Science.gov

Sample records for anterior edge acrylic

  1. The anterior centre-edge angle. A cadaver study.

    PubMed

    Crockarell, J R; Trousdale, R T; Guyton, J L

    2000-05-01

    The anterior centre-edge (VCA) angle quantifies the anterior cover of the femoral head, and angles of less than 20 degrees are considered abnormal. We have measured the VCA angles in hips without osteoarthritic changes. We took bilateral false-profile radiographs of nine female and 30 male cadavers without signs of osteoarthritis. The mean age at the time of death was 72 years (46 to 92). The mean VCA angle was 32.8 degrees (17.7 to 53.6). The SD was 7.9 degrees. Our findings suggest that the threshold of abnormality of the VCA angle may be slightly lower than previously thought. This information may be useful in counselling patients with asymptomatic acetabular dysplasia.

  2. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients

    PubMed Central

    Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng

    2015-01-01

    AIM To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. METHODS Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. RESULTS There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. CONCLUSION For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. PMID:26309870

  3. Discrepancies in measuring acetabular coverage: revisiting the anterior and lateral center edge angles

    PubMed Central

    Hanson, Joey A.; Kapron, Ashley L.; Swenson, Kathryn M.; Maak, Travis G.; Peters, Christopher L.; Aoki, Stephen K.

    2015-01-01

    The lateral center edge angle (LCEA) and the anterior center edge angle (ACEA) are commonly used to assess acetabular coverage of the femoral head. There are two distinct methods found in the literature to obtain these angles, specifically, measuring to the most lateral bone edge versus the sclerotic lateral sourcil edge. A difference between these two methods may contribute to inconsistent estimates of acetabular coverage, and potentially lead to clinical misdiagnosis and treatment mismanagement. The objectives of this study were to quantify the difference between bone edge and sourcil edge measurements and to determine how the difference influences the classification of acetabular coverage in adult patients with suspected hip pathomorphology. Two observers completed the measurements independently using preoperative anteroposterior and false profile radiographs. Bland–Altman plots and paired t-tests were used to compare measurement methods. Bone and sourcil measurements of the LCEA and ACEA were significantly different (both P < 0.001). On average, the bone LCEA was 4° (95% limits of agreement = −2° to 10°) greater than the sourcil LCEA. The bone ACEA was, on average, 10° (95% limit of agreement = −2° to 22°) greater than the sourcil ACEA. The differences often led to different clinical classifications for the same hip. With a statistically and clinically significant difference in the quantification of acetabular coverage using bone edge versus sourcil edge methods for measuring the LCEA and ACEA in adult patients, it should be mandatory to clearly identify which method was used in each study. PMID:27011850

  4. Evaluation of Proportion between Incisal Edge to Gingival Zenith Distance and Interdental Papilla in Maxillary Anterior Dentition of Indian Population

    PubMed Central

    Damodaran, Anand; Balasubramanium, Muthukumar

    2016-01-01

    Introduction Not many investigations have evaluated the relationship between the height of the interdental papillae, gingival zenith and maxillary anterior teeth. The assessment of these parameters can aid in fabricating definitive aesthetic restoration. Aim The aim of this study was to evaluate the existence of proportional ratio between the incisal edge to gingival zenith (HGZ) and the tip of the interdental papilla (HIP) in maxillary anterior teeth for Indian population. Materials and Methods One hundred healthy volunteers with an average age of 25-30 years comprised the evaluation group. Impression was made using irreversible hydrocolloid impression material and type IV Dental stone cast was made. A calibrated digital caliper measured the distance between HGZ and HIP. The values for all six maxillary teeth were recorded and the proportional ratio was evaluated and statistically analysed. Results The mean ratio between HGZ and HIP of all maxillary anteriors in 1st and 2nd quadrant was 1.80, 1.71, and 2.03 in central incisor, lateral incisor and canine respectively with p-value > 0.9. Conclusion The mean proportional measurements for maxillary anterior teeth were determined and no definitive proportion existed between HGZ and HIP of maxillary anterior teeth. PMID:27134999

  5. Dentulous appliance for upper anterior edentulous span.

    PubMed

    Chalakkal, Paul; Devi, Ramisetty Sabitha; Srinivas, G Vijay; Venkataramana, Pammi

    2013-12-01

    This article discusses about a fixed dentulous appliance that was constructed to replace the primary upper anterior edentulous span in a four year old girl. It constituted a design, whereby the maxillary primary second molars were used to support the appliance through bands and a wire that contained an acrylic flange bearing trimmed acrylic teeth, anteriorly. The appliance was functionally and aesthetically compliant.

  6. Acrylic acid

    Integrated Risk Information System (IRIS)

    Acrylic acid ( CASRN 79 - 10 - 7 ) Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff

  7. Methyl acrylate

    Integrated Risk Information System (IRIS)

    Methyl acrylate ; CASRN 96 - 33 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Ef

  8. Dentulous Appliance for Upper Anterior Edentulous Span

    PubMed Central

    Chalakkal, Paul; Devi, Ramisetty Sabitha; Srinivas, G. Vijay; Venkataramana, Pammi

    2013-01-01

    This article discusses about a fixed dentulous appliance that was constructed to replace the primary upper anterior edentulous span in a four year old girl. It constituted a design, whereby the maxillary primary second molars were used to support the appliance through bands and a wire that contained an acrylic flange bearing trimmed acrylic teeth, anteriorly. The appliance was functionally and aesthetically compliant. PMID:24551736

  9. Acrylate Systemic Contact Dermatitis.

    PubMed

    Sauder, Maxwell B; Pratt, Melanie D

    2015-01-01

    Acrylates, the 2012 American Contact Dermatitis Society allergen of the year, are found in a range of products including the absorbent materials within feminine hygiene pads. When fully polymerized, acrylates are nonimmunogenic; however, if not completely cured, the monomers can be potent allergens.A 28-year-old woman is presented, who had her teeth varnished with Isodan (Septodont, Saint-Maur-des-Fossés, France) containing HEMA (2-hydroxyethyl methacrylate) with no initial reaction. Approximately 1 month later, the patient developed a genital dermatitis secondary to her feminine hygiene pads. The initial reaction resolved, but 5 months later, the patient developed a systemic contact dermatitis after receiving a second varnishing.The patient was dramatically patch test positive to many acrylates. This case demonstrates a reaction to likely unpolymerized acrylates within a feminine hygiene pad, as well as broad cross-reactivity or cosensitivity to acrylates, and possibly a systemic contact dermatitis with systemic re-exposure to unpolymerized acrylates.

  10. Acrylic vessel cleaning tests

    SciTech Connect

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-02-26

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory.

  11. Acrylic purification and coatings

    NASA Astrophysics Data System (ADS)

    Kuźniak, Marcin

    2011-04-01

    Radon (Rn) and its decay daughters are a well-known source of background in direct WIMP detection experiments, as either a Rn decay daughter or an alpha particle emitted from a thin inner surface layer of a detector could produce a WIMP-like signal. Different surface treatment and cleaning techniques have been employed in the past to remove this type of contamination. A new method of dealing with the problem has been proposed and used for a prototype acrylic DEAP-1 detector. Inner surfaces of the detector were coated with a layer of ultra pure acrylic, meant to shield the active volume from alphas and recoiling nuclei. An acrylic purification technique and two coating techniques are described: a solvent-borne (tested on DEAP-1) and solvent-less (being developed for the full scale DEAP-3600 detector).

  12. Acrylic purification and coatings

    SciTech Connect

    Kuzniak, Marcin

    2011-04-27

    Radon (Rn) and its decay daughters are a well-known source of background in direct WIMP detection experiments, as either a Rn decay daughter or an alpha particle emitted from a thin inner surface layer of a detector could produce a WIMP-like signal. Different surface treatment and cleaning techniques have been employed in the past to remove this type of contamination. A new method of dealing with the problem has been proposed and used for a prototype acrylic DEAP-1 detector. Inner surfaces of the detector were coated with a layer of ultra pure acrylic, meant to shield the active volume from alphas and recoiling nuclei. An acrylic purification technique and two coating techniques are described: a solvent-borne (tested on DEAP-1) and solvent-less (being developed for the full scale DEAP-3600 detector).

  13. Acrylic mechanical bond tests

    SciTech Connect

    Wouters, J.M.; Doe, P.J.

    1991-02-01

    The tensile strength of bonded acrylic is tested as a function of bond joint thickness. 0.125 in. thick bond joints were found to posses the maximum strength while the acceptable range of joints varied from 0.063 in. to almost 0.25 in. Such joints are used in the Sudbury Neutrino Observatory.

  14. Edge shape and comfort of rigid lenses.

    PubMed

    La Hood, D

    1988-08-01

    One of the main factors determining the comfort of a rigid contact lens is the shape of the edge. The comfort of four different contact lens edge shapes was assessed with four unadapted subjects in a randomized masked trial. Lenses with well rounded anterior edge profiles were found to be significantly more comfortable than lenses with square anterior edges. There was no significant difference in subjective comfort between a rounded and square posterior edge profile. The results suggest that the interaction of the edge with the eyelid is more important in determining comfort than edge effects on the cornea, when lenses are fitted according to a corneal alignment philosophy. PMID:3177585

  15. 21 CFR 177.1010 - Acrylic and modified acrylic plastics, semirigid and rigid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Acrylic and modified acrylic plastics, semirigid... Acrylic and modified acrylic plastics, semirigid and rigid. Semirigid and rigid acrylic and modified acrylic plastics may be safely used as articles intended for use in contact with food, in accordance...

  16. 21 CFR 177.1010 - Acrylic and modified acrylic plastics, semirigid and rigid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Acrylic and modified acrylic plastics, semirigid... Acrylic and modified acrylic plastics, semirigid and rigid. Semirigid and rigid acrylic and modified acrylic plastics may be safely used as articles intended for use in contact with food, in accordance...

  17. 21 CFR 177.1010 - Acrylic and modified acrylic plastics, semirigid and rigid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Acrylic and modified acrylic plastics, semirigid... Acrylic and modified acrylic plastics, semirigid and rigid. Semirigid and rigid acrylic and modified acrylic plastics may be safely used as articles intended for use in contact with food, in accordance...

  18. [Acrylic resin removable partial dentures].

    PubMed

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  19. Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

    PubMed Central

    2016-01-01

    PURPOSE This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05). RESULTS The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth. PMID:27555897

  20. Bonding auto-polymerising acrylic resin to acrylic denture teeth.

    PubMed

    Nagle, Susan; Ray, Noel J; Burke, Francis M; Gorman, Catherine M

    2009-09-01

    This study investigated the effect of surface treatments on the shear bond strength of an auto-polymerising acrylic resin cured to acrylic denture teeth. The surface treatments included a combination of grit-blasting and/or wetting the surface with monomer. Samples were prepared and then stored in water prior to shear testing. The results indicated that the application of monomer to the surface prior to bonding did not influence the bond strength. Grit blasting was found to significantly increase the bond strength. PMID:19839190

  1. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under...

  2. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under...

  3. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under...

  4. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under...

  5. Mixing It Up with Acrylics.

    ERIC Educational Resources Information Center

    Laird, Shirley

    1999-01-01

    Presents an art activity for fifth-grade students in which they learn about basic shapes and what happens when shapes overlap, draw seven overlapping geometric shapes, review the use of acrylic paint and mixing colors, and finally paint with primary colors. (CMK)

  6. A method for preparing sodium acrylate-d3, a useful and stable precursor for deuterated acrylic monomers

    SciTech Connect

    Yang, Jun; Hong, Kunlun; Bonnesen, Peter V

    2011-01-01

    A convenient and economical method for converting propiolic acid to sodium acrylate-d3 is described. Successive D/H exchange of the alkyne proton of sodium propiolate (prepared from propiolic acid) using D2O affords sodium propiolate-d having up to 99 atom% D. Sodium propiolate-d can be partially reduced to sodium acrylate-d3 with 90% conversion and 89% yield, using D2 and the Lindlar catalyst with control of reaction parameters to maximize conversion while minimizing over reduction.

  7. Esterification of acrylic acid with methanol

    SciTech Connect

    Chubarov, G.A.; Danov, S.M.; Logutov, V.I.; Obmelyukhina, T.N.

    1984-01-01

    The esterification of acrylic acid with methanol in the absence of catalysis by strong mineral acids has been studied. The esterification rate was estimated from the amount of methyl acrylate formed at the end of a definite time, and the reaction rate was found to be first order with respect to methanol and second order with respect to acrylic acid. Mathematical relationships in good agreement with experimental data were derived from the results of the kinetic studies.

  8. Edge Bioinformatics

    SciTech Connect

    Lo, Chien-Chi

    2015-08-03

    Edge Bioinformatics is a developmental bioinformatics and data management platform which seeks to supply laboratories with bioinformatics pipelines for analyzing data associated with common samples case goals. Edge Bioinformatics enables sequencing as a solution and forward-deployed situations where human-resources, space, bandwidth, and time are limited. The Edge bioinformatics pipeline was designed based on following USE CASES and specific to illumina sequencing reads. 1. Assay performance adjudication (PCR): Analysis of an existing PCR assay in a genomic context, and automated design of a new assay to resolve conflicting results; 2. Clinical presentation with extreme symptoms: Characterization of a known pathogen or co-infection with a. Novel emerging disease outbreak or b. Environmental surveillance

  9. Edge Bioinformatics

    2015-08-03

    Edge Bioinformatics is a developmental bioinformatics and data management platform which seeks to supply laboratories with bioinformatics pipelines for analyzing data associated with common samples case goals. Edge Bioinformatics enables sequencing as a solution and forward-deployed situations where human-resources, space, bandwidth, and time are limited. The Edge bioinformatics pipeline was designed based on following USE CASES and specific to illumina sequencing reads. 1. Assay performance adjudication (PCR): Analysis of an existing PCR assay in amore » genomic context, and automated design of a new assay to resolve conflicting results; 2. Clinical presentation with extreme symptoms: Characterization of a known pathogen or co-infection with a. Novel emerging disease outbreak or b. Environmental surveillance« less

  10. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. Link to an amendment published at 79 FR 34637, June 18, 2014. (a) Chemical substance and... ester (PMN P-96-824) is subject to reporting under this section for the significant new uses...

  11. Hydrophilic Acrylic versus PMMA Intraocular Lens Implantation in Pediatric Cataract Surgery

    PubMed Central

    Panahi-Bazaz, Mahmoud-Reza; Zamani, Mitra; Abazar, Bijan

    2009-01-01

    Purpose To compare primary implantation of foldable hydrophilic acrylic with polymethylmethacrylate (PMMA) intraocular lenses (IOLs) in pediatric cataract surgery in terms of short-term complications and visual outcomes. Methods This randomized clinical trial included 40 eyes of 31 consecutive pediatric patients aged 1 to 6 years with unilateral or bilateral congenital cataracts undergoing cataract surgery with primary IOL implantation. Two types of IOLs including foldable hydrophilic acrylic and rigid PMMA were randomly implanted in the capsular bag during surgery. Primary posterior capsulotomy and anterior vitrectomy were performed in all eyes. Patients were followed for at least 1 year. Intra- and postoperative complications, visual outcomes and refractive errors were compared between the study groups. Results Mean age was 3.2±1.8 years in the hydrophilic acrylic group and 3.7±1.3 years in the PMMA group. Mean follow-up period was 19.6±5 (12–29) months. No intraoperative complication occurred in any group. Postoperative uveitis was seen in 2 (10%) eyes in the acrylic group versus 5 (25%) eyes in the PMMA group (P=0.40). Other postoperative complications including pigment deposition (30%), iridocorneal adhesions (10%) and posterior synechiae formation (10%), were seen only in the PMMA group. The visual axis remained completely clear and visual outcomes were generally favorable and comparable in the study groups. Conclusion In pediatric eyes undergoing lensectomy with primary posterior capsulotomy and anterior vitrectomy, hydrophilic acrylic IOLs are comparable to PMMA IOLs in terms of biocompatibility and visual axis clarity, and seem to entail less frequent postoperative complications. PMID:23198075

  12. Radiopurity measurement of acrylic for DEAP-3600

    SciTech Connect

    Nantais, C. M.; Boulay, M. G.; Cleveland, B. T.

    2013-08-08

    The spherical acrylic vessel that contains the liquid argon target is the most critical detector component in the DEAP-3600 dark matter experiment. Alpha decays near the inner surface of the acrylic vessel are one of the main sources of background in the detector. A fraction of the alpha energy, or the recoiling nucleus from the alpha decay, could misreconstruct in the fiducial volume and result in a false candidate dark matter event. Acrylic has low levels of inherent contamination from {sup 238}U and {sup 232}Th. Another background of particular concern is diffusion of {sup 222}Rn during manufacturing, leading to {sup 210}Pb contamination. The maximum acceptable concentrations in the DEAP-3600 acrylic vessel are ppt levels of {sup 238}U and {sup 232}Th equivalent, and 10{sup −8} ppt {sup 210}Pb. The impurities in the bulk acrylic will be measured by vaporizing a large quantity of acrylic and counting the concentrated residue with ultra-low background HPGe detectors and a low background alpha spectrometer. An overview of the acrylic assay technique is presented.

  13. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid... for use in contact with food subject to the provisions of this section. (a) The ethylene-acrylic...

  14. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be...) Acrylamide-acrylic acid resins are produced by the polymerization of acrylamide with partial hydrolysis or...

  15. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the...

  16. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the...

  17. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the...

  18. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic...) Identity. For the purpose of this section, n-alkylglutarimide/acrylic copolymers are copolymers obtained...

  19. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the...

  20. A Study on Effect of Surface Treatments on the Shear Bond Strength between Composite Resin and Acrylic Resin Denture Teeth.

    PubMed

    Chatterjee, Nirmalya; Gupta, Tapas K; Banerjee, Ardhendu

    2011-03-01

    Visible light-cured composite resins have become popular in prosthetic dentistry for the replacement of fractured/debonded denture teeth, making composite denture teeth on partial denture metal frameworks, esthetic modification of denture teeth to harmonize with the characteristics of adjacent natural teeth, remodelling of worn occlusal surfaces of posterior denture teeth etc. However, the researches published on the bond strength between VLC composite resins and acrylic resin denture teeth is very limited. The purpose of this study is to investigate the effect of five different methods of surface treatments on acrylic resin teeth on the shear bond strength between light activated composite resin and acrylic resin denture teeth. Ninety cylindrical sticks of acrylic resin with denture teeth mounted atop were prepared. Various treatments were done upon the acrylic resin teeth surfaces. The samples were divided into six groups, containing 15 samples each. Over all the treated and untreated surfaces of all groups, light-cured composite resin was applied. The shear strengths were measured in a Universal Testing Machine using a knife-edge shear test. Data were analyzed using one way analysis of variance (ANOVA) and mean values were compared by the F test. Application of bonding agent with prior treatment of methyl methacrylate on the acrylic resin denture teeth resulted in maximum bond strength with composite resin.

  1. Crystal structure transformation in potassium acrylate

    NASA Astrophysics Data System (ADS)

    Pai Verneker, V. R.; Vasanthakumari, R.

    1983-10-01

    Potassium acrylate undergoes a reversible phase transformation around 335°K with an activation energy of 133 kcal/mole. Differential scanning calorimetry and high temperature X-ray powder diffraction techniques have been used to probe this phenomenon.

  2. Encapsulation of photocells with acrylic prepolymer

    SciTech Connect

    Avenel, M.; Evrard, P.; Leca, J.-P.

    1985-10-22

    Acrylic prepolymer comprising: from 10 to 50% by weight of units derived from at least one alkyl acrylate, the alkyl group having from 4 to 12 carbon atoms, from 30 to 60% by weight of units derived from at least one alkyl methacrylate, the alkyl group having from 1 to 5 carbon atoms, and from 10 to 40% by weight of units derived from methyl acrylate. The prepolymer is used to encapsulate photocells, connected to one another by conducting wires and positioned on a support plate, by casting a resin into the space located between the support plate and a second protective plate, the resin being obtained by mixing 100 parts of the acrylic prepolymer, from 0.1 to 4 parts of a vanadium arenesulphonate and from 0.5 to 4 parts of a free-radical initiator, at a temperature between 10 and 70 C. and for a sufficient time to solidify the polymeric resin at the temperature selected.

  3. Edge detection

    NASA Astrophysics Data System (ADS)

    Hildreth, E. C.

    1985-09-01

    For both biological systems and machines, vision begins with a large and unwieldly array of measurements of the amount of light reflected from surfaces in the environment. The goal of vision is to recover physical properties of objects in the scene such as the location of object boundaries and the structure, color and texture of object surfaces, from the two-dimensional image that is projected onto the eye or camera. This goal is not achieved in a single step: vision proceeds in stages, with each stage producing increasingly more useful descriptions of the image and then the scene. The first clues about the physical properties of the scene are provided by the changes of intensity in the image. The importance of intensity changes and edges in early visual processing has led to extensive research on their detection, description and use, both in computer and biological vision systems. This article reviews some of the theory that underlies the detection of edges, and the methods used to carry out this analysis.

  4. Comparative evaluation of shear compressive bond strength between cross-linked acrylic resin denture base and cross-linked acrylic resin teeth with different modifcations of their ridge lap surfaces.

    PubMed

    Sadar, Leena; Dhume, Swaroop; Maniar, Neena; Prakash Patil, Jeevan; Rane, Prasad; Gandhewar, Mahesh

    2013-09-01

    A major problem commonly observed in denture wearer is the detachment of artifcial tooth/teeth from acrylic denture base. The problem was grave when porcelain teeth used along with the then available denture base materials. The bond formed was purely mechanical and hence debonding of teeth from denture base was a frequent occurrence. Inspite of chemical union between acrylic resin teeth and acrylic denture base material, detachment of teeth particularly anterior teeth is a frequent observation. The objective of the study is to study the effect of change in the surface treatment and surface confguration of ridge lap surface of the teeth on retention of cross-linked acrylic teeth on cross-linked acrylic resin denture base. Sixty specimens were tested for the shear compressive bond strength using instron universal testing machine in KN. Statistical analysis is used. The fndings were analyzed using one-way analysis of variance (ANOVA) and 't' test. Slight modifcation in the ridge lap surface of artifcial teeth alters the strength of the shear compressive bond. Sand papering of ridge lap surfaces improves the shear compressive bond then the one without any modifcation. Maximum shear compressive bond strength can be increased by application of monomer.

  5. Bilateral Anterior Shoulder Dislocation

    PubMed Central

    Siu, Yuk Chuen; Lui, Tun Hing

    2014-01-01

    Introduction: Unilateral anterior shoulder dislocation is one of the most common problems encountered in orthopedic practice. However, simultaneous bilateral anterior dislocation of the shoulders is quite rare. Case Presentation: We report a case of a 75-year-old woman presented with simultaneous bilateral anterior shoulder dislocation following a trauma, complicated with a traction injury to the posterior cord of the brachial plexus. Conclusions: Bilateral anterior shoulder dislocation is very rare. The excessive traction force during closed reduction may lead to nerve palsy. Clear documentation of neurovascular status and adequate imaging before and after a reduction should be performed. PMID:25685749

  6. Spontaneous dislocation of lens bag with acrylic lens after uneventful cataract surgery – unusual complication of cataract surgery

    PubMed Central

    Shah, Mehul A.; Shah, Shreya M.; Mehta, Ruchir; Shah, Prerna

    2015-01-01

    Introduction: Spontaneous dislocation of intraocular lens with bag is rare. Methods: We report a case of a 56-year-old male who presented with spontaneous anterior dislocation of an in-the-bag intraocular lens 3 years after manual small incision cataract surgery. He had undergone manual small incision cataract surgery with foldable acrylic intraocular lens implantation, and 18 months after cataract surgery ND: YAG capsulotomy with uneventful post capsulotomy follow-up. 17 months after capsulotomy, the patient presented with sudden decrease of vision. On anterior segment examination, the intraocular lens with bag was dislocated into the anterior chamber. Result: It was managed with intraocular lens explantation with bag, anterior vitrectomy and sclera fixated intraocular lens. Conclusion: Spontaneous intraocular lens dislocation with bag is possible after 1.5 years of uneventful surgery which may be managed using different techniques. PMID:27625955

  7. Allergic contact dermatitis to acrylates in disposable blue diathermy pads.

    PubMed Central

    Sidhu, S. K.; Shaw, S.

    1999-01-01

    We report 2 cases of elicitation of allergic contact dermatitis to acrylates from disposable blue diathermy pads used on patients who underwent routine surgery. Their reactions were severe, and took approximately 5 weeks to resolve. Both patients gave a prior history of finger tip dermatitis following the use of artificial sculptured acrylic nails, which is a common, but poorly reported, cause of acrylate allergy. Patch testing subsequently confirmed allergies to multiple acrylates present in both the conducting gel of disposable blue diathermy pads, and artificial sculptured acrylic nails. We advocate careful history taking prior to surgery to avoid unnecessary exposure to acrylates in patients already sensitized. Images Figure 1 Figure 2 PMID:10364952

  8. The Edge

    NASA Technical Reports Server (NTRS)

    2006-01-01

    6 April 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows the edge (running diagonally from the lower left to the upper right) of a trough, which is part of a large pit crater complex in Noachis Terra. This type of trough forms through the collapse of surface materials into the subsurface, and often begins as a series of individual pit craters. Over time, continued collapse increases the diameter of individual pits until finally, adjacent pits merge to form a trough such as the one captured in this image. The deep shadowed area is caused in part by an overhang; layered rock beneath this overhang is less resistant to erosion, and thus has retreated tens of meters backward, beneath the overhang. A person could walk up inside this 'cave' formed by the overhanging layered material.

    Location near: 47.0oS, 355.7oW Image width: 3 km (1.9 mi) Illumination from: upper left Season: Southern Summer

  9. Unified EDGE

    SciTech Connect

    2007-06-18

    UEDGE is an interactive suite of physics packages using the Python or BASIS scripting systems. The plasma is described by time-dependent 2D plasma fluid equations that include equations for density, velocity, ion temperature, electron temperature, electrostatic potential, and gas density in the edge region of a magnetic fusion energy confinement device. Slab, cylindrical, and toroidal geometries are allowed, and closed and open magnetic field-line regions are included. Classical transport is assumed along magnetic field lines, and anomalous transport is assumed across field lines. Multi-charge state impurities can be included with the corresponding line-radiation energy loss. Although UEDGE is written in Fortran, for efficient execution and analysis of results, it utilizes either Python or BASIS scripting shells. Python is easily available for many platforms (http://www.Python.org/). The features and availability of BASIS are described in “Basis Manual Set” by P.F. Dubois, Z.C. Motteler, et al., Lawrence Livermore National Laboratory report UCRL-MA-1 18541, June, 2002 and http://basis.llnl.gov. BASIS has been reviewed and released by LLNL for unlimited distribution. The Python version utilizes PYBASIS scripts developed by D.P. Grote, LLNL. The Python version also uses MPPL code and MAC Perl script, available from the public-domain BASIS source above. The Forthon version of UEDGE uses the same source files, but utilizes Forthon to produce a Python-compatible source. Forthon has been developed by D.P. Grote at LBL (see http://hifweb.lbl.gov/Forthon/ and Grote et al. in the references below), and it is freely available. The graphics can be performed by any package importable to Python, such as PYGIST.

  10. Unified EDGE

    2007-06-18

    UEDGE is an interactive suite of physics packages using the Python or BASIS scripting systems. The plasma is described by time-dependent 2D plasma fluid equations that include equations for density, velocity, ion temperature, electron temperature, electrostatic potential, and gas density in the edge region of a magnetic fusion energy confinement device. Slab, cylindrical, and toroidal geometries are allowed, and closed and open magnetic field-line regions are included. Classical transport is assumed along magnetic field lines,more » and anomalous transport is assumed across field lines. Multi-charge state impurities can be included with the corresponding line-radiation energy loss. Although UEDGE is written in Fortran, for efficient execution and analysis of results, it utilizes either Python or BASIS scripting shells. Python is easily available for many platforms (http://www.Python.org/). The features and availability of BASIS are described in “Basis Manual Set” by P.F. Dubois, Z.C. Motteler, et al., Lawrence Livermore National Laboratory report UCRL-MA-1 18541, June, 2002 and http://basis.llnl.gov. BASIS has been reviewed and released by LLNL for unlimited distribution. The Python version utilizes PYBASIS scripts developed by D.P. Grote, LLNL. The Python version also uses MPPL code and MAC Perl script, available from the public-domain BASIS source above. The Forthon version of UEDGE uses the same source files, but utilizes Forthon to produce a Python-compatible source. Forthon has been developed by D.P. Grote at LBL (see http://hifweb.lbl.gov/Forthon/ and Grote et al. in the references below), and it is freely available. The graphics can be performed by any package importable to Python, such as PYGIST.« less

  11. 21 CFR 173.5 - Acrylate-acrylamide resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... additive consists of one of the following: (1) Acrylamide-acrylic acid resin (hydrolyzed polyacrylamide) is... and acrylic acid, with the greater part of the polymer being composed of acrylamide units. (2)...

  12. [Incomplete anterior interosseous nerve syndrome in a guitar player].

    PubMed

    Rieck, B

    2005-12-01

    A rare case of median nerve compression syndrome is reported in a guitar player who had changed the posture and position of his instrument so that the edge of the guitar exerted sharp pressure on the median nerve close to the branching of the interosseous anterior nerve. There was partial paralysis of the interosseous anterior nerve with complete failure of the deep flexor of the index finger, while the flexor pollicis longus was intact. There was also paresthesia of the index finger. Treatment was conservative with a sleeve including a gel cushion which protected the forearm against the edge of the instrument. Function recurred completely within six weeks without ever interrupting instrument practice.

  13. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  14. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  15. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  16. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  17. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  18. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  19. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. Link to an amendment published at 79 FR 34637, June 18, 2014... nickel acrylate complex (PMN P-85-1034) is subject to reporting under this section for the...

  20. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  1. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid...

  2. 21 CFR 173.5 - Acrylate-acrylamide resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Acrylate-acrylamide resins. 173.5 Section 173.5... CONSUMPTION Polymer Substances and Polymer Adjuvants for Food Treatment § 173.5 Acrylate-acrylamide resins. Acrylate-acrylamide resins may be safely used in food under the following prescribed conditions: (a)...

  3. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Acrylamide-acrylic acid resins. 176.110 Section 176... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in...

  4. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in...

  5. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be...

  6. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be...

  7. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in...

  8. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be...

  9. 40 CFR 721.10537 - Acrylate ester (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate ester (generic). 721.10537... Substances § 721.10537 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-01-579) is subject...

  10. 40 CFR 721.10477 - Acrylate ester (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate ester (generic). 721.10477... Substances § 721.10477 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-04-290) is subject...

  11. 40 CFR 721.10477 - Acrylate ester (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate ester (generic). 721.10477... Substances § 721.10477 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-04-290) is subject...

  12. 40 CFR 721.10537 - Acrylate ester (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate ester (generic). 721.10537... Substances § 721.10537 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-01-579) is subject...

  13. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... prescribed for polyethylene in § 177.1520. (1) Specifications—(i) Infrared identification. Ethylene-ethyl acrylate copolymers can be identified by their characteristic infrared spectra. (ii) Quantitative determination of ethyl acrylate content. The ethyl acrylate can be determined by the infrared spectra. Prepare...

  14. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... prescribed for polyethylene in § 177.1520. (1) Specifications—(i) Infrared identification. Ethylene-ethyl acrylate copolymers can be identified by their characteristic infrared spectra. (ii) Quantitative determination of ethyl acrylate content. The ethyl acrylate can be determined by the infrared spectra. Prepare...

  15. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  16. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  17. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  18. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  19. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  20. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  1. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as...

  2. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  3. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  4. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  5. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as...

  6. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as...

  7. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  8. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be...

  9. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in...

  10. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  11. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  12. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as...

  13. 40 CFR 721.10307 - Acrylate resin (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate resin (generic). 721.10307... Substances § 721.10307 Acrylate resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate resin (PMN P-01-343) is subject...

  14. 40 CFR 721.10307 - Acrylate resin (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylate resin (generic). 721.10307... Substances § 721.10307 Acrylate resin (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate resin (PMN P-01-343) is subject...

  15. 21 CFR 173.5 - Acrylate-acrylamide resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Acrylate-acrylamide resins. 173.5 Section 173.5... CONSUMPTION Polymer Substances and Polymer Adjuvants for Food Treatment § 173.5 Acrylate-acrylamide resins. Acrylate-acrylamide resins may be safely used in food under the following prescribed conditions: (a)...

  16. Anterior knee pain

    MedlinePlus

    ... as running, jumping or twisting, skiing, or playing soccer). You have flat feet. Anterior knee pain is ... to the kneecap Runners, jumpers, skiers, bicyclists, and soccer players who exercise often Teenagers and healthy young ...

  17. Acrylic Tanks for Stunning Chemical Demonstrations

    ERIC Educational Resources Information Center

    Mirholm, Alexander; Ellervik, Ulf

    2009-01-01

    We describe the use of acrylic tanks (400 x 450 x 27 mm) for visualization of chemical demonstrations in aqueous solutions. Examples of well-suited demonstrations are oscillating reactions, pH indicators, photochemical reduction of Lauth's violet, and chemoluminiscent reactions. (Contains 1 figure.)

  18. 40 CFR 721.405 - Polyether acrylate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 721.405 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.405 Polyether acrylate. (a) Chemical substance and significant new uses subject to reporting....

  19. 40 CFR 721.405 - Polyether acrylate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 721.405 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.405 Polyether acrylate. (a) Chemical substance and significant new uses subject to reporting....

  20. UV-curable acrylated coating from epoxidized palm oil

    NASA Astrophysics Data System (ADS)

    Rahman, Nurliyana Abd; Badri, Khairiah Haji; Salleh, Nik Ghazali Nik

    2014-09-01

    The properties of coating film prepared from the incorporation of acrylated palm oil (EPOLA) in commercial epoxy acrylate have been studied. A series of different amount of EPOLA was mixed with commercial epoxy acrylate. The blended acrylates passed through UV light to produce a non-tacky film. The conversion of acrylate double bond was monitored by FTIR. The effect of EPOLA concentration onto coated films were investigated by determination of the pendulum hardness and gel content. The higher the amount of EPOLA, the lower the pendulum hardness and the gel content but to a level acceptable for usage in the high-end applications.

  1. Dilemmas in Treatment of Recurrent Recalcitrant Dental Anterior Open Bite.

    PubMed

    Palencar, Adrian J

    2016-01-01

    An anterior open bite is one of the most difficult occlusal abnormalities to treat. Quite often this aberration entails dental component and/or skeletal component. The skeletal open bite will require intrusion of the posterior sextants with the assistance of bite blocks, temporary anchorage devices, high pull headgear, and as a last resort - orthognathic surgery. The orthodontic treatment should be augmented with the orofacial myofunctional therapy. In this article, the author describes 3 different variations of treatment of the dental anterior open bite, first on acrylic models, and then on the actual patients. Consideration should be given to patients with a 'short upper lip," and in this case, surgical correction should be entertained.

  2. FIXED OR REMOVABLE APPLIANCE FOR EARLY ORTHODONTIC TREATMENT OF FUNCTIONAL ANTERIOR CROSSBITE.

    PubMed

    Wiedel, Anna-Paulina

    2015-01-01

    Anterior crossbite with functional shift also called pseudo Class III is a malocclusion in which the incisal edges of one or more maxillary incisors occlude with the incisal edges of the mandibular incisors in centric relationship: the mandible and mandibular incisors are then guided anteriorly in central occlusion resulting in an anterior crossbite. Early correction, at the mixed dentition stage, is recommended, in order to avoid a compromising dentofacial condition which could result in the development of a true Class III malocclusion and temporomandibular symptoms. Various treatment options are available. The method of choice for orthodontic correction of this condition should not only be clinically effective, with long-term stability, but also cost-effective and have high patient acceptance, i.e. minimal perceived pain and discomfort. At the mixed dentition stage, the condition may be treated by fixed (FA) or removable appliance (RA). To date there is insufficient evidence to determine the preferred method. The overall aim of this thesis was therefore to compare and evaluate the use of FA and RA for correcting anterior crossbite with functional shift in the mixed dentition, with special reference to clinical effectiveness, stability, cost-effectiveness and patient perceptions. Evidence-based, randomized controlled trial (RCT) methodology was used, in order to generate a high level of evidence. The thesis is based on the following studies: The material comprised 64 patients, consecutively recruited from the Department of Orthodontics, Faculty of Odontology, Malmö University, Sweden and from one Public Dental Health Service Clinic in Malmö, Skane County Council, Sweden. The patients were no syndrome and no cleft patients. The following inclusion criteria were applied: early to late mixed dentition, anterior crossbite affecting one or more incisors with functional shift, moderate space deficiency in the maxilla, no inherent skeletal Class III discrepancy, ANB

  3. Large Acrylic Spherical Windows In Hyperbaric Underwater Photography

    NASA Astrophysics Data System (ADS)

    Lones, Joe J.; Stachiw, Jerry D.

    1983-10-01

    Both acrylic plastic and glass are common materials for hyperbaric optical windows. Although glass continues to be used occasionally for small windows, virtually all large viewports are made of acrylic. It is easy to uderstand the wide use of acrylic when comparing design properties of this plastic with those of glass, and glass windows are relatively more difficult to fabricate and use. in addition there are published guides for the design and fabrication of acrylic windows to be used in the hyperbaric environment of hydrospace. Although these procedures for fabricating the acrylic windows are somewhat involved, the results are extremely reliable. Acrylic viewports are now fabricated to very large sizes for manned observation or optical quality instrumen tation as illustrated by the numerous acrylic submersible vehicle hulls for hu, an occupancy currently in operation and a 3600 large optical window recently developed for the Walt Disney Circle Vision under-water camera housing.

  4. Anterior skull base oncocytoma.

    PubMed

    López, Fernando; Vivanco, Blanca; Suárez, Carlos; Llorente, José L

    2013-03-01

    Oncocytic neoplasms are tumors composed of oncocytes (ie, epithelial cells with a large cytoplasm that is rich in mitochondria). Most cases are benign and originate from the salivary glands. Although there have been a few reported cases of oncocytomas being found in the sinonasal tract, most if not all cases seem not to involve the anterior skull base. We report a rare case of oncocytoma involving the anterior skull base occurring in a 44-year-old male patient. Preoperative carotid angiography and selective embolization was performed. The patient underwent an expanded endoscopic endonasal anterior craniofacial resection, which allowed complete resection of the tumor, with a low morbidity. The pathological diagnosis was oncocytoma. At 36 months after the initial treatment, the patient is free of disease. Based on our literature search, this may be the first such reported case. A brief review of the available literature examining the known body of knowledge regarding these neoplasms is presented.

  5. Anterior tibial striations.

    PubMed

    Daffner, R H

    1984-09-01

    Radiolucent horizontal striations of the anterior cortex of the tibia were seen in 10 athletes who were evaluated for "shin-splints." There were seven basketball players, two professional dancers, and one hurdler. Each patient's history included vigorous leaping in performance of athletic feats. All the lesions were similar in location and appearance and were accompanied by thickening of the anterior tibial cortex. These striations are considered stress fractures and were not observed in a group of runners who were evaluated for shin-splints.

  6. Congenital anterior urethral diverticulum.

    PubMed

    Singh, Sanjeet Kumar; Ansari, Ms

    2014-09-01

    Congenital anterior urethral diverticulum (CAUD) may be found all along the anterior urethra and may present itself at any age, from infant to adult. Most children with this condition present with difficulty in initiating micturition, dribbling of urine, poor urinary stream, or urinary tract infection. A careful history will reveal that these children never had a good urinary stream since birth, and the telltale sign is a cystic swelling of the penile urethra. In this paper, we present two cases of CAUD that were managed by excision of the diverticulum with primary repair. PMID:26328174

  7. Intercalation of acrylic acid and sodium acrylate into kaolinite and their in situ polymerization

    NASA Astrophysics Data System (ADS)

    Zhang, Bo; Li, Yanfeng; Pan, Xiaobing; Jia, Xin; Wang, Xiaolong

    2007-02-01

    Novel nano-composites of poly (acrylic acid)-kaolinite were prepared, and intercalation and in situ polymerization were used in this process. The nano-composites were obtained by in situ polymerization of acrylic acid (AA) and sodium acrylate (AANa) intercalated into organo-kaolinite, which was obtained by refining and chemically modifying with solution intercalation step in order to increase the basal plane distance of the original clay. The modification was completed by using dimethyl-sulfoxide (DMSO)/methanol and potassium acetate (KAc)/water systems step by step. The materials were characterized with the help of XRD, FT-IR and TEM; the results confirmed that poly(acrylic acid) (PAA) and poly(sodium acrylate) (PAANa) were intercalated into the interlamellar spaces of kaolinite, the resulting copolymer composites (CC0 : copolymer crude kaolinite composite, CC1 : copolymer DMSO kaolinite composite, CC2 : copolymer KAc kaolinite composite) of CC2 exhibited a lamellar nano-composite with a mixed nano-morphology, and partial exfoliation of the intercalating clay platelets should be the main morphology. Finally, the effect of neutralization degree on the intercalation behavior was also investigated.

  8. 'Weightless' acrylic painting by Jack Kroehnke

    NASA Technical Reports Server (NTRS)

    1987-01-01

    'Weightless' acrylic painting by Jack Kroehnke depicts STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) David C. Hilmers participating in extravehicular activity (EVA) simulation in JSC Weightless Environment Training Facility (WETF) Bldg 29. In the payload bay (PLB) mockup, Hilmers, wearing extravehicular mobility unit (EMU), holds onto the mission-peculiar equipment support structure in foreground while SCUBA-equipped diver monitors activity overhead and camera operator records EVA procedures. Copyrighted art work for use by NASA.

  9. ICI/BASF PP for acrylics swap

    SciTech Connect

    Alperowicz, N.

    1993-01-27

    ICI (London) and BASF (Ludwigshafen) have announced their long-awaited polypropylene (PP) for acrylics swap deal. ICI is buying BASF's European acrylic resin business, and the German firm will acquire ICI's European PP operations. The deal is due for completion by mid-1993, subject to regulatory approvals. BASF, hitherto a small-scale PP producer, doubles capacity to 600,000 m.t./year and moves up the European PP league to number three, behind Himont and Shell. BASF, whose process is used in the plants, secures a foothold in the UK PP market, where Shell - planning a merger with Himont - is the only other producer, with 170,000 m.t./year. ICI's purchase involves BASF's Resart GmbH and Critesa SA subsidiaries, located at Mainz, Germany and near Barcelona, Spain, respectively. The business - which will add about [Brit pounds]60 million ($93 million) to ICI Acrylics [Brit pounds]300-million revenues - employs 400 people, who will transfer to ICI.

  10. The edges of graphene.

    PubMed

    Zhang, Xiuyun; Xin, John; Ding, Feng

    2013-04-01

    The edge of two dimensional (2D) graphene, as the surface of a three dimensional (3D) crystal, plays a crucial role in the determination of its physical, electronic and chemical properties and thus has been extensively studied recently. In this review, we summarize the recent advances in the study of graphene edges, including edge formation energy, edge reconstruction, method of graphene edge synthesis and the recent progress on metal-passivated graphene edges and the role of edges in graphene CVD growth. We expect this review to provide a guideline for readers to gain a clear picture of graphene edges from several aspects, especially the catalyst-passivated graphene edges and their role in graphene CVD growth.

  11. Performance comparison of acrylic and thiol-acrylic resins in two-photon polymerization.

    PubMed

    Jiang, Lijia; Xiong, Wei; Zhou, Yushen; Liu, Ying; Huang, Xi; Li, Dawei; Baldacchini, Tommaso; Jiang, Lan; Lu, Yongfeng

    2016-06-13

    Microfabrication by two-photon polymerization is investigated using resins based on thiol-ene chemistry. In particular, resins containing different amounts of a tetrafunctional acrylic monomer and a tetrafunctional thiol molecule are used to create complex microstructures. We observe the enhancement of several characteristics of two-photon polymerization when using thiol-acrylic resins. Specifically, microfabrication is carried out using higher writing velocities and it produces stronger polymeric microstructures. Furthermore, the amount of shrinkage typically observed in the production of three-dimensional microstructures is reduced also. By means of microspectrometry, we confirm that the thiol-acrylate mixture in TPP resins promote monomer conversion inducing a higher degree of cross-linked network formation.

  12. Performance comparison of acrylic and thiol-acrylic resins in two-photon polymerization.

    PubMed

    Jiang, Lijia; Xiong, Wei; Zhou, Yushen; Liu, Ying; Huang, Xi; Li, Dawei; Baldacchini, Tommaso; Jiang, Lan; Lu, Yongfeng

    2016-06-13

    Microfabrication by two-photon polymerization is investigated using resins based on thiol-ene chemistry. In particular, resins containing different amounts of a tetrafunctional acrylic monomer and a tetrafunctional thiol molecule are used to create complex microstructures. We observe the enhancement of several characteristics of two-photon polymerization when using thiol-acrylic resins. Specifically, microfabrication is carried out using higher writing velocities and it produces stronger polymeric microstructures. Furthermore, the amount of shrinkage typically observed in the production of three-dimensional microstructures is reduced also. By means of microspectrometry, we confirm that the thiol-acrylate mixture in TPP resins promote monomer conversion inducing a higher degree of cross-linked network formation. PMID:27410383

  13. Palladium (Ii) Catalyzed Polymerization Of Norbornene And Acrylates

    DOEpatents

    Sen, Ayusman; Kacker, Smita; Hennis, April; Polley, Jennifer D.

    2001-10-09

    Homopolymers or copolymers of acrylates, homopolymers or copolymers of norbornenes, and copolymers of acrylates with norbornenes, may be prepared by contacting acrylate and/or norbornene monomer reactant under polymerization conditions and in the presence of a solvent with a catalyst system consisting essentially of a Pd(II) dimer component having the formula: where L is a monodentate phosphorus or nitrogen ligand, X is an anionic group, and R is an alkyl or aryl group.

  14. Palladium (II) catalyized polymerization of norbornene and acrylates

    DOEpatents

    Sen, Ayusman; Kacker, Smita; Hennis, April; Polley, Jennifer D.

    2000-08-29

    Homopolymers or copolymers of acrylates, homopolymers or copolymers of norbornenes, and copolymers of acrylates with norbornenes, may be prepared by contacting acrylate and/or norbornene monomer reactant under polymerization conditions and in the presence of a solvent with a catalyst system consisting essentially of a Pd(II) dimer component having the formula: [(L)Pd(R)(X)].sub.2, where L is a monodentate phosphorus or nitrogen ligand, X is an anionic group, and R is an alkyl or aryl group.

  15. Pulse radiolysis of aqueous solutions of ethyl acrylate and hydroxy ethyl acrylate

    NASA Astrophysics Data System (ADS)

    Safrany, A.; Biro, A.; Wojnarovits, L.

    1993-10-01

    Ethyl- and hydroxy ethyl acrylate show high reactivities with hydrated electron and hydroxyl radical intermediates of water radiolysis. The electron adduct reversibly protonate with pK values of 5.7 and 7.3. The adducts may take part in irreversible protonation at the β carbon atom forming α-carboxyl alkyl radicals. Same type of radical forms in reaction of acrylates with OH: at low concentration the adduct mainly disappear in self termination reactions. Above 5 mmol dm -1 the signals showed the startup of oligomerization.

  16. Severe Onychodystrophy due to Allergic Contact Dermatitis from Acrylic Nails

    PubMed Central

    Mattos Simoes Mendonca, Marcela; LaSenna, Charlotte; Tosti, Antonella

    2015-01-01

    Acrylic nails, including sculptured nails and the new ultraviolet-curable gel polish lacquers, have been associated with allergic contact dermatitis (ACD). We report 2 cases of ACD to acrylic nails with severe onychodystrophy and psoriasiform changes including onycholysis and subungual hyperkeratosis. In both cases, the patients did not realize the association between the use of acrylate-based manicures and nail changes. One patient had been previously misdiagnosed and treated unsuccessfully for nail psoriasis. The informed clinician should elicit a history of acrylic manicure in patients with these nail changes, especially in cases of suspected nail psoriasis refractory to treatment. Patch testing is a useful tool in confirming diagnosis. PMID:27170940

  17. Severe Onychodystrophy due to Allergic Contact Dermatitis from Acrylic Nails.

    PubMed

    Mattos Simoes Mendonca, Marcela; LaSenna, Charlotte; Tosti, Antonella

    2015-09-01

    Acrylic nails, including sculptured nails and the new ultraviolet-curable gel polish lacquers, have been associated with allergic contact dermatitis (ACD). We report 2 cases of ACD to acrylic nails with severe onychodystrophy and psoriasiform changes including onycholysis and subungual hyperkeratosis. In both cases, the patients did not realize the association between the use of acrylate-based manicures and nail changes. One patient had been previously misdiagnosed and treated unsuccessfully for nail psoriasis. The informed clinician should elicit a history of acrylic manicure in patients with these nail changes, especially in cases of suspected nail psoriasis refractory to treatment. Patch testing is a useful tool in confirming diagnosis. PMID:27170940

  18. Complete denture technique using natural anterior teeth.

    PubMed

    Kafandaris, N M; Theodorou, T P

    1975-05-01

    A technique has been described which permits the use of desirable natural anterior teeth in complete dentures (Fig. 3). The main characteristic of this technique is the use of cast copings with dowels to which the natural teeth are attached. The cast copings securely fit the natural teeth to the base of the denture (Fig, 4). The use of NATURAL teeth in a denture may encourage discoloration of fracture. Discoloration of the natural teeth may be prevented by the immediate removal of the pulp tissue, the attentive cleaning of the pulp chamber with normal saline, and the storage of the teeth in an atmosphere of 100 per cent humidity. Adequate vertical and horizontal overlaps insure stability of the denture and suitable protection of the natural teeth from cracknig or curshing during function of the denture. If accidental fracture or discoloration of a natural tooth should occur, ti may be replaced by an acrylic resin tooth duplicated from the natural tooth or by an artifical tooth of proper size and color. PMID:1092840

  19. Acrylic Finger Prosthesis: A Case Report

    PubMed Central

    Bandela, Vinod; M, Bharathi; S V, Giridhar Reddy

    2014-01-01

    Hands basic function is to grasp, hold and manipulate items. Hand gesture is perhaps the most blatant example of non-verbal communication. Finger and partial finger amputations are most frequently encountered forms of partial hand loss. Common causes are traumatic injuries, congenital absence or malformations present great clinical challenges. In addition to immediate loss of grasp strength, finger absence may cause marked psychological trauma. Individuals who desire finger replacement usually have high expectation for the appearance of prosthesis. This clinical report portrays simple method to retain acrylic finger prosthesis. PMID:25302271

  20. 40 CFR 721.10500 - Acrylated mixed metal oxides (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylated mixed metal oxides (generic... Specific Chemical Substances § 721.10500 Acrylated mixed metal oxides (generic). (a) Chemical substance and... mixed metal oxides (PMN P-06-341) is subject to reporting under this section for the significant...

  1. 40 CFR 721.10500 - Acrylated mixed metal oxides (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylated mixed metal oxides (generic... Specific Chemical Substances § 721.10500 Acrylated mixed metal oxides (generic). (a) Chemical substance and... mixed metal oxides (PMN P-06-341) is subject to reporting under this section for the significant...

  2. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  3. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  4. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  5. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  6. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  7. The Acrylation of Glycerol: a Precursor to Functionalized Lipids

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Didecanoylacryloylglycerol was synthesized from decanoic and acrylic acids and glycerol using K2O as catalyst. This reaction was carried out in hexane in a closed stainless steel reactor at 200°C for 5h. The reactants were added in a 1:3:4 glycerol:decanoic acid:acrylic acid molar ratio. The resu...

  8. 40 CFR 721.10307 - Acrylate resin (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate resin (generic). 721.10307 Section 721.10307 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10307 Acrylate resin...

  9. 40 CFR 721.330 - Aromatic acrylate (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.330 Aromatic acrylate (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an aromatic acrylate (PMN P-01-420)...

  10. 40 CFR 721.330 - Aromatic acrylate (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.330 Aromatic acrylate (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an aromatic acrylate (PMN P-01-420)...

  11. Esthetic rehabilitation of anterior discolored teeth with lithium disilicate all-ceramic restorations.

    PubMed

    Prevedello, Gustavo Costa; Vieira, Marcelo; Furuse, Adilson Yoshio; Correr, Gisele Maria; Gonzaga, Carla Castiglia

    2012-01-01

    The esthetic treatment of darkened anterior teeth represents a great challenge to dentists, because dental materials ideally should match the natural teeth. The optical behavior of the final restoration is determined by the color of the underlying tooth structure, the color of the luting agent, and the thickness and opacity of the ceramic material used. This article reports a case in which veneers and full crowns made of heat-pressed, lithium disilicate glass-ceramic were used for the esthetic rehabilitation of anterior discolored teeth. The patient was referred for treatment with defective anterior composite resin restorations, provisional acrylic resin crowns, darkening of the gingival margins, and uneven gingival contours. The multidisciplinary treatment plan included dental bleaching, periodontal plastic surgery to create gingival symmetry, and indirect all-ceramic restorations using high-opacity lithium disilicate glass-ceramic ingots. The treatment was successful and an excellent esthetic result was achieved.

  12. Capsulorhexis phimosis with anterior flexing of an accommodating IOL: case report and histopathological analyses.

    PubMed

    Epstein, Rachel H; Liu, Erica T; Werner, Liliana; Kohnen, Thomas; Kaproth, Oliver K; Mamalis, Nick

    2014-01-01

    We describe the case of a patient who had cataract surgery with implantation of an accommodating hydrophilic acrylic intraocular lens (IOL) that exhibited capsulorhexis phimosis and in-the-bag IOL luxation leading to explantation of the IOL-capsular bag complex 10 years after implantation. Constriction of the capsular bag secondary to fibrosis caused significant anterior flexing of the haptic elements of the IOL. Histopathological analysis revealed dense anterior subcapsular fibrosis and fibrous metaplasia of the anterior lens epithelial cells. No signs suggestive of pseudoexfoliation were found. This case raises concerns related to the continuously evolving indications for implantation of accommodating and other highly flexible IOLs (eg, microincision IOLs), particularly in patients with no clear predisposition to zonular weakness and, accordingly, excessive capsular bag contraction. PMID:24355727

  13. Calcification of a hydrophilic acrylic intraocular lens: case report with laboratory analysis.

    PubMed

    Bodnar, Z M; Rozot, P; Leishman, L; Ollerton, A; Michelson, J; Plasse-Fauque, S; Werner, L

    2013-09-01

    We analyzed a single-piece plate-type hydrophilic acrylic posterior chamber intraocular lens (IOL) that was explanted due to a progressive loss of vision, which occurred 6 years after uncomplicated phacoemulsification. Gross and light microscopy, as well as anterior segment optical coherence tomography (OCT) revealed granular deposits below the IOL surface. Light scattering, as measured with Scheimpflug photography and densitometry analyses was found to be increased; spectrophotometry demonstrated a decrease in the light transmittance of the explanted lens. The granular deposits within the IOL material were found to be composed of calcium by histochemical methods (alizarin red and Von Kossa stains). To our knowledge this is the only report of calcification of this IOL design. PMID:23688611

  14. Tibialis Anterior Tendon Transfer.

    PubMed

    Mulhern, Jennifer L; Protzman, Nicole M; Brigido, Stephen A

    2016-01-01

    Tendon transfer procedures are used commonly for the correction of soft tissue imbalances and instabilities. The complete transfer and the split transfer of the tibialis anterior tendon are well-accepted methods for the treatment of idiopathic equinovarus deformity in children and adults. Throughout the literature, complete and split transfer have been shown to yield significant improvements in ankle and foot range of motion and muscle function. At present, there is insufficient evidence to recommend one procedure over the other, although the split procedure has been advocated for consistently achieving inversion to eversion muscle balance without overcorrection.

  15. Anterior endoscopic correction of scoliosis.

    PubMed

    Picetti, George D; Ertl, Janos P; Bueff, H Ulrich

    2002-04-01

    Our technique of anterior endoscopic scoliosis correction demonstrates the ability to perform an anterior approach through a minimally invasive technique with minimal disruption of the local biology. The initial results appear to equal curve correction and fusion rates to those of a formal open anterior approach. Additional benefits are: 1) shortened operative time, 2) lower blood loss, 3) shortened rehabilitation time, 4) less pain, and 5) shortened hospital stays. Endoscopic technique shows great promise in the management of scoliosis curves; however, this is a technically demanding procedure that requires cross-training in endoscopic discectomy and scoliosis management as well as familiarity with the anterior approach anatomy. PMID:12389288

  16. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ethylene-methyl acrylate copolymer resins. 177...-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used as... prescribed conditions: (a) For the purpose of this section, the ethylene-methyl acrylate copolymer...

  17. Electrochemical characterization of aminated acrylic conducting polymer

    SciTech Connect

    Rashid, Norma Mohammad; Heng, Lee Yook; Ling, Tan Ling

    2015-09-25

    New attempt has been made to synthesize aminated acrylic conducting polymer (AACP) using precursor of phenylvinylsulfoxide (PVS). The process was conducted via the integration of microemulsion and photopolymerization techniques. It has been utilized for covalent immobilization of amino groups by the adding of N-achryiloxisuccinimide (NAS). Thermal eliminating of benzene sulfenic acids from PVS has been done at 250 °C to form electroactive polyacetylene (PA) segment. Characterization of AACP has been conducted using fourier transform infrared (FTIR), scanning electron microscopy (SEM) and linear sweep cyclic voltammetry (CV). A range of 0.3-1.25μm particle size obtained from SEM characterization. A quasi-reversible system performed as shown in electrochemical study.

  18. Electrochemical characterization of aminated acrylic conducting polymer

    NASA Astrophysics Data System (ADS)

    Rashid, Norma Mohammad; Heng, Lee Yook; Ling, Tan Ling

    2015-09-01

    New attempt has been made to synthesize aminated acrylic conducting polymer (AACP) using precursor of phenylvinylsulfoxide (PVS). The process was conducted via the integration of microemulsion and photopolymerization techniques. It has been utilized for covalent immobilization of amino groups by the adding of N-achryiloxisuccinimide (NAS). Thermal eliminating of benzene sulfenic acids from PVS has been done at 250 °C to form electroactive polyacetylene (PA) segment. Characterization of AACP has been conducted using fourier transform infrared (FTIR), scanning electron microscopy (SEM) and linear sweep cyclic voltammetry (CV). A range of 0.3-1.25μm particle size obtained from SEM characterization. A quasi-reversible system performed as shown in electrochemical study.

  19. Flexible, stretchable electroadhesives based on acrylic elastomers

    NASA Astrophysics Data System (ADS)

    Duduta, Mihai; Wood, Robert J.; Clarke, David R.

    2016-04-01

    Controllable adhesion is a requirement for a wide variety of applications including robotic manipulation, as well as locomotion including walking, crawling and perching. Electroadhesives have several advantages such as reversibility, low power consumption and controllability based on applied voltage. Most demonstrations of electroadhesive devices rely on fairly rigid materials, which cannot be stretched reversibly, as needed in some applications. We have developed a fast and reliable method for building soft, stretchable electroadhesive pads based on acrylic elastomers and electrodes made of carbon nanotubes. The devices produced were tested pre-deformation and in a stretched configuration. The adhesive force was determined to be in the 0.1 - 3.0 N/cm2 range, depending on the adhering surface. The electroadhesive devices were integrated with pre-stretched dielectric elastomer actuators to create a device in which the adhesion force could be tuned by changes in either the applied voltage or total area.

  20. Bioengineered anterior cruciate ligament

    NASA Technical Reports Server (NTRS)

    Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor); Martin, Ivan (Inventor)

    2001-01-01

    The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the

  1. Modification of hydrophobic acrylic intraocular lens with poly(ethylene glycol) by atmospheric pressure glow discharge: A facile approach

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Wang, Yao; Huang, Xiao-Dan; Xu, Zhi-Kang; Yao, Ke

    2010-10-01

    To improve the anterior surface biocompatibility of hydrophobic acrylic intraocular lens (IOL) in a convenient and continuous way, poly(ethylene glycol)s (PEGs) were immobilized by atmospheric pressure glow discharge (APGD) treatment using argon as the discharge gas. The hydrophilicity and chemical changes on the IOL surface were characterized by static water contact angle and X-ray photoelectron spectroscopy to confirm the covalent binding of PEG. The morphology of the IOL surface was observed under field emission scanning electron microscopy and atomic force microscopy. The surface biocompatibility was evaluated by adhesion experiments with platelets, macrophages, and lens epithelial cells (LECs) in vitro. The results revealed that the anterior surface of the PEG-grafted IOL displayed significantly and permanently improved hydrophilicity. Cell repellency was observed, especially in the PEG-modified IOL group, which resisted the attachment of platelets, macrophages and LECs. Moreover, the spread and growth of cells were suppressed, which may be attributed to the steric stabilization force and chain mobility effect of the modified PEG. All of these results indicated that hydrophobic acrylic IOLs can be hydrophilic modified by PEG through APGD treatment in a convenient and continuous manner which will provide advantages for further industrial applications.

  2. Custom cranioplasty using stereolithography and acrylic.

    PubMed

    D'Urso, P S; Earwaker, W J; Barker, T M; Redmond, M J; Thompson, R G; Effeney, D J; Tomlinson, F H

    2000-04-01

    Numerous methods of cranioplasty have been described. Customization and prefabrication have been reported to reduce operating time and improve cosmesis. An original technique for the manufacture of customized cranioplastic implants has been developed and tested in 30 patients.Thirty patients requiring cranioplasties were selected. Data acquired from computed tomography (CT) were used to manufacture exact plastic replicas (biomodels) of craniotomy defects and master cranioplastic implants using the rapid prototyping technology of stereolithography (SL). The three-dimensional (3D) imaging techniques of mirroring and interpolation were used to extrapolate on existing anatomy to design the master implants. The master implants were hand finished to fit the defect in the corresponding cranial biomodel exactly and were then used to create a cavity mould. The mould was used to cast thermally polymerised custom acrylic implants. The surgeons reported that the customized implants reduced operating time, afforded excellent cosmesis and were cost effective. The patients reported that the opportunity to see the biomodel and implant preoperatively improved their understanding of the procedure. Two complications were noted, one infection and one implant required significant trimming. The simultaneous manufacture of the master implant (male) and biomodel (female) components from SL allowed custom accurate implants to be manufactured. Disadvantages identified were the time required for computer manipulations of the CT data (up to 2 h), difficulty in assessing the accuracy of the computer generated master as a 3D rendering, the potential for SL parts to warp, manufacturing time (minimum 2 days) and the cost of approximately $1300 US per case ($1000 for the SL biomodel and $300 for the acrylic casting). PMID:10738323

  3. Poly(amide-graft-acrylate) interfacial compounds

    NASA Astrophysics Data System (ADS)

    Zamora, Michael Perez

    Graft copolymers with segments of dissimilar chemistries have been shown to be useful in a variety of applications as surfactants, compatibilizers, impact modifiers, and surface modifiers. The most common route to well defined graft copolymers is through the use of macromonomers, polymers containing a reactive functionality and thus capable of further polymerization. However, the majority of the studies thus far have focused on the synthesis of macromonomers capable of reacting with vinyl monomers to form graft copolymers. This study focused on the synthesis of macromonomers capable of participating in condensation polymerizations. A chain transfer functionalization method was utilized. Cysteine was evaluated as a chain transfer agent for the synthesis of amino acid functionalized poly(acrylate) and poly(methacrylate) macromonomers. Low molar mass, functionalized macromonomers were produced. These macromonomers were proven to be capable of reacting with amide precursors to form poly(amide-g-acrylate) graft copolymers. Macromonomers and graft copolymers were characterized by gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance (NMR) spectroscopy, elemental analysis (EA), inductively coupled plasma (ICP), and differential scanning calorimetry (DSC). The second part of this research involved poly(dimethacrylate) dental restorative materials. Volumetric shrinkage during the cure of these resins results in a poor interface between the resin and the remaining tooth structure, limiting the lifetime of these materials. Cyclic anhydrides were incorporated into common monomer compositions used in dental applications. Volume expansion from the ring opening hydrolysis of these anhydrides was shown to be feasible. The modified dental resins were characterized by swelling, extraction and ultraviolet spectroscopy (UV), and density measurements. Linear poLymers designed to model the crosslinked dental resins were

  4. The Edge, Fall 1999.

    ERIC Educational Resources Information Center

    Edge, 1999

    1999-01-01

    "The Edge" is a Canadian publication for youth. The mandate of the Edge is to support and celebrate all career journeys embraced by youth. This issue contains career profile articles covering three jobs: crane operator, indoor climbing instructor, and product certification tester. Career trends and the state of today's workplace are also…

  5. Supersonic Leading Edge Receptivity

    NASA Technical Reports Server (NTRS)

    Maslov, Anatoly A.

    1998-01-01

    This paper describes experimental studies of leading edge boundary layer receptivity for imposed stream disturbances. Studies were conducted in the supersonic T-325 facility at ITAM and include data for both sharp and blunt leading edges. The data are in agreement with existing theory and should provide guidance for the development of more complete theories and numerical computations of this phenomena.

  6. Conversion of Lignocellulosic Biomass to Ethanol and Butyl Acrylate

    SciTech Connect

    Binder, Thomas; Erpelding, Michael; Schmid, Josef; Chin, Andrew; Sammons, Rhea; Rockafellow, Erin

    2015-04-10

    Conversion of Lignocellulosic Biomass to Ethanol and Butyl Acrylate. The purpose of Archer Daniels Midlands Integrated Biorefinery (IBR) was to demonstrate a modified acetosolv process on corn stover. It would show the fractionation of crop residue to distinct fractions of cellulose, hemicellulose, and lignin. The cellulose and hemicellulose fractions would be further converted to ethanol as the primary product and a fraction of the sugars would be catalytically converted to acrylic acid, with butyl acrylate the final product. These primary steps have been demonstrated.

  7. Investigation of Acrylic Acid at High Pressure Using Neutron Diffraction

    PubMed Central

    2014-01-01

    This article details the exploration of perdeuterated acrylic acid at high pressure using neutron diffraction. The structural changes that occur in acrylic acid-d4 are followed via diffraction and rationalized using the Pixel method. Acrylic acid undergoes a reconstructive phase transition to a new phase at ∼0.8 GPa and remains molecular to 7.2 GPa before polymerizing on decompression to ambient pressure. The resulting product is analyzed via Raman and FT-IR spectroscopy and differential scanning calorimetry and found to possess a different molecular structure compared with polymers produced via traditional routes. PMID:24650085

  8. Methods for the synthesis of deuterated acrylate salts

    SciTech Connect

    Yang, Jun; Bonnesen, Peter V.; Hong, Kunlun

    2014-09-09

    A method for synthesizing a deuterated acrylate of the Formula (1), the method comprising: (i) deuterating a propiolate compound of Formula (2) to a methyne-deuterated propiolate compound of Formula (3) in the presence of a base and D.sub.2O: and (ii) reductively deuterating the methyne-deuterated propiolate compound of Formula (3) in a reaction solvent in the presence of deuterium gas and a palladium-containing catalyst to afford the deuterated acrylate of the Formula (1). The resulting deuterated acrylate compounds, derivatives thereof, and polymers derived therefrom are also described.

  9. A simple solubility tests for the discrimination of acrylic and modacrylic fibers.

    PubMed

    Suga, Keisuke; Narita, Yuji; Suzuki, Shinichi

    2014-05-01

    In a crime scene investigation, single fibers play an important role as significant trace physical evidence. Acrylic fibers are frequently encountered in forensic analysis. Currently, acrylic and modacrylic are not discriminated clearly in Japan. Only results of FT-IR, some of acrylics were difficult to separate clearly to acrylic and modacrylic fibers. Solubility test is primitive but convenient useful method, and Japan Industrial Standards (JIS) recommends FT-IR and solubility test to distinguish acrylic and modacrylic fibers. But recommended JIS dissolving test using 100% N,N-dimethylformamide (DMF) as a solvent, some acrylics could not be discriminated. In this report, we used DMF and ethanol (90:10, v/v) solvent. The JIS method could not discriminate 6 acrylics in 60 acrylics; hence, DMF and ethanol (90:10, v/v) solvent discriminated 59 of the 60 fibers (43 acrylic and 16 modacrylic fibers) clearly, but only one modacrylic fiber incorrectly identified as acrylic.

  10. [Determination of 9 residual acrylic monomers in acrylic resins by gas chromatography-mass spectrometry coupled with microwave assisted extraction].

    PubMed

    Lai, Ying; Lin, Rui; Cai, Luxin; Ge, Xiuxiu; Huang, Changchun

    2012-01-01

    A reliable gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of 9 residual acrylic monomers (methyl acrylate, ethyl acrylate, methyl methacrylate, ethyl methacrylate, n-butyl acrylate, butyl methacrylate, styrene, acrylic acid and methacrylic acid) in acrylic resins. Solid resin was precipitated with methanol after microwave assisted extraction with ethyl acetate for 30 min, and liquid resin was diluted with methanol directly. The nine acrylic monomers got a good separation within 20 min on a DB-WAX column. The limits of quantification (LOQs, S/N = 10) of the method were in the range of 1-10 mg/kg for liquid resin and 3-50 mg/kg for solid resin. The calibration curves were linear within 1-500 mg/L range with correlation coefficients above 0. 995. The recoveries ranged from 84.4% to 108.6% at five spiked levels. The sensitivity, recovery and selectivity of the method can fully meet the requirements of practical work.

  11. [Anterior cervical hypertrichosis: case report].

    PubMed

    Orozco-Gutiérrez, Mario H; Sánchez-Corona, José; García-Ortiz, José E; Castañeda-Cisneros, Gema; Dávalos-Rodríguez, Nory O; Corona-Rivera, Jorge R; García-Cruz, Diana

    2016-10-01

    The non-syndromic anterior cervical hypertrichosis (OMIM N° 600457) is a genetic disorder characterized by a patch of hair at the level of the laryngeal prominence. We present a 12-year-old boy with anterior cervical hypertrichosis and mild generalized hypertrichosis. He has no neurological, ophthalmological or skeletal anomalies. The clinical follow up is 10 years.

  12. [Anterior cervical hypertrichosis: case report].

    PubMed

    Orozco-Gutiérrez, Mario H; Sánchez-Corona, José; García-Ortiz, José E; Castañeda-Cisneros, Gema; Dávalos-Rodríguez, Nory O; Corona-Rivera, Jorge R; García-Cruz, Diana

    2016-10-01

    The non-syndromic anterior cervical hypertrichosis (OMIM N° 600457) is a genetic disorder characterized by a patch of hair at the level of the laryngeal prominence. We present a 12-year-old boy with anterior cervical hypertrichosis and mild generalized hypertrichosis. He has no neurological, ophthalmological or skeletal anomalies. The clinical follow up is 10 years. PMID:27606653

  13. Adjacent Segment Pathology after Anterior Cervical Fusion.

    PubMed

    Chung, Jae Yoon; Park, Jong-Beom; Seo, Hyoung-Yeon; Kim, Sung Kyu

    2016-06-01

    Anterior cervical fusion has become a standard of care for numerous pathologic conditions of the cervical spine. However, subsequent development of clinically significant disc disease at levels adjacent to fused discs is a serious long-term complication of this procedure. As more patients live longer after surgery, it is foreseeable that adjacent segment pathology (ASP) will develop in increasing numbers of patients. Also, ASP has been studied more intensively with the recent popularity of motion preservation technologies like total disc arthroplasty. The true nature and scope of ASP remains poorly understood. The etiology of ASP is most likely multifactorial. Various factors including altered biomechanical stresses, surgical disruption of soft tissue and the natural history of cervical disc disease contribute to the development of ASP. General factors associated with disc degeneration including gender, age, smoking and sports may play a role in the development of ASP. Postoperative sagittal alignment and type of surgery are also considered potential causes of ASP. Therefore, a spine surgeon must be particularly careful to avoid unnecessary disruption of the musculoligamentous structures, reduced risk of direct injury to the disc during dissection and maintain a safe margin between the plate edge and adjacent vertebrae during anterior cervical fusion.

  14. Adjacent Segment Pathology after Anterior Cervical Fusion

    PubMed Central

    Chung, Jae Yoon; Park, Jong-Beom; Seo, Hyoung-Yeon

    2016-01-01

    Anterior cervical fusion has become a standard of care for numerous pathologic conditions of the cervical spine. However, subsequent development of clinically significant disc disease at levels adjacent to fused discs is a serious long-term complication of this procedure. As more patients live longer after surgery, it is foreseeable that adjacent segment pathology (ASP) will develop in increasing numbers of patients. Also, ASP has been studied more intensively with the recent popularity of motion preservation technologies like total disc arthroplasty. The true nature and scope of ASP remains poorly understood. The etiology of ASP is most likely multifactorial. Various factors including altered biomechanical stresses, surgical disruption of soft tissue and the natural history of cervical disc disease contribute to the development of ASP. General factors associated with disc degeneration including gender, age, smoking and sports may play a role in the development of ASP. Postoperative sagittal alignment and type of surgery are also considered potential causes of ASP. Therefore, a spine surgeon must be particularly careful to avoid unnecessary disruption of the musculoligamentous structures, reduced risk of direct injury to the disc during dissection and maintain a safe margin between the plate edge and adjacent vertebrae during anterior cervical fusion. PMID:27340541

  15. [Treatment of acrylate wastewater by electrocatalytic reduction process].

    PubMed

    Yu, Li-Na; Song, Yu-Dong; Zhou, Yue-Xi; Zhu, Shu-Quan; Zheng, Sheng-Zhi; Ll, Si-Min

    2011-10-01

    High-concentration acrylate wastewater was treated by an electrocatalytic reduction process. The effects of the cation exchange membrane (CEM) and cathode materials on acrylate reduction were investigated. It indicated that the acrylate could be reduced to propionate acid efficiently by the electrocatalytic reduction process. The addition of CEM to separator with the cathode and anode could significantly improve current efficiency. The cathode materials had significant effect on the reduction of acrylate. The current efficiency by Pd/Nickel foam, was greater than 90%, while those by nickel foam, the carbon fibers and the stainless steel decreased successively. Toxicity of the wastewater decreased considerably and methane production rate in the biochemical methane potential (BMP) test increased greatly after the electrocatalytic reduction process.

  16. Use of acrylic sheet molds for elastomeric products

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Koerner, A. E.; Messineo, S. M.

    1970-01-01

    Molds constructed of acrylic sheet are more easily machined than metal, are transparent to ensure complete filling during injection, and have smooth surfaces free of contamination. Technique eliminates flashing on molded parts and mold release agents.

  17. Performance behavior of modified cellulosic fabrics using polyurethane acrylate copolymer.

    PubMed

    Zuber, Mohammad; Shah, Sayyed Asim Ali; Jamil, Tahir; Asghar, Muhammad Irfan

    2014-06-01

    The surface of the cellulosic fabrics was modified using self-prepared emulsions of polyurethane acrylate copolymers (PUACs). PUACs were prepared by varying the molecular weight of polycaprolactone diol (PCL). The PCL was reacted with isophorone diisocyanate (IPDI) and chain was extended with 2-hydroxy ethyl acrylate (HEA) to form vinyl terminated polyurethane (VTPU) preploymer. The VTPU was further co-polymerized through free radical polymerization with butyl acrylate in different proportions. The FT-IR spectra of monomers, prepolymers and copolymers assured the formation of proposed PUACs structure. The various concentrations of prepared PUACs were applied onto the different fabric samples using dip-padding techniques. The results revealed that the application of polyurethane butyl acrylate copolymer showed a pronounced effect on the tear strength and pilling resistance of the treated fabrics.

  18. Emulsion Polymerization of Butyl Acrylate: Spin Trapping and EPR Study

    NASA Technical Reports Server (NTRS)

    Kim, S.; Westmoreland, D.

    1994-01-01

    The propagating radical in the emulsion polymerization reaction of butyl acrylate was detected by Electron Paramagnetic Resonance spectroscopy using two spin trapping agents, 2-methyl-2nitrosopropane and alpha -N-tert-butylnitrone.

  19. PERMEATION OF MULTIFUNCTIONAL ACRYLATES THROUGH SELECTED PROTECTIVE GLOVE MATERIALS

    EPA Science Inventory

    In support of the Premanufacture Notification (PMN) program of the Environmental Protection Agency's Office of Toxic Substances, the resistance of three glove materials to permeation by multifunctional acrylate compounds was evaluated through a program for the Office of Research ...

  20. Myringoplasty for anterior and subtotal perforations using KTP-532 laser.

    PubMed

    Gerlinger, Imre; Ráth, Gábor; Szanyi, István; Pytel, József

    2006-09-01

    A retrospective study was performed on patients who underwent myringoplasty for either anterior or subtotal perforations over an 8-year period (from 1994 till 2004). We used the KTP-laser assisted anterior anchoring technique combining with anterior "pull-back" method. Patients' ages ranged from 6-62 years (median 36.5). The mean follow-up period was 2.8 years (minimum 6 months). The audiological results were analysed with the "Pytel software", which was developed in our department. As for the procedure, the drum remnant was freed from the malleus handle with the use of the laser and elevated out of it's sulcus anterior-superiorly. Large fascia graft was fashioned with a split of 4-5 mm in the middle of one edge. The graft was placed using the underlay technique medial to the handle of the malleus. A pull-back tunnel was created at the border of the anterior quadrants to further facilitate the survival of the graft. In this series the graft taking rate was 100%. Reperforation due to an undersized fascia was observed in one case. Post-operative audiological results indicated no bone conduction threshold elevation in any frequencies. Using the laser, cochlear trauma can be prevented, double fixation of the drum prevents lateralisation and blunting. Wide canalplasty makes both the approach and the follow-up very easy. Thorough soft tissue and bone work is advantageous from the fascia taking rate point of view.

  1. Features extraction in anterior and posterior cruciate ligaments analysis.

    PubMed

    Zarychta, P

    2015-12-01

    The main aim of this research is finding the feature vectors of the anterior and posterior cruciate ligaments (ACL and PCL). These feature vectors have to clearly define the ligaments structure and make it easier to diagnose them. Extraction of feature vectors is obtained by analysis of both anterior and posterior cruciate ligaments. This procedure is performed after the extraction process of both ligaments. In the first stage in order to reduce the area of analysis a region of interest including cruciate ligaments (CL) is outlined in order to reduce the area of analysis. In this case, the fuzzy C-means algorithm with median modification helping to reduce blurred edges has been implemented. After finding the region of interest (ROI), the fuzzy connectedness procedure is performed. This procedure permits to extract the anterior and posterior cruciate ligament structures. In the last stage, on the basis of the extracted anterior and posterior cruciate ligament structures, 3-dimensional models of the anterior and posterior cruciate ligament are built and the feature vectors created. This methodology has been implemented in MATLAB and tested on clinical T1-weighted magnetic resonance imaging (MRI) slices of the knee joint. The 3D display is based on the Visualization Toolkit (VTK).

  2. Stabilizing effects of estertins mercaptide (methyl acrylate) for PVC degradation

    NASA Astrophysics Data System (ADS)

    Zhang, S. H.; Liu, T. M.; Li, J. L.; Wang, C. R.; Li, C.; Wang, Z. Q.

    2016-07-01

    The thermal and UV light (ultraviolet light) stability of PVC films with estertins mercaptide (methyl acrylate), methyltins mercaptide and the compound consisted of estertins mercaptide (methyl acrylate) and hydrotalcite (2:2.5) were investigated by ageing in a circulation oven at 190 °C and irradiating with 72W UV light for 96h, respectively, and then the yellowness and transmission rate were tested by Color Quest XE. Hydrotalcite was proved to have good synergies with estertins mercaptide (methyl acrylate) on improving the thermal stability and UV light stability. The retarding effects of the heat stabilizers to PVC degradation were tested by TGA from 50°C to 600°C. The results show that temperature of HCl evolution from PVC film was improved obviously by compounding with estertins mercaptide(methyl acrylate) and hydrotalcite and estertins mercaptide(methyl acrylate) was found to have a better long term stability. Sn4+ consistence of water and seawater in which films before and after UV light irradiation were soaked for 60 days was analyzed by ICP; the results indicate that the Sn4+ consistence from the films with estertins mercaptide(methyl acrylate) as thermal stabilizer was lower than that from the film with methyltins mercaptide. The crosslink moderately by UV irradiation for PVC films can hold back the dissolution of organotin heat stabilizers from PVC products into water and seawater.

  3. The digital step edge

    NASA Technical Reports Server (NTRS)

    Haralick, R. M.

    1982-01-01

    The facet model was used to accomplish step edge detection. The essence of the facet model is that any analysis made on the basis of the pixel values in some neighborhood has its final authoritative interpretation relative to the underlying grey tone intensity surface of which the neighborhood pixel values are observed noisy samples. Pixels which are part of regions have simple grey tone intensity surfaces over their areas. Pixels which have an edge in them have complex grey tone intensity surfaces over their areas. Specially, an edge moves through a pixel only if there is some point in the pixel's area having a zero crossing of the second directional derivative taken in the direction of a non-zero gradient at the pixel's center. To determine whether or not a pixel should be marked as a step edge pixel, its underlying grey tone intensity surface was estimated on the basis of the pixels in its neighborhood.

  4. Industrially relevant epoxy-acrylate hybrid resin photopolymerizations

    NASA Astrophysics Data System (ADS)

    Ajiboye, Gbenga I.

    Photopolymerization of epoxy-acrylate hybrid resins takes advantages of inherent properties present in the free-radical and cationic reactions to reduce oxygen inhibition problems that plague free-radical reactions. Similarly, the combined reaction mechanisms reduce moisture sensitivity of the cationic reactions. Despite the advantages of epoxy-acrylate hybrid resins, problems persist that need to be addressed. For example, low conversion and polymerization rate of the epoxides are a problem, because the fast acrylate conversion prevents the epoxide from reaching high conversion. Controlling phase separation is challenging, since two moieties with different properties are reacting. The physical properties of the polymer will be impacted by the availability of different moieties. High shrinkage stress results from the acrylate moiety, causing buckling and cracking in film and coating applications. The overall goal of this study is to use the fundamental knowledge of epoxy-acrylate hybrid resins to formulate industrially viable polymers. In order to achieve this goal, the study focuses on the following objectives: (I) determine the apparent activation energy of the hybrid monomer METHB, (II) increase epoxide conversion and polymerization rate of hybrid formulations, and (III) control physical properties in epoxy-acrylate hybrid resins. In order to increase the epoxide conversion and rate of polymerization, the sensitivity of epoxides to alcohol is used to facilitate the activated monomer (AM) mechanism and induce a covalent bond between the epoxide and acrylate polymers through the hydroxyl group. It is hypothesized that if the AM mechanism is facilitated, epoxide conversion will increase. As a result, the resins can be tailored to control phase separation and physical properties, and shrinkage stress can be reduced. In pursuit of these objectives, the hybrid monomer METHB was polymerized at temperatures ranging from 30°C to 70°C to obtain apparent activation

  5. Advances in acrylic-alkyd hybrid synthesis and characterization

    NASA Astrophysics Data System (ADS)

    Dziczkowski, Jamie

    2008-10-01

    In situ graft acrylic-alkyd hybrid resins were formed by polymerizing acrylic and acrylic-mixed monomers in the presence of alkyds by introduction of a free radical initiator to promote graft formation. Two-dimensional NMR, specifically gradient heteronuclear multiple quantum coherence (gHMQC), was used to clarify specific graft sites of the hybrid materials. Both individual and mixed-monomer systems were produced to determine any individual monomer preferences and to model current acrylic-alkyd systems. Different classes of initiators were used to determine any initiator effects on graft location. The 2D-NMR results confirm grafting at doubly allylic hydrogens located on the fatty acid chains and the polyol segment of the alkyd backbone. The gHMQC spectra show no evidence of grafting across double bonds on either pendant fatty acid groups or THPA unsaturation sites for any of the monomer or mixed monomer systems. It was also determined that choice of initiator has no effect on graft location. In addition, a design of experiments using response surface methodology was utilized to obtain a better understanding of this commercially available class of materials and relate both the chemical and physical properties to one another. A Box-Behnkin design was used, varying the oil length of the alkyd phase, the degree of unsaturation in the polyester backbone, and acrylic to alkyd ratio. Acrylic-alkyd hybrid resins were reduced with an amine/water mixture. Hydrolytic stability was tested and viscoelastic properties were obtained to determine crosslink density. Cured films were prepared and basic coatings properties were evaluated. It was found that the oil length of the alkyd is the most dominant factor for final coatings properties of the resins. Acrylic to alkyd ratio mainly influences the resin properties such as acid number, average molecular weight, and hydrolytic stability. The degree of unsaturation in the alkyd backbone has minimal effects on resin and film

  6. [Anterior pituitary hypersecretion syndromes].

    PubMed

    Gómez, F; Steinhäuslin, F; Crottaz, B; Temler, E

    1987-01-17

    Anterior pituitary hypersecretion can be due to abnormal hypothalamic regulation, decreased peripheral hormone feedback or pituitary tumor. In some cases hypersecretion gives rise to a typical clinical syndrome involving acromegaly, hyperprolactinemia, and excess corticotropin (ACTH). The etiology of acromegaly is a growth hormone (GH)-secreting pituitary tumor in the vast majority of cases. Hyperprolactinemia and excess cortisol, however, may be due to many causes among which prolactin (PRL)- and ACTH-secreting pituitary tumors are not frequent. Glycoprotein-secreting pituitary tumors, especially gonadotropin (LH and FSH) and free subunits usually do not cause a typical excess hormone syndrome. Perhaps for this reason they are seldom recognized clinically, although histopathological studies are increasingly disclosing the gonadotrope nature of many pituitary tumors. Mixed hormonal secretions are common. When pituitary hormone secretion can be selectively suppressed by medical therapy, a significant reduction of tumor size is by no means rare. In other cases, pituitary irradiation or surgery, or even treatment aimed at a peripheral target gland, may be necessary. PMID:3029861

  7. Analysis of emulsion stability in acrylic dispersions

    NASA Astrophysics Data System (ADS)

    Ahuja, Suresh

    2012-02-01

    Emulsions either micro or nano permit transport or solubilization of hydrophobic substances within a water-based phase. Different methods have been introduced at laboratory and industrial scales: mechanical stirring, high-pressure homogenization, or ultrasonics. In digital imaging, toners may be formed by aggregating a colorant with a latex polymer formed by batch or semi-continuous emulsion polymerization. Latex emulsions are prepared by making a monomer emulsion with monomer like Beta-carboxy ethyl acrylate (β-CEA) and stirring at high speed with an anionic surfactant like branched sodium dodecyl benzene sulfonates , aqueous solution until an emulsion is formed. Initiator for emulsion polymerization is 2-2'- azobis isobutyramide dehydrate with chain transfer agent are used to make the latex. If the latex emulsion is unstable, the resulting latexes produce a toner with larger particle size, broader particle size distribution with relatively higher latex sedimentation, and broader molecular weight distribution. Oswald ripening and coalescence cause droplet size to increase and can result in destabilization of emulsions. Shear thinning and elasticity of emulsions are applied to determine emulsion stability.

  8. Fracture properties of an acrylic bone cement.

    PubMed

    Bialoblocka-Juszczyk, E; Baleani, M; Cristofolini, L; Viceconti, M

    2008-01-01

    This study investigated experimentally the fracture properties, i.e., the fatigue strength, the resistance to crack propagation and the fracture toughness, of an acrylic bone cement (Cemex RX). The mean endurance limit was determined following the staircase method. The endurance limit was estimated at 9.2 MPa. The fatigue crack propagation rate was measured according to the ASTM E647 standard. The equation of the line fitting the crack growth per cycle (da/dN) versus the stress-intensity factor range (delta K), in a log-log graph, was used to calculate the empirical constants of Paris' law for the selected bone cement: da/dN (m/cycle) = 3.56 x 10(-7) x delta K (MPa x m1/2)5.79. This power-law relationship described well (R2 = 0.96) the growth rate in the stable crack growth region, i.e., in the mid delta K range. The fracture toughness K(IC) of the bone cement was determined according to the ASTM E399 standard. The K(IC) mean value was 1.38 MPa x m1/2. These experimental results provide the set of necessary inputs for numerical studies aimed to investigate the damage accumulation process in the mantle fixing cemented prostheses.

  9. The Edge supersonic transport

    NASA Technical Reports Server (NTRS)

    Agosta, Roxana; Bilbija, Dushan; Deutsch, Marc; Gallant, David; Rose, Don; Shreve, Gene; Smario, David; Suffredini, Brian

    1992-01-01

    As intercontinental business and tourism volumes continue their rapid expansion, the need to reduce travel times becomes increasingly acute. The Edge Supersonic Transport Aircraft is designed to meet this demand by the year 2015. With a maximum range of 5750 nm, a payload of 294 passengers and a cruising speed of M = 2.4, The Edge will cut current international flight durations in half, while maintaining competitive first class, business class, and economy class comfort levels. Moreover, this transport will render a minimal impact upon the environment, and will meet all Federal Aviation Administration Part 36, Stage III noise requirements. The cornerstone of The Edge's superior flight performance is its aerodynamically efficient, dual-configuration design incorporating variable-geometry wingtips. This arrangement combines the benefits of a high aspect ratio wing at takeoff and low cruising speeds with the high performance of an arrow-wing in supersonic cruise. And while the structural weight concerns relating to swinging wingtips are substantial, The Edge looks to ever-advancing material technologies to further increase its viability. Heeding well the lessons of the past, The Edge design holds economic feasibility as its primary focus. Therefore, in addition to its inherently superior aerodynamic performance, The Edge uses a lightweight, largely windowless configuration, relying on a synthetic vision system for outside viewing by both pilot and passengers. Additionally, a fly-by-light flight control system is incorporated to address aircraft supersonic cruise instability. The Edge will be produced at an estimated volume of 400 aircraft and will be offered to airlines in 2015 at $167 million per transport (1992 dollars).

  10. Effect of curing cycle on the tensile strength of the bond between heat cured denture base acrylic resin and acrylic resin denture teeth.

    PubMed

    Dalal, Ayesha; Juszczyk, Andrzej S; Radford, David R; Clark, Robert K F

    2009-12-01

    The effect of different curing cycles on the tensile strength of the bond between one brand of cross-linked acrylic resin teeth and three heat cured denture base acrylic resins was tested. There were differences in the tensile bond strength between the three heat cured denture base acrylic resins and the three curing cycles used. The bond strength of the acrylic resin denture base material made by the same manufacturer as the cross-linked acrylic resin denture teeth was higher. The bond strength following the short cycle was lowest in all cases, individual differences between curing cycles failed to reach statistical significance. PMID:20158054

  11. Anterior Knee Pain (Chondromalacia Patellae).

    ERIC Educational Resources Information Center

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  12. Extended Klein edges in graphene.

    PubMed

    He, Kuang; Robertson, Alex W; Lee, Sungwoo; Yoon, Euijoon; Lee, Gun-Do; Warner, Jamie H

    2014-12-23

    Graphene has three experimentally confirmed periodic edge terminations, zigzag, reconstructed 5-7, and arm-chair. Theory predicts a fourth periodic edge of graphene called the extended Klein (EK) edge, which consists of a series of single C atoms protruding from a zigzag edge. Here, we confirm the existence of EK edges in both graphene nanoribbons and on the edge of bulk graphene using atomic resolution imaging by aberration-corrected transmission electron microscopy. The formation of the EK edge stems from sputtering and reconstruction of the zigzag edge. Density functional theory reveals minimal energy for EK edge reconstruction and bond distortion both in and out of plane, supporting our TEM observations. The EK edge can now be included as the fourth member of observed periodic edge structures in graphene.

  13. Properties on the edge: graphene edge energies, edge stresses, edge warping, and the Wulff shape of graphene flakes

    NASA Astrophysics Data System (ADS)

    Branicio, Paulo S.; Jhon, Mark H.; Gan, Chee Kwan; Srolovitz, David J.

    2011-07-01

    It has been shown that the broken bonds of an unreconstructed graphene edge generate compressive edge stresses leading to edge warping. Here, we investigate edge energies and edge stresses of graphene nanoribbons with arbitrary orientations from armchair to zigzag, considering both flat and warped edge shapes in the presence and absence of hydrogen. We use the second generation reactive empirical bond order potential to calculate the edge energies and stresses for clean and hydrogenated edges. Using these energies, we perform a Wulff construction to determine the equilibrium shapes of flat graphene flakes as a function of hydrogen chemical potential. While edge stresses for clean, flat edges are compressive, they become tensile if allowed to warp. Conversely, we find that edge energies change little (~1%) with edge warping. Hydrogenation of the edges virtually eliminates both the edge energy and edge stresses. For warped edges an approximately linear relationship is found between amplitudes and wavelengths. The equilibrium shape of a graphene flake is determined by the value of the hydrogen chemical potential. For very small (and large) values of it the flakes have a nearly hexagonal (dodecagon) shape with zigzag oriented edges, while for intermediate values graphene flakes are found with complex shapes.

  14. Esthetic rehabilitation of anterior conoid teeth: comprehensive approach for improved and predictable results.

    PubMed

    Pena, Carlos E; Viotti, Ronaldo G; Dias, Walter R; Santucci, Edward; Rodrigues, Jose A; Reis, Andre F

    2009-01-01

    The esthetic success of a dental treatment depends on the correct diagnosis, treatment plan and clinical and laboratory procedures. This clinical report describes a diagnostically based protocol for conservative preparations on anterior teeth for adhesively retained composite and porcelain restorations. The diagnostic additive wax-up, periodontal esthetic crown-lengthening, direct acrylic mock-up, conservative preparations for ceramic laminate veneers, luting procedures, direct restorations with composite resin used for the esthetic rehabilitation of a patient presenting conoid lateral incisors, and an unsatisfactory class IV restoration in the left central incisor are presented. An accurate diagnostic and interdisciplinary approach is necessary for obtaining improved, conservative and predictable esthetic results in esthetically compromised areas, such as the anterior maxillary dentition.

  15. Bilateral spontaneous anterior dislocation of intraocular lens with the capsular bag in a patient with pseudoexfoliation

    PubMed Central

    Bhattacharjee, Harsha; Saxena, Rushil Kumar; Medhi, Jnanankar

    2015-01-01

    We report a rare case of bilateral spontaneous anterior partial in-the-bag intraocular lens (IOL) dislocation in a 75-year-old man with pseudoexfoliation (PXF). He underwent uneventful phacoemulsification in both eyes with in-the-bag IOL implantation 9 years back. In the right eye, single piece poly (methyl methacrylate) (PMMA) IOL (+19 D) and in the left eye, single piece acrylic foldable IOL (+19 D) were implanted. An attempt at pharmacological IOL repositioning was unsuccessful. The dislocated IOLs were explanted and exchanged with scleral suture fixated PMMA IOLs. Vision improved to 20/30 in both eyes following surgery, without any associated ocular morbidity. We believe that zonular weakness secondary to PXF, capsular contraction, and myopia together were the predisposing factors for partial anterior dislocation of IOLs and IOL exchange with scleral suture fixation of IOL is a safe and effective treatment option. PMID:26655008

  16. Anterior crossbite correction in primary and mixed dentition with removable inclined plane (Bruckl appliance).

    PubMed

    Jirgensone, Irena; Liepa, Andra; Abeltins, Andris

    2008-01-01

    Anterior crossbite correction in early mixed dentition is highly recommended as this kind of malocclusion do not diminish with age. Uncorrected anterior crossbite may lead to abnormal wear of the lower incisors, dental compensation of mandibular incisors leading to thinning of labial alveolar plate and/or gingival recession. There are several methods for solving this problem. In this article we would like to describe removable inclined plane. This is a removable simple functional appliance on the lower arch (jaw), which works as inclined plane. One of the advantage of the Bruckl appliance is that it can also be used as retention appliance after active treatment as well as it is possible to add acrylic teeth if necessary. Therefore it can be used as a removable partial denture in lower jaw in case where there is a premature loss of the primary teeth. The use of this appliance is illustrated with three cases.

  17. Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Introduction: The most recent advances in ACL reconstruction try to reproduce the anatomic femoral and tibial footprints as close as possible. Creating independent tunnels would allow an optimal of the entry point and the femoral tunnel obliquity, and together with an adequate reamer diameter they wouldreproduce with greater certainty the anatomy. Objective: To compare the radiographic parameters of the femoral and tibial tunnel positions in two groups of patients, one operated with a transtibial and other with transportal anatomic techniques. Materials and Methods: From December 2012 to December 2013, 59 patients with a primary ACL reconstruction divided in two groups, a trans tibial technique (TT), 19 patients, and an transportal one (TP) with 40 patients were prospectively evaluated with AP and lateral X-rays. The femoral tunnel angle, the insertion site with respect of the Blumensaat line, the trans osseous distance, the tibial tunnel position as a percentage of the tibial plateau in the AP and lateral views. And finally the tibial tunnel angle in the AP and Lateral views. Results: The femoral tunnel angle was in the TP group of 45,92º and in the TT one 24,53º, p 0,002. The insertion site percentage of the Blumensaat line was of 20,96 in TP and 20,74 in the TT, p 0,681.Trans osseous distance was in the TP of 3,43 cm and in the TT of 4,79 cm, p <0,000. The tibial tunnel position as a percentage in the AP tibial plateau was of 44,35 in TP and of 40,80 TT with a p of 0,076. The tibial tunnel position as a percentage of the lateral tibial plateau was of 28,70 in TP and 34,53 in TT with a p 0,367. Tibial tunnel angle in the AP was of 73,48º in TP and 62,81 in TT with a p of 0,002, and in the lateral plateau of 114,69º in TP and 112,79º in TT with a p of 0,427. Conclusion: It is possible to create tibial and femoral tunnel in optimal positions but not equal between both groups. Creating independent tunnels allow a more anterior and vertical tibial tunnel

  18. Acrylic Resin Cytotoxicity for Denture Base--Literature Review.

    PubMed

    Goiato, Marcelo C; Freitas, Emily; dos Santos, Daniela; de Medeiros, Rodrigo; Sonego, Mariana

    2015-01-01

    Acrylic resin is a widely used material in clinical practice, and a satisfactory biocompatibility is essential. When the resin polymerization reaction is incomplete, residual monomers are released into the oral cavity. The aim of this study was to evaluate, through a literature review, the cytotoxicity caused by the denture base acrylic resin used, and its components. The selection of published studies was performed on the Pubmed database from January 2008 to July 2013. The keywords used were: "cytotoxicity and acrylic resins", "cytotoxicity and denture base resins" and "cytotoxicity and oral prosthesis". Inclusion criteria were: in vitro studies and literature reviews published in English that evaluated the acrylic resin cytotoxicity for denture base and its components. Studies with no reference to the search strategy were excluded. A total of 182 articles were found. Among these, only 13 were included for writing this review. The MTT test is the most common test used to evaluate acrylic resin cytotoxicity. Auto-polymerized resin is more cytotoxic than heat-polymerized resin because of its higher quantity of residual monomers which cause cell and tissue changes in the oral mucosa. However, more studies are necessary for the development of biocompatible materials.

  19. Impact Delamination and Fracture in Aluminum/Acrylic Sandwich Plates

    NASA Technical Reports Server (NTRS)

    Liaw, Benjamin; Zeichner, Glenn; Liu, Yanxiong; Bowles, Kenneth J. (Technical Monitor)

    2000-01-01

    Impact-induced delamination and fracture in 6061-T6 aluminum/cast acrylic sandwich plates adhered by epoxy were generated in an instrumented drop-weight impact machine. Although only a small dent was produced on the aluminum side when a hemispherical penetrator tup was dropped onto it from a couple of inches, a large ring of delamination at the interface was observed. The delamination damage was often accompanied by severe shattering in the acrylic substratum. Damage patterns in the acrylic layer include radial and ring cracks and, together with delamination at the interface, may cause peeling-off of acrylic material from the sandwich plate. Theory of stress-wave propagation can be used to explain these damage patterns. The impact tests were conducted at various temperatures. The results also show clearly that temperature effect is very important in impact damage. For pure cast acrylic nil-ductile transition (NDT) occurs between 185-195 F. Excessive impact energy was dissipated into fracture energy when tested at temperature below this range or through plastic deformation when tested at temperature above the NDT temperature. Results from this study will be used as baseline data for studying fiber-metal laminates, such as GLARE and ARALL for advanced aeronautical and astronautical applications.

  20. High Speed Edge Detection

    NASA Technical Reports Server (NTRS)

    Prokop, Norman F (Inventor)

    2015-01-01

    Analog circuits for detecting edges in pixel arrays are disclosed. A comparator may be configured to receive an all pass signal and a low pass signal for a pixel intensity in an array of pixels. A latch may be configured to receive a counter signal and a latching signal from the comparator. The comparator may be configured to send the latching signal to the latch when the all pass signal is below the low pass signal minus an offset. The latch may be configured to hold a last negative edge location when the latching signal is received from the comparator.

  1. High Speed Edge Detection

    NASA Technical Reports Server (NTRS)

    Prokop, Norman F (Inventor)

    2016-01-01

    Analog circuits for detecting edges in pixel arrays are disclosed. A comparator may be configured to receive an all pass signal and a low pass signal for a pixel intensity in an array of pixels. A latch may be configured to receive a counter signal and a latching signal from the comparator. The comparator may be configured to send the latching signal to the latch when the all pass signal is below the low pass signal minus an offset. The latch may be configured to hold a last negative edge location when the latching signal is received from the comparator.

  2. Biosynthetic pathway for acrylic acid from glycerol in recombinant Escherichia coli.

    PubMed

    Tong, Wenhua; Xu, Ying; Xian, Mo; Niu, Wei; Guo, Jiantao; Liu, Huizhou; Zhao, Guang

    2016-06-01

    Acrylic acid is an important industrial feedstock. In this study, a de novo acrylate biosynthetic pathway from inexpensive carbon source glycerol was constructed in Escherichia coli. The acrylic acid was produced from glycerol via 3-hydroxypropionaldehyde, 3-hydroxypropionyl-CoA, and acrylyl-CoA. The acrylate production was improved by screening and site-directed mutagenesis of key enzyme enoyl-CoA hydratase and chromosomal integration of some exogenous genes. Finally, our recombinant strain produced 37.7 mg/L acrylic acid under shaking flask conditions. Although the acrylate production is low, our study shows feasibility of engineering an acrylate biosynthetic pathway from inexpensive carbon source. Furthermore, the reasons for limited acrylate production and further strain optimization that should be performed in the future were also discussed. PMID:26782744

  3. Nucleophilic addition of reactive dyes on amidoximated acrylic fabrics.

    PubMed

    El-Shishtawy, Reda M; El-Zawahry, Manal M; Abdelghaffar, Fatma; Ahmed, Nahed S E

    2014-01-01

    Seven reactive dyes judiciously selected based on chemical structures and fixation mechanisms were applied at 2% of of shade on amidoximated acrylic fabrics. Amidoximated acrylic fabric has been obtained by a viable amidoximation process. The dyeability of these fabrics was evaluated with respect to the dye exhaustion, fixation, and colour strength under different conditions of temperature and dyeing time. Nucleophilic addition type reactive dyes show higher colour data compared to nucleophilic substitution ones. FTIR studies further implicate the binding of reactive dyes on these fabrics. A tentative mechanism is proposed to rationalize the high fixation yield obtained using nucleophilic addition type reactive dyes. Also, the levelling and fastness properties were evaluated for all dyes used. Excellent to good fastness and levelling properties were obtained for all samples irrespective of the dye used. The result of investigation offers a new method for a viable reactive dyeing of amidoximated acrylic fabrics.

  4. Properties of the modified cellulosic fabrics using polyurethane acrylate copolymers.

    PubMed

    Tabasum, Shazia; Zuber, Mohammad; Jabbar, Abdul; Zia, Khalid Mahmood

    2013-05-15

    Polyurethane acrylate copolymers (PAC) were synthesized via emulsion polymerization following three step synthesis process using toluene-2,4-diisocyanate, hydroxy terminated poly(caprolactone) diol, 2-hydroxyethylacrylate (HEA) and butyl acrylate (BuA). Structural characteristics of the synthesized polyurethane acrylate copolymer (PAC) were studied using Fourier Transform Infrared (FT-IR) spectrophotometer and are with accordance with the proposed PAC structure. The physicochemical properties such as solid contents (%), tackiness, film appearance and emulsion stability were studied, discussed and co-related with other findings. The plain weave poly-cotton printed fabrics after application of PAC was evaluated applying colorfastness standard test method. The results revealed that emulsion stability is the main controlling factor of the synthesized material in order to get better applications and properties. The emulsion stability of the synthesized material increased with increase in molecular weight of the polycaprolactone diol. PMID:23544644

  5. Properties of the modified cellulosic fabrics using polyurethane acrylate copolymers.

    PubMed

    Tabasum, Shazia; Zuber, Mohammad; Jabbar, Abdul; Zia, Khalid Mahmood

    2013-05-15

    Polyurethane acrylate copolymers (PAC) were synthesized via emulsion polymerization following three step synthesis process using toluene-2,4-diisocyanate, hydroxy terminated poly(caprolactone) diol, 2-hydroxyethylacrylate (HEA) and butyl acrylate (BuA). Structural characteristics of the synthesized polyurethane acrylate copolymer (PAC) were studied using Fourier Transform Infrared (FT-IR) spectrophotometer and are with accordance with the proposed PAC structure. The physicochemical properties such as solid contents (%), tackiness, film appearance and emulsion stability were studied, discussed and co-related with other findings. The plain weave poly-cotton printed fabrics after application of PAC was evaluated applying colorfastness standard test method. The results revealed that emulsion stability is the main controlling factor of the synthesized material in order to get better applications and properties. The emulsion stability of the synthesized material increased with increase in molecular weight of the polycaprolactone diol.

  6. Biocatalytic functionalization of hydroxyalkyl acrylates and phenoxyethanol via phosphorylation.

    PubMed

    Tasnádi, Gábor; Hall, Mélanie; Baldenius, Kai; Ditrich, Klaus; Faber, Kurt

    2016-09-10

    The enzymatic phosphorylation of phenoxyethanol, 2-hydroxyethyl acrylate and 4-hydroxybutyl acrylate catalyzed by acid phosphatases PhoN-Sf and PiACP at the expense of inorganic di-, tri-, hexameta- or polyphosphate was applied to the preparative-scale synthesis of phosphorylated compounds. The reaction conditions were optimized with respect to enzyme immobilization, substrate concentration, pH and type of phosphate donor. The mild reaction conditions prevented undesired polymerization and hydrolysis of the acrylate ester moiety. Application of a continuous flow system allowed facile scale-up and mono-phosphates were obtained in up to 26% isolated yield with space-time yields of 0.89kgL(-1)h(-1). PMID:27422352

  7. Biocatalytic functionalization of hydroxyalkyl acrylates and phenoxyethanol via phosphorylation.

    PubMed

    Tasnádi, Gábor; Hall, Mélanie; Baldenius, Kai; Ditrich, Klaus; Faber, Kurt

    2016-09-10

    The enzymatic phosphorylation of phenoxyethanol, 2-hydroxyethyl acrylate and 4-hydroxybutyl acrylate catalyzed by acid phosphatases PhoN-Sf and PiACP at the expense of inorganic di-, tri-, hexameta- or polyphosphate was applied to the preparative-scale synthesis of phosphorylated compounds. The reaction conditions were optimized with respect to enzyme immobilization, substrate concentration, pH and type of phosphate donor. The mild reaction conditions prevented undesired polymerization and hydrolysis of the acrylate ester moiety. Application of a continuous flow system allowed facile scale-up and mono-phosphates were obtained in up to 26% isolated yield with space-time yields of 0.89kgL(-1)h(-1).

  8. Oscillating edge-flames

    NASA Astrophysics Data System (ADS)

    Buckmaster, J.; Zhang, Yi

    1999-09-01

    It has been known for some years that when a near-limit flame spreads over a liquid pool of fuel, the edge of the flame can oscillate. It is also known that when a near-asphyxiated candle-flame burns in zero gravity, the edge of the (hemispherical) flame can oscillate violently prior to extinction. We propose that these oscillations are nothing more than a manifestation of the large Lewis number instability well known in chemical reactor studies and in combustion studies, one that is exacerbated by heat losses. As evidence of this we examine an edge-flame confined within a fuel-supply boundary and an oxygen-supply boundary, anchored by a discontinuity in data at the fuel-supply boundary. We show that when the Lewis number of the fuel is 2, and the Lewis number of the oxidizer is 1, oscillations of the edge occur when the Damköhler number is reduced below a critical value. During a single oscillation period there is a short premixed propagation stage and a long diffusion stage, behaviour that has been observed in flame spread experiments. Oscillations do not occur when both Lewis numbers are equal to 1.

  9. Colour Stability of Heat and Cold Cure Acrylic Resins

    PubMed Central

    Ganesh, P R; Reddy, Madan Mohan; Ebenezar, A.V. Rajesh; Sivakumar, G

    2015-01-01

    Introduction: To evaluate the colour stability of heat and cold cure acrylic resins under simulated oral conditions with different colorants. Materials and Methods: Three different brands of heat cure acrylic resin and two rapid cure auto polymerizing acrylic resin of commercial products such as Trevelon Heat Cure (THC), DPI Heat cure (DHC), Pyrax Heat Cure (PHC), DPI Cold cure (DCC) and Acralyn-R-Cold cure (ACC) have been evaluated for discoloration and colour variation on subjecting it to three different, commonly employed food colorants such as Erythrosine, Tartarizine and Sunset yellow. In order to simulate the oral condition the food colorants were diluted with artificial saliva to the samples taken up for the study. These were further kept in an incubator at 37°C ± 1°C. The UV-visible spectrophotometer has been utilized to evaluate the study on the basis of CIE L* a* b* system. The prepared samples for standard evaluation have been grouped as control group, which has been tested with a white as standard, which is applicable for testing the colour variants. Results: The least colour changes was found to be with Sunset Yellow showing AE* value of 3.55 with heat cure acrylic resin branded as PHC material and the highest colour absorption with Tartarizine showing AE* value of 12.43 in rapid cure autopolymerzing acrylic resin material branded as ACC material. Conclusion: ACC which is a self cure acrylic resin shows a higher colour variation to the tartarizine food coloration. There were not much of discoloration values shown on the denture base resins as the food colorants are of organic azodyes. PMID:25738078

  10. Technology and the use of acrylics for provisional dentine protection.

    PubMed

    Kapusevska, Biljana; Dereban, Nikola; Popovska, Mirjana; Nikolovska, Julijana; Radojkova Nikolovska, Vеrа; Zabokova Bilbilova, Efka; Mijoska, Aneta

    2013-01-01

    Acrylics are compounds polymerized from monomers of acrylic, metacrylic acid or acrylonitrates. The purpose of this paper is to present the technology and use of acrylics for provisional dentine protection in the practice of dental prosthodontics. For this reason, we followed 120 clinical cases from the everyday clinical practice, divided into 4 groups of 30 patients who needed prosthetic reconstruction. The first group included cases in which we applied celluloid crowns for dentine protection, for the second group we used acrylic teeth from a set of teeth for complete dentures; in the third and fourth groups the fabrication was done with the system of an impression matrix and the acrylic resin block technique respectively. In all the examined patients, the gingival index by Silness and Loe and the vitality of the dental pulp were verified clinically, after preparation and 8 days from the placement of the provisional crown. The value for dental sensitivity measured after preparation was 2.59, and 8 days after the placement of the provisional crown it bwas 3.1. From these results we can conclude that after the 8th day from the placement of the provisional crown, there was an adaptation period, characterized by a decrease in the painful sensations. The value of the Silness and Loe gingival index measured after the preparation was 1.34, and 8 days from the placement of the provisional crown was 0.94. The results inclined us to the fact that the provisional acrylic crowns facilitated the reparation of the periodontal tissue. PMID:24566021

  11. Anterior Orbit and Adnexal Amyloidosis

    PubMed Central

    Al Hussain, Hailah; Edward, Deepak P.

    2013-01-01

    Purpose: To describe six cases of anterior orbital and adnexal amyloidosis and to report on proteomic analysis to characterize the nature of amyloid in archived biopsies in two cases. Materials and Methods: The clinical features, radiological findings, pathology, and outcome of six patients with anterior orbit and adnexal amyloidosis were retrieved from the medical records. The biochemical nature of the amyloid was determined using liquid chromatography/mass spectroscopy archived paraffin-embedded tissue in two cases. Results: Of the six cases, three had unilateral localized anterior orbit and lacrimal gland involvement. Four of the six patients were female with an average duration of 12.8 years from the time of onset to presentation eyelid infiltration by amyloid caused ptosis in five cases. CT scan in patients with lacrimal gland involvement (n = 3) demonstrated calcified deformable anterior orbital masses and on pathological exmaintionamyloid and calcific deposits replaced the lacrimal gland acini. Ptosis repair was performed in three patients with good outcomes. One patient required repeated debulking of the mass and one patient had recurrenct disease. Proteomic analysis revealed polyclonal IgG-associated amyloid deposition in one patient and AL kappa amyloid in the second patient. Conclusion: Amyloidosis of the anterior orbit and lacrimal gland can present with a wide spectrum of findings with good outcomes after surgical excision. The nature of amyloid material can be precisely determined in archival pathology blocks using diagnostic proteomic analysis. PMID:24014979

  12. The creep behavior of acrylic denture base resins.

    PubMed

    Sadiku, E R; Biotidara, F O

    1996-01-01

    The creep behavior of acrylic dental base resins, at room temperature and at different loading conditions, has been examined. The behaviors of these resins are similar to that of "commercial perspex" at room temperature over a period of 1000 seconds. The pseudo-elastic moduli of the blends of PMMA VC show a significant increase compared with PMMA alone. The addition of the PVC powder to the heat-cured acrylic resin increased the time-dependent elastic modulus. This increase in elastic modulus is advantageous in the production of denture based resins of improv mechanical properties.

  13. Kinetic relationships governing addition of methanol to methyl acrylate

    SciTech Connect

    Chubarov, G.A.; Danov, S.M.; Kutnyaya, M.Yu.

    1988-11-10

    The kinetic relationships governing the addition of methanol to methyl acrylate and the reverse reaction, i.e., the elimination of methanol from methyl /beta/-methoxypropionate catalyzed by sulfuric and p-toluenesulfonic acids, were investigated. The rate of the forward reaction depends on the concentrations of methyl acrylate, methanol, and the catalyst, and the rate of the reverse reaction depends on the concentration of methyl /beta/-methoxypropionate and of the catalyst. A kinetic expression which describes the process well was obtained.

  14. Corrosion resistant properties of polyaniline acrylic coating on magnesium alloy

    NASA Astrophysics Data System (ADS)

    Sathiyanarayanan, S.; Azim, S. Syed; Venkatachari, G.

    2006-12-01

    The performance of the paint coating based on acrylic-polyaniline on magnesium alloy ZM 21 has been studied by electrochemical impedance spectroscopy in 0.5% NaCl solution. The polyaniline was prepared by chemical oxidative method of aniline with ammonium persulphate in phosphoric acid medium. The phosphate-doped polyaniline was characterized by FTIR and XRD methods. Acrylic paint containing the phosphate-doped polyaniline was prepared and coated on magnesium ZM 21 alloy. The coating was able to protect the magnesium alloy and no base metal dissolution was noted even after 75 days exposure to sodium chloride solution.

  15. Cardiovascular effects of acrylic bone cement in rabbits and cats.

    PubMed

    Pelling, D; Butterworth, K R

    1973-06-16

    The cardiovascular responses to forcing acrylic bone cement, Plasticine, or soft paraffin wax into the medullary cavity of the femur have been studied in rabbits and cats. An acute fall in blood pressure, occurring within a few seconds of insertion, was demonstrated with each substance. In a few of the animals the blood pressure response had a second more protracted component and it is suggested that more than one mechanism is involved. The cardiovascular effects that have been observed in man when acrylic cement is used in prosthetic hip surgery also may be due to more than one mechanism. PMID:4714847

  16. Lipase-catalyzed aza-Michael reaction on acrylate derivatives.

    PubMed

    Steunenberg, Peter; Sijm, Maarten; Zuilhof, Han; Sanders, Johan P M; Scott, Elinor L; Franssen, Maurice C R

    2013-04-19

    A methodology has been developed for an efficient and selective lipase-catalyzed aza-Michael reaction of various amines (primary and secondary) with a series of acrylates and alkylacrylates. Reaction parameters were tuned, and under the optimal conditions it was found that Pseudomonas stutzeri lipase and Chromobacterium viscosum lipase showed the highest selectivity for the aza-Michael addition to substituted alkyl acrylates. For the first time also, some CLEAs were examined that showed a comparable or higher selectivity and yield than the free enzymes and other formulations.

  17. ANTERIOR LENS CAPSULE MANAGEMENT IN PEDIATRIC CATARACT SURGERY

    PubMed Central

    Wilson, M. Edward

    2004-01-01

    ABSTRACT Purpose To describe and analyze pediatric anterior capsulotomy techniques and make recommendations. Methods Five anterior capsulotomy techniques were compared using a porcine model. Extensibility was measured by calculating the mean stretch-to-rupture circumference of each capsulotomy (20 eyes per technique) as a percentage of its circumference at rest. Edge characteristics were reviewed using scanning electron microscopy. A 10-year review of consecutive pediatric cataract surgeries performed by the author focused on the anterior capsulotomy results. A worldwide survey was used to determine current practice patterns. Results Manual continuous curvilinear capsulorrhexis (CCC) produced the most extensible porcine capsulotomy (185%) with the most regular edge and is preferred by surgeons for patients aged 2 years and older. In the pseudophakic clinical cases reviewed, a radial tear developed in 3 (6.5%) of 46 manual CCC cases. Vitrectorhexis (porcine extensibility, 161%) is preferred by surgeons during the first 2 years of life. A radial tear developed in 16 (7.7%) of 208 vitrectorhexis pseudophakic eyes (29 tears in 284 pseudophakic eyes [10.2%] overall). The Kloti diathermy unit, Fugo plasma blade, and “can-opener” technique produced porcine capsulotomies of 145%, 170%, and 149% extensibility, respectively, and radial tears numbering 4 (21%) of 19, 5 of 8, and 1 of 2, respectively, in the clinical series. Conclusions All five capsulotomy techniques are recommendable for children. Only the vitrectorhexis and manual CCC are commonly used today. Vitrectorhexis is well suited for use in infants and young children; manual CCC is best used beyond infancy, and it produces the most stable edge. PMID:15747769

  18. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  19. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  20. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section...

  1. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  2. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  3. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  4. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  5. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  6. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  7. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  8. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  9. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  10. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  11. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section...

  12. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section...

  13. 40 CFR 721.10101 - Copolymer of alkyl acrylate and ethyleneglycol dimethacrylate (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Copolymer of alkyl acrylate and... Significant New Uses for Specific Chemical Substances § 721.10101 Copolymer of alkyl acrylate and...) The chemical substance identified generically as copolymer of alkyl acrylate and...

  14. 40 CFR 721.10101 - Copolymer of alkyl acrylate and ethyleneglycol dimethacrylate (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Copolymer of alkyl acrylate and... Significant New Uses for Specific Chemical Substances § 721.10101 Copolymer of alkyl acrylate and...) The chemical substance identified generically as copolymer of alkyl acrylate and...

  15. 40 CFR 721.10101 - Copolymer of alkyl acrylate and ethyleneglycol dimethacrylate (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Copolymer of alkyl acrylate and... Significant New Uses for Specific Chemical Substances § 721.10101 Copolymer of alkyl acrylate and...) The chemical substance identified generically as copolymer of alkyl acrylate and...

  16. 40 CFR 721.10101 - Copolymer of alkyl acrylate and ethyleneglycol dimethacrylate (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Copolymer of alkyl acrylate and... Significant New Uses for Specific Chemical Substances § 721.10101 Copolymer of alkyl acrylate and...) The chemical substance identified generically as copolymer of alkyl acrylate and...

  17. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-methyl acrylate copolymer resins. 177.1340... copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used as articles or components of...) For the purpose of this section, the ethylene-methyl acrylate copolymer resins consist of...

  18. 40 CFR 721.10192 - Amides, coco, N-[3-(dibutylamino)propyl], acrylates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Amides, coco, N- , acrylates. 721... Substances § 721.10192 Amides, coco, N- , acrylates. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as amides, coco, N- , acrylates (PMN...

  19. 40 CFR 721.10192 - Amides, coco, N-[3-(dibutylamino)propyl], acrylates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Amides, coco, N- , acrylates. 721... Substances § 721.10192 Amides, coco, N- , acrylates. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as amides, coco, N- , acrylates (PMN...

  20. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ethylene-methyl acrylate copolymer resins. 177... for Use as Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used...

  1. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ethylene-methyl acrylate copolymer resins. 177... for Use as Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used...

  2. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Ethylene-methyl acrylate copolymer resins. 177... Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl... section, the ethylene-methyl acrylate copolymer resins consist of basic copolymers produced by...

  3. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  4. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  5. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  6. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  7. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section...

  8. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  9. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  10. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  11. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  12. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  13. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  14. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  15. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  16. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  17. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  18. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  19. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  20. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). Link to an amendment published at 79 FR 34636... substances identified generically as salt of an acrylate copolymer (PMNs P-00-0333 and P-00-0334) are...

  1. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  2. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  3. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  4. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  5. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  6. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  7. Superpixel edges for boundary detection

    DOEpatents

    Moya, Mary M.; Koch, Mark W.

    2016-07-12

    Various embodiments presented herein relate to identifying one or more edges in a synthetic aperture radar (SAR) image comprising a plurality of superpixels. Superpixels sharing an edge (or boundary) can be identified and one or more properties of the shared superpixels can be compared to determine whether the superpixels form the same or two different features. Where the superpixels form the same feature the edge is identified as an internal edge. Where the superpixels form two different features, the edge is identified as an external edge. Based upon classification of the superpixels, the external edge can be further determined to form part of a roof, wall, etc. The superpixels can be formed from a speckle-reduced SAR image product formed from a registered stack of SAR images, which is further segmented into a plurality of superpixels. The edge identification process is applied to the SAR image comprising the superpixels and edges.

  8. Influence of Gender on the Patient's Assessment of Restorations on the Upper Anterior Teeth

    PubMed Central

    Žagar, Maja; Zlatarić, Dubravka Knezović

    2014-01-01

    Objective The aim of this study was to assess the level of patients’ satisfaction with appearance of maxillary anterior teeth restorations and to determine if there is a significant difference in patients’ assessment of restoration appearance with regard to gender. Materials and methods Two hundred subjects evaluated the colour, anatomical shape and surface texture of maxillary anterior teeth restorations (composite fillings, acrylic faceted metal crowns, porcelain-fused-to-metal crowns and all-ceramic crowns) in comparison with adjacent natural teeth. The data were expressed in patients’ average assessment scores for colour, anatomical shape and surface texture as well as overall patients’ average assessment scores for every type of restoration and overall patients’ average assessment scores for colour, anatomical shape and surface texture of all the restorations in general. Patients also assessed the general impression of their maxillary anterior teeth restorations and rated it as satisfactory or unsatisfactory. Results There was a statistically significant gender difference in patient assessment of colour and surface texture for composite fillings and the overall patient average assessment score for colour of all assessments (p <0.05). Women were more dissatisfied with the general impression of their restorations on the upper teeth than men (p >0.05). Only overall patients’ average assessment score for composite restorations almost reached the level of significance (p = 0.069) on patients’ general impression. Conclusion Colour of the restorations and the composite material are significant factors which affect dental appearance of maxillary anterior teeth in patients.

  9. Influence of Gender on the Patient's Assessment of Restorations on the Upper Anterior Teeth

    PubMed Central

    Žagar, Maja; Zlatarić, Dubravka Knezović

    2014-01-01

    Objective The aim of this study was to assess the level of patients’ satisfaction with appearance of maxillary anterior teeth restorations and to determine if there is a significant difference in patients’ assessment of restoration appearance with regard to gender. Materials and methods Two hundred subjects evaluated the colour, anatomical shape and surface texture of maxillary anterior teeth restorations (composite fillings, acrylic faceted metal crowns, porcelain-fused-to-metal crowns and all-ceramic crowns) in comparison with adjacent natural teeth. The data were expressed in patients’ average assessment scores for colour, anatomical shape and surface texture as well as overall patients’ average assessment scores for every type of restoration and overall patients’ average assessment scores for colour, anatomical shape and surface texture of all the restorations in general. Patients also assessed the general impression of their maxillary anterior teeth restorations and rated it as satisfactory or unsatisfactory. Results There was a statistically significant gender difference in patient assessment of colour and surface texture for composite fillings and the overall patient average assessment score for colour of all assessments (p <0.05). Women were more dissatisfied with the general impression of their restorations on the upper teeth than men (p >0.05). Only overall patients’ average assessment score for composite restorations almost reached the level of significance (p = 0.069) on patients’ general impression. Conclusion Colour of the restorations and the composite material are significant factors which affect dental appearance of maxillary anterior teeth in patients. PMID:27688349

  10. Treatment of anterior dental crossbite using bonded resin-composite slopes: case reports.

    PubMed

    Bayrak, Sule; Tunc, Emine Sen

    2008-10-01

    Anterior crossbite is the term used to describe an abnormal labiolingual relationship between one or more maxillary and mandibular incisor teeth. Different techniques have been used to correct anterior crossbite. This paper describes the use of bonded resin-composite slopes for the management of anterior crossbite in children in early mixed dentition.In each of the cases presented here, dental crossbite was corrected by applying a 3-4 mm bonded resin-composite slope to the incisal edge of the mandibular incisor with an angle 45 degrees to the longitudinal axis of the tooth. Correction was achieved within 1-2 weeks with no damage to either the tooth or the marginal periodontal tissue. The procedure is a simple and effective method for treating anterior dental crossbite.

  11. Edge magnetoplasmons in graphene

    NASA Astrophysics Data System (ADS)

    Petković, Ivana; Williams, F. I. B.; Glattli, D. Christian

    2014-03-01

    We have observed propagation of edge magnetoplasmon (EMP) modes in graphene in the quantum Hall regime by performing picosecond time-of-flight measurements between narrow contacts on the perimeter of micrometric exfoliated graphene. We find the propagation to be chiral with low attenuation and to have a velocity which is quantized on Hall plateaus. The velocity has two contributions, one arising from the Hall conductivity and the other from carrier drift along the edge, which we were able to separate by their different filling factor dependence. The drift component is found to be slightly less than the Fermi velocity as expected for graphene dynamics in an abrupt edge potential. The Hall conduction contribution is slower than expected and indicates a characteristic length in the Coulomb potential from the Hall charge of about 500 nm. The experiment illustrates how EMP can be coupled to the electromagnetic field, opening the perspective of GHz to THz chiral plasmonics applications to devices such as voltage controlled phase shifters, circulators, switches and compact, tunable ring resonators.

  12. Degradation of a Sodium Acrylate Oligomer by an Arthrobacter sp

    PubMed Central

    Hayashi, Takaya; Mukouyama, Masaharu; Sakano, Kouichi; Tani, Yoshiki

    1993-01-01

    Arthrobacter sp. strain NO-18 was first isolated from soil as a bacterium which could degrade the sodium acrylate oligomer and utilize it as the sole source of carbon. When 0.2% (wt/wt) oligomer was added to the culture medium, the acrylate oligomer was found to be degraded by 70 to 80% in 2 weeks, using gel permeation chromatography. To determine the maximum molecular weight for biodegradation, the degradation test was done with the hexamer, heptamer, and octamer, which were separated from the oligomer mixture by fractional gel permeation chromatography. The hexamer and heptamer were consumed to the extents of 58 and 36%, respectively, in 2 weeks, but the octamer was not degraded. Oligomers with three different terminal groups were synthesized to examine the effect of the different terminal groups on biodegradation, but few differences were found. Arthrobacter sp. NO-18 assimilated acrylic acid, propionic acid, glutaric acid, 2-methylglutaric acid, and 1,3,5-pentanetricarboxylic acid. Degradation of the acrylic unit structure by this strain is discussed. PMID:8517751

  13. Bond strength between acrylic resin and maxillofacial silicone

    PubMed Central

    HADDAD, Marcela Filié; GOIATO, Marcelo Coelho; dos SANTOS, Daniela Micheline; CREPALDI, Nádia de Marchi; PESQUEIRA, Aldiéris Alves; BANNWART, Lisiane Cristina

    2012-01-01

    The development of implant dentistry improved the possibilities of rehabilitation with maxillofacial prosthesis. However, clinically it is difficult to bond the silicone to the attachment system. Objectives This study aimed to evaluate the effect of an adhesive system on the bond strength between acrylic resin and facial silicone. Material and Methods A total of 120 samples were fabricated with auto-polymerized acrylic resin and MDX 4-4210 facial silicone. Both materials were bonded through mechanical retentions and/or application of primers (DC 1205 primer and Sofreliner primer S) and adhesive (Silastic Medical Adhesive Type A) or not (control group). Samples were divided into 12 groups according to the method used to attach the silicone to the acrylic resin. All samples were subjected to a T-peel test in a universal testing machine. Failures were classified as adhesive, cohesive or mixed. The data were evaluated by the analysis of variance (ANOVA) and the Tukey's HSD test (α=.05). Results The highest bond strength values (5.95 N/mm; 3.07 N/mm; 4.75 N/mm) were recorded for the samples that received a Sofreliner primer application. These values were significantly higher when the samples had no scratches and did not receive the application of Silastic Medical Adhesive Type A. Conclusions The most common type of failure was adhesive. The use of Sofreliner primer increased the bond strength between the auto-polymerized acrylic resin and the Silastic MDX 4-4210 facial silicone. PMID:23329247

  14. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Halogenated benzyl ester acrylate (generic). 721.329 Section 721.329 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... substance may cause internal organ effects (kidney and blood). The requirements of this section do not...

  15. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Halogenated benzyl ester acrylate (generic). 721.329 Section 721.329 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... substance may cause internal organ effects (kidney and blood). The requirements of this section do not...

  16. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Halogenated benzyl ester acrylate (generic). 721.329 Section 721.329 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... substance may cause internal organ effects (kidney and blood). The requirements of this section do not...

  17. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Halogenated benzyl ester acrylate (generic). 721.329 Section 721.329 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... substance may cause internal organ effects (kidney and blood). The requirements of this section do not...

  18. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Halogenated benzyl ester acrylate (generic). 721.329 Section 721.329 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... substance may cause internal organ effects (kidney and blood). The requirements of this section do not...

  19. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... and holding food, including heating of prepared food, subject to the provisions of this section: (a... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  20. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... a food-contact surface of articles intended for packaging and holding food, including heating of... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  1. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and holding food, including heating of prepared food, subject to the provisions of this section: (a... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  2. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... and holding food, including heating of prepared food, subject to the provisions of this section: (a... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  3. Acrylic resin injection method for blood vessel investigations.

    PubMed

    Suwa, Fumihiko; Uemura, Mamoru; Takemura, Akimichi; Toda, Isumi; Fang, Yi-Ru; Xu, Yuan Jin; Zhang, Zhi Yuan

    2013-01-01

    The injection of acrylic resin into vessels is an excellent method for macroscopically and microscopically observing their three-dimensional features. Conventional methods can be enhanced by removal of the polymerization inhibitor (hydroquinone) without requiring distillation, a consistent viscosity of polymerized resin, and a constant injection pressure and speed. As microvascular corrosion cast specimens are influenced by viscosity, pressure, and speed changes, injection into different specimens yields varying results. We devised a method to reduce those problems. Sodium hydroxide was used to remove hydroquinone from commercial methylmethacrylate. The solid polymer and the liquid monomer were mixed using a 1 : 9 ratio (low-viscosity acrylic resin, 9.07 ± 0.52 mPa•s) or a 3:7 ratio (high-viscosity resin, 1036.33 ± 144.02 mPa•s). To polymerize the acrylic resin for injection, a polymerization promoter (1.0% benzoyl peroxide) was mixed with a polymerization initiator (0.5%, N, N-dimethylaniline). The acrylic resins were injected using a precise syringe pump, with a 5-mL/min injection speed and 11.17 ± 1.60 mPa injection pressure (low-viscosity resin) and a 1-mL/min injection speed and 58.50 ± 5.75 mPa injection pressure (high-viscosity resin). Using the aforementioned conditions, scanning electron microscopy indicated that sufficient resin could be injected into the capillaries of the microvascular corrosion cast specimens.

  4. JKR studies of adhesion with model acrylic elastomers

    SciTech Connect

    Shull, K.R.; Ahn, D.

    1996-12-31

    Acrylic elastomers are widely used in coating applications because of their inherent thermal stability, oil resistance and adhesive properties. These same features make acrylic elastomers attractive for fundamental studies of polymer adhesion. This endeavor has been simplified recently by the development of techniques for producing monodisperse acrylic homopolymers and block copolymers from anionically synthesized parent polyacrylates, thus allowing precise microstructural control of adhering surfaces. In terms of the adhesion measurement itself, an adhesion test based upon the theory of Johnson, Kendall and Roberts (JKR), henceforth referred to as the JKR technique, is well suited for probing the molecular origins of adhesion in elastomeric systems. This technique is quite practical, and minimizes the sample volume to reduce bulk viscoelastic losses. Further, the JKR technique permits testing at very low crack velocities, where interfacial effects are unobscured by bulk effects. In this paper, the authors report the results of JKR adhesion tests between poly(n-butyl acrylate) (PNBA) elastomers and poly(methyl methacrylate) (PMMA). The latter is employed as a control substrate because its inertness and low surface energy (relative to metallic or silicon based surfaces) are conducive to the creation of reproducible solid surfaces.

  5. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... prescribed in paragraph (c)(2) of this section, when tested by the methods prescribed for polyethylene in... identified by their characteristic infrared spectra. (ii) Quantitative determination of ethyl acrylate... less than 0.920 nor more than 0.935, as determined by ASTM method D1505-68 (Reapproved 1979),...

  6. Antimicrobial activity of poly(acrylic acid) block copolymers.

    PubMed

    Gratzl, Günther; Paulik, Christian; Hild, Sabine; Guggenbichler, Josef P; Lackner, Maximilian

    2014-05-01

    The increasing number of antibiotic-resistant bacterial strains has developed into a major health problem. In particular, biofilms are the main reason for hospital-acquired infections and diseases. Once formed, biofilms are difficult to remove as they have specific defense mechanisms against antimicrobial agents. Antimicrobial surfaces must therefore kill or repel bacteria before they can settle to form a biofilm. In this study, we describe that poly(acrylic acid) (PAA) containing diblock copolymers can kill bacteria and prevent from biofilm formation. The PAA diblock copolymers with poly(styrene) and poly(methyl methacrylate) were synthesized via anionic polymerization of tert-butyl acrylate with styrene or methyl methacrylate and subsequent acid-catalyzed hydrolysis of the tert-butyl ester. The copolymers were characterized via nuclear magnetic resonance spectroscopy (NMR), size-exclusion chromatography (SEC), Fourier transform infrared spectroscopy (FTIR), elemental analysis, and acid-base titrations. Copolymer films with a variety of acrylic acid contents were produced by solvent casting, characterized by atomic force microscopy (AFM) and tested for their antimicrobial activity against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. The antimicrobial activity of the acidic diblock copolymers increased with increasing acrylic acid content, independent of the copolymer-partner, the chain length and the nanostructure.

  7. 40 CFR 721.336 - Perfluoroalkylethyl acrylate copolymer (generic name).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.336 Perfluoroalkylethyl acrylate copolymer (generic name). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified...

  8. 40 CFR 721.336 - Perfluoroalkylethyl acrylate copolymer (generic name).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.336 Perfluoroalkylethyl acrylate copolymer (generic name). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified...

  9. Anterior cruciate ligament - updating article.

    PubMed

    Luzo, Marcus Vinicius Malheiros; Franciozi, Carlos Eduardo da Silveira; Rezende, Fernando Cury; Gracitelli, Guilherme Conforto; Debieux, Pedro; Cohen, Moisés

    2016-01-01

    This updating article on the anterior cruciate ligament (ACL) has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques. PMID:27517015

  10. Anterior cruciate ligament - updating article.

    PubMed

    Luzo, Marcus Vinicius Malheiros; Franciozi, Carlos Eduardo da Silveira; Rezende, Fernando Cury; Gracitelli, Guilherme Conforto; Debieux, Pedro; Cohen, Moisés

    2016-01-01

    This updating article on the anterior cruciate ligament (ACL) has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques.

  11. LC50 values for rats acutely exposed to vapors of acrylic and methacrylic acid esters

    SciTech Connect

    Oberly, R.; Tansy, M.F.

    1985-01-01

    Acute exposure studies were conducted using adult male Sprague-Dawley rats to obtain LC50/24 concentrations for the common esters of acrylic and methacrylic acids. The order of acute toxicity was determined to be methyl acrylate > ethyl acrylate > butyl acrylate > butyl methacrylate > methyl methacrylate > ethyl methacrylate. Four-hour daily exposures (excluding weekends) of young adult male rats to 110 ppm methyl acrylate in air over a period of 32 d failed to produce significant differences in body or tissue weights, blood chemistries, gross metabolic performance, and spontaneous small-intestinal motor activities when compared with a sham-exposed group.

  12. Synthesis and Characterization of Polyurethane Acrylates for UV Curable Coating Agents

    NASA Astrophysics Data System (ADS)

    Park, Mi Na; Kang, Young Soo; Oh, Sun Wha; Ahn, Byung Hyun; Moon, Myung Jun

    The single hydroxyl-terminated urethane acrylate oligomers were synthesized from 2-mercaptoethanol (2-MEOH), alkyl (methyl, butyl, and 2-ethylhexyl) acrylate, and 2,2-azobisisobutyronitrile (AIBN, initiator), with dibutyltin dilaurate (DBTDL) as a catalyst. 2-MEOH was used as a functional chain transfer agent. Poly(alkyl urethane) acrylate oligomers were obtained by the reaction of single hydroxyl-terminated polyalkyl acrylates and 2-isocyanatoethyl acrylate. They were characterized by NMR, FT-IR spectroscopy, rheometer, and DSC. Because poly(alkyl urethane) acrylate oligomers have lower Tg and viscosity than hydroxyl-terminated polyalkyl acrylate oligomers (HTPAO) non-containing urethane groups, they can be used for ultraviolet (UV) curable coatings, inks, and adhesives.

  13. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens.

    PubMed

    Ventura, Bruna Vieira; MacLean, Kyle Douglas; Lira, Wagner; Oliveira, Daniele Mendes de; Ventura, Camila Vieira; Werner, Liliana

    2016-01-01

    A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.

  14. Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens.

    PubMed

    Ventura, Bruna Vieira; MacLean, Kyle Douglas; Lira, Wagner; Oliveira, Daniele Mendes de; Ventura, Camila Vieira; Werner, Liliana

    2016-01-01

    A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification. PMID:27626152

  15. Hydrophilic Acrylic Intraocular Lens Opacification after Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Norouzpour, Amir; Zarei-Ghanavati, Siamak

    2016-01-01

    Purpose: To report hydrophilic acylic intraocular lens (IOL) opacification after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in an eye with multiple prior intraocular surgeries and iatrogenic aniridia. Case Report: A 34-year-old woman with history of penetrating keratoplasty (PKP) for advanced keratoconus and subsequent Urrets-Zavalia Syndrome (UZS) underwent phacoemulsification and hydrophilic acrylic IOL implantation for her cataract. In order to control post-PKP glaucoma, multiple glaucoma surgeries including two glaucoma drainage implants were performed. As the original corneal graft failed, the patient subsequently underwent re-PKP. Four years later, she underwent DSAEK for treatment of the second graft failure. Ten months after DSAEK, a double semi-circular pattern of IOL opacification was observed on the anterior surface of the IOL. The patient did not report any complaints and we decided not to exchange the IOL. Conclusion: In an eye with UZS and iatrogenic aniridia, IOL opacification may result from direct contact between the IOL surface and exogenous air. Aniridia can be a risk factor for development of IOL opacification after DSAEK. Further studies are required to confirm this hypothesis. PMID:27413506

  16. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it...

  17. Electrochemistry of folded graphene edges.

    PubMed

    Ambrosi, Adriano; Bonanni, Alessandra; Pumera, Martin

    2011-05-01

    There is enormous interest in the investigation of electron transfer rates at the edges of graphene due to possible energy storage and sensing applications. While electrochemistry at the edges and the basal plane of graphene has been studied in the past, the new frontier is the electrochemistry of folded graphene edges. Here we describe the electrochemistry of folded graphene edges and compare it to that of open graphene edges. The materials were characterized in detail by high-resolution transmission electron microscopy, Raman spectroscopy, high-resolution X-ray photoelectron spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry. We found that the heterogeneous electron transfer rate is significantly lower on folded graphene edges compared to open edge sites for ferro/ferricyanide, and that electrochemical properties of open edges offer lower potential detection of biomarkers than the folded ones. It is apparent, therefore, that for sensing and biosensing applications the folded edges are less active than open edges, which should then be preferred for such applications. As folded edges are the product of thermal treatment of multilayer graphene, such thermal procedures should be avoided when fabricating graphene for electrochemical applications.

  18. Automated measurement of anterior and posterior acetabular sector angles

    NASA Astrophysics Data System (ADS)

    Ibragimov, Bulat; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2012-03-01

    In this paper, we propose a segmentation algorithm by which anatomical landmarks on the pelvis are extracted from computed tomography (CT) images. The landmarks are used to automatically define the anterior (AASA) and posterior acetabular sector angles (PASA) describing the degree of hip misalignment. The center of each femoral head is obtained by searching for the point at which most intensity gradient vectors defined at edge points intersect. The radius of each femoral head is computed by finding the sphere, positioned at the center of the femoral head, for which the normalized sum of gradient vector magnitudes on the sphere surface is maximal. The anterior and posterior corners of each acetabulum are searched for on a curve representing the acetabulum and defined by dynamic programming. The femoral head centers and anterior and posterior corners are used to calculate the AASA and PASA. The algorithm was applied to CT images of 120 normal subjects and the results were compared to ground truth values obtained by manual segmentation. The mean absolute difference (+/- standard deviation) between the obtained and ground truth values was 1.3 +/- 0.3 mm for the femoral head centers and 2.1 +/- 1.3 degrees for the acetabular angles.

  19. Wavelength Shifters and Interactions of EDTA with Acrylic & LAB

    NASA Astrophysics Data System (ADS)

    Mohan, Yuvraj; SNO+ Collaboration

    2014-09-01

    The SNO + experiment, an upgrade to the Sudbury Neutrino Observatory, will use linear alkyl-benzene (LAB) liquid scintillator to probe new physics, including 0 νββ decay. Event detection efficiency is heavily affected by radioactive backgrounds, two sources being Rn-222 and Po-210 daughters, some of which has become embedded in the SNO + acrylic vessel after years underground. The leading candidate for polonium leaching is Ethylenediaminetetraacetic acid (EDTA). Before deployment on-site, EDTA's effects on the mechanical integrity of acrylic must be determined. It also must not be soluble in LAB or must be removed before scintillator fill of the vessel, as its presence would result in reduced light yield due to scattering. It was found that EDTA had negligible effects on the Young's Modulus of acrylic. EDTA is also slightly soluble in LAB, but can be completely removed by rinsing with water. Additionally, the study of the light yield and alpha/beta timing profiles of two wavelength shifters - bisMSB and perylene - is critical to determining which should be added to the 0 νββ isotope (tellurium) LAB cocktail. Small-scale results hint that perylene might be better, but this is being confirmed with larger-scale tests. The SNO + experiment, an upgrade to the Sudbury Neutrino Observatory, will use linear alkyl-benzene (LAB) liquid scintillator to probe new physics, including 0 νββ decay. Event detection efficiency is heavily affected by radioactive backgrounds, two sources being Rn-222 and Po-210 daughters, some of which has become embedded in the SNO + acrylic vessel after years underground. The leading candidate for polonium leaching is Ethylenediaminetetraacetic acid (EDTA). Before deployment on-site, EDTA's effects on the mechanical integrity of acrylic must be determined. It also must not be soluble in LAB or must be removed before scintillator fill of the vessel, as its presence would result in reduced light yield due to scattering. It was found that EDTA

  20. The use of acrylic resin oral prosthesis in radiation therapy of oral cavity and paranasal sinus cancer

    SciTech Connect

    Cheng, V.S.T.; Oral, K.; Aramamy, M.A.

    1982-07-01

    In radiation therapy of cancer of the oral cavity and the paranasal sinuses, the extent to which the tissues of the oral cavity are included in the radiation treatment portals will determine the severity of the oral discomfort during treatment. This will affect the nutritional status of the patients, and may eventually affect the total dose of radiation which the patients can receive for treatment of their cancers. In cooperation with the Maxillofacial Prosthetic Department, an acrylic resin oral prosthesis was developed. This prosthesis is easy to use and can be made for each individual patient within 24 hours. It allows for maximum sparing of the normal tissues in the oral cavity and can be modified for shielding of backscattered electrons from heavy metals in the teeth. We have also found that acrylic resin extensions can be built onto the posterior edge of post-maxillectomy obturators; this extension can be used as a carrier for radioactive sources to deliver radiation to deep seated tumor modules in the paranasal sinuses.

  1. Combined Posterior and Anterior Ankle Arthroscopy

    PubMed Central

    Scholten, Peter E.; van Dijk, C. Niek

    2012-01-01

    Treatment of combined anterior and posterior ankle pathology usually consists of either combined anterior and posterior arthrotomies or anterior ankle arthroscopy with an additional posterolateral portal. The first technique bears the risk of complications associated with the extensive exposure, the latter technique provides limited access to the posterior ankle joint. A case is described of combined anterior and posterior arthroscopy, with the patient lying prone and then turned supine, addressing both anterior and posterior ankle pathologies in one tempo. This minimally invasive combined approach allows quick recovery and early return to work and sports activities. PMID:23227391

  2. Chronic pulmonary dysfunction following acute inhalation of butyl acrylate.

    PubMed

    Bhardwaj, Ravindra; Ducatman, Alan; Finkel, Mitchell S; Petsonk, Edward; Hunt, Janet; Beto, Robert J

    2012-01-01

    Butyl Acrylate (BA) (2-propionic acid; CH2 = CHCOOC4H9) is a colorless liquid commonly used in impregnation agents and adhesives. Dermal contact with BA has previously been reported to cause moderate skin irritation with skin sensitizing potential in humans. Health effects of inhalation of BA have not been previously reported. Accordingly, we document the health conditions of a bystander, first responder and landfill worker exposed to butyl acrylate (BA) released to the atmosphere following a collision and roadside spill in October 1998. Retrospective data were collected via chart review and analyzed for exposure, symptoms, physical findings and radiological, laboratory and spirometry results over a ten-year period. All three patients had similar respiratory symptoms including a dramatic hacking cough and dyspnea. Findings included abnormal pulmonary function tests and breath sounds. These data underscore the potential hazards of BA inhalational exposure and the need to wear additional protective equipment. PMID:23472539

  3. A New Process for Acrylic Acid Synthesis by Fermentative Process

    NASA Astrophysics Data System (ADS)

    Lunelli, B. H.; Duarte, E. R.; de Toledo, E. C. Vasco; Wolf Maciel, M. R.; Maciel Filho, R.

    With the synthesis of chemical products through biotechnological processes, it is possible to discover and to explore innumerable routes that can be used to obtain products of high addes value. Each route may have particular advantages in obtaining a desired product, compared with others, especially in terms of yield, productivity, easiness to separate the product, economy, and environmental impact. The purpose of this work is the development of a deterministic model for the biochemical synthesis of acrylic acid in order to explore an alternative process. The model is built-up with the tubular reactor equations together with the kinetic representation based on the structured model. The proposed process makes possible to obtain acrylic acid continuously from the sugar cane fermentation.

  4. Dimensional stability of autopolymerizing acrylic resin impression trays.

    PubMed

    Fehling, A W; Hesby, R A; Pelleu, G B

    1986-05-01

    A study was undertaken to determine the optimal interval between fabrication of an autopolymerizing acrylic resin custom impression tray and making a final impression. Twenty mandibular arch-shaped trays, 10 each of Fastray and Formatray resin, were evaluated for dimensional change. Both materials behaved similarly. Cross-arch contraction of the borders of buccal flanges and unilateral expansion of the borders of buccal-to-lingual flanges were observed. These changes indicate distortion. Linear dimensional changes occurred throughout 6 hours, which suggests that any impression made in a methyl methacrylate acrylic resin custom impression tray should be poured as soon as is conveniently possible. Significant linear dimensional changes were observed for only 40 minutes from the initiation of tray fabrication. This study concludes that while an aged tray is preferred, it is acceptable to make an impression in an autopolymerizing resin custom impression tray after 40 minutes.

  5. Cytotoxicity of denture base acrylic resins: a literature review.

    PubMed

    Jorge, Janaina Habib; Giampaolo, Eunice Teresinha; Machado, Ana Lúcia; Vergani, Carlos Eduardo

    2003-08-01

    Acrylic resins are widely used in the fabrication of denture bases and have been shown to be cytotoxic as a result of substances that leach from the resin. The primary eluate is residual monomer. Numerous reports suggest that residual monomer may be responsible for mucosal irritation and sensitization of tissues. This information is important, not only to assess the biologic effects of such materials, but also to enable a comparison among the different polymerization methods, thus assisting the clinician in selecting a material with minimal cytotoxicity. This article reviews the literature published from 1973 to 2000, selected by use of a Medline search, associated with cytotoxic effects usually ascribed to acrylic denture base materials.

  6. Surface modification of nanoparticles for radiation curable acrylate clear coatings

    NASA Astrophysics Data System (ADS)

    Bauer, F.; Gläsel, H.-J.; Hartmann, E.; Bilz, E.; Mehnert, R.

    2003-08-01

    To obtain transparent, scratch and abrasion resistant coatings a high content of nanosized silica and alumina filler was embedded in radiation-curable acrylate formulations by acid catalyzed silylation using trialkoxysilanes. 29SiMAS NMR and MALDI-TOF mass spectrometry were employed to elucidate the structure of the surface-grafted methacryloxypropyl-, vinyl- and n-propyl-trimethoxysilane. In accordance with NMR findings, MALDI-TOF MS showed highly condensed oligomeric siloxanes of more than 20 monomeric silane units. A ladder-like structure of bound polysiloxanes is proposed rather than a simplified picture of tridentate silane bonding. Hence, silane coupling agents do not only modify the chemical nature of the filler surface but also strongly effect the rheological properties of the acrylate nanodispersions.

  7. Cellular Response to Linear and Branched Poly(acrylic acid).

    PubMed

    Whitty, Elizabeth G; Maniego, Alison R; Bentwitch, Sharon A; Guillaneuf, Yohann; Jones, Mark R; Gaborieau, Marianne; Castignolles, Patrice

    2015-12-01

    Poly(acrylic acid-co-sodium acrylate) (PNaA) is a pH-responsive polymer with potential in anticancer drug delivery. The cytotoxicity and intracellular effects of 3-arm star, hyperbranched and linear PNaA were investigated with L1210 progenitor leukemia cells and L6 myoblast cells. Free solution capillary electrophoresis demonstrated interactions of PNaA with serum proteins. In a 72 h MTT assay most PNaAs exhibited a IC50 between 7 and 14 mmol L(-1), showing that precipitation may be a sufficient purification for PNaA dilute solutions. Dialyzed 3-arm star and hyperbranched PNaA caused an increase in L6 cell viability, challenging the suitability of MTT as cytotoxicity assay for PNaA. Fluorescent confocal microscopy revealed merging of cellular lipids after exposure to PNaA, likely caused by serum starvation.

  8. Precipitation polymerization of acrylic acid in supercritical carbon dioxide

    SciTech Connect

    Romack, T.J.; Maury, E.E.; DeSimone, J.M.

    1995-02-13

    Increasing concern regarding the dissemination of chemical waste (both aqueous and organic) into their environment has prompted considerable interest in new technologies aimed at reducing current waste streams. Processes utilizing carbon dioxide in lieu of conventional solvents for chemical manufacturing and processing provide a viable route to achieving near-zero waste production for these important industries. The authors report the successful precipitation polymerization of acrylic acid in supercritical carbon dioxide at pressure ranging from 125 to 345 bar utilizing AIBN as a free radical initiator. Analyses by gel permeation chromatography (GPC) and scanning electron microscopy (SEM) indicate that for the pressure range studied there is no appreciable effect on product molecular weight, molecular weight distribution, or particle size or morphology. In addition, effective molecular weight control was demonstrated for precipitation polymerizations of acrylic acid in CO{sub 2} through the use of ethyl mercaptan as a chain transfer agent.

  9. Polymerization of acrylic acid using atmospheric pressure DBD plasma jet

    NASA Astrophysics Data System (ADS)

    Bashir, M.; Bashir, S.

    2016-08-01

    In this paper polymerization of acrylic acid was performed using non thermal atmospheric pressure plasma jet technology. The goal of this study is to deposit organic functional coatings for biomedical applications using a low cost and rapid growth rate plasma jet technique. The monomer solution of acrylic acid was vaporized and then fed into the argon plasma for coating. The discharge was powered using a laboratory made power supply operating with sinusoidal voltage signals at a frequency of 10 kHz. The optical emission spectra were collected in order to get insight into the plasma chemistry during deposition process. The coatings were characterized using Fourier transform infrared spectroscopy, atomic force microscopy and growth rates analysis. A high retention of carboxylic functional groups of the monomer was observed at the surface deposited using this low power technique.

  10. Edge remap for solids

    SciTech Connect

    Kamm, James R.; Love, Edward; Robinson, Allen C.; Young, Joseph G.; Ridzal, Denis

    2013-12-01

    We review the edge element formulation for describing the kinematics of hyperelastic solids. This approach is used to frame the problem of remapping the inverse deformation gradient for Arbitrary Lagrangian-Eulerian (ALE) simulations of solid dynamics. For hyperelastic materials, the stress state is completely determined by the deformation gradient, so remapping this quantity effectively updates the stress state of the material. A method, inspired by the constrained transport remap in electromagnetics, is reviewed, according to which the zero-curl constraint on the inverse deformation gradient is implicitly satisfied. Open issues related to the accuracy of this approach are identified. An optimization-based approach is implemented to enforce positivity of the determinant of the deformation gradient. The efficacy of this approach is illustrated with numerical examples.

  11. Edge-on!

    NASA Astrophysics Data System (ADS)

    2007-08-01

    Peering at Uranus's Rings as they Swing Edge-on to Earth for the First Time Since their Discovery in 1977 As Uranus coasts through a brief window of time when its rings are edge-on to Earth - a view of the planet we get only once every 42 years - astronomers peering at the rings with ESO's Very Large Telescope and other space or ground-based telescopes are getting an unprecedented view of the fine dust in the system, free from the glare of the bright rocky rings. They may even find a new moon or two. ESO PR Photo 37/07 ESO PR Photo 37/07 The Uranus System "ESO's VLT took data at the precise moment when the rings were edge-on to Earth," said Imke de Pater, of University of California, Berkeley who coordinated the worldwide campaign. She worked with two team members observing in Chile: Daphne Stam of the Technical University Delft in the Netherlands and Markus Hartung of ESO. The observations were done with NACO, one of the adaptive optics instruments installed at the VLT. With adaptive optics, it is possible to obtain images almost free from the blurring effect of the atmosphere. It is as if the 8.2-m telescope were observing from space. Observations were also done with the Keck telescope in Hawaii, the Hubble Space Telescope, and at the Palomar Observatory. "Using different telescopes around the world allows us to observe as much of the changes during the ring-plane crossing as possible: when Uranus sets as seen from the VLT, it can still be observed by the Keck," emphasised Stam. Uranus orbits the Sun in 84 years. Twice during a Uranian year, the rings appear edge-on to Earth for a brief period. The rings were discovered in 1977, so this is the first time for a Uranus ring-crossing to be observed from Earth. The advantage of observations at a ring-plane crossing is that it becomes possible to look at the rings from the shadowed or dark side. From that vantage point, the normally bright outer rings grow fainter because their centimetre- to metre-sized rocks obscure

  12. Acrylate functionalized tetraalkylammonium salts with ionic liquid properties.

    PubMed

    Grothe, Dorian C; Meyer, Wolfdietrich; Janietz, Silvia

    2012-01-01

    Acrylate functionalized ionic liquids based on tetraalkylammonium salts with terminal acrylates- and methylacrylates were synthesized. Melting points and ionic conductivity of twenty compounds in six groups were determined. Within one group the effect of three different counterions was investigated and discussed. The groups differ in cationic structure elements because of their functional groups such as acrylate and methacrylate, alkyl residues at the nitrogen and number of quaternary ammonium atoms within the organic cation. The effect of these cationic structure elements has been examined concerning the compiled parameters with a view to qualifying them as components for solid state electrolytes. The newly synthesized ionic liquids were characterized by NMR and FTIR analysis. The exchange of halide ions like bromide as counter ions to weakly coordinating [PF₆]⁻, [OTf]⁻ or [TFSI]⁻ reduces the melting points significantly and leads to an ion conductivity of about 10⁻⁴ S/cm at room temperature. In the case of the dicationic ionic liquid, an ion conductivity of about 10⁻³ S/cm was observed.

  13. Light-curing acrylic resin as an orthodontic baseplate material.

    PubMed

    Brown, J; Kerr, W J

    1998-08-01

    Heat-curing autopolymerizing (self-cure or cold-cure), thermoplastic, and light-curing acrylic resin are the most commonly used orthodontic baseplate materials. While cured acrylic resins present few problems to the patient, in the laboratory acrylic resin has to be sprayed, mixed, or packed in a fume-extraction unit because of the harmful fumes emitted by the raw inflammable chemicals. Light-curing material, on the other hand, is virtually nonflammable and has virtually no aroma. A light-cure technique for the construction of orthodontic baseplates is described. While buildup of the baseplate is slightly slower than for self-cured material, the shorter time involved in trimming and polishing means that overall construction is faster. It is easier to obtain a uniform thickness with light-cured material, and it provides superior fit. These results, however, are subject to more extensive clinical trials. The only apparent disadvantage is the fine powder produced during trimming. Even with a bench equipped with an extraction unit, it is advisable to use a face mask to prevent the inhalation of dust.

  14. Synthesis and properties of acrylic copolymers for ocular implants

    NASA Astrophysics Data System (ADS)

    Reboul, Adam C.

    There is a need for flexible polymers with higher refractive index and extended UV absorbing properties for improved intraocular lenses (IOLs). This research was devoted to the synthesis of new acrylic copolymers for foldable IOLs and to studies concerning IOL polymer properties. New polymers were synthesized from phenylated acrylates copolymerized with N-vinyl carbazole derivatives using bulk free radical addition methods. The copolymers had low Tg values, high refractive index, and were flexible. The N-vinyl carbazole derivatives were characterized by NMR and copolymers were characterized by DSC, UV-Vis, and refractometry. New phenothiazine based UV absorbers with high extinction coefficients were also synthesized for incorporation into ocular materials. Patent disclosures on UV absorbers and high refractive index polymers were prepared. A so called "glistening" phenomenon that occurs in all foldable intraocular lenses currently in clinical use is poorly understood and was studied. Research on this microvoid forming behavior included studies and development of methods to inhibit glistening in low Tg acrylic based copolymers. Glistenings were characterized using SEM and optical microscopy. A novel technique for inhibiting glistening was found and a patent disclosure was prepared.

  15. Acrylic microspheres-based optosensor for visual detection of nitrite.

    PubMed

    Noor, Nur Syarmim Mohamed; Tan, Ling Ling; Heng, Lee Yook; Chong, Kwok Feng; Tajuddin, Saiful Nizam

    2016-09-15

    A new optosensor for visual quantitation of nitrite (NO2(-)) ion has been fabricated by physically immobilizing Safranine O (SO) reagent onto a self-adhesive poly(n-butyl acrylate) [poly(nBA)] microspheres matrix, which was synthesized via facile microemulsion UV lithography technique. Evaluation and optimization of the optical NO2(-) ion sensor was performed with a fiber optic reflectance spectrophotometer. Scanning electron micrograph showed well-shaped and smooth spherical morphology of the poly(nBA) microspheres with a narrow particles size distribution from 0.6 μm up to 1.8 μm. The uniform size distribution of the acrylic microspheres promoted homogeneity of the immobilized SO reagent molecules on the microspheres' surfaces, thereby enhanced the sensing response reproducibility (<5% RSD) with a linear range obtained from 10 to 100 ppm NO2(-) ion. The micro-sized acrylic immobilization matrix demonstrated no significant barrier for diffusion of reactant and product, and served as a good solid state ion transport medium for reflectometric nitrite determination in food samples. PMID:27080889

  16. Formation of acrylic acid from lactic acid in supercritical water

    SciTech Connect

    Mok, W.S.L.; Antal, M.J. Jr. ); Jones, M. Jr. )

    1989-09-15

    Supercritical (SC) water is an unusual medium in which fast and specific heterolytic reactions can be conducted at temperatures as high as 400{degree}C. In supercritical water, lactic acid decomposes into gaseous and liquid products via three primary reaction pathways. Products of the acid-catalyzed heterolytic decarbonylation pathway are carbon monoxide, water, and acetaldehyde. Products of the homolytic, decarboxylation pathway are carbon dioxide, hydrogen, and acetaldehyde. Products of the heterolytic, dehydration pathway are acrylic acid and water. The intramolecular nucleophilic displacement of the {alpha}-hydroxyl by the carbonyl group of lactic acid, producing {alpha}-propiolactone as an unstable intermediate which subsequently rearranges to become the unsaturated acid, is a likely mechanism for acrylic acid formation, although an intramolecular E2 elimination initiated by attack of the carbonyl oxygen on a methyl hydrogen cannot be ruled out. Support for the former mechanism comes in part from the observed 100% relative yield of acrylic acid from {beta}-propiolactone in SC water.

  17. Edge phonons in black phosphorus

    NASA Astrophysics Data System (ADS)

    Ribeiro, H. B.; Villegas, C. E. P.; Bahamon, D. A.; Muraca, D.; Castro Neto, A. H.; de Souza, E. A. T.; Rocha, A. R.; Pimenta, M. A.; de Matos, C. J. S.

    2016-07-01

    Black phosphorus has recently emerged as a new layered crystal that, due to its peculiar and anisotropic crystalline and electronic band structures, may have important applications in electronics, optoelectronics and photonics. Despite the fact that the edges of layered crystals host a range of singular properties whose characterization and exploitation are of utmost importance for device development, the edges of black phosphorus remain poorly characterized. In this work, the atomic structure and behaviour of phonons near different black phosphorus edges are experimentally and theoretically studied using Raman spectroscopy and density functional theory calculations. Polarized Raman results show the appearance of new modes at the edges of the sample, and their spectra depend on the atomic structure of the edges (zigzag or armchair). Theoretical simulations confirm that the new modes are due to edge phonon states that are forbidden in the bulk, and originated from the lattice termination rearrangements.

  18. Edge phonons in black phosphorus.

    PubMed

    Ribeiro, H B; Villegas, C E P; Bahamon, D A; Muraca, D; Castro Neto, A H; de Souza, E A T; Rocha, A R; Pimenta, M A; de Matos, C J S

    2016-01-01

    Black phosphorus has recently emerged as a new layered crystal that, due to its peculiar and anisotropic crystalline and electronic band structures, may have important applications in electronics, optoelectronics and photonics. Despite the fact that the edges of layered crystals host a range of singular properties whose characterization and exploitation are of utmost importance for device development, the edges of black phosphorus remain poorly characterized. In this work, the atomic structure and behaviour of phonons near different black phosphorus edges are experimentally and theoretically studied using Raman spectroscopy and density functional theory calculations. Polarized Raman results show the appearance of new modes at the edges of the sample, and their spectra depend on the atomic structure of the edges (zigzag or armchair). Theoretical simulations confirm that the new modes are due to edge phonon states that are forbidden in the bulk, and originated from the lattice termination rearrangements. PMID:27412813

  19. Edge phonons in black phosphorus

    PubMed Central

    Ribeiro, H. B.; Villegas, C. E. P.; Bahamon, D. A.; Muraca, D.; Castro Neto, A. H.; de Souza, E. A. T.; Rocha, A. R.; Pimenta, M. A.; de Matos, C. J. S.

    2016-01-01

    Black phosphorus has recently emerged as a new layered crystal that, due to its peculiar and anisotropic crystalline and electronic band structures, may have important applications in electronics, optoelectronics and photonics. Despite the fact that the edges of layered crystals host a range of singular properties whose characterization and exploitation are of utmost importance for device development, the edges of black phosphorus remain poorly characterized. In this work, the atomic structure and behaviour of phonons near different black phosphorus edges are experimentally and theoretically studied using Raman spectroscopy and density functional theory calculations. Polarized Raman results show the appearance of new modes at the edges of the sample, and their spectra depend on the atomic structure of the edges (zigzag or armchair). Theoretical simulations confirm that the new modes are due to edge phonon states that are forbidden in the bulk, and originated from the lattice termination rearrangements. PMID:27412813

  20. Yet another method for marking incisal edges of teeth for bitemark analysis.

    PubMed

    Metcalf, Roger D

    2008-03-01

    Over the years many methods have been proposed and presented for marking or "highlighting" the incisal edges of anterior teeth on a dental stone model -- one of the critical steps in production of transparent overlays for bitemark analysis. A method is presented here that is an extension and refinement of the "paint the edges" method shown at least as early as 1966 by Gustafson. This method uses "invisible ink" and ultraviolet illumination to produce a very high contrast image of the incisal edges of the teeth on the model. The advantages of this new method are that it is nondestructive, it does not leave visible marks on the models, operator subjectivity in selecting the portions of anterior teeth to be highlighted is reduced, and the author submits that this technique lends itself to easy construction of overlays using computer image-processing software such as Adobe Photoshop and ImageJ. PMID:18366575

  1. Edge conduction in vacuum glazing

    SciTech Connect

    Simko, T.M.; Collins, R.E.; Beck, F.A.; Arasteh, D.

    1995-03-01

    Vacuum glazing is a form of low-conductance double glazing using in internal vacuum between the two glass sheets to eliminate heat transport by gas conduction and convection. An array of small support pillars separates the sheets; fused solder glass forms the edge seal. Heat transfer through the glazing occurs by radiation across the vacuum gap, conduction through the support pillars, and conduction through the bonded edge seal. Edge conduction is problematic because it affects stresses in the edge region, leading to possible failure of the glazing; in addition, excessive heat transfer because of thermal bridging in the edge region can lower overall window thermal performance and decrease resistance to condensation. Infrared thermography was used to analyze the thermal performance of prototype vacuum glazings, and, for comparison, atmospheric pressure superwindows. Research focused on mitigating the edge effects of vacuum glazings through the use of insulating trim, recessed edges, and framing materials. Experimentally validated finite-element and finite-difference modeling tools were used for thermal analysis of prototype vacuum glazing units and complete windows. Experimental measurements of edge conduction using infrared imaging were found to be in good agreement with finite-element modeling results for a given set of conditions. Finite-element modeling validates an analytic model developed for edge conduction.

  2. [Effect of acrylate industry wastes on the environment and the prevention of their harmful action].

    PubMed

    Tikhomirov, Iu P

    1991-01-01

    Acrylic and methacrylic++ acids and monomers as raw materials for production of polymers and copolymers are highly and extremely dangerous substances causing chronic intoxication. At low concentrations, acrylates and methacrylates++ have been found to produce not only systemic toxic, but embryotoxic effects. Manufacture of methacrylic++ and acrylic acids and monomers yields waste gases and waters that contain various acrylic compounds as impurities. The sewage treatment system introduced prevents the pollution of reservoirs with these compounds. High concentrations of acrylates and methacrylates are recorded in the sources of waste gases. It is required that fundamentally new waste--free technological processes for production of methacrylates++ and acrylates be designed and introduced and that the waste gas decontamination systems be improved in order to enhance the efficiency of measures to prevent environmental pollution.

  3. Preparation and properties of UV curable acrylic PSA by vinyl bonded graphene oxide

    NASA Astrophysics Data System (ADS)

    Pang, Beili; Ryu, Chong-Min; Jin, Xin; Kim, Hyung-Il

    2013-11-01

    Acrylic pressure sensitive adhesives (PSAs) with higher thermal stability for thin wafer handling were successfully prepared by forming composite with the graphene oxide (GO) nanoparticles modified to have vinyl groups via subsequent reaction with isophorone diisocyanate and 2-hydroxyethyl methacrylate. The acrylic copolymer was synthesized as a base resin for PSAs by solution radical polymerization of ethyl acrylate, 2-ethylhexyl acrylate, and acrylic acid followed by further modification with GMA to have the vinyl groups available for UV curing. The peel strength of PSA decreased with the increase of gel content which was dependent on both modified GO content and UV dose. Thermal stability of UV-cured PSA was improved noticeably with increasing the modified GO content mainly due to the strong and extensive interfacial bonding formed between the acrylic copolymer matrix and GO fillers

  4. Epoxy-acrylic core-shell particles by seeded emulsion polymerization.

    PubMed

    Chen, Liang; Hong, Liang; Lin, Jui-Ching; Meyers, Greg; Harris, Joseph; Radler, Michael

    2016-07-01

    We developed a novel method for synthesizing epoxy-acrylic hybrid latexes. We first prepared an aqueous dispersion of high molecular weight solid epoxy prepolymers using a mechanical dispersion process at elevated temperatures, and we subsequently used the epoxy dispersion as a seed in the emulsion polymerization of acrylic monomers comprising methyl methacrylate (MMA) and methacrylic acid (MAA). Advanced analytical techniques, such as scanning transmission X-ray microscopy (STXM) and peak force tapping atomic force microscopy (PFT-AFM), have elucidated a unique core-shell morphology of the epoxy-acrylic hybrid particles. Moreover, the formation of the core-shell morphology in the seeded emulsion polymerization process is primarily attributed to kinetic trapping of the acrylic phase at the exterior of the epoxy particles. By this new method, we are able to design the epoxy and acrylic polymers in two separate steps, and we can potentially synthesize epoxy-acrylic hybrid latexes with a broad range of compositions. PMID:27078740

  5. Epoxy-acrylic core-shell particles by seeded emulsion polymerization.

    PubMed

    Chen, Liang; Hong, Liang; Lin, Jui-Ching; Meyers, Greg; Harris, Joseph; Radler, Michael

    2016-07-01

    We developed a novel method for synthesizing epoxy-acrylic hybrid latexes. We first prepared an aqueous dispersion of high molecular weight solid epoxy prepolymers using a mechanical dispersion process at elevated temperatures, and we subsequently used the epoxy dispersion as a seed in the emulsion polymerization of acrylic monomers comprising methyl methacrylate (MMA) and methacrylic acid (MAA). Advanced analytical techniques, such as scanning transmission X-ray microscopy (STXM) and peak force tapping atomic force microscopy (PFT-AFM), have elucidated a unique core-shell morphology of the epoxy-acrylic hybrid particles. Moreover, the formation of the core-shell morphology in the seeded emulsion polymerization process is primarily attributed to kinetic trapping of the acrylic phase at the exterior of the epoxy particles. By this new method, we are able to design the epoxy and acrylic polymers in two separate steps, and we can potentially synthesize epoxy-acrylic hybrid latexes with a broad range of compositions.

  6. Apparent fracture toughness of acrylic bone cement: effect of test specimen configuration and sterilization method.

    PubMed

    Lewis, G

    1999-01-01

    The plane strain fracture toughness of Palacos R bone cement was determined using linear elastic fracture mechanics (LEFM) principles and three different test specimen configurations: single edge notched three-point (SENB), rectangular compact tension (RCT), and chevron notched short rod (CNSR). Another aspect of the study was an investigation of the effect of three methods used to sterilize the powder constituents of the cement-none, gamma irradiation and ethylene oxide--on the fracture toughness of the fully polymerized material. A detailed justification is provided for using LEFM. The fracture toughness results obtained using the CNSR specimens were, on average, 14 and 16% higher than those obtained using the SENB and RCT types, respectively. These differences are accounted for in terms of differences in four aspects of these specimen configuration (namely, residual stress effects, loading rate, material inhomogeneity, and the nature of the test). For a given specimen configuration, gamma irradiation produced a statistically significant decrease in fracture toughness which, it is suggested, is due to the concomitant depreciation in molecular weight. For a given cement type, there is no statistically significant difference in fracture toughness results obtained using SENB and RCT specimens. It is thus suggested that either of these configurations can be used to determine the fracture toughness of acrylic bone cement.

  7. Production and characterization of cut resistant acrylic/copolyaramid fibers via bicomponent wet spinning

    NASA Astrophysics Data System (ADS)

    Hipp, Stephen James

    A composite fiber system consisting of a sheath core bicomponent polymer fiber loaded with hard ceramic particles was developed and characterized for use in cut protective clothing. The core component was comprised of a copolyaramid in order to provide high base cut resistance. An acrylic-copolyaramid polymer blend was used for the sheath component to improve processability and provide potential benefits such as dyeability. Lastly, aluminum oxide particles were incorporated into the fiber core to deflect and deform the cutting edge, further improving cut resistance. A series of designed experiments was used to explore the effects of the wet spinning and heat treatment processes on the structure and properties of the bicomponent fiber. Cut strength of the as-spun fibers was highest when the coagulation rate was slow, promoting the formation of a dense, macrovoid free fiber structure. Upon drawing, fibrillar domains developed within the fiber, further improving cut performance. Cut strength was greatly improved by the heat treatment process despite the fibers becoming highly anisotropic. Addition of the hard particle fillers to the bicomponent fibers showed a decrease in cut strength at the fiber level but nearly doubled the cut strength of resulting fabrics. Finally, the processability of the particle loaded bicomponent fibers was evaluated.

  8. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    SciTech Connect

    Tajau, Rida; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik; Ibrahim, Mohammad Izzat; Yunus, Nurulhuda Mohd

    2014-02-12

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough.

  9. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    NASA Astrophysics Data System (ADS)

    Tajau, Rida; Ibrahim, Mohammad Izzat; Yunus, Nurulhuda Mohd; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik

    2014-02-01

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough.

  10. Anterior cruciate ligament tunnel placement.

    PubMed

    Wolf, Brian R; Ramme, Austin J; Britton, Carla L; Amendola, Annunziato

    2014-08-01

    The purpose of this cadaveric study was to analyze variation in anterior cruciate ligament (ACL) tunnel placement between surgeons and the influence of preferred surgical technique and surgeon experience level using three-dimensional (3D) computed tomography (CT). In this study, 12 surgeons drilled ACL tunnels on six cadaveric knees each. Surgeons were divided by experience level and preferred surgical technique (two-incision [TI], medial portal [MP], and transtibial [TT]). ACL tunnel aperture locations were analyzed using 3D CT scans and compared with radiographic ACL footprint criteria. The femoral tunnel location from front to back within the notch demonstrated a range of means of 16% with the TI tunnels the furthest back. A range of means of only 5% was found for femoral tunnel low to high positions by technique. The anterior to posterior tibial tunnel measure demonstrated wider variation than the medial to lateral position. The mean tibial tunnel location drilled by TT surgeons was more posterior than surgeons using the other techniques. Overall, 82% of femoral tunnels and 78% of tibial tunnels met all radiographic measurement criteria. Slight (1-7%) differences in mean tunnel placement on the femur and tibia were found between experienced and new surgeons. The location of the femoral tunnel aperture in the front to back plane relative to the notch roof and the anterior to posterior position on the tibia were the most variable measures. Surgeon experience level did not appear to significantly affect tunnel location. This study provides background information that may be beneficial when evaluating multisurgeon and multicenter collaborative ACL studies.

  11. Anterior femoroacetabular impingement: an update.

    PubMed

    Lequesne, Michel; Bellaïche, Laurence

    2012-05-01

    Anterior femoroacetabular impingement can cause early hip osteoarthritis. The typical patient is an adult younger than 50 years of age, often with a history of sporting activities. The main symptom is intermittent pain triggered by static flexion (low seats) or dynamic flexion (during sporting or occupational activities that require repeated hip flexion). The characteristic physical finding is pain triggered by placing the hip in internal rotation and 70 to 110° of flexion. In additional to anteroposterior and false-profile radiographs, lateral Dunn or Ducroquet views should be obtained on both sides to visualize the anterior part of the head-neck junction. Instead of being concave, the head-neck junction is either flat or convex, causing a cam effect that damages the labrum and anterosuperior cartilage. Non-sphericity of the femoral head with an anterior ovoid bulge induces a similar cam effect. In pincer impingement, which is less common, over-coverage by the anterosuperior acetabular rim pinches the labrum between the rim and the femoral head-neck junction when the hip is flexed. Pincer impingement is related to acetabular retroversion or protrusion. Arthrography coupled with computed tomography or magnetic resonance imaging visualizes the morphological abnormalities (e.g., ovoid shape of the femoral head or retroversion of the acetabulum) and detects secondary lesions such as labral tears or separation or damage to the anterosuperior cartilage. Arthroscopy allows removal of the damaged labrum and correction of the morphological abnormalities via femoroplasty to restore the normal concave shape of the neck and/or acetabuloplasty to eliminate over-coverage. Short- or mid-term results are satisfactory in 75 to 80% of patients. However, the presence of degenerative lesions in about two-thirds of patients at the time of arthroplastic surgery limits the probability of achieving good long-term results. PMID:22281229

  12. The Facilitator's Edge: Group Sessions for Edge-ucators.

    ERIC Educational Resources Information Center

    Handcock, Helen

    The Facilitator's Edge is a workshop series based on the life/work messages of The Edge magazine. The workshops are deigned to help educators, youth workers, and their career practitioners facilitate conscious career building. This manual consists of five group sessions, each focusing on a different career-building theme. "Megatrends and Making it…

  13. Studies on the hydrolysis of biocompatible acrylic polymers having aspirin-moieties.

    PubMed

    Gu, Z W; Li, F M; Feng, X D; Voong, S T

    1983-01-01

    Both the homogeneous and heterogeneous hydrolysis of five new acrylic polymers having aspirin-moieties, i.e. polymers of beta-(acetylsalicylyloxy)ethyl methacrylate, beta-(acetylsalicylyloxy) propyl methacrylate,beta-(acetylsalicylyloxy) ethyl acrylate, beta-hydroxy-gamma-(acetylsalicylyloxy) propyl methacrylate, beta-hydroxy-gamma-(acetylsalicylyloxy) propyl acrylate were investigated in acidic or alkaline medium at 30 degrees C or 60 degrees C, respectively. It was observed that the chief hydrolyzed product is always aspirin with minor amount of salicylic acid.

  14. N-Butyl acrylate polymer composition for solar cell encapsulation and method

    NASA Technical Reports Server (NTRS)

    Gupta, Amitava (Inventor); Ingham, John D. (Inventor); Yavrouian, Andre H. (Inventor)

    1983-01-01

    A polymer syrup for encapsulating solar cell assemblies. The syrup includes uncrosslinked poly(n-butyl)acrylate dissolved in n-butyl acrylate monomer. Preparation of the poly(n-butyl)acrylate and preparation of the polymer syrup is disclosed. Methods for applying the polymer syrup to solar cell assemblies as an encapsulating pottant are described. Also included is a method for solar cell construction utilizing the polymer syrup as a dual purpose adhesive and encapsulating material.

  15. Edge-edge interactions in stacked graphene nanoplatelets

    SciTech Connect

    Cruz Silva, Eduardo; Terrones Maldonado, Humberto; Terrones Maldonado, Mauricio; Jia, Xiaoting; Sumpter, Bobby G; Dresselhaus, M; Meunier, V.

    2013-01-01

    High-resolution transmission electron microscopy (HRTEM) studies show the dynamics of small graphene platelets on larger graphene layers. The platelets move nearly freely to eventually lock in at well-defined positions close to the edges of the larger underlying graphene sheet. While such movement is driven by a shallow potential energy surface described by an interplane interaction, the lock-in position occurs by via edge-edge interactions of the platelet and the graphene surface located underneath. Here we quantitatively study this behavior using van der Waals density functional calculations. Local interactions at the open edges are found to dictate stacking configurations that are different from Bernal (AB) stacking. These stacking configurations are known to be otherwise absent in edge-free two-dimensional (2D) graphene. The results explain the experimentally observed platelet dynamics and provide a detailed account of the new electronic properties of these combined systems.

  16. Giant edge state splitting at atomically precise graphene zigzag edges

    PubMed Central

    Wang, Shiyong; Talirz, Leopold; Pignedoli, Carlo A.; Feng, Xinliang; Müllen, Klaus; Fasel, Roman; Ruffieux, Pascal

    2016-01-01

    Zigzag edges of graphene nanostructures host localized electronic states that are predicted to be spin-polarized. However, these edge states are highly susceptible to edge roughness and interaction with a supporting substrate, complicating the study of their intrinsic electronic and magnetic structure. Here, we focus on atomically precise graphene nanoribbons whose two short zigzag edges host exactly one localized electron each. Using the tip of a scanning tunnelling microscope, the graphene nanoribbons are transferred from the metallic growth substrate onto insulating islands of NaCl in order to decouple their electronic structure from the metal. The absence of charge transfer and hybridization with the substrate is confirmed by scanning tunnelling spectroscopy, which reveals a pair of occupied/unoccupied edge states. Their large energy splitting of 1.9 eV is in accordance with ab initio many-body perturbation theory calculations and reflects the dominant role of electron–electron interactions in these localized states. PMID:27181701

  17. Giant edge state splitting at atomically precise graphene zigzag edges.

    PubMed

    Wang, Shiyong; Talirz, Leopold; Pignedoli, Carlo A; Feng, Xinliang; Müllen, Klaus; Fasel, Roman; Ruffieux, Pascal

    2016-05-16

    Zigzag edges of graphene nanostructures host localized electronic states that are predicted to be spin-polarized. However, these edge states are highly susceptible to edge roughness and interaction with a supporting substrate, complicating the study of their intrinsic electronic and magnetic structure. Here, we focus on atomically precise graphene nanoribbons whose two short zigzag edges host exactly one localized electron each. Using the tip of a scanning tunnelling microscope, the graphene nanoribbons are transferred from the metallic growth substrate onto insulating islands of NaCl in order to decouple their electronic structure from the metal. The absence of charge transfer and hybridization with the substrate is confirmed by scanning tunnelling spectroscopy, which reveals a pair of occupied/unoccupied edge states. Their large energy splitting of 1.9 eV is in accordance with ab initio many-body perturbation theory calculations and reflects the dominant role of electron-electron interactions in these localized states.

  18. Incisal edge reattachment: literature review and treatment perspectives.

    PubMed

    Murchison, D F; Worthington, R B

    1998-07-01

    Anterior crown fractures in children and adolescents are a common form of injury, affecting approximately 25% of that population. Common restorative treatments such as composite bonding, laminate veneers, or full-coverage restorations tend to sacrifice healthy tooth structure and challenge dentists to match the adjacent unrestored dentition. Incisal edge fragment reattachment, including the use of current bonding techniques, is a restorative treatment option that offers the advantages of simplicity, immediate esthetics, and conservatism in cases of dental trauma. This article presents a comprehensive literature review on this restorative technique. It also provides diagnostic and treatment algorithms to simplify and clarify the recommended diagnostic and clinical regimens. PMID:9780892

  19. Acrylic coatings compositions containing polymer-bound hindered amine light stabilizers

    SciTech Connect

    Callais, P.A.

    1993-12-31

    Unique acrylic coatings resins with attached hindered amine light stabilizer (HALS) groups have been developed. They are readily prepared by reacting a hydrazide functionalized HALS with an acrylic polyol resin containing anhydride and/or epoxy groups or with a peroxide functionalized HALS as the polymerization initiator. As a result, the HALS moiety is rendered nonvolatile and nonextractable. Acrylic melamine and acrylic urethane coatings prepared from the polymer-bound light stabilizer resins exhibit outstanding weatherability and durability in both accelerated and outdoor weathering.

  20. Stereopsis after anterior temporal lobectomy.

    PubMed

    Verhoef, Bram-Ernst; Decramer, Thomas; van Loon, Johannes; Goffin, Jan; Van Paesschen, Wim; Janssen, Peter; Theys, Tom

    2016-09-01

    Brain areas critical for stereopsis have been investigated in non-human primates but are largely unknown in the human brain. Microelectrode recordings and functional MRI (fMRI) studies in monkeys have shown that in monkeys the inferior temporal cortex is critically involved in 3D shape categorization. Furthermore, some human fMRI studies similarly suggest an involvement of visual areas in the temporal lobe in depth perception. We aimed to investigate the role of the human anterior temporal neocortex in stereopsis by assessing stereoscopic depth perception before and after anterior temporal lobectomy. Eighteen epilepsy surgery patients were tested, pre- and postoperatively, in 3 different depth discrimination tasks. Sensitivity for local and global disparity was tested in a near-far discrimination task and sensitivity for 3D curvature was assessed in a convex-concave discrimination task, where 3D shapes were presented at different positions in depth. We found no evidence that temporal lobe epilepsy surgery has a significant effect on stereopsis. In contrast with earlier findings, we conclude that local as well as global stereopsis is maintained after unilateral resection of the temporal pole in epilepsy surgery patients. Our findings, together with previous studies, suggest that in humans more posterior visual regions underlie depth perception. PMID:27344239

  1. Rock Segmentation through Edge Regrouping

    NASA Technical Reports Server (NTRS)

    Burl, Michael

    2008-01-01

    Rockster is an algorithm that automatically identifies the locations and boundaries of rocks imaged by the rover hazard cameras (hazcams), navigation cameras (navcams), or panoramic cameras (pancams). The software uses edge detection and edge regrouping to identify closed contours that separate the rocks from the background.

  2. Computer Methods in EDG Education.

    ERIC Educational Resources Information Center

    Mabrey, Robert L.

    1999-01-01

    Presents several computer-related techniques that encourage engineering design graphics (EDG) students to develop knowledge at levels 4 and 5 of Bloom's taxonomy. Contrasts this approach to extend the educational process with the development of training skills at knowledge levels 2 and 3, which are often the sole basis for EDG instruction.…

  3. Use of anterior maxillary distraction osteogenesis in two cleft lip and palate patients

    PubMed Central

    Srivastava, Dhirendra; Ghassemi, Alireza; Ghassemi, Mehrangiz; Showkatbakhsh, Rahman; Jamilian, Abdolreza

    2015-01-01

    Distraction osteogenesis (DO) has become a mainstream surgical technique for patients with jaw deformities. The aim of this study was to report the effect of DO done by a hyrax screw incorporated in an acrylic plate in the treatment of two maxillary deficient cases with cleft lip and palate. Two patients, a 24-year-old female and a 29-year-old male who suffered from maxillary deficiency and cleft lip and palate, were treated by DO. After making vertical cuts between the premolars on both sides and horizontal cuts similar to Le Fort 1, a hyrax screw was mounted on an acrylic plate for the slow anteroposterior expansion of maxillary arch. The expansion was achieved by turning the hyrax screw 0.8 mm per day after the latency period. Treatment was discontinued after achieving satisfactory over jet and occlusion. This study showed that anterior maxillary distraction is a reliable technique for correction of midfacial deformity arising out of cleft lip and palate. Incidences of complications are negligible compared to total maxillary distraction. PMID:26668459

  4. Effect of 5.25 % sodium hypochlorite on color stability of acrylic and silicone based soft liners and a denture base acrylic resin.

    PubMed

    Salloum, Alaa'a M

    2014-06-01

    The purpose of the current study was to investigate the effect of a chemical disinfectant (sodium hypochlorite 5.25 %) on color stability of a denture base acrylic resin and two processed soft denture lining materials of two different types (acrylic-based and silicone-based). Ten specimens from each type of materials tested were made (2 × 20 × 20 mm). All specimens were immersed in sodium hypochlorite (5.25 %). Colorimetric measurements for each specimen were taken before immersion, and after 24 h and 7 days of immersion. Color changes were evaluated using the CIE L*a*b* colorimetric system. Data were statistically analyzed with one-way analysis of variance (ANOVA) (α = 0.05). ANOVA was followed by Bonferroni test to determine which groups differed from each other. ΔE and ΔL* of the silicone-based liner at the 1st and 7th days of immersion were significantly more than of denture base acrylic resin and acrylic-based liner. Change in ΔL* values of denture base acrylic resin and acrylic-based liner was small and statistically insignificant after 24 h of its immersion. However, the increase in ΔL* values of the acrylic-based liner after 7 days of immersion was considerably more than of denture base acrylic resin. Color changes in denture base acrylic resin and soft denture liners tended to increase with longer immersion times, and the color stability of the soft denture liners was influenced by its chemical type.

  5. The Robotic Edge Finishing Laboratory

    SciTech Connect

    Loucks, C.S.; Selleck, C.B.

    1990-08-01

    The Robotic Edge Finishing Laboratory at Sandia National Laboratories is developing four areas of technology required for automated deburring, chamfering, and blending of machined edges: (1) the automatic programming of robot trajectories and deburring processes using information derived from a CAD database, (2) the use of machine vision for locating the workpiece coupled with force control to ensure proper tool contact, (3) robotic deburring, blending, and machining of precision chamfered edges, and (4) in-process automated inspection of the formed edge. The Laboratory, its components, integration, and results from edge finishing experiments to date are described here. Also included is a discussion of the issues regarding implementation of the technology in a production environment. 24 refs., 17 figs.

  6. Incidental Anterior Cruciate Ligament Calcification: Case Report

    PubMed Central

    Hayashi, Hisami; Fischer, Hans

    2016-01-01

    The calcification of knee ligaments is a finding noted only in a handful of case reports. The finding of an anterior cruciate ligament calcification has been reported once in the literature. Comparable studies involving the posterior cruciate ligament, medial collateral ligament and an ossicle within the anterior cruciate ligament are likewise discussed in reports of symptomatic patients. We report a case of incidentally discovered anterior cruciate ligament calcification. We discuss the likely etiology and clinical implications of this finding. PMID:27200163

  7. [FUNCTIONAL PLASTIC OF ANTERIOR ABDOMINAL WALL HERNIAS].

    PubMed

    Grubnik, V V; Parfentyeva, N D; Parfentyev, R S

    2015-07-01

    In order to improve the treatment efficacy of postoperative anterior abdominal wall hernias the method of plastic with restoration of anatomical and physiological properties of the muscles of the anterior abdominal wall was used. After the intervention by the improved method, regardless of the location of the hernia defect yielded promising results for the conservation of anterior abdominal wall muscle function in 75% of cases completely restored functional ability of muscles recti abdomini. PMID:26591212

  8. Incidental Anterior Cruciate Ligament Calcification: Case Report.

    PubMed

    Hayashi, Hisami; Fischer, Hans

    2016-03-01

    The calcification of knee ligaments is a finding noted only in a handful of case reports. The finding of an anterior cruciate ligament calcification has been reported once in the literature. Comparable studies involving the posterior cruciate ligament, medial collateral ligament and an ossicle within the anterior cruciate ligament are likewise discussed in reports of symptomatic patients. We report a case of incidentally discovered anterior cruciate ligament calcification. We discuss the likely etiology and clinical implications of this finding.

  9. Edge-on Galaxy

    NASA Technical Reports Server (NTRS)

    1999-01-01

    NASA's Hubble Space Telescope has imaged an unusual edge-on galaxy, revealing remarkable details of its warped dusty disc and showing how colliding galaxies trigger the birth of new stars.

    The image, taken by Hubble's Wide Field and Planetary Camera 2 (WFPC2), is online at http://heritage.stsci.edu and http://www.jpl.nasa.gov/images/wfpc. The camera was designed and built by NASA's Jet Propulsion Laboratory, Pasadena, Calif. During observations of the galaxy, the camera passed a milestone, taking its 100,000th image since shuttle astronauts installed it in Hubble in 1993.

    The dust and spiral arms of normal spiral galaxies, like our Milky Way, look flat when seen edge- on. The new image of the galaxy ESO 510-G13 shows an unusual twisted disc structure, first seen in ground-based photographs taken at the European Southern Observatory in Chile. ESO 510-G13 lies in the southern constellation Hydra, some 150 million light-years from Earth. Details of the galaxy's structure are visible because interstellar dust clouds that trace its disc are silhouetted from behind by light from the galaxy's bright, smooth central bulge.

    The strong warping of the disc indicates that ESO 510-G13 has recently collided with a nearby galaxy and is in the process of swallowing it. Gravitational forces distort galaxies as their stars, gas, and dust merge over millions of years. When the disturbances die out, ESO 510-G13 will be a single galaxy.

    The galaxy's outer regions, especially on the right side of the image, show dark dust and bright clouds of blue stars. This indicates that hot, young stars are forming in the twisted disc. Astronomers believe star formation may be triggered when galaxies collide and their interstellar clouds are compressed.

    The Hubble Heritage Team used WFPC2 to observe ESO 510-G13 in April 2001. Pictures obtained through blue, green, and red filters were combined to make this color-composite image, which emphasizes the contrast between the dusty

  10. Theory of edge detection.

    PubMed

    Marr, D; Hildreth, E

    1980-02-29

    A theory of edge detection is presented. The analysis proceeds in two parts. (1) Intensity changes, which occur in a natural image over a wide range of scales, are detected separately at different scales. An appropriate filter for this purpose at a given scale is found to be the second derivative of a Gaussian, and it is shown that, provided some simple conditions are satisfied, these primary filters need not be orientation-dependent. Thus, intensity changes at a given scale are best detected by finding the zero values of delta 2G(x,y)*I(x,y) for image I, where G(x,y) is a two-dimensional Gaussian distribution and delta 2 is the Laplacian. The intensity changes thus discovered in each of the channels are then represented by oriented primitives called zero-crossing segments, and evidence is given that this representation is complete. (2) Intensity changes in images arise from surface discontinuities or from reflectance or illumination boundaries, and these all have the property that they are spatially. Because of this, the zero-crossing segments from the different channels are not independent, and rules are deduced for combining them into a description of the image. This description is called the raw primal sketch. The theory explains several basic psychophysical findings, and the operation of forming oriented zero-crossing segments from the output of centre-surround delta 2G filters acting on the image forms the basis for a physiological model of simple cells (see Marr & Ullman 1979).

  11. Inner Synovial Membrane Footprint of the Anterior Elbow Capsule: An Arthroscopic Boundary

    PubMed Central

    Kamineni, Srinath; Bachoura, Abdo; Sasaki, Koichi; Reilly, Danielle; Harris, Kate N.; Sinai, Anthony; Deane, Andrew

    2015-01-01

    Introduction. The purpose of this study is to describe the inner synovial membrane (SM) of the anterior elbow capsule, both qualitatively and quantitatively. Materials and Methods. Twenty-two cadaveric human elbows were dissected and the distal humerus and SM attachments were digitized using a digitizer. The transepicondylar line (TEL) was used as the primary descriptor of various landmarks. The distance between the medial epicondyle and medial SM edge, SM apex overlying the coronoid fossa, the central SM nadir, and the apex of the SM insertion overlying the radial fossa and distance from the lateral epicondyle to lateral SM edge along the TEL were measured and further analyzed. Gender and side-to-side statistical comparisons were calculated. Results. The mean age of the subjects was 80.4 years, with six male and five female cadavers. The SM had a distinctive double arched attachment overlying the radial and coronoid fossae. No gender-based or side-to-side quantitative differences were noted. In 18 out of 22 specimens (81.8%), an infolding extension of the SM was observed overlying the medial aspect of the trochlea. The SM did not coincide with the outer fibrous attachment in any specimen. Conclusion. The humeral footprint of the synovial membrane of the anterior elbow capsule is more complex and not as capacious as commonly understood from the current literature. The synovial membrane nadir between the two anterior fossae may help to explain and hence preempt technical difficulties, a reduction in working arthroscopic volume in inflammatory and posttraumatic pathologies. This knowledge should allow the surgeon to approach this aspect of the anterior elbow compartment space with the confidence that detachment of this synovial attachment, to create working space, does not equate to breaching the capsule. Alternatively, stripping the synovial attachment from the anterior humerus does not constitute an anterior capsular release. PMID:26380112

  12. Anterior knee pain associated with an anterior superior patellar bony spur: a case report.

    PubMed

    Adekoya-Cole, T O; Enweluzo, G O; Akinmokun, O I; Olugbemi, O O

    2013-01-01

    Anterior knee pain is a common presentation in Orthopaedic out patient practice. However anterior superior patellar spur is an uncommon cause.This case presentation is to highlight an anterior superior patellar spur with quadriceps tendonitis. The patient is a 52 year old man who presented with a recurrent anterior knee pain. The radiographic study revealed an anterio-superior patellar spur. The patient had a depo steroid injection as an adjunct therapy to physiotherapy and has been pain free.

  13. Anomerization of Acrylated Glucose During Traveling Wave Ion Mobility Spectrometry

    NASA Astrophysics Data System (ADS)

    Chendo, Christophe; Moreira, Guillaume; Tintaru, Aura; Posocco, Paola; Laurini, Erik; Lefay, Catherine; Gigmes, Didier; Viel, Stéphane; Pricl, Sabrina; Charles, Laurence

    2015-09-01

    Anomerization of simple sugars in the liquid phase is known as an acid- and base-catalyzed process, which highly depends on solvent polarity. This reaction is reported here to occur in the gas phase, during traveling wave ion mobility spectrometry (TWIMS) experiments aimed at separating α- and β-anomers of penta-acrylated glucose generated as ammonium adducts in electrospray ionization. This compound was available in two samples prepared from glucose dissolved in solvents of different polarity, namely tetrahydrofuran (THF) and N,N-dimethylacetamide (DMAC), and analyzed by electrospray tandem mass spectrometry (ESI-MS/MS) as well as traveling wave ion mobility (ESI-TWIMS-MS). In MS/MS, an anchimerically-assisted process was found to be unique to the electrosprayed α-anomer, and was only observed for the THF sample. In ESI-TWIMS-MS, a signal was measured at the drift time expected for the α-anomer for both the THF and DMAC samples, in apparent contradiction to the MS/MS results, which indicated that the α-anomer was not present in the DMAC sample. However, MS/MS experiments performed after TWIMS separation revealed that ammonium adducts of the α-anomer produced from each sample, although exhibiting the same collision cross section, were clearly different. Indeed, while the α-anomer actually present in the THF sample was electrosprayed with the ammonium adducted at the C2 acrylate, its homologue only observed when the DMAC sample was subjected to TWIMS hold the adducted ammonium at the C1 acrylate. These findings were explained by a β/α inter-conversion upon injection in the TWIMS cell, as supported by theoretical calculation and dynamic molecular modeling.

  14. Hydrogen-free graphene edges

    NASA Astrophysics Data System (ADS)

    He, Kuang; Lee, Gun-Do; Robertson, Alex W.; Yoon, Euijoon; Warner, Jamie H.

    2014-01-01

    Graphene edges and their functionalization influence the electronic and magnetic properties of graphene nanoribbons. Theoretical calculations predict saturating graphene edges with hydrogen lower its energy and form a more stable structure. Despite the importance, experimental investigations of whether graphene edges are always hydrogen-terminated are limited. Here we study graphene edges produced by sputtering in vacuum and direct measurements of the C-C bond lengths at the edge show ~86% contraction relative to the bulk. Density functional theory reveals the contraction is attributed to the formation of a triple bond and the absence of hydrogen functionalization. Time-dependent images reveal temporary attachment of a single atom to the arm-chair C-C bond in a triangular configuration, causing expansion of the bond length, which then returns back to the contracted value once the extra atom moves on and the arm-chair edge is returned. Our results provide confirmation that non-functionalized graphene edges can exist in vacuum.

  15. Hydrogen-free graphene edges.

    PubMed

    He, Kuang; Lee, Gun-Do; Robertson, Alex W; Yoon, Euijoon; Warner, Jamie H

    2014-01-01

    Graphene edges and their functionalization influence the electronic and magnetic properties of graphene nanoribbons. Theoretical calculations predict saturating graphene edges with hydrogen lower its energy and form a more stable structure. Despite the importance, experimental investigations of whether graphene edges are always hydrogen-terminated are limited. Here we study graphene edges produced by sputtering in vacuum and direct measurements of the C-C bond lengths at the edge show ~86% contraction relative to the bulk. Density functional theory reveals the contraction is attributed to the formation of a triple bond and the absence of hydrogen functionalization. Time-dependent images reveal temporary attachment of a single atom to the arm-chair C-C bond in a triangular configuration, causing expansion of the bond length, which then returns back to the contracted value once the extra atom moves on and the arm-chair edge is returned. Our results provide confirmation that non-functionalized graphene edges can exist in vacuum.

  16. Photostabilization of polymeric materials by photoset acrylate coatings

    NASA Astrophysics Data System (ADS)

    Decker, C.; Zahouily, K.

    2002-01-01

    Different types of polymeric materials have been made more resistant to photodegradation by protecting their surface with a UV-cured coating containing a HALS radical scavenger and a phenyltriazine UV absorber. The tridimensional polymer network formed by photopolymerization of an aliphatic polyurethane-acrylate telechelic oligomer proved to be very resistant to accelerated weathering in the presence of these light stabilizers. The chemical modifications occurring upon QUV-ageing were monitored by infrared spectroscopy, a very sensitive technique well suited for quantitative analysis at an early stage of the photodegradation.

  17. Bond strength of denture teeth to acrylic bases.

    PubMed

    Cunningham, J L

    1993-10-01

    The literature relating to the determination of the bond strength of plastic denture teeth to acrylic resin denture material is reviewed. The papers are presented in chronological order with information on specimen preparation, batch sizes and methods of testing. The lack of uniformity in experimental techniques and the diverse range of products assessed makes recommendations for laboratory practice difficult to formulate. One consistent observation is that tooth surface contamination with wax decreases the bond strength between the teeth and the denture base material. A universal testing method needs to be formulated to replace the various techniques now employed.

  18. Reduction of airfoil trailing edge noise by trailing edge blowing

    NASA Astrophysics Data System (ADS)

    Gerhard, T.; Erbslöh, S.; Carolus, T.

    2014-06-01

    The paper deals with airfoil trailing edge noise and its reduction by trailing edge blowing. A Somers S834 airfoil section which originally was designed for small wind turbines is investigated. To mimic realistic Reynolds numbers the boundary layer is tripped on pressure and suction side. The chordwise position of the blowing slot is varied. The acoustic sources, i.e. the unsteady flow quantities in the turbulent boundary layer in the vicinity of the trailing edge, are quantified for the airfoil without and with trailing edge blowing by means of a large eddy simulation and complementary measurements. Eventually the far field airfoil noise is measured by a two-microphone filtering and correlation and a 40 microphone array technique. Both, LES-prediction and measurements showed that a suitable blowing jet on the airfoil suction side is able to reduce significantly the turbulence intensity and the induced surface pressure fluctuations in the trailing edge region. As a consequence, trailing edge noise associated with a spectral hump around 500 Hz could be reduced by 3 dB. For that a jet velocity of 50% of the free field velocity was sufficient. The most favourable slot position was at 90% chord length.

  19. Control of contamination of radon-daughters in the DEAP-3600 acrylic vessel

    NASA Astrophysics Data System (ADS)

    Jillings, Chris; DEAP Collaboration

    2013-08-01

    DEAP-3600 is a 3600kg single-phase liquid-argon dark matter detector under construction at SNOLAB with a sensitivity of 10-46cm2 for a 100 GeV WIMP. The argon is held an an acrylic vessel coated with wavelength-shifting 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). Acrylic was chosen because it is optically transparent at the shifted wavelength of 420 nm; an effective neutron shield; and physically strong. With perfect cleaning of the acrylic surface before data taking the irreducible background is that from bulk 210Pb activity that is near the surface. To achieve a background rate of 0.01 events in the 1000-kg fiducial volume per year of exposure, the allowed limit of Pb-210 in the bulk acrylic is 31 mBq/tonne (= 1.2 × 10-20g/g). We discuss how pure acrylic was procured and manufactured into a complete vessel paying particular attention to exposure to radon during all processes. In particular field work at the acrylic panel manufacturer, RPT Asia, and acrylic monomer supplier, Thai MMA Co. Ltd, in Thailand is described. The increased diffusion of radon during annealing the acrylic at 90C as well as techniques to mitigate against this are described.

  20. 40 CFR 721.10397 - Alkyl acrylate-polyfluoro methacrylate-poly(oxyalkylenediyl)-methacrylates (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Alkyl acrylate-polyfluoro methacrylate... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10397 Alkyl acrylate-polyfluoro... subject to reporting. (1) The chemical substances identified generically as alkyl...

  1. 40 CFR 721.10397 - Alkyl acrylate-polyfluoro methacrylate-poly(oxyalkylenediyl)-methacrylates (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Alkyl acrylate-polyfluoro methacrylate... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10397 Alkyl acrylate-polyfluoro... subject to reporting. (1) The chemical substances identified generically as alkyl...

  2. 40 CFR 721.10397 - Alkyl acrylate-polyfluoro methacrylate-poly(oxyalkylenediyl)-methacrylates (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Alkyl acrylate-polyfluoro methacrylate... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10397 Alkyl acrylate-polyfluoro... subject to reporting. (1) The chemical substances identified generically as alkyl...

  3. 40 CFR 721.10530 - Acrylate manufacture byproduct distillation residue (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... distillation residue (generic). 721.10530 Section 721.10530 Protection of Environment ENVIRONMENTAL PROTECTION... New Uses for Specific Chemical Substances § 721.10530 Acrylate manufacture byproduct distillation... substance is identified generically as acrylate manufacture byproduct distillation residue (PMN P-12-87)...

  4. 40 CFR 721.10530 - Acrylate manufacture byproduct distillation residue (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... distillation residue (generic). 721.10530 Section 721.10530 Protection of Environment ENVIRONMENTAL PROTECTION... New Uses for Specific Chemical Substances § 721.10530 Acrylate manufacture byproduct distillation... substance is identified generically as acrylate manufacture byproduct distillation residue (PMN P-12-87)...

  5. 21 CFR 177.1480 - Nitrile rubber modified acrylonitrile-methyl acrylate copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Nitrile rubber modified acrylonitrile-methyl... Nitrile rubber modified acrylonitrile-methyl acrylate copolymers. Nitrile rubber modified acrylonitrile... rubber modified acrylonitrile-methyl acrylate copolymers consist of basic copolymers produced by...

  6. 21 CFR 177.1480 - Nitrile rubber modified acrylonitrile-methyl acrylate copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Nitrile rubber modified acrylonitrile-methyl... Nitrile rubber modified acrylonitrile-methyl acrylate copolymers. Nitrile rubber modified acrylonitrile... rubber modified acrylonitrile-methyl acrylate copolymers consist of basic copolymers produced by...

  7. 21 CFR 177.1480 - Nitrile rubber modified acrylonitrile-methyl acrylate copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Nitrile rubber modified acrylonitrile-methyl... Nitrile rubber modified acrylonitrile-methyl acrylate copolymers. Nitrile rubber modified acrylonitrile... rubber modified acrylonitrile-methyl acrylate copolymers consist of basic copolymers produced by...

  8. 21 CFR 177.1480 - Nitrile rubber modified acrylonitrile-methyl acrylate copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Nitrile rubber modified acrylonitrile-methyl... Components of Single and Repeated Use Food Contact Surfaces § 177.1480 Nitrile rubber modified acrylonitrile-methyl acrylate copolymers. Nitrile rubber modified acrylonitrile-methyl acrylate copolymers...

  9. 21 CFR 177.1480 - Nitrile rubber modified acrylonitrile-methyl acrylate copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Nitrile rubber modified acrylonitrile-methyl... Nitrile rubber modified acrylonitrile-methyl acrylate copolymers. Nitrile rubber modified acrylonitrile... rubber modified acrylonitrile-methyl acrylate copolymers consist of basic copolymers produced by...

  10. Preparation and properties of acrylic resin coating modified by functional graphene oxide

    NASA Astrophysics Data System (ADS)

    Dong, Rui; Liu, Lili

    2016-04-01

    To improve the dispersion and the strength of filler-matrix interface in acrylic resin, the functional graphene oxide (FGO) was obtained by surface modification of graphene oxide (GO) by γ-methacryloxypropyl trimethoxysilane (KH-570) and then the acrylic nanocomposites containing different loadings of GO and FGO were prepared. The structure, morphology and dispersion/exfoliation of the FGO were characterized by XRD, FT-IR, Raman, XPS, SEM and TEM. The results demonstrated that the KH-570 was successfully grafted onto the surface of GO sheets. Furthermore, the corresponding thermal, mechanical and chemical resistance properties of the acrylic nanocomposites filled with the FGO were studied and compared with those of neat acrylic and GO/acrylic nanocomposites. The results revealed that the loading of FGO effectively enhanced various properties of acrylic resin. These findings confirmed that the dispersion and interfacial interaction were greatly improved by incorporation of FGO, which might be the result of covalent bonds between the FGO and the acrylic matrix. This work demonstrates an in situ polymerization method to construct a flexible interphase structure, strong interfacial interaction and good dispersion of FGO in acrylic nanocomposites, which can reinforce the polymer properties and be applied in research and industrial areas.

  11. 40 CFR 721.10389 - Styrene, copolymer with acrylic acid, salt with alkoxylated alkenylamine (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Styrene, copolymer with acrylic acid... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10389 Styrene, copolymer with acrylic... subject to reporting. (1) The chemical substance identified generically as styrene, copolymer with...

  12. 40 CFR 721.10389 - Styrene, copolymer with acrylic acid, salt with alkoxylated alkenylamine (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Styrene, copolymer with acrylic acid... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10389 Styrene, copolymer with acrylic... subject to reporting. (1) The chemical substance identified generically as styrene, copolymer with...

  13. Control of contamination of radon-daughters in the DEAP-3600 acrylic vessel

    SciTech Connect

    Jillings, Chris; Collaboration: DEAP Collaboration; and others

    2013-08-08

    DEAP-3600 is a 3600kg single-phase liquid-argon dark matter detector under construction at SNOLAB with a sensitivity of 10{sup −46}cm{sup 2} for a 100 GeV WIMP. The argon is held an an acrylic vessel coated with wavelength-shifting 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). Acrylic was chosen because it is optically transparent at the shifted wavelength of 420 nm; an effective neutron shield; and physically strong. With perfect cleaning of the acrylic surface before data taking the irreducible background is that from bulk {sup 210}Pb activity that is near the surface. To achieve a background rate of 0.01 events in the 1000-kg fiducial volume per year of exposure, the allowed limit of Pb-210 in the bulk acrylic is 31 mBq/tonne (= 1.2 × 10{sup −20}g/g). We discuss how pure acrylic was procured and manufactured into a complete vessel paying particular attention to exposure to radon during all processes. In particular field work at the acrylic panel manufacturer, RPT Asia, and acrylic monomer supplier, Thai MMA Co. Ltd, in Thailand is described. The increased diffusion of radon during annealing the acrylic at 90C as well as techniques to mitigate against this are described.

  14. 40 CFR 721.10389 - Styrene, copolymer with acrylic acid, salt with alkoxylated alkenylamine (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Styrene, copolymer with acrylic acid... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10389 Styrene, copolymer with acrylic... subject to reporting. (1) The chemical substance identified generically as styrene, copolymer with...

  15. Synthesis of Radiation Curable Palm Oil-Based Epoxy Acrylate: NMR and FTIR Spectroscopic Investigations.

    PubMed

    Salih, Ashraf M; Ahmad, Mansor Bin; Ibrahim, Nor Azowa; Dahlan, Khairul Zaman Hj Mohd; Tajau, Rida; Mahmood, Mohd Hilmi; Yunus, Wan Md Zin Wan

    2015-01-01

    Over the past few decades, there has been an increasing demand for bio-based polymers and resins in industrial applications, due to their potential lower cost and environmental impact compared with petroleum-based counterparts. The present research concerns the synthesis of epoxidized palm oil acrylate (EPOLA) from an epoxidized palm oil product (EPOP) as environmentally friendly material. EPOP was acrylated by acrylic acid via a ring opening reaction. The kinetics of the acrylation reaction were monitored throughout the reaction course and the acid value of the reaction mixture reached 10 mg KOH/g after 16 h, indicating the consumption of the acrylic acid. The obtained epoxy acrylate was investigated intensively by means of FTIR and NMR spectroscopy, and the results revealed that the ring opening reaction was completed successfully with an acrylation yield about 82%. The UV free radical polymerization of EPOLA was carried out using two types of photoinitiators. The radiation curing behavior was determined by following the conversion of the acrylate groups. The cross-linking density and the hardness of the cured EPOLA films were measured to evaluate the effect of the photoinitiator on the solid film characteristics, besides, the thermal and mechanical properties were also evaluated. PMID:26248072

  16. Anterior cervical hypertrichosis: a sporadic case

    PubMed Central

    Bostan, Sezen; Yaşar, Şirin; Serdar, Zehra Aşiran; Gizlenti, Sevda

    2016-01-01

    Anterior cervical hypertrichosis is a very rare form of primary localized hypertrichosis. It consists of a tuft of terminal hair on the anterior neck just above the laryngeal prominence. The etiology is still unknown. In this article, we reported a 15-year-old female patient who presented to our clinic with a complaint of hypertrichosis on the anterior aspect of the neck for the last five years. Her past medical history revealed no pathology except for vesicoureteral reflux. On the basis of clinical presentation, our patient was diagnosed with anterior cervical hypertrichosis and she was considered to be a sporadic case due to lack of other similar cases in familial history. To date, 33 patients with anterior cervical hypertrichosis have been reported. Anterior cervical hypertrichosis can be associated with other abnormalities, but it frequently presents as an isolated defect (70%). The association of vesicoureteral reflux and anterior cervical hypertrichosis which was observed in our patient might be coincidental. So far, no case of anterior cervical hypertrichosis associated with vesicoureteral reflux has been reported in the literature. PMID:27103865

  17. The acute aquatic toxicity of a series of acrylate and methacrylate esters

    SciTech Connect

    Staples, C.A.; McLaughlin, J.E.; Hamilton, J.D.

    1994-12-31

    Acute aquatic toxicity data for several acrylate and methacrylate esters were reviewed. Acrylates included acrylic acid, ethyl-, and butyl-acrylate. Methacrylates included methacrylic acid, methyl-, and butyl-methacrylate. Tests were 48 hr or 96 hr standard flow through (invertebrates and fish) assays (measured exposure concentrations). These data are currently used in a risk assessment of acrylate/methacrylate environmental safety. Algal growth (Selanastrum capricomutum) 96 hr EC{sub 50}s were 0.17 mg/L (NOEC < 0.13 mg/L) for acrylic acid, 11.0 mg/L (NOEC < 6.5 mg/L) for ethyl acrylate, and 5.2 mg/L (NOEC < 3.8 mg/L) for butyl acrylate. Invertebrate (Daphnia magna) 48 hr LC{sub 50}s were 95.0 mg/L (NOEC 23.0 mg/L) for acrylic acid, 7.9 mg/L (NOEC 3.4 mg/L) for ethyl acrylate, and 8.2 mg/L (NOEC 2.4 mg/L) for butyl acrylate. Rainbow trout (Oncorhynchus mykiss) 96 hr LC{sub 50}s were 27.0 mg/L (NOEC 6.3 mg/L) for acrylic acid, 4.6 mg/L (NOEC 0.78 mg/L) for ethyl acrylate, and 5.2 mg/L (NOEC 3.8 mg/L) for butyl acrylate. Algae 96 hr EC{sub 50}s were 0.59 mg/L (NOEC 0.38 mg/L) for methacrylic acid, 170.0 mg/L (NOEC 100.0 mg/L) for methyl methacrylate, and 130.0 mg/L for butyl methacrylate. Daphnia magna 48 hr LC{sub 50}s were > 130.0 mg/L (NOEC 130.0 mg/L) for methacrylic acid, 69.0 mg/L (NOEC 48.0 mg/L) for methyl methacrylate, and 32.0 mg/L (NOEC 23.0 mg/L) for butyl methacrylate. Trout 96 hr LC{sub 50}s were 85.0 mg/L (NOEC 12.0 mg/L) for methacrylic acid and > 79.0 mg/L (NOEC 40.0 mg/L) for methyl methacrylate. The fathead minnow (Pimephales promelas) 96 hr LC{sub 50} was 11.0 mg/L for butyl methacrylate.

  18. Fast tracking using edge histograms

    NASA Astrophysics Data System (ADS)

    Rokita, Przemyslaw

    1997-04-01

    This paper proposes a new algorithm for tracking objects and objects boundaries. This algorithm was developed and applied in a system used for compositing computer generated images and real world video sequences, but can be applied in general in all tracking systems where accuracy and high processing speed are required. The algorithm is based on analysis of histograms obtained by summing along chosen axles pixels of edge segmented images. Edge segmentation is done by spatial convolution using gradient operator. The advantage of such an approach is that it can be performed in real-time using available on the market hardware convolution filters. After edge extraction and histograms computation, respective positions of maximums in edge intensity histograms, in current and previous frame, are compared and matched. Obtained this way information about displacement of histograms maximums, can be directly converted into information about changes of target boundaries positions along chosen axles.

  19. Effect of Beverages on the Hardness and Tensile Bond Strength of Temporary Acrylic Soft Liners to Acrylic Resin Denture Base

    PubMed Central

    Safari, A; Vojdani, M; Mogharrabi, S; Iraji Nasrabadi, N; Derafshi, R

    2013-01-01

    Statement of Problem: Two potential problems commonly identified with a denture base incorporating a resilient liner are failure of the bond between acrylic resin and soft liner material, and loss of resiliency of the soft liner over time. Since patients may drink different beverages, it is important to evaluate their effects on physical properties of soft lining materials. Purpose: The objective of this in vitro study was to evaluate the effect of different beverages on the hardness of two temporary acrylic-based soft lining materials and their bond strength to the denture base resin. Materials and Method: For the hardness test; a total of 80 rectangular specimens (40mm×10mm×3mm) were fabricated from a heat-polymerized polymethylmethacrylate. Two commercially auto-polymerized acrylic resin-based resilient liners; Coe-Soft and Visco-gel were prepared according to the manufacturers’ instructions and applied on the specimens. For the tensile test, 160 cylindrical specimens (30mm×10mm) were prepared. The liners were added between specimens with a thickness of 3 mm. The specimens of both soft liners were divided into 4 groups (n=10) and immersed in distilled water as the control group, Coca-Cola, 8% and 50% ethanol. All groups were stored in separate containers at 37oC for 12 days. All beverages were changed daily. The hardness was determined using a Shore A durometer and tensile bond strength was determined in a ZwickRoell testing machine at a cross-head speed of 5mm/min. The results were analyzed using two-way ANOVA. Results: There was no significant interaction between the soft liners and the drinks for both hardness (p= 0.748) and bond strength (p= 0.902). There were statistically significant differences between all drinks for both hardness (p< 0.001) and bond strength (p< 0.05). Conclusion: Within the limitations of this study, it seems that drinking Coca-Cola and alcoholic beverages would not be potentially causing any problems for the temporary

  20. Fluoride Release from Hollow Silica Microsphere-Containing Dental Restorative Acrylate Resin.

    PubMed

    Ji, Yuqin; Gao, Jun; Yin, Hengbo; Wang, Aili; Jiang, Tingshun; Wu, Gang; Wu, Zhanao

    2015-05-01

    Hollow silica microspheres with mesoporous shells were prepared by the sacrificial template method. Hollow silica microsphere-containing acrylate resin-based dental restoration materials were prepared by using hollow silica microspheres as NaF reservoirs. Fluoride release performances from naked hollow silica microspheres, acrylate resin, and hollow silica microsphere-containing acrylate resin-based dental restorative materials in an artificial saliva were investigated. The results showed that hollow silica microsphere-containing acrylate resin-based dental restorative materials had higher cumulative fluoride release quantities and sustained fluoride release rates than traditional acrylate resin-based dental restorative materials. Fluoride release could be tuned by changing the mesoporous shell thickness of hollow silica microsphere.

  1. Plasma polymerization of acrylic acid onto polystyrene by cyclonic plasma at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Chang, Yi-Jan; Lin, Chin-Ho; Huang, Chun

    2016-01-01

    The cyclonic atmospheric-pressure plasma is developed for chamberless deposition of poly(acrylic acid) film from argon/acrylic acid mixtures. The photoemission plasma species in atmospheric-pressure plasma polymerization was identified by optical emission spectroscopy (OES). The OES diagnosis data and deposition results indicated that in glow discharge, the CH and C2 species resulted from low-energy electron-impact dissociation that creates deposition species, but the strong CO emission lines are related to nondeposition species. The acrylic acid flow rate is seen as the key factor affecting the film growth. The film surface analysis results indicate that a smooth, continuous, and uniform surface of poly(acrylic acid) films can be formed at a relatively low plasma power input. This study reveals the potential of chamberless film growth at atmospheric pressure for large-area deposition of poly(acrylic acid) films.

  2. The study of synthesis and photocuring behaviors of organic silicon modified methylacrylate and acrylate

    NASA Astrophysics Data System (ADS)

    Wang, Si-yuan; Zou, Ying-quan

    2012-03-01

    Ten different silicon-containing methyl acrylate and acrylate monomers were synthesized by the substitution reaction of chlorosilanes or chlorosiloxanes with 2-Hydroxyethyl methacrylate or 2-Hydroxyethyl acrylate. Using triethylamine as the catalytic agent, tetrahydrofuran as the solvent, pure products can be obtained with one-step reaction after reduced pressure distillation or column chromatography via controlling raw ratio and reaction time. In this study, one to four silicon contained methyl acrylate and acrylate monomers were synthesized with simple methd and high yield. Monomers' properties were characterized through IR, 1H-NMR, 13C-NMR and their viscosity and thermostability were also characterized. The polymers' have good performance on UV-curing and low surface energy.

  3. Influence of Sea Water Aging on the Mechanical Behaviour of Acrylic Matrix Composites

    NASA Astrophysics Data System (ADS)

    Davies, P.; Le Gac, P.-Y.; Le Gall, M.

    2016-07-01

    A new matrix resin was recently introduced for composite materials, based on acrylic resin chemistry allowing standard room temperature infusion techniques to be used to produce recyclable thermoplastic composites. This is a significant advance, particularly for more environmentally-friendly production of large marine structures such as boats. However, for such applications it is essential to demonstrate that composites produced with these resins resist sea water exposure in service. This paper presents results from a wet aging study of unreinforced acrylic and glass and carbon fibre reinforced acrylic composites. It is shown that the acrylic matrix resin is very stable in seawater, showing lower property losses after seawater aging than those of a commonly-used epoxy matrix resin. Carbon fibre reinforced acrylic also shows good property retention after aging, while reductions in glass fibre reinforced composite strengths suggest that specific glass fibre sizing may be required for optimum durability.

  4. Edge equilibrium code for tokamaks

    SciTech Connect

    Li, Xujing; Drozdov, Vladimir V.

    2014-01-15

    The edge equilibrium code (EEC) described in this paper is developed for simulations of the near edge plasma using the finite element method. It solves the Grad-Shafranov equation in toroidal coordinate and uses adaptive grids aligned with magnetic field lines. Hermite finite elements are chosen for the numerical scheme. A fast Newton scheme which is the same as implemented in the equilibrium and stability code (ESC) is applied here to adjust the grids.

  5. Acrylic Resin Molding Based Head Fixation Technique in Rodents.

    PubMed

    Roh, Mootaek; Lee, Kyungmin; Jang, Il-Sung; Suk, Kyoungho; Lee, Maan-Gee

    2016-01-12

    Head fixation is a technique of immobilizing animal's head by attaching a head-post on the skull for rigid clamping. Traditional head fixation requires surgical attachment of metallic frames on the skull. The attached frames are then clamped to a stationary platform resulting in immobilization of the head. However, metallic frames for head fixation have been technically difficult to design and implement in general laboratory environment. In this study, we provide a novel head fixation method. Using a custom-made head fixation bar, head mounter is constructed during implantation surgery. After the application of acrylic resin for affixing implants such as electrodes and cannula on the skull, additional resins applied on top of that to build a mold matching to the port of the fixation bar. The molded head mounter serves as a guide rails, investigators conveniently fixate the animal's head by inserting the head mounter into the port of the fixation bar. This method could be easily applicable if implantation surgery using dental acrylics is necessary and might be useful for laboratories that cannot easily fabricate CNC machined metal head-posts.

  6. Characteristics and mechanisms of acrylate polymer damage to maize seedlings.

    PubMed

    Chen, Xian; Mao, Xiaoyun; Lu, Qin; Liao, Zongwen; He, Zhenli

    2016-07-01

    Superabsorbent acrylate polymers (SAPs) have been widely used to maintain soil moisture in agricultural management, but they may cause damage to plants, and the mechanisms are not well understood. In this study, seed germination, soil pot culture, hydroponic experiments, and SAPs degradation were conducted to investigate damage characteristics and mechanisms associated with SAPs application. The Results showed that SAPs inhibited maize growth and altered root morphology (irregular and loose arrangement of cells and breakage of cortex parenchyma), and the inhibitory effects were enhanced at higher SAPs rates. After 1h SAP hydrogels treatment, root malondialdehyde (MDA) content was significantly increased, while superoxide dismutase (SOD) and catalase (CAT) content were significantly decreased. Hydroponics experiment indicated that root and shoot growth was inhibited at 2.5mgL(-1) acrylic acid (AA), and the inhibition was enhanced with increasing AA rates. This effect was exacerbated by the presence of Na(+) at a high concentration in the hydrogels. Release and degradation of AA were enhanced at higher soil moisture levels. A complete degradation of AA occurred between 15 and 20 days after incubation (DAI), but it took longer for Na(+) concentration to decrease to a safe level. These results indicate that high concentration of both AA and Na(+) present in the SAPs inhibits plant growth. The finding of this study may provide a guideline for appropriate application of SAPs in agriculture. PMID:27057990

  7. Direct fermentation route for the production of acrylic acid.

    PubMed

    Chu, Hun Su; Ahn, Jin-Ho; Yun, Jiae; Choi, In Suk; Nam, Tae-Wook; Cho, Kwang Myung

    2015-11-01

    There have been growing concerns regarding the limited fossil resources and global climate changes resulting from modern civilization. Currently, finding renewable alternatives to conventional petrochemical processes has become one of the major focus areas of the global chemical industry sector. Since over 4.2 million tons of acrylic acid (AA) is annually employed for the manufacture of various products via petrochemical processes, this chemical has been the target of efforts to replace the petrochemical route by ecofriendly processes. However, there has been limited success in developing an approach combining the biological production of 3-hydroxypropionic acid (3-HP) and its chemical conversion to AA. Here, we report the first direct fermentative route for producing 0.12 g/L of AA from glucose via 3-HP, 3-HP-CoA, and Acryloyl-CoA, leading to a strain of Escherichia coli capable of directly producing acrylic acid. This route was developed through extensive screening of key enzymes and designing a novel metabolic pathway for AA. PMID:26319589

  8. Color difference threshold determination for acrylic denture base resins.

    PubMed

    Ren, Jiabao; Lin, Hong; Huang, Qingmei; Liang, Qifan; Zheng, Gang

    2015-01-01

    This study aimed to set evaluation indicators, i.e., perceptibility and acceptability color difference thresholds, of color stability for acrylic denture base resins for a spectrophotometric assessing method, which offered an alternative to the visual method described in ISO 20795-1:2013. A total of 291 disk specimens 50±1 mm in diameter and 0.5±0.1 mm thick were prepared (ISO 20795-1:2013) and processed through radiation tests in an accelerated aging chamber (ISO 7491:2000) for increasing times of 0 to 42 hours. Color alterations were measured with a spectrophotometer and evaluated using the CIE L*a*b* colorimetric system. Color differences were calculated through the CIEDE2000 color difference formula. Thirty-two dental professionals without color vision deficiencies completed perceptibility and acceptability assessments under controlled conditions in vitro. An S-curve fitting procedure was used to analyze the 50:50% perceptibility and acceptability thresholds. Furthermore, perceptibility and acceptability against the differences of the three color attributes, lightness, chroma, and hue, were also investigated. According to the S-curve fitting procedure, the 50:50% perceptibility threshold was 1.71ΔE00 (r(2)=0.88) and the 50:50% acceptability threshold was 4.00 ΔE00 (r(2)=0.89). Within the limitations of this study, 1.71/4.00 ΔE00 could be used as perceptibility/acceptability thresholds for acrylic denture base resins.

  9. Graft copolymerization of acrylic acid onto polyamide fibers

    NASA Astrophysics Data System (ADS)

    Makhlouf, Chahira; Marais, Stéphane; Roudesli, Sadok

    2007-04-01

    The grafting of acrylic acid (AA) monomer (CH 2dbnd CH sbnd COOH) on polyamide 6.6 monofilaments (PA 6.6) using benzoyl peroxide (BPO) as initiator was carried out in order to enhance the hydrophilic nature of fibers. The grafting rate depends on the AA concentration, the BPO concentration, the time and the temperature of reaction. The best conditions for optimum rate of grafting were obtained with a AA concentration of 0.5 M, a BPO concentration of 0.03 M, a reaction temperature of T = 85 °C and a reaction time of 120 mn. The fiber surface has been investigated by many experimental techniques of characterization such as Fourier transform infrared spectroscopy (FTIR), calorimetric analysis (DSC), scanning electron microscopy (SEM), and contact angle measurements. The effect of grafting of acrylic acid onto PA 6.6 fibers on their moisture and mechanical resistances was analyzed from water sorption and elongation at break measurements. The analysis of the experimental data shows clearly the efficiency of the grafting reaction used, leading to a significant increase of the hydrophilic character of the PA 6.6 surface.

  10. Edge instabilities of topological superconductors

    NASA Astrophysics Data System (ADS)

    Hofmann, Johannes S.; Assaad, Fakher F.; Schnyder, Andreas P.

    2016-05-01

    Nodal topological superconductors display zero-energy Majorana flat bands at generic edges. The flatness of these edge bands, which is protected by time-reversal and translation symmetry, gives rise to an extensive ground-state degeneracy. Therefore, even arbitrarily weak interactions lead to an instability of the flat-band edge states towards time-reversal and translation-symmetry-broken phases, which lift the ground-state degeneracy. We examine the instabilities of the flat-band edge states of dx y-wave superconductors by performing a mean-field analysis in the Majorana basis of the edge states. The leading instabilities are Majorana mass terms, which correspond to coherent superpositions of particle-particle and particle-hole channels in the fermionic language. We find that attractive interactions induce three different mass terms. One is a coherent superposition of imaginary s -wave pairing and current order, and another combines a charge-density-wave and finite-momentum singlet pairing. Repulsive interactions, on the other hand, lead to ferromagnetism together with spin-triplet pairing at the edge. Our quantum Monte Carlo simulations confirm these findings and demonstrate that these instabilities occur even in the presence of strong quantum fluctuations. We discuss the implications of our results for experiments on cuprate high-temperature superconductors.

  11. Edge of polar cap patches

    NASA Astrophysics Data System (ADS)

    Hosokawa, K.; Taguchi, S.; Ogawa, Y.

    2016-04-01

    On the night of 4 December 2013, a sequence of polar cap patches was captured by an all-sky airglow imager (ASI) in Longyearbyen, Norway (78.1°N, 15.5°E). The 630.0 nm airglow images from the ASI of 4 second exposure time, oversampled the emission of natural lifetime (with quenching) of at least ˜30 sec, introduce no observational blurring effects. By using such high-quality ASI images, we succeeded in visualizing an asymmetry in the gradients between the leading/trailing edges of the patches in a 2-D fashion. The gradient in the leading edge was found to be 2-3 times steeper than that in the trailing edge. We also identified fingerlike structures, appearing only along the trailing edge of the patches, whose horizontal scale size ranged from 55 to 210 km. These fingers are considered to be manifestations of plasma structuring through the gradient-drift instability (GDI), which is known to occur only along the trailing edge of patches. That is, the current 2-D observations visualized, for the first time, how GDI stirs the patch plasma and such a mixing process makes the trailing edge more gradual. This result strongly implies a close connection between the GDI-driven plasma stirring and the asymmetry in the large-scale shape of patches and then suggests that the fingerlike structures can be used as markers to estimate the fine-scale structure in the plasma flow within patches.

  12. Anterior Shoulder Instability with Concomitant Superior Labrum from Anterior to Posterior (SLAP) Lesion Compared to Anterior Instability without SLAP Lesion

    PubMed Central

    Durban, Claire Marie C.; Kim, Je Kyun; Kim, Sae Hoon

    2016-01-01

    Background The aims of this study were to investigate the clinical characteristics of patients with combined anterior instability and superior labrum from anterior to posterior (SLAP) lesions, and to analyze the effect of concomitant SLAP repair on surgical outcomes. Methods We retrospectively reviewed patients who underwent arthroscopic stabilization for anterior shoulder instability between January 2004 and March 2013. A total of 120 patients were available for at least 1-year follow-up. Forty-four patients with reparable concomitant detached SLAP lesions (group I) underwent combined SLAP and anterior stabilization, and 76 patients without SLAP lesions (group II) underwent anterior stabilization alone. Patient characteristics, preoperative and postoperative pain scores, Rowe scores, and shoulder ranges of motion were compared between the 2 groups. Results Patients in group I had higher incidences of high-energy trauma (p = 0.03), worse preoperative pain visual analogue scale (VAS) (p = 0.02), and Rowe scores (p = 0.04). The postoperative pain VAS and Rowe scores improved equally in both groups without significant differences. Limitation in postoperative range of motion was similar between the groups (all p-value > 0.05). Conclusions Anterior instability with SLAP lesion may not be related to frequent episodes of dislocation but rather to a high-energy trauma. SLAP fixation with anterior stabilization procedures did not lead to poor functional outcomes if appropriate surgical techniques were followed. PMID:27247742

  13. Enzyme-catalyzed synthesis of saccharide acrylate monomers from nonedible biomass.

    PubMed

    Kloosterman, Wouter M J; Brouwer, Sander G M; Loos, Katja

    2014-08-01

    Various cellulase preparations were found to catalyze the transglycosidation between cotton linters and 2-hydroxyethyl acrylate. The conversion and enzyme activity were found to be optimal in reaction mixtures that contained 5 vol % of the acrylate. The structures of the products were revealed by using TLC and (1) H and (13) C NMR spectroscopy. The enzyme-catalyzed reaction resulted in two products. The minor product originated from transglycosidation to hemicellulose and was found to be 2-(β-xylosyloxy)-ethyl acrylate. The major product was identified as 2-(β-glucosyloxy)-ethyl acrylate and the yield of the product was 5 wt % based on the amount of consumed cellulose. Glycosidation products with oligosaccharide moieties could not be detected in the reaction mixture. This result can be explained by the hydrolytic activities of the used cellulase preparation. Cellulase from Trichoderma reesei was found to possess, in addition to endoglucanase activity, cellobiosidase and β-glucosidase activities. Five other cellulase preparations from different origins were tested as well for catalysis of oligosaccharide acrylate synthesis. For most cellulase preparations the major transglycosidation product appeared to be 2-(β-glucosyloxy)-ethyl acrylate. Nevertheless, the endo-β-(1,4)-glucanase from Trichoderma longibrachiatum was found to catalyze the synthesis of 2-(β-cellobiosyloxy)-ethyl acrylate. Unlike the other cellulase preparations, endo-β-(1,4)-glucanase from T. longibrachiatum showed no detectable β-glucosidase activity and therefore oligosaccharide acrylate monomers were not further hydrolyzed into the monosaccharide acrylate 2-(β-glucosyloxy)-ethyl acrylate. PMID:24866837

  14. The reactivity of selected acrylate esters toward glutathione and deoxyribonucleosides in vitro: structure-activity relationships.

    PubMed

    McCarthy, T J; Hayes, E P; Schwartz, C S; Witz, G

    1994-05-01

    Acrylate esters are alpha,beta-unsaturated esters used as plastic monomers whose toxicity may involve reaction with tissue nucleophiles via Michael addition. Structure-activity relationships for reactivity of selected esters with glutathione (GSH) and deoxyribonucleosides were investigated in the present studies. The esters investigated were methyl acrylate, methyl methacrylate, ethyl acrylate, ethyl methacrylate, butyl acrylate, butyl methacrylate, tetraethyleneglycol diacrylate, tetraethyleneglycol dimethacrylate, and ethyleneglycol dimethacrylate. To compare their reactivities toward GSH, esters were incubated for up to 1 hr at 37 degrees C and pH 7.4 with either GSH or red blood cells in phosphate-buffered saline followed by measurement of free thiol. In both systems acrylate electrophilic reactivity decreased with alpha-methyl substitution; however, the decrease in electrophilic reactivity was more evident in the cell-free system than in the red blood cell model. Increased alcohol chain length moderately affected the apparent second-order rate constant for the spontaneous reaction of acrylate esters with GSH, but did not affect potency relative to cellular GSH depletion. The apparent second-order rate constants of bifunctional esters are more than twice the rate constants of the much smaller monofunctional esters. Ethyl acrylate, a reactive acrylate ester based upon glutathione alkylation, has been designated a class 2B (suspect human) carcinogen by the International Agency for Research on Cancer. To detect possible DNA alkylation by acrylate esters in vitro, ethyl acrylate was incubated with deoxyribonucleosides for up to 24 hr at pH 6.7 or 7.4 and 37 degrees C or up to 8 hr and 50 degrees C. HPLC analysis revealed no detectable adduct formation.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Opacification of a hydrophilic acrylic intraocular lens with a hydrophobic surface after air injection in Descemet-stripping automated endothelial keratoplasty in a patient with Fuchs dystrophy.

    PubMed

    Mojzis, Peter; Studeny, Pavel; Werner, Liliana; Piñero, David P

    2016-03-01

    A 71-year-old woman with Fuchs endothelial dystrophy in the right eye had uneventful phacoemulsification cataract surgery with implantation of a single-piece intraocular lens (IOL) (CT47S) in January 2012. Because of corneal problems and vision loss, uneventful Descemet-stripping automated endothelial keratoplasty (DSAEK) was performed in May 2013. Four months later, a new corneal lamella (repeat DSAEK) was implanted with reinjection of an air bubble into the anterior chamber. Six months after the initial DSAEK, the patient complained of blurred vision. On examination, the cornea was transparent but the IOL presented opacification in the central area. The opacified IOL was explanted and analyzed by light microscopy, which showed the presence of thin granular deposits distributed in an overall round pattern that stained positive for calcium. The opacification of hydrophilic acrylic IOLs is a complication that can occur after uneventful endothelial keratoplasty, especially when rebubbling is necessary. PMID:27006326

  16. Investigation of fluorinated (Meth)acrylate monomers and macromonomers suitable for a hydroxy-containing acrylate monomer in UV nanoimprinting.

    PubMed

    Ito, Shunya; Kaneko, Shu; Yun, Cheol Min; Kobayashi, Kei; Nakagawa, Masaru

    2014-06-24

    We investigated reactive fluorinated (meth)acrylate monomers and macromonomers that caused segregation at the cured resin surface of a viscous hydroxy-containing monomer, glycerol 1,3-diglycerolate diacrylate (GDD), and decreased the demolding energy in ultraviolet (UV) nanoimprinting with spin-coated films under a condensable alternative chlorofluorocarbon gas atmosphere. The X-ray photoelectron spectroscopy and contact angle measurements used to determine the surface free energy suggested that a nonvolatile silicone-based methacrylate macromonomer with fluorinated alkyl groups segregated at the GDD-based cured resin surface and decreased the surface free energy, while fluorinated acrylate monomers hardly decreased the surface free energy because of their evaporation during the annealing of the spin-coated films. The average demolding energy of GDD-based cured resins with the macromonomer having fluorinated alkyl groups was smaller than that with the macromonomer having hydrocarbon alkyl groups. The fluorinated alkyl groups were responsible for decreasing the demolding energy rather than the polysiloxane main chains. We demonstrated that the GDD-based UV-curable resin with the fluorinated silicone-based macromonomer was suitable for step-and-repeat UV nanoimprinting with a bare silica mold, in addition to silica molds treated by chemical vapor surface modification with trifluoro-1,1,2,2-tetrahydropropyltrimethoxysilane (FAS3) and tridecafluoro-1,1,2,2-tetrahydrooctyltrimethoxysilane (FAS13). PMID:24892792

  17. Pharyngocutaneous fistula after anterior cervical spine surgery

    PubMed Central

    Sansur, Charles A.; Early, Stephen; Reibel, James

    2009-01-01

    Pharyngocutaneous fistulae are rare complications of anterior spine surgery occurring in less than 0.1% of all anterior surgery cases. We report a case of a 19 year old female who sustained a C6 burst fracture with complete quadriplegia. She was treated urgently with a C6 corpectomy with anterior cage and plating followed by posterior cervical stabilization at another institution. Post operatively she developed a pharyngocutaneous fistula that failed to heal despite several attempts of closure and esophageal exclusion with a Jpeg tube. The patient was eventually successfully treated with a three-stage procedure consisting of firstly a posterior approach to reinforce the posterior stabilization of the cervical spine that was felt to be inadequate, secondly an anterior approach with removal of all the anterior instrumentation followed by iliac crest bone graft and thirdly a superior based sternocleidomastoid flap that was interposed between the esophagus and the anterior cervical spine. The patient's fistula healed successfully. However, yet asymptomatic, the anterior iliac crest bone graft resorbed almost completely at 16 months follow up. In light of this complication, we discuss the surgical options for the treatment of pharyngocutaneous fistulae and the closure of this fistula using a superiorly based sternocleidomastoid muscle flap. PMID:19330360

  18. Chordal geometry determines the shape and extent of systolic anterior mitral motion: in vitro studies.

    PubMed

    Cape, E G; Simons, D; Jimoh, A; Weyman, A E; Yoganathan, A P; Levine, R A

    1989-05-01

    In patients with hypertrophic cardiomyopathy, the mitral valve moves anteriorly and assumes a unique shape, with mitral-septal contact centrally and preserved valve orifice area laterally. This shape is not clearly predicted by the Venturi mechanism, which stresses flow above the valve as opposed to changes intrinsic to the valve. On the other hand, it has been suggested that displacement of the papillary muscles anteriorly and toward one another, as observed in this disease, can promote anterior mitral valve motion and produce this unusual shape. The purpose of this in vitro study was to test the hypotheses that anterior motion of a membrane in a flow field can be generated by altering the distribution or effectiveness of chordal tension tethering the membrane, and that the shape achieved by this membrane depends on the geometry of chordal tension. Accordingly, a horizontal leaflet mounted in a flow chamber was attached by chords at its distal end to a series of upstream screws. Chordal tension could be varied by turning the screws or redirected by shifting the screws anteriorly. Anterior leaflet motion having the same unusual configuration seen in patients was reproduced by decreasing central chordal restraint while tension on the leaflet edges was maintained. Directing chordal tension anteriorly caused greater degrees of anterior motion at earlier stages in the release of chordal restraint; increased flow rate had a similar but less marked effect. These studies suggest that primary geometric alterations in the papillary-mitral apparatus can play an important role in determining the presence and geometry of systolic anterior mitral motion. The nature of these alterations suggests a role for anterior and inward papillary muscle displacement in promoting such motion. The geometric factors embodied in this model can explain many observed features of this motion not adequately explained by the Venturi effect, such as early systolic onset and the importance of a

  19. Anterior instability in the throwing shoulder.

    PubMed

    Savoie, Felix H; O'Brien, Michael J

    2014-06-01

    The disabled throwing shoulder is a multifactorial problem. Laxity of the glenohumeral joint is necessary to achieve a satisfactory velocity. Normal wear and tear with throwing may convert this normal amount of excessive translation into instability. Instability in the throwing athlete manifests itself in 2 forms: traumatic anterior instability that happens to occur in a throwing athlete and excessive anterior subluxation because of overuse that occurs in conjunction with the disabled throwing shoulder. In most cases, it is difficult to determine by physical examination or imaging how much laxity is too much; therefore, the managing physician should always err on the side of caution. A trial of rest and rehabilitation should always be attempted before any consideration of surgery. The multifactorial issues in the disabled throwing athlete should be corrected during this phase of treatment, including assessment and treatment of hip abnormalities, restoration of satisfactory core strength, correction of scapular dyskinesis, and an evaluation and correction of any biomechanical abnormalities in the throwing mechanism. Surgical management of anterior instability in the throwing shoulder depends on the mechanism of injury. The traumatic anterior instability patient is managed by acute surgical repair without a shift, utilizing mattress sutures to prevent suture chondromalacia on the humeral head or glenoid. The anterior laxity management centers on the posterior superior labrum, although occasionally the anterior labrum or capsule may be involved as well. Overall, symptomatic anterior instability is less common in the throwing shoulder. Jobe and colleagues are credited with the first successful technique for the correction of anterior instability in the throwing athlete, the anterior capsulolabral reconstruction by a subscapularis split. The success of this technique paved the way for the adoption of the current arthroscopic techniques that are utilized to correct

  20. Effect of chemical composition on corneal tissue response to photopolymerized materials comprising 2-hydroxyethyl methacrylate and acrylic acid.

    PubMed

    Lai, Jui-Yang

    2014-01-01

    The purpose of this work was to investigate the relationship between the feed composition of 2-hydroxyethyl methacrylate (HEMA)/acrylic acid (AAc) and hydrogel material compatibility towards ocular anterior segment tissues, particularly the corneal endothelium. The monomer solutions of HEMA and AAc were mixed at varying volume ratios of 92:0, 87:5, 82:10, 77:15, and 72:20, and were subjected to UV irradiation. Then, the 7-mm-diameter membrane implants made from photopolymerized materials were placed into the ocular anterior chamber for 4days and assessed by biomicroscopic examinations, corneal thickness measurements, and quantitative real-time reverse transcription polymerase chain reaction analyses. The poly(HEMA-co-AAc) implants prepared from the solution mixture containing 0-10vol.% AAc displayed good biocompatibility. However, with increasing volume ratio of AAc and HEMA from 15:77 to 20:72, the enhanced inflammatory response, decreased endothelial cell density, and increased ocular score and corneal thickness were observed, probably due to the influence of surface charge of copolymer membranes. On the other hand, the ionic pump function of corneal endothelium exposed to photopolymerized membranes was examined by analyzing the Na(+),K(+)-ATPase alpha 1 subunit (ATP1A1) expression level. The presence of the implants having higher amount of AAc incorporated in the copolymers (i.e., 15.1 to 24.7μmol) and zeta potential (i.e., -38.6 to -56.5mV) may lead to abnormal transmembrane transport. It is concluded that the chemical composition of HEMA/AAc has an important influence on the corneal tissue responses to polymeric biomaterials. PMID:24268266

  1. Trypan blue dye for anterior segment surgeries

    PubMed Central

    Jhanji, V; Chan, E; Das, S; Zhang, H; Vajpayee, R B

    2011-01-01

    Use of vital dyes in ophthalmic surgery has gained increased importance in the past few years. Trypan blue (TB) has been a popular choice among anterior segment surgeons mainly due to its safety, ease of availability, and remarkable ability to enable an easy surgery in difficult situations mostly related to visibility of the targeted tissue. It is being used in cataract surgery since nearly a decade and its utilization has been extended to other anterior segment surgeries like trabeculectomy and corneal transplantation. This review will discuss the techniques and outcome of TB dye-assisted anterior segment surgeries. PMID:21681214

  2. Quadriceps muscle contraction protects the anterior cruciate ligament during anterior tibial translation.

    PubMed

    Aune, A K; Cawley, P W; Ekeland, A

    1997-01-01

    The proposed skiing injury mechanism that suggests a quadriceps muscle contraction can contribute to anterior cruciate ligament rupture was biomechanically investigated. The effect of quadriceps muscle force on a knee specimen loaded to anterior cruciate ligament failure during anterior tibial translation was studied in a human cadaveric model. In both knees from six donors, average age 41 years (range, 31 to 65), the joint capsule and ligaments, except the anterior cruciate ligament, were cut. The quadriceps tendon, patella, patellar tendon, and menisci were left intact. One knee from each pair was randomly selected to undergo destructive testing of the anterior cruciate ligament by anterior tibial translation at a displacement rate of 30 mm/sec with a simultaneously applied 889 N quadriceps muscle force. The knee flexion during testing was 30 degrees. As a control, the contralateral knee was loaded correspondingly, but only 5 N of quadriceps muscle force was applied. The ultimate load for the knee to anterior cruciate ligament failure when tested with 889 N quadriceps muscle force was 22% +/- 18% higher than that of knees tested with 5 N of force. The linear stiffness increased by 43% +/- 30%. These results did not support the speculation that a quadriceps muscle contraction contributes to anterior cruciate ligament failure. In this model, the quadriceps muscle force protected the anterior cruciate ligament from injury during anterior tibial translation.

  3. How I do it: Anterior pull-through tympanoplasty for anterior eardrum perforations.

    PubMed

    Harris, Jeffrey P; Wong, Yu-Tung; Yang, Tzong-Hann; Miller, Mia

    2016-01-01

    Conclusions This technique is offered as a convenient and reliable method for cases with anterior TM perforation and inadequate anterior remnant. Objectives Chronic otitis media surgery is one of the most common procedures in otology. Anterior tympanic membrane (TM) perforation with inadequate anterior remnant is associated with higher rates of graft failure. It was the goal of this series to evaluate the anatomical and functional outcomes of a modified underlay myringoplasty technique-the anterior pull-through method. Materials and methods In a retrospective clinical study, 13 patients with anterior TM perforations with inadequate anterior remnants underwent tympanoplasty with anterior pull-through technique. The anterior tip of the temporalis fascia was pulled through and secured in a short incision lateral to the anterior part of the annulus. Data on graft take rate, pre-operative, and post-operative hearing status were analyzed. Results A graft success rate of 84.6% (11 out of 13) was achieved, without lateralization, blunting, atelectasia, or epithelial pearls. The air-bone gap was 21.5 ± 6.8 dB before intervention and 11.75 ± 5.7 dB after surgery (p = 0.003). PMID:26988908

  4. Flap-Edge Blowing Experiments

    NASA Technical Reports Server (NTRS)

    Gaeta, R. J.; Englar, R. J.; Ahuja, K. K.

    2003-01-01

    This Appendix documents the salient results from an effort to mitigate the so-called flap-edge noise generated at the split between a flap edge that is deployed and the undeployed flap. Utilizing a Coanda surface installed at the flap edge, steady blowing was used in an attempt to diminish the vortex strength resulting from the uneven lift distribution. The strength of this lifting vortex was augmented by steady blowing over the deployed flap. The test article for this study was the same 2D airfoil used in the steady blowing program reported earlier (also used in pulsed blowing tests, see Appendix G), however its trailing edge geometry was modified. An exact duplicate of the airfoil shape was made out of fiberglass with no flap, and in the clean configuration. It was attached to the existing airfoil to make an airfoil that has half of its flap deployed and half un-deployed. Figure 1 shows a schematic of the planform showing the two areas where steady blowing was introduced. The flap-edge blowing or the auxiliary blowing was in the direction normal to the freestream velocity vector. Slot heights for the blowing chambers were on the order of 0.0 14 inches.

  5. Edge-Aware BMA Filters.

    PubMed

    Guang Deng

    2016-01-01

    There has been continuous research in edge-aware filters which have found many applications in computer vision and image processing. In this paper, we propose a principled-approach for the development of edge-aware filters. The proposed approach is based on two well-established principles: 1) optimal parameter estimation and 2) Bayesian model averaging (BMA). Using this approach, we formulate the problem of filtering a pixel in a local pixel patch as an optimal estimation problem. Since a pixel belongs to multiple local patches, there are multiple estimates of the same pixel. We combine these estimates into a final estimate using BMA. We demonstrate the versatility of this approach by developing a family of BMA filters based on different settings of cost functions and log-likelihood and log-prior functions. We also present a new interpretation of the guided filter and develop a BMA guided filter which includes the guided filter as a special case. We show that BMA filters can produce similar smoothing results as those of the state-of-the-art edge-aware filters. Two BMA filters are computationally as efficient as the guided filter which is one of the fastest edge-aware filters. We also demonstrate that the BMA guided filter is better than the guided filter in preserving sharp edges. A new feature of the BMA guided filter is that the filtered image is similar to that produced by a clustering process.

  6. Facile Fabrication of Gradient Surface Based on (meth)acrylate Copolymer Films

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Yang, H.; Wen, X.-F.; Cheng, J.; Xiong, J.

    2016-08-01

    This paper describes a simple and economic approach for fabrication of surface wettability gradient on poly(butyl acrylate - methyl methacrylate) [P (BA-MMA)] and poly(butyl acrylate - methyl methacrylate - 2-hydroxyethyl methacrylate) [P (BA-MMA-HEMA)] films. The (meth)acrylate copolymer [including P (BA-MMA) and P (BA-MMA-HEMA)] films are hydrolyzed in an aqueous solution of NaOH and the transformation of surface chemical composition is achieved by hydrolysis in NaOH solution. The gradient wetting properties are generated based on different functional groups on the P (BA-MMA) and P (BA-MMA-HEMA) films. The effects of both the surface chemical and surface topography on wetting of the (meth)acrylate copolymer film are discussed. Surface chemical composition along the materials length is determined by XPS, and surface topography properties of the obtained gradient surfaces are analyzed by FESEM and AFM. Water contact angle system (WCAs) results show that the P (BA-MMA-HEMA) films provide a larger slope of the gradient wetting than P (BA-MMA). Moreover, this work demonstrates that the gradient concentration of chemical composition on the poly(meth) acrylate films is owing to the hydrolysis processes of ester group, and the hydrolysis reactions that have negligible influence on the surface morphology of the poly(meth) acrylate films coated on the glass slide. The gradient wettability surfaces may find broad applications in the field of polymer coating due to the compatibility of (meth) acrylate polymer.

  7. Antimicrobial activity of a quaternary ammonium methacryloxy silicate-containing acrylic resin: a randomised clinical trial

    PubMed Central

    Liu, Si-ying; Tonggu, Lige; Niu, Li-na; Gong, Shi-qiang; Fan, Bing; Wang, Liguo; Zhao, Ji-hong; Huang, Cui; Pashley, David H.; Tay, Franklin R.

    2016-01-01

    Quaternary ammonium methacryloxy silicate (QAMS)-containing acrylic resin demonstrated contact-killing antimicrobial ability in vitro after three months of water storage. The objective of the present double-blind randomised clinical trial was to determine the in vivo antimicrobial efficacy of QAMS-containing orthodontic acrylic by using custom-made removable retainers that were worn intraorally by 32 human subjects to create 48-hour multi-species plaque biofilms, using a split-mouth study design. Two control QAMS-free acrylic disks were inserted into the wells on one side of an orthodontic retainer, and two experimental QAMS-containing acrylic disks were inserted into the wells on the other side of the same retainer. After 48 hours, the disks were retrieved and examined for microbial vitality using confocal laser scanning microscopy. No harm to the oral mucosa or systemic health occurred. In the absence of carry-across effect and allocation bias (disks inserted in the left or right side of retainer), significant difference was identified between the percentage kill in the biovolume of QAMS-free control disks (3.73 ± 2.11%) and QAMS-containing experimental disks (33.94 ± 23.88%) retrieved from the subjects (P ≤ 0.001). The results validated that the QAMS-containing acrylic exhibits favourable antimicrobial activity against plaque biofilms in vivo. The QAMS-containing acrylic may also be used for fabricating removable acrylic dentures. PMID:26903314

  8. The photocatalytic enhancement of acrylic and PET solar water disinfection (SODIS) bottles.

    PubMed

    Carey, J M; Perez, T M; Arsiaga, E G; Loetscher, L H; Boyd, J E

    2011-01-01

    The solar water disinfection method (SODIS) was modified by the addition of a photocatalytic layer of titania on the interior surface of polyethylene terephthalate (PET) and acrylic bottles. Titania was solvent deposited on the interior of commercially available PET bottles, as well as bottles that were constructed from acrylic. Uncoated and titania-coated acrylic bottles removed 3,000,000-5,000,000 colony forming units per milliliter of K12 E. coli from 670 mL of contaminated water in 40 min of solar irradiance. After five hours of sunlight exposure, the concentration of 10 ppm methyl orange (a representative organic water contaminant), was reduced by 61% using the titania-coated acrylic bottles. The concentration of 87 ppb microcystin-LR (a representative algal toxin) was reduced by 70% after 7 hours of sunlight exposure in the titania-coated acrylic bottles. Acrylic is an effective alternative to PET for use in the SODIS method due to its greater UV transparency. The addition of titania to PET and acrylic bottles confers the ability to remove chemical contaminants in addition to inactivating microbiological contaminants.

  9. Effect of thermal cycling and disinfection on microhardness of acrylic resin denture base.

    PubMed

    Goiato, Marcelo Coelho; Dos Santos, Daniela Micheline; Baptista, Gabriella Trunckle; Moreno, Amália; Andreotti, Agda Marobo; Dekon, Stéfan Fiuza de Carvalho

    2013-04-01

    The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins.

  10. An ORMOSIL-containing orthodontic acrylic resin with concomitant improvements in antimicrobial and fracture toughness properties.

    PubMed

    Gong, Shi-qiang; Epasinghe, Jeevani; Rueggeberg, Frederick A; Niu, Li-na; Mettenberg, Donald; Yiu, Cynthia K Y; Blizzard, John D; Wu, Christine D; Mao, Jing; Drisko, Connie L; Pashley, David H; Tay, Franklin R

    2012-01-01

    Global increase in patients seeking orthodontic treatment creates a demand for the use of acrylic resins in removable appliances and retainers. Orthodontic removable appliance wearers have a higher risk of oral infections that are caused by the formation of bacterial and fungal biofilms on the appliance surface. Here, we present the synthetic route for an antibacterial and antifungal organically-modified silicate (ORMOSIL) that has multiple methacryloloxy functionalities attached to a siloxane backbone (quaternary ammonium methacryloxy silicate, or QAMS). By dissolving the water-insoluble, rubbery ORMOSIL in methyl methacrylate, QAMS may be copolymerized with polymethyl methacrylate, and covalently incorporated in the pressure-processed acrylic resin. The latter demonstrated a predominantly contact-killing effect on Streptococcus mutans ATCC 36558 and Actinomyces naselundii ATCC 12104 biofilms, while inhibiting adhesion of Candida albicans ATCC 90028 on the acrylic surface. Apart from its favorable antimicrobial activities, QAMS-containing acrylic resins exhibited decreased water wettability and improved toughness, without adversely affecting the flexural strength and modulus, water sorption and solubility, when compared with QAMS-free acrylic resin. The covalently bound, antimicrobial orthodontic acrylic resin with improved toughness represents advancement over other experimental antimicrobial acrylic resin formulations, in its potential to simultaneously prevent oral infections during appliance wear, and improve the fracture resistance of those appliances.

  11. An ORMOSIL-Containing Orthodontic Acrylic Resin with Concomitant Improvements in Antimicrobial and Fracture Toughness Properties

    PubMed Central

    Rueggeberg, Frederick A.; Niu, Li-na; Mettenberg, Donald; Yiu, Cynthia K. Y.; Blizzard, John D.; Wu, Christine D.; Mao, Jing; Drisko, Connie L.; Pashley, David H.; Tay, Franklin R.

    2012-01-01

    Global increase in patients seeking orthodontic treatment creates a demand for the use of acrylic resins in removable appliances and retainers. Orthodontic removable appliance wearers have a higher risk of oral infections that are caused by the formation of bacterial and fungal biofilms on the appliance surface. Here, we present the synthetic route for an antibacterial and antifungal organically-modified silicate (ORMOSIL) that has multiple methacryloloxy functionalities attached to a siloxane backbone (quaternary ammonium methacryloxy silicate, or QAMS). By dissolving the water-insoluble, rubbery ORMOSIL in methyl methacrylate, QAMS may be copolymerized with polymethyl methacrylate, and covalently incorporated in the pressure-processed acrylic resin. The latter demonstrated a predominantly contact-killing effect on Streptococcus mutans ATCC 36558 and Actinomyces naselundii ATCC 12104 biofilms, while inhibiting adhesion of Candida albicans ATCC 90028 on the acrylic surface. Apart from its favorable antimicrobial activities, QAMS-containing acrylic resins exhibited decreased water wettability and improved toughness, without adversely affecting the flexural strength and modulus, water sorption and solubility, when compared with QAMS-free acrylic resin. The covalently bound, antimicrobial orthodontic acrylic resin with improved toughness represents advancement over other experimental antimicrobial acrylic resin formulations, in its potential to simultaneously prevent oral infections during appliance wear, and improve the fracture resistance of those appliances. PMID:22870322

  12. Base-Mediated Stereospecific Synthesis of Aryloxy and Amino substituted Ethyl Acrylates

    PubMed Central

    Namjoshi, Ojas A.; Verma, Ranjit; Lorenz, Michael; Tiruveedhula, V. V. N. Phani Babu; Monte, Aaron; Bertz, Steven H.

    2011-01-01

    The stereospecific synthesis of aryloxy and amino substituted E- and Z-ethyl-3-acrylates is of interest because of their potential in the polymer industry and in medicinal chemistry. During work on a copper-catalyzed cross-coupling reaction of E- and Z-ethyl-3-iodo-acrylates with phenols and N-heterocycles, we discovered a very simple (non-metallic) method for the stereospecific synthesis of aryloxy and amino substituted acrylates. To study this long standing problem on the stereoselectivity of aryloxy and amino substituted acrylates, a series of O- and N-substituted nucleophiles was allowed to react with E- and Z-ethyl-3-iodo-acrylates. Screening of different bases indicated that DABCO (1,4-diazabicyclo[2.2.2]octane) afforded successful conversion of E- and Z- ethyl-3-iodoacrylates into aryloxy and amino substituted ethyl acrylates in a stereospecific manner. Herein are the details of this DABCO-mediated stereospecific synthesis of aryloxy and amino substituted E- or Z-acrylates. PMID:22073965

  13. Antimicrobial activity of a quaternary ammonium methacryloxy silicate-containing acrylic resin: a randomised clinical trial.

    PubMed

    Liu, Si-ying; Tonggu, Lige; Niu, Li-na; Gong, Shi-qiang; Fan, Bing; Wang, Liguo; Zhao, Ji-hong; Huang, Cui; Pashley, David H; Tay, Franklin R

    2016-02-23

    Quaternary ammonium methacryloxy silicate (QAMS)-containing acrylic resin demonstrated contact-killing antimicrobial ability in vitro after three months of water storage. The objective of the present double-blind randomised clinical trial was to determine the in vivo antimicrobial efficacy of QAMS-containing orthodontic acrylic by using custom-made removable retainers that were worn intraorally by 32 human subjects to create 48-hour multi-species plaque biofilms, using a split-mouth study design. Two control QAMS-free acrylic disks were inserted into the wells on one side of an orthodontic retainer, and two experimental QAMS-containing acrylic disks were inserted into the wells on the other side of the same retainer. After 48 hours, the disks were retrieved and examined for microbial vitality using confocal laser scanning microscopy. No harm to the oral mucosa or systemic health occurred. In the absence of carry-across effect and allocation bias (disks inserted in the left or right side of retainer), significant difference was identified between the percentage kill in the biovolume of QAMS-free control disks (3.73 ± 2.11%) and QAMS-containing experimental disks (33.94 ± 23.88%) retrieved from the subjects (P ≤ 0.001). The results validated that the QAMS-containing acrylic exhibits favourable antimicrobial activity against plaque biofilms in vivo. The QAMS-containing acrylic may also be used for fabricating removable acrylic dentures.

  14. Gel polymer electrolytes based on nanofibrous polyacrylonitrile–acrylate for lithium batteries

    SciTech Connect

    Kim, Dul-Sun; Woo, Jang Chang; Youk, Ji Ho; Manuel, James; Ahn, Jou-Hyeon

    2014-10-15

    Graphical abstract: - Highlights: • Nanofibrous polyacrylonitrile–acrylate membranes were prepared by electrospinning. • Trimethylolpropane triacrylate was used as a crosslinking agent of fibers. • The GPE based on PAN–acrylate (1/0.5) showed good electrochemical properties. - Abstract: Nanofibrous membranes for gel polymer electrolytes (GPEs) were prepared by electrospinning a mixture of polyacrylonitrile (PAN) and trimethylolpropane triacrylate (TMPTA) at weight ratios of 1/0.5 and 1/1. TMPTA is used to achieve crosslinking of fibers thereby improving mechanical strength. The average fiber diameters increased with increasing TMPTA concentration and the mechanical strength was also improved due to the enhanced crosslinking of fibers. GPEs based on electrospun membranes were prepared by soaking them in a liquid electrolyte of 1 M LiPF{sub 6} in ethylene carbonate (EC)/dimethyl carbonate (DMC) (1:1, v/v). The electrolyte uptake and ionic conductivity of GPEs based on PAN and PAN–acrylate (weight ratio; 1/1 and 1/0.5) were investigated. Ionic conductivity of GPEs based on PAN–acrylate was the highest for PAN/acrylate (1/0.5) due to the proper swelling of fibers and good affinity with liquid electrolyte. Both GPEs based on PAN and PAN–acrylate membranes show good oxidation stability, >5.0 V vs. Li/Li{sup +}. Cells with GPEs based on PAN–acrylate (1/0.5) showed remarkable cycle performance with high initial discharge capacity and low capacity fading.

  15. Revision Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Wilde, Jeffrey; Bedi, Asheesh; Altchek, David W.

    2014-01-01

    Context: Reconstruction of the anterior cruciate ligament (ACL) is one of the most common surgical procedures, with more than 200,000 ACL tears occurring annually. Although primary ACL reconstruction is a successful operation, success rates still range from 75% to 97%. Consequently, several thousand revision ACL reconstructions are performed annually and are unfortunately associated with inferior clinical outcomes when compared with primary reconstructions. Evidence Acquisition: Data were obtained from peer-reviewed literature through a search of the PubMed database (1988-2013) as well as from textbook chapters and surgical technique papers. Study Design: Clinical review. Level of Evidence: Level 4. Results: The clinical outcomes after revision ACL reconstruction are largely based on level IV case series. Much of the existing literature is heterogenous with regard to patient populations, primary and revision surgical techniques, concomitant ligamentous injuries, and additional procedures performed at the time of the revision, which limits generalizability. Nevertheless, there is a general consensus that the outcomes for revision ACL reconstruction are inferior to primary reconstruction. Conclusion: Excellent results can be achieved with regard to graft stability, return to play, and functional knee instability but are generally inferior to primary ACL reconstruction. A staged approach with autograft reconstruction is recommended in any circumstance in which a single-stage approach results in suboptimal graft selection, tunnel position, graft fixation, or biological milieu for tendon-bone healing. Strength-of-Recommendation Taxonomy (SORT): Good results may still be achieved with regard to graft stability, return to play, and functional knee instability, but results are generally inferior to primary ACL reconstruction: Level B. PMID:25364483

  16. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials

    PubMed Central

    Heidari, Bijan; Firouz, Farnaz; Izadi, Alireza; Ahmadvand, Shahbaz

    2015-01-01

    Objectives: Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a common clinical occurrence, which often develops in the midline of the denture base. This study aimed to evaluate the efficacy of cold-cure and heat-cure acrylic resins, reinforced with glass fibers, polyethylene fibers, and metal wire for denture base repair. Materials and Methods: Ninety specimens were prepared and allocated to nine groups. Ten specimens were considered as controls, and 80 were divided into 8 experimental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was divided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were subjected to a 3-point bending test, and the flexural strength was calculated. Results: The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement. Conclusion: Repairing denture base with heat cure acrylic resin, reinforced with glass fibers increases the flexural strength of denture base. PMID:26877726

  17. Image recovery from edge primitives

    NASA Technical Reports Server (NTRS)

    Alter-Gartenberg, Rachel; Huck, Friedrich O.; Narayanswamy, Ramkumar

    1990-01-01

    A method for extracting edge primitives from Mach-band patterns is presented together with a method for recovering image representations of features outlined by the edge boundaries. The accuracy, stability, and resolution of these representations are assessed. Since these representations are most commonly used in characterizing targets, this method of low-level processing offers new opportunities for computer vision and high data-compressing coding. Two bandpass filters are considered, the spatially invariant Laplacian of Gaussian filter and spatially variant intensity-dependent spatial (IDS) summation. It is shown that the recovery from the IDS bandpass data is particularly advantageous in applications for which robustness to local and temporal variations in illumination is important. It is concluded that the edge primitives extracted from bandpassed images can be an efficient way to store, transmit, and represent images.

  18. [Acrylic resin reinforcement with metallic and nonmetallic inserts].

    PubMed

    Preoteasa, Elena; Murariu, Cătălina Măgureanu; Ionescu, Ecaterina; Preoteasa, Cristina Teodora

    2007-01-01

    In the current use of acrylic resin for removable dentures and orthodontic treatments we are frequently facing the fact of base fracture. The repairing of this, determine most of the time, discomfort of the patient, by excluding the prosthetic device, affecting the treatment, loosing patient's time, doctor's time, implying the dental laboratory and extra expenses. The causes of fractures are many, from clinical cases with some specific anatomic and functional particularities, or parafunctional, to the incorrect designing, manufacturing or wearing of the prosthetic part, being connected with the materials characteristics. The consequences and costs of these fractures are leading to unsatisfying results in some of the clinical cases, in presence of parafunctions like bruxism or clenching and specifically for the new types of prosthetic rehabilitation, on natural teeth or implants. PMID:17983190

  19. Chain Transfer of Vegetable Oil Macromonomers in Acrylic Solution Copolymerization

    SciTech Connect

    Black, Micah; Messman, Jamie M; Rawlins, James

    2011-01-01

    Use of vegetable oil macromonomers (VOMMs) as comonomers in emulsion polymerization enables good film coalescence without the addition of solvents that constitute volatile organic compounds (VOCs). VOMMs are derived from renewable resources and offer the potential of post-application crosslinking via auto-oxidation. However, chain transfer reactions of VOMMs with initiator and/or polymer radicals during emulsion polymerization reduce the amount of allylic hydrogen atoms available for primary auto-oxidation during drying. Vegetable oils and derivatives were reacted in combination with butyl acrylate and methyl methacrylate via solution polymerization. The copolymerization was monitored using in situ infrared spectroscopy to determine the extent of chain transfer. 1H NMR spectroscopy was used to determine the loci of chain transfer and the molecular weight characteristics of the polymers were characterized by SEC. Solution polymerization was utilized to minimize temperature fluctuations and maintain polymer solubility during the initial characterization.

  20. Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses

    PubMed Central

    Dai, Yunhai; Huang, Yusen; Liu, Ting; Xie, Lixin

    2014-01-01

    Two three-piece hydrophobic acrylic intraocular lenses (IOLs) were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to their opacified IOLs. In addition to light microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, confocal laser scanning microscopy was used for the first time to observe the explanted IOLs. The clinical aspect seemed to correspond to the phenomenon of surface light scattering, while laboratory analyses showed dense glistenings in the central layer of the IOL optic, which had no change next to the surface. Further studies on these phenomena are needed. PMID:25005210

  1. Spectral filters based on ethylene/acrylic acid copolymer ionomers

    SciTech Connect

    Riley, M.O.; Walkup, C.M.; Hagen, W.F.; Jessop, E.S.

    1988-09-01

    We are investigating the possibility of utilizing ionomers as inexpensive, easily replaced optical filters for applications in large fusion lasers as well as high average power solid state lasers. To this end we have synthesized a number of other derivatives of the ethylene/acrylic acid (EAA) copolymer system. Specifically, we prepared several ionomers at nominal 3 wt. % metal ion concentration, including Fe(III), Co(II), Ni(II), Cu(II), and Ce(III), by reacting aqueous solutions of metal acetates or nitrates with aqueous ammonia dispersions (1) of EAA as described previously. The products were compression molded into thin optically clear films under the above-described conditions. A gel was formed in a similar reaction with samarium (III) nitrate. Accordingly, the samarium ionomer was synthesized by a melt phase reaction between the EAA resin and the metal nitrate. 6 refs., 2 figs., 2 tabs.

  2. Cerenkov Light Collection With an Acrylic Wavelength Shifting Plate

    NASA Astrophysics Data System (ADS)

    Carl, Michael; Reinhold, Joerg

    2003-04-01

    Collection of Cerenkov light with an acrylic wavelength shifting plate was investigated. The test setup consisted of a plate, 30cm long, 10cm wide, and 1 cm thick placed behind a 5 cm deep stack of aerogel tiles. On the long ends the wavelength shifter was read out by two 5 inch photomultipliers. The response of the system to pions and protons at 1.2 GeV/c momentum was measured at the KEK PS facility in Japan. On average 6 photoelectrons radiated from the aerogel could be detected. The results will be presented and possible designs for future detectors will be discussed with emphasis on particle identification for high momentum spectrometers at an upgraded Jefferson Lab facility.

  3. Dynamic relationships of the mandibular anterior segment.

    PubMed

    Braun, S; Hnat, W P

    1997-05-01

    The hyperbolic cosine function is shown to be an accurate representation of the form of the mandibular anterior teeth from the canine/first premolar contact on one side around the perimeter to the opposite side (r = 0.951). On the basis of this mathematical function, the changes in canine width, anterior segment depth, arch perimeter, and their related incisor angular alterations are forecastable. This knowledge will allow the clinician to predict the effects on various aspects of the anterior segment arch form as one or more of these variables are altered without resorting to trial and error or performing a wax-up. For example, the clinician can predict the change in the anterior segment arch depth and incisor angulation that would occur with alterations in canine width.

  4. Swelling behaviors of porous lignin based poly (acrylic acid).

    PubMed

    Ma, Yanli; Sun, Yajie; Fu, Yujie; Fang, Guizhen; Yan, Xingru; Guo, Zhanhu

    2016-11-01

    Supramolecular cross-linked porous lignin based poly (acrylic acid) [LBPAA] was lab-synthesized by copolymerizing lignin grafted N, N'-methylene-bisacrylamide (LM) and acrylic acid. LBPAA successfully acted as a water retention agent with salt resistance and biodegradation for agricultural applications. Lignin was found to improve its swelling behaviors with higher water retention, fast swelling and de-swelling rates. The salt tolerance was stronger in the case of LBPAA (60 PAA/40 LM) [60 wt% PAA/40 wt% LM], i.e., 145.79 g·g(-1) higher than PAA at 0.09 mM KCl solution. The effect of ion charges on the LBPAA swelling ratio was greater than that of ionic radius. The weight loss of LBPAA (60 PAA/40 LM) was 5.47%, 4.96%, and 4.56% in the soil of Tangshan, Harbin, and Sian, respectively. The soil moisture content and clay content were observed to decrease gradually with increasing the burial time. The biodegradation test of LBPAA (60 PAA/40 LM) composite exhibited different bacterial colony forming units (CFU), the soil of Tangshan was 2.0 × 10(3) CFU·g(-1) soil, 7.0 × 10(3) CFU·g(-1) soil for Harbin, and 6.10 × 10(4) CFU·g(-1) soil for Sian. However, the organic matter contents in the soils did not have significant changes (Tangshan 6.21 mg·g(-1), Harbin 0.61 mg·g(-1), and Sian 0.405 mg·g(-1)). PMID:27587327

  5. Radiation-induced grafting of acrylic acid onto polyethylene filaments

    NASA Astrophysics Data System (ADS)

    Kaji, K.; Okada, T.; Sakurada, I.

    Radiation-induced grafting of acrylic acid onto high density polyethylene (PE) filaments was carried out in order to raise softening temperature and impart flame retardance and hydrophilic properties. Mutual γ-irradiation method was employed for the grafting in a mixture of acrylic acid (AA), ethylene dichloride and water containing a small amount of ferrous ammonium sulfate. The rate of grafting was very low at room temperature. On the other hand, large percent grafts were obtained when the grafting was performed at an elevated temperature. Activation energy for the initial rate of grafting was found to be 17 {kcal}/{mol} between 20 and 60°C and 10 {kcal}/{mol} between 60 and 80°C. Original PE filament begins to shrink at 70°C, show maximum shrinkage of 50% at 130°C and then breaks off at 136°C. When a 34% AA graft is converted to metallic salt such as sodium and calcium, the graft filament retains its filament form even above 300°C and gives maximum shrinkage of 15%. Burning tests by a wire-netting basket method indicate that graft filaments and its metallic salts do not form melting drops upon burning and are self-extinguishing. Original PE filament shows no moisture absorption, however, that of AA-grafted PE increases with increasing graft percent. The sodium salt of 15% graft shows the same level of moisture regain as cotton. The AA-grafted PE filament and its metallic salts can be dyed with cationic dyes even at 1% graft. Tensile properties of PE filament is impaired neither by grafting nor by conversion to metallic salts.

  6. The rising trend in allergic contact dermatitis to acrylic nail products.

    PubMed

    Le, Quynh; Cahill, Jennifer; Palmer-Le, Amanda; Nixon, Rosemary

    2015-08-01

    Shellac is a newly available type of long-wearing nail polish, which is becoming increasingly popular. We describe four cases of allergic contact dermatitis (ACD) to acrylates found in Shellac nail products, involving three beauticians and one consumer who purchased the product over the internet. Increasing use of these new acrylic nail products means that dermatologists need to be aware of the possibility of ACD occurring. Testing with hydroxyethyl methacrylate alone, which is included in the Australian Baseline Series, is adequate for screening for acrylate allergy. PMID:25752641

  7. Impression techniques for multiple implants: a photoelastic analysis. Part II: comparison of four acrylic resins.

    PubMed

    Lopes-Júnior, Itamar; de Lima Lucas, Barbara; Gomide, Henner Alberto; Gomes, Vanderlei Luiz

    2013-10-01

    Four commercial brands of chemically activated acrylic resin were compared through photoelastic analysis. Photoelastic resin blocks were made with 2 implants placed parallel to each other and 2 square transfer copings splinted. Both transfers were splinted with chemically activated acrylic resin: Dencrilay, Duralay I, Duralay II, and GC. Data were analyzed by 2-way analysis of variance and Tukey test (P < .05). Statistically significant differences were found among the 3 brands of chemically activated acrylic resin. Dencrilay showed greater dimensional alteration. Duralay I and GC are recommended for the transfer of the position of the multi-implants.

  8. Erlotinib-related bilateral anterior uveitis

    PubMed Central

    Ali, Kashif; Kumar, Indu; Usman-Saeed, Muniba; Usman Saeed, Muhammad

    2011-01-01

    The authors report the case of a 68-year-old woman with secondary adenocarcinoma of the lungs from an unknown primary. Erlotinib was started which produced symptoms suggestive of uveitis. Erlotinib was stopped and restarted a month later at a lower dose, which resulted in severe bilateral anterior uveitis. The uveitis settled after stopping erlotinib and treatment with topical steroids and cycloplegics. To the best of the authors’ knowledge, this is the first case of erlotinib-related anterior uveitis. PMID:22694887

  9. Rehabilitation of anterior cruciate ligament injuries.

    PubMed

    Halling, A H; Howard, M E; Cawley, P W

    1993-04-01

    Rehabilitation of the anterior cruciate ligament absent or reconstructed knee is becoming a true artform. Accelerated, but controlled rehabilitation, is becoming more commonplace. Scientific-based data along with clinical experiences are the basis of the rehabilitation guidelines brought forth in this article. Anterior cruciate ligament strain and implications for exercise, continuous passive motion, proprioceptive exercise, and the role of knee bracing are all discussed in relation to the overall rehabilitation program.

  10. Anterior capsular defect with acute anterior subcapsular cataract in herpetic keratouveitis

    PubMed Central

    Arora, Tarun; Sharma, Namrata; Arora, Supriya; Titiyal, Jeewan S

    2014-01-01

    A 20-year-old man presented with a recurrent episode of herpetic keratouveitis in his right eye. The patient was treated with oral acyclovir and topical steroids. One week later the patient reported a sudden diminution of vision. Slitlamp biomicroscopy revealed the presence of a central anterior capsular defect and anterior subcapsular cataract. Dosage of steroids was temporarily increased and progression of cataract monitored. Subsequently, the anterior chamber reaction decreased and steroids were tapered. PMID:25228677

  11. Anterior Eye Imaging with Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Huang, David; Li, Yan; Tang, Maolong

    The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.

  12. Measuring the mutual diffusion coefficient for dodecyl acrylate in low molecular weight poly(dodecyl acrylate) with laser line deflection (Wiener's Method) and the fluorescence of pyrene.

    PubMed

    Antrim, Daniel; Bunton, Patrick; Lewis, Lydia Lee; Zoltowski, Brian D; Pojman, John A

    2005-06-16

    Diffusion of small molecules into glassy polymers is quite complicated and almost always non-Fickian. Little work has been done with the diffusion of low molecular weight polymers that are liquids at room temperature (such as poly(dodecyl acrylate)) into their miscible monomers. We have studied three molecular weights under 20 000 to determine if poly(dodecyl acrylate) diffusion into dodecyl acrylate could be treated with Fick's law and if so to determine the values of the diffusion coefficients. We compare two methods for measuring the diffusion of dodecyl acrylate into poly(dodecyl acrylate): We used laser line deflection (Wiener's method) and improved upon the method from published reports. We also used the dependence of pyrene's fluorescence on the viscosity to measure the concentration distribution, and thus to extract the diffusion coefficient. After an initial relaxation period, diffusion in all cases followed Fick's law with a single concentration-independent diffusion coefficient. Comparison of the diffusion coefficients obtained by both methods yielded the same order of magnitude for the diffusion coefficients (10(-7) cm2/s) and showed the same trend in the dependence on the average molecular weight of the polymer (a decrease in the diffusion coefficient with an increase in the molecular weight).

  13. Shape-dependent canny edge detector

    NASA Astrophysics Data System (ADS)

    Panetta, Karen A.; Agaian, Sos S.; Nercessian, Shahan C.; Almunstashri, Ali A.

    2011-08-01

    Edges characterize the boundaries of objects in images and are informative structural cues for computer vision and target/object detection and recognition systems. The Canny edge detector is widely regarded as the edge detection standard. It is fairly adaptable to different environments, as its parametric nature attempts to tailor the detection of edges based on image-dependent characteristics or the particular requirements of a given implementation. Though it has been used in a myriad of image processing tasks, the Canny edge detector is still vulnerable to edge losses, localization errors, and noise sensitivity. These issues are largely due to the key tradeoff made in the scale and size of the edge detection filters used by the algorithm. Small-scaled filters are sensitive to edges but also to noise, whereas large-scaled filters are robust to noise but could filter out fine details. In this paper, novel edge detection kernel generalizations and a shape-dependent edge detector are introduced to alleviate these shortcomings. While most standard edge detection algorithms are based on convolving the input image with fixed size square kernels, this paper will illustrate the benefits of different filter sizes, and more importantly, different kernel shapes for edge detection. Moreover, new edge fusion methods are introduced to more effectively combine the individual edge responses. Existing edge detectors, including the Canny edge detector, can be obtained from the generalized edge detector by specifying corresponding parameters and kernel shapes. The proposed representations and edge detector have been qualitatively and quantitatively evaluated on several different types of image data. Computer simulations demonstrate that nonsquare kernel approaches can outperform square kernel approaches such as Canny, Sobel, Prewitt, Roberts, and others, providing better tradeoffs between noise rejection, accurate edge localization, and resolution. Where possible, Pratt's figure of

  14. The Problem of the Edge.

    ERIC Educational Resources Information Center

    Faatz, Judith A.

    1998-01-01

    Describes a field study in a local ecosystem which allows high school students to investigate the edge effect, where a meadow and a forest meet. Students measure soil moisture content, soil temperature, air temperature, relative humidity, wind intensity, and illumination level. Teachers can help students apply their findings to understand problems…

  15. Development of edge effects around experimental ecosystem hotspots is affected by edge density and matrix type

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Ecological edge effects are sensitive to landscape context. In particular, edge effects can be altered by matrix type and by the presence of other nearby edges. We experimentally altered patch configurations in an African savanna to determine how edge density and matrix type influence edge effect de...

  16. Edge absorption and circular photogalvanic effect in 2D topological insulator edges

    NASA Astrophysics Data System (ADS)

    Entin, M. V.; Magarill, L. I.

    2016-06-01

    The electron absorption on the edge states and the edge photocurrent of a 2D topological insulator (TI) are studied. We consider the optical transitions within linear edge branches of the energy spectrum. The interaction with impurities is taken into account. The circular polarization is found to produce the edge photocurrent, the direction of which is determined by light polarization and edge orientation.

  17. Synthesis and characterization of amylose grafted poly(acrylic acid) and its application in ammonia adsorption.

    PubMed

    Chen, Qing; Yu, Haojie; Wang, Li; Abdin, Zain-Ul; Yang, Xinpeng; Wang, Junhua; Zhou, Weidong; Zhang, Hongtao; Chen, Xiao

    2016-11-20

    Amylose grafted poly(acrylic acid) (Am-g-PAA) was synthesized by graft copolymerization of amylose with acrylic acid. The structure of Am-g-PAA was confirmed by (1)H NMR and FT-IR spectra. The morphology, crystallinity and thermal properties of amylose and Am-g-PAA were investigated by SEM, XRD and TGA, respectively. The highest degree of substitution (DS) of carboxyl group was 1.96 which was obtained after reacted for 1h at 60°C. Acrylic acid to anhydroglucose mole ratio for DS was 19.81. It was found that a large number of carboxyl groups were grafted on the backbone of amylose. It was also found that ammonia adsorption capacity of amylose increased by grafting poly(acrylic acid) on the backbone of amylose. PMID:27561514

  18. Dielectric studies of alkyl acrylates with primary alcohols using time domain reflectometry

    NASA Astrophysics Data System (ADS)

    Dharmalingam, K.; Ramachandran, K.; Sivagurunathan, P.; Prabhakar Undre, B.; Khirade, P. W.; Mehrotra, S. C.

    Binary polar-polar liquid mixtures of alkyl acrylates (methyl acrylate, ethyl acrylate and butyl acrylate) with primary alcohols (propan-1-ol, butan-1-ol and hexan-1-ol) were subjected to dielectric studies at 303 K for different concentrations using time domain reflectometry (TDR) over the frequency range from 10 MHz to 10 GHz. Static permittivity (ɛ0) dielectric constant at high frequency (ɛ∞) and relaxation time (τ) were found through dielectric measurements for different concentrations of each system. The Bruggeman dielectric factor, Kirkwood correlation factor and the excess inverse relaxation time were determined and discussed to yield information on the molecular interactions of the systems. Deviations from the linearity of various models suggest molecular association through hydrogen bonding between the -OH group of alcohols and C=O group of esters. The results also show a dependence of dielectric parameters on the alkyl chain length of both the alcohols and esters.

  19. Biobased composites from thermoplastic polyurethane elastomer and cross-linked acrylated-epoxidized soybean oil

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Soybean oil is an important sustainable material. Crosslinked acrylated epoxidized soybean oil (AESO) is brittle without flexibility and the incorporation of thermoplastic polyurethane improves its toughness for industrial applications. The hydrophilic functional groups from both oil and polyurethan...

  20. Removal of methyl acrylate by ceramic-packed biotrickling filter and their response to bacterial community.

    PubMed

    Wu, Hao; Yin, Zhenhao; Quan, Yue; Fang, Yingyu; Yin, Chengri

    2016-06-01

    Methyl acrylate is a widely used raw chemical materials and it is toxic in humans. In order to treat the methyl acrylate waste gas, a 3-layer BTF packed with ceramic particles and immobilized with activated sludge was set up. The BTF exhibited excellent removal efficiency that no methyl acrylate could be detected when EBRT was larger than 266s and inlet concentration was lower than 0.19g/m(3). The 1st layer performed the best at fixed inlet concentration of 0.42g/m(3). PCR combined with DGGE was performed to detect the differences in different layers of the BTF. Phylum Proteobacteria (e.g. α-, β-, γ-, δ-) was predominantly represented in the bacterial community, followed by Actinobacteria and Firmicutes. Desulfovibrio gigas, Variovorax paradoxus, Dokdonella koreensis, Pseudoxanthomonas suwonensis, Azorhizobium caulinodans, Hyphomicrobium denitrificans, Hyphomicrobium sp. and Comamonas testosteroni formed the bacteria community to treat methyl acrylate waste gas in the BTF. PMID:26970927

  1. Novel (meth)acrylate monomers for ultrarapid polymerization and enhanced polymer properties

    SciTech Connect

    Beckel, E. R.; Berchtold, K. A.; Nie, J.; Lu, H.; Stansbury, J. W.; Bowman, C. N.

    2002-01-01

    Ultraviolet light is known to be one of the most efficient methods to initiatc polymeric reactions in the presence of a photonitiator. Photopolymerizations are advantageous because the chemistry of the materials can be tailored to design liquid monomers for ultrarapid polymerization into a solid polymer material. One way to achieve rapid photopolymerizations is to utilize multifunctional (meth)acrylate monomers. which form highly crosslinked polymers; however, these monomers typically do not achieve complete functional group conversion. Recently, Decker et al. developed novel monovinyl acrylate monomers that display polyriicrization kinetics that rival those of multifunctional acrylate monomers. These novel acrylate monomers incorporate secondary functionalities and end groups such as carbonates, carbamates, cyclic carbonates and oxazolidone which promote the increased polymerization kinetics of these monomers. In addition to thc polynierization kinetics, these novel monovinyl monomers form crosslinked polymers, which are characterized by having high strength and high flexibility. Unfortunately, the exact mechanism or mechanisms responsible for the polymerization kinetics and crosslinking are not well understood.

  2. Synthesis and self-assembly of poly(3-hexylthiophene)-block-poly(acrylic acid)

    SciTech Connect

    Li, Zicheng; Ono, Robert J.; Wu, Zong-Quan; Bielawski, Christopher W.

    2011-01-01

    A modular and convenient synthesis of ethynyl end functionalized poly(3-hexylthiophene) in high purity is reported; this material facilitated access to poly(3-hexylthiophene)-block-poly(acrylic acid) which self-assembled into hierarchical structures.

  3. Optical properties of UV transmitting acrylics for use in a heavy water Cerenkov detector

    SciTech Connect

    Zwinkels, J.C.; Davidson, W.F.; Dodd, C. )

    1990-08-01

    The absorption, refraction, and scattering properties of several UV transmitting acrylics have been investigated over the wavelength range 300--700 nm using a combination of near-normal incidence regular transmittance and reflectance and diffuse-only reflectance measurements, followed by a Fresnel and a Kubelka-Munk analysis. The samples were evaluated in the as-cast and thermoformed forms, and both before and after an accelerated aging procedure. The results show significant differences in the optical behavior of the various acrylics in the UV region and stress the importance of carefully characterizing acrylic from different sources for each intended use. In our case, acrylic is the proposed material for a heavy water containment vessel for the detection of solar neutrinos. The significance of our findings to the overall performance of this Cerenkov detector, known as the Sudbury neutrino observatory detector, is discussed.

  4. Optical properties of UV transmitting acrylics for use in a heavy water Cerenkov detector.

    PubMed

    Zwinkels, J C; Davidson, W F; Dodd, C X

    1990-08-01

    The absorption, refraction, and scattering properties of several UV transmitting acrylics have been investigated over the wavelength range 300-700 nm using a combination of near-normal incidence regular transmittance and reflectance and diffuse-only reflectance measurements, followed by a Fresnel and a Kubelka-Munk analysis. The samples were evaluated in the as-cast and thermoformed forms, and both before and after an accelerated aging procedure. The results show significant differences in the optical behavior of the various acrylics in the UV region and stress the importance of carefully characterizing acrylic from different sources for each intended use. In our case, acrylic is the proposed material for a heavy water containment vessel for the detection of solar neutrinos. The significance of our findings to the overall performance of this Cerenkov detector, known as the Sudbury neutrino observatory detector, is discussed.

  5. Systolic anterior motion of the mitral valve after mitral valve repair: a method of prevention.

    PubMed

    Sternik, Leonid; Zehr, Kenton J

    2005-01-01

    Factors predisposing patients to systolic anterior motion of the mitral valve (SAM) with left ventricular outflow tract (LVOT) obstruction after mitral valve repair are the presence of a myxomatous mitral valve with redundant leaflets, a nondilated hyperdynamic left ventricle, and a short distance between the mitral valve coaptation point and the ventricular septum after repair. From December 1999 through March 2000, we used our surgical method in 6 patients with severely myxomatous regurgitant mitral valves who were at risk of developing SAM. Leaflets were markedly redundant in all 6. Left ventricular function was hyperdynamic in 4 patients and normal in 2. Triangular or quadrangular resection of the midportion of the posterior leaflet and posterior band annuloplasty were performed. To prevent SAM and LVOT obstruction, extra, posteriorly directed, mid-posterior-leaflet secondary chordae tendineae, which would otherwise have been resected, were transferred to the underside of the middle of the mid-anterior leaflet with a small piece of associated valve as an anchoring pledget. This kept the redundant anterior leaflet edge, which extended below the coaptation point, away from the LVOT No post-repair SAM or LVOT obstruction was observed on intraoperative or discharge echocardiography. All patients had no or trivial residual mitral regurgitation. We conclude that extra chordae tendineae, when available, can be used in mitral valve repair to tether the redundant anterior leaflet and thus prevent it from flipping into the LVOT. This will theoretically prevent SAM and LVOT obstruction in patients with risk factors for SAM.

  6. Vascularized middle turbinate flap for the endoscopic endonasal reconstruction of the anterior olfactory groove.

    PubMed

    Tamura, Ryota; Toda, Masahiro; Kohno, Maya; Watanabe, Yoshihiro; Ozawa, Hiroyuki; Tomita, Toshiki; Ogawa, Kaoru; Yoshida, Kazunari

    2016-04-01

    A vascularized middle turbinate flap (MTF) might be useful in the repair of lesions in the anterior olfactory groove. The sizes of the MTF and inferior turbinate flap (ITF) and these distances up to the frontal base were analyzed by computed tomography (CT) using a picture archiving and communication system (PACS) in 20 patients. The minimum flap measurement to reconstruct the skull base was defined as the distance from the basal plate to the medial slope or lateral slope edge of the MTF and the ITF on the coronal view. Next, we reviewed clinical data from three patients with dural deficits who underwent endoscopic vascularized MTF reconstruction. The distance to the frontal base from the ITF was significantly longer than that from the MTF. The minimum length of the MTF measured by coronal CT was similar to the distance to the frontal base. In contrast, the minimum length of the ITF was shorter than the distance to the frontal base. These results suggest that the MTF might be superior to the ITF for coverage of the anterior frontal base. Three patients who underwent MTF reconstruction for a defect in the anterior olfactory groove had good outcomes and no complications. The MTF is a good option for reconstruction of defects in the anterior part of the olfactory groove. PMID:26681333

  7. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

    PubMed Central

    Jang, Dae-Eun; Lee, Ji-Young; Jang, Hyun-Seon; Lee, Jang-Jae

    2015-01-01

    PURPOSE The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed. PMID:26330974

  8. In vitro cytotoxicity of self-curing acrylic resins of different colors

    PubMed Central

    Retamoso, Luciana Borges; da Cunha, Taís de Morais Alves; Pithon, Matheus Melo; dos Santos, Rogério Lacerda; Martins, Fernanda Otaviano; Romanos, Maria Teresa Villela; Tanaka, Orlando Motohiro

    2014-01-01

    Objective The aim of this study was to assess the in vitro cytotoxicity of acrylic resins of different colors over time. Methods Specimens were divided into 4 groups (n = 6) according to the color of the acrylic resin (Orto Class, Clássico, Campinas, São Paulo, Brazil): Group 1: clear acrylic resin; group 2: pink acrylic resin; group 3: blue acrylic resin and group 4: green acrylic resin. All specimens were fabricated according to the mass manipulation technique and submitted to mechanical polishing protocol. The control was performed with an amalgam specimen (C+), a glass specimen (C-) and cell control (CC). Specimens were immersed in Minimum Eagle's Medium (MEM) and incubated for 24 h at 37ºC. The extracts from the experimental material were filtered and mixed with L929 fibroblast. Cytotoxicity was evaluated at 4 different times, 24, 48, 72 and 168 h. After contact, cells were incubated for 24 h and added to 100 µ of 0.01% neutral red dye. The cells were incubated for 3 h for pigment incorporation and fixed. Cells viability was determined by a spectroscopic (BioTek, Winooski, Vermont, USA) with a 492-nm wavelength λ=492 nm). Results There were no statistical differences between the experimental groups and the CC and C- groups. Conclusion Clear, pink, blue and green self-curing acrylic resins fabricated by means of the mass manipulation technique and mechanically polished are not cytotoxic. Neither the pigment added to the self-curing acrylic resin nor the factor of time influenced the cytotoxicity of the material. PMID:25279523

  9. Testing of gloves for permeability to UV-curable acrylate coatings

    SciTech Connect

    Huggins, R.; Levy, N.; Pruitt, P.M.

    1987-07-01

    The handling of UV-curable acrylate formulations used in the coating of optical fiber requires protective measures to prevent contact dermatitis and/or allergic dermatitis. To characterize the permeability of various glove materials to a UV-curable acrylate coating, a study was undertaken using a modification of a standard ASTM permeability test, which demonstrated that nitrile rubber gloves provided the best protection of those glove materials tested.

  10. Mucoadhesive acrylated block copolymers micelles for the delivery of hydrophobic drugs.

    PubMed

    Eshel-Green, Tal; Bianco-Peled, Havazelet

    2016-03-01

    Blockpolymer micelles having acrylated end groups were fabricated for the development of mucoadhesive drug loaded vehicle. The critical micelle concentration (CMC) of Pluronic(®) F127 modified with acrylate end groups (F127DA) was found to be similar to that of the unmodified Pluronic(®) F127 (F127). Small angle X-ray scattering verified existence of micelles with an inner core of 4.9±0.2 and 5.5±0.3 for F127 and F127DA respectively. Indomethacin, a hydrophobic drug, was incorporated into the micelles using the thin-film hydration method. In vitro drug release assay demonstrated that the micelles sustained the release of the drug in comparison with free drug in solution. Several methods were used for mucoadhesion evaluation. Viscosity profiling was performed by shear rate sweep experiment of hydrated commercial mucin, F127 or F127DA, and combination of both mucin and a copolymer. Elevated viscosity was achieved for acrylated micelles with mucin compared to mixtures of non-acrylated micelles with mucin. The mucoadhesivity of the acrylated micelles was further characterized using nuclear magnetic resonance (NMR); data affirmed the Michael type addition reaction occurred between acrylates on the micelles corona and thiols present in the mucin. SAXS scattering data further showed a modification in the scattering of F127DA micelles with the addition of pig gastric mucin. Cryo-transmission electron microscopy (cryo-TEM) and dynamic light scattering (DLS) data detected increase in the aggregates size while using acrylated micelles enhance mucoadhesion. Thus acrylated F127DA micelles were found to be mucoadhesive, and a suitable and preferred candidate for micellar drug delivery to mucosal surfaces. PMID:26700232

  11. Silver hollow optical fibers with acrylic silicone resin coating as buffer layer for sturdy structure

    NASA Astrophysics Data System (ADS)

    Iwai, Katsumasa; Takaku, Hiroyuki; Miyagi, Mitsunobu; Shi, Yi-Wei; Zhu, Xiao-Song; Matsuura, Yuji

    2016-03-01

    For sturdy silver hollow optical fibers, acrylic silicone resin is newly used as a buffer layer between an inner silver layer and a silica capillary. This acrylic silicone resin film prevents the glass surface from chemical and mechanical micro damages during silver plating process, which deteriorate mechanical strength of the hollow fibers. In addition, it keeps high adhesion of the silver layer with the glass surface. We discuss improvement of mechanical strength of the hollow glass fibers without deterioration of optical properties.

  12. Structure and properties of binary polystyrene-epoxy acrylate oligomer mixtures irradiated by electron beams

    SciTech Connect

    Lomonosova, N.V.

    1995-03-01

    The change in the structure of oriented polymer-oligomer systems based on polystyrene (PS) with M > 10{sup 6} and epoxy acrylate oligomers (aliphatic and aromatic) under irradiation by accelerated electrons was studied using birefringence, isometric heating, IR dichroism, and thermooptical analysis. Mechanical properties of these systems were investigated. It was found that, by adding aliphatic epoxy acrylate to PS and further irradiating this mixture, one can obtain both isotropic and oriented composites with higher strengths, elasticity moduli, and glass transition temperatures.

  13. Structure-activity relationships in the hydrolysis of acrylate and methacrylate esters by carboxylesterase in vitro.

    PubMed

    McCarthy, T J; Witz, G

    1997-01-15

    Acrylate esters are important chemicals in the plastics industry, whose toxicity is theorized to involve alkylation of critical cellular nucleophiles via the Michael addition. Carboxylesterase-mediated hydrolysis of acrylates may be a detoxification mechanism as the unsaturated acid produced is not electrophilic under physiological conditions. Using purified porcine liver carboxylesterase, the enzymatic hydrolysis of several acrylate esters was characterized to determine Km and Vmax values for each ester. The Km (microM) and Vmax (nmol/min) values observed for ethyl acrylate were 134 +/- 16 (S.D.) and 8.9 +/- 2.0, respectively. While the Km for ethyl methacrylate was not significantly different, the Vmax 5.5 +/- 2.5, was significantly lower compared with the corresponding value for ethyl acrylate. The Km and Vmax for butyl acrylate were 33.3 +/- 8.5 microM and 1.49 +/- 0.83 nmol/min, respectively, and the corresponding values for its alpha-methyl analog were not significantly different. The Km and Vmax for tetraethyleneglycol dimethacrylate were 39 +/- 15 microM and 2.9 +/- 1.0 nmol/min, respectively. The Vmax for ethyleneglycol dimethacrylate, 6.9 +/- 2.4 nmol/min, was significantly higher than that of the larger bifunctional ester tetraethyleneglycol dimethacrylate, but the Km was not significantly different. These results indicate that alpha-methyl substitution appears to have a minor effect in the enzymatic hydrolysis of acrylates, and suggest that the relative toxicity of acrylates is not due to differences in carboxylesterase-mediated hydrolysis.

  14. Continuous process of preparation of n-butyl(meth)acrylate by esterification of (meth)acrylic acid by butanol on thermostable sulfo-cation exchanger

    SciTech Connect

    Zheleznaya, L.L.; Karakhanov, R.A.; Lunin, A.F.; Magadov, R.S.; Meshcheryakov, S.V.; Mkrtychan, V.R.; Fomin, V.A.

    1987-11-10

    The authors propose an effective thermostable sulfo-cation exchanger based on polymers with a system of conjugated bonds, sulfopolyphenylene ketone (SPP) differing from the known cation exchangers by the high thermostability (up to 250/sup 0/C), and also having the effect of the stabilization of the double bond in unsaturated monomers. The combination of inhibiting and cation exchange properties makes it also possible to use these sulfo-cation exchangers in the processes of esterification of (meth)acrylic acids by alcohols without addition of special inhibitors. The SPP catalyst was tested in esterification processes of acrylic an methacrylic acid by butanol at a pilot plant.

  15. Starch graft poly(methyl acrylate) loose-fill foam: preparation, properties and degradation.

    PubMed

    Chen, L; Gordon, S H; Imam, S H

    2004-01-01

    Starch graft poly(methyl acrylate) (S-g-PMA) was prepared by ceric ion initiation of methyl acrylate in an aqueous corn starch slurry (prime starch) which maximized the accessibility of the starch for graft polymerization. A new ceric ion reaction sequence was established as starch-initiator-methyl acrylate followed by addition of a small amount of ceric ion solution when the graft polymerization was almost complete to quench the reaction. As a result of this improved procedure, no unreacted methyl acrylate monomer remained, and thus, essentially no ungrafted poly(methyl acrylate) homopolymer was formed in the final grafted product. Quantities of the high purity S-g-PMA so prepared in pilot scale were converted to resin pellets and loose-fill foam by single screw and twin screw extrusion. The use of prime starch significantly improved the physical properties of the final loose-fill foam, in comparison to foam produced from regular dry corn starch. The S-g-PMA loose-fill foam had compressive strength and resiliency comparable to expanded polystyrene but higher bulk density. The S-g-PMA loose-fill foam also had better moisture and water resistance than other competitive starch-based materials. Studies indicated that the starch portion in S-g-PMA loose-fill foam biodegraded rapidly, whereas poly(methyl acrylate) remained relatively stable under natural environmental conditions.

  16. Radiation-induced grafting of acrylic acid onto polypropylene film and its biodegradability

    NASA Astrophysics Data System (ADS)

    Mandal, Dev K.; Bhunia, Haripada; Bajpai, Pramod K.; Chaudhari, C. V.; Dubey, K. A.; Varshney, L.

    2016-06-01

    Polypropylene based commodity polyolefins are widely used in packaging, manufacturing, electrical, pharmaceutical and other applications. The aim of the present work is to study the effect of grafting of acrylic acid on the biodegradability of acrylic acid grafted polypropylene. The effect of different conditions showed that grafting percentage increased with increase in monomer concentration, radiation dose and inhibitor concentration but decreased with increase in radiation dose rate. The maximum grafting of 159.4% could be achieved at optimum conditions. The structure of grafted polypropylene films at different degree of grafting was characterized by EDS, FTIR, TGA, DSC, SEM and XRD. EDS studies showed that the increase in acrylic acid grafting percentage increased the hydrophilicity of the grafted films. FTIR studies indicated the presence of acrylic acid on the surface of polypropylene film. TGA studies revealed that thermal stability decreased with increase in grafting percentage. DSC studies showed that melting temperature and crystallinity of the grafted polypropylene films lower than polypropylene film. SEM studies indicated that increase in acrylic acid grafting percentage increased the wrinkles in the grafted films. The maximum biodegradability could be achieved to 6.85% for 90.5% grafting. This suggested that microorganisms present in the compost could biodegrade acrylic acid grafted polypropylene.

  17. MM and QM: Conformational and vibrational spectra analysis of 2-hydroxyethyl acrylate

    NASA Astrophysics Data System (ADS)

    Belaidi, O.; Adjim, M.; Bouchaour, T.; Maschke, U.

    2015-02-01

    2-Hydroxyethyl acrylate is generally used with other acrylic and methacrylic products in order to get the desired characteristics of the final product. In this work we are about to make an assignment of experimental infrared bands with the help of a theoretical quantum chemistry calculations. The exact knowledge of some bands which are not characteristics of acrylic materials will enable us to make a quick analysis with available techniques of low costs for mixtures of polymers based on acrylate and methacrylate molecules. In the experimental part, the infrared spectrum of 2-hydroxyethyl acrylate is obtained by using a FTIR Perkin Elmer model 2000. In the computational part and as first step, the theoretical calculations are performed by the semi-empirical AM1 method for excluding similar structures of 2-hydroxyethyl acrylate molecule by a meticulous conformational analysis. As a second step the obtained structures are optimized using DFT. The simulated frequencies are then scaled and a tentative assignment is made based on band intensities and PED percentages. The theoretical calculations predict the existence of thirteen conformations two of them represent the majority of experimental bands in the infrared spectrum. Two neighbor experimental bands located at 1301 and 1207 cm-1 maybe used as characteristic bands to locate and distinguish the existence of one or both conformations.

  18. Fluorescent Ag nanoclusters prepared in aqueous poly(acrylic acid-co-maleic acid) solutions: a spectroscopic study of their excited state dynamics, size and local environment.

    PubMed

    Dandapat, Manika; Mandal, Debabrata

    2016-01-28

    Stable, fluorescent Ag nanoclusters were prepared in aqueous solutions of Na(+) salt of the carboxylate-rich polymer poly(acrylic acid-co-maleic acid) under brief spells of UV irradiation. The nanoclusters were nearly spherical, with diameters within 1.90 ± 0.50 nm, but displayed a prominent red edge excitation shift (REES) of fluorescence upon exciting within the visible absorption band, indicating heterogeneity of energy level distributions. Spectroscopic studies revealed that irrespective of whether the nanoclusters are excited in their UV or visible absorption bands, their fluorescence always ensues from the same manifold of emissive states, with a broad range of fluorescence lifetimes from ∼150 fs to 1 ns. PMID:26700465

  19. Rehabilitation of anterior teeth with customised incisal guide table

    PubMed Central

    Mall, Priyanka; Singh, Kamleshwar; Rao, Jitendra; Kumar, Lakshya

    2013-01-01

    Restoration of anterior guidance is a major challenge to the clinician in planning of all restorative treatments. An accurate anterior guidance is important for proper function, aesthetics, comfort and phonetics. This article describes anterior rehabilitation of a patient who met with a road traffic accident and lost his anterior teeth. Anterior guidance developed in the provisional restorations was accurately recorded in the customised incisal guide table and permanent restorations were fabricated accordingly. PMID:23709546

  20. Can they really be opposite? A new look at four critical aspects of anterior dental morphology.

    PubMed

    Greenberg, Joseph R

    2008-09-01

    Human dental anatomy has not changed significantly in hundreds of years. Dental students and students of dental laboratory technology learn human dental anatomy as fundamental to their didactic work. Yet, so often we see dental restorations that do not follow the accepted basic design criteria of natural teeth. A possible conclusion is that the information was correctly presented as a basic science, but not completely carried over into clinical practice. When visually essential aspects of dental anatomy and composition are not accurately incorporated into esthetic restorations, patients are not completely served, and practitioners may be frustrated as well. This article reviews four essential aspects of anterior dental morphology--anterior tooth width/length proportions, bilateral symmetry, incisal edges, and incisal embrasures--that often are not accurately incorporated into dental restorations, and positions them in an easy to remember format: opposites.

  1. [Surgical anatomy of the anterior mediastinum].

    PubMed

    Biondi, Alberto; Rausei, Stefano; Cananzi, Ferdinando C M; Zoccali, Marco; D'Ugo, Stefano; Persiani, Roberto

    2007-01-01

    The mediastinum is located from the thoracic inlet to the diaphragm between the left and right pleural cavities and contains vital structures of the circulatory, respiratory, digestive, and nervous system. Over the years, since there are no fascial or anatomic planes, anatomists and radiologists have suggested various schemes for subdividing the mediastinum and several anatomical and radiological classifications of the mediastinum are reported in the literature. The most popular of these scheme divides medistinum, for purposes of description, into two parts: an upper portion, above the upper level of the pericardium, which is named the superior mediastinum; and a lower portion, below the upper level of the pericardium. For clinical purposes, the mediastinum may be subdivided into three major areas, i.e. anterior, middle, and posterior compartments. The anterior mediastinum is defined as the region posterior to the sternum and anterior to the heart and brachiocephalic vessels. It extends from the thoracic inlet to the diaphragm and contains the thymus gland, fat, and lymph nodes. This article will review surgical anatomy of the anterior mediastinum and will focus on the surgical approch to anterior mediastinum and thymic diseases.

  2. Warfare-related secondary anterior cranioplasty

    PubMed Central

    Ebrahimi, Ali; Nejadsarvari, Nasrin; Rasouli, Hamid Reza; Ebrahimi, Azin

    2016-01-01

    Background: Anterior cranial bone defects secondary to global war cranial defects pose a unique reconstructive challenge. The objective of this study was to evaluate the outcomes of alloplastic reconstructions of cranial bone with titanium mesh and fat graft after warfare-related cranial trauma. Patients and Methods: Thirty-five patients at the plastic and reconstructive surgery ward of our hospital underwent anterior cranioplasty with titanium mesh with or without fat grafts from lower abdominal wall. Inclusion criteria were anterior cranial bone defect due to warfare injuries, the mean age of these patients was 31 years (range, 23–48 years). Ninety-five percent were male, and 5% were female. Average follow-up was 12 months. Fat grafts were used to help obliterate endocranial dead spaces. Results: Twenty-five patients (71%) had more than 0.5 cm dead space under cranial defects, and we used fat graft under the titanium mesh. The majority groups of patients (80%) were injured as a result of previous explosive device blasts with or without neurosurgical procedures in the past. The average patient age was 31 years, and 95% of patients were male. The mean anterior cranial defect size was 6 cm × 8 cm, and there were no wound infection or flap necrosis after operations. Conclusion: We recommend this procedure (titanium mesh with or without fat graft) for warfare injured cranial defects in secondary anterior cranial reconstructions. Fat grafts eliminates dead space and reduce secondary complications. PMID:27563609

  3. Anterior approach in THA improves outcomes: affirms.

    PubMed

    Moskal, Joseph T

    2011-09-01

    In general, the literature makes numerous positive claims regarding the direct anterior approach with a fracture table for total hip arthroplasty (THA), including quicker recovery and return to unassisted ambulation, along with reduced soft tissue damage, surgery time, pain, and risk of dislocation with early elimination of hip precautions. The benefits of the direct anterior approach are mostly due from muscle preservation rather than muscle splitting, which occurs with the more traditional approaches. With the use of the muscle-preserving direct anterior approach for THA, there is less muscle damage and earlier return to function, and postoperative precautions are not needed. The most significant improvements in THA have been allowing patients to be immediately weight bearing as tolerated after THA, incorporating a multimodal pain management protocol, and now using the direct anterior approach. There is a learning curve, and I strongly recommend that people attend cadaver-based learning centers as well as surgeon visitations. We must always remember the oath we took to "do no harm," especially when embarking on a new procedure such as the direct anterior approach in THA or any other new procedure or technology. My position in the debate is not whether we should embrace this technique or other new techniques, but rather how they should be introduced.

  4. Hybrid resist systems based on α-substituted acrylate copolymers

    NASA Astrophysics Data System (ADS)

    Ito, Hiroshi; Sundberg, Linda K.; Bozano, Luisa; Lofano, Elizabeth M.; Yamanaka, Kazuhiro; Terui, Yoshiharu; Fujiwara, Masaki

    2009-03-01

    Classical electron-beam resists such as poly(methyl methacrylate) (PMMA) and Nippon Zeon's ZEP function as high resolution and low roughness positive resists on the basis of radiation induced main chain scission to reduce the molecular weight while chemical amplification resists utilized in device manufacturing function on the basis of acidcatalyzed deprotection to change the polarity. In an attempt to increase the resolution and reduce the line roughness of chemical amplification resists, we prepared copolymers that undergo radiation induced main chain scission and acidcatalyzed deprotection. In another word, we wanted to increase the sensitivity of the PMMA resist by incorporating the acid-catalyzed deprotection mechanism in polymers that undergo main chain scission, maintaining the high resolution and low roughness of PMMA. To synthesize such hybrid resist polymers, we selected α-substituted acrylates and α- substituted styrenes. The former included methyl methacrylate (MMA), t-butyl methacrylate (TBMA), methyl α- fluoroacrylate (MFA), t-butyl α-fluoroacrylate (TBFA), and t-butyl α-trifluoromethylacrylate (TBTFMA) and the latter α-methylstyrene (αMEST), α-methyleneindane (αMEIN), and α-methylenetetralin (αMETL). The α-substituted tbutyl acrylic esters were copolymerized with the methyl esters and also with α-substituted styrenic monomers using 2, 2'-azobis(isobutyronitrile) (AIBN). Hybrid resists were formulated by adding a photochemical acid generator and a base quencher to the copolymers and developers were selected by studying the dissolution behavior of unexposed and 254 nm exposed resist films using a quartz crystal microbalance (QCM). In addition to the difference in the imaging mechanism, PMMA and ZEP differ from the chemical amplification resists in developers; organic solvent vs. aqueous base. We were interested in looking also into the influence of the developer on the lithographic performance. Contrast curves were generated by exposing

  5. Saddle-node dynamics for edge detection

    SciTech Connect

    Wong, Y.F.

    1994-09-01

    The author demonstrates how the formulation of a nonlinear scale-space filter can be used for edge detection and junction analysis. By casting edge-preserving filtering in terms of maximizing information content subject to an average cost function, the computed cost at each pixel location becomes a local measure of edgeness. This computation depends on a single scale parameter and the given image data. Unlike previous approaches which require careful tuning of the filter kernels for various types of edges, this scheme is general enough to be able to handle different edges, such as lines, step edges, corners and junctions. Anisotropy in the data is handled automatically by the nonlinear dynamics.

  6. Edge-on thick discs

    NASA Astrophysics Data System (ADS)

    Kasparova, A.; Katkov, I.; Chilingarian, I.; Silchenko, O.; Moiseev, A.; Borisov, S.

    2016-06-01

    Although thick stellar discs are detected in nearly all edge-on disc galaxies, their formation scenarios still remain a matter of debate. Due to observational difficulties, there is a lack of information about their stellar populations. Using the Russian 6-m telescope BTA we collected deep spectra of thick discs in three edge-on early-type disc galaxies located in different environments: NGC4111 in a dense group, NGC4710 in the Virgo cluster, and NGC5422 in a sparse group. We see intermediate age (4 ‑ 5 Gyr) metal rich ([Fe/H] ~ ‑0.2 ‑ 0.0 dex) stellar populations in NGC4111 and NGC4710. On the other hand, NGC5422 does not harbour young stars, its only disc is thick and old (10 Gyr) and its α-element abundance suggests a long formation epoch implying its formation at high redshift. Our results prove the diversity of thick disc formation scenarios.

  7. Linear array optical edge sensor

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K. (Inventor); Primus, Howard C. (Inventor)

    1987-01-01

    A series of independent parallel pairs of light emitting and detecting diodes for a linear pixel array, which is laterally positioned over an edge-like discontinuity in a workpiece to be scanned, is disclosed. These independent pairs of light emitters and detectors sense along intersecting pairs of separate optical axes. A discontinuity, such as an edge in the sensed workpiece, reflects a detectable difference in the amount of light from that discontinuity in comparison to the amount of light that is reflected on either side of the discontinuity. A sequentially sychronized clamping and sampling circuit detects that difference as an electrical signal which is recovered by circuitry that exhibits an improved signal-to-noise capability for the system.

  8. Bone Marrow Nails Created by Percutaneous Osteoplasty for Long Bone Fracture: Comparisons Among Acrylic Cement Alone, Acrylic-Cement-Filled Bare Metallic Stent, and Acrylic-Cement-Filled Covered Metallic Stent

    SciTech Connect

    Nakata, Kouhei; Kawai, Nobuyuki; Sato, Morio Cao, Guang; Sahara, Shinya; Sonomura, Tetsuo; Takasaka, Isao; Minamiguchi, Hiroki; Nakai, Motoki

    2011-06-15

    Purpose: This study was designed to compare the strength among bone marrow nails created to treat long bone fractures using interventional procedures. Methods: Twelve resected intact tibiae of healthy swine were used. A circumferential bone fracture was made in nine tibiae and restored with the following created bone marrow nails: acrylic cement alone (ACA) (n = 3), acrylic-cement-filled bare metallic stent (AC-FBMS) (n = 3), and acrylic-cement-filled covered metallic (AC-FCMS) stent (n = 3). The remaining intact tibiae (n = 3) were used as controls. Results: A bone marrow nail was successfully achieved within 30 min in all swine. The maximum injection volume of acrylic cement for creating ACA, AC-FBMS, and AC-FCMS was 1.7 {+-} 0.3, 3.2 {+-} 0.4, and 2.9 {+-} 0.4 mL, respectively. The thickness of bone marrow nail created in the ACA, AC-FBMS, and AC-FCMS groups was 3.6 {+-} 1.0, 10.3 {+-} 0.26, and 9.6 {+-} 0.32 mm, respectively (AC-FBMS group versus AC-FCMS group, p = 0.038), probably because of leakage of acrylic cement surrounding the interstices. The maximum bending power (kilonewton) and bending strength (newton/mm{sup 2}) in the normal long bone, ACA, AC-FBMS, and AC-FCMS groups were: 1.70 {+-} 0.25 and 79.2 {+-} 16.1; 0.21 {+-} 0.11 and 8.8 {+-} 2.8; 0.46 {+-} 0.06 and 18.2 {+-} 1.6; and 0.18 {+-} 0.04 and 7.8 {+-} 2.7, respectively. Conclusions: Although the maximum bending power and bending strength of AC-FBMS were not satisfactory, it was the most robust of the three marrow nails for restoring fractured long bone.

  9. Gyrosheath near the tokamak edge

    SciTech Connect

    Hazeltine, R.D.; Xiao, H. . Inst. for Fusion Studies); Valanju, P.M. . Fusion Research Center)

    1993-03-01

    A new model for the structure of the radial electric field profile in the edge during the H-mode is proposed. Charge separation caused by the difference between electron and ion gyromotion, or more importantly in a tokamak, the banana motion (halo effect) can self-consistently produce an electric dipole moment that causes the sheared radial electric field. The calculated results based on the model are consistent with D-III D and TEXTOR experimental results.

  10. Edge-driven microplate kinematics

    USGS Publications Warehouse

    Schouten, Hans; Klitgord, Kim D.; Gallo, David G.

    1993-01-01

    It is known from plate tectonic reconstructions that oceanic microplates undergo rapid rotation about a vertical axis and that the instantaneous rotation axes describing the microplate's motion relative to the bounding major plates are frequently located close to its margins with those plates, close to the tips of propagating rifts. We propose a class of edge-driven block models to illustrate how slip across the microplate margins, block rotation, and propagation of rifting may be related to the relative motion of the plates on either side. An important feature of these edge-driven models is that the instantaneous rotation axes are always located on the margins between block and two bounding plates. According to those models the pseudofaults or traces of disrupted seafloor resulting from the propagation of rifting between microplate and major plates may be used independently to approximately trace the continuous kinematic evolution of the microplate back in time. Pseudofault geometries and matching rotations of the Easter microplate show that for most of its 5 m.y. history, block rotation could be driven by the drag of the Nazca and Pacific plates on the microplate's edges rather than by a shear flow of mantle underneath.

  11. Anterior compartment syndrome: a case report.

    PubMed

    Pearl, A J

    1981-01-01

    The chronic form of the anterior compartment syndrome can be overlooked if the symptoms of leg pain are attributed to shin splints. Herein is presented a case report which I feel represents an acute exacerbation of the chronic form of anterior compartment syndrome in a long-distance runner secondary to bleeding into the extensor digitorum longus muscle. Chronic anterior compartment syndrome can be a disabling injury which may require a fasciotomy, depending upon the severity and duration of the patient's symptoms and the intracompartmental pressures. The lay term "shin splints" should be separated from medical use, and a more reliable assessment of the etiology of the patient's symptoms should be made. The term shin splints should be utilized only for pain localized to the posterior medial border of the tibia at the origin of the posterior tibialis muscle.

  12. Esthetic crown lengthening for maxillary anterior teeth.

    PubMed

    Sonick, M

    1997-08-01

    In the maxillary anterior region, the gingival labial margin position is an important parameter in the achievement of an ideal smile. The relationship between the periodontium and the restoration is critical if gingival health and esthetics are to be achieved. Periodontal therapy is a necessary and useful adjunct when any anterior restoration is undertaken. Anterior surgical crown lengthening may be undertaken to avoid restorative margin impingement on the biologic width. Crown lengthening is also used to alter the gingival labial profiles. This article discusses the esthetic parameters of ideal gingival labial positions and presents a classification of crown-lengthening procedures and the procedure for a two-stage crown-lengthening technique. The two-stage crown-lengthening technique is surgically precise because healing is predictable.

  13. Tumors of the anterior skull base.

    PubMed

    Ivan, Michael E; Han, Seunggu J; Aghi, Manish K

    2014-04-01

    A variety of histologic tumor types are present in the anterior skull base. Primary tumors of this area may be derived from the bone, paranasal sinuses, nasopharynx, dura, cranial nerves, pituitary gland and brain. Symptoms are caused mostly through mass effect but, if the tumor becomes aggressive, also through invasion. Selection of surgical approaches to the anterior skull base is based upon balancing risk reduction with maximizing extent of resection. Here we review a spectrum of neoplastic entities found in the anterior skull base in adults and discuss clinical and radiographic presentation, treatment options, and outcomes. Surgical resection remains the mainstay in treatment of these tumors, particularly in the hands of experienced surgeons exercising proper patient and case selection. PMID:24564556

  14. Anterior eye development and ocular mesenchyme

    PubMed Central

    Cvekl, Aleš; Tamm, Ernst R.

    2007-01-01

    Summary During development of the anterior eye segment, cells that originate from the surface epithelium or the neuroepithelium need to interact with mesenchymal cells, which predominantly originate from the neural crest. Failures of proper interaction result in a complex of developmental disorders such Peters’ anomaly, Axenfeld-Rieger’s syndrome or aniridia. Here we review the role of transcription factors that have been identified to be involved in the coordination of anterior eye development. Among these factors is PAX6, which is active in both epithelial and mesenchymal cells during ocular development, albeit at different doses and times. We propose that PAX6 is a key element that synchronizes the complex interaction of cell types of different origin, which are all needed for proper morphogenesis of the anterior eye. We discuss several molecular mechanisms that might explain the effects of haploinsufficiency of PAX6 and other transcription factors, and the broad variation of the resulting phenotypes. PMID:15057935

  15. Analysis of Femtosecond Laser Assisted Capsulotomy Cutting Edges and Manual Capsulorhexis Using Environmental Scanning Electron Microscopy

    PubMed Central

    Serrao, Sebastiano; Lombardo, Giuseppe; Desiderio, Giovanni; Buratto, Lucio; Schiano-Lomoriello, Domenico; Pileri, Marco; Lombardo, Marco

    2014-01-01

    Purpose. To investigate the structure and irregularity of the capsulotomy cutting edges created by two femtosecond (FS) laser platforms in comparison with manual continuous circular capsulorhexis (CCC) using environmental scanning electron microscopy (eSEM). Methods. Ten anterior capsulotomies were obtained using two different FS laser cataract platforms (LenSx, n = 5, and Victus, n = 5). In addition, five manual CCC (n = 5) were obtained using a rhexis forceps. The specimens were imaged by eSEM (FEI Quanta 400, OR, USA). Objective metrics, which included the arithmetic mean deviation of the surface (Sa) and the root-mean-square deviation of the surface (Sq), were used to evaluate the irregularity of both the FS laser capsulotomies and the manual CCC cutting edges. Results. Several microirregularities were shown across the FS laser capsulotomy cutting edges. The edges of manually torn capsules were shown, by comparison of Sa and Sq values, to be smoother (P < 0.05) than the FS laser capsulotomy edges. Conclusions. Work is needed to understand whether the FS laser capsulotomy edge microirregularities, not seen in manual CCC, may act as focal points for the concentration of stress that would increase the risk of capsular tear during phacoemulsification as recently reported in the literature. PMID:25505977

  16. Analysis of femtosecond laser assisted capsulotomy cutting edges and manual capsulorhexis using environmental scanning electron microscopy.

    PubMed

    Serrao, Sebastiano; Lombardo, Giuseppe; Desiderio, Giovanni; Buratto, Lucio; Schiano-Lomoriello, Domenico; Pileri, Marco; Lombardo, Marco

    2014-01-01

    Purpose. To investigate the structure and irregularity of the capsulotomy cutting edges created by two femtosecond (FS) laser platforms in comparison with manual continuous circular capsulorhexis (CCC) using environmental scanning electron microscopy (eSEM). Methods. Ten anterior capsulotomies were obtained using two different FS laser cataract platforms (LenSx, n = 5, and Victus, n = 5). In addition, five manual CCC (n = 5) were obtained using a rhexis forceps. The specimens were imaged by eSEM (FEI Quanta 400, OR, USA). Objective metrics, which included the arithmetic mean deviation of the surface (Sa) and the root-mean-square deviation of the surface (Sq), were used to evaluate the irregularity of both the FS laser capsulotomies and the manual CCC cutting edges. Results. Several microirregularities were shown across the FS laser capsulotomy cutting edges. The edges of manually torn capsules were shown, by comparison of Sa and Sq values, to be smoother (P < 0.05) than the FS laser capsulotomy edges. Conclusions. Work is needed to understand whether the FS laser capsulotomy edge microirregularities, not seen in manual CCC, may act as focal points for the concentration of stress that would increase the risk of capsular tear during phacoemulsification as recently reported in the literature.

  17. Subsidence and Nonunion after Anterior Cervical Interbody Fusion Using a Stand-Alone Polyetheretherketone (PEEK) Cage

    PubMed Central

    Yang, Jae Jun; Yu, Chang Hun; Yeom, Jin Sup; Lee, Jae Hyup; Lee, Choon-Ki

    2011-01-01

    Background The purposes of the present study are to evaluate the subsidence and nonunion that occurred after anterior cervical discectomy and fusion using a stand-alone intervertebral cage and to analyze the risk factors for the complications. Methods Thirty-eight patients (47 segments) who underwent anterior cervical fusion using a stand-alone polyetheretherketone (PEEK) cage and an autologous cancellous iliac bone graft from June 2003 to August 2008 were enrolled in this study. The anterior and posterior segmental heights and the distance from the anterior edge of the upper vertebra to the anterior margin of the cage were measured on the plain radiographs. Subsidence was defined as ≥ a 2 mm (minor) or 3 mm (major) decrease of the segmental height at the final follow-up compared to that measured at the immediate postoperative period. Nonunion was evaluated according to the instability being ≥ 2 mm in the interspinous distance on the flexion-extension lateral radiographs. Results The anterior and posterior segmental heights decreased from the immediate postoperative period to the final follow-up at 1.33 ± 1.46 mm and 0.81 ± 1.27 mm, respectively. Subsidence ≥ 2 mm and 3 mm were observed in 12 segments (25.5%) and 7 segments (14.9%), respectively. Among the expected risk factors for subsidence, a smaller anteroposterior (AP) diameter (14 mm vs. 12 mm) of cages (p = 0.034; odds ratio [OR], 0.017) and larger intraoperative distraction (p = 0.041; OR, 3.988) had a significantly higher risk of subsidence. Intervertebral nonunion was observed in 7 segments (7/47, 14.9%). Compared with the union group, the nonunion group had a significantly higher ratio of two-level fusion to one-level fusions (p = 0.001). Conclusions Anterior cervical fusion using a stand-alone cage with a large AP diameter while preventing anterior intraoperative over-distraction will be helpful to prevent the subsidence of cages. Two-level cervical fusion might require more careful attention

  18. Highly luminescent lead sulfide nanocrystals in organic solvents and water through ligand exchange with poly(acrylic acid).

    PubMed

    Lin, Wanjuan; Fritz, Karolina; Guerin, Gerald; Bardajee, Ghasem R; Hinds, Sean; Sukhovatkin, Vlad; Sargent, Edward H; Scholes, Gregory D; Winnik, Mitchell A

    2008-08-01

    Hydrophobic lead sulfide quantum dots (PbS/OA) synthesized in the presence of oleic acid were transferred from nonpolar organic solvents to polar solvents such as alcohols and water by a simple ligand exchange with poly(acrylic acid) (PAA). Ligand exchange took place rapidly at room temperature When a colloidal solution of PbS/OA in tetrahydrofuran (THF) was treated with excess PAA, the PbS/PAA nanocrystals that formed were insoluble in hexane and toluene but could be dissolved in methanol or water, where they formed colloidal solutions that were stable for months. Ligand exchange was accompanied by a small blue shift in the band-edge absorption, consistent with a small reduction in particle size. While there was a decrease in quantum yield associated with ligand exchange and transfer to polar solvents, as is commonly found for colloidal quantum dots, the quantum yields determined were impressively high: PbS/OA in toluene (82%) and in THF (58%); PbS/PAA in THF (42%) and in water (24%). The quantum yields for the PbS/PAA solutions decreased over time as the solutions were allowed to age in the presence of air.

  19. New Poly(dimethylsiloxane)/Poly(perfluorooctylethyl acrylate) Block Copolymers: Structure and Order Across Multiple Length Scales in Thin Films

    SciTech Connect

    E Martinelli; G Galli; S Krishnan; M Paik; C Ober; D Fischer

    2011-12-31

    Three sets of a new class of low surface tension block copolymers were synthesized consisting of a poly(dimethylsiloxane) (PDMS) block and a poly(perfluorooctylethyl acrylate) (AF8) block. The polymers were prepared using a bromo-terminated PDMS macroinitiator, to which was attached an AF8 block grown using atom transfer radical polymerization (ATRP) in such a designed way that the molecular weight and composition of the two polymer blocks were regularly varied. The interplay of both the phase separated microstructure and the mesomorphic character of the fluorinated domains with their effect on surface structure was evaluated using a suite of analytical tools. Surfaces of spin-coated and thermally annealed films were assessed using a combination of X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine structure (NEXAFS) studies. Both atomic force microscopy (AFM) measurements and grazing incidence small angle X-ray scattering (GISAXS) studies were carried out to evaluate the microstructure of the thin films. Even in block copolymers in which the PDMS block was the majority component, a significant presence of the lower surface energy AF8 block was detected at the film surface. Moreover, the perfluorooctyl helices of the AF8 repeat units were highly oriented at the surface in an ordered, tilted smectic structure, which was compared with those of the bulk powder samples using wide-angle X-ray powder diffraction (WAXD) studies.

  20. [Adaptation of acrylic resin dentures polymerized using various activation modes].

    PubMed

    Takamata, T; Inoue, Y; Hashimoto, K; Sugitou, S; Arakawa, H; Kurasawa, I

    1989-12-01

    The purpose of this in vitro study was to compare the dimensional accuracy of maxillary dentures made using a conventional heat-activated PMMA resin, a pour resin, a visible light-activated resin, and a microwave-activated acrylic resin. Two simple methods for measuring dimensional accuracy were used: (1) weight of impression material entrapped between the base and master die and (2) measurement of the posterior border gap at five locations. The volume of space between the denture base and the master die was determined by (1) computation and (2) estimation. Statistical analysis (Bartlett, ANOVA and Tukey's Tests) supported the following conclusions: (1) all groups showed a processing contraction, most apparent from buccal flange to buccal flange, (2) the poorest fitting group was processed in a brass flask and a water bath at a temperature which rose from 70 to 100 degrees C, using a heat activated resin (Acron), (3) the visible light activated resin (Triad) produced dentures of intermediate accuracy, as did Acupac 20 when either heat or microwave activated, (4) the two best fitting groups were prepared from a chemically activated resin system using pressure at low heat (PER form), and the resin developed for microwave activation (Acron MC).

  1. Radiation grafting of acrylic acid onto polypropylene films

    NASA Astrophysics Data System (ADS)

    Taher, N. H.; Dessouki, A. M.; Khalil, F. H.

    A study has been made for the preparation of membranes by the direct radiation grafting of acrylic acid (AAc) onto polypropylene (PP) films. The appropriate reaction conditions were selected under which the graft polymerization was carried out successfully. The effect of different solvents such as benzene, methanol/water mixture, isopropanol/water mixture, dimethyl formalide and distilled water on the swelling and grafting process of AAc onto PP films was investigated. In this grafting system ammonium ferrous sulphate (Mohr's salt) and ferric chloride were used as inhibitors to minimize the homopolymerization of AAc and the suitable concentration of the inhibitor was found to be 1.0 and 1.5 wt% for Mohr's salt and ferric chloride, respectively. Also, the effect of monomer concentration on the rate of grafting was investigated. The dependence of the grafting rate on monomer concentration was found to be 1.1 order. This grafting system proceeded by diffusion controlled process. Some selected properties of the grafted films such as swelling behavior, gel determination, mechanical and electrical properties were also investigated. It was found that the grafted membranes possess good hydrophilic properties which may make them promising in some practical applications.

  2. Prosthetic rehabilitation of the gagging patient using acrylic training plates.

    PubMed

    Ali, Rahat; Altaie, Asmaa; Morrow, Leean

    2015-01-01

    Patients with a hyper-responsive gag reflex pose dentists with a challenging problem. The gag reflex of some patients may be so severe that patients (and operating clinician) may favour extraction of any painful, infected teeth as opposed to more lengthy and complicated procedures such as root canal therapy. However, consistently adopting this approach may render the gagging patient completely edentulous. Such patients may then present to the dental surgeon requesting tooth replacement with some form of denture. This in itself can be a challenging task given the difficulties one may experience whilst taking impressions in this cohort of patients. This article will discuss the prosthetic management of the maxillary arch in edentulous patients with a severe gag reflex. There will be particular emphasis on the aetiology and physiology of the gag reflex, impression-taking techniques to allow the construction of an acrylic training plate (as an interim measure), principles of training plate design and construction of the definitive removable denture. Clinical Relevance: Removable training plates can be used as an interim measure to desensitize edentulous gagging patients before providing them with a definitive removable denture.

  3. Interaction of photosensitive surfactant with DNA and poly acrylic acid

    SciTech Connect

    Zakrevskyy, Yuriy Paasche, Jens; Lomadze, Nino; Santer, Svetlana; Cywinski, Piotr; Cywinska, Magdalena; Reich, Oliver; Löhmannsröben, Hans-Gerd

    2014-01-28

    In this paper, we investigate interactions and phase transitions in polyelectrolyte-surfactant complexes formed between a cationic azobenzene-containing surfactant and two types of polyelectrolytes: natural (DNA) or synthetic (PAA: poly acrylic acid). The construction of a phase diagram allowed distancing between four major phases: extended coil conformation, colloidally stable compacted globules, colloidal instability range, and surfactant-stabilized compact state. Investigation on the complexes’ properties in different phases and under irradiation with UV light provides information about the role of the surfactant's hydrophobic trans isomers both in the formation and destruction of DNA and PAA globules as well as in their colloidal stabilization. The trans isomer shows much stronger affinity to the polyelectrolytes than the hydrophilic cis counterpart. There is no need for complete compensation of the polyelectrolyte charges to reach the complete compaction. On contrary to the findings previously reported in the literature, we demonstrate – for the first time – complete polyelectrolyte compaction which occurs already at 20% of DNA (and at 50% of PAA) charge compensation. The trans isomer plays the main role in the compaction. The aggregation between azobenzene units in the photosensitive surfactant is a driving force of this process. The decompaction can be realized during UV light irradiation and is strongly influenced by the interplay between surfactant-surfactant and surfactant-DNA interactions in the compacted globules.

  4. Synthesis of acrylates and methacrylates from coal-derived syngas

    SciTech Connect

    Spivey, J.J.; Gogate, M.R.; Jang, B.W.L.

    1995-12-31

    Acrylates and methacrylates are among the most widely used chemical intermediates in the world. One of the key chemicals of this type is methyl methacrylate. Of the 4 billion pounds produced each year, roughly 85% is made using the acetone-cyanohydrin process, which requires handling of large quantities of hydrogen cyanide and produces ammonium sulfate wastes that pose an environmental disposal challenge. The U.S. Department of Energy and Eastman Chemical Company are sharing the cost of research to develop an alternative process for the synthesis of methyl methacrylate from syngas. Research Triangle Institute is focusing on the synthesis and testing of active catalysts for the condensation reactions, and Bechtel is analyzing the costs to determine the competitiveness of several process alternatives. Results thus far show that the catalysts for the condensation of formaldehyde and the propionate are key to selectively producing the desired product, methacrylic acid, with a high yield. These condensation catalysts have both acid and base functions and the strength and distribution of these acid-base sites controls the product selectivity and yield.

  5. Color stability of acrylic resin adhesives with different initiation modes.

    PubMed

    Tanoue, Naomi; Koishi, Yoshikazu; Yanagida, Hiroaki; Atsuta, Mitsuru; Shimada, Kazuki; Matsumura, Hideo

    2004-09-01

    The purpose of this study was to evaluate the color stability of two acrylic resin adhesives with different activation systems: a benzoyl peroxide (BPO)-amine redox system and a tri-n-butylborane (TBB) derivative system. The colorimetric values of the two resins in different shades (Clear and Ivory) were determined (n=5) 24 hours after polymerization as a baseline using the L*a*b* system of the Commission Internationale de l'Eclairage (CIE). The specimens were thereafter immersed in distilled water, and the color difference (deltaE*) values were calculated. After 24 weeks, the TBB-initiated material showed a significantly (p<0.05) lower color change than the BPO-amine-initiated material. The deltaE* values for the BPO-amine-initiated materials were 6.9 for Clear and 15.8 for Ivory, whereas those for the TBB-initiated materials were 1.3 and 1.8 respectively. Thus, it was concluded that the TBB-initiated material had superior color stability to that of the BPO-amine-initiated material.

  6. Cytocompatible antifungal acrylic resin containing silver nanoparticles for dentures

    PubMed Central

    Acosta-Torres, Laura Susana; Mendieta, Irasema; Nuñez-Anita, Rosa Elvira; Cajero-Juárez, Marcos; Castaño, Víctor M

    2012-01-01

    Background Inhibition of Candida albicans on denture resins could play a significant role in preventing the development of denture stomatitis. The safety of a new dental material with antifungal properties was analyzed in this work. Methods Poly(methyl methacrylate) [PMMA] discs and PMMA-silver nanoparticle discs were formulated, with the commercial acrylic resin, Nature-CrylTM, used as a control. Silver nanoparticles were synthesized and characterized by ultraviolet-visible spectroscopy, dispersive Raman spectroscopy, and transmission electron microscopy. The antifungal effect was assessed using a luminescent microbial cell viability assay. Biocompatibility tests were carried out using NIH-3T3 mouse embryonic fibroblasts and a Jurkat human lymphocyte cell line. Cells were cultured for 24 or 72 hours in the presence or absence of the polymer formulations and analyzed using three different tests, ie, cellular viability by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and cell proliferation by enzyme-linked immunosorbent assay BrdU, and genomic DNA damage (Comet assay). Finally, the samples were evaluated mechanically, and the polymer-bearing silver nanoparticles were analyzed microscopically to evaluate dispersion of the nanoparticles. Results The results show that PMMA-silver nanoparticle discs significantly reduce adherence of C. albicans and do not affect metabolism or proliferation. They also appear not to cause genotoxic damage to cells. Conclusion The present work has developed a new biocompatible antifungal PMMA denture base material. PMID:22969297

  7. Spallation Characteristics of Poly-Methyl Meth-Acrylic (PMMA)

    NASA Astrophysics Data System (ADS)

    Bartkowski, Peter; Dandekar, D. P.

    1999-06-01

    This work describes the results derived from plane shock wave spallation experiments performed on Poly-Methyl Meth-Acrylic (PMMA) Polymer. These experiments were conducted using the Army Research Laboratories 102 mm Bore, 8 m long Light Gas Gun located at Aberdeen Proving Ground, MD. The PMMA used in this work was manufactured by Rohm & Haas as their Ultra-Violet Absorbing (UVA), Type II Plexiglass. Its density is 1.188 Mg/m3 and longitudinal shock velocity is 2.72 mm/μ s. Spallation experiments were conducted at impact stresses between 0.2 and 2.0 GPa. The PMMA appears to exhibit a constant tensile strength of 0.15 GPa up to an impact stress of 0.75 GPa. Unlike metal and ceramic materials, the PMMA exhibits a dwell time in the spallation inversly proportional to the impact stress. At a low impact stress of 0.40 GPa, spallation of the PMMA occurs over a time period of 0.80 micro-seconds. At an impact stress of 0.75 GPa, the spallation occurs over 0.40 micro-seconds. This variation in time required to spall the PMMA will be analyzed and theories discussed.

  8. Thiol-ene/acrylate substrates for softening intracortical electrodes.

    PubMed

    Ware, Taylor; Simon, Dustin; Liu, Clive; Musa, Tabassum; Vasudevan, Srikanth; Sloan, Andrew; Keefer, Edward W; Rennaker, Robert L; Voit, Walter

    2014-01-01

    Neural interfaces have traditionally been fabricated on rigid and planar substrates, including silicon and engineering thermoplastics. However, the neural tissue with which these devices interact is both 3D and highly compliant. The mechanical mismatch at the biotic-abiotic interface is expected to contribute to the tissue response that limits chronic signal recording and stimulation. In this work, novel ternary thiol-ene/acrylate polymer networks are used to create softening substrates for neural recording electrodes. Thermomechanical properties of the substrates are studied through differential scanning calorimetry and dynamic mechanical analysis both before and after exposure physiological conditions. This substrate system softens from more than 1 GPa to 18 MPa on exposure to physiological conditions: reaching body temperature and taking up less than 3% fluid. The impedance of 177 µm(2) gold electrodes electroplated with platinum black fabricated on these substrates is measured to be 206 kΩ at 1 kHz. Specifically, intracortical electrodes are fabricated, implanted, and used to record driven neural activity. This work describes the first substrate system that can use the full capabilities of photolithography, respond to physiological conditions by softening markedly after insertion, and record driven neural activity for 4 weeks.

  9. Acrylic bone cement in total joint arthroplasty: A review.

    PubMed

    Saleh, Khaled J; El Othmani, Mouhanad M; Tzeng, Tony H; Mihalko, William M; Chambers, Monique C; Grupp, Thomas M

    2016-05-01

    Acrylic bone cement has a variety of applications in orthopedic surgery. Primary uses in total arthroplasties are limited to prostheses fixation and antibiotic delivery. With the large number of total joint arthroplasties expected to continue to rise, understanding the role bone cement plays in the success of total joint arthroplasty can have a significant impact on daily practice. The literature is inconclusive on whether cemented or cementless fixation technique is superior, and choice of fixation type is mainly determined by surgeon preference and experience. Surgeons should understand that if poor techniques exist, short-term outcomes of the replaced joint may be at risk. Statement of clinical significance: This article attempts to clarify some points of bone cement use through a review of the mechanical properties related to bone cement, a comparison to alternative materials, influence of additives, and the effects on surgical outcomes. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:737-744, 2016. PMID:26852143

  10. Interaction of photosensitive surfactant with DNA and poly acrylic acid.

    PubMed

    Zakrevskyy, Yuriy; Cywinski, Piotr; Cywinska, Magdalena; Paasche, Jens; Lomadze, Nino; Reich, Oliver; Löhmannsröben, Hans-Gerd; Santer, Svetlana

    2014-01-28

    In this paper, we investigate interactions and phase transitions in polyelectrolyte-surfactant complexes formed between a cationic azobenzene-containing surfactant and two types of polyelectrolytes: natural (DNA) or synthetic (PAA: poly acrylic acid). The construction of a phase diagram allowed distancing between four major phases: extended coil conformation, colloidally stable compacted globules, colloidal instability range, and surfactant-stabilized compact state. Investigation on the complexes' properties in different phases and under irradiation with UV light provides information about the role of the surfactant's hydrophobic trans isomers both in the formation and destruction of DNA and PAA globules as well as in their colloidal stabilization. The trans isomer shows much stronger affinity to the polyelectrolytes than the hydrophilic cis counterpart. There is no need for complete compensation of the polyelectrolyte charges to reach the complete compaction. On contrary to the findings previously reported in the literature, we demonstrate - for the first time - complete polyelectrolyte compaction which occurs already at 20% of DNA (and at 50% of PAA) charge compensation. The trans isomer plays the main role in the compaction. The aggregation between azobenzene units in the photosensitive surfactant is a driving force of this process. The decompaction can be realized during UV light irradiation and is strongly influenced by the interplay between surfactant-surfactant and surfactant-DNA interactions in the compacted globules. PMID:25669583

  11. Controlled Transdermal Iontophoresis by Polypyrrole/Poly(Acrylic Acid) Hydrogel

    NASA Astrophysics Data System (ADS)

    Chansai, Phithupha; Sirivat, Anuvat

    2008-03-01

    Transdermal drug delivery system delivers a drug into a body at desired site and rate. The conductive polymer-hydrogel blend between polypyrrole (PPy) doped with anionic drug and poly(acrylic acid) (PAA) were developed as a matrix/carrier of drug for the transdermal drug delivery in which the characteristic releases depend on the electrical field applied. The PAA films and their blend films were prepared by solution casting using ethylene glycol dimethacrylate (EGDMA) as a crosslinking agent. A mechanical blending of PPy particles and PAA matrix was then carried out. Drug diffusions in the blended PPy/PAA hydrogel and the non-blended one were investigated and determined by using a modified Franz-diffusion cell with an acetate buffer, pH 5.5, at 37 0C, for a period of 48 hours to determine the effects of crosslinking ratio and electric field strength. Amounts of the released drug were measured by UV-Visible spectrophotometry. The diffusion coefficient of drug was determined through the Higuchi equation via different conditions, with and without an electric field. Moreover, thermal properties and electrical conductivity of the polypyrrole and drug-loaded polypyrrole were investigated by means of the thermogravimetric analysis and by using a two-point probe meter, respectively.

  12. Device for simulating anterior segment surgery.

    PubMed

    Otto, Clifton S

    2005-07-01

    To provide a more realistic method for practicing anterior segment surgery, a device was designed that incorporates aspects of currently available cadaver globe fixation methods. A Styrofoam head was fitted with a funnel and tubing system that allows for direct application of variable external suction to a globe placed in an artificial socket. Prototypes were tested in a wet lab environment, which demonstrated that this method provides reliable globe fixation and allows for variable control of intraocular pressure during a variety of anterior and posterior segment surgical techniques.

  13. Treatment selection for anterior endodontically involved teeth.

    PubMed

    Rifkin, Robert; McLaren, Ed

    2004-09-01

    Innovations in material science and clinical techniques have expanded the number of treatment options available for nonvital anterior teeth. These options include the use of composite to fill the access opening with no additional treatment, crown placement, orthodontic extrusion, crown lengthening with or without orthodontic extrusion, dowel restorations with crown placement, and fixed bridge or implant therapy when extraction is necessary. Clinicians need to understand the benefits and limitations of each option in order to provide their patients with optimum function and aesthetics. Using case presentations, this article describes predictable approaches for the diagnosis, treatment planning, and restoration or replacement of endodontically treated teeth in the anterior region.

  14. Chemistry at the Edge of Graphene.

    PubMed

    Bellunato, Amedeo; Arjmandi Tash, Hadi; Cesa, Yanina; Schneider, Grégory F

    2016-03-16

    The selective functionalization of graphene edges is driven by the chemical reactivity of its carbon atoms. The chemical reactivity of an edge, as an interruption of the honeycomb lattice of graphene, differs from the relative inertness of the basal plane. In fact, the unsaturation of the pz orbitals and the break of the π conjugation on an edge increase the energy of the electrons at the edge sites, leading to specific chemical reactivity and electronic properties. Given the relevance of the chemistry at the edges in many aspects of graphene, the present Review investigates the processes and mechanisms that drive the chemical functionalization of graphene at the edges. Emphasis is given to the selective chemical functionalization of graphene edges from theoretical and experimental perspectives, with a particular focus on the characterization tools available to investigate the chemistry of graphene at the edge.

  15. Edge localized mode control with an edge resonant magnetic perturbation

    SciTech Connect

    Moyer, R.A.; Boedo, J.A.; Rudakov, D.L.; Evans, T.E.; Osborne, T.H.; Gohil, P.; Groebner, R.J.; Jackson, G.L.; La Haye, R.J.; Leonard, A.W.; Schaffer, M.J.; Snyder, P.B.; West, W.P.; Thomas, P.R.; Becoulet, M.; Harris, J.; Finken, K.-H.; Doyle, E.J.; Rhodes, T.L.; Wang, G.

    2005-05-15

    A low amplitude ({delta}b{sub r}/B{sub T}=1 part in 5000) edge resonant magnetic field perturbation with toroidal mode number n=3 and poloidal mode numbers between 8 and 15 has been used to suppress most large type I edge localized modes (ELMs) without degrading core plasma confinement. ELMs have been suppressed for periods of up to 8.6 energy confinement times when the edge safety factor q{sub 95} is between 3.5 and 4. The large ELMs are replaced by packets of events (possibly type II ELMs) with small amplitude, narrow radial extent, and a higher level of magnetic field and density fluctuations, creating a duty cycle with long 'active' intervals of high transport and short 'quiet' intervals of low transport. The increased transport associated with these events is less impulsive and slows the recovery of the pedestal profiles to the values reached just before the large ELMs without the n=3 perturbation. Changing the toroidal phase of the perturbation by 60 deg. with respect to the best ELM suppression case reduces the ELM amplitude and frequency by factors of 2-3 in the divertor, produces a more stochastic response in the H-mode pedestal profiles, and displays similar increases in small scale events, although significant numbers of large ELMs survive. In contrast to the best ELM suppression case where the type I ELMs are also suppressed on the outboard midplane, the midplane recycling increases until individual ELMs are no longer discernable. The ELM response depends on the toroidal phase of the applied perturbation because intrinsic error fields make the target plasma nonaxisymmetric, and suggests that at least some of the variation in ELM behavior in a single device or among different devices is due to differences in the intrinsic error fields in these devices. These results indicate that ELMs can be suppressed by small edge resonant magnetic field perturbations. Extrapolation to next-step burning plasma devices will require extending the regime of operation to

  16. [Comparative analysis of tissue reaction to acrylic resin materials in studies on Wistar strain rats].

    PubMed

    Sobolewska, E

    1999-01-01

    The study takes up the issue of assessing rat tissue reaction to operatively inserted implants of different acrylic resin materials used in prosthetic dentistry. The materials subjected to analysis were polyacrylics: Vertex Soft, Vertex R.S., Vertex S.C., Superacryl and silicone material Molloplast B. The prolongation of life and the dynamic development of prosthetic treatment have caused removable dentures to be used longer and among more people. Polymerised acrylic resin material of these dentures is a potential pathogenic factor to the oral cavity mucosa which is in contact with it. As many as 20 to 70% of patients using removable acrylic dentures suffer from prosthetic stomatopathy. It is considered that the mucosa irritation may be caused by denture trauma, a mycotic infection or toxic action of some components of acrylic materials. Therefore the use of new generation acrylic materials in producing prosthetic dentures needs a precise assessment of undesirable local and systemic effects. A comparative analysis of the effect of correctly polymerised acrylic material on rat mucosa, parotid glands and lymphatic nodes was carried out. Systemic toxicity of these materials was assessed. Acrylic plates were prepared from the most often used acrylic resin materials in the Department of Prosthetic Dentistry PAM and a silicone material (these materials were polymerised precisely according to the producers instruction). Before implantation the plates underwent a thermodynamic analysis in order to ensure that the polymerisation process was carried out correctly and to determine thermal resistance of particular materials. Next sterile acrylic plates were implanted in rats under general anaesthesia. The animals were divided into 6 groups, 10 rats each. In four groups acrylic plates were implanted, in one group silicone material plates were implanted and it represented the comparative group, in one control group an incision of the buccal mucosa was made. The rats were

  17. [Comparative analysis of tissue reaction to acrylic resin materials in studies on Wistar strain rats].

    PubMed

    Sobolewska, E

    1999-01-01

    The study takes up the issue of assessing rat tissue reaction to operatively inserted implants of different acrylic resin materials used in prosthetic dentistry. The materials subjected to analysis were polyacrylics: Vertex Soft, Vertex R.S., Vertex S.C., Superacryl and silicone material Molloplast B. The prolongation of life and the dynamic development of prosthetic treatment have caused removable dentures to be used longer and among more people. Polymerised acrylic resin material of these dentures is a potential pathogenic factor to the oral cavity mucosa which is in contact with it. As many as 20 to 70% of patients using removable acrylic dentures suffer from prosthetic stomatopathy. It is considered that the mucosa irritation may be caused by denture trauma, a mycotic infection or toxic action of some components of acrylic materials. Therefore the use of new generation acrylic materials in producing prosthetic dentures needs a precise assessment of undesirable local and systemic effects. A comparative analysis of the effect of correctly polymerised acrylic material on rat mucosa, parotid glands and lymphatic nodes was carried out. Systemic toxicity of these materials was assessed. Acrylic plates were prepared from the most often used acrylic resin materials in the Department of Prosthetic Dentistry PAM and a silicone material (these materials were polymerised precisely according to the producers instruction). Before implantation the plates underwent a thermodynamic analysis in order to ensure that the polymerisation process was carried out correctly and to determine thermal resistance of particular materials. Next sterile acrylic plates were implanted in rats under general anaesthesia. The animals were divided into 6 groups, 10 rats each. In four groups acrylic plates were implanted, in one group silicone material plates were implanted and it represented the comparative group, in one control group an incision of the buccal mucosa was made. The rats were

  18. Thermo-Optic Coefficient of Different Photosensitive Acrylate Polymers for Optical Application

    NASA Astrophysics Data System (ADS)

    Razali, N.; Mohamed, R.; Ehsan, A. A.; Kuang, C. S.; Shaari, S.

    Thermo-optic (TO) effect in materials can be exploited in the fabrication of optical devices such as optical switches and couplers. These optical devices play a key function in communication networks because by changing the temperature they have control over the optical path. Recently, polymer materials have begun to receive attention for the application of the TO switch in integrated optics. The polymers exploited for the variation of refractive index with temperature in our work involve the use of cyclomer acrylate, which is compared to the fluorinated acrylate available in the market. We focus the on cyclomer acrylate resin potential to be employed in fabricating optical devices especially the optical waveguide and optical switch. Formerly, this polymer is used as an adhesive and coating only. Different acrylate formulations from cyclomer acrylates have been exploited. Both acrylates show negative TO effects with temperature i.e. decrease of refractive index result in the increase in temperature. This is expected as the refractive index of the polymers are reduced, as density typically decreases with increasing temperature. This is in accordance to the dependence of polarizability and density of a particular material, to its refractive index. For both types of polymers, the change of the refractive index as a function of temperature is linear. The slope can give the dn/dT of the film. The dn/dT of polymers are as high as the order of 10-4, which is comparable to those of optical polymers. Higher values are shown by the cyclomer acrylate compared to the fluorinated type.

  19. Structural degradation of acrylic bone cements due to in vivo and simulated aging.

    PubMed

    Hughes, Kerry F; Ries, Michael D; Pruitt, Lisa A

    2003-05-01

    Acrylic bone cement is the primary load-bearing material used for the attachment of orthopedic devices to adjoining bone. Degradation of acrylic-based cements in vivo results in a loss of structural integrity of the bone-cement-prosthesis interface and limits the longevity of cemented orthopedic implants. The purpose of this study is to investigate the effect of in vivo aging on the structure of the acrylic bone cement and to develop an in vitro artificial aging protocol that mimics the observed degradation. Three sets of retrievals are examined in this study: Palacos brand cement retrieved from hip replacements, and Simplex brand cement retrieved from both hip and knee replacement surgeries. In vitro aging is performed using oxidative and acidic environments on three acrylic-based cements: Palacos, Simplex, and CORE. Gel permeation chromatography (GPC) and Fourier transform infrared spectroscopy (FTIR) are used to examine the evolution of molecular weight and chemical species within the acrylic cements due to both in vivo and simulated aging. GPC analysis indicates that molecular weight is degraded in the hip retrievals but not in the knee retrievals. Artificial aging in an oxidative environment best reproduces this degradation mechanism. FTIR analysis indicates that there exists a chemical evolution within the cement due to in vivo and in vitro aging. These findings are consistent with scission-based degradation schemes in the cement. Based on the results of this study, a pathway for structural degradation of acrylic bone cement is proposed. The findings from this investigation have broad applicability to acrylic-based cements and may provide guidance for the development of new bone cements that resist degradation in the body.

  20. Densified edge seals for fuel cell components

    DOEpatents

    DeCasperis, Anthony J.; Roethlein, Richard J.; Breault, Richard D.

    1982-01-01

    A porous fuel cell component, such as an electrode substrate, has a densified edge which forms an improved gas seal during operation when soaked with electrolyte. The edges are made from the same composition as the rest of the component and are made by compressing an increased thickness of this material along the edges during the fabrication process.

  1. Cytological organization of the alpha component of the anterior olfactory nucleus and olfactory limbus

    PubMed Central

    Larriva-Sahd, Jorge

    2012-01-01

    This study describes the microscopic organization of a wedge-shaped area at the intersection of the main (MOB) and accessory olfactory bulbs (AOBs), or olfactory limbus (OL), and an additional component of the anterior olfactory nucleus or alpha AON that lies underneath of the AOB. The OL consists of a modified bulbar cortex bounded anteriorly by the MOB and posteriorly by the AOB. In Nissl-stained specimens the OL differs from the MOB by a progressive, antero-posterior decrease in thickness or absence of the external plexiform, mitral/tufted cell, and granule cell layers. On cytoarchitectual grounds the OL is divided from rostral to caudal into three distinct components: a stripe of glomerular-free cortex or preolfactory area (PA), a second or necklace glomerular area, and a wedge-shaped or interstitial area (INA) crowned by the so-called modified glomeruli that appear to belong to the anterior AOB. The strategic location and interactions with the main and AOBs, together with the previously noted functional and connectional evidence, suggest that the OL may be related to both sensory modalities. The alpha component of the anterior olfactory nucleus, a slender cellular cluster (i.e., 650 × 150 μm) paralleling the base of the AOB, contains two neuron types: a pyramidal-like neuron and an interneuron. Dendrites of pyramidal-like cells (P-L) organize into a single bundle that ascends avoiding the AOB to resolve in a trigone bounded by the edge of the OL, the AOB and the dorsal part of the anterior olfactory nucleus. Utrastructurally, the neuropil of the alpha component contains three types of synaptic terminals; one of them immunoreactive to the enzyme glutamate decarboxylase, isoform 67. PMID:22754506

  2. Anterior Cervical Spine Surgery for Degenerative Disease: A Review

    PubMed Central

    SUGAWARA, Taku

    Anterior cervical spine surgery is an established surgical intervention for cervical degenerative disease and high success rate with excellent long-term outcomes have been reported. However, indications of surgical procedures for certain conditions are still controversial and severe complications to cause neurological dysfunction or deaths may occur. This review is focused mainly on five widely performed procedures by anterior approach for cervical degenerative disease; anterior cervical discectomy, anterior cervical discectomy and fusion, anterior cervical corpectomy and fusion, anterior cervical foraminotomy, and arthroplasty. Indications, procedures, outcomes, and complications of these surgeries are discussed. PMID:26119899

  3. Effect of light-curing, pressure, oxygen inhibition, and heat on shear bond strength between bis-acryl provisional restoration and bis-acryl repair materials

    PubMed Central

    Shim, Ji-Suk; Lee, Jeong-Yol; Choi, Yeon-Jo; Shin, Sang-Wan

    2015-01-01

    PURPOSE This study aimed to discover a way to increase the bond strength between bis-acryl resins, using a comparison of the shear bond strengths attained from bis-acryl resins treated with light curing, pressure, oxygen inhibition, and heat. MATERIALS AND METHODS Self-cured bis-acryl resin was used as both a base material and as a repair material. Seventy specimens were distributed into seven groups according to treatment methods: pressure - stored in a pressure cooker at 0.2 Mpa; oxygen inhibition- applied an oxygen inhibitor around the repaired material,; heat treatment - performed heat treatment in a dry oven at 60℃, 100℃, or 140℃. The shear bond strength was measured with a universal testing machine, and the shear bond strength (MPa) was calculated from the peak load of failure. A comparison of the bond strength between the repaired specimens was conducted using one-way ANOVA and Tukey multiple comparison tests (α=.05). RESULTS There were no statistically significant differences in the shear bond strength between the control group and the light curing, pressure, and oxygen inhibition groups. However, the heat treatment groups showed statistically higher bond strengths than the groups treated without heat, and the groups treated at a higher temperature resulted in higher bond strengths. Statistically significant differences were seen between groups after different degrees of heat treatment, except in groups heated at 100℃ and 140℃. CONCLUSION Strong bonding can be achieved between a bis-acryl base and bis-acryl repair material after heat treatment. PMID:25722837

  4. Low anterior resection without defunctioning stoma.

    PubMed

    Kanellos, I; Zacharakis, E; Christoforidis, E; Demetriades, H; Betsis, D

    2002-12-01

    The aim of our study was to determine the anastomotic leakage rate after the performance of low anterior resection without protective stoma. During the time period from 1989 to 2001, 82 consecutive patients underwent low anterior resection for rectal carcinoma without protective stoma. Thirteen anastomoses were hand sewn (15.8%) and the remaining 69 (84.2%) were constructed with the use of a circular stapling gun. The mean distance of the anastomoses from the anal margin was 6.2 cm (range, 3-9 cm). None of the 82 low anterior resections was covered by a defunctioning stoma. Clinical anastomotic leakage occurred in 4 patients (4.9%) and 4 other patients presented radiologically detected leakage (4.9%). No death occurred in the 8 patients that presented anastomotic dehiscence. Non-specific complications were detected in 11 (13.4%) of 82 patients. In conclusion, the low leakage rate of the anastomoses in our patients allows us to recommend low anterior resection without defunctioning stoma.

  5. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Anterior poliomyelitis. 3.379 Section 3.379 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS...

  6. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Anterior poliomyelitis. 3.379 Section 3.379 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS...

  7. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Anterior poliomyelitis. 3.379 Section 3.379 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS...

  8. Anterior Chamber Live Loa loa: Case Report.

    PubMed

    Kagmeni, G; Cheuteu, R; Bilong, Y; Wiedemann, P

    2016-01-01

    We reported a case of unusual intraocular Loa loa in a 27-year-old patient who presented with painful red eye. Biomicroscopy revealed a living and active adult worm in the anterior chamber of the right eye. After surgical extraction under local anesthesia, parasitological identification confirmed L. loa filariasis. PMID:27441005

  9. Anterior Chamber Live Loa loa: Case Report

    PubMed Central

    Kagmeni, G.; Cheuteu, R.; Bilong, Y.; Wiedemann, P.

    2016-01-01

    We reported a case of unusual intraocular Loa loa in a 27-year-old patient who presented with painful red eye. Biomicroscopy revealed a living and active adult worm in the anterior chamber of the right eye. After surgical extraction under local anesthesia, parasitological identification confirmed L. loa filariasis. PMID:27441005

  10. Causes of anterior cruciate ligament injuries.

    PubMed

    Ristić, Vladimir; Ninković, Srdan; Harhaji, Vladimir; Milankov, Miroslav

    2010-01-01

    In order to prevent anterior cruciate ligament injuries it is necessary to define risk factors and to analyze the most frequent causes of injuries--that being the aim of this study. The study sample consisted of 451 surgically treated patients, including 400 sportsmen (65% of them being active and 35% recreational sportsmen), 29% female and 71% male; of whom 90% were younger than 35. Sports injuries, as the most frequent cause of anterior cruciate ligament injuries, were recorded in 88% of patients (non-contact ones in 78% and contact ones in 22%), injuries occurring in everyday activities in 11% and in traffic in 1%. Among sportsmen, reconstruction of the anterior cruciate ligament was most frequently performed in football players (48%), then in handball players (22%), basketball players (13%), volleyball players (8%), martial arts fighters (4%). However, the injury incidence was the highest among the active basketball players (1 injured among 91 active players). Type of footwear, warming up before the activity, genetic predisposition and everyday therapy did not have a significant influence on getting injured. Anterior cruciate ligament injuries happened three times more often during matches, in the middle and at the end of a match and training session (79%), at landing after the jump or when changing direction of movement (75%) without a contact with other competitors, on dry surfaces (79%), among not so well prepared sportsmen.

  11. K-edge densitometer (KED)

    SciTech Connect

    Sprinkle, J.K.; Hansen, W.J.

    1993-02-11

    In 1979, a K-edge densitometer (KED) was installed by the Safeguards Assay group from Los Alamos National Laboratory in the PNC reprocessing plant at Tokai-mura, Japan. It uses an active nondestructive assay technique, KED, to measure the plutonium concentration of the product solution. The measurement uncertainty of an assay depends on the count time chosen, but can be 0.5% or better. The computer hardware and software were upgraded in 1992. This manual describes the operation of the instrument, with an emphasis on the user interface to the software.

  12. An Efficient Ant-Based Edge Detector

    NASA Astrophysics Data System (ADS)

    Aydın, Doğan

    An efficient ant-based edge detector is presented. It is based on the distribution of ants on an image, ants try to find possible edges by using a state transition function based on 5x5 edge structures. Visual comparisons show that the proposed method gives finer details and thinner edges at lesser computational times when compared to earlier ant-based approaches. When compared to standard edge detectors, it shows robustness to Gaussian and Salt & Pepper noise and provides finer details than others with same parameter set in both clear and noisy images.

  13. Tunable skewed edges in puckered structures

    NASA Astrophysics Data System (ADS)

    Grujić, Marko M.; Ezawa, Motohiko; Tadić, Milan Ž.; Peeters, François M.

    2016-06-01

    We propose a type of edges arising due to the anisotropy inherent in the puckered structure of a honeycomb system such as in phosphorene. Skewed-zigzag and skewed-armchair nanoribbons are semiconducting and metallic, respectively, in contrast to their normal edge counterparts. Their band structures are tunable, and a metal-insulator transition is induced by an electric field. We predict a field-effect transistor based on the edge states in skewed-armchair nanoribbons, where the edge state is gapped by applying arbitrary small electric field Ez. A topological argument is presented, revealing the condition for the emergence of such edge states.

  14. The effect of various frequencies of ultrasonic cleaner in reducing residual monomer in acrylic resin.

    PubMed

    Charasseangpaisarn, Taksid; Wiwatwarrapan, Chairat

    2015-12-01

    Monomer remaining in denture base acrylic can be a major problem because it may cause adverse effects on oral tissue and on the properties of the material. The purpose of this study was to compare the effect of various ultrasonic cleaner frequencies on the amount of residual monomer in acrylic resin after curing. Forty-two specimens each of Meliodent heat-polymerized acrylic resin (M) and Unifast Trad Ivory auto-polymerized acrylic resin (U) were prepared according to their manufacturer's instructions and randomly divided into seven groups: Negative control (NC); Positive control (PC); and five ultrasonic treatment groups: 28 kHz (F1), 40 kHz (F2), 60 kHz (F3) (M=10 min, U=5 min), and 28 kHz followed by 60 kHz (F4: M=5 min per frequency, U=2.5 min per frequency, and F5: M=10 min followed by 5 min per frequency, U=5 min followed by 2.5 min per frequency). Residual monomer was determined by HPLC following ISO 20795-1. The data were analyzed by One-way ANOVA and Tukey HSD. There was significantly less residual monomer in the auto-polymerized acrylic resin in all ultrasonic treatment groups and the PC group than that of the NC group (p<0.05). However, the amount of residual monomer in group F3 was significantly higher than that of the F1, F4, and PC groups (p<0.05). In contrast, ultrasonic treatment did not reduce the amount of residual monomer in heat-polymerized acrylic resin (p>0.05). The amount of residual monomer in heat-polymerized acrylic resin was significantly lower than that of auto-polymerized acrylic resin. In conclusion, ultrasonic treatment at low frequencies is recommended to reduce the residual monomer in auto-polymerized acrylic resin and this method is more practical in a clinical situation than previously recommended methods because of reduced chairside time.

  15. Using Particle Imaging Velocimetry to Measure Anterior-Posterior Velocity Gradients in the Excised Canine Larynx Model

    PubMed Central

    Khosla, Sid; Murugappan, Shanmugam; Lakhamraju, Raghavaraju; Gutmark, Ephraim

    2008-01-01

    Objectives To quantify the anterior-posterior velocity gradient, we studied the velocity flow fields above the vocal folds in both the midcoronal and midsagittal planes. It was also our purpose to use these fields to deduce the mechanisms that cause the anterior-posterior gradient and to determine whether the vortical structures are highly 3-dimensional. Methods Using the particle imaging velocimetry method for 5 excised canine larynges. we obtained phase-averaged velocity fields in the midcoronal and midsagittal planes for 30 phases of phonation. The velocity fields were determined synchronously with the vocal fold motion recorded by high-speed videography. Results The results show that immediately above the folds, there is no significant anterior-posterior velocity gradient. However, as the flow travels downstream, the laryngeal jet tends to narrow in width and skew toward the anterior commissure. Vortices are seen at the anterior and posterior edges of the flow. Conclusions The downstream narrowing in the midsagittal plane is consistent with and is probably due to a phenomenon known as axis switching. Axis switching also involves vortices in the sagittal and coronal planes bending in the axial plane. This results in highly 3-dimensional, complex vortical structures. However, there is remarkable cyclic repeatability of these vortices during a phonation cycle. PMID:18357838

  16. Effect of different palatal vault shapes on the dimensional stability of glass fiber-reinforced heat-polymerized acrylic resin denture base material

    PubMed Central

    Dalkiz, Mehmet; Arslan, Demet; Tuncdemir, Ali Riza; Bilgin, M.Selim; Aykul, Halil

    2012-01-01

    Objective: The aim of this study was to determine the effect of different palatal vault shapes on the dimensional stability of a glass fiber reinforced heat polymerized acrylic resin denture base material. Methods: Three edentulous maxilla with shallow, deep and medium shaped palatal vaults were selected and elastomeric impressions were obtained. A maxillary cast with four reference points (A, B, C, and D) was prepared to serve as control. Point (A) was marked in the anterior midline of the edentulous ridge in the incisive papillary region, points (B) and (C) were marked in the right and left posterior midlines of the edentulous ridge in the second molar regions, and point (D) was marked in the posterior palatal midline near the fovea palatina media (Figure 2). To determine linear dimensional changes, distances between four reference points (A–B, A–C, A–D and B–C) were initially measured with a metal gauge accurate within 0.1 mm under a binocular stereo light microscope and data (mm) were recorded. Results: No significant difference of interfacial distance was found in sagittal and frontal sections measured 24 h after polymerization and after 30 days of water storage in any of experimental groups (P>.05). Significant difference of linear dimension were found in all experimental groups (P<.01) between measurements made 24 h after polymerization of specimens and 30 days after water storage. Conclusion: Palatal vault shape and fiber impregnation into the acrylic resin bases did not affect the magnitude of interfacial gaps between the bases and the stone cast surfaces. PMID:22229010

  17. Glubran 2: A New Acrylic Glue for Neuroradiological Endovascular Use

    PubMed Central

    Leonardi, M.; Barbara, C.; Simonetti, L.; Giardino, R.; Nicoli Aldini, N.; Fini, M.; Martini, L.; Masetti, L.; Joechler, M.; Roncaroli, F.

    2002-01-01

    Summary A new acrylic glue, Glubran 2, is now available on the European market. It bears the CE mark with several surgical indications and the specific indication for neuroradiological endovascular use. Despite this approval, to our knowledge its use is still limited to surgery and no injections have been made in human patients. This study was designed to evaluate the behavior of Glubran 2 in endovascular injection in a simulation of brain AVM. Six sheep were operated on opening a fistula between the right common carotid artery and the jugular vein. This fistula modifies blood flow in the skull base rete mirabilis, which then functions as an AVM. In two sheep, the rete mirabilis was occluded by injection of 1.5 ml of Histoacryl diluted 1:1 and 1:3 with Lipiodol. In two sheep, the rete was embolized by injection of 1.5 ml of Glubran 2 diluted 1:1 with Lipiodol. The last two sheep were embolized by injection of Glubran 2 diluted 1:3 with Lipiodol. The procedures were documented by DSA angiographic acquisitions and by fluoroscopic VHS. The sheep were killed immediately after the procedures and the rete mirabilis isolated for histologic examination. Embolization was obtained with both kinds of glue. Glubran 2 diffuses in a very similar way to Histoacryl with an apparently more complete diffusion. Reflux in the ascending pharyngeal artery showed that Glubran 2 tended not to produce bubbles but diffused more homogeneously. The subjective conclusion of this work is that Glubran 2 can be used in endovascular embolizations. Before approaching brain AVMs, a further study will investigate embolization of the external carotid territory. PMID:20594482

  18. Hemocompatibility of Chitosan/poly(acrylic acid) Grafted Polyurethane Tubing

    PubMed Central

    Lee, Hyun-Su; Tomczyk, Nancy; Kandel, Judith; Composto, Russell J.; Eckmann, David M.

    2013-01-01

    The activation and adhesion of platelets or whole blood exposed to chitosan (CH) grafted surfaces is used to evaluate the hemocompatibility of biomaterials. The biomaterial surfaces are polyurethane (PU) tubes grafted with an inner poly(acrylic acid) (PAA) and an outer CH or quaternary ammonium modified CH (CH-Q) brush. The CH, CH-Q and PAA grafted layers were characterized by ellipsometry and fluorescence microscopy. Material wear tests demonstrate that CH (CH-Q) is stably grafted onto PU tubes upon exposure to saline solution for 7 days. Using quartz-crystal microbalances with dissipation (QCM-D), in-situ adsorption of blood plasma proteins on CH and CH-Q compared to a silicon oxide control was measured. The QCM-D results showed that the physically adsorbed plasma protein layer on CH-Q and CH surfaces is softer and more viscous than the protein layer on the SiO2 surface. The CH-Q layer thus has the weakest interaction with plasma proteins. Whole blood and platelet adhesion was reduced by ~92% on CH-Q, which showed the weakest interaction with plasma protein but more viscous adsorbed plasma protein layer, compared to SiO2. Last, to examine the biologic response of platelets and neutrophils to biomaterial surfaces, CH (CH-Q)/PAA, PAA and PU tubes were tested using a Chandler Loop apparatus as an ex vivo model and flow cytometry. The blood adhesion and biologic response results showed that CH and CH-Q reduced adhesion and activation of platelets and neutrophils and improved hemocompatibility relative to other surfaces (PU and PAA). Our studies demonstrated that the properties of physically adsorbed plasma protein layer on biomaterial surfaces correlates with blood coagulation on biomaterial surfaces. PMID:24349719

  19. Comparison of impact strength of acrylic resin reinforced with kevlar and polyethylene fibres.

    PubMed

    Kamath, G; Bhargava, K

    2002-01-01

    The present study was done to evaluate the impact strengths of heat-activated acrylic resins reinforced with Kevlar fibres, polyethylene fibres and unreinforced heat activated acrylic resin. Each of three groups had 25 specimens. Brass rods of uniform length of 40 mm and diameter of 8 mm were used to prepare the moulds. A combination of long fibres (40 mm length) and short fibres (6 mm length) were used. The total amount of fibres incorporated was limited to 2% by weight of the resin matrix. Short and long fibres of equal weight were incorporated. The short fibres were mixed with polymer and monomer and packed into the mould, while, the long axis of the specimen, perpendicular to the applied force. The specimens were then processed. Impact strength testing was done on Hounsfield's impact testing machine. Kevlar fibre reinforced heat activated acrylic resin specimens recorded higher mean impact strength of 0.8464 Joules, while polyethylene fibres reinforced heat activated acrylic resin recorded mean impact strength of 0.7596 joules. The unreinforced heat activated acrylic resin recorded mean impact strength of 0.3440 Joules.

  20. Synthesis of a novel acrylated abietic acid-g-bacterial cellulose hydrogel by gamma irradiation.

    PubMed

    Abeer, Muhammad Mustafa; Amin, Mohd Cairul Iqbal Mohd; Lazim, Azwan Mat; Pandey, Manisha; Martin, Claire

    2014-09-22

    Acrylated abietic acid (acrylated AbA) and acrylated abietic acid-grafted bacterial cellulose pH sensitive hydrogel (acrylated AbA-g-BC) were prepared by a one-pot synthesis. The successful dimerization of acrylic acid (AA) and abietic acid (AbA) and grafting of the dimer onto bacterial cellulose (BC) was confirmed by 13C solid state NMR as well as FT-IR. X-ray diffraction analysis showed characteristic peaks for AbA and BC; further, there was no effect of increasing amorphous AA content on the overall crystallinity of the hydrogel. Differential scanning calorimetry revealed a glass transition temperature of 80°C. Gel fraction and swelling studies gave insight into the features of the hydrogel, suggesting that it was suitable for future applications such as drug delivery. Scanning electron microscopy observations showed an interesting interpenetrating network within the walls of hydrogel samples with the lowest levels of AA and gamma radiation doses. Cell viability test revealed that the synthesized hydrogel is safe for future use in biomedical applications.