Sample records for angiography multicenteric randomized

  1. Arterial Obstruction on Computed Tomographic or Magnetic Resonance Angiography and Response to Intravenous Thrombolytics in Ischemic Stroke

    PubMed Central

    Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M.; Adams, Matthew E.; Yan, Bernard; Demchuk, Andrew M.; Farrall, Andrew J.; Sellar, Robin J.; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I.; Sandercock, Peter A.G.

    2017-01-01

    Background and Purpose— Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. Methods— We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. Results— In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18–3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58–1.35; P=0.566) arterial obstruction (P for interaction 0.017). Conclusions— Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. Clinical Trial Registration— URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. PMID:28008093

  2. Arterial Obstruction on Computed Tomographic or Magnetic Resonance Angiography and Response to Intravenous Thrombolytics in Ischemic Stroke.

    PubMed

    Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M; Adams, Matthew E; Yan, Bernard; Demchuk, Andrew M; Farrall, Andrew J; Sellar, Robin J; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I; Sandercock, Peter A G; Wardlaw, Joanna M

    2017-02-01

    Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18-3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58-1.35; P=0.566) arterial obstruction (P for interaction 0.017). Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. © 2016 The Authors.

  3. A randomized-controlled trial examining the effects of reflexology on anxiety of patients undergoing coronary angiography.

    PubMed

    Molavi Vardanjani, Mehdi; Masoudi Alavi, Negin; Razavi, Narges Sadat; Aghajani, Mohammad; Azizi-Fini, Esmail; Vaghefi, Seied Morteza

    2013-09-01

    The anxiety reduction before coronary angiography has clinical advantages and is one of the objectives of nursing. Reflexology is a non-invasive method that has been used in several clinical situations. Applying reflexology might have effect on the reduction of anxiety before coronary angiography. The aim of this randomized clinical trial was to investigate the effect of reflexology on anxiety among patients undergoing coronary angiography. This trial was conducted in Shahid Beheshti Hospital, in Kashan, Iran. One hundred male patients who were undergoing coronary angiography were randomly enrolled into intervention and placebo groups. The intervention protocol was included 30 minutes of general foot massage and the stimulation of three reflex points including solar plexus, pituitary gland, and heart. The placebo group only received the general foot massage. Spielbergers state trait anxiety inventory was used to assess the anxiety experienced by patients. Data was analyzed using Man-Witney, Wilcoxon and Chi-square tests. The stepwise multiple regressions used to analyze the variables that are involved in anxiety reduction. The mean range of anxiety decreased from 53.24 to 45.24 in reflexology group which represented 8 score reduction (P = 0.0001). The reduction in anxiety was 5.9 score in placebo group which was also significant (P = 0.0001). The anxiety reduction was significantly higher in reflexology group (P = 0.014). The stepwise multiple regression analysis showed that doing reflexology can explain the 7.5% of anxiety reduction which made a significant model. Reflexology can decrease the anxiety level before coronary angiography. Therefore, reflexology before coronary angiography is recommended.

  4. Relative efficacy and safety of ticagelor vs clopidogrel as a function of time to invasive management in non-ST-segment elevation acute coronary syndrome in the PLATO trial.

    PubMed

    Pollack, Charles V; Davoudi, Farideh; Diercks, Deborah B; Becker, Richard C; James, Stefan K; Lim, Soo Teik; Schulte, Phillip J; Spinar, Jindrich; Steg, Philippe Gabriel; Storey, Robert F; Himmelmann, Anders; Wallentin, Lars; Cannon, Christopher P

    2017-06-01

    Guidelines suggest that "upstream" P2Y 12 receptor antagonists should be considered in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS). Early use of ticagrelor in patients managed with an invasive strategy would be more effective than clopidogrel because of its more rapid onset of action and greater potency. In the PLATO trial, 6792 NSTE-ACS patients were randomized to ticagrelor or clopidogrel (started prior to angiography) and underwent angiography within 72 hours of randomization. We compared efficacy and safety outcomes of ticagrelor vs clopidogrel as a function of "early" (<3h) vs "late" (≥3h) time to angiography. Adjusted Cox proportional hazards models evaluated interaction between randomized treatment and time from randomization to angiography on subsequent outcomes. Overall, a benefit of ticagrelor vs clopidogrel for cardiovascular death/myocardial infarction/stroke was seen at day 7 (hazard ratio [HR]: 0.67, P = 0.002), day 30 (HR: 0.81, P = 0.042), and 1 year (HR: 0.80, P = 0.0045). There were no significant interactions in the <3h vs ≥3h groups at any timepoint. For major bleeding, overall there was no significant increase (HR: 1.04, 95% confidence interval: 0.85-1.27); but there was a significant interaction with no difference between ticagrelor and clopidogrel in the early group (HR: 0.79), but higher bleeding risk with ticagrelor in the late angiography group, at 7 days (HR: 1.51, P int = 0.002). Patterns were similar at 30 days and 1 year. The benefit of ticagrelor over clopidogrel was consistent in those undergoing early and late angiography, supporting upstream use of ticagrelor. © 2017 Wiley Periodicals, Inc.

  5. A Randomized-Controlled Trial Examining the Effects of Reflexology on Anxiety of Patients Undergoing Coronary Angiography

    PubMed Central

    Molavi Vardanjani, Mehdi; Masoudi Alavi, Negin; Razavi, Narges Sadat; Aghajani, Mohammad; Azizi-Fini, Esmail; Vaghefi, Seied Morteza

    2013-01-01

    Background: The anxiety reduction before coronary angiography has clinical advantages and is one of the objectives of nursing. Reflexology is a non-invasive method that has been used in several clinical situations. Applying reflexology might have effect on the reduction of anxiety before coronary angiography. Objectives: The aim of this randomized clinical trial was to investigate the effect of reflexology on anxiety among patients undergoing coronary angiography. Patients and Methods: This trial was conducted in Shahid Beheshti Hospital, in Kashan, Iran. One hundred male patients who were undergoing coronary angiography were randomly enrolled into intervention and placebo groups. The intervention protocol was included 30 minutes of general foot massage and the stimulation of three reflex points including solar plexus, pituitary gland, and heart. The placebo group only received the general foot massage. Spielbergers state trait anxiety inventory was used to assess the anxiety experienced by patients. Data was analyzed using Man-Witney, Wilcoxon and Chi-square tests. The stepwise multiple regressions used to analyze the variables that are involved in anxiety reduction. Results: The mean range of anxiety decreased from 53.24 to 45.24 in reflexology group which represented 8 score reduction (P = 0.0001). The reduction in anxiety was 5.9 score in placebo group which was also significant (P = 0.0001). The anxiety reduction was significantly higher in reflexology group (P = 0.014). The stepwise multiple regression analysis showed that doing reflexology can explain the 7.5% of anxiety reduction which made a significant model. Conclusions: Reflexology can decrease the anxiety level before coronary angiography. Therefore, reflexology before coronary angiography is recommended. PMID:25414869

  6. Security Policy and Infrastructure in the Context of a Multi-Centeric Information System Dedicated to Autism Spectrum Disorder.

    PubMed

    Ben Said, Mohamed; Robel, Laurence; Golse, Bernard; Jais, Jean Philippe

    2017-01-01

    Autism spectrum disorders (ASD) are complex neuro-developmental disorders affecting children in their early age. The diagnosis of ASD relies on multidisciplinary investigations, in psychiatry, neurology, genetics, electrophysiology, neuro-imagery, audiology and ophthalmology. In order to support clinicians, researchers and public health decision makers, we designed an information system dedicated to ASD, called TEDIS. TEDIS was designed to manage systematic, exhaustive and continuous multi-centric patient data collection via secured Internet connections. In this paper, we present the security policy and security infrastructure we developed to protect ASD' patients' clinical data and patients' privacy. We tested our system on 359 ASD patient records in a local secured intranet environment and showed that the security system is functional, with a consistent, transparent and safe encrypting-decrypting behavior. It is ready for deployment in the nine ASD expert assessment centers in the Ile de France district.

  7. Laser-assisted indocyanine green angiography: a critical appraisal.

    PubMed

    Wu, Cindy; Kim, Sendia; Halvorson, Eric G

    2013-05-01

    Laser-assisted indocyanine green angiography (ICG-A) has been promoted to assess perfusion of random skin, pedicled, and free flaps. Few studies address its potential limitations. Thirty-seven patients who underwent reconstructive procedures with ICG-A were studied retrospectively to determine the correlation between clinical findings and ICG-A. Indocyanine green angiography underestimated perfusion when areas of less than or equal to 25% uptake were not debrided and remained perfused. Indocyanine green angiography overestimated perfusion when areas with greater than 25% uptake developed necrosis. Of 14 random skin flaps, ICG-A underestimated perfusion in 14% and overestimated in 14%. In 16 patients undergoing perforator flap breast reconstruction, ICG-A correlated with computed tomographic angiogram (CTA) in 85%. Indocyanine green angiography underestimated perfusion in 7% and overestimated in 7%. In 8/11 patients undergoing fasciocutaneous flaps, ICG-A aided in donor site selection. In 3/6 ALT flaps, a better unilateral blush was found that correlated with Doppler. In all 3, a dominant perforator was found. In 11 patients, there was a 9% underestimation of flap perfusion. In 3 pedicled flaps, there was a 66% underestimation and 33% overestimation of perfusion. Indocyanine green angiography often confirmed our clinical/radiologic findings in abdominal perforator and fasciocutaneous flaps. It tended to underestimate perfusion in pedicle and skin flaps. When clinical examination was obvious, ICG-A rendered clear-cut findings. When clinical examination was equivocal, ICG-A tended to provide ambiguous findings, demonstrating that a distinct cutoff point does not exists for every patient or flap. Indocyanine green angiography is a promising but expensive technology that would benefit from standardization. Further research is needed before ICG-A can become a reliable tool for surgeons.

  8. Fractional flow reserve vs. angiography in guiding management to optimize outcomes in non-ST-segment elevation myocardial infarction: the British Heart Foundation FAMOUS–NSTEMI randomized trial

    PubMed Central

    Layland, Jamie; Oldroyd, Keith G.; Curzen, Nick; Sood, Arvind; Balachandran, Kanarath; Das, Raj; Junejo, Shahid; Ahmed, Nadeem; Lee, Matthew M.Y.; Shaukat, Aadil; O'Donnell, Anna; Nam, Julian; Briggs, Andrew; Henderson, Robert; McConnachie, Alex; Berry, Colin; Hannah, Andrew; Stewart, Andrew; Metcalfe, Malcolm; Norrie, John; Chowdhary, Saqib; Clark, Andrew; Henderson, Robert; Balachandran, Kanarath; Berry, Colin; Baird, Gordon; O'Donnell, Anna; Sood, Arvind; Curzen, Nick; Das, Raj; Ford, Ian; Layland, Jamie; Junejo, Shahid; Oldroyd, Keith

    2015-01-01

    Aim We assessed the management and outcomes of non-ST segment elevation myocardial infarction (NSTEMI) patients randomly assigned to fractional flow reserve (FFR)-guided management or angiography-guided standard care. Methods and results We conducted a prospective, multicentre, parallel group, 1 : 1 randomized, controlled trial in 350 NSTEMI patients with ≥1 coronary stenosis ≥30% of the lumen diameter assessed visually (threshold for FFR measurement) (NCT01764334). Enrolment took place in six UK hospitals from October 2011 to May 2013. Fractional flow reserve was disclosed to the operator in the FFR-guided group (n = 176). Fractional flow reserve was measured but not disclosed in the angiography-guided group (n = 174). Fractional flow reserve ≤0.80 was an indication for revascularization by percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG). The median (IQR) time from the index episode of myocardial ischaemia to angiography was 3 (2, 5) days. For the primary outcome, the proportion of patients treated initially by medical therapy was higher in the FFR-guided group than in the angiography-guided group [40 (22.7%) vs. 23 (13.2%), difference 95% (95% CI: 1.4%, 17.7%), P = 0.022]. Fractional flow reserve disclosure resulted in a change in treatment between medical therapy, PCI or CABG in 38 (21.6%) patients. At 12 months, revascularization remained lower in the FFR-guided group [79.0 vs. 86.8%, difference 7.8% (−0.2%, 15.8%), P = 0.054]. There were no statistically significant differences in health outcomes and quality of life between the groups. Conclusion In NSTEMI patients, angiography-guided management was associated with higher rates of coronary revascularization compared with FFR-guided management. A larger trial is necessary to assess health outcomes and cost-effectiveness. PMID:25179764

  9. Optimal timing of coronary angiography and potential intervention in non-ST-elevation acute coronary syndromes.

    PubMed

    Katritsis, Demosthenes G; Siontis, George C M; Kastrati, Adnan; van't Hof, Arnoud W J; Neumann, Franz-Josef; Siontis, Konstantinos C M; Ioannidis, John P A

    2011-01-01

    An invasive approach is superior to medical management for the treatment of patients with acute coronary syndromes without ST-segment elevation (NSTE-ACS), but the optimal timing of coronary angiography and subsequent intervention, if indicated, has not been settled. We conducted a meta-analysis of randomized trials addressing the optimal timing (early vs. delayed) of coronary angiography in NSTE-ACS. Four trials with 4013 patients were eligible (ABOARD, ELISA, ISAR-COOL, TIMACS), and data for longer follow-up periods than those published became available for this meta-analysis by the ELISA and ISAR-COOL investigators. The median time from admission or randomization to coronary angiography ranged from 1.16 to 14 h in the early and 20.8-86 h in the delayed strategy group. No statistically significant difference of risk of death [random effects risk ratio (RR) 0.85, 95% confidence interval (CI) 0.64-1.11] or myocardial infarction (MI) (RR 0.94, 95% CI 0.61-1.45) was detected between the two strategies. Early intervention significantly reduced the risk for recurrent ischaemia (RR 0.59, 95% CI 0.38-0.92, P = 0.02) and the duration of hospital stay (by 28%, 95% CI 22-35%, P < 0.001). Furthermore, decreased major bleeding events (RR 0.78, 95% CI 0.57-1.07, P = 0.13), and less major events (death, MI, or stroke) (RR 0.91, 95% CI 0.82-1.01, P = 0.09) were observed with the early strategy but these differences were not nominally significant. Early coronary angiography and potential intervention reduces the risk of recurrent ischaemia, and shortens hospital stay in patients with NSTE-ACS.

  10. Effectiveness of Chinese Hand Massage on Anxiety Among Patients Awaiting Coronary Angiography: A Randomized Controlled Trial.

    PubMed

    Mei, Lijuan; Miao, Xing; Chen, Haiying; Huang, Xiufang; Zheng, Guohua

    Anxiety is the most common negative emotion among the patients awaiting coronary angiography. The increased anxiety may exacerbate coronary heart disease symptoms and possibly contribute to complications during the procedure. Chinese hand massage is a nonpharmaceutical intervention that has been used in several clinical situations in China and might have beneficial effects on reducing anxiety before coronary angiography. The aim of this study was to evaluate the effectiveness and safety of Chinese hand massage care on anxiety among patients awaiting coronary angiography. One hundred eighty-five subjects awaiting coronary angiography in a single hospital in Fuzhou, China, between May 2012 and September 2012 were screened. One hundred eligible participants were recruited and randomly assigned into the control or Chinese hand massage group. The control group received the conventional therapies and care according to the guidelines, and those in the Chinese hand massage group received additional Chinese hand massage care in conjunction with the same conventional therapies and care as the control group. The anxiety scores (evaluated by using the Hamilton Anxiety Rating Scale), heart rate, blood pressure, quality of life (Short-Form Health Survey), and the adverse events were recorded at the baseline and after coronary angiography, respectively. The scores of Hamilton Anxiety Rating Scale in the Chinese hand massage group (11.78 [SD, 2.9]) had a statistically significant decrease compared with those in the control group (15.96 [SD, 3.4]) at post-procedure (P < .01). There was no statistically significant difference on blood pressure, heart rate, and Short-Form Health Survey at postangiography between the Chinese hand massage group and the control group. No adverse event was reported during the intervention period. Chinese hand massage effectively alleviated anxiety without any adverse effects among patients awaiting coronary angiography. Therefore, it might be recommended as a nonpharmacological nursing intervention. However, future study with a larger sample size is needed to further confirm the efficacy of Chinese hand massage intervention.

  11. Efficacy of stem cell in improvement of left ventricular function in acute myocardial infarction - MI3 Trial

    PubMed Central

    Nair, Velu; Madan, Hemant; Sofat, Sunil; Ganguli, Prosenjit; Jacob, M.J.; Datta, Rajat; Bharadwaj, Prashant; Sarkar, R.S.; Pandit, A.J.; Nityanand, Soniya; Goel, Pravin K.; Garg, Naveen; Gambhir, Sanjay; George, Paul V.; Chandy, Sunil; Mathews, Vikram; George, Oomen K.; Talwar, K.K.; Bahl, Ajay; Marwah, Neelam; Bhatacharya, Anish; Bhargava, Balram; Airan, Balram; Mohanty, Sujata; Patel, Chetan D.; Sharma, Alka; Bhatnagar, Shinjini; Mondal, A.; Jose, Jacob; Srivastava, A.

    2015-01-01

    Background & objectives: Acute myocardial infarction (AMI) is characterized by irreparable and irreversible loss of cardiac myocytes. Despite major advances in the management of AMI, a large number of patients are left with reduced left ventricular ejection fraction (LVEF), which is a major determinant of short and long term morbidity and mortality. A review of 33 randomized control trials has shown varying improvement in left ventricular (LV) function in patients receiving stem cells compared to standard medical therapy. Most trials had small sample size and were underpowered. This phase III prospective, open labelled, randomized multicenteric trial was undertaken to evaluate the efficacy in improving the LVEF over a period of six months, after injecting a predefined dose of 5-10 × 108 autologous mononuclear cells (MNC) by intra-coronary route, in patients, one to three weeks post ST elevation AMI, in addition to the standard medical therapy. Methods: In this phase III prospective, multicentric trial 250 patients with AMI were included and randomized into stem cell therapy (SCT) and non SCT groups. All patients were followed up for six months. Patients with AMI having left ventricular ejection fraction (LVEF) of 20-50 per cent were included and were randomized to receive intracoronary stem cell infusion after successfully completing percutaneous coronary intervention (PCI). Results: On intention-to-treat analysis the infusion of MNCs had no positive impact on LVEF improvement of ≥ 5 per cent. The improvement in LVEF after six months was 5.17 ± 8.90 per cent in non SCT group and 4.82 ± 10.32 per cent in SCT group. The adverse effects were comparable in both the groups. On post hoc analysis it was noted that the cell dose had a positive impact when infused in the dose of ≥ 5 × 108(n=71). This benefit was noted upto three weeks post AMI. There were 38 trial deviates in the SCT group which was a limitation of the study. Interpretation & conclusions: Infusion of stem cells was found to have no benefit in ST elevation AMI. However, the procedure was safe. A possible benefit was seen when the predefined cell dose was administered which was noted upto three weeks post AMI, but this was not significant and needs confirmation by larger trials. PMID:26354213

  12. A comparative analysis of noncontrast flow-spoiled versus contrast-enhanced magnetic resonance angiography for evaluation of peripheral arterial disease.

    PubMed

    Kassamali, Rahil Hussein; Hoey, Edward T D; Ganeshan, Arul; Littlehales, Tracey

    2013-01-01

    This feasibility study aimed to obtain initial data to assess the performance of a novel noncontrast spoiled magnetic resonance (MR) angiography technique (fresh-blood imaging [FBI]) compared to gadolinium-enhanced MR (Gd-MR) angiography for evaluation of the aorto-iliac and lower extremity arteries. Thirteen patients with suspected lower extremity arterial disease that had undergone Gd-MR angiography and FBI at the same session were randomly included in the study. FBI was performed using an ECG-gated ow-spoiled T2-weighted half-Fourier fast spin-echo sequence. For analysis, the aortoiliac and lower limb arteries were divided into 18 anatomical segments. Two blinded readers individually graded image quality of FBI and also assessed the presence and severity of any stenotic lesions. A similar analysis was performed for the Gd-MR angiography images. A total of 385 arterial segments were analyzed; 34 segments were excluded due to degraded image quality (1.3% of Gd- MR vs. 8% of FBI-MR angiography images). FBI-MR angiography had comparable accuracy to Gd-MR angiography for assessment of the above knee vessels with high kappa statistics (large arteries, 0.91; small arteries, 0.86) and high sensitivity (large arteries, 98.1%; small arteries, 88.6%) and specificity (large arteries, 97.2%; small arteries, 97.6%) using Gd-MR angiography as the gold standard. Initial results show good agreement between FBI-MR angiography and Gd-MR angiography in the diagnosis of peripheral arterial disease, making FBI a potential alternative in patients with renal impairment. FBI showed highest accuracy in the above knee vessels. Technological refinements are required to improve accuracy for assessing the calf and pedal vessels.

  13. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    PubMed

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure required to obtain clinically useful 3D rotational angiography. © 2018 by American Journal of Neuroradiology.

  14. The costs and effects of contrast-enhanced magnetic resonance angiography and digital substraction angiography on quality of life in patients with peripheral arterial disease.

    PubMed

    Bosma, Jan; Dijksman, Lea M; Lam, Kayan; Wisselink, Willem; van Swijndregt, Alexander D Montauban; Vahl, Anco

    2014-04-01

    Contrast-enhanced magnetic resonance angiography (MRA) and intra-arterial digital subtraction angiography (DSA) both have a high diagnostic performance in the imaging of peripheral arterial occlusive disease (PAOD). However, little is known about the effects of initial, preoperative imaging using MRA or DSA on quality of life (QoL) in relation to costs (cost-utility). To compare cost-utility of treatment strategies using either MRA or DSA as the principal imaging tool, related to QoL, in patients with PAOD. In a prospective subgroup analysis of patients randomized between MRA and DSA (n = 79) for preoperative imaging, QoL questionnaires (SF-36) were obtained at randomization and at 4-month follow-up. Cost-effectiveness from hospital perspective was subsequently compared between groups and the difference in gained or lost QoL per € spent assessed using bootstrap analysis. No difference in quality of life was found. A treatment trajectory employing MRA as the principal imaging modality was almost 20% cheaper, leading to a better cost-utility ratio in favor of MRA. A treatment plan for peripheral arterial occlusive disease employing MRA versus DSA as the principal imaging modality yields a better cost/QoL ratio for MRA.

  15. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial.

    PubMed

    Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W

    2016-11-26

    Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm 2 ), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm 2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm 2 (4·67-7·80) with IVUS guidance, and 5·49 mm 2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm 2 ; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. St Jude Medical. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial.

    PubMed

    Uretsky, Seth; Argulian, Edgar; Supariwala, Azhar; Agarwal, Shiv K; El-Hayek, Georges; Chavez, Patricia; Awan, Hira; Jagarlamudi, Ashadevi; Puppala, Siva P; Cohen, Randy; Rozanski, Alan

    2017-08-01

    Because the frequency of cardiac event rates is low among chest pain patients following either performance of coronary CT angiography (CCTA) or stress testing, there is a need to better assess how these tests influence the central management decisions that follow from cardiac testing. The present study was performed to assess the relative impact of CCTA vs stress testing on medical therapies and downstream resource utilization among patients admitted for the work-up of chest pain. The admitted patients were randomized in a 1:1 ratio to either cardiac imaging stress test or CCTA. Primary outcomes were time to discharge, change in medication usage, and frequency of downstream testing, cardiac interventions, and cardiovascular re-hospitalizations. We randomized 411 patients, 205 to stress testing, and 206 to CCTA. There were no differences in time to discharge or initiation of new cardiac medications at discharge. At 1 year follow-up, there was no difference in the number of patients who underwent cardiovascular downstream tests in the CCTA vs stress test patients (21% vs 15%, P = .1) or cardiovascular hospitalizations (14% vs 16%, P = .5). However, there was a higher frequency of invasive angiography in the CCTA group (11% vs 2%, P = .001) and percutaneous coronary interventions (6% vs 0%, P < .001). Randomization of hospitalized patients admitted for chest pain work-up to either CCTA or to stress testing resulted in similar discharge times, change in medical therapies at discharge, frequency of downstream noninvasive testing, and repeat hospitalizations. However, a higher frequency of invasive coronary angiography and revascularization procedures were performed in the CCTA arm. (ClinicalTrials.gov number, NCT01604655.).

  17. Use of Coronary Computed Tomographic Angiography to Guide Management of Patients With Coronary Disease

    PubMed Central

    Williams, Michelle C.; Hunter, Amanda; Shah, Anoop S.V.; Assi, Valentina; Lewis, Stephanie; Smith, Joel; Berry, Colin; Boon, Nicholas A.; Clark, Elizabeth; Flather, Marcus; Forbes, John; McLean, Scott; Roditi, Giles; van Beek, Edwin J.R.; Timmis, Adam D.; Newby, David E.

    2016-01-01

    Background In a prospective, multicenter, randomized controlled trial, 4,146 patients were randomized to receive standard care or standard care plus coronary computed tomography angiography (CCTA). Objectives The purpose of this study was to explore the consequences of CCTA-assisted diagnosis on invasive coronary angiography, preventive treatments, and clinical outcomes. Methods In post hoc analyses, we assessed changes in invasive coronary angiography, preventive treatments, and clinical outcomes using national electronic health records. Results Despite similar overall rates (409 vs. 401; p = 0.451), invasive angiography was less likely to demonstrate normal coronary arteries (20 vs. 56; hazard ratios [HRs]: 0.39 [95% confidence interval (CI): 0.23 to 0.68]; p < 0.001) but more likely to show obstructive coronary artery disease (283 vs. 230; HR: 1.29 [95% CI: 1.08 to 1.55]; p = 0.005) in those allocated to CCTA. More preventive therapies (283 vs. 74; HR: 4.03 [95% CI: 3.12 to 5.20]; p < 0.001) were initiated after CCTA, with each drug commencing at a median of 48 to 52 days after clinic attendance. From the median time for preventive therapy initiation (50 days), fatal and nonfatal myocardial infarction was halved in patients allocated to CCTA compared with those assigned to standard care (17 vs. 34; HR: 0.50 [95% CI: 0.28 to 0.88]; p = 0.020). Cumulative 6-month costs were slightly higher with CCTA: difference $462 (95% CI: $303 to $621). Conclusions In patients with suspected angina due to coronary heart disease, CCTA leads to more appropriate use of invasive angiography and alterations in preventive therapies that were associated with a halving of fatal and non-fatal myocardial infarction. (Scottish COmputed Tomography of the HEART Trial [SCOT-HEART]; NCT01149590) PMID:27081014

  18. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    PubMed

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  19. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography

    PubMed Central

    Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870

  20. A cost-utility analysis of the use of preoperative computed tomographic angiography in abdomen-based perforator flap breast reconstruction.

    PubMed

    Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei

    2015-04-01

    Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.

  1. Stored-fluorography mode reduces radiation dose during cardiac catheterization measured with OSLD dosimeter

    NASA Astrophysics Data System (ADS)

    Ting, Chien-Yi; Chen, Zhih-Cherng; Tang, Kuo-Ting; Liu, Wei-Chung; Lin, Chun-Chih; Wang, Hsin-Ell

    2015-12-01

    Coronary angiogram is an imperative tool for diagnosis of coronary artery diseases, in which cine-angiography is a commonly used method. Although the angiography proceeds under radiation, the potential risk of radiation exposure for both the patients and the operators was seldom noticed. In this study, the absorbed radiation dose in stored-fluorography mode was compared with that in cine-angiography mode by using optically simulated luminescent dosimeters to realize their effects on radiation dose. Patients received coronary angiogram via radial artery approach were randomized into the stored-fluorography group (N=30) or the cine-angiography group (N=30). The excluded criteria were: 1. women at pregnancy or on breast feeding, 2. chronic kidney diseases with glomerular filtration rate less than 60 mL/min. During the coronary angiogram, absorbed dose of the patients and the operator radiation exposure was measured with optically simulated luminescent dosimeter (OSLD). The absorbed dose of the patients in the stored-fluorography group (3.13±0.25 mGy) was apparently lower than that in the cine-angiography group (65.57±5.37 mGy; P<0.001). For the operator, a statistical difference (P<0.001) was also found between the stored-fluorography group (0.09163 μGy) and the cine-angiography (0.6519μGy). Compared with traditional cine-angiography mode, the stored-fluorography mode can apparently reduce radiation exposure of the patients and the operator in coronary angiogram.

  2. Effect of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease undergoing coronary angiography.

    PubMed

    Deftereos, Spyridon; Giannopoulos, Georgios; Kossyvakis, Charalampos; Raisakis, Konstantinos; Kaoukis, Andreas; Driva, Metaxia; Ntzouvara, Olga; Panagopoulou, Vasiliki; Rentoukas, Ilias; Nikas, Dimitrios J; Pyrgakis, Vlasios; Alpert, Martin A

    2009-09-01

    The effects of radiographic contrast media on markers of complement activation and apoptosis in patients with chronic coronary artery disease (CAD) are unknown. The purpose of this study was to assess the comparative effects of ionic high-osmolar and non-ionic iso-osmolar radiographic contrast media on plasma markers of complement activation and apoptosis in patients with chronic CAD undergoing coronary angiography. Forty-four patients undergoing coronary angiography for chronic CAD were randomly assigned to receive the ionic high-osmolar radiographic contrast agent diatrizoate (Group A), or the non-ionic iso-osmolar contrast agent iodixanol (Group B) during angiography. Complement component 5 (C5a) and apoptotic markers sFas and sFasL were measured just prior to angiography and 1 hour after completion of angiography. Comparison of mean pre- and post-angiography plasma marker levels showed significantly greater increases in plasma levels in Group A than in Group B of C5a (29.30 +/- 5.45 ng/ml for Group A and 0.47 +/- 0.70 ng/ml for Group B (p < 0.00001), sFas (2.36 +/- 1.63 ng/ml for Group A and 0.23 +/- 0.90 ng/ml for Group B (p < 0.00001) and sFasL (14.00 +/- 5.41 pg/ml for Group A and 0.01 +/- 1.00 pg/ml for Group B (p < 0.00001). The results suggest that in patients with chronic CAD, the use of ionic high-osmolar radiographic contrast media during coronary angiography is associated with a more robust inflammatory and apoptotic milieu than that associated with the use of non-ionic iso-osmolar radiographic contrast media.

  3. Efficacy of Atorvastatin in Prevention of Contrast-induced Nephropathy in High-risk Patients Undergoing Angiography: A Double-blind Randomized Controlled Trial.

    PubMed

    Syed, Maaz Hussain; Khandelwal, Prakash Narayan; Thawani, Vijay R; Katare, S S

    2017-01-01

    To evaluate the efficacy and safety of atorvastatin (ATN) 80 mg in the prevention of contrast medium- induced nephropathy (CIN) in high risk patients undergoing angiograph. This was a prospective, double-blind, two-arm, parallel group RCT. A total of 216 patients undergoing coronary angiography were screened, and 188 eligible patients were randomized to two treatment arms. Patients in Group A received tablet N-acetylcysteine (NAC) 1200 mg once daily, and patients in Group B received tablet atorvastatin 80 mg + NAC 1200 mg once daily, for 3 days before, and 2 days after angiography. A total of 160 patients completed the trial. Postprocedure, nine and two CIN cases were found in Group A and B, respectively. The mean change in serum creatinine was 0.086 ± 0.168 in Group A and 0.021 ± 0.083 in Group B, which was statistically significant ( P = 0.0289). Postprocedure, the estimated glomerular filteration rate was reduced by 19.52 in Group A and 13.55 in Group B ( P = 0.003). This trial indicates the positive role of statins in preventive strategy against CIN along with NAC.

  4. Efficacy of Atorvastatin in Prevention of Contrast-induced Nephropathy in High-risk Patients Undergoing Angiography: A Double-blind Randomized Controlled Trial

    PubMed Central

    Syed, Maaz Hussain; Khandelwal, Prakash Narayan; Thawani, Vijay R.; Katare, S. S.

    2017-01-01

    Objective: To evaluate the efficacy and safety of atorvastatin (ATN) 80 mg in the prevention of contrast medium- induced nephropathy (CIN) in high risk patients undergoing angiograph. Materials and Methods: This was a prospective, double-blind, two-arm, parallel group RCT. A total of 216 patients undergoing coronary angiography were screened, and 188 eligible patients were randomized to two treatment arms. Patients in Group A received tablet N-acetylcysteine (NAC) 1200 mg once daily, and patients in Group B received tablet atorvastatin 80 mg + NAC 1200 mg once daily, for 3 days before, and 2 days after angiography. Results: A total of 160 patients completed the trial. Postprocedure, nine and two CIN cases were found in Group A and B, respectively. The mean change in serum creatinine was 0.086 ± 0.168 in Group A and 0.021 ± 0.083 in Group B, which was statistically significant (P = 0.0289). Postprocedure, the estimated glomerular filteration rate was reduced by 19.52 in Group A and 13.55 in Group B (P = 0.003). Conclusion: This trial indicates the positive role of statins in preventive strategy against CIN along with NAC. PMID:28706398

  5. High-volume forced diuresis with matched hydration using the RenalGuard System to prevent contrast-induced nephropathy: A meta-analysis of randomized trials.

    PubMed

    Shah, Rahman; Wood, Sarah J; Khan, Sajjad A; Chaudhry, Amina; Rehan Khan, M; Morsy, Mohamed S

    2017-12-01

    Contrast-induced nephropathy (CIN) is a well-recognized complication of coronary angiography that is associated with poor outcomes. Several small randomized controlled trials (RCTs) have recently shown that in patients with chronic kidney disease (CKD), furosemide-induced forced diuresis with matched hydration using the RenalGuard system can prevent its occurrence. However, individual studies have been underpowered and thus cannot show significant differences in major clinical endpoints. Forced diuresis with matched hydration using the RenalGuard system improves clinical outcomes in patients undergoing coronary angiography. Scientific databases and websites were searched for relevant RCTs. The pooled risk ratios were calculated using random-effects models. The primary endpoint was CIN, and the secondary endpoints were major adverse clinical events (MACEs) and the need for renal replacement therapy. Data from 3 trials including 586 patients were analyzed. High-volume forced diuresis with matched hydration using the RenalGuard system decreased risk of CIN by 60% (risk ratio: 0.40, 95% confidence interval: 0.25 to 0.65, P < 0.001), MACE rate by 59%, and the need for renal replacement therapy by 78%, compared with the standard of care. In patients with CKD undergoing coronary angiography, high-volume forced diuresis with matched hydration using the RenalGuard system significantly reduces the risk of CIN, MACE rate, and the need for renal replacement therapy. Larger RCTs with sufficient power are needed to confirm these findings. © 2017 Wiley Periodicals, Inc.

  6. Rationale and design of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary heart disease 2 trial (CE-MARC 2): A prospective, multicenter, randomized trial of diagnostic strategies in suspected coronary heart disease

    PubMed Central

    Ripley, David P.; Brown, Julia M.; Everett, Colin C.; Bijsterveld, Petra; Walker, Simon; Sculpher, Mark; McCann, Gerry P.; Berry, Colin; Plein, Sven; Greenwood, John P.

    2015-01-01

    Background A number of investigative strategies exist for the diagnosis of coronary heart disease (CHD). Despite the widespread availability of noninvasive imaging, invasive angiography is commonly used early in the diagnostic pathway. Consequently, approximately 60% of angiograms reveal no evidence of obstructive coronary disease. Reducing unnecessary angiography has potential financial savings and avoids exposing the patient to unnecessary risk. There are no large-scale comparative effectiveness trials of the different diagnostic strategies recommended in international guidelines and none that have evaluated the safety and efficacy of cardiovascular magnetic resonance. Trial Design CE-MARC 2 is a prospective, multicenter, 3-arm parallel group, randomized controlled trial of patients with suspected CHD (pretest likelihood 10%-90%) requiring further investigation. A total of 1,200 patients will be randomized on a 2:2:1 basis to receive 3.0-T cardiovascular magnetic resonance–guided care, single-photon emission computed tomography–guided care (according to American College of Cardiology/American Heart Association appropriate-use criteria), or National Institute for Health and Care Excellence guidelines–based management. The primary (efficacy) end point is the occurrence of unnecessary angiography as defined by a normal (>0.8) invasive fractional flow reserve. Safety of each strategy will be assessed by 3-year major adverse cardiovascular event rates. Cost-effectiveness and health-related quality-of-life measures will be performed. Conclusions The CE-MARC 2 trial will provide comparative efficacy and safety evidence for 3 different strategies of investigating patients with suspected CHD, with the intension of reducing unnecessary invasive angiography rates. Evaluation of these management strategies has the potential to improve patient care, health-related quality of life, and the cost-effectiveness of CHD investigation. PMID:25497243

  7. Short-Term High-Dose Vitamin E to Prevent Contrast Medium-Induced Acute Kidney Injury in Patients With Chronic Kidney Disease Undergoing Elective Coronary Angiography: A Randomized Placebo-Controlled Trial.

    PubMed

    Rezaei, Yousef; Khademvatani, Kamal; Rahimi, Behzad; Khoshfetrat, Mehran; Arjmand, Nasim; Seyyed-Mohammadzad, Mir-Hossein

    2016-03-15

    Contrast medium-induced acute kidney injury (CIAKI) is a leading cause of acquired renal impairment. The effects of antioxidants have been conflicting regarding the prevention of CIAKI. We performed a study of vitamin E use to decrease CIAKI in patients undergoing elective coronary angiography. In a placebo-controlled randomized trial at 2 centers in Iran, 300 patients with chronic kidney disease-defined as estimated glomerular filtration rate <60 mL/min per 1.73 m(2)-were randomized 1:1 to receive 0.9% saline infusion 12 hours prior to and after intervention combined with 600 mg vitamin E 12 hours before plus 400 mg vitamin E 2 hours before coronary angiography or to receive placebo. The primary end point was the development of CIAKI, defined as an increase ≥0.5 mg/dL or ≥25% in serum creatinine that peaked within 72 hours. Based on an intention-to-treat analysis, CIAKI developed in 10 (6.7%) and 21 (14.1%) patients in the vitamin E and placebo groups, respectively (P=0.037). Change in white blood cell count from baseline to peak value was greater in the vitamin E group compared with the placebo group (-500 [-1500 to 200] versus 100 [-900 to 600]×10(3)/mL, P=0.001). In multivariate analysis, vitamin E (odds ratio 0.408, 95% CI 0.170-0.982, P=0.045) and baseline Mehran score (odds ratio 1.257, 95% CI 1.007-1.569; P=0.043) predicted CIAKI. Prophylactic short-term high-dose vitamin E combined with 0.9% saline infusion is superior to placebo for prevention of CIAKI in patients undergoing elective coronary angiography. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT02070679. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  8. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield.

    PubMed

    Politi, Luigi; Biondi-Zoccai, Giuseppe; Nocetti, Luca; Costi, Tiziana; Monopoli, Daniel; Rossi, Rosario; Sgura, Fabio; Modena, Maria Grazia; Sangiorgi, Giuseppe M

    2012-01-01

    Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans. Sixty consecutive patients undergoing coronary angiography by radial approach were randomized 1:1 to Radpad use versus no radiation shield protection. The sterile shield was placed around the area of right radial artery sheath insertion and extended medially to the patient trunk. All diagnostic procedures were performed by the same operator to reduce variability in radiation absorption. Radiation exposure was measured blindly using thermoluminescence dosimeters positioned at the operator's chest, left eye, left wrist, and thyroid. Despite similar fluoroscopy time (3.52 ± 2.71 min vs. 3.46 ± 2.77 min, P = 0.898) and total examination dose (50.5 ± 30.7 vs. 45.8 ± 18.0 Gycm(2), P = 0.231), the mean total radiation exposure to the operator was significantly lower when Radpad was utilized (282.8 ± 32.55 μSv vs. 367.8 ± 105.4 μSv, P < 0.0001) corresponding to a 23% total reduction. Moreover, mean radiation exposure was lower with Radpad utilization at all body locations ranging from 13 to 34% reduction. This first-in-men randomized trial demonstrates that Radpad significantly reduces occupational radiation exposure during coronary angiography performed through right radial artery access. Copyright © 2011 Wiley Periodicals, Inc.

  9. The effect of reflexotherapy and massage therapy on vital signs and stress before coronary angiography: An open-label clinical trial.

    PubMed

    Khaledifar, Ali; Nasiri, Marzeih; Khaledifar, Borzoo; Khaledifar, Arsalan; Mokhtari, Ali

    2017-03-01

    Complementary medicine interventions are now successfully used to reduce stress as well as to stabilize hemodynamic indices within different procedures. The present study aimed to examine the effect of massage therapy and reflexotherapy on reducing stress in patients before coronary angiography. In this open-label clinical trial, 75 consecutive patients who were candidate for coronary angiography were randomly assigned to receive reflexotherapy (n = 25), or massage therapy (n = 25), or routine care (n = 25) before angiography. The Spielberger State-Trait Anxiety Inventory was used to determine the stress level of patients before and after interventions and vital signs were also measured. Improvement in diastolic blood pressure, heart rate, and respiratory rate was shown in the reflexotherapy group, and similar effects were observed following other interventions including massage therapy and routine resting program. In subjects who received reflexotherapy the level of stress decreased slightly compared with the other two groups. However, following interventions the level of stress in reflexotherapy group was shown to be lower than other study groups. Reflexotherapy before coronary angiography can help to stabilize vital sign as well as reduce the level of stress. The effect of massage therapy was limited to reducing stress.

  10. Coronary Computed Tomography Angiography vs Functional Stress Testing for Patients With Suspected Coronary Artery Disease: A Systematic Review and Meta-analysis.

    PubMed

    Foy, Andrew J; Dhruva, Sanket S; Peterson, Brandon; Mandrola, John M; Morgan, Daniel J; Redberg, Rita F

    2017-11-01

    Coronary computed tomography angiography (CCTA) is a new approach for the diagnosis of anatomical coronary artery disease (CAD), but it is unclear how CCTA performs compared with the standard approach of functional stress testing. To compare the clinical effectiveness of CCTA with that of functional stress testing for patients with suspected CAD. A systematic literature search was conducted in PubMed and MEDLINE for English-language randomized clinical trials of CCTA published from January 1, 2000, to July 10, 2016. Researchers selected randomized clinical trials that compared a primary strategy of CCTA with that of functional stress testing for patients with suspected CAD and reported data on patient clinical events and changes in therapy. Two reviewers independently extracted data from and assessed the quality of the trials. This analysis followed the PRISMA statement for reporting systematic reviews and meta-analyses and used the Cochrane Collaboration's tool for assessing risk of bias in randomized trials. The Mantel-Haenszel method was used to conduct the primary analysis. Summary relative risks were calculated with a random-effects model. The outcomes of interest were all-cause mortality, cardiac hospitalization, myocardial infarction, invasive coronary angiography, coronary revascularization, new CAD diagnoses, and change in prescription for aspirin and statins. Thirteen trials were included, with 10 315 patients in the CCTA arm and 9777 patients in the functional stress testing arm who were followed up for a mean duration of 18 months. There were no statistically significant differences between CCTA and functional stress testing in death (1.0% vs 1.1%; risk ratio [RR], 0.93; 95% CI, 0.71-1.21) or cardiac hospitalization (2.7% vs 2.7%; RR, 0.98; 95% CI, 0.79-1.21), but CCTA was associated with a reduction in the incidence of myocardial infarction (0.7% vs 1.1%; RR, 0.71; 95% CI, 0.53-0.96). Patients undergoing CCTA were significantly more likely to undergo invasive coronary angiography (11.7% vs 9.1%; RR, 1.33; 95% CI, 1.12-1.59) and revascularization (7.2% vs 4.5%; RR, 1.86; 95% CI, 1.43-2.43). They were also more likely to receive a diagnosis of new CAD and to have initiated aspirin or statin therapy. Compared with functional stress testing, CCTA is associated with a reduced incidence of myocardial infarction but an increased incidence of invasive coronary angiography, revascularization, CAD diagnoses, and new prescriptions for aspirin and statins. Despite these differences, CCTA is not associated with a reduction in mortality or cardiac hospitalizations.

  11. Contrast media use in patients with chronic kidney disease undergoing coronary angiography: A systematic review and meta-analysis of randomized trials.

    PubMed

    Pandya, Bhavi; Chalhoub, Jean M; Parikh, Valay; Gaddam, Sainath; Spagnola, Jonathan; El-Sayegh, Suzanne; Bogin, Marc; Kandov, Ruben; Lafferty, James; Bangalore, Sripal

    2017-02-01

    Patients with chronic kidney disease (CKD) undergoing coronary angiography (CA), adequate hydration and minimizing volume of contrast media (CM) are class 1b recommendations for preventing contrast induced nephropathy (CIN). Current data are insufficient to justify specific recommendations about isoosmolar vs. low-osmolar contrast media by the ACCF/AHA/SCAI guidelines. Randomized trials comparing IOCM to LOCM in CKD stage 3 and above patients undergoing CA, and reporting incidence of CIN (defined by a rise in creatinine of 25% from baseline) were included in the analysis. The secondary outcome of the study was the incidence of serum creatinine increase by >1mg/dl. A total of 2839 patients were included in 10 trials, in which 1430 patients received IOCM and 1393 received LOCM. When compared to LOCM, IOCM was not associated with significant benefit in preventing CIN (OR=0.72, [CI: 0.50-1.04], P=0.08, I2=59%). Subgroup analysis revealed non-significant difference in incidence of CIN based on baseline use of N-acetylcystine (NAC), diabetes status, ejection fraction, and whether percutaneous coronary intervention vs coronary angiography alone was performed. The difference between IOCM and LOCM was further attenuated when restricted to studies with larger sample size (>250 patients) (OR=0.93; [CI: 0.66-1.30]) or when compared with non-ionic LOCM (OR=0.79, [CI: 0.52-1.21]). In patients with CKD stage 3 and above undergoing coronary angiography, use of IOCM showed overall non-significant difference in incidence of CIN compared to LOCM. The difference was further attenuated when IOCM was compared with non-ionic LOCM. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Timing of angiography with a routine invasive strategy and long-term outcomes in non-ST-segment elevation acute coronary syndrome: a collaborative analysis of individual patient data from the FRISC II (Fragmin and Fast Revascularization During Instability in Coronary Artery Disease), ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes), and RITA-3 (Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction) Trials.

    PubMed

    Damman, Peter; van Geloven, Nan; Wallentin, Lars; Lagerqvist, Bo; Fox, Keith A A; Clayton, Tim; Pocock, Stuart J; Hirsch, Alexander; Windhausen, Fons; Tijssen, Jan G P; de Winter, Robbert J

    2012-02-01

    This study sought to investigate long-term outcomes after early or delayed angiography in patients with non-ST-segment elevation acute coronary syndrome (nSTE-ACS) undergoing a routine invasive management. The optimal timing of angiography in patients with nSTE-ACS is currently a topic for debate. Long-term follow-up after early (within 2 days) angiography versus delayed (within 3 to 5 days) angiography was investigated in the FRISC-II (Fragmin and Fast Revascularization During Instability in Coronary Artery Disease), ICTUS (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes), and RITA-3 (Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction) (FIR) nSTE-ACS patient-pooled database. The main outcome was cardiovascular death or myocardial infarction up to 5-year follow-up. Hazard ratios (HR) were calculated with Cox regression models. Adjustments were made for the FIR risk score, study, and the propensity of receiving early angiography using inverse probability weighting. Of 2,721 patients originally randomized to the routine invasive arm, consisting of routine angiography and subsequent revascularization if suitable, 975 underwent early angiography and 1,141 delayed angiography. No difference was observed in 5-year cardiovascular death or myocardial infarction in unadjusted (HR: 1.06, 95% confidence interval [CI]: 0.79 to 1.42, p=0.61) and adjusted (HR: 0.93, 95% CI: 0.75 to 1.16, p=0.54) Cox regression models. In the FIR database of patients presenting with nSTE-ACS, the timing of angiography was not related to long-term cardiovascular mortality or myocardial infarction. (Invasive Versus Conservative Treatment in Unstable Coronary Syndromes [ICTUS]; ISRCTN82153174. Intervention Versus Conservative Treatment Strategy in Patients With Unstable Angina or Non-ST Elevation Myocardial Infarction [the Third Randomised Intervention Treatment of Angina Trials (RITA-3)]; ISRCTN07752711). Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    PubMed

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P < 0.0001). Mean perfusion impairment was less in the Allgöwer-Donati cohort (12.8, SD = 9) compared with that in the vertical mattress cohort (23.4, SD = 14; P = 0.03). One patient in each cohort experienced a wound complication. The Allgöwer-Donati suture technique offers improved incision perfusion compared with vertical mattress closure after open reduction internal fixation of ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  14. NOR-SASS (Norwegian Sonothrombolysis in Acute Stroke Study): Randomized Controlled Contrast-Enhanced Sonothrombolysis in an Unselected Acute Ischemic Stroke Population.

    PubMed

    Nacu, Aliona; Kvistad, Christopher E; Naess, Halvor; Øygarden, Halvor; Logallo, Nicola; Assmus, Jörg; Waje-Andreassen, Ulrike; Kurz, Kathinka D; Neckelmann, Gesche; Thomassen, Lars

    2017-02-01

    The NOR-SASS (Norwegian Sonothrombolysis in Acute Stroke Study) aimed to assess effect and safety of contrast-enhanced ultrasound treatment in an unselected acute ischemic stroke population. Patients treated with intravenous thrombolysis within 4.5 hours after symptom onset were randomized 1:1 to either contrast-enhanced sonothrombolysis (CEST) or sham CEST. A visible arterial occlusion on baseline computed tomography angiography was not a prerequisite for inclusion. Pulse-wave 2 MHz ultrasound was given for 1 hour and contrast (SonoVue) as an infusion for ≈30 minutes. Magnetic resonance imaging and angiography were performed after 24 to 36 hours. Primary study end points were neurological improvement at 24 hours defined as National Institutes of Health Stroke Scale score 0 or reduction of ≥4 National Institutes of Health Stroke Scale points compared with baseline National Institutes of Health Stroke Scale and favorable functional outcome at 90 days defined as modified Rankin scale score 0 to 1. A total of 183 patients were randomly assigned to either CEST (93 patient) or sham CEST (90 patients). The rates of symptomatic intracerebral hemorrhage, asymptomatic intracerebral hemorrhage, or mortality were not increased in the CEST group. Neurological improvement at 24 hours and functional outcome at 90 days was similar in the 2 groups both in the intention-to-treat analysis and in the per-protocol analysis. CEST is safe among unselected ischemic stroke patients with or without a visible occlusion on computed tomography angiography and with varying grades of clinical severity. There was, however, statistically no significant clinical effect of sonothrombolysis in this prematurely stopped trial. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01949961. © 2016 The Authors.

  15. Features of the normal choriocapillaris with OCT-angiography: Density estimation and textural properties.

    PubMed

    Montesano, Giovanni; Allegrini, Davide; Colombo, Leonardo; Rossetti, Luca M; Pece, Alfredo

    2017-01-01

    The main objective of our work is to perform an in depth analysis of the structural features of normal choriocapillaris imaged with OCT Angiography. Specifically, we provide an optimal radius for a circular Region of Interest (ROI) to obtain a stable estimate of the subfoveal choriocapillaris density and characterize its textural properties using Markov Random Fields. On each binarized image of the choriocapillaris OCT Angiography we performed simulated measurements of the subfoveal choriocapillaris densities with circular Regions of Interest (ROIs) of different radii and with small random displacements from the center of the Foveal Avascular Zone (FAZ). We then calculated the variability of the density measure with different ROI radii. We then characterized the textural features of choriocapillaris binary images by estimating the parameters of an Ising model. For each image we calculated the Optimal Radius (OR) as the minimum ROI radius required to obtain a standard deviation in the simulation below 0.01. The density measured with the individual OR was 0.52 ± 0.07 (mean ± STD). Similar density values (0.51 ± 0.07) were obtained using a fixed ROI radius of 450 μm. The Ising model yielded two parameter estimates (β = 0.34 ± 0.03; γ = 0.003 ± 0.012; mean ± STD), characterizing pixel clustering and white pixel density respectively. Using the estimated parameters to synthetize new random textures via simulation we obtained a good reproduction of the original choriocapillaris structural features and density. In conclusion, we developed an extensive characterization of the normal subfoveal choriocapillaris that might be used for flow analysis and applied to the investigation pathological alterations.

  16. Effectiveness of Fluorography versus Cineangiography at Reducing Radiation Exposure During Diagnostic Coronary Angiography

    PubMed Central

    Shah, Binita; Mai, Xingchen; Tummala, Lakshmi; Kliger, Chad; Bangalore, Sripal; Miller, Louis H.; Sedlis, Steven P.; Feit, Frederick; Liou, Michael; Attubato, Michael; Coppola, John; Slater, James

    2014-01-01

    Coronary angiography is the gold standard for defining obstructive coronary disease. However, radiation exposure remains an unwanted hazard. Patients referred for coronary angiography with abdominal circumference <45 inches and glomerular filtration rate >60mL/min were randomized to the Fluorography (n=25) or Cineangiography (n=25) group. Patients in the Fluorography group underwent coronary angiography using retrospectively-stored fluorography with repeat injection under cineangiography only when needed for better resolution per operator’s discretion. Patients in the Cineangiography group underwent coronary angiography using routine cineangiography. The primary endpoint was patient radiation exposure measured by radiochromic film. Secondary endpoints included the radiation output measurement of kerma-area product (KAP) and air kerma at the interventional reference point (Ka,r), and operator radiation exposure measured by dosimeter. Patient radiation exposure (158.2mGy [76.5–210.2] vs 272.5mGy [163.3–314.0], p=0.001), KAP (1323μGy m2 [826–1765] vs 3451μGy m2 [2464–4818], p<0.001), and Ka,r (175 mGy [112–252] vs 558 mGy [313–621], p<0.001)was significantly lower in the Fluorography compared with Cineangiography group (42%, 62%, and 69% relative reduction, respectively). Operator radiation exposure trended in the same direction though statistically non-significant (Fluorography 2.35 μGy [1.24–6.30] vs Cineangiography 5.03μGy [2.48–7.80], p=0.059). In conclusion, the use of fluorography in a select group of patients during coronary angiography with repeat injection under cineangiography only when needed was efficacious at reducing patient radiation exposure. PMID:24513469

  17. Recent Scientific Evidence and Technical Developments in Cardiovascular Computed Tomography.

    PubMed

    Marcus, Roy; Ruff, Christer; Burgstahler, Christof; Notohamiprodjo, Mike; Nikolaou, Konstantin; Geisler, Tobias; Schroeder, Stephen; Bamberg, Fabian

    2016-05-01

    In recent years, coronary computed tomography angiography has become an increasingly safe and noninvasive modality for the evaluation of the anatomical structure of the coronary artery tree with diagnostic benefits especially in patients with a low-to-intermediate pretest probability of disease. Currently, increasing evidence from large randomized diagnostic trials is accumulating on the diagnostic impact of computed tomography angiography for the management of patients with acute and stable chest pain syndrome. At the same time, technical advances have substantially reduced adverse effects and limiting factors, such as radiation exposure, the amount of iodinated contrast agent, and scanning time, rendering the technique appropriate for broader clinical applications. In this work, we review the latest developments in computed tomography technology and describe the scientific evidence on the use of cardiac computed tomography angiography to evaluate patients with acute and stable chest pain syndrome. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.

    PubMed

    Lee, Seung-Yul; Kim, Jung-Sun; Yoon, Hyuck-Jun; Hur, Seung-Ho; Lee, Sang-Gon; Kim, Jin Won; Hong, Young Joon; Kim, Ki-Seok; Choi, So-Yeon; Shin, Dong-Ho; Nam, Chung-Mo; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2018-02-09

    This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80). OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with favorable early strut coverage (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of The Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus-eluting Stents Versus Biolimus A9-eluting Stents [DETECT-OCT]; NCT01752894). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Does ascorbic acid protect against contrast-induced acute kidney injury in patients undergoing coronary angiography: a systematic review with meta-analysis of randomized, controlled trials.

    PubMed

    Sadat, Umar; Usman, Ammara; Gillard, Jonathan H; Boyle, Jonathan R

    2013-12-10

    This study sought to perform a systematic review with meta-analysis of randomized controlled trials comparing the use of ascorbic acid with placebo or other treatment options for the treatment of contrast induced-acute kidney injury (CI-AKI) in patients undergoing coronary angiography. CI-AKI remains the most widely discussed and debated topic in cardiovascular medicine, with its incidence increasing due to an increasing number of contrast media-enhanced radiological procedures being performed. MEDLINE, Embase, and Cochrane central databases were searched from inception to May 2013, without language restrictions. For a study to be selected, it had to report the incidence of CI-AKI as an outcome measure. Studies were excluded if at least 1 study arm did not have ascorbic acid administered alone or with saline solution hydration. Data were extracted by 1 author, and random checks were made by another author. Nine randomized, controlled trials reported data on the incidence of CI-AKI in 1,536 patients who had completed the trial and were included in the final analysis. Patients receiving ascorbic acid had 33% less risk of CI-AKI compared with patients receiving placebo or an alternate pharmacological treatment (risk ratio by random-effects model: 0.672; 95% confidence interval, 0.466 to 0.969; p = 0.034). Ascorbic acid provides effective nephroprotection against CI-AKI and may form a part of effective prophylactic pharmacological regimens. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Outcomes after coronary computed tomography angiography in the emergency department: a systematic review and meta-analysis of randomized, controlled trials.

    PubMed

    Hulten, Edward; Pickett, Christopher; Bittencourt, Marcio Sommer; Villines, Todd C; Petrillo, Sara; Di Carli, Marcelo F; Blankstein, Ron

    2013-02-26

    The aim of the study was to systematically review and perform a meta-analysis of randomized, controlled trials of coronary computed tomography angiography (CCTA) versus usual care (UC) triage of acute chest pain in the emergency department (ED). CCTA allows rapid evaluation of patients presenting to the ED with acute chest pain syndromes; however, the impact of such testing on patient management and downstream testing has emerged as a concern. We systematically searched for randomized, controlled trials of CCTA in the ED and performed a meta-analysis of clinical outcomes. Four randomized, controlled trials were included, with 1,869 patients undergoing CCTA and 1,397 undergoing UC. There were no deaths and no difference in the incidence of myocardial infarction, post-discharge ED visits, or rehospitalizations. Four studies reported decreased length of stay with CCTA and 3 reported cost savings; 8.4% of patients undergoing CCTA versus 6.3% of those receiving UC underwent invasive coronary angiography (ICA), whereas 4.6% of patients undergoing CCTA versus 2.6% of those receiving UC underwent coronary revascularization. The odds ratio of ICA for CCTA patients versus UC patients was 1.36 (95% confidence interval [CI]: 1.03 to 1.80, p = 0.030), and for revascularization, it was 1.81 (95% CI: 1.20 to 2.72, p = 0.004). The absolute increase in ICA after CCTA was 21 per 1,000 CCTA patients (95% CI: 1.8 to 44.9), and the number needed to scan was 48. The absolute increase in revascularization after CCTA was 20 per 1,000 patients (95% CI: 5.0 to 41.4); the number needed to scan was 50. Both percutaneous coronary intervention and coronary artery bypass graft surgery independently contributed to the significant increase in revascularization. Compared with UC, the use of CCTA in the ED is associated with decreased ED cost and length of stay but increased ICA and revascularization. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. OCT methods for capillary velocimetry

    PubMed Central

    Srinivasan, Vivek J.; Radhakrishnan, Harsha; Lo, Eng H.; Mandeville, Emiri T.; Jiang, James Y.; Barry, Scott; Cable, Alex E.

    2012-01-01

    To date, two main categories of OCT techniques have been described for imaging hemodynamics: Doppler OCT and OCT angiography. Doppler OCT can measure axial velocity profiles and flow in arteries and veins, while OCT angiography can determine vascular morphology, tone, and presence or absence of red blood cell (RBC) perfusion. However, neither method can quantify RBC velocity in capillaries, where RBC flow is typically transverse to the probe beam and single-file. Here, we describe new methods that potentially address these limitations. Firstly, we describe a complex-valued OCT signal in terms of a static scattering component, dynamic scattering component, and noise. Secondly, we propose that the time scale of random fluctuations in the dynamic scattering component are related to red blood cell velocity. Analysis was performed along the slow axis of repeated B-scans to parallelize measurements. We correlate our purported velocity measurements against two-photon microscopy measurements of RBC velocity, and investigate changes during hypercapnia. Finally, we image the ischemic stroke penumbra during distal middle cerebral artery occlusion (dMCAO), where OCT velocimetry methods provide additional insight that is not afforded by either Doppler OCT or OCT angiography. PMID:22435106

  2. Preventive effect of pretreatment with intravenous nicorandil on contrast-induced nephropathy in patients with renal dysfunction undergoing coronary angiography (PRINCIPLE Study).

    PubMed

    Ko, Young-Guk; Lee, Byoung-Kwon; Kang, Woong Chol; Moon, Jae-Youn; Cho, Yun Hyeong; Choi, Seong Hun; Hong, Myeong-Ki; Jang, Yangsoo; Kim, Jong-Youn; Min, Pil-Ki; Kwon, Hyuck-Moon

    2013-07-01

    To investigate the effect of pretreatment with intravenous nicorandil on the incidence of contrast-induced nephropathy (CIN) in patients with renal dysfunction undergoing coronary angiography. This randomized controlled multicenter study enrolled a total of 166 patients (nicorandil n=81; control n=85) with an estimated glomerular filtration rate <60 mL/min. Nicorandil 12 mg dissolved in 100 mL of 0.9% saline was administered intravenously for 30 minutes just prior to coronary angiography in the nicorandil group. The same volume of only saline was given to the control group. The primary endpoint was the incidence of CIN, defined as >0.5 mg/dL increase or >25% rise in serum creatinine (SCr) concentration within 48 hours of contrast exposure compared to baseline. The final analysis included 149 patients (nicorandil n=73; control n=76). The baseline characteristics and the total volume of the used contrast (Iodixanol, 125.6±69.1 mL vs. 126.9±74.6 mL, p=0.916) were similar between the two groups. The incidence of CIN also did not differ between the nicorandil and control groups (6.8% vs. 6.6%, p=0.794). There was no difference between the two groups in the relative change in SCr from baseline to peak level within 48 hours after coronary angiography (-1.58±24.07% vs. 0.96±17.49%, p=0.464), although the nicorandil group showed less absolute change in SCr than the control group (-0.01±0.43 mg/mL vs. 0.02±0.31 mg/mL, p=0.005). Prophylactic intravenous infusion of nicorandil did not decrease the incidence of CIN in patients with renal dysfunction undergoing coronary angiography.

  3. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    NASA Astrophysics Data System (ADS)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  4. Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography.

    PubMed

    Lee, Ji Won; Lee, Geewon; Lee, Nam Kyung; Moon, Jin Il; Ju, Yun Hye; Suh, Young Ju; Jeong, Yeon Joo

    2016-01-01

    The aim of the study was to assess the effectiveness of the adaptive statistical iterative reconstruction (ASIR) for dual-energy computed tomography pulmonary angiography (DE-CTPA) with a reduced iodine load. One hundred forty patients referred for chest CT were randomly divided into a DE-CTPA group with a reduced iodine load or a standard CTPA group. Quantitative and qualitative image qualities of virtual monochromatic spectral (VMS) images with filtered back projection (VMS-FBP) and those with 50% ASIR (VMS-ASIR) in the DE-CTPA group were compared. Image qualities of VMS-ASIR images in the DE-CTPA group and ASIR images in the standard CTPA group were also compared. All quantitative and qualitative indices, except attenuation value of pulmonary artery in the VMS-ASIR subgroup, were superior to those in the VMS-FBP subgroup (all P < 0.001). Noise and signal-to-noise ratio of VMS-ASIR images were superior to those of ASIR images in the standard CTPA group (P < 0.001 and P = 0.007, respectively). Regarding qualitative indices, noise was significantly lower in VMS-ASIR images of the DE-CTPA group than in ASIR images of the standard CTPA group (P = 0.001). The ASIR technique tends to improve the image quality of VMS imaging. Dual-energy computed tomography pulmonary angiography with ASIR can reduce contrast medium volume and produce images of comparable quality with those of standard CTPA.

  5. Long-term results of a randomized controlled trial analyzing the role of systematic pre-operative coronary angiography before elective carotid endarterectomy in patients with asymptomatic coronary artery disease.

    PubMed

    Illuminati, G; Schneider, F; Greco, C; Mangieri, E; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Pizzardi, G; Calio', F; Miraldi, F; Macrina, F; Totaro, M; Greco, E; Mazzesi, G; Tritapepe, L; Toscano, M; Vietri, F; Meyer, N; Ricco, J-B

    2015-04-01

    To evaluate the potential benefit of systematic preoperative coronary-artery angiography followed by selective coronary-artery revascularization on the incidence of myocardial infarction (MI) in patients undergoing carotid endarterectomy (CEA) without a previous history of coronary artery disease (CAD). We randomised 426 patients who were candidates for CEA, with no history of CAD, a normal electrocardiogram (ECG), and a normal cardiac ultrasound. In group A (n = 216) all patients underwent coronary angiography before CEA. In group B (n = 210) CEA was performed without coronary angiography. Patients were not blinded for relevant assessments during follow-up. Primary end-point was the occurrence of MI at 3.5 years. The secondary end-point was the overall survival rate. Median length of follow-up was 6.2 years. In group A, coronary angiography revealed significant coronary artery stenosis in 68 patients (31.5%). Among them, 66 underwent percutaneous Intervention (PCI) prior to CEA and 2 received combined CEA and coronary-artery bypass grafting (CABG). Postoperatively, no MI was observed in group A, whereas 6 MI occurred in group B, one of which was fatal (p = .01). During the study period, 3 MI occurred in group A (1.4%) and 33 were observed in group B (15.7%), 6 of which were fatal. The Cox model demonstrated a reduced risk of MI for patients in group A receiving coronary angiography (HR,.078; 95% CI, 0.024-0.256; p < .001). In addition, patients with diabetes and patients <70 years presented with an increased risk of MI. Survival analysis at 6 years by Kaplan-Meier estimates was 95.6 ± 3.2% in Group A and 89.7 ± 3.7% in group B (Log Rank = 6.54, p = .01). In asymptomatic coronary-artery patients, systematic coronary angiography prior to CEA followed by selective PCI or CABG significantly reduces the incidence of late MI and increases long-term survival. (ClinicalTrials.gov number, NCT02260453). Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Arterial Access in Patients With De Novo Acute Coronary Syndrome Undergoing Coronary Angiography.

    PubMed

    Abdul Jabbar, Ali; Mufti, Omar; Sabol, Angeline; Markert, Ronald; White, Bryan; Broderick, George

    2017-04-01

    Bleeding is a major limitation of antithrombotic therapy among invasively managed patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACSs). Randomized clinical trials have generally failed to favor either the femoral or the radial arterial approach for coronary angiography or intervention in NSTE-ACS. In 561 hospitalized patients with a new diagnosis of NSTE-ACS referred for coronary angiography, 364 and 197 patients underwent the femoral and the radial approach, respectively. Femoral and radial access did not differ in bleeding complications in the first 72 hours (8 of 364 or 2.2% vs 8 of 197 or 4.1%, P = .21), duration of hospitalization (4.67 ± 5.02 vs 4.51 ± 4.81, P = .28) nor in-hospital mortality (0.8% vs 0.5%, P = .67). Contrast volume was higher for femoral versus radial cases (204 ± 119 vs 168 ± 104, P < .001). In patients with de novo NSTE-ACS without prior cardiac bypass, radial and femoral arterial access did not differ in instances of bleeding within the first 72 hours postoperatively, length of hospital stay, or in-hospital mortality. Less contrast was used in radial cases, which may represent an advantage for patients with renal insufficiency.

  7. A policy for science.

    PubMed

    Lauer, Michael S

    2012-06-12

    Policy and science often interact. Typically, we think of policymakers looking to scientists for advice on issues informed by science. We may appreciate less the opposite look: where people outside science inform policies that affect the conduct of science. In clinical medicine, we are forced to make decisions about practices for which there is insufficient, inadequate evidence to know whether they improve clinical outcomes, yet the health care system may not be structured to rapidly generate needed evidence. For example, when the Centers for Medicare and Medicaid Services noted insufficient evidence to support routine use of computed tomography angiography and they called for a national commitment to completion of randomized trials, their call ran into substantial opposition. I use the computed tomography angiography story to illustrate how we might consider a "policy for science" in which stakeholders would band together to identify evidence gaps and to use their influence to promote the efficient design, implementation, and completion of high-quality randomized trials. Such a policy for science could create a culture that incentivizes and invigorates the rapid generation of evidence, ultimately engaging all clinicians, all patients, and indeed all stakeholders into the scientific enterprise. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Meta-Analysis of Individual Patient Data of Sodium Bicarbonate and Sodium Chloride for All-Cause Mortality After Coronary Angiography.

    PubMed

    Brown, Jeremiah R; Pearlman, Daniel M; Marshall, Emily J; Alam, Shama S; MacKenzie, Todd A; Recio-Mayoral, Alejandro; Gomes, Vitor O; Kim, Bokyung; Jensen, Lisette O; Mueller, Christian; Maioli, Mauro; Solomon, Richard J

    2016-11-15

    We sought to examine the relation between sodium bicarbonate prophylaxis for contrast-associated nephropathy (CAN) and mortality. We conducted an individual patient data meta-analysis from multiple randomized controlled trials. We obtained individual patient data sets for 7 of 10 eligible trials (2,292 of 2,764 participants). For the remaining 3 trials, time-to-event data were imputed based on follow-up periods described in their original reports. We included all trials that compared periprocedural intravenous sodium bicarbonate to periprocedural intravenous sodium chloride in patients undergoing coronary angiography or other intra-arterial interventions. Included trials were determined by consensus according to predefined eligibility criteria. The primary outcome was all-cause mortality hazard, defined as time from randomization to death. In 10 trials with a total of 2,764 participants, sodium bicarbonate was associated with lower mortality hazard than sodium chloride at 1 year (hazard ratio 0.61, 95% confidence interval [CI] 0.41 to 0.89, p = 0.011). Although periprocedural sodium bicarbonate was associated with a reduction in the incidence of CAN (relative risk 0.75, 95% CI 0.62 to 0.91, p = 0.003), there exists a statistically significant interaction between the effect on mortality and the occurrence of CAN (hazard ratio 5.65, 95% CI 3.58 to 8.92, p <0.001) for up to 1-year mortality. Periprocedural intravenous sodium bicarbonate seems to be associated with a reduction in long-term mortality in patients undergoing coronary angiography or other intra-arterial interventions. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Less iodine injected for the same diagnostic performances: comparison of two low-osmolar contrast agents (iobitridol 350 and iopamidol 370) in coronary angiography and ventriculography: a randomized double-blind clinical study.

    PubMed

    Velázquez, Maríia Teresa; Albarrán, Agustín; Hernández, Felipe; García Tejada, Julio; Zueco, Javier; Andreu, Javier; De la Torre, Jose-María; Figueroa, Alvaro; Sainz, Fermin; Tascón, Juan

    2010-08-01

    Mild reductions in iodine concentration could reduce acute side effects after intraarterial contrast media administration without affecting the quality of coronary artery images. This study was designed to show the equivalence in terms of image quality of two nonionic low-osmolar monomers, iobitridol 350 and iopamidol 370, and to compare their clinical safety in coronary angiography and ventriculography. In this multicentre, double-blind clinical trial, 98 adult patients were randomized to receive either iobitridol 350 or iopamidol 370. The image quality (primary evaluation criterion) of the whole examination was assessed using a 5-point scale (poor, fair, moderate, good, excellent). Secondary endpoints were the image quality per territory, diagnostic efficacy, practical comfort (5-point scale: impossible to evaluate, not practical, moderately practical, practical, very practical to use) and clinical safety (adverse events and vital signs). The proportions of examinations presenting with good or excellent global image quality was similar with both contrast media: 87.8% with iobitridol 350 vs. 89.8% with iopamidol 370. Similar results were observed when considering the image quality specifically for each major coronary artery and left ventricle. No difference between groups was found with respect to other secondary criteria. Adverse events occurred in 7 patients with iobitridol 350 (14.3%) and in 10 patients with iopamidol 370 (20.4%). This study showed that, with regard to image quality and diagnostic efficacy and using a lower iodine concentration, iobitridol 350 was comparable to iopamidol 370 in adult patients requiring coronary angiography and ventriculography for diagnostic indications.

  10. Manual Versus Mechanical Compression of the Radial Artery After Transradial Coronary Angiography: The MEMORY Multicenter Randomized Trial.

    PubMed

    Petroglou, Dimitrios; Didagelos, Matthaios; Chalikias, Georgios; Tziakas, Dimitrios; Tsigkas, Grigorios; Hahalis, Georgios; Koutouzis, Michael; Ntatsios, Antonios; Tsiafoutis, Ioannis; Hamilos, Michael; Kouparanis, Antonios; Konstantinidis, Nikolaos; Sofidis, Georgios; Pancholy, Samir B; Karvounis, Haralambos; Bertrand, Olivier Francois; Ziakas, Antonios

    2018-06-11

    The aim of this study was to compare manual versus mechanical compression of the radial artery after coronary angiography via transradial access regarding radial artery occlusion (RAO), access-site bleeding complications, and duration of hemostasis. Hemostasis of the radial artery after sheath removal can be achieved either by manual compression at the puncture site or by using a mechanical hemostasis device. Because mechanical compression exerts a more stable, continuous pressure on the artery, it could be hypothesized that it is more effective compared with manual compression regarding hemostasis time, bleeding, and RAO risks. A total of 589 patients undergoing diagnostic coronary angiography by transradial access with a 5-F sheath were randomized in a 1:1 ratio to receive either manual or mechanical patent hemostasis of the radial artery. Radial artery patency was evaluated by color duplex ultrasonography 24 h after the procedure. The primary endpoint was early RAO at 24 h. Secondary endpoints included access-site bleeding complications and duration of hemostasis. Thirty-six (12%) early RAOs occurred in the manual group, and 24 (8%) occurred in the mechanical group (p = 0.176). There were no significant differences between the 2 groups regarding access-site bleeding complications (hematoma, 52 [17%] vs. 50 [18%]; p = 0.749; bleedings, 8 [3%] vs. 9 [3%]; p = 1.000). Duration of hemostasis was significantly shorter in the manual group (22 ± 34 min vs. 119 ± 72 min with mechanical compression; p < 0.001). Manual and mechanical compression resulted in similar rates of early RAO, although the total duration of hemostasis was significantly shorter in the manual group. Copyright © 2018 American College of Cardiology Foundation. All rights reserved.

  11. Coronary angiography

    MedlinePlus

    ... Angiogram - coronary; Coronary artery disease - angiography; CAD - angiography; Angina - angiography; Heart disease - angiography ... Coronary angiography may be done if: You have angina for the first time. Your angina that is ...

  12. CT Angiography (CTA)

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z CT Angiography (CTA) Computed tomography angiography (CTA) uses an ... are the limitations of CT Angiography? What is CT Angiography? Angiography is a minimally invasive medical test ...

  13. Effect of sleep-inducing music on sleep in persons with percutaneous transluminal coronary angiography in the cardiac care unit.

    PubMed

    Ryu, Min-Jung; Park, Jeong Sook; Park, Heeok

    2012-03-01

    The study compared the effect of earplug-delivered sleep-inducing music on sleep in persons with percutaneous transluminal coronary angiography in the cardiac care unit. Diverse types of music have been claimed to improve sleeping elsewhere, but relatively little is known in South Korea. Most studies investigating the effect of sleep-inducing music on sleep have involved persons with insomnia, even though many persons with cardiovascular disease in the intensive care unit suffer from sleeping problems. There is a need to investigate the effect of sleep-inducing music on sleep disorders in persons with percutaneous transluminal coronary angiography in the cardiac care unit. An experimental research design was used. Data collection was conducted in the cardiac care unit of K University Hospital in D city, from 3 September-4 October 2010. Fifty-eight subjects participated and were randomly assigned to the experimental group (earplug-delivered sleep-inducing music for 52 min beginning at 10:00 pm, while wearing an eyeshield, n = 29) and the control group (no music, but earplugs and eyeshield worn, n = 29). The quantity and quality of sleep were measured using questionnaires at 7 am the next morning for each group. Participants in the experimental group reported that the sleeping quantity and quality were significantly higher than control group (t = 3·181, p = 0·002, t = 5·269, p < 0·001, respectively). Sleep-inducing music significantly improved sleep in patients with percutaneous transluminal coronary angiography at a cardiac care unit. Offering earplugs and playing sleep-inducing music may be a meaningful and easily enacted nursing intervention to improve sleep for intensive care unit patients. Nurses working at cardiac care unit can use music to improve sleeping in clients with percutaneous transluminal coronary angiography. © 2011 Blackwell Publishing Ltd.

  14. Monocyte Chemoattractant Protein-1 as a Predictor of Coronary Atherosclerosis in Patients Receiving Coronary Angiography.

    PubMed

    Mahler, Simon A; Register, Thomas C; Riley, Robert F; D'Agostino, Ralph B; Stopyra, Jason P; Miller, Chadwick D

    2018-06-01

    Animal studies suggest that monocyte chemoattractant protein-1 (MCP-1) is a promising biomarker for coronary artery atherosclerosis (CAA), but human studies have been inconclusive. To determine potential relationships between plasma MCP-1 and CAA in patients with acute chest pain. A secondary analysis of 150 patients enrolled in emergency department chest pain risk stratification clinical investigations was conducted. Participants with stored blood and known coronary phenotypes (determined by coronary angiography) were selected using stratified randomization such that 50 patients were included into 3 groups: (1) no angiographic evidence of CAA, (2) nonobstructive CAA, and (3) obstructive CAA (stenosis ≥ 70%). Plasma MCP-1 levels were determined by enzyme-linked immunosorbent assay. The association between MCP-1 and obstructive CAA or any CAA was modeled using logistic regression. Variables in the unreduced model included age, sex, race, prior diagnosis of CAA or acute coronary syndrome, hyperlipidemia, hypertension, diabetes, smoking, and cardiac troponin I measurement. Among the 150 participants, 65.3% (98/150) had invasive coronary angiography and 34.7% (52/150) had coronary computed tomographic angiography. Myocardial infarction occurred in 27.3% (41/150) and coronary revascularization occurred in 26% (39/150) of the participants. Each 10 pg/mL increase in MCP-1 measurement was associated with an odds ratio of 1.12 (95% confidence interval, 1.06-1.19) for obstructive CAA. MCP-1 remained a significant predictor of obstructive CAA and any CAA after adjustment for age, sex, race, traditional cardiac risk factors, and cardiac troponin I. MCP-1 is independently associated with CAA among emergency department patients with chest pain.

  15. Early versus delayed invasive strategy for intermediate- and high-risk acute coronary syndromes managed without P2Y12 receptor inhibitor pretreatment: Design and rationale of the EARLY randomized trial.

    PubMed

    Lemesle, Gilles; Laine, Marc; Pankert, Mathieu; Puymirat, Etienne; Cuisset, Thomas; Boueri, Ziad; Maillard, Luc; Armero, Sébastien; Cayla, Guillaume; Bali, Laurent; Motreff, Pascal; Peyre, Jean-Pascal; Paganelli, Franck; Kerbaul, François; Roch, Antoine; Michelet, Pierre; Baumstarck, Karine; Bonello, Laurent

    2018-01-01

    According to recent literature, pretreatment with a P2Y 12 ADP receptor antagonist before coronary angiography appears no longer suitable in non-ST-segment elevation acute coronary syndrome (NSTE-ACS) due to an unfavorable risk-benefit ratio. Optimal delay of the invasive strategy in this specific context is unknown. We hypothesize that without P2Y 12 ADP receptor antagonist pretreatment, a very early invasive strategy may be beneficial. The EARLY trial (Early or Delayed Revascularization for Intermediate- and High-Risk Non-ST-Segment Elevation Acute Coronary Syndromes?) is a prospective, multicenter, randomized, controlled, open-label, 2-parallel-group study that plans to enroll 740 patients. Patients are eligible if the diagnosis of intermediate- or high-risk NSTE-ACS is made and an invasive strategy intended. Patients are randomized in a 1:1 ratio. In the control group, a delayed strategy is adopted, with the coronary angiography taking place between 12 and 72 hours after randomization. In the experimental group, a very early invasive strategy is performed within 2 hours. A loading dose of a P2Y 12 ADP receptor antagonist is given at the time of intervention in both groups. Recruitment began in September 2016 (n = 558 patients as of October 2017). The primary endpoint is the composite of cardiovascular death and recurrent ischemic events at 1 month. The EARLY trial aims to demonstrate the superiority of a very early invasive strategy compared with a delayed strategy in intermediate- and high-risk NSTE-ACS patients managed without P2Y 12 ADP receptor antagonist pretreatment. © 2018 Wiley Periodicals, Inc.

  16. Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME): 5-year follow-up of a randomised controlled trial.

    PubMed

    van Nunen, Lokien X; Zimmermann, Frederik M; Tonino, Pim A L; Barbato, Emanuele; Baumbach, Andreas; Engstrøm, Thomas; Klauss, Volker; MacCarthy, Philip A; Manoharan, Ganesh; Oldroyd, Keith G; Ver Lee, Peter N; Van't Veer, Marcel; Fearon, William F; De Bruyne, Bernard; Pijls, Nico H J

    2015-11-07

    In the Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) study, fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) improved outcome compared with angiography-guided PCI for up to 2 years of follow-up. The aim in this study was to investigate whether the favourable clinical outcome with the FFR-guided PCI in the FAME study persisted over a 5-year follow-up. The FAME study was a multicentre trial done in Belgium, Denmark, Germany, the Netherlands, Sweden, the UK, and the USA. Patients (aged ≥ 18 years) with multivessel coronary artery disease were randomly assigned to undergo angiography-guided PCI or FFR-guided PCI. Before randomisation, stenoses requiring PCI were identified on the angiogram. Patients allocated to angiography-guided PCI had revascularisation of all identified stenoses. Patients allocated to FFR-guided PCI had FFR measurements of all stenotic arteries and PCI was done only if FFR was 0·80 or less. No one was masked to treatment assignment. The primary endpoint was major adverse cardiac events at 1 year, and the data for the 5-year follow-up are reported here. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00267774. After 5 years, major adverse cardiac events occurred in 31% of patients (154 of 496) in the angiography-guided group versus 28% (143 of 509 patients) in the FFR-guided group (relative risk 0·91, 95% CI 0·75-1·10; p=0·31). The number of stents placed per patient was significantly higher in the angiography-guided group than in the FFR-guided group (mean 2·7 [SD 1·2] vs 1·9 [1·3], p<0·0001). The results confirm the long-term safety of FFR-guided PCI in patients with multivessel disease. A strategy of FFR-guided PCI resulted in a significant decrease of major adverse cardiac events for up to 2 years after the index procedure. From 2 years to 5 years, the risks for both groups developed similarly. This clinical outcome in the FFR-guided group was achieved with a lower number of stented arteries and less resource use. These results indicate that FFR guidance of multivessel PCI should be the standard of care in most patients. St Jude Medical, Friends of the Heart Foundation, and Medtronic. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Early versus delayed, provisional eptifibatide in acute coronary syndromes.

    PubMed

    Giugliano, Robert P; White, Jennifer A; Bode, Christoph; Armstrong, Paul W; Montalescot, Gilles; Lewis, Basil S; van 't Hof, Arnoud; Berdan, Lisa G; Lee, Kerry L; Strony, John T; Hildemann, Steven; Veltri, Enrico; Van de Werf, Frans; Braunwald, Eugene; Harrington, Robert A; Califf, Robert M; Newby, L Kristin

    2009-05-21

    Glycoprotein IIb/IIIa inhibitors are indicated in patients with acute coronary syndromes who are undergoing an invasive procedure. The optimal timing of the initiation of such therapy is unknown. We compared a strategy of early, routine administration of eptifibatide with delayed, provisional administration in 9492 patients who had acute coronary syndromes without ST-segment elevation and who were assigned to an invasive strategy. Patients were randomly assigned to receive either early eptifibatide (two boluses, each containing 180 microg per kilogram of body weight, administered 10 minutes apart, and a standard infusion > or = 12 hours before angiography) or a matching placebo infusion with provisional use of eptifibatide after angiography (delayed eptifibatide). The primary efficacy end point was a composite of death, myocardial infarction, recurrent ischemia requiring urgent revascularization, or the occurrence of a thrombotic complication during percutaneous coronary intervention that required bolus therapy opposite to the initial study-group assignment ("thrombotic bailout") at 96 hours. The key secondary end point was a composite of death or myocardial infarction within the first 30 days. Key safety end points were bleeding and the need for transfusion within the first 120 hours after randomization. The primary end point occurred in 9.3% of patients in the early-eptifibatide group and in 10.0% in the delayed-eptifibatide group (odds ratio, 0.92; 95% confidence interval [CI], 0.80 to 1.06; P=0.23). At 30 days, the rate of death or myocardial infarction was 11.2% in the early-eptifibatide group, as compared with 12.3% in the delayed-eptifibatide group (odds ratio, 0.89; 95% CI, 0.79 to 1.01; P=0.08). Patients in the early-eptifibatide group had significantly higher rates of bleeding and red-cell transfusion. There was no significant difference between the two groups in rates of severe bleeding or nonhemorrhagic serious adverse events. In patients who had acute coronary syndromes without ST-segment elevation, the use of eptifibatide 12 hours or more before angiography was not superior to the provisional use of eptifibatide after angiography. The early use of eptifibatide was associated with an increased risk of non-life-threatening bleeding and need for transfusion. (ClinicalTrials.gov number, NCT00089895.) 2009 Massachusetts Medical Society

  18. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    PubMed

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Two 5 × 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Indocyanine green dye angiography may provide valuable information as to graft integrity and split-thickness skin graft timing at late time points. Range of LDI seems to be insufficient for split-thickness graft timing or late time point accuracy. Future exploration of ICG angiography potential will involve tracking Integra graft delay in porcine models.

  19. Acetylcysteine for prevention of contrast-induced nephropathy after intravascular angiography: A systematic review and meta-analysis

    PubMed Central

    Bagshaw, Sean M; Ghali, William A

    2004-01-01

    Background Contrast-induced nephropathy is an important cause of acute renal failure. We assess the efficacy of acetylcysteine for prevention of contrast-induced nephropathy among patients undergoing intravascular angiography. Methods We conducted a systematic review and meta-analysis of randomized controlled trials comparing prophylactic acetylcysteine plus hydration versus hydration alone in patients undergoing intravascular angiography. Studies were identified by searching MEDLINE, EMBASE, and CENTRAL databases. Our main outcome measures were the risk of contrast-induced nephropathy and the difference in serum creatinine between acetylcysteine and control groups at 48 h. Results Fourteen studies involving 1261 patients were identified and included for analysis, and findings were heterogeneous across studies. Acetylcysteine was associated with a significantly reduced incidence of contrast-induced nephropathy in five studies, and no difference in the other nine (with a trend toward a higher incidence in six of the latter studies). The pooled odds ratio for contrast-induced nephropathy with acetylcysteine relative to control was 0.54 (95% CI, 0.32–0.91, p = 0.02) and the pooled estimate of difference in 48-h serum creatinine for acetylcysteine relative to control was -7.2 μmol/L (95% CI -19.7 to 5.3, p = 0.26). These pooled values need to be interpreted cautiously because of the heterogeneity across studies, and due to evidence of publication bias. Meta-regression suggested that the heterogeneity might be partially explained by whether the angiography was performed electively or as emergency. Conclusion These findings indicate that published studies of acetylcysteine for prevention of contrast-induced nephropathy yield inconsistent results. The efficacy of acetylcysteine will remain uncertain unless a large well-designed multi-center trial is performed. PMID:15500690

  20. Bacterial Contamination During Diagnostic and Interventional Neuroangiography is a Frequent Finding: But Does It Matter? An Observational Study.

    PubMed

    Kabbasch, C; Dorn, F; Wenchel, H M; Krug, B; Mpotsaris, A; Liebig, T

    2017-03-01

    Bacterial contamination during angiographic procedures is a potential source of bacteremia. It is largely unknown whether it is clinically relevant. Our aim was to evaluate the incidence of contamination of liquids during catheter-based neuroangiographic examinations, the spectrum of microorganisms, a comparison of two different trolley-settings, and a follow-up of all patients with regard to clinical and lab signs of infection. A total of 170 patients underwent either diagnostic angiography (n = 111) or arterial neuroendovascular procedures (n = 59). To study the impact of airborne contamination of sterile liquids, we randomly assigned equal numbers of procedures to two distinct setups. Group A with standard open-surface bowls and group B with repetitive coverage of liquids throughout the procedure. Patient preparation was performed with utmost care. After each procedure, samples of the liquids were sent for microbiological evaluation. Patients were followed for signs of infection (fever, white blood cell count, C-reactive-protein). Of all samples, 25.3 % were contaminated. Contamination consisted of resident skin microbiota only and was more common with procedures (28.8 %) than with diagnostic angiography (23.4 %) and less common in uncovered (23.5 %) than in covered bowls (27.1 %). However, these differences were insignificant. None of the patients developed clinical or lab signs of infection. Contamination during diagnostic and interventional angiography does occur and cannot be avoided by intermittent coverage. Despite a surprisingly high incidence, our findings support the common strategy that antibiotic coverage is unnecessary in most patients undergoing arterial angiography as it lacks clinical impact. Airborne contamination does not appear to play a role.

  1. Sensitivity and specificity of the hyperdense artery sign for arterial obstruction in acute ischemic stroke.

    PubMed

    Mair, Grant; Boyd, Elena V; Chappell, Francesca M; von Kummer, Rüdiger; Lindley, Richard I; Sandercock, Peter; Wardlaw, Joanna M

    2015-01-01

    In acute ischemic stroke, the hyperdense artery sign (HAS) on noncontrast computed tomography (CT) is thought to represent intraluminal thrombus and, therefore, is a surrogate of arterial obstruction. We sought to assess the accuracy of HAS as a marker of arterial obstruction by thrombus. The Third International Stroke Trial (IST-3) was a randomized controlled trial testing the use of intravenous thrombolysis for acute ischemic stroke in patients who did not clearly meet the prevailing license criteria. Some participating IST-3 centers routinely performed CT or MR angiography at baseline. One reader assessed all relevant scans independently, blinded to all other data; we checked observer reliability. We combined IST-3 data with a systematic review and meta-analysis of all studies that assessed the accuracy of HAS using angiography (any modality). IST-3 had 273 patients with baseline CT or MR angiography and was the largest study of HAS accuracy. The meta-analysis (n=902+273=1175, including IST-3) found sensitivity and specificity of HAS for arterial obstruction on angiography to be 52% and 95%, respectively. HAS was more commonly identified in proximal than distal arteries (47% versus 37%; P=0.015), and its sensitivity increased with thinner CT slices (r=-0.73; P=0.001). Neither extent of obstruction nor time after stroke influenced HAS accuracy. When present in acute ischemic stroke, HAS indicates a high likelihood of arterial obstruction, but its absence indicates only a 50/50 chance of normal arterial patency. Thin-slice CT improves sensitivity of HAS detection. http://www.controlled-trials.com/ISRCTN25765518. Unique identifier: ISRCTN25765518. © 2014 American Heart Association, Inc.

  2. Gadolinium-enhanced magnetic resonance angiography in renal artery stenosis: comparison with digital subtraction angiography.

    PubMed

    Law, Y M; Tay, K H; Gan, Y U; Cheah, F K; Tan, B S

    2008-04-01

    To evaluate the accuracy of gadolinium-enhanced magnetic resonance angiography in assessing renal artery stenosis compared to catheter digital subtraction angiography. Retrospective study. Singapore General Hospital. Records of patients who underwent magnetic resonance angiography as well as digital subtraction angiography for assessment of renal artery stenosis from January 2003 to December 2005 were reviewed. There were 27 patients (14 male, 13 female) with a mean age of 62 (range, 44-77) years. There were 10 patients with renal transplants; their native renal arteries were not evaluated. Each of the two experienced interventional and body magnetic resonance radiologists, who were blinded to the results, reviewed the digital subtraction angiography and magnetic resonance angiography images respectively. Digital subtraction angiography was used as the standard of reference. A total of 39 renal arteries from these 27 patients were evaluated. One of the arteries was previously stented and could not be assessed with magnetic resonance angiography due to severe artefacts. Of the remaining 38 renal arteries, two were graded as normal, seven as having mild stenosis (<50%), eight as having moderate stenosis (> or =50% but <75%), and 21 as having severe stenosis (> or =75%). Magnetic resonance angiography and digital subtraction angiography were concordant in 89% of the arteries; magnetic resonance angiography overestimated the degree of stenosis in 8% and underestimated it in 3% of them. In the evaluation of clinically significant renal artery stenosis (> or =50%) with magnetic resonance angiography, the overall sensitivity, specificity, positive predictive value, and negative predictive value were 97%, 67%, 90%, and 86% respectively. The sensitivity and specificity of magnetic resonance angiography in transplant renal artery stenosis was 100%. CONCLUSION. Our experience suggested that gadolinium-enhanced magnetic resonance angiography is a sensitive non-invasive modality useful in the assessment of clinically significant renal artery stenosis.

  3. Rationale and design of a randomized trial comparing initial stress echocardiography versus coronary CT angiography in low-to-intermediate risk emergency department patients with chest pain.

    PubMed

    Levsky, Jeffrey M; Haramati, Linda B; Taub, Cynthia C; Spevack, Daniel M; Menegus, Mark A; Travin, Mark I; Vega, Shayna; Lerer, Rikah; Brown-Manhertz, Durline; Hirschhorn, Esther; Tobin, Jonathan N; Garcia, Mario J

    2014-07-01

    Comparative effectiveness research (CER) has become a major focus of cardiovascular disease investigation to optimize diagnosis and treatment paradigms and decrease healthcare expenditures. Acute chest pain is a highly prevalent reason for evaluation in the Emergency Department (ED) that results in hospital admission for many patients and excess expense. Improvement in noninvasive diagnostic algorithms can potentially reduce unnecessary admissions. To compare the performance of treadmill stress echocardiography (SE) and coronary computed tomography angiography (CTA) in ED chest pain patients with low-to-intermediate risk of significant coronary artery disease. This is a single-center, randomized controlled trial (RCT) comparing SE and CTA head-to-head as the initial noninvasive imaging modality. The primary outcome measured is the incidence of hospitalization. The study is powered to detect a reduction in admissions from 28% to 15% with a sample size of 400. Secondary outcomes include length of stay in the ED/hospital and estimated cost of care. Safety outcomes include subsequent visits to the ED and hospitalizations, as well as major adverse cardiovascular events at 30 days and 1 year. Patients who do not meet study criteria or do not consent for randomization are offered entry into an observational registry. This RCT will add to our understanding of the roles of different imaging modalities in triaging patients with suspected angina. It will increase the CER evidence base comparing SE and CTA and provide insight into potential benefits and limitations of appropriate use of treadmill SE in the ED. © 2013, Wiley Periodicals, Inc.

  4. Comparison of Temporary Open Arterial Revascularization Using Stent Grafts vs. Standard Vascular Shunts in a Porcine (Sus scrofa) Model

    DTIC Science & Technology

    2017-01-24

    Objectives: Open surgical reconstruction using expanded polytetrafluoroethylene stent grafts to create a sutureless anastomosis is an alternative to...French Argyle shunt was inserted into one randomly assigned artery, with a self-expanding ePTFE stent deployed in the other. Arterial flow measurements...for histopathology were obtained during the terminal procedure. Results: Angiography revealed no difference in patency at 72 hours. The stent grafts

  5. Efficacy of RADPAD protective drape during coronary angiography.

    PubMed

    Kherad, B; Jerichow, T; Blaschke, F; Noutsias, M; Pieske, B; Tschöpe, C; Krackhardt, F

    2018-06-01

    Ionizing radiation is an integral part of percutaneous coronary angiographies. Chronic exposure to low-dose radiation confers a risk for skin damage, eye lens opacities or cataracts, and malignant diseases to staff in the catheter laboratory. The RADPAD is a sterile surgical drape that reduces the effect of scatter radiation on the operator. We sought to assess the efficacy of RADPAD shields in reducing radiation dose experienced by operators during routine diagnostic coronary angiography. Sixty consecutive patients due to undergo elective coronary angiography were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There was no significant difference in the two main determents of radiation exposure in both groups: the screening times (102 ± 86 s for the RADPAD group vs. 105 ± 36 s for the control group, p = 0.9) and body mass index (BMI; 27.7 ± 4.2 kg/m 2 for the RADPAD group vs. 27.9 ± 5.5 kg/m 2 for the control group, p = 0.8). Moreover, there was no difference in the dose-area ratio (1337 ± 582 cGy/cm 2 for the RADPAD group vs. 1541 ± 804 cGy/cm 2 for the control group, p = 0.3) between the two patient groups. The primary operator radiation dose was significantly lower in the RADPAD group at 8.0 µSv (Q1: 3.2, Q3: 20.1) compared with 19.6 µSv (Q1: 7.1, Q3: 37.7) for the control group (p = 0.02). The RADPAD significantly reduces radiation exposure to primary operators during routine diagnostic coronary angiography in patients with a BMI > 25 kg/m 2 . It reduces total radiation exposure to primary operators by 59%, and the radiation exposure rate by 47%.

  6. Benefit of immediate coronary angiography after out-of-hospital cardiac arrest in France: A nationwide propensity score analysis from the RéAC Registry.

    PubMed

    Jaeger, Déborah; Dumas, Florence; Escutnaire, Josephine; Sadoune, Sonia; Lauvray, Adrien; Elkhoury, Carlos; Bassand, Adrien; Girerd, Nicolas; Gueugniaud, Pierre Yves; Tazarourte, Karim; Hubert, Hervé; Cariou, Alain; Chouihed, Tahar

    2018-05-01

    The survival rate of out-of-hospital cardiac arrest (OHCA) remains extremely low, generally under 10%. Post-resuscitation care, and particularly early coronary reperfusion, may improve this outcome. The main objective of the present study was to determine whether patients with immediate coronary angiography at hospital admission (CAA) had a better outcome than patients without immediate CAA. This cohort analysis study was based on data extracted from the French National Cardiac Arrest registry (RéAC). To control for attribution bias, patients were matched using a propensity score, which included age clusters, low flow and no flow delays, initial rhythm and bystander cardiopulmonary resuscitation (CPR). The main endpoint was survival at day 30 (D30). Secondary endpoint was neurological recovery of survivors assessed by the Cerebral Performance Category (CPC) scale, with CPC 1 and 2 at D30 considered as a favorable outcome. From July 1st, 2011 to October 1st, 2016, 63394 OHCA were registered in the database, of which 39444 were of an unknown or suspected cardiac origin. After on-site resuscitation by a mobile medical team, 7584 patients were transported to a hospital facility. Among these patients, 4046 were retained in the analysis after matching for the aforementioned factors and constituted into 2 groups: immediate coronary angiography (iCAA) group (n = 2023) and non-immediate coronary angiography (niCAA) group (n = 2023). The survival rate at D30 after matching was 43.3% in the iCAA group versus 34.5% in the niCAA group (OD = 0.66 [0.58; 0.75], p < 0.001). In the iCAA group, (n = 707) 36% of the patients at D30 were CPC 1-2 comparatively to (n = 539) 27.3% in the niCAA group (p < 0.01). Both the survival and proportion of patients with favorable neurological recovery were significantly higher in patients who underwent an immediate coronary angiography after a resuscitated OHCA. These observational results warrant further exploration of the benefit of this invasive strategy in randomized studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Free and open-source software application for the evaluation of coronary computed tomography angiography images.

    PubMed

    Hadlich, Marcelo Souza; Oliveira, Gláucia Maria Moraes; Feijóo, Raúl A; Azevedo, Clerio F; Tura, Bernardo Rangel; Ziemer, Paulo Gustavo Portela; Blanco, Pablo Javier; Pina, Gustavo; Meira, Márcio; Souza e Silva, Nelson Albuquerque de

    2012-10-01

    The standardization of images used in Medicine in 1993 was performed using the DICOM (Digital Imaging and Communications in Medicine) standard. Several tests use this standard and it is increasingly necessary to design software applications capable of handling this type of image; however, these software applications are not usually free and open-source, and this fact hinders their adjustment to most diverse interests. To develop and validate a free and open-source software application capable of handling DICOM coronary computed tomography angiography images. We developed and tested the ImageLab software in the evaluation of 100 tests randomly selected from a database. We carried out 600 tests divided between two observers using ImageLab and another software sold with Philips Brilliance computed tomography appliances in the evaluation of coronary lesions and plaques around the left main coronary artery (LMCA) and the anterior descending artery (ADA). To evaluate intraobserver, interobserver and intersoftware agreements, we used simple and kappa statistics agreements. The agreements observed between software applications were generally classified as substantial or almost perfect in most comparisons. The ImageLab software agreed with the Philips software in the evaluation of coronary computed tomography angiography tests, especially in patients without lesions, with lesions < 50% in the LMCA and < 70% in the ADA. The agreement for lesions > 70% in the ADA was lower, but this is also observed when the anatomical reference standard is used.

  8. Cerebral angiography

    MedlinePlus

    ... Carotid angiogram; Cervicocerebral catheter-based angiography; Intra-arterial digital subtraction angiography; IADSA ... with the dye are seen. This is called digital subtraction angiography (DSA). After the x-rays are ...

  9. Patient satisfaction with the consent discussion is not improved by showing patients their computed tomography or angiography images before they undergo vascular surgery.

    PubMed

    LeBlanc, Dominic; Power, Adam H; DeRose, Guy; Duncan, Audra; Dubois, Luc

    2018-05-18

    Patient-based decision aids and other multimedia tools have been developed to help enrich the preoperative discussion between surgeon and patient. Use of these tools, however, can be time-consuming and logistically challenging. We investigated whether simply showing patients their images from preoperative computed tomography (CT) or angiography would improve patients' satisfaction with the preoperative discussion. We also examined whether this improved the patient's understanding and trust and whether it contributed to increased preoperative anxiety. Patients undergoing either elective abdominal aortic aneurysm repair or lower limb revascularization were randomly assigned to either standard perioperative discussion or perioperative discussion and review of images (CT image or angiogram). Randomization was concealed and stratified by surgeon. Primary outcome was patient satisfaction with the preoperative discussion as measured by a validated 7-item scale (score, 0-28), with higher scores indicating improved satisfaction. Secondary outcomes included patient understanding, patient anxiety, patient trust, and length of preoperative discussion. Scores were compared using t-test. Overall, 51 patients were randomized, 25 to the intervention arm (discussion and imaging) and 26 to the control arm. Most patients were male (69%), and the average age was 70 years. Forty percent of patients underwent abdominal aortic aneurysm repair, whereas 60% underwent lower limb revascularization. Patient satisfaction with the discussion was generally high, with no added improvement when preoperative images were reviewed (mean score, 24.9 ± 3.02 vs 24.8 ± 2.93; P = .88). Similarly, there was no difference in the patient's anxiety, level of trust, or understanding when the imaging review was compared with standard discussion. There was a trend toward longer preoperative discussions in the group that underwent imaging review (8.18 vs 6.35 minutes; P = .07). Showing patients their CT or angiography images during the preoperative discussion does not improve the patient's satisfaction with the consent discussion. Similarly, there was no effect on the patient's trust, understanding, or anxiety level. Our conclusions are limited by the lack of a standardized measure of patient understanding and not measuring outcomes postoperatively, both of which should be considered in future studies. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Prospective randomized comparison of rotational angiography with three-dimensional reconstruction and computed tomography merged with electro-anatomical mapping: a two center atrial fibrillation ablation study.

    PubMed

    Anand, Rishi; Gorev, Maxim V; Poghosyan, Hermine; Pothier, Lindsay; Matkins, John; Kotler, Gregory; Moroz, Sarah; Armstrong, James; Nemtsov, Sergei V; Orlov, Michael V

    2016-08-01

    To compare the efficacy and accuracy of rotational angiography with three-dimensional reconstruction (3DATG) image merged with electro-anatomical mapping (EAM) vs. CT-EAM. A prospective, randomized, parallel, two-center study conducted in 36 patients (25 men, age 65 ± 10 years) undergoing AF ablation (33 % paroxysmal, 67 % persistent) guided by 3DATG (group 1) vs. CT (group 2) image fusion with EAM. 3DATG was performed on the Philips Allura Xper FD 10 system. Procedural characteristics including time, radiation exposure, outcome, and navigation accuracy were compared between two groups. There was no significant difference between the groups in total procedure duration or time spent for various procedural steps. Minor differences in procedural characteristics were present between two centers. Segmentation and fusion time for 3DATG or CT-EAM was short and similar between both centers. Accuracy of navigation guided by either method was high and did not depend on left atrial size. Maintenance of sinus rhythm between the two groups was no different up to 24 months of follow-up. This study did not find superiority of 3DATG-EAM image merge to guide AF ablation when compared to CT-EAM fusion. Both merging techniques result in similar navigation accuracy.

  11. Hematoma Expansion Following Acute Intracerebral Hemorrhage

    PubMed Central

    Brouwers, H. Bart; Greenberg, Steven M.

    2013-01-01

    Intracerebral hemorrhage, the most devastating form of stroke, has no specific therapy proven to improve outcome by randomized controlled trial. Location and baseline hematoma volume are strong predictors of mortality, but are non-modifiable by the time of diagnosis. Expansion of the initial hematoma is a further marker of poor prognosis that may be at least partly preventable. Several risk factors for hematoma expansion have been identified, including baseline ICH volume, early presentation after symptom onset, anticoagulation, and the CT angiography spot sign. Although the biological mechanisms of hematoma expansion remain unclear, accumulating evidence supports a model of ongoing secondary bleeding from ruptured adjacent vessels surrounding the initial bleeding site. Several large clinical trials testing therapies aimed at preventing hematoma expansion are in progress, including aggressive blood pressure reduction, treatment with recombinant factor VIIa guided by CT angiography findings, and surgical intervention for superficial hematomas without intraventricular extension. Hematoma expansion is so far the only marker of outcome that is amenable to treatment and thus a potentially important therapeutic target. PMID:23466430

  12. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-carterial nitroglycerin in transradial procedures: a randomized trial.

    PubMed

    Turan, Burak; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-01-01

    Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Total of 101 participants (mean age 60±11years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36-75] vs 50 [35-90] sec), puncture attempts (1.18±0.48 vs 1.20±0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients <1.65m height (47 [36-66] vs 63 [41-110] sec, p=0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p=0.028) or in patients <1.65m height (7.4 vs 25%, p=0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p=0.089). SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Myocardial perfusion 320-row multidetector computed tomography-guided treatment strategy for the clinical management of patients with recent acute-onset chest pain: Design of the CArdiac cT in the treatment of acute CHest pain (CATCH)-2 randomized controlled trial.

    PubMed

    Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F

    2016-09-01

    Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial.

    PubMed

    Karády, Júlia; Panajotu, Alexisz; Kolossváry, Márton; Szilveszter, Bálint; Jermendy, Ádám L; Bartykowszki, Andrea; Károlyi, Mihály; Celeng, Csilla; Merkely, Béla; Maurovich-Horvat, Pál

    2017-11-01

    Contrast media (CM) extravasation is a well-known complication of CT angiography (CTA). Our prospective randomized control study aimed to assess whether a four-phasic CM administration protocol reduces the risk of extravasation compared to the routinely used three-phasic protocol in coronary CTA. Patients referred to coronary CTA due to suspected coronary artery disease were included in the study. All patients received 400 mg/ml iomeprol CM injected with dual-syringe automated injector. Patients were randomized into a three-phasic injection-protocol group, with a CM bolus of 85 ml followed by 40 ml of 75%:25% saline/CM mixture and 30 ml saline chaser bolus; and a four-phasic injection-protocol group, with a saline pacer bolus of 10 ml injected at a lower flow rate before the three-phasic protocol. 2,445 consecutive patients were enrolled (mean age 60.6 ± 12.1 years; females 43.6%). Overall rate of extravasation was 0.9% (23/2,445): 1.4% (17/1,229) in the three-phasic group and 0.5% (6/1,216) in the four-phasic group (p = 0.034). Four-phasic CM administration protocol is easy to implement in the clinical routine at no extra cost. The extravasation rate is reduced by 65% with the application of the four-phasic protocol compared to the three-phasic protocol in coronary CTA. • Four-phasic CM injection-protocol reduces extravasation rate by 65% compared to three-phasic. • The saline pacer bolus substantially reduces the risk of CM extravasation. • The implementation of four-phasic injection-protocol is at no cost.

  15. Study design and rationale of the 'Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial': study protocol for a randomized controlled trial.

    PubMed

    Choi, Woong Gil; Rha, Seung Woon; Choi, Cheol Ung; Kim, Eung Ju; Oh, Dong Joo; Cho, Yoon Hyung; Park, Sang Ho; Lee, Seung Jin; Hur, Ae Yong; Ko, Young Guk; Park, Sang Min; Kim, Ki Chang; Kim, Joo Han; Kim, Min Woong; Kim, Sang Min; Bae, Jang Ho; Bong, Jung Min; Kang, Won Yu; Seo, Jae Bin; Jung, Woo Yong; Cho, Jang Hyun; Kim, Do Hoi; Ahn, Ji Hoon; Kim, Soo Hyun; Jang, Ji Yong

    2016-06-25

    The self-expandable COMPLETE™ stent (Medtronic) has greater elasticity, allowing it to regain its shape after the compression force reduces, and has higher trackability, thus is easier to maneuver through tortuous vessels, whereas the balloon-expandable SCUBA™ stent (Medtronic) has higher radial stiffness and can afford more accurate placement without geographic miss, which is important in aortoiliac bifurcation lesions. To date, there have been no randomized control trials comparing efficacy and safety between the self-expanding stent and balloon-expandable stent in advanced atherosclerotic iliac artery disease. The purpose of our study is to examine primary patency (efficacy) and incidence of stent fracture and geographic miss (safety) between two different major representative stents, the self-expanding nitinol stent (COMPLETE-SE™) and the balloon-expanding cobalt-chromium stent (SCUBA™), in stenotic or occlusive iliac arterial lesions. This trial is designed as a prospective, randomized, multicenter trial to demonstrate a noninferiority of SCUBA™ stent to COMPLETE-SE™ stent following balloon angioplasty in iliac arterial lesions, and a total of 280 patients will be enrolled. The primary end point of this study is the rate of primary patency in the treated segment at 12 months after intervention as determined by catheter angiography, computed tomography angiography, or duplex ultrasound. The SENS-ILIAC trial will give powerful insight into whether the stent choice according to deployment mechanics would impact stent patency, geographic miss, or stent fracture in patients undergoing stent implantation in iliac artery lesions. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier: NCT01834495 ), registration date: May 8, 2012.

  16. Rationale, design, and baseline characteristics of the Acetylcystein for Contrast-Induced nephropaThy (ACT) Trial: a pragmatic randomized controlled trial to evaluate the efficacy of acetylcysteine for the prevention of contrast-induced nephropathy

    PubMed Central

    2009-01-01

    Background Aceltylcysteine has been evaluated in several small trials as a means of reducing the risk of contrast-induced nephropathy (CIN), however systematic reviews of these studies do not provide conclusive answers. Therefore, a large randomized controlled trial (RCT) is needed to provide a reliable answer as to whether acetylcysteine is effective in decreasing the risk of CIN in high-risk patients undergoing angiographic procedures. Methods ACT is a RCT of acetylcysteine versus placebo in 2,300 patients at-risk for CIN undergoing an intravascular angiographic procedure. The randomization list will be concealed. Participants, health care staff, investigators and outcome assessors will be blinded to whether patients receive acetylcysteine or placebo. All analysis will follow the intention-to-treat principle. The study drugs (acetylcysteine 1200 mg or placebo) will be administered orally twice daily for two doses before and two doses after the procedure. The primary outcome is the occurrence of CIN, defined as a 25% elevation of serum creatinine above baseline between 48 and 96 hours after angiography. Discussion The first patient entered the trial on September, 2008. Up to April 7, 2009, 810 patients had been included in 35 centers. The mean age was 69 (Standard deviation: 10), 18% had a baseline serum creatinine >1.5 mg/dL, 57% were diabetics and 13% had a history of heart failure. The ongoing ACT Trial is the largest multicentre RCT that will determine whether acetylcysteine is effective in decreasing the risk of CIN in patients at risk undergoing angiography. Trial registration Clinicaltrials.gov NCT00736866 PMID:19497091

  17. Pedal angiography in peripheral arterial occlusive disease: first-pass i.v. contrast-enhanced MR angiography with blood pool contrast medium versus intraarterial digital subtraction angiography.

    PubMed

    Kos, Sebastian; Reisinger, Clemens; Aschwanden, Markus; Bongartz, Georg M; Jacob, Augustinus L; Bilecen, Deniz

    2009-03-01

    The purpose of this study was to prospectively evaluate first-pass i.v. gadofosveset-enhanced MR angiography in patients with peripheral arterial occlusive disease for visualization of the pedal arteries and stenosis or occlusion of those arteries with intraarterial digital subtraction angiography as the reference standard. Twenty patients with peripheral arterial occlusive disease (nine women, 11 men; age-range 58-83 years) were prospectively enrolled. Gadofosveset first-pass contrast-enhanced MR angiography was performed with a 1.5-T system, a dedicated foot coil, and cuff compression to the calf. Arterial segments were assessed for degree of arterial stenosis, arterial visibility, diagnostic utility, and venous contamination. Detection of vessel stenosis or occlusion was evaluated in comparison with findings at digital subtraction angiography. The unpaired Student's t test was used to test arterial visibility with the two techniques. First-pass MR angiography with gadofosveset had good diagnostic utility in 83.9% of all segments and no venous contamination in 96.8% of all segments. There was no difference between the performance of intraarterial digital subtraction angiography and that of i.v. contrast-enhanced MR angiography in arterial visibility overall (p = 0.245) or in subgroup analysis of surgical arterial bypass targets (p = 0.202). The overall sensitivity, specificity, and accuracy of i.v. gadofosveset-enhanced MR angiography for characterization of clinically significant stenosis and occlusion were 91.4%, 96.1%, and 93.9%. In the subgroup analysis, the sensitivity, specificity, and accuracy were 85.5%, 96.5%, and 92.1%. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with peripheral arterial occlusive disease has arterial visibility equal to that of digital subtraction angiography and facilitates depiction of clinically significant stenosis and occlusion.

  18. Stenosis detection in native hemodialysis fistulas with MDCT angiography.

    PubMed

    Heye, Sam; Maleux, Geert; Claes, Kathleen; Kuypers, Dirk; Oyen, Raymond

    2009-04-01

    The objective of our study was to assess the diagnostic value of 64-MDCT angiography in the evaluation of failing hemodialysis arteriovenous fistulas (AVFs) in comparison with conventional digital subtraction angiography (DSA). Thirty-six patients (22 men; mean age +/- SD, 65 +/- 15 years) with hemodialysis fistula dysfunction underwent MDCT angiography before DSA. Linear weighted kappa was used to calculate interobserver agreement for stenosis for both MDCT angiography and DSA on a 5-point scale. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the detection of >/= 50% stenosis or occlusion on MDCT angiography was calculated using DSA as the standard of reference. Wilcoxon's signed rank test and Mann-Whitney U test were used to compare differences in image quality between MDCT angiography and DSA and between MDCT angiography with the patient's arm stretched overhead or alongside the body, respectively. Interobserver agreement for detecting stenosis was excellent for both DSA (kappa = 0.86; 95% CI, 0.81-0.91) and MDCT angiography (kappa = 0.82; 95% CI, 0.77-0.87). Accuracy, sensitivity, specificity, PPV, and NPV of MDCT angiography for detecting >/= 50% stenosis or occlusion was 92.0% (95% CI, 86.8-95.3%), 90.2% (77.8-96.3%), 92.8% (85.9-96.6%), 85.2% (72.3-92.9%), and 95.4% (89.0-98.3%), respectively. No significant difference in image quality was seen between MDCT angiography and DSA (p = 0.3008) or between MDCT angiography with the patient's arm stretched overhead or alongside the body (p = 0.2912). MDCT angiography is a reproducible and reliable imaging technique for detection of >/= 50% stenosis or occlusion in dysfunctional hemodialysis fistulas.

  19. Contemporary Patterns of Early Coronary Angiography Use in Patients With Non-ST-Segment Elevation Myocardial Infarction in the United States: Insights From the National Cardiovascular Data Registry Acute Coronary Treatment and Intervention Outcomes Network Registry.

    PubMed

    Malta Hansen, Carolina; Wang, Tracy Y; Chen, Anita Y; Chiswell, Karen; Bhatt, Deepak L; Enriquez, Jonathan R; Henry, Timothy; Roe, Matthew T

    2018-02-26

    The study sought to characterize patient- and hospital-level variation in early angiography use among non-ST-segment elevation myocardial infarction (NSTEMI) patients. Contemporary implementation of guideline recommendations for early angiography use in NSTEMI patients in the United States have not been described. The study analyzed NSTEMI patients included in ACTION (Acute Coronary Treatment and Intervention Outcomes Network) registry (2012 to 2014) who underwent in-hospital angiography. Timing of angiography was categorized as early (≤24 h) vs. delayed (>24 h). The study evaluated factors associated with early angiography, hospital-level variation in early angiography use, and the relationship with quality-of-care measures. A total of 79,760 of 138,688 (57.5%) patients underwent early angiography. Factors most strongly associated with delayed angiography included weekend or holiday presentation, lower initial troponin ratio values, higher initial creatinine values, heart failure on presentation, and older age. Median hospital-level use of early angiography was 58.5% with wide variation across hospitals (21.7% to 100.0%). Patient characteristics did not differ substantially across hospitals grouped by tertiles of early angiography use (low, middle, and high). Hospitals in the highest tertile tended to more commonly use guideline-recommended medications and had higher defect-free care quality scores. In contemporary U.S. practice, high-risk clinical characteristics were associated with lower use of early angiography in NSTEMI patients; hospital-level use of early angiography varied widely despite few differences in case mix. Hospitals that most commonly utilized early angiography also had higher quality-of-care metrics, highlighting the need for improved NSTEMI guideline adherence. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

    PubMed

    Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh

    2015-04-22

    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.

  1. Randomised trial of no hydration vs. sodium bicarbonate hydration in patients with chronic kidney disease undergoing acute computed tomography-pulmonary angiography.

    PubMed

    Kooiman, J; Sijpkens, Y W J; van Buren, M; Groeneveld, J H M; Ramai, S R S; van der Molen, A J; Aarts, N J M; van Rooden, C J; Cannegieter, S C; Putter, H; Rabelink, T J; Huisman, M V

    2014-10-01

    Hydration to prevent contrast-induced acute kidney injury (CI-AKI) induces a diagnostic delay when performing computed tomography-pulmonary angiography (CTPA) in patients suspected of having acute pulmonary embolism. To analyze whether withholding hydration is non-inferior to sodium bicarbonate hydration before CTPA in patients with chronic kidney disease (CKD). We performed an open-label multicenter randomized trial between 2009 and 2013. One hundred thirty-nine CKD patients were randomized, of whom 138 were included in the intention-to-treat population: 67 were randomized to withholding hydration and 71 were randomized to 1-h 250 mL 1.4% sodium bicarbonate hydration before CTPA. Primary outcome was the increase in serum creatinine 48-96 h after CTPA. Secondary outcomes were the incidence of CI-AKI (creatinine increase > 25%/> 0.5 mg dL(-1) ), recovery of renal function, and the need for dialysis within 2 months after CTPA. Withholding hydration was considered non-inferior if the mean relative creatinine increase was ≤ 15% compared with sodium bicarbonate. Mean relative creatinine increase was -0.14% (interquartile range -15.1% to 12.0%) for withholding hydration and -0.32% (interquartile range -9.7% to 10.1%) for sodium bicarbonate (mean difference 0.19%, 95% confidence interval -5.88% to 6.25%, P-value non-inferiority < 0.001). CI-AKI occurred in 11 patients (8.1%): 6 (9.2%) were randomized to withholding hydration and 5 (7.1%) to sodium bicarbonate (relative risk 1.29, 95% confidence interval 0.41-4.03). Renal function recovered in 80.0% of CI-AKI patients within each group (relative risk 1.00, 95% confidence interval 0.54-1.86). None of the CI-AKI patients developed a need for dialysis. Our results suggest that preventive hydration could be safely withheld in CKD patients undergoing CTPA for suspected acute pulmonary embolism. This will facilitate management of these patients and prevents delay in diagnosis as well as unnecessary start of anticoagulant treatment while receiving volume expansion. © 2014 International Society on Thrombosis and Haemostasis.

  2. CT angiography versus conventional digital angiography in preoperative assessment for Chinese living kidney donors.

    PubMed

    Yap, Desmond Yat Hin; Chu, Ferdinand Siu Kay; Chu, Sai Man; Tam, Po Chor; Tam, Sidney; Chan, Tak Mao; Lai, Kar Neng; Tang, Sydney Chi Wai

    2010-01-01

    Computed tomography (CT) angiography is used for preoperative evaluation of living kidney donors, but its correlation with intraoperative findings during the transplant operation remains unknown. Between April 1997 and October 2008, 34 consecutive pairs of living kidney transplants were carried out. Conventional digital angiography was employed for the preoperative assessment in the first 19 pairs, and CT angiography in the subsequent 15 pairs. The radiological reports and operative findings during kidney harvest were carefully examined and compared. Among the 34 cases in our cohort, we found 9 early branching renal arteries (26.4%) and 6 double renal arteries (17%). Venous and ureteral anomalies were rare, with only 1 case (2.9%) of each. CT angiography offered excellent and equal accuracy (accuracy 100%) when compared with conventional digital angiography for renal arterial anatomy. CT angiography showed superior performance compared with conventional angiography in the domain of venous and collecting system anomalies (accuracy 100% vs. 94.7%, respectively). No contrast nephropathy or allergy was documented in our series. CT angiography showed excellent correlations with surgical findings in the Chinese population. It is associated with minimal risk of contrast nephropathy as well as lower cost and therefore should be adopted as the standard preoperative assessment of living kidney donors.

  3. [Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses].

    PubMed

    Gizewski, E R; Weber, R; Forsting, M

    2011-02-01

    Approximately 6 - 50% of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12%, and up to 19% in the case of high-grade IAS (≥ 70%). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7% at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40% depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    PubMed

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  5. Gamma Knife surgery for arteriovenous malformations in the brain: integration of time-resolved contrast-enhanced magnetic resonance angiography into dosimetry planning. Technical note.

    PubMed

    Taschner, Christian A; Le Thuc, Vianney; Reyns, Nicolas; Gieseke, Juergen; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2007-10-01

    The aim of this study was to develop an algorithm for the integration of time-resolved contrast-enhanced magnetic resonance (MR) angiography into dosimetry planning for Gamma Knife surgery (GKS) of arteriovenous malformations (AVMs) in the brain. Twelve patients harboring brain AVMs referred for GKS underwent intraarterial digital subtraction (DS) angiography and time-resolved MR angiography while wearing an externally applied cranial stereotactic frame. Time-resolved MR angiography was performed on a 1.5-tesla MR unit (Achieva, Philips Medical Systems) using contrast-enhanced 3D fast field echo sequencing with stochastic central k-space ordering. Postprocessing with interactive data language (Research Systems, Inc.) produced hybrid data sets containing dynamic angiographic information and the MR markers necessary for stereotactic transformation. Image files were sent to the Leksell GammaPlan system (Elekta) for dosimetry planning. Stereotactic transformation of the hybrid data sets containing the time-resolved MR angiography information with automatic detection of the MR markers was possible in all 12 cases. The stereotactic coordinates of vascular structures predefined from time-resolved MR angiography matched with DS angiography data in all cases. In 10 patients dosimetry planning could be performed based on time-resolved MR angiography data. In two patients, time-resolved MR angiography data alone were considered insufficient. The target volumes showed a notable shift of centers between modalities. Integration of time-resolved MR angiography data into the Leksell GammaPlan system for patients with brain AVMs is feasible. The proposed algorithm seems concise and sufficiently robust for clinical application. The quality of the time-resolved MR angiography sequencing needs further improvement.

  6. The evaluation of a formalized queue management system for coronary angiography waiting lists.

    PubMed

    Alter, D A; Newman, Alice M; Cohen, Eric A; Sykora, Kathy; Tu, Jack V

    2005-11-01

    Lengthy waiting lists for coronary angiography have been described in many health care systems worldwide. The extent to which formal queue management systems may improve the prioritization and survival of patients in the angiography queue is unknown. To prospectively evaluate the performance of a formal queue management system for patients awaiting coronary angiography in Ontario. The coronary angiography urgency scale, a formal queue management system developed in 1993 using a modified Delphi panel, allocates recommended maximum waiting times (RMWTs) in accordance with clinical necessity. By using a provincial clinical registry, 35,617 consecutive patients referred into the coronary angiography queue between April 1, 2001, and March 31, 2002, were prospectively tracked. Cox proportional hazards models were used to examined mortality risk across urgency after adjusting for additional clinical and comorbid factors. Good agreement was determined in urgency ratings between scores from the coronary angiography urgency scale and implicit physician judgement, which was obtained independently at the time of the index referral (weighted kappa = 0.49). The overall mortality in the queue was 0.3% (0.47%, 0.26% and 0.13% for urgent, semiurgent and elective patients, respectively). Urgency, as specified by the coronary angiography urgency scale, was the strongest predictor of death in the queue (P<0.001). However, when patients were censored according to their RMWTs, mortality was similar across different levels of urgency. Consequently, up to 18.5 deaths per 10,000 patients could have potentially been averted had patients been triaged and undergone coronary angiography within the RMWT as specified by the coronary angiography urgency scale. The incorporation of the coronary angiography urgency scale as a formal queue management system may decrease mortality in the coronary angiography queue. The authors recommend its implementation in health care systems where patients experience excessive waiting time delays for coronary angiography.

  7. Optical Coherence Tomography Angiography Features of Diabetic Retinopathy

    PubMed Central

    Hwang, Thomas S.; Jia, Yali; Gao, Simon S.; Bailey, Steven T.; Lauer, Andreas K.; Flaxel, Christina J.; Wilson, David J.; Huang, David

    2015-01-01

    Purpose To describe the optical coherence tomography (OCT) angiography features of diabetic retinopathy Methods Using a 70kHz OCT and the split-spectrum amplitude decorrelation angiography (SSADA) algorithm, 6 × 6 mm 3-dimensional angiograms of the macula of 4 patients with diabetic retinopathy were obtained and compared with fluorescein angiography (FA) for features catalogued by the Early Treatment of Diabetic Retinopathy Study. Results OCT angiography detected enlargement and distortion of the foveal avascular zone, retinal capillary dropout, and pruning of arteriolar branches. Areas of capillary loss obscured by fluorescein leakage on FA were more clearly defined on OCT angiography. Some areas of focal leakage on FA that were thought to be microaneurysms were found to be small tufts of neovascularization that extended above the inner limiting membrane. Conclusion OCT angiography does not show leakage, but can better delineate areas of capillary dropout and detect early retinal neovascularization. This new noninvasive angiography technology may be useful for routine surveillance of proliferative and ischemic changes in diabetic retinopathy. PMID:26308529

  8. Mixture models in diagnostic meta-analyses--clustering summary receiver operating characteristic curves accounted for heterogeneity and correlation.

    PubMed

    Schlattmann, Peter; Verba, Maryna; Dewey, Marc; Walther, Mario

    2015-01-01

    Bivariate linear and generalized linear random effects are frequently used to perform a diagnostic meta-analysis. The objective of this article was to apply a finite mixture model of bivariate normal distributions that can be used for the construction of componentwise summary receiver operating characteristic (sROC) curves. Bivariate linear random effects and a bivariate finite mixture model are used. The latter model is developed as an extension of a univariate finite mixture model. Two examples, computed tomography (CT) angiography for ruling out coronary artery disease and procalcitonin as a diagnostic marker for sepsis, are used to estimate mean sensitivity and mean specificity and to construct sROC curves. The suggested approach of a bivariate finite mixture model identifies two latent classes of diagnostic accuracy for the CT angiography example. Both classes show high sensitivity but mainly two different levels of specificity. For the procalcitonin example, this approach identifies three latent classes of diagnostic accuracy. Here, sensitivities and specificities are quite different as such that sensitivity increases with decreasing specificity. Additionally, the model is used to construct componentwise sROC curves and to classify individual studies. The proposed method offers an alternative approach to model between-study heterogeneity in a diagnostic meta-analysis. Furthermore, it is possible to construct sROC curves even if a positive correlation between sensitivity and specificity is present. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Effect of nicorandil on QT dispersion in patients with stable angina pectoris undergoing elective angioplasty: A triple-blind, randomized, placebo-controlled study

    PubMed Central

    Suleimani, Homa Fal; Eshraghi, Ali; Daloee, Mehdi Hasanzadeh; Hoseini, Sara; Nakhaee, Nima

    2017-01-01

    Background Nicorandil leads to the relaxation of fine vascular smooth muscle, and thus causes vasodilatation of major epicardial. Also, it has anti-arrhythmic and cardio-protective effects by improving reperfusion, and ultimately leads to a reduction in microvascular damage caused by percutaneous coronary intervention (PCI). Objective The aim of this study was to determine the effect of nicorandil on QT interval dispersion (QTd) in patients with stable angina pectoris during elective angioplasty. Methods This triple-blind and randomized clinical trial was performed on patients with stable angina pectoris, candidates for elective angiography referred to Imam Reza and Ghaem hospitals in Mashhad, Iran, between January and October 2016. The patients were randomly assigned to one of two groups receiving nicorandil (60 mg as 20 mg before and 40 mg after PCI) and placebo. All the patients underwent electrocardiography 12 hours before and 12 hours after PCI. The values of maximal corrected QT interval (QTc max) and QTd in these intervals, and the levels of changes in the QTd (QTd difference before angiography and after PCI) were compared between the two groups. Data were analyzed statistically using SPSS version 18 software via Chi-square and Independent-samples t-test. Results This study was performed on 90 patients (55 males and 35 females) with a mean age of 58.6±10.8 years, on two groups of 45 people. The two groups were matched for age, body mass index, cardiovascular risk factors and baseline testing. The QTd before angiography had no statistically significant difference between the patients of both groups (control: 77.7±17.1 vs. nicorandil: 80.7±14.2 ms; p=0.371). The QTd after PCI in the nicorandil group was lower than the control group (48.1±14.2 vs. 59.2±15.6 ms; p=0.000). The decrease rate in QTd had a statistically significant difference between the two groups (control: 18.9±11.0 vs. nicorandil: 33.5±9.5 ms; p=0.000). Conclusions The results of this study showed that oral administration of nicorandil around the PCI could further reduce QTd following PCI, compared to the control group. Trial registration The trial was registered at the Iranian Registry of Clinical Trials (http://www.irct.ir) with the Irct ID: IRCT2016120631159N1 Funding The authors received no financial support for the research, authorship, and/or publication of this article. PMID:28979725

  10. Comparison of CT angiography with conventional arterial angiography in aortoiliac occlusive disease.

    PubMed

    Tins, B; Oxtoby, J; Patel, S

    2001-03-01

    This study compared the results of conventional and CT angiography of the aortoiliac segment in 35 patients with occlusive disease. Disease severity was graded into five categories. Two assessors independently assessed the segment from the distal abdominal aorta to the proximal superficial femoral artery and a consensus was formed. There was interobserver agreement in 87% of segments for conventional angiography and in 78% for CT angiography. Comparison of the two modalities gave identical grading in 84% of segments. Dissimilar grading was found in 16%, with a roughly equal number of undergrading and overgrading. CT angiography has the advantages of being minimally invasive, requiring only an intravenous injection of contrast medium and imaging surrounding soft tissues. Multiplanar reconstruction aids the visualization of asymmetrical stenoses, and collateral blood supply is readily appreciated. However, CT angiography may fail to demonstrate short stenoses owing to limited z-axis resolution.

  11. Diagnostic Accuracy of Computed Tomography Angiography as Compared to Conventional Angiography in Patients Undergoing Noncoronary Cardiac Surgery

    PubMed Central

    Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal

    2016-01-01

    Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455

  12. [Indocyanine green infrared fluorescence angiography and vascular cast--preparation in experimental choroidal circulatory disturbance].

    PubMed

    Matsunaga, H; Andoh, A; Matsubara, T; Fukushima, I; Takahashi, K; Ohkuma, H; Uyama, M

    1996-03-01

    We performed experiments in 20 monkey eyes in order to clarify basic problems about interpretation of indocyanine green fluorescence angiography (ICG angiography). We severed the temporal group of posterior ciliary arteries to produce choroidal circulatory disturbance. ICG angiography was performed immediately, and 2 days, 4 days, and 2 weeks later. Following each ICG angiography, the eye was studied by plastic vascular cast technique with scanning electron microscopy. Immediately after occlusion, ICG angiography showed filling defect in the temporal choroidal hemisphere during the early phase. In the later phase, this area was gradually filled by the dye from choroidal arteries in the nasal hemisphere and the anterior ciliary arteries. Vascular cast preparations showed filling defect in the temporal choroidal hemisphere, corresponding with the early ICG angiogaphic findings. Both filling delay in ICG angiography and filling defect in vascular casts improved daily after occlusion. Two weeks after occlusion, The area of choroidal infarct temporal to the macula turned into chorioretinal atrophy. This area showed hypofluorescence in the early-phase ICG angiography and filling defect of the choriocapillaris in plastic casts. The early-phase ICG angiographic findings thus corresponded well with observations of vascular casts. We conclude that ICG angiography correctly reflects the actual circulatory disturbances in the choroid.

  13. Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deutschmann, Hannes A.; Schoellnast, Helmut; Portugaller, Horst R.

    2006-10-15

    Purpose. To compare the diagnostic accuracy of contrast-enhanced (CE) three-dimensional (3D) moving-table magnetic resonance (MR) angiography with that of selective digital subtraction angiography (DSA) for routine clinical investigation in patients with peripheral arterial occlusive disease. Methods. Thirty-eight patients underwent CE 3D moving-table MR angiography of the pelvic and peripheral arteries. A commercially available large-field-of-view adapter and a dedicated peripheral vascular phased-array coil were used. MR angiograms were evaluated for grade of arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of selective DSA. Results. Two hundred and twenty-six arterial segments inmore » 38 patients were evaluated by both selective DSA and MR angiography. No complications related to MR angiography were observed. There was agreement in stenosis classification in 204 (90.3%) segments; MR angiography overgraded 16 (7%) segments and undergraded 6 (2.7%) segments. Compared with selective DSA, MR angiography provided high sensitivity and specificity and excellent interobserver agreement for detection of severe stenosis (97% and 95%, {kappa} = 0.9 {+-} 0.03) and moderate stenosis (96.5% and 94.3%, {kappa} = 0.9 {+-} 0.03). Conclusion. Compared with selective DSA, moving-table MR angiography proved to be an accurate, noninvasive method for evaluation of peripheral arterial occlusive disease and may thus serve as an alternative to DSA in clinical routine.« less

  14. The Predictive Value of Pulse Oximeters for Pulse Improvement after Angiography in Infants and Children

    PubMed Central

    Alipour, Mohammad-Reza; Rastegar, Mazyar; Ghaderian, Mehdi; Namayandeh, Seyedeh-Mahdieh; Faraji, Reza; Pezeshkpour, Zohreh

    2016-01-01

    Background Information from pulse oximeter waves confirms the presence of a pulse and helps obtain waves from tissue when the supplying artery is not readily accessible. Objectives This study determined the predictive value of pulse oximeters for detecting improved arterial pulses after angiography. Patients and Methods This cross-sectional, multi-center study included 467 4-day-old to 12-year-old patients and was conducted from January 2012 to January 2016. Angiographies were performed on 12-year-old or younger children for various medical reasons using venous, arterial, or both types of paths. The posterior malleolar or dorsalis pedis were palpated in punctured lower extremities. In the absence of a pulse, pulse oximetry was performed to identify pulse curves at 1 hour, 6 hours, and 12 hours after each angiography. Results Pulse oximetry displayed the pulses of 319 patients immediately following each angiography. Of these, 262 patients had palpable pulses at 6 hours after angiography (P < 0.0001), while 57 patients had no palpable pulse. Of these 57 patients, 15 had no palpable pulse at 12 hours after angiography (P < 0.0001). The odds of pulse improvement in children 6 hours after catheter angiography were 76% for the arterial path, 90% for the venous path, and 83.2% for both paths. At 12 hours after catheter angiography, these values increased to 91.6% for the arterial path, 100% for the venous path, and 95.9% for both paths. Conclusions The pulse oximeter can display the pulse curve immediately (1 hour) after angiography and indicate pulse improvement at 12 hours maximally following an angiography. In this case, heparin alone may be used instead of thrombolytic agents. PMID:28203338

  15. Angiography Before Posterior Mediastinal Tumor Resection: Selection Criteria and Patient Outcomes.

    PubMed

    Madariaga, Maria Lucia; Borges, Lawrence F; Rabinov, James D; Chang, David C; Lanuti, Michael; Mathisen, Douglas J; Gaissert, Henning A

    2018-04-01

    Resection of posterior mediastinal tumors may be complicated by bleeding or neurologic injury. Preoperative spinal angiography of mediastinal tumors has been underreported or not commonly practiced. This study evaluated the selection criteria and outcomes of patients with posterior mediastinal tumors who underwent preoperative angiography and embolization. This was a single-institution retrospective study of patients with posterior mediastinal tumors from 2002 to 2016. Multilevel spinal angiography was performed, with or without selective arterial embolization of vascular supply, in patients selected by thoracic or neurologic surgeons. Ten of 87 patients (11%) with posterior mediastinal tumors underwent preoperative angiography. A mean of 11 arteries (range, 2 to 25) were studied. Embolization in 7 of 10 patients successfully occluded 1 to 3 arteries. There was no significant difference in age, sex, body mass index, American Society of Anesthesiologists Physical Status Classification, operative time, operative blood loss, complications, or death between patients with or without angiography. Patients who underwent angiography had larger tumors (1,490 vs 97 cm 3 , p < 0.0001), involvement of the neuroforamen (44% vs 10%, p < 0.05), and a longer hospital stay (9 vs 4.5 days, p < 0.05). Angiography was complicated in 1 patient by vocal cord ulceration after intubation of a tumor-compressed trachea. Shared blood supply between the tumor and the spinal cord precluded embolization and tumor resection in 1 patient. Use of angiography increased over time. Selective preoperative angiography for evaluation of posterior mediastinal tumors identifies arterial variations, threatened spinal arteries, and targets for embolization. The specific role of angiography and embolization requires further investigation to standardize indications and protocols for the number of arteries examined. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Can Radiation Dose Be Reduced and Image Quality Improved With 80-kV and Dual-Phase Scanning of the Lower Extremities With 64-Slice Computed Tomography Angiography?

    PubMed

    Zhou, Yunfeng; Wang, Juan; Dassarath, Meera; Wang, Minhong; Zhang, Qiang; Xiong, Yuwei; Yuan, Quan

    2015-01-01

    To prospectively compare the new computed tomographic angiography (CTA) protocol (NCP) using 80-kV and dual-phase scanning with the routine CTA protocol (RCP) using 120-kV and single-phase scanning in patients with peripheral arterial disease. A total of 60 patients were randomized to undergo the NCP (30 patients) or RCP (30 patients) scan. We compared the arterial attenuation values, overriding of the contrast bolus, signal-to-noise ratio, and radiation dose between 2 groups. The occurrence rate of contrast bolus overriding was not statistically significant (P = 0.69). The average arterial attenuation value in the NCP group was significantly higher (P < 0.05) than that in the RCP group. The radiation dose in the RCP group was significantly higher (P < 0.001) than that in the NCP group. The mean signal-to-noise ratio in the NCP group was significantly lower (P < 0.001). Sixty-four-slice CTA with the NCP can significantly reduce the radiation dose and improve the arterial enhancement and calf arteries imaging.

  17. Quality of life after acute myocardial infarction among patients treated at sites with and without on-site availability of angiography.

    PubMed

    Pilote, Louise; Lauzon, Claude; Huynh, Thao; Dion, Danielle; Roux, René; Racine, Normand; Carignan, Suzanne; Diodati, Jean G; Lévesque, Claude; Charbonneau, François; Pouliot, Joël; Joseph, Lawrence; Eisenberg, Mark J

    2002-03-11

    Previous studies have compared the treatment and outcome of patients with acute myocardial infarction (AMI) admitted at sites with and without availability of angiography. Although mortality rates do not differ, it is unknown if quality of life (QOL) and functional status differ. We measured QOL and functional status in patients with AMI treated within Québec at 5 sites with (n = 253) and 5 sites without (n = 334) angiography. At admission, clinical characteristics, complication rates, and baseline measures of QOL and functional status were similar at sites with and without angiography. During hospitalization, patients treated at sites with angiography were more likely to undergo an invasive cardiac procedure than patients admitted at sites without angiography (angiography, 63% vs 26%; percutaneous transluminal coronary angioplasty, 33% vs 13%; and coronary artery bypass graft, 12% vs 5%). At 30 days and 6 months after AMI, QOL was slightly superior at sites with angiography, but by 1 year, most measures of QOL were back to baseline at both types of sites and were similar between the 2 groups. At 6 months, most standard health-related QOL components were similar; only physical and emotional role limitations were higher at sites with angiography. Return to work occurred earlier (at 30 days, 23% vs 12%), and a lower proportion of patients was readmitted for angina (within 1 year after AMI, 12% vs 18%) at sites with angiography. In the early post-AMI period, the QOL of patients admitted at sites with angiography was higher than that of patients admitted at sites without angiography. However, by 1 year, the QOL and functional status of patients was similar in both groups. Differences in QOL were greatest when differences in treatment were greatest, lending support to a positive albeit small association between an early invasive approach to post-AMI care and improved QOL.

  18. Three-dimensional volume-rendering technique in the angiographic follow-up of intracranial aneurysms embolized with coils.

    PubMed

    Zhou, Bing; Li, Ming-Hua; Wang, Wu; Xu, Hao-Wen; Cheng, Yong-De; Wang, Jue

    2010-03-01

    The authors conducted a study to evaluate the advantages of a 3D volume-rendering technique (VRT) in follow-up digital subtraction (DS) angiography of coil-embolized intracranial aneurysms. One hundred nine patients with 121 intracranial aneurysms underwent endovascular coil embolization and at least 1 follow-up DS angiography session at the authors' institution. Two neuroradiologists independently evaluated the conventional 2D DS angiograms, rotational angiograms, and 3D VRT images obtained at the interventional procedures and DS angiography follow-up. If multiple follow-up sessions were performed, the final follow-up was mainly considered. The authors compared the 3 techniques for their ability to detect aneurysm remnants (including aneurysm neck and sac remnants) and parent artery stenosis based on the angiographic follow-up. The Kruskal-Wallis test was used for group comparisons, and the kappa test was used to measure interobserver agreement. Statistical analyses were performed using commercially available software. There was a high statistical significance among 2D DS angiography, rotational angiography, and 3D VRT results (X(2) = 9.9613, p = 0.0069) when detecting an aneurysm remnant. Further comparisons disclosed a statistical significance between 3D VRT and rotational angiography (X(2) = 4.9754, p = 0.0257); a high statistical significance between 3D VRT and 2D DS angiography (X(2) = 8.9169, p = 0.0028); and no significant difference between rotational angiography and 2D DS angiography (X(2) = 0.5648, p = 0.4523). There was no statistical significance among the 3 techniques when detecting parent artery stenosis (X(2) = 2.5164, p = 0.2842). One case, in which parent artery stenosis was diagnosed by 2D DS angiography and rotational angiography, was excluded by 3D VRT following observations of multiple views. The kappa test showed good agreement between the 2 observers. The 3D VRT is more sensitive in detecting aneurysm remnants than 2D DS angiography and rotational angiography and is helpful for identifying parent artery stenosis. The authors recommend this technique for the angiographic follow-up of patients with coil-embolized aneurysms.

  19. Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials

    PubMed Central

    Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia

    2018-01-01

    Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or single photon emission computed tomography-myocardial perfusion imaging resulted in fewer downstream tests than coronary computed tomographic angiography (0.24 (0.08 to 0.74) and 0.57 (0.37 to 0.87), respectively). However, exercise electrocardiograms yielded the highest downstream testing rate. Estimates for death and myocardial infarction were imprecise without clear discrimination between strategies. Conclusions For patients with low risk acute coronary syndrome, an initial diagnostic strategy of stress echocardiography or cardiovascular magnetic resonance is associated with fewer referrals for invasive coronary angiography and revascularisation procedures than non-invasive anatomical testing, without apparent impact on the future risk of myocardial infarction. For suspected stable coronary artery disease, there was no clear discrimination between diagnostic strategies regarding the subsequent need for invasive coronary angiography, and differences in the risk of myocardial infarction cannot be ruled out. Systematic review registration PROSPERO registry no CRD42016049442. PMID:29467161

  20. Does CT Angiography Matter for Patients with Cervical Spine Injuries?

    PubMed

    Hagedorn, John C; Emery, Sanford E; France, John C; Daffner, Scott D

    2014-06-04

    Cervical injury can be associated with vertebral artery injury. This study was performed to determine the impact of computed tomography (CT) angiography of the head and neck on planning treatment of cervical spine fracture, if these tests were ordered appropriately, and to estimate cost and associated exposure to radiation and contrast medium. This retrospective review included all patients who underwent CT of the cervical spine and CT angiography of the head and neck from January 2010 to August 2011 at one institution. Patients were divided into those with and those without cervical spine fracture seen on CT of the cervical spine. We determined if the CT angiography of the head and neck was positive for vascular injury in the patients with a cervical fracture. Vascular injury treatment and alterations in surgical fracture treatment due to positive CT angiography of the head and neck were recorded. A scan was deemed appropriate if it had been ordered per established institutional protocol. Of the 381 patients who underwent CT angiography of the head and neck, 126 had a cervical injury. Sixteen of the CT angiography studies were appropriately ordered for non-spinal indications, and twenty-three were inappropriately ordered. The CT angiography was positive for one patient for whom the imaging was off protocol and one for whom the indication was non-spinal. Nineteen patients had positive CT angiography of the head and neck; no patient underwent surgical intervention for a vascular lesion. Eleven patients underwent surgical intervention for a cervical fracture; the operative plan was changed because of vascular injury in one case. The CT angiography was positive for eleven of forty-eight patients who had sustained a C2 fracture; this group accounted for eleven of the nineteen positive CT angiography studies. Noncontiguous injuries occurred in nineteen patients; three had positive CT angiography of the head and neck. The approximate charge for the CT angiography was $3925, radiation exposure was approximately 4000 mGy/cm, and contrast-medium load was approximately 100 mL. Positive CT angiography of the head and neck rarely altered surgical treatment of cervical spine injuries. This study supports the findings in the literature that C1-C3 spine injuries have an increased association with vertebral artery injury. CT angiography of the head and neck ordered off protocol had a low likelihood of being positive. Strict adherence to protocols for CT angiography of the head and neck can reduce costs and decrease unnecessary exposure to radiation and contrast medium. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  1. 64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access.

    PubMed

    Wasinrat, Jitladda; Siriapisith, Thanongchai; Thamtorawat, Somrach; Tongdee, Trongtum

    2011-01-01

    To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant (<50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction.

  2. CT Angiography after 20 Years

    PubMed Central

    Rubin, Geoffrey D.; Leipsic, Jonathon; Schoepf, U. Joseph; Fleischmann, Dominik; Napel, Sandy

    2015-01-01

    Through a marriage of spiral computed tomography (CT) and graphical volumetric image processing, CT angiography was born 20 years ago. Fueled by a series of technical innovations in CT and image processing, over the next 5–15 years, CT angiography toppled conventional angiography, the undisputed diagnostic reference standard for vascular disease for the prior 70 years, as the preferred modality for the diagnosis and characterization of most cardiovascular abnormalities. This review recounts the evolution of CT angiography from its development and early challenges to a maturing modality that has provided unique insights into cardiovascular disease characterization and management. Selected clinical challenges, which include acute aortic syndromes, peripheral vascular disease, aortic stent-graft and transcatheter aortic valve assessment, and coronary artery disease, are presented as contrasting examples of how CT angiography is changing our approach to cardiovascular disease diagnosis and management. Finally, the recently introduced capabilities for multispectral imaging, tissue perfusion imaging, and radiation dose reduction through iterative reconstruction are explored with consideration toward the continued refinement and advancement of CT angiography. PMID:24848958

  3. Tricuspid regurgitation by radionuclide angiography and contrast right ventriculography: a preliminary observation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumia, F.J.; Patil, A.; Germon, P.A.

    In a retrospective study correlating the degree of tricuspid regurgitation seen on first-pass radionuclide angiography with that seen on contrast right ventriculography in 51 patients, ten had no tricuspid regurgitation by contrast ventriculography, whereas by radionuclide angiography nine had no regurgitation and one had minimal regurgitation. Of eight patients with minimal tricuspid regurgitation by contrast ventriculography, five had minimal regurgitation by nuclide angiography and three had no regurgitation. Of the 11 patients with mild to moderate tricuspid regurgitation by contrast studies, ten had mild to moderate regurgitation and one had severe regurgitation by nuclide angiography. Of 22 patients with moderatemore » to severe tricuspid regurgitation by contrast studies, 15 had moderate to severe regurgitation and seven had mild to moderate regurgitation by nuclear angiography. In this preliminary study comparing radionuclide angiography with contrast right ventriculography, there were three false-negative and one false-positive nuclide angiograms, giving a sensitivity of 93% and a specificity of 90%.« less

  4. [Effects of Aromatherapy on Stress Responses, Autonomic Nervous System Activity and Blood Pressure in the Patients Undergoing Coronary Angiography: A Non-Randomized Controlled Trial].

    PubMed

    Song, Eun Jeong; Lee, Mi Young

    2018-02-01

    The purpose of this study was to examine the effects of aromatherapy on stress responses, autonomic nervous system (ANS) activity, and blood pressure in patients hospitalized to receive coronary angiography (CAG). A non-equivalent control group with a pretest-posttest design was used. The subjects were patients admitted to the day angiography room to receive CAG at E University Hospital (34 in the experimental group and 30 in the control group). The experimental group treatment was inhalation of the aroma oil blended with lavender, ylang-ylang, and neroli at a ratio of 4:2:1 twice before and after CAG. The measurements of stress index, ANS activity, and blood pressure were performed 5 times as follows: at admission, at pre-CAG after treatment I, at post-CAG, 2 hours after treatment II, and 4 hours after treatment II. The data were analyzed using the Mann-Whitney U Test and repeated-measures analysis of variance. Significant interactions in the high frequency of ANS (F=5.58, p=.005) were observed between group and time. Stress index (z=2.14, p=.016), systolic blood pressure (z=4.14, p<.005), and diastolic blood pressure (z=3.28, p=.001) were significantly different between the experimental and control groups after 4 hours of treatment II. The findings showed that aromatherapy was not effective before CAG, but was effective after CAG. Therefore, aromatherapy can be used as a nursing intervention for patients receiving CAG. © 2018 Korean Society of Nursing Science.

  5. PROMISE of Coronary CT Angiography: Precise and Accurate Diagnosis and Prognosis in Coronary Artery Disease.

    PubMed

    Thomas, Dustin M; Branch, Kelley R; Cury, Ricardo C

    2016-04-01

    Coronary computed tomography angiography (CCTA) is a rapidly growing and powerful diagnostic test that offers a great deal of precision with respect to diagnosing coronary artery disease (CAD). Guideline statements for patients with stable ischemic heart disease have recommended CCTA for only a limited portion of intermediate-risk patients who have relative or absolute contraindications for exercise or vasodilator stress testing. The publication of two large, prospective randomized clinical trials, the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial are likely to expand these indications. These new data from large trials, in addition to other studies, show that CCTA is highly sensitive for the detection of CAD, identifies high-risk patients for cardiac events based on extent or plaque morphology of CAD that would not be identified by other noninvasive means, and provides significantly greater diagnostic certainty for proper treatment, including referral for invasive coronary angiography with revascularization more appropriately. Superior diagnostic accuracy and prognostic data with CCTA, when compared with other functional stress tests, may result in a reduction in unnecessary downstream testing and cost savings. In addition, newer CCTA applications hold the promise of providing a complete evaluation of a patient's coronary anatomy as well as a per-vessel ischemic evaluation. This review focuses on the interval knowledge obtained from newer data on CCTA in patients with stable ischemic heart disease, primarily focusing on the contributions of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial.

  6. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design.

    PubMed

    Diletti, Roberto; Serruys, Patrick W; Farooq, Vasim; Sudhir, Krishnankutty; Dorange, Cecile; Miquel-Hebert, Karine; Veldhof, Susan; Rapoza, Richard; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Chevalier, Bernard

    2012-11-01

    Currently, no data are available on the direct comparison between the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) and conventional metallic drug-eluting stents. The ABSORB II study is a randomized, active-controlled, single-blinded, multicenter clinical trial aiming to compare the second-generation Absorb BVS with the XIENCE everolimus-eluting metallic stent. Approximately 501 subjects will be enrolled on a 2:1 randomization basis (Absorb BVS/XIENCE stent) in approximately 40 investigational sites across Europe and New Zealand. Treated lesions will be up to 2 de novo native coronary artery lesions, each located in different major epicardial vessels, all with an angiographic maximal luminal diameter between 2.25 and 3.8 mm as estimated by online quantitative coronary angiography (QCA) and a lesion length of ≤48 mm. Clinical follow-up is planned at 30 and 180 days and at 1, 2, and 3 years. All subjects will undergo coronary angiography, intravascular ultrasound (IVUS) and IVUS-virtual histology at baseline (pre-device and post-device implantation) and at 2-year angiographic follow-up. The primary end point is superiority of the Absorb BVS vs XIENCE stent in terms of vasomotor reactivity of the treated segment at 2 years, defined as the QCA quantified change in the mean lumen diameter prenitrate and postnitrate administration. The coprimary end point is the noninferiority (reflex to superiority) of the QCA-derived minimum lumen diameter at 2 years postnitrate minus minimum lumen diameter postprocedure postnitrate by QCA. In addition, all subjects allocated to the Absorb BVS group will undergo multislice computed tomography imaging at 3 years. The ABSORB II randomized controlled trial (ClinicalTrials.gov NCT01425281) is designed to compare the safety, efficacy, and performance of Absorb BVS against the XIENCE everolimus-eluting stent in the treatment of de novo native coronary artery lesions. Copyright © 2012 Mosby, Inc. All rights reserved.

  7. Coronary artery calcium scoring does not add prognostic value to standard 64-section CT angiography protocol in low-risk patients suspected of having coronary artery disease.

    PubMed

    Kwon, Sung Woo; Kim, Young Jin; Shim, Jaemin; Sung, Ji Min; Han, Mi Eun; Kang, Dong Won; Kim, Ji-Ye; Choi, Byoung Wook; Chang, Hyuk-Jae

    2011-04-01

    To evaluate the prognostic outcome of cardiac computed tomography (CT) for prediction of major adverse cardiac events (MACEs) in low-risk patients suspected of having coronary artery disease (CAD) and to explore the differential prognostic values of coronary artery calcium (CAC) scoring and coronary CT angiography. Institutional review committee approval and informed consent were obtained. In 4338 patients who underwent 64-section CT for evaluation of suspected CAD, both CAC scoring and CT angiography were concurrently performed by using standard scanning protocols. Follow-up clinical outcome data regarding composite MACEs were procured. Multivariable Cox proportional hazards models were developed to predict MACEs. Risk-adjusted models incorporated traditional risk factors for CAC scoring and coronary CT angiography. During the mean follow-up of 828 days ± 380, there were 105 MACEs, for an event rate of 3%. The presence of obstructive CAD at coronary CT angiography had independent prognostic value, which escalated according to the number of stenosed vessels (P < .001). In the receiver operating characteristic curve (ROC) analysis, the superiority of coronary CT angiography to CAC scoring was demonstrated by a significantly greater area under the ROC curve (AUC) (0.892 vs 0.810, P < .001), whereas no significant incremental value for the addition of CAC scoring to coronary CT angiography was established (AUC = 0.892 for coronary CT angiography alone vs 0.902 with addition of CAC scoring, P = .198). Coronary CT angiography is better than CAC scoring in predicting MACEs in low-risk patients suspected of having CAD. Furthermore, the current standard multisection CT protocol (coronary CT angiography combined with CAC scoring) has no incremental prognostic value compared with coronary CT angiography alone. Therefore, in terms of determining prognosis, CAC scoring may no longer need to be incorporated in the cardiac CT protocol in this population. © RSNA, 2011.

  8. Relationship between the Self-Rating Anxiety Scale score and the success rate of 64-slice computed tomography coronary angiography.

    PubMed

    Li, Hui; Jin, Dan; Qiao, Fang; Chen, Jianchang; Gong, Jianping

    Computed tomography coronary angiography, a key method for obtaining coronary artery images, is widely used to screen for coronary artery diseases due to its noninvasive nature. In China, 64-slice computed tomography systems are now the most common models. As factors that directly affect computed tomography performance, heart rate and rhythm control are regulated by the autonomic nervous system and are highly related to the emotional state of the patient. The aim of this prospective study is to use a pre-computed tomography scan Self-Rating Anxiety Scale assessment to analyze the effects of tension and anxiety on computed tomography coronary angiography success. Subjects aged 18-85 years who were planned to undergo computed tomography coronary angiography were enrolled; 1 to 2 h before the computed tomography scan, basic patient data (gender, age, heart rate at rest, and family history) and Self-Rating Anxiety Scale score were obtained. The same group of imaging department doctors, technicians, and nurses performed computed tomography coronary angiography for all the enrolled subjects and observed whether those subjects could finish the computed tomography coronary angiography scan and provide clear, diagnostically valuable images. Participants were divided into successful (obtained diagnostically useful coronary images) and unsuccessful groups. Basic data and Self-Rating Anxiety Scale scores were compared between the groups. The Self-Rating Anxiety Scale standard score of the successful group was lower than that of the unsuccessful group (P = 0.001). As the Self-Rating Anxiety Scale standard score rose, the success rate of computed tomography coronary angiography decreased. The Self-Rating Anxiety Scale score has a negative relationship with computed tomography coronary angiography success. Anxiety can be a disadvantage in computed tomography coronary angiography examination. The pre-computed tomography coronary angiography scan Self-Rating Anxiety Scale score may be a useful tool for assessing whether a computed tomography coronary angiography scan will be successful or not. © The Author(s) 2015.

  9. The Supraclavicular Artery Perforator Flap: A Comparative Study of Imaging Techniques Used in Preoperative Mapping.

    PubMed

    Sheriff, Hemin Oathman; Mahmood, Kawa Abdullah; Hamawandi, Nzar; Mirza, Aram Jamal; Hawas, Jawad; Moreno, Esther Granell; Clavero, Juan Antonio; Hankins, Christopher; Masia, Jaume

    2018-05-18

     The supraclavicular artery flap is an excellent flap for head and neck reconstruction. The aim of this study is to assess imaging techniques to define the precise vascular boundaries of this flap.  Six imaging techniques were used for supraclavicular artery mapping in 65 cases; handheld Doppler, triplex ultrasound, computed tomography angiography, magnetic resonance angiography, digital subtraction angiography, and indocyanine green angiography. We checked the site of the perforators, the course of a supraclavicular artery, and anatomical mapping of the supraclavicular artery.  Handheld Doppler identified perforators' sites in 80% of the cases but showed no results for the course of the vessel. Triplex ultrasound identified the site of perforators in 52.9%, and partial mapping of the course of a supraclavicular artery in 64.7% of the cases. Computerized tomography angiography showed the site of perforators in 60%, and the course of supraclavicular artery completely in 45%, and partially in an additional 30%of the cases examined. Magnetic resonance angiography showed negative results for all parameters. Digital subtraction angiography showed the partial course of a supraclavicular artery in 62.5%, but showed no perforators. Indocyanine green angiography showed the site of perforators in 60% and a partial course of supraclavicular artery distal to perforators in 60%.Anatomical mapping of the vessel was possible with computerized tomography angiogram completely in 45%, and partially in 30%, and was also possible with indocyanine green angiography partially in 60%.  Computerized tomography angiography showed best results in the mapping of the supraclavicular artery, but with an inability to define the perforator perfusion territories, and also with risks of irradiation, while indocyanine green angiography is a good alternative as it could precisely map the superficial course of the artery and angiosomes, with no radiation exposure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. CT angiography - abdomen and pelvis

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007674.htm CT angiography - abdomen and pelvis To use the sharing features on this page, please enable JavaScript. CT angiography combines a CT scan with the injection ...

  11. CT angiography - arms and legs

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007675.htm CT angiography - arms and legs To use the sharing features on this page, please enable JavaScript. CT angiography combines a CT scan with the injection ...

  12. CT angiography - head and neck

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/007677.htm CT angiography - head and neck To use the sharing features on this page, please enable JavaScript. CT angiography (CTA) combines a CT scan with the ...

  13. CAPILLARY NETWORK ANOMALIES IN BRANCH RETINAL VEIN OCCLUSION ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Rispoli, Marco; Savastano, Maria Cristina; Lumbroso, Bruno

    2015-11-01

    To analyze the foveal microvasculature features in eyes with branch retinal vein occlusion (BRVO) using optical coherence tomography angiography based on split spectrum amplitude decorrelation angiography technology. A total of 10 BRVO eyes (mean age 64.2 ± 8.02 range between 52 years and 76 years) were evaluated by optical coherence tomography angiography (XR-Avanti; Optovue). The macular angiography scan protocol covered a 3 mm × 3 mm area. The focus of angiography analysis were two retinal layers: superficial vascular network and deep vascular network. The following vascular morphological congestion parameters were assessed in the vein occlusion area in both the superficial and deep networks: foveal avascular zone enlargement, capillary non-perfusion occurrence, microvascular abnormalities appearance, and vascular congestion signs. Image analyses were performed by 2 masked observers and interobserver agreement of image analyses was 0.90 (κ = 0.225, P < 0.01). In both superficial and deep network of BRVO, a decrease in capillary density with foveal avascular zone enlargement, capillary non-perfusion occurrence, and microvascular abnormalities appearance was observed (P < 0.01). The deep network showed the main vascular congestion at the boundary between healthy and nonperfused retina. Optical coherence tomography angiography in BRVO allows to detect foveal avascular zone enlargement, capillary nonperfusion, microvascular abnormalities, and vascular congestion signs both in the superficial and deep capillary network in all eyes. Optical coherence tomography angiography technology is a potential clinical tool for BRVO diagnosis and follow-up, providing stratigraphic vascular details that have not been previously observed by standard fluorescein angiography. The normal retinal vascular nets and areas of nonperfusion and congestion can be identified at various retinal levels. Optical coherence tomography angiography provides noninvasive images of the retinal capillaries and vascular networks.

  14. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents.

    PubMed

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia; Thoeny, Harriet C

    2010-03-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 +/- 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m(2)). Mean eGFR pre-angiography was 26 ml/min/1.73 m(2) and 33 ml/min/1.73 m(2) post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO(2) angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients.

  15. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    PubMed

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; P<.001). Mean fluoroscopy times were higher in the cine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; P<.01). Mean contrast use was higher in the cine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; P<.001). Mean value of Crombach's alpha was not statistically different between visual estimates of three operators between cine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  16. Electrocardiograph-gated single photon emission computed tomography radionuclide angiography presents good interstudy reproducibility for the quantification of global systolic right ventricular function.

    PubMed

    Daou, Doumit; Coaguila, Carlos; Vilain, Didier

    2007-05-01

    Electrocardiograph-gated single photon emission computed tomography (SPECT) radionuclide angiography provides accurate measurement of right ventricular ejection fraction and end-diastolic and end-systolic volumes. In this study, we report the interstudy precision and reliability of SPECT radionuclide angiography for the measurement of global systolic right ventricular function using two, three-dimensional volume processing methods (SPECT-QBS, SPECT-35%). These were compared with equilibrium planar radionuclide angiography. Ten patients with chronic coronary artery disease having two SPECT and planar radionuclide angiography acquisitions were included. For the right ventricular ejection fraction, end-diastolic volume and end-systolic volume, the interstudy precision and reliability were better with SPECT-35% than with SPECT-QBS. The sample sizes needed to objectify a change in right ventricular volumes or ejection fraction were lower with SPECT-35% than with SPECT-QBS. The interstudy precision and reliability of SPECT-35% and SPECT-QBS for the right ventricle were better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography on the same population. SPECT-35% and SPECT-QBS present good interstudy precision and reliability for right ventricular function, with the results favouring the use of SPECT-35%. The results are better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography. They need to be confirmed in a larger population.

  17. Preoperative evaluation of hilar vessel anatomy with 3-D computerized tomography in living kidney donors.

    PubMed

    Tombul, S T; Aki, F T; Gunay, M; Inci, K; Hazirolan, T; Karcaaltincaba, M; Erkan, I; Bakkaloglu, A; Yasavul, U; Bakkaloglu, M

    2008-01-01

    Digital subtract angiography is the gold standard for anatomic assessment of renal vasculature for living renal donors. However, multidetector-row computerized tomography (MDCT) is less invasive than digital subtract angiography and provides information of kidney stones and other intra-abdominal organs. In this study, preoperative MDCT angiography results were compared with the peroperative findings to evaluate the accuracy of MDCT for the evaluation of renal anatomy. From December 2002 to May 2007, all 60 consecutive living kidney donors were evaluated with MDCT angiography preoperatively. We reported the number and origin of renal arteries, presence of early branching arteries, and any intrinsic renal artery disease. Renal venous anatomy was evaluated for the presence of accessory, retroaortic, and circumaortic veins using venous phase axial images. The calyces and ureters were assessed with delayed topograms. The results of the MDCT angiography were compared with the peroperative findings. A total of 67 renal arteries were seen peroperatively in 60 renal units. Preoperative MDCT angiography detected 64 of them. The two arteries not detected by MDCT had diameters less than 3 mm. Anatomic variations were present in nine veins, five of which were detected by CT angiography. Sensitivity of MDCT angiography for arteries and veins was 95% and 93%, respectively. Positive predictive values were 100% for both arteries and veins. MDCT angiography offers a less invasive, rapid, and accurate preoperative investigation modality for vascular anatomy in living kidney donors. It also provides sufficient information about extrarenal anatomy important for donor surgery.

  18. Pulmonary Thromboembolism: Evaluation By Intravenous Angiography

    NASA Astrophysics Data System (ADS)

    Pond, Gerald D.; Cook, Glenn C.; Woolfenden, James M.; Dodge, Russell R.

    1981-11-01

    Using perfusion lung scans as a guide, digital video subtraction angiography of the pulmonary arteries was performed in human subjects suspected of having pulmonary embolism. Dogs were employed as a pulmonary embolism model and both routine pulmonary angiography and intravenous pulmonary angiograms were obtained for comparison purposes. We have shown by our preliminary results that the technique is extremely promising as a safe and accurate alternative to routine pulmonary angiography in selected patients.

  19. CT angiography of the renal arteries and veins: normal anatomy and variants.

    PubMed

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  20. Renal denervation using catheter-based radiofrequency ablation with temperature control: renovascular safety profile and underlying mechanisms in a hypertensive canine model.

    PubMed

    Li, Huijie; Yu, Hang; Zeng, Chunyu; Fang, Yuqiang; He, Duofen; Zhang, Xiaoqun; Wen, Chunlan; Yang, Chengming

    2015-01-01

    Renal denervation is a novel method for hypertension treatment. In this study, we aimed to investigate the safety and efficacy of radiofrequency ablation (RFA) at ablation temperatures of 45 °C or 50 °C and its possible mechanisms. A hypertensive canine model was established by abdominal aortic constriction in 20 healthy hybrid dogs. These dogs were then randomly assigned to the treatment and the control groups, with dogs in the treatment group further randomly assigned to receive RFA at ablation temperatures of 45 °C or 50 °C. In the treatment group, RFA was performed at 1 month after modeling; renal angiography was performed at 2 months after ablation. The arterial vessels of the dogs were examined histologically with hematoxylin and eosin staining. Changes in blood pressure in the foreleg and whole-body norepinephrine spillover rate were also assessed. No arterial stenosis, dissection, thrombosis or other abnormalities were detected in the treated vessels by renal angiography, yet histology results showed minimal to mild renal arterial injury. Renal denervation resulted in a marked decrease in the whole-body norepinephrine spillover rate (p < 0.05) in addition to significantly reducing blood pressure (p < 0.05), with no significant differences detected between the 45 °C and 50 °C subgroups for both (p > 0.05). Renal denervation can be performed without acute major adverse events, using catheter-based RFA with temperature control. The procedure was feasible in reducing blood pressure by at least partially inhibiting sympathetic drive and systemic sympathetic outflow.

  1. Highly flexible nitinol mesh to encase aortocoronary saphenous vein grafts: first clinical experiences and angiographic results nine months postoperatively.

    PubMed

    Schoettler, Jan; Jussli-Melchers, Jill; Grothusen, Christina; Stracke, Lars; Schoeneich, Felix; Stohn, Simon; Hoffmann, Grischa; Cremer, Jochen

    2011-10-01

    Saphenous vein graft patency is frequently limited by degeneration. Experimental studies have indicated that rigid external support of venous grafts by a flexible, tubular nitinol mesh may improve graft patency. The study presented was part of a prospective, randomized, multicenter first-in-man trial investigating the safety and effectiveness of nitinol-supported venous grafts in coronary artery bypass graft (CABG) surgery. From our clinic, 25 subjects with multivessel coronary artery disease requiring saphenous vein graft CABG of the right coronary artery (RCA) and the circumflex artery were entered into the trial. Subjects were randomized to receive a mesh-supported graft on one of these arteries; the other vessel received an untreated vein graft. Graft patency was assessed by coronary angiography nine months after surgery. The implantation of mesh grafts was simple and safe. In 10 cases, a nitinol mesh-supported venous graft was anastomosed to the circumflex artery and in 15 cases to the RCA. All patients survived the observation period. A total of 72% of the patients underwent control coronary angiography. The patency rate of mesh-supported grafts was 27.8% nine months postoperatively. Conventional vein grafts showed an 85.7% patency, and arterial grafts had a 100% patency. No complications directly related to the implantation of mesh-supported grafts were observed. The promising experimental results of mesh-supported venous grafts could not be reproduced in the study presented. A critical item seems to be correct selection of nitinol mesh diameter, the anastomotic method and fixation of the mesh tube to the venous graft.

  2. Comparison of original and generic clopidogrel 600 mg loading dose in the patients who planned undergoing coronary angiography.

    PubMed

    Srimahachota, Suphot; Rojnuckarin, Ponlapat; Udayachalerm, Wasan; Buddhari, Wacin; Chaipromprasit, Jarkarpun; Lertsuwunseri, Vorarit; Akkawat, Benjaporn; Jirapattrathamrong, Somboon

    2012-12-01

    To compare the efficacy and safety of original (Plavix) and generic (Apolets) clopidogrel 600 mg loading in patients planning to undergo coronary angiography. This is an experimental design, parallel, randomized-controlled study. Coronary artery disease patients planned for cardiac catheterization were recruited Patients were randomized to receive either original or generic clopidogrel 600 mg loading dose. Platelet aggregation induced by 5 micromol/L and 20 micromol/L adenosine diphosphate (ADP) was measured by light transmission aggregometry (LTA) at baseline and 6 hours after clopidogrel 600 mg administration. Forty-nine patients were enrolled, 24 patients received original clopidogrel, and 25 patients received generic clopidogrel. After six hours of loading, there was significantly reduction in platelet aggregation induced by adenosine 5 micromol/L from 41.08 +/- 3.04% to 19.50 +/- 1.68% (p < 0.001) in original group compared to 36.76 +/- 2.66% to 21.32 +/- 2.60% (p < 0.001) in generic group. When induced by 20 micromol/L, the platelet aggregation was reduced from 58.50 +/- 2.09% to 32.25 +/- 2.30% (p < 0.001) in original group and from 61.12 +/- 2.54% to 30.04 +/- 3.14% (p < 0.001) in generic group. There was no significant difference between original and generic clopidogrel in reducing platelet aggregation induced by both adenosine 5 and 20 micromol/L. Groin hematoma was found in one case (4.2%) in the original clopidogrel group. Generic clopidogrel (Apolets) 600 mg loading dose is as effective as original clopidogrel (Plavix) in term of platelet aggregation inhibition.

  3. In Response to Laovirojjanakul W, Acharya N and Gonzales JA's "Ultra-Widefield Fluorescein Angiography in Intermediate Uveitis".

    PubMed

    Babu, Kalpana; Kumaradas, Mrinalini

    2017-12-28

    We read with great interest the article by Laovirojjanakul et al. on ultra-widefield fluorescein angiography in intermediate uveitis. We would like to share a similar case of chronic intermediate uveitis highlighting a fern-like pattern of diffuse vascular leakage on fluorescein angiography, with good visual acuity, absence of clinically active inflammation, and a similar fluorescein angiography picture over a follow-up of 4 years.

  4. Association of Medical Liability Reform With Clinician Approach to Coronary Artery Disease Management.

    PubMed

    Farmer, Steven A; Moghtaderi, Ali; Schilsky, Samantha; Magid, David; Sage, William; Allen, Nori; Masoudi, Frederick A; Dor, Avi; Black, Bernard

    2018-06-06

    Physicians often report practicing defensive medicine to reduce malpractice risk, including performing expensive but marginally beneficial tests and procedures. Although there is little evidence that malpractice reform affects overall health care spending, it may influence physician behavior for specific conditions involving clinical uncertainty. To examine whether reducing malpractice risk is associated with clinical decisions involving coronary artery disease testing and treatment. Difference-in-differences design, comparing physician-specific changes in coronary artery disease testing and treatment in 9 new-cap states that adopted damage caps between 2003 and 2005 with 20 states without caps. We used the 5% national Medicare fee-for-service random sample between 1999 and 2013. Physicians (n = 75 801; 36 647 in new-cap states) who ordered or performed 2 or more coronary angiographies. Data were analyzed from June 2015 to January 2018. Changes in ischemic evaluation rates for possible coronary artery disease, type of initial evaluation (stress testing or coronary angiography), progression from stress test to angiography, and progression from ischemic evaluation to revascularization (percutaneous coronary intervention or coronary artery bypass grafting). We studied 36 647 physicians in new-cap states and 39 154 physicians in no-cap states. New-cap states had younger populations, more minorities, lower per-capita incomes, fewer physicians per capita, and lower managed care penetration. Following cap adoption, new-cap physicians reduced invasive testing (angiography) as a first diagnostic test compared with control physicians (relative change, -24%; 95% CI, -40% to -7%; P = .005) with an offsetting increase in noninvasive stress testing (7.8%; 95% CI, -3.6% to 19.3%; P = .17), and referred fewer patients for angiography following stress testing (-21%; 95% CI, -40% to -2%; P = .03). New-cap physicians also reduced revascularization rates after ischemic evaluation (-23%; 95% CI, -40% to -4%; P = .02; driven by fewer percutaneous coronary interventions). Changes in overall ischemic evaluation rates were similar for new-cap and control physicians (-0.05%; 95% CI, -8.0% to 7.9%; P = .98). Physicians substantially altered their approach to coronary artery disease testing and follow-up after initial ischemic evaluations following adoption of damage caps. They performed a similar number of ischemic evaluations but conducted fewer initial left heart catheterizations, referred fewer stress-tested patients for left heart catheterizations, and referred fewer patients for revascularization. These findings suggest that physicians tolerate greater clinical uncertainty in coronary artery disease testing and treatment if they face lower malpractice risk.

  5. Exponentially Decelerated Contrast Media Injection Rate Combined With a Novel Patient-Specific Contrast Formula Reduces Contrast Volume Administration and Radiation Dose During Computed Tomography Pulmonary Angiography.

    PubMed

    Saade, Charbel; Mayat, Ahmad; El-Merhi, Fadi

    2016-01-01

    Matching contrast injection timing with vessel dynamics significantly improves vessel opacification and reduces contrast dose in the assessment of pulmonary embolism during computed tomography (CT) pulmonary angiography. The aim of this study was to investigate opacification of the pulmonary vasculature (PV) during CT pulmonary angiography using a patient-specific contrast formula (PSCF) and exponentially decelerated contrast media (EDCM) injection rate. Institutional review board approved this retrospective study. Computed tomography pulmonary angiography was performed on 200 patients with suspected pulmonary embolism using a 64-channel CT scanner. Patient demographics were equally distributed. Patients were randomly assigned to 2 equal protocol groups: protocol A used a PSCF, and protocol B involved the use of a PSCF combined with EDCM. The mean cross-sectional opacification profile of 8 central and 11 peripheral PVs were measured for each patient, and arteriovenous contrast ratio was calculated. Protocols were compared using Mann-Whitney U nonparametric statistics. Jackknife alternative free-response receiver operating characteristic analyses were used to assess diagnostic efficacy. Interobserver variations were investigated using kappa methods. A number of pulmonary arteries demonstrated increases in opacification (P < 0.02) for protocol B compared with A, whereas opacification in all veins was reduced in protocol B (P < 0.03). Subsequently, increased arteriovenous contrast ratio in protocol B compared with A was observed at all anatomic locations (P < 0.0002). An increase in jackknife alternative free-response receiver operating characteristic figure of merit (P < 0.0002) and interobserver variation was observed with protocol B compared with protocol A (κ = 0.3-0.73). Mean contrast volume was reduced in protocol B (29 [4] mL) compared with protocol A (33 [9] mL). Mean effective radiation dose in protocol B (1.2 [0.4] mSv) was reduced by 14% compared with protocol A (1.4 [0.6] mSv). Significant improvements in visualization of the PV can be achieved with a low contrast volume using an EDCM and PSCF. The reduced risk of cancer induction is highlighted.

  6. Outcomes after Angiography with Sodium Bicarbonate and Acetylcysteine.

    PubMed

    Weisbord, Steven D; Gallagher, Martin; Jneid, Hani; Garcia, Santiago; Cass, Alan; Thwin, Soe-Soe; Conner, Todd A; Chertow, Glenn M; Bhatt, Deepak L; Shunk, Kendrick; Parikh, Chirag R; McFalls, Edward O; Brophy, Mary; Ferguson, Ryan; Wu, Hongsheng; Androsenko, Maria; Myles, John; Kaufman, James; Palevsky, Paul M

    2018-02-15

    Intravenous sodium bicarbonate and oral acetylcysteine are widely used to prevent acute kidney injury and associated adverse outcomes after angiography without definitive evidence of their efficacy. Using a 2-by-2 factorial design, we randomly assigned 5177 patients at high risk for renal complications who were scheduled for angiography to receive intravenous 1.26% sodium bicarbonate or intravenous 0.9% sodium chloride and 5 days of oral acetylcysteine or oral placebo; of these patients, 4993 were included in the modified intention-to-treat analysis. The primary end point was a composite of death, the need for dialysis, or a persistent increase of at least 50% from baseline in the serum creatinine level at 90 days. Contrast-associated acute kidney injury was a secondary end point. The sponsor stopped the trial after a prespecified interim analysis. There was no interaction between sodium bicarbonate and acetylcysteine with respect to the primary end point (P=0.33). The primary end point occurred in 110 of 2511 patients (4.4%) in the sodium bicarbonate group as compared with 116 of 2482 (4.7%) in the sodium chloride group (odds ratio, 0.93; 95% confidence interval [CI], 0.72 to 1.22; P=0.62) and in 114 of 2495 patients (4.6%) in the acetylcysteine group as compared with 112 of 2498 (4.5%) in the placebo group (odds ratio, 1.02; 95% CI, 0.78 to 1.33; P=0.88). There were no significant between-group differences in the rates of contrast-associated acute kidney injury. Among patients at high risk for renal complications who were undergoing angiography, there was no benefit of intravenous sodium bicarbonate over intravenous sodium chloride or of oral acetylcysteine over placebo for the prevention of death, need for dialysis, or persistent decline in kidney function at 90 days or for the prevention of contrast-associated acute kidney injury. (Funded by the U.S. Department of Veterans Affairs Office of Research and Development and the National Health and Medical Research Council of Australia; PRESERVE ClinicalTrials.gov number, NCT01467466 .).

  7. Assessment of Molecular Acoustic Angiography for Combined Microvascular and Molecular Imaging in Preclinical Tumor Models

    PubMed Central

    Lindsey, Brooks D.; Shelton, Sarah E.; Foster, F. Stuart; Dayton, Paul A.

    2017-01-01

    Purpose To evaluate a new ultrasound molecular imaging approach in its ability to image a preclinical tumor model and to investigate the capacity to visualize and quantify co-registered microvascular and molecular imaging volumes. Procedures Molecular imaging using the new technique was compared with a conventional ultrasound molecular imaging technique (multi-pulse imaging) by varying the injected microbubble dose and scanning each animal using both techniques. Each of the 14 animals was randomly assigned one of three doses; bolus dose was varied, and the animals were imaged for three consecutive days so that each animal received every dose. A microvascular scan was also acquired for each animal by administering an infusion of non-targeted microbubbles. These scans were paired with co-registered molecular images (VEGFR2-targeted microbubbles), the vessels were segmented, and the spatial relationships between vessels and VEGFR2 targeting locations were analyzed. In 5 animals, an additional scan was performed in which the animal received a bolus of microbubbles targeted to E- and P-selectin. Vessel tortuosity as a function of distance from VEGF and selectin targeting was analyzed in these animals. Results Although resulting differences in image intensity due to varying microbubble dose were not significant between the two lowest doses, superharmonic imaging had significantly higher contrast-to-tissue ratio (CTR) than multi-pulse imaging (mean across all doses: 13.98 dB for molecular acoustic angiography vs. 0.53 dB for multi-pulse imaging; p = 4.9 × 10−10). Analysis of registered microvascular and molecular imaging volumes indicated that vessel tortuosity decreases with increasing distance from both VEGFR2 and selectin targeting sites. Conclusions Molecular acoustic angiography (superharmonic molecular imaging) exhibited a significant increase in CTR at all doses tested due to superior rejection of tissue artifact signals. Due to the high resolution of acoustic angiography molecular imaging, it is possible to analyze spatial relationships in aligned microvascular and molecular superharmonic imaging volumes. Future studies are required to separate the effects of biomarker expression and blood flow kinetics in comparing local tortuosity differences between different endothelial markers such as VEGFR2, E-selectin and P-selectin. PMID:27519522

  8. Aqueous Angiography–Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes

    PubMed Central

    Huang, Alex S.; Saraswathy, Sindhu; Dastiridou, Anna; Begian, Alan; Mohindroo, Chirayu; Tan, James C. H.; Francis, Brian A.; Hinton, David R.; Weinreb, Robert N.

    2016-01-01

    Purpose To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography. Methods Enucleated human eyes (14 total from 7 males and 3 females [ages 52–84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects. Results Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043). Conclusions Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent. PMID:27588614

  9. Current Perspectives in Imaging Modalities for the Assessment of Unruptured Intracranial Aneurysms: A Comparative Analysis and Review.

    PubMed

    Turan, Nefize; Heider, Robert A; Roy, Anil K; Miller, Brandon A; Mullins, Mark E; Barrow, Daniel L; Grossberg, Jonathan; Pradilla, Gustavo

    2018-05-01

    Intracranial aneurysms (IAs) are pathologic dilatations of cerebral arteries. This systematic review summarizes and compares imaging techniques for assessing unruptured IAs (UIAs). This review also addresses their uses in different scopes of practice. Pathophysiologic mechanisms are reviewed to better understand the clinical usefulness of each imaging modality. A literature review was performed using PubMed with these search terms: "intracranial aneurysm," "cerebral aneurysm," "magnetic resonance angiography (MRA)," computed tomography angiography (CTA)," "catheter angiography," "digital subtraction angiography," "molecular imaging," "ferumoxytol," and "myeloperoxidase". Only studies in English were cited. Since the development and improvement of noninvasive diagnostic imaging (computed tomography angiography and magnetic resonance angiography), many prospective studies and meta-analyses have compared these tests with gold standard digital subtraction angiography (DSA). Although computed tomography angiography and magnetic resonance angiography have lower detection rates for UIAs, they are vital in the treatment and follow-up of UIAs. The reduction in ionizing radiation and lack of endovascular instrumentation with these modalities provide benefits compared with DSA. Novel molecular imaging techniques to detect inflammation within the aneurysmal wall with the goal of stratifying risk based on level of inflammation are under investigation. DSA remains the gold standard for preoperative planning and follow-up for patients with IA. Newer imaging modalities such as ferumoxytol-enhanced magnetic resonance imaging are emerging techniques that provide critical in vivo information about the inflammatory milieu within aneurysm walls. With further study, these techniques may provide aneurysm rupture risk and prediction models for individualized patient care. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. The Carotid Revascularization Endarterectomy vs. Stenting Trial completes randomization: lessons learned and anticipated results.

    PubMed

    Lal, Brajesh K; Brott, Thomas G

    2009-11-01

    The Carotid Revascularization Endarterectomy vs. Stenting Trial (CREST) completed randomization on July 18, 2008. Sponsored by the National Institute of Neurological Disorders and Stroke (NINDS), the trial has enrolled 2,522 participants across North America and is the largest randomized clinical trial (RCT) comparing the efficacy of carotid artery stenting (CAS) to carotid endarterectomy (CEA). It is also the largest RCT to assess carotid revascularization in both symptomatic and asymptomatic patients with carotid artery stenosis. Conventional-risk patients with symptomatic carotid stenosis (> or =50% by angiography, > or =70% by ultrasound) or asymptomatic carotid stenosis (> or =60% by angiography, > or =70% by ultrasound) were randomized to both treatment arms in a 1:1 ratio. Eligibility criteria for CREST were similar to those of the previous NINDS-sponsored CEA RCTs. The investigational devices used in the CAS arm of the study are the RX Acculink stent and the RX Accunet embolic protection system, (Abbott Vascular, Santa Clara, Calif). The primary aim is to contrast the efficacy of CAS versus CEA in preventing stroke, myocardial infarction, and all-cause mortality during a 30-day peri-procedural period, and ipsilateral stroke over the follow-up period (extending up to four years). The secondary aims are to contrast the efficacy of CAS and CEA in men and women, the restenosis rates of the two procedures, health-related quality of life, and cost effectiveness of CAS and CEA. The conclusion of enrollment in CREST marks the end of a long recruitment period from 117 community and academic hospital centers across the United States and Canada. Each surgeon and interventionalist underwent a rigorous credentialing process that included performance-assessment of prior CEA and CAS procedures. Credentialing of interventionalists also included a review of additional CAS procedures enrolled into a CREST lead-in phase prior to entering patients into the randomized trial; 1564 patients were enrolled in the lead-in, the final pathway for the largest credentialing effort to date for any clinical trial. CREST will provide long-term follow-up after carotid revascularization based on systematic ultrasonographic and neurologic surveillance, and on quality of life and cost-effectiveness comparisons between CAS and CEA in the setting of a RCT. We present a brief description of the CREST protocol, impediments that were overcome during the trial, salient results from the lead-in phase of the trial, a summary of enrollment activities and characteristics of the final cohort, and a timeline for anticipated results from the randomized phase.

  11. Coronary CT Angiography-derived Fractional Flow Reserve: Machine Learning Algorithm versus Computational Fluid Dynamics Modeling.

    PubMed

    Tesche, Christian; De Cecco, Carlo N; Baumann, Stefan; Renker, Matthias; McLaurin, Tindal W; Duguay, Taylor M; Bayer, Richard R; Steinberg, Daniel H; Grant, Katharine L; Canstein, Christian; Schwemmer, Chris; Schoebinger, Max; Itu, Lucian M; Rapaka, Saikiran; Sharma, Puneet; Schoepf, U Joseph

    2018-04-10

    Purpose To compare two technical approaches for determination of coronary computed tomography (CT) angiography-derived fractional flow reserve (FFR)-FFR derived from coronary CT angiography based on computational fluid dynamics (hereafter, FFR CFD ) and FFR derived from coronary CT angiography based on machine learning algorithm (hereafter, FFR ML )-against coronary CT angiography and quantitative coronary angiography (QCA). Materials and Methods A total of 85 patients (mean age, 62 years ± 11 [standard deviation]; 62% men) who had undergone coronary CT angiography followed by invasive FFR were included in this single-center retrospective study. FFR values were derived on-site from coronary CT angiography data sets by using both FFR CFD and FFR ML . The performance of both techniques for detecting lesion-specific ischemia was compared against visual stenosis grading at coronary CT angiography, QCA, and invasive FFR as the reference standard. Results On a per-lesion and per-patient level, FFR ML showed a sensitivity of 79% and 90% and a specificity of 94% and 95%, respectively, for detecting lesion-specific ischemia. Meanwhile, FFR CFD resulted in a sensitivity of 79% and 89% and a specificity of 93% and 93%, respectively, on a per-lesion and per-patient basis (P = .86 and P = .92). On a per-lesion level, the area under the receiver operating characteristics curve (AUC) of 0.89 for FFR ML and 0.89 for FFR CFD showed significantly higher discriminatory power for detecting lesion-specific ischemia compared with that of coronary CT angiography (AUC, 0.61) and QCA (AUC, 0.69) (all P < .0001). Also, on a per-patient level, FFR ML (AUC, 0.91) and FFR CFD (AUC, 0.91) performed significantly better than did coronary CT angiography (AUC, 0.65) and QCA (AUC, 0.68) (all P < .0001). Processing time for FFR ML was significantly shorter compared with that of FFR CFD (40.5 minutes ± 6.3 vs 43.4 minutes ± 7.1; P = .042). Conclusion The FFR ML algorithm performs equally in detecting lesion-specific ischemia when compared with the FFR CFD approach. Both methods outperform accuracy of coronary CT angiography and QCA in the detection of flow-limiting stenosis. © RSNA, 2018.

  12. Infrared-laser-based fundus angiography

    NASA Astrophysics Data System (ADS)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  13. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin

    2007-09-15

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels.

  14. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasationmore » of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.« less

  15. Intravenous volume tomographic pulmonary angiography imaging

    NASA Astrophysics Data System (ADS)

    Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng

    1999-05-01

    This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is superior to spiral CT for cross sectional pulmonary angiography.

  16. Coronary angiography in worsening heart failure: determinants, findings and prognostic implications.

    PubMed

    Ferreira, João Pedro; Rossignol, Patrick; Demissei, Biniyam; Sharma, Abhinav; Girerd, Nicolas; Anker, Stefan D; Cleland, John G; Dickstein, Kenneth; Filippatos, Gerasimos; Hillege, Hans L; Lang, Chim C; Metra, Marco; Ng, Leong L; Ponikowski, Piotr; Samani, Nilesh J; van Veldhuisen, Dirk J; Zwinderman, Aeilko H; Voors, Adriaan; Zannad, Faiez

    2018-04-01

    Coronary angiography is regularly performed in patients with worsening signs and/or symptoms of heart failure (HF). However, little is known on the determinants, findings and associated clinical outcomes of coronary angiography performed in patients with worsening HF. The BIOSTAT-CHF (a systems BIOlogy Study to TAilored Treatment in Chronic Heart Failure) programme enrolled 2516 patients with worsening symptoms and/or signs of HF, either hospitalised or in the outpatient setting. All patients were included in the present analysis. Of the 2516 patients included, 315 (12.5%) underwent coronary angiography within the 30 days after the onset of worsening symptoms and/or signs of HF. Subjects who underwent angiography were more often observed as inpatients, had more often an overt acute coronary syndrome, had higher troponin I levels, were younger and had better renal function (all p≤0.01). Patients who underwent coronary angiography had a lower risk of the primary outcome of death and/or HF hospitalisation (adjusted HR=0.71, 95% CI 0.57 to 0.89, p=0.003) and death (adjusted HR=0.59, 95% CI 0.43 to 0.80, p=0.001). Among the patients who underwent coronary angiography, those with a coronary stenosis (39%) had a worse prognosis than those without stenosis (adjusted HR for the primary outcome=1.71, 95% CI 1.10 to 2.64, p=0.016). Coronary angiography was performed in <13% of patients with symptoms and/or signs of worsening HF. These patients were remarkably different from those who did not undergo coronary angiography and had a lower risk of subsequent events. The presence of coronary stenosis on coronary angiography was associated with a worse prognosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Methods and algorithms for optical coherence tomography-based angiography: a review and comparison

    NASA Astrophysics Data System (ADS)

    Zhang, Anqi; Zhang, Qinqin; Chen, Chieh-Li; Wang, Ruikang K.

    2015-10-01

    Optical coherence tomography (OCT)-based angiography is increasingly becoming a clinically useful and important imaging technique due to its ability to provide volumetric microvascular networks innervating tissue beds in vivo without a need for exogenous contrast agent. Numerous OCT angiography algorithms have recently been proposed for the purpose of contrasting microvascular networks. A general literature review is provided on the recent progress of OCT angiography methods and algorithms. The basic physics and mathematics behind each method together with its contrast mechanism are described. Potential directions for future technical development of OCT based angiography is then briefly discussed. Finally, by the use of clinical data captured from normal and pathological subjects, the imaging performance of vascular networks delivered by the most recently reported algorithms is evaluated and compared, including optical microangiography, speckle variance, phase variance, split-spectrum amplitude decorrelation angiography, and correlation mapping. It is found that the method that utilizes complex OCT signal to contrast retinal blood flow delivers the best performance among all the algorithms in terms of image contrast and vessel connectivity. The purpose of this review is to help readers understand and select appropriate OCT angiography algorithm for use in specific applications.

  18. Dark and white lesions observed in central serous chorioretinopathy on optical coherence tomography angiography.

    PubMed

    De Bats, Flore; Cornut, Pierre-Loïc; Wolff, Benjamin; Kodjikian, Laurent; Mauget-Faÿsse, Martine

    2018-03-01

    To describe abnormal dark (hyposignal) and white (hypersignal) lesions observed on optical coherence tomography angiography in central serous chorioretinopathy. Prospective, multicenter, and descriptive study including patients with active or quiescent central serous chorioretinopathy. All patients had undergone a complete ophthalmic examination. Abnormal dark lesions were detected as "dark spots" and "dark areas" on optical coherence tomography angiography. A "dark spot" could correspond to six different abnormalities: pigment epithelium detachment, subretinal deposit, "Lucency" within surrounding subretinal fibrin, choroidal cavitation, choroidal excavation, and choroidal fluid. A "dark area" could be related to a serous retinal detachment or choriocapillary compression. Abnormal white lesions were also detected: A "white spot" could correspond with the leaking point on fluorescein angiography or with hyper-reflective dots; A "white filamentous pattern" at the Brüch's membrane level corresponded to abnormal choroidal neovascular vessels. A semiology is described using optical coherence tomography angiography in central serous chorioretinopathy as abnormal dark and white lesions. Multimodal imaging is mandatory in addition to optical coherence tomography angiography to diagnose non-neovascular retinal and choroidal central serous chorioretinopathy lesions. However, optical coherence tomography angiography alone is helpful in detecting choroidal neovascular membrane in central serous chorioretinopathy.

  19. Predictors of drusen reduction after subthreshold infrared (810 nm) diode laser macular grid photocoagulation for nonexudative age-related macular degeneration.

    PubMed

    Rodanant, Nuttawut; Friberg, Thomas R; Cheng, Lingyun; Aurora, Ajay; Bartsch, Dirk; Toyoguchi, Mitsuko; Corbin, Patricia S; El-Bradey, Mohamed H; Freeman, William R

    2002-10-01

    To determine the predictors of drusen reduction in eyes with nonexudative age-related macular degeneration (ARMD) treated with subthreshold infrared (810 nm) diode laser macular grid photocoagulation. Additionally, to determine the relationship of laser-induced drusen reduction and best-corrected visual acuity (BCVA) 18 months after laser treatment. Randomized controlled clinical trial. Fifty patients (100 eyes) with bilateral nonexudative ARMD were enrolled at two centers. One eye of each patient was randomized to the observation; the other eye was treated with 48 subthreshold (invisible end point) applications of infrared (810 nm) diode laser in a macular grid pattern. The eyes that received subthreshold laser treatment were compared with the eyes that received no treatment. The baseline fundus characteristics (number, size, and distribution of drusen, as well as focal hyperpigmentation) from two macula areas (central 1500 micro diameter, pericentral 1500 micro ring area) on stereo color photographs, the number of laser-induced lesions, and the area of laser induced retinal pigment epithelial (RPE) lesions on fluorescein angiography 3 months after treatment were studied as predictors of major drusen reduction (> or = 50% drusen reduction from baseline) 18 months after laser treatment. BCVA at baseline and 18 months later was compared in observation eyes and in laser-treated eyes. Eighteen months after randomization, 24 (48%) of 50 eyes treated with subthreshold laser had major drusen reduction compared with three (6%) of 50 observation eyes (P =.00001). At 3 months post-treatment in laser-treated eyes with major drusen reduction, the mean number of laser-induced lesions on fluorescein angiography was 30.7 and the mean area of RPE change was 0.81 mm(2) compared with 14.8 laser-induced lesions and 0.35 mm(2) area of RPE change in eyes without major drusen reduction (P =.0001 and P =.0003, respectively). At baseline, fundus characteristics were not significantly different between observation eyes and laser-treated eyes or between the major drusen reduction group and the nonmajor drusen reduction group. At 18 months after treatment, BCVA was not significantly different in laser-treated eyes and in observation eyes. Subthreshold infrared (810 nm) diode laser macular grid photocoagulation in eyes with nonexudative ARMD significantly reduced drusen 18 months after laser treatment. Both the number of subthreshold laser lesions and the area of RPE changes visible on fluorescein angiography 3 months after treatment appeared to be predictors for major drusen reduction 18 months after treatment. However, it remains to be determined whether laser-induced drusen reduction is beneficial for visual acuity or reduces the incidence of choroidal neovascularization (CNV) in eyes with nonexudative ARMD.

  20. Effect of screening for coronary artery disease using CT angiography on mortality and cardiac events in high-risk patients with diabetes: the FACTOR-64 randomized clinical trial.

    PubMed

    Muhlestein, Joseph B; Lappé, Donald L; Lima, Joao A C; Rosen, Boaz D; May, Heidi T; Knight, Stacey; Bluemke, David A; Towner, Steven R; Le, Viet; Bair, Tami L; Vavere, Andrea L; Anderson, Jeffrey L

    2014-12-03

    Coronary artery disease (CAD) is a major cause of cardiovascular morbidity and mortality in patients with diabetes mellitus, yet CAD often is asymptomatic prior to myocardial infarction (MI) and coronary death. To assess whether routine screening for CAD by coronary computed tomography angiography (CCTA) in patients with type 1 or type 2 diabetes deemed to be at high cardiac risk followed by CCTA-directed therapy would reduce the risk of death and nonfatal coronary outcomes. The FACTOR-64 study was a randomized clinical trial in which 900 patients with type 1 or type 2 diabetes of at least 3 to 5 years' duration and without symptoms of CAD were recruited from 45 clinics and practices of a single health system (Intermountain Healthcare, Utah), enrolled at a single-site coordinating center, and randomly assigned to CAD screening with CCTA (n = 452) or to standard national guidelines-based optimal diabetes care (n = 448) (targets: glycated hemoglobin level <7.0%, low-density lipoprotein cholesterol level <100 mg/dL, systolic blood pressure <130 mm Hg). All CCTA imaging was performed at the coordinating center. Standard therapy or aggressive therapy (targets: glycated hemoglobin level <6.0%, low-density lipoprotein cholesterol level <70 mg/dL, high-density lipoprotein cholesterol level >50 mg/dL [women] or >40 mg/dL [men], triglycerides level <150 mg/dL, systolic blood pressure <120 mm Hg), or aggressive therapy with invasive coronary angiography, was recommended based on CCTA findings. Enrollment occurred between July 2007 and May 2013, and follow-up extended to August 2014. The primary outcome was a composite of all-cause mortality, nonfatal MI, or unstable angina requiring hospitalization; the secondary outcome was ischemic major adverse cardiovascular events (composite of CAD death, nonfatal MI, or unstable angina). At a mean follow-up time of 4.0 (SD, 1.7) years, the primary outcome event rates were not significantly different between the CCTA and the control groups (6.2% [28 events] vs 7.6% [34 events]; hazard ratio, 0.80 [95% CI, 0.49-1.32]; P = .38). The incidence of the composite secondary end point of ischemic major adverse cardiovascular events also did not differ between groups (4.4% [20 events] vs 3.8% [17 events]; hazard ratio, 1.15 [95% CI, 0.60-2.19]; P = .68). Among asymptomatic patients with type 1 or type 2 diabetes, use of CCTA to screen for CAD did not reduce the composite rate of all-cause mortality, nonfatal MI, or unstable angina requiring hospitalization at 4 years. These findings do not support CCTA screening in this population. clinicaltrials.gov Identifier: NCT00488033.

  1. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography.

    PubMed

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  2. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography

    PubMed Central

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    Background The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Objectives Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Methods Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Results Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Conclusions Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. PMID:25634390

  3. Prevention of Contrast-Induced AKI: A Review of Published Trials and the Design of the Prevention of Serious Adverse Events following Angiography (PRESERVE) Trial

    PubMed Central

    Gallagher, Martin; Kaufman, James; Cass, Alan; Parikh, Chirag R.; Chertow, Glenn M.; Shunk, Kendrick A.; McCullough, Peter A.; Fine, Michael J.; Mor, Maria K.; Lew, Robert A.; Huang, Grant D.; Conner, Todd A.; Brophy, Mary T.; Lee, Joanne; Soliva, Susan; Palevsky, Paul M.

    2013-01-01

    Summary Contrast-induced AKI (CI-AKI) is a common condition associated with serious, adverse outcomes. CI-AKI may be preventable because its risk factors are well characterized and the timing of renal insult is commonly known in advance. Intravenous (IV) fluids and N-acetylcysteine (NAC) are two of the most widely studied preventive measures for CI-AKI. Despite a multitude of clinical trials and meta-analyses, the most effective type of IV fluid (sodium bicarbonate versus sodium chloride) and the benefit of NAC remain unclear. Careful review of published trials of these interventions reveals design limitations that contributed to their inconclusive findings. Such design limitations include the enrollment of small numbers of patients, increasing the risk for type I and type II statistical errors; the use of surrogate primary endpoints defined by small increments in serum creatinine, which are associated with, but not necessarily causally related to serious, adverse, patient-centered outcomes; and the inclusion of low-risk patients with intact baseline kidney function, yielding low event rates and reduced generalizability to a higher-risk population. The Prevention of Serious Adverse Events following Angiography (PRESERVE) trial is a randomized, double-blind, multicenter trial that will enroll 8680 high-risk patients undergoing coronary or noncoronary angiography to compare the effectiveness of IV isotonic sodium bicarbonate versus IV isotonic sodium chloride and oral NAC versus oral placebo for the prevention of serious, adverse outcomes associated with CI-AKI. This article discusses key methodological issues of past trials investigating IV fluids and NAC and how they informed the design of the PRESERVE trial. PMID:23660180

  4. Current Understanding of Dolichoarteriopathies of the Internal Carotid Artery: A Review

    PubMed Central

    Yu, Jinlu; Qu, Lai; Xu, Baofeng; Wang, Shouchun; Li, Chao; Xu, Xan; Yang, Yi

    2017-01-01

    Dolichoarteriopathies of the internal carotid artery (DICAs) are not uncommon, and although several studies have investigated DICAs, several questions regarding the etiology and best management course for DICAs remain unanswered. It is also difficult to correlate the occurrence of DICAs with the onset of clinical symptoms. Therefore, we surveyed the literature in PubMed and performed a review of DICAs to offer a comprehensive picture of our understanding of DICAs. We found that DICAs can be classified into three types, specifically tortuous, coiling and kinking, and are not associated with atherosclerotic risk factors. Cerebral hemodynamic changes are mainly associated with the degree of bending of DICAs. DICAs can result in symptoms of the brain and eyes due to insufficient blood supply and can co-occur with a pulsatile cervical mass, a pharyngeal bulge and pulsation. The diagnostic tools for the assessment of DICAs include Doppler ultrasonography, computed tomography angiography (CTA), magnetic resonance angiography (MRA) and digital subtraction angiography (DSA), and although DSA remains the gold standard, Doppler ultrasonography is a convenient method that provides useful data for the morphological evaluation of DICAs. CTA and MRA are efficient methods for detecting the morphology of the cervical segment of DICAs. Some DICAs should be treated surgically based on certain indications, and several methods, including correcting the bending or shortening of DICAs, have been developed for the treatment of DICAs. The appropriate treatment of DICAs results in good outcomes and is associated with low morbidity and mortality rates. However, despite the success of surgical reconstruction, an appropriate therapeutic treatment remains a subject of numerous debates due to the lack of multicentric, randomized, prospective studies. PMID:28824313

  5. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    PubMed

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  6. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    PubMed

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  7. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial

    PubMed Central

    Rief, Matthias; Martus, Peter; Kendziora, Benjamin; Feger, Sarah; Dreger, Henryk; Priem, Sascha; Knebel, Fabian; Böhm, Marko; Schlattmann, Peter; Hamm, Bernd; Schönenberger, Eva; Laule, Michael; Zimmermann, Elke

    2016-01-01

    Objective To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease. Design Prospective randomised single centre trial. Setting University hospital in Germany. Participants 340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain. Interventions 168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes. Main outcome measure The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography. Results Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard ratio 0.90, 95% confidence interval 0.30 to 2.69, P=0.86). 79% of patients stated that they would prefer CT for subsequent testing. The study was conducted at a University hospital in Germany and thus the performance of CT may be different in routine clinical practice. The prevalence was lower than expected, resulting in an underpowered study for the predefined primary outcome. Conclusions CT increased the diagnostic yield and was a safe gatekeeper for coronary angiography with no increase in long term events. The length of stay was shortened by 22.9 hours with CT, and patients preferred non-invasive testing. Trial registration ClinicalTrials.gov NCT00844220. PMID:27777234

  8. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial.

    PubMed

    Dewey, Marc; Rief, Matthias; Martus, Peter; Kendziora, Benjamin; Feger, Sarah; Dreger, Henryk; Priem, Sascha; Knebel, Fabian; Böhm, Marko; Schlattmann, Peter; Hamm, Bernd; Schönenberger, Eva; Laule, Michael; Zimmermann, Elke

    2016-10-24

     To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease.  Prospective randomised single centre trial.  University hospital in Germany.  340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain.  168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes.  The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography.  Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard ratio 0.90, 95% confidence interval 0.30 to 2.69, P=0.86). 79% of patients stated that they would prefer CT for subsequent testing. The study was conducted at a University hospital in Germany and thus the performance of CT may be different in routine clinical practice. The prevalence was lower than expected, resulting in an underpowered study for the predefined primary outcome.  CT increased the diagnostic yield and was a safe gatekeeper for coronary angiography with no increase in long term events. The length of stay was shortened by 22.9 hours with CT, and patients preferred non-invasive testing.Trial registration ClinicalTrials.gov NCT00844220. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Evaluation of a High Concentrated Contrast Media Injection Protocol in Combination with Low Tube Current for Dose Reduction in Coronary Computed Tomography Angiography: A Randomized, Two-center Prospective Study.

    PubMed

    Sun, Yibo; Hua, Yanqing; Wang, Mingpeng; Mao, Dingbiao; Jin, Xiu; Li, Cheng; Shi, Kailei; Xu, Jianrong

    2017-12-01

    The study aimed to prospectively evaluate the radiation dose reduction potential and image quality (IQ) of a high-concentration contrast media (HCCM) injection protocol in combination with a low tube current (mAs) in coronary computed tomography angiography. Eighty-one consecutive patients (mean age: 62 years; 34 females; body mass index: 18-31) were included and randomized-assigned into two groups. All computed tomography (CT) examinations were performed in two groups with the same tube voltage (100 kV), flow rate of contrast medium (5.0 mL/s), and iodine dose (22.8 g). An automatic mAs and low concentration contrast medium (300 mgI/mL) were used in group A, whereas effective mAs was reduced by a factor 0.6 along with HCCM (400 mgI/mL) in group B. Radiation dose was assessed (CT dose index [CTDI vol ] and dose length product), and vessel-based objective IQ for various regions of interest (enhancement, noise, signal-to-noise ratio, and contrast-to-noise ratio), subjective IQ, noise, and motion artifacts were analyzed overall and vessel-based with a 5-point Likert scale. The CT attenuation of coronary arteries and image noise in group B were significantly higher than those in group A (ranges: 507.5-548.1 Hounsfield units vs 407.5-444.5 Hounsfield units; and 20.3 ± 8.6 vs 17.7 ± 8.0) (P ≤ 0.0166). There was no significant difference between the two groups in signal-to-noise ratio, contrast-to-noise ratio, and subjective IQ of coronary arteries (29.4-31.7, 30.0-37.0, and medium score of 5 in group A vs 29.4-32.4, 27.7-36.3, and medium score of 5 in group B, respectively, P ≥ 0.1859). Both mean CTDI vol and dose length product in group B were 58% of those of group A. HCCM combined with low tube current allows dose reduction in coronary computed tomography angiography and does not compromise IQ. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. The utility of postmortem computed tomography selective coronary angiography in parallel with autopsy.

    PubMed

    Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro

    2013-12-01

    Historically, coronary angiography of the isolated heart has played an important role in the detection of stenotic or occlusive lesions that are difficult to identify by autopsy alone. Meanwhile, although the application of multidetector computed tomography (MDCT) to forensic fields has accelerated recently, isolated single organ angiography with MDCT is rarely performed. In this article, we present an evaluation of postmortem selective coronary CT angiography of the isolated heart with MDCT and discuss its utility for autopsy. First, in a preliminary experiment using pig coronary artery, we examined the behavior of water soluble contrast material on postmortem computed tomography angiography (PMCTA) and found that better angiographic images were acquired when the viscosity of the contrast material was increased and CT was performed under conditions of sustained perfusion. Based on these results, we devised a selective coronary angiography procedure using a pressurized bag for drip infusion that can be performed easily, quickly, and at low cost. The angiographic images obtained provided useful supportive evidence of autopsy findings suggestive of ischemic heart disease. With active discussions underway in forensic fields on the proper use of postmortem computed tomography, PMCTA has also naturally attracted attention as it compensates for some of the shortcomings of CT alone. Although PMCTA typically involves whole-body angiography, if we view PMCTA as one of the many useful and supplementary tools available for autopsy, then isolated heart angiography continues to have utility in autopsy today.

  11. The use of carbon dioxide angiography for renal sympathetic denervation: a technical report.

    PubMed

    Renton, Mary; Hameed, Mohammad A; Dasgupta, Indranil; Hoey, Edward T D; Freedman, Jonathan; Ganeshan, Arul

    2016-12-01

    Hypertension is the leading attributable cause of cardiovascular mortality worldwide. Patients with hypertension have multiple comorbidities including high rates of concomitant renal disease. Current pharmacological approaches are inadequate in the treatment of resistant hypertension. Renal sympathetic denervation (RDN) has been shown to effectively treat resistant hypertension. The traditional use of iodinated contrast in RDN is contraindicated in patients with significant renal insufficiency. In patients with renal impairment, carbon dioxide (CO 2 ) can be used as an alternative contrast material for RDN. This article describes the technical aspects of RDN using CO 2 angiography. Our centre is experienced in the innovative RDN procedure using CO 2 angiography. We describe the protocol for CO 2 angiography for RDN using a home-made CO 2 delivery system and the Symplicity ™ (Minneapolis MN 55432 USA) catheter (Medtronic) device. CO 2 angiography is an excellent alternative to iodinated contrast for RDN procedures. CO 2 angiography for RDN is a safe and effective alternative to iodinated contrast. RDN using CO 2 angiography is an easy and feasible procedure that can be used in patients with renal insufficiency or iodinated contrast allergies. Advances in knowledge: There is a paucity of descriptive reports for CO 2 angiography for RDN and we provide details of the optimal protocol for the procedure. In particular, we describe the use of a Symplicity Spyral ™ catheter (Medtronic), which has not been reported to date for use in this procedure.

  12. Naringin improves random skin flap survival in rats.

    PubMed

    Cheng, Liang; Chen, Tingxiang; Tu, Qiming; Li, Hang; Feng, Zhenghua; Li, Zhijie; Lin, Dingsheng

    2017-11-07

    Random-pattern flap transfer is commonly used to treat soft-tissue defects. However, flap necrosis remains a serious problem. Naringin accelerates angiogenesis by activating the expression of vascular endothelial growth factor (VEGF). In the present study, we investigated whether naringin improves the survival of random skin flaps. Compared with controls, the naringin-treated groups exhibited significantly larger mean areas of flap survival, significantly increased SOD activity and VEGF expression, and significantly reduced MDA level. Hematoxylin and eosin (HE) staining revealed that naringin promoted angiogenesis and inhibited inflammation. "McFarlane flap" models were established in 90 male Sprague-Dawley (SD) rats divided into three groups: a 40 mg/kg control group (0.5 % sodium carboxymethylcellulose), a 40 mg/kg naringin-treated group, and an 80 mg/kg naringin-treated group. The extent of necrosis was measured 7 days later, and tissue samples were subjected to histological analysis. Angiogenesis was evaluated via lead oxide-gelatin angiography, immunohistochemistry, and laser Doppler imaging. Inflammation was evaluated by measurement of serum TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) levels. Oxidative stress was assessed by measuring superoxide dismutase (SOD) activity and the malondialdehyde (MDA) level. Naringin improved random skin flap survival.

  13. Magnetic resonance angiography of the pediatric abdomen and pelvis: techniques and imaging findings.

    PubMed

    Sada, David M; Vellody, Ranjith; Liu, Peter S

    2013-11-01

    Although traditional catheter-based angiography has been the gold standard for pediatric abdominal and pelvic vascular imaging for the past several decades, advances in magnetic resonance angiography (MRA) have made it a viable alternative. MRA offers several advantages in that it is noninvasive, can be performed without ionizing radiation, and does not necessarily rely on contrast administration. The ability of modern MRA techniques to define variant vascular anatomy and detect vascular disease may obviate traditional angiography in some patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results.

    PubMed

    Conforto, Adriana Bastos; Fregni, Felipe; Puglia, Paulo; Leite, Claudia da Costa; Yamamoto, Fabio Iuji; Coracini, Karen F; Scaff, Milberto

    2006-06-01

    We preliminarily investigated the relevance of performing digital subtraction angiography (DSA) in addition to magnetic resonance angiography (MRA) in definition of ischemic stroke etiology in young patients. DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.

  15. OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY SHOWS INNER CHOROIDAL ISCHEMIA IN ACUTE POSTERIOR MULTIFOCAL PLACOID PIGMENT EPITHELIOPATHY.

    PubMed

    Dolz-Marco, Rosa; Sarraf, David; Giovinazzo, Vincent; Freund, K Bailey

    2017-01-01

    To describe multimodal imaging findings of an evolving case of acute posterior multifocal placoid pigment epitheliopathy occurring in a young healthy male. Case report of a patient with acute posterior multifocal placoid pigment epitheliopathy including comprehensive systemic and ocular examinations. Ultra-widefield autofluorescence, fluorescein angiography, indocyanine green angiography, and serial optical coherence tomography angiography were performed. A 34-year-old male presented with acute vision loss in his left eye for 2 weeks. His best-corrected visual acuity was 20/20 in his right eye and 20/200 in his left eye. Dilated funduscopic examination revealed multiple creamy white deep retinal lesions showing macular involvement of the left eye with a diffuse area of pigmentary changes. The presence of multiple areas of hypoperfusion of the inner choroid were demonstrated with fluorescein and indocyanine green angiography. Serial optical coherence tomography angiography showed multiple evolving areas of decreased flow at the level of the inner choroid. Although the pathogenesis of acute posterior multifocal placoid pigment epitheliopathy remains unknown, there is growing evidence of a primary choroidal involvement with secondary damage to the overlying retinal pigment epithelium and the outer retinal layers. Optical coherence tomography angiography may provide valuable information for the diagnosis and follow-up of this condition avoiding invasive angiographic procedures.

  16. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    PubMed Central

    Ito, Hiromichi; Matsushita, Shonosuke; Hyodo, Kazuyuki; Sato, Yukio; Sakakibara, Yuzuru

    2013-01-01

    Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity. PMID:23412496

  17. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Özgen, Ali, E-mail: draliozgen@hotmail.com; Sanioğlu, Soner; Bingöl, Uğur Anıl

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatininemore » levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.« less

  18. DETECTION OF NONEXUDATIVE CHOROIDAL NEOVASCULARIZATION IN AGE-RELATED MACULAR DEGENERATION WITH OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Palejwala, Neal V; Jia, Yali; Gao, Simon S; Liu, Liang; Flaxel, Christina J; Hwang, Thomas S; Lauer, Andreas K; Wilson, David J; Huang, David; Bailey, Steven T

    2015-11-01

    To evaluate eyes with age-related macular degeneration and high-risk characteristics for choroidal neovascularization (CNV) with optical coherence tomographic (OCT) angiography to determine whether earlier detection of CNV is possible. Eyes with drusen, pigmentary changes, and with CNV in the fellow eye were scanned with a 70-kHz spectral domain OCT system (Optovue RTVue-XR Avanti). The split-spectrum amplitude-decorrelation angiography (SSADA) algorithm was used to distinguish blood flow from static tissue. Two masked graders reviewed scans for CNV, defined as flow in the outer retinal/sub-RPE slab. Choroidal neovascularization flow area repeatability and between-grader reproducibility were calculated. Of 32 eyes, 2 (6%) were found to have Type 1 CNV with OCT angiography. The lesions were not associated with leakage on fluorescein angiography or fluid on OCT. One case was followed for 8 months without treatment, and the CNV flow area enlarged slightly without fluid buildup on OCT or vision loss. Between-grader reproducibility of the CNV flow area was 9.4% (coefficient of variation) and within-visit repeatability was 5.2% (pooled coefficient of variation). Optical coherence tomographic angiography can detect the presence of nonexudative CNV, lesions difficult to identify with fluorescein angiography and OCT. Further study is needed to understand the significance and natural history of these lesions.

  19. Optical coherence tomography angiography in age-related macular degeneration: The game changer.

    PubMed

    Lupidi, Marco; Cerquaglia, Alessio; Chhablani, Jay; Fiore, Tito; Singh, Sumit Randhir; Cardillo Piccolino, Felice; Corbucci, Roberta; Coscas, Florence; Coscas, Gabriel; Cagini, Carlo

    2018-04-01

    Optical coherence tomography angiography is one of the biggest advances in ophthalmic imaging. It enables a depth-resolved assessment of the retinal and choroidal blood flow, far exceeding the levels of detail commonly obtained with dye angiographies. One of the first applications of optical coherence tomography angiography was in detecting the presence of choroidal neovascularization in age-related macular degeneration and establishing its position in relation to the retinal pigmented epithelium and Bruch's membrane, and thereby classifying the CNV as type 1, type 2, type 3, or mixed lesions. Optical coherence tomography angiograms, due to the longer wavelength used by optical coherence tomography, showed a more distinct choroidal neovascularization vascular pattern than fluorescein angiography, since there is less suffering from light scattering or is less obscured by overlying subretinal hemorrhages or exudation. Qualitative and quantitative assessments of optical coherence tomography angiography findings in exudative and nonexudative age-related macular degeneration have been largely investigated within the past 3 years both in clinical and experimental settings. This review constitutes an up-to-date of all the potential applications of optical coherence tomography angiography in age-related macular degeneration in order to better understand how to translate its theoretical usefulness into the current clinical practice.

  20. Systematic preoperative coronary angiography and stenting improves postoperative results of carotid endarterectomy in patients with asymptomatic coronary artery disease: a randomised controlled trial.

    PubMed

    Illuminati, G; Ricco, J-B; Greco, C; Mangieri, E; Calio', F; Ceccanei, G; Pacilè, M A; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Mazzesi, G; Miraldi, F; Tritapepe, L

    2010-02-01

    To evaluate the usefulness of systematic coronary angiography followed, if needed, by coronary artery angioplasty (percutaneous coronary intervention (PCI)) on the incidence of cardiac ischaemic events after carotid endarterectomy (CEA) in patients without evidence of coronary artery disease (CAD). From January 2005 to December 2008, 426 patients, candidates for CEA, with no history of CAD and with normal cardiac ultrasound and electrocardiography (ECG), were randomised into two groups. In group A (n=216) all the patients had coronary angiography performed before CEA. In group B, all the patients had CEA without previous coronary angiography. In group A, 66 patients presenting significant coronary artery lesions at angiography received PCI before CEA. They subsequently underwent surgery under aspirin (100 mg day(-1)) and clopidogrel (75 mg day(-1)). CEA was performed within a median delay of 4 days after PCI (range: 1-8 days). Risk factors, indications for CEA and surgical techniques were comparable in both groups (p>0.05). The primary combined endpoint of the study was the incidence of postoperative myocardial ischaemic events combined with the incidence of complications of coronary angiography. Secondary endpoints were death and stroke rates after CEA and incidence of cervical haematoma. Postoperative mortality was 0% in group A and 0.9% in group B (p=0.24). One postoperative stroke (0.5%) occurred in group A, and two (0.9%) in group B (p=0.62). No postoperative myocardial event was observed in group A, whereas nine ischaemic events were observed in group B, including one fatal myocardial infarction (p=0.01). Binary logistic regression analysis demonstrated that preoperative coronary angiography was the only independent variable that predicted the occurrence of postoperative coronary ischaemia after CEA. The odds ratio for coronary angiography (group A) indicated that when holding all other variables constant, a patient having preoperative coronary angiography before carotid surgery was 4 times less likely to have a cardiac ischaemic event after carotid surgery. No complications related to coronary angiography were observed and no cervical haematomas occurred in patients undergoing surgery under aspirin and clopidogrel in this study. Systematic preoperative coronary angiography, possibly followed by PCI, significantly reduces the incidence of postoperative myocardial events after CEA in patients without clinical evidence of CAD. Copyright (c) 2009 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Magnetic resonance angiography in the follow-up of distal lower-extremity bypass surgery: comparison with duplex ultrasound and digital subtraction angiography.

    PubMed

    Meissner, Oliver A; Verrel, Frauke; Tató, Federico; Siebert, Uwe; Ramirez, Heldin; Ruppert, Volker; Schoenberg, Stefan O; Reiser, Maximilian

    2004-11-01

    The danger of limb loss as a consequence of acute occlusion of infrapopliteal bypasses underscores the requirement for careful patient follow-up. The objective of this study was to determine the agreement and accuracy of contrast material-enhanced moving-table magnetic resonance (MR) angiography and duplex ultrasonography (US) in the assessment of failing bypass grafts. In cases of discrepancy, digital subtraction angiography (DSA) served as the reference standard. MR angiography was performed in 24 consecutive patients with 26 femorotibial or femoropedal bypass grafts. Each revascularized limb was divided into five segments--(i) native arteries proximal to the graft; (ii) proximal anastomosis; (iii) graft course; (iv) distal anastomosis; and (v) native arteries distal to the graft-resulting in 130 vascular segments. Three readers evaluated all MR angiograms for image quality and the presence of failing grafts. The degree of stenosis was compared to the findings of duplex US, and in case of discrepancy, to DSA findings. Two separate analyses were performed with use of DSA only and a combined diagnostic endpoint as the reference standard. Image quality was rated excellent or intermediate in 119 of 130 vascular segments (92%). Venous overlay was encountered in 26 of 130 segments (20%). In only two segments was evaluation of the outflow region not feasible. One hundred seventeen of 130 vascular segments were available for quantitative analysis. In 109 of 117 segments (93%), MR angiography and duplex US showed concordant findings. In the eight discordant segments in seven patients, duplex US overlooked four high-grade stenoses that were correctly identified by MR angiography and confirmed by DSA. Percutaneous transluminal angioplasty was performed in these cases. In no case did MR angiography miss an area of stenosis of sufficient severity to require treatment. Total accuracy for duplex US ranged from 0.90 to 0.97 depending on the reference standard used, whereas MR angiography was completely accurate (1.00) regardless of the standard definition. Our data strongly suggest that the accuracy of MR angiography for identifying failing grafts in the infrapopliteal circulation is equal to that of duplex US and superior to that of duplex US in cases of complex revascularization. MR angiography should be included in routine follow-up of patients undergoing infrapopliteal bypass surgery.

  2. Vascular access site complication in transfemoral coronary angiography between uninterrupted warfarin and heparin bridging.

    PubMed

    Wongcharoen, Wanwarang; Pinyosamosorn, Kittipong; Gunaparn, Siriluck; Boonnayhun, Suchada; Thonghong, Tasalak; Suwannasom, Pannipa; Phrommintikul, Arintaya

    2017-08-01

    Warfarin discontinuation with heparin bridging is a common practice in patients receiving warfarin prior to elective coronary angiography (CAG). The uninterrupted warfarin strategy has been suggested to be alternative option for patients with high thromboembolic risk. Therefore, we aimed to assess the safety of elective transfemoral CAG during uninterrupted warfarin therapy compared to heparin bridging. This study was a randomized open-label design with blinded event evaluation. The 110 consecutive patients (age ≥ 18 years) receiving warfarin before the planned transfemoral CAG were randomly assigned to either heparin bridging or uninterrupted warfarin with targeted INR (2.0-3.0). The primary outcome was the incidence of major vascular access site complications. The baseline characteristics were comparable between two groups (mean age was 60.1 ± 7.8 years, 49 males). The mean INR on the day of CAG of heparin bridging and uninterrupted warfarin groups was 1.2 ± 0.3 and 2.2 ± 0.5 (P < 0.001). The major vascular access site complications occurred in 3 of 55 (5.5%) heparin-bridging patients and in none of 55 uninterrupted warfarin patients (P = 0.243). The total vascular access site complications occurred in 6 (10.9%) heparin-bridging and one (1.8%) uninterrupted warfarin patients (P = 0.113). No patient developed either other bleeding or thromboembolic events during 7 days after CAG. We demonstrated that an uninterrupted warfarin strategy did not increase vascular access site complications in patients undergoing transfemoral CAG compared to heparin bridging therapy. Due to the safety and the ease of uninterrupted warfarin strategy, this approach should be encouraged in patients receiving long-term warfarin who undergo elective transfemoral CAG. © 2017, Wiley Periodicals, Inc.

  3. Incidence and Predictors of reCurrent Restenosis After Drug-coated Balloon Angioplasty for Restenosis of a drUg-eluting Stent: The ICARUS Cooperation.

    PubMed

    Cassese, Salvatore; Xu, Bo; Habara, Seiji; Rittger, Harald; Byrne, Robert A; Waliszewski, Matthias; Pérez-Vizcayno, María José; Gao, Runlin; Kastrati, Adnan; Alfonso, Fernando

    2017-09-12

    The incidence and predictors of recurrent restenosis after drug-coated balloon (DCB) angioplasty for drug-eluting stent (DES) restenosis remain poorly studied. We sought to evaluate the incidence and predictors of recurrent restenosis among participants in randomized controlled trials receiving DCB angioplasty for DES restenosis. The clinical and lesion data of individuals enrolled in 6 randomized controlled trials of DCB angioplasty for DES restenosis were pooled. All patients included in this report were assigned to receive paclitaxel-coated balloon angioplasty with the SeQuent Please DCB (B Braun, Melsungen, Germany). The current analysis focused on participants with available follow-up angiography at 6 to 9 months. The incidence of recurrent restenosis, defined as diameter restenosis ≥ 50% in the in-segment area at follow-up angiography, and its clinical and angiographic predictors were evaluated. A total of 546 patients were combined in a single dataset. Angiographic follow-up at 6 to 9 months was available for 484 patients (88.6%) with 518 treated lesions. Recurrent restenosis was detected in 101 (20.8%) patients. On multivariable analysis, lesion length (OR, 1.58; 95%CI, 1.10-2.26; P=.012 for 5mm increase) and vessel size (OR, 1.42; 95%, 1.12-1.79; P=.003 for 0.5mm reduction) were independently associated with recurrent restenosis. In the largest cohort to date of individuals with angiographic surveillance after DCB angioplasty for DES restenosis, we demonstrated that recurrent restenosis occurs in approximately 1 out of 5 patients. Predictors of recurrent restenosis are increased lesion length and small vessel size. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  4. A comparison of free autologous breast reconstruction with and without the use of laser-assisted indocyanine green angiography: a cost-effectiveness analysis.

    PubMed

    Chatterjee, Abhishek; Krishnan, Naveen M; Van Vliet, Michael M; Powell, Stephen G; Rosen, Joseph M; Ridgway, Emily B

    2013-05-01

    Laser-assisted indocyanine green angiography is a U.S. Food and Drug Administration-approved technology used to assess tissue viability and perfusion. Its use in plastic and reconstructive surgery to assess flap perfusion in autologous breast reconstruction is relatively new. There have been no previous studies evaluating the cost-effectiveness of this new technology compared with the current practice of clinical judgment in evaluating tissue perfusion and viability in free autologous breast reconstruction in patients who have undergone mastectomy. A comprehensive literature review was performed to identify the complication rate of the most common complications with and without laser-assisted indocyanine green angiography in free autologous breast reconstruction after mastectomy. These probabilities were combined with Medicare Current Procedural Terminology provider reimbursement codes (cost) and utility estimates for common complications from a survey of 10 plastic surgeons to fit into a decision model to evaluate the cost-effectiveness of laser-assisted indocyanine green angiography. The decision model revealed a baseline cost difference of $773.66 and a 0.22 difference in the quality-adjusted life-years, yielding an incremental cost-utility ratio of $3516.64 per quality-adjusted life year favoring laser-assisted indocyanine green angiography. Sensitivity analysis showed that using laser-assisted indocyanine green angiography was more cost-effective when the complication rate without using laser-assisted indocyanine green angiography (clinical judgment alone) was 4 percent or higher. The authors' study demonstrates that laser-assisted indocyanine green angiography is a cost-effective technology under the most stringent acceptable thresholds when used in immediate free autologous breast reconstruction.

  5. Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline

    PubMed Central

    2013-01-01

    We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography images because of complex nonrigid motions that exist in this type of angiography images. Multiresolution and iterative algorithms are proposed to cope with this problem, but these algorithms are associated with high computational cost which makes them not acceptable for real-time clinical applications. In this paper we propose a nonrigid image registration algorithm for coronary angiography images that is significantly faster than multiresolution and iterative blocking methods and outperforms competing algorithms evaluated on the same data sets. This algorithm is based on a sparse set of matched feature point pairs and the elastic registration is performed by means of multilevel B-spline image warping. Experimental results with several clinical data sets demonstrate the effectiveness of our approach. PMID:23971026

  6. Non-invasive coronary angiography for patients with acute atypical chest pain discharged after negative screening including maximal negative treadmill stress test. A prospective study.

    PubMed

    Bonello, L; Armero, S; Jacquier, A; Com, O; Sarran, A; Sbragia, P; Panuel, M; Arques, S; Paganelli, F

    2009-05-01

    Among patients admitted in the emergency department for acute atypical chest pain those with an acute coronary syndrome (ACS) who are mistakenly discharged home have high mortality. A recent retrospective study has demonstrated that multislice computed tomography (MSCT) coronary angiography could improve triage of these patients. We aimed to prospectively confirm these data on patients with a negative screening including maximal treadmill stress. 30 patients discharged from the emergency department after negative screening for an ACS were included. All patients underwent MSCT angiography of the coronary artery. Patients with coronary atheroma on MSCT had an invasive coronary angiography to confirm these findings. Seven patients (23%) had obstructive coronary artery disease on MSCT. Invasive coronary angiography (ICA) confirmed the diagnosis in all patients. In patients with no previously known coronary artery disease admitted to the emergency department with atypical acute chest pain and discharged after negative screening, including maximal treadmill stress test, MSCT coronary angiography is useful for the diagnosis of obstructive coronary artery disease.

  7. Application of Micromirror in Microsurgical Clipping to the Intracranial Aneurysms.

    PubMed

    Zhao, Chao; Ma, Zhiguo; Zhang, Yuhai; Mou, Shanling; Yang, Yunxue; Yang, Yonglin; Sun, Guoqing; Yao, Weicheng

    2018-05-01

    The aim of the study was to explore the values and disadvantages of micromirror in the intracranial aneurysm clipping surgery. Micromirror was used to assist microsurgical clipping to 36 intracranial aneurysms in 31 patients, of which 3 were carotid-ophthalmic artery aneurysms, 3 were anterior choroidal artery aneurysms, 11 were posterior communicating artery aneurysms, 7 were middle cerebral artery aneurysms, 10 were anterior communicating artery or anterior cerebral artery aneurysms, and the rest were a posterior cerebral artery aneurysm and a posterior inferior cerebellar artery aneurysm. The micromirror was used before and after clipping to observe the anatomic features of necks hidden behind and medial to aneurysms, to visualize surrounding neurovascular structures, and to verify the optimal clipping position. Intraoperative indocyanine green fluorescein angiography, postoperative computerized tomography angiography, and digital subtraction angiography confirmed the success of sufficient clipping. Intraoperative indocyanine green angiography, postoperative computerized tomography angiography , or digital subtraction angiography were performed and showed no case of wrong or insufficient clipping of aneurysm. Micromirror-assisted microsurgical clipping to the intracranial aneurysm is safe, sufficient, convenient, and practical.

  8. New insights into diabetic retinopathy by OCT angiography.

    PubMed

    Liu, Guodong; Xu, Ding; Wang, Fang

    2018-06-04

    Diabetic retinopathy (DR) is one of the most common diabetic complications, which has become a leading cause for vision loss, mainly because of macular edema and vitreous hemorrhage. Optical coherence tomography (OCT) angiography is a novel technique to visualize vascular changes including microaneurysm, non-perfusion area, intraretinal microvascular abnormalities, and neovascularization. Recently, it is possible to quantify vascular density, foveal avascular zone area, non-perfusion area objectively using OCT angiography. In addition, OCT angiography also provides an alternative method to evaluate the effect of anti-vascular endothelial growth factor (VEGF) treatments by providing high resolution images of macular microcirculatory abnormalities. Thus OCT angiography is an effective method to investigate the vascular changes of the disease, and can also be potentially applied in the diagnosis, treatment, and follow up of DR. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Indocyanine green angiography of juvenile X-linked retinoschisis.

    PubMed

    Souied, Eric H; Goritsa, Anna; Querques, Giuseppe; Coscas, Gabriel; Soubrane, Gisele

    2005-09-01

    In juvenile X-linked retinoschisis (XLRS), fluorescein angiography is usually unremarkable and contributes poorly to the diagnosis. However, indocyanine green (ICG) angiography features in eyes that are affected with XLRS were not yet described. Retrospective observational case series. A complete ophthalmologic examination that included ICG angiography was performed on three unrelated male patients (six eyes) who were 15, 22, and 48 years old. A distinct hyperfluorescent stellate pattern in the macular area that was associated with radial lines of hypofluorescence that were centered on the foveola was observed on the early phase of ICG examination (six of six eyes). This feature disappeared on the late phase of ICG examination. On these six XLRS eyes, early phases of ICG examination revealed an unusual radial aspect on the macula. This finding suggests that ICG angiography may be useful for the diagnosis of XLRS.

  10. Fairness in the coronary angiography queue.

    PubMed

    Alter, D A; Basinski, A S; Cohen, E A; Naylor, C D

    1999-10-05

    Since waiting lists for coronary angiography are generally managed without explicit queuing criteria, patients may not receive priority on the basis of clinical acuity. The objective of this study was to examine clinical and nonclinical determinants of the length of time patients wait for coronary angiography. In this single-centre prospective cohort study conducted in the autumn of 1997, 357 consecutive patients were followed from initial triage until a coronary angiography was performed or an adverse cardiac event occurred. The referring physicians' hospital affiliation (physicians at Sunnybrook & Women's College Health Sciences Centre, those who practice at another centre but perform angiography at Sunnybrook and those with no previous association with Sunnybrook) was used to compare processes of care. A clinical urgency rating scale was used to assign a recommended maximum waiting time (RMWT) to each patient retrospectively, but this was not used in the queuing process. RMWTs and actual waiting times for patients in the 3 referral groups were compared; the influence clinical and nonclinical variables had on the actual length of time patients waited for coronary angiography was assessed; and possible predictors of adverse events were examined. Of 357 patients referred to Sunnybrook, 22 (6.2%) experienced adverse events while in the queue. Among those who remained, 308 (91.9%) were in need of coronary angiography; 201 (60.0%) of those patients received one within the RMWT. The length of time to angiography was influenced by clinical characteristics similar to those specified on the urgency rating scale, leading to a moderate agreement between actual waiting times and RMWTs (kappa = 0.53). However, physician affiliation was a highly significant (p < 0.001) and independent predictor of waiting time. Whereas 45.6% of the variation in waiting time was explained by all clinical factors combined, 9.3% of the variation was explained by physician affiliation alone. Informal queuing practices for coronary angiography do reflect clinical acuity, but they are also influenced by nonclinical factors, such as the nature of the physicians' association with the catheterization facility.

  11. Pulmonary Angiography and Embolization for Severe Hemoptysis Due to Cavitary Pulmonary Tuberculosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanyika, Charles; Corr, Peter; Royston, Duncan

    1999-11-15

    Purpose: To identify the role of pulmonary angiography in the diagnosis and treatment of severe hemoptysis due to cavitary pulmonary tuberculosis. Methods: Selective pulmonary angiography was performed on eight patients with severe hemoptysis uncontrolled by previous bronchial and systemic arterial embolization. Results: Three (38%) patients had Rasmussen aneurysms, which were successfully embolized with steel coils. Five patients demonstrated pulmonary arterial hypoperfusion in the diseased lung. Conclusions: We recommend pulmonary angiography in cavitary tuberculous patients with severe hemoptysis who do not respond to systemic arterial embolization. Rasmussen aneurysms are effectively treated by steel coil occlusion.

  12. Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry.

    PubMed

    Vanhaebost, Jessica; Ducrot, Kewin; de Froidmont, Sébastien; Scarpelli, Maria Pia; Egger, Coraline; Baumann, Pia; Schmit, Gregory; Grabherr, Silke; Palmiere, Cristian

    2017-02-01

    The aim of this study was to assess whether the identification of pathological myocardial enhancement at multiphase postmortem computed tomography angiography was correlated with increased levels of troponin T and I in postmortem serum from femoral blood as well as morphological findings of myocardial ischemia. We further aimed to investigate whether autopsy cases characterized by increased troponin T and I concentrations as well as morphological findings of myocardial ischemia were also characterized by pathological myocardial enhancement at multiphase postmortem computed tomography angiography. Two different approaches were used. In one, 40 forensic autopsy cases that had pathological enhancement of the myocardium (mean Hounsfield units ≥95) observed at postmortem angiography were retrospectively selected. In the second approach, 40 forensic autopsy cases that had a cause of death attributed to acute myocardial ischemia were retrospectively selected. The preliminary results seem to indicate that the identification of a pathological enhancement of the myocardium at postmortem angiography is associated with the presence of increased levels of cardiac troponins in postmortem serum and morphological findings of ischemia. Analogously, a pathological enhancement of the myocardium at postmortem angiography can be retrospectively found in the great majority of autopsy cases characterized by increased cardiac troponin levels in postmortem serum and morphological findings of myocardial ischemia. Multiphase postmortem computed tomography angiography is a useful tool in the postmortem setting for investigating ischemically damaged myocardium.

  13. Ultra-wide-field angiography improves the detection and classification of diabetic retinopathy.

    PubMed

    Wessel, Matthew M; Aaker, Grant D; Parlitsis, George; Cho, Minhee; D'Amico, Donald J; Kiss, Szilárd

    2012-04-01

    To evaluate patients with diabetic retinopathy using ultra-wide-field fluorescein angiography and to compare the visualized retinal pathology with that seen on an overly of conventional 7 standard field (7SF) imaging. Two hundred and eighteen eyes of 118 diabetic patients who underwent diagnostic fluorescein angiography using the Optos Optomap Panoramic 200A imaging system were included. The visualized area of the retina, retinal nonperfusion, retinal neovascularization, and panretinal photocoagulation were quantified by two independent masked graders. The respective areas identified on the ultra-wide-field fluorescein angiography image were compared with an overly of a modified 7SF image as outlined in the Early Treatment Diabetic Retinopathy Study. Ultra-wide-field fluorescein angiograms imaging, on average, demonstrated 3.2 times more total retinal surface area than 7SF. When compared with 7SF, ultra-wide-field fluorescein angiography showed 3.9 times more nonperfusion (P < 0.001), 1.9 times more neovascularization (P = 0.036), and 3.8 times more panretinal photocoagulation (P < 0.001). In 22 eyes (10%), ultra-wide-field fluorescein angiography demonstrated retinal pathology (including nonperfusion and neovascularization) not evident in an 7SF overly. Compared with conventional 7SF imaging, ultra-wide-field fluorescein angiography reveals significantly more retinal vascular pathology in patients with diabetic retinopathy. Improved retinal visualization may alter the classification of diabetic retinopathy and may therefore influence follow-up and treatment of these patients.

  14. Intraoperative bypass graft angiography: cooperation between cardiologist and surgeons in the operation room for optimal postoperative results -- is this the way for the future?

    PubMed

    Shrestha, M; Bara, C; Khaladj, N; Kamiya, H; Hagl, C; Kallenbach, K; Zhang, R; Klima, U; Haverich, A

    2007-09-01

    To confirm the quality of total arterial CABG carried out using the left internal thoracic artery (LITA) and a radial artery (RA) T-graft and distal anastomoses immediately in the OR, we developed a new technique using intraoperative graft angiography. A 5-Fr sheath is inserted in the proximal radial artery stump, through which a catheter for LITA angiography is later introduced. From July 2004 to March 2005, 23 patients underwent total arterial CABG with the T-graft and intraoperative graft angiography. On-pump CABG was performed in 22 patients and off-pump CABG in 1 patient. Mean procedure time for the angiography was 13.7 +/- 7.3 minutes, and mean fluoroscopy time was 6.2 +/- 4.6 minutes. In two patients, the RA-marginal artery side-to-side anastomosis was stenosed and had to be revised as demonstrated by graft angiography. In one patient, the RA was kinked and in another, there was a kinking of the LITA. In both cases, kinking was corrected. The remaining anastomoses were seen to have unobstructed flow with no evidence of stenosis. Intraoperative graft angiography can be performed in patients undergoing total arterial CABG. This concept of intraoperative cooperation between an interventional cardiologist and surgeons could significantly improve the operative outcome in CABG surgery.

  15. Effect of Vascular Access Site Choice on Radiation Exposure During Coronary Angiography: The REVERE Trial (Randomized Evaluation of Vascular Entry Site and Radiation Exposure).

    PubMed

    Pancholy, Samir B; Joshi, Pankaj; Shah, Sanjay; Rao, Sunil V; Bertrand, Olivier F; Patel, Tejas M

    2015-08-17

    This study sought to perform a randomized noninferiority trial of radiation exposure during cardiac catheterization comparing femoral access (FA) with left radial access (LRA) and right radial access (RRA). Increased radiation exposure with radial approach compared with femoral approach remains a controversial issue. This study randomized 1,493 patients undergoing cardiac catheterization at a tertiary care center to FA, LRA, and RRA in a 1:1:1 fashion. The primary endpoint was air kerma. The secondary endpoints included dose-area product, fluoroscopy time and operator dose per procedure, number of cineangiograms, and number of catheters. Baseline and procedural characteristics were similar among groups. No significant differences were observed in air kerma (medians: FA: 421 mGy [interquartile range (IQR): 337 to 574 mGy], LRA: 454 mGy [IQR: 331 to 643 mGy], and RRA: 483 mGy [IQR: 382 to 592 mGy], p = 0.146), dose-area product (medians: FA: 25.5 Gy cm(2) [IQR: 19.6 to 34.5 Gy cm(2)], LRA: 26.6 Gy cm(2) [IQR: 19.5 to 37.5 Gy cm(2)], and RRA: 27.7 Gy cm(2) [IQR: 21.9 to 34.4 Gy cm(2)], p = 0.40), or fluoroscopy time (medians: FA: 1.3 min [IQR: 1.0 to 1.7 min], LRA: 1.3 min [IQR: 1.0 to 1.7 min], and RRA: 1.32 min [IQR: 1.0 to 1.7 min], p = 0.19) among the 3 access sites. Median operator exposure was higher in the LRA group (3 mrem [IQR: 2 to 5 mrem], p = 0.001 vs. FA, and p = 0.0001 vs. RRA) compared with the FA (2 mrem [IQR: 2 to 4 mrem] and RRA groups (3 mrem [IQR: 2 to 5 mrem]). Radiation exposure to patients was similar during diagnostic coronary angiography with FA, RRA, and LRA. However, LRA was associated with significantly higher operator radiation exposure than were FA and RRA procedures. (Randomized Evaluation of Vascular Entry Site and Radiation Exposure [REVERE]; NCT01677481). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Role of multidetector computed tomography in the diagnosis and management of patients attending the rapid access chest pain clinic, The Scottish computed tomography of the heart (SCOT-HEART) trial: study protocol for randomized controlled trial

    PubMed Central

    2012-01-01

    Background Rapid access chest pain clinics have facilitated the early diagnosis and treatment of patients with coronary heart disease and angina. Despite this important service provision, coronary heart disease continues to be under-diagnosed and many patients are left untreated and at risk. Recent advances in imaging technology have now led to the widespread use of noninvasive computed tomography, which can be used to measure coronary artery calcium scores and perform coronary angiography in one examination. However, this technology has not been robustly evaluated in its application to the clinic. Methods/design The SCOT-HEART study is an open parallel group prospective multicentre randomized controlled trial of 4,138 patients attending the rapid access chest pain clinic for evaluation of suspected cardiac chest pain. Following clinical consultation, participants will be approached and randomized 1:1 to receive standard care or standard care plus ≥64-multidetector computed tomography coronary angiography and coronary calcium score. Randomization will be conducted using a web-based system to ensure allocation concealment and will incorporate minimization. The primary endpoint of the study will be the proportion of patients diagnosed with angina pectoris secondary to coronary heart disease at 6 weeks. Secondary endpoints will include the assessment of subsequent symptoms, diagnosis, investigation and treatment. In addition, long-term health outcomes, safety endpoints, such as radiation dose, and health economic endpoints will be assessed. Assuming a clinic rate of 27.0% for the diagnosis of angina pectoris due to coronary heart disease, we will need to recruit 2,069 patients per group to detect an absolute increase of 4.0% in the rate of diagnosis at 80% power and a two-sided P value of 0.05. The SCOT-HEART study is currently recruiting participants and expects to report in 2014. Discussion This is the first study to look at the implementation of computed tomography in the patient care pathway that is outcome focused. This study will have major implications for the management of patients with cardiovascular disease. Trial registration ClinicalTrials.gov Identifier: NCT01149590 PMID:23036114

  17. The optimal imaging strategy for patients with stable chest pain: a cost-effectiveness analysis.

    PubMed

    Genders, Tessa S S; Petersen, Steffen E; Pugliese, Francesca; Dastidar, Amardeep G; Fleischmann, Kirsten E; Nieman, Koen; Hunink, M G Myriam

    2015-04-07

    The optimal imaging strategy for patients with stable chest pain is uncertain. To determine the cost-effectiveness of different imaging strategies for patients with stable chest pain. Microsimulation state-transition model. Published literature. 60-year-old patients with a low to intermediate probability of coronary artery disease (CAD). Lifetime. The United States, the United Kingdom, and the Netherlands. Coronary computed tomography (CT) angiography, cardiac stress magnetic resonance imaging, stress single-photon emission CT, and stress echocardiography. Lifetime costs, quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratios. The strategy that maximized QALYs and was cost-effective in the United States and the Netherlands began with coronary CT angiography, continued with cardiac stress imaging if angiography found at least 50% stenosis in at least 1 coronary artery, and ended with catheter-based coronary angiography if stress imaging induced ischemia of any severity. For U.K. men, the preferred strategy was optimal medical therapy without catheter-based coronary angiography if coronary CT angiography found only moderate CAD or stress imaging induced only mild ischemia. In these strategies, stress echocardiography was consistently more effective and less expensive than other stress imaging tests. For U.K. women, the optimal strategy was stress echocardiography followed by catheter-based coronary angiography if echocardiography induced mild or moderate ischemia. Results were sensitive to changes in the probability of CAD and assumptions about false-positive results. All cardiac stress imaging tests were assumed to be available. Exercise electrocardiography was included only in a sensitivity analysis. Differences in QALYs among strategies were small. Coronary CT angiography is a cost-effective triage test for 60-year-old patients who have nonacute chest pain and a low to intermediate probability of CAD. Erasmus University Medical Center.

  18. Use of the 2.8 French Progreat microcatheter in diagnostic cerebral angiography.

    PubMed

    Griauzde, Julius; Gemmete, Joseph J; Shastri, Ravi; Pandey, Aditya S; Chaudhary, Neeraj

    2017-01-01

    Tortuous vascular anatomy poses a significant challenge to performing diagnostic cerebral angiography. To report a new cerebral angiography technique for overcoming tortuous aortic and supra-aortic anatomy using a 2.8 French (F) Progreat microcatheter (0.028 inch (internal diameter) (Terumo; Somerset, New Jersey, USA) to obtain a diagnostic cerebral angiogram. A retrospective analysis of consecutive cases undergoing diagnostic cerebral angiography at our institution between 1 January 2013 and 30 November 2015 in which a 2.8F Progreat microcatheter was used. Clinical and operative notes were reviewed and correlated with imaging. Radiologic imaging, including CT, MRI, and digital subtraction angiography, was reviewed. Neurologic, systemic, and local complications were recorded on the basis of clinical follow-up results after each angiographic examination. Events that occurred within 24 h of the angiography were considered to be complications of the procedure. Initial attempts at catheterization of the target vessel with various 4F and 5F catheters were unsuccessful owing to tortuosity, atherosclerotic disease, or occlusion of the catheter in the target vessel. Microcatheterization of the target vessel was successful in 59/62 (95%) target vessels. A diagnostic cerebral angiogram with a power injection was obtained in 59 (100%) of the successfully catheterized vessels. In one case, angiography proceeded to aneurysm coiling after over-the-wire exchange. In two cases, angiography proceeded to mechanical thrombectomy after over-the-wire exchange. No procedural complications were seen. The 2.8F Progreat microcatheter can be used to obtain a diagnostic cerebral angiogram in patients with anatomic challenges limiting catheterization by standard techniques. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction

    PubMed Central

    Chae, Michael P.; Hunter-Smith, David J.

    2015-01-01

    Background The high incidence of breast cancer and growing number of breast cancer patients undergoing mastectomy has led to breast reconstruction becoming an important part of holistic treatment for these patients. In planning autologous reconstructions, preoperative assessment of donor site microvascular anatomy with advanced imaging modalities has assisted in the appropriate selection of flap donor site, individual perforators, and lead to an overall improvement in flap outcomes. In this review, we compare the accuracy of fluorescent angiography, computed tomographic angiography (CTA), and magnetic resonance angiography (MRA) and their impact on clinical outcomes. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE was undertaken. Results Fluorescent angiography is technically limited by its inability to evaluate deep-lying perforators and hence, it has a minimal role in the preoperative setting. However, it may be useful intraoperatively in evaluating microvascular anastomotic patency and the mastectomy skin perfusion. CTA is currently widely considered the standard, due to its high accuracy and reliability. Multiple studies have demonstrated its ability to improve clinical outcomes, such as operative length and flap complications. However, concerns surrounding exposure to radiation and nephrotoxic contrast agents exist. MRA has been explored, however despite recent advances, the image quality of MRA is considered inferior to CTA. Conclusions Preoperative imaging is an essential component in planning autologous breast reconstruction. Fluorescent angiography presents minimal role as a preoperative imaging modality, but may be a useful intraoperative adjunct to assess the anastomosis and the mastectomy skin perfusion. Currently, CTA is the gold standard preoperatively. MRA has a role, particularly for women of younger age, iodine allergy, and renal impairment. PMID:26005648

  20. Literature review of non-operative management of patients with blunt splenic injury: impact of splenic artery embolization

    PubMed Central

    Sosada, Krystyn; Piecuch, Jerzy

    2014-01-01

    Splenic injuries constitute the most common injuries accompanying blunt abdominal traumas. Non-operative treatment is currently the standard for treating hemodynamically stable patients with blunt splenic injuries. The introduction of splenic angiography has increased the possibility of non-operative treatment for patients who, in the past, would have qualified for surgery. This cohort includes mainly patients with severe splenic injuries and with active bleeding. The results have indicated that applying splenic angioembolization reduces the frequency of non-operative treatment failure, especially in severe splenic injuries; however, it is still necessary to perform prospective, randomized clinical investigations. PMID:25337151

  1. Literature review of non-operative management of patients with blunt splenic injury: impact of splenic artery embolization.

    PubMed

    Sosada, Krystyn; Wiewióra, Maciej; Piecuch, Jerzy

    2014-09-01

    Splenic injuries constitute the most common injuries accompanying blunt abdominal traumas. Non-operative treatment is currently the standard for treating hemodynamically stable patients with blunt splenic injuries. The introduction of splenic angiography has increased the possibility of non-operative treatment for patients who, in the past, would have qualified for surgery. This cohort includes mainly patients with severe splenic injuries and with active bleeding. The results have indicated that applying splenic angioembolization reduces the frequency of non-operative treatment failure, especially in severe splenic injuries; however, it is still necessary to perform prospective, randomized clinical investigations.

  2. Indocyanine green angiography in patients with human T cell-lymphotropic virus type 1 uveitis.

    PubMed

    Sakurai, Toshiya; Yukawa, Eiichi; Hara, Yoshiaki; Miyata, Norio; Mochizuki, Manabu

    2002-02-01

    To determine the indocyanine green (ICG) angiographic features and to evaluate the choroidal involvement of human T-cell lymphotropic virus type 1 (HTLV-1)-associated uveitis. We performed ICG angiography using scanning laser ophthalmoscopy in 54 eyes of 27 patients (8 men and 19 women) diagnosed with HTLV-1 uveitis. The patient's mean age was 51.5 years with a range of 24-65 years. The early phase of ICG angiography revealed ICG leakage from the choroidal vessels in the posterior pole, hyperfluorescent spots that which were not detected with fluorescein angiography, and small hypofluorescent lesions in the macula which most likely corresponded to microcirculatory disturbances in the choriocapillaris. We suggest that the ICG angiographic findings reflect choroidal lesions such as infiltration with leukocytes and edema. ICG angiography may provide useful information on choroidopathy in HTLV-1 uveitis.

  3. The Modification of Fluorescein Angiography and Its Applications in Age-Related Macular Degeneration and Polypoidal Choroidal Vasculopathy.

    PubMed

    Peng, Qing; Chen, Yutong; Hua, Rui

    2018-06-07

    To establish a novel retinal angiography method, red-free angiography (RFA), to investigate retinal changes in age-related macular degeneration (AMD) and polypoidal choroidal vasculopathy (PCV). Following the venous phase of fundus fluorescein angiography (FFA), the detection mode was switched to red-free reflectance to acquire RFA images using the same parameters. RFA showed subretinal fluid, polyps, and outer retinal tubulation, with a higher definition than the FFA and red-free reflectance results. The absorption coefficients in RFA provided more detailed images for AMD and PCV diagnosis. RFA is therefore a promising approach to supplement FFA. © 2018 S. Karger AG, Basel.

  4. SENSITIVITY AND SPECIFICITY OF DETECTING POLYPOIDAL CHOROIDAL VASCULOPATHY WITH EN FACE OPTICAL COHERENCE TOMOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    de Carlo, Talisa E; Kokame, Gregg T; Kaneko, Kyle N; Lian, Rebecca; Lai, James C; Wee, Raymond

    2018-03-20

    Determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis with structural en face optical coherence tomography (OCT) and OCT angiography (OCTA). Retrospective review of the medical records of eyes diagnosed with PCV by indocyanine green angiography with review of diagnostic testing with structural en face OCT and OCTA by a trained reader. Structural en face OCT, cross-sectional OCT angiograms alone, and OCTA in its entirety were reviewed blinded to the findings of indocyanine green angiography and each other to determine if they could demonstrate the PCV complex. Sensitivity and specificity of PCV diagnosis was determined for each imaging technique using indocyanine green angiography as the ground truth. Sensitivity and specificity of structural en face OCT were 30.0% and 85.7%, of OCT angiograms alone were 26.8% and 96.8%, and of the entire OCTA were 43.9% and 87.1%, respectively. Sensitivity and specificity were improved for OCT angiograms and OCTA when looking at images taken within 1 month of PCV diagnosis. Sensitivity of detecting PCV was low using structural en face OCT and OCTA but specificity was high. Indocyanine green angiography remains the gold standard for PCV detection.

  5. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    PubMed

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  6. X-ray angiography systems.

    PubMed

    1993-11-01

    Despite the emergence of several alternative angiographic imaging techniques (i.e., magnetic resonance imaging, computed tomography, and ultrasound angiography), x-ray angiography remains the predominant vascular imaging modality, generating over $4 billion in revenue a year in U.S. hospitals. In this issue, we provide a brief overview of the various angiographic imaging techniques, comparing them with x-ray angiography, and discuss the clinical aspects of x-ray vascular imaging, including catheterization and clinical applications. Clinical, cost, usage, and legal issues related to contrast media are discussed in "Contrast Media: Ionic versus Nonionic and Low-osmolality Agents." We also provide a technical overview and selection guidance for a basic x-ray angiography imaging system, including the gantry and table system, x-ray generator, x-ray tube, image intensifier, video camera and display monitors, image-recording devices, and digital acquisition and processing systems. This issue also contains our Evaluation of the GE Advantx L/C cardiac angiography system and the GE Advantx AFM general-purpose angiography system; the AFM can be used for peripheral, pulmonary, and cerebral vascular studied, among others, and can also be configured for cardiac angiography. Many features of the Advantx L/C system, including generator characteristics and ease of use, also apply to the Advantx AFM as configured for cardiac angiography. Our ratings are based on the systems' ability to provide the best possible image quality for diagnosis and therapy while minimizing patient and personnel exposure to radiation, as well as its ability to minimize operator effort and inconvenience. Both units are rated Acceptable. In the Guidance Section, "Radiation Safety and Protection," we discuss the importance of keeping patient and personnel exposures to radiation as low as reasonably possible, especially in procedures such as cardiac catheterization, angiographic imaging for special procedures, and interventional radiology, which produce among the highest radiation exposure of all x-ray imaging techniques. We also provide recommendations for minimizing personnel and patient exposures to radiation. For more information about x-ray angiography systems and similar devices, as well as for additional perspectives on which we based this study, see the following Health Devices Evaluations: "Mobile C-arm Units" (19[8], August 1990) and "Noninvasive Electronic Quality Control Devices for X-ray Generator Testing" (21[6-7], June-July 1992).(ABSTRACT TRUNCATED AT 400 WORDS)

  7. Digital Subtraction Angiography or Computed Tomography Angiography in the Preoperative Evaluation of Lower Limb Peripheral Artery Disease - A Comparative Analysis.

    PubMed

    Dias-Neto, Marina; Marques, Catarina; Sampaio, Sérgio

    2017-01-01

    For several years, digital subtraction angiography (DSA) was considered the gold standard method for the evaluation of PAD patients. This is an invasive technique and allows a good evaluation of collaterals and the vessel lumen, even in cases with associated calcification. Nevertheless, recent technical development of computed tomography angiography (CTA) has improved its specificity and sensibility, besides the fact that CTA is a fast and non-invasive procedure. To characterize a cohort of lower limb PAD patients and clarify if there are differences among the patients preoperatively evaluated by DSA or CTA. This retrospective study focused on PAD patients with a Rutherford classification ≥ 3 and submitted to intervention (endovascular revascularization or open surgery). The CTA group included all patients submitted to this method as their preoperative exam, between March 2009 and April 2017. In the same period of time, patients submitted to DSA as their preoperative exam, were randomly selected. The exclusion criteria were: realization of the exam for a different diagnosis than PAD, amputation not preceded by revascularization, absence of intervention during a period of 1 year after the realization of the exam. The groups were compared upon the type of surgery (open vs endovascular), number of revascularization sectors, reintervention, amputation, mortality and length of hospital stay. 34 CTA patients and 71 DSA patients were included. The groups were demographically and clinically homogeneous. In what regards to arterial lesions, the DSA group showed more often lesions of the distal sector with TASC C or D classification (25% in DSA group and 0% in CTA group; p=0,001), as well as scarcity of runoff vessels (0 or 1 in 72% of DSA patients group and 26% in CTA group; p=0.001). There were no differences about the endovascular and open surgery ratio (1.8 to CTA and 1.4 to DSA; p=0.305), reintervention rates (21% CTA and 16% DSA; p=0.517), major amputation (9% CTA and 11% DSA; p=1), minor amputation (9% CTA and 16% DSA; p=0.541), mortality (18% CTA and 23% DSA; p=0,602), or length of hospital stay (median and (interquartile range) of 14 (27) for CTA and 14 (17) for DSA; p=0.933). CTA seems to be a method for morphological and therapeutic planning of PAD that is non-inferior to DSA.

  8. Transarterial chemoembolization plus or minus intravenous bevacizumab in the treatment of hepatocellular cancer: A pilot study

    PubMed Central

    2012-01-01

    Background Stimulation of vascular endothelial growth factor (VEGF) has been observed following transarterial chemoembolization (TACE) in hepatocellular cancer (HCC) and may contribute to tumor regrowth. This pilot study examined whether intravenous (IV) bevacizumab, a monoclonal antibody against VEGF, could inhibit neovessel formation after TACE. Methods 30 subjects with HCC undergoing TACE at a single academic institution were randomized with a computer-generated allocation in a one to one ratio to either bevacizumab at a dose of 10 mg/kg IV every 14 days beginning 1 week prior to TACE (TACE-BEV arm) or observation (TACE-O arm). Angiography was performed with TACE at day 8, and again at weeks 10 and 14. Repeat TACE was performed at week 14 if indicated. TACE-BEV subjects were allowed to continue bevacizumab beyond week 16. TACE-O subjects were allowed to cross-over to bevacizumab at week 16 in the setting of progressive disease. The main outcome measure was a comparison of neovessel formation by serial angiography. Secondary outcome measures were progression free survival (PFS) at 16 weeks, overall survival (OS), bevacizumab safety, and an analysis of VEGF levels before and after TACE with and without bevacizumab. Results Among the 30 subjects enrolled, 9 of 15 randomized to the TACE-O arm and 14 of 15 randomized to the TACE-BEV arm completed all 3 angiograms. At week 14, 3 of 9 (33%) TACE-O subjects and 2 of 14 (14%) TACE-BEV subjects demonstrated neovascularity. The PFS at 16 weeks was 0.19 in the TACE-O arm and 0.79 in the TACE-BEV arm (p = 0.021). The median OS was 61 months in the TACE-O arm and 49 months in the TACE-BEV arm (p = 0.21). No life-threatening bevacizumab-related toxicities were observed. There were no substantial differences in bevacizumab pharmacokinetics compared to historical controls. Bevacizumab attenuated the increase in VEGF observed post-TACE. Conclusions IV bevacizumab was well tolerated in selected HCC subjects undergoing TACE, and appeared to diminish neovessel formation at week 14. Trial registration ClinicalTrials.gov NCT00049322. PMID:22244160

  9. Ezetimibe in Combination With Statins Ameliorates Endothelial Dysfunction in Coronary Arteries After Stenting: The CuVIC Trial (Effect of Cholesterol Absorption Inhibitor Usage on Target Vessel Dysfunction After Coronary Stenting), a Multicenter Randomized Controlled Trial.

    PubMed

    Takase, Susumu; Matoba, Tetsuya; Nakashiro, Soichi; Mukai, Yasushi; Inoue, Shujiro; Oi, Keiji; Higo, Taiki; Katsuki, Shunsuke; Takemoto, Masao; Suematsu, Nobuhiro; Eshima, Kenichi; Miyata, Kenji; Yamamoto, Mitsutaka; Usui, Makoto; Sadamatsu, Kenji; Satoh, Shinji; Kadokami, Toshiaki; Hironaga, Kiyoshi; Ichi, Ikuyo; Todaka, Koji; Kishimoto, Junji; Egashira, Kensuke; Sunagawa, Kenji

    2017-02-01

    We sought to investigate whether treatment with ezetimibe in combination with statins improves coronary endothelial function in target vessels in coronary artery disease patients after coronary stenting. We conducted a multicenter, prospective, randomized, open-label, blinded-end point trial among 11 cardiovascular treatment centers. From 2011 to 2013, 260 coronary artery disease patients who underwent coronary stenting were randomly allocated to 2 arms (statin monotherapy, S versus ezetimibe [10 mg/d]+statin combinational therapy, E+S). We defined target vessel dysfunction as the primary composite outcome, which comprised target vessel failure during treatment and at the 6- to 8-month follow-up coronary angiography and coronary endothelial dysfunction determined via intracoronary acetylcholine testing performed in cases without target vessel failure at the follow-up coronary angiography. Coadministration of ezetimibe with statins further lowered low-density lipoprotein cholesterol levels (83±23 mg/dL in S versus 67±23 mg/dL in E+S; P<0.0001), with significant decreases in oxidized low-density lipoprotein and oxysterol levels. Among patients without target vessel failure, 46 out of 89 patients (52%) in the S arm and 34 out of 96 patients (35%) in the E+S arm were found to have coronary endothelial dysfunction (P=0.0256), and the incidence of target vessel dysfunction at follow-up was significantly decreased in the E+S arm (69/112 (62%) in S versus 47/109 (43%) in E+S; P=0.0059). A post hoc analysis of post-treatment low-density lipoprotein cholesterol-matched subgroups revealed that the incidence of both target vessel dysfunction and coronary endothelial dysfunction significantly decreased in the E+S arm, with significant reductions in oxysterol levels. The CuVIC trial (Effect of Cholesterol Absorption Inhibitor Usage on Target Vessel Dysfunction after Coronary Stenting) has shown that ezetimibe with statins, compared with statin monotherapy, improves functional prognoses, ameliorating endothelial dysfunction in stented coronary arteries, and was associated with larger decreases in oxysterol levels. © 2016 American Heart Association, Inc.

  10. Mesenteric angiography

    MedlinePlus

    ... Arteriogram - abdomen; Mesenteric angiogram Images Mesenteric arteriography References Kaufman JA. Fundamentals of angiography. In: Kaufman JA, Lee MJ, eds. Vascular and Interventional Radiology: ...

  11. Indocyanine green laser angiography improves deep inferior epigastric perforator flap outcomes following abdominal suction lipectomy.

    PubMed

    Casey, William J; Connolly, Katharine A; Nanda, Alisha; Rebecca, Alanna M; Perdikis, Galen; Smith, Anthony A

    2015-03-01

    The reliability of deep inferior epigastric artery perforator (DIEP) flap reconstruction following abdominal liposuction is controversial. The authors' early cases were technically successful; however, they experienced high partial flap loss and fat necrosis rates. The authors sought to compare DIEP flap outcomes in the setting of prior liposuction after the use of intraoperative indocyanine green angiography compared to when flaps were assessed on clinical grounds alone. A retrospective review of a consecutive series of DIEP flaps following liposuction at a single institution was performed, comparing those evaluated on clinical grounds alone and those in which indocyanine green angiography was used intraoperatively. Outcomes measured included anastomotic complications, total flap loss, partial flap loss, fat necrosis, and postoperative abdominal wounds. Thirteen DIEP flaps following prior liposuction were performed on 11 patients from July of 2003 through January of 2014. All patients had preoperative imaging with duplex ultrasound or computed tomographic angiography to analyze perforator suitability before surgical exploration. Seven flaps were evaluated intraoperatively on clinical grounds alone. Six flaps were assessed and modified based on indocyanine green angiography. All flaps were successful; however, partial flap loss and fat necrosis rates dropped from 71.4 percent to 0 percent when indocyanine green angiography was used intraoperatively (p = 0.02). Indocyanine green angiography is an excellent vascular imaging modality for intraoperative use to assess flap perfusion, and improves outcomes in DIEP flaps when harvested after prior abdominal suction lipectomy.

  12. Chamber dimensions and functional assessment with coronary computed tomographic angiography as compared to echocardiography using American Society of Echocardiography guidelines

    PubMed Central

    Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C

    2014-01-01

    Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706

  13. Intraoperative Fluorescence Cerebral Angiography by Laser Surgical Microscopy: Comparison With Xenon Microscopy and Simultaneous Observation of Cerebral Blood Flow and Surrounding Structures.

    PubMed

    Ito, Yuhei; Suzuki, Kyouichi; Ichikawa, Tsuyoshi; Watanabe, Yoichi; Sato, Taku; Sakuma, Jun; Saito, Kiyoshi

    2018-06-12

    Laser surgical microscopes should enable uniform illumination of the operative field, and require less luminous energy compared with existing xenon surgical microscopes. To examine the utility of laser illumination in fluorescence cerebral angiography. Fluorescein sodium (fluorescein) was used as a fluorescent dye. We first compared the clarity of cerebral blood flow images collected by fluorescence angiography between the laser illumination and xenon illumination methods. We then assessed use of the laser illuminator for simultaneous observation of blood flow and surrounding structures during fluorescence angiography. Furthermore, the study was designed to evaluate usefulness of the thus determined excitation light in clinical cases. Fluorescence angiography using blue light laser for excitation provided higher clarity and contrast blood flow images compared with using blue light generated from a xenon lamp. Further, illumination with excitation light consisting of a combination of 3 types of laser (higher level of blue light, no green light, and lower level of red light) enabled both blood flow and surrounding structures to be observed through the microscope directly by the surgeon. Laser-illuminated fluorescence angiography provides high clarity and contrast images of cerebral blood flow. Further, a laser providing strong blue light and weak red light for excitation light enables simultaneous visual observation of fluorescent blood flow and surrounding structures by the surgeon using a surgical microscope. Overall, these data suggest that laser surgical microscopes are useful for both ordinary operative manipulations and fluorescence angiography.

  14. Acute choroidal ischemia associated with toxoplasmic retinochoroiditis.

    PubMed

    Khairallah, Moncef; Yahia, Salim Ben; Zaouali, Sonia; Jenzeri, Salah; Attia, Sonia; Messaoud, Riadh

    2007-09-01

    To describe eight patients with active toxoplasmic retinochoroiditis (RC) who had features suggestive of acute choroidal ischemia. A retrospective review of the clinical records of 23 consecutive patients with acute toxoplasmic RC was performed. All patients underwent detailed ophthalmic examination at presentation and throughout follow-up, including dilated biomicroscopic fundus examination, fundus photography, fluorescein angiography, and indocyanine green (ICG) angiography. Of 23 patients, 8 (34.8%) had a large area of retinal whitening surrounding a small focus of RC. Fluorescein as well as ICG angiography showed a well demarcated geographic area of early choroidal hypofluorescence that extended beyond the clinical borders of the white retinal lesion, particularly by ICG angiography. Associated findings for these 8 patients included old retinochoroidal scars (7 [87.5%]), serous retinal detachment (3 [37.5%]), retinal hemorrhages (1 [12.5%]), and multiple satellite dark dots by ICG angiography (6 [75%]). Seven of eight patients were treated using a combination of antitoxoplasmic drugs and corticosteroids. All findings seen at the acute stage resolved in 2 weeks to 6 weeks. A small atrophic retinochoroidal scar replaced the active toxoplasmic lesion and was surrounded with mild or moderate retinal pigment epithelium changes that were associated with decreased final visual acuity in 2 patients (25%). Patients with toxoplasmic RC may develop features suggestive of choroidal ischemia that can result in a transient or permanent decrease in vision. Choroidal ischemia can only be suspected clinically, and fluorescein angiography and ICG angiography are required to establish the definitive diagnosis.

  15. An automatic fuzzy-based multi-temporal brain digital subtraction angiography image fusion algorithm using curvelet transform and content selection strategy.

    PubMed

    Momeni, Saba; Pourghassem, Hossein

    2014-08-01

    Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.

  16. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    PubMed

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand administration of IV contrast agent and 30 (65%; 10.2 ± 4.2 years; range 4-18 years) had mechanical administration of IV contrast agent. All 46 abdominal CT angiography studies were of diagnostic quality based on qualitative evaluation (all ≥3). All abdominal CT angiography studies from both groups showed diagnostic quality of contrast enhancement (>150 HU) at both the celiac axis and the inferior mesenteric artery (IMA) levels. The contrast enhancement of the abdominal aorta was not significantly different between the IV contrast administration methods at either the celiac axis level (360 ± 158 vs. 353 ± 116, P = 0.24) or the IMA level (340 ± 140 vs. 351 ± 90, P = 0.27), adjusting for age. Diagnostic-quality abdominal CT angiography can be achieved using hand administration of IV contrast agent in infants and young children (≤5 years).

  17. Naringin improves random skin flap survival in rats

    PubMed Central

    Cheng, Liang; Chen, Tingxiang; Tu, Qiming; Li, Hang; Feng, Zhenghua; Li, Zhijie; Lin, Dingsheng

    2017-01-01

    Background Random-pattern flap transfer is commonly used to treat soft-tissue defects. However, flap necrosis remains a serious problem. Naringin accelerates angiogenesis by activating the expression of vascular endothelial growth factor (VEGF). In the present study, we investigated whether naringin improves the survival of random skin flaps. Results Compared with controls, the naringin-treated groups exhibited significantly larger mean areas of flap survival, significantly increased SOD activity and VEGF expression, and significantly reduced MDA level. Hematoxylin and eosin (HE) staining revealed that naringin promoted angiogenesis and inhibited inflammation. Materials and Methods “McFarlane flap” models were established in 90 male Sprague-Dawley (SD) rats divided into three groups: a 40 mg/kg control group (0.5 % sodium carboxymethylcellulose), a 40 mg/kg naringin-treated group, and an 80 mg/kg naringin-treated group. The extent of necrosis was measured 7 days later, and tissue samples were subjected to histological analysis. Angiogenesis was evaluated via lead oxide–gelatin angiography, immunohistochemistry, and laser Doppler imaging. Inflammation was evaluated by measurement of serum TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) levels. Oxidative stress was assessed by measuring superoxide dismutase (SOD) activity and the malondialdehyde (MDA) level. Conclusion Naringin improved random skin flap survival. PMID:29212216

  18. Indocyanine green angiographic evidence of choroiditis in scleroderma.

    PubMed

    Abdellatief, Amro; Balasubramaniam, Saranya C; Grube, Thomas J; Gonzalez Santiago, Tania M; Osborn, Thomas G; Pulido, Jose S

    2015-01-01

    The purpose of this case report was to demonstrate evidence of indocyanine green angiography leakage consistent with choroiditis in a patient with scleroderma. In this case report, the patient underwent a variety of tests and examinations, including systemic evaluation, full ocular examination, skin biopsy, indocyanine green, and fluorescein angiography testing. A 52-year-old man had blurred vision centrally in both eyes. Vision was 20/25 and 20/20. Posterior examination showed cotton-wool spots in both eyes. The patient met European League against Rheumatism (EULAR) criteria for scleroderma. Fluorescein angiography confirmed the presence of leakage from the retinal vessels. More importantly, indocyanine green angiography revealed choroidal vessel leakage in both eyes. This provided evidence of choroiditis before vessel obliteration. Previous studies have shown evidence of choriocapillaris obliteration. Choroidal vessel leakage, however, has not been reported in patients with scleroderma. The results of this case demonstrate the usefulness of indocyanine green angiography in detecting the presence of choroiditis in scleroderma.

  19. Intracranial vascular stenosis and occlusion: Diagnostic accuracy of three-dimensional, fourier transform, time-of-flight MR angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korogi, Yukunori; Takahashi, Mutsumasa; Mabuchi, Nobuhisa

    1994-10-01

    To assess the accuracy of three-dimensional, Fourier transform, time-of-flight magnetic resonance (MR) angiography in the detection of intracranial steno-occlusive diseases. One hundred thirty-one patients (62 male and 69 female patients, aged 6-77 years [mean, 53 years 8 months]) underwent MR and conventional angiography for evaluation of possible intracranial vascular disease. A total of 502 arteries were assessed. Eight projections and a collapsed image postprocessed by means of a maximum-intensity projection algorithm were reviewed by five observers in a blinded manner, with conventional angiography as the standard. A total of 32 steno-occlusive lesions were available for review. Receiver operating characteristic analysismore » from the pooled data revealed overall sensitivities of 85% and 88% and specificities of 96% and 97% for the internal carotid artery and the middle cerebral artery, respectively. MR angiography is useful as the primary diagnostic tool for evaluating suspected intracranial steno-occlusive disease. 22 refs., 7 figs., 5 tabs.« less

  20. Renal arteriography

    MedlinePlus

    Renal angiogram; Angiography - kidney; Renal angiography; Renal artery stenosis - arteriography ... an artery by a blood clot Renal artery stenosis Renal cell cancer Angiomyolipomas (noncancerous tumors of the ...

  1. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

    PubMed

    Miller, Julie M; Dewey, Marc; Vavere, Andrea L; Rochitte, Carlos E; Niinuma, Hiroyuki; Arbab-Zadeh, Armin; Paul, Narinder; Hoe, John; de Roos, Albert; Yoshioka, Kunihiro; Lemos, Pedro A; Bush, David E; Lardo, Albert C; Texter, John; Brinker, Jeffery; Cox, Christopher; Clouse, Melvin E; Lima, João A C

    2009-04-01

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

  2. MR angiography of the renal artery: comparison of breath-hold two-dimensional phase-contrast cine technique with the phased-array coil and breath-hold two-dimensional time-of-flight technique with the body coil.

    PubMed

    Masui, T; Takehara, Y; Igarashi, T; Ichijo, K; Takahashi, M; Kaneko, M; Nozaki, A

    1997-07-01

    Breath-hold 2D phase-contrast (PC) cine MR angiography with a phased-array coil and 2D time-of-flight (TOF) MR angiography were performed in the renal arteries and their findings were compared. Breath-hold 2D thin slice PC and TOF MR angiography were performed in 10 normal volunteers for renal arteries. A PC technique with k-space segmentation was utilized with the phased-array coil. A PC technique provided visualization of the renal artery more distally than a TOF technique (4.8 +/- 0.5 cm vs. 3.7 +/- 0.8 cm). With cardiac triggering, distal renal arteries were well demonstrated in PC MR angiography. On PC images, up- or downward movements of the mid to distal renal arteries with aortic pulsatility were recognized. The quality of the images was better with the PC than with the TOF technique (3.4 vs. 2.7). The mid to distal portions of the renal arteries translationally move with aortic pulsatility. To consistently visualize and evaluate them on MR angiography, cardiac triggering might be required to reduce the effects of pulsatile motions of the renal artery in the use of a phased-array coil.

  3. Socioeconomic characteristics of patients undergoing ambulatory diagnostic cerebral angiography in four US States.

    PubMed

    Bekelis, K; Missios, S; Eskey, C; Labropoulos, N

    2014-02-01

    Several groups have demonstrated the safety of ambulatory cerebral angiography, with no patients experiencing complications related to early discharge. Although this practice appears to be safe, the socioeconomic characteristics factoring in the selection of the patients have not been investigated. We performed a retrospective cohort study involving 45,226 patients undergoing outpatient and 159,046 undergoing inpatient cerebral angiography, who were registered in the State Ambulatory Surgery Databases (SASD) and State Inpatient Databases (SID) respectively for 4 US States (New York, California, Florida, North Carolina). In a multivariate analysis of diagnostic cerebral angiography, Caucasian race (OR 1.36, 95% CI, 1.31, 1.42) and male gender (OR 1.36, 95% CI, 1.31, 1.41), were significantly associated with outpatient procedures. Higher Charlson Comorbidity Index (CCI) (OR 0.60, 95% CI, 0.54, 0.67), high income (OR 0.70, 95% CI, 0.67, 0.73), high volume hospitals (OR 0.69, 95% CI, 0.66, 0.73), and coverage by Medicare/Medicaid (OR 0.96, 95% CI, 0.92, 0.99) were associated with a decreased chance of outpatient procedures. Institutional charges were significantly less for outpatient cerebral angiography. The median charge for inpatient diagnostic cerebral angiography was $26,968 as compared to $16,151 in the outpatient setting (P < 0.0001, Student's t-test). Access to ambulatory diagnostic cerebral angiography appears to be more common for patients with private insurance and less comorbidities, in the setting of lower volume hospitals. Further investigation is needed in the direction of mapping these disparities in resource utilization.

  4. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    PubMed Central

    Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y.; Alley, Marcus T.; Lustig, Michael; Pauly, John M.; Vasanawala, Shreyas S.

    2015-01-01

    Background Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. Objective To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast enhanced MR angiography method for depicting abdominal arterial anatomy in young children. Materials and methods With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast enhanced MR angiography studies. An radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Results Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9–5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Conclusion Free-breathing spatiotemporally accelerated 3-D time-resolved contrast enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries for pediatric contrast enhanced MR angiography. PMID:26040509

  5. Disparities in acute in-hospital cardiovascular care for Aboriginal and non-Aboriginal South Australians.

    PubMed

    Tavella, Rosanna; McBride, Katharine; Keech, Wendy; Kelly, Janet; Rischbieth, Amanda; Zeitz, Christopher; Beltrame, John F; Tideman, Philip A; Brown, Alex

    2016-09-05

    To assess differences in the rates of angiography and subsequent revascularisation for Aboriginal and non-Aboriginal South Australians who presented with an acute coronary syndrome (ACS); to explore the reasons for any observed differences. Analysis of administrative data with logistic regression modelling to assess the relationship between Aboriginal status and the decision to undertake diagnostic angiography. A detailed medical record review of Aboriginal admissions was subsequently undertaken. Emergency ACS admissions to SA cardiac catheterisation hospitals, 2007-2012. 13 701 admissions of patients with an ACS, including 274 Aboriginal patients (2.1%). Rates of coronary angiography and revascularisation; documentation of justification for non-invasive management. After adjustment for age, comorbidities and remoteness, Aboriginal patients presenting with an ACS were significantly less likely than non-Aboriginal patients to undergo angiography (odds ratio [OR], 0.4; 95% CI, 0.3-0.5; P < 0.001). There was no significant difference in the rates of revascularisation for Aboriginal and non-Aboriginal patients who had undergone angiography. Reasons for Aboriginal patients not undergoing angiography included symptoms being deemed non-cardiac (16%), non-invasive test performed (8%), and discharge against medical advice (11%); the reasons were unclear for 36% of Aboriginal patients. After controlling for age and other factors, the rate of coronary angiography was lower among Aboriginal patients with an ACS in SA. The reasons for this disparity are complex, including patient-related factors and their preferences, as well as the appropriateness of the intervention. Improved consideration of the hospital experience of Aboriginal patients must be a priority for reducing health care disparities.

  6. Aortic angiography

    MedlinePlus

    Angiography - aorta; Aortography; Abdominal aorta angiogram; Aortic arteriogram; Aneurysm - aortic arteriogram ... this needle. The catheter is moved into the aorta. The doctor can see live images of the ...

  7. Three-dimensional magnetic resonance angiography of vascular lesions in children.

    PubMed

    Katayama, H; Shimizu, T; Tanaka, Y; Narabayashi, I; Tamai, H

    2000-01-01

    We applied three-dimensional (3D) magnetic resonance (MR) angiography to vascular lesions in children and evaluated the clinical usefulness of this technique. Ten patients, whose ages ranged from 1 month to 16 years, underwent 3D MR angiography for 12 vascular lesions, including lesions in seven pulmonary arteries, two thoracic aortae, a pair of renal arteries, and one iliac artery. Three-dimensional MR angiography was performed with body-or pelvic-phased array coils on a 1.5-T scanner using fast spoiled gradient echo sequence. Data were acquired with the following parameters: TE, 1.9 ms; TR, 10.1 ms; flip angle, 20-60 degrees ; 1 or 2 NEX; field of view, 24-48 x 18-40 cm; matrix, 256 or 512 x 128 or 256; slice thickness, 1.2-7.5 mm; and 12, 28, or 60 partitions. Vascular imaging was enhanced with 20% gadolinium-diethylenetriaminepentaacetic acid. The examination was performed under breath-holding in six patients and with shallow breathing in four patients. In a comparative study with other noninvasive methods, 3D MR angiography was superior in seven of nine cases to other noninvasive examinations and in two cases, all methods evaluated the lesions. Furthermore, six cases were compared with conventional angiography. In five of the six cases, both methods depicted the lesions similarly, and in one case, MR angiography was more effective. A quantitative comparison of vascular diameter in the MR image was made with that in the conventional angiographic image. The correlation between them was excellent: y = 1.145x-2.090 (r = 0.987; P < 0.0001), where x is the diameter in the conventional angiographic images, y is the diameter in the MR images, and r is the correlation coefficient. In conclusion, 3D MR angiography is useful for depicting peripheral vascular lesions in children.

  8. Angiography reveals novel features of the retinal vasculature in healthy and diabetic mice.

    PubMed

    McLenachan, Samuel; Magno, Aaron Len; Ramos, David; Catita, Joana; McMenamin, Paul G; Chen, Fred Kuanfu; Rakoczy, Elizabeth Piroska; Ruberte, Jesus

    2015-09-01

    The mouse retina is a commonly used animal model for the study of pathogenesis and treatment of blinding retinal vascular diseases such as diabetic retinopathy. In this study, we aimed to characterize normal and pathological variations in vascular anatomy in the mouse retina using fluorescein angiography visualized with scanning laser ophthalmoscopy and optical coherence tomography (SLO-OCT). We examined eyes from C57BL/6J wild type mice as well as the Ins2(Akita) and Akimba mouse models of diabetic retinopathy using the Heidelberg Retinal Angiography (HRA) and OCT system. Angiography was performed on three focal planes to examine distinct vascular layers. For comparison with angiographic data, ex vivo analyses, including Indian ink angiography, histology and 3D confocal scanning laser microscopy were performed in parallel. All layers of the mouse retinal vasculature could be readily visualized during fluorescein angiography by SLO-OCT. Blood vessel density was increased in the deep vascular plexus (DVP) compared with the superficial vascular plexus (SVP). Arteriolar and venular typologies were established and structural differences were observed between venular types. Unexpectedly, the hyaloid artery was found to persist in 15% of C57BL/6 mice, forming anastomoses with peripheral retinal capillaries. Fluorescein leakage was easily detected in Akimba retinae by angiography, but was not observed in Ins2(Akita) mice. Blood vessel density was increased in the DVP of 6 month old Ins2(Akita) mice, while the SVP displayed reduced branching in precapillary arterioles. In summary, we present the first comprehensive characterization of the mouse retinal vasculature by SLO-OCT fluorescein angiography. Using this clinical imaging technique, we report previously unrecognized variations in C57BL/6J vascular anatomy and novel features of vascular retinopathy in the Ins2(Akita) mouse model of diabetes. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  9. N-Acetylcysteine added to volume expansion with sodium bicarbonate does not further prevent contrast-induced nephropathy: results from the cardiac angiography in renally impaired patients study.

    PubMed

    Staniloae, Cezar S; Doucet, Serge; Sharma, Samin K; Katholi, Richard E; Mody, Kanika R; Coppola, John T; Solomon, Richard

    2009-06-01

    We reviewed data from the multicenter CARE (Cardiac Angiography in Renally Impaired Patients) study to see if benefit could be shown for N-acetylcysteine (NAC) in patients undergoing cardiac angiography who all received intravenous bicarbonate fluid expansion. Four hundred fourteen patients with moderate-to-severe chronic kidney disease were randomized to receive intra-arterial administration of iopamidol-370 or iodixanol-320. All patients were prehydrated with isotonic sodium bicarbonate solution. Each site chose whether or not to administer NAC 1,200 mg twice daily to all patients. Serum creatinine (SCr) levels and estimated glomerular filtration rate were assessed at baseline and 2-5 days after receiving contrast. The primary outcome was a postdose SCr increase 0.5 mg/dL (44.2 mumol/L) over baseline. Secondary outcomes were a postdose SCr increase 25% and the mean peak change in SCr. The NAC group received significantly less hydration (892 +/- 236 mL vs. 1016 +/- 328 mL; P < 0.001) and more contrast volume (146 +/- 74 mL vs. 127 +/- 71 mL; P = 0.009) compared with no-NAC group. SCr increases 0.5 mg/dL occurred in 4.2% (7 of 168 patients) in NAC group and 6.5% (16 of 246 patients) in no-NAC group (P = 0.38); rates of SCr increases 25% were 11.9% and 10.6%, respectively (P = 0.75); mean post-SCr increases were 0.07 mg/dL in NAC group versus 0.11 mg/dL in no-NAC group (P = 0.14). In conclusion, addition of NAC to fluid expansion with sodium bicarbonate failed to reduce the rate of contrast-induced nephropathy (CIN) after the intra-arterial administration of iopamidol or iodixanol to high-risk patients with chronic kidney disease.

  10. Associations Between Collateral Status and Thrombus Characteristics and Their Impact in Anterior Circulation Stroke.

    PubMed

    Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M

    2018-02-01

    Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with moderate and high collateral scores. URL: http://www.trialregister.nl. Unique identifier: NTR1804 and URL: http://www.controlled-trials.com Unique identifier: ISRCTN10888758. © 2018 The Authors.

  11. Novel Fluorescein Angiography-Based Computer-Aided Algorithm for Assessment of Retinal Vessel Permeability

    PubMed Central

    Chassidim, Yoash; Parmet, Yisrael; Tomkins, Oren; Knyazer, Boris; Friedman, Alon; Levy, Jaime

    2013-01-01

    Purpose To present a novel method for quantitative assessment of retinal vessel permeability using a fluorescein angiography-based computer algorithm. Methods Twenty-one subjects (13 with diabetic retinopathy, 8 healthy volunteers) underwent fluorescein angiography (FA). Image pre-processing included removal of non-retinal and noisy images and registration to achieve spatial and temporal pixel-based analysis. Permeability was assessed for each pixel by computing intensity kinetics normalized to arterial values. A linear curve was fitted and the slope value was assigned, color-coded and displayed. The initial FA studies and the computed permeability maps were interpreted in a masked and randomized manner by three experienced ophthalmologists for statistical validation of diagnosis accuracy and efficacy. Results Permeability maps were successfully generated for all subjects. For healthy volunteers permeability values showed a normal distribution with a comparable range between subjects. Based on the mean cumulative histogram for the healthy population a threshold (99.5%) for pathological permeability was determined. Clear differences were found between patients and healthy subjects in the number and spatial distribution of pixels with pathological vascular leakage. The computed maps improved the discrimination between patients and healthy subjects, achieved sensitivity and specificity of 0.974 and 0.833 respectively, and significantly improved the consensus among raters for the localization of pathological regions. Conclusion The new algorithm allows quantification of retinal vessel permeability and provides objective, more sensitive and accurate evaluation than the present subjective clinical diagnosis. Future studies with a larger patients’ cohort and different retinal pathologies are awaited to further validate this new approach and its role in diagnosis and treatment follow-up. Successful evaluation of vasculature permeability may be used for the early diagnosis of brain microvascular pathology and potentially predict associated neurological sequelae. Finally, the algorithm could be implemented for intraoperative evaluation of micovascular integrity in other organs or during animal experiments. PMID:23626701

  12. Atherosclerosis and Liver Function Tests in Coronary Angiography Patients.

    PubMed

    Doganer, Y C; Rohrer, J E; Aydogan, U; Agerter, D C; Cayci, T; Barcin, C

    2015-09-01

    Elevated aminotransferase levels indicating liver function, even in the normal range, have attracted great concern as potential novel markers of cardiovascular risk assessment. We hypothesized the possibility that liver function test variations in the normal range might be meaningfully associated to coronary artery disease (CAD). Eighty-eight patients were randomly selected from those who underwent coronary angiography from June 2010 to June 2011 after applying to the outpatient cardiology clinic in Gulhane Military Medical Academy. According to the results of angiographies, patients were classified into three groups as normal, non-critical (< 50% involvement in coronaries), and critical (≥ 50% involvement in coronaries). In addition to angiographic intervention, measurements of serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) concentrations, albumin and the other serum parameters were performed in all patients. The patient groups of CAD were balanced (28 critical cases, 30 non-critical cases and 30 normal cases). Mean age was 51.93 ± 9.3 (range 32-65) years and 19.3 per cent (n = 17) were females. Multiple linear regression analysis of all three liver function tests explained a significant portion of the variance, but adjusted r-squares were small (AST = 0.174, ALT = 0.242, albumin = 0.124). Albumin was significantly higher for patients with critical CAD than for patients with no CAD (beta = 3.205, p = 0.002). Non-critical CAD was not significantly different from no CAD for any of the dependent variables. Mean AST was significantly higher for patients taking aspirin (beta = 0.218, p = 0.049), as was mean ALT (beta = 0.264, p = 0.015). Alanine aminotransferase and AST may not be associated with angiographically determined coronary atherosclerosis. Albumin may be more sensitive to demonstrate the burden of atherosclerosis. These results indicate that the association between the liver function tests and coronary atherosclerosis may be more complex than generally appreciated.

  13. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    PubMed Central

    Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. Conclusions This design of the novel ePTFE transcatheter pulmonary valve is safe and effective to deploy in sheep by hybrid approach, and the early valvular functionality is good. PMID:24926892

  14. The Role of N-Acetylcysteine in the Prevention of Contrast-Induced Nephrotoxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandhu, Caron; Belli, Anna-Maria; Oliveira, David B.

    2006-06-15

    Purpose. To determine the role of prophylactic N-acetylcysteine in the prevention of contrast-induced nephrotoxicity. Methods. One hundred and sixteen patients undergoing noncoronary angiography, with or without pre-existing renal impairment, were randomly assigned to receive prophylactic oral N-acetylcysteine or no treatment. Serum creatinine (sCr) was measured prior to angiography and 48 hr after the procedure. Urine samples were collected before and after the examination for measurement of malondialdehyde (MDA) concentration. Contrast-induced nephrotoxicity (CIN) was defined as a rise in serum creatinine of 0.5 mg/dl (44 mmol/l) at 48 hr. Results. Complete data were available on 106 patients, 53 of whom hadmore » received N-acetylcysteine. There were no significant differences between the two groups in baseline characteristics, type of angiogram, or volume and concentration of contrast used. Three patients (2.8%), all of whom had received N-acetylcysteine, developed CIN. In the N-acetylcysteine group, the mean serum creatinine in patients with renal impairment was 151.0 {+-} 44.2 {mu}mol/l prior to the procedure and 155.6 {+-} 48.6 {mu}mol/l (p = 0.49) after the procedure. Respective values for those without renal impairment were 79.6 {+-} 15.1 {mu}mol/l and 81.2 {+-} 20.0 {mu}mol/l (p = 0.65). In the group that had not received N-acetylcysteine, the mean serum creatinine levels before and after the procedure were 150.0 {+-} 58.1 and 141.4 {+-} 48.0 {mu}mol/l (p = 0.17) in patients with renal impairment and 79.7 {+-} 14.2 and 81.4 {+-} 15.4 {mu}mol/l (p = 0.34) in those without renal impairment. In both groups, no significant change in urinary MDA concentration was observed. Conclusion. There is no benefit to the prophylactic administration of N-acetylcysteine in patients undergoing peripheral angiography using current contrast media.« less

  15. Contrast induced-acute kidney injury following peripheral angiography with carbon dioxide versus iodinated contrast media: A meta-analysis and systematic review of current literature.

    PubMed

    Ghumman, Saad S; Weinerman, Jonathan; Khan, Aazib; Cheema, Mubeen S; Garcia, Marlene; Levin, Daniel; Suri, Rajeev; Prasad, Anand

    2017-09-01

    We conducted a meta-analysis to compare the incidence of acute kidney injury (AKI) with carbon dioxide (CO 2 ) versus iodinated contrast media (ICM). Contrast induced-acute kidney injury (CI-AKI) is a known complication following endovascular procedures with ICM. CO 2 has been employed as an alternative imaging medium as it is nontoxic to the kidneys. Search of indexed databases was performed and 1,732 references were retrieved. Eight studies (7 observational, 1 Randomized Controlled Trial) formed the meta-analysis. Primary outcome was AKI. Fixed effect model was used when possible in addition to analysis of publication bias. In this meta-analysis, 677 patients underwent 754 peripheral angiographic procedures. Compared with ICM, CO 2 was associated with a decreased incidence of AKI (4.3% vs. 11.1%; OR 0.465, 95% CI: 0.218-0.992; P = 0.048). Subgroup analysis of four studies that included granular data for patients with chronic kidney disease (CKD) did not demonstrate a decreased incidence of AKI with CO 2 (4.1% vs. 10.0%; OR 0.449, 95% CI: 0.165-1.221, P = 0.117). Patients undergoing CO 2 angiography experienced a higher number of nonrenal events including limb/abdominal pain (11 vs. 0; P = 0.001) and nausea/vomiting (9 vs. 1; P = 0.006). In comparison to ICM, CO 2 use is associated with a modestly reduced rate of AKI with more frequent adverse nonrenal events. In studies that use CO 2 as the primary imaging agent, the average incidence of AKI remained high at 6.2%-supporting the concept that factors other than renal toxicity from ICM may contribute to renal impairment following peripheral angiography. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. F-18 Choline PET angiography of the pelvic arteries: evaluation of image quality and comparison with contrast-enhanced CT.

    PubMed

    Freesmeyer, Martin; Drescher, Robert

    2015-01-01

    The purpose was to show the feasibility of F-18 choline positron emission tomography (PET) angiography for the evaluation of abdominal and iliac arteries. Thirty-five patients were examined and image quality was scored. Findings were correlated with contrast-enhanced computed tomography. Image quality was best in the aorta and common iliac arteries (100% and 93% of vessels). Negative predictive values of PET angiography were excellent (100%), and positive predictive values were impaired by disease overestimation. PET angiography is technically feasible and of good image quality in large arteries. In selected cases, it may become an alternative to established angiographic methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Inpatient Coronary Angiography and Revascularisation following Non-ST-Elevation Acute Coronary Syndrome in Patients with Renal Impairment: A Cohort Study Using the Myocardial Ischaemia National Audit Project

    PubMed Central

    Shaw, Catriona; Nitsch, Dorothea; Steenkamp, Retha; Junghans, Cornelia; Shah, Sapna; O’Donoghue, Donal; Fogarty, Damian; Weston, Clive; Sharpe, Claire C.

    2014-01-01

    Background International guidelines support an early invasive management strategy (including early coronary angiography and revascularisation) for non-ST-elevation acute coronary syndrome (NSTE-ACS) in patients with renal impairment. However, evidence from outside the UK suggests that this approach is underutilised. We aimed to describe practice within the NHS, and to determine whether the severity of renal dysfunction influenced the provision of angiography and modified the association between early revascularisation and survival. Methods We performed a cohort study, using multivariable logistic regression and propensity score analyses, of data from the Myocardial Ischaemia National Audit Project for patients presenting with NSTE-ACS to English or Welsh hospitals between 2008 and 2010. Findings Of 35 881 patients diagnosed with NSTE-ACS, eGFR of <60 ml/minute/1.73 m2 was present in 15 680 (43.7%). There was a stepwise decline in the odds of undergoing inpatient angiography with worsening renal dysfunction. Compared with an eGFR>90 ml/minute/1.73 m2, patients with an eGFR between 45–59 ml/minute/1.73 m2 were 33% less likely to undergo angiography (adjusted OR 0.67, 95% CI 0.55–0.81); those with an eGFR<30/minute/1.73 m2 had a 64% reduction in odds of undergoing angiography (adjusted OR 0.36, 95%CI 0.29–0.43). Of 16 646 patients who had inpatient coronary angiography, 58.5% underwent inpatient revascularisation. After adjusting for co-variables, inpatient revascularisation was associated with approximately a 30% reduction in death within 1 year compared with those managed medically after coronary angiography (adjusted OR 0.66, 95%CI 0.57–0.77), with no evidence of modification by renal function (p interaction = 0.744). Interpretation Early revascularisation may offer a similar survival benefit in patients with and without renal dysfunction, yet renal impairment is an important determinant of the provision of coronary angiography following NSTE-ACS. A randomised controlled trial is needed to evaluate the efficacy of an early invasive approach in patients with severe renal dysfunction to ensure that all patients who may benefit are offered this treatment option. PMID:24937680

  18. Improved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound

    PubMed Central

    Podlesek, Dino; Meyer, Tobias; Morgenstern, Ute; Schackert, Gabriele; Kirsch, Matthias

    2015-01-01

    Introduction Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. Methods We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment. Results Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient). Conclusions Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative rotational digital subtraction angiography. PMID:25803318

  19. Direct costs and cost-effectiveness of dual-source computed tomography and invasive coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease.

    PubMed

    Dorenkamp, Marc; Bonaventura, Klaus; Sohns, Christian; Becker, Christoph R; Leber, Alexander W

    2012-03-01

    The study aims to determine the direct costs and comparative cost-effectiveness of latest-generation dual-source computed tomography (DSCT) and invasive coronary angiography for diagnosing coronary artery disease (CAD) in patients suspected of having this disease. The study was based on a previously elaborated cohort with an intermediate pretest likelihood for CAD and on complementary clinical data. Cost calculations were based on a detailed analysis of direct costs, and generally accepted accounting principles were applied. Based on Bayes' theorem, a mathematical model was used to compare the cost-effectiveness of both diagnostic approaches. Total costs included direct costs, induced costs and costs of complications. Effectiveness was defined as the ability of a diagnostic test to accurately identify a patient with CAD. Direct costs amounted to €98.60 for DSCT and to €317.75 for invasive coronary angiography. Analysis of model calculations indicated that cost-effectiveness grew hyperbolically with increasing prevalence of CAD. Given the prevalence of CAD in the study cohort (24%), DSCT was found to be more cost-effective than invasive coronary angiography (€970 vs €1354 for one patient correctly diagnosed as having CAD). At a disease prevalence of 49%, DSCT and invasive angiography were equally effective with costs of €633. Above a threshold value of disease prevalence of 55%, proceeding directly to invasive coronary angiography was more cost-effective than DSCT. With proper patient selection and consideration of disease prevalence, DSCT coronary angiography is cost-effective for diagnosing CAD in patients with an intermediate pretest likelihood for it. However, the range of eligible patients may be smaller than previously reported.

  20. Utilization of cardiac computed tomography angiography and outpatient invasive coronary angiography in Ontario, Canada.

    PubMed

    Roifman, Idan; Rezai, Mohammad R; Wijeysundera, Harindra C; Chow, Benjamin J W; Wright, Graham A; Tu, Jack V

    2015-01-01

    Cardiac computed tomography angiography (coronary CTA) has emerged as a non-invasive method of diagnosing coronary artery disease. The extent of utilization and uptake of this technology since initiation of its funding by the government of Ontario is unknown. The aim of our study was to examine coronary CTA utilization and the rates of elective invasive coronary angiography and revascularization before and after funding initiation. We studied all coronary CTAs performed on adults in Ontario after initiation of funding. We also used an interrupted time series analysis to compare the average monthly rates of invasive angiography and revascularization before and after initiation of funding. There was an initial steep increase in age-and sex-standardized rates of coronary CTA from 5.0 to 11.4/100,000 over the first two quarters after funding initiation. Afterwards, there was a gradual increase in utilization from 11.4 to 17.1/100,000 over two subsequent calendar years. There was a significant reduction in both the mean monthly outpatient invasive coronary angiography (from 20.7 to 19.9 per 100,000 (p = 0.0004)) and revascularization (from 4.9 to 4.4 per 100,000 (p < 0.0001)) rates in the three years following introduction of the coronary CTA billing code as compared to the three prior to its introduction. Since the introduction of coronary CTA funding in Ontario, there has been a steady and controlled increase in its utilization. The increasing use of coronary CTA was associated with a reduction in both the rates of invasive angiography and revascularization. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  1. Comparing treatment outcomes of fractional flow reserve-guided and angiography-guided percutaneous coronary intervention in patients with multi-vessel coronary artery diseases: a systematic review and meta-analysis.

    PubMed

    Xiu, Jiancheng; Chen, Gangbin; Zheng, Hua; Wang, Yuegang; Chen, Haibin; Liu, Xuewei; Wu, Juefei; Bin, Jianping

    2016-02-01

    Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is used to assess the need for angioplasty in vessels with intermediate blockages. The treatment outcomes of FFR-guided vs. conventional angiography-guided PCI were evaluated in patients with multi-vessel coronary artery disease (CAD). Prospective and retrospective studies comparing FFR-guided vs. angiography-guided PCI in patients with multi-vessel CAD were identified from medical databases by two independent reviewers using the terms "percutaneous coronary intervention, fractional flow reserve, angiography, coronary heart disease, major adverse cardiac events (MACE) and myocardial infarction". The primary outcome was the number of stents placed, and the secondary outcomes were procedure time, mortality, myocardial infarction (MI) and MACE rates. Seven studies (three retrospective and four prospective), which included 49,517 patients, were included in this review. A total of 4,755 patients underwent FFR, while 44,697 received angiography-guided PCI. The mean patient age ranged from 58 to 71.7 years. The average number of stents used in FFR patients ranged from 0.3-1.9, and in angiography-guided PCI patients ranged from 0.7-2.7. Analysis indicated there was a greater number of stents placed in the angiography-guided group compared with the FFR group (pooled difference in means: -0.64, 95% confidence interval [CI]: -0.81 to -0.47, P < 0.001). There were no differences in the secondary outcomes between the two groups. Both procedures produce similar clinical outcomes, but the fewer number of stents used with FFR may have clinical as was as cost implications.

  2. Indocyanine Green Angiography Use in Breast Reconstruction: A National Analysis of Outcomes and Cost in 110,320 Patients.

    PubMed

    Chattha, Anmol; Bucknor, Alexandra; Chen, Austin D; Lee, Bernard T; Lin, Samuel J

    2018-04-01

    Indocyanine green angiography has gained popularity in breast reconstruction for its ability to assess mastectomy skin and tissue flap viability. The authors aim to analyze trends and outcomes associated with indocyanine green angiography use in breast reconstruction. Using 2012 to 2014 data from the Healthcare Cost and Utilization Project National Inpatient Sample, Agency for Healthcare Research and Quality, the authors identified breast reconstructions performed with or without indocyanine green angiography use. Trends over time were assessed using the Cochran-Armitage test. Outcomes were assessed using logistic regression and generalized linear modeling. Over the study period, 110,320 patients underwent breast reconstruction: 107,005 (97.0 percent) without and 3315 (3.0 percent) with indocyanine green angiography use. Usage increased over time: 750 patients (1.9 percent) in 2012, increasing to 1275 patients (3.7 percent) in 2013 (p < 0.001). Smokers (p = 0.018), hypertensive patients (p = 0.046), obese patients (p < 0.001), and those with a higher comorbidity index (p < 0.001) were more likely to undergo indocyanine green angiography. Autologous reconstruction was more frequently combined with its use compared with tissue expander reconstruction (4.5 percent versus 2.1 percent; p < 0.001). There was a significant increase in the odds of débridement associated with its use (OR, 1.404; p < 0.001; 95 percent CI, 1.201 to 1.640). Indocyanine green angiography use in breast reconstruction has increased in recent years and is associated with higher débridement rates. These rates may indicate changing trends for clinicians when deciding whether to débride tissue during breast reconstruction. Therapeutic, III.

  3. Indocyanine green fluorescence angiography for quantitative evaluation of in situ parathyroid gland perfusion and function after total thyroidectomy.

    PubMed

    Lang, Brian Hung-Hin; Wong, Carlos K H; Hung, Hing Tsun; Wong, Kai Pun; Mak, Ka Lun; Au, Kin Bun

    2017-01-01

    Because the fluorescent light intensity on an indocyanine green fluorescence angiography reflects the blood perfusion within a focused area, the fluorescent light intensity in the remaining in situ parathyroid glands may predict postoperative hypocalcemia risk after total thyroidectomy. Seventy patients underwent intraoperative indocyanine green fluorescence angiography after total thyroidectomy. Any parathyroid glands with a vascular pedicle was left in situ while any parathyroid glands without pedicle or inadvertently removed was autotransplanted. After total thyroidectomy, an intravenous 2.5 mg indocyanine green fluorescence angiography was given and real-time fluorescent images of the thyroid bed were recorded using the SPY imaging system (Novadaq, Ontario, Canada). The fluorescent light intensity of each indocyanine green fluorescence angiography as well as the average and greatest fluorescent light intensity in each patient were calculated. Postoperative hypocalcemia was defined as adjusted calcium <2.00 mmol/L within 24 hours. The fluorescent light intensity between discolored and normal-looking indocyanine green fluorescence angiographies was similar (P = .479). No patients with a greatest fluorescent light intensity >150% developed postoperative hypocalcemia while 9 (81.8%) patients with a greatest fluorescent light intensity ≤150% did. Similarly, no patients with an average fluorescent light intensity >109% developed PH while 9 (30%) with an average fluorescent light intensity ≤109% did. The greatest fluorescent light intensity was more predictive than day-0 postoperative hypocalcemia (P = .027) and % PTH drop day-0 to 1 (P < .001). Indocyanine green fluorescence angiography is a promising operative adjunct in determining residual parathyroid glands function and predicting postoperative hypocalcemia risk after total thyroidectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. SPECTRAL DOMAIN VERSUS SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY OF THE RETINAL CAPILLARY PLEXUSES IN SICKLE CELL MACULOPATHY.

    PubMed

    Jung, Jesse J; Chen, Michael H; Frambach, Caroline R; Rofagha, Soraya; Lee, Scott S

    2018-01-01

    To compare the spectral domain and swept source optical coherence tomography angiography findings in two cases of sickle cell maculopathy. A 53-year-old man and a 24-year-old man both with sickle cell disease (hemoglobin SS) presented with no visual complaints; Humphrey visual field testing demonstrated asymptomatic paracentral scotomas that extended nasally in the involved eyes. Clinical examination and multimodal imaging including spectral domain and swept source optical coherence tomography, and spectral domain optical coherence tomography angiography and swept source optical coherence tomography angiography (Carl Zeiss Meditec Inc, Dublin, CA) were performed. Fundus examination of both patients revealed subtle thinning of the macula. En-face swept source optical coherence tomography confirmed the extent of the thinning correlating with the functional paracentral scotomas on Humphrey visual field. Swept source optical coherence tomography B-scan revealed multiple confluent areas of inner nuclear thinning and significant temporal retinal atrophy. En-face 6 × 6-mm spectral domain optical coherence tomography angiography of the macula demonstrated greater loss of the deep capillary plexus compared with the superficial capillary plexus. Swept source optical coherence tomography angiography 12 × 12-mm imaging captured the same macular findings and loss of both plexuses temporally outside the macula. In these two cases of sickle cell maculopathy, deep capillary plexus ischemia is more extensive within the macula, whereas both the superficial capillary plexus and deep capillary plexus are involved outside the macula likely due to the greater oxygen demands and watershed nature of these areas. Swept source optical coherence tomography angiography clearly demonstrates the angiographic extent of the disease correlating with the Humphrey visual field scotomas and confluent areas of inner nuclear atrophy.

  5. Improved visualization of intracranial vessels with intraoperative coregistration of rotational digital subtraction angiography and intraoperative 3D ultrasound.

    PubMed

    Podlesek, Dino; Meyer, Tobias; Morgenstern, Ute; Schackert, Gabriele; Kirsch, Matthias

    2015-01-01

    Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment. Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient). Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative rotational digital subtraction angiography.

  6. Cracking the perfusion code?: Laser-assisted Indocyanine Green angiography and combined laser Doppler spectrophotometry for intraoperative evaluation of tissue perfusion in autologous breast reconstruction with DIEP or ms-TRAM flaps.

    PubMed

    Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P

    2016-10-01

    The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.

    PubMed

    Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L

    2017-10-01

    Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.

  8. Predictors of Active Extravasation and Complications after Conventional Angiography for Acute Intraabdominal Bleeding.

    PubMed

    Haber, Zachary M; Charles, Hearns W; Erinjeri, Joseph P; Deipolyi, Amy R

    2017-04-18

    Conventional angiography is used to evaluate and treat possible sources of intraabdominal bleeding, though it may cause complications such as contrast-induced nephropathy (CIN). The study's purpose was to identify factors predicting active extravasation and complications during angiography for acute intraabdominal bleeding. All conventional angiograms for acute bleeding (January 2013-June 2015) were reviewed retrospectively, including 75 angiograms for intraabdominal bleeding in 70 patients. Demographics, comorbidities, vital signs, complications within one month, and change in hematocrit (ΔHct) and fluids and blood products administered over the 24 h prior to angiography were recorded. Of 75 exams, 20 (27%) demonstrated extravasation. ΔHct was the only independent predictor of extravasation ( p = 0.017), with larger ΔHct (-17%) in patients with versus those without extravasation (-1%) ( p = 0.01). CIN was the most common complication, occurring in 10 of 66 angiograms (15%). Glomerular filtration rate (GFR) was the only independent predictor ( p = 0.03); 67% of patients with GFR < 30, 29% of patients with GFR 30-60, and 8% of patients with GFR > 60 developed CIN. For patients with intraabdominal bleeding, greater ΔHct decrease over 24 h before angiography predicts active extravasation. Pre-existing renal impairment predicts CIN. Patients with large hematocrit declines should be triaged for rapid angiography, though benefits can be weighed with the risk of renal impairment.

  9. Statin use prior to angiography for the prevention of contrast-induced acute kidney injury: a meta-analysis of 19 randomised trials.

    PubMed

    Thompson, Keith; Razi, Rabia; Lee, Ming Sum; Shen, Albert; Stone, Gregg W; Hiremath, Swapnil; Mehran, Roxana; Brar, Somjot S

    2016-06-20

    A systematic review and a meta-analysis were performed to define better the role of statin use prior to angiography in preventing contrast-induced acute kidney injury (CI-AKI). MEDLINE, Embase, Cochrane Library, references from review articles, and conference proceedings were searched, with no language restriction, for randomised controlled trials (RCT) evaluating the use of statin therapy prior to angiography for the prevention of CI-AKI. Nineteen RCTs including 7,161 patients were identified. The pooled analysis demonstrated a significant reduction in the incidence of CI-AKI in patients treated with statin prior to invasive angiography when compared with control (RR 0.52; 95% CI: 0.40-0.67). Patients with chronic kidney disease stage 3 or worse were largely underrepresented in these trials, and statin therapy did not significantly reduce the risk of CI-AKI in the three studies which enrolled a patient population with a mean eGFR of <60 ml/min (RR 0.54; 95% CI: 0.2-1.42). This meta-analysis suggests a potential benefit for statin use prior to angiography to reduce the incidence of CI-AKI. Additional research is needed to define better the benefits of statin therapy prior to angiography to prevent CI-AKI, especially in high-risk patients with chronic kidney disease who were largely underrepresented in the available trials.

  10. Predictors of Active Extravasation and Complications after Conventional Angiography for Acute Intraabdominal Bleeding

    PubMed Central

    Haber, Zachary M.; Charles, Hearns W.; Erinjeri, Joseph P.; Deipolyi, Amy R.

    2017-01-01

    Conventional angiography is used to evaluate and treat possible sources of intraabdominal bleeding, though it may cause complications such as contrast-induced nephropathy (CIN). The study’s purpose was to identify factors predicting active extravasation and complications during angiography for acute intraabdominal bleeding. All conventional angiograms for acute bleeding (January 2013–June 2015) were reviewed retrospectively, including 75 angiograms for intraabdominal bleeding in 70 patients. Demographics, comorbidities, vital signs, complications within one month, and change in hematocrit (ΔHct) and fluids and blood products administered over the 24 h prior to angiography were recorded. Of 75 exams, 20 (27%) demonstrated extravasation. ΔHct was the only independent predictor of extravasation (p = 0.017), with larger ΔHct (−17%) in patients with versus those without extravasation (–1%) (p = 0.01). CIN was the most common complication, occurring in 10 of 66 angiograms (15%). Glomerular filtration rate (GFR) was the only independent predictor (p = 0.03); 67% of patients with GFR < 30, 29% of patients with GFR 30–60, and 8% of patients with GFR > 60 developed CIN. For patients with intraabdominal bleeding, greater ΔHct decrease over 24 h before angiography predicts active extravasation. Pre-existing renal impairment predicts CIN. Patients with large hematocrit declines should be triaged for rapid angiography, though benefits can be weighed with the risk of renal impairment. PMID:28420210

  11. Angiographic lesion size associated with LOC387715 A69S genotype in subfoveal polypoidal choroidal vasculopathy.

    PubMed

    Sakurada, Yoichi; Kubota, Takeo; Imasawa, Mitsuhiro; Tsumura, Toyoaki; Mabuchi, Fumihiko; Tanabe, Naohiko; Iijima, Hiroyuki

    2009-01-01

    To investigate whether the LOC387715/ARMS2 variants are associated with an angiographic phenotype, including lesion size and composition, in subfoveal polypoidal choroidal vasculopathy. Ninety-two subjects with symptomatic subfoveal polypoidal choroidal vasculopathy, whose visual acuity was from 0.1 to 0.5 on the Landolt chart, were genotyped for the LOC387715 polymorphism (rs10490924) using denaturing high-performance chromatography. The angiographic phenotype, including lesion composition and size, was evaluated by evaluators who were masked for the genotype. Lesion size was assessed by the greatest linear dimension based on fluorescein or indocyanine green angiography. Although there was no statistically significant difference in lesion size on indocyanine green angiography (P = 0.36, Kruskal-Wallis test) and in lesion composition (P = 0.59, chi-square test) among the 3 genotypes, there was a statistically significant difference in lesion size on fluorescein angiography (P = 0.0022, Kruskal-Wallis test). The LOC387715 A69S genotype is not associated with lesion composition or size on indocyanine green angiography but with lesion size on fluorescein angiography in patients with subfoveal polypoidal choroidal vasculopathy. Because fluorescein angiography findings represent secondary exudative changes, including subretinal hemorrhages and retinal pigment epithelial detachment, the results in the present study likely indicate that the T allele at the LOC387715 gene is associated with the exudative activity of polypoidal lesions.

  12. Prevalence of Hepatitis C Virus Seropositivity and Its Impact on Coronary Artery Disease among Egyptian Patients Referred for Coronary Angiography

    PubMed Central

    Salam, Ragab Abd El; Nabil, Baher; Saber, Marawan; AbdelWahab, Hany A.

    2016-01-01

    Background. We tested the prevalence and impact of HCV seropositivity among Egyptian patients referred for coronary angiography. Subjects and Methods. This cross-sectional study was conducted in Zagazig University hospitals including 509 patients scheduled for elective coronary angiography between June 2013 and June 2014. By taking full history on admission, laboratory workup including HCV Ab, echocardiography study, and coronary angiography, we calculated the mean number of coronary artery lesions and the mean number of affected coronary artery vessels for all patients. The severity of the coronary lesions was estimated using the Gensini score. Results. HCV seropositive patients referred for coronary angiography were about 30.3% (which is greater than the prevalence of HCV seropositivity among general population in Egypt), patients proved to have CAD who are HCV antibody positive had more severe coronary lesions than in seronegative one (p < 0.05), and patients proved to have CAD who are HCV antibody positive had comparable prevalence of cardiovascular risk factors as seronegative patients except for diabetes and hypertension which are more prevalent in seronegative patients (p < 0.05). Conclusion. Prevalence of HCV antibody positive patients referred for coronary angiography was about 30.3%, and CAD patients who are HCV antibody positive had more severe coronary lesions and less prevalence of diabetes and hypertension than HCV antibody negative. PMID:27882261

  13. DETECTION OF TREATMENT-NAIVE CHOROIDAL NEOVASCULARIZATION IN AGE-RELATED MACULAR DEGENERATION BY SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Ahmed, Daniel; Stattin, Martin; Graf, Alexandra; Forster, Julia; Glittenberg, Carl; Krebs, Ilse; Ansari-Shahrezaei, Siamak

    2017-09-04

    To compare the detection rate of choroidal neovascularization (CNV) in treatment-naive neovascular age-related macular degeneration by swept source optical coherence tomography angiography (SS-OCTA, Topcon's DRI Triton) working at 1,050 nm wavelength versus fluorescence angiography. Cross-sectional analysis of 156 eyes (107 neovascular age-related macular degeneration and 49 dry AMD) in 98 patients, previously diagnosed by multimodal imaging using fluorescein (FA) and indocyanine green angiography (Heidelberg's Spectralis) in a tertiary retina center, evaluated by SS-OCTA 4.5 mm × 4.5 mm and 6 mm × 6 mm macular cubes. Main outcome measures were sensitivity and specificity of SS-OCTA in AMD. Potential factors influencing CNV detection rate were analyzed. Swept source optical coherence tomography angiography detected CNV in 81 of 107 eyes, resulting in a sensitivity of 75.7%. In 49 eyes with dry AMD, no CNV could be identified (specificity 100%). A statistical significance was calculated for nondetection of treatment-naive CNV by SS-OCTA in pigment epithelial detachment over 400 μm (P = 0.0238). Topcon's SS-OCTA was not able to detect all CNV lesions. Large pigment epithelial detachments were associated with signal loss. Fluorescence angiography still remains the gold standard, but the tested SS-OCTA device can be considered as a feasible additional diagnostic tool in AMD.

  14. New stroboscopic light source and technique for intraoperative retinal fluorescein angiography during penetrating keratoplasty

    NASA Astrophysics Data System (ADS)

    Krueger, Ronald R.; Morales, Ronald B.; Chong, Lawrence P.; Smith, Ronald E.

    1994-06-01

    We report the development of a new stroboscopic light source system and technique for performing intraoperative fluorescein angiography during penetrating keratoplasty for aphakic or pseudophakic bullous keratopathy. A controllable pulse xenon light source system with a fiber optic endoilluminator probe is used to perform high-quality intraoperative fluorescein angiography during penetrating keratoplasty in pigmented rabbits and human subjects. Following corneal trephination and extraction of the intraocular lens, a temporary Cobo keratoprosthesis is secured while a 20-gauge endoilluminator is inserted into the vitreous cavity through a limbal incision. The endoilluminator is advanced to a retinal illumination area of approximately 3 DD and 10% fluorescein is injected intravenously. A microscope camera coupled to a 50:50 beamsplitter photographs the passage of fluorescein dye while the surgeon maintains an unaltered view through the operating microscope. Angiograms through a keratoprosthesis show excellent contrast and resolution, comparable to standard fluorescein angiography. Fine peripapillary vessels are seen reproducibly and with great detail in the rabbits. All the phases of retinal angiography can be seen, including arteriolar constriction and capillary nonperfusion in one of four human subjects examined. High quality intraoperative fluorescein angiography can be performed in patients undergoing penetrating keratoplasty for aphakic/ pseudophakic bullous keratopathy. With this technology, preexisting retinal disorders such as cystoid macular edema might be identified in the perioperative setting allowing for important management decisions to be made intraoperatively.

  15. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  16. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  17. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  18. 21 CFR 522.563 - Diatrizoate meglumine and diatrizoate sodium injection.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., peripheral arteriography, and venography; selective coronary arteriography; cerebral angiography... intraventricular puncture. For cerebral angiography rapid injection of 3 to 10 milliliters via carotid artery. For...

  19. MR Angiography (MRA)

    MedlinePlus

    ... resonance angiography (MRA), a powerful magnetic field, radio frequency waves and a computer produce detailed images of ... test. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ...

  20. Effect of Ticagrelor Plus Aspirin, Ticagrelor Alone, or Aspirin Alone on Saphenous Vein Graft Patency 1 Year After Coronary Artery Bypass Grafting: A Randomized Clinical Trial.

    PubMed

    Zhao, Qiang; Zhu, Yunpeng; Xu, Zhiyun; Cheng, Zhaoyun; Mei, Ju; Chen, Xin; Wang, Xiaowei

    2018-04-24

    The effect of ticagrelor with or without aspirin on saphenous vein graft patency in patients undergoing coronary artery bypass grafting (CABG) is unknown. To compare the effect of ticagrelor + aspirin or ticagrelor alone vs aspirin alone on saphenous vein graft patency 1 year after CABG. Randomized, multicenter, open-label, clinical trial among 6 tertiary hospitals in China. Eligible patients were aged 18 to 80 years with indications for elective CABG. Patients requiring urgent revascularization, concomitant cardiac surgery, dual antiplatelet or vitamin K antagonist therapy post-CABG, and who were at risk of serious bleeding were excluded. From July 2014 until November 2015, 1256 patients were identified and 500 were enrolled. Follow-up was completed in January 2017. Patients were randomized (1:1:1) to start ticagrelor (90 mg twice daily) + aspirin (100 mg once daily) (n = 168), ticagrelor (90 mg twice daily) (n = 166), or aspirin (100 mg once daily) (n = 166) within 24 hours post-CABG. Neither patients nor treating physicians were blinded to allocation. Primary outcome was saphenous vein graft patency 1 year after CABG (FitzGibbon grade A) adjudicated independently by a committee blinded to allocation. Saphenous vein graft patency was assessed by multislice computed tomographic angiography or coronary angiography. Among 500 randomized patients (mean age, 63.6 years; women, 91 [18.2%]), 461 (92.2%) completed the trial. Saphenous vein graft patency rates 1 year post-CABG were 88.7% (432 of 487 vein grafts) with ticagrelor + aspirin; 82.8% (404 of 488 vein grafts) with ticagrelor alone; and 76.5% (371 of 485 vein grafts) with aspirin alone. The difference between ticagrelor + aspirin vs aspirin alone was statistically significant (12.2% [95% CI, 5.2% to 19.2%]; P < .001), whereas the difference between ticagrelor alone vs aspirin alone was not statistically significant (6.3% [95% CI, -1.1% to 13.7%]; P = .10). Five major bleeding episodes occurred during 1 year of follow-up (3 with ticagrelor + aspirin; 2 with ticagrelor alone). Among patients undergoing elective CABG with saphenous vein grafting, ticagrelor + aspirin significantly increased graft patency after 1 year vs aspirin alone; there was no significant difference between ticagrelor alone and aspirin alone. Further research with more patients is needed to assess comparative bleeding risks. clinicaltrials.gov Identifier: NCT02201771.

  1. Transient cortical blindness after coronary angiography.

    PubMed Central

    Parry, R; Rees, J R; Wilde, P

    1993-01-01

    Transient visual loss lasting three days developed after transfemoral coronary angiography in a 62 year old man. Computed tomography (CT) showed bilateral leakage of contrast medium into the occipital cortex. A repeat CT scan after his sight recovered showed clearance of contrast with no underlying infarction. A breakdown of the blood-brain barrier with direct neurotoxicity of the contrast media seemed to be the cause of these neurological changes after coronary angiography which apparently have not been reported before. Images PMID:8280526

  2. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay.

    PubMed

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  3. Imaging in the evaluation of renovascular disease

    PubMed Central

    Roebuck, Derek J.; McLaren, Clare A.; Marks, Stephen D.

    2009-01-01

    Renovascular disease (RVD) is an important cause of hypertension in children, as it often is amenable to potentially curative treatment. Imaging aimed at finding RVD therefore needs to have high sensitivity so as not to miss important findings. Digital subtraction angiography is the gold standard investigation. Doppler ultrasonography, computed tomography (CT) angiography and magnetic resonance (MR) angiography can all be helpful, but none has, at present, high enough sensitivity to rule out RVD in a child with a suggestion of that diagnosis. PMID:19856000

  4. Rash, fever, and chills after intravenous fluorescein angiography.

    PubMed

    Johnson, R N; McDonald, H R; Schatz, H

    1998-12-01

    To report a previously unreported complication associated with intravenous injection of fluorescein dye. Case report. A 75-year-old man developed a unique complication after intravenous injection of fluorescein dye for angiography. Two hours after receiving an intravenous injection of fluorescein for angiography, the patient developed a fever, rash, and chills. Admission to a hospital and careful systemic evaluation determined that this reaction was a noninfectious allergic response to intravenous fluorescein dye injection. A delayed allergic response to intravenous fluorescein dye injection can occur.

  5. Multiphase contrast medium injection for optimization of computed tomographic coronary angiography.

    PubMed

    Budoff, Matthew Jay; Shinbane, Jerold S; Child, Janis; Carson, Sivi; Chau, Alex; Liu, Stephen H; Mao, SongShou

    2006-02-01

    Electron beam angiography is a minimally invasive imaging technique. Adequate vascular opacification throughout the study remains a critical issue for image quality. We hypothesized that vascular image opacification and uniformity of vascular enhancement between slices can be improved using multiphase contrast medium injection protocols. We enrolled 244 consecutive patients who were randomized to three different injection protocols: single-phase contrast medium injection (Group 1), dual-phase contrast medium injection with each phase at a different injection rate (Group 2), and a three-phase injection with two phases of contrast medium injection followed by a saline injection phase (Group 3). Parameters measured were aortic opacification based on Hounsfield units and uniformity of aortic enhancement at predetermined slices (locations from top [level 1] to base [level 60]). In Group 1, contrast opacification differed across seven predetermined locations (scan levels: 1st versus 60th, P < .05), demonstrating significant nonuniformity. In Group 2, there was more uniform vascular enhancement, with no significant differences between the first 50 slices (P > .05). In Group 3, there was greater uniformity of vascular enhancement and higher mean Hounsfield units value across all 60 images, from the aortic root to the base of the heart (P < .05). The three-phase injection protocol improved vascular opacification at the base of the heart, as well as uniformity of arterial enhancement throughout the study.

  6. Design and rationale for the Influenza vaccination After Myocardial Infarction (IAMI) trial. A registry-based randomized clinical trial.

    PubMed

    Fröbert, Ole; Götberg, Matthias; Angerås, Oskar; Jonasson, Lena; Erlinge, David; Engstrøm, Thomas; Persson, Jonas; Jensen, Svend E; Omerovic, Elmir; James, Stefan K; Lagerqvist, Bo; Nilsson, Johan; Kåregren, Amra; Moer, Rasmus; Yang, Cao; Agus, David B; Erglis, Andrejs; Jensen, Lisette O; Jakobsen, Lars; Christiansen, Evald H; Pernow, John

    2017-07-01

    Registry studies and case-control studies have demonstrated that the risk of acute myocardial infarction (AMI) is increased following influenza infection. Small randomized trials, underpowered for clinical end points, indicate that future cardiovascular events can be reduced following influenza vaccination in patients with established cardiovascular disease. Influenza vaccination is recommended by international guidelines for patients with cardiovascular disease, but uptake is varying and vaccination is rarely prioritized during hospitalization for AMI. The Influenza vaccination After Myocardial Infarction (IAMI) trial is a double-blind, multicenter, prospective, registry-based, randomized, placebo-controlled, clinical trial. A total of 4,400 patients with ST-segment elevation myocardial infarction (STEMI) or non-STEMI undergoing coronary angiography will randomly be assigned either to in-hospital influenza vaccination or to placebo. Baseline information is collected from national heart disease registries, and follow-up will be performed using both registries and a structured telephone interview. The primary end point is a composite of time to all-cause death, a new AMI, or stent thrombosis at 1 year. The IAMI trial is the largest randomized trial to date to evaluate the effect of in-hospital influenza vaccination on death and cardiovascular outcomes in patients with STEMI or non-STEMI. The trial is expected to provide highly relevant clinical data on the efficacy of influenza vaccine as secondary prevention after AMI. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  7. Carotid Angioplasty and Stenting

    MedlinePlus

    ... and of the blood flow to the brain. Magnetic resonance angiography (MRA) or computerized tomography angiography (CTA). ... vessels by using either radiofrequency waves in a magnetic field or by using X-rays with contrast ...

  8. Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction

    PubMed Central

    Shen, Junlin; Du, Xiangying; Guo, Daode; Cao, Lizhen; Gao, Yan; Yang, Qi; Li, Pengyu; Liu, Jiabin; Li, Kuncheng

    2013-01-01

    Objectives To evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). Materials and Methods We performed a prospective randomized study evaluating 338 patients undergoing CCTA with prospective ECG-triggering. Patients were randomly assigned to fixed tube current with filtered back projection (Group 1, n = 113), noise-based tube current with filtered back projection (Group 2, n = 109) or with iterative reconstruction (Group 3, n = 116). Tube voltage was fixed at 120 kV. Qualitative image quality was rated on a 5-point scale (1 = impaired, to 5 = excellent, with 3–5 defined as diagnostic). Image noise and signal intensity were measured; signal-to-noise ratio was calculated; radiation dose parameters were recorded. Statistical analyses included one-way analysis of variance, chi-square test, Kruskal-Wallis test and multivariable linear regression. Results Image noise was maintained at the target value of 35HU with small interquartile range for Group 2 (35.00–35.03HU) and Group 3 (34.99–35.02HU), while from 28.73 to 37.87HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 20% and 51% reduction in effective dose for Group 2 (2.9 mSv) and Group 3 (1.8 mSv) were achieved compared with Group 1 (3.7 mSv). After adjustment for scan characteristics, iterative reconstruction was associated with 26% reduction in effective dose. Conclusion Noise-based tube current reduction method with iterative reconstruction maintains image noise precisely at the desired level and achieves consistent image quality. Meanwhile, effective dose can be reduced by more than 50%. PMID:23741444

  9. The spot sign and tranexamic acid on preventing ICH growth--AUStralasia Trial (STOP-AUST): protocol of a phase II randomized, placebo-controlled, double-blind, multicenter trial.

    PubMed

    Meretoja, Atte; Churilov, Leonid; Campbell, Bruce C V; Aviv, Richard I; Yassi, Nawaf; Barras, Christen; Mitchell, Peter; Yan, Bernard; Nandurkar, Harshal; Bladin, Christopher; Wijeratne, Tissa; Spratt, Neil J; Jannes, Jim; Sturm, Jonathan; Rupasinghe, Jayantha; Zavala, Jorge; Lee, Andrew; Kleinig, Timothy; Markus, Romesh; Delcourt, Candice; Mahant, Neil; Parsons, Mark W; Levi, Christopher; Anderson, Craig S; Donnan, Geoffrey A; Davis, Stephen M

    2014-06-01

    No evidence-based acute therapies exist for intracerebral hemorrhage. Intracerebral hemorrhage growth is an important determinant of patient outcome. Tranexamic acid is known to reduce hemorrhage in other conditions. The study aims to test the hypothesis that intracerebral hemorrhage patients selected with computed tomography angiography contrast extravasation 'spot sign' will have lower rates of hematoma growth when treated with intravenous tranexamic acid within 4.5-hours of stroke onset compared with placebo. The Spot sign and Tranexamic acid On Preventing ICH growth--AUStralasia Trial is a multicenter, prospective, 1:1 randomized, double-blind, placebo-controlled, investigator-initiated, academic Phase II trial. Intracerebral hemorrhage patients fulfilling clinical criteria (e.g. Glasgow Coma Scale >7, intracerebral hemorrhage volume <70 ml, no identified secondary cause of intracerebral hemorrhage, no thrombotic events within the previous 12 months, no planned surgery) and demonstrating contrast extravasation on computed tomography angiography will receive either intravenous tranexamic acid 1 g 10-min bolus followed by 1 g eight-hour infusion or placebo. A second computed tomography will be performed at 24 ± 3 hours to evaluate intracerebral hemorrhage growth and patients followed up for three-months. The primary outcome measure is presence of intracerebral hemorrhage growth by 24 ± 3 hours, defined as either >33% or >6 ml increase from baseline, and will be adjusted for baseline intracerebral hemorrhage volume. Secondary outcome measures include growth as a continuous measure, thromboembolic events, and the three-month modified Rankin Scale score. This is the first trial to evaluate the efficacy of tranexamic acid in intracerebral hemorrhage patients selected based on an imaging biomarker of high likelihood of hematoma growth. The trial is registered as NCT01702636. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.

  10. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    PubMed

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. A multicentre, randomized, double-blind placebo-controlled trial evaluating rosiglitazone for the prevention of atherosclerosis progression after coronary artery bypass graft surgery in patients with type 2 diabetes. Design and rationale of the VeIn-Coronary aTherOsclerosis and Rosiglitazone after bypass surgerY (VICTORY) trial

    PubMed Central

    Bertrand, Olivier F; Poirier, Paul; Rodés-Cabau, Josep; Rinfret, Stéphane; Title, Lawrence; Dzavik, Vladimir; Natarajan, Madhu; Angel, Juan; Batalla, Nuria; Alméras, Natalie; Costerousse, Olivier; De Larochellière, Robert; Roy, Louis; Després, Jean-Pierre

    2009-01-01

    BACKGROUND: The number of patients with coronary artery disease and type 2 diabetes will increase dramatically over the next decade. Diabetes has been related to accelerated atherosclerosis and many patients with diabetes will require coronary artery bypass graft (CABG) surgery utilizing saphenous vein grafts. After CABG, accelerated atherosclerosis in saphenous vein grafts leads to graft failure in approximately 50% of cases over a 10-year period. Rosiglitazone, a peroxisome proliferator-activated receptor-gamma agonist, has been shown to improve multiple metabolic parameters in patients with type 2 diabetes. However, its role in the prevention of atherosclerosis progression is uncertain. STUDY DESIGN: VeIn-Coronary aTherOsclerosis and Rosiglitazone after bypass surgerY (VICTORY) is a cardiometabolic trial in which patients with type 2 diabetes, one to 10 years after CABG, will be randomly assigned to receive rosiglitazone (up to 8 mg/day) or a placebo after qualifying angiography and intravascular ultrasound of a segment of one vein graft with or without a native anastomosed coronary artery. A comprehensive set of athero-thrombo-inflammatory markers will be serially assessed during the 12-month follow-up period. Body fat distribution and body composition will be assessed by computed tomography and dual energy x-ray absorptiometry, respectively, at baseline, six months and 12 months follow-up. For atherosclerosis progression evaluation, repeat angiography and intravascular ultrasound will be performed after 12 months follow-up. The primary end point of the study will be the change in atherosclerotic plaque volume in a 40 mm or longer segment of one vein graft. CONCLUSIONS: The VICTORY trial is the first cardiometabolic study to evaluate the antiatherosclerotic and metabolic effects of rosiglitazone in post-CABG patients with type 2 diabetes. PMID:19746240

  12. Is carbon dioxide a safe and good alternative for diatrizoate meglumine as a contrast in digital subtraction angiography?

    PubMed

    Hegde, U N; Khanapet, M S; Rajapurkar, M M; Gang, S D; Gohel, K D; Rane, G; Parikh, P; Patil, D; Desai, T; Patil, P; Kelawala, N

    2009-01-01

    Contrast-induced nephropathy is well-known sequelae of iodinated contrast (diatrizoate meglumine). Carbon dioxide (CO(2)) can be used as an alternative contrast agent. The aim of this study was to compare the renal injury and the quality of images of aortogram using iodinated contrast versus CO(2) using digital subtraction angiography (DSA). This prospective randomized study was done in 29 healthy dogs using DSA aortogram. Dogs were randomly assigned to receive iodinated contrast or CO(2). 6-F pigtail catheter was introduced via femoral artery approach to perform aortogram under general anesthesia. Serum creatinine (S.Cr.) and urinary enzymes, namely: N-acetyl D-glucosaminidase (NAG), alanine aminopeptidase (AAP), and gamma glutamyl transferase (GGT), were measured before and 48 hours after aortogram. There was no change in S.Cr. in both the groups. Significantly more enzymuria was seen following iodinated contrast than CO(2). Enzymuria pre and postaortogram following the iodinated contrast was GGT: 14.9 +/- 5.92 vs. 26.2 +/- 15.1 (P = 0.001), NAG: 1.63 +/- 0.90 vs. 3.6 +/- 2.14 (P = 0.0001), and AAP: 1.51 +/- 0.75 vs. 3.38 2.41 (P = 0.001), and in the CO(2) group was GGT: 15.5 +/- 4.9 vs. 21.1 +/- 9.04 (P = 0.02), NAG: 2.12 +/- 1.06 vs. 3.82 3.27 (P = 0.08), and AAP: 1.28 +/- 0.76 vs. 2.51 +/- 1.72 (P = 0.03). More than 50% increase over the preprocedural value was significantly less following CO(2). Images obtained with iodinated contrast were superior to those with CO(2,) however, the quality of image with CO(2) was adequate for delineation of the renal artery and major branches. Both iodinated contrast and CO(2) cause significant enzymuria. More severe enzymuria (>50% increase) was seen significantly less with the use of CO(2). Quality of images is better with iodinated contrast.

  13. Safety of coronary CT angiography and functional testing for stable chest pain in the PROMISE trial: A randomized comparison of test complications, incidental findings, and radiation dose.

    PubMed

    Lu, Michael T; Douglas, Pamela S; Udelson, James E; Adami, Elizabeth; Ghoshhajra, Brian B; Picard, Michael H; Roberts, Rhonda; Lee, Kerry L; Einstein, Andrew J; Mark, Daniel B; Velazquez, Eric J; Carter, William; Ridner, Michael; Al-Khalidi, Hussein R; Hoffmann, Udo

    Coronary computed tomography angiography (CTA) and functional testing strategies for stable chest pain yield similar outcomes; one aspect that may guide test choice is safety. We compared test safety (test complications, incidental findings, and effective radiation dose) between CTA and functional testing as-tested in PROMISE (PROspective Multicenter Imaging Study for Evaluation of Chest Pain). In the subgroup whose physicians intended nuclear stress over other functional tests if randomized to the functional arm, we compared radiation dose of CTA versus nuclear stress and identified characteristics associated with dose. Of 9470 patients, none had major and <1% had minor complications (CTA: 0.8% [37/4633] vs. functional: 0.6% [27/4837]). CTA identified more incidental findings (11.6% [539/4633] vs. 0.7% [34/4837], p < 0.001), most commonly pulmonary nodules (9.4%, 437/4633). CTA had similar 90-day cumulative radiation dose to functional testing. However, in the subgroup whose physicians intended nuclear stress (CTA 3147; nuclear 3203), CTA had lower median index test (8.8 vs. 12.6 mSv, p < 0.001) and 90-day cumulative (11.6 vs. 13.1 mSv, p < 0.001) dose, independent of patient characteristics. The lowest nuclear doses employed 1-day Tc-99m protocols (12.2 mSv). The lowest CTA doses were at sites performing ≥500 CTAs/year (6.9 mSv) and with advanced (latest available) CT scanners (5.5 mSv). Complications were negligibly rare for both CTA and functional testing. CTA detects more incidental findings. Compared to nuclear stress testing, CTA's lower radiation dose, independent of patient characteristics, makes it an attractive test choice. Radiation dose varies with imaging protocol, indicating opportunities to further reduce dose. (ClinicalTrials.gov number, NCT01174550). Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  14. Fondaparinux with UnfracTionated heparin dUring Revascularization in Acute coronary syndromes (FUTURA/OASIS 8): a randomized trial of intravenous unfractionated heparin during percutaneous coronary intervention in patients with non-ST-segment elevation acute coronary syndromes initially treated with fondaparinux.

    PubMed

    Steg, Philippe Gabriel; Mehta, Shamir; Jolly, Sanjit; Xavier, Denis; Rupprecht, Hans-Juergen; Lopez-Sendon, Jose Luis; Chrolavicius, Susan; Rao, Sunil V; Granger, Christopher B; Pogue, Janice; Laing, Shiona; Yusuf, Salim

    2010-12-01

    There is uncertainty regarding the optimal adjunctive unfractionated heparin (UFH) regimen for percutaneous coronary intervention (PCI) in patients with non-ST-segment elevation acute coronary syndrome (NSTE-ACS) treated with fondaparinux. The aim of this study is to evaluate the safety of 2 dose regimens of adjunctive intravenous UFH during PCI in high-risk patients with NSTE-ACS initially treated with fondaparinux and referred for early coronary angiography. This is an international prospective cohort study of approximately 4,000 high-risk patients presenting to hospital with unstable angina or non-ST-segment elevation myocardial infarction, treated with fondaparinux as initial medical therapy, and referred for early coronary angiography with a view to revascularization. Within this cohort, 2,000 patients undergoing PCI will be eligible for enrollment into a double-blind international randomized parallel-group trial evaluating standard activated clotting time (ACT)-guided doses of intravenous UFH versus a non-ACT-guided weight-adjusted low dose. The standard regimen uses an 85-U/kg bolus of UFH if there is no platelet glycoprotein IIb/IIIa (GpIIb-IIIa) inhibitor or 60 U/kg if GpIIb-IIIa inhibitor use is planned, with additional bolus guided by blinded ACT measurements. The low-dose regimen uses a 50 U/kg UFH bolus, irrespective of planned GpIIb-IIIa use. The primary outcome is the composite of peri-PCI major bleeding, minor bleeding, or major vascular access site complications. The assessment of net clinical benefit is a key secondary outcome: it addresses the composite of peri-PCI major bleeding with death, myocardial infarction, or target vessel revascularization at day 30. FUTURA/OASIS 8 will help define the optimal UFH regimen as adjunct to PCI in high-risk NSTE-ACS patients treated with fondaparinux. Copyright © 2010 Mosby, Inc. All rights reserved.

  15. A novel high nitrogen nickel-free coronary stents system: evaluation in a porcine model.

    PubMed

    Zhang, Bin; Chen, Ming; Zheng, Bo; Wang, Xin Gang; Wang, Xi Ting; Fan, Yuan Yuan; Huo, Yong

    2014-04-01

    To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Three types of stents were randomly implanted in different coronary arteries of the same pig: 316 L stainless steel BMS (316 L-BMS) (n=12), novel high nitrogen nickel-free stents Grid A (NF-A-BMS) (n=12) and novel high nitrogen nickel-free stents Grid B (NF-B-BMS) (n=12). In total, eighteen animals underwent successful random placement of 36 oversized stents in the coronary arteries. Coronary angiography was performed after 36 d of stents implantation. Nine animals were respectively sacrificed after 14 d and 36 d for histomorphologic analysis. Quantitative coronary angiography (QCA) showed similar luminal loss (LL) in the three groups: (0.21 ± 0.17) mm for 316 L-BMS, (0.16 ± 0.12) mm for NF-A-BMS, (0.24 ± 0.15) mm for NF-B-BMS (P>0.05). Histomorphomeric analysis after 15 d and 36 d revealed that there was also no significant difference among the three groups in neointimal area (NA) with similar injury scores respectively. High magnification histomorphologic examination showed similar inflammation scores in the three groups, but NF-A-BMS group had poorer endothelialization scores compared with NF-B-BMS group, 2.00 ± 0.63 vs. 2.83 ± 0.41 (P=0.015) at 15 d, which also could be proved by the scanning electron microscope. However, the difference could not been observed at 36 d. The novel NF-BMS showed similar safety as 316 L-BMS during the short-term study. NF-B-BMS had better endothelialization than NF-A-BMS and this may owe to the specific strut units. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  16. 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram-triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral Scan.

    PubMed

    Lin, Lu; Wang, Yi-Ning; Kong, Ling-Yan; Jin, Zheng-Yu; Lu, Guang-Ming; Zhang, Zhao-Qi; Cao, Jian; Li, Shuo; Song, Lan; Wang, Zhi-Wei; Zhou, Kang; Wang, Ming

    2013-01-01

    Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequential scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrillation referred for a second-generation 128-slice DSCT coronary angiography were included in the prospective study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG-triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel-lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each patient were compared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean HR (t=1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by reader1 and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by reader1 and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27±0.19 vs. 1.25±0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively ECG-gated spiral scan, prospectively ECG-triggered sequential DSCT coronary angiography provides similarly diagnostically valuable images in patients with atrial fibrillation and significantly reduces radiation dose.

  17. Initial Experience of the Application of Automated Tube Potential Selection Technique in High-pitch Dual-source CT Angiography of Whole Aorta Using Third-generation Dual-source CT Scanner.

    PubMed

    Kong, Lingyan; Liang, Jixiang; Xue, Huadan; Wang, Yining; Wang, Yun; Jin, Zhengyu; Zhang, Daming; Chen, Jin

    2017-02-20

    Objective To evaluate the application of automated tube potential selection technique in high-pitch dual-source CT aortic angiography on a third-generation dual-source CT scanner. Methods Whole aorta angiography were indiated in 59 patients,who were divided into 2 groups using a simple random method:in group 1 there were 31 patients who underwent the examination with automated tube potential selection using a vascular setting with a preferred image quality of 288 mA/100 kV;in group 2 there were 28 patients who underwent the examination with a tube voltage of 100 kV and automated tube current modulation using a reference tube current of 288 mA. Both groups were scanned on a third generation dual-source CT device operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,collimation of 2×192×0.6 mm,and a rotation time of 0.25 s. Iterative reconstruction algorithm was used. For group 1,the volume and flow of contrast medium and chasing saline were adapted to the tube voltage. For group 2,a contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser at 5 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose (ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 21.3% lower (t=-3.099,P=0.000) in group 1 [(2.48±0.80) mSv] than in group 2 [(3.15±0.86) mSv]. Two groups showed no significant difference in attenuation,SD,SNR,or CNR at all evaluational parts of aorta (ascending aorta,aortic arch,diaphragmatic aorta,or iliac bifurcation)(all P>0.05). There was no significant difference in subjective diagnostic quality values of two groups [(1.41±0.50) scores vs. (1.39±0.50) scores;W=828.5,P=0.837]. Conclusion Compared with automated tube current modulation,the automated tube potential selection technique in aorta CT angiography on a third-generation dual-source CT can dramatically reduce radiation dose without affecting image quality.

  18. High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

    PubMed

    Willinek, Winfried A; Bayer, Thomas; Gieseke, Jürgen; von Falkenhausen, Marcus; Sommer, Torsten; Hoogeveen, Romhild; Wilhelm, Kai; Urbach, Horst; Schild, Hans H

    2007-03-01

    To examine whether the the increased signal-to-noise (S/N) available at 3.0T would permit the use of the quadrature body coil for high spatial resolution contrast-enhanced (CE) MR angiography (MRA), and whether the large FOV that was used in our routine 1.5T protocol would also be feasible at 3.0T. In a prospective study, 43 patients and five volunteers were examined on a clinical whole-body 3.0T MR unit (Intera, Philips Medical Systems, Best, The Netherlands) after institutional review board approval and informed consent. Three-dimensional CE MRA (T1 gradient echo-sequence with TR/TE = 5.7/1.93 msec.; acquisition time, 1:54 min.) using randomly segmented central k-space ordering (CENTRA) was acquired with the quadrature body coil, using over a FOV of 350 mm. A high-image matrix of 432x432 yielded a non-zero filled voxel size of 0.81 mm x 0.81 mm x 1.0 mm (0.66 mm(3)). For quantitative analysis, contrast ratios (CR) between vessels (S) and signal in surrounding tissue (ST) were calculated [(S-ST)/(S+ST)]. For qualitative analysis, image quality and presence of artifacts were rated by two radiologists in consensus on a five-point scale (1=excellent to 5=nondiagnostic). Digital subtraction angiography (DSA) served as the standard of reference in patients with vascular disease. In the five volunteers, 1.5T CE MRA using a phased array neurovascular coil was available for intraindividual comparison. 3.0T CE MRA was successfully performed in 48/48 subjects (100%). Mean CR+/- SD were 0.76 (139.30/182.42) and 0.87 (235.18/270.14) at 3.0T and 1.5T respectively . Mean image quality was 3.82+/-0.86. Intraindividual comparison between 1.5T and 3.0T CE MRA in the volunteers revealed no significant difference in image quality (4.2+/-0.74 vs 4.6+/-0.80; p>0.05). Vascular disease was correctly identified in 13/13 patients with DSA correlation. CE MRA of the supraaortic arteries is feasible at 3.0T using a large FOV of 350 mm. The signal gain at 3.0T enables high spatial resolution contrast-enhanced MR angiography by using the built-in quadrature body coil only.

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    MedlinePlus Videos and Cool Tools

    ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  20. Magnetic resonance angiography of fetal vasculature at 3.0 T.

    PubMed

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Jella, Pavan K; Mody, Swati S; Yadav, Brijesh K; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D; Haacke, Ewart M; Hassan, Sonia S; Romero, Roberto

    2016-12-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. • 3D-visualization of fetal vasculature is feasible using non-contrast MRA at 3.0 T. • Visualization of placental vasculature is also possible with this method. • Fetal MRA can serve as a vascular localizer for quantitative MRI studies. • This method can be extended to 1.5 T.

  1. Management of Spinal Arteriovenous Fistulae with Intraarterial Indocyanine Green Angiography: A Case Report.

    PubMed

    Caglar, Y Sukru; Ozdemir, Mevci; Kahilogullari, Gokmen; Bozkurt, Melih; Attar, Ayhan

    2018-01-01

    We describe herein intraoperative effectiveness of indocyanine green (ICG) video angiography to confirm dural arteriovenous fistulae. A 62-year-old man with a residual symptomatic dural arteriovenous fistula that was previously embolized at another institution is presented. On neurological examination, the motor strength in his both lower extremities was documented as grade 4 and the patella reflex was slightly increased. After verifying the presence of abnormal early venous drainage and retrograde flow with indocyanine green video angiography, the fistula was repaired. Postoperatively there was no additional neurologic deficit. Five days after the operation, the patient was discharged. Intraoperative ICG video angiography provides non-invasive and realtime information, reduction of spinal cord ischemic damage, rapid identification of feeding artery and confirmation of its complete disconnection during surgery, reduction of operative time, and improved outcome with no radiation hazard.

  2. Evolution of digital angiography systems.

    PubMed

    Brigida, Raffaela; Misciasci, Teresa; Martarelli, Fabiola; Gangitano, Guido; Ottaviani, Pierfrancesco; Rollo, Massimo; Marano, Pasquale

    2003-01-01

    The innovations introduced by digital subtraction angiography in digital radiography are briefly illustrated with the description of its components and functioning. The pros and cons of digital subtraction angiography are analyzed in light of present and future imaging technologies. In particular, among advantages there are: automatic exposure, digital image subtraction, digital post-processing, high number of images per second, possible changes in density and contrast. Among disadvantages there are: small round field of view, geometric distortion at the image periphery, high sensitivity to patient movements, not very high spatial resolution. At present, flat panel detectors represent the most suitable substitutes for digital subtraction angiography, with the introduction of novel solutions for those artifacts which for years have hindered its diagnostic validity. The concept of temporal artifact, reset light and possible future evolutions of this technology that may afford both diagnostic and protectionist advantages, are analyzed.

  3. Contrast-enhanced optical coherence microangiography with acoustic-actuated microbubbles

    NASA Astrophysics Data System (ADS)

    Liu, Yu-Hsuan; Zhang, Jia-Wei; Yeh, Chih-Kuang; Wei, Kuo-Chen; Liu, Hao-Li; Tsai, Meng-Tsan

    2017-04-01

    In this study, we propose to use gas-filled microbubbles (MBs) simultaneously actuated by the acoustic wave to enhance the imaging contrast of optical coherence tomography (OCT)-based angiography. In the phantom experiments, MBs can result in stronger backscattered intensity, enabling to enhance the contrast of OCT intensity image. Moreover, simultaneous application of low-intensity acoustic wave enables to temporally induce local vibration of particles and MBs in the vessels, resulting in time-variant OCT intensity which can be used for enhancing the contrast of OCT intensitybased angiography. Additionally, different acoustic modes and different acoustic powers to actuate MBs are performed and compared to investigate the feasibility of contrast enhancement. Finally, animal experiments are performed. The findings suggest that acoustic-actuated MBs can effectively enhance the imaging contrast of OCT-based angiography and the imaging depth of OCT angiography is also extended.

  4. Effectiveness of atrial fibrillation as an independent predictor of death and coronary events in patients having coronary angiography.

    PubMed

    Marte, Thomas; Saely, Christoph H; Schmid, Fabian; Koch, Lorena; Drexel, Heinz

    2009-01-01

    The impact of atrial fibrillation (AF) on future coronary events is uncertain. In particular, the prognostic impact of AF in the clinically important population of coronary patients who undergo angiography is unknown. The aim of this study was to investigate (1) the prevalence of AF, (2) its association with coronary atherosclerosis, and (3) its impact on future coronary events in patients who undergo angiography. Electrocardiograms were evaluated in a consecutive series of 613 patients who underwent coronary angiography. Prospectively, death and cardiovascular events were recorded over 4.0 +/- 0.6 years. Among these patients, 37 (6%) at baseline had AF, and 576 (94%) were in sinus rhythm. The presence of AF was associated with a lower prevalence of coronary artery disease and of coronary diameter narrowing >or=50% on baseline angiography. However, prospectively, patients with AF were at a strongly increased risk for all-cause mortality (adjusted hazard ratio 5.15, 95% confidence interval 2.36 to 11.26, p <0.001), coronary death (hazard ratio 8.16, 95% confidence interval 2.89 to 23.09, p <0.001), and major coronary events (hazard ratio 3.80, 95% confidence interval 1.45 to 9.94, p = 0.007). In conclusion, although inversely associated with the presence of angiographically determined coronary atherosclerosis, AF is a strong predictor of death and future coronary events in patients with coronary artery disease who undergo coronary angiography.

  5. Doppler Fourier Domain Optical Coherence Tomography for Label-Free Tissue Angiography

    NASA Astrophysics Data System (ADS)

    Leitgeb, Rainer A.; Szkulmowski, Maciej; Blatter, Cedric; Wojtkowski, Maciej

    Information about tissue perfusion and the vascular structure is certainly most important for assessment of tissue state or personal health and the diagnosis of any pathological conditions. It is therefore of key medical interest to have tools available for both quantitative blood flow assessment as well as qualitative vascular imaging. The strength of optical techniques is the unprecedented level of detail even for small capillary structures or microaneurysms and the possibility to combine different techniques for additional tissue spectroscopy giving insight into tissue metabolism. There is an immediate diagnostic and pharmacological demand for high-resolution, label-free, tissue angiography and flow assessment that in addition allow for precise depth gating of flow information. The most promising candidate is Doppler optical coherence tomography (DOCT) being noncontact, label free, and without employing hazardous radiation. DOCT provides fully quantitative volumetric information about blood flow together with the vascular and structural anatomy. Besides flow quantification, analysis of OCT signal fluctuations allows to contrast moving scatterers in tissue such as red blood cells from static tissue. This allows for non-invasive optical angiography and yields high resolution even for smallest capillaries. Because of the huge potential of DOCT and lable-free optical angiography for diagnosis, the last years saw a rapid increase of publications in this field with many different approaches. The present chapter gives an overview over existing Doppler OCT approaches and angiography techniques. It furthermore discusses limitations and noise issues, and gives examples for angiography in the eye and the skin.

  6. Comparison of radiological and morphologic assessments of myocardial bridges.

    PubMed

    Ercakmak, Burcu; Bulut, Elif; Hayran, Mutlu; Kaymaz, Figen; Bilgin, Selma; Hazirolan, Tuncay; Bayramoglu, Alp; Erbil, Mine

    2015-09-01

    In this study we aimed to compare the findings of coronary dual-source computed tomography angiography of myocardial bridges with cadaveric dissections. Forty-one isolated, non-damaged fresh sheep hearts were used in this study. Myocardial bridges of the anterior interventricular branch of the left coronary artery were demonstrated and analyzed by a coronary dual-source computed tomography angiography. Dissections along the left anterior interventricular branch of the left coronary artery were performed by using Zeiss OPMI pico microscope and the length of the bridges were measured. The depths of the myocardial bridges were measured from the stained sections by using the light microscope (Leica DM 6000B). MBs were found in all 41 hearts (100%) during dissections. Dual-source computed tomography angiography successfully detected 87.8% (36 of the 41 hearts) of the myocardial bridges measured on left anterior interventricular branch of left coronary artery. The lengths of the myocardial bridges were found 5-40 and 8-50 mm with dissection and dual-source computed tomography angiography, respectively. And the depths were found 0.7-4.5 mm by dual-source computed tomography angiography and 0.745-4.632 mm morphologically. Comparison of the mean values of the lengths showed statistically significantly higher values (22.0 ± 8.5, 17.7 ± 7.7 mm, p = 0.003) for the dissections. Radiological assessment also effectively discriminated complete bridges from incomplete ones. Our study showed that coronary computed tomography angiography is reliable in evaluating the presence and depth of myocardial bridges.

  7. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    PubMed

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  8. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography.

    PubMed

    Zhang, Tao; Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y; Alley, Marcus T; Lustig, Michael; Pauly, John M; Vasanawala, Shreyas S

    2015-10-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children.

  9. Parathyroid gland angiography with indocyanine green fluorescence to predict parathyroid function after thyroid surgery

    PubMed Central

    Vidal Fortuny, J.; Belfontali, V.; Sadowski, S. M.; Karenovics, W.; Guigard, S.

    2016-01-01

    Background Postoperative hypoparathyroidism remains the most common complication following thyroidectomy. The aim of this pilot study was to evaluate the use of intraoperative parathyroid gland angiography in predicting normal parathyroid gland function after thyroid surgery. Methods Angiography with the fluorescent dye indocyanine green (ICG) was performed in patients undergoing total thyroidectomy, to visualize vascularization of identified parathyroid glands. Results Some 36 patients underwent ICG angiography during thyroidectomy. All patients received standard calcium and vitamin D supplementation. At least one well vascularized parathyroid gland was demonstrated by ICG angiography in 30 patients. All 30 patients had parathyroid hormone (PTH) levels in the normal range on postoperative day (POD) 1 and 10, and only one patient exhibited asymptomatic hypocalcaemia on POD 1. Mean(s.d.) PTH and calcium levels in these patients were 3·3(1·4) pmol/l and 2·27(0·10) mmol/l respectively on POD 1, and 4·0(1.6) pmol/l and 2·32(0·08) mmol/l on POD 10. Two of the six patients in whom no well vascularized parathyroid gland could be demonstrated developed transient hypoparathyroidism. None of the 36 patients presented symptomatic hypocalcaemia, and none received treatment for hypoparathyroidism. Conclusion PTH levels on POD 1 were normal in all patients who had at least one well vascularized parathyroid gland demonstrated during surgery by ICG angiography, and none required treatment for hypoparathyroidism. PMID:26864909

  10. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    PubMed

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  11. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona

    2004-01-15

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, themore » DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography.« less

  12. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    NASA Astrophysics Data System (ADS)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  13. Successful treatment of toxoplasmosis-associated choroidal neovascular lesions with bevacizumab and antiparasitic therapy.

    PubMed

    Lin, Chun-Ju; Chen, San-Ni; Hwang, Jiunn-Feng; Hu, Pei-Shin

    2011-01-01

    To report the effects of oral trimethoprim/sulfamethoxazole and intravitreal bevacizumab injection in the treatment of ocular toxoplasmosis-associated choroidal neovascular lesions (CNV). This was a noncomparative, nonrandomized, consecutive case series. All eyes with ocular toxoplasmosis-associated CNV received one intravitreal bevacizumab injection under the coverage of oral trimethoprim/sulfamethoxazole. The changes in best-corrected visual acuity were recorded. Serial fundus photography, fluorescein angiography, optical coherence tomography, and indocyanine green angiography were performed to measure the treatment efficacy. Three eyes of two patients with a history of ocular toxoplasmosis had active CNV demonstrated by fluorescein angiography and optical coherence tomography. Each was treated with oral trimethoprim/sulfamethoxazole and one intravitreal bevacizumab injection. Best-corrected visual acuity, fundus photographs, fluorescein angiography, optical coherence tomography, and indocyanine green angiography all showed favorable results. No ocular or systemic complications were noted. In all three eyes, the CNV subsided and vision improved. Oral trimethoprim/sulfamethoxazole is an effective and less expensive antibiotic against Toxoplasma gondii. Intravitreal bevacizumab injection appears to be a well-tolerated treatment for toxoplasmosis-associated CNV and has the potential as an adjuvant therapy to improve final vision. More cases and further studies are required.

  14. Establishing a successful coronary CT angiography program in the emergency department: official writing of the Fellow and Resident Leaders of the Society of Cardiovascular Computed Tomography (FiRST).

    PubMed

    Maroules, Christopher D; Blaha, Michael J; El-Haddad, Mohamed A; Ferencik, Maros; Cury, Ricardo C

    2013-01-01

    Coronary CT angiography is an effective, evidence-based strategy for evaluating acute chest pain in the emergency department for patients at low-to-intermediate risk of acute coronary syndrome. Recent multicenter trials have reported that coronary CT angiography is safe, reduces time to diagnosis, facilitates discharge, and may lower overall cost compared with routine care. Herein, we provide a 10-step approach for establishing a successful coronary CT angiography program in the emergency department. The importance of strategic planning and multidisciplinary collaboration is emphasized. Patient selection and preparation guidelines for coronary CT angiography are reviewed with straightforward protocols that can be adapted and modified to clinical sites, depending on available cardiac imaging capabilities. Technical parameters and patient-specific modifications are also highlighted to maximize the likelihood of diagnostic quality examinations. Practical suggestions for quality control, process monitoring, and standardized reporting are reviewed. Finally, the role of a "triple rule-out" protocol is featured in the context of acute chest pain evaluation in the emergency department. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  15. BIRDSHOT CHORIORETINITIS LESIONS ON INDOCYANINE GREEN ANGIOGRAPHY AS AN INDICATOR OF DISEASE ACTIVITY.

    PubMed

    Cao, Jennifer H; Silpa-Archa, Sukhum; Freitas-Neto, Clovis A; Foster, C Stephen

    2016-09-01

    To determine whether classical indocyanine green angiography lesions in patients with birdshot chorioretinitis can be used to monitor disease activity. A retrospective case series was performed on 26 eyes in 26 consecutive patients with birdshot chorioretinitis who had at least one indocyanine green angiography performed during disease activity and another during disease quiescence. Using Photoshop, the mean number, area, and area per spot on indocyanine green angiography were compared between disease activity and quiescence using a paired ratio test. The mean total lesion number, area, and area per spot during disease activity were 75.27 spots, 24,525 pixels, and 364 pixels/spots, respectively. The mean total lesion number, area, and area per spot size during disease quiescence were 28.35 spots (P < 0.01), 7,411 pixels (P < 0.01), and 279 pixels/spot (P = 0.12), respectively. There was a statistically significant decrease in the mean total area and number of lesions between the time of disease activity and disease quiescence (P < 0.01). Our results suggest that indocyanine green angiography has a role not only in diagnosis but also in monitoring treatment effectiveness; lesions can be reversible with treatment and their reappearance may be an indicator of disease relapse.

  16. Optimal treatment of coronary-to-pulmonary artery fistula: surgery, coil or stent graft?

    PubMed Central

    Lipiec, Piotr; Peruga, Jan Zbigniew; Jaszewski, Ryszard; Pawłowski, Witold; Kasprzak, Jarosław

    2013-01-01

    We report a case of a 57-year-old man with typical angina due to a coronary artery-to-pulmonary artery fistula, which was evident on transthoracic and transesophageal echocardiography with color Doppler flow mapping. The diagnosis was confirmed by coronary angiography. The patient underwent surgical ligation of the fistula. However, repeated transesophageal echocardiography and coronary angiography revealed persistence of the fistula with significant left-to-right shunt. The orifice of the fistula was then obliterated by stent-graft implantation, which was proven successful by angiography and echocardiography. PMID:24570733

  17. How Strong Is the Evidence for Sodium Bicarbonate to Prevent Contrast-Induced Acute Kidney Injury After Coronary Angiography and Percutaneous Coronary Intervention?

    PubMed

    Dong, Yuhao; Zhang, Bin; Liang, Long; Lian, Zhouyang; Liu, Jing; Liang, Changhong; Zhang, Shuixing

    2016-02-01

    Hydration with sodium bicarbonate is one of the strategies to prevent contrast-induced acute kidney injury (CI-AKI). The purpose of this study was to determine how strong is the evidence for sodium bicarbonate to prevent CI-AKI after coronary angiography (CAG) and/or percutaneous coronary intervention (PCI).We conducted PubMed, EMBASE, and CENTRAL databases to search for randomized controlled trials (RCTs) comparing the efficacy of sodium bicarbonate with sodium chloride to prevent CI-AKI after CAG and/or PCI. Relative risk (RR), standardized mean difference (SMD), or weighted mean difference (WMD) with 95% confidence intervals (CIs) was calculated. Heterogeneity, publication bias, and study quality were evaluated, sensitivity analyses, cumulative analyses, and subgroup analyses were performed. The risk of random errors was assessed by trial sequential analysis (TSA).Sixteen RCTs (3537 patients) met the eligibility criteria. Hydration with sodium bicarbonate showed significant beneficial effects in preventing CI-AKI (RR 0.67; 95% CI: 0.47-0.96, P = 0.029), decreasing the change in serum creatinine (SCr) (SMD -0.31 95% CI: -0.55 to -0.07, P = 0.011) and estimated glomerular filtration rate (eGFR) (SMD -0.17 95% CI: -0.30 to -0.04, P = 0.013). But no significant differences were observed in the requirement for dialysis (RR 1.11; 95% CI: 0.60-2.07, P = 0.729), mortality (RR 0.71; 95% CI: 0.41-1.21, P = 0.204) and reducing the length of hospital stay (LHS) (WMD -1.47; 95% CI: -4.14 to 1.20, P = 0.279). The result of TSA on incidence of CI-AKI showed the required information size (RIS = 6614) was not reached and cumulative z curve did not cross TSA boundary. The result of TSA on the requirement for dialysis and mortality demonstrated the required information sizes (RIS = 170,510 and 19,516, respectively) were not reached, and the cumulative z-curve did not cross any boundaries.The evidence that sodium bicarbonate reduces the incidence of CI-AKI is encouraging but more well-designed randomized controlled trails are required to allow definitive firm conclusion to be drawn.

  18. Hypersensitivity to aspirin and urgent percutaneous coronary intervention: A therapeutic challenge.

    PubMed

    Duarte, Tatiana; Gonçalves, Sara; Sá, Catarina; Marinheiro, Rita; Rodrigues, Rita; Seixo, Filipe; Tomas, Elza; Caria, Rui

    2016-11-01

    Hypersensitivity reactions to nonsteroidal anti-inflammatory drugs are common and five types of reactions have been defined. The prevalence of such reactions in patients with myocardial infarction is unclear, and so antiplatelet therapy in this population is a challenge. Various desensitization protocols have been developed but there are no specific guidelines for their use. The authors present the case of a patient with acute coronary syndrome and aspirin hypersensitivity referred for urgent coronary angiography. Aspirin desensitization therapy is safe and successful in many patients, but more randomized trials are needed to confirm its benefits in coronary artery disease patients. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Evaluation of meglumine gadoterate-enhanced MR angiography (MRA) compared with time-of-flight MRA in the diagnosis of clinically significant non-coronary arterial disease: a pooled analysis of data from two clinical trials

    PubMed Central

    Shah, D J; Lim, T-H

    2012-01-01

    Objectives We analysed pooled data from two clinical trials to assess the diagnostic accuracy and safety of meglumine gadoterate (Gd-DOTA)-enhanced MR angiography (MRA) relative to those of non-enhanced time-of-flight (TOF) MRA for non-coronary arterial disease. Both techniques were compared with X-ray angiography as the gold standard. Methods Patients were of both sexes, were aged at least 18 years and had suspected non-coronary arterial disease. Each patient was his/her own control and underwent TOF MRA followed by Gd-DOTA-enhanced MRA, and then X-ray angiography. MRA was performed at 1.5 T (USA study) or 3 T (Republic of Korea study). The primary criterion used to evaluate efficacy was the degree to which the MRA examination agreed with X-ray angiography in assessing non-coronary arterial lesions. The performance of Gd-DOTA over TOF was assessed using a one-sided paired t-test. We also evaluated the specificity, sensitivity, image quality, examination duration and clinical safety of both MRA procedures. Results In total, 192 patients were enrolled and received Gd-DOTA. In the intent-to-treat population (n=162), within-patient accuracy was significantly greater for Gd-DOTA than for TOF (85.8±19.8% agreement between Gd-DOTA and X-ray angiography compared with 78.3±24.9% agreement between TOF and X-ray angiography; p=0.0001). The sensitivity, specificity, image quality and examination duration were also better for Gd-DOTA than for TOF. There were no serious drug-related adverse events. Conclusion We conclude that Gd-DOTA-enhanced MRA is a safe and accurate procedure for detecting arterial stenosis at both 1.5 T and 3 T. PMID:22167518

  20. Transfers to metropolitan hospitals and coronary angiography for rural Aboriginal and non-Aboriginal patients with acute ischaemic heart disease in Western Australia.

    PubMed

    Lopez, Derrick; Katzenellenbogen, Judith M; Sanfilippo, Frank M; Woods, John A; Hobbs, Michael S T; Knuiman, Matthew W; Briffa, Tom G; Thompson, Peter L; Thompson, Sandra C

    2014-05-01

    Aboriginal people have a disproportionately higher incidence rate of ischaemic heart disease (IHD) than non-Aboriginal people. The findings on Aboriginal disparity in receiving coronary artery procedures are inconclusive. We describe the profile and transfers of IHD patients admitted to rural hospitals as emergency admissions and investigate determinants of transfers and coronary angiography. Person-linked hospital and mortality records were used to identify 28-day survivors of IHD events commencing at rural hospitals in Western Australia. Outcome measures were receipt of coronary angiography, transfer to a metropolitan hospital, and coronary angiography if transferred to a metropolitan hospital. Compared to non-Aboriginal patients, Aboriginal patients with IHD were more likely to be younger, have more co-morbidities, reside remotely, but less likely to have private insurance. After adjusting for demographic characteristics, Aboriginal people with MI were less likely to be transferred to a metropolitan hospital, and if transferred were less likely to receive coronary angiography. These disparities were not significant after adjusting for comorbidities and private insurance. In the full multivariate model age, comorbidities and private insurance were adversely associated with transfer to a metropolitan hospital and coronary angiography. Disparity in receiving coronary angiography following emergency admission for IHD to rural hospitals is mediated through the lower likelihood of being transferred to metropolitan hospitals where this procedure is performed. The likelihood of a transfer is increased if the patient has private insurance, however, rural Aboriginal people have a lower rate of private insurance than their non-Aboriginal counterparts. Health practitioners and policy makers can continue to claim that they treat Aboriginal and non-Aboriginal people alike based upon clinical indications, as private insurance is acting as a filter to reduce rural residents accessing interventional cardiology. If health practitioners and policy makers are truly committed to reducing health disparities, they must reflect upon the broader systems in which disparity is perpetuated and work towards a systems improvement.

  1. Prospective trial of angiography and embolization for all grade III to V blunt splenic injuries: nonoperative management success rate is significantly improved.

    PubMed

    Miller, Preston R; Chang, Michael C; Hoth, J Jason; Mowery, Nathan T; Hildreth, Amy N; Martin, R Shayn; Holmes, James H; Meredith, J Wayne; Requarth, Jay A

    2014-04-01

    Nonoperative management (NOM) of blunt splenic injury is well accepted. Substantial failure rates in higher injury grades remain common, with one large study reporting rates of 19.6%, 33.3%, and 75% for grades III, IV, and V, respectively. Retrospective data show angiography and embolization can increase salvage rates in these severe injuries. We developed a protocol requiring referral of all blunt splenic injuries, grades III to V, without indication for immediate operation for angiography and embolization. We hypothesized that angiography and embolization of high-grade blunt splenic injury would reduce NOM failure rates in this population. This was a prospective study at our Level I trauma center as part of a performance-improvement project. Demographics, injury characteristics, and outcomes were compared with historic controls. The protocol required all stable patients with grade III to V splenic injuries be referred for angiography and embolization. In historic controls, referral was based on surgeon preference. From January 1, 2010 to December 31, 2012, there were 168 patients with grades III to V spleen injuries admitted; NOM was undertaken in 113 (67%) patients. The protocol was followed in 97 patients, with a failure rate of 5%. Failure rate in the 16 protocol deviations was 25% (p = 0.02). Historic controls from January 1, 2007 to December 31, 2009 were compared with the protocol group. One hundred and fifty-three patients with grade III to V injuries were admitted during this period, 80 (52%) patients underwent attempted NOM. Failure rate was significantly higher than for the protocol group (15%, p = 0.04). Use of a protocol requiring angiography and embolization for all high-grade spleen injuries slated for NOM leads to a significantly decreased failure rate. We recommend angiography and embolization as an adjunct to NOM for all grade III to V splenic injuries. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Detecting active pelvic arterial haemorrhage on admission following serious pelvic fracture in multiple trauma patients.

    PubMed

    Brun, Julien; Guillot, Stéphanie; Bouzat, Pierre; Broux, Christophe; Thony, Frédéric; Genty, Céline; Heylbroeck, Christophe; Albaladejo, Pierre; Arvieux, Catherine; Tonetti, Jérôme; Payen, Jean-Francois

    2014-01-01

    The early diagnosis of pelvic arterial haemorrhage is challenging for initiating treatment by transcatheter arterial embolization (TAE) in multiple trauma patients. We use an institutional algorithm focusing on haemodynamic status on admission and on a whole-body CT scan in stabilized patients to screen patients requiring TAE. This study aimed to assess the effectiveness of this approach. This retrospective cohort study included 106 multiple trauma patients admitted to the emergency room with serious pelvic fracture [pelvic abbreviated injury scale (AIS) score of 3 or more]. Of the 106 patients, 27 (25%) underwent pelvic angiography leading to TAE for active arterial haemorrhage in 24. The TAE procedure was successful within 3h of arrival in 18 patients. In accordance with the algorithm, 10 patients were directly admitted to the angiography unit (n=8) and/or operating room (n=2) for uncontrolled haemorrhagic shock on admission. Of the remaining 96 stabilized patients, 20 had contrast media extravasation on pelvic CT scan that prompted pelvic angiography in 16 patients leading to TAE in 14. One patient underwent a pelvic angiography despite showing no contrast media extravasation on pelvic CT scan. All 17 stabilized patients who underwent pelvic angiography presented a more severely compromised haemodynamic status on admission, and they required more blood products during their initial management than the 79 patients who did not undergo pelvic angiography. The incidence of unstable pelvic fractures was however comparable between the two groups. Overall, haemodynamic instability and contrast media extravasation on the CT-scan identified 26 out of the 27 patients who required subsequent pelvic angiography leading to TAE in 24. An algorithm focusing on haemodynamic status on arrival and on the whole-body CT scan in stabilized patients may be effective at triaging multiple trauma patients with serious pelvic fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Comparison of standard- and low-tube voltage 320-detector row volume CT angiography in detection of intracranial aneurysms with digital subtraction angiography as gold standard.

    PubMed

    Sun, Gang; Ding, Juan; Lu, Yang; Li, Min; Li, Li; Li, Guo-ying; Zhang, Xu-ping

    2012-03-01

    The aim of this study was to prospectively assess the effect of low-tube voltage (80 kVp) 320-detector row volume computed tomographic (CT) angiography (L-VCTA) in the detection of intracranial aneurysms, with three-dimensional (3D) spin digital subtraction angiography (DSA) as the gold standard. Forty-eight patients with clinically suspected subarachnoid hemorrhages were divided into two groups. One group underwent L-VCTA and DSA, while the other group underwent conventional-tube voltage (120 kVp) volume CT angiography (C-VCTA) and DSA. Vascular enhancement, image quality, detection accuracy of aneurysms, and radiation dose were compared between the two groups. For objective image quality, the L-VCTA group had higher mean vessel attenuation, correlated with higher image noise and lower signal-to-noise ratio, than the C-VCTA group. For subjective image quality, there were no significant differences between the two groups regarding scores for arterial enhancement, depiction of small arterial detail, interference of venous structures, and overall image quality scores. The mean effective dose for the L-VCTA group was significantly lower than for the C-VCTA group (0.56 ± 0.25 vs 1.84 ± 0.002 mSv), with a reduction of radiation dose of 69.73%. With 3D DSA as the reference standard, the sensitivity, specificity, and accuracy in the L-VCTA and C-VCTA groups were 94.12%, 100%, 94.4% and 100%, 100%, and 100%, respectively. In both groups, there were significant correlations for maximum aneurysm diameter measurements between volume CT angiography and 3D DSA; no statistical difference in the mean maximum diameter of each aneurysm was measured between volume CT angiography and 3D DSA. L-VCTA is helpful in detecting intracranial aneurysms, with results similar to those of 3D DSA, but at a lower radiation dose than C-VCTA. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  4. Cardiac Medication Use in Patients with Acute Myocardial Infarction and Nonobstructive Coronary Artery Disease.

    PubMed

    Adatia, Falisha; Galway, Shannon; Grubisic, Maja; Lee, May; Daniele, Patrick; Humphries, Karin H; Sedlak, Tara L

    2017-11-01

    Patients with acute myocardial infarction (MI) and nonobstructive coronary artery disease (CAD) have an elevated cardiac event rate, suggesting that these patients may benefit from cardiac medication. We evaluated the rates of cardiac medication use 3 months before angiography and 3 months following clinically indicated angiography for MI in patients with no CAD, nonobstructive CAD, and obstructive CAD. We also examined the sex differences in cardiac medication use 3 months following angiography in patients by extent of angiographic CAD. We studied patients ≥20 years old with MI undergoing coronary angiography in British Columbia, Canada, from January 1, 2008, to March 31, 2010 (n = 3,841). No CAD, nonobstructive CAD, and obstructive CAD were defined as 0%, 1% to 49%, and ≥50% luminal narrowing in any epicardial coronary artery, respectively. Medication use, 3 months before and 3 months following angiography, was obtained through British Columbia PharmaNet for angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), calcium channel blockers (CCBs), beta-blockers, statins, and antiplatelet agents. Optimal medical therapy (OMT) was defined as filled prescriptions for all three: ACE-Is/ARBs, beta-blockers, and statins. Following angiography, in all medication categories except CCBs, patients with no CAD and nonobstructive CAD had significantly lower rates of prescriptions filled than patients with obstructive CAD (all p < 0.001). After adjusting for age and prior medication use, patients with nonobstructive CAD were still less likely to receive these medications than patients with obstructive CAD, including OMT with an odds ratio = 0.25 (95% confidence interval: 0.18-0.36). There were no significant sex differences in medication use 3 months postangiography. In post-MI patients, medication use following angiography is significantly lower in nonobstructive CAD than obstructive CAD at 3 months. While sex was not an independent predictor of medication use 3 months post-catheterization, future studies should explore methods of improving medication use in both females and males with nonobstructive CAD post-MI.

  5. Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma

    PubMed Central

    Jia, Yali; Wei, Eric; Wang, Xiaogang; Zhang, Xinbo; Morrison, John C.; Parikh, Mansi; Lombardi, Lori H.; Gattey, Devin M.; Armour, Rebecca L.; Edmunds, Beth; Kraus, Martin F.; Fujimoto, James G.; Huang, David

    2014-01-01

    Purpose To compare optic disc perfusion between normal and glaucoma subjects using optical coherence tomography (OCT) angiography and detect optic disc perfusion changes in glaucoma. Design Observational, cross-sectional study. Participants Twenty-four normal subjects and 11 glaucoma patients were included. Methods One eye of each subject was scanned by a high-speed 1050 nm wavelength swept-source OCT instrument. The split-spectrum amplitude-decorrelation angiography algorithm (SSADA) was used to compute three-dimensional optic disc angiography. A disc flow index was computed from four registered scans. Confocal scanning laser ophthalmoscopy (cSLO) was used to measure disc rim area, and stereo photography was used to evaluate cup/disc ratios. Wide field OCT scans over the discs were used to measure retinal nerve fiber layer (NFL) thickness. Main Outcome Measurements Variability was assessed by coefficient of variation (CV). Diagnostic accuracy was assessed by sensitivity and specificity. Comparisons between glaucoma and normal groups were analyzed by Wilcoxon rank-sum test. Correlations between disc flow index, structural assessments, and visual field (VF) parameters were assessed by linear regression. Results In normal discs, a dense microvascular network was visible on OCT angiography. This network was visibly attenuated in glaucoma subjects. The intra-visit repeatability, inter-visit reproducibility, and normal population variability of the optic disc flow index were 1.2%, 4.2%, and 5.0% CV respectively. The disc flow index was reduced by 25% in the glaucoma group (p = 0.003). Sensitivity and specificity were both 100% using an optimized cutoff. The flow index was highly correlated with VF pattern standard deviation (R2 = 0.752, p = 0.001). These correlations were significant even after accounting for age, cup/disc area ratio, NFL, and rim area. Conclusions OCT angiography, generated by the new SSADA algorithm, repeatably measures optic disc perfusion. OCT angiography could be useful in the evaluation of glaucoma and glaucoma progression. PMID:24629312

  6. Mono-Energy Coronary Angiography with a Compact Synchrotron Source

    NASA Astrophysics Data System (ADS)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noёl, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-02-01

    X-ray coronary angiography is an invaluable tool for the diagnosis of coronary artery disease. However, the use of iodine-based contrast media can be contraindicated for patients who present with chronic renal insufficiency or with severe iodine allergy. These patients could benefit from a reduced contrast agent concentration, possibly achieved through application of a mono-energetic x-ray beam. While large-scale synchrotrons are impractical for daily clinical use, the technology of compact synchrotron sources strongly advanced during the last decade. Here we present a quantitative analysis of the benefits a compact synchrotron source can offer in coronary angiography. Simulated projection data from quasi-mono-energetic and conventional x-ray tube spectra is used for a CNR comparison. Results show that compact synchrotron spectra would allow for a significant reduction of contrast media. Experimentally, we demonstrate the feasibility of coronary angiography at the Munich Compact Light Source, the first commercial installation of a compact synchrotron source.

  7. Pelvic packing or angiography: competitive or complementary?

    PubMed

    Suzuki, Takashi; Smith, Wade R; Moore, Ernest E

    2009-04-01

    Pelvic angiography is an established technique that has evolved into a highly effective means of controlling arterial pelvic haemorrhage. The current dominant paradigm for haemodynamically unstable patients with pelvic fractures is angiographic management combined with mechanical stabilisation of the pelvis. However, an effective rapid screening tool for arterial bleeding in pelvic fracture patients has yet to be identified. There is also no precise way to determine the major source of bleeding responsible for haemodynamic instability. In many pelvic fracture patients, bleeding is from venous lacerations which are not effectively treated with angiography to fractured bony surfaces. Modern pelvic packing consists of time-saving and minimally invasive techniques which appear to result in effective control of the haemorrhage via tamponade. This review article focuses on the recent body of knowledge on angiography and pelvic packing. We propose the optimal role for each modality in trauma centres.

  8. Evaluation of Intraocular Inflammation with Laser Flare Photometry in Behçet Uveitis.

    PubMed

    Yalcindag, Fatime Nilufer; Bingol Kiziltunc, Pinar; Savku, Esra

    2017-02-01

    To evaluate the association between intraocular inflammation and laser flare photometry measurements in Behçet disease. In total, 45 patients were included in the study. The retrospective chart reviews of patients were performed. The flare levels were compared with the grade of anterior chamber cells, the presence of vitreous cells, the complications of uveitis, and fluorescein angiography scores. The attack group had higher flare intensity; the flare levels were higher in both groups compared with the values of healthy controls. The flare levels were related to the grade of the anterior chamber cells, the presence of vitreous cells and the fluorescein angiography scores. Patients with optic atrophy and/or maculopathy also had higher values. Higher flare values were correlated with poor vision. Laser flare photometry may reduce the necessity of fluorescein angiography in monitoring subclinical inflammation and may be an indicator of posterior segment activity when fluorescein angiography is not applicable.

  9. CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions.

    PubMed

    Zhang, Qiang; Zhang, Zhiqiang; Yang, Jiakang; Sun, Qi; Luo, Yongchun; Shan, Tonghui; Zhang, Hao; Han, Jingfeng; Liang, Chunyang; Pan, Wenlong; Gu, Chuanqi; Mao, Gengsheng; Xu, Ruxiang

    2016-08-01

    Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebral vessels, and tested the feasibility of using preprocedural MRA for real-time guidance during endovascular procedures.Twenty-three patients with suspected intracranial arterial lesions were enrolled. The contrast medium-enhanced 3D DSA of target vessels were acquired in 19 patients during endovascular procedures, and the images were registered with preprocedural MRA for fusion accuracy evaluation. Low-dose noncontrasted 3D angiography of the skull was performed in the other 4 patients, and registered with the MRA. The MRA was overlaid afterwards with 2D live fluoroscopy to guide endovascular procedures.The 3D registration of the MRA and angiography demonstrated a high accuracy for vessel lesion visualization in all 19 patients examined. Moreover, MRA of the intracranial vessels, registered to the noncontrasted 3D angiography in the 4 patients, provided real-time 3D roadmap to successfully guide the endovascular procedures. Radiation dose to patients and contrast medium usage were shown to be significantly reduced.Three-dimensional MRA and angiography fusion can accurately generate cerebral vasculature images to guide endovascular procedures. The use of the fusion technology could enhance clinical workflow while minimizing contrast medium usage and radiation dose, and hence lowering procedure risks and increasing treatment safety.

  10. CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions

    PubMed Central

    Zhang, Qiang; Zhang, Zhiqiang; Yang, Jiakang; Sun, Qi; Luo, Yongchun; Shan, Tonghui; Zhang, Hao; Han, Jingfeng; Liang, Chunyang; Pan, Wenlong; Gu, Chuanqi; Mao, Gengsheng; Xu, Ruxiang

    2016-01-01

    Abstract Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebral vessels, and tested the feasibility of using preprocedural MRA for real-time guidance during endovascular procedures. Twenty-three patients with suspected intracranial arterial lesions were enrolled. The contrast medium-enhanced 3D DSA of target vessels were acquired in 19 patients during endovascular procedures, and the images were registered with preprocedural MRA for fusion accuracy evaluation. Low-dose noncontrasted 3D angiography of the skull was performed in the other 4 patients, and registered with the MRA. The MRA was overlaid afterwards with 2D live fluoroscopy to guide endovascular procedures. The 3D registration of the MRA and angiography demonstrated a high accuracy for vessel lesion visualization in all 19 patients examined. Moreover, MRA of the intracranial vessels, registered to the noncontrasted 3D angiography in the 4 patients, provided real-time 3D roadmap to successfully guide the endovascular procedures. Radiation dose to patients and contrast medium usage were shown to be significantly reduced. Three-dimensional MRA and angiography fusion can accurately generate cerebral vasculature images to guide endovascular procedures. The use of the fusion technology could enhance clinical workflow while minimizing contrast medium usage and radiation dose, and hence lowering procedure risks and increasing treatment safety. PMID:27512846

  11. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    NASA Astrophysics Data System (ADS)

    Schültke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Estève, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-08-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible.

  12. Effects of Peer-Facilitated, Video-Based and Combined Peer-and-Video Education on Anxiety Among Patients Undergoing Coronary Angiography: Randomised controlled trial.

    PubMed

    Habibzadeh, Hosein; Milan, Zahra D; Radfar, Moloud; Alilu, Leyla; Cund, Audrey

    2018-02-01

    Coronary angiography can be stressful for patients and anxiety-caused physiological responses during the procedure increase the risk of dysrhythmia, coronary artery spasms and rupture. This study therefore aimed to investigate the effects of peer, video and combined peer-and-video training on anxiety among patients undergoing coronary angiography. This single-blinded randomised controlled clinical trial was conducted at two large educational hospitals in Iran between April and July 2016. A total of 120 adult patients undergoing coronary angiography were recruited. Using a block randomisation method, participants were assigned to one of four groups, with those in the control group receiving no training and those in the three intervention groups receiving either peer-facilitated training, video-based training or a combination of both. A Persian-language validated version of the State-Trait Anxiety Inventory was used to measure pre- and post-intervention anxiety. There were no statistically significant differences in mean pre-intervention anxiety scores between the four groups (F = 0.31; P = 0.81). In contrast, there was a significant reduction in post-intervention anxiety among all three intervention groups compared to the control group (F = 27.71; P <0.01); however, there was no significant difference in anxiety level in terms of the type of intervention used. Peer, video and combined peer-and-video education were equally effective in reducing angiography-related patient anxiety. Such techniques are recommended to reduce anxiety amongst patients undergoing coronary angiography in hospitals in Iran.

  13. Is There a Role for Empiric Gastroduodenal Artery Embolization in the Management of Patients with Active Upper GI Hemorrhage?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, Shaheen, E-mail: shaheen7noorani@gmail.com; Chan, Victoria, E-mail: dr.victoriac@gmail.com; Shrivastava, Vivek, E-mail: vivshriv@yahoo.com

    2013-08-01

    PurposeTo assess the relative efficacy of empiric gastroduodenal artery (GDA) embolization in reducing recurrent hemorrhage compared to image-guided targeted embolization.MethodsData were retrospectively collected for consecutive patients who had catheter angiography for major upper gastrointestinal hemorrhage from May 2008 to November 2010 (n = 40). The total number of cases were divided into two main groups according to angiographic findings: those that demonstrated a site of hemorrhage on catheter angiography (group 1, n = 13), and those where the site of hemorrhage was not identified on catheter angiography (group 2, n = 27). Group 2 was then further divided into patientsmore » who received empiric embolization (group 2a, n = 20) and those who had no embolization performed after angiography (group 2b, n = 7).ResultsThe technical and clinical success rates for embolization in groups 1 and 2a were, respectively, 100 vs. 95 %, and 85 vs. 80 %. There was no statistical significance in the recurrent hemorrhage rate, reintervention rate, or 30 day mortality between targeted and empiric embolization groups. There were no complications attributed to embolization within this study cohort.ConclusionCases of duodenal-related major upper gastrointestinal hemorrhage where no embolization is performed have poor outcome. Empiric embolization of the GDA in patients with major upper gastrointestinal hemorrhage refractory to endoscopic treatment appears to be a safe and effective treatment, with low reintervention rates and good clinical outcome comparable to patients where the site of hemorrhage is localized and embolized with computed tomographic angiography or catheter angiography and embolized.« less

  14. Pediatric head and neck lesions: assessment of vascularity by MR digital subtraction angiography.

    PubMed

    Chooi, Weng Kong; Woodhouse, Neil; Coley, Stuart C; Griffiths, Paul D

    2004-08-01

    Pediatric head and neck lesions can be difficult to characterize on clinical grounds alone. We investigated the use of dynamic MR digital subtraction angiography as a noninvasive adjunct for the assessment of the vascularity of these abnormalities. Twelve patients (age range, 2 days to 16 years) with known or suspected vascular abnormalities were studied. Routine MR imaging, time-of-flight MR angiography, and MR digital subtraction angiography were performed in all patients. The dynamic sequence was acquired in two planes at one frame per second by using a thick section (6-10 cm) selective radio-frequency spoiled fast gradient-echo sequence and an IV administered bolus of contrast material. The images were subtracted from a preliminary mask sequence and viewed as a video-inverted cine loop. In all cases, MR digital subtraction angiography was successfully performed. The technique showed the following: 1) slow flow lesions (two choroidal angiomas, eyelid hemangioma, and scalp venous malformation); 2) high flow lesions that were not always suspected by clinical examination alone (parotid hemangioma, scalp, occipital, and eyelid arteriovenous malformations plus a palatal teratoma); 3) a hypovascular tumor for which a biopsy could be safely performed (Burkitt lymphoma); and 4) a hypervascular tumor of the palate (cystic teratoma). Our early experience suggests that MR digital subtraction angiography can be reliably performed in children of all ages without complication. The technique provided a noninvasive assessment of the vascularity of each lesion that could not always have been predicted on the basis of clinical examination or routine MR imaging alone.

  15. Automatic segmentation and co-registration of gated CT angiography datasets: measuring abdominal aortic pulsatility

    NASA Astrophysics Data System (ADS)

    Wentz, Robert; Manduca, Armando; Fletcher, J. G.; Siddiki, Hassan; Shields, Raymond C.; Vrtiska, Terri; Spencer, Garrett; Primak, Andrew N.; Zhang, Jie; Nielson, Theresa; McCollough, Cynthia; Yu, Lifeng

    2007-03-01

    Purpose: To develop robust, novel segmentation and co-registration software to analyze temporally overlapping CT angiography datasets, with an aim to permit automated measurement of regional aortic pulsatility in patients with abdominal aortic aneurysms. Methods: We perform retrospective gated CT angiography in patients with abdominal aortic aneurysms. Multiple, temporally overlapping, time-resolved CT angiography datasets are reconstructed over the cardiac cycle, with aortic segmentation performed using a priori anatomic assumptions for the aorta and heart. Visual quality assessment is performed following automatic segmentation with manual editing. Following subsequent centerline generation, centerlines are cross-registered across phases, with internal validation of co-registration performed by examining registration at the regions of greatest diameter change (i.e. when the second derivative is maximal). Results: We have performed gated CT angiography in 60 patients. Automatic seed placement is successful in 79% of datasets, requiring either no editing (70%) or minimal editing (less than 1 minute; 12%). Causes of error include segmentation into adjacent, high-attenuating, nonvascular tissues; small segmentation errors associated with calcified plaque; and segmentation of non-renal, small paralumbar arteries. Internal validation of cross-registration demonstrates appropriate registration in our patient population. In general, we observed that aortic pulsatility can vary along the course of the abdominal aorta. Pulsation can also vary within an aneurysm as well as between aneurysms, but the clinical significance of these findings remain unknown. Conclusions: Visualization of large vessel pulsatility is possible using ECG-gated CT angiography, partial scan reconstruction, automatic segmentation, centerline generation, and coregistration of temporally resolved datasets.

  16. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    PubMed

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  17. Coronary heart disease is not significantly linked to acute kidney injury identified using Acute Kidney Injury Group criteria.

    PubMed

    Yayan, Josef

    2012-01-01

    Patients with unstable angina or myocardial infarction are at risk of acute kidney injury, which may be aggravated by the iodine-containing contrast agent used during coronary angiography; however, the relationship between these two conditions remains unclear. The current study investigated the relationship between acute kidney injury and coronary heart disease prior to coronary angiography. All patients were evaluated after undergoing coronary angiography in the cardiac catheterization laboratory of the Vinzentius Hospital in Landau, Germany, in 2011. The study group included patients with both acute coronary heart disease and acute kidney injury (as defined according to the classification of the Acute Kidney Injury Group); the control group included patients without acute coronary heart disease. Serum creatinine profiles were evaluated in all patients, as were a variety of demographic and health characteristics. Of the 303 patients examined, 201 (66.34%) had coronary artery disease. Of these, 38 (18.91%) also had both acute kidney injury and acute coronary heart disease prior to and after coronary angiography, and of which in turn 34 (16.91%) had both acute kidney injury and acute coronary heart disease only prior to the coronary angiography. However, the occurrence of acute kidney injury was not significantly related to the presence of coronary heart disease (P = 0.95, Chi-square test). The results of this study indicate that acute kidney injury is not linked to acute coronary heart disease. However, physicians should be aware that many coronary heart patients may develop kidney injury while hospitalized for angiography.

  18. Vascularized osseous flaps and assessing their bipartate perfusion pattern via intraoperative fluorescence angiography.

    PubMed

    Valerio, Ian; Green, J Marshall; Sacks, Justin M; Thomas, Shane; Sabino, Jennifer; Acarturk, T Oguz

    2015-01-01

    Large segmental bone and composite tissue defects often require vascularized osseous flaps for definitive reconstruction. However, failed osseous flaps due to inadequate perfusion can lead to significant morbidity. Utilization of indocyanine green (ICG) fluorescence angiography has been previously shown to reliably assess soft tissue perfusion. Our group will outline the application of this useful intraoperative tool in evaluating the perfusion of vascularized osseous flaps. A retrospective review was performed to identify those osseous and/or osteocutaneous bone flaps, where ICG angiography was employed. Data analyzed included flap types, success and failure rates, and perfusion-related complications. All osseous flaps were evaluated by ICG angiography to confirm periosteal and endosteal perfusion. Overall 16 osseous free flaps utilizing intraoperative ICG angiography to assess vascularized osseous constructs were performed over a 3-year period. The flaps consisted of the following: nine osteocutaneous fibulas, two osseous-only fibulas, two scapular/parascapular with scapula bone, two quadricep-based muscle flaps, containing a vascularized femoral bone component, and one osteocutaneous fibula revision. All flap reconstructions were successful with the only perfusion-related complication being a case of delayed partial skin flap loss. Intraoperative fluorescence angiography is a useful adjunctive tool that can aid in flap design through angiosome mapping and can also assess flap perfusion, vascular pedicle flow, tissue perfusion before flap harvest, and flap perfusion after flap inset. Our group has successfully extended the application of this intraoperative tool to assess vascularized osseous flaps in an effort to reduce adverse outcomes related to preventable perfusion-related complications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Comparison of duplex ultrasound with digital subtraction angiography in the assessment of infra-inguinal autologous vein bypass grafts.

    PubMed

    Griffin, Nick M R; Wright, Isabel A; Buckenham, Tim M

    2006-11-01

    Postoperative surveillance of infra-inguinal vein grafts has arisen because of the high incidence of vein graft stenoses, which frequently progress to vein graft occlusion. The use of duplex ultrasound as the primary imaging method for graft surveillance is well established. This study aims to compare the accuracy of duplex ultrasound with the reference standard of digital subtraction angiography in the assessment of infra-inguinal vein grafts. Sixty patients underwent routine postoperative duplex ultrasound as part of the local graft surveillance programme. Angiography was subsequently carried out on 18 grafts. Each lower limb arterial tree was divided into three segments (native arteries proximal to the graft, the graft itself and native arteries distal to the graft) resulting in a total of 42 comparisons. Degree of diameter stenosis on ultrasound was compared with angiography findings to determine concordance. Agreement was also expressed as a kappa value. Overall accuracy of duplex ultrasound was 88% (37/42). A kappa value of 0.80 indicates good agreement. In three of the five discordant cases, ultrasound correctly identified a stenosis, but overestimated the degree of stenosis compared with angiography. In each of the remaining two discordant cases, ultrasound identified a focal stenosis that was not apparent on angiography. In both cases, the area of duplex described abnormality responded to balloon angioplasty. Duplex ultrasound as part of the local vein graft surveillance programme is a reliable and accurate method in the detection of failing grafts and in some instances may be more sensitive.

  20. Diagnostic performance of multi-slice CT angiography combined with enterography for small bowel obstruction and intestinal ischaemia.

    PubMed

    He, Bosheng; Gu, Jinhua; Huang, Sheng; Gao, Xuesong; Fan, Jinhe; Sheng, Meihong; Wang, Lin; Gong, Shenchu

    2017-02-01

    This study was performed to evaluate the diagnostic performance of multi-slice CT angiography combined with enterography in determining the cause and location of obstruction as well as intestinal ischaemia in patients with small bowel obstruction (SBO). This study retrospectively summarized the image data of 57 SBO patients who received both multi-slice CT angiography and enterography examination between December 2012 and May 2013. The CT diagnoses of SBO and intestinal ischaemia were correlated with the findings at surgery or digital subtraction angiography, which were set as standard references. Multi-slice CT angiography and enterography indicated that the cause of SBO in three patients was misjudged, suggesting a diagnostic accuracy of 94.7%. In one patient the level of obstruction was incorrect, demonstrating a diagnostic accuracy of 98.2%. Based on the results of the receiver operating characteristic (ROC) curve analysis, the diagnostic criterion for ischaemic SBO was at least two of the four CT signs (circumferential bowel wall thickening, reduced enhancement of the intestinal wall, mesenteric oedema and mesenteric vascular engorgement). The criterion yielded a sensitivity of 94.4%, a specificity of 92.3%, a positive predicted value of 85.0% and a negative predicted value of 97.3%, and the area under curve (AUC) was 0.92 (95% CI, 0.85-0.99). Multi-slice CT angiography and enterography have high diagnostic value in identifying the cause and site of SBO. In addition, the suggested diagnostic criterion using CT signs is helpful for diagnosing intestinal ischaemia in SBO patients. © 2016 The Royal Australian and New Zealand College of Radiologists.

  1. Acute Fulminant Uremic Neuropathy Following Coronary Angiography Mimicking Guillain-Barre Syndrome.

    PubMed

    Priti, Kumari; Ranwa, Bhanwar

    2017-01-01

    A 55-year-old diabetic woman suffered a posterior wall ST-elevation myocardial infarction. She developed contrast-induced nephropathy following coronary angiography. Acute fulminant uremic neuropathy was precipitated which initially mimicked Guillan-Barre Syndrome, hence reported.

  2. The increased use of computed tomography angiography and magnetic resonance angiography as the sole imaging modalities prior to infrainguinal bypass has had no effect on outcomes.

    PubMed

    Shue, Bing; Damle, Rachelle N; Flahive, Julie; Kalish, Jeffrey A; Stone, David H; Patel, Virendra I; Schanzer, Andres; Baril, Donald T

    2015-08-01

    Angiography remains the gold standard imaging modality before infrainguinal bypass. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) have emerged as noninvasive alternatives for preoperative imaging. We sought to examine contemporary trends in the utilization of CTA and MRA as isolated imaging modalities before infrainguinal bypass and to compare outcomes following infrainguinal bypass in patients who underwent CTA or MRA versus those who underwent conventional arteriography. Patients undergoing infrainguinal bypass within the Vascular Study Group of New England were identified (2003-2012). Patients were stratified by preoperative imaging modality: CTA/MRA alone or conventional angiography. Trends in utilization of these modalities were examined and demographics of these groups were compared. Primary end points included primary patency, secondary patency, and major adverse limb events (MALE) at 1 year as determined by Kaplan-Meier analysis. Multivariable Cox proportional hazards models were constructed to evaluate the effect of imaging modality on primary patency, secondary patency, and MALE after adjusting for confounders. In 3123 infrainguinal bypasses, CTA/MRA alone was used in 462 cases (15%) and angiography was used in 2661 cases (85%). Use of CTA/MRA alone increased over time, with 52 (11%) bypasses performed between 2003 and 2005, 189 (41%) bypasses performed between 2006 and 2009, and 221 (48%) bypasses performed between 2010 and 2012 (P < 0.001). Patients with CTA/MRA alone, compared with patients with angiography, more frequently underwent bypass for claudication (33% vs. 26%, P = 0.001) or acute limb ischemia (13% vs. 5%, P < 0.0001), more frequently had prosthetic conduits (39% vs. 30%, P = 0.001), and less frequently had tibial/pedal targets (32% vs. 40%, P = 0.002). After adjusting for these and other confounders, multivariable analysis demonstrated that the use of CTA/MRA alone was not associated with a significant difference in 1 year primary patency (hazard ratio [HR] 0.95, 95% confidence interval [CI] 0.78-1.16), secondary patency (HR 1.30, 95% CI 0.99-1.72), or MALE (HR 1.08, 95% CI 0.89-1.32). CTA and MRA are being increasingly used as the sole preoperative imaging modality before infrainguinal bypass. This shift in practice patterns appears to have no measurable effect on outcomes at 1 year. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Combining stereotactic angiography and 3D time-of-flight magnetic resonance angiography in treatment planning for arteriovenous malformation radiosurgery.

    PubMed

    Bednarz, G; Downes, B; Werner-Wasik, M; Rosenwasser, R H

    2000-03-15

    This study was initiated to evaluate the advantages of using three-dimensional time-of-flight magnetic resonance angiography (3D TOF MRA), as an adjuvant to conventional stereotactic angiography, in obtaining three-dimensional information about an arteriovenous malformation (AVM) nidus and in optimizing radiosurgical treatment plans. Following angiography, contrast-enhanced MRI and MRA studies were obtained in 22 consecutive patients undergoing Gamma Knife radiosurgery for AVM. A treatment plan was designed, based on the angiograms and modified as necessary, using the information provided by MRA. The quantitative analysis involved calculation of the ratio of the treated volume to the MRA nidus volume (the tissue volume ratio [TVR]) for the initial and final treatment plans. In 12 cases (55%), the initial treatment plans were modified after including the MRA information in the treatment planning process. The mean TVR for the angiogram-based plans was 1.63 (range 1.17-2.17). The mean coverage of the MRA nidus by the angiogram-based plans was 93% (range 73-99%). The mean MRA nidus volume was 2.4 cc (range 0. 6-5.3 cc). The MRA-based modifications resulted in increased conformity with the mean TVR of 1.46 (range 1.20-1.74). These modifications were caused by MRA revealing irregular nidi and/or vascular components superimposed on the angiographic projections of the nidi. In a number of cases, the information from MRA was essential in defining the nidus when the projections of the angiographic outlines showed different superior and/or inferior extent of the nidus. In two cases, MRA revealed irregular nidi, correlating well with the angiograms and showed that the angiographically acceptable plans undertreated 27% of the MRA nidus in one case and 18% of the nidus in the other case. In the remaining 10 cases (45%), both MRI and MRA failed to detect the nidus due to surgical clip artifacts and the presence of embolizing glue. The 3D TOF MRA provided information on irregular AVM shape, which was not visualized by angiography alone, and it was superior to MRI for defining the AVM nidus. However, when imaging artifacts obscured the AVM nidus on MRI and MRA, angiography permitted detection of AVM. Utilizing MRA as a complementary imaging modality to angiography increased accuracy of the AVM radiosurgery and allowed for optimal dose planning.

  4. Acute Fulminant Uremic Neuropathy Following Coronary Angiography Mimicking Guillain–Barre Syndrome

    PubMed Central

    Priti, Kumari; Ranwa, Bhanwar

    2017-01-01

    A 55-year-old diabetic woman suffered a posterior wall ST-elevation myocardial infarction. She developed contrast-induced nephropathy following coronary angiography. Acute fulminant uremic neuropathy was precipitated which initially mimicked Guillan–Barre Syndrome, hence reported. PMID:28706599

  5. Coronary microvascular dysfunction equivalent to left main coronary artery disease.

    PubMed

    Panç, Cafer; Kocaağa, Mehmet; Erdoğan, Onur; Sarıkaya, Remzi; Umman, Sabahattin

    2017-04-01

    Coronary microvascular dysfunction, also known as cardiac syndrome X, is a clinical syndrome presenting with typical angina and evidence of myocardial ischemia in the absence of flow-limiting stenosis on coronary angiography. Of patients undergoing coronary angiography due to suspected myocardial ischemia, 50% are found to have normal or near-normal coronary arteries. Described in this case report is a patient who developed hypotension and ST segment depressions during treadmill exercise test. Left main coronary artery or multivessel disease was suspected. Coronary angiography was normal, but coronary flow reserve measurement revealed severe microvascular dysfunction.

  6. Peripheral vascular tumors and vascular malformations: imaging (magnetic resonance imaging and conventional angiography), pathologic correlation and treatment options.

    PubMed

    El-Merhi, Fadi; Garg, Deepak; Cura, Marco; Ghaith, Ola

    2013-02-01

    Vascular anomalies are classified into vascular tumors (infantile hemangioma) and vascular malformations. Vascular malformations are divided into slow flow and high flow subtypes. Magnetic resonance imaging helps in classification and assessing extent and distribution. Conventional angiography also known as digital subtraction angiography is pivotal in assessment of fine vascular details and treatment planning. Imaging correlates well with histopathology. We review recent development in imaging techniques of various vascular anomalies most of which are affecting the peripheral system which potentially may broaden understanding of their diagnosis, classification and treatment.

  7. Contemporary retinal imaging techniques in diabetic retinopathy: a review.

    PubMed

    Cole, Emily Dawn; Novais, Eduardo Amorim; Louzada, Ricardo Noguera; Waheed, Nadia K

    2016-05-01

    Over the last decade, there has been an expansion of imaging modalities available to clinicians to diagnose and monitor the treatment and progression of diabetic retinopathy. Recently, advances in image technologies related to OCT and OCT angiography have enabled improved visualization and understanding of this disease. In this review, we will describe the use of imaging techniques such as colour fundus photography, fundus autofluorescence, fluorescein angiography, infrared reflectance imaging, OCT, OCT-Angiography and techniques in adaptive optics and hyperspectral imaging in the diagnosis and management of diabetic retinopathy. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  8. Spontaneous rectus sheath hematoma: The utility of CT angiography.

    PubMed

    Pierro, Antonio; Cilla, Savino; Modugno, Pietro; Centritto, Enrico Maria; De Filippo, Carlo Maria; Sallustio, Giuseppina

    2018-04-01

    We described the utility of computed tomography (CT) angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization.

  9. Indocyanine green video angiography predicts outcome of extravasation injuries.

    PubMed

    Haslik, Werner; Pluschnig, Ursula; Steger, Günther G; Zielinski, Christoph C; Schrögendorfer, K F; Nedomansky, Jakob; Bartsch, Rupert; Mader, Robert M

    2014-01-01

    Extravasation of cytotoxic drugs is a serious complication of systemic cancer treatment. Still, a reliable method for early assessment of tissue damage and outcome prediction is missing. Here, we demonstrate that the evaluation of blood flow by indocyanine green (ICG) angiography in the extravasation area predicts for the need of surgical intervention. Twenty-nine patients were evaluated by ICG angiography after extravasation of vesicant or highly irritant cytotoxic drugs administered by peripheral i.v. infusion. Tissue perfusion as assessed by this standardized method was correlated with clinical outcome. The perfusion index at the site of extravasation differed significantly between patients with reversible tissue damage and thus healing under conservative management (N = 22) versus those who needed surgical intervention due to the development of necrosis (N = 7; P = 0.0001). Furthermore, in patients benefiting from conservative management, the perfusion index was significantly higher in the central extravasation area denoting hyperemia, when compared with the peripheral area (P = 0.0001). In this patient cohort, ICG angiography as indicator of local perfusion within the extravasation area was of prognostic value for tissue damage. ICG angiography could thus be used for the early identification of patients at risk for irreversible tissue damage after extravasation of cytotoxic drugs.

  10. Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

    PubMed

    Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C

    2016-10-10

    The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

  11. MULTIMODAL IMAGING OF CHOROIDAL LESIONS IN DISSEMINATED MYCOBACTERIUM CHIMAERA INFECTION AFTER CARDIOTHORACIC SURGERY.

    PubMed

    Böni, Christian; Al-Sheikh, Mayss; Hasse, Barbara; Eberhard, Roman; Kohler, Philipp; Hasler, Pascal; Erb, Stefan; Hoffmann, Matthias; Barthelmes, Daniel; Zweifel, Sandrine A

    2017-12-04

    To explore morphologic characteristics of choroidal lesions in patients with disseminated Mycobacterium chimaera infection subsequent to open-heart surgery. Nine patients (18 eyes) with systemic M. chimaera infection were reviewed. Activity of choroidal lesions were evaluated using biomicroscopy, fundus autofluorescence, enhanced depth imaging optical coherence tomography, fluorescein angiography/indocyanine green angiography, and optical coherence tomography angiography. Relationships of choroidal findings to systemic disease activity were sought. All 9 male patients, aged between 49 and 66 years, were diagnosed with endocarditis and/or aortic graft infection. Mean follow-up was 17.6 months. Four patients had only inactive lesions (mild disease). In all five patients (10 eyes) with progressive ocular disease, indocyanine green angiography was superior to other tests for revealing new lesions and active lesions correlated with hyporeflective choroidal areas on enhanced depth imaging optical coherence tomography. One eye with a large choroidal granuloma developed choroidal neovascularization. Optical coherence tomography angiography showed areas with reduced perfusion at the inner choroid. All 5 patients with progressive ocular disease had evidence of systemic disease activity within ±6 weeks' duration. Choroidal manifestation of disseminated M. chimaera infection indicates systemic disease activity. Multimodal imaging is suitable to recognize progressive ocular disease. We propose ophthalmologic screening examinations for patients with M. chimaera infection.

  12. Postmortem dynamic cerebral angiography for detecting aneurysm and bleeding sites in cases of subarachnoid hemorrhage.

    PubMed

    Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro

    2014-12-01

    One of the advantages of postmortem imaging is its ability to obtain diagnostic findings in a non-destructive manner when autopsy is either difficult or may destroy forensic evidence. In recent years, efforts have been made to incorporate computed tomography (CT) based postmortem angiography into forensic pathology; however, it is not currently clear how well the modality can determine sites of bleeding in cases of subarachnoid hemorrhage. Therefore, in this study, we investigated the utility of postmortem cerebral angiography using multi-detector row CT (MDCT) by injecting a contrast medium through a catheter inserted into the internal carotid and vertebral arteries of 10 subarachnoid hemorrhage cases. While postmortem MDCT angiography (PMCTA) was capable of detecting aneurysms in a non-destructive manner, it was sometimes difficult to identify the aneurysm and bleeding sites because of a large amount of contrast medium leaking into the extravascular space. To overcome this problem, we developed the novel contrast imaging method "dynamic cerebral angiography," which involves scanning the same area multiple times while injecting contrast medium to enable real-time observation of the contrasted vasculature. Using multiphase contrast images acquired by this method, we successfully captured the moment when contrast medium leaked from the hemorrhage site. This method will be useful for identifying exact bleeding sites on PMCTA.

  13. Multidetector CT angiography in living donor renal transplantation: accuracy and discrepancies in right venous anatomy.

    PubMed

    Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G

    2011-01-01

    Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.

  14. Urinary KIM-1, NGAL and L-FABP for the diagnosis of AKI in patients with acute coronary syndrome or heart failure undergoing coronary angiography.

    PubMed

    Torregrosa, Isidro; Montoliu, Carmina; Urios, Amparo; Andrés-Costa, María Jesús; Giménez-Garzó, Carla; Juan, Isabel; Puchades, María Jesús; Blasco, María Luisa; Carratalá, Arturo; Sanjuán, Rafael; Miguel, Alfonso

    2015-11-01

    Acute kidney injury (AKI) is a common complication after coronary angiography. Early biomarkers of this disease are needed since increase in serum creatinine levels is a late marker. To assess the usefulness of urinary kidney injury molecule-1 (uKIM-1), neutrophil gelatinase-associated lipocalin (uNGAL) and liver-type fatty acid-binding protein (uL-FABP) for early detection of AKI in these patients, comparing their performance with another group of cardiac surgery patients. Biomarkers were measured in 193 patients, 12 h after intervention. In the ROC analysis, AUC for KIM-1, NGAL and L-FABP was 0.713, 0.958 and 0.642, respectively, in the coronary angiography group, and 0.716, 0.916 and 0.743 in the cardiac surgery group. Urinary KIM-1 12 h after intervention is predictive of AKI in adult patients undergoing coronary angiography, but NGAL shows higher sensitivity and specificity. L-FABP provides inferior discrimination for AKI than KIM-1 or NGAL in contrast to its performance after cardiac surgery. This is the first study showing the predictive capacity of KIM-1 for AKI after coronary angiography. Further studies are still needed to answer relevant questions about the clinical utility of biomarkers for AKI in different clinical settings.

  15. Controversies in the treatment of patients with STEMI and multivessel disease: is it time for PCI of all lesions?

    PubMed

    Ong, Peter; Sechtem, Udo

    2016-06-01

    Several randomized trials have suggested a benefit for multivessel PCI in patients with STEMI and multivessel disease. However, none of the studies compared multivessel PCI with a staged PCI-approach which is the current guideline recommended approach. The results of the trials may overestimate the beneficial effect of the multivessel PCI approach because the control group did not receive any ischaemia testing for evaluation of the significance of remaining lesions. Thus, unfavourable aspects of the multivessel PCI approach such as overestimation of non-culprit lesions at the time of acute coronary angiography, complications associated with PCI of the non-culprit lesion (i.e. dissection, no-reflow, acute stent thrombosis) or increased risk for contrast induced nephropathy may have gone unnoticed as the comparative management pathway was unusual and likely inferior to the guideline recommended approach. We believe that culprit lesion only PCI and staged evaluation of remaining areas of myocardial ischaemia with subsequent PCI is still preferable in patients with STEMI and multivessel disease but a randomized study comparing this approach with multivessel PCI is needed.

  16. [Cardiac protection is a clinical evidence].

    PubMed

    Guarracino, F; Doroni, L; Cariello, C; Baldassarri, R; Vullo, C

    2004-05-01

    Anaesthetics may have protective effect against myocardial ischemia. We aimed to investigate if sevoflurane administration could exert myocardial protection during following coronary occlusion in patients with coronary artery disease. a). prospective, randomized study. b). University Hospital, cardiac surgical operative theatre. c). 42 patients with coronary artery disease, scheduled to undergo coronary surgery. severe coronary stenosis of anterior descending coronary artery; no collateral flow on angiography; at least two normokinetic segments in the myocardial region supplied by the vessel being bypassed. PATIENTS were randomized to receive (group S) or not (group C) sevoflurane administration for 15 min just before coronary occlusion. d). Transoesophageal Tissue Doppler echocardiographic examination of myocardial systolic and early diastolic velocities in both groups basally and 60 s after coronary occlusion by the surgeon. e). systolic and early diastolic velocities were registered by Tissue Doppler from a long-axis view of the interventricular septum or the anterior wall of the left ventricle. In group C a significant reduction of systolic and diastolic intramyocardial velocities was found during myocardial ischemia due to coronary occlusion. Treatment with sevoflurane before coronary occlusion seem effective in reducing functional myocardial impairment due to ischemia.

  17. MULTIMODAL IMAGING IN VORTEX VEIN VARICES.

    PubMed

    Veronese, Chiara; Staurenghi, Giovanni; Pellegrini, Marco; Maiolo, Chiara; Primavera, Laura; Morara, Mariachiara; Armstrong, Grayson W; Ciardella, Antonio P

    2017-03-22

    The aim of this study is to describe the clinical presentation of vortex vein varices with multimodal imaging. The authors carried out a retrospective case series of eight patients (7 female, 1 male) with an average age of 60.2 years (min 8, max 84, median 68.5) presenting with vortex vein varices. All patients were evaluated at the Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy and at Luigi Sacco Hospital, University of Milan, Milan, Italy. Patients underwent complete ophthalmologic examinations, including best corrected visual acuity, intraocular pressure, anterior segment, and fundus examination. Imaging studies, including fundus color photography, near-infrared reflectance imaging, fundus autofluorescence, fluorescein angiography, indocyanine green angiography, and spectral-domain enhanced depth imaging optical coherence tomography were also performed. Ultra-widefield fluorescein angiography and ultra-widefield indocyanine angiography using the Heidelberg Retina Angiograph and the Staurenghi 230 SLO Retina Lens were used to demonstrate the disappearance of all retinal lesions when pressure was applied to the globe. All eight cases initially presented to the emergency room. One patient presented secondary to trauma, two patients presented for suspected hemangioma, whereas the other five were referred to the authors' hospitals for suspected retinal lesions. On examination, retinal abnormalities were identified in all 8 patients, with 7 (87.5%) oculus dexter and 1 (12.5%) oculus sinister, and with 1 (12.5%) inferotemporally, 3 (37.5%) superonasally, 3 (37.5%) inferonasally, and 1 (12.5%) inferiorly. Fundus color photography showed an elevated lesion in seven patients and a nonelevated red lesion in one patient. In all patients, near-infrared reflectance imaging showed a hyporeflective lesion in the periphery of the retina. Fundus autofluorescence identified round hypofluorescent rings surrounding weakly hyperfluorescent lesions in all patients. On fluorescein angiography, all lesions were initially hyperfluorescent with a hypofluorescent ring, with the lesion becoming hyperfluorescent after injection of dye. Indocyanine green angiography demonstrated dilation of the vortex vein ampullae in all patients. Spectral-domain enhanced depth imaging optical coherence tomography demonstrated dilated choroidal vessels and a hyporeflective cavity without subretinal fluid in all patients. Ultra-widefield fluorescein angiography and ultra-widefield indocyanine angiography demonstrated disappearance of all retinal lesions when pressure was applied to the globe. Findings are consistent with the diagnosis of vortex vein varix in all eight patients, with six patients (75%) exhibiting a single varix and two patients (25%) exhibiting a double varix. The diagnosis of vortex vein varices can be confirmed through clinical examination through the use of digital pressure to the globe during ophthalmoscopic examination. Adjunctive multimodal imaging (fundus color photography, near-infrared reflectance imaging, fundus autofluorescence, fluorescein angiography, indocyanine angiography, and spectral-domain enhanced depth imaging optical coherence tomography) was useful in the diagnosis of vortex vein varices in the authors' clinical cases. However, in more challenging clinical cases, the authors' novel use of the ultra-widefield contact lens for application of ocular pressure with a resulting resolution of the varix proved to be a useful and easy diagnostic imaging method for confirming the presence of vortex vein varices.

  18. Breast surface radiation dose during coronary CT angiography: reduction by breast displacement and lead shielding.

    PubMed

    Foley, Shane J; McEntee, Mark F; Achenbach, Stephan; Brennan, Patrick C; Rainford, Louise S; Dodd, Jonathan D

    2011-08-01

    The purpose of this study was to prospectively evaluate the effect of cranial breast displacement and lead shielding on in vivo breast surface radiation dose in women undergoing coronary CT angiography. Fifty-four women (mean age, 59.2 ± 9.8 years) prospectively underwent coronary 64-MDCT angiography for evaluation of chest pain. The patients were randomly assigned to a control group (n = 16), breast displacement group (n = 22), or breast displacement plus lead shielding group (n = 16). Thermoluminescent dosimeters (TLDs) were placed superficially on each breast quadrant and the areolar region of both breasts. Breast surface radiation doses, the degree of breast displacement, and coronary image quality were compared between groups. A phantom dose study was conducted to compare breast doses with z-axis positioning on the chest wall. A total of 1620 TLD dose measurements were recorded. Compared with control values, the mean breast surface dose was reduced 23% in the breast displacement group (24.3 vs 18.6 mGy, p = 0.015) and 36% in the displacement plus lead shielding group (24.3 vs 15.6 mGy, p = 0.0001). Surface dose reductions were greatest in the upper outer (displacement alone, 66%; displacement plus shielding, 63%), upper inner (65%, 58%), and areolar quadrants (44%, 53%). The smallest surface dose reductions were recorded for A-cup breasts: 7% for the displacement group and 3% for the displacement plus lead group (p = 0.741). Larger reductions in surface dose were recorded for B-cup (25% and 56%, p = 0.273), C-cup (38% and 60%, p = 0.001), and D-cup (31% and 25%, p = 0.095) sizes. Most of the patients (79%) had either good (< 50% of breast above scan range) or excellent (< 75% of breast above the scan range) breast displacement. No significant difference in coronary image quality was detected between groups. The phantom dose study showed that surface TLD measurements were underestimates of absorbed tissue dose by a mean of 9% and that a strong negative correlation exists between the amount of cranial displacement and breast dose. Use of breast displacement during coronary CTA substantially reduces the radiation dose to the breast surface.

  19. SU-E-I-25: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Simulation Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, T; Ding, H; Lipinski, J

    2015-06-15

    Purpose: To develop a physics-based model for accurate quantification of the cross-sectional area (CSA) of coronary arteries in CT angiography by measuring the integrated density to account for the partial volume effect. Methods: In this technique the integrated density of the object as compared with its local background is measured to account for the partial volume effect. Normal vessels were simulated as circles with diameters in the range of 0.1–3mm. Diseased vessels were simulated as 2, 3, and 4mm diameter vessels with 10–90% area stenosis, created by inserting circular plaques. A simplified two material model was used with the lumenmore » as 8mg/ml Iodine and background as lipid. The contrast-to-noise ratio between lumen and background was approximately 26. Linear fits to the known CSA were calculated. The precision and accuracy of the measurement were quantified using the root-mean-square fit deviations (RMSD) and errors to the known CSA (RMSE). Results compared to manual segmentation of the vessel lumen. To assess the impact of random variations, coefficients of variation (CV) from 10 simulations for each vessel were computed to determine reliability. Measurements with CVs less than 10% were considered reliable. Results: For normal vessels, the precision and accuracy of the integrated density technique were 0.12mm{sup 2} and 0.28mm{sup 2}, respectively. The corresponding results for manual segmentation were 0.27mm{sup 2} and 0.43mm{sup 2}. For diseased vessels, the precision and accuracy of the integrated density technique were 0.14mm{sup 2} and 0.19mm{sup 2}. Corresponding results for manual segmentation were 0.42mm{sup 2} and 0.71mm{sup 2}. Reliable CSAs were obtained for normal vessels with diameters larger than 1 mm and for diseased vessels with area as low as 1.26mm2. Conclusion: The CSA based on integrated density showed improved precision and accuracy as compared with manual segmentation in simulation. These results indicate the potential of using integrated density to quantify CSA of coronary arteries in CT angiography.« less

  20. Contrast Media Administration in Coronary Computed Tomography Angiography - A Systematic Review.

    PubMed

    Mihl, Casper; Maas, Monique; Turek, Jakub; Seehofnerova, Anna; Leijenaar, Ralph T H; Kok, Madeleine; Lobbes, Marc B I; Wildberger, Joachim E; Das, Marco

    2017-04-01

    Background  Various different injection parameters influence enhancement of the coronary arteries. There is no consensus in the literature regarding the optimal contrast media (CM) injection protocol. The aim of this study is to provide an update on the effect of different CM injection parameters on the coronary attenuation in coronary computed tomographic angiography (CCTA). Method  Studies published between January 2001 and May 2014 identified by Pubmed, Embase and MEDLINE were evaluated. Using predefined inclusion criteria and a data extraction form, the content of each eligible study was assessed. Initially, 2551 potential studies were identified. After applying our criteria, 36 studies were found to be eligible. Studies were systematically assessed for quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-II checklist. Results  Extracted data proved to be heterogeneous and often incomplete. The injection protocol and outcome of the included publications were very diverse and results are difficult to compare. Based on the extracted data, it remains unclear which of the injection parameters is the most important determinant for adequate attenuation. It is likely that one parameter which combines multiple parameters (e. g. IDR) will be the most suitable determinant of coronary attenuation in CCTA protocols. Conclusion  Research should be directed towards determining the influence of different injection parameters and defining individualized optimal IDRs tailored to patient-related factors (ideally in large randomized trials). Key points   · This systematic review provides insight into decisive factors on coronary attenuation.. · Different and contradicting outcomes are reported on coronary attenuation in CCTA.. · One parameter combining multiple parameters (IDR) is likely decisive in coronary attenuation.. · Research should aim at defining individualized optimal IDRs tailored to individual factors.. · Future directions should be tailored towards the influence of different injection parameters.. Citation Format · Mihl C, Maas M, Turek J et al. Contrast Media Administration in Coronary Computed Tomography Angiography - A Systematic Review. Fortschr Röntgenstr 2017; 189: 312 - 325. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Use of 3×2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies

    PubMed Central

    Schuetz, Georg M; Schlattmann, Peter

    2012-01-01

    Objective To determine whether a 3×2 table, using an intention to diagnose approach, is better than the “classic” 2×2 table at handling transparent reporting and non-evaluable results, when assessing the accuracy of a diagnostic test. Design Based on a systematic search for diagnostic accuracy studies of coronary computed tomography (CT) angiography, full texts of relevant studies were evaluated to determine whether they could calculate an alternative 3×2 table. To quantify an overall effect, we pooled diagnostic accuracy values according to a meta-analytical approach. Data sources Medline (via PubMed), Embase (via Ovid), and ISI Web of Science electronic databases. Eligibility criteria Prospective English or German language studies comparing coronary CT with conventional coronary angiography in all patients and providing sufficient data for a patient level analysis. Results 120 studies (10 287 patients) were eligible. Studies varied greatly in their approaches to handling non-evaluable findings. We found 26 studies (including 2298 patients) that allowed us to calculate both 2×2 tables and 3×2 tables. Using a bivariate random effects model, we compared the 2×2 table with the 3×2 table, and found significant differences for pooled sensitivity (98.2 (95% confidence interval 96.7 to 99.1) v 92.7 (88.5 to 95.3)), area under the curve (0.99 (0.98 to 1.00) v 0.93 (0.91 to 0.95)), positive likelihood ratio (9.1 (6.2 to 13.3) v 4.4 (3.3 to 6.0)), and negative likelihood ratio (0.02 (0.01 to 0.04) v 0.09 (0.06 to 0.15); (P<0.05)). Conclusion Parameters for diagnostic performance significantly decrease if non-evaluable results are included by a 3×2 table for analysis (intention to diagnose approach). This approach provides a more realistic picture of the clinical potential of diagnostic tests. PMID:23097549

  2. Adopting an early invasive strategy for non-ST-elevation myocardial infarction: Analysis of the Portuguese Registry on Acute Coronary Syndromes.

    PubMed

    Morgado, Gonçalo; Pereira, Hélder; Caldeira, Daniel

    2018-01-01

    In patients with non-ST-elevation myocardial infarction (NSTEMI), the best timing for coronary angiography is not definitely established, although it is recognized that in high-risk patients it should be performed within the first 24 hours. The aim of this work was to describe the evolution over time of the use of an invasive strategy in the treatment of NSTEMI and in-hospital mortality. We performed a retrospective analysis of patients admitted with NSTEMI included in the Portuguese Registry on Acute Coronary Syndromes (ProACS) between 2002 and 2015. The annual proportion of patients undergoing coronary angiography and the time from admission to coronary angiography were assessed, as were changes in mortality and length of stay. A total of 18 639 patients with NSTEMI were included in the ProACS registry between 2002 and 2015. Over this period there were significant increases in the proportion of patients undergoing coronary angiography (from 52.0 to 83.6%) and angioplasty (from 23.3 to 53.0%), as well as in the proportion of patients who underwent coronary angiography within 24 hours of admission (from 21.0 to 48.1%). In-hospital mortality decreased in those aged over 74 years (from 9.5 to 3.7%) and in males. The progressive adoption of an invasive strategy, particularly an early one (within 24 hours), was accompanied by a reduction in in-hospital mortality. Since coronary angiography is performed late (>24 hours) in half of NSTEMI patients, these patients could benefit from initiatives similar to Stent for Life. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Image Quality and Stenosis Assessment of Non-Contrast-Enhanced 3-T Magnetic Resonance Angiography in Patients with Peripheral Artery Disease Compared with Contrast-Enhanced Magnetic Resonance Angiography and Digital Subtraction Angiography

    PubMed Central

    Liu, Jiayi; Zhang, Nan; Fan, Zhaoyang; Luo, Nan; Zhao, Yike; Bi, Xiaoming; An, Jing; Chen, Zhong; Liu, Dongting; Wen, Zhaoying; Fan, Zhanming; Li, Debiao

    2016-01-01

    Purpose To evaluate the diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) magnetic resonance angiography (MRA) at 3 T for imaging infragenual arteries relative to contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA). Materials and Methods A series of 16 consecutive patients with peripheral arterial disease (PAD) underwent a combined peripheral MRA protocol consisting of FSD-MRA for the calves and large field-of-view CE-MRA. DSA was performed on all patients within 1 week of the MR angiographies. Image quality and degree of stenosis was assessed by two readers with rich experience. Inter-observer agreement was determined using kappa statistics. Receiver operating characteristic (ROC) curve analysis determined the diagnostic value of FSD-MRA, CE-MRA, and CE-MRA combined with FSD-MRA (CE+FSD MRA) in predicting vascular stenosis. Results At the calf station, no significantly difference of subjective image quality scores was found between FSD-MRA and CE-MRA. Inter-reader agreement was excellent for both FSD-MRA and CE-MRA. Both of FSD-MRA and CE-MRA carry a stenosis overestimation risk relative to DSA standard. With DSA as the reference standard, ROC curve analysis showed that the area under the curve was largest for CE+FSD MRA. The greatest sensitivity and specificity were obtained when a cut-off stenosis score of 2 was used. Conclusion In patients with severe PAD,3 T FSD-MRA provides good-quality diagnostic images without a contrast agent and is a good supplement for CE-MRA. CE+FSD MRA can improve the accuracy of vascular stenosis diagnosis. PMID:27861626

  4. Clinical relevance of coronary angiography at the time of percutaneous closure of a patent foramen ovale.

    PubMed

    Wahl, Andreas; Praz, Fabien; Seiler, Christian; Windecker, Stephan; Meier, Bernhard

    2007-11-01

    The value of incidental coronary angiography during percutaneous shunt closure to screen for asymptomatic coronary artery disease (CAD) is unknown. On the occasion of percutaneous closure of patent foramen ovale (PFO), incidental coronary angiography routinely offered to men >40 and women >50 years, or younger patients with particular risk patterns, was performed in 575 patients (64% men, mean age 55 +/- 10 years, mean 1.5 +/- 1.1 cardiovascular risk factors) without overt history, signs, or symptoms of CAD. CAD was found in 164 patients (29%); 53 (9%) had >or=50% diameter stenoses. Thirty patients (5%) had one-vessel, 13 (2%) two-vessel, and 10 (2%) three-vessel disease. Patients with CAD (n = 164) were older (60 +/- 9 vs. 53 +/- 10 years; P < 0.0001), more frequently male (76% vs. 59%; P = 0.0002), and had a higher body mass index (26.5 +/- 4.0 vs. 25.4 +/- 4.6; P = 0.006) and more cardiovascular risk factors (2.0 +/- 1.1 vs. 1.2 +/- 1.0; P < 0.0001). There were six procedural complications (1%). Two were unequivocally related to coronary angiography: one minor stroke (diplopia), and one iatrogenic dissection of the right coronary ostium requiring stenting. Furthermore, four arteriovenous fistulae at the puncture site requiring elective surgical closure were possibly related to coronary angiography. Forty-five patients (8% of total) underwent percutaneous (n = 43) or surgical (n = 2) revascularization. In selected asymptomatic patients referred for percutaneous PFO closure, incidental coronary angiography discloses a rather high prevalence of clinically unsuspected CAD. These findings are relevant not only for timely revascularization but also for maintenance of long-term antiplatelet therapy beyond the few months recommended after PFO closure. (c) 2007 Wiley-Liss, Inc.

  5. Accuracy of computed tomographic angiography for stenosis quantification using quantitative coronary angiography or intravascular ultrasound as the gold standard.

    PubMed

    Joshi, Subodh B; Okabe, Teruo; Roswell, Robert O; Weissman, Gaby; Lopez, Cristian F; Lindsay, Joseph; Pichard, Augusto D; Weissman, Neil J; Waksman, Ron; Weigold, Wm Guy

    2009-10-15

    Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.

  6. The Contemporary Use of Angiography and Revascularization Among Patients With Non-ST-Segment Elevation Myocardial Infarction in the United States Compared With South Korea.

    PubMed

    Kang, Hyun-Jae; Simon, Dajuanicia; Wang, Tracy Y; Alexander, Karen P; Jeong, Myung Ho; Kim, Hyo-Soo; Bates, Eric R; Henry, Timothy D; Peterson, Eric D; Roe, Matthew T

    2015-12-01

    Practice guidelines recommend an early invasive strategy for high-risk non-ST-segment elevation myocardial infarction (NSTEMI) patients, but international differences in the use of invasive strategies are unknown. Profiling NSTEMI patient management in the United States (U.S.) and South Korea could provide insight into how patients are triaged for an early invasive strategy in different health care environments and geographical regions. We evaluated the use of angiography and revascularization for NSTEMI patients treated at revascularization-capable hospitals (2007-2010) in both the ACTION Registry-GWTG (U.S.: n = 133,835; 433 hospitals) and KAMIR/KorMI Registry (South Korea: n = 7,901; 72 hospitals). Compared with South Korean patients, U.S. NSTEMI patients more commonly had established cardiovascular risk factors, disease, and prior cardiovascular events and procedures. From 2007-2010, the use of angiography for NSTEMI patients rose steadily in both countries, but the use of revascularization only rose in South Korea. Patients from South Korea more commonly underwent angiography and revascularization. Percutaneous coronary intervention was the most common type of revascularization in both countries, but coronary artery bypass grafting was less common in South Korea. The use of both angiography and revascularization was incrementally lower with a higher predicted mortality risk for patients from both countries, but greater differences between low- and high-risk patients occurred in the U.S. The profile, characteristics, and use of angiography and revascularization for NSTEMI patients in the U.S. vs South Korea differed substantially from 2007-2010, underscoring the heterogeneity of NSTEMI patients and treatment selection among different countries. © 2015 Wiley Periodicals, Inc.

  7. Coronary Events and Anatomy After Arterial Switch Operation for Transposition of the Great Arteries: Detection by 16-Row Multislice Computed Tomography Angiography in Pediatric Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oztunc, Funda, E-mail: foztunc@yahoo.com; Baris, Safa, E-mail: safabaris@hotmail.co; Adaletli, Ibrahim, E-mail: iadaletli@yahoo.com

    2009-03-15

    The purpose of this study was to evaluate the feasibility of multislice computed tomographic (MSCT) angiography as a noninvasive method for detecting ostial, proximal, and middle segment coronary stenosis or occlusion and anatomy in patients with transposition of the great arteries who had undergone arterial switch operation (ASO). Sixteen-detector-row MSCT angiography was performed in 16 patients treated with ASO for transposition of the great arteries. The median age was 10.3 years (range, 6.2-16.3 years). Sixteen-detector-row MSCT angiography was performed in 16 patients who had undergone ASO. CT imaging was performed in the craniocaudal direction from 2 cm above the carinamore » up to the heart basis. Noninvasive assessment of coronary artery stenosis and anatomy were investigated by MSCT angiography. Two patients were excluded from the study because of artifacts. Of 14 evaluated patients, 1 patient had ostial stenosis (7.1%). A coronary artery anatomy variant was present in six patients: left main artery (LMA) and right coronary artery (RCA) originating from the right sinus as a single orifice (n = 2); left circumflex artery (LCX) originating from the RCA (n = 1); LMA and RCA, after branching to the LCX, originating separately from the right sinus (n = 1); and LMA (n = 1) and left anterior descending artery (LADA; n = 1) originating directly from the right sinus. Intramural bridging in the LAD (n = 2) was detected. Five patients were normal. In conclusion, MSCT angiography, as a noninvasive, feasible technique for assessing coronary stenosis or occlusion and anatomy, can be used in the follow-up of patients who have undergone ASO.« less

  8. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications.

    PubMed

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-12-01

    To evaluate the radiation exposure for operating personnel associated with rotational flat-panel angiography and C-arm cone beam CT. Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8s/rotation, 20s/rotation and 5s/2 rotations), and 47 cm×18 cm (16s/2 rotations) and standard 2D angiography (10s, FOV 24 cm×18 cm). Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8s/rotation: 28.0 μSv, 20s/rotation: 79.3 μSv, 5s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20s/rotation). Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts.

    PubMed

    Plessis, Julien; Warin Fresse, Karine; Cahouch, Zachary; Manigold, Thibaut; Letocart, Vincent; Le Gloan, Laurianne; Guyomarch, Béatrice; Guerin, Patrice

    2016-06-10

    Coronary angiography is more complex in patients with coronary artery bypass grafts (CABG). Image fusion is a new technology that allows the overlay of a computed tomography (CT) three-dimension (3D) model with fluoroscopic images in real time. This single-center prospective study included 66 previous CABG patients undergoing coronary and bypass graft angiography. Image fusion coronary angiographies (fusion group, 20 patients) were compared to conventional coronary angiographies (control group, 46 patients). The fusion group included patients for whom a previous chest CT scan with contrast was available. For patients in this group, aorta and CABG were reconstructed in 3D from CT acquisitions and merged in real time with fluoroscopic images. The following parameters were compared: time needed to localize the CABG; procedure duration; air kerma (AK); dose area product (DAP); and volume of contrast media injected. Results are expressed as median. There were no significant differences between the 2 groups in patient demographics and procedure characteristics (access site, number of bypass to be found, and interventional cardiologist's experience). The time to localize CABG was significantly shorter in the fusion group (7.3 versus 12.4 minutes; P=0.002), as well as the procedure duration (20.6 versus 25.6 minutes; P=0.002), AK (610 versus 814 mGy; P=0.02), DAP (4390 versus 5922.5 cGy·cm(2); P=0.02), and volume of iodinated contrast media (85 versus 116 cc; P=0.002). 3D image fusion improves the CABG detection in coronary angiography and reduces the time necessary to localize CABG, total procedure time duration, radiation exposure, and volume of contrast media. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Carbon dioxide (CO2) angiography as an option for endovascular abdominal aortic aneurysm repair (EVAR) in patients with chronic kidney disease (CKD).

    PubMed

    De Angelis, Chiara; Sardanelli, Francesco; Perego, Matteo; Alì, Marco; Casilli, Francesco; Inglese, Luigi; Mauri, Giovanni

    2017-11-01

    To assess feasibility, efficacy and safety of carbon dioxide (CO 2 ) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR) in a cohort of patients with chronic kidney disease (CKD). After Ethical Committee approval, the records of 13 patients (all male, mean age 74.6 ± 8.0 years) with CKD, who underwent EVAR to exclude an abdominal aortic aneurysm (AAA) under CO 2 angiography guidance, were reviewed. The AAA to be excluded had a mean diameter of 52.0 ± 8.0 mm. CO 2 angiography was performed by automatic (n = 7) or hand (n = 6) injection. The endograft was correctly placed and the AAA was excluded in all cases, without any surgical conversions. Two patients (15.4%) had an endoleak: one type-Ia, detected by CO 2 -DSA and effectively treated with prosthesis dilatation; one type-III, detected by CO 2 -DSA, confirmed using 10 ml of ICM, and conservatively managed. In one patient, CO 2 angiograms were considered of too low quality for guiding the procedure and 200 ml of ICM were administered. Overall, 11 patients (84.6%) underwent a successful EVAR under the guidance of the sole CO 2 angiography. No patients suffered from major complications, including those typically CO 2 -related. Two patients suffered from abdominal pain during the procedure secondary to a transient splanchnic perfusion's reduction due to CO 2 , and one patient had a worsening of renal function probably caused by a cholesterol embolization during the procedure. In patients with CKD, EVAR under CO 2 angiography guidance is feasible, effective, and safe.

  11. Informed Decision Making for Percutaneous Coronary Intervention for Stable Coronary Disease.

    PubMed

    Rothberg, Michael B; Sivalingam, Senthil K; Kleppel, Reva; Schweiger, Marc; Hu, Bo; Sepucha, Karen R

    2015-07-01

    Patients with stable coronary disease undergoing percutaneous coronary intervention (PCI) are frequently misinformed about the benefits of PCI. Little is known about the quality of decision making before angiography and possible PCI. To assess the quality of informed decision making and its association with patient decisions. We performed a cross-sectional analysis of recorded conversations between August 1, 2008, and August 31, 2012, among adults with known or suspected stable coronary disease at outpatient cardiology practices. Presence of 7 elements of informed decision making and the decision to undergo angiography and possible PCI. Of 59 conversations conducted by 23 cardiologists, 2 (3%) included all 7 elements of informed decision making; 8 (14%) met a more limited definition of procedure, alternatives, and risks. Specific elements significantly associated with not choosing angiography and possible PCI included discussion of uncertainty (odds ratio [OR], 20.5; 95% CI, 2.3-204.9), patient's role (OR, 5.3; 95% CI, 1.3-21.3), exploration of alternatives (OR, 9.5; 95% CI, 2.5-36.5), and exploration of patient preference (OR, 4.8; 95% CI, 1.2-19.4). Neither the presence of angina nor severity of symptoms was associated with choosing angiography and possible PCI. In a multivariable analysis using the total number of elements as a predictor, better informed patients were less likely to choose angiography and possible PCI (OR per additional element, 3.2; 95% CI, 1.4-7.1; P = .005). In conversations between cardiologists and patients with stable angina, informed decision making is often incomplete. More complete discussions are associated with patients choosing not to undergo angiography and possible PCI.

  12. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review.

    PubMed

    Mishra, Anuj; Ehtuish, Ehtuish F

    2006-06-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA). Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far.

  13. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    PubMed

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  14. Case Report of Bullous Pemphigoid following Fundus Fluorescein Angiography

    PubMed Central

    Demirci, Goktug; Demirci, Gulsen Tukenmez; Gulkilik, Gokhan

    2010-01-01

    Purpose To report a first case of bullous pemphigoid (BP) following intravenous fluorescein for fundus angiography. Clinical Features: A 70-year-old male patient was admitted to the intensive care unit with BP and sepsis. He reported a history of fundus fluorescein angiography with a pre-diagnosis of senile macular degeneration 2 months prior to presentation. At that time, fluorescein extravasated at the antecubital region. Following the procedure, pruritus and erythema began at the wrists bilaterally, and quickly spread to the entire body. The patient also reported a history of allergy to human albumin solution (Plamasteril®; Abbott) 15 years before, during bypass surgery. On dermatologic examination, erythematous patches were present on the scalp, chest and anogenital region. Vesicles and bullous lesions were present on upper and lower extremities. On day 2 of hospitalization, tense bullae appeared on the upper and lower extremities. The patient was treated with oral methylprednisolone 48 mg (Prednol®; Mustafa Nevzat), topical clobetasol dipropionate 0.05% cream (Dermovate®; Glaxo SmithKline), and topical 4% urea lotion (Excipial Lipo®; Orva) for presumptive bullous pemphigoid. Skin punch biopsy provided tissue for histopathology, direct immunofluorescence examination, and salt extraction, which were all consistent with BP. After 1 month, the patient was transferred to the intensive care unit with sepsis secondary to urinary tract infection; he died 2 weeks later from sepsis and cardiac failure. Conclusions To our knowledge, this is the first reported case of BP following fundus fluorescein angiography in a patient with known human albumin solution allergy. Consideration should be made to avoid fluorescein angiography, change administration route, or premedicate with antihistamines in patients with known human albumin solution allergy. The association between fundus fluorescein angiography and BP should be further investigated. PMID:20737052

  15. DETECTION OF TYPE 1 CHOROIDAL NEOVASCULAR MEMBRANES USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN TUBERCULAR POSTERIOR UVEITIS.

    PubMed

    Aggarwal, Kanika; Agarwal, Aniruddha; Sharma, Aman; Sharma, Kusum; Gupta, Vishali

    2018-04-23

    To study optical coherence tomography angiography (OCTA) and multimodal imaging features of Type 1 inflammatory choroidal neovascularization (CNV) in tubercular serpiginous-like choroiditis and response to anti-vascular endothelial growth factor therapy. In this study, multimodal imaging was performed using OCTA, enhanced-depth imaging optical coherence tomography, fluorescein angiography, and indocyanine green angiography. Correlation of OCTA with other imaging modalities in the detection of CNV was performed. The changes in CNV configuration after anti-vascular endothelial growth factor therapy were assessed. In this study, nine eyes (8 patients; 5 females; mean age: 32.5 ± 11.57 years) with diagnosis of tubercular serpiginous-like choroiditis were included. All the eyes had presence of low-lying pigment epithelial detachments on enhanced-depth imaging optical coherence tomography. Using OCTA, it was possible to detect Type 1 CNV in all eyes. Type 1 CNV networks comprised fine anastomotic network of vessels, some of which had a hairpin loop configuration. After anti-vascular endothelial growth factor therapy, there was a decrease in branching and anastomosis. The visual acuity significantly improved from 0.49 ± 0.26 (20/60 Snellen equivalent) at baseline to 0.26 ± 0.17 (20/36 Snellen equivalent) (P = 0.03) in all eyes. Type 1 CNV can occur among patients with tubercular serpiginous-like choroiditis, leading to significant visual loss even in the healed stages of the disease. Optical coherence tomography angiography can help in the detection of Type 1 CNV where conventional multimodal imaging, including fluorescein angiography and OCT, fails to make a definitive diagnosis and thereby guide the initiation of anti-vascular endothelial growth factor therapy.

  16. Sex Differences in Cardiac Medication Use Post-Catheterization in Patients Undergoing Coronary Angiography for Stable Angina with Nonobstructive Coronary Artery Disease.

    PubMed

    Galway, Shannon; Adatia, Falisha; Grubisic, Maja; Lee, May; Daniele, Patrick; Humphries, Karin H; Sedlak, Tara L

    2017-09-01

    Treatment of patients with stable angina and nonobstructive coronary artery disease (CAD) has not been well characterized. We comparatively evaluated medication use in males and females with stable angina with no CAD, nonobstructive CAD, and obstructive CAD. We studied all patients ≥20 years old with stable angina undergoing coronary angiography in British Columbia (BC), Canada, from January 2008 to March 2010 (n = 7,535). No CAD, nonobstructive CAD, and obstructive CAD were defined as 0%, 1%-49%, and ≥50% luminal narrowing in any epicardial coronary artery, respectively. Medication use, 3 months before and 3 months following angiography, was obtained through BC PharmaNet for angiotensin-converting enzyme inhibitors (ACE-I), angiotensin receptor blockers (ARBs), calcium channel blockers (CCBs), beta-blockers, statins, antiplatelet agents, and prescriptions for all three ACE-I/ARBs, beta-blockers, and statins (combination therapy). Following angiography, patients with no and nonobstructive CAD had significantly lower rates of prescription use of all medications, including combination therapy, than patients with obstructive CAD (p < 0.001). Use of ACE-I/ARBs, beta-blockers, statins, and combination therapy did not differ by sex, but females had higher use of CCB in all CAD groups, and clopidogrel in nonobstructive and obstructive CAD groups, compared to males. In patients with stable angina, medication use following angiography is low in nonobstructive CAD with only 58.9% prescribed a statin and 19.4% on combination therapy at 3 months. There are no important sex differences in medication use in any CAD category post-angiography. Future studies should explore methods of improving quality of care in patients with nonobstructive CAD.

  17. Diagnostic accuracy for macroscopic classification of nodular hepatocellular carcinoma: comparison of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging and angiography-assisted computed tomography.

    PubMed

    Tada, Toshifumi; Kumada, Takashi; Toyoda, Hidenori; Ito, Takanori; Sone, Yasuhiro; Okuda, Seiji; Ogawa, Sadanobu; Igura, Takumi; Imai, Yasuharu

    2015-01-01

    The macroscopic type of hepatocellular carcinoma (HCC) is a predictor of prognosis. We clarified the diagnostic value of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) in the macroscopic classification of nodular hepatocellular carcinoma (HCC) as compared to angiography-assisted computed tomography (CT). A total of 71 surgically resected nodular HCCs with a maximum diameter of ≤5 cm were investigated. HCCs were evaluated preoperatively using Gd-EOB-DTPA-enhanced MRI and angiography-assisted CT. HCCs were pathologically classified as simple nodular (SN), SN with extranodular growth (SN-EG), or confluent multinodular (CMN). SN-EG and CMN were grouped as non-SN. Five readers independently reviewed the images using a five-point scale. We examined the accuracy of both imaging modalities in differentiating between SN and non-SN HCC. Overall, the area under the receiver operating characteristic curve (A z ) for the diagnosis of non-SN did not differ between Gd-EOB-DTPA-enhanced MRI and angiography-assisted CT [0.879 (95% confidence interval (CI), 0.779-0.937) and 0.845 (95% CI, 0.723-0.919), respectively]. For HCCs >2 cm, the A z for Gd-EOB-DTPA-enhanced MRI was greater than 0.9. The sensitivity, specificity, and accuracy of Gd-EOB-DTPA-enhanced MRI for identifying non-SN were equal to or higher than values with angiography-assisted CT in all three categories (all tumors, ≤2 cm, and >2 cm), but the differences were not statistically significant. Using Gd-EOB-DTPA-enhanced MRI to assess the macroscopic findings in nodular HCC was equal or superior to using angiography-assisted CT.

  18. A standardized model for predicting flap failure using indocyanine green dye

    NASA Astrophysics Data System (ADS)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  19. Efficacy of oral hydration in the prevention of contrast-induced acute kidney injury in patients undergoing coronary angiography or intervention.

    PubMed

    Akyuz, Sukru; Karaca, Mehmet; Kemaloglu Oz, Tugba; Altay, Servet; Gungor, Baris; Yaylak, Baris; Yazici, Selcuk; Ozden, Kivilcim; Karakus, Gultekin; Cam, Nese

    2014-01-01

    Efficacy of intravenous (IV) volume expansion in preventing contrast-induced acute kidney injury (CI-AKI) is well known. However, the role of oral hydration has not been well established. The aim of this work was to evaluate the efficacy of oral hydration in preventing CI-AKI. We prospectively randomized 225 patients undergoing coronary angiography and/or percutaneous coronary intervention in either oral hydration or IV hydration groups. Patients who have at least one of the high-risk factors for developing CI-AKI (advanced age, type 2 diabetes mellitus, anemia, hyperuricemia, a history of cardiac failure or systolic dysfunction) were included in the study. All patients had normal renal function or stage 1-2 chronic kidney disease. Patients in the oral hydration group were encouraged to drink unrestricted amounts of fluids freely whereas isotonic saline infusion was performed by the standard protocol in the IV hydration group. CI-AKI occurred in 8/116 patients (6.9%) in the oral hydration group and 8/109 patients (7.3%) in the IV hydration group (p = 0.89). There was also no statistically significant difference between the two groups when different CI-AKI definitions were taken into account. Oral hydration is as effective as IV hydration in preventing CI-AKI in patients with normal kidney function or stage 1-2 chronic kidney disease, and who also have at least one of the other high-risk factors for developing CI-AKI. © 2014 S. Karger AG, Basel.

  20. [Radial optic neurotomy for severe central retinal vein occlusion: preliminary results].

    PubMed

    Le Rouic, J-F; Becquet, F; Zanlonghi, X; Péronnet, P; Pousset-Decré, C; Hermouet-Leclair, E; Ducournau, D

    2003-06-01

    To describe the results of radial optic neurotomy for the treatment of severe central retinal vein occlusion. Prospective noncomparative single-center study. Analysis of ten eyes of ten consecutive patients whose visual acuity was 0.1 or less. They underwent fluorescein angiography, visual field testing by automated perimetry, and macular thickness analysis by optical coherence tomography preoperatively at 3 months and at 6 months postoperatively. Mean visual acuity on an ETDRS chart increased from 30+/-12 points preoperatively to 42+/-15 points at the 3-month visit, (p=0.03), and mean macular thickness decreased from 580+/-150 micro m to 361+/-52 micro m (p=0.04). All patients had clinical improvement as determined by fundus examination and fluorescein angiography. An improvement in the central visual field was observed in all eyes. Mean visual acuity of the five patients followed-up for 6 months was 52.8+/-20 points. No visual loss was observed. None of the patients underwent laser photocoagulation or has presented with neovascularization so far. Optociliary veins developed in three eyes and a retinochoroidal anastomosis within the disk incision was observed in two eyes. These preliminary results are encouraging when compared to the reported natural progression of severe central retinal vein occlusion. A bypass of the site of occlusion is a possible mechanism for radial optic neurotomy. A randomized study should be conducted to assess the efficacy of radial optic neurotomy and determine the best candidates for surgery.

  1. The effect of arm positioning on timing and enhancement of intravenous contrast media at coronary computed tomography angiography.

    PubMed

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Nyman, Ulf; Brismar, Torkel B

    2016-09-01

    Adequate intravenous contrast media (CM) enhancement is crucial for evaluation of the coronary arteries. To compare the timing and enhancement of intravenous CM at coronary computed tomography angiography (CCTA) when positioning the arms in the traditional superior direction with that of positioning them in the ventral direction during the CM injection. One hundred patients were randomized into two groups. Group A (n = 50) had their arms positioned in the superior direction, resting on a head and arm support. Group B (n = 50) held their arms resting on the front panel of the computer tomography (CT) scanner. Scanning delay time was defined by test bolus technique. A total of 60 mL iodixanol, 320 mg/mL, was followed by a 50 mL saline flush at 6 mL/s. Cardiac output (CO) and heart rate (HR) were obtained before scanning. The attenuation was calculated by placing regions of interest (ROI) in ascending aorta, left atrium, and inferior vena cava. More patients in group A compared with group B (26 versus 14) showed a higher attenuation of the left atrium in comparison to the ascending aorta (P < 0.05). Body weight (BW) and CO were significantly related to the attenuation of ascending aorta (P < 0.01). By placing the arms in a ventral, instead of superior position the frequency of too early imaging at CCTA can be reduced. © The Foundation Acta Radiologica 2015.

  2. Murine fundus fluorescein angiography: An alternative approach using a handheld camera.

    PubMed

    Ehrenberg, Moshe; Ehrenberg, Scott; Schwob, Ouri; Benny, Ofra

    2016-07-01

    In today's modern pharmacologic approach to treating sight-threatening retinal vascular disorders, there is an increasing demand for a compact, mobile, lightweight and cost-effective fluorescein fundus camera to document the effects of antiangiogenic drugs on laser-induced choroidal neovascularization (CNV) in mice and other experimental animals. We have adapted the use of the Kowa Genesis Df Camera to perform Fundus Fluorescein Angiography (FFA) in mice. The 1 kg, 28 cm high camera has built-in barrier and exciter filters to allow digital FFA recording to a Compact Flash memory card. Furthermore, this handheld unit has a steady Indirect Lens Holder that firmly attaches to the main unit, that securely holds a 90 diopter lens in position, in order to facilitate appropriate focus and stability, for photographing the delicate central murine fundus. This easily portable fundus fluorescein camera can effectively record exceptional central retinal vascular detail in murine laser-induced CNV, while readily allowing the investigator to adjust the camera's position according to the variable head and eye movements that can randomly occur while the mouse is optimally anesthetized. This movable image recording device, with efficiencies of space, time, cost, energy and personnel, has enabled us to accurately document the alterations in the central choroidal and retinal vasculature following induction of CNV, implemented by argon-green laser photocoagulation and disruption of Bruch's Membrane, in the experimental murine model of exudative macular degeneration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Three-dimensional reconstruction of the peripancreatic vascular system based on computed tomographic angiography images and its clinical application in the surgical management of pancreatic tumors.

    PubMed

    Fang, Chi-hua; Kong, Deshuai; Wang, Xiaojun; Wang, Huaizhi; Xiang, Nan; Fan, Yingfang; Yang, Jian; Zhong, Shi Zheng

    2014-04-01

    This study aimed to investigate the clinical significance of 3-dimensional (3D) reconstruction of peripancreatic vessels for patients with suspected pancreatic cancer (PC). A total of 89 patients with PC were included; 60 patients randomly underwent computed tomographic angiography. Based on the findings of 3D reconstruction of peripancreatic vessels, the appropriate method for individualized tumor resection was determined. These patients were compared with 29 conventionally treated patients with PC. The rate of visualization was 100% for great vessels around the pancreas. The detection rates for anterior superior pancreaticoduodenal artery, posterior superior pancreaticoduodenal artery, anterior inferior pancreaticoduodenal artery, posterior inferior pancreaticoduodenal artery, dorsal pancreatic artery, superior marginal arterial branch of the pancreatic head, anterior superior pancreaticoduodenal vein, posterior superior pancreaticoduodenal vein, anterior inferior pancreaticoduodenal vein, and posterior inferior pancreaticoduodenal vein were 86.6%, 85.0%, 76.6%, 71.6%, 91.6%, 53.3%, 61.6%, 55.0%, 43.3%, and 51.6%, respectively. Forty-three patients who had undergone 3D reconstruction underwent surgery. Of the 29 conventionally treated patients, 19 underwent surgery. The operative time, blood loss, length of hospital stay, and complication incidence of the 43 patients were superior to that of the 19 patients. A peripancreatic vascular reconstruction can reveal the vascular anatomy, variations of peripancreatic vascular, and tumor-induced vascular changes; the application of the simulation surgery platform could reduce surgical trauma and decrease operative time.

  4. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    PubMed

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  5. Contrast-enhanced magnetic resonance angiography for preoperative imaging of deep inferior epigastric artery perforator flaps: advantages and disadvantages compared with computed tomography angiography: a United Kingdom perspective.

    PubMed

    Schaverien, Mark V; Ludman, Catherine N; Neil-Dwyer, Jason; McCulley, Stephen J

    2011-12-01

    The anatomy of the anterior abdominal wall is highly variable and leads to uncertainty when harvesting a deep inferior epigastric artery perforator flap. Presurgical imaging has been shown to reduce the operating time, as well as reduce the rates of flap and donor site complications. The importance of imaging of the venous system has also been recognized for reducing the risk of venous congestion. The modalities currently available for presurgical imaging include handheld Doppler ultrasound, duplex ultrasound, computed tomographic angiography (CTA), and contrast-enhanced magnetic resonance angiography (CE-MRA). Of these, the most promising are CTA and CE-MRA, and advantages and disadvantages exist for both modalities. In this article, we review the use of CE-MRA for preoperative flap imaging and report our experience with its use in deep inferior epigastric artery perforator flap harvest, as well as compare it with CTA. We also explore the future directions for presurgical flap imaging.

  6. MULTIMODAL IMAGING OF ACUTE EXUDATIVE POLYMORPHOUS VITELLIFORM MACULOPATHY WITH OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY AND ADAPTIVE OPTICS SCANNING LASER OPHTHALMOSCOPY.

    PubMed

    Skondra, Dimitra; Nesper, Peter L; Fawzi, Amani A

    2017-05-16

    To report a case of acute exudative polymorphous vitelliform maculopathy including the findings of optical coherence tomography angiography and adaptive optics scanning laser ophthalmoscopy. Findings on clinical examination, color fundus photography, spectral-domain optical coherence tomography, infrared reflectance, autofluorescence, optical coherence tomography angiography, and adaptive optics scanning laser ophthalmoscopy. A 54-year-old white man with no significant medical history and history of smoking presented with bilateral multiple serous and vitelliform detachments consistent with acute exudative polymorphous vitelliform maculopathy. Extensive infectious, inflammatory, and malignancy workup was negative. Spectral-domain optical coherence tomography showed thickened, hyperreflective ellipsoid zone, subretinal fluid, and focal as well as diffuse subretinal hyperreflective material corresponding to the vitelliform lesions. Optical coherence tomography angiography showed normal retinal and choroidal vasculature, whereas adaptive optics scanning laser ophthalmoscopy showed circular focal "target" lesions at the level of the photoreceptors in the area of foveal detachment. Multimodal imaging is valuable in evaluating patients with acute exudative polymorphous vitelliform maculopathy.

  7. Near-real-time transcutaneous vascular clipping guided by magnetic resonance angiography: a minimally invasive technique for vascular control

    NASA Astrophysics Data System (ADS)

    Ennevor, Sean J.; Castro, Dan J.; Girardi, Gino; Lufkin, Robert B.; Farahani, Keyvan; Cho, Richard C.; Soudant, Jacques

    1993-07-01

    Interstitial tumor therapy guided by imaging techniques is minimally invasive and a promising surgical approach which will become clinically practical only when effective, simple, and safe modalities for tumor excision and control of tumor vascular supply are available. In a novel experiment utilizing a 1.5 T magnetic resonance (MR) scanner, the carotid artery of a New Zealand white rabbit was identified and then clamped using the Premium Surgicliptm 9.0' disposable automatic clip applier. The magnetic resonance imager equipped with an angiography package was used to locate vasculature in the carotid triangle of the rabbit via fast scan techniques. The artery was then clamped with titanium clips, and repeat magnetic resonance angiography (MRA) clearly demonstrated the cessation of blood flow within the chosen vessel. The experimental results are promising, since the angiography package not only provided the visualization of the arterial vessel, but was also used to guide an MR compatible surgical instrument to the vessel, with no artifact seen.

  8. Occult Mediastinal Great Vessel Trauma: The Value of Aortography Performed During Angiographic Screening for Blunt Cervical Vascular Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Charles E.; Bauer, Jason R.; Cothren, C. Clay

    2005-05-15

    Purpose. To determine the value of aortography in the assessment of occult aortic and great vessel injuries when routinely performed during screening angiography for blunt cerebrovascular injury (BCVI). Methods. One hundred and one consecutive patients who received both aortography and screening four-vessel angiography over 4 years were identified retrospectively. Angiograms for these patients were evaluated, and the incidence of occult mediastinal vascular injury was determined. Results. Of the 101 patients, 6 (6%) had angiographically documented traumatic aortic injuries. Of these 6 patients, one injury (17%) was unsuspected prior to angiography. Four of the 6 (67%) also had BCVI. One additionalmore » patient also had an injury to a branch of the subclavian artery. Conclusion. Routine aortography during screening angiography for BCVI is not warranted due to the low incidence (1%) of occult mediastinal arterial injury. However, in the setting of a BCVI screening study and no CT scan of the chest, aortography may be advantageous.« less

  9. Cost-effectiveness of 64-slice CT angiography compared to conventional coronary angiography based on a coverage with evidence development study in Ontario.

    PubMed

    Goeree, Ron; Blackhouse, Gord; Bowen, James M; O'Reilly, Daria; Sutherland, Simone; Hopkins, Robert; Chow, Benjamin; Freeman, Michael; Provost, Yves; Dennie, Carole; Cohen, Eric; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan; Paul, Narinder; Parker, John D

    2013-10-01

    Conventional coronary angiography (CCA) is the standard diagnostic for coronary artery disease (CAD), but multi-detector computed tomography coronary angiography (CTCA) is a non-invasive alternative. A multi-center coverage with evidence development study was undertaken and combined with an economic model to estimate the cost-effectiveness of CTCA followed by CCA vs CCA alone. Alternative assumptions were tested in patient scenario and sensitivity analyses. CCA was found to dominate CTCA, however, CTCA was relatively more cost-effective in females, in advancing age, in patients with lower pre-test probabilities of CAD, the higher the sensitivity of CTCA and the lower the probability of undergoing a confirmatory CCA following a positive CTCA. RESULTS were very sensitive to alternative patient populations and modeling assumptions. Careful consideration of patient characteristics, procedures to improve the diagnostic yield of CTCA and selective use of CCA following CTCA will impact whether CTCA is cost-effective or dominates CCA.

  10. Fusion of magnetic resonance angiography and magnetic resonance imaging for surgical planning for meningioma--technical note.

    PubMed

    Kashimura, Hiroshi; Ogasawara, Kuniaki; Arai, Hiroshi; Beppu, Takaaki; Inoue, Takashi; Takahashi, Tsutomu; Matsuda, Koichi; Takahashi, Yujiro; Fujiwara, Shunrou; Ogawa, Akira

    2008-09-01

    A fusion technique for magnetic resonance (MR) angiography and MR imaging was developed to help assess the peritumoral angioarchitecture during surgical planning for meningioma. Three-dimensional time-of-flight (3D-TOF) and 3D-spoiled gradient recalled (SPGR) datasets were obtained from 10 patients with intracranial meningioma, and fused using newly developed volume registration and visualization software. Maximum intensity projection (MIP) images from 3D-TOF MR angiography and axial SPGR MR imaging were displayed at the same time on the monitor. Selecting a vessel on the real-time MIP image indicated the corresponding points on the axial image automatically. Fusion images showed displacement of the anterior cerebral or middle cerebral artery in 7 patients and encasement of the anterior cerebral arteries in 1 patient, with no relationship between the main arterial trunk and tumor in 2 patients. Fusion of MR angiography and MR imaging can clarify relationships between the intracranial vasculature and meningioma, and may be helpful for surgical planning for meningioma.

  11. Safety, efficacy, and cost of intraoperative indocyanine green angiography compared to intraoperative catheter angiography in cerebral aneurysm surgery.

    PubMed

    Hardesty, Douglas A; Thind, Harjot; Zabramski, Joseph M; Spetzler, Robert F; Nakaji, Peter

    2014-08-01

    Intraoperative angiography in cerebrovascular neurosurgery can drive the repositioning or addition of aneurysm clips. Our institution has switched from a strategy of intraoperative digital subtraction angiography (DSA) universally, to a strategy of indocyanine green (ICG) videoangiography with DSA on an as-needed basis. We retrospectively evaluated whether the rates of perioperative stroke, unexpected postoperative aneurysm residual, or parent vessel stenosis differed in 100 patients from each era (2002, "DSA era"; 2007, "ICG era"). The clip repositioning rate for neck residual or parent vessel stenosis did not differ significantly between the two eras. There were no differences in the rate of perioperative stroke or rate of false-negative studies. The per-patient cost of intraoperative imaging within the DSA era was significantly higher than in the ICG era. The replacement of routine intraoperative DSA with ICG videoangiography and selective intraoperative DSA in cerebrovascular aneurysm surgery is safe and effective. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Characterization of normal feline renal vascular anatomy with dual-phase CT angiography.

    PubMed

    Cáceres, Ana V; Zwingenberger, Allison L; Aronson, Lillian R; Mai, Wilfried

    2008-01-01

    Helical computed tomography angiography was used to evaluate the renal vascular anatomy of potential feline renal donors. One hundred and fourteen computed tomography angiograms were reviewed. The vessels were characterized as single without bifurcation, single with bifurcation, double, or triple. Multiplicity was most commonly seen for the right renal vein (45/114 vs. 3/114 multiple left renal veins, 0/114 multiple right renal arteries, and 8/114 multiple left renal arteries). The right kidney was 13.3 times more likely than the left to have multiple renal veins. Additional vascular variants included double caudal vena cava and an accessory renal artery. For the left kidney, surgery and computed tomography angiography findings were in agreement in 92% of 74 cats. For the right kidney, surgery and computed tomography angiography findings were in agreement in 6/6 cats. Our findings of renal vascular anatomy variations in cats were similar to previous reports in humans. Identifying and recognizing the pattern of distribution of these vessels is important when performing renal transplantation.

  13. Image quality improvement in three-dimensional time-of-flight magnetic resonance angiography using the subtraction method for brain and temporal bone diseases.

    PubMed

    Peng, Shu-Hui; Shen, Chao-Yu; Wu, Ming-Chi; Lin, Yue-Der; Huang, Chun-Huang; Kang, Ruei-Jin; Tyan, Yeu-Sheng; Tsao, Teng-Fu

    2013-08-01

    Time-of-flight (TOF) magnetic resonance (MR) angiography is based on flow-related enhancement using the T1-weighted spoiled gradient echo, or the fast low-angle shot gradient echo sequence. However, materials with short T1 relaxation times may show hyperintensity signals and contaminate the TOF images. The objective of our study was to determine whether subtraction three-dimensional (3D) TOF MR angiography improves image quality in brain and temporal bone diseases with unwanted contaminations with short T1 relaxation times. During the 12-month study period, patients who had masses with short T1 relaxation times noted on precontrast T1-weighted brain MR images and 24 healthy volunteers were scanned using conventional and subtraction 3D TOF MR angiography. The qualitative evaluation of each MR angiogram was based on signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and scores in three categories, namely, (1) presence of misregistration artifacts, (2) ability to display arterial anatomy selectively (without contamination by materials with short T1 relaxation times), and (3) arterial flow-related enhancement. We included 12 patients with intracranial hematomas, brain tumors, or middle-ear cholesterol granulomas. Subtraction 3D TOF MR angiography yielded higher CNRs between the area of the basilar artery (BA) and normal-appearing parenchyma of the brain and lower SNRs in the area of the BA compared with the conventional technique (147.7 ± 77.6 vs. 130.6 ± 54.2, p < 0.003 and 162.5 ± 79.9 vs. 194.3 ± 62.3, p < 0.001, respectively) in all 36 cases. The 3D subtraction angiography did not deteriorate image quality with misregistration artifacts and showed a better selective display of arteries (p < 0.0001) and arterial flow-related enhancement (p < 0.044) than the conventional method. Subtraction 3D TOF MR angiography is more appropriate than the conventional method in improving the image quality in brain and temporal bone diseases with unwanted contaminations with short T1 relaxation times. Copyright © 2013. Published by Elsevier B.V.

  14. Assessment of incomplete clipping of aneurysms intraoperatively by a near-infrared indocyanine green-video angiography (Niicg-Va) integrated microscope.

    PubMed

    Imizu, S; Kato, Y; Sangli, A; Oguri, D; Sano, H

    2008-08-01

    The objective of this article was to assess the clinical use and the completeness of clipping with total occlusion of the aneurysmal lumen, real-time assessment of vascular patency in the parent, branching and perforating vessels, intraoperative assessment of blood flow, image quality, spatial resolution and clinical value in difficult aneurysms using near infrared indocyanine green video angiography integrated on to an operative Pentero neurosurgical microscope (Carl Zeiss, Oberkochen Germany). Thirteen patients with aneurysms were operated upon. An infrared camera with near infrared technology was adapted on to the OPMI Pentero microscope with a special filter and infrared excitation light to illuminate the operating field which was designed to allow passage of the near infrared light required for excitation of indocyanine green (ICG) which was used as the intravascular marker. The intravascular fluorescence was imaged with a video camera attached to the microscope. ICG fluorescence (700-850 nm) from a modified microscope light source on to the surgical field and passage of ICG fluorescence (780-950 nm) from the surgical field, back into the optical path of the microscope was used to detect the completeness of aneurysmal clipping Incomplete clipping in three patients (1 female and 2 males) with unruptured complicated aneurysms was detected using indocyanine green video angiography. There were no adverse effects after injection of indocyanine green. The completeness of clipping was inadequately detected by Doppler ultrasound miniprobe and rigid endoscopy and was thus complemented by indocyanine green video angiography. The operative microscope-integrated ICG video angiography as a new intraoperative method for detecting vascular flow, was found to be quick, reliable, cost-effective and possibly a substitute or adjunct for Doppler ultrasonography or intraoperative DSA, which is presently the gold standard. The simplicity of the method, the speed with which the investigation can be performed, the quality of the images, and the outcome of surgical procedures have all reduced the need for angiography. This technique may be useful during routine aneurysm surgery as an independent form of angiography and/or as an adjunct to intraoperative or postoperative DSA.

  15. [3D-TOF MR-angiography with high spatial resolution for surgical planning in insular lobe gliomas].

    PubMed

    Bykanov, A E; Pitskhelauri, D I; Pronin, I N; Tonoyan, A S; Kornienko, V N; Zakharova, N E; Turkin, A M; Sanikidze, A Z; Shkarubo, M A; Shkatova, A M; Shults, E I

    2015-01-01

    Despite the obvious progress in modern neurosurgery, surgery for glial tumors of the insular lobe is often associated with a high risk of postoperative neurological deficit, which is primarily caused by damage to perforating arteries of the M1 segment of the middle cerebral artery. The work is aimed at evaluating the effectiveness of high resolution time-of-flight (3D-TOF) MR angiography in imaging of medial and lateral lenticulostriate arteries and determining their relationship to tumor edge in patients with gliomas of the insula. 3D-TOF MR angiography data were analyzed in 20 patients with primarily diagnosed cerebral gliomas involving the insula. All patients underwent non-contrast enhanced 3D-TOF MR angiography. In 6 cases, 3D-TOF MRA was performed before and after contrast enhancement. 3D-TOF angiography before intravenous contrast injection was capable of visualizing the medial lenticulostriate arteries in 19 patients (95% of all cases) and lateral lenticulostriate arteries in 18 patients (90% of all cases). Contrast-enhanced 3D-TOF angiography allows for better visualization of both the proximal and distal segments of lenticulostriate arteries. Three variants of relationship between the tumor and lenticulostriate arteries were identified. Variant I: the tumor grew over the arteries without their displacement in 2 cases (10% of the total number of observations); variant II: the tumor caused medial displacement of arteries without growing over them in 11 cases (55% of the total number of observations); variant III: the tumor partially grew over and displaced arteries in 2 cases (10%). In 25% of cases (5 patients), tumor was poorly visualized on 3D-TOF MR angiograms because their signal characteristics did not differ from those of the medulla (tumor tissue was T1 isointense). As a result, it was impossible to determine the relationship between the tumor and lenticulostriate arteries. High spatial resolution time-of-flight MR angiography can be recommended for preoperative imaging of lenticulostriate arteries to plan the extent of neurosurgical resection in patients with glial tumors of the insular lobe.

  16. Extremely long posterior communicating artery diagnosed by MR angiography: report of two cases.

    PubMed

    Uchino, Akira; Suzuki, Chihiro; Tanaka, Masahiko

    2015-07-01

    We report two cases of an extremely long left posterior communicating artery (PCoA) diagnosed by magnetic resonance (MR) angiography. The PCoA arose from the normal point of the supraclinoid internal carotid artery and fused with the posterior cerebral artery (PCA) at its posterior ambient segment, forming an extremely long PCoA and extremely long precommunicating segment of the PCA. To our knowledge, this is the first report of such variation. Careful observation of MR angiographic images is important for detecting rare arterial variations. To identify these anomalous arteries on MR angiography, partial maximum-intensity-projection images are useful.

  17. Correction of rotational distortion for catheter-based en face OCT and OCT angiography

    PubMed Central

    Ahsen, Osman O.; Lee, Hsiang-Chieh; Giacomelli, Michael G.; Wang, Zhao; Liang, Kaicheng; Tsai, Tsung-Han; Potsaid, Benjamin; Mashimo, Hiroshi; Fujimoto, James G.

    2015-01-01

    We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. PMID:25361133

  18. Fluorescein and Indocyanine Green Angiography for Uveitis

    PubMed Central

    Herbort, Carl P

    2009-01-01

    In recent years enormous progress has been achieved in investigational procedures for uveitis. Imaging is one such example with the advent of new methods such as indocyanine green angiography, ultrasound biomicroscopy and optical coherence tomography to cite only the most important. This tremendous increase in precision and accuracy in the assessment of the level and degree of inflammation and its monitoring comes in parallel with the development of extremely potent and efficacious therapies. In view of these developments, our whole attitude in the appraisal and investigation of the uveitis patient has to be adapted and correctly reoriented integrating the recent developments and this is no different for ocular angiography. PMID:20404985

  19. Ultra-widefield fluorescein angiography reveals retinal phlebitis in Susac's syndrome.

    PubMed

    Klufas, Michael A; Dinkin, Marc J; Bhaleeya, Swetangi D; Chapman, Kristin O; Riley, Claire S; Kiss, Szilárd

    2014-01-01

    A 23-year-old woman with history of headaches and auditory changes presented with acute-onset visual field loss in the right eye. The combination of multiple retinal branch artery occlusions of the right eye on funduscopic examination, characteristic white matter lesions in the corpus callosum on magnetic resonance imaging, and hearing loss on audiometric testing led to a diagnosis of Susac's syndrome. Ultra-widefield fluorescein angiography revealed involvement of the retinal veins, which has not been previously reported with this condition. Additionally, ultra-widefield indocyanine green angiography demonstrated changes in the choroidal circulation, which are controversial in this syndrome. Copyright 2014, SLACK Incorporated.

  20. The significance of fluorescein angiography in the early diagnosis of lesions on ocular fundus at pseudoxanthoma elasticum patients.

    PubMed

    Bogdanowski, T; Gluza, J; Rasiewicz, D

    1977-05-27

    The role of fluorescein angiography in early diagnosis of lesions on fundus of the eye at pseudoxanthoma elasticum patients has been shown. The authors show angiographic changes on the basis of three cases of pseudoxanthoma elasticum patients.

  1. Quantitative contrast enhanced magnetic resonance imaging for the evaluation of peripheral arterial disease: a comparative study versus standard digital angiography.

    PubMed

    Pavlovic, Chris; Futamatsu, Hideki; Angiolillo, Dominick J; Guzman, Luis A; Wilke, Norbert; Siragusa, Daniel; Wludyka, Peter; Percy, Robert; Northrup, Martin; Bass, Theodore A; Costa, Marco A

    2007-04-01

    The purpose of this study is to evaluate the accuracy of semiautomated analysis of contrast enhanced magnetic resonance angiography (MRA) in patients who have undergone standard angiographic evaluation for peripheral vascular disease (PVD). Magnetic resonance angiography is an important tool for evaluating PVD. Although this technique is both safe and noninvasive, the accuracy and reproducibility of quantitative measurements of disease severity using MRA in the clinical setting have not been fully investigated. 43 lesions in 13 patients who underwent both MRA and digital subtraction angiography (DSA) of iliac and common femoral arteries within 6 months were analyzed using quantitative magnetic resonance angiography (QMRA) and quantitative vascular analysis (QVA). Analysis was repeated by a second operator and by the same operator in approximately 1 month time. QMRA underestimated percent diameter stenosis (%DS) compared to measurements made with QVA by 2.47%. Limits of agreement between the two methods were +/- 9.14%. Interobserver variability in measurements of %DS were +/- 12.58% for QMRA and +/- 10.04% for QVA. Intraobserver variability of %DS for QMRA was +/- 4.6% and for QVA was +/- 8.46%. QMRA displays a high level of agreement to QVA when used to determine stenosis severity in iliac and common femoral arteries. Similar levels of interobserver and intraobserver variability are present with each method. Overall, QMRA represents a useful method to quantify severity of PVD.

  2. [Embolic complications by ink clots removed from syringes during cerebral angiography].

    PubMed

    Kohyama, Shinya; Ishihara, Shoichiro; Yamane, Fumitaka; Ishihara, Hideaki; Kanazawa, Ryuzaburo; Suzuki, Masanori; Neki, Hiroaki; Ohkawara, Mai

    2009-01-01

    We noted, during cerebral angiography, that the contrast medium was contaminated with numerous small black ink clots from gradation marks on syringes. In this report, we show that ink can be removed from syringes in solid form, and that they may result in embolic complications during cerebral angiography. To demonstrate that the ink from gradation marks on syringes can come off in a solid form and attach itself to the gloves during cerebral angiography, syringes were gripped many times (just as in an angiographic procedure) after immersion in contrast medium or 0.9% saline for 10 minutes. To see if difference of contrast medium and syringes could affect the removing of ink, five types of nonangiographic syringes and one type of angiographic syringe were rubbed with gauze after certain time periods after immersing them in four kinds of contrast medium or 0.9% saline. Ink attached itself to the gloves in a solid form by repeated gripping due to adherence of contrast medium. Ink was removed from all nonangiographic syringes by rubbing after immersion in any type of contrast medium for two hours. Gradation marks on angiographic syringes were stable with all types of contrast medium. Thus, ink for gradation marks on nonangiographic syringes, which is easily removed in a solid form due to contrast medium, can be the source of embolic complication during cerebral angiography.

  3. Using decision trees for measuring gender equity in the timing of angiography in patients with acute coronary syndrome: a novel approach to equity analysis.

    PubMed

    Bierman, Arlene S; Brown, Adalsteinn D; Levinton, Carey M

    2015-12-23

    Methods to measure or quantify equity in health care remain scarce, if not difficult to interpret. A novel method to measure health equity is presented, applied to gender health equity, and illustrated with an example of timing of angiography in patients following a hospital admission for an acute coronary syndrome. Linked administrative hospital discharge and survey data was used to identify a retrospective cohort of patients hospitalized with Acute Coronary Syndrome (ACS) between 2002 and 2008 who also responded to the Canadian Community Health Survey (CCHS), was analyzed using decision trees to determine whether gender impacted the delay to angiography following an ACS. Defining a delay to angiography as 1 day or more, resulted in a non-significant difference in an equity score of 0.14 for women and 0.12 for men, where 0 and 1 represents perfect equity and inequity respectively. Using 2 and 3 day delays as a secondary outcome resulted in women and men producing scores of 0.19 and 0.17 for a 2 day delay and 0.22 and 0.23 for a 3 day delay. A technique developed expressly for measuring equity suggests that men and women in Ontario receive equitable care in access to angiography with respect to timeliness following an ACS.

  4. Comparison of computed tomography pulmonary angiography and point-of-care tests for pulmonary thromboembolism diagnosis in dogs.

    PubMed

    Goggs, R; Chan, D L; Benigni, L; Hirst, C; Kellett-Gregory, L; Fuentes, V L

    2014-04-01

    To evaluate the feasibility of CT pulmonary angiography for identification of naturally occurring pulmonary thromboembolism in dogs using predefined diagnostic criteria and to assess the ability of echocardiography, cardiac troponins, D-dimers and kaolin-activated thromboelastography to predict the presence of pulmonary thromboembolism in dogs. Twelve dogs with immune-mediated haemolytic anaemia and evidence of respiratory distress were prospectively evaluated. Dogs were sedated immediately before CT pulmonary angiography using intravenous butorphanol. Spiral CT pulmonary angiography was performed with a 16 detector-row CT scanner using a pressure injector to infuse contrast media through peripheral intravenous catheters. Pulmonary thromboembolism was diagnosed using predefined criteria. Contemporaneous tests included echocardiography, arterial blood gas analysis, kaolin-activated thromboelastography, D-dimers and cardiac troponins. Based on predefined criteria, four dogs were classified as pulmonary thromboembolism positive, three dogs were suspected to have pulmonary thromboembolism and the remaining five dogs had negative scans. The four dogs identified with pulmonary thromboembolism all had discrete filling defects in main or lobar pulmonary arteries. None of the contemporaneous tests was discriminant for pulmonary thromboembolism diagnosis, although the small sample size was limiting. CT pulmonary angiography can be successfully performed in dogs under sedation, even in at-risk patients with respiratory distress and can both confirm and rule out pulmonary thromboembolism in dogs. © 2014 British Small Animal Veterinary Association.

  5. Management of a case with misdiagnosed spinal dural arterio-venous fistula.

    PubMed

    Lien, Chia-Yi; Lui, Chun-Chung; Lu, Cheng-Hsien; Chang, Wen-Neng

    2014-03-01

    Spinal dural arterio-venous fistula (SDAVF) is an uncommon and easily misdiagnosed vascular malformation. We aimed to report the diagnosis and management of a case with SDAVF. A 62-year-old man suffered from acute paraparesis about 15 months before this study. He underwent a neurosurgical procedure for herniated discs of the cervical spine at that time but there was no relief and the symptoms worsened despite the surgery. Neurologically, he had spastic paraparesis and decreased vibration sensation of the lower limbs. Spinal magnetic resonance imaging (MRI) revealed intra-medullary hyper-intensity lesion at T8 to T10 levels and tubular-like signal void structures in the corresponding posterior sub-arachnoid space. Further trans-arterial angiography through right T6 intercostal artery catheterization revealed engorged veins, thereby confirming the diagnosis of SDAVF. The patient was treated via endovascular embolization (18% Onyx, EV3TM MIT, Bonn, Germany) through spinal angiography and the results showed a marked decrease in engorged veins. After a 4-month follow-up, the patient was symptomatic but stable. Follow-up MRI showed a complete disappearance of the hyper-intensity change of the spinal cord. Spinal MR angiography did not reveal any recurrence of SDAVF. This case study demonstrated the easily misdiagnosed state of SDAVF. Serial neuroimage studies including spinal MRI, endovascular embolization through spinal angiography and MR angiography can be useful tools for its diagnostic confirmation, management and follow-up study.

  6. POLYPOIDAL CHOROIDAL VASCULOPATHY SECONDARY TO A STABLE CHOROIDAL NEVUS.

    PubMed

    Wong, James G; Lai, Xin Jie; Sarafian, Richard Y; Wong, Hon Seng; Smith, Jeremy B

    2016-01-01

    Choroidal nevus is the most common ocular fundus tumor in adults. Previous studies have widely discussed the features of choroidal neovascularization secondary to nevus and its treatment options. Polypoidal choroidal vasculopathy (PCV) is an exudative chorioretinopathy that is often underdiagnosed. Clinical features, natural history, and treatment response of PCV are distinct from occult choroidal neovascularization. Polypoidal choroidal vasculopathy secondary to choroidal nevus has not been previously documented. We report a patient with a history of stable choroidal nevus who developed a polypoidal lesion at the edge of the nevus lesion. A white woman who presented with a choroidal nevus and clinical features of PCV was examined using fundoscopy, optical coherence tomography, fluorescein angiography, and indocyanine green angiography. A polypoidal lesion with an associated branching vascular network adjacent to the nevus was demonstrated by optical coherence tomography, fluorescein angiography, and indocyanine green angiography. The patient was asymptomatic and was managed conservatively. Our case showed that PCV developing in association with a stable choroidal nevus. Pathogenic mechanisms of this condition may include chronic degenerative or inflammatory changes at the level of the retinal pigment epithelium resulting in vascular changes. Unlike treatment of occult choroidal neovascularization secondary to nevus, optimal management of PCV secondary to nevus may vary. Indocyanine green angiography is the gold standard for the diagnosis of PCV and is a useful investigation in atypical choroidal neovascularization.

  7. TOWARD QUANTITATIVE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY: Visualizing Blood Flow Speeds in Ocular Pathology Using Variable Interscan Time Analysis.

    PubMed

    Ploner, Stefan B; Moult, Eric M; Choi, WooJhon; Waheed, Nadia K; Lee, ByungKun; Novais, Eduardo A; Cole, Emily D; Potsaid, Benjamin; Husvogt, Lennart; Schottenhamml, Julia; Maier, Andreas; Rosenfeld, Philip J; Duker, Jay S; Hornegger, Joachim; Fujimoto, James G

    2016-12-01

    Currently available optical coherence tomography angiography systems provide information about blood flux but only limited information about blood flow speed. The authors develop a method for mapping the previously proposed variable interscan time analysis (VISTA) algorithm into a color display that encodes relative blood flow speed. Optical coherence tomography angiography was performed with a 1,050 nm, 400 kHz A-scan rate, swept source optical coherence tomography system using a 5 repeated B-scan protocol. Variable interscan time analysis was used to compute the optical coherence tomography angiography signal from B-scan pairs having 1.5 millisecond and 3.0 milliseconds interscan times. The resulting VISTA data were then mapped to a color space for display. The authors evaluated the VISTA visualization algorithm in normal eyes (n = 2), nonproliferative diabetic retinopathy eyes (n = 6), proliferative diabetic retinopathy eyes (n = 3), geographic atrophy eyes (n = 4), and exudative age-related macular degeneration eyes (n = 2). All eyes showed blood flow speed variations, and all eyes with pathology showed abnormal blood flow speeds compared with controls. The authors developed a novel method for mapping VISTA into a color display, allowing visualization of relative blood flow speeds. The method was found useful, in a small case series, for visualizing blood flow speeds in a variety of ocular diseases and serves as a step toward quantitative optical coherence tomography angiography.

  8. Feasibility and clinical utility of ultra-widefield indocyanine green angiography.

    PubMed

    Klufas, Michael A; Yannuzzi, Nicolas A; Pang, Claudine E; Srinivas, Sowmya; Sadda, Srinivas R; Freund, K Bailey; Kiss, Szilárd

    2015-03-01

    To evaluate the feasibility and clinical utility of a novel noncontact scanning laser ophthalmoscope-based ultra-widefield indocyanine green angiographic system. Ultra-widefield indocyanine green angiographic images were captured using a modified Optos P200Tx that produced high-resolution images of the choroidal vasculature with up to a 200° field. Ultra-widefield indocyanine green angiography was performed on patients with a variety of retinal conditions to assess utility of this imaging technique for diagnostic purposes and disease treatment monitoring. Ultra-widefield indocyanine green angiography was performed on 138 eyes of 69 patients. Mean age was 58 ± 16.9 years (range, 24-85 years). The most common ocular pathologies imaged included central serous chorioretinopathy (24 eyes), uveitis (various subtypes, 16 eyes), age-related macular degeneration (12 eyes), and polypoidal choroidal vasculopathy (4 eyes). In all eyes evaluated with ultra-widefield indocyanine green angiography, high-resolution images of choroidal and retinal circulation were obtained with sufficient detail out to 200° of the fundus. In this series of 138 eyes, scanning laser ophthalmoscope-based ultra-widefield indocyanine green angiography was clinically practical and provided detailed images of both the central and peripheral choroidal circulation. Future studies are needed to refine the clinical value of this imaging modality and the significance of peripheral choroidal vascular changes in the diagnosis, monitoring, and treatment of ocular diseases.

  9. Optical Coherence Tomography Angiography versus Dye Angiography in Age-Related Macular Degeneration: Sensitivity and Specificity Analysis.

    PubMed

    Nikolopoulou, Eleni; Lorusso, Massimo; Micelli Ferrari, Luisa; Cicinelli, Maria Vittoria; Bandello, Francesco; Querques, Giuseppe; Micelli Ferrari, Tommaso

    2018-01-01

    Optical coherence tomography angiography (OCTA) could be a valid tool to detect choroidal neovascularization (CNV) in neovascular age-related macular degeneration (nAMD), allowing the analysis of the type, the morphology, and the extension of CNV in most of the cases. To determine the sensitivity and specificity of OCTA in detecting CNV secondary to nAMD, compared to fluorescein angiography (FA) and indocyanine green angiography (ICGA). Prospective observational study. Patients with suspected nAMD were recruited between May and December 2016. Patients underwent FA, ICGA, spectral domain OCT, and OCTA (AngioVue, Optovue, Inc.). Sensitivity and specificity of FA, with or without ICGA, were assessed and compared with OCTA. Seventy eyes of 70 consecutive patients were included: 32 eyes (45.7%) with type I CNV, 8 eyes (11.4%) with type II CNV, 4 eyes (5.7%) with type III CNV, 6 eyes (8.6%) with mixed type I and type II CNV, and 20 eyes (28.6%) with no CNV. Sensitivity of OCTA was 88% and specificity was 90%. Concordance between FA/ICGA and OCTA was very good (0,91; range 0,81-1,00). OCTA showed high sensitivity and specificity for detection of CNV. Concordance between OCTA and gold-standard dye-based techniques was excellent. OCTA may represent a first-line noninvasive method for the diagnosis of nAMD.

  10. Cost identification of abdominal aortic aneurysm imaging by using time and motion analyses.

    PubMed

    Rubin, G D; Armerding, M D; Dake, M D; Napel, S

    2000-04-01

    To compare the costs of performing helical computed tomographic (CT) angiography with three-dimensional rendering versus intraarterial digital subtraction angiography (DSA) for preoperative imaging of abdominal aortic aneurysms (AAAs). A single observer determined the variable direct costs of performing nine intraarterial DSA and 10 CT angiographic examinations in age- and general health-matched patients with AAA by using time and motion analyses. All personnel directly involved in the cases were tracked, and the involvement times were recorded to the nearest minute. All material items used during the procedures were recorded. The cost of labor was determined from personnel reimbursement data, and the cost of materials, from vendor pricing. The variable direct costs of laboratory tests and using the ambulatory treatment unit for postprocedural monitoring, as well as all fixed direct costs, were assessed from hospital accounting records. The total costs were determined for each procedure and compared by using the Student t test and calculating the CIs. The mean total direct cost of intraarterial DSA (+/- SD) was $1,052 +/- 71, and that of CT angiography was $300 +/- 30, which are significantly different (P < 4.1 x 10(-11)). With 95% confidence, intraarterial DSA cost 3.2-3.7 times more than CT angiography for the assessment of AAA. Assuming equal diagnostic utility and procedure-related morbidity, institutions may have substantial cost savings whenever CT angiography can replace intraarterial DSA for imaging AAAs.

  11. [3-D angiography in diagnosis and treatment of intracranial aneurysm].

    PubMed

    Wang, D; Ling, F; Liu, S

    2001-09-01

    To summarize the results of initial application of three-dimensional angiography (3D-Angio) in diagnosis and treatment of intracranial aneurysms. From August 1999 to January 2001, standard digital subtraction angiography (two-dimensional angiography, 2D-Angio) and 3D-Angio(obtained by reconstruction of rotational angiography) were performed in 65 patients with confirmed or suspected aneurysms. Sixty-six aneurysms were found in 60 patients and nothing was found in 5. Of 66 the aneurysms (60 cases), 46 (43 cases) were treated by intrasaccule embolizotion with coils, 3 (3 cases) by occluding the parent artery with detachable balloon, 10 (10 cases) by surgery, and 1 (1 case) by combination of extracranial-intracranial bypass and balloon occlusion of parent artery. Six (3 cases) were not treated. Two aneurysms that could not be detected by 2D-Angio were diagnosed by 3D-Angio. Three aneurysms that were difficult or dangerous to embolize by 2D-Angio were embolized successfully with the help of 3D-Angio. Three aneurysms seemed to be embolized on 2D-Angio were proved impossible to be embolized on 3D-Angio. Of the 46 aneurysms embolized intrasaccularly, 38(82.6%) were completely embolized on 2D-Angio. In the 38, 8 had residual aneurysm on 3D-Angio. More accurate diagnosis and secure treatment of intracranial aneurysm can be reached by 3D-Angio.

  12. Assessment of an introductory cervicocerebral catheter angiography learning program: a pilot study.

    PubMed

    Lui, Y W; Farinhas, J M; Basalely, A M; Hsu, K A; Freeman, K; Bello, J A

    2012-06-01

    There is no standardized curriculum currently available at most institutions for establishing procedural competency in trainees performing cervicocerebral angiography. The purpose of this study was to evaluate a simple learning program to supplement the teaching of basic cervicocerebral angiography. An 11-session interactive curriculum was implemented covering anatomic, clinical, and radiographic topics for the novice cervicocerebral angiographer. The target learner was the neuroradiology fellow. Data were gathered regarding fellow comfort level on topics relating to cervicocerebral angiography by using a 5-point Likert scale. Improvement in scores on knowledge-based questions after completion of the curriculum was calculated (McNemar test). Trainee-perceived utility of the program was also recorded by using a 5-point Likert scale. Focus sessions were held at the completion of the curriculum to gather feedback regarding the strengths and weaknesses of the program from participants. Ten subjects were enrolled in this pilot study for 3 years. Topics where participants reported a poor initial comfort level (4 or higher) included selection of injection rates and volumes and reformation of reverse-curve catheters. Trainees demonstrated a statistically significant change in the distribution of scores of 29.3% (49.4%-78.7% correct response rate, P < .0001). The average perceived utility was 1.5 (1 = most useful, 5 = least useful). This simple learning program was a useful adjunct to the training of fellows in diagnostic cervicocerebral angiography, resulting in quantitative improvements in knowledge.

  13. Evaluation of the anterior ethmoidal artery by 3D dual volume rotational digital subtraction angiography and native multidetector CT with multiplanar reformations. Initial findings.

    PubMed

    Pandolfo, Ignazio; Vinci, Sergio; Salamone, Ignazio; Granata, Francesca; Mazziotti, Silvio

    2007-06-01

    Our purpose is to codify the anterior ethmoidal artery (AEA) course and its relationship with adjacent structures. Twenty patients with cerebrovascular disease underwent selective internal carotid dual volume angiography. Fusion of the vascular and bony images was obtained successively on a second console. MDCT of the cranium was performed in all patients. To identify the AEA course, multiplanar CT reformations were obtained. In all cases the entry-point of AEA and its course were identified by means of dual volume angiography. The information was confirmed by MDCT. In a second phase, we studied another 78 patients affected by inflammatory disease and polyposis only by means of MDCT, in order to confirm the previous data obtained by comparison between angiography and MDCT. In this second phase, 110/156 vessels were indirectly detected by means of visualization of the ethmoidal entry point. In the remaining cases, AEA was directly shown due to integrity of the thin ethmoidal bone lamellae or bony canal. Dual volume angiography is essential to identify the course of the AEA (standard of reference for the interpretation of CT). In patients with benign rhinosinusal pathology, where invasivity techniques are not justified, MPR reconstructions were of pivotal importance in the evaluation of the course of the artery with particular reference to its relationship with the frontal recess.

  14. Intravascular Ultrasound to Guide Percutaneous Coronary Interventions

    PubMed Central

    2006-01-01

    Executive Summary Objective The objective of this health technology policy assessment was to determine the effectiveness and cost-effectiveness of using intravascular ultrasound (IVUS) as an adjunctive imaging tool to coronary angiography for guiding percutaneous coronary interventions. Background Intravascular Ultrasound Intravascular ultrasound is a procedure that uses high frequency sound waves to acquire 3-dimensional images from the lumen of a blood vessel. The equipment for performing IVUS consists of a percutaneous transducer catheter and a console for reconstructing images. IVUS has been used to study the structure of the arterial wall and nature of atherosclerotic plaques, and obtain measurements of the vessel lumen. Its role in guiding stent placement is also being investigated. IVUS is presently not an insured health service in Ontario. Clinical Need Coronary artery disease accounts for approximately 55% of cardiovascular deaths, the leading cause of death in Canada. In Ontario, the annual mortality rate due to ischemic heart disease was 141.8 per 100,000 population between 1995 and 1997. Percutaneous coronary intervention (PCI), a less invasive approach to treating coronary artery disease, is used more frequently than coronary bypass surgery in Ontario. The number of percutaneous coronary intervention procedures funded by the Ontario Ministry of Health and Long-term Care is expected to increase from approximately 17, 780 in 2004/2005 to 22,355 in 2006/2007 (an increase of 26%), with about 95% requiring the placement of one or more stents. Restenosis following percutaneous coronary interventions involving bare metal stents occurs in 15% to 30% of the cases, mainly because of smooth muscle proliferation and migration, and production of extracellular matrix. In-stent restenosis has been linked to suboptimal stent expansion and inadequate lesion coverage, while stent thrombosis has been attributed to incomplete stent-to-vessel wall apposition. Since coronary angiography (the imaging tool used to guide stent placement) has been shown to be inaccurate in assessing optimal stent placement, and IVUS can provide better views of the vessel lumen, the clinical utility of IVUS as an imaging tool adjunctive to coronary angiography in coronary intervention procedures has been explored in clinical studies. Method A systematic review was conducted to answer the following questions: What are the procedure-related complications associated with IVUS? Does IVUS used in conjunction with angiography to guide percutaneous interventions improve patient outcomes compared to angiographic guidance without IVUS? Who would benefit most in terms of clinical outcomes from the use of IVUS adjunctive to coronary angiography in guiding PCIs? What is the effectiveness of IVUS guidance in the context of drug-eluting stents? What is the cost-effectiveness ratio and budget impact of adjunctive IVUS in PCIs in Ontario? A systematic search of databases OVID MEDLINE, EMBASE, MEDLINE In-Process & Other Non-Indexed Citations, The Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) database for the period beginning in May 2001 until the day of the search, November 4, 2005 yielded 2 systematic reviews, 1 meta-analysis, 6 randomized controlled trials, and 2 non-randomized studies on left main coronary arteries. The quality of the studies ranged from moderate to high. These reports were combined with reports from a previous systematic review for analysis. In addition to qualitative synthesis, pooled analyses of data from randomized controlled studies using a random effect model in the Cochrane Review Manager 4.2 software were conducted when possible. Findings of Literature Review & Analysis Safety Intravascular ultrasound appears to be a safe tool when used in coronary interventions. Periprocedural complications associated with the use of IVUS in coronary interventions ranged from 0.5% in the largest study to 4%. Coronary rupture was reported in 1 study (1/54). Other complications included prolonged spasms of the artery after stenting, dissection, and femoral aneurysm. Effectiveness Based on pooled analyses of data from randomized controlled studies, the use of intravascular ultrasound adjunctive to coronary intervention in percutaneous coronary interventions using bare metal stents yielded the following findings: For lesions predominantly at low risk of restenosis: There were no significant differences in preintervention angiographic minimal lumen diameter between the IVUS-guided and angiography-guided groups. IVUS guidance resulted in a significantly larger mean postintervention angiographic minimal lumen diameter (weighted mean difference of 0.11 mm, P = .0003) compared to angiographic guidance alone. The benefit in angiographic minimal lumen diameter from IVUS guidance was not maintained at 6-month follow-up, when no significant difference in angiographic minimal lumen diameter could be detected between the two arms (weighted mean difference 0.08, P = .13). There were no statistically significant differences in angiographic binary restenosis rates between IVUS-guidance and no IVUS guidance (Odds ratio [OR] 0.87 in favour of IVUS, 95% Confidence Interval [CI] [0.64–1.18], P = 0.37). IVUS guidance resulted in a reduction in the odds of target lesion revascularization (repeat percutaneous coronary intervention or coronary bypass graft) compared to angiographic guidance alone. The reduction was statistically significant at a follow-up period of 6 months to 1 year, and at a follow-up period of 18 month to 2 years (OR 0.52 in favour of IVUS, 95% CI [0.33–0.81], P = .004). Total revascularization rate (either target lesion or target vessel revascularization) was significantly lower for IVUS-guided patients at 18 months to 2.5 years after intervention (OR 0.43 in favour of IVUS, 95% CI [0.29–0.63], p < .0001). There were no statistically significant differences in the odds of death (OR 1.36 in favour of no IVUS, P =0.65) or myocardial infarction (OR 0.95 in favour of IVUS, P = 0.93) between IVUS-guidance and angiographic guidance alone at up to 2.5 years of follow-up The odds of having a major cardiac event (defined as death, myocardial infarction, and target lesion or target vessel revascularization) were significantly lower for patients with IVUS guidance compared to angiographic guidance alone during follow-up periods of up to 2.5 years (OR 0.53, 95% CI [0.36–0.78], P = 0.001). Since there were no significant reductions in the odds of death or myocardial infarction, the reduction in the odds of combined events reflected mainly the reduction in revascularization rates. For lesions at High Risk of Restenosis: There is evidence from one small, randomized controlled trial (n=150) that IVUS-guided percutaneous coronary intervention in long de novo lesions (>20 mm) of native coronary arteries resulted in statistically significant larger minimal lumen Diameter, and statistically significant lower 6-month angiographic binary restenosis rate. Target vessel revascularization rate and the rate of combined events were also significantly reduced at 12 months. A small subgroup analysis of a randomized controlled trial reported no benefit in clinical or angiographic outcomes for IVUS-guided percutaneous coronary interventions in patients with diabetes compared to those guided by angiography. However, due to the nature and size of the analysis, no firm conclusions could be reached. Based on 2 small, prospective, non-randomized controlled studies, IVUS guidance in percutaneous coronary interventions of left main coronary lesions using bare metal stents or drug-eluting stents did not result in any benefits in angiographic or clinical outcomes. These findings need to be confirmed. Interventions Using Drug-Eluting Stents There is presently no evidence on whether the addition of IVUS guidance during the implantation of drug-eluting stents would reduce incomplete stent apposition, or improve the angiographic or clinical outcomes of patients. Ontario-Based Economic Analysis Cost-effectiveness analysis showed that PCIs using IVUS guidance would likely be less costly and more effective than PCIs without IVUS guidance. The upfront cost of adjunctive use of IVUS in PCIs ranged from $1.56 million at 6% uptake to $13.04 million at 50% uptake. Taking into consideration cost avoidance from reduction in revascularization associated with the use of IVUS, a net saving of $0.63 million to $5.2 million is expected. However, since it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS can be generalized to clinical settings in Ontario, further analysis on the budget impact and cost-effectiveness need to be conducted once Ontario-specific revascularization rates are verified. Factors to be Considered in the Ontario Context Applicability of Findings to Ontario The interim analysis of an Ontario field evaluation that compared drug-eluting stents to bare metal stents showed that the revascularization rates in low-risk patients with bare metal stents were much lower in Ontario compared to rates reported in randomized controlled trials (7.2% vs >17 %). Even though IVUS is presently not routinely used in the stenting of low-risk patients in Ontario, the revascularization rates in these patients in Ontario were shown to be lower than those reported for the IVUS groups reported in published studies. Based on this information and previous findings from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rates from IVUS guidance can be generalized to Ontario. In light of the above findings, it is advisable to validate the reported benefits of IVUS guidance in percutaneous coronary interventions involving bare metal stents in the Ontario context. Licensing Status As of January 16, 2006, Health Canada has licensed 10 intravascular ultrasound imaging systems/catheters for transluminal intervention procedures, most as class 4 medical devices. Current Funding IVUS is presently not an insured procedure under the Ontario Health Insurance Plan and there are no professional fees for this procedure. All costs related to the use of IVUS are covered within hospitals’ global budgets. A single use IVUS catheter costs approximately $900CDN and the procedure adds approximately 20 minutes to 30 minutes to a percutaneous coronary intervention procedure. Diffusion According to an expert consultant, current use of IVUS in coronary interventions in Ontario is probably limited to high-risk cases such as interventions in long lesions, small vessels, and bifurcated lesions for which images from coronary angiography are indeterminate. It was estimated that IVUS is being used in about 6% of all percutaneous coronary interventions at a large Ontario cardiac centre. Expert Opinion IVUS greatly enhances the cardiac interventionists’ ability to visualize and assess high-risk lesions such as long lesions, narrow lesions, and bifurcated lesions that may have indeterminate angiographic images. Information from IVUS in these cases facilitates the choice of the most appropriate approach for the intervention. Conclusion The use of adjunctive IVUS in PCIs using bare metal stents in lesions predominantly at low risk for restenosis had no significant impact on survival, myocardial infarction, or angiographic restenosis rates up to 2.5 years after intervention. The use of IVUS adjunctive to coronary angiography in percutaneous coronary interventions using bare metal stents in lesions predominantly at low risk for restenosis significantly reduced the target lesion and target vessel revascularization at a follow-up period of 18 months to 2.5 years. One small study suggests that adjunctive IVUS in PCIs using bare metal stents in long lesions (>20 mm) significantly improved the 6-month angiographic restenosis rate and one-year target lesion revascularization rate. These results need to be confirmed with large randomized controlled trials. Based on information from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS in the placement of bare metal stents can be generalized to clinical settings in Ontario. There is presently insufficient evidence available to determine the impact of adjunctive IVUS in percutaneous interventions in high-risk lesions (other than long lesions) or in PCIs using drug-eluting stents. PMID:23074482

  15. [Vascular malformations in the Williams-Beuren syndrome: report of three new cases].

    PubMed

    Sator, Hicham; Rhouni, Fatima Ezzahra; Benjouad, Ibitihale; Rhouni, Fatima Ezzahra; Benjouad, Ibitihale; Dafiri, Rachida; Chat, Latifa

    2016-01-01

    The Williams-Beuren syndrome is a rare genetic disease. It combines classically specific facial dysmorphism, cardiovascular malformations and specific neuropsychological profile. We report three cases of Williams-Beuren syndrome in children with particular emphasis on vascular abnormalities observed on CT angiography and MR angiography.

  16. [The improved design of table operating box of digital subtraction angiography device].

    PubMed

    Qi, Xianying; Zhang, Minghai; Han, Fengtan; Tang, Feng; He, Lemin

    2009-12-01

    In this paper are analyzed the disadvantages of CGO-3000 digital subtraction angiography table Operating Box. The authors put forward a communication control scheme between single-chip microcomputer(SCM) and programmable logic controller(PLC). The details of hardware and software of communication are given.

  17. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A; Quiles, Katherine G; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2018-01-01

    The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis.

  18. Postmortem whole-body computed tomography angiography visualizing vascular rupture in a case of fatal car crash.

    PubMed

    Flach, Patricia M; Ross, Steffen G; Bolliger, Stephan A; Preiss, Ulrich S; Thali, Michael J; Spendlove, Danny

    2010-01-01

    In addition to the increasingly significant role of multislice computed tomography in forensic pathology, the performance of whole-body computed tomography angiography provides outstanding results. In this case, we were able to detect multiple injuries of the parenchymal organs in the upper abdomen as well as lesions of the brain parenchyma and vasculature of the neck. The radiologic findings showed complete concordance with the autopsy and even supplemented the autopsy findings in areas that are difficult to access via a manual dissection (such as the vasculature of the neck). This case shows how minimally invasive computed tomography angiography can serve as an invaluable adjunct to the classic autopsy procedure.

  19. Congenital Anomaly of Single Dominant Right Coronary Artery with Hypoplastic Left Coronary Artery.

    PubMed

    Chuang, Cheng-Yen; Chen, Yen-Chou; Cheng, Ho-Shun; Hsieh, Ming-Hsiung

    2015-11-01

    With the popularization of new imaging technology, more people are deciding to undergo non-invasive studies such as multidetector computerized tomography (MDCT) before receiving coronary angiography. For this reason, coronary anomalies of coronary artery are being encountered more frequently. We here report a 68-year-old male presenting with typical angina. The MDCT images suggested chronic total occlusion of the left anterior descending (LAD) artery with collateral circulation from the right coronary artery (RCA). The patient's coronary angiography showed a congenital coronary anomaly with a single dominant RCA supplying the entire coronary circulation of the heart with both LAD and left circumflex artery hypoplasia. Angiography; Anomaly; Computerized tomography; Coronary artery.

  20. Correlation of echo-Doppler aortic valve regurgitation index with angiographic aortic regurgitation severity.

    PubMed

    Chen, Ming; Luo, Huai; Miyamoto, Takashi; Atar, Shaul; Kobal, Sergio; Rahban, Masoud; Brasch, Andrea V; Makkar, Rajendra; Neuman, Yoram; Naqvi, Tasneem Z; Tolstrup, Kirsten; Siegel, Robert J

    2003-09-01

    We assessed aortic regurgitation (AR) severity by utilizing multiple echo-Doppler variables in comparison with AR severity by aortic root angiography. Patients were divided into 3 groups: mild, moderate, and severe. An AR index (ARI) was developed, comprising 5 echocardiographic parameters: ratio of color AR jet height to left ventricular outlet flow diameter, AR signal density from continuous-wave Doppler, pressure half-time, left ventricular end-diastolic diameter, and aortic root diameter. There was a strong correlation between AR severity by angiography and the calculated echo-Doppler ARI (r = 0.84, p = 0.0001). As validated by aortic angiography, the ARI is an accurate reflection of AR severity.

  1. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    PubMed

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion revascularization at 24 months. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00986752. © 2017 American Heart Association, Inc.

  2. Is carbon dioxide a safe and good alternative for diatrizoate meglumine as a contrast in digital subtraction angiography?

    PubMed Central

    Hegde, U. N.; Khanapet, M. S.; Rajapurkar, M. M.; Gang, S. D.; Gohel, K. D.; Rane, G.; Parikh, P.; Patil, D.; Desai, T.; Patil, P.; Kelawala, N.

    2009-01-01

    Contrast-induced nephropathy is well-known sequelae of iodinated contrast (diatrizoate meglumine). Carbon dioxide (CO2) can be used as an alternative contrast agent. The aim of this study was to compare the renal injury and the quality of images of aortogram using iodinated contrast versus CO2 using digital subtraction angiography (DSA). This prospective randomized study was done in 29 healthy dogs using DSA aortogram. Dogs were randomly assigned to receive iodinated contrast or CO2. 6-F pigtail catheter was introduced via femoral artery approach to perform aortogram under general anesthesia. Serum creatinine (S.Cr.) and urinary enzymes, namely: N-acetyl D-glucosaminidase (NAG), alanine aminopeptidase (AAP), and gamma glutamyl transferase (GGT), were measured before and 48 hours after aortogram. There was no change in S.Cr. in both the groups. Significantly more enzymuria was seen following iodinated contrast than CO2. Enzymuria pre and postaortogram following the iodinated contrast was GGT: 14.9 ± 5.92 vs. 26.2 ± 15.1 (P = 0.001), NAG: 1.63 ± 0.90 vs. 3.6 ± 2.14 (P = 0.0001), and AAP: 1.51 ± 0.75 vs. 3.38 2.41 (P = 0.001), and in the CO2 group was GGT: 15.5 ± 4.9 vs. 21.1 ± 9.04 (P = 0.02), NAG: 2.12 ± 1.06 vs. 3.82 3.27 (P = 0.08), and AAP: 1.28 ± 0.76 vs. 2.51 ± 1.72 (P = 0.03). More than 50% increase over the preprocedural value was significantly less following CO2. Images obtained with iodinated contrast were superior to those with CO2, however, the quality of image with CO2 was adequate for delineation of the renal artery and major branches. Both iodinated contrast and CO2 cause significant enzymuria. More severe enzymuria (>50% increase) was seen significantly less with the use of CO2. Quality of images is better with iodinated contrast. PMID:20352006

  3. The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilic, Nikola, E-mail: fosafosa75@yahoo.com; Davidovic, Lazar; Koncar, Igor

    Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographicmore » evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.« less

  4. [Non-contrast time-resolved magnetic resonance angiography combining high resolution multiple phase echo planar imaging based signal targeting and alternating radiofrequency contrast inherent inflow enhanced multi phase angiography combining spatial resolution echo planar imaging based signal targeting and alternating radiofrequency in intracranial arteries].

    PubMed

    Nakamura, Masanobu; Yoneyama, Masami; Tabuchi, Takashi; Takemura, Atsushi; Obara, Makoto; Sawano, Seishi

    2012-01-01

    Detailed information on anatomy and hemodynamics in cerebrovascular disorders such as AVM and Moyamoya disease is mandatory for defined diagnosis and treatment planning. Arterial spin labeling technique has come to be applied to magnetic resonance angiography (MRA) and perfusion imaging in recent years. However, those non-contrast techniques are mostly limited to single frame images. Recently we have proposed a non-contrast time-resolved MRA technique termed contrast inherent inflow enhanced multi phase angiography combining spatial resolution echo planar imaging based signal targeting and alternating radiofrequency (CINEMA-STAR). CINEMA-STAR can extract the blood flow in the major intracranial arteries at an interval of 70 ms and thus permits us to observe vascular construction in full by preparing MIP images of axial acquisitions with high spatial resolution. This preliminary study demonstrates the usefulness of the CINEMA-STAR technique in evaluating the cerebral vasculature.

  5. Calibration of optical coherence tomography angiography with a microfluidic chip

    NASA Astrophysics Data System (ADS)

    Su, Johnny P.; Chandwani, Rahul; Gao, Simon S.; Pechauer, Alex D.; Zhang, Miao; Wang, Jie; Jia, Yali; Huang, David; Liu, Gangjun

    2016-08-01

    A microfluidic chip with microchannels ranging from 8 to 96 μm was used to mimic blood vessels down to the capillary level. Blood flow within the microfluidic channels was analyzed with split-spectrum amplitude-decorrelation angiography (SSADA)-based optical coherence tomography (OCT) angiography. It was found that the SSADA decorrelation value was related to both blood flow speed and channel width. SSADA could differentiate nonflowing blood inside the microfluidic channels from static paper. The SSADA decorrelation value was approximately linear with blood flow velocity up to a threshold Vsat of 5.83±1.33 mm/s (mean±standard deviation over the range of channel widths). Beyond this threshold, it approached a saturation value Dsat. Dsat was higher for wider channels, and approached a maximum value Dsm as the channel width became much larger than the beam focal spot diameter. These results indicate that decorrelation values (flow signal) in capillary networks would be proportional to both flow velocity and vessel caliber but would be capped at a saturation value in larger blood vessels. These findings are useful for interpretation and quantification of clinical OCT angiography results.

  6. Prevalence and predictors of renal artery stenosis in patients undergoing peripheral and coronary angiography.

    PubMed

    Shukla, Anand N; Madan, Tarun H; Jayaram, Ashwal A; Kute, Vivek B; Rawal, Jayesh R; Manjunath, A P; Udhreja, Satyam

    2013-12-01

    Renal artery stenosis is a potential cause of secondary hypertension, ischemic nephropathy and end-stage renal disease. Atherosclerosis is by far the most common etiology of renal artery stenosis in elderly. We investigated whether the presence of significant atherosclerotic renal artery stenosis (ARAS) with luminal diameter narrowing ≥50 % could be predicted in patients undergoing peripheral and coronary angiography. The records of 3,500 consecutive patients undergoing simultaneous renal angiography along with peripheral and coronary angiography were reviewed. The patients with known renal artery disease were excluded. Prevalence of ARAS was 5.7 %. Significant ARAS (luminal diameter narrowing ≥50 %) was present in 139 patients (3.9 %). Hypertension with altered serum creatinine and triple-vessel CAD were associated with significant renal artery stenosis in multivariate analysis. No significant relationship between the involved coronary arteries like left anterior descending, left circumflex, right coronary artery and ARAS was found. Only hypertension and altered serum creatinine were associated with bilateral ARAS. Extent of CAD or risk factors like diabetes, hyperlipidemia or smoking did not predict the unilateral or bilateral ARAS. Prevalence of ARAS among the patients in routine cardiac catheterization was 5.7 %. Hypertension is closely associated with significant ARAS. Significant CAD in the form of triple-vessel disease and altered renal function tests are closely associated with ARAS. They predict the presence of significant renal artery stenosis in patients undergoing routine peripheral and coronary angiography. Moreover, hypertension and altered renal functions predict bilateral ARAS.

  7. Fellow Eye Changes in Patients with Nonischemic Central Retinal Vein Occlusion: Assessment of Perfused Foveal Microvascular Density and Identification of Nonperfused Capillaries

    PubMed Central

    Pinhas, Alexander; Dubow, Michael; Shah, Nishit; Cheang, Eric; Liu, Chun L.; Razeen, Moataz; Gan, Alexander; Weitz, Rishard; Sulai, Yusufu N.; Chui, Toco Y.; Dubra, Alfredo; Rosen, Richard B.

    2016-01-01

    Purpose Eyes fellow to nonischemic central retinal vein occlusion (CRVO) were examined for abnormalities, which might explain their increased risk for future occlusion, using adaptive optics scanning light ophthalmoscope fluorescein angiography. Methods Adaptive optics scanning light ophthalmoscope fluorescein angiography foveal microvascular densities were calculated. Nonperfused capillaries adjacent to the foveal avascular zone were identified. Spectral domain optical coherence tomography, ultrawide field fluorescein angiographies, and microperimetry were also performed. Results Ten fellow eyes of nine nonischemic CRVO and 1 nonischemic hemi-CRVO subjects and four affected eyes of three nonischemic CRVO and one nonischemic hemi-CRVO subjects were imaged. Ninety percent of fellow eyes and 100% of affected eyes demonstrated at least 1 nonperfused capillary compared with 31% of healthy eyes. Fellow eye microvascular density (35 ± 3.6 mm−1) was significantly higher than that of affected eyes (25 ± 5.2 mm−1) and significantly lower than that of healthy eyes (42 ± 4.2 mm−1). Compared with healthy controls, spectral domain optical coherence tomography thicknesses showed no significant difference, whereas microperimetry and 2/9 ultrawide field fluorescein angiography revealed abnormalities in fellow eyes. Conclusion Fellow eye changes detectable on adaptive optics scanning light ophthalmoscope fluorescein angiography reflect subclinical pathology difficult to detect using conventional imaging technologies. These changes may help elucidate the pathogenesis of nonischemic CRVO and help identify eyes at increased risk of future occlusion. PMID:25932560

  8. Variations of the superficial middle cerebral vein: classification using three-dimensional CT angiography.

    PubMed

    Suzuki, Y; Matsumoto, K

    2000-05-01

    Classification of variations of the superficial middle cerebral vein (SMCV) remains ambiguous. We propose a new classification system based on embryologic development for preoperative examination. Three-dimensional CT angiography was used to evaluate 500 SMCVs (in 250 patients). The outflow vessels from the SMCV were classified into seven types on the basis of embryologic development. The 3D CT angiograms in axial stereoscopic and oblique views and multiple intensity projection images were evaluated by the same neurosurgeon on two occasions. Inconsistent interpretations were regarded as equivocal. Three-dimensional CT angiography clearly depicted the SMCV running along the lesser wing or the middle cranial fossa. However, the outflow vessel could not be confirmed as the sphenoparietal, cavernous, or emissary type in 39 (8%) of the sides. SMCVs running in the middle cranial fossa to join the transverse sinus or superior petrosal sinus were accurately identified. SMCVs were present in 456 sides: 62% entered the sphenoparietal sinus or the cavernous sinus and 12% joined the emissary vein. Nine vessels were the superior petrosal type, 10 the basal type, 12 the squamosal type, and 44 the undeveloped type. Three-dimensional CT angiography can depict the vessels and their anatomic relationship to the bone structure, allowing identification of the SMCV variant in individual patients. Preoperative planning for skull base surgery requires such information to reduce the invasiveness of the procedure. With the use of our classification system, 3D CT angiography can provide exact and practical information concerning the SMCV.

  9. Safety of Diagnostic Cerebral and Spinal Digital Subtraction Angiography in a Developing Country: A Single-Center Experience.

    PubMed

    Bashir, Qasim; Ishfaq, Asim; Baig, Ammad Anwar

    2018-02-01

    Digital subtraction angiography (DSA) remains the gold standard imaging modality for cerebrovascular disorders. In contrast to developed countries, the safety of the procedure is not extensively reported from the developing countries. Herein, we present a retrospective analysis of the basic technique, indications, and outcomes in 286 patients undergoing diagnostic cerebral and spinal angiography in a developing country, Pakistan. A retrospective review of patient demographics, procedural technique and complication rates of 286 consecutive patients undergoing the diagnostic cerebral/spinal angiography procedure at one institution from May 2013 to December 2015 was performed. Neurological, systemic, or local complications occurring within and after 24 h of the procedure were recorded. Mean age reported for all patients was 49.7 years. Of all the 286 cases, 175 were male (61.2%) and the rest female (111, 38.8%). Cerebral DSA was performed in 279 cases (97.6%), with 7 cases of spinal DSA (2.4%). Subarachnoid hemorrhage was the most common indication for DSA accounting for 88 cases (30.8%), closely followed by stroke (26.6%) and arteriosclerotic vascular disease (23.1%). No intra- or post-procedural neurological complications of any severity were seen in any of the 286 cases. One case of asymptomatic aortic dissection was reported (0.3%) in the entire cohort of patient population. Diagnostic cerebral/spinal digital subtraction angiography was found to be safe in Pakistan, with complication rates at par with and comparable to those reported in the developed world.

  10. Fluorescein angiography of the bladder: technique and relevance to bladder cancer and interstitial cystitis patients.

    PubMed

    Zimmern, P E; Laub, D; Leach, G E

    1995-07-01

    Fluorescein angiography has been used in the study of bleeding vessels, neovascularity, tumors and ischemic tissues in a variety of disorders. This pilot study was designed to evaluate the feasibility, safety and relevance of this interesting technology for the evaluation of bladder wall vessels in patients with interstitial cystitis and bladder cancer. Five patients with National Institutes of Health defined interstitial cystitis symptoms and 10 with bladder cancer were studied during cytoscopy while they were under general anesthesia. A yellow-green barrier filter (520 nm.) was placed over the cystoscope eyepiece and a blue exciter filter (465 nm.) was attached to the light source. Patients received a 5 ml. bolus of 10% fluorescein intravenously. After hydrodistension, glomerulations in interstitial cystitis patients were more prominent with fluorescein angiography and occurred in the venule phase. Areas of papillary transitional cell tumor and carcinoma in situ developed a brilliant yellow-green fluorescence. Adjacent normal urothelium was nonfluorescent and provided a contrasting dark background facilitating the detection of all lesions. No allergic reaction or other adverse effect related to the fluorescein injection was observed. These unique observations in a limited number of patients suggest that fluorescein angiography of the bladder is a safe and simple procedure. This preliminary report underscores the relevance of fluorescein angiography in the detection of bladder tumor and offers a new approach to the evaluation of bladder wall vessels in interstitial cystitis patients.

  11. Wall-to-lumen ratio of intracranial arteries measured by indocyanine green angiography

    PubMed Central

    Nakagawa, Daichi; Shojima, Masaaki; Yoshino, Masanori; Kin, Taichi; Imai, Hideaki; Nomura, Seiji; Saito, Toki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2016-01-01

    Background: The wall-to-lumen ratio (WLR) is an important parameter in vascular medicine because it indicates the character of vascular wall as well as the degree of stenosis. Despite the advances in medical imaging technologies, it is still difficult to measure the thin-walled normal intracranial arteries, and the reports on the WLR of normal intracranial artery are limited. It might be possible to calculate the WLR using the indocyanine green (ICG) angiography, which is used to observe intracranial vessels during microsurgery. Purpose: To evaluate the WLR of normal intracranial arteries using ICG angiography. Materials and Methods: From the three cases in which ICG angiography was recorded with a ruler during microsurgery, 20 measurement points were chosen for the analysis. The ICG was injected intravenously with a dose of 0.2 mg/kg, and the vessels were inspected at high magnification using an operating microscope equipped with near-infrared illumination system. The vessel outer diameter and the luminal diameter were measured using the images before and after the ICG arrival based on the pixel ratio method using a ruler as reference, respectively. The WLR was calculated as 0.5 × (vessel outer diameter − vessel luminal diameter). Results: The WLR (mean ± standard deviation) of normal intracranial arteries was 0.086 ± 0.022. The WLR tended to be high in small arteries. Conclusion: The WLR of normal intracranial arteries calculated using ICG angiography was consistent with the WLR reported in the previous reports based on human autopsy. PMID:27695538

  12. Mono-energy coronary angiography with a compact light source

    NASA Astrophysics Data System (ADS)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  13. Magnetic Resonance Angiography in the Diagnosis of Cerebral Arteriovenous Malformation and Dural Arteriovenous Fistulas: Comparison of Time-Resolved Magnetic Resonance Angiography and Three Dimensional Time-of-Flight Magnetic Resonance Angiography

    PubMed Central

    Cheng, Yu-Ching; Chen, Hung-Chieh; Wu, Chen-Hao; Wu, Yi-Ying; Sun, Ming-His; Chen, Wen-Hsien; Chai, Jyh-Wen; Chi-Chang Chen, Clayton

    2016-01-01

    Background Traditional digital subtraction angiography (DSA) is currently the gold standard diagnostic method for the diagnosis and evaluation of cerebral arteriovenous malformation (AVM) and dural arteriovenous fistulas (dAVF). Objectives The aim of this study was to analyze different less invasive magnetic resonance angiography (MRA) images, time-resolved MRA (TR-MRA) and three-dimensional time-of-flight MRA (3D TOF MRA) to identify their diagnostic accuracy and to determine which approach is most similar to DSA. Patients and Methods A total of 41 patients with AVM and dAVF at their initial evaluation or follow-up after treatment were recruited in this study. We applied time-resolved angiography using keyhole (4D-TRAK) MRA to perform TR-MRA and 3D TOF MRA examinations simultaneously followed by DSA, which was considered as a standard reference. Two experienced neuroradiologists reviewed the images to compare the diagnostic accuracy, arterial feeder and venous drainage between these two MRA images. Inter-observer agreement for different MRA images was assessed by Kappa coefficient and the differences of diagnostic accuracy between MRA images were evaluated by the Wilcoxon rank sum test. Results Almost all vascular lesions (92.68%) were correctly diagnosed using 4D-TRAK MRA. However, 3D TOF MRA only diagnosed 26 patients (63.41%) accurately. There were statistically significant differences regarding lesion diagnostic accuracy (P = 0.008) and venous drainage identification (P < 0.0001) between 4D-TRAK MRA and 3D TOF MRA. The results indicate that 4D-TRAK MRA is superior to 3D TOF MRA in the assessment of lesions. Conclusion Compared with 3D TOF MRA, 4D-TRAK MRA proved to be a more reliable screening modality and follow-up method for the diagnosis of cerebral AVM and dAVF. PMID:27679690

  14. Does angiography increase the risk of impairment in renal function during non-operative management of patients with blunt splenic injuries? A cross-sectional study in southern Taiwan

    PubMed Central

    Hsieh, Ting-Min; Tsai, Tzu-Hsien; Lin, Chih-Che; Hsieh, Ching-Hua

    2016-01-01

    Objectives The aim of the present study was to assess whether angiography after contrast-enhanced CT (CECT) as per the policy of non-operative management would add to the risk of acute kidney injury in patients with blunt splenic injuries (BSIs). Design Cross-sectional study. Setting Taiwan. Participants Patients with BSI aged >16 years, admitted to a level I trauma centre during the period of January 2004 to December 2014, were retrospectively reviewed. A total of 326 patients with BSI with CECT were included in the study, of whom 100 underwent subsequent angiography and 226 did not. Main outcome measures Incidence of contrast-induced nephropathy (CIN) and renal function as measured by the 48-hour serum creatinine (SCr) levels. Results No significant difference between the patients who underwent angiography and those who did not in terms of the initial haemoglobin (Hb), SCr or estimated glomerular filtration rate (eGFR) level on arrival at the emergency department, 48 hours later, or at discharge. No significant difference in the incidence of CIN was found between these two groups of patients regardless of the criteria for identifying CIN. In the group of patients aged ≥55 years, those who underwent angiography had a significantly worse 48-hour SCr level than those who did not undergo the treatment. In addition, there was no significant difference in the 48-hour SCr level between the two groups of patients when subgrouping the patients according to sex, large haemoperitoneum revealed on CT, systolic blood pressure, initial Hb, initial SCr and initial eGFR levels. Conclusions This study demonstrated that angiography does not increase the incidence of CIN, and was not a risk factor to renal function impairment in patients with BSI who had undergone CECT. PMID:27798008

  15. Does angiography increase the risk of impairment in renal function during non-operative management of patients with blunt splenic injuries? A cross-sectional study in southern Taiwan.

    PubMed

    Hsieh, Ting-Min; Tsai, Tzu-Hsien; Lin, Chih-Che; Hsieh, Ching-Hua

    2016-10-21

    The aim of the present study was to assess whether angiography after contrast-enhanced CT (CECT) as per the policy of non-operative management would add to the risk of acute kidney injury in patients with blunt splenic injuries (BSIs). Cross-sectional study. Taiwan. Patients with BSI aged >16 years, admitted to a level I trauma centre during the period of January 2004 to December 2014, were retrospectively reviewed. A total of 326 patients with BSI with CECT were included in the study, of whom 100 underwent subsequent angiography and 226 did not. Incidence of contrast-induced nephropathy (CIN) and renal function as measured by the 48-hour serum creatinine (SCr) levels. No significant difference between the patients who underwent angiography and those who did not in terms of the initial haemoglobin (Hb), SCr or estimated glomerular filtration rate (eGFR) level on arrival at the emergency department, 48 hours later, or at discharge. No significant difference in the incidence of CIN was found between these two groups of patients regardless of the criteria for identifying CIN. In the group of patients aged ≥55 years, those who underwent angiography had a significantly worse 48-hour SCr level than those who did not undergo the treatment. In addition, there was no significant difference in the 48-hour SCr level between the two groups of patients when subgrouping the patients according to sex, large haemoperitoneum revealed on CT, systolic blood pressure, initial Hb, initial SCr and initial eGFR levels. This study demonstrated that angiography does not increase the incidence of CIN, and was not a risk factor to renal function impairment in patients with BSI who had undergone CECT. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Multimodal Retinal Imaging in Incontinentia Pigmenti Including Optical Coherence Tomography Angiography: Findings From an Older Cohort With Mild Phenotype.

    PubMed

    Liu, Tin Yan Alvin; Han, Ian C; Goldberg, Morton F; Linz, Marguerite O; Chen, Connie J; Scott, Adrienne W

    2018-05-01

    Incontinentia pigmenti (IP) is a rare, X-linked dominant disease with potentially severe ocular complications that predominantly affect the peripheral retina. However, little is known about its effects on the macula. To describe the structural and vascular abnormalities observed in the maculas of patients with IP and to correlate these findings with peripheral pathologies. Prospective, cross-sectional study at Wilmer Eye Institute, Johns Hopkins University. Five participants with a clinical diagnosis of IP were included and underwent multimodal imaging with ultra-wide-field fluorescein angiography (FA), spectral-domain optical coherence tomography (OCT), and OCT angiography. The structural and vascular abnormalities observed on spectral-domain OCT and OCT angiography and their correlation with peripheral pathologies seen on ultra-wide-field FA. A total of 9 eyes from 5 patients (median age, 20.5 years; range, 8.4-54.2 years) were included. Median Snellen visual acuity was 20/32 (range, 20/16 to 20/63). ultra-wide-field FA-identified retinal vascular abnormalities in all 7 eyes in which FA was obtained. These abnormalities included microaneurysms, areas of nonperfusion, and vascular anastomoses, most of which were peripheral to the standard view of 30° FA with peripheral sweeps. Structural abnormalities were observed in 6 eyes on spectral-domain OCT, including inner retinal thinning and irregularities in the outer plexiform layer. Optical coherence tomography angiography abnormalities were noted in all 9 eyes, including decreased vascular density, abnormal vascular loops, and flow loss in the superficial and deep plexuses, which corresponded to areas of retinal thinning on spectral-domain OCT. Although our study is limited by the small sample size, the findings suggest that multimodal imaging is useful for detecting structural and vascular abnormalities that may not be apparent on ophthalmoscopy in patients with IP. Macular pathologies, especially a decrease in vascular density on OCT angiography, are common. Further studies are needed to characterize further the association between macular and peripheral abnormalities in patients with IP.

  17. ZEISS Angioplex™ Spectral Domain Optical Coherence Tomography Angiography: Technical Aspects.

    PubMed

    Rosenfeld, Philip J; Durbin, Mary K; Roisman, Luiz; Zheng, Fang; Miller, Andrew; Robbins, Gillian; Schaal, Karen B; Gregori, Giovanni

    2016-01-01

    ZEISS Angioplex™ optical coherence tomography (OCT) angiography generates high-resolution three-dimensional maps of the retinal and choroidal microvasculature while retaining all of the capabilities of the existing CIRRUS™ HD-OCT Model 5000 instrument. Angioplex™ OCT angiographic imaging on the CIRRUS™ HD-OCT platform was made possible by increasing the scanning rate to 68,000 A-scans per second and introducing improved tracking software known as FastTrac™ retinal-tracking technology. The generation of en face microvascular flow images with Angioplex™ OCT uses an algorithm known as OCT microangiography-complex, which incorporates differences in both the phase and intensity information contained within sequential B-scans performed at the same position. Current scanning patterns for en face angiographic visualization include a 3 × 3 and a 6 × 6 mm scan pattern on the retina. A volumetric dataset showing erythrocyte flow information can then be displayed as a color-coded retinal depth map in which the microvasculature of the superficial, deep, and avascular layers of the retina are displayed together with the colors red, representing the superficial microvasculature; green, representing the deep retinal vasculature; and blue, representing any vessels present in the normally avascular outer retina. Each retinal layer can be viewed separately, and the microvascular layers representing the choriocapillaris and the remaining choroid can be viewed separately as well. In addition, readjusting the contours of the slabs to target different layers of interest can generate custom en face flow images. Moreover, each en face flow image is accompanied by an en face intensity image to help with the interpretation of the flow results. Current clinical experience with this technology would suggest that OCT angiography should replace fluorescein angiography for retinovascular diseases involving any area of the retina that can be currently scanned with the CIRRUS™ HD-OCT instrument and may replace fluorescein angiography and indocyanine green angiography for some choroidal vascular diseases. © 2016 S. Karger AG, Basel.

  18. [APPLICATION VALUE OF INDOCYANINE GREEN ANGIOGRAPHY IN FLAP RECONSTRUCTIVE SURGERY].

    PubMed

    Yang, Kai; Mu, Lan; Liu, Yan; Peng, Zhe; Li, Guangxue

    2015-09-01

    To investigate the utility of indocyanine green angiography in flap reconstructive surgery and possibility of decrease the complications. Indocyanine green angiography was performed on 14 patients undergoing flap reconstructive surgery between February and December 2014 to evaluate the blood perfusion of the flap and to adjust the operation plan. Of 14 cases, 2 were male and 12 were female, aged 23-58 years (mean, 35.5 years); 11 flaps were used for breast reconstruction [including 3 free deep inferior epigastric antery perforator (DIEP) flaps, 4 pedicled transverse rectus abdominis myocutaneous flaps (TRAM), 2 pedicled TRAM and free TRAM, and 2 pedicled latissimus dorsi myocutaneous flaps and prosthesis], 1 pedicled latissimus dorsi myocutaneous flap for repairing chest wall defect, 1 pedicled profunda artery perforator (PAP) flap for upper leg defect, and 1 pedicled descending genicular artery perforator flap for knee defect. The size of the flaps ranged from 9 cm x 6 cm to 26 cm x 12 cm. A total of 32 indocyanine green angiography were performed. There was no adverse reactions to the infusion of indocyanine green. The surgery management was adjusted according to results of indocyanine green angiography findings in 5 of 14 cases. The distal part of flap were discarded because of poor perfusion in 3 cases (1 DIEP flap, 1 TRAM, and 1 PAP flap) and the other 2 cases (pedicled TRAM) needed additional free anastomosis to ensure sufficient blood supply (pedicled TRAM and free TRAM); the other flaps were harvested according to preoperative plan and repaired defect successfully. The mean follow-up was 5 months (range, 1-9 months). The other flaps survived without infection or fat necrosis except 1 PAP flap with distal necrosis. Intraoperative indocyanine green angiography can provide real-time information of flap perfusion and then the operation plan can be adjusted in time to ensure the flap survival.

  19. Whom should we SPY? A cost analysis of laser-assisted indocyanine green angiography in prevention of mastectomy skin flap necrosis during prosthesis-based breast reconstruction.

    PubMed

    Kanuri, Arjun; Liu, Allen S; Guo, Lifei

    2014-04-01

    Skin flap necrosis is the most common complication following prosthesis-based breast reconstruction. Many studies have reported on the efficacy of laser-assisted indocyanine green angiography (SPY Elite System) in detecting flap necrosis. A cost-effectiveness analysis of laser-assisted indocyanine green angiography is lacking. The authors performed a retrospective review of all consecutive immediate postmastectomy prosthesis-based reconstructions at the Brigham and Women's Hospital over a 7-year 10-month period. The rate of mastectomy skin flap necrosis and related implant loss was determined for the entire cohort and for the subgroups of patients at increased risk for developing this complication: smokers, obese patients, and patients with large breasts. Cost of treating implant loss and skin flap necrosis was calculated based on the average treatment courses and costs at the authors' institution. The cost of the SPY was obtained from LifeCell Corp. From January of 2004 through October of 2011, 79 of 710 prosthesis-based breast reconstructions (11.1 percent) developed mastectomy skin flap necrosis requiring excision and reclosure. Performing laser-assisted indocyanine green angiography on the entire cohort would result in an additional cost of $1537.30 per case of flap necrosis prevented. If laser-assisted indocyanine green angiography was performed on only these high-risk subgroups, the cost savings per case of flap necrosis prevented is $2098.80 for smokers, $5162.30 for patients with a body mass index greater than 30, and $1892.70 for patients with mastectomy weight greater than 800 g. Laser-assisted indocyanine green angiography is not cost-effective as a preventative measure for flap necrosis if used indiscriminately on all patients undergoing prosthesis-based breast reconstructions, but it is cost-effective for high-risk patients, such as smokers, obese patients, and patients with large breasts.

  20. Visual and Quantitative Assessment of Coronary Stenoses at Angiography Versus Fractional Flow Reserve: The Impact of Risk Factors.

    PubMed

    Adjedj, Julien; Xaplanteris, Panagiotis; Toth, Gabor; Ferrara, Angela; Pellicano, Mariano; Ciccarelli, Giovanni; Floré, Vincent; Barbato, Emanuele; De Bruyne, Bernard

    2017-07-01

    The correlation between angiographic assessment of coronary stenoses and fractional flow reserve (FFR) is weak. Whether and how risk factors impact the diagnostic accuracy of angiography is unknown. We sought to evaluate the diagnostic accuracy of angiography by visual estimate and by quantitative coronary angiography when compared with FFR and evaluate the influence of risk factors (RF) on this accuracy. In 1382 coronary stenoses (1104 patients), percent diameter stenosis by visual estimation (DS VE ) and by quantitative coronary angiography (DS QCA ) was compared with FFR. Patients were divided into 4 subgroups, according to the presence of RFs, and the relationship between DS VE , DS QCA , and FFR was analyzed. Overall, DS VE was significantly higher than DS QCA ( P <0.0001); nonetheless, when examined by strata of DS, DS VE was significantly smaller than DS QCA in mild stenoses, although the reverse held true for severe stenoses. Compared with FFR, a large scatter was observed for both DS VE and DS QCA . When using a dichotomous FFR value of 0.80, C statistic was significantly higher for DS VE than for DS QCA (0.712 versus 0.640, respectively; P <0.001). C statistics for DS VE decreased progressively as RFs accumulated (0.776 for ≤1 RF, 0.750 for 2 RFs, 0.713 for 3 RFs and 0.627 for ≥4 RFs; P =0.0053). In addition, in diabetics, the relationship between FFR and angiographic indices was particularly weak (C statistics: 0.524 for DS VE and 0.511 for DS QCA ). Overall, DS VE has a better diagnostic accuracy than DS QCA to predict the functional significance of coronary stenosis. The predictive accuracy of angiography is moderate in patients with ≤1 RFs, but weakens as RFs accumulate, especially in diabetics. © 2017 American Heart Association, Inc.

  1. The Role of Intraoperative Cerebral Angiography in Transorbital Intracranial Penetrating Trauma: A Case Report and Literature Review.

    PubMed

    Riley, Jonathan P; Boucher, Andrew B; Kim, Denise S; Barrow, Daniel L; Reynolds, Matthew R

    2017-01-01

    Transorbital intracranial penetrating trauma with a retained intracranial foreign body is a rare event lacking a widely accepted diagnostic and therapeutic algorithm. Intraoperative catheter angiography (IOA) has been advocated by some authorities to rule out cerebrovascular injury before and/or after removal of the object, but no standard of care currently exists. A 19-year-old man was involved in a construction site accident whereby a framing nail penetrated the left globe, traversed the lateral bony orbit, and terminated in the midtemporal lobe. No hematoma or injury to the middle cerebral arteries (MCAs) was apparent on noncontrast head computed tomography (CT) or CT angiography, respectively. The foreign body was removed in the operating room under direct visualization after a frontotemporal craniotomy without incident. No significant venous or arterial bleeding was encountered. All visualized MCA branches appeared intact. Indocyanine green videoangiography performed immediately after object removal showed adequate filling of the MCA branches. Given these uneventful clinical and radiographic findings, IOA was not performed. Postoperative head CT and CT angiography showed no obvious neurovascular injury. On postoperative day 2, the patient was noted to have an expressive aphasia. Cerebral angiography showed absent antegrade filling of the angular artery with some retrograde perfusion. Magnetic resonance imaging confirmed an ischemic infarction in the midtemporal lobe. The patient's expressive aphasia improved to near baseline during his hospitalization and he made an excellent clinical recovery. In transorbital intracranial penetrating trauma with a retained intracranial object, we advocate microsurgical removal of the object under direct visualization followed immediately by IOA. IOA should be strongly considered even in the setting of minimal intraoperative bleeding and normal findings on videoangiography (a course of action that was not followed in the present case). Given that CT angiography and intraoperative videoangiography may miss a potentially treatable traumatic arterial injury, IOA can help determine whether cerebral revascularization may be necessary. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Hybrid operating room concept for combined diagnostics, intervention and surgery in acute type A dissection.

    PubMed

    Tsagakis, Konstantinos; Konorza, Thomas; Dohle, Daniel Sebastian; Kottenberg, Eva; Buck, Thomas; Thielmann, Matthias; Erbel, Raimund; Jakob, Heinz

    2013-02-01

    In acute type A dissection (AAAD), it is commonly decided to carry out immediate surgical repair without invasive diagnostics. The hybrid operating room (Hybrid OR) concept encompasses simultaneous haemodynamic control, non-invasive and invasive diagnostics and immediate surgical and/or interventional treatment. Results over a seven-year period are presented here. From March 2004 to March 2011, 1883 cardiological and surgical patients were treated in a Hybrid OR. Of these, 124 patients (age 60 ± 13, 64% male) diagnosed with AAAD were operated upon. External computed tomography (CT) was available for 87% (108/124) of cases and angiography in 15% (19/124). Preoperative transoesophageal echocardiography (TEE) was done in all patients and angiography in 57% (71/124). Surgery was performed without angiography in 27% (34/124), of which 14% (17/124) was due to shock. Postoperative control angiography followed in 18% (22/124) due to suspected ongoing malperfusion. Preoperative angiography was performed in 71 patients, and no angiography related complications were observed during the procedure. A total of 32% (23/71) of these underwent coronary artery bypass graft (CABG)--for newly-diagnosed coronary artery disease in 21% of cases and for coronary malperfusion in 11%. Visceral/peripheral malperfusion syndromes, necessitating primary endovascular intervention, were detected in 23% (16/71). Ascending aorta replacement was performed in 100% (124/124) of patients, arch replacement in 88% (109/124) and descending aorta repair in 35% (44/124). Five postoperative endovascular interventions became necessary due to persistent malperfusion. In-hospital mortality was 13% (12/90) in patients who had undergone preoperative invasive diagnostics and 24% (8/34) in patients who had not. The Hybrid OR concept enables the exact diagnosis of coronary status and downstream malperfusion sites and influences the design of surgical and/or endovascular treatment, without time delay and at negligible risk to the patient.

  3. [Comparative evaluation of ultrasonography, computerized tomography, angiography and lipiodol CT in defining extent of hepatocarcinoma. A multicenter study].

    PubMed

    Dalla Palma, L; Pozzi Mucelli, R; Sponza, M; Bartolozzi, C; De Santis, M; Gandini, G; Mannella, P; Matricardi, L; Rossi, C; Simonetti, G

    1995-03-01

    The authors report the results of a multicentric trial on hepatocellular carcinoma (HCC) patients, whose lesions were confirmed with biopsy or by high (> 400 ng/ml) alpha-fetoprotein levels. The series consisted of 149 patients examined in 8 different centers and submitted to ultrasonography (US), Computed Tomography (CT) before and after contrast agent administration, angiography and Lipiodol CT. According to lesion size and number, the patients were divided with each imaging modality into three groups: a) group 1: unifocal HCC < 5 cm diameter; b) group 2: multifocal HCC with 2-3 nodules and/or tumor mass < 80 ml; c) multifocal HCC with more than 3 nodules (with total tumor mass not exceeding 40% of liver volume) or with total tumor mass > 80 ml. In 77 patients all the examinations were available for comparison. US and CT diagnosed more patients as belonging to group 1 than angiography and Lipiodol CT, while more patients were classified as groups 2 and 3 with angiography and Lipiodol CT, meaning that US and CT may understage some HCC cases (about 15%) because they show a lower number of nodules. This observation was confirmed by the direct comparison between US and Lipiodol CT (in 114 patients), CT and Lipiodol CT (in 103 patients) and angiography and Lipiodol CT (in 116 patients). US and Lipiodol CT were in disagreement in 18 cases, CT and Lipiodol CT in 16 cases and angiography and Lipiodol CT in 13 cases. In most of these cases, Lipiodol CT showed more lesions than the other techniques. The size of the undetected lesions was small, ranging few mm to 2 cm in nearly all cases. To conclude, the results of this multicentric trial show that Lipiodol CT is a fundamental tool to evaluate HCC extent. In contrast, conventional CT appeared not to add any significant piece of information and can therefore be excluded from the diagnostic protocol of HCC.

  4. Nationwide trends in use and timeliness of diagnostic coronary angiography in acute coronary syndromes from 2005 to 2011: Does distance to invasive heart centres matter?

    PubMed

    Hansen, Kim W; Sørensen, Rikke; Madsen, Mette; Madsen, Jan K; Jensen, Jan S; von Kappelgaard, Lene M; Mortensen, Poul E; Galatius, Søren

    2015-08-01

    To examine trends in the use of diagnostic coronary angiography according to distance from home to the nearest invasive heart centre following implementation of fast-track protocols and extensive pre-hospital triaging of acute coronary syndrome patients. We performed a register-based cohort study of all patients admitted to Danish hospitals with incident acute coronary syndrome in 2005-2011. Diagnostic coronary angiography within 60 days of admission was investigated according to distance tertiles (DTs) calculated as range from each patient's home to the nearest invasive heart centre (short DT: <22 km, medium DT: 22-65 km, long DT: >65 km). Cox proportional hazards models were applied.Among the 52,409 patients included, diagnostic coronary angiography was increasingly used during 2005-2011 (short DT: 76% to 81%; medium DT: 74% to 81%; long DT: 69% to 78%; all p-values for trend <0.001). Using the short DT as reference the adjusted hazard ratios for medium DT were 0.87 (0.84-0.89) for 2005-2007, 0.94 (0.90-0.98) for 2008-2009 and 0.94 (0.90-0.98) for 2010-2011. Corresponding figures for long DT were 0.74 (0.72-0.76) for 2005-2007, 0.87 (0.83-0.90) for 2008-2009 and 0.94 (0.90-0.98) for 2010-2011. Length of hospital stay, time to coronary angiography, and 60-day mortality decreased in all DT. This nationwide study found significant increases in diagnostic coronary angiography use over time in incident acute coronary syndrome patients with a relatively larger increase in patients residing farthest from an invasive heart centre. Additionally, selected quality of care measures improved in the entire cohort, suggesting a benefit of national clinical protocols. © The European Society of Cardiology 2014.

  5. Potential impact of clinical use of noninvasive FFRCT on radiation dose exposure and downstream clinical event rate.

    PubMed

    Bilbey, Nicolas; Blanke, Philipp; Naoum, Christopher; Arepalli, Chesnel Dey; Norgaard, Bjarne Linde; Leipsic, Jonathon

    2016-01-01

    This study aims to determine the potential impact of introducing noninvasive fractional flow reserve based on coronary computed tomography angiography (CTA) into clinical practice, with respect to radiation dose exposure and downstream event rate. We modeled a population of 1000 stable, symptomatic patients with suspected coronary artery disease, using the disease prevalence from the CONFIRM registry to estimate the pretest likelihood. Four potential clinical pathways were modeled based on the first noninvasive diagnostic test performed: (1) dobutamine echo; (2) single-photon emission computerized tomography (SPECT); (3) coronary CTA; and (4) CTA+FFRCT and leading to possible invasive coronary angiography. The posttest likelihood of testing positive/negative by each test was based on the presenting disease burden and diagnostic accuracy of each test. The dobutamine echo pathway resulted in the lowest radiation dose of 5.4 mSv, with 4.0 mSv from angiography and 1.4 mSv from percutaneous coronary intervention (PCI). The highest dose was with SPECT, with 26.5 mSv. The coronary computed tomography angiography (cCTA) pathway demonstrated a dose of 14.2 mSv, 3.7 mSv from cCTA, 7.7 mSv from angiography, and 2.8 mSv from PCI. The CTA+FFRCT pathway exhibited a radiation dose of 9.7 mSv, 3.7 mSv for cCTA, 4.2 mSv for angiography, and 1.8 mSv for PCI. Radiation dose exposure for CTA+FFRCT was lower than for SPECT (P<.001). The CTA+FFRCT pathway resulted in the lowest projected death/myocardial infarction rate at 1 year (2.44%) while the dobutamine stress pathway had the highest 1-year event rate (2.84%). Our analysis suggests that integrating FFRCT into the CTA clinical pathway may result in reduced cumulative radiation exposure, while promoting favorable clinical outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. THE SECOND BLIND SPOT: SMALL RETINAL VESSEL VASCULOPATHY AFTER VACCINATION AGAINST NEISSERIA MENINGITIDIS AND YELLOW FEVER.

    PubMed

    Moysidis, Stavros N; Koulisis, Nicole; Patel, Vivek R; Kashani, Amir H; Rao, Narsing A; Humayun, Mark S; Rodger, Damien C

    2017-01-01

    To describe a case of small retinal vessel vasculopathy postvaccination. We report the case of a 41-year-old white man who presented with a "second blind spot," describing a nasal scotoma in the right eye that started 4 days after vaccinations against Neisseria meningitidis and the yellow fever virus, and after a 2-month period of high stress and decreased sleep. Clinical examination, Humphrey visual field testing, and multimodal imaging with fundus photographs, autofluorescence, fluorescein angiography, and spectral domain optical coherence tomography and angiography were performed. Clinical examination revealed a well-circumscribed, triangular area of retinal graying of about 1-disk diameter in size, located at the border of the temporal macula. This corresponded to a deep scotoma similar in size to the physiologic blind spot on Humphrey visual field 24-2 testing. There was mild hypoautofluoresence of this lesion on autofluorescence, hypofluorescence on fluorescein angiography, and focal attenuation of a small artery just distal to the bifurcation of an artery supplying the involved area. Spectral domain optical coherence tomography through the lesion conveyed hyperreflectivity most prominent in the inner and outer plexiform layers, with extension of the hyperreflectivity into the ganglion cell and inner nuclear layers. Spectral domain optical coherence tomography angiography demonstrated arteriolar and capillary dropout, more pronounced in the superficial retinal layer compared to the deeper retinal layer. At 1-month follow-up, his scotoma improved with monitoring, with reduction from -32 dB to -7 dB on Humphrey visual field testing. There was clinical resolution of the area of graying and decreased hyperreflectivity on spectral domain optical coherence tomography, with atrophy of the inner retina. Spectral domain optical coherence tomography angiography showed progression of arteriolar and capillary dropout, more so in the superficial than in the deep capillary plexus. We describe a case of small artery occlusion in a previously healthy patient, 4 days after vaccination against N. meningitidis and yellow fever. Fluorescein angiography yielded greater diagnostic value than OCTA for evaluating the occlusion, whereas spectral domain optical coherence tomography angiography enabled better visualization of capillary dropout and layer-specific assessment. Further research is required to determine whether vaccination in general, or directed specifically at N. meningitidis or yellow fever, is associated with small vessel vasculopathy and the underlying pathogenesis.

  7. Cost-effectiveness of Early Division of the Forehead Flap Pedicle.

    PubMed

    Calloway, Hollin E; Moubayed, Sami P; Most, Sam P

    2017-09-01

    The paramedian forehead flap is considered the gold standard procedure to optimally reconstruct major defects of the nose, but this procedure generally requires 2 stages, where the flap pedicle is divided 3 weeks following the initial surgery to ensure adequate revascularization of the flap from the surrounding recipient tissue bed, which can cost a patient time out of work or away from normal social habits. It has previously been shown that the pedicle may be safely divided after 2 weeks in select patients where revascularization from the recipient bed was confirmed using intraoperative laser fluorescence angiography to potentially save the patient time and money. To demonstrate the cost-effectiveness of takedown of the paramedian forehead flap pedicle after 2 weeks using angiography with indocyanine green (ICG). Retrospective cohort study of all patients who underwent 2-week division of the forehead flap after nasal reconstruction. Patient, tumor, defect, and outcomes data were collected. Cost-minimization analysis was performed by comparing the overall costs of 2-week takedown with angiography to a hypothetical patient undergoing 3-week takedown without angiography. Two-week division of the forehead flap after nasal reconstruction. Cost-minimization analysis performed by calculating the total variable costs for a patient in our cohort vs costs to a theoretical patient for whom angiography was not performed and the pedicle was divided at the 3-week mark. A total of 22 patients were included (mean [SD] age, 70.3 [10.0] years; 8 women [36.4%] and 14 men [63.6%]). The selection criteria for 2-week division of the pedicle are a wound bed with at least 50% vascularized tissue present, partial-thickness defects, and absence of nicotine use. All were divided at the 2-week mark with no instances of flap necrosis. One patient had a squamous eccrine carcinoma histology before reconstruction, all other patients had basal cell carcinoma, squamous cell carcinoma, and melanoma. Cost-minimization analysis showed that the use of angiography with ICG results in cost savings of $177 per patient on average. Two-week takedown of select paramedian forehead flap patients can be performed safely with verification using angiography with ICG. Although this technology inherently adds cost, it is cost-effective, saving a total of $177 per patient. NA.

  8. A study of the effect of dyad practice versus that of individual practice on simulation-based complex skills learning and of students' perceptions of how and why dyad practice contributes to learning.

    PubMed

    Räder, Sune B E W; Henriksen, Ann-Helen; Butrymovich, Vitalij; Sander, Mikael; Jørgensen, Erik; Lönn, Lars; Ringsted, Charlotte V

    2014-09-01

    The aims of this study were (1) to explore the effectiveness of dyad practice compared with individual practice on a simulator for learning a complex clinical skill and (2) to explore medical students' perceptions of how and why dyad practice on a simulator contributes to learning a complex skill. In 2011, the authors randomly assigned 84 medical students to either the dyad or the individual practice group to learn coronary angiography skills using instruction videos and a simulator. Two weeks later, participants each performed two video-recorded coronary angiographies on the simulator. Two raters used a rating scale to assess the participants' video-recorded performance. The authors then interviewed the participants in the dyad practice group. Seventy-two (86%) participants completed the study. The authors found no significant difference between the performance scores of the two groups (mean±standard deviation, 68%±13% for individual versus 63%±16% for dyad practice; P=.18). Dyad practice participants noted that several key factors contributed to their learning: being equal-level novices, the quality of the cooperation between partners, observational learning and overt communication, social aspects and motivation, and meta-cognition. Dyad practice is more efficient and thus more cost-effective than individual practice and can be used for costly virtual reality simulator training. However, dyad practice may not apply to clinical training involving real patients because learning from errors and overt communication, both keys to dyad practice, do not transfer to clinical practice.

  9. Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm.

    PubMed

    Lee, Ji Won; Kim, Chang Won; Lee, Geewon; Lee, Han Cheol; Kim, Sang-Pil; Choi, Bum Sung; Jeong, Yeon Joo

    2018-02-01

    Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P < 0.001). All Group 1 patients had diagnostic image quality of the aortic wall and left ostium. The MCA significantly improved the image quality of the three main coronary arteries ( P < 0.05). Moreover, per-vessel interpretability improved from 92.3% to 97.1% with the MCA ( P = 0.013). Conclusion Hybrid ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

  10. Pulmonary artery segmentation and quantification in sickle cell associated pulmonary hypertension

    NASA Astrophysics Data System (ADS)

    Linguraru, Marius George; Mukherjee, Nisha; Van Uitert, Robert L.; Summers, Ronald M.; Gladwin, Mark T.; Machado, Roberto F.; Wood, Bradford J.

    2008-03-01

    Pulmonary arterial hypertension is a known complication associated with sickle-cell disease; roughly 75% of sickle cell disease-afflicted patients have pulmonary arterial hypertension at the time of death. This prospective study investigates the potential of image analysis to act as a surrogate for presence and extent of disease, and whether the size change of the pulmonary arteries of sickle cell patients could be linked to sickle-cell associated pulmonary hypertension. Pulmonary CT-Angiography scans from sickle-cell patients were obtained and retrospectively analyzed. Randomly selected pulmonary CT-Angiography studies from patients without sickle-cell anemia were used as negative controls. First, images were smoothed using anisotropic diffusion. Then, a combination of fast marching and geodesic active contours level sets were employed to segment the pulmonary artery. An algorithm based on fast marching methods was used to compute the centerline of the segmented arteries. From the centerline, the diameters at the pulmonary trunk and first branch of the pulmonary arteries were measured automatically. Arterial diameters were normalized to the width of the thoracic cavity, patient weight and body surface. Results show that the pulmonary trunk and first right and left pulmonary arterial branches at the pulmonary trunk junction are significantly larger in diameter with increased blood flow in sickle-cell anemia patients as compared to controls (p values of 0.0278 for trunk and 0.0007 for branches). CT with image processing shows great potential as a surrogate indicator of pulmonary hemodynamics or response to therapy, which could be an important tool for drug discovery and noninvasive clinical surveillance.

  11. Computed Tomography-Derived Fractional Flow Reserve in the Detection of Lesion-Specific Ischemia: An Integrated Analysis of 3 Pivotal Trials.

    PubMed

    Xu, Rende; Li, Chenguang; Qian, Juying; Ge, Junbo

    2015-11-01

    Invasive fractional flow reserve (FFR) is the gold standard for the determination of physiologic stenosis severity and the need for revascularization. FFR computed from standard acquired coronary computed tomographic angiography datasets (FFRCT) is an emerging technology which allows calculation of FFR using resting image data from coronary computed tomographic angiography (CCTA). However, the diagnostic accuracy of FFRCT in the evaluation of lesion-specific myocardial ischemia remains to be confirmed, especially in patients with intermediate coronary stenosis. We performed an integrated analysis of data from 3 prospective, international, and multicenter trials, which assessed the diagnostic performance of FFRCT using invasive FFR as a reference standard. Three studies evaluating 609 patients and 1050 vessels were included. The total calculated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FFRCT were 82.8%, 77.7%, 60.8%, 91.6%, and 79.2%, respectively, for the per-vessel analysis, and 89.4%, 70.5%, 69.7%, 89.7%, and 78.7%, respectively, for the per-patient analysis. Compared with CCTA alone, FFRCT demonstrated significantly improved accuracy (P < 0.001) in detecting lesion-specific ischemia. In patients with intermediate coronary stenosis, FFRCT remained both highly sensitive and specific with respect to the diagnosis of ischemia. In conclusion, FFRCT appears to be a reliable noninvasive alternative to invasive FFR, as it demonstrates high accuracy in the determination of anatomy and lesion-specific ischemia, which justifies the performance of additional randomized controlled trials to evaluate both the clinical benefits and the cost-effectiveness of FFRCT-guided coronary revascularization.

  12. Near-infrared fluorescence image-guidance in plastic surgery: A systematic review.

    PubMed

    Cornelissen, Anouk J M; van Mulken, Tom J M; Graupner, Caitlin; Qiu, Shan S; Keuter, Xavier H A; van der Hulst, René R W J; Schols, Rutger M

    2018-01-01

    Near-infrared fluorescence (NIRF) imaging technique, after administration of contrast agents with fluorescent characteristics in the near-infrared (700-900 nm) range, is considered to possess great potential for the future of plastic surgery, given its capacity for perioperative, real-time anatomical guidance and identification. This study aimed to provide a comprehensive literature review concerning current and potential future applications of NIRF imaging in plastic surgery, thereby guiding future research. A systematic literature search was performed in databases of Cochrane Library CENTRAL, MEDLINE, and EMBASE (last search Oct 2017) regarding NIRF imaging in plastic surgery. Identified articles were screened and checked for eligibility by two authors independently. Forty-eight selected studies included 1166 animal/human subjects in total. NIRF imaging was described for a variety of (pre)clinical applications in plastic surgery. Thirty-two articles used NIRF angiography, i.e., vascular imaging after intravenous dye administration. Ten articles reported on NIRF lymphography after subcutaneous dye administration. Although currently most applied, general protocols for dosage and timing of dye administration for NIRF angiography and lymphography are still lacking. Three articles applied NIRF to detect nerve injury, and another three studies described other novel applications in plastic surgery. Future standard implementation of novel intraoperative optical techniques, such as NIRF imaging, could significantly contribute to perioperative anatomy guidance and facilitate critical decision-making in plastic surgical procedures. Further investigation (i.e., large multicenter randomized controlled trials) is mandatory to establish the true value of this innovative surgical imaging technique in standard clinical practice and to aid in forming consensus on protocols for general use.Level of Evidence: Not ratable.

  13. Lipoprotein (a): a potential biological marker for unruptured intracranial aneurysms.

    PubMed

    Phillips, J; Roberts, G; Bolger, C; el Baghdady, A; Bouchier-Hayes, D; Farrell, M; Collins, P

    1997-05-01

    The diagnosis and treatment of intracranial aneurysms (IAs) prior to rupture reduces the high morbidity and mortality associated with their occurrence. Elevated serum lipoprotein (a) [Lp(a)] level, an independent risk factor for atherogenesis, has been demonstrated in sporadic IA disease (1). The purpose of this study was to assess the degree of correlation between elevated Lp(a) levels and the occurrence of IAs in asymptomatic first degree relatives of index cases from three families exhibiting a familial tendency towards IA development. 25 family members and 41 healthy controls were screened by random serum Lp(a) sampling. All family members received 4-vessel cerebral angiography. Eleven family members were found on angiography to harbour asymptomatic aneurysms and all were successfully treated by surgery. Of these 11, ten had significantly raised serum Lp(a) levels (> 30 mg%). Fourteen family members had negative angiograms. Eight of this latter group, mean age 43.6 +/- 3.8 years, had serum Lp(a) levels above the normal range. Mean Lp(a) levels were 53.7 +/- 1.2 mg% in subjects with aneurysms compared with 22.1 +/- 1.45 mg% in subjects without demonstrable aneurysms and 10.5 +/- 0.48 mg% in the control population. The prevalence of elevated Lp(a) levels in these families and the high degree of association of raised Lp(a) levels with the presence of IAs in several family members warrants follow up of angiographically negative young subjects. We require a case-control study to establish whether particular polymorphisms at the apoprotein (a) gene level are associated with the occurrence of IAs in these families.

  14. 64-MDCT angiography of blunt vascular injuries of the neck.

    PubMed

    Chokshi, Falgun H; Munera, Felipe; Rivas, Luis A; Henry, Robert P; Quencer, Robert M

    2011-03-01

    CT angiography (CTA) using 64-MDCT enables timely evaluation of injuries associated with blunt neck trauma. The purpose of this article is to familiarize the reader with the most frequent CTA signs of blunt vascular injury. CTA is a valuable tool to detect blunt vascular injuries, especially using its multiplanar and 3D reconstruction capabilities.

  15. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    PubMed Central

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  16. A New Anatomic Variation: Coexistence of Both Dandy-Walker Variant and Ophthalmic Artery Originating From Contralateral Internal Carotid Artery.

    PubMed

    Ogul, Hayri; Havan, Nuri; Gedikli, Yusuf; Pirimoglu, Berhan; Kantarci, Mecit

    2016-06-01

    The authors report on 1 patient of variant origin of right ophthalmic artery (OA) from ophthalmic segment of the left internal carotid artery. A 41-year-old man was performed magnetic resonance (MR) imaging and MR angiography. Cerebral MR imaging revealed a Dandy-Walker variant. In MR angiography the authors observed this unusual variant of origin of OA and a complete occlusion of right internal carotid artery. To the authors' knowledge, this is the first patient who has coincidence of both Dandy-Walker variant and origin of OA from contralateral internal carotid artery. Careful observation of MR angiography images with maximum intensity projection is very important for detecting rare vascular variations.

  17. [Radiation exposure of radiologists during angiography: dose measurements outside the lead apron].

    PubMed

    Fischer, H; Przetak, C; Teubert, G; Ewen, K; Mödder, U

    1995-02-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r = 0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons.

  18. PROspective Multicenter Imaging Study for Evaluation of chest pain: rationale and design of the PROMISE trial.

    PubMed

    Douglas, Pamela S; Hoffmann, Udo; Lee, Kerry L; Mark, Daniel B; Al-Khalidi, Hussein R; Anstrom, Kevin; Dolor, Rowena J; Kosinski, Andrzej; Krucoff, Mitchell W; Mudrick, Daniel W; Patel, Manesh R; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Cooper, Lawton

    2014-06-01

    Suspected coronary artery disease (CAD) is one of the most common, potentially life-threatening diagnostic problems clinicians encounter. However, no large outcome-based randomized trials have been performed to guide the selection of diagnostic strategies for these patients. The PROMISE study is a prospective, randomized trial comparing the effectiveness of 2 initial diagnostic strategies in patients with symptoms suspicious for CAD. Patients are randomized to either (1) functional testing (exercise electrocardiogram, stress nuclear imaging, or stress echocardiogram) or (2) anatomical testing with ≥64-slice multidetector coronary computed tomographic angiography. Tests are interpreted locally in real time by subspecialty certified physicians, and all subsequent care decisions are made by the clinical care team. Sites are provided results of central core laboratory quality and completeness assessment. All subjects are followed up for ≥1 year. The primary end point is the time to occurrence of the composite of death, myocardial infarction, major procedural complications (stroke, major bleeding, anaphylaxis, and renal failure), or hospitalization for unstable angina. More than 10,000 symptomatic subjects were randomized in 3.2 years at 193 US and Canadian cardiology, radiology, primary care, urgent care, and anesthesiology sites. Multispecialty community practice enrollment into a large pragmatic trial of diagnostic testing strategies is both feasible and efficient. The PROMISE trial will compare the clinical effectiveness of an initial strategy of functional testing against an initial strategy of anatomical testing in symptomatic patients with suspected CAD. Quality of life, resource use, cost-effectiveness, and radiation exposure will be assessed. Copyright © 2014 Mosby, Inc. All rights reserved.

  19. PROspective Multicenter Imaging Study for Evaluation of Chest Pain: Rationale and Design of the PROMISE Trial

    PubMed Central

    Douglas, Pamela S.; Hoffmann, Udo; Lee, Kerry L.; Mark, Daniel B.; Al-Khalidi, Hussein R.; Anstrom, Kevin; Dolor, Rowena J.; Kosinski, Andrzej; Krucoff, Mitchell W.; Mudrick, Daniel W.; Patel, Manesh R.; Picard, Michael H.; Udelson, James E.; Velazquez, Eric J.; Cooper, Lawton

    2014-01-01

    Background Suspected coronary artery disease (CAD) is one of the most common, potentially life threatening diagnostic problems clinicians encounter. However, no large outcome-based randomized trials have been performed to guide the selection of diagnostic strategies for these patients. Methods The PROMISE study is a prospective, randomized trial comparing the effectiveness of two initial diagnostic strategies in patients with symptoms suspicious for CAD. Patients are randomized to either: 1) functional testing (exercise electrocardiogram, stress nuclear imaging, or stress echocardiogram); or 2) anatomic testing with >=64 slice multidetector coronary computed tomographic angiography. Tests are interpreted locally in real time by subspecialty certified physicians and all subsequent care decisions are made by the clinical care team. Sites are provided results of central core lab quality and completeness assessment. All subjects are followed for ≥1 year. The primary end-point is the time to occurrence of the composite of death, myocardial infarction, major procedural complications (stroke, major bleeding, anaphylaxis and renal failure) or hospitalization for unstable angina. Results Over 10,000 symptomatic subjects were randomized in 3.2 years at 193 US and Canadian cardiology, radiology, primary care, urgent care and anesthesiology sites. Conclusion Multi-specialty community practice enrollment into a large pragmatic trial of diagnostic testing strategies is both feasible and efficient. PROMISE will compare the clinical effectiveness of an initial strategy of functional testing against an initial strategy of anatomic testing in symptomatic patients with suspected CAD. Quality of life, resource use, cost effectiveness and radiation exposure will be assessed. Clinical trials.gov identifier NCT01174550 PMID:24890527

  20. Planning-free cerebral blood flow territory mapping in patients with intracranial arterial stenosis

    PubMed Central

    Arteaga, Daniel F; Strother, Megan K; Davis, L Taylor; Fusco, Matthew R; Faraco, Carlos C; Roach, Brent A; Scott, Allison O

    2016-01-01

    A noninvasive method for quantifying cerebral blood flow and simultaneously visualizing cerebral blood flow territories is vessel-encoded pseudocontinuous arterial spin labeling MRI. However, obstacles to acquiring such information include limited access to the methodology in clinical centers and limited work on how clinically acquired vessel-encoded pseudocontinuous arterial spin labeling data correlate with gold-standard methods. The purpose of this work is to develop and validate a semiautomated pipeline for the online quantification of cerebral blood flow maps and cerebral blood flow territories from planning-free vessel-encoded pseudocontinuous arterial spin labeling MRI with gold-standard digital subtraction angiography. Healthy controls (n = 10) and intracranial atherosclerotic disease patients (n = 34) underwent 3.0 T MRI imaging including vascular (MR angiography) and hemodynamic (cerebral blood flow-weighted arterial spin labeling) MRI. Patients additionally underwent catheter and/or CT angiography. Variations in cross-territorial filling were grouped according to diameters of circle of Willis vessels in controls. In patients, Cohen’s k-statistics were computed to quantify agreement in perfusion patterns between vessel-encoded pseudocontinuous arterial spin labeling and angiography. Cross-territorial filling patterns were consistent with circle of Willis anatomy. The intraobserver Cohen's k-statistics for cerebral blood flow territory and digital subtraction angiography perfusion agreement were 0.730 (95% CI = 0.593–0.867; reader one) and 0.708 (95% CI = 0.561–0.855; reader two). These results support the feasibility of a semiautomated pipeline for evaluating major neurovascular cerebral blood flow territories in patients with intracranial atherosclerotic disease. PMID:27389177

  1. Targeting clinical outcomes: Endovascular simulation improves diagnostic coronary angiography skills.

    PubMed

    Schimmel, Daniel R; Sweis, Ranya; Cohen, Elaine R; Davidson, Charles; Wayne, Diane B

    2016-02-15

    The purpose of this study is to determine the effects of simulation-based medical education (SBME) on the skills required to perform coronary angiography in the cardiac catheterization laboratory. Cardiovascular fellows commonly learn invasive procedures on patients. Because this approach is not standardized, it can result in inconsistent skill acquisition through exclusion of concepts and skills. Also, the learning curve varies between trainees yielding variability in skill acquisition. Therefore, coronary angiography skills are an excellent target for SBME in an environment in which direct patient care is not jeopardized. From January 2013 to June 2013, 14 cardiovascular fellows entering the cardiac catheterization laboratory at a tertiary care teaching hospital were tested on an endovascular simulator to assess baseline skills. All fellows subsequently underwent didactic teaching and preceptor-lead training on the endovascular simulator. Topics included basic catheterization skills and a review of catheterization laboratory systems. Following training, all fellows underwent a post-training assessment on the endovascular simulator. Paired t tests were used to compare items on the skills checklist and simulator defined variables. Cardiovascular fellows scored significantly higher on a diagnostic coronary angiography skills checklist following SBME using an endovascular simulator. The mean pretest score was 66.6% (SD = 9.7%) compared to 86.0% (SD = 6.3%) following simulator training (P < 0.001). Additional findings include significant reduction in procedure time and use of cine-fluoroscopy at posttest. SBME significantly improved cardiovascular fellows' performance of simulated coronary angiography skills. Standardized simulation-based education is a valuable adjunct to traditional clinical education for cardiovascular fellows. © 2015 Wiley Periodicals, Inc.

  2. ULTRAHIGH SPEED SWEPT SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY OF RETINAL AND CHORIOCAPILLARIS ALTERATIONS IN DIABETIC PATIENTS WITH AND WITHOUT RETINOPATHY.

    PubMed

    Choi, WooJhon; Waheed, Nadia K; Moult, Eric M; Adhi, Mehreen; Lee, ByungKun; De Carlo, Talisa; Jayaraman, Vijaysekhar; Baumal, Caroline R; Duker, Jay S; Fujimoto, James G

    2017-01-01

    To investigate the utility of ultrahigh speed, swept source optical coherence tomography angiography in visualizing retinal microvascular and choriocapillaris (CC) changes in diabetic patients. The study was prospective and cross-sectional. A 1,050 nm wavelength, 400 kHz A-scan rate swept source optical coherence tomography prototype was used to perform volumetric optical coherence tomography angiography of the retinal and CC vasculatures in diabetic patients and normal subjects. Sixty-three eyes from 32 normal subjects, 9 eyes from 7 patients with proliferative diabetic retinopathy, 29 eyes from 16 patients with nonproliferative diabetic retinopathy, and 51 eyes from 28 diabetic patients without retinopathy were imaged. Retinal and CC microvascular abnormalities were observed in all stages of diabetic retinopathy. In nonproliferative diabetic retinopathy and proliferative diabetic retinopathy, optical coherence tomography angiography visualized a variety of vascular abnormalities, including clustered capillaries, dilated capillary segments, tortuous capillaries, regions of capillary dropout, reduced capillary density, abnormal capillary loops, and foveal avascular zone enlargement. In proliferative diabetic retinopathy, retinal neovascularization above the inner limiting membrane was visualized. Regions of CC flow impairment in patients with proliferative diabetic retinopathy and nonproliferative diabetic retinopathy were also observed. In 18 of the 51 of eyes from diabetic patients without retinopathy, retinal mircrovascular abnormalities were observed and CC flow impairment was found in 24 of the 51 diabetic eyes without retinopathy. The ability of optical coherence tomography angiography to visualize retinal and CC microvascular abnormalities suggests it may be a useful tool for understanding pathogenesis, evaluating treatment response, and earlier detection of vascular abnormalities in patients with diabetes.

  3. Insufficient platelet inhibition is related to silent embolic cerebral infarctions after coronary angiography.

    PubMed

    Kim, Bum Joon; Lee, Seung-Whan; Park, Seong-Wook; Kang, Dong-Wha; Kim, Jong S; Kwon, Sun U

    2012-03-01

    Considering that insufficient platelet inhibition is related to thrombotic complications after coronary angiography, we hypothesized that the extent of platelet inhibition by antiplatelet agents is related to the occurrence of silent embolic cerebral infarction (SECI) after coronary angiography. Among the patients scheduled for coronary artery bypass surgery, we retrospectively analyzed the location of SECI on diffusion-weighted imaging of 272 patients, which was performed after coronary angiography, as a presurgical evaluation in Phase 1 study. In Phase 2 study, we have prospectively recruited 102 patients to compare the extent of platelet inhibition measured by the VerifyNow system among patients with and without SECI. SECI is observed in 45 patients (16.5%) in Phase 1 and 17 (16.7%) in Phase 2. The lesions were slightly more frequent in the right hemisphere. In the Phase 2 study, aspirin reaction units and P(2)Y(12) reaction units were higher in the patients with SECI than those without (aspirin reaction units: 490±72 versus 446±53, P=0.03; P(2)Y(12) reaction units: 352±65 versus 300±77, P=0.009). The incidence of SECI increased with the number of resistant antiplatelets; resistance to both antiplatelet agent (50%), resistance to 1 antiplatelet agent (22%), and no resistance (4%; P=0.023). From the result of logistic regression, higher aspirin reaction units, white blood cell count, low hemoglobin, and nonresponsiveness to antiplatelet agents were independent risk factors. Insufficient platelet inhibition after administration of antiplatelet agents is related with SECI appearing after coronary angiography.

  4. Vascular Assessment for Transcatheter Aortic Valve Replacement: Intravascular Ultrasound Compared With Computed Tomography.

    PubMed

    Essa, Essa; Makki, Nader; Bittenbender, Peter; Capers, Quinn; George, Barry; Rushing, Gregory; Crestanello, Juan; Boudoulas, Konstantinos Dean; Lilly, Scott M

    2016-12-01

    Assessment of the femoral and iliac arteries is essential prior to transcatheter aortic valve replacement (TAVR). It is critical for establishing candidacy for a femoral approach, and can help predict vascular complications. Although computed tomography angiography (CTA) is the standard imaging modality, it has limitations. This study compared CTA with intravascular ultrasound (IVUS) in patients undergoing TAVR evaluation. Fifteen patients undergoing pre-TAVR coronary angiography and hemodynamic assessment were recruited. Following coronary angiography, patients underwent distal aortography, bilateral iliac and femoral arteriography, and IVUS assessment. Vascular tortuosity, minimum lumen diameter, and cross-sectional area were obtained and the findings were compared with those obtained from CTA. Correlation between IVUS and CTA was strong for minimum luminal diameter (r=0.62). Concordance was also strong between CTA and invasive iliofemoral angiography for assessment of tortuosity (r=0.75). Utilizing Bland-Altman analysis, vessel diameters obtained by IVUS were consistently greater than those obtained by CTA. The angiography and IVUS strategy was associated with a lower overall mean contrast utilization (29 cc vs 100 cc; P<.001), reduced mean radiation exposure (527 mGy vs 998 mGy; P=.045), and no significant difference in mean test duration (13.3 minutes vs 10 minutes; P=.12). For femoral and iliac arterial assessment prior to TAVR, IVUS is a viable alternative to CTA with comparable accuracy, and the potential for less contrast use and less radiation exposure. IVUS is also a valuable adjunct to CTA in patients with borderline femoral access diameters or considerable CTA artifacts.

  5. Changes of choroidal neovascularization in indocyanine green angiography after intravitreal ranibizumab injection.

    PubMed

    Lee, Ji Eun; Kim, Hyun Woong; Lee, Sang Joon; Lee, Joo Eun

    2015-05-01

    To investigate vascular structural changes of choroidal neovascularization (CNV) followed by intravitreal ranibizumab injections using indocyanine green angiography. A total of 31 patients with exudative age-related macular degeneration and CNV whose structures were identifiable in indocyanine green angiography were included. Ranibizumab was injected into the vitreous cavity once a month for 3 months and then as needed for the next 3 months prospectively. Indocyanine green angiography was performed at baseline, 3, and 6 months. Early to midphase images of the indocyanine green angiography in the details of vascular structure of the CNV were discerned the best were used in the image analysis. Vascular structures of CNV were described as arteriovenular and capillary components, and structural changes were assessed. Arteriovenular components were observed in 29 eyes (94%). Regression of the capillary components was observed in most cases. Although regression of arteriovenular component was noted in 14 eyes (48%), complete resolution was not observed. The eyes were categorized into 3 groups according to CNV structural changes: the regressed (Group R, 10 eyes, 31%), the matured (Group M, 7 eyes, 23%), and the growing (Group G, 14 eyes, 45%). In Group R, there was no regrowth of CNV found at 6 months. In Group M, distinct vascular structures were observed at 3 months and persisted without apparent changes at 6 months. In Group G, growth or reperfusion of capillary components from the persisting arteriovenular components was noted at 6 months. Both capillary and arteriovenular components were regressed during monthly ranibizumab injections. However, CNV regrowth was observed in a group of patients during the as-needed treatment phase.

  6. Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?

    PubMed

    Kok, Madeleine; Kietselaer, Bas L J H; Mihl, Casper; Altintas, Sibel; Nijssen, Estelle C; Wildberger, Joachim E; Das, Marco

    2015-01-01

    It is unclear if prolonged contrast media injection, to improve right ventricular visualization during coronary CT angiography, leads to increased detection of right ventricle pathology. The purpose of this study was to evaluate right ventricle enhancement and subsequent detection of right ventricle disease during coronary CT angiography. 472 consecutive patients referred for screening coronary CT angiography were retrospectively evaluated. Every patient underwent multidetector-row CT of the coronary arteries: 128x 0.6mm coll., 100-120kV, rot. time 0.28s, ref. mAs 350 and received an individualized (P3T) contrast bolus injection of iodinated contrast medium (300 mgI/ml). Patient data were analyzed to assess right ventricle enhancement (HU) and right ventricle pathology. Image quality was defined good when right ventricle enhancement >200HU, moderate when 140-200HU and poor when <140HU. Good image quality was found in 372 patients, moderate in 80 patients and poor in 20 patients. Mean enhancement of the right ventricle cavity was 268HU±102. Patients received an average bolus of 108±24 ml at an average peak flow rate of 6.1±2.2 ml/s. In only three out of 472 patients (0.63%) pathology of the right ventricle was found (dilatation) No other right ventricle pathology was detected. Right ventricle pathology was detected in three out of 472 patients; the dilatation observed in these three cases may have been picked up even without dedicated enhancement of the right ventricle. Based on our findings, right ventricle enhancement can be omitted during screening coronary CT angiography.

  7. [Evaluation of diabetic microangiopathy using optical coherence tomography angiography].

    PubMed

    Czakó, Cecília; Sándor, Gábor László; Ecsedy, Mónika; Szepessy, Zsuzsanna; Borbándy, Ágnes; Resch, Miklós; Papp, András; Récsán, Zsuzsa; Horváth, Hajnalka; Nagy, Zoltán Zsolt; Kovács, Illés

    2018-02-01

    Optical coherence tomography angiography is a non-invasive imaging technique that is able to visualize the different retinal vascular layers using motion contrast to detect blood flow without intravenous dye injection. This method might help to assess microangiopathy in diabetic retinopathy during screening and follow-up. To quantify retinal microvasculature alterations in both eyes of diabetic patients in relation to systemic risk factors using optical coherence tomography angiography. Both eyes of 36 diabetic patients and 45 individuals without diabetes were examined. Duration of diabetes, insulin therapy, blood pressure, HbA 1c , dyslipidemia, axial length and the presence of diabetic retinopathy were recorded. Retinal vessel density was measured by optical coherence tomography angiography. The effect of risk factors on vessel density and between-eye asymmetry was assessed using multivariable regression analysis. Vessel density was significantly lower and between-eye difference was significantly higher in diabetic patients compared to controls (p<0.05). Both vessel density and between-eye asymmetry significantly correlated with diabetes duration (p<0.05) after controlling for the effect of risk factors. The between-eye asymmetry in vessel density was significantly higher in patients without clinically detectable diabetic retinopathy compared to control subjects (p<0.001). There is a decrease in retinal vessel density and an increase in between-eye asymmetry in patients with diabetes compared to healthy subjects. By using optical coherence tomography angiography, the detection of these microvascular alterations is possible before clinically detectable diabetic retinopathy and might serve as a useful tool in both screening and timing of treatment. Orv Hetil. 2018; 159(8): 320-326.

  8. Severity of coronary artery disease in obese patients undergoing coronary angiography: "obesity paradox" revisited.

    PubMed

    Niraj, Ashutosh; Pradhan, Jyotiranjan; Pradahan, Jyotiranjan; Fakhry, Hesham; Veeranna, Vikas; Afonso, Luis

    2007-08-01

    Recent studies have highlighted the existence of an 'obesity paradox' in patients undergoing coronary angiography, i.e., a high body mass Index (BMI) is associated with less severe coronary lesions. We sought to confirm the existence of this phenomenon in the US patient population. Study subjects included 770 consecutive patients (470 men, 428 African-Americans, 212 Caucasians) referred for coronary angiography to a tertiary care center. Duke myocardial jeopardy score, a prognostication tool predictive of 1-year mortality in coronary artery disease (CAD) patients, was assigned to angiographic data. Patients were classified according to their BMI (kg/m2) as normal (21-24), overweight (25-29), obesity class I (30-34), class II (35-39) and class III (40 or above). Patients in the increasing obesity class had a higher prevalence of diabetes, hypertension and dyslipidemia and were more likely to be women. A negative correlation was observed between BMI and age (R = - 0.15 p < 0.001) as well as between BMI and Duke Jeopardy score (r = - 0.07, p < 0.05) indicating that patients with higher BMI were referred for coronary angiography at a younger age, and had a lower coronary artery disease (CAD) burden. BMI was not an independent predictor of coronary lesion severity on multivariate stepwise linear regression analysis. Obese patients are referred for coronary angiography at an earlier age and have a lower CAD burden lending further credence to the existence of an apparent "obesity paradox". However, obesity per se, after adjustment for comorbidities, is not an independent predictor of severity of coronary artery disease. (c) 2007 Wiley Periodicals, Inc.

  9. Novel device and technique for minimally invasive intracerebral hematoma evacuation in the same setting of a ruptured intracranial aneurysm: combined treatment in the neurointerventional angiography suite.

    PubMed

    Turner, Raymond D; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Spiotta, Alejandro M

    2015-03-01

    The presence of intracerebral hematoma from aneurysm rupture is an indication for craniotomy for clot evacuation and aneurysm clipping. Some centers have begun securing aneurysms with coil embolization followed by clot evacuation in the operating room. This approach requires transporting a patient from the angiography suite to the operating room, which can take valuable time and resources. To report our experience with 3 cases in which a novel technique for minimally invasive evacuation of intracerebral hematomas after endovascular treatment of ruptured intracranial aneurysms was used. The Penumbra Apollo system can be used in the angiography suite in conjunction with neuroendovascular techniques to simultaneously address a symptomatic hematoma associated with a ruptured aneurysm. Standard preoperative computed tomography angiography was performed on arrival to the emergency department. The patients underwent diagnostic cerebral angiography followed by balloon-assisted coil embolization and then remained in the neurointerventional suite for intracerebral hematoma evacuation with the Apollo system. All patients tolerated coil embolization and hematoma evacuation well. The combined procedures lasted <3 hours in both cases. Two patients were eventually discharged to acute rehabilitation facilities less than a month after their initial insult, and 1 has been cleared to return to work. The other patient was transferred to hospice care. The Apollo aspiration system appears to be a safe and effective minimally invasive option for intracerebral hematoma evacuation, particularly when coupled with endovascular embolization of ruptured intracranial aneurysms. Future work will address which patient population is most likely to benefit from this promising technique.

  10. Imaging Foveal Microvasculature: Optical Coherence Tomography Angiography Versus Adaptive Optics Scanning Light Ophthalmoscope Fluorescein Angiography.

    PubMed

    Mo, Shelley; Krawitz, Brian; Efstathiadis, Eleni; Geyman, Lawrence; Weitz, Rishard; Chui, Toco Y P; Carroll, Joseph; Dubra, Alfredo; Rosen, Richard B

    2016-07-01

    To compare the use of optical coherence tomography angiography (OCTA) and adaptive optics scanning light ophthalmoscope fluorescein angiography (AOSLO FA) for characterizing the foveal microvasculature in healthy and vasculopathic eyes. Four healthy controls and 11 vasculopathic patients (4 diabetic retinopathy, 4 retinal vein occlusion, and 3 sickle cell retinopathy) were imaged with OCTA and AOSLO FA. Foveal perfusion maps were semiautomatically skeletonized for quantitative analysis, which included foveal avascular zone (FAZ) metrics (area, perimeter, acircularity index) and vessel density in three concentric annular regions of interest. On each set of OCTA and AOSLO FA images, matching vessel segments were used for lumen diameter measurement. Qualitative image comparisons were performed by visual identification of microaneurysms, vessel loops, leakage, and vessel segments. Adaptive optics scanning light ophthalmoscope FA and OCTA showed no statistically significant differences in FAZ perimeter, acircularity index, and vessel densities. Foveal avascular zone area, however, showed a small but statistically significant difference of 1.8% (P = 0.004). Lumen diameter was significantly larger on OCTA (mean difference 5.7 μm, P < 0.001). Microaneurysms, fine structure of vessel loops, leakage, and some vessel segments were visible on AOSLO FA but not OCTA, while blood vessels obscured by leakage were visible only on OCTA. Optical coherence tomography angiography is comparable to AOSLO FA at imaging the foveal microvasculature except for differences in FAZ area, lumen diameter, and some qualitative features. These results, together with its ease of use, short acquisition time, and avoidance of potentially phototoxic blue light, support OCTA as a tool for monitoring ocular pathology and detecting early disease.

  11. MRI and magnetic resonance angiography findings in patients with multiple sclerosis mimicked by stroke.

    PubMed

    Khedr, Abdullatif Al; Canaple, Sandrine; Monet, Pauline; Godefroy, Olivier; Bugnicourt, Jean-Marc

    2013-08-01

    We report a 45-year-old woman who presented with a first demyelinating event with abnormalities seen on both MRI and magnetic resonance angiography that were highly suggestive of acute ischemic stroke. This report highlights the problem of differential diagnosis of acute neurological symptoms in adult subjects. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavagna, Enrico; D'Andrea, Paolo; Schiavon, Francesco

    Purpose: To evaluate failing hemodialysis arteriovenous fistulas with helical CT angiography (CTA), MR angiography (MRA), and digital subtraction angiography (DSA), and to compare the efficacy of the three techniques in detecting the number, location, grade, and extent of stenoses and in assessing the technical results of percutaneous transluminal angioplasty (PTA) and stenting.Methods: Thirteen patients with Brescia-Cimino arteriovenous fistula malfunction underwent MRA and CTA of the fistula and, within 1 week, DSA. A total of 11 PTAs were performed; in three cases an MR-compatible stent was placed. DSA served as the gold standard for comparison in all patients. The presence, site,more » and number of stenoses or occlusions and the technical results of percutaneous procedures were assessed with DSA, CTA, and MRA.Results: MRA underestimated a single stenosis in one patient; CTA and MRA did not overestimate any stenosis. Significant artifacts related to stent geometry and/or underlying metal were seen in MRA sequences in two cases.Conclusions: CT and MRI can provide information regarding the degree of vascular impairment, helping to stratify patients into those who can have PTA (single or multiple stenoses) versus those who require an operative procedure (occlusion). Conventional angiography can be reserved for candidates for percutaneous intervention.« less

  13. [Radioisotopic mapping of the arrhythmogenic focus in patients with chronic chagasic cardiomyopathy and sustained ventricular tachycardia].

    PubMed

    de Paola, A A; Balbão, C E; Castiglioni, M L; Barbieri, A; Mendonça, A; Netto, O S; Guiguer Júnior, N; Vattimo, A C; Souza, I A; Portugal, O P

    1993-06-01

    To localize the site of the origin of sustained ventricular tachycardia in chronic chagasic cardiomyopathy patients refractory to antiarrhythmic therapy by radionuclide angiography techniques. Five patients underwent radionuclide angiography by intravenous administration of 25mCi 99mTc. The images were obtained in sinus rhythm and during sustained ventricular tachycardia induced in the electrophysiologic laboratory for endocardial mapping. Amplitude and phase images were obtained resulting in a contraction wave synchronic to ventricular dispolarization. All patients had haemodynamic stability during the arrhythmia. One patient had incessant ventricular tachycardia. Mean ejection fraction was 0.38. In 4 patients the site of the origin of ventricular tachycardia was posterior and in one it was localized in the interventricular septum. There was identity in the site of the origin of ventricular tachycardia obtained by endocardial mapping or radionuclide angiography in all patients. The therapy was chemical ablation in 3 patients, surgical aneurysmectomy in one and pharmacologic therapy in the last patient. The site of the origin of ventricular tachycardia can be estimated by analyzing the contraction wave obtained by radionuclide angiography techniques in patients with hemodynamic stable sustained ventricular tachycardia.

  14. Multiresolution image registration in digital x-ray angiography with intensity variation modeling.

    PubMed

    Nejati, Mansour; Pourghassem, Hossein

    2014-02-01

    Digital subtraction angiography (DSA) is a widely used technique for visualization of vessel anatomy in diagnosis and treatment. However, due to unavoidable patient motions, both externally and internally, the subtracted angiography images often suffer from motion artifacts that adversely affect the quality of the medical diagnosis. To cope with this problem and improve the quality of DSA images, registration algorithms are often employed before subtraction. In this paper, a novel elastic registration algorithm for registration of digital X-ray angiography images, particularly for the coronary location, is proposed. This algorithm includes a multiresolution search strategy in which a global transformation is calculated iteratively based on local search in coarse and fine sub-image blocks. The local searches are accomplished in a differential multiscale framework which allows us to capture both large and small scale transformations. The local registration transformation also explicitly accounts for local variations in the image intensities which incorporated into our model as a change of local contrast and brightness. These local transformations are then smoothly interpolated using thin-plate spline interpolation function to obtain the global model. Experimental results with several clinical datasets demonstrate the effectiveness of our algorithm in motion artifact reduction.

  15. New Ways to Detect Pediatric Sickle Cell Retinopathy: A Comprehensive Review.

    PubMed

    Pahl, Daniel A; Green, Nancy S; Bhatia, Monica; Chen, Royce W S

    2017-11-01

    Sickle retinopathy reflects disease-related vascular injury of the eye, which can potentially result in visual loss from vitreous hemorrhage or retinal detachment. Here we review sickle retinopathy among children with sickle cell disease, describe the epidemiology, pediatric risk factors, pathophysiology, ocular findings, and treatment. Newer, more sensitive ophthalmological imaging modalities are available for retinal imaging, including ultra-widefield fluorescein angiography, spectral-domain optical coherence tomography, and optical coherence tomography angiography. Optical coherence tomography angiography provides a noninvasive view of retinal vascular layers that could previously not be imaged and can be quantified for comparative or prospective analyses. Ultra-widefield fluorescein angiography provides a more comprehensive view of the peripheral retina than traditional imaging techniques. Screening for retinopathy by standard fundoscopic imaging modalities detects a prevalence of approximately 10%. In contrast, these more sensitive methods allow for more sensitive examination that includes the retina perimeter where sickle retinopathy is often first detectable. Use of these new imaging modalities may detect a higher prevalence of early sickle pathology among children than has previously been reported. Earlier detection may help in better understanding the pathogenesis of sickle retinopathy and guide future screening and treatment paradigms.

  16. Optical coherence tomography angiography retinal vascular network assessment in multiple sclerosis.

    PubMed

    Lanzillo, Roberta; Cennamo, Gilda; Criscuolo, Chiara; Carotenuto, Antonio; Velotti, Nunzio; Sparnelli, Federica; Cianflone, Alessandra; Moccia, Marcello; Brescia Morra, Vincenzo

    2017-09-01

    Optical coherence tomography (OCT) angiography is a new method to assess the density of the vascular networks. Vascular abnormalities are considered involved in multiple sclerosis (MS) pathology. To assess the presence of vascular abnormalities in MS and to evaluate their correlation to disease features. A total of 50 MS patients with and without history of optic neuritis (ON) and 46 healthy subjects were included. All underwent spectral domain (SD)-OCT and OCT angiography. Clinical history, Expanded Disability Status Scale (EDSS), Multiple Sclerosis Severity Score (MSSS) and disease duration were collected. Angio-OCT showed a vessel density reduction in eyes of MS patients when compared to controls. A statistically significant reduction in all SD-OCT and OCT angiography parameters was noticed both in eyes with and without ON when compared with control eyes. We found an inverse correlation between SD-OCT parameters and MSSS ( p = 0.003) and between vessel density parameters and EDSS ( p = 0.007). We report a vessel density reduction in retina of MS patients. We highlight the clinical correlation between vessel density and EDSS, suggesting that angio-OCT could be a good marker of disease and of disability in MS.

  17. Comparison between optical coherence tomography angiography and fluorescein angiography findings in retinal vasculitis.

    PubMed

    Abucham-Neto, Julio Zaki; Torricelli, André Augusto Miranda; Lui, Aline Cristina Fioravanti; Guimarães, Sarah Napoli; Nascimento, Heloisa; Regatieri, Caio Vinícius

    2018-01-01

    To describe optical coherence tomography angiography (OCT-A) findings in patients with retinal vasculitis and to compare them to current fluorescein angiography (FA) findings. This was an observational case series. Nineteen eyes in 10 patients with retinal vasculitis of various etiologies were imaged with FA (TRC-50DX, Topcon) and OCT-A (SD-OCT, Optovue). The images were reviewed and analyzed. The mean age was 36 years (range 24-67 years); there were three males and seven females. The primary vessels involved were veins (89%). Fourteen eyes (74%) had active inflammatory disease during the study period, with signs of vascular sheathing and perivascular leakage on FA. Interestingly, in this group, OCT-A was not able to detect clear signs of active inflammation around the affected vessels. Nevertheless, OCT-A was able to detect secondary lesions in fourteen eyes (74%), including some findings not clearly shown on FA. Most of these were within the macular area. OCT-A was particularly effective in cases of capillary dropout, increased foveal avascular zone, telangiectasias, shunts, and areas of neovascularization. FA remains an essential complementary exam for detection of retinal vasculitis. However, OCT-A extends FA findings and affords better assessment of secondary complications.

  18. Assessment of physician and patient (child and adult) equivalent doses during renal angiography by Monte Carlo method.

    PubMed

    Karimian, A; Nikparvar, B; Jabbari, I

    2014-11-01

    Renal angiography is one of the medical imaging methods in which patient and physician receive high equivalent doses due to long duration of fluoroscopy. In this research, equivalent doses of some radiosensitive tissues of patient (adult and child) and physician during renal angiography have been calculated by using adult and child Oak Ridge National Laboratory phantoms and Monte Carlo method (MCNPX). The results showed, in angiography of right kidney in a child and adult patient, that gall bladder with the amounts of 2.32 and 0.35 mSv, respectively, has received the most equivalent dose. About the physician, left hand, left eye and thymus absorbed the most amounts of doses, means 0.020 mSv. In addition, equivalent doses of the physician's lens eye, thyroid and knees were 0.023, 0.007 and 7.9E-4 mSv, respectively. Although these values are less than the reported thresholds by ICRP 103, it should be noted that these amounts are related to one examination. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire.

    PubMed

    Jiang, Yuhua; Liu, Keyun; Li, Youxiang

    2018-01-01

    To evaluate the feasibility and safety of the robot of endovascular treatment (RobEnt) in clinical practice, we carried out a cerebral angiography using this robot system. We evaluated the performance of application of the robot system to clinical practice through using this robotic system to perform the digital subtraction angiography for a patient who was suspected of suffering intracranial aneurysm. At the same time, through comparing the postoperative head nuclear magnetic and blood routine with the preoperative examination, we evaluated the safety of application of the robot system to clinical practice. We performed the robot system to complete the bilateral carotid artery and bilateral vertebral arteriography. The results indicate that there was no obvious abnormality in the patient's cerebral artery. No obvious abnormality was observed in the examination of patients' check-up, head nuclear magnetism, and blood routine after the digital subtraction angiography. From this clinical trial, it can be observed that the robot system can perform the operation of cerebral angiography. The robot system can basically complete the related observation indexes, and its accuracy, effectiveness, stability, and safety basically meet the requirements of clinical application in neurointerventional surgery.

  20. Spinal arteriovenous shunts: accuracy of shunt detection, localization, and subtype discrimination using spinal magnetic resonance angiography and manual contrast injection using a syringe.

    PubMed

    Unsrisong, Kittisak; Taphey, Siriporn; Oranratanachai, Kanokporn

    2016-04-01

    The object of this study was to evaluate the accuracy of fast 3D contrast-enhanced spinal MR angiography (MRA) using a manual syringe contrast injection technique for detecting and evaluating spinal arteriovenous shunts (AVSs). This was a retrospective study of 15 patients and 20 spinal MRA and catheter angiography studies. The accuracy of using spinal MRA to detect spinal AVS, localize shunts, and discriminate the subtype and dominant arterial feeder of the AVS were studied. There were 14 pretherapeutic and 6 posttherapeutic follow-up spinal MRA and catheter spinal angiography studies. The spinal AVS was demonstrated in 17 of 20 studies. Spinal MRA demonstrated 100% sensitivity for detecting spinal AVS with no false-negative results. A 97% accuracy rate for AVS subtype discrimination and shunt level localization was achieved using this study's diagnostic criteria. The detection of the dominant arterial feeder was limited to 9 of these 17 cases (53%). The fast 3D contrast-enhanced MRA technique performed using manual syringe contrast injection can detect the presence of a spinal AVS, locate the shunt level, and discriminate AVS subtype in most cases, but is limited when detecting small arterial feeders.

  1. A randomized trial comparing primary angioplasty versus stent placement for symptomatic intracranial stenosis

    PubMed Central

    Qureshi, Adnan I; Chaudhry, Saqib A; Siddiq, Farhan; Majidi, Shahram; Rodriguez, Gustavo J; Suri, M Fareed K

    2013-01-01

    Background: Both primary angioplasty alone and angioplasty with a self-expanding stent have been compared in non-randomized concurrent clinical studies that suggest equivalent results. However, there is no randomized trial that has compared the two procedures in patients with symptomatic high grade intracranial stenosis. Objective: The primary aim of the randomized trial was to compare the clinical and angiographic efficacy of primary angioplasty and angioplasty followed by stent placement in preventing restenosis, stroke, requirement for second treatment, and death in patients with symptomatic intracranial stenosis. Methods: The study prospectively evaluated efficacy and safety of the two existing neurointerventional techniques for treatment of moderate intracranial stenosis (stenosis ≥ 50%) with documented failure of medical treatment or severe stenosis (≥70%) with or without failure of medical treatment. Results: A total of 18 patients were recruited in the study (mean age [±SD] was 64.7 ± 15.1 years); out of these, 12 were men. Of these 18, 10 were treated with primary angioplasty and 8 were treated with angioplasty followed by self-expanding stent. The technical success rates of intracranial angioplasty and stent placements defined as ability to achieve <30% residual stenosis when assessed by immediate post-procedure angiography was 5 of 10 and 5 of 8 patients, respectively. The total fluoroscopic time (mean [±SD]) was lower in patients undergoing primary angioplasty 37 [±11] min versus those undergoing angioplasty followed by self-expanding stent 42 [±15] min, P = 0.4321. The stroke and death rate within 1 month was very low in both patient groups (1 of 10 versus 0 of 8 patients). One patient randomized to stent placement continued to have recurrent ischemic symptoms requiring another angioplasty in the vertebral artery on post-procedure Day 2. Conclusions: The trial suggests that a randomized trial comparing primary angioplasty to angioplasty followed by stent placement is feasible. The immediate procedural outcomes with primary angioplasty are comparable to stent placement and warrant further studies. PMID:24358415

  2. Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

    PubMed

    Saade, Charbel; Deeb, Ibrahim Alsheikh; Mohamad, Maha; Al-Mohiy, Hussain; El-Merhi, Fadi

    2016-01-01

    Over the last decade, exponential advances in computed tomography (CT) technology have resulted in improved spatial and temporal resolution. Faster image acquisition enabled renal CT angiography to become a viable and effective noninvasive alternative in diagnosing renal vascular pathologies. However, with these advances, new challenges in contrast media administration have emerged. Poor synchronization between scanner and contrast media administration have reduced the consistency in image quality with poor spatial and contrast resolution. Comprehensive understanding of contrast media dynamics is essential in the design and implementation of contrast administration and image acquisition protocols. This review includes an overview of the parameters affecting renal artery opacification and current protocol strategies to achieve optimal image quality during renal CT angiography with iodinated contrast media, with current safety issues highlighted.

  3. Combined multi-modal photoacoustic tomography, optical coherence tomography (OCT) and OCT angiography system with an articulated probe for in vivo human skin structure and vasculature imaging

    PubMed Central

    Liu, Mengyang; Chen, Zhe; Zabihian, Behrooz; Sinz, Christoph; Zhang, Edward; Beard, Paul C.; Ginner, Laurin; Hoover, Erich; Minneman, Micheal P.; Leitgeb, Rainer A.; Kittler, Harald; Drexler, Wolfgang

    2016-01-01

    Cutaneous blood flow accounts for approximately 5% of cardiac output in human and plays a key role in a number of a physiological and pathological processes. We show for the first time a multi-modal photoacoustic tomography (PAT), optical coherence tomography (OCT) and OCT angiography system with an articulated probe to extract human cutaneous vasculature in vivo in various skin regions. OCT angiography supplements the microvasculature which PAT alone is unable to provide. Co-registered volumes for vessel network is further embedded in the morphologic image provided by OCT. This multi-modal system is therefore demonstrated as a valuable tool for comprehensive non-invasive human skin vasculature and morphology imaging in vivo. PMID:27699106

  4. Noninvasive Fractional Flow Reserve Derived From Coronary CT Angiography: Clinical Data and Scientific Principles.

    PubMed

    Min, James K; Taylor, Charles A; Achenbach, Stephan; Koo, Bon Kwon; Leipsic, Jonathon; Nørgaard, Bjarne L; Pijls, Nico J; De Bruyne, Bernard

    2015-10-01

    Fractional flow reserve derived from coronary computed tomography angiography enables noninvasive assessment of the hemodynamic significance of coronary artery lesions and coupling of the anatomic severity of a coronary stenosis with its physiological effects. Since its initial demonstration of feasibility of use in humans in 2011, a significant body of clinical evidence has developed to evaluate the diagnostic performance of coronary computed tomography angiography-derived fractional flow reserve compared with an invasive fractional flow reserve reference standard. The purpose of this paper was to describe the scientific principles and to review the clinical data of this technology recently approved by the U.S. Food and Drug Administration. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Aberrant systemic arterial supply to normal lung arising from the proper hepatic artery discovered during transarterial chemoembolization.

    PubMed

    Walsworth, Matthew K; Yap, Felix Y; McWilliams, Justin P

    2015-11-01

    We report a rare case of dual arterial supply to an otherwise normal lung discovered incidentally during initial angiography performed with the intent of chemoembolization of hepatocellular carcinoma. In addition to normal hepatic arterial supply, the proper hepatic artery provided systemic arterial supply to the lower lobe of the left lung. Subsequent chest computed tomography angiography demonstrated a normal tracheobronchial tree and normal pulmonary arterial supply to the lung. Although other anatomic variants have been reported, there are no other reported cases of systemic arterial supply from the proper hepatic artery to the lung. Identifying systemic arterial supply to the lung during angiography is important while performing transcatheter chemoembolization or radioembolization in the liver in order to minimize non-target embolization of the lung.

  6. Types of diaphragmatic motion during hepatic angiography.

    PubMed

    Katsuda, T; Kuroda, C; Fujita, M

    1997-01-01

    To determine the types and causes of diaphragmatic motion during hepatic angiography, the authors used transarterial cut-film portography (TAP) to study movement of the diaphragm during breath-holding. Thirty-three TAP sequences were studied, and the patients' diaphragmatic motions were classified into four categories according to the distance their diaphragms moved. Results showed that the diaphragm was stationary in 33% of the TAP studies, while perpetual motion occurred in 15% of the studies, early-phase motion occurred in 12% and late-phase motion occurred in 40%. Ten sequences showed diaphragmatic motion of more than 10 mm, with eight sequences showing caudal motion and two showing cranial motion. This article discusses the cause of diaphragmatic motion during breath-holding for hepatic angiography and presents suggestions to reduce motion artifacts during the exam.

  7. Diagnostic utility, safety, and cost-effectiveness of emergency department-initiated early scheduled technetium-99m single photon emission computed tomography imaging followed by expedited outpatient cardiac clinic visits in acute chest pain syndromes.

    PubMed

    Wong, Raymond C; Sinha, Arvind Kumar; Mahadevan, Malcolm; Yeo, Tiong Cheng

    2010-09-01

    Conventional emergency department (EMD) approach to triaging acute chest pain syndromes may lead to unnecessary admissions, resulting to in-hospital bed occupancy and increased healthcare costs. We explore the diagnostic utility of early (less than a week) outpatient scheduled single photon emission computed tomography (SPECT) in intermediate-risk chest pain subjects who presented to EMD with non-diagnostic electrocardiogram and negative serum troponin level. Additionally, we intend to study the safety and cost-effectiveness of such a strategy. We conduct a prospective, non-randomized study of 108 subjects who fit the inclusion criteria. After SPECT studies, all subjects were evaluated in the cardiac clinic within 2 weeks of EMD visits. Final diagnosis of coronary artery disease and subsequent disposition to standard medical therapy or follow-on angiography were decided by incorporating pre-test clinical data and SPECT results. Adverse events defined as myocardial infarction and cardiac death was tracked between EMD visit and eventual therapy (either medical therapy or coronary revascularization). Finally, cost-effectiveness was determined based on estimated cost and days of hospitalization saved between standard strategies of ward admission for further evaluation versus the present early outpatient SPECT-based workflow. Among 108 subjects (mean age 58 years, 59% male) included for analysis, 82 (76%) had normal perfusion status. There was no statistical difference in baseline characteristics and prior ischemic heart disease history between groups. In the 26 abnormal perfusion subjects, seven had follow-on coronary angiography in which three were found to have significant stenotic coronary lesions, but only one had intervention performed. There was an unscheduled coronary angiography in the normal perfusion group that yielded normal coronary anatomy. There was no adverse clinical event in both groups. Compared with standard strategy, early outpatient SPECT initiated by EMD physicians followed by cardiac clinic evaluation resulted in 2.9 days of hospitalization or $781.23 saved per patient per EMD visit. EMD-initiated early SPECT studies followed by cardiac clinic evaluation in intermediate-risk acute chest pain syndromes with non-diagnostic ECG and negative serum troponin levels carries excellent diagnostic and therapeutic utility, in addition to being safe and cost-effective.

  8. Pioglitazone decreases coronary artery inflammation in impaired glucose tolerance and diabetes mellitus: evaluation by FDG-PET/CT imaging.

    PubMed

    Nitta, Yoshikazu; Tahara, Nobuhiro; Tahara, Atsuko; Honda, Akihiro; Kodama, Norihiro; Mizoguchi, Minori; Kaida, Hayato; Ishibashi, Masatoshi; Hayabuchi, Naofumi; Ikeda, Hisao; Yamagishi, Sho-ichi; Imaizumi, Tsutomu

    2013-11-01

    The aim of this study was to compare the effect of pioglitazone with glimepiride on coronary arterial inflammation with serial (18)F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) combined with computed tomography (CT) angiography. Recent studies have shown that FDG-PET combined with CT is a reliable tool to visualize and quantify vascular inflammation. Although pioglitazone significantly prevented the progression of coronary atherosclerosis and reduced the recurrence of myocardial infarction in patients with type 2 diabetes mellitus (DM), it remains unclear whether pioglitazone could attenuate coronary artery inflammation. Fifty atherosclerotic patients with impaired glucose tolerance or type 2 DM underwent determination of blood chemistries, anthropometric and inflammatory variables, and FDG-PET/CT angiography, and then were randomized to receive either pioglitazone or glimepiride for 16 weeks. Effects of the treatments on vascular inflammation of the left main trunk were evaluated by FDG-PET/CT angiography at baseline and end of the study. Vascular inflammation of the left main trunk was measured by blood-normalized standardized uptake value, known as a target-to-background ratio. Three patients dropped out of the study during the assessment or treatment. Finally, 25 pioglitazone-treated patients and 22 glimepiride-treated patients (37 men; mean age: 68.1 ± 8.3 years; glycosylated hemoglobin: 6.72 ± 0.70%) completed the study. After 16-week treatments, fasting plasma glucose and glycosylated hemoglobin values were comparably reduced in both groups. Changes in target-to-background ratio values from baseline were significantly greater in the pioglitazone group than in the glimepiride group (-0.12 ± 0.06 vs. 0.09 ± 0.07, p = 0.032), as well as changes in high-sensitivity C-reactive protein (pioglitazone vs. glimepiride group: median: -0.24 [interquartile range (IQR): -1.58 to -0.04] mg/l vs. 0.08 [IQR: -0.07 to 0.79] mg/l, p = 0.031). Our study indicated that pioglitazone attenuated left main trunk inflammation in patients with impaired glucose tolerance or DM in a glucose-lowering independent manner, suggesting that pioglitazone may protect against cardiac events in patients with impaired glucose tolerance or DM by suppressing coronary inflammation. (Anti-Inflammatory Effects of Pioglitazone; NCT00722631). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Coronary CT Angiography Incorporating Doppler-Guided Prospective ECG Gating in Patients with High Heart Rate: Comparison with Results of Traditional Prospective ECG Gating

    PubMed Central

    Li, Min; Yu, Bing-bing; Wu, Jian-hua; Xu, Lin; Sun, Gang

    2013-01-01

    Purpose As Doppler ultrasound has been proven to be an effective tool to predict and compress the optimal pulsing windows, we evaluated the effective dose and diagnostic accuracy of coronary CT angiography (CTA) incorporating Doppler-guided prospective electrocardiograph (ECG) gating, which presets pulsing windows according to Doppler analysis, in patients with a heart rate >65 bpm. Materials and Methods 119 patients with a heart rate >65 bpm who were scheduled for invasive coronary angiography were prospectively studied, and patients were randomly divided into traditional prospective (n = 61) and Doppler-guided prospective (n = 58) ECG gating groups. The exposure window of traditional prospective ECG gating was set at 30%–80% of the cardiac cycle. For the Doppler group, the length of diastasis was analyzed by Doppler. For lengths greater than 90 ms, the pulsing window was preset during diastole (during 60%–80%); otherwise, the optimal pulsing intervals were moved from diastole to systole (during 30%–50%). Results The mean heart rates of the traditional ECG and the Doppler-guided group during CT scanning were 75.0±7.7 bpm (range, 66–96 bpm) and 76.5±5.4 bpm (range: 66–105 bpm), respectively. The results indicated that whereas the image quality showed no significant difference between the traditional and Doppler groups (P = 0.42), the radiation dose of the Doppler group was significantly lower than that of the traditional group (5.2±3.4mSv vs. 9.3±4.5mSv, P<0.001). The sensitivities of CTA applying traditional and Doppler-guided prospective ECG gating to diagnose stenosis on a segment level were 95.5% and 94.3%, respectively; specificities 98.0% and 97.1%, respectively; positive predictive values 90.7% and 88.2%, respectively; negative predictive values 99.0% and 98.7%, respectively. There was no statistical difference in concordance between the traditional and Doppler groups (P = 0.22). Conclusion Doppler-guided prospective ECG gating represents an improved method in patients with a high heart rate to reduce effective radiation doses, while maintaining high diagnostic accuracy. PMID:23696793

  10. The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test disease probability.

    PubMed

    Knuuti, Juhani; Ballo, Haitham; Juarez-Orozco, Luis Eduardo; Saraste, Antti; Kolh, Philippe; Rutjes, Anne Wilhelmina Saskia; Jüni, Peter; Windecker, Stephan; Bax, Jeroen J; Wijns, William

    2018-05-29

    To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD) in which stress electrocardiogram (ECG), stress echocardiography, coronary computed tomography angiography (CCTA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and cardiac magnetic resonance (CMR) can reclassify patients into a post-test probability that defines (>85%) or excludes (<15%) anatomically (defined by visual evaluation of invasive coronary angiography [ICA]) and functionally (defined by a fractional flow reserve [FFR] ≤0.8) significant CAD. A broad search in electronic databases until August 2017 was performed. Studies on the aforementioned techniques in >100 patients with stable CAD that utilized either ICA or ICA with FFR measurement as reference, were included. Study-level data was pooled using a hierarchical bivariate random-effects model and likelihood ratios were obtained for each technique. The PTP ranges for each technique to rule-in or rule-out significant CAD were defined. A total of 28 664 patients from 132 studies that used ICA as reference and 4131 from 23 studies using FFR, were analysed. Stress ECG can rule-in and rule-out anatomically significant CAD only when PTP is ≥80% (76-83) and ≤19% (15-25), respectively. Coronary computed tomography angiography is able to rule-in anatomic CAD at a PTP ≥58% (45-70) and rule-out at a PTP ≤80% (65-94). The corresponding PTP values for functionally significant CAD were ≥75% (67-83) and ≤57% (40-72) for CCTA, and ≥71% (59-81) and ≤27 (24-31) for ICA, demonstrating poorer performance of anatomic imaging against FFR. In contrast, functional imaging techniques (PET, stress CMR, and SPECT) are able to rule-in functionally significant CAD when PTP is ≥46-59% and rule-out when PTP is ≤34-57%. The various diagnostic modalities have different optimal performance ranges for the detection of anatomically and functionally significant CAD. Stress ECG appears to have very limited diagnostic power. The selection of a diagnostic technique for any given patient to rule-in or rule-out CAD should be based on the optimal PTP range for each test and on the assumed reference standard.

  11. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease.

    PubMed

    Malik, Archana; Hellinger, Jeffrey C; Servaes, Sabah; Schwartz, Mathew C; Keller, Marc S; Epelman, Monica

    2017-03-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with congenital heart disease who undergo CT angiography. Based upon our study population, if a child with congenital heart disease has a CT angiography, five out of six will have non-cardiovascular findings, while nearly three out of four (73.7%; 221 / 300) will have significant non-cardiovascular findings. Close attention to the non-cardiovascular structures in children with congenital heart disease presenting for a CT angiography is recommended as in nearly 40% of these children, findings were unexpected and directly altered patient care.

  12. Transcatheter Arterial Embolization Therapy for a Hypoplastic Pelvic Kidney with a Single Vaginal Ectopic Ureter to Control Incontinence: The Usefulness of Three-Dimensional CT Angiography Using Multidetector-Row Helical CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kudoh, Kouichi, E-mail: cdk70770@par.odn.ne.jp; Kadota, Masataka; Nakayama, Yoshiharu

    2003-09-15

    A girl with continuous urinary incontinence was successfully treated by angiographic embolization of a hypoplastic pelvic kidney with a single unilateral vaginal ectopic opening of the ureter. For this intervention, CT angiography was useful for detecting the corresponding renal artery of the hypoplastic kidney.

  13. "More may mean less... " the role for simulation-based medical education in the cardiac catheterization laboratory.

    PubMed

    Westerdahl, Daniel E; Henry, Timothy D

    2016-02-15

    Implementation of simulation-based medical education (SBME) can improve cardiovascular fellows' angiography skills and knowledge SBME focused on performing coronary angiography shortened procedure times and decreased the use of cine-fluoroscopy The ACGME mandate and SCAI's Simulation Committee recommendations suggest SBME will play an expanding and integral role in the field of cardiovascular medicine. © 2016 Wiley Periodicals, Inc.

  14. [Preoperative CT angiography for planning free perforator flaps in breast reconstruction].

    PubMed

    Kuekrek, H; Müller, D; Paepke, S; Dobritz, M; Machens, H-G; Giunta, R E

    2011-04-01

    Preoperative Doppler ultrasonography for planning free perforator flaps is widely established to identify preoperatively perforators. The method allows one to localise the penetrating point of the perforator through the abdominal fascia. By this means it is not possible to see the intramuscular course or the position of the perforator in relation to the inferior epigastric artery. Lately the technique of computed tomographic angiography provides an opportunity for visualising the course of perforator vessels in these tissues. This paper summarises our experience with the preoperative CT angiography in our breast centre. Since spring 2009 we have reconstructed the breasts of 44 female patients by using free flaps from the lower abdominal wall. 6 of these were bilateral. In a total number of 50 breast reconstructions we used 23 deep inferior epigastric perforator (DIEP) flaps and 27 muscle-sparing transverse rectus abdominis muscle (TRAM) flaps. In addition to the preoperative ultrasonography, a CT angiography of the lower abdomen was conducted in 29 patients. On average they showed at least 2 perforators on the left as well as right abdominal sides, which could be used as flap vessels based on their signal intensity. Based on their estimated microsurgical dissection complexity, the perforator vessels could be classified into 3 groups: 1) direct perforators of category A with short intramuscular course (39%), 2) perforators with long intramuscular course of category B (50%) and 3) "turn around" perforators of category C, which pass medially around the rectus abdominis (11%). The technique of CT angiography permits a reliable preoperative visualisation of perforators in their entire course and facilitates the selection of the supplying perforator as well as the intraoperative procedure for the surgeon. The suggested classification of perforators into 3 groups simplifies the preoperative assessment of the microsurgical dissection effort. Compared to the commonly used Doppler ultrasonography there are disadvantages like the additional cost factor and the radiation exposure. However, in our experience the more detailed planning increases the safety of flap raising and reduces surgery time, so that we consider CT angiography a positive tool to facilitate free perforator flaps. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Induced apnea enhances image quality and visualization of cardiopulmonary anatomic during contrastenhanced cardiac computerized tomographic angiography in children

    PubMed Central

    Chakravarthy, Murali; Sunilkumar, Gubbihalli; Pargaonkar, Sumant; Hosur, Rajathadri; Harivelam, Chidananda; Kavaraganahalli, Deepak; Srinivasan, Pradeep

    2015-01-01

    Objective: The purpose of our study was to determine the effect of induced apnea on quality of cardiopulmonary structures during computerized tomographic (CT) angiography images in children with congenital heart diseases. Methods: Pediatric patients with congenital heart defects undergoing cardiac CT angiography at our facility in the past 3 years participated in this study. The earlier patients underwent cardiac CT angiography without induced apnea and while, later, apnea was induced in patients, which was followed by electrocardiogram gated cardiac CT angiography. General anesthesia was induced using sleep dose of intravenous propofol. After the initial check CT, on request by the radiologist, apnea was induced by the anesthesiologist by administering 1 mg/kg of intravenous suxamethonium. Soon after apnea ensued, the contrast was injected, and CT angiogram carried out. CT images in the “apnea group” were compared with those in “nonapnea group.” After the completion of the procedure, the patients were mask ventilated with 100% oxygen till the spontaneous ventilation was restored. Results: We studied 46 patients, of whom 36 with apnea and yet another 10 without. The quality of the image, visualization of structures such as cardiac wall, outflow tracts, lung field, aortopulmonary shunts, and coronary arteries were analyzed and subjected to statistical analysis (Mann–Whitney U, Fischer's exact test and Pearson's Chi-square test). In the induced apnea group, overall image quality was considered excellent in 89% (n = 33) of the studies, while in the “no apnea group,” only 30% of studies were excellent. Absent or minimal motion artifacts were seen in a majority of the studies in apnea group (94%). In the nonapnea group, the respiratory and body motion artifacts were severe in 50%, moderate in 30%, and minimal in 20%, but they were significantly lesser in the apnea group. All the studied parameters were statistically significant in the apnea group in contrast to nonapnea group (P < 0.000). Conclusion: The image quality of cardiac CT angiography greatly improves, and motion artifact significantly decreases with the use of induced apnea in pediatrics patients being evaluated for congenital heart disease. This technique poses no additional morbidity of significance. PMID:25849686

  16. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFR(CT): outcome and resource impacts study.

    PubMed

    Douglas, Pamela S; Pontone, Gianluca; Hlatky, Mark A; Patel, Manesh R; Norgaard, Bjarne L; Byrne, Robert A; Curzen, Nick; Purcell, Ian; Gutberlet, Matthias; Rioufol, Gilles; Hink, Ulrich; Schuchlenz, Herwig Walter; Feuchtner, Gudrun; Gilard, Martine; Andreini, Daniele; Jensen, Jesper M; Hadamitzky, Martin; Chiswell, Karen; Cyr, Derek; Wilk, Alan; Wang, Furong; Rogers, Campbell; De Bruyne, Bernard

    2015-12-14

    In symptomatic patients with suspected coronary artery disease (CAD), computed tomographic angiography (CTA) improves patient selection for invasive coronary angiography (ICA) compared with functional testing. The impact of measuring fractional flow reserve by CTA (FFRCT) is unknown. At 11 sites, 584 patients with new onset chest pain were prospectively assigned to receive either usual testing (n = 287) or CTA/FFR(CT) (n = 297). Test interpretation and care decisions were made by the clinical care team. The primary endpoint was the percentage of those with planned ICA in whom no significant obstructive CAD (no stenosis ≥50% by core laboratory quantitative analysis or invasive FFR < 0.80) was found at ICA within 90 days. Secondary endpoints including death, myocardial infarction, and unplanned revascularization were independently and blindly adjudicated. Subjects averaged 61 ± 11 years of age, 40% were female, and the mean pre-test probability of obstructive CAD was 49 ± 17%. Among those with intended ICA (FFR(CT)-guided = 193; usual care = 187), no obstructive CAD was found at ICA in 24 (12%) in the CTA/FFR(CT) arm and 137 (73%) in the usual care arm (risk difference 61%, 95% confidence interval 53-69, P< 0.0001), with similar mean cumulative radiation exposure (9.9 vs. 9.4 mSv, P = 0.20). Invasive coronary angiography was cancelled in 61% after receiving CTA/FFR(CT) results. Among those with intended non-invasive testing, the rates of finding no obstructive CAD at ICA were 13% (CTA/FFR(CT)) and 6% (usual care; P = 0.95). Clinical event rates within 90 days were low in usual care and CTA/FFR(CT) arms. Computed tomographic angiography/fractional flow reserve by CTA was a feasible and safe alternative to ICA and was associated with a significantly lower rate of invasive angiography showing no obstructive CAD. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  17. Differentiation of early from advanced coronary atherosclerotic lesions: systematic comparison of CT, intravascular US, and optical frequency domain imaging with histopathologic examination in ex vivo human hearts.

    PubMed

    Maurovich-Horvat, Pál; Schlett, Christopher L; Alkadhi, Hatem; Nakano, Masataka; Stolzmann, Paul; Vorpahl, Marc; Scheffel, Hans; Tanaka, Atsushi; Warger, William C; Maehara, Akiko; Ma, Shixin; Kriegel, Matthias F; Kaple, Ryan K; Seifarth, Harald; Bamberg, Fabian; Mintz, Gary S; Tearney, Guillermo J; Virmani, Renu; Hoffmann, Udo

    2012-11-01

    To establish an ex vivo experimental setup for imaging coronary atherosclerosis with coronary computed tomographic (CT) angiography, intravascular ultrasonography (US), and optical frequency domain imaging (OFDI) and to investigate their ability to help differentiate early from advanced coronary plaques. All procedures were performed in accordance with local and federal regulations and the Declaration of Helsinki. Approval of the local Ethics Committee was obtained. Overall, 379 histologic cuts from nine coronary arteries from three donor hearts were acquired, coregistered among modalities, and assessed for the presence and composition of atherosclerotic plaque. To assess the discriminatory capacity of the different modalities in the detection of advanced lesions, c statistic analysis was used. Interobserver agreement was assessed with the Cohen κ statistic. Cross sections without plaque at coronary CT angiography and with fibrous plaque at OFDI almost never showed advanced lesions at histopathologic examination (odds ratio [OR]: 0.02 and 0.06, respectively; both P<.0001), while mixed plaque at coronary CT angiography, calcified plaque at intravascular US, and lipid-rich plaque at OFDI were associated with advanced lesions (OR: 2.49, P=.0003; OR: 2.60, P=.002; and OR: 31.2, P<.0001, respectively). OFDI had higher accuracy for discriminating early from advanced lesions than intravascular US and coronary CT angiography (area under the receiver operating characteristic curve: 0.858 [95% confidence interval {CI}: 0.802, 0.913], 0.631 [95% CI: 0.554, 0.709], and 0.679 [95% CI: 0.618, 0.740]; respectively, P<.0001). Interobserver agreement was excellent for OFDI and coronary CT angiography (κ=0.87 and 0.85, respectively) and was good for intravascular US (κ=0.66). Systematic and standardized comparison between invasive and noninvasive modalities for coronary plaque characterization in ex vivo specimens demonstrated that coronary CT angiography and intravascular US are reasonably associated with plaque composition and lesion grading according to histopathologic findings, while OFDI was strongly associated. These data may help to develop initial concepts of sequential imaging strategies to identify patients with advanced coronary plaques. © RSNA, 2012

  18. High spatial resolution time-resolved magnetic resonance angiography of lower extremity tumors at 3T

    PubMed Central

    Wu, Gang; Jin, Teng; Li, Ting; Morelli, John; Li, Xiaoming

    2016-01-01

    Abstract The aim of this study was to compare diagnostic value of high spatial resolution time-resolved magnetic resonance angiography with interleaved stochastic trajectory (TWIST) using Gadobutrol to Computed tomography angiography (CTA) for preoperative evaluation of lower extremity tumors. This prospective study was approved by the institutional review board. Fifty consecutive patients (31 men, 19 women, age range 18–80 years, average age 42.7 years) with lower extremity tumors underwent TWIST magnetic resonance angiography (MRA) and CTA. Digital subtraction angiography was available for 8 patients. Image quality of MRA was compared with CTA by 2 radiologists according to a 4-point Likert scale. Arterial involvement by tumor was compared using kappa test between MRA and CTA. The ability to identify feeding arteries and arterio-venous fistulae (AVF) was compared using Wilcoxon signed rank test and McNemar test, respectively. Image quality of MRA and CTA was rated without a statistically significant difference (3.88 ± 0.37 vs. 3.97 ± 0.16, P = 0.135). Intramodality agreement was high for the identification of arterial invasion (kappa = 0.806 ± 0.073 for Reader 1, kappa = 0.805 ± 0.073 for Reader 2). Readers found AVF in 27 of 50 MRA cases and 14 of 50 CTA cases (P < 0.001). Mean feeding arteries identified with MRA were significantly more than that with CTA (2.08 ± 1.72 vs. 1.62 ± 1.52, P = .02). TWIST MRA is a reliable imaging modality for the assessment of lower extremity tumors. TWIST MRA is comparable to CTA for the identification of AVF and feeding arteries. PMID:27631262

  19. Dual-Axis Rotational Angiography is Safe and Feasible to Detect Coronary Allograft Vasculopathy in Pediatric Heart Transplant Patients: A Single-Center Experience.

    PubMed

    Rios, Rodrigo; Loomba, Rohit S; Foerster, Susan R; Pelech, Andrew N; Gudausky, Todd M

    2016-04-01

    Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.

  20. Selective Angiography Using the Radiofrequency Catheter: An Alternative Technique for Mapping and Ablation in the Aortic Cusps.

    PubMed

    Roca-Luque, Ivo; Rivas, Nuria; Francisco, Jaume; Perez, Jordi; Acosta, Gabriel; Oristrell, Gerard; Terricabres, Maria; Garcia-Dorado, David; Moya, Angel

    2017-01-01

    Ablation in aortic cusps could be necessary in up to 15% of the patients, especially in para-Hisian atrial tachycardia and ventricular arrhythmias arising from outflow tracts. Risk of coronary damage has led to recommendation of systematic coronary angiography (CA) during the procedure. Other image tests as intravascular (ICE) or transesophageal echocardiography (TEE) have been proposed. Both methods have limitations: additional vascular access for ICE and need for additional CA in some patients in case of TEE. We describe an alternative method to assess relation of catheter tip and coronary ostia during ablation in aortic cusps without additional vascular accesses by performing selective angiography with the ablation catheter. We prospectively evaluated 12 consecutive patients (69.3 ± 8.5, 6 female) who underwent ablation in right (1), left (5), and noncoronary cusps (6). We performed angiography through the ablation cooled tip radiofrequency catheter at the ablation site. Ablation was effective in 91.6% of the patients (3 patients needed additional ablation out of coronary cusps: pulmonary cusp, right ventricular outflow tract (RVOT), and coronary sinus and 1 patient underwent a second procedure because recurrence). No complications occurred neither during procedure nor follow-up (6.2 ± 3.8 months). No technical problems occurred with the ablation catheter after contrast injection. Selective angiography through a cooled-tip radiofrequency ablation catheter is feasible to assess relation of coronary ostia and ablation site when ablation in aortic cusps. It allows continuous real-time assessment of this relation, avoids the need for additional vascular accesses and no complications occurred in our series. © 2016 Wiley Periodicals, Inc.

  1. DETECTION OF MICROVASCULAR CHANGES IN EYES OF PATIENTS WITH DIABETES BUT NOT CLINICAL DIABETIC RETINOPATHY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    de Carlo, Talisa E; Chin, Adam T; Bonini Filho, Marco A; Adhi, Mehreen; Branchini, Lauren; Salz, David A; Baumal, Caroline R; Crawford, Courtney; Reichel, Elias; Witkin, Andre J; Duker, Jay S; Waheed, Nadia K

    2015-11-01

    To evaluate the ability of optical coherence tomography angiography to detect early microvascular changes in eyes of diabetic individuals without clinical retinopathy. Prospective observational study of 61 eyes of 39 patients with diabetes mellitus and 28 control eyes of 22 age-matched healthy subjects that received imaging using optical coherence tomography angiography between August 2014 and March 2015. Eyes with concomitant retinal, optic nerve, and vitreoretinal interface diseases and/or poor-quality images were excluded. Foveal avascular zone size and irregularity, vessel beading and tortuosity, capillary nonperfusion, and microaneurysm were evaluated. Foveal avascular zone size measured 0.348 mm² (0.1085-0.671) in diabetic eyes and 0.288 mm² (0.07-0.434) in control eyes (P = 0.04). Foveal avascular zone remodeling was seen more often in diabetic than control eyes (36% and 11%, respectively; P = 0.01). Capillary nonperfusion was noted in 21% of diabetic eyes and 4% of control eyes (P = 0.03). Microaneurysms and venous beading were noted in less than 10% of both diabetic and control eyes. Both diabetic and healthy control eyes demonstrated tortuous vessels in 21% and 25% of eyes, respectively. Optical coherence tomography angiography was able to image foveal microvascular changes that were not detected by clinical examination in diabetic eyes. Changes to the foveal avascular zone and capillary nonperfusion were more prevalent in diabetic eyes, whereas vessel tortuosity was observed with a similar frequency in normal and diabetic eyes. Optical coherence tomography angiography may be able to detect diabetic eyes at risk of developing retinopathy and to screen for diabetes quickly and noninvasively before the systemic diagnosis is made.

  2. Repeatability of Non-Contrast-Enhanced Lower-Extremity Angiography Using the Flow-Spoiled Fresh Blood Imaging.

    PubMed

    Zhang, Yuyang; Xing, Zhen; She, Dejun; Huang, Nan; Cao, Dairong

    The aim of this study was to prospectively evaluate the repeatability of non-contrast-enhanced lower-extremity magnetic resonance angiography using the flow-spoiled fresh blood imaging (FS-FBI). Forty-three healthy volunteers and 15 patients with lower-extremity arterial stenosis were recruited in this study and were examined by FS-FBI. Digital subtraction angiography was performed within a week after the FS-FBI in the patient group. Repeatability was assessed by the following parameters: grading of image quality, diameter and area of major arteries, and grading of stenosis of lower-extremity arteries. Two experienced radiologists blinded for patient data independently evaluated the FS-FBI and digital subtraction angiography images. Intraclass correlation coefficients (ICCs), sensitivity, and specificity were used for statistical analysis. The grading of image quality of most data was satisfactory. The ICCs for the first and second measures were 0.792 and 0.884 in the femoral segment and 0.803 and 0.796 in the tibiofibular segment for healthy volunteer group, 0.873 and 1.000 in the femoral segment, and 0.737 and 0.737 in the tibiofibular segment for the patient group. Intraobserver and interobserver agreements on diameter and area of arteries were excellent, with ICCs mostly greater than 0.75 in the volunteer group. For stenosis grading analysis, intraobserver ICCs range from 0.784 to 0.862 and from 0.778 to 0.854, respectively. Flow-spoiled fresh blood imaging yielded a mean sensitivity and specificity to detect arterial stenosis or occlusion of 90% and 80% for femoral segment and 86.7% and 93.3% for tibiofibular segment at least. Lower-extremity angiography with FS-FBI is a reliable and reproducible screening tool for lower-extremity atherosclerotic disease, especially for patients with impaired renal function.

  3. PARACENTRAL ACUTE MIDDLE MACULOPATHY IN A PERIVENULAR FERN-LIKE DISTRIBUTION WITH EN FACE OPTICAL COHERENCE TOMOGRAPHY.

    PubMed

    Garrity, Sean T; Tseng, Victoria L; Sarraf, David

    2017-11-22

    To report a case of central retinal vein occlusion resulting in a perivenular pattern of paracentral acute middle maculopathy lesions best identified with en face optical coherence tomography (OCT). Retrospective case report. Optos ultra-widefield fluorescein angiography, spectral domain OCT, en face OCT, and OCT angiography were performed. A 41-year-old man presented with decreased vision in the right eye for 2 weeks. Funduscopic examination of the affected right eye was notable for subtle retinal whitening in the macula, mild retinal venous dilation and tortuosity, and few scattered retinal dot and blot hemorrhages consistent with an acute central retinal vein occlusion. Widefield fluorescein angiography demonstrated delayed arterial and venous filling but no evidence of significant peripheral retinal vascular ischemia. En face OCT segmented at the inner nuclear layer illustrated a remarkable and precise perivenular distribution of fern-like paracentral acute middle maculopathy with periarterial sparing, whereas en face OCT segmented at the outer nuclear layer demonstrated florid cystoid macular edema. At 6-week follow-up, OCT demonstrated patchy areas of atrophic inner nuclear layer and spontaneous resolution of the cystoid macular edema. Optical coherence tomography angiography at the level of the deep capillary plexus illustrated remarkable flow reduction of the deep capillary plexus in mainly a perivenular distribution. The authors report a case of a central retinal vein occlusion with mild retinal findings associated with a remarkable perivenular pattern of paracentral acute middle maculopathy with en face OCT. Follow-up OCT angiography demonstrated significant flow reduction of the deep capillary plexus in a perivenular pattern. The perivenular pattern of paracentral acute middle maculopathy lesions with en face OCT can be an important finding suggestive of a central retinal vein occlusion.

  4. Quantitative Spatial and Temporal Analysis of Fluorescein Angiography Dynamics in the Eye

    PubMed Central

    Hui, Flora; Nguyen, Christine T. O.; Bedggood, Phillip A.; He, Zheng; Fish, Rebecca L.; Gurrell, Rachel; Vingrys, Algis J.; Bui, Bang V.

    2014-01-01

    Purpose We describe a novel approach to analyze fluorescein angiography to investigate fluorescein flow dynamics in the rat posterior retina as well as identify abnormal areas following laser photocoagulation. Methods Experiments were undertaken in adult Long Evans rats. Using a rodent retinal camera, videos were acquired at 30 frames per second for 30 seconds following intravenous introduction of sodium fluorescein in a group of control animals (n = 14). Videos were image registered and analyzed using principle components analysis across all pixels in the field. This returns fluorescence intensity profiles from which, the half-rise (time to 50% brightness), half-fall (time for 50% decay) back to an offset (plateau level of fluorescence). We applied this analysis to video fluorescein angiography data collected 30 minutes following laser photocoagulation in a separate group of rats (n = 7). Results Pixel-by-pixel analysis of video angiography clearly delineates differences in the temporal profiles of arteries, veins and capillaries in the posterior retina. We find no difference in half-rise, half-fall or offset amongst the four quadrants (inferior, nasal, superior, temporal). We also found little difference with eccentricity. By expressing the parameters at each pixel as a function of the number of standard deviation from the average of the entire field, we could clearly identify the spatial extent of the laser injury. Conclusions This simple registration and analysis provides a way to monitor the size of vascular injury, to highlight areas of subtle vascular leakage and to quantify vascular dynamics not possible using current fluorescein angiography approaches. This can be applied in both laboratory and clinical settings for in vivo dynamic fluorescent imaging of vasculature. PMID:25365578

  5. Six-month outcome in unstable angina patients without previous myocardial infarction according to the use of tertiary cardiologic resources. RESCATE Investigators. Recursos Empleados en el Síndrome Coronario Agudo y Tiempos de Espera.

    PubMed

    Lupón, J; Valle, V; Marrugat, J; Elosua, R; Serés, L; Pavesi, M; Freixa, R; Sanz, G; Masiá, R; Molina, L; Sala, J; Serra, J

    1999-12-01

    The study assessed whether varying accessibility of patients with unstable angina (UA) to coronary angiography and revascularization determined differing usages and outcomes. The appropriate use rate of coronary angiography and revascularization procedures in UA remains to be established. A total of 791 consecutive patients with UA without previous acute myocardial infarction (AMI) admitted to four reference teaching hospitals (one with tertiary facilities) were followed for six months. End points were six-month mortality and readmission for AMI, UA, heart failure, or severe ventricular arrhythmias. Patients admitted to the tertiary hospital were 3.27 (95% confidence interval [CI] 2.32 to 4.62) times more likely to undergo coronary angiography after adjustment for comorbidity and severity than were those admitted to nontertiary facilities (overall six-month use rates 70.1% and 48.3%, respectively). Revascularization procedures were performed in 36.2% of patients in the tertiary hospital and 24.6% in the others (p = 0.0007); adjusted relative risk (RR) 2.37 (95% CI 1.55 to 3.63). Median delay for urgent coronary angiography was shorter in the tertiary hospital (24 h vs. 4 days, p < 0.0002). Six-month mortality and readmission rates were similar in tertiary and nontertiary hospitals: 3.9% versus 5.3% and 16.9% versus 21.2%, respectively. Adjusted RR of death or readmission for the nontertiary hospitals was 1.23 (95% CI 0.57 to 2.67). The use of coronary angiography and revascularization procedures in UA patients with no previous AMI is higher in tertiary than in nontertiary hospitals, but the more selective use of these procedures in nontertiary centers does not imply worse outcome.

  6. Cardiothoracic ratio within the “normal” range independently predicts mortality in patients undergoing coronary angiography

    PubMed Central

    Zaman, M Justin S; Sanders, Julie; Crook, Angela M; Feder, Gene; Shipley, Martin; Timmis, Adam; Hemingway, Harry

    2007-01-01

    Objective To determine whether cardiothoracic ratio (CTR), within the range conventionally considered normal, predicted prognosis in patients undergoing coronary angiography. Design Cohort study with a median of 7‐years follow‐up. Setting Consecutive patients undergoing coronary angiography at Barts and The London National Health Service (NHS) Trust. Subjects 1005 patients with CTRs measured by chest radiography, and who subsequently underwent coronary angiography. Of these patients, 7.3% had a CTR ⩾0.5 and were excluded from the analyses. Outcomes All‐cause mortality and coronary event (non‐fatal myocardial infarction or coronary death). Adjustments were made for age, left ventricular dysfunction, ACE inhibitor treatment, body mass index, number of diseased coronary vessels and past coronary artery bypass graft. Results The risk of death was increased among patients with a CTR in the upper part of the normal range. In total, 94 (18.9%) of those with a CTR below the median of 0.42 died compared with 120 (27.8%) of those with a CTR between 0.42 and 0.49 (log rank test p<0.001). After adjusting for potential confounders, this increased risk remained (adjusted HR 1.45, 95% CI 1.03 to 2.05). CTR, at values below 0.5, was linearly related to the risk of coronary event (test for trend p = 0.024). Conclusion : In patients undergoing coronary angiography, CTR between 0.42 and 0.49 was associated with higher mortality than in patients with smaller hearts. There was evidence of a continuous increase in risk with higher CTR. These findings, along with those in healthy populations, question the conventional textbook cut‐off point of ⩾0.5 being an abnormal CTR. PMID:17164481

  7. A Comparison of the Regional Circulation in the Feet between Dialysis and Non-Dialysis Patients using Indocyanine Green Angiography.

    PubMed

    Nishizawa, M; Igari, K; Kudo, T; Toyofuku, T; Inoue, Y; Uetake, H

    2017-09-01

    Peripheral artery disease in dialysis cases is more prone to critical limb ischemia compared to non-dialysis cases, with a significantly high rate of major amputation of the lower limbs. Lesions are distributed on the more distal side in dialysis critical limb ischemia cases. The aim of this study was to investigate the usefulness of indocyanine green angiography to determine differences in the regional circulation in the foot between dialysis and non-dialysis patients. The subjects included 62 cases, among which 20 were dialysis patients and 42 were non-dialysis patients. We compared the indocyanine green angiography parameters for regions of interest in the dialysis and non-dialysis groups, which included the magnitude of intensity from indocyanine green onset to maximum intensity (Imax), the time from indocyanine green onset to maximum intensity (Tmax), the time elapsed from the fluorescence onset to half the maximum intensity (T1/2), and the time from maximum intensity to declining to 90% of the maximum intensity (Td90%). These indocyanine green angiography parameters were measured at region of interest 1 (the Chopart joint), region of interest 2 (the Lisfranc joint), and region of interest 3 (the distal region of the first metatarsal bone). In the comparison between the dialysis and non-dialysis groups, a significant difference was observed regarding Tmax, T1/2, and Td90%, especially in region of interest 3. In this study, we show that regional tissue perfusion is more deteriorated in dialysis patients compared with non-dialysis patients using indocyanine green angiography. Tmax, T1/2, and Td90% could be useful clinical parameters to compare ischemic severity of the lower limb between dialysis and non-dialysis patients.

  8. Indocyanine green fluorescence angiography for free flap monitoring: A pilot study.

    PubMed

    Hitier, Marine; Cracowski, Jean-Luc; Hamou, Cynthia; Righini, Christian; Bettega, Georges

    2016-11-01

    We evaluated the feasibility and the tolerance of repeated fluorescent indocyanine green angiography in free flap monitoring, and determined the intraoperative predictive values of flap vitality. The free flap failure rate has been significantly reduced, but free flap loss still occurs and remains a costly disaster. Repeated clinical examinations are commonly used for flap monitoring, but they can be unreliable because of their subjectivity. Laser-induced fluorescence of indocyanine green is a new method for assessing tissue perfusion. 20 patients undergoing microsurgical reconstruction were monitored by indocyanine green fluorescence angiography, intraoperatively, and during 4 days after surgery, with 18 injections. Monitoring was made by clinical examination, and then compared to angiographic findings. The vascular complication rate was 15% (3/20) with 2 cases of venous thrombosis and one case of partial necrosis of the flap skin paddle. Both cases of venous thrombosis were salvaged by secondary surgery. There was no total flap loss. ICG angiography allowed detecting each intra and postoperative complication, earlier than clinical examination. The mean per-operative intensity of fluorescence was significantly lower in flaps with vascular complications (23.8 GL/ms; p = 0.008). The postoperative slope (p = 0.02) and amplitude (p = 0.03) of the fluorescent signal were both significantly lower than for uncomplicated flaps, before surgical revision. These 2 parameters came back to normal values after secondary surgery. There was no adverse effect of ICG despite the repeated injections. ICG angiography is a feasible and safe technique for the detection of free flap vascular complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

    PubMed

    Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M

    2015-03-01

    Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.

  10. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images.

    PubMed

    Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige

    2010-10-01

    The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4±1.1mm, which was statistically smaller than that of 13 control patients, 6.0±1.5mm (P<0.05, Wilcoxon rank sum tests). Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  11. Software-based on-site estimation of fractional flow reserve using standard coronary CT angiography data.

    PubMed

    De Geer, Jakob; Sandstedt, Mårten; Björkholm, Anders; Alfredsson, Joakim; Janzon, Magnus; Engvall, Jan; Persson, Anders

    2016-10-01

    The significance of a coronary stenosis can be determined by measuring the fractional flow reserve (FFR) during invasive coronary angiography. Recently, methods have been developed which claim to be able to estimate FFR using image data from standard coronary computed tomography angiography (CCTA) exams. To evaluate the accuracy of non-invasively computed fractional flow reserve (cFFR) from CCTA. A total of 23 vessels in 21 patients who had undergone both CCTA and invasive angiography with FFR measurement were evaluated using a cFFR software prototype. The cFFR results were compared to the invasively obtained FFR values. Correlation was calculated using Spearman's rank correlation, and agreement using intraclass correlation coefficient (ICC). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for significant stenosis (defined as both FFR ≤0.80 and FFR ≤0.75) were calculated. The mean cFFR value for the whole group was 0.81 and the corresponding mean invFFR value was 0.84. The cFFR sensitivity for significant stenosis (FFR ≤0.80/0.75) on a per-lesion basis was 0.83/0.80, specificity was 0.76/0.89, and accuracy 0.78/0.87. The positive predictive value was 0.56/0.67 and the negative predictive value was 0.93/0.94. The Spearman rank correlation coefficient was ρ = 0.77 (P < 0.001) and ICC = 0.73 (P < 0.001). This particular CCTA-based cFFR software prototype allows for a rapid, non-invasive on-site evaluation of cFFR. The results are encouraging and cFFR may in the future be of help in the triage to invasive coronary angiography. © The Foundation Acta Radiologica 2015.

  12. Changes in peripapillary blood vessel density in Graves' orbitopathy after orbital decompression surgery as measured by optical coherence tomography angiography.

    PubMed

    Lewis, Kyle T; Bullock, John R; Drumright, Ryan T; Olsen, Matthew J; Penman, Alan D

    2018-03-08

    The purpose is to evaluate the utility of optical coherence tomography (OCT) angiography in the evaluation of Graves' orbitopathy (GO) and response to orbital decompression in patients with and without dysthyroid optic neuropathy (DON). This was a single-center, prospective case series in a cohort of 12 patients (24 orbits) with GO and ±DON, (6 orbits) who underwent bilateral orbital decompression. All patients underwent pre- and postoperative OCT angiography of the peripapillary area. Vessel density indices were calculated in a 4.5 mm × 4.5 mm ellipsoid centered on the optic disk using split-spectrum amplitude decorrelation angiography algorithm, producing the vessel density measurements. Mean change in vessel density indices was compared between pre- and postoperative sessions and between patients with and without DON. Patient 1, a 34-year-old male with GO and unilateral DON OD, showed a significant reduction in blood vessel density indices oculus dexter (OD) (DON eye) after decompression while a more modest reduction was found oculus sinister (OS) with the greatest change noted intrapapillary. Patient 2, a 50-year-old male with DON OU, showed worsening neuropathy following decompression OD that was confirmed by angiographic density indices. Patient 3, a 55-year-female with DON, showed a reduction in blood vessel density OD and increased density OS. Patients without DON showed overall less impressive changes in indices as compared to those with DON. Using OCT angiography, response to surgical treatment in GO orbits, more so in orbits with DON, can be demonstrated and quantified using vessel density indices with reproducibility.

  13. Utility of 16-MDCT angiography for comprehensive preoperative vascular evaluation of laparoscopic renal donors.

    PubMed

    Raman, Steven S; Pojchamarnwiputh, Suwalee; Muangsomboon, Kobkun; Schulam, Peter G; Gritsch, H Albin; Lu, David S K

    2006-06-01

    Our objective was to determine the efficacy of 16-MDCT angiography in preoperative evaluation of vascular anatomy of laparoscopic renal donors. Fifty-five consecutive renal donors (25 men and 30 women) underwent 16-MDCT angiography followed by donor nephrectomy. In the arterial and nephrographic phases, images were acquired with 60% overlap and 0.6-mm reconstruction in both phases after 120 mL of iohexol was injected at 4 mL/sec. On a 3D workstation, images were evaluated retrospectively by two abdominal imagers blinded to surgical results with respect to number and branching pattern of renal arteries and major and minor renal veins. These CT angiography results were compared with surgical findings. The surgically confirmed sensitivity of both reviewers (1 and 2) using the MDCT data for detection of renal arteries was 98.5% (65 of 66), and accuracies were 97.0% for reviewer 1 and 95.5% for reviewer 2. Sensitivity and accuracy detection of renal veins was 97% (61 of 63) and 98% (62 of 63) for reviewer 1 and reviewer 2, respectively. Sensitivity and accuracy detection of early arterial bifurcation (< 2 cm from aorta) was 100% (14 of 14), and sensitivity in detection of late venous confluence (< 1.5 cm from aorta) was 100% (8 of 8). All major renal venous variants were identified; reviewer 1 identified 78% (18 of 23) minor venous variants, and reviewer 2 identified 83% (19 of 23) minor venous variants. There were no hemorrhagic complications at surgery. Excellent agreement between reviewers (kappa = 0.92-0.97) was achieved for detection of normal and variant anatomy. 16-MDCT angiography enabled excellent preoperative detection of arterial anatomy and venous laparoscopic donor nephrectomy.

  14. Evaluation of Collaterals and Clot Burden Using Time-Resolved C-Arm Conebeam CT Angiography in the Angiography Suite: A Feasibility Study.

    PubMed

    Yang, P; Niu, K; Wu, Y; Struffert, T; Doerfler, A; Holter, P; Aagaard-Kienitz, B; Strother, C; Chen, G-H

    2017-04-01

    The assessment of collaterals and clot burden in patients with acute ischemic stroke provides important information about treatment options and clinical outcome. Time-resolved C-arm conebeam CT angiography has the potential to provide accurate and reliable evaluations of collaterals and clot burden in the angiographic suite. Experience with this technique is extremely limited, and feasibility studies are needed to validate this technique. Our purpose was to present such a feasibility study. Ten C-arm conebeam CT perfusion datasets from 10 subjects with acute ischemic stroke acquired before endovascular treatment were retrospectively processed to generate time-resolved conebeam CTA. From time-resolved conebeam CTA, 2 experienced readers evaluated the clot burden and collateral flow in consensus by using previously reported scoring systems and assessed the clinical value of this novel imaging technique independently. Interobserver agreement was analyzed by using the intraclass correlation analysis method. Clot burden and collateral flow can be assessed by using the commonly accepted scoring systems for all eligible cases. Additional clinical information (eg, the quantitative dynamic information of collateral flow) can be obtained from this new imaging technique. Two readers agreed that time-revolved C-arm conebeam CTA is the preferred method for evaluating the clot burden and collateral flow compared with other conventional imaging methods. Comprehensive evaluations of clot burden and collateral flow are feasible by using time-resolved C-arm conebeam CTA data acquired in the angiography suite. This technique further enriches the imaging tools in the angiography suite to enable a "one-stop- shop" imaging workflow for patients with acute ischemic stroke. © 2017 by American Journal of Neuroradiology.

  15. Do Physicians Do What They Say?

    PubMed Central

    Wennberg, David E; Dickens, John D; Biener, Lois; Fowler, Floyd J; Soule, David N; Keller, Robert B

    1997-01-01

    OBJECTIVE Efforts to evaluate variations in cardiac procedures have focused on patient factors and differences in health care delivery systems. We wanted to assess how physicians’ inclination to test patients with coronary artery disease influences utilization patterns. SETTING AND SUBJECTS Physicians and the populations of Maine, New Hampshire, and Vermont. DESIGN We conducted a survey of 263 family practitioners, internists, and cardiologists residing in 57 hospital service areas in Maine, New Hampshire, and Vermont. Using patient scenarios, we assessed the clinicians’ inclinations to test during the evaluation of patients with coronary artery disease. Self-reported testing intensities were used to create three indices: a Catheterization Index, an Imaging Exercise Tolerance Test (ETT) Index, and a Nonimaging ETT Index. Using administrative data, age- and gender-adjusted population-based coronary angiography rates were calculated. Physicians were assigned to low (2.9/1,000), average (4.2/1,000), and high (5.8/1,000) coronary angiography rate areas, based on where they practice. Analysis of variance techniques were used to assess the relation of the index scores to the population-based coronary angiography rates and to physician specialties. RESULTS There was a positive relationship between the population-based coronary angiography rates and the self-reported scores of the Catheterization Index (p < .005) and the Imaging ETT Index (p = .01), but none was found for the Nonimaging ETT Index (p = .10). These relationships were evident in subanalyses of cardiologists and internists, but not of family practitioners. CONCLUSIONS Self-reported testing intensity by physicians is related to the population-based rates of coronary angiography. This relationship cuts across specialties, suggesting that there is a “medical signature” for the evaluation of patients with coronary artery disease.

  16. Relationship between pseudoaneurysm formation and biloma after successful transarterial embolization for severe hepatic injury: permanent embolization using stainless steel coils prevents pseudoaneurysm formation.

    PubMed

    Hagiwara, Akiyoshi; Tarui, Takehiko; Murata, Atsuo; Matsuda, Takeaki; Yamaguti, Yoshihiro; Shimazaki, Shuji

    2005-07-01

    The purpose of this study was to determine the association between bilomas and pseudoaneurysm complications after severe hepatic injury. Angiography was performed in patients with American Association for the Surgery of Trauma grade > or = III hepatic injury on contrast-enhanced computed tomographic scanning. When contrast extravasation was observed, transarterial embolization (TAE) was performed. After TAE, technetium-99m pyridoxyl-5-methyl-tryptophan cholescintigraphy was performed to detect the coexistence of bilomas. Follow-up angiography was performed when a biloma was detected. Eighty consecutive patients underwent angiography; after angiography, five patients died. The remaining 75 patients who underwent cholescintigraphy were included in this study. All 11 patients who had bilomas had angiographic evidence of contrast extravasation. The biloma frequency was higher in patients with grades IV and V injuries than in those with grade III injury (p = 0.024). Follow-up angiography revealed pseudoaneurysms in 7 of these 11 patients. All six patients in whom only gelatin sponge pledget injection was used to embolize had pseudoaneurysms. Among them, two patients had computed tomographic evidence of massive intra-abdominal fluid collection. In contrast, only one of five patients who received the combination of gelatin sponge pledget injection and stainless steel coils to permanently embolize injured arteries had a pseudoaneurysm. In this patient, the pseudoaneurysm was found in the peripheral part of the collateral vessels. All patients with pseudoaneurysms underwent repeat TAE and were discharged from the hospital uneventfully. In patients with high-grade hepatic injury and arterial bleeding who developed biloma, use of a gelatin sponge, an absorbable embolic material, is associated with a risk of pseudoaneurysm formation. Permanent arterial embolization using stainless steel coils is indicated to decrease this risk.

  17. Latest-generation catheterization systems enable invasive submillisievert coronary angiography.

    PubMed

    Kuon, E; Weitmann, K; Hummel, A; Dörr, M; Reffelmann, T; Riad, A; Busch, M C; Felix, S B; Hoffmann, W; Empen, K

    2015-05-01

    The radiation risk of patients undergoing invasive cardiology remains considerable and includes skin injuries and cancer. To date, submillisievert coronary angiography has not been considered feasible. In 2011, we compared results from 100 consecutive patients undergoing elective coronary angiography using the latest-generation flat-panel angiography system (FPS) with results from examinations by the same operator using 106 historic controls with a conventional image-intensifier system (IIS) that was new in 2002. The median patient exposure parameters were measured as follows: dose-area product (DAP) associated with radiographic cine acquisitions (DAP(R)) and fluoroscopy (DAP(F)) scenes, radiographic frames and runs, and cumulative exposure times for radiography and fluoroscopy. On the FPS as compared to the traditional IIS, radiographic detector entrance dose levels were reduced from 164 to 80 nGy/frame and pulse rates were lowered from 12.5/s to 7.5/s during radiography and from 25/s to 4/s during fluoroscopy. The cardiologist's performance patterns remained comparable over the years: fluoroscopy time was constant and radiography time even slightly increased. Overall patient DAP decreased from 7.0 to 2.4 Gy × cm(2); DAP(R), from 4.2 to 1.7 Gy × cm(2); and DAP(F), from 2.8 to 0.6 Gy × cm(2). Time-adjusted DAP(R)/s decreased from 436 to 130 mGy × cm(2) and DAP(F)/s, from 21.6 to 4.4 mGy × cm(2). Cumulative patient skin dose with the FPS amounted to 67 mGy, and the median (interquartile range) of effective dose was 0.5 (0.3 … 0.7) mSv. Consistent application of radiation-reducing techniques with the latest-generation flat-panel systems enables submillisievert coronary angiography in invasive cardiology.

  18. Diagnostic Accuracy of Computer Tomography Angiography and Magnetic Resonance Angiography in the Stenosis Detection of Autologuous Hemodialysis Access: A Meta-Analysis

    PubMed Central

    Liu, Shiyuan

    2013-01-01

    Purpose To compare the diagnostic performances of computer tomography angiography (CTA) and magnetic resonance angiography (MRA) for detection and assessment of stenosis in patients with autologuous hemodialysis access. Materials and Methods Search of PubMed, MEDLINE, EMBASE and Cochrane Library database from January 1984 to May 2013 for studies comparing CTA or MRA with DSA or surgery for autologuous hemodialysis access. Eligible studies were in English language, aimed to detect more than 50% stenosis or occlusion of autologuous vascular access in hemodialysis patients with CTA and MRA technology and provided sufficient data about diagnosis performance. Methodological quality was assessed by the Quality Assessment of Diagnostic Studies (QUADAS) instrument. Sensitivities (SEN), specificities (SPE), positive likelihood ratio (PLR), negative likelihood values (NLR), diagnostic odds ratio (DOR) and areas under the receiver operator characteristic curve (AUC) were pooled statistically. Potential threshold effect, heterogeneity and publication bias was evaluated. The clinical utility of CTA and MRA in detection of stenosis was also investigated. Result Sixteen eligible studies were included, with a total of 500 patients. Both CTA and MRA were accurate modality (sensitivity, 96.2% and 95.4%, respectively; specificity, 97.1 and 96.1%, respectively; DOR [diagnostic odds ratio], 393.69 and 211.47, respectively) for hemodialysis vascular access. No significant difference was detected between the diagnostic performance of CTA (AUC, 0.988) and MRA (AUC, 0.982). Meta-regression analyses and subgroup analyses revealed no statistical difference. The Deek’s funnel plots suggested a publication bias. Conclusion Diagnostic performance of CTA and MRA for detecting stenosis of hemodialysis vascular access had no statistical difference. Both techniques may function as an alternative or an important complement to conventional digital subtraction angiography (DSA) and may be able to help guide medical management. PMID:24194928

  19. En face optical coherence tomography angiography for corneal neovascularisation.

    PubMed

    Ang, Marcus; Cai, Yijun; Shahipasand, Shahab; Sim, Dawn A; Keane, Pearse A; Sng, Chelvin C A; Egan, Catherine A; Tufail, Adnan; Wilkins, Mark R

    2016-05-01

    Recently, there has been an increasing clinical need for objective evaluation of corneal neovascularisation, a condition which cause significant ocular morbidity. We describe the use of a rapid, non-invasive 'en face' optical coherence tomography angiography (OCTA) system for the assessment of corneal neovascularisation. Consecutive patients with abnormal corneal neovascularisation were scanned using a commercially available AngioVue OCTA system (Optovue, Fremont, California, USA) with the split-spectrum amplitude decorrelation angiography algorithm, using an anterior segment lens adapter. Each subject had four scans in each eye by a trained operator and two independent masked assessors analysed all images. Main outcome measures were scan quality (signal strength, image quality), area of neovascularisation and repeatability of corneal vascular grade. We performed OCTA in 20 patients (11 men, 9 women, mean age 49.27±17.23 years) with abnormal corneal neovascularisation. The mean area of corneal neovascularisation was 0.57±0.30 mm(2) with a mean neovascularisation grade of 3.5±0.2 in the OCTA scans. We found the OCTA to produce good quality images of the corneal vessels (signal strength: 36.95±13.97; image quality score 2.72±1.07) with good repeatability for assessing neovascularisation grade (κ=0.84). In this preliminary clinical study, we describe a method for acquiring angiography images with 'en face' views, using an OCTA system adapted for the evaluation of corneal neovascularisation. Further studies are required to compare the scans to other invasive angiography techniques for the quantitative evaluation of abnormal corneal vessels. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Feasibility of MDCT angiography for determination of tumor-feeding vessels in chemoembolization of hepatocellular carcinoma.

    PubMed

    Kim, Inwha; Kim, Dae Jung; Kim, Kyoung Ah; Yoon, Sang Wook; Lee, Jong Tae

    2014-01-01

    To investigate the feasibility and accuracy of multidetector computed tomography (MDCT) angiography for assessment of subsegmental tumor-feeding vessels in transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). A total of 23 patients with 36 HCCs who underwent TACE during a 14-month period were enrolled. All patients underwent 3-phase dynamic MDCT within a month before TACE. Arterial phase MDCT images were retrospectively reformatted and analyzed for determination of single subsegmental tumor-feeding vessel using maximum intensity projection (MIP) and volume-rendering technique (VRT). Two radiologists independently assessed and scored the MIP and VRT images using 4-grade visual scores (grade 1, no depiction of tumor-feeding vessel; grade 2, indeterminate tumor-feeding vessel; grade 3, probable tumor-feeding vessel; and grade 4, good depiction of tumor-feeding vessel). The weighted kappa test was used to determine interobserver variability, and Wilcoxon signed rank test was used to differentiate visual scores of each technique. Results of digital subtraction angiography were defined as the criterion standard; therefore, assessment of subsegmental tumor-feeding vessel using MIP or VRT was compared with digital subtraction angiography, and the accuracy of each technique was calculated. Interobserver agreement (weighted kappa, 0.746 on VRT and 0.806 on MIP) was substantial to almost perfect. The visual scores for MIP (mean, 3.64 for reviewer 1 and 3.5 for reviewer 2) were higher than those for VRT (mean, 2.11 for reviewer 1 and 2.22 for reviewer 2; P = 0.000). The accuracy for assessing subsegmental tumor-feeding vessel was 22.2% for VRT and 77.8% for MIP. Multidetector CT angiography using MIP showed good imaging quality and high accuracy for determination of subsegmental tumor-feeding vessels.

  1. Effective doses in children: association with common complex imaging techniques used during interventional radiology procedures.

    PubMed

    Lai, Priscilla; McNeil, Sarah M; Gordon, Christopher L; Connolly, Bairbre L

    2014-12-01

    The purpose of this study was to determine the range of effective doses associated with imaging techniques used during interventional radiology procedures on children. A pediatric phantom set (1, 5, and 10 years) coupled with high-sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeters was used to calculate effective doses. Twenty MOSFETs were inserted into each phantom at radiosensitive organ locations. The phantoms were exposed to mock head, chest, and abdominal interventional radiology procedures performed with different geometries and magnifications. Fluoroscopy, digital subtraction angiography (DSA), and spin angiography were simulated on each phantom. Road mapping was conducted only on the 5-year-old phantom. International Commission on Radiological Protection publication 103 tissue weights were applied to the organ doses recorded with the MOSFETs to determine effective dose. For easy application to clinical cases, doses were normalized per minute of fluoroscopy and per 10 frames of DSA or spin angiography. Effective doses from DSA, angiography, and fluoroscopy were higher for younger ages because of magnification use and were largest for abdominal procedures. DSA of the head, chest, and abdomen (normalized per 10 frames) imparted doses 2-3 times as high as corresponding doses per minute of fluoroscopy while all other factors remained unchanged (age, projection, collimation, magnification). Three to five frames of DSA imparted an effective dose equal to doses from 1 minute of fluoroscopy. Doses from spin angiography were almost one-half the doses received from an equivalent number of frames of DSA. Patient effective doses during interventional procedures vary substantially depending on procedure type but tend to be higher because of magnification use in younger children and higher in the abdomen.

  2. Non-enhanced, ECG-gated MR angiography of the pedal vasculature: comparison with contrast-enhanced MR angiography and digital subtraction angiography in peripheral arterial occlusive disease.

    PubMed

    Schubert, Tilman; Takes, Martin; Aschwanden, Markus; Klarhoefer, Markus; Haas, Tanja; Jacob, Augustinus L; Liu, David; Gutzeit, Andreas; Kos, Sebastian

    2016-08-01

    This study was conducted in order to compare a high resolution, non-contrast-enhanced MRA (NATIVE SPACE, NE-MRA) of the pedal vasculature with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease (PAOD). The prospective study consists of 20 PAOD patients. All patients underwent percutaneous transluminal angioplasty or stenting and received MR angiographies the following day. With CE-MRA, 75.7 % of vessel segments showed good, 16.4 % suboptimal and 7.9 % not usable image quality. With NE-MRA, 64.6 % showed good, 18.6 % suboptimal and 16.8 % not usable image quality. CE-MRA showed a sensitivity and negative predictive value of 90 %/95 % regarding significant stenosis (greater than 50 %), and specificity and positive predictive value were 88 %/77 %. Accordingly, sensitivity and negative predictive value for the NE-MRA were 96 %/97 % and specificity and positive predictive value were 80 %/69 % for stenoses greater than 50 %. The applied NE-MRA technique achieves high diagnostic accuracy even in very small distal arteries of the foot. However, the rate of non-diagnostic vessel segments is considerably higher for NE-MRA than for CE-MRA. NE-MRA is a valuable alternative to CE-MRA in selected patients. • Comparison of non-enhanced MRA with contrast-enhanced MRA and DSA as gold standard. • High resolution MRA at 3 T for the depiction of small pedal vessels. • Evaluation of high resolution non-enhanced MRA in PAOD patients.

  3. ST-segment resolution with bivalirudin versus heparin and routine glycoprotein IIb/IIIa inhibitors started in the ambulance in ST-segment elevation myocardial infarction patients transported for primary percutaneous coronary intervention: The EUROMAX ST-segment resolution substudy.

    PubMed

    Van't Hof, Arnoud; Giannini, Francesco; Ten Berg, Jurrien; Tolsma, Rudolf; Clemmensen, Peter; Bernstein, Debra; Coste, Pierre; Goldstein, Patrick; Zeymer, Uwe; Hamm, Christian; Deliargyris, Efthymios; Steg, Philippe G

    2017-08-01

    Myocardial reperfusion after primary percutaneous coronary intervention (PCI) can be assessed by the extent of post-procedural ST-segment resolution. The European Ambulance Acute Coronary Syndrome Angiography (EUROMAX) trial compared pre-hospital bivalirudin and pre-hospital heparin or enoxaparin with or without GPIIb/IIIa inhibitors (GPIs) in primary PCI. This nested substudy was performed in centres routinely using pre-hospital GPI in order to compare the impact of randomized treatments on ST-resolution after primary PCI. Residual cumulative ST-segment deviation on the single one hour post-procedure electrocardiogram (ECG) was assessed by an independent core laboratory and was the primary endpoint. It was calculated that 762 evaluable patients were needed to show non-inferiority (85% power, alpha 2.5%) between randomized treatments. A total of 871 participated with electrocardiographic data available in 824 patients (95%). Residual ST-segment deviation one hour after PCI was 3.8±4.9 mm versus 3.9±5.2 mm for bivalirudin and heparin+GPI, respectively ( p=0.0019 for non-inferiority). Overall, there were no differences between randomized treatments in any measures of ST-segment resolution either before or after the index procedure. Pre-hospital treatment with bivalirudin is non-inferior to pre-hospital heparin + GPI with regard to residual ST-segment deviation or ST-segment resolution, reflecting comparable myocardial reperfusion with the two strategies.

  4. Reducing angiographic cystoid macular edema and blood-aqueous barrier disruption after small-incision phacoemulsification and foldable intraocular lens implantation: multicenter prospective randomized comparison of topical diclofenac 0.1% and betamethasone 0.1%.

    PubMed

    Asano, Sayaka; Miyake, Kensaku; Ota, Ichiro; Sugita, Gentaro; Kimura, Wataru; Sakka, Yuji; Yabe, Nobuyuki

    2008-01-01

    To compare the effectiveness of a topical nonsteroidal drug (diclofenac 0.1%) and a topical steroidal drug (betamethasone 0.1%) in preventing cystoid macular edema (CME) and blood-aqueous barrier (BAB) disruption after small-incision cataract surgery and foldable intraocular lens (IOL) implantation. Shohzankai Medical Foundation Miyake Eye Hospital, Tokyo, Japan. This multicenter interventional double-masked randomized study comprised 142 patients having phacoemulsification and foldable IOL implantation. Seventy-one patients were randomized to receive diclofenac eyedrops and 71, betamethasone eyedrops for 8 weeks postoperatively. The incidence and severity of CME were evaluated by fluorescein angiography. Blood-aqueous barrier disruption was determined by laser flare-cell photometry. Of the patients, 63 were men and 79 were women. Five weeks after surgery, the incidence of fluorescein angiographic CME was lower in the diclofenac group (18.8%) than in the betamethasone group (58.0%) (P<.001). At 1 and 2 weeks, the amount of anterior chamber flare was statistically significantly less in the diclofenac group than in the betamethasone group (P<.05). At 8 weeks, intraocular pressure was statistically significantly higher in the betamethasone group (P = .0003). Diclofenac was more effective than betamethasone in preventing angiographic CME and BAB disruption after small-incision cataract surgery. Thus, nonsteroidal antiinflammatory agents should be considered for routine treatment of eyes having cataract surgery.

  5. The Effect of a Vegan versus AHA DiEt in Coronary Artery Disease (EVADE CAD) trial: study design and rationale.

    PubMed

    Shah, Binita; Ganguzza, Lisa; Slater, James; Newman, Jonathan D; Allen, Nicole; Fisher, Edward; Larigakis, John; Ujueta, Francisco; Gianos, Eugenia; Guo, Yu; Woolf, Kathleen

    2017-12-01

    Multiple studies demonstrate the benefit of a vegan diet on cardiovascular risk factors when compared to no intervention or usual dietary patterns. The aim of this study is to evaluate the effect of a vegan diet versus the American Heart Association (AHA)-recommended diet on inflammatory and glucometabolic profiles in patients with angiographically defined coronary artery disease (CAD). This study is a randomized, open label, blinded end-point trial of 100 patients with CAD as defined by ≥50% diameter stenosis in a coronary artery ≥2 mm in diameter on invasive angiography. Participants are randomized to 8 weeks of either a vegan or AHA-recommended diet (March 2014 and February 2017). Participants are provided weekly groceries that adhere to the guidelines of their diet. The primary endpoint is high sensitivity C-reactive concentrations. Secondary endpoints include anthropometric data, other markers of inflammation, lipid parameters, glycemic markers, endothelial function, quality of life data, and assessment of physical activity. Endpoints are measured at each visit (baseline, 4 weeks, and 8 weeks). Dietary adherence is measured by two weekly 24-hour dietary recalls, a 4-day food record during the week prior to each visit, and both plasma and urine levels of trimethylamine- N -oxide at each visit. This study is the first to comprehensively assess multiple indices of inflammation and glucometabolic profile in a rigorously conducted randomized trial of patients with CAD on a vegan versus AHA-recommended diet.

  6. Optical Coherence Tomography Angiography of Retinal Cavernous Hemangioma.

    PubMed

    Pierro, Luisa; Marchese, Alessandro; Gagliardi, Marco; Bandello, Francesco

    2017-08-01

    Retinal cavernous hemangioma is a rare, benign, retinal tumor characterized by angiomatous proliferation of vessels within the inner retina or the optic disc.1 Here we report a case of retinal cavernous hemangioma on the margin of the optic disc in the right eye of a 61-year-old asymptomatic female. The lesion was studied with multimodal imaging which included structural optical coherence tomography, fluorescein angiography, blue fundus auto-fluorescence, optical coherence tomography angiography (OCTA) (DRI OCT Triton; Topcon, Tokyo, Japan) and visual field examination. Blood circulation inside retinal cavernous hemangioma lesion is typically low-stagnant.2 However, OCTA demonstrated blood flow inside the lesion, illustrating its vascular circulation.3 Visual field was within the normal limits, except from a slight enlargement of the blind spot. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:684-685.]. Copyright 2017, SLACK Incorporated.

  7. [Indocyanine green angiography in "multiple evanescent white dot syndrome" (MEWDS)].

    PubMed

    Desarnaulds, A B; Borruat, F X; Herbort, C P; de Courten, C

    1998-05-01

    Multiple evanescent white dot syndrome (MEWDS) is a benign acquired chorioretinal disorder occurring mostly in young adults. Its pathophysiology is unknown. To describe the results of indocyanine green angiography (ICGA) in MEWDS. Four patients with MEWDS were investigated by ICGA. In all cases, ICGA revealed numerous choroidal hypofluorescent lesions that largely outnumbered the lesions visible with either fundoscopy or fluorescein angiography. Three cases showed a blind spot enlargement on perimetry associated with the presence of a large peripapillary hypofluorescent zone on ICGA. Three cases showed macular granularity on fundoscopy correlating with a significant subfoveal hypfluorescent lesion on ICGA. Evolution was always favorable with disappearance of the hypofluorescent choroidal lesions. Our results confirm that MEWDS is primarily a choroidal disorder. The blind spot enlargement and the macular granularity, frequently detected in MEWDS, result from larger peripapillary and subfoveal choroidal lesions.

  8. Reversible cerebral vasoconstriction syndrome with involvement of external carotid artery branches.

    PubMed

    Shaik, S; Chhetri, S K; Roberts, G; Wuppalapati, S; Emsley, H C A

    2014-07-01

    A 44-year-old woman presented with recurrent episodes of thunderclap headache. Neurological examination and computed tomography brain imaging were unremarkable. Cerebrospinal fluid findings were consistent with subarachnoid hemorrhage. Computed tomography angiography of the circle of Willis showed multiple areas of segmental vasoconstriction. This finding was confirmed on cerebral catheter angiography, with segmental vasoconstriction involving bilateral internal carotid, posterior cerebral, and external carotid branches. No aneurysm or other vascular abnormality was identified. She received treatment with nimodipine. A selective serotonin reuptake inhibitor, started 4 weeks earlier, was discontinued. Follow-up angiography after 3 months demonstrated complete resolution of the segmental vasoconstriction, confirming the diagnosis of reversible cerebral vasoconstriction syndrome (RCVS). She remained headache free at follow-up. To our knowledge, external carotid artery branch involvement in RCVS has been described only in one previous occasion.

  9. Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know

    PubMed Central

    Saade, Charbel; Deeb, Ibrahim Alsheikh; Mohamad, Maha; Al-Mohiy, Hussain; El-Merhi, Fadi

    2016-01-01

    Over the last decade, exponential advances in computed tomography (CT) technology have resulted in improved spatial and temporal resolution. Faster image acquisition enabled renal CT angiography to become a viable and effective noninvasive alternative in diagnosing renal vascular pathologies. However, with these advances, new challenges in contrast media administration have emerged. Poor synchronization between scanner and contrast media administration have reduced the consistency in image quality with poor spatial and contrast resolution. Comprehensive understanding of contrast media dynamics is essential in the design and implementation of contrast administration and image acquisition protocols. This review includes an overview of the parameters affecting renal artery opacification and current protocol strategies to achieve optimal image quality during renal CT angiography with iodinated contrast media, with current safety issues highlighted. PMID:26728701

  10. OCT Angiography Helps Distinguish Between Proliferative Macular Telangiectasia Type 2 and Neovascular Age-Related Macular Degeneration.

    PubMed

    Zheng, Fang; Motulsky, Elie H; de Oliveira Dias, João Rafael; de López, Edith Pérez; Gregori, Giovanni; Rosenfeld, Philip J

    2018-05-01

    To demonstrate the advantage of optical coherence tomography angiography (OCTA) for the diagnosis and management of proliferative macular telangiectasia type 2 (MacTel2) masquerading as neovascular age-related macular degeneration (AMD). This is an observational cases series. Three patients referred with the diagnosis of neovascular AMD were identified in this retrospective study. In addition to color fundus, fluorescein angiography, and spectral-domain OCT (SD-OCT) imaging, SD-OCTA (AngioPlex; Carl Zeiss Meditec, Dublin, CA) was performed. SD-OCTA revealed bilateral parafoveal retinal microvascular changes in three patients and unambiguously confirmed the diagnosis of MacTel2. OCTA is an important tool for the correct diagnosis of MacTel2 in older patients with the concomitant or masquerading diagnosis of AMD. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:303-312.]. Copyright 2018, SLACK Incorporated.

  11. Ultrahigh-speed non-invasive widefield angiography

    NASA Astrophysics Data System (ADS)

    Blatter, Cedric; Klein, Thomas; Grajciar, Branislav; Schmoll, Tilman; Wieser, Wolfgang; Andre, Raphael; Huber, Robert; Leitgeb, Rainer A.

    2012-07-01

    Retinal and choroidal vascular imaging is an important diagnostic benefit for ocular diseases such as age-related macular degeneration. The current gold standard for vessel visualization is fluorescence angiography. We present a potential non-invasive alternative to image blood vessels based on functional Fourier domain optical coherence tomography (OCT). For OCT to compete with the field of view and resolution of angiography while maintaining motion artifacts to a minimum, ultrahigh-speed imaging has to be introduced. We employ Fourier domain mode locking swept source technology that offers high quality imaging at an A-scan rate of up to 1.68 MHz. We present retinal angiogram over ˜48 deg acquired in a few seconds in a single recording without the need of image stitching. OCT at 1060 nm allows for high penetration in the choroid and efficient separate characterization of the retinal and choroidal vascularization.

  12. Dengue eye disease.

    PubMed

    Ng, Aaron W; Teoh, Stephen C

    2015-01-01

    Dengue fever, a viral disease epidemic in some parts of the world, is of considerable international concern, with a growing incidence owing to developing urbanization, tourism, and trade. Ocular manifestations of dengue fever are uncommon, but of great significance. Proposed mechanisms include direct viral infection as well as immunologic phenomena. Common manifestations include subconjunctival, vitreous, and retinal hemorrhages; posterior uveitis; optic neuritis; and maculopathies such as foveolitis, hemorrhage, and edema. Main symptoms include blurring of vision, scotomata, metamorphopsia, and floaters. Diagnostic and monitoring investigations described included optical coherence tomography, fundus fluorescein and indocyanine green angiography, visual field analysis, and electrophysiologic tests. Management is based on clinical presentation and includes active surveillance as well as various anti-inflammatory and immunosuppressive therapies. There have been no prospective, randomized therapeutic trials, and it is unclear if the disease is self-limiting or if treatment is actually beneficial. Prognosis varies, ranging from full resolution to permanent vision loss despite intervention. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. 3.0Tesla magnetic resonance angiography (MRA) for comprehensive renal evaluation of living renal donors: pilot study with computerized tomography angiography (CTA) comparison.

    PubMed

    Gulati, Mittul; Dermendjian, Harout; Gómez, Ana M; Tan, Nelly; Margolis, Daniel J; Lu, David S; Gritsch, H Albin; Raman, Steven S

    2016-01-01

    Most living related donor (LRD) kidneys are harvested laparoscopically. Renal vascular anatomy helps determine donor suitability for laparoscopic nephrectomy. Computed tomography angiography (CTA) is the current gold standard for preoperative imaging; magnetic resonance angiography (MRA) offers advantages including lack of ionizing radiation and lower incidence of contrast reactions. We evaluated 3.0T MRA for assessing renal anatomy of LRDs. Thirty consecutive LRDs underwent CTA followed by 3.0T MRA. Data points included number and branching of vessels, incidental findings, and urothelial opacification. Studies were individually evaluated by three readers blinded to patient data. Studies were reevaluated in consensus with discrepancies revealed, and final consensus results were labeled "truth". Compared with consensus "truth", both computed tomography (CT) and magnetic resonance imaging were highly accurate for assessment of arterial and venous anatomy, although CT was superior for detection of late venous confluence as well as detection of renal stones. Both modalities were comparable in opacification of lower ureters and bladder; MRA underperformed CTA for opacification of upper urinary tracts. 3.0T MRA enabled excellent detection of comprehensive renal anatomy compared to CTA in LRDs. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. [Acute limb ischemia from the general surgeon's point of view. How much knowledge of vascular surgery is necessary?].

    PubMed

    Kopp, R; Weidenhagen, R; Hornung, H; Jauch, K W; Lauterjung, L

    2003-12-01

    The diagnosis of acute peripheral ischemia can be obtained based on clinical presentation, inspection, and palpation of the affected extremity. Unfractionated heparin as a single shot is immediately given followed by continuous infusion when diagnosis is clinically evident and contraindications are excluded. Thromboembolectomy using a Fogarty catheter is immediately performed in patients with evidence of arterial embolization and signs of advanced ischemia (TASC IIb/III) followed by intraoperative angiography. Patients with evidence of arterial thrombosis require urgent angiography followed by thrombectomy and probably subsequent endovascular or surgical interventions and vascular reconstruction. For patients with moderate ischemia (TASC IIa), initial diagnostic angiography is recommended followed by primary thrombectomy with subsequent intraoperative angiography and immediate endovascular or operative treatment of remaining vascular problems. As an alternative therapeutic option initial catheter-guided local thrombolysis can be performed in selected patients with the intention of subsequent limb revascularization or unmasking relevant vessel alterations leading to specific endovascular or surgically performed vascular reconstruction. Possible development of muscle ischemia because of increased compartment pressure should be considered and fasciotomy performed when indicated. Primary amputation of the severely ischemic limb after initial thrombectomy might be recommended in patients with life-threatening organ failure related to muscle necrosis.

  15. Noninvasive coronary artery angiography using electron beam computed tomography

    NASA Astrophysics Data System (ADS)

    Rumberger, John A.; Rensing, Benno J.; Reed, Judd E.; Ritman, Erik L.; Sheedy, Patrick F., II

    1996-04-01

    Electron beam computed tomography (EBCT), also known as ultrafast-CT or cine-CT, uses a unique scanning architecture which allows for multiple high spatial resolution electrocardiographic triggered images of the beating heart. A recent study has demonstrated the feasibility of qualitative comparisons between EBCT derived 3D coronary angiograms and invasive angiography. Stenoses of the proximal portions of the left anterior descending and right coronary arteries were readily identified, but description of atherosclerotic narrowing in the left circumflex artery (and distal epicardial disease) was not possible with any degree of confidence. Although these preliminary studies support the notion that this approach has potential, the images overall were suboptimal for clinical application as an adjunct to invasive angiography. Furthermore, these studies did not examine different methods of EBCT scan acquisition, tomographic slice thicknesses, extent of scan overlap, or other segmentation, thresholding, and interpolation algorithms. Our laboratory has initiated investigation of these aspects and limitations of EBCT coronary angiography. Specific areas of research include defining effects of cardiac orientation; defining the effects of tomographic slice thickness and intensity (gradient) versus positional (shaped based) interpolation; and defining applicability of imaging each of the major epicardial coronary arteries for quantitative definition of vessel size, cross-sectional area, taper, and discrete vessel narrowing.

  16. Variations in the origins of the thyroid arteries on CT angiography.

    PubMed

    Esen, Kaan; Ozgur, Anil; Balci, Yuksel; Tok, Sermin; Kara, Engin

    2018-02-01

    To investigate the anatomical variations in the origins of the thyroid arteries on CT angiography images. The presence and the origins of the superior thyroid artery, the inferior thyroid artery, and the thyroidea ima artery were retrospectively evaluated based on carotid CT angiography examinations. The bifurcation level of the common carotid artery with respect to the cervical vertebrae and disc spaces was also determined. A total of 640 patients were included in the study. The right and left superior thyroid arteries arose from the external carotid artery in 413 (64.5%) and 254 (39.7%) patients, from the bifurcation of the common carotid artery in 131 (20.5%) and 148 (23.1%) patients, and from the common carotid artery in 90 (14.1%) and 226 (35.3%) patients, respectively. We could not observe the right and the left superior thyroid arteries in 6 (0.9%) and 12 (1.9%) of the patients, respectively. However, the right and left inferior thyroid arteries were not identified in 14 (2.2%) and 45 (7%) of the patients, respectively. The thyroidea ima artery was detected in 2.3% of the patients. The visualization of thyroid arteries on CT angiography images enables the anatomy of the arterial supply system of the thyroid gland to be explored in a noninvasive manner prior to surgery.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young Il; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr; Kim, Hyun Beom

    PurposeThis study was designed to investigate the effects of stenting across the branching arteries on the patency and stent-tissue responses over the branching arterial orifices. Methods: Thirteen dogs were observed after placing aortic stents across the celiac arteries (CA), superior mesenteric arteries (SMA), and renal arteries (RA). The animals were grouped according to stent types: large-cell group (n = 6) and small-cell group (n = 7). Angiography was performed to evaluate the branching artery patency at 2, 6, and 12 months after stent insertion, and the stent-tissue responses covering the orifices were evaluated on histopathologic examination. Results: All branching arteriesmore » were patent on follow-up angiography; however, three patterns of stent-tissue responses over the orifices were observed: neointimal layering, bridging septa, and papillary hyperplasia. Although neointimal layering and bridging septa were evenly observed, severe papillary hyperplasia was more frequent at SMA and CA than RA. Four RA showed less than 50% ostial patency, and localized infarct was observed in six kidneys (24%). The ostial patency tended to decrease with small-cell stent during the follow-up period. Conclusions: Various stent-tissue responses over the branching artery orifices are induced by the aortic stent covering the branching arteries and may not be easily detected by conventional angiography. Subclinical renal infarct also may occur despite patent renal angiography.« less

  18. Imaging of acute and chronic thromboembolic disease: state of the art.

    PubMed

    Ruggiero, A; Screaton, N J

    2017-05-01

    Acute pulmonary embolism (PE) is a life-threatening condition that requires prompt diagnosis and treatment. Recent advances in imaging allow acute and rapid recognition even by the non-specialist radiologist. Most acute emboli resolve on anticoagulation without sequelae; however, some emboli fail to fully resolve becoming endothelialised with the development of chronic thromboembolic disease (CTED). Increased pulmonary vascular resistance arising from CTED may lead to chronic thromboembolic pulmonary hypertension (CTEPH) a debilitating disease affecting up to 5% of survivors of acute PE. Diagnostic evaluation is more complex in CTEPH/CTED than acute PE with subtle imaging features often being overlooked or misinterpreted. Differentiation of acute from chronic PE and from other forms of pulmonary hypertension has profound therapeutic implications. Diverse imaging techniques are available to diagnose and monitor PEs both in the acute and chronic setting. Broadly they include techniques that provide data on lung parenchymal perfusion (ventilation-perfusion [VQ] scintigraphy), angiographic techniques (computed tomography [CT], magnetic resonance imaging [MRI], and invasive angiography) or a combination of both (MR angiography and time-resolved angiography or dual-energy CT angiography). This review aims to describe state of the art imaging highlighting the strength and weaknesses of individual techniques in the diagnosis of acute and chronic PE. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  19. Scalable wide-field optical coherence tomography-based angiography for in vivo imaging applications

    PubMed Central

    Xu, Jingjiang; Wei, Wei; Song, Shaozhen; Qi, Xiaoli; Wang, Ruikang K.

    2016-01-01

    Recent advances in optical coherence tomography (OCT)-based angiography have demonstrated a variety of biomedical applications in the diagnosis and therapeutic monitoring of diseases with vascular involvement. While promising, its imaging field of view (FOV) is however still limited (typically less than 9 mm2), which somehow slows down its clinical acceptance. In this paper, we report a high-speed spectral-domain OCT operating at 1310 nm to enable wide FOV up to 750 mm2. Using optical microangiography (OMAG) algorithm, we are able to map vascular networks within living biological tissues. Thanks to 2,048 pixel-array line scan InGaAs camera operating at 147 kHz scan rate, the system delivers a ranging depth of ~7.5 mm and provides wide-field OCT-based angiography at a single data acquisition. We implement two imaging modes (i.e., wide-field mode and high-resolution mode) in the OCT system, which gives highly scalable FOV with flexible lateral resolution. We demonstrate scalable wide-field vascular imaging for multiple finger nail beds in human and whole brain in mice with skull left intact at a single 3D scan, promising new opportunities for wide-field OCT-based angiography for many clinical applications. PMID:27231630

  20. Comparison between wide-angle OCT angiography and ultra-wide field fluorescein angiography for detecting non-perfusion areas and retinal neovascularization in eyes with diabetic retinopathy.

    PubMed

    Sawada, Osamu; Ichiyama, Yusuke; Obata, Syunpei; Ito, Yuka; Kakinoki, Masashi; Sawada, Tomoko; Saishin, Yoshitsugu; Ohji, Masahito

    2018-04-30

    To compare the ability of wide-angle optical coherence tomography angiography (OCTA) with that of ultra-wide field fluorescein angiography (UWFFA) to detect non-perfusion areas (NPAs) or retinal neovascularization (NV) in eyes with diabetic retinopathy (DR). Patients with DR underwent UWFFA using the Optos® panoramic 200Tx imaging system and wide-angle OCTA with 12 × 12 mm fields of five visual fixations using the PLEX Elite 9000®. We compared the abilities of UWFFA and OCTA to detect NPAs and NV. Fifty-eight eyes of 33 patients (mean age, 60.0 years old; female/male, 16/17) with DR were evaluated. NPAs were detected in 47 out of 58 eyes using UWFFA and in 48 eyes using OCTA. NVs were detected in 25 out of the 58 eyes using UWFFA and in 26 eyes using OCTA. The sensitivity for detection of NPA using OCTA was 0.98, and the specificity was 0.82. The sensitivity for detection of NV was 1.0, and the specificity was 0.97. The wide-angle OCTA seems to be clinically useful for the detection of NPAs or NV.

Top