwidth, allowing for the use of much higher data rates. However, Ka-band is more susceptible to weather effects than lower frequency bands currently used for most standard downlink telemetry operations. Future or prospective flight projects considering deep-space Ka-band (32-GHz) telemetry data links have expressed an interest in understanding past flight experience with received Ka-band downlink performance. Especially important to these flight projects is gaining a better understanding of weather effects from the experience of current or past missions that operated Ka-band radio systems. We will discuss the historical flight experience of several Ka-band missions starting from Mars Observer in 1993 up to present-day deep-space missions such as Kepler. The study of historical Ka-band flight experience allows one to recommend margin policy for future missions. Of particular interest, we will review previously reported-on flight experience with the Cassini spacecraft Ka-band radio system that has been used for radio science investigations as well as engineering studies from 2004 to 2015, when Cassini was in orbit around the planet Saturn. In this article, we will focus primarily on the Kepler spacecraft Ka-band link, which has been used for operational telemetry downlink from an Earth trailing orbit where the spacecraft resides. We analyzed the received Ka-band signal level data in order to characterize link performance over a wide range of weather conditions and as a function of elevation angle. Based on this analysis of Kepler and Cassini flight data, we found that a 4-dB margin with respect to adverse conditions ensures that we achieve at least a 95 percent data return.
The microgravity environment of the D1 mission
NASA Technical Reports Server (NTRS)
Hamacher, H.; Merbold, U.; Jilg, R.
1990-01-01
Some characteristic features and results of D1 microgravity measurements are discussed as performed in the Material Science Double Rack (MSDR) and the Materials Science Double Rack for Experiment Modules and Apparatus (MEDEA). Starting with a brief review of the main potential disturbances, the payload aspects of interest to the analysis and the accelerometer measuring systems are described. The microgravity data are analyzed with respect to selected mission events such as thruster firings for attitude control, operations of Spacelab experiment facilities, vestibular experiments and crew activities. The origins are divided into orbit, vehicle, and experiment induced perturbations. It has been found that the microgravity-environment is dictated mainly by payload-induced perturbations. To reduce the microgravity-level, the design of some experiment facilities has to be improved by minimizing the number of moving parts, decoupling of disturbing units from experiment facilities, by taking damping measures, etc. In addition, strongly disturbing experiments and very sensitive investigations should be performed in separate mission phases.
NASA Astrophysics Data System (ADS)
Morisson, Marietta; Buch, Arnaud; Szopa, Cyril; Raulin, François; Stambouli, Moncef
2017-04-01
Martian surface is exposed to harsh radiative and oxidative conditions which are destructive for organic molecules. That is why the future ExoMars rover will examine the molecular composition of samples acquired from depths down to two meters below the Martian surface, where organics may have been protected from radiative and oxidative degradation. The samples will then be analyzed by the Pyrolysis-Gas Chromatography-Mass Spectrometry (Pyr-GC-MS) operational mode of the Mars Organic Molecule Analyzer (MOMA) instrument. To prevent thermal alteration of organic molecules during pyrolysis, thermochemolysis with tetramethylammonium hydroxide (TMAH) will extract the organics from the mineral matrix and methylate the polar functional groups, allowing the volatilization of molecules at lower temperatures and protecting the most labile chemical groups from thermal degradation. This study has been carried out on a Martian regolith analogue (JSC-Mars-1) with a high organic content with the aim of optimizing the thermochemolysis temperature within operating conditions similar to the MOMA experiment ones. We also performed Pyrolysis-GC-MS analysis as a comparison. The results show that, unlike pyrolysis alone - which mainly produces aromatics, namely thermally altered molecules - thermochemolysis allows the extraction and identification of numerous organic molecules of astrobiological interest. They also show that the main compounds start to be detectable at low thermochemolysis temperatures ranging from 400°C to 600°C. However, we noticed that the more the temperature increases, the more the chromatograms are saturated with thermally evolved molecules leading to many coelutions and making identification difficult.
NASA Technical Reports Server (NTRS)
1972-01-01
The results of the space station data flow study are reported. Conceived is a low cost interactive data dissemination system for space station experiment data that includes facility and personnel requirements and locations, phasing requirements and implementation costs. Each of the experiments identified by the operating schedule is analyzed and the support characteristics identified in order to determine data characteristics. Qualitative and quantitative comparison of candidate concepts resulted in a proposed data system configuration baseline concept that includes a data center which combines the responsibility of reprocessing, archiving, and user services according to the various agencies and their responsibility assignments. The primary source of data is the space station complex which provides through the Tracking Data Relay Satellite System (TDRS) and by space shuttle delivery data from experiments in free flying modules and orbiting shuttles as well as from the experiments in the modular space station itself.
Ragel, Brian T; Piedra, Mark; Klimo, Paul; Burchiel, Kim J; Waldo, Heidi; McCartney, Shirley; Selden, Nathan R
2014-06-01
In 2003, the Accreditation Council for Graduate Medical Education (ACGME) instituted the 24+6-hour work schedule and 80-hour workweek, and in 2011, it enhanced work hour and supervision standards. In response, Oregon Health & Science University's (OHSU) neurological surgery residency instituted a 3-person night float system. We analyzed work hour records and operative experience for 1 year before and after night float implementation in a model that shortened a combined introductory research and basic clinical neurosciences rotation from 12 to 6 months. We analyzed residents' perception of the system using a confidential survey. The ACGME 2011 work hour standards were applied to both time periods. AFTER NIGHT FLOAT IMPLEMENTATION, THE NUMBER OF DUTY HOUR VIOLATIONS WAS REDUCED: 28-hour shift (11 versus 235), 8 hours off between shifts (2 versus 20), 80 hours per week (0 versus 17), and total violations (23 versus 275). Violations increased only for the less than 4 days off per 4-week interval rule (10 versus 3). No meaningful difference was seen in the number of operative cases performed per year at any postgraduate year (PGY) training level: PGY-2 (336 versus 351), PGY-3 (394 versus 354), PGY-4 (803 versus 802), PGY-5 (1075 versus 1040), PGY-7 (947 versus 913), and total (3555 versus 3460). Residents rated the new system favorably. To meet 2011 ACGME duty hour standards, the OHSU neurological surgery residency instituted a 3-person night float system. A nearly complete elimination of work hour violations did not affect overall resident operative experience.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keren, Y.; Bemporad, G.A.; Rubin, H.
This paper concerns an experimental evaluation of the basic aspects of operation of the advanced solar pond (ASP). Experiments wee carried out in a laboratory test section in order to assess the feasibility of the density gradient maintenance in stratified flowing layers. The density stratification was caused by a non uniform distribution of temperatures in the flow field. Results of the experiments are reported and analyzed in the paper. Experimental data were used in order to calibrate the numerical model able to simulate heat and momentum transfer in the ASP. The numerical results confirmed the validity of the numerical modelmore » adopted, and proved the latter applicability for the simulation of the ASP performance.« less
NASA Technical Reports Server (NTRS)
Sivjee, G. G.
1977-01-01
Results from a comparative study of the feasibility of employing experiment operators on the space shuttle to acquire scientifically worthwhile data are presented. The experiments performed during these tests included spectral observations of the Sun and Venus in the near ultraviolet region. The solar measurements were analyzed to determine ozone abundance in the terrestrial atmosphere. Using a detailed spectral matching technique to compare airborne solar UV measurements with synthetic spectral profiles of sunlight, it is deduced that in winter the total atmospheric ozone abundance is about 0.33 atm/cm at midlatitudes in the northern hemisphere.
Production of Ne Auger electrons by Ne/+/ bombardment of Mg and Al surfaces
NASA Technical Reports Server (NTRS)
Ferrante, J.; Pepper, S. V.
1976-01-01
A description is given of experiments which provide evidence for the production of an inner shell vacancy in the Ne by the asymmetric Ne-Mg and Ne-Al collision. In addition, autoionization states of neutral Ne have been observed. These states are to be distinguished from the more usual case in Auger electron spectroscopy of de-excitation of an ion with a core vacancy. The experiments involved the bombardment of Mg and Al surfaces with Ne(+) ions. A LEED-Auger system equipped with an ion gun and a four-grid retarding potential analyzer operated in the usual dN(E)/dE mode was used.
Spacelab data management subsystem phase B study
NASA Technical Reports Server (NTRS)
1974-01-01
The Spacelab data management system is described. The data management subsystem (DMS) integrates the avionics equipment into an operational system by providing the computations, logic, signal flow, and interfaces needed to effectively command, control, monitor, and check out the experiment and subsystem hardware. Also, the DMS collects/retrieves experiment data and other information by recording and by command of the data relay link to ground. The major elements of the DMS are the computer subsystem, data acquisition and distribution subsystem, controls and display subsystem, onboard checkout subsystem, and software. The results of the DMS portion of the Spacelab Phase B Concept Definition Study are analyzed.
Photonic qubits for remote quantum information processing
NASA Astrophysics Data System (ADS)
Maunz, P.; Olmschenk, S.; Hayes, D.; Matsukevich, D. N.; Duan, L.-M.; Monroe, C.
2009-05-01
Quantum information processing between remote quantum memories relies on a fast and faithful quantum channel. Recent experiments employed both, the photonic polarization and frequency qubits, in order to entangle remote atoms [1, 2], to teleport quantum information [3] and to operate a quantum gate between distant atoms. Here, we compare the dierent schemes used in these experiments and analyze the advantages of the dierent choices of atomic and photonic qubits and their coherence properties. [4pt] [1] D. L. Moehring et al. Nature 449, 68 (2007).[0pt] [2] D. N. Matsukevich et al. Phys. Rev. Lett. 100, 150404 2008).[0pt] [3] S. Olmschenk et al. Science, 323, 486 (2009).
Some in-field experiences of non-synchronous vibrations in large rotating machinery
NASA Technical Reports Server (NTRS)
Colnago, Giuseppe; Frigeri, Claudio; Vallini, Andrea; Zanetta, Gian Antonio
1989-01-01
Some problems associated with non-synchronous vibrations are analyzed by describing three cases experienced with fairly large rotating machines in operating conditions. In each case, a brief description is first given of the machine and of the instrumentation used. The experimental results are then presented, with reference to time or frequency domain recordings. The lines followed in diagnosis are then discussed and, lastly, the corrective action undertaken is presented.
Instrumentation for Mars Environments
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.
1997-01-01
The main portion of the project was to support the "MAE" experiment on the Mars Pathfinder mission and to design instrumentation for future space missions to measure dust deposition on Mars and to characterize the properties of the dust. A second task was to analyze applications for photovoltaics in new space environments, and a final task was analysis of advanced applications for solar power, including planetary probes, photovoltaic system operation on Mars, and satellite solar power systems.
Annotated Bibliography of the Air Force Human Resources Laboratory Technical Reports - 1978
1980-06-01
selection of incentives for classroom use. Grade-related and non -grade-related incentives were described in this experiment in a manner designed to...information monitoring- feedback. The current piractice= materials and methods are an outgroiuth of experimental aJpproache-s to the design . dev...operated in a stand- alone mode, the R & M model can be utilized to analyze the impact of various avionics design configurations on system support
Measurement of rolling friction by a damped oscillator
NASA Technical Reports Server (NTRS)
Dayan, M.; Buckley, D. H.
1983-01-01
An experimental method for measuring rolling friction is proposed. The method is mechanically simple. It is based on an oscillator in a uniform magnetic field and does not involve any mechanical forces except for the measured friction. The measured pickup voltage is Fourier analyzed and yields the friction spectral response. The proposed experiment is not tailored for a particular case. Instead, various modes of operation, suitable to different experimental conditions, are discussed.
2005-01-01
qubits . Suppression of Superconductivity in Granular Metals Igor Beloborodov Argonne National Laboratory, USA We investigate the suppression of...Russia Various strategies for extending coherence times of superconducting qubits have been proposed. We analyze the effect of fluctuations on a... qubit operated at an optimal point in the free- induction decay and the spin-echo-like experiments. Motivated by the recent experimental findings we
[Risk maps. The concept and the methodology for their development].
García Gómez, M M
1994-01-01
In this article the concept of risk map is revised. It is considered as an instrument for the knowledge of risks and damages in a certain environment. A historic revision is made analyzing the birth and evolution of the concept. Different experiences and types of maps in different countries are described. Finally the operative steps, the data sources and the risk indicators which should be used in Spain are included.
Analysis of defects of overhead facade systems and other light thin-walled structures
NASA Astrophysics Data System (ADS)
Endzhievskiy, L.; Frolovskaia, A.; Petrova, Y.
2017-04-01
This paper analyzes the defects and the causes of contemporary design solutions with an example of overhead facade systems with ventilated air gaps and light steel thin-walled structures on the basis of field experiments. The analysis is performed at all stages of work: design, manufacture, including quality, construction, and operation. Practical examples are given. The main causes of accidents and the accident rate prediction are looked upon and discussed.
NASA Astrophysics Data System (ADS)
Cai, Yuanji; Guan, Yonggang; Liu, Weidong
2017-06-01
Transient enclosure voltage (TEV), which is a phenomenon induced by the inner dielectric breakdown of SF6 during disconnector operations in a gas-insulated switchgear (GIS), may cause issues relating to shock hazard and electromagnetic interference to secondary equipment. This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage (UHV) substations. In this paper, the statistical characteristics of TEV at UHV level are collected from field experiments, and are analyzed and compared to those from a repeated strike process. The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first. Then, statistical characteristics, such as the pulse number, duration of pulses, frequency components, magnitude and single pulse duration, are extracted. The transmission line theory is introduced to analyze the TEV and is validated by the experimental results. Finally, the relationship between the TEV and the repeated strike process is analyzed. This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage. The results contribute to the definition of the standard testing waveform of the TEV, and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.
Wagner, Debra L; Lawrence, Stephen; Xu, Jing; Melsom, Janice
2018-04-01
Transporting a newborn out of the operating room after cesarean birth can contribute to maternal awareness of discomfort, anxiety, and the need for administration of analgesics and anxiolytics for relief. This retrospective study analyzed the association between skin-to-skin contact in the operating room and administration of analgesics and anxiolytics to women in the operating and recovery rooms after cesarean birth. Our results indicated a trend toward decreased medication administration for women who experienced skin-to-skin contact and add to evidence supporting the incorporation of skin-to-skin contact in the operating room as the standard of care for cesarean birth. This practice has the potential to enhance the birth experience, promote breastfeeding, and provide greater safety with less exposure to opioids and benzodiazepines for women and their newborns. © 2018 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.
Simulating the Composite Propellant Manufacturing Process
NASA Technical Reports Server (NTRS)
Williamson, Suzanne; Love, Gregory
2000-01-01
There is a strategic interest in understanding how the propellant manufacturing process contributes to military capabilities outside the United States. The paper will discuss how system dynamics (SD) has been applied to rapidly assess the capabilities and vulnerabilities of a specific composite propellant production complex. These facilities produce a commonly used solid propellant with military applications. The authors will explain how an SD model can be configured to match a specific production facility followed by a series of scenarios designed to analyze operational vulnerabilities. By using the simulation model to rapidly analyze operational risks, the analyst gains a better understanding of production complexities. There are several benefits of developing SD models to simulate chemical production. SD is an effective tool for characterizing complex problems, especially the production process where the cascading effect of outages quickly taxes common understanding. By programming expert knowledge into an SD application, these tools are transformed into a knowledge management resource that facilitates rapid learning without requiring years of experience in production operations. It also permits the analyst to rapidly respond to crisis situations and other time-sensitive missions. Most importantly, the quantitative understanding gained from applying the SD model lends itself to strategic analysis and planning.
Software for Analyzing Sequences of Flow-Related Images
NASA Technical Reports Server (NTRS)
Klimek, Robert; Wright, Ted
2004-01-01
Spotlight is a computer program for analysis of sequences of images generated in combustion and fluid physics experiments. Spotlight can perform analysis of a single image in an interactive mode or a sequence of images in an automated fashion. The primary type of analysis is tracking of positions of objects over sequences of frames. Features and objects that are typically tracked include flame fronts, particles, droplets, and fluid interfaces. Spotlight automates the analysis of object parameters, such as centroid position, velocity, acceleration, size, shape, intensity, and color. Images can be processed to enhance them before statistical and measurement operations are performed. An unlimited number of objects can be analyzed simultaneously. Spotlight saves results of analyses in a text file that can be exported to other programs for graphing or further analysis. Spotlight is a graphical-user-interface-based program that at present can be executed on Microsoft Windows and Linux operating systems. A version that runs on Macintosh computers is being considered.
The Phoenix Mars Lander Robotic Arm
NASA Technical Reports Server (NTRS)
Bonitz, Robert; Shiraishi, Lori; Robinson, Matthew; Carsten, Joseph; Volpe, Richard; Trebi-Ollennu, Ashitey; Arvidson, Raymond E.; Chu, P. C.; Wilson, J. J.; Davis, K. R.
2009-01-01
The Phoenix Mars Lander Robotic Arm (RA) has operated for over 150 sols since the Lander touched down on the north polar region of Mars on May 25, 2008. During its mission it has dug numerous trenches in the Martian regolith, acquired samples of Martian dry and icy soil, and delivered them to the Thermal Evolved Gas Analyzer (TEGA) and the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA). The RA inserted the Thermal and Electrical Conductivity Probe (TECP) into the Martian regolith and positioned it at various heights above the surface for relative humidity measurements. The RA was used to point the Robotic Arm Camera to take images of the surface, trenches, samples within the scoop, and other objects of scientific interest within its workspace. Data from the RA sensors during trenching, scraping, and trench cave-in experiments have been used to infer mechanical properties of the Martian soil. This paper describes the design and operations of the RA as a critical component of the Phoenix Mars Lander necessary to achieve the scientific goals of the mission.
[Anesthesia experiences on laparoscopic nephrectomy with da Vinci S robotics].
Mou, Ling; Lan, Zhixun
2015-09-01
To summarize the clinical anesthesia experiences in 20 patients who underwent laparoscopic nephrectomy with da Vinci S robotics. Anesthesia data of 20 patients from Sichuan Provincial People's Hospital, who underwent laparoscopic nephrectomy with da Vinci S robotics from August 2014 to November 2014, were analyzed and summarized. The anesthesia time, operation time, CO(2) pneumoperitoneum time, PaCO(2) and PETCO(2) were recorded. All patients were anesthetized and underwent surgery with da Vinci S robotics. The anesthesia time was (220±14) min, the operation time was (187±11) min, and the CO(2) pneumoperitoneum time was (180±13) min. The PaCO(2) and PETCO(2) were significantly elevated at 1.5 h after operation compared with those at the baseline (before pneumoperitoneum) (P<0.05). The pH value was significantly decreased at 2.5 h after operation compared to that at the baseline (P<0.05). The peak airway pressure of inspiration was significantly elevated at 0.5 h after the beginning of pneumoperitoneum compared to that at the baseline (P<0.05). The hemodynamics is stable during the laparoscopic nephrectomy with da vinci S robotics. However, the duration of CO(2) pneumoperitoneum is significantly increased compared to that of other surgical procedures, resulting in high airway resistance and acid-base disturbance.
Frykman, Philip K; Freedman, Andrew L; Kane, Timothy D; Cheng, Zhi; Petrosyan, Mikael; Catchpole, Kenneth
2017-02-01
We studied operating team acceptability of Video Telescopic Monitor (VITOM ® ) exoscope by exploring the ease of use of the device in two centers. We also assessed factors affecting surgeon musculoskeletal discomfort. We focused on how the operating team interacted with the VITOM system with surrogate measures of usefulness, image quality, ease of use, workload, and setup time. Multivariable linear regression was used to model the relationships between team role, experience, and setup time. Relationships between localized musculoskeletal discomfort and use of VITOM alone, and with loupes, were also analyzed. Four surgeons, 7 surgical techs, 7 circulating nurses, and 13 surgical residents performed 70 pediatric surgical and urological operations. We found that subjective views of each team member were consistently positive with 69%-74% agreed or strongly agreed that VITOM enhanced their ability to perform their job and improved the surgical process. Unexpectedly, the scrub techs and nurses perceived more value and utility of VITOM, presumably because it provides them a view of the operative field that would otherwise be unavailable to them. Team members rated perceptions of image quality highly and workload generally satisfactory. Not surprisingly, setup time decreased with team experience and multivariable modeling showed significant correlations with surgeon and surgical tech experience, but not circulating nurse. An important finding was that surgeon neck discomfort was reduced with use of VITOM alone for magnification, compared with use of loupes and VITOM. The most likely explanation for these findings is improved posture with the neck at a neutral position when viewing the VITOM images, compared with neck flexion with loupes, and thus, a less favorable ergonomic position. This study suggests that there may be small drawbacks associated with VITOM use initially, but these reduce with increased experience and benefit both the surgeon and the rest of the team.
Mobile Computing for Aerospace Applications
NASA Technical Reports Server (NTRS)
Alena, Richard; Swietek, Gregory E. (Technical Monitor)
1994-01-01
The use of commercial computer technology in specific aerospace mission applications can reduce the cost and project cycle time required for the development of special-purpose computer systems. Additionally, the pace of technological innovation in the commercial market has made new computer capabilities available for demonstrations and flight tests. Three areas of research and development being explored by the Portable Computer Technology Project at NASA Ames Research Center are the application of commercial client/server network computing solutions to crew support and payload operations, the analysis of requirements for portable computing devices, and testing of wireless data communication links as extensions to the wired network. This paper will present computer architectural solutions to portable workstation design including the use of standard interfaces, advanced flat-panel displays and network configurations incorporating both wired and wireless transmission media. It will describe the design tradeoffs used in selecting high-performance processors and memories, interfaces for communication and peripheral control, and high resolution displays. The packaging issues for safe and reliable operation aboard spacecraft and aircraft are presented. The current status of wireless data links for portable computers is discussed from a system design perspective. An end-to-end data flow model for payload science operations from the experiment flight rack to the principal investigator is analyzed using capabilities provided by the new generation of computer products. A future flight experiment on-board the Russian MIR space station will be described in detail including system configuration and function, the characteristics of the spacecraft operating environment, the flight qualification measures needed for safety review, and the specifications of the computing devices to be used in the experiment. The software architecture chosen shall be presented. An analysis of the performance characteristics of wireless data links in the spacecraft environment will be discussed. Network performance and operation will be modeled and preliminary test results presented. A crew support application will be demonstrated in conjunction with the network metrics experiment.
NASA Astrophysics Data System (ADS)
Cheng, Fen; Hu, Wanxin
2017-05-01
Based on analysis of the impact of the experience of parking policy at home and abroad, design the impact analysis process of parking strategy. First, using group decision theory to create a parking strategy index system and calculate its weight. Index system includes government, parking operators and travelers. Then, use a multi-level extension theory to analyze the CBD parking strategy. Assess the parking strategy by calculating the correlation of each indicator. Finally, assess the strategy of parking charges through a case. Provide a scientific and reasonable basis for assessing parking strategy. The results showed that the model can effectively analyze multi-target, multi-property parking policy evaluation.
Virtual Instrument for Determining Rate Constant of Second-Order Reaction by pX Based on LabVIEW 8.0
Meng, Hu; Li, Jiang-Yuan; Tang, Yong-Huai
2009-01-01
The virtual instrument system based on LabVIEW 8.0 for ion analyzer which can measure and analyze ion concentrations in solution is developed and comprises homemade conditioning circuit, data acquiring board, and computer. It can calibrate slope, temperature, and positioning automatically. When applied to determine the reaction rate constant by pX, it achieved live acquiring, real-time displaying, automatical processing of testing data, generating the report of results; and other functions. This method simplifies the experimental operation greatly, avoids complicated procedures of manual processing data and personal error, and improves veracity and repeatability of the experiment results. PMID:19730752
The Martian surface as imaged, sampled, and analyzed by the Viking landers
NASA Technical Reports Server (NTRS)
Arvidson, Raymond E.; Gooding, James L.; Moore, Henry J.
1989-01-01
Data collected by two Viking landers are analyzed. Attention is given to the characteristics of the surface inferred from Lander imaging and meteorology data, physical and magnetic properties experiments, and both inorganic and organic analyses of Martian samples. Viking Lander 1 touched down on Chryse Planitia on July 20, 1976 and continued to operate for 2252 sols, until November 20, 1982. Lander 2 touched down about 6500 km away from Lander 1, on Utopia Planitia on September 3, 1976. The chemical compositions of sediments at the two landing sites are similar, suggesting an aeolian origin. The compositions suggest an iron-rich rock an are matched by various clays and salts.
Software for the Integration of Multiomics Experiments in Bioconductor.
Ramos, Marcel; Schiffer, Lucas; Re, Angela; Azhar, Rimsha; Basunia, Azfar; Rodriguez, Carmen; Chan, Tiffany; Chapman, Phil; Davis, Sean R; Gomez-Cabrero, David; Culhane, Aedin C; Haibe-Kains, Benjamin; Hansen, Kasper D; Kodali, Hanish; Louis, Marie S; Mer, Arvind S; Riester, Markus; Morgan, Martin; Carey, Vince; Waldron, Levi
2017-11-01
Multiomics experiments are increasingly commonplace in biomedical research and add layers of complexity to experimental design, data integration, and analysis. R and Bioconductor provide a generic framework for statistical analysis and visualization, as well as specialized data classes for a variety of high-throughput data types, but methods are lacking for integrative analysis of multiomics experiments. The MultiAssayExperiment software package, implemented in R and leveraging Bioconductor software and design principles, provides for the coordinated representation of, storage of, and operation on multiple diverse genomics data. We provide the unrestricted multiple 'omics data for each cancer tissue in The Cancer Genome Atlas as ready-to-analyze MultiAssayExperiment objects and demonstrate in these and other datasets how the software simplifies data representation, statistical analysis, and visualization. The MultiAssayExperiment Bioconductor package reduces major obstacles to efficient, scalable, and reproducible statistical analysis of multiomics data and enhances data science applications of multiple omics datasets. Cancer Res; 77(21); e39-42. ©2017 AACR . ©2017 American Association for Cancer Research.
Spotlight-8 Image Analysis Software
NASA Technical Reports Server (NTRS)
Klimek, Robert; Wright, Ted
2006-01-01
Spotlight is a cross-platform GUI-based software package designed to perform image analysis on sequences of images generated by combustion and fluid physics experiments run in a microgravity environment. Spotlight can perform analysis on a single image in an interactive mode or perform analysis on a sequence of images in an automated fashion. Image processing operations can be employed to enhance the image before various statistics and measurement operations are performed. An arbitrarily large number of objects can be analyzed simultaneously with independent areas of interest. Spotlight saves results in a text file that can be imported into other programs for graphing or further analysis. Spotlight can be run on Microsoft Windows, Linux, and Apple OS X platforms.
Development of Partial Discharging Simulation Test Equipment
NASA Astrophysics Data System (ADS)
Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu
2017-12-01
In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.
Intelligent Modeling for Nuclear Power Plant Accident Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darling, Michael Christropher; Luger, George F.; Jones, Thomas B.
This study explores the viability of using counterfactual reasoning for impact analyses when understanding and responding to “beyond-design-basis” nuclear power plant accidents. Currently, when a severe nuclear power plant accident occurs, plant operators rely on Severe Accident Management Guidelines. However, the current guidelines are limited in scope and depth: for certain types of accidents, plant operators would have to work to mitigate the damage with limited experience and guidance for the particular situation. We aim to fill the need for comprehensive accident support by using a dynamic Bayesian network to aid in the diagnosis of a nuclear reactor’s state andmore » to analyze the impact of possible response measures.« less
Simulation of car movement along circular path
NASA Astrophysics Data System (ADS)
Fedotov, A. I.; Tikhov-Tinnikov, D. A.; Ovchinnikova, N. I.; Lysenko, A. V.
2017-10-01
Under operating conditions, suspension system performance changes which negatively affects vehicle stability and handling. The paper aims to simulate the impact of changes in suspension system performance on vehicle stability and handling. Methods. The paper describes monitoring of suspension system performance, testing of vehicle stability and handling, analyzes methods of suspension system performance monitoring under operating conditions. The mathematical model of a car movement along a circular path was developed. Mathematical tools describing a circular movement of a vehicle along a horizontal road were developed. Turning car movements were simulated. Calculation and experiment results were compared. Simulation proves the applicability of a mathematical model for assessment of the impact of suspension system performance on vehicle stability and handling.
Intelligent Modeling for Nuclear Power Plant Accident Management
Darling, Michael Christropher; Luger, George F.; Jones, Thomas B.; ...
2018-03-29
This study explores the viability of using counterfactual reasoning for impact analyses when understanding and responding to “beyond-design-basis” nuclear power plant accidents. Currently, when a severe nuclear power plant accident occurs, plant operators rely on Severe Accident Management Guidelines. However, the current guidelines are limited in scope and depth: for certain types of accidents, plant operators would have to work to mitigate the damage with limited experience and guidance for the particular situation. We aim to fill the need for comprehensive accident support by using a dynamic Bayesian network to aid in the diagnosis of a nuclear reactor’s state andmore » to analyze the impact of possible response measures.« less
14 CFR 121.434 - Operating experience, operating cycles, and consolidation of knowledge and skills.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Operating experience, operating cycles, and... Qualifications § 121.434 Operating experience, operating cycles, and consolidation of knowledge and skills. (a... position, the operating experience, operating cycles, and the line operating flight time for consolidation...
NASA Technical Reports Server (NTRS)
Lin, Robert P.
1988-01-01
Participation of U.S. scientists on the COPERNIC (COmplete Positive ions, Electrons and Ram Negative Ion measurements near Comet Halley) plasma experiment on the Giotto mission is described. The experiment consisted of two detectors: the EESA (electron electrostatic analyzer) which provided three-dimensional measurements of the distribution of electrons from 10 eV to 30 keV, and the PICCA (positive ion cluster composition analyzer) which provided mass analysis of positively charged cold cometary ions from mass 10 to 210 amu. In addition, a small 3 deg wide sector of the EESA looking in the ram direction was devoted to the detection of negatively charged cold cometary ions. Both detectors operated perfectly up to near closest approach (approx. 600 km) to Halley, but impacts of dust particles and neutral gas on the spacecraft contaminated parts of the data during the last few minutes. Although no flight hardware was fabricated in the U.S., The U.S. made very significant contributions to the hardware design, ground support equipment (GSE) design and fabrication, and flight and data reduction software required for the experiment, and also participated fully in the data reduction and analysis, and theoretical modeling and interpretation. Cometary data analysis is presented.
Operating single quantum emitters with a compact Stirling cryocooler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlehahn, A.; Krüger, L.; Gschrey, M.
2015-01-15
The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, wemore » perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g{sup (2)}(0) < 0.04 from this Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g{sup (2)}(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.« less
NASA Astrophysics Data System (ADS)
Goyal, R.; Gandhi, B. K.; Cervantes, M. J.
2018-06-01
Increased penetration of solar and the wind impels the designers of the hydroelectric power generation unit to provide more flexibility in operation for the stability of the grid. The power generating unit includes turbine which needs to sustain sudden change in its operating conditions. Thus, the hydraulic turbine experiences more transients per day which result in chronic problems such as fatigue to the runner, instrument malfunctioning, vibrations, wear and tear etc. This paper describes experiments performed on a high model (1.5:1) Francis turbine for load acceptances from the minimum load. The experiments presented in the paper are the part of Francis-99 workshop which aims to determine the performance of numerical models in simulations of model Francis turbine under steady and transient operating conditions. The aim of the paper is to present the transient pressure variation in the vaneless space of a Francis turbine where high-frequency pulsations are normally expected. For this, two pressure sensors, VL1 and VL2, are mounted at the vaneless space, one near the beginning of the spiral casing and the other before the end of the spiral casing. Both are used to capture the unsteady pressure field developed in the space between guide vanes and runner inlet. The time-resolved pressure signals are analyzed and presented during the transient to observe the pressure variation and dominant frequencies of pulsations.
Operating single quantum emitters with a compact Stirling cryocooler.
Schlehahn, A; Krüger, L; Gschrey, M; Schulze, J-H; Rodt, S; Strittmatter, A; Heindel, T; Reitzenstein, S
2015-01-01
The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, we perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g((2))(0) < 0.04 from this Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g((2))(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.
Effect of DGPS failures on dynamic positioning of mobile drilling units in the North Sea.
Chen, Haibo; Moan, Torgeir; Verhoeven, Harry
2009-11-01
Basic features of differential global positioning system (DGPS), and its operational configuration on dynamically positioned (DP) mobile offshore drilling units in the North Sea are described. Generic failure modes of DGPS are discussed, and a critical DGPS failure which has the potential to cause drive-off for mobile drilling units is identified. It is the simultaneous erroneous position data from two DGPS's. Barrier method is used to analyze this critical DGPS failure. Barrier elements to prevent this failure are identified. Deficiencies of each barrier element are revealed based on the incidents and operational experiences in the North Sea. Recommendations to strengthen these barrier elements, i.e. to prevent erroneous position data from DGPS, are proposed. These recommendations contribute to the safety of DP operations of mobile offshore drilling units.
NASA Technical Reports Server (NTRS)
Ryan, M. A.; Shevade, A. V.; Manatt, K. S.; Haines, B. E.; Perry, J. L.; Roman, M. C.; Scott, J. P.; Frederick, K. R.
2010-01-01
An electronic nose has been developed at the Jet Propulsion Laboratory (JPL) to monitor spacecraft cabin air for anomalous events such as leaks and spills of solvents, coolants or other fluids with near-real-time analysis. It is designed to operate in the environment of the US Lab on ISS and was deployed on the International Space Station for a seven-month experiment in 2008-2009. In order improve understanding of ENose response to crew activities, an ENose was installed in the Regenerative ECLSS Module Simulator (REMS) at Marshall Space Flight Center (MSFC) for several months. The REMS chamber is operated with continuous analysis of the air for presence and concentration of CO, CO2, ethane, ethanol and methane. ENose responses were analyzed and correlated with logged activities and air analyses in the REMS.
NASA Astrophysics Data System (ADS)
Kirillov, M. V.; Safronov, P. G.
2014-07-01
Efficiency of coal-fired boilers is determined in many respects by optimal operation of the coal-pulverizing plants that are increasingly frequently equipped with pulverizing fans. By an example of retrofitted MV-3300/800/490 pulverizing fans, the effects of different factors on the performance and economic efficiency of the coal-pulverizing plants are analyzed. The experience gained in retrofitting MV-3300/800/490 pulverizing fans by introducing the three-crusher operation mode of a TPE-216 boiler employing the internal recirculation and a blading device in the classifier was also studied. Optimization of the boiler's operation mode was made when switching over from the four-crusher to the three-crusher mode, which considerably improved the engineering and economic characteristics.
Wang, Xianwen; Liu, Zhiguo; Zhang, Wenchang; Wu, Qingfu; Tan, Shulin
2013-08-01
We have designed a mobile operating room information management system. The system is composed of a client and a server. A client, consisting of a PC, medical equipments, PLC and sensors, provides the acquisition and processing of anesthesia and micro-environment data. A server is a powerful computer that stores the data of the system. The client gathers the medical device data by using the C/S mode, and analyzes the obtained HL7 messages through the class library call. The client collects the micro-environment information with PLC, and finishes the data reading with the OPC technology. Experiment results showed that the designed system could manage the patient anesthesia and micro-environment information well, and improve the efficiency of the doctors' works and the digital level of the mobile operating room.
Soft Decision Analyzer and Method
NASA Technical Reports Server (NTRS)
Zucha, Joan P. (Inventor); Schlesinger, Adam M. (Inventor); Lansdowne, Chatwin (Inventor); Steele, Glen F. (Inventor)
2015-01-01
A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.
Soft Decision Analyzer and Method
NASA Technical Reports Server (NTRS)
Zucha, Joan P. (Inventor); Schlesinger, Adam M. (Inventor); Lansdowne, Chatwin (Inventor); Steele, Glen F. (Inventor)
2016-01-01
A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.
Surgical Treatment of Cardiac Echinococcosis: Report of Nine Cases
Papo, Isidor; Ginsberg, Ervin; Albreht, Miša; Martinović, Nebojša; Sokolić, Josip
1982-01-01
We reviewed the results in eight patients followed from 10 months to 22 years after one-stage surgery for removal of primary and secondary myocardial and pericardial hydatid cysts. The results were satisfactory in eight patients who survived the operation. One patient, however, with recurrent myocardial echinococcosis, pulmonary embolization, and sepis died at reoperation. The series was analyzed with reference to the surgical treatment and world-wide experience of complicated cardiac echinococcosis. Images PMID:15226804
Onishenko, G G; Popova, A Iu; Bragina, I V; Kuz'kin, B P; Ezhlova, E B; Demina, Iu V; Gus'kov, A S; Ivanov, G E; Chikina, L V; Klindukhova, V P; Grechanaia, T V; Tesheva, S Ch; Kulichenko, A N; Efremenko, D B; Manin, E A; Kuznetsova, I V; Parkhomenko, V V; Kulichenko, O A; Rafeenko, G K; Shcherbina, L I; Zavora, D L; Briukhanov, A F; Eldinova, V E; Iunicheva, Iu V; Derliatko, S K; Komarov, N S
2015-01-01
The experience of the organization and functioning of the laboratory network during the XXII Olympic Winter Games and XI Paralympic Winter Games of 2014 in Sochi is considered. Efforts to establish an effective system of laboratory support, the order of work and interaction of diagnostic laboratories involved in diseases control of population during the Olympic Games are analyzed.
Assessment of Crew Workload for the RAH-66 Comanche Force Development Experiment 1
2001-10-01
Scale and a cockpit controls and displays usability questionnaire . Results of the assessment indicate that (a) workload was tolerable for the pilots...Workload Levels Between Front Seat and Back Seat 13 3.4 Pilot Responses to Controls and Displays Usability Questionnaire 13 3.5 HMD Symbology 13 4... questionnaire . The data were analyzed to determine if the pilot flying the aircraft (pilot on controls) and the pilot operating the mission equipment
[Design and implementation on smart client for hospital information system].
Liu, Min; Chen, Wei
2009-07-01
The article analyzes the traditional advantages and disadvantages of HIS based on the C/S and B/S structure, and introduces the features of Smart Client technology. Applying the technology in HIS, not only provides excellent operating experience, but also has the benefits of management brought about by concentration of deployment and update, achieve a balanced use of resources. Finally, this paper focuses on the application of the technology in the HIS system architecture design.
[Stigma and resistance among travestis and transsexual women in Salvador, Bahia State, Brazil].
Magno, Laio; Dourado, Inês; Silva, Luis Augusto Vasconcelos da
2018-01-01
This was a qualitative study based on an analysis of narratives produced by travestis and transsexual women in Salvador, Bahia State, Brazil, with the aim of analyzing their experiences with stigmatization by describing events, actors, and contexts that have marked their life stories, as well as elucidating the relationship between stigma and their female performances. The narratives came from 19 in-depth interviews during an epidemiological survey, based on a prior script that explored the production of narratives on lifestyles and experiences of travestis and transsexual women in the city of Salvador. The life stories that emerged in the field were transcribed and analyzed from a theoretical and narrative perspective. The narratives of many travestis and transsexual women described an "effeminate" gender performance that had been identified since their childhood by family and community members. This performance was presented as insubordination to the power established by heteronormative society's legal system. The process of stigmatization begins to operate when social expectations concerning the coherence between "biological sex" and "gender performance" are frustrated in social interactions, submitting the individuals to discrimination and violence. Thus, stigmatization is operated through the power exercised over bodies by the laws of compulsory heterosexuality. However, during the life stories of travestis and transsexual women, strategies of resistance to stigma are produced, with the potential to transform this situation.
Analysis of WBV on standing and seated passengers during off-peak operation in KL monorail
NASA Astrophysics Data System (ADS)
Hasnan, K.; Bakhsh, Q.; Ahmed, A.; Ali, D.; Jamali, A. R.
2018-03-01
In this study, the Whole-Body Vibration (WBV) was analyzed on the standing and seated passenger during off-peak operating hours when train was on the track. The experiments were conducted on two car train at one constant location (bogie-1, which is near to driver’s cabin) during downward direction from KL sentral station towards Titiwangsa station. The aim of this study was to analyze that, in which posture of passenger’s exposures the maximum level of WBV. Since, one passenger was performed the whole journey in standing posture whereas, the other passenger was in seated posture. The result obtained from experiments for the RMS accelerations (Arms), maximum acceleration (Amax) and minimum acceleration (Amin) during the trip. As per standard ISO 2631-1, the daily vibration exposure (A8), Vibration Dose value (VDV) and Crest Factor (CF) of this trip for both standing and sitting orientations were calculated. Results shows that the seated passenger was exposed to longer periods of continuous vibration as compared to the standing passenger. Whereas, the Vibration Dose value (VDV) value was greater than the action value as per ISO 2631-1 and within the limit values. The study concluded that whole body vibration transmitted towards both passengers either standing or seated during their journey. But in overall results comparison of both orientations, the seated passengers gained higher vibration than the standing one.
NASA Astrophysics Data System (ADS)
Jules, Kenol; Lin, Paul P.
2007-06-01
With the International Space Station currently operational, a significant amount of acceleration data is being down-linked, processed and analyzed daily on the ground on a continuous basis for the space station reduced gravity environment characterization, the vehicle design requirements verification and science data collection. To help understand the impact of the unique spacecraft environment on the science data, an artificial intelligence monitoring system was developed, which detects in near real time any change in the reduced gravity environment susceptible to affect the on-going experiments. Using a dynamic graphical display, the monitoring system allows science teams, at any time and any location, to see the active vibration disturbances, such as pumps, fans, compressor, crew exercise, re-boost and extra-vehicular activities that might impact the reduced gravity environment the experiments are exposed to. The monitoring system can detect both known and unknown vibratory disturbance activities. It can also perform trend analysis and prediction by analyzing past data over many increments (an increment usually lasts 6 months) collected onboard the station for selected disturbances. This feature can be used to monitor the health of onboard mechanical systems to detect and prevent potential systems failures. The monitoring system has two operating modes: online and offline. Both near real-time on-line vibratory disturbance detection and off-line detection and trend analysis are discussed in this paper.
Flow Cytometry Technician | Center for Cancer Research
PROGRAM DESCRIPTION The Basic Science Program (BSP) pursues independent, multidisciplinary research in basic and applied molecular biology, immunology, retrovirology, cancer biology, and human genetics. Research efforts and support are an integral part of the Center for Cancer Research (CCR) at the Frederick National Laboratory for Cancer Research (FNLCR). KEY ROLES/RESPONSIBILITIES The Flow Cytometry Core (Flow Core) of the Cancer and Inflammation Program (CIP) is a service core which supports the research efforts of the CCR by providing expertise in the field of flow cytometry (using analyzers and sorters) with the goal of gaining a more thorough understanding of the biology of cancer and cancer cells. The Flow Core provides service to 12-15 CIP laboratories and more than 22 non-CIP laboratories. Flow core staff provide technical advice on the experimental design of applications, which include immunological phenotyping, cell function assays, and cell cycle analysis. Work is performed per customer requirements, and no independent research is involved. The Flow Cytometry Technician will be responsible for: Monitor performance of and maintain high dimensional flow cytometer analyzers and cell sorters Operate high dimensional flow cytometer analyzers and cell sorters Monitoring lab supply levels and order lab supplies, perform various record keeping responsibilities Assist in the training of scientific end users on the use of flow cytometry in their research, as well as how to operate and troubleshoot the bench-top analyzer instruments Experience with sterile technique and tissue culture
The Giotto electron plasma experiment
NASA Technical Reports Server (NTRS)
Reme, H.; Cotin, F.; Cros, A.; Medale, J. L.; Sauvaud, J. A.
1987-01-01
The RPA-Copernic experiment aboard Giotto is described. The experiment is designed to measure the three-dimensional distributions of electrons between 10 eV and 30 keV (by the RPA-1 EESA spectrometer) and the composition and distribution, close to the comet, of thermal positive ions in the mass range 10-213 amu (by the RPA-2 PICCA electrostatic mass analyzer). Three microprocessors interface RPA-1 EESA with RPA-2 PICCA and with the spacecraft and perform extensive onboard data processing. The experiment was operated successfully aboard the spacecraft in September 1985 during the encounter of Giotto with the comet Halley. The results provided by the EESA-1 indicate that the solar wind interaction with the comet Halley forms a well-defined bow shock with features quite different from the features of the comet Giacobini-Zinner bow shock; the data also showed a presence of accelerated keV electrons at the cometary bow shock, upstream and in the transition region.
Development of the electric vehicle analyzer
NASA Astrophysics Data System (ADS)
Dickey, Michael R.; Klucz, Raymond S.; Ennix, Kimberly A.; Matuszak, Leo M.
1990-06-01
The increasing technological maturity of high power (greater than 20 kW) electric propulsion devices has led to renewed interest in their use as a means of efficiently transferring payloads between earth orbits. Several systems and architecture studies have identified the potential cost benefits of high performance Electric Orbital Transfer Vehicles (EOTVs). These studies led to the initiation of the Electric Insertion Transfer Experiment (ELITE) in 1988. Managed by the Astronautics Laboratory, ELITE is a flight experiment designed to sufficiently demonstrate key technologies and options to pave the way for the full-scale development of an operational EOTV. An important consideration in the development of the ELITE program is the capability of available analytical tools to simulate the orbital mechanics of a low thrust, electric propulsion transfer vehicle. These tools are necessary not only for ELITE mission planning exercises but also for continued, efficient, accurate evaluation of DoD space transportation architectures which include EOTVs. This paper presents such a tool: the Electric Vehicle Analyzer (EVA).
Pron, Gaylene; Bennett, John; Common, Andrew; Sniderman, Kenneth; Asch, Murray; Bell, Stuart; Kozak, Roman; Vanderburgh, Leslie; Garvin, Greg; Simons, Martin; Tran, Cuong; Kachura, John
2003-05-01
To document the technical results and spectrum of practice of uterine artery embolization (UAE) for fibroids in the health care setting in Canada. The effects of interventional radiologist's (IR's) experience with UAE on procedure and fluoroscopy time were also investigated. The study involved a multicenter prospective single-arm clinical treatment trial and included the practices of 11 IRs at eight university-affiliated teaching and community hospitals. Vascular access with percutaneous femoral artery approach was followed by transcatheter delivery of polyvinyl alcohol (PVA) particles into uterine arteries with fluoroscopic guidance. Technical success, complications, procedural time, fluoroscopy time, and effects of operator experience were outcomes analyzed. Between November 1998 and November 2000, 570 embolization procedures were performed in 555 patients. UAE was bilaterally successful in 97% (95% CI: 95%-98%). Variant anatomy was the most common reason for failure to embolize bilaterally. The procedural complication rate was 5.3% (95% CI: 3.6%-7.4%). Of the 30 events, three involved major complications (one seizure and two allergic reactions) that resulted in additional care or extended hospital stay. Procedure time and fluoroscopy time averaged 61 minutes (95% CI; 58-63 minutes) and 18.9 minutes (95% CI; 18-19.8) and varied significantly among IRs (P <.001; P <.001). The average 27% reduction in procedure time (20 minutes; P <.001) and 24% reduction in fluoroscopy time (5.1 minutes; P <.001) with increasing UAE experience were significant. A high level of technical success with few complications was obtained with a variety of operators in diverse practice settings. Increased experience in UAE significantly reduced procedure and fluoroscopy time.
Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.
Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen
2017-02-01
ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Quality of life in patients with cleft lip and palate after operation.
Augsornwan, Darawan; Namedang, Sarakull; Pongpagatip, Sumalee; Surakunprapha, Palakorn
2011-12-01
Cleft lip and cleft palate are the most common craniofacial anomalies. Srinagarind Hospital has 150-200 cases each year. The operating process of care, requires continuity of care involving a multidisciplinary team. When the patients go to hospital for an operation they experience pain, limited activity and also food is very different from normal life. When attending school they suffer speech articulation problems and feel shy and isolated, which has a detrimental affect on their life style and quality of life. The main purpose of the study is to the present study quality of life in patients with cleft lip and palate after operation. The present study is descriptive research using qualitative and quantitative approaches. The studied population were patients age 8-18 years old who were admitted at 3C Ward and Outpatient Department, Srinagarind Hospital. 33 patients were interviewed for the quantitative approach. Guideline for in-depth interview with 15 patients were used for the qualitative approach. Quantitative data were analyzed and presented in frequency, percentage and standard deviation. The qualitative data were analyzed through content analysis. Patients consider their QOL is high level, but in detail they still worry about self concept psychological well-being. From indept interview patients would like to get further treatment to minimize their scar as soon as possible. Patients consider their quality of life as high level, but they would like to get further treatment.
Surgical management of gynecomastia: experience of a general surgery center.
Longheu, A; Medas, F; Corrias, F; Farris, S; Tatti, A; Pisano, G; Erdas, E; Calò, P G
2016-01-01
Gynecomastia is a common finding in male population of all ages. The aim of our study was to present our experience and goals in surgical treatment of gynecomastia. Clinical records of patients affected by gynecomastia referred to our Department of Surgery between September 2008 and January 2015 were analyzed. 50 patients were included in this study. Gynecomastia was monolateral in 12 patients (24%) and bilateral in 38 (76%); idiopathic in 41 patients (82%) and secondary in 9 (18%). 39 patients (78%) underwent surgical operation under general anaesthesia, 11 (22%) under local anaesthesia. 3 patients (6%) presented recurrent disease. Webster technique was performed in 28 patients (56%), Davidson technique in 16 patients (32%); in 2 patients (4%) Pitanguy technique was performed and in 4 patients (8%) a mixed surgical technique was performed. Mean surgical time was 80.72±35.14 minutes, median postoperative stay was 1.46±0.88 days. 2 patients (4%) operated using Davidson technique developed a hematoma, 1 patient (2%) operated with the same technique developed hypertrophic scar. Several surgical techniques are described for surgical correction of gynecomastia. If performed by skilled general surgeons surgical treatment of gynecomastia is safe and permits to reach satisfactory aesthetic results.
Park, Jae Hyun; Lee, Jandee; Hakim, Nor Azham; Kim, Ha Yan; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Bae, Keum-Seok; Kang, Seong Joon; Chung, Woong Youn
2015-12-01
This study assessed the results of robotic thyroidectomy by fellowship-trained surgeons in their initial independent practice, and whether standard fellowship training for robotic surgery shortens the learning curve. This prospective cohort study evaluated outcomes in 125 patients who underwent robotic thyroidectomy using gasless transaxillary single-incision technique by 2 recently graduated fellowship-trained surgeons. Learning curves were analyzed by operation time, with proficiency defined as the point at which the slope of the time curve became less steep. Of the 125 patients, 113 underwent robotic less-than-total thyroidectomy, 9 underwent robotic total thyroidectomy and 3 underwent robotic total thyroidectomy with modified radical neck dissection. Mean total times for these 3 operations were 100.8 ± 20.6 minutes, 134.2 ± 38.7 minutes, and 284.7 ± 60.4 minutes, respectively. For both surgeons, the operation times gradually decreased, reaching a plateau after 20 robotic less-than-total thyroidectomies. The surgical learning curve for robotic thyroidectomy performed by recently graduated fellowship-trained surgeons with little or no experience in endoscopic surgery showed excellent results compared with those in a large series of more experienced surgeons. © 2014 Wiley Periodicals, Inc.
Ayala, M; Jiménez, R; García-Osogobio, S; Mass, W; Gómez, F; Remes-Troche, J M; Arch, J; Takahaskhi, T
1999-01-01
Surgical treatment for anorectal fistula may be difficult because of the risk of recurrence, prolonged healing or anal incontinence following the operation. To analyze the experience with the surgical management of ano-rectal fistula during a period of 17 years. The medical records of 105 patients with anorectal fistulas were reviewed retrospectively, with analysis of demographic and clinical data, operative treatment, and results. There were 73% men and 27% women. Mean age was 45 years. 86% had an underlying chronic disease, most frequently diabetes mellitus (21%) and obesity (14%). No anatomic classification of the fistulous tract was done in 86% of cases, and inter-sphincteric tracts were the most frequent type in the classified cases. In 90% of cases, treatment was fistulectomy. Complications occurred in 13% of cases, mainly delayed healing (6.5%). Recurrent disease was documented in 11 cases (10%), and the majority were treated with a new fistulectomy. There were no cases with anal incontinence following the operation. The necessity of performing the anatomic classification of ano-rectal fistula should be emphasized. Fistulectomy was the most frequent surgical procedure.
NASA Technical Reports Server (NTRS)
Molvig, Kim; Batishchev, Oleg
2003-01-01
During this research period the following models of the VASIMR helicon discharge have been further developed and applied to analyze the on-going VX- 10 ASPL experiment: A) 1D semi-analytical model for a mixed-collisional propellant flow B) OD power and balance model for the whole helicon discharge In this particular research period we have concentrated on the MW-level performance of the VASIMR helicon source. Favorable high-power scaling and reduced ionization costs were obtained, and presented at the VASIMR NASA review in the Fall '02. This Grant is continuation of the previous NAG9-1224 award. The research results are summarized in 14 publications; they were presented as 20+ talks at the major International Conferences and scientific seminars at the leading Academic and Research Institutions. The reported results allowed helicon discharge characterization, understanding of the several experimental observations, and helped to make predictions and propose structural modifications for the advanced VASIMR helicon source operation.
Accelerated Aging Experiments for Capacitor Health Monitoring and Prognostics
NASA Technical Reports Server (NTRS)
Kulkarni, Chetan S.; Celaya, Jose Ramon; Biswas, Gautam; Goebel, Kai
2012-01-01
This paper discusses experimental setups for health monitoring and prognostics of electrolytic capacitors under nominal operation and accelerated aging conditions. Electrolytic capacitors have higher failure rates than other components in electronic systems like power drives, power converters etc. Our current work focuses on developing first-principles-based degradation models for electrolytic capacitors under varying electrical and thermal stress conditions. Prognostics and health management for electronic systems aims to predict the onset of faults, study causes for system degradation, and accurately compute remaining useful life. Accelerated life test methods are often used in prognostics research as a way to model multiple causes and assess the effects of the degradation process through time. It also allows for the identification and study of different failure mechanisms and their relationships under different operating conditions. Experiments are designed for aging of the capacitors such that the degradation pattern induced by the aging can be monitored and analyzed. Experimental setups and data collection methods are presented to demonstrate this approach.
Automatic Detection of Driver Fatigue Using Driving Operation Information for Transportation Safety
Li, Zuojin; Chen, Liukui; Peng, Jun; Wu, Ying
2017-01-01
Fatigued driving is a major cause of road accidents. For this reason, the method in this paper is based on the steering wheel angles (SWA) and yaw angles (YA) information under real driving conditions to detect drivers’ fatigue levels. It analyzes the operation features of SWA and YA under different fatigue statuses, then calculates the approximate entropy (ApEn) features of a short sliding window on time series. Using the nonlinear feature construction theory of dynamic time series, with the fatigue features as input, designs a “2-6-6-3” multi-level back propagation (BP) Neural Networks classifier to realize the fatigue detection. An approximately 15-h experiment is carried out on a real road, and the data retrieved are segmented and labeled with three fatigue levels after expert evaluation, namely “awake”, “drowsy” and “very drowsy”. The average accuracy of 88.02% in fatigue identification was achieved in the experiment, endorsing the value of the proposed method for engineering applications. PMID:28587072
Automatic Detection of Driver Fatigue Using Driving Operation Information for Transportation Safety.
Li, Zuojin; Chen, Liukui; Peng, Jun; Wu, Ying
2017-05-25
Fatigued driving is a major cause of road accidents. For this reason, the method in this paper is based on the steering wheel angles (SWA) and yaw angles (YA) information under real driving conditions to detect drivers' fatigue levels. It analyzes the operation features of SWA and YA under different fatigue statuses, then calculates the approximate entropy (ApEn) features of a short sliding window on time series. Using the nonlinear feature construction theory of dynamic time series, with the fatigue features as input, designs a "2-6-6-3" multi-level back propagation (BP) Neural Networks classifier to realize the fatigue detection. An approximately 15-h experiment is carried out on a real road, and the data retrieved are segmented and labeled with three fatigue levels after expert evaluation, namely "awake", "drowsy" and "very drowsy". The average accuracy of 88.02% in fatigue identification was achieved in the experiment, endorsing the value of the proposed method for engineering applications.
Flow Cytometry Scientist | Center for Cancer Research
PROGRAM DESCRIPTION The Basic Science Program (BSP) pursues independent, multidisciplinary research in basic and applied molecular biology, immunology, retrovirology, cancer biology, and human genetics. Research efforts and support are an integral part of the Center for Cancer Research (CCR) at the Frederick National Laboratory for Cancer Research (FNLCR). KEY ROLES/RESPONSIBILITIES The Flow Cytometry Core (Flow Core) in the Cancer and Inflammation Program (CIP) is a service core which supports the research efforts of the CCR by providing expertise in the field of flow cytometry (using analyzers and sorters) with the goal of gaining a more thorough understanding of the biology of the immune system, cancer, and inflammation processes. The Flow Core provides service to 12-15 CIP laboratories and more than 22 non-CIP laboratories. Flow core staff provide technical advice on the experimental design of applications, which include immunological phenotyping, cell function assays, and cell cycle analysis. Work is performed per customer requirements, and no independent research is involved. The Flow Cytometry Scientist will be responsible for: Daily management of the Flow Cytometry Core, to include the supervision and guidance of technical staff members Monitor performance of and maintain high dimensional flow cytometer analyzers and cell sorters Operate high dimensional flow cytometer analyzers and cell sorters Provide scientific expertise to the user community and facilitate the development of cutting edge technologies Interact with Flow Core users and customers, and provide technical and scientific advice, and guidance regarding their experiments, including possible collaborations Train staff and scientific end users on the use of flow cytometry in their research, as well as teach them how to operate and troubleshoot the bench-top analyzer instruments Prepare and deliver lectures, as well as one-on-one training sessions, with customers/users Ensure that protocols are up-to-date, and appropriately adhered to Experience with sterile technique and tissue culture
The role of first impression in operant learning.
Shteingart, Hanan; Neiman, Tal; Loewenstein, Yonatan
2013-05-01
We quantified the effect of first experience on behavior in operant learning and studied its underlying computational principles. To that goal, we analyzed more than 200,000 choices in a repeated-choice experiment. We found that the outcome of the first experience has a substantial and lasting effect on participants' subsequent behavior, which we term outcome primacy. We found that this outcome primacy can account for much of the underweighting of rare events, where participants apparently underestimate small probabilities. We modeled behavior in this task using a standard, model-free reinforcement learning algorithm. In this model, the values of the different actions are learned over time and are used to determine the next action according to a predefined action-selection rule. We used a novel nonparametric method to characterize this action-selection rule and showed that the substantial effect of first experience on behavior is consistent with the reinforcement learning model if we assume that the outcome of first experience resets the values of the experienced actions, but not if we assume arbitrary initial conditions. Moreover, the predictive power of our resetting model outperforms previously published models regarding the aggregate choice behavior. These findings suggest that first experience has a disproportionately large effect on subsequent actions, similar to primacy effects in other fields of cognitive psychology. The mechanism of resetting of the initial conditions that underlies outcome primacy may thus also account for other forms of primacy. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Primary benign brachial plexus tumors: an experience of 115 operated cases.
Desai, Ketan I
2012-01-01
Primary benign brachial plexus tumors are rare. They pose a great challenge to the neurosurgeon, because the majority of patients present with minimal or no neurological deficits. Radical to complete excision of the tumor with preservation of neurological function of the involved nerve is an ideal surgical treatment option with benign primary brachial plexus tumor surgery. We present a review article of our 10-year experience with primary benign brachial plexus tumors surgically treated at King Edward Memorial Hospital and P.D. Hinduja National Hospital from 2000 to 2009. The clinical presentations, radiological features, surgical strategies, and the eventual outcome following surgery are analyzed, discussed, and compared with available series in the world literature. Various difficulties and problems faced in the management of primary benign brachial plexus tumors are analyzed. Irrespective of the tumor size, the indications for surgical intervention are also discussed. The goal of our study was to optimize the treatment of patients with benign brachial plexus tumors with minimal neurological deficits. It is of paramount importance that brachial plexus tumors be managed by a peripheral nerve surgeon with expertise and experience in this field to minimize the neurological insult following surgery.
Mountain Heavy Rainfall Measurement Experiments in a Subtropical Monsoon Environment
NASA Astrophysics Data System (ADS)
Jong-Dao Jou, Ben; Chi-June Jung, Ultimate; Lai, Hsiao-Wei; Feng, Lei
2014-05-01
Quantitative rainfall measurement experiments have been conducted in Taiwan area for the past 5 years (since 2008), especially over the complex terrain region. In this paper, results from these experiments will be analyzed and discussed, especially those associated with heavy rain events in the summer monsoon season. Observations from s-band polarimetric radar (SPOL of NCAR) and also x-band vertically-pointing radar are analyzed to reveal the high resolution temporal and spatial variation of precipitation structure. May and June, the Meiyu season in the area, are months with subtropical frontal rainfall events. Mesoscale convective systems, i.e., pre-frontal squall lines and frontal convective rainbands, are very active and frequently produce heavy rain events over mountain areas. Accurate quantitative precipitation measurements are needed in order to meet the requirement for landslide and flood early warning purpose. Using ground-based disdrometers and vertically-pointing radar, we have been trying to modify the quantitative precipitation estimation in the mountain region by using coastal operational radar. In this paper, the methodology applied will be presented and the potential of its application will be discussed. *corresponding author: Ben Jong-Dao Jou, jouben43@gmail.com
Financial protection against nuclear hazards: thirty years' experience under the Price-Anderson Act
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rockett, L.R.; Hayn, I.
1984-01-01
The purpose of this study is to evaluate the operation of the Price-Anderson Act in the light of the last 10 years' experience and the changes that have occurred during that period both in the law and regulations and in the nuclear and insurance industries, and to provide an independent analysis of various proposals to extend or amend the Act prior to its 1987 expiration. The report does not analyze the impact of the Silkwood v. Kerr McGee Corp. decision. The five chapters cover historical background, financial protection under the Price-Anderson Act and in the absence of the Act, fundamentalmore » policy issues, and alternative proposals.« less
Pretest mediction of Semiscale Test S-07-10 B. [PWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobbe, C A
A best estimate prediction of Semiscale Test S-07-10B was performed at INEL by EG and G Idaho as part of the RELAP4/MOD6 code assessment effort and as the Nuclear Regulatory Commission pretest calculation for the Small Break Experiment. The RELAP4/MOD6 Update 4 and the RELAP4/MOD7 computer codes were used to analyze Semiscale Test S-07-10B, a 10% communicative cold leg break experiment. The Semiscale Mod-3 system utilized an electrially heated simulated core operating at a power level of 1.94 MW. The initial system pressure and temperature in the upper plenum was 2276 psia and 604/sup 0/F, respectively.
Toward autonomous rotorcraft flight in degraded visual environments: experiments and lessons learned
NASA Astrophysics Data System (ADS)
Stambler, Adam; Spiker, Spencer; Bergerman, Marcel; Singh, Sanjiv
2016-05-01
Unmanned cargo delivery to combat outposts will inevitably involve operations in degraded visual environments (DVE). When DVE occurs, the aircraft autonomy system needs to be able to function regardless of the obscurant level. In 2014, Near Earth Autonomy established a baseline perception system for autonomous rotorcraft operating in clear air conditions, when its m3 sensor suite and perception software enabled autonomous, no-hover landings onto unprepared sites populated with obstacles. The m3's long-range lidar scanned the helicopter's path and the perception software detected obstacles and found safe locations for the helicopter to land. This paper presents the results of initial tests with the Near Earth perception system in a variety of DVE conditions and analyzes them from the perspective of mission performance and risk. Tests were conducted with the m3's lidar and a lightweight synthetic aperture radar in rain, smoke, snow, and controlled brownout experiments. These experiments showed the capability to penetrate through mild DVE but the perceptual capabilities became degraded with the densest brownouts. The results highlight the need for not only improved ability to see through DVE, but also for improved algorithms to monitor and report DVE conditions.
Basis for the power supply reliability study of the 1 MW neutron source
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGhee, D.G.; Fathizadeh, M.
1993-07-01
The Intense Pulsed Neutron Source (IPNS) upgrade to 1 MW requires new power supply designs. This paper describes the tools and the methodology needed to assess the reliability of the power supplies. Both the design and operation of the power supplies in the synchrotron will be taken into account. To develop a reliability budget, the experiments to be conducted with this accelerator are reviewed, and data is collected on the number and duration of interruptions possible before an experiment is required to start over. Once the budget is established, several accelerators of this type will be examined. The budget ismore » allocated to the different accelerator systems based on their operating experience. The accelerator data is usually in terms of machine availability and system down time. It takes into account mean time to failure (MTTF), time to diagnose, time to repair or replace the failed components, and time to get the machine back online. These estimated times are used as baselines for the design. Even though we are in the early stage of design, available data can be analyzed to estimate the MTTF for the power supplies.« less
A large ion beam device for laboratory solar wind studies
NASA Astrophysics Data System (ADS)
Ulibarri, Zach; Han, Jia; Horányi, Mihály; Munsat, Tobin; Wang, Xu; Whittall-Scherfee, Guy; Yeo, Li Hsia
2017-11-01
The Colorado Solar Wind Experiment is a new device constructed at the Institute for Modeling Plasma, Atmospheres, and Cosmic Dust at the University of Colorado. A large cross-sectional Kaufman ion source is used to create steady state plasma flow to model the solar wind in an experimental vacuum chamber. The plasma beam has a diameter of 12 cm at the source, ion energies of up to 1 keV, and ion flows of up to 0.1 mA/cm2. Chamber pressure can be reduced to 4 × 10-5 Torr under operating conditions to suppress ion-neutral collisions and create a monoenergetic ion beam. The beam profile has been characterized by a Langmuir probe and an ion energy analyzer mounted on a two-dimensional translation stage. The beam profile meets the requirements for planned experiments that will study solar wind interaction with lunar magnetic anomalies, the charging and dynamics of dust in the solar wind, plasma wakes and refilling, and the wakes of topographic features such as craters or boulders. This article describes the technical details of the device, initial operation and beam characterization, and the planned experiments.
Report of the Dutch experience with the Ross procedure in 343 patients.
Takkenberg, J J M; Dossche, K M E; Hazekamp, M G; Nijveld, A; Jansen, E W L; Waterbolk, T W; Bogers, A J J C
2002-07-01
Limited information is available on outcome after autograft aortic valve replacement, in particular with respect to the durability of the autograft and of the allograft used to reconstruct the right ventricular outflow tract. A retrospective follow-up study of all patients who underwent a Ross procedure in the Netherlands since 1988 was done to obtain an overview of the Dutch experience with this procedure. From 1988 to January 2000, 348 Ross procedures were performed in nine centers in the Netherlands. Pre-operative, peri-operative and follow-up data from 343 patients in seven centers (99% of all Dutch autograft patients) were collected and analyzed. Mean patient age was 26 years (SD 14, range 0-58) and male/female ratio was 2.1. Bicuspid valve or other congenital heart valve disease was the most common indication for operation. The root replacement technique was used in 95% of patients and concomitant procedures were done in 12%. Hospital mortality was 2.6% (N=9). Mean follow-up was 4 years (median 3.8, SD 2.8, range 0-12.5). Overall cumulative survival was 96% at 1 year (95% confidence interval (CI) 94-98%) and 94% at 5 and 7 post-operative years, respectively (95% CI 91-97%). At last follow-up, 87% of the surviving patients was in New York Heart Association (NYHA) class I. Independent predictors of overall mortality were pre-operative NYHA class IV/V and longer perfusion time. Autograft reoperation had to be performed in 14 patients and reintervention on the pulmonary allograft in 10 patients. Freedom from any valve-related reintervention was 88% at 7 years (95% CI 81-94%). The Dutch experience with the Ross procedure is favorable, with low operative mortality and good mid-term results. Although both the autograft in aortic position and the allograft in the right ventricular outflow tract have a limited durability, this has not yet resulted in considerable reoperation rates and associated morbidity and mortality.
Ravindra, Pravisha; Fitzgerald, J Edward F; Bhangu, Aneel; Maxwell-Armstrong, Charles A
2013-01-01
Operating room experience offers a unique learning resource, potentially exposing medical students to surgical disease and treatments, use of anesthesia, basic science, team working, and communication skills. However, the alien nature of this environment to newcomers poses particular difficulties in harnessing this resource. This study aimed to assess the operating theater-based teaching and learning experiences of new medical graduates during their medical school course. A 41-item, self-administered questionnaire survey was distributed to newly qualified medical school graduates from 1 university consisting of 5 separate teaching hospitals. Results were analyzed using GraphPad Prism 5.0. Questionnaires were returned by 209 of 312 graduates (67%). Overall, 121 (59%) respondents attended ≤50% of opportunities available to attend operating theater; 47% felt they knew what was expected of them when attending and only 13% had specific learning objectives set. An interest in pursuing a surgical career was stated by 24 (12%) respondents; this group was more likely to have attended ≥50% of operating theater opportunities (p = 0.0064). Those not intending to pursue a surgical career were more likely to have been discouraged by their experiences (p = 0.0001). Active participation while scrubbed, knowing what was expected, being made to feel welcome, and being set learning objectives were all significantly positively correlated with attendance. Although female respondents felt equally welcome, in comparison with their male colleagues, they were more likely to receive negative comments (p = 0.0106). The majority of respondents (80%) stated that attendance at operating theater sessions should be a mandatory component of the curriculum. Although operating theater attendance is recognized as an important component of the medical school curriculum, overall attendance at sessions was low. Attendance could be increased by ensuring students knowing what is expected of them, making them feel welcome, setting learning objectives, and allowed them to actively participate. These results highlight the need to ensure that the time spent by medical students in the operating room is positive and maximized to its full potential through structured learning involving all members of the theater team. Copyright © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
War stories: a qualitative analysis of narrative teaching strategies in the operating room.
Hu, Yue-Yung; Peyre, Sarah E; Arriaga, Alexander F; Roth, Emilie M; Corso, Katherine A; Greenberg, Caprice C
2012-01-01
"War stories" are commonplace in surgical education, yet little is known about their purpose, construct, or use in the education of trainees. Ten complex operations were videotaped and audiotaped. Narrative stories were analyzed using grounded theory to identify emergent themes in both the types of stories being told and the teaching objectives they illustrated. Twenty-four stories were identified in 9 of the 10 cases (mean, 2.4/case). They were brief (mean, 58 seconds), illustrative of multiple teaching points (mean, 1.5/story), and appeared throughout the operations. Anchored in personal experience, these stories taught both clinical (eg, operative technique, decision making, error identification) and programmatic (eg, resource management, professionalism) topics. Narrative stories are used frequently and intuitively by physicians to emphasize a variety of intraoperative teaching points. They socialize trainees in the culture of surgery and may represent an underrecognized approach to teaching the core competencies. More understanding is needed to maximize their potential. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Goldstein, Arthur W; Alpert, Sumner; Beede, William; Kovach, Karl
1949-01-01
In order to understand the operation and the interaction of jet-engine components during engine operation and to determine how component characteristics may be used to compute engine performance, a method to analyze and to estimate performance of such engines was devised and applied to the study of the characteristics of a research turbojet engine built for this investigation. An attempt was made to correlate turbine performance obtained from engine experiments with that obtained by the simpler procedure of separately calibrating the turbine with cold air as a driving fluid in order to investigate the applicability of component calibration. The system of analysis was also applied to prediction of the engine and component performance with assumed modifications of the burner and bearing characteristics, to prediction of component and engine operation during engine acceleration, and to estimates of the performance of the engine and the components when the exhaust gas was used to drive a power turbine.
NASA Astrophysics Data System (ADS)
Xu, C.; Gao, Z. W.; Lan, S.; Guo, H. X.; Gong, M. C.
2018-01-01
In the paper, existing research and operating experience was summarized. On the basis, the particularity of oil-paper insulation operation condition for converter transformer was combined for studying the influence of temperature on oil-paper insulation field intensity distribution of converter transformers under different AC contents within wide temperature scope (-40°C∼105°C). The law of temperature gradients on space charge accumulation was analyzed. The breakdown or flashover characteristics of typical oil-paper compound insulation structure under the action of DC, AC and AC-DC superposition voltage at different temperatures were explored. The design principles of converter transformer oil-paper insulation structures in alpine region was proposed. The principle was adjusted and optimized properly according to the operation temperature scope and withstood AC-DC proportion. The reliability of transformer operation was improved on the one hand, and the insulating medium can be rationally utilized for reducing the manufacturing cost of the transformer on the other hand.
Dynamic Response during PEM Fuel Cell Loading-up
Pei, Pucheng; Yuan, Xing; Gou, Jun; Li, Pengcheng
2009-01-01
A study on the effects of controlling and operating parameters for a Proton Exchange Membrane (PEM) fuel cell on the dynamic phenomena during the loading-up process is presented. The effect of the four parameters of load-up amplitudes and rates, operating pressures and current levels on gas supply or even starvation in the flow field is analyzed based accordingly on the transient characteristics of current output and voltage. Experiments are carried out in a single fuel cell with an active area of 285 cm2. The results show that increasing the loading-up amplitude can inevitably increase the possibility of gas starvation in channels when a constant flow rate has been set for the cathode; With a higher operating pressure, the dynamic performance will be improved and gas starvations can be relieved. The transient gas supply in the flow channel during two loading-up mode has also been discussed. The experimental results will be helpful for optimizing the control and operation strategies for PEM fuel cells in vehicles.
War stories: a qualitative analysis of narrative teaching strategies in the operating room
Hu, Yue-Yung; Peyre, Sarah E.; Arriaga, Alexander F.; Roth, Emilie M.; Corso, Katherine A.; Greenberg, Caprice C.
2015-01-01
BACKGROUND “War stories” are commonplace in surgical education, yet little is known about their purpose, construct, or use in the education of trainees. METHODS Ten complex operations were videotaped and audiotaped. Narrative stories were analyzed using grounded theory to identify emergent themes in both the types of stories being told and the teaching objectives they illustrated. RESULTS Twenty-four stories were identified in 9 of the 10 cases (mean, 2.4/case). They were brief (mean, 58 seconds), illustrative of multiple teaching points (mean, 1.5/story), and appeared throughout the operations. Anchored in personal experience, these stories taught both clinical (eg, operative technique, decision making, error identification) and programmatic (eg, resource management, professionalism) topics. CONCLUSIONS Narrative stories are used frequently and intuitively by physicians to emphasize a variety of intraoperative teaching points. They socialize trainees in the culture of surgery and may represent an underrecognized approach to teaching the core competencies. More understanding is needed to maximize their potential. PMID:22088266
Scientific uses of the space shuttle
NASA Technical Reports Server (NTRS)
1974-01-01
A survey was conducted to determine the possible missions which could be accomplished by the space shuttle. The areas of scientific endeavor which were considered are as follows: (1) atmospheric and space physics, (2) high energy astrophysics, (3) infrared astronomy, (4) optical and ultraviolet astronomy, (5) solar physics, (6) life sciences, and (7) planetary exploration. Specific projects to be conducted in these broader areas are defined. The modes of operation of the space shuttle are analyzed. Instruments and equipment required for conducting the experiments are identified.
Object classification for obstacle avoidance
NASA Astrophysics Data System (ADS)
Regensburger, Uwe; Graefe, Volker
1991-03-01
Object recognition is necessary for any mobile robot operating autonomously in the real world. This paper discusses an object classifier based on a 2-D object model. Obstacle candidates are tracked and analyzed false alarms generated by the object detector are recognized and rejected. The methods have been implemented on a multi-processor system and tested in real-world experiments. They work reliably under favorable conditions but sometimes problems occur e. g. when objects contain many features (edges) or move in front of structured background.
High Frequency Analyzer (HFA) of Plasma Wave Experiment (PWE) onboard the Arase spacecraft
NASA Astrophysics Data System (ADS)
Kumamoto, Atsushi; Tsuchiya, Fuminori; Kasahara, Yoshiya; Kasaba, Yasumasa; Kojima, Hirotsugu; Yagitani, Satoshi; Ishisaka, Keigo; Imachi, Tomohiko; Ozaki, Mitsunori; Matsuda, Shoya; Shoji, Masafumi; Matsuoka, Aayako; Katoh, Yuto; Miyoshi, Yoshizumi; Obara, Takahiro
2018-05-01
The High Frequency Analyzer (HFA) is a subsystem of the Plasma Wave Experiment onboard the Arase (ERG) spacecraft. The main purposes of the HFA include (1) determining the electron number density around the spacecraft from observations of upper hybrid resonance (UHR) waves, (2) measuring the electromagnetic field component of whistler-mode chorus in a frequency range above 20 kHz, and (3) observing radio and plasma waves excited in the storm-time magnetosphere. Two components of AC electric fields detected by Wire Probe Antenna and one component of AC magnetic fields detected by Magnetic Search Coils are fed to the HFA. By applying analog and digital signal processing in the HFA, the spectrograms of two electric fields (EE mode) or one electric field and one magnetic field (EB mode) in a frequency range from 10 kHz to 10 MHz are obtained at an interval of 8 s. For the observation of plasmapause, the HFA can also be operated in PP (plasmapause) mode, in which spectrograms of one electric field component below 1 MHz are obtained at an interval of 1 s. In the initial HFA operations from January to July, 2017, the following results are obtained: (1) UHR waves, auroral kilometric radiation (AKR), whistler-mode chorus, electrostatic electron cyclotron harmonic waves, and nonthermal terrestrial continuum radiation were observed by the HFA in geomagnetically quiet and disturbed conditions. (2) In the test operations of the polarization observations on June 10, 2017, the fundamental R-X and L-O mode AKR and the second-harmonic R-X mode AKR from different sources in the northern polar region were observed. (3) The semiautomatic UHR frequency identification by the computer and a human operator was applied to the HFA spectrograms. In the identification by the computer, we used an algorithm for narrowing down the candidates of UHR frequency by checking intensity and bandwidth. Then, the identified UHR frequency by the computer was checked and corrected if needed by the human operator. Electron number density derived from the determined UHR frequency will be useful for the investigation of the storm-time evolution of the plasmasphere and topside ionosphere.[Figure not available: see fulltext.
Ehanire, Tosan; Singhal, Dhruv; Mast, Bruce; Leyngold, Mark
2018-01-24
Microsurgery is performed using either the operating microscope or loupe magnification. Use of the operating microscope is considered the "criterion standard"; however, loupes are emerging as a safe and reliable technique to perform microsurgery. The purpose of this study was to analyze the safety of microsurgery under loupe magnification compared with the microscope. Previous studies discussing the safety of loupe magnification during microsurgery have been published; however, this is the first study to compare free flap outcomes from 2 surgeons at the same institution, each using their respective technique. The outcomes were compared by retrospective chart review of 116 patients, and 148 microvascular free tissue transfers were performed between January 1, 2013, and July 15, 2016, by 2 surgeons (D.S.) and (M.L.). Patients' demographics, free flap failure rate, and other surgical complications were analyzed. Statistical significance was determined by unpaired t test, and χ analysis was used to determine statistical significance in proportions between groups. Thirty-eight percent of flaps were performed under ×3.5 loupe magnification and 62% under the operating microscope. Most free flaps used were deep inferior epigastric perforator or muscle sparing transverse rectus abdominis flaps (52%) for breast reconstruction, remainder of free flaps included ALT, radial forearm, and latissimus dorsi for a variety of reconstructive applications. There was no significant difference between the loupes and microscope groups in intraoperative anastomotic revision rate (27% vs 17%), postoperative arterial or venous thrombosis (4.4% vs 2.6%, 5.4% vs 2.2%), flap loss (3.6% vs 2.2%), or median length of stay (6 days vs 6.5 days). The loupe magnification group had statistically significant shorter setup time (20 minutes, P < 0.01). Consistent with previously reported studies, we found no statistical difference in free flap outcomes and safety under loupe magnification compared with the operating microscope. This is the first study to demonstrate these findings with 2 microsurgeons both in their first 3 years in practice, with similar training and experience, operating at the same institution and given the same resources, each using either microscopes or loupes for microsurgery.
The Martian surface as imaged, sampled, and analyzed by the Viking landers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arvidson, R.E.; Gooding, J.L.; Moore, H.J.
1989-02-01
Data collected by two Viking landers are analyzed. Attention is given to the characteristics of the surface inferred from Lander imaging and meteorology data, physical and magnetic properties experiments, and both inorganic and organic analyses of Martian samples. Viking Lander 1 touched down on Chryse Planitia on July 20, 1976 and continued to operate for 2252 sols, until November 20, 1982. Lander 2 touched down about 6500 km away from Lander 1, on Utopia Planitia on September 3, 1976. The chemical compositions of sediments at the two landing sites are similar, suggesting an aeolian origin. The compositions suggest an iron-richmore » rock an are matched by various clays and salts. 89 refs.« less
Integrated Studies of Electric Propulsion Engines during Flights in the Earth's Ionosphere
NASA Astrophysics Data System (ADS)
Marov, M. Ya.; Filatyev, A. S.
2018-03-01
Fifty years ago, on October 1, 1966, the first Yantar satellite laboratory with a gas plasma-ion electric propulsion was launched into orbit as part of the Yantar Soviet space program. In 1966-1971, the program launched a total of four laboratories with thrusters operating on argon, nitrogen, and air with jet velocities of 40, 120, and 140 km/s, respectively. These space experiments were the first to demonstrate the long-term stable operation of these thrusters, which exceed chemical rocket engines in specific impulse by an order of magnitude and provide effective jet charge compensation, under the conditions of a real flight at altitudes of 100-400 km. In this article, we have analyzed the potential modern applications of the scientific results obtained by the Yantar space program for the development of air-breathing electric propulsion that ensure the longterm operation of spacecraft in very low orbits.
[The use of staplers for intestinal anastomosis in newborns].
Kozlov, Iu A; Novozhilov, V A; Podkamenev, A V; Veber, I N
2013-01-01
The comparative experience of mechanical and manual intestinal anastomoses in newborns was analyzed. The main group (mechanical suture) consisted of 23 patients; the group of control consisted of 21 little patients. The mechanical intestinal suture was performed with the use of linear endoscopic stapler with 2.5 mm high staples. There were no differences in age and body weight between the two groups. The mean operative time was 77.4 min for the 1st group, whereas for the 2nd group it was 56.4 min. There were no significant difference in time before enteral feeding after the operation - 6.7 days on average. The hospital stay time was also identical (13.3 vs. 14.1 days). Postoperative period was uncomplicated in both groups. Thus, the use of mechanical stapler for intestinal anastomosis allows shorten the operative time, though preserving the same results of hospital stay and enteral feeding beginning.
Participation of surgical residents in operations: challenging a common classification.
Bezemer, Jeff; Cope, Alexandra; Faiz, Omar; Kneebone, Roger
2012-09-01
One important form of surgical training for residents is their participation in actual operations, for instance as an assistant or supervised surgeon. The aim of this study was to explore what participation in operations entails and how it might be described and analyzed. A qualitative study was undertaken in a major teaching hospital in London. A total of 122 general surgical operations were observed. A subsample of 14 laparoscopic cholecystectomies involving one or more residents was analyzed in detail. Audio and video recordings of eight operations were transcribed and analyzed linguistically. The degree of participation of trainees frequently shifted as the operation progressed to the next stage. Participation also varied within each stage. When trainees operated under supervision, the supervisors constantly adjusted their degree of control over the resident's operative maneuvers. Classifications such as "assistant" and "supervised surgeon" describing a trainee's overall participation in an operation potentially misrepresent the varying involvement of resident and supervisor. Video recordings provide a useful alternative for documenting and analyzing actual participation in operations.
Improvement of the extravehicular activity suit for the MIR orbiting station program.
Severin, G; Abramov, I; Svertshek, V; Stoklitsky, A
1996-09-01
Since 1977, EVA suits of the semi-rigid type have been used to support sorties from Russian orbiting stations. Currently, within the MIR station program, the Orlan-DMA, the latest modification of the Orlan semi-rigid EVA suit is used by crewmembers. Quite some experience has been gained by Russia in operations of the Orlan type suits. It has proved the advantages of the EVA suit of a semi-rigid configuration, featuring donning/doffing through a hinged backpack door with a built-in life support system. Meanwhile there were some wishes and comments from the crewmembers addressed to the enclosure design and some LSS components. Currently a number of ways and methods are being developed to improve operational characteristics of the suit as well as to enhance its reliability and lifetime. The forthcoming EVAs to be performed by the STS-MIR crewmembers and future EVAs from the common airlock of the International Space Station Alpha make implementation of the planned improvements even more consistent. The paper analyzes the experience gained in the Orlan-DMA operation and discusses planned improvements in light of the forthcoming activities. In particular the Orlan enhancement program is aimed to make the donning/doffing easier, enhance enclosure mobility, improve the condensate removal unit, increase the CCC (Contamination Control Cartridge) operation time and simplify the onboard subsystem design concept.
An operational amplifier B1404UD1A-1 in the patch-clamp current-to-voltage converter.
Korzun, A M; Rozinov, S V; Abashin, G I
1997-01-01
The applicability of the home-made operational amplifier B1404UD1A-1 in a patch-clamp current-to-voltage converter was analyzed. Its parameters (background noise, input bias current, and gain-bandwidth product) were estimated. Schematic solutions and practical recommendations for the use of this amplifier in a current-to-voltage converter were given. Based on the background noise and frequency parameters of the converter, we found that this device can be used for measuring ion channel currents with a high sensitivity and within a broad frequency range (0.055 pA, to 1 kHz; 0.4 pA, to 10 kHz). An example of the converter application in experiments is given.
Remote Control and Monitoring of VLBI Experiments by Smartphones
NASA Astrophysics Data System (ADS)
Ruztort, C. H.; Hase, H.; Zapata, O.; Pedreros, F.
2012-12-01
For the remote control and monitoring of VLBI operations, we developed a software optimized for smartphones. This is a new tool based on a client-server architecture with a Web interface optimized for smartphone screens and cellphone networks. The server uses variables of the Field System and its station specific parameters stored in the shared memory. The client running on the smartphone by a Web interface analyzes and visualizes the current status of the radio telescope, receiver, schedule, and recorder. In addition, it allows commands to be sent remotely to the Field System computer and displays the log entries. The user has full access to the entire operation process, which is important in emergency cases. The software also integrates a webcam interface.
Neutron Particle Effects on a Quad-Redundant Flight Control Computer
NASA Technical Reports Server (NTRS)
Eure, Kenneth; Belcastro, Celeste M.; Gray, W Steven; Gonzalex, Oscar
2003-01-01
This paper describes a single-event upset experiment performed at the Los Alamos National Laboratory. A closed-loop control system consisting of a Quad-Redundant Flight Control Computer (FCC) and a B737 simulator was operated while the FCC was exposed to a neutron beam. The purpose of this test was to analyze the effects of neutron bombardment on avionics control systems operating at altitudes where neutron strikes are probable. The neutron energy spectrum produced at the Los Alamos National Laboratory is similar in shape to the spectrum of atmospheric neutrons but much more intense. The higher intensity results in accelerated life tests that are representative of the actual neutron radiation that a FCC may receive over a period of years.
NASA Technical Reports Server (NTRS)
Marks, D. A.; Gendiellee, R. E.; Kelly, T. M.; Giovannello, M. A.
1974-01-01
Ground processing and operation activities for selected automated and sortie payloads are evaluated. Functional flow activities are expanded to identify payload launch site facility and support requirements. Payload definitions are analyzed from the launch site ground processing viewpoint and then processed through the expanded functional flow activities. The requirements generated from the evaluation are compared with those contained in the data sheets. The following payloads were included in the evaluation: Long Duration Exposure Facility; Life Sciences Shuttle Laboratory; Biomedical Experiments Scientific Satellite; Dedicated Solar Sortie Mission; Magnetic Spectrometer; and Mariner Jupiter Orbiter. The expanded functional flow activities and descriptions for the automated and sortie payloads at the launch site are presented.
NASA Astrophysics Data System (ADS)
Yerizon; Jazwinarti; Yarman
2018-01-01
Students have difficulties experience in the course Introduction to Operational Research (PRO). The purpose of this study is to analyze the requirement of students in the developing lecturing materials PRO based Problem Based Learning which is valid, practice, and effective. Lecture materials are developed based on Plomp’s model. The development process of this device consists of 3 phases: front-end analysis/preliminary research, development/prototype phase and assessment phase. Preliminary analysis was obtained by observation and interview. From the research, it is found that students need the student’s worksheet (LKM) for several reasons: 1) no LKM available, 2) presentation of subject not yet based on real problem, 3) experiencing difficulties from current learning source.
Medical evaluations on the KC-135 1990 flight report summary
NASA Technical Reports Server (NTRS)
Lloyd, Charles W.; Guess, Terrell M.; Whiting, Charles W.; Doarn, Charles R.
1991-01-01
The medical investigations completed on the KC-135 during FY 1990 in support of the development of the Health Maintenance Facility and Medical Operations are discussed. The experiments are comprised of engineering evaluations of medical hardware and medical procedures. The investigating teams are made up of both medical and engineering personnel responsible for the development of medical hardware and medical operations. The hardware evaluated includes dental equipment, a coagulation analyzer, selected pharmaceutical aerosol devices, a prototype air/fluid separator, a prototype packaging and stowage system for medical supplies, a microliter metering system, and a workstation for minor surgical procedures. The results of these engineering evaluations will be used in the design of fleet hardware as well as to identify hardware specific training requirements.
Hua, Chengcheng; Wang, Hong; Wang, Hong; Lu, Shaowen; Liu, Chong; Khalid, Syed Madiha
2018-04-11
Functional brain network (FBN) has become very popular to analyze the interaction between cortical regions in the last decade. But researchers always spend a long time to search the best way to compute FBN for their specific studies. The purpose of this study is to detect the proficiency of operators during their mineral grinding process controlling based on FBN. To save the search time, a novel semi-data-driven method of computing functional brain connection based on stacked autoencoder (BCSAE) is proposed in this paper. This method uses stacked autoencoder (SAE) to encode the multi-channel EEG data into codes and then computes the dissimilarity between the codes from every pair of electrodes to build FBN. The highlight of this method is that the SAE has a multi-layered structure and is semi-supervised, which means it can dig deeper information and generate better features. Then an experiment was performed, the EEG of the operators were collected while they were operating and analyzed to detect their proficiency. The results show that the BCSAE method generated more number of separable features with less redundancy, and the average accuracy of classification (96.18%) is higher than that of the control methods: PLV (92.19%) and PLI (78.39%).
Aporowicz, Michał; Kaliszewski, Krzysztof; Bolanowski, Marek
2016-01-01
Introduction Surgical treatment of thyroid gland diseases is associated with the possibility of severe complications. The most dangerous of them is bleeding. Current studies focus on its risk factors, rather than reoperation-related consequences. Material and methods We analyzed 7805 thyroid operations performed from 1996 to 2014 in the Clinic of General, Gastroenterological and Endocrine Surgery of Wroclaw Medical University. Typical risk factors, symptoms and consequences of bleeding were analyzed. Results Among operated patients 88.2% were female and 11.8% male. Bleeding occurred in 84 (1.08%) patients. Sex (p = 0.006), preoperative thyroid pathology (p = 0.03), and type of operation (p < 0.001) are significant risk factors for bleeding, while retrosternal goiter and surgeon’s experience are not. Risk of bleeding is highest in the case of male sex, toxic goiter and total resection of the thyroid gland. Most reoperations took place within 6 h. In 88.8% of cases of this kind of complication the surgeon indicated the exact source of bleeding; most commonly it was the neck muscles, skin and subcutaneous tissue, or the thyroid stump. Three patients required a second reoperation, 24 suffered further complications, and 8 required transfer to the Intensive Care Unit (ICU). Cardiac arrest occurred in 3 patients and 2 suffered bilateral vocal cord palsy. Conclusions Bleeding after thyroid operations is a direct life threat that requires immediate intervention. As a result death may occur, half of patients suffer other complications and some require intensive care. The risk is highest in the case of male sex, toxic goiter and total resection of the thyroid gland. Each patient after thyroid surgery needs to be closely observed. An operating theatre and ICU should be available at all times. PMID:29593806
ACGME case logs: Surgery resident experience in operative trauma for two decades
Drake, Frederick Thurston; Van Eaton, Erik G.; Huntington, Ciara R.; Jurkovich, Gregory J.; Aarabi, Shahram; Gow, Kenneth W.
2014-01-01
BACKGROUND Surgery resident education is based on experiential training, which is influenced by changes in clinical management strategies, technical and technologic advances, and administrative regulations. Trauma care has been exposed to each of these factors, prompting concerns about resident experience in operative trauma. The current study analyzed the reported volume of operative trauma for the last two decades; to our knowledge, this is the first evaluation of nationwide trends during such an extended time line. METHODS The Accreditation Council for Graduate Medical Education (ACGME) database of operative logs was queried from academic year (AY) 1989–1990 to 2009–2010 to identify shifts in trauma operative experience. Annual case log data for each cohort of graduating surgery residents were combined into approximately 5-year blocks, designated Period I (AY1989–1990 to AY1993–1994), Period II (AY1994–1995 to AY1998–1999), Period III (AY1999–2000 to AY2002–2003), and Period IV (AY2003–2004 to AY2009–2010). The latter two periods were delineated by the year in which duty hour restrictions were implemented. RESULTS Overall general surgery caseload increased from Period I to Period II (p < 0.001), remained stable from Period II to Period III, and decreased from Period III to Period IV (p < 0.001). However, for ACGME-designated trauma cases, there were significant declines from Period I to Period II (75.5 vs. 54.5 cases, p < 0.001) and Period II to Period III (54.5 vs. 39.3 cases, p < 0.001) but no difference between Period III and Period IV (39.3 vs. 39.4 cases). Graduating residents in Period I performed, on average, 31 intra-abdominal trauma operations, including approximately five spleen and four liver operations. Residents in Period IV performed 17 intra-abdominal trauma operations, including three spleen and approximately two liver operations. CONCLUSION Recent general surgery trainees perform fewer trauma operations than previous trainees. The majority of this decline occurred before implementation of work-hour restrictions. Although these changes reflect concurrent changes in management of trauma, surgical educators must meet the challenge of training residents in procedures less frequently performed. LEVEL OF EVIDENCE Epidemiologic study, level III; therapeutic study, level IV. PMID:23188243
Morimoto, Akiko; Ueda, Yutaka; Yokoi, Takeshi; Tokizawa, Yuki; Yoshino, Kiyoshi; Fujita, Masami; Kimura, Toshihiro; Kobayashi, Eiji; Matsuzaki, Shinya; Egawa-Takata, Tomomi; Sawada, Kenjiro; Tsutsui, Tateki; Kimura, Tadashi
2014-07-01
To analyze clinical characteristics of venous thromboembolisms (VTE) in gynecological malignancies, and to find a cost-effective prophylaxis procedure for post-operative VTE. We analyzed clinical characteristics of 751 patients who underwent definitive surgery for gynecologic malignancies, and cost-effectiveness of VTE prophylaxis. VTE was diagnosed preoperatively in 4.5% of ovarian cancer cases, more frequently than any other type (p<0.005). Older age and greater length of operation were independent risk factors for postoperative VTE. To prevent eight VTEs in 738 malignant cases, which occurred during day 2 to 10, $617,783, $726,185, or $994,222 were necessary for continuous VTE prophylaxis, using either unfractionated heparin (UFH), low-molecular weight heparin or fondaparinux, respectively. A strategy which might be cost-effective for post-surgical management of gynecological malignances is use of UFH three times combined with graduated compression stockings and intermittent pneumatic compression, thorough SpO2 monitoring, and perioperative measurements of the circumference of both sides of thighs and calves. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
McKinnon, Adam D; Ozanne-Smith, Joan; Pope, Rodney
2009-05-01
Injury prevention guided by robust injury surveillance systems (ISS's) can effectively reduce military injury rates, but ISS's depend on human interaction. This study examined experiences and requirements of key users of the Australian Defence Force (ADF) ISS to determine whether the operation of the ISS was optimal, whether there were any shortcomings, and if so, how these shortcomings might be addressed. Semistructured interviews were conducted with 18 Australian Defence Department participants located throughout Australia. Grounded theory methods were used to analyze data by developing an understanding of processes and social phenomena related to injury surveillance systems within the military context. Interviews were recorded and professionally transcribed and information contained in the transcripts was analyzed using NVivo. Key themes relating to the components of an injury surveillance system were identified from the analysis. A range of processes and sociocultural factors influence the utility of military ISS's. These are discussed in detail and should be considered in the future design and operation of military ISS's to facilitate optimal outcomes for injury prevention.
Investigation of a GaAlAs Mach-Zehnder electro-optic modulator. M.S. Thesis. Final Contractor Report
NASA Technical Reports Server (NTRS)
Materna, David M.
1987-01-01
A GaAs modulator operating at 0.78 to 0.88 micron wavelength has the potential to be integrated with a GaAs/GaAlAs laser diode for an integrated fiber-optic transmitter. A travelling-wave Mach-Zehnder modulator using the electro-optic effect of GaAs and operating at a wavelength of 0.82 microns has been investigated for the first time. A four layer Strip-loaded ridge optical waveguide has been analyzed using the effective index method and single mode waveguides have been designed. The electro-optic effect of GaAs has also been analyzed and a modulator using the geometry producing the maximum phase shift has been designed. A coplanar transmission line structure is used in an effort to tap the potentially higher bandwidth of travelling-wave electrodes. The modulator bandwidth has been calculated at 11.95 GHz with a required drive power of 2.335 Watts for full intensity modulation. Finally, some preliminary experiments were performed to characterize a fabrication process for the modulator.
Robotic resections in hepatobiliary oncology - initial experience with Xi da Vinci system in India.
Chandarana, M; Patkar, S; Tamhankar, A; Garg, S; Bhandare, M; Goel, M
2017-01-01
Minimal invasive surgery has proven its advantages over open surgeries in the perioperative period. Food and Drug Administration approved da Vinci robot in 2000. The latest version, da Vinci Xi system has a mobile tower-based robot with several modifications to improve the functionality, versatility, and operative ease. None of the centers have reported exclusively on hepatobiliary oncology using the da Vinci Xi system. We report our initial experience. To study the feasibility, advantages, and discuss the operative technique of da Vinci Xi system in hepatobiliary oncology. Data were analyzed retrospectively from a prospectively maintained database from June 2015 to October 2016. Twenty-five patients with suspected or proven hepatobiliary malignancies were operated. Total robotic technique using da Vinci Xi system was used. Demographic details and perioperative outcomes were noted. Of the 25 surgeries, 14 patients had a suspected gallbladder malignancy, 11 patients had primary or metastatic liver tumor. Median age was 53 years. The average duration of surgery was 225 min with a median blood loss 150 ml. The median postoperative stay was 4 days. The median nodal yield for radical cholecystectomy was seven. Five patients required conversion. Two of these developed postoperative morbidity. Robotic surgery for hepatobiliary oncology is feasible and can be performed safely in experienced hands. Increasing experience in this field may equal or even prove advantageous over conventional or laparoscopic approach in future. A cautious approach with judicious patient selection is the key to establishing robotic surgery as a standard surgical approach.
Duran-Sindreu, Fernando; Calvo, Carmen; Basilio, Juan; Abella, Fransesc; Ali, Akram; Roig, Miguel; Olivieri, Juan-Gonzalo
2017-01-01
Background The aim of the present study was to compare clinically the incidence of postoperative pain after endodontic treatment using the Reciproc System, taking into account the operator’s experience. Material and Methods One hundred patients scheduled for routine endodontic treatment were enrolled in this study. Endodontic treatment was carried out in a single visit by undergraduate and postgraduate students. The chemomechanical preparation of root canals was performed with Reciproc instruments. Pretreatment and postoperative pain was recorded using a visual analogue scale (VAS). Postoperative pain and the need for analgesic consumption were assessed at 4, 8, 16, 24, 48 and 72 hours post-treatment. The data were analyzed using the Mann–Whitney U and Chi-Square test, and the significance was set at P<0.05. Results The mean value of pain after root canal treatment was 1.13±1.94 and 1.91±2.07 on a VAS between 0 and 10 in treatments performed by undergraduate and postgraduate students, respectively. There was a significant difference in the incidence of postoperative pain between the two groups (P<0.05). Conclusions The prevalence of postoperative pain was high in the treatments performed by postgraduate students in comparison with undergraduate students. This suggests that operator experience has an influence on the prevalence of postoperative pain after root canal treatment. Key words:Post-endodontic pain, root canal treatment, reciprocating systems, Expert operators Inexperienced operators. PMID:28828152
Surface Operations Systems Improve Airport Efficiency
NASA Technical Reports Server (NTRS)
2009-01-01
With Small Business Innovation Research (SBIR) contracts from Ames Research Center, Mosaic ATM of Leesburg, Virginia created software to analyze surface operations at airports. Surface surveillance systems, which report locations every second for thousands of air and ground vehicles, generate massive amounts of data, making gathering and analyzing this information difficult. Mosaic?s Surface Operations Data Analysis and Adaptation (SODAA) tool is an off-line support tool that can analyze how well the airport surface operation is working and can help redesign procedures to improve operations. SODAA helps researchers pinpoint trends and correlations in vast amounts of recorded airport operations data.
Currie, B M; Getrajdman, G I; Covey, A M; Alago, W; Erinjeri, J P; Maybody, M; Boas, F E
2018-04-28
To compare the technical success and complication rates of push versus pull gastrostomy tubes in cancer patients, and to examine their dependence on operator experience. A retrospective review was performed of 304 cancer patients (170 men, 134 women; mean age 60.3±12.6 [SD], range: 19-102 years) referred for primary gastrostomy tube placement, 88 (29%) of whom had a previously unsuccessful attempt at percutaneous endoscopic gastrostomy (PEG) placement. Analyzed variables included method of insertion (push versus pull), indication for gastrostomy, technical success, operator experience, and procedure-related complications within 30 days of placement. Gastrostomy tubes were placed for feeding in 189 patients and palliative decompression in 115 patients. Technical success was 91%: 78% after endoscopy had previously been unsuccessful and 97% when excluding failures associated with prior endoscopy. In the first 30 days, there were 29 minor complications (17.2%) associated with push gastrostomies, and only 8 minor complications (7.5%) with pull gastrostomies (P<0.05). There was no significant difference in major complications (push gastrostomy 5.3%, pull gastrostomy 5.6%). For decompressive gastrostomy tubes, the pull technique resulted in lower rates of both minor and major complications. There was no difference in complications or technical success rates for more versus less experienced operators. Pull gastrostomy tube placement had a lower rate of complications than push gastrostomy tube placement, especially when the indication was decompression. The technical success rate was high, even after a failed attempt at endoscopic placement. Both the rates of success and complications were independent of operator experience. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Uniportal video assisted thoracoscopic lobectomy: primary experience from an Eastern center.
Feng, Mingxiang; Shen, Yaxing; Wang, Hao; Tan, Lijie; Mao, Xuping; Liu, Yi; Wang, Qun
2014-12-01
Uniportal video-assisted thoracoscopic surgery (VATS) lobectomy is an emerging technique for the surgical resection of non-small cell lung cancer (NSCLC). Besides its wide debates on safety and efficacy throughout the world, there were few report on uniportal VATS from the Eastern countries. In this article, we summarized our primary experience on uniportal VATS lobectomy in an Eastern center. From October 2013 till February 2014, 54 consecutive uniportal VATS lobectomy were performed in the Department of Thoracic Surgery, Zhongshan Hospital of Fudan University. Patients' clinical features and operative details were recorded. Post-operatively, the morbidity and mortality were recorded to analyze the safety and efficacy of uniportal VATS lobectomy for NSCLCs. Among the 54 planned uniportal VATS lobectomy, there was one conversion to mini-thoracotomy due to lymph node sticking. Extra ports were required in two patients. The uniportal VATS lobectomy was achieved in 51 out of 54 patients (94.4%). The average operation duration was 122.2±37.5 min (90-160 min). The average volume of estimated blood loss during the operation was 88.8±47.1 mL (50-200 mL). The mean chest tube duration and hospital stay were 3.2±1.9 days and 4.6±2.0 days, respectively. There was no postoperative mortality in this study. Two patients suffered from prolonged air leakage (5 and 7 days), and one atrial fibrillation was observed in this cohort. Based on our primary experience, uniportal VATS lobectomy is a safe and effective procedure for the surgical resection of NSCLCs. The surgical refinements and instrumental improvements would facilitate the technique. Further studies based on larger population are required to determine its benefits towards patients with NSCLCs.
Enhanced Flight Termination System (EFTS): Flight Demonstration and Results
NASA Technical Reports Server (NTRS)
Tow, David; Arce, Dennis
2008-01-01
The Enhanced Flight Termination System (EFTS) program was initiated and propelled due to the inadvertent terminations of Global Hawk and the Strategic Target System and the NASA Inspector General's assessment letter and recommendations regarding the exploration of low-cost, lightweight space COMSEC for FTS. Additionally, the standard analog and high alphabet systems most commonly used in FTS are secure, but not encrypted. A study group was initiated to select and document a robust, affordable, reliable technology that provides encrypted FTS capability. A flight demonstration was conducted to gain experience using EFTS in an operational environment, provide confidence in the use of the EFTS components, integrate EFTS into an existing range infrastructure to demonstrate the scalability of system components, to provide a command controller that generated the EFTS waveform using an existing range infrastructure, and to provide a report documenting the results of the demonstration. The primary goal of the demonstration was to obtain operational experience with EFTS. Areas of operational experience include: mission planning, pre-flight configuration and testing, mission monitoring and recording, vehicle termination, developing mission procedures. and post mission data reduction and other post mission activities. An Advanced Medium-Range Air-to-Air Missile (AMRAAM) was selected to support the EFTS demonstration due to interest in future use of EFTS by the AMRAAM program, familiarity of EFTS by range personnel, and the availability of existing operational environment to support EFTS testing with available program funding. For demonstration purposes, the AMRAAM was successfully terminated using an EFTS receiver and successfully demonstrating EFTS. The EFTS monitoring software with spectrum analyzer and digital graphical display of aircraft, missile, and target were also demonstrated.
Carrasco, Alejandro; Jalali, Elnaz; Dhingra, Ajay; Lurie, Alan; Yadav, Sumit; Tadinada, Aditya
2017-06-01
The aim of this study was to compare a medical-grade PACS (picture archiving and communication system) monitor, a consumer-grade monitor, a laptop computer, and a tablet computer for linear measurements of height and width for specific implant sites in the posterior maxilla and mandible, along with visualization of the associated anatomical structures. Cone beam computed tomography (CBCT) scans were evaluated. The images were reviewed using PACS-LCD monitor, consumer-grade LCD monitor using CB-Works software, a 13″ MacBook Pro, and an iPad 4 using OsiriX DICOM reader software. The operators had to identify anatomical structures in each display using a 2-point scale. User experience between PACS and iPad was also evaluated by means of a questionnaire. The measurements were very similar for each device. P-values were all greater than 0.05, indicating no significant difference between the monitors for each measurement. The intraoperator reliability was very high. The user experience was similar in each category with the most significant difference regarding the portability where the PACS display received the lowest score and the iPad received the highest score. The iPad with retina display was comparable with the medical-grade monitor, producing similar measurements and image visualization, and thus providing an inexpensive, portable, and reliable screen to analyze CBCT images in the operating room during the implant surgery.
NASA Astrophysics Data System (ADS)
An, Li-sha; Liu, Chun-jiao; Liu, Ying-wen
2018-05-01
In the polysilicon chemical vapor deposition reactor, the operating parameters are complex to affect the polysilicon's output. Therefore, it is very important to address the coupling problem of multiple parameters and solve the optimization in a computationally efficient manner. Here, we adopted Response Surface Methodology (RSM) to analyze the complex coupling effects of different operating parameters on silicon deposition rate (R) and further achieve effective optimization of the silicon CVD system. Based on finite numerical experiments, an accurate RSM regression model is obtained and applied to predict the R with different operating parameters, including temperature (T), pressure (P), inlet velocity (V), and inlet mole fraction of H2 (M). The analysis of variance is conducted to describe the rationality of regression model and examine the statistical significance of each factor. Consequently, the optimum combination of operating parameters for the silicon CVD reactor is: T = 1400 K, P = 3.82 atm, V = 3.41 m/s, M = 0.91. The validation tests and optimum solution show that the results are in good agreement with those from CFD model and the deviations of the predicted values are less than 4.19%. This work provides a theoretical guidance to operate the polysilicon CVD process.
Subaru FATS (fault tracking system)
NASA Astrophysics Data System (ADS)
Winegar, Tom W.; Noumaru, Junichi
2000-07-01
The Subaru Telescope requires a fault tracking system to record the problems and questions that staff experience during their work, and the solutions provided by technical experts to these problems and questions. The system records each fault and routes it to a pre-selected 'solution-provider' for each type of fault. The solution provider analyzes the fault and writes a solution that is routed back to the fault reporter and recorded in a 'knowledge-base' for future reference. The specifications of our fault tracking system were unique. (1) Dual language capacity -- Our staff speak both English and Japanese. Our contractors speak Japanese. (2) Heterogeneous computers -- Our computer workstations are a mixture of SPARCstations, Macintosh and Windows computers. (3) Integration with prime contractors -- Mitsubishi and Fujitsu are primary contractors in the construction of the telescope. In many cases, our 'experts' are our contractors. (4) Operator scheduling -- Our operators spend 50% of their work-month operating the telescope, the other 50% is spent working day shift at the base facility in Hilo, or day shift at the summit. We plan for 8 operators, with a frequent rotation. We need to keep all operators informed on the current status of all faults, no matter the operator's location.
Kim, H-I; Park, M S; Song, K J; Woo, Y; Hyung, W J
2014-10-01
The learning curve of robotic gastrectomy has not yet been evaluated in comparison with the laparoscopic approach. We compared the learning curves of robotic gastrectomy and laparoscopic gastrectomy based on operation time and surgical success. We analyzed 172 robotic and 481 laparoscopic distal gastrectomies performed by single surgeon from May 2003 to April 2009. The operation time was analyzed using a moving average and non-linear regression analysis. Surgical success was evaluated by a cumulative sum plot with a target failure rate of 10%. Surgical failure was defined as laparoscopic or open conversion, insufficient lymph node harvest for staging, resection margin involvement, postoperative morbidity, and mortality. Moving average and non-linear regression analyses indicated stable state for operation time at 95 and 121 cases in robotic gastrectomy, and 270 and 262 cases in laparoscopic gastrectomy, respectively. The cumulative sum plot identified no cut-off point for surgical success in robotic gastrectomy and 80 cases in laparoscopic gastrectomy. Excluding the initial 148 laparoscopic gastrectomies that were performed before the first robotic gastrectomy, the two groups showed similar number of cases to reach steady state in operation time, and showed no cut-off point in analysis of surgical success. The experience of laparoscopic surgery could affect the learning process of robotic gastrectomy. An experienced laparoscopic surgeon requires fewer cases of robotic gastrectomy to reach steady state. Moreover, the surgical outcomes of robotic gastrectomy were satisfactory. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
Ferrari, Luca; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
2013-02-01
During extracorporeal circulation (ECC), blood is periodically sampled and analyzed to maintain the blood-gas status of the patient within acceptable limits. This protocol has well-known drawbacks that may be overcome by continuous monitoring. We present the characterization of a new pH sensor for continuous monitoring in ECC. This monitoring device includes a disposable fluorescence-sensing element directly in contact with the blood, whose fluorescence intensity is strictly related to the pH of the blood. In vitro experiments show no significant difference between the blood gas analyzer values and the sensor readings; after proper calibration, it gives a correlation of R>0.9887, and measuring errors were lower than the 3% of the pH range of interest (RoI) with respect to a commercial blood gas analyzer. This performance has been confirmed also by simulating a moderate ipothermia condition, i.e., blood temperature 32°C, frequently used in cardiac surgery. In ex vivo experiments, performed with animal models, the sensor is continuously operated in an extracorporeal undiluted blood stream for a maximum of 11 h. It gives a correlation of R>0.9431, and a measuring error lower than the 3% of the pH RoI with respect to laboratory techniques.
NASA Technical Reports Server (NTRS)
Lanzerotti, L. J.; Gold, R. E.; Anderson, K. A.; Armstrong, T. P.; Lin, R. P.; Krimigis, S. M.; Pick, M.; Roelof, E. C.; Sarris, E. T.; Simnett, G. M.
1983-01-01
The Heliosphere Instrument for Spectral, Composition, and Anisotropy at Low Energies (HI-SCALE) designed to measure interplanetary ions and electrons is described. Ions and electrons are detected by five separate solid-state detector telescopes oriented to give complete pitch angle coverage from the spinning spacecraft. Ion elemental abundances are determined by a telescope using a thin front detector element in a three-element telescope. Experiment operation is controlled by a microprocessor-based data system. Inflight calibration is provided by radioactive sources mounted on closable telescope covers. Ion and electron spectral information is determined using broad-energy-range rate channels, and a pulse-height analyzer for more detailed spectra. The instrument weighs 5.775 kg and uses 4.0 W power.
Trends in bus transit operations, 1960-1974
DOT National Transportation Integrated Search
1977-01-01
This report analyzes the historical patterns of bus transit operations from 1960 to 1974 using data from 50 bus operations. Because of limitations on the available data, the analyzed data do not represent the universe of bus operations, nor is it a r...
Scex 3 and Electron Echo 7, a Comparison of Data from Two Rocket Experiments.
NASA Astrophysics Data System (ADS)
Bale, Stuart Douglas
Results from two separate active sounding rocket experiments are presented and discussed. The SCEX III sounding rocket (NASA 39.002 UE) and Electron Echo 7 (NASA 36.015) were both launched from the Poker Flat Research Range (65.1^circ N, 147.5^circ W) near Fairbanks, Alaska, on 1 February, 1990 and 9 February, 1988, respectively. Each payload was equipped with an electron accelerator to study both natural and beam-related plasma phenomena. Data from the SCEX III retarding potential analyzer (RPA) and 3805 A and 3914 A photometers show evidence of a plasma discharge process occurring concomitant with operation of the electron gun. This appears as an enhanced electron current, nonlinear with gun injection current, in the RPA. The photometers register a sharp increase in luminosity during full current electron injection. This luminosity is an indicator of the ionizing electron-neutral collisions which liberate electrons and lead to the cascade-type discharge process. These observations are used to attempt to infer the mechanism of electron acceleration which leads to the discharge process. Before the electron gun was activated, the SCEX III payload flew through a region of auroral activity as evidenced by ground-based all-sky TV and energetic particle flux in the forward payload RPA. During this time, low frequency (10 Hz) electrostatic waves were observed in the DC receivers and Langmuir probe instrument. This data is analyzed, with a cross-spectral technique, and an approximate wave number is inferred. Comparison with theory suggests that the observed wave is the electrostatic ion cyclotron mode (EIC) operating on a heavy ion species (NO or O _2). The Echo 7 nose payload, carrying a plasma wave receiver, was ejected upfield of the main electron gun -equipped payload. Data from the swept frequency analyzer experiment provide wave amplitudes, at frequencies up to 15 MHz, as a function of separation of the main and nose payloads. These observations, and the wave modes inferred, shed light on the wave generation region upfield from a beam-emitting ionospheric payload.
Freeway travel speed calculation model based on ETC transaction data.
Weng, Jiancheng; Yuan, Rongliang; Wang, Ru; Wang, Chang
2014-01-01
Real-time traffic flow operation condition of freeway gradually becomes the critical information for the freeway users and managers. In fact, electronic toll collection (ETC) transaction data effectively records operational information of vehicles on freeway, which provides a new method to estimate the travel speed of freeway. First, the paper analyzed the structure of ETC transaction data and presented the data preprocess procedure. Then, a dual-level travel speed calculation model was established under different levels of sample sizes. In order to ensure a sufficient sample size, ETC data of different enter-leave toll plazas pairs which contain more than one road segment were used to calculate the travel speed of every road segment. The reduction coefficient α and reliable weight θ for sample vehicle speed were introduced in the model. Finally, the model was verified by the special designed field experiments which were conducted on several freeways in Beijing at different time periods. The experiments results demonstrated that the average relative error was about 6.5% which means that the freeway travel speed could be estimated by the proposed model accurately. The proposed model is helpful to promote the level of the freeway operation monitoring and the freeway management, as well as to provide useful information for the freeway travelers.
Wei, Z G; Macwan, A P; Wieringa, P A
1998-06-01
In this paper we quantitatively model degree of automation (DofA) in supervisory control as a function of the number and nature of tasks to be performed by the operator and automation. This model uses a task weighting scheme in which weighting factors are obtained from task demand load, task mental load, and task effect on system performance. The computation of DofA is demonstrated using an experimental system. Based on controlled experiments using operators, analyses of the task effect on system performance, the prediction and assessment of task demand load, and the prediction of mental load were performed. Each experiment had a different DofA. The effect of a change in DofA on system performance and mental load was investigated. It was found that system performance became less sensitive to changes in DofA at higher levels of DofA. The experimental data showed that when the operator controlled a partly automated system, perceived mental load could be predicted from the task mental load for each task component, as calculated by analyzing a situation in which all tasks were manually controlled. Actual or potential applications of this research include a methodology to balance and optimize the automation of complex industrial systems.
Surgical management of gynecomastia: experience of a general surgery center
LONGHEU, A.; MEDAS, F.; CORRIAS, F.; FARRIS, S.; TATTI, A.; PISANO, G.; ERDAS, E.; CALÒ, P.G.
2016-01-01
Aim Gynecomastia is a common finding in male population of all ages. The aim of our study was to present our experience and goals in surgical treatment of gynecomastia. Patients and Methods Clinical records of patients affected by gynecomastia referred to our Department of Surgery between September 2008 and January 2015 were analyzed. 50 patients were included in this study. Results Gynecomastia was monolateral in 12 patients (24%) and bilateral in 38 (76%); idiopathic in 41 patients (82%) and secondary in 9 (18%). 39 patients (78%) underwent surgical operation under general anaesthesia, 11 (22%) under local anaesthesia. 3 patients (6%) presented recurrent disease. Webster technique was performed in 28 patients (56%), Davidson technique in 16 patients (32%); in 2 patients (4%) Pitanguy technique was performed and in 4 patients (8%) a mixed surgical technique was performed. Mean surgical time was 80.72±35.14 minutes, median postoperative stay was 1.46±0.88 days. 2 patients (4%) operated using Davidson technique developed a hematoma, 1 patient (2%) operated with the same technique developed hypertrophic scar. Conclusions Several surgical techniques are described for surgical correction of gynecomastia. If performed by skilled general surgeons surgical treatment of gynecomastia is safe and permits to reach satisfactory aesthetic results. PMID:27938530
40 CFR 86.524-78 - Carbon dioxide analyzer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operation. Adjust the analyzer to optimize performance. (2) Zero the carbon dioxide analyzer with either zero grade air or zero grade nitrogen. (3) Calibrate on each normally used operating range with carbon...
40 CFR 86.524-78 - Carbon dioxide analyzer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operation. Adjust the analyzer to optimize performance. (2) Zero the carbon dioxide analyzer with either zero grade air or zero grade nitrogen. (3) Calibrate on each normally used operating range with carbon...
40 CFR 86.524-78 - Carbon dioxide analyzer calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operation. Adjust the analyzer to optimize performance. (2) Zero the carbon dioxide analyzer with either zero grade air or zero grade nitrogen. (3) Calibrate on each normally used operating range with carbon...
Cold Atom Clock Test of Lorentz Invariance in the Matter Sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wolf, Peter; Chapelet, Frederic; Bize, Sebastien
2006-02-17
We report on a new experiment that tests for a violation of Lorentz invariance (LI), by searching for a dependence of atomic transition frequencies on the orientation of the spin of the involved states (Hughes-Drever type experiment). The atomic frequencies are measured using a laser cooled {sup 133}Cs atomic fountain clock, operating on a particular combination of Zeeman substates. We analyze the results within the framework of the Lorentz violating standard model extension (SME), where our experiment is sensitive to a largely unexplored region of the SME parameter space, corresponding to first measurements of four proton parameters and improvements bymore » 11 and 13 orders of magnitude on the determination of four others. In spite of the attained uncertainties, and of having extended the search into a new region of the SME, we still find no indication of LI violation.« less
Carotid artery phantom designment and simulation using field II
NASA Astrophysics Data System (ADS)
Lin, Yuan; Yang, Xin; Ding, Mingyue
2013-10-01
Carotid atherosclerosis is the major cause of ischemic stroke, a leading cause of mortality and disability. Morphology and structure features of carotid plaques are the keys to identify plaques and monitoring the disease. Manually segmentation on the ultrasonic images to get the best-fitted actual size of the carotid plaques based on physicians personal experience, namely "gold standard", is a important step in the study of plaque size. However, it is difficult to qualitatively measure the segmentation error caused by the operator's subjective factors. In order to reduce the subjective factors, and the uncertainty factors of quantification, the experiments in this paper were carried out. In this study, we firstly designed a carotid artery phantom, and then use three different beam-forming algorithms of medical ultrasound to simulate the phantom. Finally obtained plaques areas were analyzed through manual segmentation on simulation images. We could (1) directly evaluate the different beam-forming algorithms for the ultrasound imaging simulation on the effect of carotid artery; (2) also analyze the sensitivity of detection on different size of plaques; (3) indirectly reflect the accuracy of the manual segmentation base on segmentation results the evaluation.
NASA Astrophysics Data System (ADS)
Lyu, Bai-cheng; Wu, Wen-hua; Yao, Wei-an; Du, Yu
2017-06-01
Mooring system is the key equipment of FPSO safe operation. The soft yoke mooring system is regarded as one of the best shallow water mooring strategies and widely applied to the oil exploitation in the Bohai Bay in China and the Gulf of Mexico. Based on the analysis of numerous monitoring data obtained by the prototype monitoring system of one FPSO in the Bohai Bay, the on-site lateral vibration behaviors found on the site of the soft yoke subject to wave load were analyzed. ADAMS simulation and model experiment were utilized to analyze the soft yoke lateral vibration and it was determined that lateral vibration was resonance behaviors caused by wave excitation. On the basis of the soft yoke longitudinal restoring force being guaranteed, a TLD-based vibration damper system was constructed and the vibration reduction experiments with multi-tank space and multi-load conditions were developed. The experimental results demonstrated that the proposed TLD vibration reduction system can effectively reduce lateral vibration of soft yoke structures.
Pearce, Shane M; Pariser, Joseph J; Patel, Sanjay G; Anderson, Blake B; Eggener, Scott E; Zagaja, Gregory P
2016-02-01
To examine the effect of days off between cases on perioperative outcomes for robotic-assisted laparoscopic prostatectomy (RALP). We analyzed a single-surgeon series of 2036 RALP cases between 2003 and 2014. Days between cases (DBC) was calculated as the number of days elapsed since the surgeon's previous RALP with the second start cases assigned 0 DBC. Surgeon experience was assessed by dividing sequential case experience into cases 0-99, cases 100-249, cases 250-999, and cases 1000+ based on previously reported learning curve data for RALP. Outcomes included estimated blood loss (EBL), operative time (OT), and positive surgical margins (PSMs). Multiple linear regression was used to assess the impact of the DBC and surgeon experience on EBL, OT, and PSM, while controlling for patient characteristics, surgical technique, and pathologic variables. Overall median DBC was 1 day (0-3) and declined with increasing surgeon case experience. Multiple linear regression demonstrated that each additional DBC was independently associated with increased EBL [β = 3.7, 95% CI (1.3-6.2), p < 0.01] and OT [β = 2.3 (1.4-3.2), p < 0.01], but was not associated with rate of PSM [β = 0.004 (-0.003-0.010), p = 0.2]. Increased experience was also associated with reductions in EBL and OT (p < 0.01). Surgeon experience of 1000+ cases was associated with a 10% reduction in PSM rate (p = 0.03) compared to cases 0-99. In a large single-surgeon RALP series, DBC was associated with increased blood loss and operative time, but not associated with positive surgical margins, when controlling for surgeon experience.
Role of the vomeronasal system in intersexual attraction in female mice.
Martínez-Ricós, J; Agustín-Pavón, C; Lanuza, E; Martínez-García, F
2008-05-02
Although it is generally accepted that rodents' sociosexual behavior relies mainly on chemosignals, the specific roles played by the vomeronasal and olfactory systems in detecting these signals are presently unclear. This work reports the results of three experiments aimed at clarifying the role of the vomeronasal system on gender recognition and intersexual attraction, by analyzing the effects of lesions of the accessory olfactory bulbs (AOB) in chemically naïve female mice. The first experiment demonstrates that lesions of the AOB abolish the preference that females show for male-soiled bedding in tests in which the females can contact the bedding, thus having access to both volatile and involatile male chemosignals. The second experiment shows that airborne male-derived chemosignals are not attractive to intact, chemically naïve females but tend to be preferentially explored by females whose AOB has been lesioned. However, repeated exposure to male-soiled bedding has opposite effects in sham-operated and AOB-lesioned female mice. Whereas after this experience sham-operated females show an (acquired) attraction toward male airborne chemosignals, in AOB-lesioned females the same experience makes male-derived volatiles aversive. Finally, in the third experiment we have confirmed that our AOB-lesioned females are able to detect urine-borne male odorants, as well as to discriminate them from the synthetic terpene geraniol. These findings strongly suggest that in mice, the involatile male sexual pheromone that is intrinsically attractive is detected by the vomeronasal system of the females. In addition, the repeated experience of females with male-soiled bedding would probably allow the association of this pheromone, acting as unconditioned stimulus, with olfactory stimuli (odorants) that therefore would become conditioned attractors to the females.
The Sodium Exposure Test Cell to determine operating parameters for AMTEC electrochemical cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, M.A.; Williams, R.M.; Lara, L.
1998-07-01
The Sodium Exposure Test Cell (SETC) is a non-power producing cell which has been developed to evaluate and test components of the electrochemical cell in an Alkali Metal Thermal to Electric Converter. Performance and time dependence of performance of the electrode and the electrolyte in AMTEC cells can be tested in an SETC, and performance parameters which correlate with those taken from AMTEC operation can be calculated from data taken in an SETC. The components of the AMTEC electrochemical cell which are evaluated in an SETC are the electrode, {beta}{double{underscore}prime}-alumina solid electrolyte (BASE), the current collection network, and the containment.more » The components are held in low pressure sodium vapor at a temperature which reflects their operating conditions in an AMTEC device, and operating parameters determined. Electrodes and BASE are evaluated by measuring current-voltage (IV) characteristics and using Electrochemical Impedance Spectroscopy (EIS). Using these techniques, electrode performance parameters such as the exchange current (B), the morphology factor (G), and contact resistance between electrode and current collection network can be determined. The ionic conductivity (s) of BASE can also be determined. IV curves and EIS measurements are made at intervals over periods of several hundreds of hours in order to evaluate degradation of AMTEC electrochemical cell components. Electrode and BASE are analyzed after an SETC experiment using Scanning Electron Microscopy, Electron Dispersive Spectroscopy, and X-Ray Diffraction. These techniques allow evaluation of interaction of materials and changes in the composition and structure of materials. The purpose of these experiments is determination of the changes of operating parameters as a function of time in order to predict the operating lifetime of AMTEC cells.« less
Do we detect interplanetary dust with Faraday cups?
NASA Astrophysics Data System (ADS)
Kočiščák, S.; Pavlů, J.; Šafránková, J.; Němeček, Z.; Přech, L.
2018-07-01
Transient clouds of a plasma generated by hypervelocity dust particles impacting onto the spacecraft were observed in-situ by many experiments over the last 20 years. The reported observations analyze sensitive measurements of plasma waves that are transmitted to the Earth with a sufficient time resolution. The detection is based on a fact that hypervelocity impacts generate plumes of the ionized gas expanding into a space. The present paper analyzes five years of the operation of the Bright Monitor of the Solar Wind (BMSW) onboard the Spektr-R spacecraft with a motivation to demonstrate that such type of the instruments is capable to observe the dust impacts into its detectors. The results of analysis are compared with Wind electric field measurements used for a detection of hypervelocity dust impacts.
The use of piezosurgery in cranial surgery in children.
Ramieri, Valerio; Saponaro, Gianmarco; Lenzi, Jacopo; Caporlingua, Federico; Polimeni, Antonella; Silvestri, Alessandro; Pizzuti, Antonio; Roggini, Mario; Tarani, Luigi; Papoff, Paola; Giancotti, Antonella; Castori, Marco; Manganaro, Lucia; Cascone, Piero; Piero, Cascone
2015-05-01
Piezosurgery is an alternative surgical technique, now widely tested, that uses ultrasounds for bone cutting. This device uses ultrasounds to section hard tissues without harming surrounding soft tissues. The authors analyzed their experience in craniomaxillofacial procedures with piezosurgery. A comparison between operation timing and complication rates between piezosurgery and traditional cutting instruments has been performed. A total of 27 patients were examined (15 females and 12 males; average age, of 5.5 months) affected by craniosynostosis. The aim of this study was to analyze the advantages and disadvantages of piezosurgery in pediatric craniofacial procedures. Piezoelectric device in this study has shown being a valid instrument for bone cutting in accurate procedures, because it allows performing a more precise and safer cutting, without the risk of harming surrounding tissues.
OPERATIONAL EXPERIENCE WITH BEAM ABORT SYSTEM FOR SUPERCONDUCTING UNDULATOR QUENCH MITIGATION*
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harkay, Katherine C.; Dooling, Jeffrey C.; Sajaev, Vadim
A beam abort system has been implemented in the Advanced Photon Source storage ring. The abort system works in tandem with the existing machine protection system (MPS), and its purpose is to control the beam loss location and, thereby, minimize beam loss-induced quenches at the two superconducting undulators (SCUs). The abort system consists of a dedicated horizontal kicker designed to kick out all the bunches in a few turns after being triggered by MPS. The abort system concept was developed on the basis of single- and multi-particle tracking simulations using elegant and bench measurements of the kicker pulse. Performance ofmore » the abort system—kick amplitudes and loss distributions of all bunches—was analyzed using beam position monitor (BPM) turn histories, and agrees reasonably well with the model. Beam loss locations indicated by the BPMs are consistent with the fast fiber-optic beam loss monitor (BLM) diagnostics described elsewhere [1,2]. Operational experience with the abort system, various issues that were encountered, limitations of the system, and quench statistics are described.« less
NASA Astrophysics Data System (ADS)
Qiu, Yongfeng; Liu, Jinliang; Yang, Jianhua; Cheng, Xinbing; Yang, Xiao
2017-08-01
A compact control system based on Delphi and Field Programmable Gate Array(FPGA) is developed for a repetitive intense electron-beam accelerator(IEBA), whose output power is 10GW and pulse duration is 160ns. The system uses both hardware and software solutions. It comprises a host computer, a communication module and a main control unit. A device independent applications programming interface, devised using Delphi, is installed on the host computer. Stability theory of voltage in repetitive mode is analyzed and a detailed overview of the hardware and software configuration is presented. High voltage experiment showed that the control system fulfilled the requests of remote operation and data-acquisition. The control system based on a time-sequence control method is used to keep constant of the voltage of the primary capacitor in every shot, which ensured the stable and reliable operation of the electron beam accelerator in the repetitive mode during the experiment. Compared with the former control system based on Labview and PIC micro-controller developed in our laboratory, the present one is more compact, and with higher precision in the time dimension. It is particularly useful for automatic control of IEBA in the high power microwave effects research experiments where pulse-to-pulse reproducibility is required.
Carpenter, Christine
2011-01-01
ABSTRACT Purpose: Military physiotherapists in the Canadian Forces meet the unique rehabilitation needs of military personnel. Recently, the physiotherapy officer role has evolved in response to the Canadian Forces' involvement in the combat theatre of operations of Afghanistan, and this has created new and unique challenges and demands. The purpose of this study was to describe the experiences and challenges of military physiotherapists deployed to Afghanistan. Methods: A qualitative research design guided by descriptive phenomenology involved recruitment of key informants and in-depth interviews as the data collection method. The interviews were transcribed verbatim and the data analyzed using a foundational thematic analysis approach. Strategies of peer review and member checking were incorporated into the study design. Results: Six military physiotherapists were interviewed. They described rewarding experiences that were stressful yet highly career-satisfying. Main challenges revolved around heavy workloads, an expanded scope of practice as sole-charge practitioners, and the consequences and criticality of their clinical decisions. Conclusions: Our findings suggest that enhanced pre-deployment training and the implementation of a stronger support network will improve the capabilities of military physiotherapists deployed to difficult theatres of operations. This type of systematic and comprehensive research is needed to assist the Canadian Forces in proactively preparing and supporting physiotherapists deployed on future missions. PMID:22942524
Chechetkin, A V; Popova, N N; Kuz'min, N S; Fedotov, Iu P
2004-01-01
The authors analyze the experience of organization of the wounded and patient provision with hemotransfusion materials to render assistance during antiterrorist operation in Republic of Dagestan and Republic of Chechnya in 1999-2001. It is shown that supply of military treatment-and-prophylactic institutions deployed in the zone of military conflict, of specialized hospitals with hemotransfusion materials was the following: with blood preparations (at the expense of centralized deliveries), with blood components (91.8%, at the expense of centralized deliveries form the district blood transfusion station). The volume of stored blood taken from emergency reserve donors in the military treatment-and-prophylactic institutions located near the zone of military actions constituted 8.2% of the total volume of blood components received.
Mechatronic description of a laser autoguided vehicle for greenhouse operations.
Sánchez-Hermosilla, Julián; González, Ramón; Rodríguez, Francisco; Donaire, Julián G
2013-01-08
This paper presents a novel approach for guiding mobile robots inside greenhouses demonstrated by promising preliminary physical experiments. It represents a comprehensive attempt to use the successful principles of AGVs (auto-guided vehicles) inside greenhouses, but avoiding the necessity of modifying the crop layout, and avoiding having to bury metallic pipes in the greenhouse floor. The designed vehicle can operate different tools, e.g., a spray system for applying plant-protection product, a lifting platform to reach the top part of the plants to perform pruning and harvesting tasks, and a trailer to transport fruits, plants, and crop waste. Regarding autonomous navigation, it follows the idea of AGVs, but now laser emitters are used to mark the desired route. The vehicle development is analyzed from a mechatronic standpoint (mechanics, electronics, and autonomous control).
Witnessing entanglement without entanglement witness operators.
Pezzè, Luca; Li, Yan; Li, Weidong; Smerzi, Augusto
2016-10-11
Quantum mechanics predicts the existence of correlations between composite systems that, although puzzling to our physical intuition, enable technologies not accessible in a classical world. Notwithstanding, there is still no efficient general method to theoretically quantify and experimentally detect entanglement of many qubits. Here we propose to detect entanglement by measuring the statistical response of a quantum system to an arbitrary nonlocal parametric evolution. We witness entanglement without relying on the tomographic reconstruction of the quantum state, or the realization of witness operators. The protocol requires two collective settings for any number of parties and is robust against noise and decoherence occurring after the implementation of the parametric transformation. To illustrate its user friendliness we demonstrate multipartite entanglement in different experiments with ions and photons by analyzing published data on fidelity visibilities and variances of collective observables.
Development of Next Generation Memory Test Experiment for Deployment on a Small Satellite
NASA Technical Reports Server (NTRS)
MacLeod, Todd; Ho, Fat D.
2012-01-01
The original Memory Test Experiment successfully flew on the FASTSAT satellite launched in November 2010. It contained a single Ramtron 512K ferroelectric memory. The memory device went through many thousands of read/write cycles and recorded any errors that were encountered. The original mission length was schedule to last 6 months but was extended to 18 months. New opportunities exist to launch a similar satellite and considerations for a new memory test experiment should be examined. The original experiment had to be designed and integrated in less than two months, so the experiment was a simple design using readily available parts. The follow-on experiment needs to be more sophisticated and encompass more technologies. This paper lays out the considerations for the design and development of this follow-on flight memory experiment. It also details the results from the original Memory Test Experiment that flew on board FASTSAT. Some of the design considerations for the new experiment include the number and type of memory devices to be used, the kinds of tests that will be performed, other data needed to analyze the results, and best use of limited resources on a small satellite. The memory technologies that are considered are FRAM, FLASH, SONOS, Resistive Memory, Phase Change Memory, Nano-wire Memory, Magneto-resistive Memory, Standard DRAM, and Standard SRAM. The kinds of tests that could be performed are read/write operations, non-volatile memory retention, write cycle endurance, power measurements, and testing Error Detection and Correction schemes. Other data that may help analyze the results are GPS location of recorded errors, time stamp of all data recorded, radiation measurements, temperature, and other activities being perform by the satellite. The resources of power, volume, mass, temperature, processing power, and telemetry bandwidth are extremely limited on a small satellite. Design considerations must be made to allow the experiment to not interfere with the satellite s primary mission.
Ortenzi, Monica; Ghiselli, Roberto; Baldarelli, Maddalena; Cardinali, Luca; Guerrieri, Mario
2018-04-01
The latest robotic bipolar vessel sealing tools have been described to be effective allowing to perform procedures with reduced blood loss and shorter operative times. The aim of this study was to assess the efficacy and reliability of these devices applied in different robotic procedures. All robotic operations, between 2014 and 2016, were performed using the EndoWrist One VesselSealer (EWO, Intuitive Surgical, Sunnyvale, CA), a bipolar fully wristed device. Data, including age, gender, body mass index (BMI), were collected. Robot docking time, intraoperative blood loss, robot malfunctioning and overall operative time were analyzed. A meta-analysis of the literature was carried out to point the attention to three different parameters (mean blood loss, operating time and hospital stay) trying to identify how different coagulation devices may affect them. In 73 robotic procedures, the mean operative time was 118.2 minutes (75-125 minutes). Mean hospital stay was four days (2-10 days). There were two post-operative complications (2.74%). The bipolar vessel sealer offers the efficacy of bipolar diathermy and the advantages of a fully wristed instrument. It does not require any change of instruments for coagulation or involvement of the bedside assistant surgeon. These characteristics lead to a reduction in operative time.
NASA Technical Reports Server (NTRS)
Khovanskiy, Y. D.; Kremneva, N. I.
1975-01-01
Problems and methods are discussed of automating information retrieval operations in a data bank used for long term storage and retrieval of data from scientific experiments. Existing information retrieval languages are analyzed along with those being developed. The results of studies discussing the application of the descriptive 'Kristall' language used in the 'ASIOR' automated information retrieval system are presented. The development and use of a specialized language of the classification-descriptive type, using universal decimal classification indices as the main descriptors, is described.
Design and performance of an astigmatism-compensated self-mode-locked ring-cavity Ti:sapphire laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Y.; Dai, J.; Wang, Q.
1996-12-31
Based on the nonlinear ABCD matrix and the renormalized q-parameter for Gaussian-beam propagation, self-focusing in conjunction with a spatial gain profile for self-mode locking in a ring-cavity Ti:sapphire laser is analyzed. In the experiment, an astigmatism-compensated self-mode-locked ring-cavity Ti:sapphire laser is demonstrated, and self-mode-locked operation is achieved in both bidirection and unidirection with pulse durations as short as 36 fs and 32 fs, respectively. The experimental observations are in good agreement with theoretical predictions.
Janakiraman, Eswari Natt; Alexander, Mohan; Sanjay, Pasupathy
2010-05-01
The objective of this prospective study was to determine the incidence of injury to the inferior alveolar and lingual nerves following surgical removal of impacted mandibular third molars and to evaluate the various factors contributing to the same. A total of 119 patients underwent mandibular third-molar removal during the period of 11 months. Of 119, 3 inferior alveolar nerve and 5 lingual nerve injuries were encountered. Various factors such as lingual retraction, surgical time, operator experience, radiologic findings contributing to the injury were correlated and analyzed.
2017-06-09
analysis method and focus on analyzing available documents while studying the separate but similar cases of Israel fighting Hezbollah in Lebanon and...two significant case studies will be reviewed. One deals with the conflict between Hezbollah and Israel Defense Forces (IDF) in Israel and Lebanon...Vietnam and in Operation Iraqi Freedom. Captain Houvinen in his research presented a case study from the Second Lebanon War based on the U.S. experience
High-speed optical three-axis vector magnetometry based on nonlinear Hanle effect in rubidium vapor
NASA Astrophysics Data System (ADS)
Azizbekyan, Hrayr; Shmavonyan, Svetlana; Khanbekyan, Aleksandr; Movsisyan, Marina; Papoyan, Aram
2017-07-01
The magnetic-field-compensation optical vector magnetometer based on the nonlinear Hanle effect in alkali metal vapor allowing two-axis measurement operation has been further elaborated for three-axis performance, along with significant reduction of measurement time. The upgrade was achieved by implementing a two-beam resonant excitation configuration and a fast maximum searching algorithm. Results of the proof-of-concept experiments, demonstrating 1 μT B-field resolution, are presented. The applied interest and capability of the proposed technique is analyzed.
Solovjev, V A
1987-09-01
Today, more than 20 years after the first in the world man's space walk, soviet cosmonautics gained large experience of extravehicular activity (EVA). Space suits of high reliability, onboard facilities for passing through the airlock, sets of special tools and technological rigging, as well as procedures for carrying out various EVA's were developed. In the course of the Salyut-7 space station orbital operation the EVA's have become regular. The author of the report as the participant of the EVA's considers the main steps of man activities in space and analyzes specific problems arised in performing such activities.
All-fiber highly chirped dissipative soliton generation in the telecom range.
Kharenko, Denis S; Zhdanov, Innokentiy S; Bednyakova, Anastasia E; Podivilov, Evgeniy V; Fedoruk, Mikhail P; Apolonski, Alexander; Turitsyn, Sergei K; Babin, Sergey A
2017-08-15
A high-energy (0.93 nJ) all-fiber erbium femtosecond oscillator operating in the telecom spectral range is proposed and realized. The laser cavity, built of commercially available fibers and components, combines polarization maintaining (PM) and non-PM parts providing stable generation of highly chirped (chirp parameter 40) pulses compressed in an output piece of standard PM fiber to 165 fs. The results of the numerical simulation agree well with the experiment. The analyzed intracavity pulse dynamics enables the classification of the generated pulses as dissipative solitons.
Y-MP floating point and Cholesky factorization
NASA Technical Reports Server (NTRS)
Carter, Russell
1991-01-01
The floating point arithmetics implemented in the Cray 2 and Cray Y-MP computer systems are nearly identical, but large scale computations performed on the two systems have exhibited significant differences in accuracy. The difference in accuracy is analyzed for Cholesky factorization algorithm, and it is found that the source of the difference is the subtract magnitude operation of the Cray Y-MP. The results from numerical experiments for a range of problem sizes are presented, and an efficient method for improving the accuracy of the factorization obtained on the Y-MP is presented.
Developing a Theory-Based Simulation Educator Resource.
Thomas, Christine M; Sievers, Lisa D; Kellgren, Molly; Manning, Sara J; Rojas, Deborah E; Gamblian, Vivian C
2015-01-01
The NLN Leadership Development Program for Simulation Educators 2014 faculty development group identified a lack of a common language/terminology to outline the progression of expertise of simulation educators. The group analyzed Benner's novice-to-expert model and applied its levels of experience to simulation educator growth. It established common operational categories of faculty development and used them to organize resources that support progression toward expertise. The resulting theory-based Simulator Educator Toolkit outlines levels of ability and provides quality resources to meet the diverse needs of simulation educators and team members.
1988-07-01
depend on the duration of the pulse . The earlier results are nov extended to laser intensities of the order of 1012-10 13W/cm 2. The description of...projection operator formalism, described in (1) to analyze a state of a hydrogen atom in a very intense laser field. A starting Hamiltonian in dipole...system. The results of the microwave experiments are expected to scale to the case of excited multiply-charged hydrogenic ions in intense short- pulse
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goudarzi, S., E-mail: sgoudarzi@aeoi.org.ir; Babaee, H.; Esmaeli, A.
SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D{sub 2} working gases at several discharge voltages and initial pressures are presented and analyzed.
NASA Astrophysics Data System (ADS)
Goudarzi, S.; Babaee, H.; Esmaeli, A.; Nasiri, A.
2017-01-01
SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D2 working gases at several discharge voltages and initial pressures are presented and analyzed.
STS-107 Microgravity Environment Summary Report
NASA Technical Reports Server (NTRS)
Jules, Kenol; Hrovat, Kenneth; Kelly, Eric; Reckhart, Timothy
2005-01-01
This summary report presents the results of the processed acceleration data measured aboard the Columbia orbiter during the STS-107 microgravity mission from January 16 to February 1, 2003. Two accelerometer systems were used to measure the acceleration levels due to vehicle and science operations activities that took place during the 16-day mission. Due to lack of precise timeline information regarding some payload's operations, not all of the activities were analyzed for this report. However, a general characterization of the microgravity environment of the Columbia Space Shuttle during the 16-day mission is presented followed by a more specific characterization of the environment for some designated payloads during their operations. Some specific quasi-steady and vibratory microgravity environment characterization analyses were performed for the following payloads: Structure of Flame Balls at Low Lewis-number-2, Laminar Soot Processes-2, Mechanics of Granular Materials-3 and Water Mist Fire-Suppression Experiment. The Physical Science Division of the National Aeronautics and Space Administration sponsors the Orbital Acceleration Research Experiment and the Space Acceleration Measurement System for Free Flyer to support microgravity science experiments, which require microgravity acceleration measurements. On January 16, 2003, both the Orbital Acceleration Research Experiment and the Space Acceleration Measurement System for Free Flyer accelerometer systems were launched on the Columbia Space Transportation System-107 from the Kennedy Space Center. The Orbital Acceleration Research Experiment supported science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System for Free Flyer unit supported experiments requiring vibratory acceleration measurement. The Columbia reduced gravity environment analysis presented in this report uses acceleration data collected by these two sets of accelerometer systems: The Orbital Acceleration Research Experiment is a low frequency sensor, which measures acceleration up to 1 Hz, but the 1 Hz acceleration data is trimmean filtered to yield much lower frequency acceleration data up to 0.01 Hz. This filtered data can be mapped to other locations for characterizing the quasi-steady environment for payloads and the vehicle. The Space Acceleration Measurement System for Free Flyer measures vibratory acceleration in the range of 0.01 to 200 Hz at multiple measurement locations. The vibratory acceleration data measured by this system is used to assess the local vibratory environment for payloads as well as to measure the disturbance causes by the vehicle systems, crew exercise devices and payloads operation disturbances. This summary report presents analysis of selected quasi-steady and vibratory activities measured by these two accelerometers during the Columbia 16-day microgravity mission from January 16 to February 1, 2003.
Surgical treatment of chronic pancreatitis--a 14 years experience.
Stroescu, C; Dima, S; Scarlat, A; Ivanov, B; Bouaru, O; Ionescu, M; Vasilescu, C; Popescu, I
2010-01-01
Operative treatment of chronic pancreatitis is indicated for patients with intractable pain after failed medical and endoscopic treatment, or in the presence of complications of the disease. This study evaluates a single-center experience with operative management of chronic pancreatitis over a period of time of 14 years, regarding indication, surgical technique, early and late results. The records of 265 consecutive patients who underwent surgery for chronic pancreatitis between 1995 and 2008 were retrospectively reviewed and analyzed. Long-term outcomes were assessed by patient survey, with a median follow-up of 40 months. 265 patients underwent 275 operations for chronic pancreatitis with the main indication abdominal pain (46.8%), followed by suspected malignancy in 24.8% and recurrent episodes of acute pancreatitis in 18.6%. Resection procedures 54.5% (150), drainage procedures 1.09% (3), bypass and denervation procedures 44.36% (122) and exploratory laparotomy 3.27% (9) were performed with an overall morbidity of 22% and an in-hospital mortality rate of 2.64%. After a median follow-up of 40 months survival information was available for 137 patients (51.69%) with a 5-and actuarial survival rate of 74.7% and quality of life improvement in most patients, especially in the resected group. Our results suggest that in chronic pancreatitis the type of surgery has to be individualized in each patient (resection VS drainage) and organ preserving operations are safe and effective in providing long-term pain relief and in treating CP-related complications
Live animals for preclinical medical student surgical training
DeMasi, Stephanie C.; Katsuta, Eriko; Takabe, Kazuake
2016-01-01
Aims The use of live animals for surgical training is a well-known, deliberated topic. However, medical students who use live animals rate the experience high not only in improving their surgical techniques, but also positively influencing their confidence levels in the operating room later in their careers. Therefore, we hypothesized that the use of live animal models is a unique and influential component of preclinical medical education. Materials and Methods Medical student performed the following surgical procedures using mice; surgical orthotopic implantation of cancer cells into fat pad and subsequently a radical mastectomy. The improvement of skill was then analyzed. Results All cancer cell inoculations were performed successfully. Improvement of surgical skills during the radical mastectomy procedure was documented in all parameters. All wounds healed without breakdown or dehiscence. The appropriate interval between interrupted sutures was ascertained after fifth wound closure. The speed of interrupted sutures was doubled by last wound closure. The time required to complete a radical mastectomy decreased by almost half. A single animal died immediately following the operation due to inappropriate anesthesia, which was attributed to the lack of understanding of the overall operative management. Conclusion Surgical training using live animals for preclinical medical students provides a unique learning experience, not only in improving surgical skills but also and arguably most importantly, to introduce the student to the complexities of the perioperative environment in a way that most closely resembles the stress and responsibility that the operating room demands. PMID:28713875
Determination of the Proper Rest Time for a Cyclic Mental Task Using ACT-R Architecture.
Atashfeshan, Nooshin; Razavi, Hamideh
2017-03-01
Objective Analysis of the effect of mental fatigue on a cognitive task and determination of the right start time for rest breaks in work environments. Background Mental fatigue has been recognized as one of the most important factors influencing individual performance. Subjective and physiological measures are popular methods for analyzing fatigue, but they are restricted to physical experiments. Computational cognitive models are useful for predicting operator performance and can be used for analyzing fatigue in the design phase, particularly in industrial operations and inspections where cognitive tasks are frequent and the effects of mental fatigue are crucial. Method A cyclic mental task is modeled by the ACT-R architecture, and the effect of mental fatigue on response time and error rate is studied. The task includes visual inspections in a production line or control workstation where an operator has to check products' conformity to specifications. Initially, simulated and experimental results are compared using correlation coefficients and paired t test statistics. After validation of the model, the effects are studied by human and simulated results, which are obtained by running 50-minute tests. Results It is revealed that during the last 20 minutes of the tests, the response time increased by 20%, and during the last 12.5 minutes, the error rate increased by 7% on average. Conclusion The proper start time for the rest period can be identified by setting a limit on the error rate or response time. Application The proposed model can be applied early in production planning to decrease the negative effects of mental fatigue by predicting the operator performance. It can also be used for determining the rest breaks in the design phase without an operator in the loop.
López Saiz, A; Vila Carbó, J J; Fernández, M S; Muro, D; Ibáñez, V; Gutiérrez, C; Roca, A; García-Sala, C
1997-07-01
A retrospective and transversal study of our patients with portal cavernomatosis is developed, with the aim of comparing the evolution and the present status of the patients that have undergone different therapeutical approaches. Between 1975 and 1995, 15 patients with portal cavernomatosis have been treated. Personal history, signs and symptoms at the moment of diagnosis, and treatment were analyzed. Now, the controls have been made by physical examination and ECO-Doppler of the espleno-portal system. In 6 cases the absence of bleeding made surgery unnecessary. In the 9 patients with digestive haemorrhage, it could be controlled pharmacologically, with a later surgical approach. Now, all non-operated and 6 operated patients show splenomegaly, without bleeding. The ECO-Doppler shows colateral flow, the splenomegaly in the non-operated and the surgical shunts and the hepatofugal circulation in the operated patients. Looking at our results, we believe that prophylactic surgery is not indicated. In those cases of digestive bleeding, surgery after the complete resolution of the acute disease shows good results at a short and long term.
Zhu, Mingwen; Zhang, Zongming; Lin, Fangcai; Miao, Jieping; Wang, Pei; Zhang, Chong; Yu, Hongwei; Deng, Hai; Liu, Zhuo; Liu, Limin; Wan, Baijiang; Yang, Haiyan; Song, Mengmeng; Zhao, Yue; Jiang, Nan; Zhang, Zichao; Zhang, Zhenya; Pan, Lijie
2018-05-01
For patients with refractory secondary hyperparathyroidism (SHPT), parathyroidectomy (PTX) has received increasing attention. However, evidence-based medicine shows that there is still controversy regarding surgical methods, efficacy, and safety. We retrospectively analyzed the process of diagnosis and treatment in one patient with severe SHPT and long-term chronic renal failure (CRF), so as to further improve the therapeutic effect. A 61-year-old female with SHPT and CRF manifested as no urine for 18 years, underwent PTX 4 times since September 2010, with satisfactory final recovery. The first operation involved resection of 3 parathyroid glands in the normal position; the second operation involved removal of an ectopic parathyroid gland, combined with parathyroid gland autotransplantation; the third operation was performed to resect suspected recurrent parathyroid gland; the fourth operation involved partial excision of the autotransplanted parathyroid glands. Accurate preoperative localized diagnosis and optimal surgical approach play key roles in the prevention and treatment of SHPT; postoperative recurrence of SHPT caused by ectopic or autotransplanted parathyroid gland should receive more attention.
IoT-based smart garbage system for efficient food waste management.
Hong, Insung; Park, Sunghoi; Lee, Beomseok; Lee, Jaekeun; Jeong, Daebeom; Park, Sehyun
2014-01-01
Owing to a paradigm shift toward Internet of Things (IoT), researches into IoT services have been conducted in a wide range of fields. As a major application field of IoT, waste management has become one such issue. The absence of efficient waste management has caused serious environmental problems and cost issues. Therefore, in this paper, an IoT-based smart garbage system (SGS) is proposed to reduce the amount of food waste. In an SGS, battery-based smart garbage bins (SGBs) exchange information with each other using wireless mesh networks, and a router and server collect and analyze the information for service provisioning. Furthermore, the SGS includes various IoT techniques considering user convenience and increases the battery lifetime through two types of energy-efficient operations of the SGBs: stand-alone operation and cooperation-based operation. The proposed SGS had been operated as a pilot project in Gangnam district, Seoul, Republic of Korea, for a one-year period. The experiment showed that the average amount of food waste could be reduced by 33%.
IoT-Based Smart Garbage System for Efficient Food Waste Management
Lee, Jaekeun
2014-01-01
Owing to a paradigm shift toward Internet of Things (IoT), researches into IoT services have been conducted in a wide range of fields. As a major application field of IoT, waste management has become one such issue. The absence of efficient waste management has caused serious environmental problems and cost issues. Therefore, in this paper, an IoT-based smart garbage system (SGS) is proposed to reduce the amount of food waste. In an SGS, battery-based smart garbage bins (SGBs) exchange information with each other using wireless mesh networks, and a router and server collect and analyze the information for service provisioning. Furthermore, the SGS includes various IoT techniques considering user convenience and increases the battery lifetime through two types of energy-efficient operations of the SGBs: stand-alone operation and cooperation-based operation. The proposed SGS had been operated as a pilot project in Gangnam district, Seoul, Republic of Korea, for a one-year period. The experiment showed that the average amount of food waste could be reduced by 33%. PMID:25258730
Combustor Operability and Performance Verification for HIFiRE Flight 2
NASA Technical Reports Server (NTRS)
Storch, Andrea M.; Bynum, Michael; Liu, Jiwen; Gruber, Mark
2011-01-01
As part of the Hypersonic International Flight Research Experimentation (HIFiRE) Direct-Connect Rig (HDCR) test and analysis activity, three-dimensional computational fluid dynamics (CFD) simulations were performed using two Reynolds-Averaged Navier Stokes solvers. Measurements obtained from ground testing in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF) were used to specify inflow conditions for the simulations and combustor data from four representative tests were used as benchmarks. Test cases at simulated flight enthalpies of Mach 5.84, 6.5, 7.5, and 8.0 were analyzed. Modeling parameters (e.g., turbulent Schmidt number and compressibility treatment) were tuned such that the CFD results closely matched the experimental results. The tuned modeling parameters were used to establish a standard practice in HIFiRE combustor analysis. Combustor performance and operating mode were examined and were found to meet or exceed the objectives of the HIFiRE Flight 2 experiment. In addition, the calibrated CFD tools were then applied to make predictions of combustor operation and performance for the flight configuration and to aid in understanding the impacts of ground and flight uncertainties on combustor operation.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
...-05: Ongoing Review of Operating Experience AGENCY: Nuclear Regulatory Commission. ACTION: Interim... License Renewal Interim Staff Guidance (LR-ISG), LR-ISG-2011-05, ``Ongoing Review of Operating Experience... industry-wide operating experience as an attribute of aging management programs used at nuclear power...
TRACE/PARCS Analysis of ATWS with Instability for a MELLLA+BWR/5
L. Y. Cheng; Baek, J. S.; Cuadra, A.; ...
2016-06-06
A TRACE/PARCS model has been developed to analyze anticipated transient without SCRAM (ATWS) events for a boiling water reactor (BWR) operating in the maximum extended load line limit analysis-plus (MELLLA+) expanded operating domain. The MELLLA+ domain expands allowable operation in the power/flow map of a BWR to low flow rates at high power conditions. Such operation exacerbates the likelihood of large amplitude power/flow oscillations during certain ATWS scenarios. The analysis shows that large amplitude power/flow oscillations, both core-wide and out-of-phase, arise following the establishment of natural circulation flow in the reactor pressure vessel (RPV) after the trip of the recirculationmore » pumps and an increase in core inlet subcooling. The analysis also indicates a mechanism by which the fuel may experience heat-up that could result in localized fuel damage. TRACE predicts the heat-up to occur when the cladding surface temperature exceeds the minimum stable film boiling temperature after periodic cycles of dryout and rewet; and the fuel becomes “locked” into a film boiling regime. Further, the analysis demonstrates the effectiveness of the simulated manual operator actions to suppress the instability.« less
Web-based multi-channel analyzer
Gritzo, Russ E.
2003-12-23
The present invention provides an improved multi-channel analyzer designed to conveniently gather, process, and distribute spectrographic pulse data. The multi-channel analyzer may operate on a computer system having memory, a processor, and the capability to connect to a network and to receive digitized spectrographic pulses. The multi-channel analyzer may have a software module integrated with a general-purpose operating system that may receive digitized spectrographic pulses for at least 10,000 pulses per second. The multi-channel analyzer may further have a user-level software module that may receive user-specified controls dictating the operation of the multi-channel analyzer, making the multi-channel analyzer customizable by the end-user. The user-level software may further categorize and conveniently distribute spectrographic pulse data employing non-proprietary, standard communication protocols and formats.
Baseline Architecture of ITER Control System
NASA Astrophysics Data System (ADS)
Wallander, A.; Di Maio, F.; Journeaux, J.-Y.; Klotz, W.-D.; Makijarvi, P.; Yonekawa, I.
2011-08-01
The control system of ITER consists of thousands of computers processing hundreds of thousands of signals. The control system, being the primary tool for operating the machine, shall integrate, control and coordinate all these computers and signals and allow a limited number of staff to operate the machine from a central location with minimum human intervention. The primary functions of the ITER control system are plant control, supervision and coordination, both during experimental pulses and 24/7 continuous operation. The former can be split in three phases; preparation of the experiment by defining all parameters; executing the experiment including distributed feed-back control and finally collecting, archiving, analyzing and presenting all data produced by the experiment. We define the control system as a set of hardware and software components with well defined characteristics. The architecture addresses the organization of these components and their relationship to each other. We distinguish between physical and functional architecture, where the former defines the physical connections and the latter the data flow between components. In this paper, we identify the ITER control system based on the plant breakdown structure. Then, the control system is partitioned into a workable set of bounded subsystems. This partition considers at the same time the completeness and the integration of the subsystems. The components making up subsystems are identified and defined, a naming convention is introduced and the physical networks defined. Special attention is given to timing and real-time communication for distributed control. Finally we discuss baseline technologies for implementing the proposed architecture based on analysis, market surveys, prototyping and benchmarking carried out during the last year.
Analyzing multimodality tomographic images and associated regions of interest with MIDAS
NASA Astrophysics Data System (ADS)
Tsui, Wai-Hon; Rusinek, Henry; Van Gelder, Peter; Lebedev, Sergey
2001-07-01
This paper outlines the design and features incorporated in a software package for analyzing multi-modality tomographic images. The package MIDAS has been evolving for the past 15 years and is in wide use by researchers at New York University School of Medicine and a number of collaborating research sites. It was written in the C language and runs on Sun workstations and Intel PCs under the Solaris operating system. A unique strength of the MIDAS package lies in its ability to generate, manipulate and analyze a practically unlimited number of regions of interest (ROIs). These regions are automatically saved in an efficient data structure and linked to associated images. A wide selection of set theoretical (e.g. union, xor, difference), geometrical (e.g. move, rotate) and morphological (grow, peel) operators can be applied to an arbitrary selection of ROIs. ROIs are constructed as a result of image segmentation algorithms incorporated in MIDAS; they also can be drawn interactively. These ROI editing operations can be applied in either 2D or 3D mode. ROI statistics generated by MIDAS include means, standard deviations, centroids and histograms. Other image manipulation tools incorporated in MIDAS are multimodality and within modality coregistration methods (including landmark matching, surface fitting and Woods' correlation methods) and image reformatting methods (using nearest-neighbor, tri-linear or sinc interpolation). Applications of MIDAS include: (1) neuroanatomy research: marking anatomical structures in one orientation, reformatting marks to another orientation; (2) tissue volume measurements: brain structures (PET, MRI, CT), lung nodules (low dose CT), breast density (MRI); (3) analysis of functional (SPECT, PET) experiments by overlaying corresponding structural scans; (4) longitudinal studies: regional measurement of atrophy.
Data acquisition and processing system for the HT-6M tokamak fusion experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shu, Y.T.; Liu, G.C.; Pang, J.Q.
1987-08-01
This paper describes a high-speed data acquisition and processing system which has been successfully operated on the HT-6M tokamak fusion experimental device. The system collects, archives and analyzes up to 512 kilobytes of data from each shot of the experiment. A shot lasts 50-150 milliseconds and occurs every 5-10 minutes. The system consists of two PDP-11/24 computer systems. One PDP-11/24 is used for real-time data taking and on-line data analysis. It is based upon five CAMAC crates organized into a parallel branch. Another PDP-11/24 is used for off-line data processing. Both data acquisition software RSX-DAS and data processing software RSX-DAPmore » have modular, multi-tasking and concurrent processing features.« less
An algorithm for monitoring the traffic on a less-travelled road using multi-modal sensor suite
NASA Astrophysics Data System (ADS)
Damarla, Thyagaraju; Chatters, Gary; Liss, Brian; Vu, Hao; Sabatier, James M.
2014-06-01
We conducted an experiment to correlate the information gathered by a suite of hard sensors with the information on social networks such as Twitter, Facebook, etc. The experiment consisting of monitoring traffic on a well- traveled road and on a road inside a facility. The sensors suite selected mainly consists of sensors that require low power for operation and last a longtime. The output of each sensor is analyzed to classify the targets as ground vehicles, humans, and airborne targets. The algorithm is also used to count the number of targets belonging to each type so the sensor can store the information for anomaly detection. In this paper, we describe the classifier algorithms used for acoustic, seismic, and passive infrared (PIR) sensor data.
Cell Radiation Experiment System
NASA Technical Reports Server (NTRS)
Morrison, Dennis R.
2010-01-01
The cell radiation experiment system (CRES) is a perfused-cell culture apparatus, within which cells from humans or other animals can (1) be maintained in homeostasis while (2) being exposed to ionizing radiation during controlled intervals and (3) being monitored to determine the effects of radiation and the repair of radiation damage. The CRES can be used, for example, to determine effects of drug, radiation, and combined drug and radiation treatments on both normal and tumor cells. The CRES can also be used to analyze the effects of radiosensitive or radioprotectant drugs on cells subjected to radiation. The knowledge gained by use of the CRES is expected to contribute to the development of better cancer treatments and of better protection for astronauts, medical-equipment operators, and nuclear-power-plant workers, and others exposed frequently to ionizing radiation.
NASA Technical Reports Server (NTRS)
Coho, William K.; Weiland, Karen J.; VanZandt, David M.
1998-01-01
A space experiment designed to study the behavior of combustion without the gravitational effects of buoyancy was launched aboard the Space Shuttle Columbia on July 1, 1997. The space experiment, designated as Combustion Module-1 (CM-1), was one of several manifested on the Microgravity Sciences Laboratory - 1 (MSL-1) mission. The launch, designated STS-94, had the Spacelab Module as the payload, in which the MSL-1 experiments were conducted by the Shuttle crewmembers. CM-1 was designed to accommodate two different combustion experiments during MSL-1. One experiment, the Structure of Flame Balls at Low Lewis-number experiment (SOFBALL), required gas chromatography analysis to verify the composition of the known, premixed gases prior to combustion, and to determine the remaining reactant and the products resulting from the combustion process in microgravity. A commercial, off-the-shelf, dual-channel micro gas chromatograph was procured and modified to interface with the CM-1 Fluids Supply Package and the CM-1 Combustion Chamber, to accommodate two different carrier gases, each flowing through its own independent column module, to withstand the launch environment of the Space Shuttle, to accept Spacelab electrical power, and to meet the Spacelab flight requirements for electromagnetic interference (EMI) and offgassing. The GC data was down linked to the Marshall Space Flight Center for near-real time analysis, and stored on-orbit for post-flight analysis. The gas chromatograph operated successfully during the entire SOFBALL experiment and collected 309 runs. Because of the constraints imposed upon the gas chromatograph by the CM-1 hardware, system and operations, it was unable to measure the gases to the required accuracy. Future improvements to the system for a re-flight of the SOFBALL experiment are expected to enable the gas chromatograph to meet all the requirements.
Adaptive servo control for umbilical mating
NASA Technical Reports Server (NTRS)
Zia, Omar
1988-01-01
Robotic applications at Kennedy Space Center are unique and in many cases require the fime positioning of heavy loads in dynamic environments. Performing such operations is beyond the capabilities of an off-the-shelf industrial robot. Therefore Robotics Applications Development Laboratory at Kennedy Space Center has put together an integrated system that coordinates state of the art robotic system providing an excellent easy to use testbed for NASA sensor integration experiments. This paper reviews the ways of improving the dynamic response of the robot operating under force feedback with varying dynamic internal perturbations in order to provide continuous stable operations under variable load conditions. The goal is to improve the stability of the system with force feedback using the adaptive control feature of existing system over a wide range of random motions. The effect of load variations on the dynamics and the transfer function (order or values of the parameters) of the system has been investigated, more accurate models of the system have been determined and analyzed.
The ATLAS PanDA Pilot in Operation
NASA Astrophysics Data System (ADS)
Nilsson, P.; Caballero, J.; De, K.; Maeno, T.; Stradling, A.; Wenaus, T.; ATLAS Collaboration
2011-12-01
The Production and Distributed Analysis system (PanDA) [1-2] was designed to meet ATLAS [3] requirements for a data-driven workload management system capable of operating at LHC data processing scale. Submitted jobs are executed on worker nodes by pilot jobs sent to the grid sites by pilot factories. This paper provides an overview of the PanDA pilot [4] system and presents major features added in light of recent operational experience, including multi-job processing, advanced job recovery for jobs with output storage failures, gLExec [5-6] based identity switching from the generic pilot to the actual user, and other security measures. The PanDA system serves all ATLAS distributed processing and is the primary system for distributed analysis; it is currently used at over 100 sites worldwide. We analyze the performance of the pilot system in processing real LHC data on the OSG [7], EGI [8] and Nordugrid [9-10] infrastructures used by ATLAS, and describe plans for its evolution.
[Thoracoscopic thymectomy in children by myasthenia gravis].
Razumovskiĭ, A Iu; Alkhasov, A B; Mitupov, Z B; Sanadze, A G; Sidnev, D V; Dallakian, D N; Smirnova, S V
2013-01-01
The authors' experience of surgical treatment of myasthenia gravis in children was analyzed. 32 patients were operated on, mean age was 13±3 (5-21 years); girls were 26, boys were 6 (19%). Disease severity was IIB-IVB by the MGFA classification, all patients were on anticholinesterase and pednisolone therapy. The operation was indicated by certified neurologists, specialized in myasthenia. All patient were thoracoscopically thymectomized using left- or rightside access. There were no conversions and intraoperative complications. The operation duration was 77±23 min. The postoperative hospital stay was 6.6±3.6 (3-9) days. Excellent long-term results were achieved in 6 (25%) patients, good - in 20 (62.5%) children, no changes were registered in 2 and deterioration of myasthenia in 2 (6.25%) patients. The study proved that thoracoscopic thymectomy obtains the radicalism of open technique, proposing the easier postoperative period and being the method of choice for the surgical treatment of myasthenia gravis in children.
Evaluation of salivary surface tension in a cohort of young healthy adults.
Foglio-Bonda, P L; Laguini, E; Davoli, C; Pattarino, F; Foglio-Bonda, A
2018-03-01
To determine salivary pH, flow rate (FR) and surface tension (γs) in a cohort of 30 healthy young adults. To acquire cohort biological independent variables (age, gender, weight, height, medications, smoking, pathologies, and allergies) and to correlate them with pH, FR and γs obtained values. Evaluate the possible variation of the γs values during the time after the withdrawal and the influence of the operational abilities of the experimenting operators. Evaluate the relationship between γs, pH and FR and the dependence between pH and FR. Non-stimulated saliva samples were taken in four different time span, for three days, with a drooling method for 15 minutes. The saliva sample was analyzed, in terms of γs, by two different operators (OP1 and OP2), twice consecutive (γs-1 and γs-2) for a total of 360 measurements. The γs was calculated using the du Noüy method. The FR was evaluated by weighing technique and pH by pH indicator papers. The measurements of γs performed by two different operators (OP1, OP2) showed respectively average values of 46.46 mN/m and 43.45 mN/m, while the mean FR was 0.29 ± 0.13 mL/min and the average pH was 7.1 ± 0.43. There were no significant correlations between γs and the biological variables analyzed. We can consider as reference values, in a sample of young adults, γs 45.56 ± 6.51 mN/m.
Fast track endoscopic thoracic sympathicotomy.
Duarte, João Bosco Vieira; Kux, Peter; Castro, Carlos H V; Cruvinel, Marcos G C; Costa, José R R
2003-12-01
The length of hospital stay is an important factor of cost and psychological discomfort in the treatment of hyperhidrosis by endoscopic thoracic sympathicotomy (ETS). Our experience enrolls 1587 patients operated on an outpatient basis in the last 10 years and seven months. This study aimed to confirm that ETS can be performed on an outpatient basis. Fifty-two consecutive patients (30 males and 22 females) were submitted to ETS under general anesthesia using a single lumen endotracheal tube, with lung collapse by intrapleural injection of CO(2). The sympathetic chain and the communicating rami were severed at different levels according to hyperhidrosis location. Patients were physical state American Society of Anesthesiologists 1 and 2. Age varied between 13 and 55 years (27.3 +/- 10.2 years). They were monitored with ECG, SPO2, NIBP, expired CO(2), sevoflurane analyzer, and airway pressure. Normal saline (40.0 +/- 2.7 ml/kg) was infused intravenously. The drugs used were propofol, alfentanil, rocuronium, ondansetron, dexamethasone, dipyrone, cetoprofene and sevoflurane. Anesthesia and post-operative data were analyzed. Post-operative thoracic X-rays were taken in 20 patients before discharge. Anesthesia lasted 67.2 +/- 20.8 minutes, and the surgical procedure took 46.3 +/- 20.9 minutes. The patients stayed 18.0 +/- 11.0 minutes in the post-anaesthetic care unit and were discharged from hospital after 150.3 +/- 43.1 minutes. The only abnormal post-operative event observed was insignificant residual carbothorax, found in 2 (10%) of the thoracic X-rays taken. In conclusion, this study confirmed that ETS can be performed safely on an outpatient basis.
[Decision Making Experience on Breast Reconstruction for Women with Breast Cancer].
Yi, Myungsun; Joung, Woo Joung; Park, Eun Young; Kwon, Eun Jin; Kim, Haejin; Seo, Ji Young
2016-12-01
The purpose of this study was to explore decision making experiences of Korean women with breast cancer who underwent breast reconstruction with/after a mastectomy. Data were collected during 2015-2016 through individual in-depth interviews with 10 women who had both mastectomy and breast reconstruction, and analyzed using phenomenological method to identify essential themes on experiences of making a decision to have breast reconstruction. Five theme clusters emerged. First, "expected loss of sexuality and discovery of autonomy" illustrates various aims of breast reconstruction. Second, "holding tight to the reputation of doctors amid uncertainty" specifies the importance of a trust relationship with their physician despite a lack of information. Third, "family members to step back in position" describes support or opposition from family members in the decision making process. Fourth, "bewilderment due to the paradox of appearance-oriented views" illustrates paradoxical environment, resulting in confusion and anger. Lastly, "decision to be made quickly with limited time to oneself" describes the crazy whirling process of decision making. Findings highlight aims, worries, barriers, and facilitators that women with breast cancer experience when making a decision about breast reconstruction. Deciding on breast reconstruction was not only a burden for women in a state of shock with a diagnosis of breast cancer, but also an opportunity to decide to integrate their body, femininity, and self which might be wounded from a mastectomy. These findings will help oncology professionals provide effective educational counselling before the operation to promote higher satisfaction after the operation.
Initial experience of single-port laparoscopic surgery for sigmoid colon cancer.
Park, Sun Jin; Lee, Kil Yeon; Kang, Byung Mo; Choi, Sung Il; Lee, Suk Hwan
2013-03-01
Single-port laparoscopic surgery has attracted attention in the field of minimally invasive colorectal surgery. We hypothesized that an experienced laparoscopic surgeon could perform single-port surgery for colon cancer eligible for conventional laparoscopic anterior resection. Our aim was to analyze our initial experience and immediate surgical outcomes of single-port anterior resection. A total of 37 consecutive patients with presumed sigmoid colonic cancer underwent single-port anterior resection with standard laparoscopic instruments between May 2009 and June 2010. Each operation was performed by one of two experienced colorectal surgeons. A cohort of patients who had undergone conventional laparoscopic surgery (CLS) for the same duration a year earlier (August 2007 to September 2008) was used as a historical control. Patient demographics and perioperative outcomes were analyzed and compared with those of CLS. There were no significant differences in mean estimated blood loss, mean length of the resection margin, or morbidity between the two groups, but operative time for the single-port group was significantly shorter (118 ± 41 vs. 140 ± 42 min; p = 0.017). Single-port laparoscopic surgery was successfully performed in 78.4% (29/37) of the patients treated in 2010, and CLS was successfully completed in all of the patients treated the previous year (p = 0.000). The main causes of single-port surgery failure were adhesion and tumor location. Single-port anterior resection is a feasible and safe procedure with immediate outcomes comparable to those of conventional laparoscopy. Further studies are required to determine the feasibility of single-port surgery for colonic tumors outside the sigmoid colon and the long-term outcome.
A Second-Generation Volatile Organic Analyzer for the International Space Station
NASA Technical Reports Server (NTRS)
Limero, Thomas; Reese, Eric; Peters, Randy; James, John T.
1999-01-01
Early in the development of the Crew Health Care System (CHECS) for the International Space Station (ISS), it was recognized that detection of target volatile organic compounds would be a key component of the air monitoring strategy. Experiences during the NASA/Mir program supported the decision to include a real-time volatile organic analyzer (VOA) aboard ISS to help assess the impact of air quality events on crew health and determine the effectiveness of decontamination efforts. Toward this end, a joint development by the Toxicology Laboratory at Johnson Space Center and Graseby Dynamics produced a VOA that has been delivered and is ready for the first 5 years of ISS operation. The first-generation VOA selection criteria included minimizing size, weight, and power consumption while maintaining analytical performance. Measuring available technologies against these criteria, a VOA system based upon gas chromatography/ion mobility spectrometry (GC/IMS) was selected in the mid-90's. However, as NASA looks forward to later-stage ISS operations and to new frontiers such as human exploration of Mars, the ISS VOA (weighing 43 kg and consuming 160 watts) must be replaced by a smaller, less resource-intensive device. This paper will present a possible second-gene ration VOA based upon the same technology as the first-generation unit. Utilizing GC/IMS technology again will permit the instrumental data and experience gained during the initial phase of ISS to be applied to later ISS phases and advanced spacecraft missions. During the past 3 years, efforts to reduce the size of ion mobility spectrometers have been pursued by Graseby Dynamics, the manufacturer of the first-generation VOA. The concept of operation, expected analytical performance, and estimated size of a fully functional second-generation VOA based upon GC/mini-IMS technology will be presented. Furthermore, results of initial laboratory evaluations will be shown.
Huang, Po-Hsin; Chiu, Ming-Chuan
2016-01-01
The Digital Accessible Information SYstem (DAISY) player is an assistive reading tool developed for use by persons with visual impairments. Certain problems have persisted in the operating procedure and interface of DAISY players, especially for their Chinese users. Therefore, the aim of this study was to redesign the DAISY player with increased usability features for use by native Chinese speakers. First, a User Centered Design (UCD) process was employed to analyze the development of the prototype. Next, operation procedures were reorganized according to GOMS (Goals, Operators, Methods, and Selection rules) methodology. Then the user interface was redesigned according to specific Universal Design (UD) principles. Following these revisions, an experiment involving four scenarios was conducted to compare the new prototype to other players, and it was tested by twelve visually impaired participants. Results indicate the prototype had the quickest operating times, the fewest number of operating errors, and the lowest mental workloads of all the compared players, significantly enhancing the prototype's usability. These findings have allowed us to generate suggestions for developing the next generation of DAISY players for people, especially for Chinese audience. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Science Opportunity Analyzer (SOA): Science Planning Made Simple
NASA Technical Reports Server (NTRS)
Streiffert, Barbara A.; Polanskey, Carol A.
2004-01-01
.For the first time at JPL, the Cassini mission to Saturn is using distributed science operations for developing their experiments. Remote scientists needed the ability to: a) Identify observation opportunities; b) Create accurate, detailed designs for their observations; c) Verify that their designs meet their objectives; d) Check their observations against project flight rules and constraints; e) Communicate their observations to other scientists. Many existing tools provide one or more of these functions, but Science Opportunity Analyzer (SOA) has been built to unify these tasks into a single application. Accurate: Utilizes JPL Navigation and Ancillary Information Facility (NAIF) SPICE* software tool kit - Provides high fidelity modeling. - Facilitates rapid adaptation to other flight projects. Portable: Available in Unix, Windows and Linux. Adaptable: Designed to be a multi-mission tool so it can be readily adapted to other flight projects. Implemented in Java, Java 3D and other innovative technologies. Conclusion: SOA is easy to use. It only requires 6 simple steps. SOA's ability to show the same accurate information in multiple ways (multiple visualization formats, data plots, listings and file output) is essential to meet the needs of a diverse, distributed science operations environment.
Task parameters affecting ergonomic demands and productivity of HVAC duct installation.
Mitropoulos, Panagiotis; Hussain, Sanaa; Guarascio-Howard, Linda; Memarian, Babak
2014-01-01
Mechanical installation workers experience work-related musculoskeletal disorders (WMSDs) at high rates. (1) Quantify the ergonomic demands during HVAC installation, (2) identify the tasks and task parameters that generated extreme ergonomic demands, and (3) propose improvements to reduce the WMSDs among mechanical workers. The study focused on installation of rectangular ductwork components using ladders, and analyzed five operations by two mechanical contractors. Using continuous time observational assessment, the videotaped operations were analyzed along two dimensions: (1) the production tasks and durations, and (2) the ergonomic demands for four body regions (neck, arms/shoulders, back, and knees). The analysis identified tasks with low portion of productive time and high portion of extreme postures, and task parameters that generated extreme postures. Duct alignment was the task with the highest portion of extreme postures. The position of the ladder (angle and distance from the duct) was a task parameter that strongly influenced the extreme postures for back, neck and shoulders. Other contributing factors included the difficulty to reach the hand tools when working on the ladder, the congestion of components in the ceiling, and the space between the duct and the ceiling. The identified tasks and factors provide directions for improvement.
Software Analyzes Complex Systems in Real Time
NASA Technical Reports Server (NTRS)
2008-01-01
Expert system software programs, also known as knowledge-based systems, are computer programs that emulate the knowledge and analytical skills of one or more human experts, related to a specific subject. SHINE (Spacecraft Health Inference Engine) is one such program, a software inference engine (expert system) designed by NASA for the purpose of monitoring, analyzing, and diagnosing both real-time and non-real-time systems. It was developed to meet many of the Agency s demanding and rigorous artificial intelligence goals for current and future needs. NASA developed the sophisticated and reusable software based on the experience and requirements of its Jet Propulsion Laboratory s (JPL) Artificial Intelligence Research Group in developing expert systems for space flight operations specifically, the diagnosis of spacecraft health. It was designed to be efficient enough to operate in demanding real time and in limited hardware environments, and to be utilized by non-expert systems applications written in conventional programming languages. The technology is currently used in several ongoing NASA applications, including the Mars Exploration Rovers and the Spacecraft Health Automatic Reasoning Pilot (SHARP) program for the diagnosis of telecommunication anomalies during the Neptune Voyager Encounter. It is also finding applications outside of the Space Agency.
NASA Astrophysics Data System (ADS)
Liu, Hui; Zeng, Ming; Jiang, Wenjia; Yang, Chiyu; Ning, Zhongxi; Yu, Daren
2018-04-01
Due to a special magnetic field structure, the multi-cusped field thruster shows advantages of low wall erosion, low noise and high thrust density over a wide range of thrust. In this paper, expanding discharge channels are employed to make up for deficiencies on the range of thrust and plume divergence, which often emerges in conventional straight cylindrical channels. Three thruster geometries are fabricated with different expanding-angle channels, and a group of experiments are carried out to find out their influence on the performance and discharge characteristics of the thruster. A retarding potential analyzer and a Faraday probe are employed to analyze the structures of the plume in these three models. The results show that when the thrusters operate at low mass flow rate, the gradually-expanding channels exhibit lower propellant utilization and lower overall performance by amounts not exceeding 44.8% in ionization rate and 19.5% in anode efficiency, respectively. But the weakening of magnetic field intensity near the exit of expanding channels leads to an extended thrust throttling ability, a smaller plume divergence angle, and a relatively larger stable operating space without mode converting and the consequent performance degradation.
Zhang, Xiaoxing; Chen, Qinchuan; Tang, Ju; Hu, Weihua; Zhang, Jinbin
2014-01-01
The detection of partial discharge by analyzing the components of SF6 gas in gas-insulated switchgears is important to the diagnosis and assessment of the operational state of power equipment. A gas sensor based on anatase TiO2 is used to detect decomposed gases in SF6. In this paper, first-principle density functional theory calculations are adopted to analyze the adsorption of SO2, SOF2, and SO2F2, the primary decomposition by-products of SF6 under partial discharge, on anatase (101) and (001) surfaces. Simulation results show that the perfect anatase (001) surface has a stronger interaction with the three gases than that of anatase (101), and both surfaces are more sensitive and selective to SO2 than to SOF2 and SO2F2. The selection of a defect surface to SO2, SOF2, and SO2F2 differs from that of a perfect surface. This theoretical result is corroborated by the sensing experiment using a TiO2 nanotube array (TNTA) gas sensor. The calculated values are analyzed to explain the results of the Pt-doped TNTA gas sensor sensing experiment. The results imply that the deposited Pt nanoparticles on the surface increase the active sites of the surface and the gas molecules may decompose upon adsorption on the active sites. PMID:24755845
Parity-time-symmetry enhanced optomechanically-induced-transparency
Li, Wenlin; Jiang, Yunfeng; Li, Chong; Song, Heshan
2016-01-01
We propose and analyze a scheme to enhance optomechanically-induced-transparency (OMIT) based on parity-time-symmetric optomechanical system. Our results predict that an OMIT window which does not exist originally can appear in weak optomechanical coupling and driving system via coupling an auxiliary active cavity with optical gain. This phenomenon is quite different from these reported in previous works in which the gain is considered just to damage OMIT phenomenon even leads to electromagnetically induced absorption or inverted-OMIT. Such enhanced OMIT effects are ascribed to the additional gain which can increase photon number in cavity without reducing effective decay. We also discuss the scheme feasibility by analyzing recent experiment parameters. Our work provide a promising platform for the coherent manipulation and slow light operation, which has potential applications for quantum information processing and quantum optical device. PMID:27489193
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.A. Bamberger; L.M. Liljegren; P.S. Lowery
This document presents an analysis of the mechanisms influencing mixing within double-shell slurry tanks. A research program to characterize mixing of slurries within tanks has been proposed. The research program presents a combined experimental and computational approach to produce correlations describing the tank slurry concentration profile (and therefore uniformity) as a function of mixer pump operating conditions. The TEMPEST computer code was used to simulate both a full-scale (prototype) and scaled (model) double-shell waste tank to predict flow patterns resulting from a stationary jet centered in the tank. The simulation results were used to evaluate flow patterns in the tankmore » and to determine whether flow patterns are similar between the full-scale prototype and an existing 1/12-scale model tank. The flow patterns were sufficiently similar to recommend conducting scoping experiments at 1/12-scale. Also, TEMPEST modeled velocity profiles of the near-floor jet were compared to experimental measurements of the near-floor jet with good agreement. Reported values of physical properties of double-shell tank slurries were analyzed to evaluate the range of properties appropriate for conducting scaled experiments. One-twelfth scale scoping experiments are recommended to confirm the prioritization of the dimensionless groups (gravitational settling, Froude, and Reynolds numbers) that affect slurry suspension in the tank. Two of the proposed 1/12-scale test conditions were modeled using the TEMPEST computer code to observe the anticipated flow fields. This information will be used to guide selection of sampling probe locations. Additional computer modeling is being conducted to model a particulate laden, rotating jet centered in the tank. The results of this modeling effort will be compared to the scaled experimental data to quantify the agreement between the code and the 1/12-scale experiment. The scoping experiment results will guide selection of parameters to be varied in the follow-on experiments. Data from the follow-on experiments will be used to develop correlations to describe slurry concentration profile as a function of mixing pump operating conditions. This data will also be used to further evaluate the computer model applications. If the agreement between the experimental data and the code predictions is good, the computer code will be recommended for use to predict slurry uniformity in the tanks under various operating conditions. If the agreement between the code predictions and experimental results is not good, the experimental data correlations will be used to predict slurry uniformity in the tanks within the range of correlation applicability.« less
Asia tsunami disaster 2004: experience at three international airports.
Deebaj, Richard; Castrén, Maaret; Gunnar, Ohlén
2011-02-01
On 26 December 2004, a large earthquake in the Indian Ocean and the resulting tsunami created a disaster on a scale unprecedented in recorded history. Thousands of foreign tourists, predominantly Europeans, were affected. Their governments were required to organize rapid rescue responses for a catastrophe thousands of miles away, something for which they had little or no experience. The rescue operations at three international airports in Sweden, the UK, and Finland are analyzed with emphasis on "lessons learned" and recommendations for future similar rescue efforts. This report is based on interviews with and unpublished reports from medical personnel involved in the rescue operations at the three airports, as well as selected references from an electronic literature search. In the period immediately following the tsunami, tens of thousands of Swedes, Britons, and Finns returned home from the affected areas in Southeast Asia. More than 7,800, 104, and approximately 3,700 casualties from Sweden, the UK, and Finland, respectively, received medical and/or psychological care at the temporary medical clinics organized at the home airports. Psychiatric presentations and soft tissue and orthopedic injuries predominated. All three airport medical operations suffered from the lack of a national catastrophe plan that addressed the contingency of a natural or disaster due to a natural or man-made project occurring outside the country's borders involving a large number of its citizens. While the rescue operations at the three airports functioned variably well, much of the success could be attributed to individual initiative and impromptu problem-solving. Anticipation of the psychological and aftercare needs of all those involved contributed to the relative effectiveness of the Finnish and Swedish operations.
Ikegami, Hiroko; Kawawa, Rie; Ichi, Ikuyo; Ishikawa, Tomoko; Koike, Taisuke; Aoki, Yoshinori; Fujiwara, Yoko
2017-10-01
Background: Animal studies on the effects of vitamin E on bone health have yielded conflicting and inconclusive results, and to our knowledge, no studies have addressed the effect of vitamin E on bone in animals consuming a high-fat diet (HFD). Objective: This study aimed to evaluate the effect of excessive vitamin E on bone metabolism in normal male mice and ovariectomized female mice fed a normal diet (ND) or HFD. Methods: In the first 2 experiments, 7-wk-old male mice were fed an ND (16% energy from fat) containing 75 (control), 0 (vitamin E-free), or 1000 (high vitamin E) mg vitamin E/kg (experiment 1) or an HFD (46% energy from fat) containing 0, 200, 500, or 1000 mg vitamin E/kg (experiment 2) for 18 wk. In the third experiment, 7-wk-old sham-operated or ovariectomized female mice were fed the ND (75 mg vitamin E/kg) or HFD containing 0 or 1000 mg vitamin E/kg for 8 wk. At the end of the feeding period, blood and femurs were collected to measure bone turnover markers and analyze histology and microcomputed tomography. Results: In experiments 1 and 2, vitamin E intake had no effect on plasma alkaline phosphatase (ALP), tartrate-resistant acid phosphatase (TRAP) activity, or bone formation, resorption, or volume in femurs in mice fed the ND or HFDs. In experiment 3, bone volume was significantly reduced (85%) in ovariectomized mice compared with that in sham-operated mice ( P < 0.05), but it did not differ among mice fed the 3 diets. Plasma ALP and TRAP activities and bone formation and resorption in femur were similar among ovariectomized mice fed the HFD containing 0 or 1000 mg vitamin E/kg. Conclusions: The results suggest that excess vitamin E intake does not cause bone loss in normal male mice or in ovariectomized or sham-operated female mice, regardless of dietary fat content. © 2017 American Society for Nutrition.
Witnessing entanglement without entanglement witness operators
Pezzè, Luca; Li, Yan; Li, Weidong; Smerzi, Augusto
2016-01-01
Quantum mechanics predicts the existence of correlations between composite systems that, although puzzling to our physical intuition, enable technologies not accessible in a classical world. Notwithstanding, there is still no efficient general method to theoretically quantify and experimentally detect entanglement of many qubits. Here we propose to detect entanglement by measuring the statistical response of a quantum system to an arbitrary nonlocal parametric evolution. We witness entanglement without relying on the tomographic reconstruction of the quantum state, or the realization of witness operators. The protocol requires two collective settings for any number of parties and is robust against noise and decoherence occurring after the implementation of the parametric transformation. To illustrate its user friendliness we demonstrate multipartite entanglement in different experiments with ions and photons by analyzing published data on fidelity visibilities and variances of collective observables. PMID:27681625
On entanglement of light and Stokes parameters
NASA Astrophysics Data System (ADS)
Żukowski, Marek; Laskowski, Wiesław; Wieśniak, Marcin
2016-08-01
We present a new approach to Stokes parameters, which enables one to see better non-classical properties of bright quantum light, and of undefined overall photon numbers. The crucial difference is as follows. The standard quantum optical Stokes parameters are averages of differences of intensities of light registered at the two exits of polarization analyzers, and one gets their normalized version by dividing them by the average total intensity. The new ones are averages of the registered normalized Stokes parameters, for the duration of the experiment. That is, we redefine each Stokes observable as the difference of photon number operators at the two exits of a polarizing beam splitter multiplied by the inverse of their sum. The vacuum eigenvalue of the operator is defined a zero. We show that with such an approach one can obtain more sensitive entanglement indicators based on polarization measurements.
NASA Astrophysics Data System (ADS)
Zhao, L.; Boehmer, H.; Edrich, D.; Heidbrink, W. W.; McWilliams, R.; Leneman, D.
2002-11-01
To measure the fast-ion transport as a function of gyroradius, a 3-cm diameter, 17 MHz, ˜ 80 W, ˜ 3 mA, argon source is under development for use in the LArge Plasma Device (LAPD). In tests on the Irvine Mirror, the source performs reliably when oriented either parallel to the magnetic field or at an oblique angle and in either a CW or pulsed mode of operation. A radial energy analyzer measures the profile of the 200-500 eV beam. Laser-induced fluorescence (LIF) of cold 3d^2G_9/2 argon metastables excited by the source is readily measured but the hot argon ions in the beam itself are more difficult to detect. In preliminary tests on LAPD, the source operated successfully. Planned physics experiments include measurements of collisional fast-ion diffusion and fluctuation-induced transport.
Thirumala, Parthasarathy D; Krishnaiah, Balaji; Habeych, Miguel E; Balzer, Jeffrey R; Crammond, Donald J
2015-04-01
The primary aim of this paper is to study the pre-operative characteristics, intra-operative changes and post-operative hearing outcomes in patients after complete loss of wave V of the brainstem auditory evoked potential. We retrospectively analyzed the brainstem auditory evoked potential data of 94 patients who underwent microvascular decompression for hemifacial spasm at our institute. Patients were divided into two groups - those with and those without loss of wave V. The differences between the two groups and outcomes were assessed using t-test and chi-squared tests. In our study 23 (24%) patients out of 94 had a complete loss of wave V, with 11 (48%) patients experiencing transient loss and 12 (52%) patients experiencing permanent loss. The incidence of hearing loss in patients with no loss of wave V was 5.7% and 26% in patients who did experience wave V loss. The incidence of hearing change in patients with no loss of wave V was 12.6% and 30.43% in patients who did experience wave V loss. Loss of wave V during the procedure or at the end of procedure significantly increases the odds of hearing loss. Hearing change is a significant under-reported clinical condition after microvascular decompression in patients who have loss of wave V. Copyright © 2014 Elsevier Ltd. All rights reserved.
Graph-cut based discrete-valued image reconstruction.
Tuysuzoglu, Ahmet; Karl, W Clem; Stojanovic, Ivana; Castañòn, David; Ünlü, M Selim
2015-05-01
Efficient graph-cut methods have been used with great success for labeling and denoising problems occurring in computer vision. Unfortunately, the presence of linear image mappings has prevented the use of these techniques in most discrete-amplitude image reconstruction problems. In this paper, we develop a graph-cut based framework for the direct solution of discrete amplitude linear image reconstruction problems cast as regularized energy function minimizations. We first analyze the structure of discrete linear inverse problem cost functions to show that the obstacle to the application of graph-cut methods to their solution is the variable mixing caused by the presence of the linear sensing operator. We then propose to use a surrogate energy functional that overcomes the challenges imposed by the sensing operator yet can be utilized efficiently in existing graph-cut frameworks. We use this surrogate energy functional to devise a monotonic iterative algorithm for the solution of discrete valued inverse problems. We first provide experiments using local convolutional operators and show the robustness of the proposed technique to noise and stability to changes in regularization parameter. Then we focus on nonlocal, tomographic examples where we consider limited-angle data problems. We compare our technique with state-of-the-art discrete and continuous image reconstruction techniques. Experiments show that the proposed method outperforms state-of-the-art techniques in challenging scenarios involving discrete valued unknowns.
A Simple and Automatic Method for Locating Surgical Guide Hole
NASA Astrophysics Data System (ADS)
Li, Xun; Chen, Ming; Tang, Kai
2017-12-01
Restoration-driven surgical guides are widely used in implant surgery. This study aims to provide a simple and valid method of automatically locating surgical guide hole, which can reduce operator's experiences and improve the design efficiency and quality of surgical guide. Few literatures can be found on this topic and the paper proposed a novel and simple method to solve this problem. In this paper, a local coordinate system for each objective tooth is geometrically constructed in CAD system. This coordinate system well represents dental anatomical features and the center axis of the objective tooth (coincide with the corresponding guide hole axis) can be quickly evaluated in this coordinate system, finishing the location of the guide hole. The proposed method has been verified by comparing two types of benchmarks: manual operation by one skilled doctor with over 15-year experiences (used in most hospitals) and automatic way using one popular commercial package Simplant (used in few hospitals).Both the benchmarks and the proposed method are analyzed in their stress distribution when chewing and biting. The stress distribution is visually shown and plotted as a graph. The results show that the proposed method has much better stress distribution than the manual operation and slightly better than Simplant, which will significantly reduce the risk of cervical margin collapse and extend the wear life of the restoration.
40 CFR 89.319 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... start-up and basic operating adjustment using the appropriate fuel (see § 89.312(e)) and zero-grade air... flow. Heated Flame Ionization Detectors (HFIDs) must be at their specified operating temperature. One.... (1) Adjust analyzer to optimize performance. (2) Zero the hydrocarbon analyzer with zero-grade air...
40 CFR 90.320 - Carbon dioxide analyzer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... use and monthly thereafter, or within one month prior to the certification test, calibrate the NDIR... operation. Adjust the analyzer to optimize performance. (2) Zero the carbon dioxide analyzer with either purified synthetic air or zero-grade nitrogen. (3) Calibrate on each normally used operating range with...
[Short-term efficacy of da Vinci robotic surgical system on rectal cancer in 101 patients].
Zeng, Dong-Zhu; Shi, Yan; Lei, Xiao; Tang, Bo; Hao, Ying-Xue; Luo, Hua-Xing; Lan, Yuan-Zhi; Yu, Pei-Wu
2013-05-01
To investigate the feasibility and safety of da Vinci robotic surgical system in rectal cancer radical operation, and to summarize its short-term efficacy and clinical experience. Data of 101 cases undergoing da Vinci robotic surgical system for rectal cancer radical operation from March 2010 to September 2012 were retrospectively analyzed. Evaluation was focused on operative procedure, complication, recovery and pathology. All the 101 cases underwent operation successfully and safely without conversion to open procedure. Rectal cancer radical operation with da Vinci robotic surgical system included 73 low anterior resections and 28 abdominoperineal resections. The average operative time was (210.3±47.2) min. The average blood lose was (60.5±28.7) ml without transfusion. Lymphadenectomy harvest was 17.3±5.4. Passage of first flatus was (2.7±0.7) d. Distal margin was (5.3±2.3) cm without residual cancer cells. The complication rate was 6.9%, including anastomotic leakage(n=2), perineum incision infection(n=2), pulmonary infection (n=2), urinary retention (n=1). There was no postoperative death. The mean follow-up time was(12.9±8.0) months. No local recurrence was found except 2 cases with distant metastasis. Application of da Vinci robotic surgical system in rectal cancer radical operation is safe and patients recover quickly The short-term efficacy is satisfactory.
Validation of TGLF in C-Mod and DIII-D using machine learning and integrated modeling tools
NASA Astrophysics Data System (ADS)
Rodriguez-Fernandez, P.; White, Ae; Cao, Nm; Creely, Aj; Greenwald, Mj; Grierson, Ba; Howard, Nt; Meneghini, O.; Petty, Cc; Rice, Je; Sciortino, F.; Yuan, X.
2017-10-01
Predictive models for steady-state and perturbative transport are necessary to support burning plasma operations. A combination of machine learning algorithms and integrated modeling tools is used to validate TGLF in C-Mod and DIII-D. First, a new code suite, VITALS, is used to compare SAT1 and SAT0 models in C-Mod. VITALS exploits machine learning and optimization algorithms for the validation of transport codes. Unlike SAT0, the SAT1 saturation rule contains a model to capture cross-scale turbulence coupling. Results show that SAT1 agrees better with experiments, further confirming that multi-scale effects are needed to model heat transport in C-Mod L-modes. VITALS will next be used to analyze past data from DIII-D: L-mode ``Shortfall'' plasma and ECH swing experiments. A second code suite, PRIMA, allows for integrated modeling of the plasma response to Laser Blow-Off cold pulses. Preliminary results show that SAT1 qualitatively reproduces the propagation of cold pulses after LBO injections and SAT0 does not, indicating that cross-scale coupling effects play a role in the plasma response. PRIMA will be used to ``predict-first'' cold pulse experiments using the new LBO system at DIII-D, and analyze existing ECH heat pulse data. Work supported by DE-FC02-99ER54512, DE-FC02-04ER54698.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Villanueva, J. F.; Carlos, S.; Martorell, S.
The loss of the residual heat removal system in mid-loop conditions may occur with a non-negligible contribution to the plant risk, so the analysis of the accidental sequences and the actions to mitigate the accident are of great interest in shutdown conditions. In order to plan the appropriate measures to mitigate the accident is necessary to understand the thermal-hydraulic processes following the loss of the residual heat removal system during shutdown. Thus, transients of this kind have been simulated using best-estimate codes in different integral test facilities and compared with experimental data obtained in different facilities. In PKL (Primaerkreislauf-Versuchsanlage, primarymore » coolant loop test facility) test facility different series of experiments have been undertaken to analyze the plant response in shutdown. In this context, the E3 and F2 series consist of analyzing the loss of the residual heat removal system with a reduced inventory in the primary system. In particular, the experiments were developed to investigate the influence of the steam generators secondary side configuration on the plant response, what involves the consideration of different number of steam generators filled with water and ready for activation, on the heat transfer mechanisms inside the steam generators U-tubes. This work presents the results of such experiments calculated using, RELAP5/Mod 3.3. (authors)« less
Dynamic System Simulation of the KRUSTY Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Steven Karl; Kimpland, Robert Herbert
2016-05-09
The proposed KRUSTY experiment is a demonstration of a reactor operating at power. The planned experimental configuration includes a highly enriched uranium (HEU) reflected core, cooled by multiple heat pipes leading to Stirling engines for primary heat rejection. Operating power is expected to be approximately four (4) to five (5) kilowatts with a core temperature above 1,000 K. No data is available on any historical reactor employing HEU metal that operated over the temperature range required for the KRUSTY experiment. Further, no reactor has operated with heat pipes as the primary cooling mechanism. Historic power reactors have employed either naturalmore » or forced convection so data on their operation is not directly applicable to the KRUSTY experiment. The primary purpose of the system model once developed and refined by data from these component experiments, will be used to plan the KRUSTY experiment. This planning will include expected behavior of the reactor from start-up, through various transient conditions where cooling begins to become present and effective, and finally establishment of steady-state. In addition, the model can provide indicators of anticipated off-normal events and appropriate operator response to those conditions. This information can be used to develop specific experiment operating procedures and aids to guide the operators in conduct of the experiment.« less
Foran, Paula
2016-01-01
The aim of this research was to determine if guided operating theatre experience in the undergraduate nursing curricula enhanced surgical knowledge and understanding of nursing care provided outside this specialist area in the pre- and post-operative surgical wards. Using quantitative analyses, undergraduate nurses were knowledge tested on areas of pre- and post-operative surgical nursing in their final semester of study. As much learning occurs in nurses' first year of practice, participants were re-tested again after their Graduate Nurse Program/Preceptorship year. Participants' results were compared to the model of operating room education they had participated in to determine if there was a relationship between the type of theatre education they experienced (if any) and their knowledge of surgical ward nursing. Findings revealed undergraduates nurses receiving guided operating theatre experience had a 76% pass rate compared to 56% with non-guided or no experience (p < 0.001). Graduates with guided operating theatre experience as undergraduates or graduate nurses achieved a 100% pass rate compared to 53% with non-guided or no experience (p < 0.001). The research informs us that undergraduate nurses achieve greater learning about surgical ward nursing via guided operating room experience as opposed to surgical ward nursing experience alone. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Rendering surgical care to wounded with neck wounds in an armed conflict].
Samokhvalov, I M; Zavrazhnov, A A; Fakhrutdinov, A M; Sychev, M I
2001-10-01
The results of rendering of the medical care (the first aid, qualified and specialized) obtained in 172 servicemen with neck injuries who stayed in Republic of Chechnya during the period from 09.08.1999 to 28.07.2000 were analyzed. Basing on the results of analysis and experience of casualties' treatment the authors discuss the problems of sequence and volume of surgical care in this group of casualties with reference to available medical evacuation system, surgical tactics at the stage of specialized care. They also consider the peculiarities of operative treatment of the casualties with neck injuries.
Rylov, A I; Kravets, N S
2001-01-01
The experience of treatment of 69 injured persons with posttraumatic retroperitoneal hematoma suffering severe multiple combined abdominal trauma was analyzed. Application of the classification proposed permits to formulate diagnosis and to choose the tactic of treatment correctly. The intraoperative tactics algorithm was elaborated. It promotes the correct analysis of intraoperative findings and reduction of the diagnostic mistakes frequency as well. In the presence of vast defect, making impossible to suture over the parietal peritoneum, extraperitonization using cerebral dura mater was done. Operative intervention was concluded by drainage with subsequent laserotherapy.
Vehicle Charging And Potential (VCAP)
NASA Astrophysics Data System (ADS)
Roberts, B.
1986-01-01
The vehicle charging and potential (VCAP) payload includes a small electron accelerator capable of operating in a pulsed mode with firing pulses ranging from 600 nanoseconds to 107 seconds (100 milliamps at 1000 volts), a spherical retarding potential analyzer - Langmuir probe, and charge current probes. This instrumentation will support studies of beam plasma interactions and the electrical charging of the spacecraft. Active experiments may also be performed to investigate the fundamental processes of artificial aurora and ionospheric perturbations. In addition, by firing the beam up the geomagnetic field lines of force (away from the Earth) investigations of parallel electric field may be performed.
Vehicle Charging And Potential (VCAP)
NASA Astrophysics Data System (ADS)
Roberts, W. T.
The vehicle charging and potential (VCAP) payload includes a small electron accelerator capable of operating in a pulsed mode with firing pulses ranging from 600 nanoseconds to 107 seconds (100 milliamps at 1000 volts), a spherical retarding potential analyzer - Langmuir probe, and charge current probes. This instrumentation will support studies of beam plasma interactions and the electrical charging of the spacecraft. Active experiments may also be performed to investigate the fundamental processes of artificial aurora and ionospheric perturbations. In addition, by firing the beam up the geomagnetic field lines of force (away from the Earth) investigations of parallel electric field may be performed.
Issues in advanced automation for manipulator control
NASA Technical Reports Server (NTRS)
Bejczy, A. K.
1976-01-01
This paper provides a brief description and analysis of the main issues in advanced autonomous control of manipulators as seen from a system point of view. The nature of manipulation is analyzed at some depth. A general multilevel structure is outlined for manipulator control organization which includes the human operator at the top level of the control structure. Different approaches to the development of advanced automation of mechanical arms are summarized. Recent work in the JPL teleoperator project is described, including control system, force/torque sensor, and control software development. Some results from control experiments are summarized.
A microcomputer-based whole-body counter for personnel routine monitoring.
Chou, H P; Tsai, T M; Lan, C Y
1993-05-01
The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.
NASA Astrophysics Data System (ADS)
Nakatani, T.; Inamura, Y.; Moriyama, K.; Ito, T.; Muto, S.; Otomo, T.
Neutron scattering can be a powerful probe in the investigation of many phenomena in the materials and life sciences. The Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC) is a leading center of experimental neutron science and boasts one of the most intense pulsed neutron sources in the world. The MLF currently has 18 experimental instruments in operation that support a wide variety of users from across a range of research fields. The instruments include optical elements, sample environment apparatus and detector systems that are controlled and monitored electronically throughout an experiment. Signals from these components and those from the neutron source are converted into a digital format by the data acquisition (DAQ) electronics and recorded as time-tagged event data in the DAQ computers using "DAQ-Middleware". Operating in event mode, the DAQ system produces extremely large data files (˜GB) under various measurement conditions. Simultaneously, the measurement meta-data indicating each measurement condition is recorded in XML format by the MLF control software framework "IROHA". These measurement event data and meta-data are collected in the MLF common storage and cataloged by the MLF Experimental Database (MLF EXP-DB) based on a commercial XML database. The system provides a web interface for users to manage and remotely analyze experimental data.
NASA Astrophysics Data System (ADS)
Brock, Ryan J.
Nature deficit, where disconnections occur between children and nature have come to the forefront of environmental education in recent years. This study explored how fourth graders in an after-school Nature Club developed or strengthened their environmental identity, thus decreasing nature deficit. Through a program that utilized semi-formal instruction, both classroom learning and direct experiences with nature, took place over a nine week period of time. Six children were followed as qualitative data was collected and analyzed for themes that would reveal how adolescent children in the developmental stage of concrete operations developed environmental identity. The results indicate that all students strengthened their environmental identity when social aspects were embedded. Students who entered Nature Club with low environmental identity required more direct experiences with nature while those with higher environmental identity required a combination of reflective components along with nature experiences. Based upon this study, the nine-week program which combined formal and non-formal means of learning was able to strengthen environmental identity in each of the participants. A strong theme of social learning, not explicitly identified in the literature was found. Additionally, and most importantly, findings also indicate that educators, both formal and non-formal, who teach environmental education and seek to strengthen environmental identity for adolescents for early interventions need to understand the development of environmental identity in concrete operational learners at a theoretical level.
Nasopharyngeal angiofibroma: Our experience and literature review
Martins, Mariane Barreto Brandão; de Lima, Francis Vinicius Fontes; Mendonça, Carlos Alberto; de Jesus, Eduardo Passos Fiel; Santos, Arlete Cristina Granizo; Barreto, Valéria Maria Prado; Santos, Ronaldo Carvalho
2013-01-01
Summary Introduction: Juvenile nasopharyngeal angiofibroma is a rare, highly vascular, and histologically benign tumor, generally observed in male adolescents. It shows very aggressive behavior due to local invasiveness and is associated with various symptoms. Juvenile nasopharyngeal angiofibroma originates in the sphenopalatine forame, causing epistaxes and nasal obstruction. Objective: To retrospectively describe our experience in the diagnosis and treatment of patients with juvenile nasopharyngeal angiofibroma. Scientific drawing: Retrospective, descriptive study conducted after approval from the Ethics Committee of the Federal University of Sergipe (protocol 0114.0.107.000 -11). Methods: We analyzed findings in 20 patients who underwent surgery between 2004 and 2011. Factors analyzed include patient age and gender, symptoms, stages, treatment, length of surgery, intraoperatory bleeding, postoperative need for nasal tampons, hospitalization time, complications, and tumor recurrence. Results: Patients were aged 10–29 years. All patients were treated surgically, including 17 who underwent endoscopic surgery. The mean operation time was 120 min, and the mean bleeding volume was 300 mL. Seventeen patients required clamping of the external carotids and tumor embolization. Conclusion: Endoscopic surgery alone or with other conventional techniques was safe for the treatment of angiofibromas of different stages. PMID:25991988
Enabling Health Reform through Regional Health Information Exchange: A Model Study from China
Wen, Dong; Meng, Qun
2017-01-01
Objective. To investigate and share the major challenges and experiences of building a regional health information exchange system in China in the context of health reform. Methods. This study used interviews, focus groups, a field study, and a literature review to collect insights and analyze data. The study examined Xinjin's approach to developing and implementing a health information exchange project, using exchange usage data for analysis. Results. Within three years and after spending approximately $2.4 million (15 million RMB), Xinjin County was able to build a complete, unified, and shared information system and many electronic health record components to integrate and manage health resources for 198 health institutions in its jurisdiction, thus becoming a model of regional health information exchange for facilitating health reform. Discussion. Costs, benefits, experiences, and lessons were discussed, and the unique characteristics of the Xinjin case and a comparison with US cases were analyzed. Conclusion. The Xinjin regional health information exchange system is different from most of the others due to its government-led, government-financed approach. Centralized and coordinated efforts played an important role in its operation. Regional health information exchange systems have been proven critical for meeting the global challenges of health reform. PMID:29065565
Measurements by a Vector Network Analyzer at 325 to 508 GHz
NASA Technical Reports Server (NTRS)
Fung, King Man; Samoska, Lorene; Chattopadhyay, Goutam; Gaier, Todd; Kangaslahti, Pekka; Pukala, David; Lau, Yuenie; Oleson, Charles; Denning, Anthony
2008-01-01
Recent experiments were performed in which return loss and insertion loss of waveguide test assemblies in the frequency range from 325 to 508 GHz were measured by use of a swept-frequency two-port vector network analyzer (VNA) test set. The experiments were part of a continuing effort to develop means of characterizing passive and active electronic components and systems operating at ever increasing frequencies. The waveguide test assemblies comprised WR-2.2 end sections collinear with WR-3.3 middle sections. The test set, assembled from commercially available components, included a 50-GHz VNA scattering- parameter test set and external signal synthesizers, augmented with recently developed frequency extenders, and further augmented with attenuators and amplifiers as needed to adjust radiofrequency and intermediate-frequency power levels between the aforementioned components. The tests included line-reflect-line calibration procedures, using WR-2.2 waveguide shims as the "line" standards and waveguide flange short circuits as the "reflect" standards. Calibrated dynamic ranges somewhat greater than about 20 dB for return loss and 35 dB for insertion loss were achieved. The measurement data of the test assemblies were found to substantially agree with results of computational simulations.
Zhao, Jianhu; Zhang, Hongmei; Wang, Shiqi
2017-01-01
Multibeam echosounder systems (MBES) can record backscatter strengths of gas plumes in the water column (WC) images that may be an indicator of possible occurrence of gas at certain depths. Manual or automatic detection is generally adopted in finding gas plumes, but frequently results in low efficiency and high false detection rates because of WC images that are polluted by noise. To improve the efficiency and reliability of the detection, a comprehensive detection method is proposed in this paper. In the proposed method, the characteristics of WC background noise are first analyzed and given. Then, the mean standard deviation threshold segmentations are respectively used for the denoising of time-angle and depth-angle images, an intersection operation is performed for the two segmented images to further weaken noise in the WC data, and the gas plumes in the WC data are detected from the intersection image by the morphological constraint. The proposed method was tested by conducting shallow-water and deepwater experiments. In these experiments, the detections were conducted automatically and higher correct detection rates than the traditional methods were achieved. The performance of the proposed method is analyzed and discussed. PMID:29186014
Assessment of Psychophysiological Response and Specific Fine Motor Skills in Combat Units.
Sánchez-Molina, Joaquín; Robles-Pérez, José J; Clemente-Suárez, Vicente J
2018-03-02
Soldiers´ training and experience can influence the outcome of the missions, as well as their own physical integrity. The objective of this research was to analyze the psycho-physiological response and specific motor skills in an urban combat simulation with two units of infantry with different training and experience. psychophysiological parameters -Heart Rate, blood oxygen saturation, glucose and blood lactate, cortical activation, anxiety and heart rate variability-, as well as fine motor skills were analyzed in 31 male soldiers of the Spanish Army, 19 belonging to the Light Infantry Brigade, and 12 to the Heavy Forces Infantry Brigade, before and after an urban combat simulation. A combat simulation provokes an alteration of the psycho-physiological basal state in soldiers and a great unbalance in the sympathetic-vagal interaction. The specific training of Light Infantry unit involves lower metabolic, cardiovascular, and anxiogenic response not only previous, but mainly after a combat maneuver, than Heavy Infantry unit's. No differences were found in relation with fine motor skills, improving in both cases after the maneuver. This fact should be taken into account for betterment units´ deployment preparation in current theaters of operations.
NASA Astrophysics Data System (ADS)
Penna, James; Morgan, Kyle; Grubb, Isaac; Jarboe, Thomas
2017-10-01
The Helicity Injected Torus - Steady Inductive 3 (HIT-SI3) experiment forms and maintains spheromaks via Steady Inductive Helicity Injection (SIHI) using discrete injectors that inject magnetic helicity via a non-axisymmetric perturbation and drive toroidally symmetric current. Newer designs for larger SIHI-driven spheromaks incorporate a set of injectors connected to a single external manifold to allow more freedom for the toroidal structure of the applied perturbation. Simulations have been carried out using the NIMROD code to assess the effectiveness of various imposed mode structures and injector schema in driving current via Imposed Dynamo Current Drive (IDCD). The results are presented here for varying flux conserver shapes on a device approximately 1.5 times larger than the current HIT-SI3 experiment. The imposed mode structures and spectra of simulated spheromaks are analyzed in order to examine magnetic structure and stability and determine an optimal regime for IDCD sustainment in a large device. The development of scaling laws for manifold operation is also presented, and simulation results are analyzed and assessed as part of the development path for the large scale device.
NASA Technical Reports Server (NTRS)
Jules, Kenol; McPherson, Kevin; Hrovat, Kenneth; Kelly, Eric; Reckart, Timothy
2004-01-01
A primary objective of the International Space Station is to provide a long-term quiescent environment for the conduct of scientific research for a variety of microgravity science disciplines. Since continuous human presence on the space station began in November 2000 through the end of Increment-6, over 1260 hours of crew time have been allocated to research. However, far more research time has been accumulated by experiments controlled on the ground. By the end of the time period covered by this paper (end of Increment-6), the total experiment hours performed on the station are well over 100,000 hours (Expedition 6 Press Kit: Station Begins Third Year of Human Occupation, Boeing/USA/NASA, October 25, 2002). This paper presents the results of the on-going effort by the Principal Investigator Microgravity Services project, at NASA Glenn Research Center, in Cleveland, Ohio, to characterize the microgravity environment of the International Space Station in order to keep the microgravity scientific community apprised of the reduced gravity environment provided by the station for the performance of space experiments. This paper focuses on the station microgravity environment for Increments 5 and 6. During that period over 580 Gbytes of acceleration data were collected, out of which over 34,790 hours were analyzed. The results presented in this paper are divided into two sections: quasi-steady and vibratory. For the quasi-steady analysis, over 7794 hours of acceleration data were analyzed, while over 27,000 hours were analyzed for the vibratory analysis. The results of the data analysis are presented in this paper in the form of a grand summary for the period under consideration. For the quasi-steady acceleration response, results are presented in the form of a 95% confidence interval for the station during "normal microgravity mode operations" for the following three attitudes: local vertical local horizontal, X-axis perpendicular to the orbit plane and the Russian torque equilibrium attitude. The same analysis was performed for the station during "non-microgravity mode operations" to assess the station quasi-steady acceleration environment over a long period of time. The same type of analysis was performed for the vibratory, but a 95th percentile benchmark was used, which shows the overall acceleration magnitude during Increments 5 and 6. The results, for both quasi-steady and vibratory acceleration response, show that the station is not yet meeting the microgravity requirements during the microgravity mode operations. However, it should be stressed that the requirements apply only at assembly complete, whereas the results presented below apply up to the station's configuration at the end of Increment-6. c2004 Elsevier Ltd. All rights reserved.
Incipient fault feature extraction of rolling bearings based on the MVMD and Teager energy operator.
Ma, Jun; Wu, Jiande; Wang, Xiaodong
2018-06-04
Aiming at the problems that the incipient fault of rolling bearings is difficult to recognize and the number of intrinsic mode functions (IMFs) decomposed by variational mode decomposition (VMD) must be set in advance and can not be adaptively selected, taking full advantages of the adaptive segmentation of scale spectrum and Teager energy operator (TEO) demodulation, a new method for early fault feature extraction of rolling bearings based on the modified VMD and Teager energy operator (MVMD-TEO) is proposed. Firstly, the vibration signal of rolling bearings is analyzed by adaptive scale space spectrum segmentation to obtain the spectrum segmentation support boundary, and then the number K of IMFs decomposed by VMD is adaptively determined. Secondly, the original vibration signal is adaptively decomposed into K IMFs, and the effective IMF components are extracted based on the correlation coefficient criterion. Finally, the Teager energy spectrum of the reconstructed signal of the effective IMF components is calculated by the TEO, and then the early fault features of rolling bearings are extracted to realize the fault identification and location. Comparative experiments of the proposed method and the existing fault feature extraction method based on Local Mean Decomposition and Teager energy operator (LMD-TEO) have been implemented using experimental data-sets and a measured data-set. The results of comparative experiments in three application cases show that the presented method can achieve a fairly or slightly better performance than LMD-TEO method, and the validity and feasibility of the proposed method are proved. Copyright © 2018. Published by Elsevier Ltd.
Svrakic, Maja; Roland, J. Thomas; McMenomey, Sean O.; Svirsky, Mario A.
2016-01-01
OBJECTIVE To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE) STUDY DESIGN Retrospective review. SETTING Tertiary referral center. PATIENTS Sixty-three MSE implants in pediatric and adult patients were compared to age- and gender-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. INTERVENTION Cochlear implantation with either the AB 1j electrode or the AB MSE. MAIN OUTCOME MEASURES The MSE and 1j electrode were compared in their angular depth of insertion (aDOI) and pre- to post-operative change in hearing thresholds. Hearing preservation was analyzed as a function of aDOI. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. RESULTS Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2,000 Hz were 10 dB, 7 dB, 2 dB and 6 dB smaller for the MSE electrode than for the 1j (p<0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. CONCLUSIONS The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect. PMID:27755356
First 101 Robotic General Surgery Cases in a Community Hospital
Robertson, Jarrod C.; Alrajhi, Sharifah
2016-01-01
Background and Objectives: The general surgeon's robotic learning curve may improve if the experience is classified into categories based on the complexity of the procedures in a small community hospital. The intraoperative time should decrease and the incidence of complications should be comparable to conventional laparoscopy. The learning curve of a single robotic general surgeon in a small community hospital using the da Vinci S platform was analyzed. Methods: Measured parameters were operative time, console time, conversion rates, complications, surgical site infections (SSIs), surgical site occurrences (SSOs), length of stay, and patient demographics. Results: Between March 2014 and August 2015, 101 robotic general surgery cases were performed by a single surgeon in a 266-bed community hospital, including laparoscopic cholecystectomies, inguinal hernia repairs; ventral, incisional, and umbilical hernia repairs; and colorectal, foregut, bariatric, and miscellaneous procedures. Ninety-nine of the cases were completed robotically. Seven patients were readmitted within 30 days. There were 8 complications (7.92%). There were no mortalities and all complications were resolved with good outcomes. The mean operative time was 233.0 minutes. The mean console operative time was 117.6 minutes. Conclusion: A robotic general surgery program can be safely implemented in a small community hospital with extensive training of the surgical team through basic robotic skills courses as well as supplemental educational experiences. Although the use of the robotic platform in general surgery could be limited to complex procedures such as foregut and colorectal surgery, it can also be safely used in a large variety of operations with results similar to those of conventional laparoscopy. PMID:27667913
First 101 Robotic General Surgery Cases in a Community Hospital.
Oviedo, Rodolfo J; Robertson, Jarrod C; Alrajhi, Sharifah
2016-01-01
The general surgeon's robotic learning curve may improve if the experience is classified into categories based on the complexity of the procedures in a small community hospital. The intraoperative time should decrease and the incidence of complications should be comparable to conventional laparoscopy. The learning curve of a single robotic general surgeon in a small community hospital using the da Vinci S platform was analyzed. Measured parameters were operative time, console time, conversion rates, complications, surgical site infections (SSIs), surgical site occurrences (SSOs), length of stay, and patient demographics. Between March 2014 and August 2015, 101 robotic general surgery cases were performed by a single surgeon in a 266-bed community hospital, including laparoscopic cholecystectomies, inguinal hernia repairs; ventral, incisional, and umbilical hernia repairs; and colorectal, foregut, bariatric, and miscellaneous procedures. Ninety-nine of the cases were completed robotically. Seven patients were readmitted within 30 days. There were 8 complications (7.92%). There were no mortalities and all complications were resolved with good outcomes. The mean operative time was 233.0 minutes. The mean console operative time was 117.6 minutes. A robotic general surgery program can be safely implemented in a small community hospital with extensive training of the surgical team through basic robotic skills courses as well as supplemental educational experiences. Although the use of the robotic platform in general surgery could be limited to complex procedures such as foregut and colorectal surgery, it can also be safely used in a large variety of operations with results similar to those of conventional laparoscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearce, R.J.H.; Bell, A.C.; Brennan, D.
'Trace Tritium Experiments' (TTE) were successfully performed on JET in 2003. The Campaign marked the first use of tritium in JET plasmas since the Deuterium-Tritium Experiment (DTE1) Campaign in 1997, and was the first use of tritium in experiments under the EFDA organisation with the UKAEA as JET Operator. The safety and regulatory preparations for the experiment were extensive. Since JET has been operated by the UKAEA the operations have followed the model of a licensed nuclear site. The safe operation of the JET torus is demonstrated in a safety case. Key Safety Management Requirement (KSMR) and Key Safety Relatedmore » Equipment (KSRE) are identified in the Safety Case for DT operation. The safe operation of the torus is within the bounds of, and under the control of, an Authority to Operate (ATO). New technical challenges were presented by the need to inject and account for small quantities of tritium in very short pulses ({approx}80ms), with an accurate time stamp. The safety and operational management of the campaign are described. Valuable lessons were learned which would help in running future experiments. It is concluded that JET is in a strong position to run future trace tritium and full DT discharges.« less
NASA Astrophysics Data System (ADS)
Hoson, Takayuki; Akamatsu, Haruhiko; Soga, Kouichi; Wakabayashi, Kazuyuki; Hashimoto, Hirofumi; Yamashita, Masamichi; Hasegawa, Katsuya; Yano, Sachiko; Omori, Katsunori; Ishioka, Noriaki; Matsumoto, Shohei; Kasahara, Haruo; Shimazu, Toru; A. Baba, Shoji; Hashimoto, Takashi
Gravity resistance is a principal graviresponse in plants. In resistance to hypergravity, the gravity signal may be perceived by the mechanoreceptors located on the plasma membrane, and then transformed and transduced via the structural continuum or physiological continuity of cortical microtubules-plasma membrane-cell wall, leading to an increase in the cell wall rigidity as the final response. The Resist Tubule experiment, which will be conducted in the Kibo Module on the International Space Station, aims to confirm that this hypothesis is applicable to resistance to 1 G gravity. There are two major objectives in the Resist Tubule experiment. One is to quantify the contributions of cortical microtubules to gravity resistance using Arabidopsis tubulin mutants with different degrees of defects. Another objective is to analyze the modifications to dynamics of cortical microtubules and membrane rafts under microgravity conditions on-site by observing green fluorescent protein (GFP)-expressing Arabidopsis lines with the fluorescence microscope in the Kibo. We have selected suitable mutants, developed necessary hardware, and fixed operation procedure for the experiment.
The MOMENT to search for CP violation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blennow, Mattias; Coloma, Pilar; Fernández-Martinez, Enrique
In this letter, we analyze for the first time the physics reach in terms of sensitivity to leptonic CP violation of the proposed MuOn-decay MEdium baseline NeuTrino beam (MOMENT) experiment, a novel neutrino oscillation facility that would operate with neutrinos from muon decay. Apart from obtaining a sufficiently intense flux, the bottlenecks to the physics reach of this experiment will be achieving a high enough suppression of the atmospheric background and, particularly, attaining a sufficient level of charge identification. We thus present our results as a function of these two factors. We consider a very massive Gd-doped Water Cherenkov detector.more » We also find that MOMENT will be competitive with other currently planned future oscillation experiments if a charge identification of at least 80 % can be achieved at the same time that the atmospheric background can be suppressed by at least a factor of ten. We also find a large synergy of MOMENT with the current generation of neutrino oscillation experiments, T2K and NOvA, which significantly enhances its final sensitivity.« less
The MOMENT to search for CP violation
Blennow, Mattias; Coloma, Pilar; Fernández-Martinez, Enrique
2016-03-30
In this letter, we analyze for the first time the physics reach in terms of sensitivity to leptonic CP violation of the proposed MuOn-decay MEdium baseline NeuTrino beam (MOMENT) experiment, a novel neutrino oscillation facility that would operate with neutrinos from muon decay. Apart from obtaining a sufficiently intense flux, the bottlenecks to the physics reach of this experiment will be achieving a high enough suppression of the atmospheric background and, particularly, attaining a sufficient level of charge identification. We thus present our results as a function of these two factors. We consider a very massive Gd-doped Water Cherenkov detector.more » We also find that MOMENT will be competitive with other currently planned future oscillation experiments if a charge identification of at least 80 % can be achieved at the same time that the atmospheric background can be suppressed by at least a factor of ten. We also find a large synergy of MOMENT with the current generation of neutrino oscillation experiments, T2K and NOvA, which significantly enhances its final sensitivity.« less
TSTA Piping and Flame Arrestor Operating Experience Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cadwallader, Lee C.; Willms, R. Scott
The Tritium Systems Test Assembly (TSTA) was a facility dedicated to tritium handling technology and experiment research at the Los Alamos National Laboratory. The facility operated from 1984 to 2001, running a prototype fusion fuel processing loop with ~100 grams of tritium as well as small experiments. There have been several operating experience reports written on this facility’s operation and maintenance experience. This paper describes analysis of two additional components from TSTA, small diameter gas piping that handled small amounts of tritium in a nitrogen carrier gas, and the flame arrestor used in this piping system. The operating experiences andmore » the component failure rates for these components are discussed in this paper. Comparison data from other applications are also presented.« less
Mapping the global health employment market: an analysis of global health jobs.
Keralis, Jessica M; Riggin-Pathak, Brianne L; Majeski, Theresa; Pathak, Bogdan A; Foggia, Janine; Cullinen, Kathleen M; Rajagopal, Abbhirami; West, Heidi S
2018-02-27
The number of university global health training programs has grown in recent years. However, there is little research on the needs of the global health profession. We therefore set out to characterize the global health employment market by analyzing global health job vacancies. We collected data from advertised, paid positions posted to web-based job boards, email listservs, and global health organization websites from November 2015 to May 2016. Data on requirements for education, language proficiency, technical expertise, physical location, and experience level were analyzed for all vacancies. Descriptive statistics were calculated for the aforementioned job characteristics. Associations between technical specialty area and requirements for non-English language proficiency and overseas experience were calculated using Chi-square statistics. A qualitative thematic analysis was performed on a subset of vacancies. We analyzed the data from 1007 global health job vacancies from 127 employers. Among private and non-profit sector vacancies, 40% (n = 354) were for technical or subject matter experts, 20% (n = 177) for program directors, and 16% (n = 139) for managers, compared to 9.8% (n = 87) for entry-level and 13.6% (n = 120) for mid-level positions. The most common technical focus area was program or project management, followed by HIV/AIDS and quantitative analysis. Thematic analysis demonstrated a common emphasis on program operations, relations, design and planning, communication, and management. Our analysis shows a demand for candidates with several years of experience with global health programs, particularly program managers/directors and technical experts, with very few entry-level positions accessible to recent graduates of global health training programs. It is unlikely that global health training programs equip graduates to be competitive for the majority of positions that are currently available in this field.
End-To-END Performance of the Future MOMA Instrument Aboard the ExoMars Mission
NASA Astrophysics Data System (ADS)
Pinnick, V. T.; Buch, A.; Szopa, C.; Grand, N.; Danell, R.; Grubisic, A.; van Amerom, F. H. W.; Glavin, D. P.; Freissinet, C.; Coll, P. J.; Stalport, F.; Humeau, O.; Arevalo, R. D., Jr.; Brinckerhoff, W. B.; Steininger, H.; Goesmann, F.; Raulin, F.; Mahaffy, P. R.
2015-12-01
Following the SAM experiment aboard the Curiosity rover, the Mars Organic Molecule Analyzer (MOMA) experiment aboard the 2018 ExoMars mission will be the continuation of the search for organic matter on the Mars surface. One advancement with the ExoMars mission is that the sample will be extracted as deep as 2 meters below the Martian surface to minimize effects of radiation and oxidation on organic materials. To analyze the wide range of organic composition (volatile and non-volatile compounds) of the Martian soil, MOMA is equipped with a dual ion source ion trap mass spectrometer utilizing UV laser desorption / ionization (LDI) and pyrolysis gas chromatography (pyr-GC). In order to analyze refractory organic compounds and chiral molecules during GC-ITMS analysis, samples may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]). Previous experimental reports have focused on coupling campaigns between the breadboard versions of the GC, provided by the French team (LISA, LATMOS, CentraleSupelec), and the MS, provided by the US team (NASA-GSFC). This work focuses on the performance verification and optimization of the GC-ITMS experiment using the Engineering Test Unit (ETU) models which are representative of the form, fit and function of the flight instrument including a flight-like pyrolysis oven and tapping station providing by the German team (MPS). The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation. References: [1] Buch, A. et al. (2009) J Chrom. A, 43, 143-151. [2] Freissinet et al. (2011) J Chrom A, 1306, 59-71. [3] Geffroy-Rodier, C. et al. (2009) JAAP, 85, 454-459.
Selby, Edward A.; Anestis, Michael D.; Bender, Theodore W.; Ribeiro, Jessica D.; Nock, Matthew K.; Rudd, M. David; Bryan, Craig J.; Lim, Ingrid C.; Baker, Monty T.; Gutierrez, Peter M.; Joiner, Thomas E.
2009-01-01
Suicide rates have been increasing in military personnel since the start of Operation Enduring Freedom and Operation Iraqi Freedom, and it is vital that efforts be made to advance suicide risk assessment techniques and treatment for members of the military who may be experiencing suicidal symptoms. One potential way to advance the understanding of suicide in the military is through the use of the Interpersonal-Psychological Theory of Suicide. This theory proposes that three necessary factors are needed to complete suicide: feelings that one does not belong with other people, feelings that one is a burden on others or society, and an acquired capability to overcome the fear and pain associated with suicide. This review analyzes the various ways that military service may influence suicidal behavior and integrates these findings into an overall framework with relevant practical implications. Findings suggest that although there are many important factors in military suicide, the acquired capability may be the most impacted by military experience because combat exposure and training may cause habituation to fear of painful experiences, including suicide. Future research directions, ways to enhance risk assessment, and treatment implications are also discussed. PMID:20051309
NASA Astrophysics Data System (ADS)
Paengchit, Phacharadit; Saikaew, Charnnarong
2018-02-01
This work aims to investigate the effects of feed rate on surface roughness (Ra) and tool wear (VB) and to obtain the optimal operating condition of the feed rate in dry hard turning of AISI 4140 chromium molybdenum steel for automotive industry applications using TiN+AlCrN coated inserts. AISI 4140 steel bars were employed in order to carry out the dry hard turning experiments by varying the feed rates of 0.06, 0.08 and 0.1 mm/rev based on experimental design technique that can be analyzed by analysis of variance (ANOVA). In addition, the cutting tool inserts were examined after machining experiments by SEM to evaluate the effect of turning operations on tool wear. The results showed that averages Ra and VB were significantly affected by the feed rate at the level of significance of 0.05. Averages Ra and VB values at the feed rate of 0.06 mm/rev were lowest compared to average values at the feed rates of 0.08 and 0.1 mm/rev, based on the main effect plot.
Measurements of Plasma Power Losses in the C-2 Field-Reversed Configuration Experiment
NASA Astrophysics Data System (ADS)
Korepanov, Sergey; Smirnov, Artem; Garate, Eusebio; Donin, Alexandr; Kondakov, Alexey; Singatulin, Shavkat
2013-10-01
A high-confinement operating regime with plasma lifetimes significantly exceeding past empirical scaling laws was recently obtained by combining plasma gun edge biasing and tangential Neutral Beam Injection in the C-2 field-reversed configuration (FRC) experiment. To analyze the power balance in C-2, two new diagnostic instruments - the pyroelectric (PE) and infrared (IR) bolometers - were developed. The PE bolometer, designed to operate in the incident power density range from 0.1-100 W/cm2, is used to measure the radial power loss, which is dominated by charge-exchange neutrals and radiation. The IR bolometer, which measures power irradiated onto a thin metal foil inserted in the plasma, is designed for the power density range from 0.5-5 kW/cm2. The IR bolometer is used to measure the axial power loss from the plasma near the end divertors. The maximum measurable pulse duration of ~ 10 ms is limited by the heat capacitance of the IR detector. Both detectors have time resolution of about 10-100 μs and were calibrated in absolute units using a high power neutral beam. We present the results of first direct measurements of axial and radial plasma power losses in C-2.
2009-07-10
CAPE CANAVERAL, Fla. – A lightning strike on Launch Pad 39A at NASA's Kennedy Space Center in Florida is captured by an Operational Television camera. Eleven lightning strikes occurred within .35 miles of the pad during a thunderstorm July 10 as space shuttle Endeavour was prepared for launch. Mission managers decided to delay Endeavour's planned liftoff July 11 as a precaution to allow engineers and safety personnel time to analyze data and retest systems on the orbiter and solid rockets boosters. The next launch attempt for the STS-127 mission is planned for Sunday, July 12, at 7:13 p.m. EDT. The Operational Television cameras can be used to triangulate the location of lightning strikes. Other detection systems include the Cloud-To-Ground Lightning Surveillance System, Strikenet/National Lightning Detection Network, Lightning Induced Voltage Instrumentation System and the Catenary Wire Lightning Instrumentation System. Endeavour will deliver the Japanese Experiment Module's Exposed Facility, or JEM-EF, and the Experiment Logistics Module-Exposed Section, or ELM-ES, in the final of three flights dedicated to the assembly of the Japan Aerospace Exploration Agency's Kibo laboratory complex on the International Space Station. STS-127 is the 29th flight for the assembly of the space station. Photo credit: NASA/Analex
[EXPERIENCE IN THE APPLICATION OF DATABASES ON BLOODSUCKING INSECTS IN ZOOLOGICAL STUDIES].
Medvedev, S G; Khalikov, R G
2016-01-01
The paper summarizes long-term experience of accumulating and summarizing the faunistic information by means of separate databases (DB) and information analytical systems (IAS), and also prospects of its representation by modern multi-user informational systems. The experience obtained during development and practical use of the PARHOST1 IAS for the study of the world flea fauna and work with personal databases created for the study of bloodsucking insects (lice and blackflies) is analyzed. Research collection material on type series of 57 species and subspecies of fleas of the fauna of Russia was approved as a part of multi-user information retrieval system on the web-portal of the Zoological Institute of the Russian Academy of Sciences. According former investigations, the system allows depositing the information in the authentic form and performing its gradual transformation, i. e. its unification and structuring. In order to provide continuity of DB refill, the possibility of work of operators with different degree of competence is provided.
Physics evaluation of compact tokamak ignition experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uckan, N.A.; Houlberg, W.A.; Sheffield, J.
1985-01-01
At present, several approaches for compact, high-field tokamak ignition experiments are being considered. A comprehensive method for analyzing the potential physics operating regimes and plasma performance characteristics of such ignition experiments with O-D (analytic) and 1-1/2-D (WHIST) transport models is presented. The results from both calculations are in agreement and show that there are regimes in parameter space in which a class of small (R/sub o/ approx. 1-2 m), high-field (B/sub o/ approx. 8-13 T) tokamaks with aB/sub o/S/q/sub */ approx. 25 +- 5 and kappa = b/a approx. 1.6-2.0 appears ignitable for a reasonable range of transport assumptions. Consideringmore » both the density and beta limits, an evaluation of the performance is presented for various forms of chi/sub e/ and chi/sub i/, including degradation at high power and sawtooth activity. The prospects of ohmic ignition are also examined. 16 refs., 13 figs.« less
Satisfaction and gender issues in otolaryngology residency.
Wynn, Rhoda; Rosenfeld, Richard M; Lucente, Frank E
2005-06-01
To evaluate the otolaryngology residency experience with attention to operative experience, career guidance, and gender. Otolaryngology residents were anonymously surveyed by mail about their residency experience. The 22-item survey was scored on a 5-point ordinal Likert scale. Responses were analyzed with respect to gender and postgraduate year (PGY) level. Complete surveys were returned by 261 otolaryngology residents (24% female). PGY level correlated with confidence that surgical skills were appropriate (P = 0.003), establishment of solid career network (P = 0.003), and confidence that surgical abilities are adequate for practice (P = 0.028). Female residents reported less confidence that surgical skills were appropriate (P = 0.050) and that surgical abilities were adequate for postresidency practice (P = 0.035). Women were encouraged to enter private practice more often (P = 0.012), were less likely to have a solid career network ( P = 0.025), and were less confident about being able to run their own practice (P = 0.036) Significant differences exist for several questions regarding surgical confidence and career issues, even after correction for PGY level.
Support activities to maintain SUMS flight readiness, volume 2. Attachment A: Flight 61-C report
NASA Technical Reports Server (NTRS)
Wright, Willie
1992-01-01
The Shuttle Upper Atmosphere Mass Spectrometer (SUMS), a component experiment of the NASA Orbital Experiments Program (OEX), was flown aboard the shuttle Columbia (OV102) mounted at the forward end of the nose landing gear well with an atmospheric gas inlet system fitted to the lower fuselage (chin panel) surface. The SUMS was designed to provide atmospheric data in flow regimes inaccessible prior to the development of the Space Transportation system (STS). The experiment mission operation begins about 1 hour to shuttle de-orbit entry maneuver and continues until reaching 1.6 torr (about 86 km altitude). The SUMS flew a total of three missions, 61C, STS-35, and STS-40. Between flights, the SUMS was maintained in flight ready status. The flight data has been analyzed by the NASA LaRC Aerothermodynamics Branch. Flight data spectrum plots and reports are presented in the Appendices to the Final Technical Report for NAS1-17399. This volume is the flight data report for flight 61-C.
Ankowski, Artur M.; Benhar, Omar; Coloma, Pilar; ...
2015-10-22
To be able to achieve their physics goals, future neutrino-oscillation experiments will need to reconstruct the neutrino energy with very high accuracy. In this work, we analyze how the energy reconstruction may be affected by realistic detection capabilities, such as energy resolutions, efficiencies, and thresholds. This allows us to estimate how well the detector performance needs to be determined a priori in order to avoid a sizable bias in the measurement of the relevant oscillation parameters. We compare the kinematic and calorimetric methods of energy reconstruction in the context of two ν μ → ν μ disappearance experiments operating inmore » different energy regimes. For the calorimetric reconstruction method, we find that the detector performance has to be estimated with an O(10%) accuracy to avoid a significant bias in the extracted oscillation parameters. Thus, in the case of kinematic energy reconstruction, we observe that the results exhibit less sensitivity to an overestimation of the detector capabilities.« less
An OS9-UNIX data acquisition system with ECL readout
NASA Astrophysics Data System (ADS)
Ziem, P.; Beschorner, C.; Bohne, W.; Drescher, B.; Friese, T.; Kiehne, T.; Kluge, Ch.
1996-02-01
A new data acquisition system has been developed at the Hahn-Meitner-Institut to handle almost 550 parameters of nuclear physics experiments. The system combines a UNIX host running a portable data buffer router and a VME front-end based on the OS9 real time operating system. Different kinds of pulse analyzers are located in several CAMAC crates which are controlled by the VME system via a VICbus connection. Data readout is performed by means of an ECL daisy chain. Besides controlling CAMAC the main purpose of the VME front-end is event data formatting and histogramming. Using TCP/IP services, the UNIX host receives formatted data packages for data storage and display. During a beam time at the antiproton accelerator LEAR/CERN, the PS208 experiment has accumulated about 100 Gbyte of event data [2
An OS9-UNIX data acquisition system with ECL readout
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziem, P.; Beschorner, C.; Bohne, W.
1996-02-01
A new data acquisition system has been developed at the Hahn-Meitner-Institut to handle almost 550 parameters of nuclear physics experiments. The system combines a UNIX host running a portable data buffer router and a VME front-end based on the OS9 real time operating system. Different kinds of pulse analyzers are located in several CAMAC crates which are controlled by the VME system via a VICbus connection. Data readout is performed by means of an ECL daisy chain. Besides controlling CAMAC the main purpose of the VME front-end is event data formatting and histogramming. Using TCP/IP services, the UNIX host receivesmore » formatted data packages for data storage and display. During a beam time at the antiproton accelerator LEAR/CERN, the PS208 experiment has accumulated about 100 Gbyte of event data.« less
NASA Astrophysics Data System (ADS)
Abbasi, R. U.; Abe, M.; Abu-Zayyad, T.; Allen, M.; Azuma, R.; Barcikowski, E.; Belz, J. W.; Bergman, D. R.; Blake, S. A.; Cady, R.; Cheon, B. G.; Chiba, J.; Chikawa, M.; Cho, W. R.; Fujii, T.; Fukushima, M.; Goto, T.; Hanlon, W.; Hayashi, Y.; Hayashida, N.; Hibino, K.; Honda, K.; Ikeda, D.; Inoue, N.; Ishii, T.; Ishimori, R.; Ito, H.; Ivanov, D.; Jui, C. C. H.; Kadota, K.; Kakimoto, F.; Kalashev, O.; Kasahara, K.; Kawai, H.; Kawakami, S.; Kawana, S.; Kawata, K.; Kido, E.; Kim, H. B.; Kim, J. H.; Kim, J. H.; Kitamura, S.; Kitamura, Y.; Kuzmin, V.; Kwon, Y. J.; Lan, J.; Lundquist, J. P.; Machida, K.; Martens, K.; Matsuda, T.; Matsuyama, T.; Matthews, J. N.; Minamino, M.; Mukai, Y.; Myers, I.; Nagasawa, K.; Nagataki, S.; Nakamura, T.; Nonaka, T.; Nozato, A.; Ogio, S.; Ogura, J.; Ohnishi, M.; Ohoka, H.; Oki, K.; Okuda, T.; Ono, M.; Oshima, A.; Ozawa, S.; Park, I. H.; Pshirkov, M. S.; Rodriguez, D. C.; Rubtsov, G.; Ryu, D.; Sagawa, H.; Sakurai, N.; Scott, L. M.; Shah, P. D.; Shibata, F.; Shibata, T.; Shimodaira, H.; Shin, B. K.; Shin, H. S.; Smith, J. D.; Sokolsky, P.; Springer, R. W.; Stokes, B. T.; Stratton, S. R.; Stroman, T. A.; Suzawa, T.; Takamura, M.; Takeda, M.; Takeishi, R.; Taketa, A.; Takita, M.; Tameda, Y.; Tanaka, H.; Tanaka, K.; Tanaka, M.; Thomas, S. B.; Thomson, G. B.; Tinyakov, P.; Tkachev, I.; Tokuno, H.; Tomida, T.; Troitsky, S.; Tsunesada, Y.; Tsutsumi, K.; Uchihori, Y.; Udo, S.; Urban, F.; Vasiloff, G.; Wong, T.; Yamane, R.; Yamaoka, H.; Yamazaki, K.; Yang, J.; Yashiro, K.; Yoneda, Y.; Yoshida, S.; Yoshii, H.; Zollinger, R.; Zundel, Z.
2016-07-01
The Telescope Array (TA) experiment is the largest detector to observe ultra-high-energy cosmic rays in the northern hemisphere. The fluorescence detectors at two stations of TA are newly constructed and have now completed seven years of steady operation. One advantage of monocular analysis of the fluorescence detectors is a lower energy threshold for cosmic rays than that of other techniques like stereoscopic observations or coincidences with the surface detector array, allowing the measurement of an energy spectrum covering three orders of magnitude in energy. Analyzing data collected during those seven years, we report the energy spectrum of cosmic rays covering a broad range of energies above 1017.2eV measured by the fluorescence detectors and a comparison with previously published results.
Lee, Hangyeore; Mun, Dong-Gi; Bae, Jingi; Kim, Hokeun; Oh, Se Yeon; Park, Young Soo; Lee, Jae-Hyuk; Lee, Sang-Won
2015-08-21
We report a new and simple design of a fully automated dual-online ultra-high pressure liquid chromatography system. The system employs only two nano-volume switching valves (a two-position four port valve and a two-position ten port valve) that direct solvent flows from two binary nano-pumps for parallel operation of two analytical columns and two solid phase extraction (SPE) columns. Despite the simple design, the sDO-UHPLC offers many advantageous features that include high duty cycle, back flushing sample injection for fast and narrow zone sample injection, online desalting, high separation resolution and high intra/inter-column reproducibility. This system was applied to analyze proteome samples not only in high throughput deep proteome profiling experiments but also in high throughput MRM experiments.
Hauksson, Egill; Goebel, Thomas; Ampuero, Jean-Paul; Cochran, Elizabeth S.
2015-01-01
Most of the seismicity in the Los Angeles Basin (LA Basin) occurs at depth below the sediments and is caused by transpressional tectonics related to the big bend in the San Andreas fault. However, some of the seismicity could be associated with fluid extraction or injection in oil fields that have been in production for almost a century and cover ∼ 17% of the basin. In a recent study, first the influence of industry operations was evaluated by analyzing seismicity characteristics, including normalized seismicity rates, focal depths, and b-values, but no significant difference was found in seismicity characteristics inside and outside the oil fields. In addition, to identify possible temporal correlations, the seismicity and available monthly fluid extraction and injection volumes since 1977 were analyzed. Second, the production and deformation history of the Wilmington oil field were used to evaluate whether other oil fields are likely to experience similar surface deformation in the future. Third, the maximum earthquake magnitudes of events within the perimeters of the oil fields were analyzed to see whether they correlate with total net injected volumes, as suggested by previous studies. Similarly, maximum magnitudes were examined to see whether they exhibit an increase with net extraction volume. Overall, no obvious previously unidentified induced earthquakes were found, and the management of balanced production and injection of fluids appears to reduce the risk of induced-earthquake activity in the oil fields.
Relationship between Recent Flight Experience and Pilot Error General Aviation Accidents
NASA Astrophysics Data System (ADS)
Nilsson, Sarah J.
Aviation insurance agents and fixed-base operation (FBO) owners use recent flight experience, as implied by the 90-day rule, to measure pilot proficiency in physical airplane skills, and to assess the likelihood of a pilot error accident. The generally accepted premise is that more experience in a recent timeframe predicts less of a propensity for an accident, all other factors excluded. Some of these aviation industry stakeholders measure pilot proficiency solely by using time flown within the past 90, 60, or even 30 days, not accounting for extensive research showing aeronautical decision-making and situational awareness training decrease the likelihood of a pilot error accident. In an effort to reduce the pilot error accident rate, the Federal Aviation Administration (FAA) has seen the need to shift pilot training emphasis from proficiency in physical airplane skills to aeronautical decision-making and situational awareness skills. However, current pilot training standards still focus more on the former than on the latter. The relationship between pilot error accidents and recent flight experience implied by the FAA's 90-day rule has not been rigorously assessed using empirical data. The intent of this research was to relate recent flight experience, in terms of time flown in the past 90 days, to pilot error accidents. A quantitative ex post facto approach, focusing on private pilots of single-engine general aviation (GA) fixed-wing aircraft, was used to analyze National Transportation Safety Board (NTSB) accident investigation archival data. The data were analyzed using t-tests and binary logistic regression. T-tests between the mean number of hours of recent flight experience of tricycle gear pilots involved in pilot error accidents (TPE) and non-pilot error accidents (TNPE), t(202) = -.200, p = .842, and conventional gear pilots involved in pilot error accidents (CPE) and non-pilot error accidents (CNPE), t(111) = -.271, p = .787, indicate there is no statistically significant relationship between groups. Binary logistic regression indicate that recent flight experience does not reliably distinguish between pilot error and non-pilot error accidents for TPE/TNPE, chi2 = 0.040 (df=1, p = .841) and CPE/CNPE, chi2= 0.074 (df =1, p = .786). Future research could focus on different pilot populations, and to broaden the scope, analyze several years of data.
Experimental and numerical investigation of a scalable modular geothermal heat storage system
NASA Astrophysics Data System (ADS)
Nordbeck, Johannes; Bauer, Sebastian; Beyer, Christof
2017-04-01
Storage of heat will play a significant role in the transition towards a reliable and renewable power supply, as it offers a way to store energy from fluctuating and weather dependent energy sources like solar or wind power and thus better meet consumer demands. The focus of this study is the simulation-based design of a heat storage system, featuring a scalable and modular setup that can be integrated with new as well as existing buildings. For this, the system can be either installed in a cellar or directly in the ground. Heat supply is by solar collectors, and heat storage is intended at temperatures up to about 90°C, which requires a verification of the methods used for numerical simulation of such systems. One module of the heat storage system consists of a helical heat exchanger in a fully water saturated, high porosity cement matrix, which represents the heat storage medium. A lab-scale storage prototype of 1 m3 volume was set up in a thermally insulated cylinder equipped with temperature and moisture sensors as well as flux meters and temperature sensors at the inlet and outlet pipes in order to experimentally analyze the performance of the storage system. Furthermore, the experimental data was used to validate an accurate and spatially detailed high-resolution 3D numerical model of heat and fluid flow, which was developed for system design optimization with respect to storage efficiency and environmental impacts. Three experiments conducted so far are reported and analyzed in this work. The first experiment, consisting of cooling of the fully loaded heat storage by heat loss across the insulation, is designed to determine the heat loss and the insulation parameters, i.e. heat conductivity and heat capacity of the insulation, via inverse modelling of the cooling period. The average cooling rate experimentally found is 1.2 °C per day. The second experiment consisted of six days of thermal loading up to a storage temperature of 60°C followed by four days of heat extraction. The experiment was performed for the determination of heat losses during a complete thermal loading and extraction cycle. The storage could be charged with 54 kWh of heat energy during thermal loading. 36 kWh could be regained during the extraction period, which translates to a heat loss of 33% during the 10 days of operation. Heat exchanger fluid flow rates and supply temperature were measured during the experiment and used as input for the 3D finite element model. Numerically simulated temperature distribution in the storage, return temperature and heat balances were compared to the measured data and showed that the 3D model accurately reflects the storage behavior. Also the third experiment, consisting of six days of cyclic operation after five days of continuous thermal loading, a good agreement between observed and modelled heat storage behavior is found. In addition to determining the storage performance during cyclic operation, the experiment will also be used to further validate the numerical model. This abstract will present the laboratory setup as well as the experimental data obtained from the experiment. It will also present the modelling approach chosen for the numerical representation of the experiment and give a comparison between measured and modelled temperatures and heat balances for the modular heat storage system.
Experiment module concepts study. Volume 2: Experiments and mission operations
NASA Technical Reports Server (NTRS)
Macdonald, J. M.
1970-01-01
The baseline experiment program is concerned with future space experiments and cover the scientific disciplines of astronomy, space physics, space biology, biomedicine and biotechnology, earth applications, materials science, and advanced technology. The experiments within each discipline are grouped into functional program elements according to experiments that support a particular area of research or investigation and experiments that impose similar or related demand on space station support systems. The experiment requirements on module subsystems, experiment operating modes and time profiles, and the role of the astronaut are discussed. Launch and rendezvous with the space station, disposal, and on-orbit operations are delineated. The operational interfaces between module and other system elements are presented and include space station and logistic system interfaces. Preliminary launch and on-orbit environmental criteria and requirements are discussed, and experiment equipment weights by functional program elements are tabulated.
The Pacor 2 expert system: A case-based reasoning approach to troubleshooting
NASA Technical Reports Server (NTRS)
Sary, Charisse
1994-01-01
The Packet Processor 2 (Pacor 2) Data Capture Facility (DCF) acquires, captures, and performs level-zero processing of packet telemetry for spaceflight missions that adhere to communication services recommendations established by the Consultative Committee for Space Data Systems (CCSDS). A major goal of this project is to reduce life-cycle costs. One way to achieve this goal is to increase automation. Through automation, using expert systems, and other technologies, staffing requirements will remain static, which will enable the same number of analysts to support more missions. Analysts provide packet telemetry data evaluation and analysis services for all data received. Data that passes this evaluation is forwarded to the Data Distribution Facility (DDF) and released to scientists. Through troubleshooting, data that fails this evaluation is dumped and analyzed to determine if its quality can be improved before it is released. This paper describes a proof-of-concept prototype that troubleshoots data quality problems. The Pacor 2 expert system prototype uses the case-based reasoning (CBR) approach to development, an alternative to a rule-based approach. Because Pacor 2 is not operational, the prototype has been developed using cases that describe existing troubleshooting experience from currently operating missions. Through CBR, this experience will be available to analysts when Pacor 2 becomes operational. As Pacor 2 unique experience is gained, analysts will update the case base. In essence, analysts are training the system as they learn. Once the system has learned the cases most likely to recur, it can serve as an aide to inexperienced analysts, a refresher to experienced analysts for infrequently occurring problems, or a training tool for new analysts. The Expert System Development Methodology (ESDM) is being used to guide development.
Social Media and Pediatric Scoliosis: An Analysis of Patient and Surgeon Use.
Haeberle, Heather S; Egger, Anthony C; Navarro, Sergio M; Cornaghie, Mary M; Ramkumar, Prem N; Goodwin, Ryan C; Mont, Michael A
2017-10-12
The purpose of this observational study was to investigate and analyze the social media presence of both patients and surgeons in relation to pediatric scoliosis. First, patient Instagram (Instagram, Inc., San Francisco, California) posts were evaluated for 1) media format; 2) timing in relation to surgery; 3) tone; 4) perspective; 5) content; and 6) subject reference. To analyze reciprocal engagement, the presence and activity of pediatric scoliosis surgeons at five major academic centers were subsequently analyzed on Instagram, Twitter (Twitter Inc., San Francisco, California), and LinkedIn (LinkedIn Corporation, Sunnyvale, California). A search of public Instagram profiles was performed over a one-year period from February 2016 to February 2017. Posts related to pediatric scoliosis were selected for analysis using a hashtag search with 30 related terms. A total of 982 posts were retrieved, with 669 posts meeting the inclusion criteria. Each post was then evaluated for timing, tone, perspective, and content using a categorical scoring system. An additional analysis was performed using academic orthopaedic hospitals' websites, in which the names of scoliosis surgeons were found and searched for on Instagram, Twitter, and LinkedIn. Their profiles were analyzed for level and length of activity, number of followers or connections, and references to clinical practice. A total of 669 posts related to scoliosis were analyzed, the majority of which were temporally related to non-operative (74.7%) or post-operative (21.8%) settings. Patients (33.3%), friends and family (34.4%), and professional organizations (23.8%) were the most active contributors. The vast majority of posts were positive in nature (88.9 %) and highlighted the patient experience (79.2%), specifically related to bracing (33.1%), activities of daily living (31.7%), and surgical site or x-rays (25.5%). Of the social media sites analyzed, surgeons were found to have the highest presence on LinkedIn (55% have accounts with a mean of 175 connections) compared to Instagram (8%, 57 followers) and Twitter (33%, 61 followers). Surgeons were also noted to have more information regarding their practice, training, and clinical skills on LinkedIn. An analysis of Instagram posts related to scoliosis showed that the majority were shared by patients in the non-operative period and overwhelmingly had a positive tone. The content of the posts focused mainly on brace wear, activities of daily living, and post-operative appearance or x-rays. This information provides further insight into what patients deem important regarding pediatric scoliosis care. Analysis of the social media presence of scoliosis surgeons showed that they have an underwhelming presence on Instagram and Twitter, but are more active on LinkedIn, a site geared more toward professional development and networking than other social media options.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medley, S.S.
The application of charge exchange analyzers for the measurement of ion temperature in fusion plasma experiments requires a direct connection between the diagnostic and plasma-discharge vacuum chambers. Differential pumping of the gas load from the diagnostic stripping cell operated at > or approx. = 10/sup -3/ Torr is required to maintain the analyzer chamber at a pressure of < or approx. = 10/sup -6/ Torr. The migration of gases between the diagnostic and plasma vacuum chambers must be minimized. In particular, introduction of the analyzer stripping cell gas into the plasma chamber having a base pressure of < or approx.more » = 10/sup -8/ Torr must be suppressed. The charge exchange diagnostic for the Tokamak Fusion Test Reactor (TFTR) is comprised of two analyzer systems designed to contain a total of 18 independent mass/energy analyzers and one diagnostic neutral beam rated at 80 keV, 15 A. The associated arrays of multiple, interconnected vacuum systems were analyzed using the Vacuum System Transient Simulator (Vsts) computer program which models the transient transport of multigas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced costs, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and of the diagnostic working gases to the torus.« less
Objective assessment of operator performance during ultrasound-guided procedures.
Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R
2011-09-01
Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.
Safety Verification of the Small Aircraft Transportation System Concept of Operations
NASA Technical Reports Server (NTRS)
Carreno, Victor; Munoz, Cesar
2005-01-01
A critical factor in the adoption of any new aeronautical technology or concept of operation is safety. Traditionally, safety is accomplished through a rigorous process that involves human factors, low and high fidelity simulations, and flight experiments. As this process is usually performed on final products or functional prototypes, concept modifications resulting from this process are very expensive to implement. This paper describe an approach to system safety that can take place at early stages of a concept design. It is based on a set of mathematical techniques and tools known as formal methods. In contrast to testing and simulation, formal methods provide the capability of exhaustive state exploration analysis. We present the safety analysis and verification performed for the Small Aircraft Transportation System (SATS) Concept of Operations (ConOps). The concept of operations is modeled using discrete and hybrid mathematical models. These models are then analyzed using formal methods. The objective of the analysis is to show, in a mathematical framework, that the concept of operation complies with a set of safety requirements. It is also shown that the ConOps has some desirable characteristic such as liveness and absence of dead-lock. The analysis and verification is performed in the Prototype Verification System (PVS), which is a computer based specification language and a theorem proving assistant.
Statistics of vacuum breakdown in the high-gradient and low-rate regime
NASA Astrophysics Data System (ADS)
Wuensch, Walter; Degiovanni, Alberto; Calatroni, Sergio; Korsbäck, Anders; Djurabekova, Flyura; Rajamäki, Robin; Giner-Navarro, Jorge
2017-01-01
In an increasing number of high-gradient linear accelerator applications, accelerating structures must operate with both high surface electric fields and low breakdown rates. Understanding the statistical properties of breakdown occurrence in such a regime is of practical importance for optimizing accelerator conditioning and operation algorithms, as well as of interest for efforts to understand the physical processes which underlie the breakdown phenomenon. Experimental data of breakdown has been collected in two distinct high-gradient experimental set-ups: A prototype linear accelerating structure operated in the Compact Linear Collider Xbox 12 GHz test stands, and a parallel plate electrode system operated with pulsed DC in the kV range. Collected data is presented, analyzed and compared. The two systems show similar, distinctive, two-part distributions of number of pulses between breakdowns, with each part corresponding to a specific, constant event rate. The correlation between distance and number of pulses between breakdown indicates that the two parts of the distribution, and their corresponding event rates, represent independent primary and induced follow-up breakdowns. The similarity of results from pulsed DC to 12 GHz rf indicates a similar vacuum arc triggering mechanism over the range of conditions covered by the experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maimone, F., E-mail: f.maimone@gsi.de; Tinschert, K.; Endermann, M.
In order to increase the intensity of the highly charged ions produced by the Electron Cyclotron Resonance Ion Sources (ECRISs), techniques like the frequency tuning and the afterglow mode have been developed and in this paper the effect on the ion production is shown for the first time when combining both techniques. Recent experimental results proved that the tuning of the operating frequency of the ECRIS is a promising technique to achieve higher ion currents of higher charge states. On the other hand, it is well known that the afterglow mode of the ECRIS operation can provide more intense pulsedmore » ion beams in comparison with the continuous wave (cw) operation. These two techniques can be combined by pulsing the variable frequency signal driving the traveling wave tube amplifier which provides the high microwave power to the ECRIS. In order to analyze the effect of these two combined techniques on the ion source performance, several experiments were carried out on the pulsed frequency tuned CAPRICE (Compacte source A Plusiers Résonances Ionisantes Cyclotron Electroniques)-type ECRIS. Different waveforms and pulse lengths have been investigated under different settings of the ion source. The results of the pulsed mode have been compared with those of cw operation.« less
NASA Astrophysics Data System (ADS)
Jing, Wenjun; Zhao, Yan
2018-02-01
Stability is an important part of geotechnical engineering research. The operating experiences of underground storage caverns in salt rock all around the world show that the stability of the caverns is the key problem of safe operation. Currently, the combination of theoretical analysis and numerical simulation are the mainly adopts method of reserve stability analysis. This paper introduces the concept of risk into the stability analysis of underground geotechnical structure, and studies the instability of underground storage cavern in salt rock from the perspective of risk analysis. Firstly, the definition and classification of cavern instability risk is proposed, and the damage mechanism is analyzed from the mechanical angle. Then the main stability evaluating indicators of cavern instability risk are proposed, and an evaluation method of cavern instability risk is put forward. Finally, the established cavern instability risk assessment system is applied to the analysis and prediction of cavern instability risk after 30 years of operation in a proposed storage cavern group in the Huai’an salt mine. This research can provide a useful theoretical base for the safe operation and management of underground storage caverns in salt rock.
Gnuastro: GNU Astronomy Utilities
NASA Astrophysics Data System (ADS)
Akhlaghi, Mohammad
2018-01-01
Gnuastro (GNU Astronomy Utilities) manipulates and analyzes astronomical data. It is an official GNU package of a large collection of programs and C/C++ library functions. Command-line programs perform arithmetic operations on images, convert FITS images to common types like JPG or PDF, convolve an image with a given kernel or matching of kernels, perform cosmological calculations, crop parts of large images (possibly in multiple files), manipulate FITS extensions and keywords, and perform statistical operations. In addition, it contains programs to make catalogs from detection maps, add noise, make mock profiles with a variety of radial functions using monte-carlo integration for their centers, match catalogs, and detect objects in an image among many other operations. The command-line programs share the same basic command-line user interface for the comfort of both the users and developers. Gnuastro is written to comply fully with the GNU coding standards and integrates well with all Unix-like operating systems. This enables astronomers to expect a fully familiar experience in the source code, building, installing and command-line user interaction that they have seen in all the other GNU software that they use. Gnuastro's extensive library is included for users who want to build their own unique programs.
Variable recruitment fluidic artificial muscles: modeling and experiments
NASA Astrophysics Data System (ADS)
Bryant, Matthew; Meller, Michael A.; Garcia, Ephrahim
2014-07-01
We investigate taking advantage of the lightweight, compliant nature of fluidic artificial muscles to create variable recruitment actuators in the form of artificial muscle bundles. Several actuator elements at different diameter scales are packaged to act as a single actuator device. The actuator elements of the bundle can be connected to the fluidic control circuit so that different groups of actuator elements, much like individual muscle fibers, can be activated independently depending on the required force output and motion. This novel actuation concept allows us to save energy by effectively impedance matching the active size of the actuators on the fly based on the instantaneous required load. This design also allows a single bundled actuator to operate in substantially different force regimes, which could be valuable for robots that need to perform a wide variety of tasks and interact safely with humans. This paper proposes, models and analyzes the actuation efficiency of this actuator concept. The analysis shows that variable recruitment operation can create an actuator that reduces throttling valve losses to operate more efficiently over a broader range of its force-strain operating space. We also present preliminary results of the design, fabrication and experimental characterization of three such bioinspired variable recruitment actuator prototypes.
Analysis of the charging of the SCATHA (P78-2) satellite
NASA Technical Reports Server (NTRS)
Stannard, P. R.; Katz, I.; Mandell, M. J.; Cassidy, J. J.; Parks, D. E.; Rotenberg, M.; Steen, P. G.
1980-01-01
The charging of a large object in polar Earth orbit was investigated in order to obtain a preliminary indication of the response of the shuttle orbiter to such an environment. Two NASCAP (NASA Charging Analyzer Program) models of SCATHA (Satellite Charging at High Altitudes) were used in simulations of charging events. The properties of the satellite's constituent materials were compiled and representations of the experimentally observed plasma spectra were constructed. Actual charging events, as well as those using test environments, were simulated. Numerical models for the simulation of particle emitters and detectors were used to analyze the operation of these devices onboard SCATHA. The effect of highly charged surface regions on the charging conductivity within a photosheath was used to interpret results from the onboard electric field experiment. Shadowing calculations were carried out for the satellite and a table of effective illuminated areas was compiled.
Study on Mine Emergency Mechanism based on TARP and ICS
NASA Astrophysics Data System (ADS)
Xi, Jian; Wu, Zongzhi
2018-01-01
By analyzing the experiences and practices of mine emergency in China and abroad, especially the United States and Australia, normative principle, risk management principle and adaptability principle of constructing mine emergency mechanism based on Trigger Action Response Plans (TARP) and Incident Command System (ICS) are summarized. Classification method, framework, flow and subject of TARP and ICS which are suitable for the actual situation of domestic mine emergency are proposed. The system dynamics model of TARP and ICS is established. The parameters such as evacuation ratio, response rate, per capita emergency capability and entry rate of rescuers are set up. By simulating the operation process of TARP and ICS, the impact of these parameters on the emergency process are analyzed, which could provide a reference and basis for building emergency capacity, formulating emergency plans and setting up action plans in the emergency process.
The critical pressure drop for the purge process in the anode of a fuel cell
NASA Astrophysics Data System (ADS)
Yu, Xiao; Pingwen, Ming; Ming, Hou; Baolian, Yi; Shao, Zhi-Gang
Purge operation is an effective way to remove the accumulated liquid water in the anode of proton exchange membrane fuel cells (PEMFCs). This paper studies the phenomenon of the two-phase flow as well as the pressure drop fluctuation inside the flow field of a single cell during the purge process. The flow patterns are identified as intermittent purge and annular purge, and the two purge processes are contrastively analyzed and discussed. The intermittent purge greatly affects the fuel cell performance and thus it is not suitable for the in situ application. The annular purge process requires a higher pressure drop, and the critical pressure drop is calculated from the annular purge model. Furthermore, this value is quantitatively analyzed and validated by experiments. The results show that the annular purge is appropriate for removing liquid water out of the anode in the fuel cell.
NASA Astrophysics Data System (ADS)
Kim, Kwangmin; Go, Byeong-Soo; Sung, Hae-Jin; Park, Hea-chul; Kim, Seokho; Lee, Sangjin; Jin, Yoon-Su; Oh, Yunsang; Park, Minwon; Yu, In-Keun
2014-09-01
This paper describes the design specifications and performance of a real toroid-type high temperature superconducting (HTS) DC reactor. The HTS DC reactor was designed using 2G HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The target inductance of the HTS DC reactor was 400 mH. The expected operating temperature was under 20 K. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. Performances of the toroid-type HTS DC reactor were analyzed through experiments conducted under the steady-state and charge conditions. The fundamental design specifications and the data obtained from this research will be applied to the design of a commercial-type HTS DC reactor.
Knapik, Joseph; Steelman, Ryan
2016-11-01
To identify and analyze articles in which the authors examined risk factors for soldiers during military static-line airborne operations. We searched for articles in PubMed, the Defense Technical Information Center, reference lists, and other sources using the key words airborne, parachuting, parachutes, paratrooper, injuries, wounds, trauma, and musculoskeletal. The search identified 17 684 potential studies. Studies were included if they were written in English, involved military static-line parachute operations, recorded injuries directly from events on the landing zone or from safety or medical records, and provided data for quantitative assessment of injury risk factors. A total of 23 studies met the review criteria, and 15 were included in the meta-analysis. The summary statistic obtained for each risk factor was the risk ratio, which was the ratio of the injury risk in 1 group to that of another (baseline) group. Where data were sufficient, meta-analyses were performed and heterogeneity and publication bias were assessed. Risk factors for static-line parachuting injuries included night jumps, jumps with extra equipment, higher wind speeds, higher air temperatures, jumps from fixed-wing aircraft rather than balloons or helicopters, jumps onto certain types of terrain, being a female paratrooper, greater body weight, not using the parachute ankle brace, smaller parachute canopies, simultaneous exits from both sides of an aircraft, higher heat index, winds from the rear of the aircraft on exit entanglements, less experience with a particular parachute system, being an enlisted soldier rather than an officer, and jumps involving a greater number of paratroopers. We analyzed and summarized factors that increased the injury risk for soldiers during military static-line parachute operations. Understanding and considering these factors in risk evaluations may reduce the likelihood of injury during parachuting.
Eseonu, Chikezie I; ReFaey, Karim; Pamias-Portalatin, Eva; Asensio, Javier; Garcia, Oscar; Boahene, Kofi D; Quiñones-Hinojosa, Alfredo
2018-02-01
Variations on the endoscopic transsphenoidal approach present unique surgical techniques that have unique effects on surgical outcomes, extent of resection (EOR), and anatomical complications. To analyze the learning curve and perioperative outcomes of the 3-hand endoscopic endonasal mononostril transsphenoidal technique. Prospective case series and retrospective data analysis of patients who were treated with the 3-hand transsphenoidal technique between January 2007 and May 2015 by a single neurosurgeon. Patient characteristics, preoperative presentation, tumor characteristics, operative times, learning curve, and postoperative outcomes were analyzed. Volumetric EOR was evaluated, and a logistic regression analysis was used to assess predictors of EOR. Two hundred seventy-five patients underwent an endoscopic transsphenoidal surgery using the 3-hand technique. One hundred eighteen patients in the early group had surgery between 2007 and 2010, while 157 patients in the late group had surgery between 2011 and 2015. Operative time was significantly shorter in the late group (161.6 min) compared to the early group (211.3 min, P = .001). Both cohorts had similar EOR (early group 84.6% vs late group 85.5%, P = .846) and postoperative outcomes. The learning curve showed that it took 54 cases to achieve operative proficiency with the 3-handed technique. Multivariate modeling suggested that prior resections and preoperative tumor size are important predictors for EOR. We describe a 3-hand, mononostril endoscopic transsphenoidal technique performed by a single neurosurgeon that has minimal anatomic distortion and postoperative complications. During the learning curve of this technique, operative time can significantly decrease, while EOR, postoperative outcomes, and complications are not jeopardized. Copyright © 2017 by the Congress of Neurological Surgeons
Influence of torque control motors and the operator's proficiency on ProTaper failures.
Yared, Ghassan; Bou Dagher, Fadia; Kulkarni, Kiran
2003-08-01
The purpose of this study was to evaluate the influence of 2 electric torque control motors and operator experience with a specific nickel-titanium rotary instrumentation technique on the incidence of deformation and separation of instruments. ProTaper (PT) nickel-titanium rotary instruments were used at 300 rpm. In the first part of the study, electric high torque control (group 1) and low torque control (group 2) motors were compared. In the second part of the study, 3 operators with varying experience (groups 3, 4, and 5) were also compared. Twenty sets of PT instruments and 100 canals of extracted human molars were used in each group. Each set of PT instruments was used in up to 5 canals and sterilized before each case. For irrigation, 2.5% NaOCl was used. The number of deformed and separated instruments among the groups (within each part of the study) was statistically analyzed for significance with pair-wise comparisons by using the Fisher exact test (alpha =.05). In part 1, instrument deformation and separation did not occur in groups 1 and 2. In part 2, 25 and 12 instruments were deformed and separated, respectively, with the least experienced operator. Instrument deformation and separation did not occur with the most experienced operator. The Fisher exact test revealed a significant difference between groups 3 and 4 with respect to instrument deformation (P =.0296). In addition, the Fisher exact test revealed that the incidence of instrument deformation was statistically different between groups 3 and 5 (P <.0001) and groups 4 and 5 (P =.0018). The incidence of instrument separation was significantly higher in group 5 than in groups 3 and 4 (P =.001). Preclinical training in the use of the PT technique at 300 rpm is crucial to prevent instrument separation and reduce the incidence of instrument deformation. The use of an electric high torque control motor is safe with the experienced operator.
Antiporda, Michael; Veenstra, Benjamin; Jackson, Chloe; Kandel, Pujan; Daniel Smith, C; Bowers, Steven P
2018-02-01
Repair of giant paraesophageal hernia (PEH) is associated with a favorably high rate of symptom improvement; however, rates of recurrence by objective measures remain high. Herein we analyze our experience with laparoscopic giant PEH repair to determine what factors if any can predict anatomic recurrence. We prospectively collected data on PEH characteristics, variations in operative techniques, and surgeon factors for 595 patients undergoing laparoscopic PEH repair from 2008 to 2015. Upper GI study was performed at 6 months postoperatively and selectively thereafter-any supra-diaphragmatic stomach was considered hiatal hernia recurrence. Exclusion criteria included revisional operation (22.4%), size <5 cm (17.6%), inadequate follow-up (17.8%), and confounding concurrent operations (6.9%). Inclusion criteria were met by 202 patients (31% male, median age 71 years, and median BMI 28.7). At a median follow-up of 6 months (IQR 6-12), overall anatomic recurrence rate was 34.2%. Symptom recurrence rate was 9.9% and revisional operation was required in ten patients (4.9%). Neither patient demographics nor PEH characteristics (size, presence of Cameron erosions, esophagitis, or Barrett's) correlated with anatomic recurrence. Technical factors at operation (mobilized intra-abdominal length of esophagus, Collis gastroplasty, number of anterior/posterior stitches, use of crural buttress, use of pledgeted or mattress sutures, or gastrostomy) were also not correlated with recurrence. Regarding surgeon factors, annual volume of fewer than ten cases per year was associated with increased risk of anatomic failure (54 vs 33%, P = 0.02). Multivariate analysis identified surgeon experience (<10 cases per year) as an independent factor associated with early hiatal hernia recurrence (OR 3.7, 95% CI 1.34-10.9). Laparoscopic repair of giant PEH is associated with high anatomic recurrence rate but excellent symptom control. PEH characteristics and technical operative variables do not appear to significantly affect rates of recurrence. In contrast, surgeon volume does appear to contribute significantly to durability of repair.
2014-01-01
Objectives This study aims to investigate the relationship between the total injury experience rate and socioeconomic status based on the fourth Korea National Health and Nutrition Examination Survey (KNHANES). Methods By analyzing data from the fourth KNHANES conducted from 2007 to 2009, we estimated the injury experience rate according to socioeconomic status, including the occupational characteristics of 11,837 subjects. Setting the injury experience rate as a dependent variable and socioeconomic status as an independent variable, we performed logistic regression to calculate odds ratios reflecting the likelihood of injury according to socioeconomic status while controlling for relevant covariates. Results In 797 subjects who had injury experience over the past 1 year, 290 persons (36.4%) had a work-related injury. As their income, home value, and educational status increased, their injury experiences decreased. Among occupational groups, the craft, equipment, machine operating, and assembling workers showed the highest rate (10.6%) of injury experience, and the lowest rate (5.7%) was found in the unemployed group. After adjusting for the confounding variables, the experience of injury was significantly related to several socioeconomic factors: high income (OR = 0.54; 95% CI: 0.34-0.86), high home value (OR = 0.65; 95% CI: 0.43-0.96), low education status (OR = 1.28; 95% CI: 1.07-1.52), and specific occupations such as craft, equipment, machine operating, and assembling work (OR = 1.99; 95% CI: 1.60-2.47), skilled agriculture, forestry and fishery work (OR = 1.43; 95% CI: 1.02-2.01), and simple labor (OR = 1.38; 95% CI: 1.04-1.82). Conclusions The injury experience rate differed depending on the socioeconomic status. A negative correlation was found between the injury experience rate and income, low home value, and education level. Moreover, a higher rate of injury experience was found in occupation groups and physical worker groups in comparison to the unemployed group and white-collar worker groups. This study would be useful in selecting appropriate priorities for injury management in Korea. PMID:24472308
NASA Astrophysics Data System (ADS)
Maljaars, E.; Felici, F.; Blanken, T. C.; Galperti, C.; Sauter, O.; de Baar, M. R.; Carpanese, F.; Goodman, T. P.; Kim, D.; Kim, S. H.; Kong, M.; Mavkov, B.; Merle, A.; Moret, J. M.; Nouailletas, R.; Scheffer, M.; Teplukhina, A. A.; Vu, N. M. T.; The EUROfusion MST1-team; The TCV-team
2017-12-01
The successful performance of a model predictive profile controller is demonstrated in simulations and experiments on the TCV tokamak, employing a profile controller test environment. Stable high-performance tokamak operation in hybrid and advanced plasma scenarios requires control over the safety factor profile (q-profile) and kinetic plasma parameters such as the plasma beta. This demands to establish reliable profile control routines in presently operational tokamaks. We present a model predictive profile controller that controls the q-profile and plasma beta using power requests to two clusters of gyrotrons and the plasma current request. The performance of the controller is analyzed in both simulation and TCV L-mode discharges where successful tracking of the estimated inverse q-profile as well as plasma beta is demonstrated under uncertain plasma conditions and the presence of disturbances. The controller exploits the knowledge of the time-varying actuator limits in the actuator input calculation itself such that fast transitions between targets are achieved without overshoot. A software environment is employed to prepare and test this and three other profile controllers in parallel in simulations and experiments on TCV. This set of tools includes the rapid plasma transport simulator RAPTOR and various algorithms to reconstruct the plasma equilibrium and plasma profiles by merging the available measurements with model-based predictions. In this work the estimated q-profile is merely based on RAPTOR model predictions due to the absence of internal current density measurements in TCV. These results encourage to further exploit model predictive profile control in experiments on TCV and other (future) tokamaks.
NASA Technical Reports Server (NTRS)
Malarik, Diane C.
2005-01-01
NASA Glenn Research Center s Telescience Support Center (TSC) allows researchers on Earth to operate experiments onboard the International Space Station (ISS) and the space shuttles. NASA s continuing investment in the required software, systems, and networks provides distributed ISS ground operations that enable payload developers and scientists to monitor and control their experiments from the Glenn TSC. The quality of scientific and engineering data is enhanced while the long-term operational costs of experiments are reduced because principal investigators and engineering teams can operate their payloads from their home institutions.
2017-05-25
Operations, and Unified Land Operations) and the US Army’s leader development model identifies how the education , training, and experience of field-grade...officers have failed in their incorporation of the framework because they lack the education , training, and experience for the use of the framework... education , training, and experience of field-grade officers at the division level have influenced their use of the operational framework. The cause for
Experiments and modelling of surge in small centrifugal compressor for automotive engines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galindo, J.; Serrano, J.R.; Climent, H.
2008-01-15
In this paper the surge phenomenon in small centrifugal compressors used for turbocharging internal combustion engines is analyzed. The experimental work was focused on the measurement of compressor behaviour within the surge zone by means of a specifically designed facility. The presented model is based on the introduction of a fluid inertia term that accounts for the non quasi steady effects and the use of a compressor map extended to the surge and negative flows zone obtained from experimental tests. The compressor model was implemented in a one-dimensional gas-dynamic model. The comparison of the modelled and measured evolution of instantaneousmore » pressure during deep surge operation shows good agreement. Furthermore, the model is also able to predict the amplitude and frequency of pressure pulses when the compressor operates in surge with different outlet duct lengths. (author)« less
The effect of membrane filtration on dissolved trace element concentrations
Horowitz, A.J.; Lum, K.R.; Garbarino, J.R.; Hall, G.E.M.; Lemieux, C.; Demas, C.R.
1996-01-01
The almost universally accepted operational definition for dissolved constituents is based on processing whole-water samples through a 0.45-??m membrane filter. Results from field and laboratory experiments indicate that a number of factors associated with filtration, other than just pore size (e.g., diameter, manufacturer, volume of sample processed, amount of suspended sediment in the sample), can produce substantial variations in the 'dissolved' concentrations of such elements as Fe, Al, Cu, Zn, Pb, Co, and Ni. These variations result from the inclusion/exclusion of colloidally- associated trace elements. Thus, 'dissolved' concentrations quantitated by analyzing filtrates generated by processing whole-water through similar pore- sized membrane filters may not be equal/comparable. As such, simple filtration through a 0.45-??m membrane filter may no longer represent an acceptable operational definition for dissolved chemical constituents. This conclusion may have important implications for environmental studies and regulatory agencies.
Reconstruction method for running shape of rotor blade considering nonlinear stiffness and loads
NASA Astrophysics Data System (ADS)
Wang, Yongliang; Kang, Da; Zhong, Jingjun
2017-10-01
The aerodynamic and centrifugal loads acting on the rotating blade make the blade configuration deformed comparing to its shape at rest. Accurate prediction of the running blade configuration plays a significant role in examining and analyzing turbomachinery performance. Considering nonlinear stiffness and loads, a reconstruction method is presented to address transformation of a rotating blade from cold to hot state. When calculating blade deformations, the blade stiffness and load conditions are updated simultaneously as blade shape varies. The reconstruction procedure is iterated till a converged hot blade shape is obtained. This method has been employed to determine the operating blade shapes of a test rotor blade and the Stage 37 rotor blade. The calculated results are compared with the experiments. The results show that the proposed method used for blade operating shape prediction is effective. The studies also show that this method can improve precision of finite element analysis and aerodynamic performance analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miles, T.R.; Miles, T.R. Jr.; Baxter, L.L.
1995-04-15
Alkali in the ash of annual crop biomass fuels creates serious fouling and slagging in conventional boilers. Even with the use of sorbents and other additives, power plants can only fire limited amounts of these fuels in combination with wood. The National Renewable Energy Laboratory (NREL), US Department of Energy, and the biomass power industry carried out eight full-scale firing tests and several laboratory experiments to study the nature and occurrence of deposits with the goal of increasing the quantities of these biofuels that can be used. This report describes the results of the laboratory and power plant tests thatmore » included: tracking and analyzing fuels and deposits by various methods; recording operating conditions; and extensive laboratory testing. The paper describes the occurrence of deposits, fuel and deposit analyses, boiler design and operation, fouling and slagging indicators, and recommendations. 37 refs., 41 figs., 17 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwarm, Samuel C.; Mburu, Sarah N.; Kolli, Ratna P.
Cast duplex stainless steel piping in light water nuclear reactors expe- rience thermal aging embrittlement during operational service. Interest in extending the operational life to 80 years requires an increased understanding of the microstructural evolution and corresponding changes in mechanical behavior. We analyze the evolution of the microstructure during thermal aging of cast CF-3 and CF-8 stainless steels using electron microscopy and atom probe tomography. The evolution of the mechanical properties is measured concurrently by mechanical methods such as tensile tests, Charpy V-notch tests, and instrumented nanoinden- tation. A microstructure-based finite element method model is developed and uti- lized inmore » conjunction with the characterization results in order to correlate the local stress-strain effects in the microstructure with the bulk measurements. This work is supported by the DOE Nuclear Energy University Programs (NEUP), contract number DE-NE0000724.« less
A Mathematical Model of Gas-Turbine Pump Complex
NASA Astrophysics Data System (ADS)
Shpilevoy, V. A.; Chekardovsky, S. M.; Zakirazkov, A. G.
2016-10-01
The articles analyzes the state of an extensive network of main oil pipelines of Tyumen region on the basis of statistical data, and also suggest ways of improving the efficiency of energy-saving policy on the main transport oil. Various types of main oil pipelines pump drives were examined. It was determined that now there is no strict analytical dependence between main operating properties of the power turbine of gas turbine engine. At the same time it is necessary to determine the operating parameters using a turbine at GTPU, interconnection between power and speed frequency, as well as the feasibility of using a particular mode. Analysis of foreign experience, the state of domestic enterprises supplying the country with gas turbines, features of the further development of transport of hydrocarbon resources allows us to conclude the feasibility of supplying the oil transportation industry of our country with pumping units based on gas turbine drive.
Tan, Qiulin; Fang, Jiahua; Liu, Wenyi; Xiong, Jijun; Zhang, Wendong
2015-01-01
Iron oxide (Fe2O3) nanopowder was prepared by a precipitation method and then mixed with different proportions of carbon nanotubes. The composite materials were characterized by X-ray powder diffraction, Fourier transform infrared spectroscopy and scanning electron microscopy. A fabricated heater-type gas sensor was compared with a pure Fe2O3 gas sensor under the influence of acetone. The effects of the amount of doping, the sintering temperature, and the operating temperature on the response of the sensor and the response recovery time were analyzed. Experiments show that doping of carbon nanotubes with iron oxide effectively improves the response of the resulting gas sensors to acetone gas. It also reduces the operating temperature and shortens the response recovery time of the sensor. The response of the sensor in an acetone gas concentration of 80 ppm was enhanced, with good repeatability. PMID:26569253
Tan, Qiulin; Fang, Jiahua; Liu, Wenyi; Xiong, Jijun; Zhang, Wendong
2015-11-11
Iron oxide (Fe₂O₃) nanopowder was prepared by a precipitation method and then mixed with different proportions of carbon nanotubes. The composite materials were characterized by X-ray powder diffraction, Fourier transform infrared spectroscopy and scanning electron microscopy. A fabricated heater-type gas sensor was compared with a pure Fe₂O₃ gas sensor under the influence of acetone. The effects of the amount of doping, the sintering temperature, and the operating temperature on the response of the sensor and the response recovery time were analyzed. Experiments show that doping of carbon nanotubes with iron oxide effectively improves the response of the resulting gas sensors to acetone gas. It also reduces the operating temperature and shortens the response recovery time of the sensor. The response of the sensor in an acetone gas concentration of 80 ppm was enhanced, with good repeatability.
Field Analysis of Microbial Contamination Using Three Molecular Methods in Parallel
NASA Technical Reports Server (NTRS)
Morris, H.; Stimpson, E.; Schenk, A.; Kish, A.; Damon, M.; Monaco, L.; Wainwright, N.; Steele, A.
2010-01-01
Advanced technologies with the capability of detecting microbial contamination remain an integral tool for the next stage of space agency proposed exploration missions. To maintain a clean, operational spacecraft environment with minimal potential for forward contamination, such technology is a necessity, particularly, the ability to analyze samples near the point of collection and in real-time both for conducting biological scientific experiments and for performing routine monitoring operations. Multiple molecular methods for detecting microbial contamination are available, but many are either too large or not validated for use on spacecraft. Two methods, the adenosine- triphosphate (ATP) and Limulus Amebocyte Lysate (LAL) assays have been approved by the NASA Planetary Protection Office for the assessment of microbial contamination on spacecraft surfaces. We present the first parallel field analysis of microbial contamination pre- and post-cleaning using these two methods as well as universal primer-based polymerase chain reaction (PCR).
Thermal modal analysis of novel non-pneumatic mechanical elastic wheel based on FEM and EMA
NASA Astrophysics Data System (ADS)
Zhao, Youqun; Zhu, Mingmin; Lin, Fen; Xiao, Zhen; Li, Haiqing; Deng, Yaoji
2018-01-01
A combination of Finite Element Method (FEM) and Experiment Modal Analysis (EMA) have been employed here to characterize the structural dynamic response of mechanical elastic wheel (ME-Wheel) operating under a specific thermal environment. The influence of high thermal condition on the structural dynamic response of ME-Wheel is investigated. The obtained results indicate that the EMA results are in accordance with those obtained using the proposed Finite Element (FE) model, indicting the high reliability of this FE model applied in analyzing the modal of ME-Wheel working under practical thermal environment. It demonstrates that the structural dynamic response of ME-Wheel operating under a specific thermal condition can be predicted and evaluated using the proposed analysis method, which is beneficial for the dynamic optimization design of the wheel structure to avoid tire temperature related vibration failure and improve safety of tire.
Cognitive context detection in UAS operators using eye-gaze patterns on computer screens
NASA Astrophysics Data System (ADS)
Mannaru, Pujitha; Balasingam, Balakumar; Pattipati, Krishna; Sibley, Ciara; Coyne, Joseph
2016-05-01
In this paper, we demonstrate the use of eye-gaze metrics of unmanned aerial systems (UAS) operators as effective indices of their cognitive workload. Our analyses are based on an experiment where twenty participants performed pre-scripted UAS missions of three different difficulty levels by interacting with two custom designed graphical user interfaces (GUIs) that are displayed side by side. First, we compute several eye-gaze metrics, traditional eye movement metrics as well as newly proposed ones, and analyze their effectiveness as cognitive classifiers. Most of the eye-gaze metrics are computed by dividing the computer screen into "cells". Then, we perform several analyses in order to select metrics for effective cognitive context classification related to our specific application; the objective of these analyses are to (i) identify appropriate ways to divide the screen into cells; (ii) select appropriate metrics for training and classification of cognitive features; and (iii) identify a suitable classification method.
Rocket-borne time-of-flight mass spectrometry
NASA Technical Reports Server (NTRS)
Reiter, R. F.
1976-01-01
Theoretical and numerical analyses are made of planar, cylindrical and spherical-electrode two-field time-of-flight mass spectrometers in order to optimize their operating conditions. A method is introduced which can improve the resolving power of these instruments by a factor of 7.5. Potential barrier gating in time-of-flight mass spectrometers is also analyzed. Experimental studies of a miniature cylindrical-electrode and a hemispherical-electrode time-of-flight mass spectrometer are presented. Their sensitivity and ability to operate at D-region pressures with an open source make them ideal instruments for D-region ion composition measurements. A sounding rocket experiment package carrying a cylindrical electrode time-of-flight mass spectrometer was launched. The data indicate that essentially 100% of the positive electric charge on positive ions is carried by ions with mass-to-charge ratios greater than 500 below an altitude of 92 km. These heavy charge carriers were present at altitudes up to about 100 km.
A Plasma Diagnostic Set for the Study of a Variable Specific Impulse Magnetoplasma Rocket
NASA Astrophysics Data System (ADS)
Squire, J. P.; Chang-Diaz, F. R.; Bengtson Bussell, R., Jr.; Jacobson, V. T.; Wootton, A. J.; Bering, E. A.; Jack, T.; Rabeau, A.
1997-11-01
The Advanced Space Propulsion Laboratory (ASPL) is developing a Variable Specific Impulse Magnetoplasma Rocket (VASIMR) using an RF heated magnetic mirror operated asymmetrically. We will describe the initial set of plasma diagnostics and data acquisition system being developed and installed on the VASIMR experiment. A U.T. Austin team is installing two fast reciprocating probes: a quadruple Langmuir and a Mach probe. These measure electron density and temperature profiles, electrostatic plasma fluctuations, and plasma flow profiles. The University of Houston is developing an array of 20 highly directional Retarding Potential Analyzers (RPA) for measuring ion energy distribution function profiles in the rocket plume, giving a measurement of total thrust. We have also developed a CAMAC based data acquisition system using LabView running on a Power Macintosh communicating through a 2 MB/s serial highway. We will present data from initial plasma operations and discuss future diagnostic development.
Treatment of emulsified oils by electrocoagulation: pulsed voltage applications.
Genc, Ayten; Bakirci, Busra
2015-01-01
The effect of pulsed voltage application on energy consumption during electrocoagulation was investigated. Three voltage profiles having the same arithmetic average with respect to time were applied to the electrodes. The specific energy consumption for these profiles were evaluated and analyzed together with oil removal efficiencies. The effects of applied voltages, electrode materials, electrode configurations, and pH on oil removal efficiency were determined. Electrocoagulation experiments were performed by using synthetic and real wastewater samples. The pulsed voltages saved energy during the electrocoagulation process. In continuous operation, energy saving was as high as 48%. Aluminum electrodes used for the treatment of emulsified oils resulted in higher oil removal efficiencies in comparison with stainless steel and iron electrodes. When the electrodes gap was less than 1 cm, higher oil removal efficiencies were obtained. The highest oil removal efficiencies were 95% and 35% for the batch and continuous operating modes, respectively.
Report on SNL RCBC control options
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ponciroli, R.; Vilim, R. B.
The attractive performance of the S-CO 2 recompression cycle arises from the thermo-physical properties of carbon dioxide near the critical point. However, to ensure efficient operation of the cycle near the critical point, precise control of the heat removal rate by the Printed Circuit Heat Exchanger (PCHE) upstream of the main compressor is required. Accomplishing this task is not trivial because of the large variations in fluid properties with respect to temperature and pressure near the critical point. The use of a model-based approach for the design of a robust feedback regulator is being investigated to achieve acceptable control ofmore » heat removal rate at different operating conditions. A first step in this procedure is the development of a dynamic model of the heat exchanger. In this work, a one-dimensional (1-D) control-oriented model of the PCHE was developed using the General Plant Analyzer and System Simulator (GPASS) code. GPASS is a transient simulation code that supports analysis and control of power conversion cycles based on the S-CO 2 Brayton cycle. This modeling capability was used this fiscal year to analyze experiment data obtained from the heat exchanger in the SNL recompression Brayton cycle. The analysis suggested that the error in the water flowrate measurement was greater than required for achieving precise control of heat removal rate. Accordingly, a new water flowmeter was installed, significantly improving the quality of the measurement. Comparison of heat exchanger measurements in subsequent experiments with code simulations yielded good agreement establishing a reliable basis for the use of the GPASS PCHE model for future development of a model-based feedback controller.« less
Hroncová, Emília; Ladomerský, Juraj; Musil, Juraj
2018-03-01
Currently, it is necessary to deal with issues related to the emissions as there is a constantly increasing interest in combusting sludge from sewage treatment plants in the boilers for wood. An analysis of the energetic importance of the combustion of sewage sludge has already been carried out, but the effects of various treatments of the sludge are not always clear, e.g. composting and subsequent combustion to the air pollution. Investments in other thermal processes of energetic utilisation of sewage sludge and organic waste are not always successfully implemented. The objective of this paper is to point out some problematic cases for acceptance of thermal processes related to energetic use of waste in terms of the air protection. The other aim is to mention the experience with solutions of such issues in Slovakia. There are mentioned first results of the operational validation experiments during the energy generation in circulating fluidized bed boiler in peaking power plant (Power 110MW) with the addition of the so-called alternative fuel based on wood and sewage sludge to the main fuel - black coal (anthracite). And there has already been achieved the highest share of 12.4%w. (dry matter) of sewage sludge in form of compost in blend with black coal, which is technologically viable. Moreover analyzed the problems of the authorization and operation of the co-combustion of sewage sludge and of combustion of products of various kinds of pyrolysis waste - pyrolysis gas and pyrolysis oil are analyzed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of a Telemetric, Miniaturized Electrochemical Amperometric Analyzer.
Jung, Jaehyo; Lee, Jihoon; Shin, Siho; Kim, Youn Tae
2017-10-23
In this research, we developed a portable, three-electrode electrochemical amperometric analyzer that can transmit data to a PC or a tablet via Bluetooth communication. We performed experiments using an indium tin oxide (ITO) glass electrode to confirm the performance and reliability of the analyzer. The proposed analyzer uses a current-to-voltage (I/V) converter to convert the current generated by the reduction-oxidation (redox) reaction of the buffer solution to a voltage signal. This signal is then digitized by the processor. The configuration of the power and ground of the printed circuit board (PCB) layer is divided into digital and analog parts to minimize the noise interference of each part. The proposed analyzer occupies an area of 5.9 × 3.25 cm² with a current resolution of 0.4 nA. A potential of 0~2.1 V can be applied between the working and the counter electrodes. The results of this study showed the accuracy of the proposed analyzer by measuring the Ruthenium(III) chloride ( Ru III ) concentration in 10 mM phosphate-buffered saline (PBS) solution with a pH of 7.4. The measured data can be transmitted to a PC or a mobile such as a smartphone or a tablet PC using the included Bluetooth module. The proposed analyzer uses a 3.7 V, 120 mAh lithium polymer battery and can be operated for 60 min when fully charged, including data processing and wireless communication.
Development of a Telemetric, Miniaturized Electrochemical Amperometric Analyzer
Lee, Jihoon; Shin, Siho; Kim, Youn Tae
2017-01-01
In this research, we developed a portable, three-electrode electrochemical amperometric analyzer that can transmit data to a PC or a tablet via Bluetooth communication. We performed experiments using an indium tin oxide (ITO) glass electrode to confirm the performance and reliability of the analyzer. The proposed analyzer uses a current-to-voltage (I/V) converter to convert the current generated by the reduction-oxidation (redox) reaction of the buffer solution to a voltage signal. This signal is then digitized by the processor. The configuration of the power and ground of the printed circuit board (PCB) layer is divided into digital and analog parts to minimize the noise interference of each part. The proposed analyzer occupies an area of 5.9 × 3.25 cm2 with a current resolution of 0.4 nA. A potential of 0~2.1 V can be applied between the working and the counter electrodes. The results of this study showed the accuracy of the proposed analyzer by measuring the Ruthenium(III) chloride (RuIII) concentration in 10 mM phosphate-buffered saline (PBS) solution with a pH of 7.4. The measured data can be transmitted to a PC or a mobile such as a smartphone or a tablet PC using the included Bluetooth module. The proposed analyzer uses a 3.7 V, 120 mAh lithium polymer battery and can be operated for 60 min when fully charged, including data processing and wireless communication. PMID:29065534
Applying AI tools to operational space environmental analysis
NASA Technical Reports Server (NTRS)
Krajnak, Mike; Jesse, Lisa; Mucks, John
1995-01-01
The U.S. Air Force and National Oceanic Atmospheric Agency (NOAA) space environmental operations centers are facing increasingly complex challenges meeting the needs of their growing user community. These centers provide current space environmental information and short term forecasts of geomagnetic activity. Recent advances in modeling and data access have provided sophisticated tools for making accurate and timely forecasts, but have introduced new problems associated with handling and analyzing large quantities of complex data. AI (Artificial Intelligence) techniques have been considered as potential solutions to some of these problems. Fielding AI systems has proven more difficult than expected, in part because of operational constraints. Using systems which have been demonstrated successfully in the operational environment will provide a basis for a useful data fusion and analysis capability. Our approach uses a general purpose AI system already in operational use within the military intelligence community, called the Temporal Analysis System (TAS). TAS is an operational suite of tools supporting data processing, data visualization, historical analysis, situation assessment and predictive analysis. TAS includes expert system tools to analyze incoming events for indications of particular situations and predicts future activity. The expert system operates on a knowledge base of temporal patterns encoded using a knowledge representation called Temporal Transition Models (TTM's) and an event database maintained by the other TAS tools. The system also includes a robust knowledge acquisition and maintenance tool for creating TTM's using a graphical specification language. The ability to manipulate TTM's in a graphical format gives non-computer specialists an intuitive way of accessing and editing the knowledge base. To support space environmental analyses, we used TAS's ability to define domain specific event analysis abstractions. The prototype system defines events covering reports of natural phenomena such as solar flares, bursts, geomagnetic storms, and five others pertinent to space environmental analysis. With our preliminary event definitions we experimented with TAS's support for temporal pattern analysis using X-ray flare and geomagnetic storm forecasts as case studies. We are currently working on a framework for integrating advanced graphics and space environmental models into this analytical environment.
Using a Red Team to devise countermeasures
NASA Astrophysics Data System (ADS)
Swedenburg, R. L.
1995-01-01
The ability of a defense system to operate effectively when deployed in battle is dependent on designs able to deal with countermeasures against the defense. The formation of a technical Red Team to stress the preliminary designs of the defensive system with technologically feasible and effective potential countermeasures provides a means to identify such potential countermeasures. This paper describes the experience of the U.S. Ballistic Missile Defense Organization's (BMDO) Theater Missile Defense Red Team since the Gulf War in 1991, the Red-Blue Exchange process, and the value it has provided to the designers of the U.S. Theater Missile Defense systems for developing robust systems. A wide-range of technologically feasible countermeasures has been devised, analyzed, tested for feasibility, and provided to the system developers for mitigation design. The process for independently analyzing possible susceptibilities of preliminary designs and exploiting the susceptibilities to identify possible countermeasures is explained. Designing and characterizing the Red Team's countermeasures, determining their feasibility, and analyzing their potential effectiveness against the defense are explained. A technique for the Blue Team's designers to deal with a wide range of potential countermeasures is explained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Jing; Xianyu, Zhong-Zhi; He, Hong-Jian, E-mail: jingren2004@gmail.com, E-mail: xianyuzhongzhi@gmail.com, E-mail: hjhe@tsinghua.edu.cn
2014-06-01
We study gravitational interaction of Higgs boson through the unique dimension-4 operator ξH{sup †}HR, with H the Higgs doublet and R the Ricci scalar curvature. We analyze the effect of this dimensionless nonminimal coupling ξ on weak gauge boson scattering in both Jordan and Einstein frames. We explicitly establish the longitudinal-Goldstone equivalence theorem with nonzero ξ coupling in both frames, and analyze the unitarity constraints. We study the ξ-induced weak boson scattering cross sections at O(1−30) TeV scales, and propose to probe the Higgs-gravity coupling via weak boson scattering experiments at the LHC (14 TeV) and the next generation ppmore » colliders (50-100 TeV). We further extend our study to Higgs inflation, and quantitatively derive the perturbative unitarity bounds via coupled channel analysis, under large field background at the inflation scale. We analyze the unitarity constraints on the parameter space in both the conventional Higgs inflation and the improved models in light of the recent BICEP2 data.« less
Coronel, María Lorena; Chamorro, Núria; Blanco, Isabel; Amado, Verónica; Del Pozo, Roberto; Pomar, José Luis; Badia, Joan Ramón; Rovira, Irene; Matute, Purificación; Argemí, Gemma; Castellà, Manuel; Barberà, Joan Albert
2014-12-01
Pulmonary endarterectomy (PE) is the treatment of choice for chronic thromboembolic pulmonary hypertension (CTEPH). The aim of this study was to analyze our experience in the medical and surgical management of CTEPH. We included 80 patients diagnosed with CTEPH between January 2000 and July 2012. Thirty two patients underwent PE and 48 received medical treatment (MT). We analyzed functional class (FC), six-minute walking distance (6MWD) and pulmonary hemodynamics. Mortality in both groups and periods were analyzed. Patients who underwent PE were younger, mostly men, and had longer 6MWD. No differences were observed in pulmonary hemodynamics or FC at diagnosis. One year after treatment, all PE patients versus 41% in MT group were at FCI-II. At follow-up, the PE group showed greater increase in 6MWD, and greater reduction in mean pulmonary arterial pressure and pulmonary vascular resistance than the MT group (P<.05). Overall survival in the MT group at 1 and 5years was 83% and 69%, respectively. Conditional survival in patients alive 100days post-PE at 1 and 5years was 95% and 88%, respectively. Surgical mortality in operated patients in the first period (2000-2006) was 31,3%, and 6,3% in the second (2007-2012). PE provides good clinical results, and improves pulmonary hemodynamics in patients who successfully overcome the immediate postoperative period. After a learning period, the current operatory mortality in our center is similar to international standards. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.
Effect of the 80-hour work week on resident operative experience in general surgery.
Carlin, Arthur M; Gasevic, Enej; Shepard, Alexander D
2007-03-01
The goal of this study was to determine the effect of the 80-hour work week on resident operative experience. General surgery resident operative experience was evaluated during a 4-year period and divided into 2 groups: before (group A [July 1, 2001, to June 30, 2003]) and after (group B July 1, 2003, to June 30, 2005]) implementation of the Accreditation Council for Graduate Medical Education duty hour guidelines. There was a significant decrease in mean total and primary surgeon cases in group B for postgraduate year (PGY) levels 1, 2, and 4 (P < or = .001). There was a significant decrease in PGY 5 teaching assistant and PGY 1 first assistant experience in group B (P < or = .001). There was no difference in PGY 3 resident operative volume. The mandated work-hour guidelines have negatively impacted the operative experience of general surgery residents, especially at the junior level. Despite implementing modifications designed to optimize resident operative experience, surgical training programs may require further adaptations.
Lan, Roy H; Kamath, Atul F
2017-01-01
Medical evaluation pre-operatively is an important component of risk stratification and potential risk optimization. However, the effect of timing prior to surgical intervention is not well-understood. We hypothesized that total hip arthroplasty (THA) patients seen in pre-operative evaluation closer to the date of surgery would experience better perioperative outcomes. We retrospectively reviewed 167 elective THA patients to study the relationship between the number of days between pre-operative evaluation (range, 0-80 days) and surgical intervention. Patients' demographics, length of stay (LOS), ICU admission frequency, and rate of major complications were recorded. When pre-operative evaluation carried out 4 days or less before the procedure date, there was a significant reduction in LOS (3.91 vs. 4.49; p=0.03). When pre-operative evaluation carried out 11 days or less prior to the procedure date, there was a four-fold decrease in rate of intensive care admission (p=0.04). Furthermore, the major complication rate also significantly reduced (p<0.05). However, when pre-operative evaluation took place 30 days or less before the procedure date compared to more than 30 days prior, there were no significant changes in the outcomes. From this study, pre-operative medical evaluation closer to the procedure date was correlated with improved selected peri-operative outcomes. However, further study on larger patient groups must be done to confirm this finding. More study is needed to define the effect on rare events like infection, and to analyze the subsets of THA patients with modifiable risk factors that may be time-dependent and need further time to optimization.
NASA Astrophysics Data System (ADS)
Nagaoka, Kenji; Yano, Hajime; Yoshimitsu, Tetsuo; Yoshida, Kazuya; Kubota, Takashi; Adachi, Tadashi; Kurisu, Masamitsu; Yatsunami, Hiroyuki; Kuroda, Yoji
This presentation introduces the analysis and evaluation of a deployment mechanism of a tiny rover by ZARM drop tower experiments. The mechanism is installed on the MINERVA-II2 system in the Hayabusa-2 project performed by JAXA. The MINERVA-II2 system includes a small exploration rover, and the rover will be released from the Hayabusa-2 spacecraft to the asteroid surface. After the rover lands on the surface, it will move over the surface and conduct scientific measurements. To achieve such a challenging mission, the deployment mechanism of the rover is one of the significant components. In particular, controlling the rover's landing velocity against the asteroid surface is required with high-reliability mechanism. In the MINERVA-II2 system, a reliable deployment mechanism using a metal spring is installed. By the simple mechanism, the rover's releasing velocity will be controlled within a required value. Although the performance evaluation and analysis are necessary before launch, it is difficult to experiment the deployment performance three-dimensionally on ground. In the MINERVA-II2 project, with the cooperation of ZARM, DLR and JAXA, we conducted microgravity experiments using a ZARM drop tower to examine the deployment performance in a three-dimensional microgravity. During the experiments, motion of the deployment mechanism and the rover were captured by an external camera mounted on the dropping chamber. After the drop, we analyzed the rover's releasing velocity based on image processing of the camera data. The experimental results confirmed that the deployment mechanism is feasible and reliable for controlling the rover's releasing velocity. In addition to the experiments, we analyzed a mechanical friction resistance of the mechanism from a theoretical viewpoint. These results contribute to design of spring stiffness and feedback to the development of the MINERVA-II2 flight model. Finally, the drop tower experiments were accomplished based on the agreement on the Hayabusa-2 project by DLR-JAXA. The chamber for the experiments was used, which was developed by the Hayabusa-2 project. In the experiments, we received technical and operations supports from ZARM. We sincerely express our acknowledgement to ZARM, DLR and JAXA.
A compiler and validator for flight operations on NASA space missions
NASA Astrophysics Data System (ADS)
Fonte, Sergio; Politi, Romolo; Capria, Maria Teresa; Giardino, Marco; De Sanctis, Maria Cristina
2016-07-01
In NASA missions the management and the programming of the flight systems is performed by a specific scripting language, the SASF (Spacecraft Activity Sequence File). In order to perform a check on the syntax and grammar it is necessary a compiler that stress the errors (eventually) found in the sequence file produced for an instrument on board the flight system. In our experience on Dawn mission, we developed VIRV (VIR Validator), a tool that performs checks on the syntax and grammar of SASF, runs a simulations of VIR acquisitions and eventually finds violation of the flight rules of the sequences produced. The project of a SASF compiler (SSC - Spacecraft Sequence Compiler) is ready to have a new implementation: the generalization for different NASA mission. In fact, VIRV is a compiler for a dialect of SASF; it includes VIR commands as part of SASF language. Our goal is to produce a general compiler for the SASF, in which every instrument has a library to be introduced into the compiler. The SSC can analyze a SASF, produce a log of events, perform a simulation of the instrument acquisition and check the flight rules for the instrument selected. The output of the program can be produced in GRASS GIS format and may help the operator to analyze the geometry of the acquisition.
New York State Public Health System Response to Hurricane Sandy: Lessons From the Field.
Shipp Hilts, Asante; Mack, Stephanie; Eidson, Millicent; Nguyen, Trang; Birkhead, Guthrie S
2016-06-01
The aim of this study was to conduct interviews with public health staff who responded to Hurricane Sandy and to analyze their feedback to assess response strengths and challenges and recommend improvements for future disaster preparedness and response. Qualitative analysis was conducted of information from individual confidential interviews with 35 staff from 3 local health departments in New York State (NYS) impacted by Hurricane Sandy and the NYS Department of Health. Staff were asked about their experiences during Hurricane Sandy and their recommendations for improvements. Open coding was used to analyze interview transcripts for reoccurring themes, which were labeled as strengths, challenges, or recommendations and then categorized into public health preparedness capabilities. The most commonly cited strengths, challenges, and recommendations related to the Hurricane Sandy public health response in NYS were within the emergency operations coordination preparedness capability, which includes the abilities of health department staff to partner among government agencies, coordinate with emergency operation centers, conduct routine conference calls with partners, and manage resources. Health departments should ensure that emergency planning includes protocols to coordinate backup staffing, delineation of services that can be halted during disasters, clear guidelines to coordinate resources across agencies, and training for transitioning into unfamiliar disaster response roles. (Disaster Med Public Health Preparedness. 2016;10:443-453).
Coaxial Plasma Gun Development for the ARPA-E PLX- α Project
NASA Astrophysics Data System (ADS)
Witherspoon, F. Douglas; Case, Andrew; Brockington, Samuel
2015-11-01
We describe the renewed effort to design and build coaxial plasma guns appropriate for a scaling study of spherically imploding plasma liners as a standoff magneto-inertial-fusion driver under the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. HyperV joins LANL, UAH, UNM, BNL, and Tech-X to develop, build, operate and analyze a 60 plasma gun experiment using the existing PLX facility at LANL. The guns will be designed to operate over a scaling range of operating parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 1016 -1017 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each gun is planned to incorporate contoured gaps, fast dense gas injection and triggering, and innovative integral sparkgap switching and pfn configurations to reduce inductance, cost, and complexity, and to increase efficiency and system reliability. We will describe the overall design approach for the guns and pulsed power systems. This work supported by the ARPA-E ALPHA Program.
NASA Astrophysics Data System (ADS)
Liu, Lei; Huang, Chuanhui; Yu, Ping; Zhang, Lei
2017-10-01
To improve the dynamic characteristics and cavitation characteristics of large-flow pilot operated check valve, consider the pilot poppet as the research object, analyses working principle and design three different kinds of pilot poppets. The vibration characteristics and impact characteristics are analyzed. The simulation model is established through flow field simulation software. The cavitation characteristics of large-flow pilot operated check valve are studied and discussed. On this basis, high-pressure large-flow impact experimental system is used for impact experiment, and the cavitation index is discussed. Then optimal structure is obtained. Simulation results indicate that the increase of pilot poppet half cone angle can effectively reduce the cavitation area, reducing the generation of cavitation. Experimental results show that the pressure impact is not decreasing with increasing of pilot poppet half cone angle in process of unloading, but the unloading capacity, response speed and pilot poppet half cone angle are positively correlated. The impact characteristics of 60° pilot poppet, and its cavitation index is lesser, which indicates 60° pilot poppet is the optimal structure, with the theory results are basically identical.
The Laparoscopic Approach in the Treatment of Diverticular Colon Disease
del Olmo, J. C. Martin; Blanco, J. I.; de la Cuesta, C.; Atienza, R.
1998-01-01
Background and Objectives: The experience with treatment of diverticular colon disease (DCD) by the laparoscopic method is analyzed. Methods: Between January 1994 and July 1997, a group of 22 patients with criteria for symptomatic diverticular disease in the descending and sigmoid colon underwent laparoscopy with average resections of 40 cm. Intra-abdominal mechanical anastomosis completed the procedure. Results: The operative morbidity was 28%. Two cases, in acute diverticulitis phase, were reconverted to open surgery, and three cases presented postoperative rectorrhagia which ceased spontaneously. No long-term complications have been found. Postoperative hospitalization was 4-8 days (mean 5.5) and mean operative time was 165 minutes (range 120-240). Conclusions: Nevertheless, the learning curve precise to practice this type of surgery, the acceptable morbity-mortality rates which the laparoscopic method presents, especially with these high-risk groups of patients (age > 65, high blood pressure, etc), encouraged us to modified the criteria indicating surgery for the disease, offering first choice operative treatment with efficiency and safety. However, we feel that those patients with acute complications of diverticular colon disease must be excluded initially for laparoscopic approach. PMID:9876730
Initial evaluation of the "Trauma surgery course"
Tugnoli, Gregorio; Ribaldi, Sergio; Casali, Marco; Calderale, Stefano M; Coletti, Massimo; Alifano, Marco; Parri, Sergio N Forti; Villani, Silvia; Biscardi, Andrea; Giordano, M Chiara; Baldoni, Franco
2006-01-01
Background The consequence of the low rate of penetrating injuries in Europe and the increase in non-operative management of blunt trauma is a decrease in surgeons' confidence in managing traumatic injuries has led to the need for new didactic tools. The aim of this retrospective study was to present the Corso di Chirurgia del Politrauma (Trauma Surgery Course), developed as a model for teaching operative trauma techniques, and assess its efficacy. Method the two-day course consisted of theoretical lectures and practical experience on large-sized swine. Data of the first 126 participants were collected and analyzed. Results All of the 126 general surgeons who had participated in the course judged it to be an efficient model to improve knowledge about the surgical treatment of trauma. Conclusion A two-day course, focusing on trauma surgery, with lectures and life-like operation situations, represents a model for simulated training and can be useful to improve surgeons' confidence in managing trauma patients. Cooperation between organizers of similar initiatives would be beneficial and could lead to standardizing and improving such courses. PMID:16759403
NASA Technical Reports Server (NTRS)
Lee, Hyun H.
2012-01-01
MERTELEMPROC processes telemetered data in data product format and generates Experiment Data Records (EDRs) for many instruments (HAZCAM, NAVCAM, PANCAM, microscopic imager, Moessbauer spectrometer, APXS, RAT, and EDLCAM) on the Mars Exploration Rover (MER). If the data is compressed, then MERTELEMPROC decompresses the data with an appropriate decompression algorithm. There are two compression algorithms (ICER and LOCO) used in MER. This program fulfills a MER specific need to generate Level 1 products within a 60-second time requirement. EDRs generated by this program are used by merinverter, marscahv, marsrad, and marsjplstereo to generate higher-level products for the mission operations. MERTELEPROC was the first GDS program to process the data product. Metadata of the data product is in XML format. The software allows user-configurable input parameters, per-product processing (not streambased processing), and fail-over is allowed if the leading image header is corrupted. It is used within the MER automated pipeline. MERTELEMPROC is part of the OPGS (Operational Product Generation Subsystem) automated pipeline, which analyzes images returned by in situ spacecraft and creates level 1 products to assist in operations, science, and outreach.
Operational Axioms for Quantum Mechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Ariano, Giacomo Mauro; Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL 60208
2007-02-21
The mathematical formulation of Quantum Mechanics in terms of complex Hilbert space is derived for finite dimensions, starting from a general definition of physical experiment and from five simple Postulates concerning experimental accessibility and simplicity. For the infinite dimensional case, on the other hand, a C*-algebra representation of physical transformations is derived, starting from just four of the five Postulates via a Gelfand-Naimark-Segal (GNS) construction. The present paper simplifies and sharpens the previous derivation in Ref. [1]. The main ingredient of the axiomatization is the postulated existence of faithful states that allows one to calibrate the experimental apparatus. Such notionmore » is at the basis of the operational definitions of the scalar product and of the transposed of a physical transformation. What is new in the present paper with respect to Ref. [1], is the operational deduction of an involution corresponding to the complex-conjugation for effects, whose extension to transformations allows to define the adjoint of a transformation when the extension is composition-preserving. The existence of such composition-preserving extension among possible extensions is analyzed.« less
Operating Ferret on a patrol boat
NASA Astrophysics Data System (ADS)
Bédard, Jacques
2006-05-01
Ferret is an acoustic system that detects, recognizes and localizes the source and direction of small arms fire. The system comprises a small array of microphones and pressure sensors connected to a standard PC-104 computer that analyzes, displays, reports and logs the parameters of a recognized shot. The system operates by detecting and recognizing the ballistic shock waves created by the supersonic bullet, combined with the muzzle blast wave propagating from the weapon. The system was recently installed and tested on a patrol boat operated by the Royal Canadian Mounted Police (RCMP). An electronic compass with tilt compensation and a GPS was incorporated into the system. This allows the system to correct for the motion of the boat and provide the full coordinates of the shooter. The system also updates the azimuth to the shooter in real time as the boat turns. This paper presents the results of our test and evaluation based on a live firing experiment. Ferret is the result of a collaborative effort by Defence R&D Canada and MacDonald Dettwiler and Associates.
Laparoscopic Donor Nephrectomy: Early Experience at a Single Center in Pakistan.
Mohsin, Rehan; Shehzad, Asad; Bajracharya, Uspal; Ali, Bux; Aziz, Tahir; Mubarak, Muhammed; Hashmi, Altaf; Rizvi, Adibul Hasan
2018-04-01
Laparoscopic donor nephrectomy has become the criterion standard for kidney retrieval from living donors. There is no information on the experience and outcomes of laparoscopic donor nephrectomy in Pakistan. The objective of the study was to identify benefits and harms of using laparoscopic compared with open nephrectomy techniques for renal allograft retrieval. In this a retrospective study, patient files from May 2014 to September 2015 were analyzed. Patients were divided into 2 groups: those with open donor nephrectomy and those with laparoscopic donor nephrectomy. Donor case files and operative notes were analyzed for age, sex, laterality, body mass index, warm ischemia time, perioperative and postoperative complications, surgery time, and length of hospital stay. Finally, serum creatinine patterns of both donors and recipients were analyzed. Data were analyzed using SPSS version 10 (SPSS: An IBM Company, IBM Corporation, Armonk, NY, USA). Of 388 total donors, 190 (49%) had open donor nephrectomy and 198 (51%) had laparoscopic donor nephrectomy. For both groups, most donors were older than 25 years with male preponderance. Left-to-right kidney donation ratio was markedly higher in the laparoscopic group than in the open donor nephrectomy group, with 6 cases of double renal artery also included in this study. There were no significant differences in surgery times between the 2 groups, whereas the laparoscopic donor nephrectomy group had shorter hospital stay. Analgesic requirements were markedly shorter in the laparoscopic donor nephrectomy group. The 1-year graft function was not significantly different between the 2 groups. The results for laparoscopic donor nephrectomy were comparable to those for open donor nephrectomy, and its acceptability was high. Laparoscopic donor nephrectomy should be the preferred approach for procuring the kidney graft.
CATE: A Case Study of an Interdisciplinary Student-Led Microgravity Experiment
NASA Astrophysics Data System (ADS)
Colwell, J. E.; Dove, A.; Lane, S. S.; Tiller, C.; Whitaker, A.; Lai, K.; Hoover, B.; Benjamin, S.
2015-12-01
The Collisional Accretion Experiment (CATE) was designed, built, and flown on NASA's C-9 parabolic flight airplane in less than a year by an interdisciplinary team of 6 undergraduate students under the supervision of two faculty. CATE was selected in the initial NASA Undergraduate Student Instrument Project (USIP) solicitation in the Fall of 2013, and the experiment flight campaign was in July 2014. The experiment studied collisions between different particle populations at low velocities (sub-m/s) in a vacuum and microgravity to gain insight into processes in the protoplanetary disk and planetary ring systems. Faculty provided the experiment concept and key experiment design parameters, and the student team developed the detailed hardware design for all components, manufactured and tested hardware, operated the experiment in flight, and analyzed data post-flight. Students also developed and led an active social media campaign and education and public outreach campaign to engage local high school students in the project. The ability to follow an experiment through from conception to flight was a key benefit for undergraduate students whose available time for projects such as this is frequently limited to their junior and senior years. Key factors for success of the program included having an existing laboratory infrastructure and experience in developing flight payloads and an intrinsically simple experiment concept. Students were highly motivated, in part, by their sense of technical and scientific ownership of the project, and this engagement was key to the project's success.
Design of control software for the closed ecology experiment facilities (CEEF)
NASA Astrophysics Data System (ADS)
Miyajima, H.; Abe, K.; Hirosaki, T.; Ishikawa, Y.
A habitation experiment using a closed ecology experiment facilities CEEF was started in fiscal 2005 three experiments in which two humans stayed for one week were conducted Their stays will be extended gradually until fiscal 2009 when an experiment will be launched with two humans staying for four months The CEEF has an ambitious target of acquiring the technology of an advanced life support system and the system is being developed based on the technology of conventional plant systems Especially in respect to supervision and control of the system the system still has little automation This system has many manual operation parts whose starts and stops are determined by human judgment There are even several parts requiring off-line measurements that include analyses performed by hand At present a CEEF behavioral prediction system CPS is being developed as the first stage for controlling such a system In this CPS an operator creates an operational schedule after due consideration However creation of the operational schedule of the complex CEEF is not easy and it is above the operator s capability to fully cope with alterations of the operational schedule that occur during a long-term habitation experiment Therefore we are going to develop an automatic creation function of the operational schedule that will be incorporated into the CPS by the beginning of the habitation experiment in fiscal 2009 This function will enable automation of most of the operational schedule that human operators currently set up In this paper we examine
Svrakic, Maja; Roland, J Thomas; McMenomey, Sean O; Svirsky, Mario A
2016-12-01
To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE). Retrospective review. Tertiary referral center. Sixty-three MSE implants in pediatric and adult patients were compared with age- and sex-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. Cochlear implantation with either the AB 1j electrode or the AB MSE. The MSE and 1j electrodes were compared in their angular depth of insertion and pre to postoperative change in hearing thresholds. Hearing preservation was analyzed as a function of angular depth of insertion. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2000 Hz were 10, 7, 2, and 6 dB smaller for the MSE electrode than for the 1j (p < 0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect.
2017-01-01
Purpose. The purpose of this study is to evaluate the learning curve of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures, to provide valuable information and experience for surgeons who decide to learn a new procedure. Methods. We retrospectively analyzed data from 53 patients who underwent surgery using an InterTan intramedullary nail at our hospital between July 2012 and September 2015. The negative exponential curve-fit regression analysis was used to evaluate the learning curve. According to 90% learning milestone, patients were divided into two group, and the outcomes were compared. Results. The mean operative time was 69.28 (95% CI 64.57 to 74.00) minutes; with the accumulation of surgical experience, the operation time was gradually decreased. 90% of the potential improvement was expected after 18 cases. In terms of operative time, intraoperative blood loss, hospital stay, and Harris hip score significant differences were found between two groups (p = 0.009, p = 0.000, p = 0.030, and p = 0.002, resp.). Partial weight bearing time, fracture union time, tip apex distance, and the number of blood transfusions and complications were similar between two groups (p > 0.5). Conclusion. This study demonstrated that the learning curve of performing surgery with the InterTan intramedullary nail is acceptable and 90% of the expert's proficiency level is achieved at around 18 cases. PMID:28503572
Probandari, Ari; Mahendradhata, Yodi; Widjanarko, Bagoes; Alisjahbana, Bachti
2017-01-01
The Tuberculosis Operational Research Group (TORG) implemented a capacity-building model involving academics and practitioners (i.e. clinicians or program staff) in an operational research (OR) team in Indonesia. This study explored academics' and practitioners' perspectives regarding the benefits of participating in a tuberculosis (TB) OR capacity-building program in Indonesia. We conducted a qualitative study involving in-depth interviews with 36 academics and 23 practitioners undertaking the TORG capacity-building program. We asked open-ended questions about their experience of the program. Data were analyzed via content analysis. The findings demonstrated the social multiplier effects of the OR capacity-building program. Both academics and practitioners reported perceived improvements in research knowledge, skills, and experience, and described additional individual- and institutional-level benefits. The individual-level benefits level included improvements in understanding of the TB program, motivation for research and self-satisfaction, the development/enhancement of individual networking, receipt of recognition, and new opportunities. The additional benefits reported at an institutional level included improvement in research curricula, in-house training, and program management and the development/enhancement of institutional partnerships. The program improved not only individuals' capacity for conducting OR but also the quality of the TB program management and public health education. OR should be included in research methodology curricula for postgraduate public health/disease control programs. The capacity-building model, in which academics and program staff collaborated within an OR team, should be promoted.
NASA/ESA CT-990 Spacelab simulation. Appendix A: The experiment operator
NASA Technical Reports Server (NTRS)
Reller, J. O., Jr.; Neel, C. B.; Haughney, L. C.
1976-01-01
A joint NASA/ESA endeavor was established to conduct an extensive spacelab simulation using the NASA CV-990 airborne laboratory. The scientific payload was selected to perform studies in upper atmospheric physics and infrared astronomy with principal investigators from France, the Netherlands, England, and several groups from the United States. Two experiment operators from Europe and two from the U.S. were selected to live aboard the aircraft along with a mission manager for a six-day period and operate the experiments in behalf of the principal scientists. This appendix discusses the experiment operators and their relationship to the joint mission under the following general headings: selection criteria, training programs, and performance. The performance of the proxy operators was assessed in terms of adequacy of training, amount of scientific data obtained, quality of data obtained, and reactions to problems that arose in experiment operation.
Effects of D-cycloserine on the extinction of appetitive operant learning
Vurbic, Drina; Gold, Benjamin; Bouton, Mark E.
2011-01-01
Four experiments with rat subjects examined whether D-cycloserine (DCS), a partial NMDA agonist, facilitates the extinction of operant lever-pressing reinforced by food. Previous research has demonstrated that DCS facilitates extinction learning with methods that involve Pavlovian extinction. In the current experiments, operant conditioning occurred in Context A, extinction in Context B, and then testing occurred in both the extinction and conditioning contexts. Experiments 1a and 1b tested the effects of three doses of DCS (5, 15, and 30 mg/kg) on the extinction of lever pressing trained as a free operant. Experiment 2 examined their effects when extinction of the free operant was conducted in the presence of non-response-contingent deliveries of the reinforcer (which theoretically reduced the role of generalization decrement in suppressing responding). Experiment 3 examined their effects on extinction of a discriminated operant, i.e., one that had been reinforced in the presence of a discriminative stimulus, but not in its absence. A strong ABA renewal effect was observed in all four experiments during testing. However, despite the use of DCS doses and a drug administration procedure that facilitates the extinction of Pavlovian learning, there was no evidence in any experiment that DCS facilitated operant extinction learning assessed in either the extinction or the conditioning context. DCS may primarily facilitate learning processes that underlie Pavlovian, rather than purely operant, extinction. PMID:21688894
The purpose of this SOP is to describe the procedures for operating and calibrating the Spectrace 9000 field portable X-ray fluorescence analyzer. This procedure applies to the determination of metal concentrations in samples during the Arizona NHEXAS project and the "Border" st...
NASA Astrophysics Data System (ADS)
Urbancic, T.; Bosman, K.; Baig, A. M.; Viegas, G. F.
2016-12-01
In response to a number of high-profile incidents of induced seismicity related to petroleum operations, several jurisdictions have enacted regulations requiring modification or temporary shut-down of operations of wells near significant earthquakes. However, these regulations are based on earthquake magnitude alone, and generally local (or Richter) magnitude (ML) if specified at all. We discuss two earthquakes which occurred near Fox Creek, Alberta, Canada, in close proximity to hydraulic fracturing operations, as examples of some complications which may arise in analyzing suspected induced events. For an event that occurred on June 13, 2015, detailed magnitude assessments were performed by two groups in addition to moment magnitude (MW) estimates from the USGS and NRCan. The resulting magnitudes vary between MW3.9- 4.6, thus some estimates would trigger the shut-down regulations in Alberta (M > 4), while some merely require operational modifications (2 < M < 4). Using data from the RAVEN network, we have analyzed an event which occurred on January 12, 2016. We calculate a magnitude of MW4.3 for this event, which agrees within error with estimates from NRCan (MW4.4) and the USGS (Mb4.2). All magnitude estimates for the January 12, 2016 event exceed the threshold for operational shut-down in Alberta. Comparing the spectral amplitude measured at each station to existing standards from the former United States Bureau of Mines and the Uniform Building Code, we determine that structures within 35km of the epicenter may experience light damage due to this earthquake, depending on local soil conditions. Stress drops observed for the events analyzed were 6MPa and 13MPa, in line with typical tectonic events and in contrast to the low values observed for suspected wastewater-injection induced events. This suggests the events were driven by stress redistribution rather than direct influence of fluids. Theoretical source spectra illustrate the profound effect of stress drop on ground motion. Due to the extreme difficulty of predicting the source characteristics of future induced events, regulating based on magnitude alone appears to be an overly simplistic approach. Regulations incorporating observed ground motion provide a more appropriate method of assessing the potential damage resulting from induced seismicity.
10 Steps to Building an Architecture for Space Surveillance Projects
NASA Astrophysics Data System (ADS)
Gyorko, E.; Barnhart, E.; Gans, H.
Space surveillance is an increasingly complex task, requiring the coordination of a multitude of organizations and systems, while dealing with competing capabilities, proprietary processes, differing standards, and compliance issues. In order to fully understand space surveillance operations, analysts and engineers need to analyze and break down their operations and systems using what are essentially enterprise architecture processes and techniques. These techniques can be daunting to the first- time architect. This paper provides a summary of simplified steps to analyze a space surveillance system at the enterprise level in order to determine capabilities, services, and systems. These steps form the core of an initial Model-Based Architecting process. For new systems, a well defined, or well architected, space surveillance enterprise leads to an easier transition from model-based architecture to model-based design and provides a greater likelihood that requirements are fulfilled the first time. Both new and existing systems benefit from being easier to manage, and can be sustained more easily using portfolio management techniques, based around capabilities documented in the model repository. The resulting enterprise model helps an architect avoid 1) costly, faulty portfolio decisions; 2) wasteful technology refresh efforts; 3) upgrade and transition nightmares; and 4) non-compliance with DoDAF directives. The Model-Based Architecting steps are based on a process that Harris Corporation has developed from practical experience architecting space surveillance systems and ground systems. Examples are drawn from current work on documenting space situational awareness enterprises. The process is centered on DoDAF 2 and its corresponding meta-model so that terminology is standardized and communicable across any disciplines that know DoDAF architecting, including acquisition, engineering and sustainment disciplines. Each step provides a guideline for the type of data to collect, and also the appropriate views to generate. The steps include 1) determining the context of the enterprise, including active elements and high level capabilities or goals; 2) determining the desired effects of the capabilities and mapping capabilities against the project plan; 3) determining operational performers and their inter-relationships; 4) building information and data dictionaries; 5) defining resources associated with capabilities; 6) determining the operational behavior necessary to achieve each capability; 7) analyzing existing or planned implementations to determine systems, services and software; 8) cross-referencing system behavior to operational behavioral; 9) documenting system threads and functional implementations; and 10) creating any required textual documentation from the model.
Single center experience in selecting the laparoscopic Frey procedure for chronic pancreatitis.
Tan, Chun-Lu; Zhang, Hao; Li, Ke-Zhou
2015-11-28
To share our experience regarding the laparoscopic Frey procedure for chronic pancreatitis (CP) and patient selection. All consecutive patients undergoing duodenum-preserving pancreatic head resection from July 2013 to July 2014 were reviewed and those undergoing the Frey procedure for CP were included in this study. Data on age, gender, body mass index (BMI), American Society of Anesthesiologists score, imaging findings, inflammatory index (white blood cells, interleukin (IL)-6, and C-reaction protein), visual analogue score score during hospitalization and outpatient visit, history of CP, operative time, estimated blood loss, and postoperative data (postoperative mortality and morbidity, postoperative length of hospital stay) were obtained for patients undergoing laparoscopic surgery. The open surgery cases in this study were analyzed for risk factors related to extensive bleeding, which was the major reason for conversion during the laparoscopic procedure. Age, gender, etiology, imaging findings, amylase level, complications due to pancreatitis, functional insufficiency, and history of CP were assessed in these patients. Nine laparoscopic and 37 open Frey procedures were analyzed. Of the 46 patients, 39 were male (85%) and seven were female (16%). The etiology of CP was alcohol in 32 patients (70%) and idiopathic in 14 patients (30%). Stones were found in 38 patients (83%). An inflammatory mass was found in five patients (11%). The time from diagnosis of CP to the Frey procedure was 39 ± 19 (9-85) mo. The BMI of patients in the laparoscopic group was 20.4 ± 1.7 (17.8-22.4) kg/m(2) and was 20.6 ± 2.9 (15.4-27.7) kg/m(2) in the open group. All patients required analgesic medication for abdominal pain. Frequent acute pancreatitis or severe abdominal pain due to acute exacerbation occurred in 20 patients (43%). Pre-operative complications due to pancreatitis were observed in 18 patients (39%). Pancreatic functional insufficiency was observed in 14 patients (30%). Two laparoscopic patients (2/9) were converted. In seven successful laparoscopic cases, the mean operative time was 323 ± 29 (290-370) min. Estimated intra-operative blood loss was 57 ± 14 (40-80) mL. One patient had a postoperative complication, and no mortality was observed. Postoperative hospital stay was 7 ± 2 (5-11) d. Multiple linear regression analysis of 37 open Frey procedures showed that an inflammatory mass (P < 0.001) and acute exacerbation (P < 0.001) were risk factors for intra-operative blood loss. The laparoscopic Frey procedure for CP is feasible but only suitable in carefully selected patients.
Single center experience in selecting the laparoscopic Frey procedure for chronic pancreatitis
Tan, Chun-Lu; Zhang, Hao; Li, Ke-Zhou
2015-01-01
AIM: To share our experience regarding the laparoscopic Frey procedure for chronic pancreatitis (CP) and patient selection. METHODS: All consecutive patients undergoing duodenum-preserving pancreatic head resection from July 2013 to July 2014 were reviewed and those undergoing the Frey procedure for CP were included in this study. Data on age, gender, body mass index (BMI), American Society of Anesthesiologists score, imaging findings, inflammatory index (white blood cells, interleukin (IL)-6, and C-reaction protein), visual analogue score score during hospitalization and outpatient visit, history of CP, operative time, estimated blood loss, and postoperative data (postoperative mortality and morbidity, postoperative length of hospital stay) were obtained for patients undergoing laparoscopic surgery. The open surgery cases in this study were analyzed for risk factors related to extensive bleeding, which was the major reason for conversion during the laparoscopic procedure. Age, gender, etiology, imaging findings, amylase level, complications due to pancreatitis, functional insufficiency, and history of CP were assessed in these patients. RESULTS: Nine laparoscopic and 37 open Frey procedures were analyzed. Of the 46 patients, 39 were male (85%) and seven were female (16%). The etiology of CP was alcohol in 32 patients (70%) and idiopathic in 14 patients (30%). Stones were found in 38 patients (83%). An inflammatory mass was found in five patients (11%). The time from diagnosis of CP to the Frey procedure was 39 ± 19 (9-85) mo. The BMI of patients in the laparoscopic group was 20.4 ± 1.7 (17.8-22.4) kg/m2 and was 20.6 ± 2.9 (15.4-27.7) kg/m2 in the open group. All patients required analgesic medication for abdominal pain. Frequent acute pancreatitis or severe abdominal pain due to acute exacerbation occurred in 20 patients (43%). Pre-operative complications due to pancreatitis were observed in 18 patients (39%). Pancreatic functional insufficiency was observed in 14 patients (30%). Two laparoscopic patients (2/9) were converted. In seven successful laparoscopic cases, the mean operative time was 323 ± 29 (290-370) min. Estimated intra-operative blood loss was 57 ± 14 (40-80) mL. One patient had a postoperative complication, and no mortality was observed. Postoperative hospital stay was 7 ± 2 (5-11) d. Multiple linear regression analysis of 37 open Frey procedures showed that an inflammatory mass (P < 0.001) and acute exacerbation (P < 0.001) were risk factors for intra-operative blood loss. CONCLUSION: The laparoscopic Frey procedure for CP is feasible but only suitable in carefully selected patients. PMID:26640341
Terminal-area STOL operating systems experiments program
NASA Technical Reports Server (NTRS)
Smith, D. W.; Watson, D.; Christensen, J. V.
1973-01-01
Information which will aid in the choice by the U.S. Government and industry of system concepts, design criteria, operating procedures for STOL aircraft and STOL ports, STOL landing guidance systems, air traffic control systems, and airborne avionics and flight control systems. Ames has developed a terminal-area STOL operating systems experiments program which is a part of the joint DOT/NASA effort is discussed. The Ames operating systems experiments program, its objectives, the program approach, the program schedule, typical experiments, the research facilities to be used, and the program status are described.
The lived experiences of adolescents with sickle cell disease in Kingston, Jamaica.
Forrester, Andrea Brown; Barton-Gooden, Antoinette; Pitter, Cynthia; Lindo, Jascinth L M
2015-01-01
To explore the lived experiences of adolescents with sickle cell disease, in Kingston, Jamaica. A descriptive qualitative design was used for this research. In-depth interviews were conducted with six adolescents with sickle cell disease at a Sickle Cell Unit operated by the University of the West Indies. Interviews were audiotaped, transcribed, and thematically analyzed. The majority of the adolescents demonstrated a positive self-concept. They reported strong family, school, and peer support which made them feel accepted. All were actively engaged in social activities such as parties, but had challenges participating in sporting activities. Various coping strategies were utilized to address challenges of the disease including praying, watching television, and surfing the Internet. Sickle cell disease can be very challenging for the adolescent, but with positive self-concept and increased social support, especially from family and peers, these adolescents were able to effectively cope with their condition and live productive lives.
Computational modeling of mediator oxidation by oxygen in an amperometric glucose biosensor.
Simelevičius, Dainius; Petrauskas, Karolis; Baronas, Romas; Razumienė, Julija
2014-02-07
In this paper, an amperometric glucose biosensor is modeled numerically. The model is based on non-stationary reaction-diffusion type equations. The model consists of four layers. An enzyme layer lies directly on a working electrode surface. The enzyme layer is attached to an electrode by a polyvinyl alcohol (PVA) coated terylene membrane. This membrane is modeled as a PVA layer and a terylene layer, which have different diffusivities. The fourth layer of the model is the diffusion layer, which is modeled using the Nernst approach. The system of partial differential equations is solved numerically using the finite difference technique. The operation of the biosensor was analyzed computationally with special emphasis on the biosensor response sensitivity to oxygen when the experiment was carried out in aerobic conditions. Particularly, numerical experiments show that the overall biosensor response sensitivity to oxygen is insignificant. The simulation results qualitatively explain and confirm the experimentally observed biosensor behavior.
Computational Modeling of Mediator Oxidation by Oxygen in an Amperometric Glucose Biosensor
Šimelevičius, Dainius; Petrauskas, Karolis; Baronas, Romas; Julija, Razumienė
2014-01-01
In this paper, an amperometric glucose biosensor is modeled numerically. The model is based on non-stationary reaction-diffusion type equations. The model consists of four layers. An enzyme layer lies directly on a working electrode surface. The enzyme layer is attached to an electrode by a polyvinyl alcohol (PVA) coated terylene membrane. This membrane is modeled as a PVA layer and a terylene layer, which have different diffusivities. The fourth layer of the model is the diffusion layer, which is modeled using the Nernst approach. The system of partial differential equations is solved numerically using the finite difference technique. The operation of the biosensor was analyzed computationally with special emphasis on the biosensor response sensitivity to oxygen when the experiment was carried out in aerobic conditions. Particularly, numerical experiments show that the overall biosensor response sensitivity to oxygen is insignificant. The simulation results qualitatively explain and confirm the experimentally observed biosensor behavior. PMID:24514882
Enhanced DIII-D Data Management Through a Relational Database
NASA Astrophysics Data System (ADS)
Burruss, J. R.; Peng, Q.; Schachter, J.; Schissel, D. P.; Terpstra, T. B.
2000-10-01
A relational database is being used to serve data about DIII-D experiments. The database is optimized for queries across multiple shots, allowing for rapid data mining by SQL-literate researchers. The relational database relates different experiments and datasets, thus providing a big picture of DIII-D operations. Users are encouraged to add their own tables to the database. Summary physics quantities about DIII-D discharges are collected and stored in the database automatically. Meta-data about code runs, MDSplus usage, and visualization tool usage are collected, stored in the database, and later analyzed to improve computing. Documentation on the database may be accessed through programming languages such as C, Java, and IDL, or through ODBC compliant applications such as Excel and Access. A database-driven web page also provides a convenient means for viewing database quantities through the World Wide Web. Demonstrations will be given at the poster.
Briukhanov, A F; Zaĭtsev, A A; Babenyshev, B V; Protsenko, S L; Abgarian, G P; Solodovnikov, B V; Lebedev, K K; Maevskiĭ, M P; Antonov, A V; Sukhov, V V; Grizhebovskiĭ, G M; Evchenko, Iu M
2001-01-01
The experience of use of efforts and resources by the bacteriological section of the specialized antiepidemic brigade of the Stavropol Research Institute for Plague Control in the Chechen Republic during the period of 1999-2000 under the conditions of the emergency situation, formed as the consequence of carrying out the antiterrorist operation, is summarized. The work load falling of the bacteriological section in different shifts, the structure of bacteriological investigations, as well as some problems arising in the process of work, were analyzed. The experience showed the necessity of the complete accommodation of the bacteriological laboratory in specialized motor-vehicle modules having all necessary equipment for investigation works, disinfection, sterilization. The brigade sent to its mission should be given concrete tasks with a view to ensure the adequate supply of the bacteriological section with diagnostic preparations, materials and equipment.
Atlas of TOMS ozone data collected during the Genesis of Atlantic Lows Experiment (GALE), 1986
NASA Technical Reports Server (NTRS)
Larko, David E.; Uccellini, Louis W.; Krueger, Arlin J.
1986-01-01
Data from the TOMS (Total Ozone Mapping Spectrometer) instrument aboard the Nimbus-7 satellite were collected daily in real time during the GALE (Genesis of Atlantic Lows Experiment) from January 15 through March 15, l986. The TOMS ozone data values were processed into GEMPAK format and transferred from the Goddard Space Flight Center to GALE operations in Raleigh-Durham, NC, in as little as three hours for use, in part, to direct aircraft research flights recording in situ measurements of ozone and water vapor in areas of interest. Once in GEMPAK format, the ozone values were processed into gridded form using the Barnes objective analysis scheme and contour plots of the ozone created. This atlas provides objectively analyzed contour plots of the ozone for each of the sixty days of GALE as well as four-panel presentations of the ozone analysis combined on the basis of GALE Intensive Observing Periods (IOP's).
Photovoltaic module reliability improvement through application testing and failure analysis
NASA Technical Reports Server (NTRS)
Dumas, L. N.; Shumka, A.
1982-01-01
During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.