Science.gov

Sample records for anterior edge acrylic

  1. Pathologic comparison of asymmetric or sulcus fixation of 3-piece intraocular lenses with square versus round anterior optic edges

    PubMed Central

    Ollerton, Andrew; Werner, Liliana; Strenk, Susan; Strenk, Lawrence; Leishman, Lisa; Bodnar, Zachary; Kirk, Kevin R; Michelson, Jennifer; Mamalis, Nick

    2013-01-01

    Objective To evaluate pathologic findings of 3-piece intraocular lenses (IOLs) with asymmetric or sulcus fixation in pseudophakic cadaver eyes, comparing IOLs with square or round edges on the anterior optic surface. Design Comparative case series with pathology. Participants 661 pseudophakic cadaver eyes obtained from eye banks within the United States, implanted with different IOLs Methods Anterior segment scanning of whole eyes with a high-frequency ultrasound system, or with a high-resolution anterior segment magnetic resonance imaging, followed by gross examination. Selected eyes were processed for complete histopathologic analysis. Main Outcome Measures Findings from imaging, gross, and histopathologic evaluation that could be related to out-of-the-bag fixation of the lenses. Results Out of 661 pseudophakic cadaver eyes obtained, 13 had 3-piece hydrophobic acrylic IOLs with anterior and posterior square optic edges, and 14 had 3-piece lenses with anterior round edges (13 silicone lenses, and 1 hydrophobic acrylic lens) without symmetric in-the-bag fixation. These 27 selected eyes were processed for complete histopathologic analysis. Gross findings in both groups were composed of IOL decentration and tilt, pigmentary dispersion within the anterior segment and on the IOL surface, and iris transillumination defects. Histopathology of the 14 eyes with 3-piece IOLs with round anterior optic edges showed mild focal disruption of the iris pigmented layer, and loop protrusion/erosion in the ciliary sulcus. Additional changes observed in the 13 eyes with square anterior optic edge IOLs included iris changes such as vacuolization, disruption and loss of the pigmented epithelial layers, iris thinning and atrophy, synechiae, and pigmentary dispersion within the trabecular meshwork. One eye also exhibited initial signs of optic nerve disc cupping. Conclusion In this series, pathologic findings were more severe in eyes implanted with 3-piece IOLs with square anterior optic

  2. Pathologic comparison of asymmetric or sulcus fixation of 3-piece intraocular lenses with square versus round anterior optic edges.

    PubMed

    Ollerton, Andrew; Werner, Liliana; Strenk, Susan; Strenk, Lawrence; Leishman, Lisa; Bodnar, Zachary; Kirk, Kevin R; Michelson, Jennifer; Mamalis, Nick

    2013-08-01

    To evaluate the pathologic findings of 3-piece intraocular lenses (IOLs) with asymmetric or sulcus fixation in pseudophakic cadaver eyes, comparing IOLs with square or round edges on the anterior optic surface. Comparative case series with pathology. A total of 661 pseudophakic cadaver eyes, obtained from eye banks within the United States, implanted with different IOLs. Anterior segment scanning of whole eyes with a high-frequency ultrasound system or high-resolution anterior segment magnetic resonance imaging followed by gross examination. Selected eyes were processed for complete histopathologic analysis. Findings from imaging, gross, and histopathologic evaluation that could be related to out-of-the-bag fixation of the lenses. Of 661 pseudophakic cadaver eyes obtained, 13 had 3-piece hydrophobic acrylic IOLs with anterior and posterior square optic edges, and 14 had 3-piece lenses with anterior round edges (13 silicone lenses and 1 hydrophobic acrylic lens) without symmetric in-the-bag fixation. These 27 selected eyes were processed for complete histopathologic analysis. Gross findings in both groups were composed of IOL decentration and tilt, pigmentary dispersion within the anterior segment and on the IOL surface, and iris transillumination defects. Histopathology of the 14 eyes with 3-piece IOLs with round anterior optic edges showed mild focal disruption of the iris pigmented layer and loop protrusion/erosion in the ciliary sulcus. Additional changes observed in the 13 eyes with square anterior optic edge IOLs included iris changes, such as vacuolization, disruption and loss of the pigmented epithelial layers, iris thinning and atrophy, synechiae, and pigmentary dispersion within the trabecular meshwork. One eye also exhibited initial signs of optic nerve disc cupping. In this series, pathologic findings were more severe in eyes implanted with 3-piece IOLs with square anterior optic edges, suggesting that IOLs with round anterior edges are more suitable for

  3. Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: effect on posterior capsule opacification.

    PubMed

    Iwase, Takeshi; Nishi, Yutarou; Oveson, Brian C; Jo, Young-Joon

    2011-06-01

    To evaluate posterior capsule opacification (PCO) 2 years after cataract surgery with implantation of a hydrophobic acrylic or single-piece sharp-edged hydrophilic acrylic intraocular lens (IOL). Toyama Prefectural Central Hospital, Toyama, Japan. Case-control study. Patients with bilateral senile cataract were prospectively randomized to receive a hydrophobic IOL (Acrysof SA60AT) in 1 eye and a hydrophilic IOL (Meridian HP60M) in the other eye. The PCO density value, degree of IOL decentration and tilt, and anterior chamber depth (ACD) were measured using Scheimpflug videophotography 1, 6, 12, 18, and 24 months after surgery. Visual acuity and the number of eyes requiring neodymium:YAG laser capsulotomy were also assessed. The study evaluated 16 eyes (63 patients). The PCO value in the hydrophilic group increased significantly with time and was statistically significantly greater than in the hydrophobic group 18 and 24 months postoperatively (both P < .001). The capsulotomy rate was statistically significantly higher in the hydrophilic group than in the hydrophobic group (P < .01). Visual acuity in the hydrophilic group worsened significantly with time and was statistically significantly worse than in the hydrophobic group at 18 and 24 months (both P < .001). Intraocular lens decentration, IOL tilt, and the ACD did not change significantly during the follow-up in either group (P > .05), and there were no statistically significant postoperative differences in these parameters between the 2 IOL groups (P > .05). Two years after surgery, the hydrophobic IOL group had less PCO, a lower capsulotomy rate, and better visual acuity than the hydrophilic IOL group. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Nd:YAG laser capsulotomy rates following implantation of square-edged intraocular lenses: polymethyl methacrylate versus silicone versus acrylic.

    PubMed

    Ram, Jagat; Kumar, Sunil; Sukhija, Jaspreet; Severia, Saurabh

    2009-04-01

    To study the influence of square-edged intraocular lenses (IOLs) on the development of posterior capsule opacification (PCO) and the requirement for laser capsulotomy. Retrospective study. Three hundred seventy-seven eyes of 377 patients were included. All these patients underwent phacoemulsification and implantation of square polymethyl methacrylate (PMMA) (Aurolab), silicone (Tecnis Z9000), acrylic hydrophobic (AcrySof MA60AC and Sensar Optiedge), or acrylic hydrophilic (Akreos Adapt) IOLs with a minimum of 2 years' follow-up. Only those cases in which Nd:YAG laser capsulotomy had been performed for visually significant PCO were evaluated. Three hundred seventy-seven eyes of 377 patients were included in the study. Follow-up duration ranged from 24 to 54 (mean 40.27, SD 8.42) months. The incidence of PCO requiring Nd:YAG laser capsulotomy was found to be significantly less in the silicone lens group: 1.4% as compared with an incidence of 11.7% in the PMMA lens group (p = 0.018). In the square-edged acrylic group, visually significant PCO requiring Nd:YAG laser capsulotomy was observed in 3.6%, 4.8%, and 6.8% of eyes implanted with AcrySof MA60AC, Sensar Optiedge, and Akreos Adapt IOLs, respectively. In 5 of the 7 eyes (71.4%) exhibiting PCO in the PMMA group, the condition developed within the first 6 months. In the silicone and acrylic group, development of PCO was delayed. The rate of visually significant PCO as well as the need for Nd:YAG laser capsulotomy is influenced by IOL biomaterial in addition to square edge. It is significantly delayed with square-edged foldable acrylic and silicone IOLs compared with square-edged PMMA IOLs.

  5. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients

    PubMed Central

    Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng

    2015-01-01

    AIM To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. METHODS Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. RESULTS There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. CONCLUSION For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. PMID:26309870

  6. Tricuspid Anterior Leaflet Replacement with Autologous Pericardium and Polytetrafluoroethylene Chordae, Followed by Edge-to-Edge Repair

    PubMed Central

    García-Rinaldi, Raúl

    2007-01-01

    Treatment of endocarditis of the tricuspid valve is very complex. Valvectomy without replacement can result in significant postoperative morbidity, and replacement is hazardous due to the possibility of prosthetic infection. Repair of the tricuspid valve is the best alternative. Many ingenious methods have been devised to repair the tricuspid valve in patients with infective endocarditis. However, repair of the endocarditic anterior leaflet presents a difficult surgical problem. We have developed a technique to replace the central portion of the anterior leaflet, in which most of the leaflet is excised and replaced with autologous pericardium. By preserving a small rim of the leaflet, we preserve the lateral and medial chordal attachments. Supplemental neochordae are created with polytetrafluoroethylene sutures. An edge-to-edge repair is used to correct residual insufficiency of the valve. We have used this technique in 4 patients. One patient died 1 month after surgery, but with a competent tricuspid valve. Three patients are now alive, 48, 34, and 1.5 months after surgery. Their tricuspid valves are functional, moving well, and competent. We conclude that the centrally infected anterior leaflet of the tricuspid valve can be replaced with autologous pericardium. The implantation of polytetrafluoroethylene neochordae and edge-to-edge repair can be used to achieve valve competence. Short- and medium-term follow-up in patients who have been treated with these techniques demonstrates that the valve remains fully mobile and competent. PMID:17948081

  7. Regional divergence of palate medial edge epithelium along the anterior to posterior axis.

    PubMed

    Jin, Jiu-Zhen; Warner, Dennis R; Ding, Jixiang

    2014-01-01

    Recent studies have shown that mouse palatal mesenchymal cells undergo regional specification along the anterior-posterior (A-P) axis defined by anterior Shox2 and Msx1 expression and posterior Meox2 expression. A-P regional specification of the medial edge epithelium, which is directly responsible for palate fusion, has long been proposed, but it has not yet been demonstrated due to the lack of regional specific markers. In this study, we have demonstrated that the palate medial edge epithelium is regionalized along the A-P axis, similar to that for the underlying mesenchyme. Mmp13, a medial edge epithelium specific marker, was uniformly expressed from anterior to posterior in wild-type mouse palatal shelves. Previous studies demonstrated that medial edge epithelium expression of Mmp13 was regulated by TGF-beta3. We have found that the changes in Mmp13 expression in TGF-beta3 knockouts varied along the A-P axis, and can be broken down into three distinct regions. These regions correlated with regional specification of the underlying medial edge mesenchymal cells and timing of palate fusion. Mouse palate medial edge epithelium along the A-P axis can be divided into different regions according to the differential response to the loss of TGF-beta3.

  8. UV-assisted treatment on hydrophobic acrylic IOLs anterior surface with methacryloyloxyethyl phosphorylcholine: Reducing inflammation and maintaining low posterior capsular opacification properties.

    PubMed

    Huang, Xiaodan; Luo, Chenqi; Lin, Lin; Zhang, Li; Li, Heyi; Yao, Ke; Xu, Zhikang

    2017-06-01

    In order to enhance the surface biocompatibility of hydrophobic acrylic intraocular lenses (IOLs), the anterior surface was modified through graft polymerization with methacryloyloxyethyl phosphorylcholine (MPC) initiated by ultraviolet radiation. Chemical changes on the IOL surface were characterised by X-ray photoelectron spectroscopy (XPS) to confirm the covalent binding of MPC. Field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) analysis were used to characterise the morphological changes to the IOL surface. Static water contact angle (WCA) measurements showed that the hydrophilicity of the anterior surface was enhanced after grafting with MPC. The surface biocompatibility of the untreated and Anterior UV-MPC IOLs was compared with the adhesion behaviour of macrophages in vitro. The degree of posterior capsule opacification (PCO) of untreated, anterior treated, and posterior treated IOLs was evaluated by observing the behaviour of lens epithelial cells (LECs) between the IOL optic portion and type IV collagen. Results suggest that the MPC modified anterior surface resisted the attachment of macrophages. However, MPC grafted onto the posterior surface enhanced the migration of LECs between the IOL optic and type IV collagen, which may result in severe PCO. In conclusion, our Anterior UV-MPC IOLs may reduce postoperative inflammation while maintaining the low PCO rates of hydrophobic acrylic IOLs. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Discrepancies in measuring acetabular coverage: revisiting the anterior and lateral center edge angles.

    PubMed

    Hanson, Joey A; Kapron, Ashley L; Swenson, Kathryn M; Maak, Travis G; Peters, Christopher L; Aoki, Stephen K

    2015-10-01

    The lateral center edge angle (LCEA) and the anterior center edge angle (ACEA) are commonly used to assess acetabular coverage of the femoral head. There are two distinct methods found in the literature to obtain these angles, specifically, measuring to the most lateral bone edge versus the sclerotic lateral sourcil edge. A difference between these two methods may contribute to inconsistent estimates of acetabular coverage, and potentially lead to clinical misdiagnosis and treatment mismanagement. The objectives of this study were to quantify the difference between bone edge and sourcil edge measurements and to determine how the difference influences the classification of acetabular coverage in adult patients with suspected hip pathomorphology. Two observers completed the measurements independently using preoperative anteroposterior and false profile radiographs. Bland-Altman plots and paired t-tests were used to compare measurement methods. Bone and sourcil measurements of the LCEA and ACEA were significantly different (both P < 0.001). On average, the bone LCEA was 4° (95% limits of agreement = -2° to 10°) greater than the sourcil LCEA. The bone ACEA was, on average, 10° (95% limit of agreement = -2° to 22°) greater than the sourcil ACEA. The differences often led to different clinical classifications for the same hip. With a statistically and clinically significant difference in the quantification of acetabular coverage using bone edge versus sourcil edge methods for measuring the LCEA and ACEA in adult patients, it should be mandatory to clearly identify which method was used in each study.

  10. Determining the distance from the lingual frenum anterior attachment to the lower incisors' incisal edges.

    PubMed

    Mahboub, Farhang; Kimyai, Soodabeh; Molavi, Elahe

    2016-01-01

    Background. Occlusal rims are used to determine the jaw relationships in the transverse and vertical dimensions and estimate the inter-occlusal distance in edentulous patients. It is important to find ways to determine the height and shape of the occlusal rims correctly. This study was undertaken to determine the exact distance from the oral cavity floor to the incisal edges of mandibular incisors to serve as a guide for adjusting the height of the mandibular occlusal rim. Methods. Forty patients were selected and special trays were fabricated to prepare accurate stone casts on which the measurements were made at 0.01-mm accuracy. Two marks were placed on the casts at the incisal edges of mandibular incisors and at anterior attachment of lingual frenum. Then the distance between these two marks was determined on the vertical spindle of a surveyor using a digital Vernier measuring tool and recorded. Results. The results showed that the mean and standard deviation of the distances between the oral cavity floor and the incisal edges of lower incisors were 14.35 ± 1.68 mm, with a range of 10.2‒17.02 mm. The mean distances in males and females were 15.42 ± 0.97 and 13.28 ± 1.57 mm, respectively. T-test showed significant differences in this distance between males and females, with greater distances in males. Conclusion. The distance between the oral cavity floor and the incisal edges of mandibular incisors at anterior attachment of lingual frenum might be a proper criterion for the initial adjustment of occlusal rims.

  11. Determining the distance from the lingual frenum anterior attachment to the lower incisors’ incisal edges

    PubMed Central

    Mahboub, Farhang; Kimyai, Soodabeh; Molavi, Elahe

    2016-01-01

    Background. Occlusal rims are used to determine the jaw relationships in the transverse and vertical dimensions and estimate the inter-occlusal distance in edentulous patients. It is important to find ways to determine the height and shape of the occlusal rims correctly. This study was undertaken to determine the exact distance from the oral cavity floor to the incisal edges of mandibular incisors to serve as a guide for adjusting the height of the mandibular occlusal rim. Methods. Forty patients were selected and special trays were fabricated to prepare accurate stone casts on which the measurements were made at 0.01-mm accuracy. Two marks were placed on the casts at the incisal edges of mandibular incisors and at anterior attachment of lingual frenum. Then the distance between these two marks was determined on the vertical spindle of a surveyor using a digital Vernier measuring tool and recorded. Results. The results showed that the mean and standard deviation of the distances between the oral cavity floor and the incisal edges of lower incisors were 14.35 ± 1.68 mm, with a range of 10.2‒17.02 mm. The mean distances in males and females were 15.42 ± 0.97 and 13.28 ± 1.57 mm, respectively. T-test showed significant differences in this distance between males and females, with greater distances in males. Conclusion. The distance between the oral cavity floor and the incisal edges of mandibular incisors at anterior attachment of lingual frenum might be a proper criterion for the initial adjustment of occlusal rims. PMID:28096953

  12. Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design

    PubMed Central

    Yang, Soonwon; Lim, Sung A; Na, Kyung-Sun

    2017-01-01

    Purpose To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. Methods One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic IOL (n = 97), or a plate-haptic IOL (n = 89). The area of the anterior capsule opening, IOL decentration, and capsule overlap were measured using retroillumination photospot 1 day and 2 months after cataract surgery. Results The area of capsule opening at postoperative day 1 was significantly different between the three IOLs (p < 0.01). All IOLs showed reduction of the anterior capsule opening from 1 day to 2 months after surgery, and greater reduction was shown in the modified C-haptic IOL (p < 0.001). At postoperative month 2, IOL decentration was significantly different between the IOLs and showed a positive correlation with the mean area reduction during month 2. Conclusions The degree of anterior capsule contraction and IOL decentration in modified L-haptic IOLs were less than those in modified C-haptic IOLs and comparable to those in plate-haptic IOLs. PMID:28243021

  13. Edge-to-Edge Technique to Minimize Ovelapping of Multiple Bioresorbable Scaffolds Plus Drug Eluting Stents in Revascularization of Long Diffuse Left Anterior Descending Coronary Artery Disease.

    PubMed

    Rigatelli, Gianluca; Avvocata, Fabio Dell'; Ronco, Federico; Giordan, Massimo; Roncon, Loris; Caprioglio, Francesco; Grassi, Giuseppe; Faggian, Giuseppe; Cardaioli, Paolo

    2016-06-01

    Implantation of Drug Eluting Stents (DES) plus bioresorbable scaffolds (BVS) in very long diffuse left anterior descending coronary artery (LAD) disease may be problematic because of multiple devices overlapping. We sought to assess the short and mid-tern outcomes of combined implantation of DES and BVS using a novel "edge-to-edge" technique in patients with diffuse LAD disease. Patients with long diffuse LAD disease were enrolled in a prospective registry from 1st August 2014 to 1st August 2015 and treated with IVUS-aided percutaneous coronary intervention using a DES plus a single or multiple BVS using a novel "edge-to-edge" technique. Clinical follow up and invasive follow up driven by clinical justification was performed. Twenty-three patients (5 females, mean age 59.1± 9.1 years) were enrolled. Mean length of LAD disease was 73.1 ± 20.6 mm. Mean number of DES and BVS implanted was 1.2 ± 0.4 and 1.7 ± 1.3, respectively. At a mean follow-up of 11.3 ± 3.8 months, no stent thrombosis or MACE were observed. Angiographic and IVUS follow-up at a mean of 6.6 ± 0.7 months showed no significant angiographic restenosis and no appreciable stent gaps. In revascularization of long diffuse disease of the LAD, the edge-to-edge implantation technique appears to be feasible resulting in no restenosis or thrombosis on the short-term follow-up. (J Interven Cardiol 2016;29:275-284). © 2016, Wiley Periodicals, Inc.

  14. Evaluation of Proportion between Incisal Edge to Gingival Zenith Distance and Interdental Papilla in Maxillary Anterior Dentition of Indian Population

    PubMed Central

    Damodaran, Anand; Balasubramanium, Muthukumar

    2016-01-01

    Introduction Not many investigations have evaluated the relationship between the height of the interdental papillae, gingival zenith and maxillary anterior teeth. The assessment of these parameters can aid in fabricating definitive aesthetic restoration. Aim The aim of this study was to evaluate the existence of proportional ratio between the incisal edge to gingival zenith (HGZ) and the tip of the interdental papilla (HIP) in maxillary anterior teeth for Indian population. Materials and Methods One hundred healthy volunteers with an average age of 25-30 years comprised the evaluation group. Impression was made using irreversible hydrocolloid impression material and type IV Dental stone cast was made. A calibrated digital caliper measured the distance between HGZ and HIP. The values for all six maxillary teeth were recorded and the proportional ratio was evaluated and statistically analysed. Results The mean ratio between HGZ and HIP of all maxillary anteriors in 1st and 2nd quadrant was 1.80, 1.71, and 2.03 in central incisor, lateral incisor and canine respectively with p-value > 0.9. Conclusion The mean proportional measurements for maxillary anterior teeth were determined and no definitive proportion existed between HGZ and HIP of maxillary anterior teeth. PMID:27134999

  15. [Orthodontic treatment of overbite by the Tip Edge technique in conjunction with an anterior bite elevator. Part 1].

    PubMed

    Bolendeŕ, C J

    2001-12-01

    In orthodontics, incisor overbite has always been considered as an anomaly difficult to correct but also as the one most hindering the solving of the problems resulting from other associated malpositions. The recent concept of unlocking, introduced by the bioprogressive School, proves that the profession has become aware of its importance in any orthodontic treatment plan. Due to the fact that overbite also hinders the setting up of inferior brackets or forces the practitioner to bond them in a position liable to burden the parodontal health of the lower incisors has therefore induced the author to put in place, at the beginning of the treatment with the Tip-Edge technique, an anterior bite raiser thus generating space in the lateral sectors. Considering how fast the anterior problem is solved once the occlusion is lifted, the bite raiser can be suppressed within three months. Another advantage resides in the possible adjunction of an expansion screw also aimed at unlocking the occlusion in transverse direction. The question then raised in to know whether that approach which ought to be compared to the one of the functional appliances is not the ideal solution to unlock the occlusion in the three dimensions of space when the use of fixed appliances alone might be unsuitable or too slow, regarding current therapeutic aims. Attributing that spectacular therapeutic result to an incisor intrusion or a molar extrusion is of little interest as far as those alterations do not lead to an increase of the vertical dimension of the lower portion of the face. A cephalometric study, published concomitantly, has evidenced that the use of an anterior bite raiser together with the Tip-Edge technique only leads to perfectly similar alterations to those observed with the Ricketts bioprogressive technique or the Schudy edgewise technique, without the help of a bite raiser. From now on, integrating the bite raiser in our therapeutic armamentarium in conjunction with fixed techniques

  16. Cantilever Lengths and Anterior-Posterior Spreads of Interim, Acrylic Resin, Full-Arch Screw-Retained Prostheses and Their Relationship to Prosthetic Complications.

    PubMed

    Drago, Carl

    2017-08-01

    To retrospectively record the distal cantilever lengths (CL) of full-arch interim, all-acrylic resin prostheses used in an immediate occlusal loading protocol. Anterior/posterior (A/P) spreads were measured on master casts associated with the interim prostheses. Ratios were calculated (CL/AP). Prosthetic complications were recorded. The ratios and prosthetic complications were statistically compared and analyzed for statistical and clinical significance. One hundred twenty-eight patients with 192 edentulous arches (109 maxillary; 83 mandibular; 190 arches were restored with 4 implants; 2 maxillary arches were restored with 5 implants) were treated. Seven hundred seventy implants (Brånemark System) from September 1, 2011, until August 31, 2013 were included in this report. Patients were treated and followed in a single private practice for up to 40 months. Implants had to have at least 35 Ncm of insertion torque to be immediately loaded. All implants were immediately loaded with full functional occlusions on the day the implants were placed. Interim, full-arch, all-acrylic resin prostheses were fabricated and placed into full functional occlusion following an All-on-Four protocol. Measurements of the distal cantilevered segments were made on the prostheses prior to insertion. A/P spreads were measured on the master casts made from abutment level impressions made on the day of surgery. Prosthetic complications (denture base fracture, cohesive/adhesive denture tooth fractures) were recorded in the charts as they occurred. All charts were reviewed for this report; no patients were lost to follow-up. Interim prosthetic repairs were analyzed by type (tooth or denture base), arch, gender, and location within the edentulous arches. One patient experienced complete maxillary implant failure; the overall implant survival rate (SR) was 99.5% (766 of 770). Four hundred thirty of 434 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1 and 100

  17. Acrylic acid

    Integrated Risk Information System (IRIS)

    Acrylic acid ( CASRN 79 - 10 - 7 ) Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff

  18. Methyl acrylate

    Integrated Risk Information System (IRIS)

    Methyl acrylate ; CASRN 96 - 33 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Ef

  19. Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study

    PubMed Central

    Oshika, T.; Nagata, T.; Ishii, Y.

    1998-01-01

    AIMS—To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule.
METHODS—Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically.
RESULTS—The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicone IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL.
CONCLUSIONS—The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification.

 Keywords: intraocular lens; lens capsule; posterior capsule opacification; adhesion PMID:9713064

  20. Cycloolefin effect in cycloolefin-(meth)acryl copolymer

    NASA Astrophysics Data System (ADS)

    Lim, Hyun Soon; Seo, Dong Chul; Lee, Chang Soo; Park, Sang Wok; Kim, Sang Jin; Shin, Dae Hyeon; Shin, Jin Bong; Park, Joo Hyun

    2008-11-01

    One of the most important factors in ArF resist development is a resin platform, which dominates a lot of parts of resist characteristics. It has been much changed in order to improve their physical properties such as resolution, pattern profile, etch resistance and line edge roughness. Through the low etch resistance in ArF initial (meth)acryl type copolymer and low transmittance in COMA type copolymer most researchers were interested in developing of (meth)acryl type copolymer again for ArF photoresist. On the other hand, we have studied various polymer platforms suitable ArF photoresist except for meth(acryl) type copolymer. As a result of this study we had developed ROMA type polymers and cycloolefin-(meth)acryl type copolymers. Among the polymers cycloolefin-(meth)acryl type copolymer has many attractions such as etch roughness, resist reflow which needs low glass transition temperature and solvent solubility. In this study, we intend to find out cycloolefin-(meth)acryl copolymer characteristics compared with (meth)acryl copolymer. And, we have tried to find out any differences between acrylate type copolymer and cycloolefin-(meth)acrylate type copolymer with various evaluation results. As a result of this study we are going to talk about the reason that the resist using acrylate type copolymer and cycloolefin-(meth)acryl type copolymer show good pattern profile while acrylate type copolymer show poor pattern profile. We also intend to explain the role of cycloolefin as a function of molecular weight variation and substitution ratio variation of cycloolefin in cycloolefin-(meth)acrylate resin.One of the most important factors in ArF resist development is a resin platform, which dominates a lot of parts of resist characteristics. It has been much changed in order to improve their physical properties such as resolution, pattern profile, etch resistance and line edge roughness. Through the low etch resistance in ArF initial (meth)acryl type copolymer and low

  1. Acrylate Systemic Contact Dermatitis.

    PubMed

    Sauder, Maxwell B; Pratt, Melanie D

    2015-01-01

    Acrylates, the 2012 American Contact Dermatitis Society allergen of the year, are found in a range of products including the absorbent materials within feminine hygiene pads. When fully polymerized, acrylates are nonimmunogenic; however, if not completely cured, the monomers can be potent allergens.A 28-year-old woman is presented, who had her teeth varnished with Isodan (Septodont, Saint-Maur-des-Fossés, France) containing HEMA (2-hydroxyethyl methacrylate) with no initial reaction. Approximately 1 month later, the patient developed a genital dermatitis secondary to her feminine hygiene pads. The initial reaction resolved, but 5 months later, the patient developed a systemic contact dermatitis after receiving a second varnishing.The patient was dramatically patch test positive to many acrylates. This case demonstrates a reaction to likely unpolymerized acrylates within a feminine hygiene pad, as well as broad cross-reactivity or cosensitivity to acrylates, and possibly a systemic contact dermatitis with systemic re-exposure to unpolymerized acrylates.

  2. Silicone/Acrylate Copolymers

    NASA Technical Reports Server (NTRS)

    Dennis, W. E.

    1982-01-01

    Two-step process forms silicone/acrylate copolymers. Resulting acrylate functional fluid is reacted with other ingredients to produce copolymer. Films of polymer were formed by simply pouring or spraying mixture and allowing solvent to evaporate. Films showed good weatherability. Durable, clear polymer films protect photovoltaic cells.

  3. Postoperative occlusion of visual axis with fibrous membrane in the presence of anterior capsular phimosis in a patient with pseudoexfoliation syndrome: a case report.

    PubMed

    Kim, Eung Suk; Kim, Moosang; Lee, Seung-Jun; Han, Sang Beom; Yang, Hee Kyung; Hyon, Joon Young

    2016-12-07

    To report a case of postoperative fibrous membrane formation occluding the visual axis in the presence of anterior capsular phimosis in a patient with pseudoexfoliation syndrome. A 79-year-old Asian woman with pseudoexfoliation syndrome underwent uneventful phacoemulsification and implantation of one-piece hydrophilic acrylic square-edged intraocular lens (Cristalens) in the right eye. Two months later, she had blurred vision in the right eye with the best-corrected visual acuity (BCVA) of 20/40. Formation of fibrous membrane occluding the capsulorhexis opening with contraction of anterior capsule was observed, which was confirmed by anterior segment optical coherence tomography. Clear visual axis was achieved by lysis of the membrane using Nd:YAG laser. The BCVA improved to 20/20. Occlusion of the visual axis with fibrous membrane can develop in the presence of anterior capsular phimosis in a patient with pseudoexfoliation syndrome.

  4. Acrylic vessel cleaning tests

    SciTech Connect

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-02-26

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory.

  5. Acrylic mechanical bond tests

    SciTech Connect

    Wouters, J.M.; Doe, P.J.

    1991-02-01

    The tensile strength of bonded acrylic is tested as a function of bond joint thickness. 0.125 in. thick bond joints were found to posses the maximum strength while the acceptable range of joints varied from 0.063 in. to almost 0.25 in. Such joints are used in the Sudbury Neutrino Observatory.

  6. Acrylic cranioplasty using miniplate struts.

    PubMed

    Replogle, R E; Lanzino, G; Francel, P; Henson, S; Lin, K; Jane, J A

    1996-10-01

    Cranioplasty using acrylic is a common procedure in patients with cranial defects secondary to trauma, infection, or tumor. The limitations of this technique include poor adherence of the acrylic to surrounding bone and difficulty in achieving a proper cosmetic contour in complicated cranial defects, especially those involving the orbital rim. The authors have been continually developing techniques of cranioplasty. Ten consecutive cranioplasties were performed over the past 5 years using this new technique. The authors describe a technique using miniplates as struts to which the acrylic is applied using a "reinforced concrete" principle. All patients achieved excellent cosmetic results with no complications. This technique allows contour of the repair site while the acrylic is curing and provides a more resilient resulting prosthesis.

  7. Pilot study of a new acrylic cage in a dog cervical spine fusion model.

    PubMed

    Farrokhi, Majid Reza; Torabinezhad, Simin; Ghajar, Korush Azodi

    2010-06-01

    An experimental pilot study using an acrylic interbody cage in a dog cervical spine fusion model. To compare bony fusion in autologous bone grafting with a novel acrylic cage in terms of preservation of disc height, biomechanical properties, and histologic characteristics. Degenerative diseases of cervical intervertebral discs are commonly treated by anterior decompression and interbody fusion. To restore physiologic disc height and achieve fusion, the disc is replaced with bone graft, bone cement, interbody fusion cages, or other materials. The advantages of bone cement in contrast to bone graft and interbody fusion cages are immediate stability and less subsidence, although real bony fusion cannot be achieved. To overcome this problem, we designed a new, inexpensive acrylic cage. Ten adult hybrid dogs underwent C3/C4 (5 dogs) and C4/C5 (5 dogs) discectomy and fusion with an acrylic interbody fusion cage made of polymethylmethacrylate filled with bone graft (n=5, group1) or an autologous iliac bone graft (n=5, group 2). Dynamic functional x-ray was obtained 1 and 12 weeks after the operation. After 12 weeks, the animals were killed and fusion sites were evaluated with quantitative computed tomographic scanning to evaluate bone mineral density. Subsistence was quantified with biomechanical testing. Histopathologic analysis was used to evaluate fusion and possible foreign body reactions associated with the acrylic cage. The acrylic cage led to significantly higher disc space height and less subsidence than bone grafting (P<0.021). Bone mineral density after 12 weeks was greater with the acrylic cage, but the difference was not statistically significant. Histologically, new bony tissue and hyaline cartilage were seen inside the acrylic cage, accompanied by mild chronic inflammation. The acrylic cage showed significantly higher mechanical stiffness and less subsidence than bone grafting. Additional studies with more subjects and longer follow-up periods are needed to

  8. Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

    PubMed Central

    2016-01-01

    PURPOSE This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05). RESULTS The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth. PMID:27555897

  9. Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution.

    PubMed

    Thongrakard, Ticha; Wiwatwarrapan, Chairat

    2016-08-01

    This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05). The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

  10. Comparative analysis of skin sensitization potency of acrylates (methyl acrylate, ethyl acrylate, butyl acrylate, and ethylhexyl acrylate) using the local lymph node assay.

    PubMed

    Dearman, Rebecca J; Betts, Catherine J; Farr, Craig; McLaughlin, James; Berdasco, Nancy; Wiench, Karin; Kimber, Ian

    2007-10-01

    There are currently available no systematic experimental data on the skin sensitizing properties of acrylates that are of relevance in occupational settings. Limited information from previous guinea-pig tests or from the local lymph node assay (LLNA) is available; however, these data are incomplete and somewhat contradictory. For those reasons, we have examined in the LLNA 4 acrylates: butyl acrylate (BA), ethyl acrylate (EA), methyl acrylate (MA), and ethylhexyl acrylate (EHA). The LLNA data indicated that all 4 compounds have some potential to cause skin sensitization. In addition, the relative potencies of these acrylates were measured by derivation from LLNA dose-response analyses of EC3 values (the effective concentration of chemical required to induce a threefold increase in proliferation of draining lymph node cells compared with control values). On the basis of 1 scheme for the categorization of skin sensitization potency, BA, EA, and MA were each classified as weak sensitizers. Using the same scheme, EHA was considered a moderate sensitizer. However, it must be emphasized that the EC3 value for this chemical of 9.7% is on the borderline between moderate (<10%) and weak (>10%) categories. Thus, the judicious view is that all 4 chemicals possess relatively weak skin sensitizing potential.

  11. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under this...

  12. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under this...

  13. 63 FR 41279 - Acrylic Sheet From Japan

    Federal Register 2010, 2011, 2012, 2013, 2014

    1998-08-03

    ... COMMISSION Acrylic Sheet From Japan AGENCY: United States International Trade Commission. ACTION: Institution of a five-year review concerning the antidumping duty order on acrylic sheet from Japan. SUMMARY: The... order on acrylic sheet from Japan would be likely to lead to continuation or recurrence of...

  14. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under...

  15. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate ester. 721.2805 Section 721... Acrylate ester. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an acrylate ester (PMN P-96-824) is subject to reporting under...

  16. Mixing It Up with Acrylics.

    ERIC Educational Resources Information Center

    Laird, Shirley

    1999-01-01

    Presents an art activity for fifth-grade students in which they learn about basic shapes and what happens when shapes overlap, draw seven overlapping geometric shapes, review the use of acrylic paint and mixing colors, and finally paint with primary colors. (CMK)

  17. Mixing It Up with Acrylics.

    ERIC Educational Resources Information Center

    Laird, Shirley

    1999-01-01

    Presents an art activity for fifth-grade students in which they learn about basic shapes and what happens when shapes overlap, draw seven overlapping geometric shapes, review the use of acrylic paint and mixing colors, and finally paint with primary colors. (CMK)

  18. Two decades of occupational (meth)acrylate patch test results and focus on isobornyl acrylate.

    PubMed

    Christoffers, Wietske A; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise A

    2013-08-01

    Acrylates constitute an important cause of occupational contact dermatitis. Isobornyl acrylate sensitization has been reported in only 2 cases. We encountered an industrial process operator with occupational contact dermatitis caused by isobornyl acrylate. (i) To investigate whether it is relevant to add isobornyl acrylate to the (meth)acrylate test series. (ii) To report patients with (meth)acrylate contact allergy at an occupational dermatology clinic. Our patch test database was screened for positive reactions to (meth)acrylates between 1993 and 2012. A selected group of 14 patients was tested with an isobornyl acrylate dilution series: 0.3%, 0.1%, 0.033%, and 0.01%. Readings were performed on D2, D3, and D7. One hundred and fifty-one patients were tested with our (meth)acrylate series; 24 had positive reactions. Most positive reactions were to 2-hydroxypropyl acrylate, 2-hydroxyethyl acrylate, 2-hydroxypropyl methacrylate, and diethyleneglycol diacrylate. Hypothetical screening with 2-hydroxypropyl acrylate, ethyleneglycol dimethacrylate, ethoxylated bisphenol A glycol dimethacrylate and trimethylolpropane triacrylate identified 91.7% of the 24 patients. No positive reactions were observed in 14 acrylate-positive patients tested with the isobornyl acrylate dilution series. The 0.3% isobornyl acrylate concentration induced irritant reactions in 3 patients. We report a rare case of allergic contact dermatitis caused by isobornyl acrylate. However, this study provides insufficient support for isobornyl acrylate to be added to a (meth)acrylate series. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Posterior capsule opacification in rabbit eyes implanted with 1-piece and 3-piece hydrophobic acrylic intraocular lenses.

    PubMed

    Werner, Liliana; Mamalis, Nick; Izak, Andrea M; Pandey, Suresh K; Davis, Brandon L; Nilson, Chistian D; Weight, Christopher; Apple, David J

    2005-04-01

    To evaluate the outcome of posterior capsule opacification (PCO) after implantation in rabbit eyes of currently available 3-piece and 1-piece hydrophobic acrylic intraocular lenses (IOLs) with square optic edges. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. The 3-piece designs evaluated were the AR40e (Advanced Medical Optics Inc.) and the MA60AC (Alcon, Inc.); the 1-piece designs were the SA60AT and the SA30AT (Alcon, Inc.). Nine lenses of each type were implanted in a randomized manner by the same surgeon in 18 Dutch Belted pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and analyses of the enucleated eyes were performed from the posterior or Miyake-Apple view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was scored from 0 to 4. The area of Soemmering's ring formation was also scored from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL anterior surface, IOL centration, fixation, and presence of striae. Results from the posterior view were complemented by histopathologic evaluation of the eyes. No statistically significant difference was found between the 4 groups of IOLs in the parameters analyzed from the posterior view. When cell ingrowth occurred with the 1-piece designs, causing peripheral and central PCO formation, it was more likely to start at the optic-haptic junctions, as observed during the clinical follow-up with slitlamp examination and confirmed by gross and histopathologic analyses of the enucleated eyes. The square, truncated optic edge is the most important IOL design feature for PCO prevention. The optic-haptic junctions of the 1-piece designs appear to be sites where the barrier effect of the truncated optic edge is less effective.

  20. A method for preparing sodium acrylate-d3, a useful and stable precursor for deuterated acrylic monomers

    SciTech Connect

    Yang, Jun; Hong, Kunlun; Bonnesen, Peter V

    2011-01-01

    A convenient and economical method for converting propiolic acid to sodium acrylate-d3 is described. Successive D/H exchange of the alkyne proton of sodium propiolate (prepared from propiolic acid) using D2O affords sodium propiolate-d having up to 99 atom% D. Sodium propiolate-d can be partially reduced to sodium acrylate-d3 with 90% conversion and 89% yield, using D2 and the Lindlar catalyst with control of reaction parameters to maximize conversion while minimizing over reduction.

  1. (Meth)Acrylate Vinyl Ester Hybrid Polymerizations

    PubMed Central

    Lee, TaiYeon; Cramer, Neil; Hoyle, Charles; Stansbury, Jeffrey

    2009-01-01

    In this study vinyl ester monomers were synthesized by an amine catalyzed Michael addition reaction between a multifunctional thiol and the acrylate double bond of vinyl acrylate. The copolymerization behavior of both methacrylate/vinyl ester and acrylate/vinyl ester systems was studied with near-infrared spectroscopy. In acrylate/vinyl ester systems, the acrylate groups polymerize faster than the vinyl ester groups resulting in an overall conversion of 80% for acrylate double bonds in the acrylate/vinyl ester system relative to only 50% in the bulk acrylate system. In the methacrylate/vinyl ester systems, the difference in reactivity is even more pronounced resulting in two distinguishable polymerization regimes, one dominated by methacrylate polymerization and a second dominated by vinyl ester polymerization. A faster polymerization rate and higher overall conversion of the methacrylate double bonds is thus achieved relative to polymerization of the pure methacrylate system. The methacrylate conversion in the methacrylate/vinyl ester system is near 100% compared to only ~60% in the pure methacrylate system. Utilizing hydrophilic vinyl ester and hydrophobic methacrylate monomers, polymerization-induced phase separation is observed. The phase separated domain size is on the order of ~1 μm under the polymerization conditions. The phase separated domains become larger and more distinct with slower polymerization and correspondingly increased time for diffusion. PMID:19855853

  2. Edge Bioinformatics

    SciTech Connect

    Lo, Chien-Chi

    2015-08-03

    Edge Bioinformatics is a developmental bioinformatics and data management platform which seeks to supply laboratories with bioinformatics pipelines for analyzing data associated with common samples case goals. Edge Bioinformatics enables sequencing as a solution and forward-deployed situations where human-resources, space, bandwidth, and time are limited. The Edge bioinformatics pipeline was designed based on following USE CASES and specific to illumina sequencing reads. 1. Assay performance adjudication (PCR): Analysis of an existing PCR assay in a genomic context, and automated design of a new assay to resolve conflicting results; 2. Clinical presentation with extreme symptoms: Characterization of a known pathogen or co-infection with a. Novel emerging disease outbreak or b. Environmental surveillance

  3. Radiopurity measurement of acrylic for DEAP-3600

    SciTech Connect

    Nantais, C. M.; Boulay, M. G.; Cleveland, B. T.

    2013-08-08

    The spherical acrylic vessel that contains the liquid argon target is the most critical detector component in the DEAP-3600 dark matter experiment. Alpha decays near the inner surface of the acrylic vessel are one of the main sources of background in the detector. A fraction of the alpha energy, or the recoiling nucleus from the alpha decay, could misreconstruct in the fiducial volume and result in a false candidate dark matter event. Acrylic has low levels of inherent contamination from {sup 238}U and {sup 232}Th. Another background of particular concern is diffusion of {sup 222}Rn during manufacturing, leading to {sup 210}Pb contamination. The maximum acceptable concentrations in the DEAP-3600 acrylic vessel are ppt levels of {sup 238}U and {sup 232}Th equivalent, and 10{sup −8} ppt {sup 210}Pb. The impurities in the bulk acrylic will be measured by vaporizing a large quantity of acrylic and counting the concentrated residue with ultra-low background HPGe detectors and a low background alpha spectrometer. An overview of the acrylic assay technique is presented.

  4. The skewer technique for anterior capsule remnants.

    PubMed

    Hecht, S D; McCarthy, E F

    1984-07-01

    A technique has been developed which enables the removal of a narrow, long remnant of anterior capsule which is connected inferiorly and inadvertently left during planned extracapsular cataract surgery. The technique is especially useful when the wound has already been partly or completely closed. A partial thickness incision is made at the limbus and a short 30-gauge needle is inserted through the incision into the anterior chamber. The needle then skewers the remnant, tearing it along its edge. The end of the capsular remnant is put on stretch by grasping its edge with a small forceps. This results in a transverse tear, with amputation of the remnant.

  5. Monolithic F-16 Uniform Thickness Stretched Acrylic Canopy Transparency Program

    DTIC Science & Technology

    1984-01-01

    Thermoforming Finite Strain Analysis Finite Element Modeling Mooney Formulation Tensile Testing Acrylic Material Properties F-16 Transparency Thinning Uniform...OF ACRYLIC TENSILE SPECIMEN ...... 8 MARC ANALYSIS OF ACRYLIC HEMISPHERE ............ 12 IV ACRYLIC MATERIAL PROPERTIES AT THERMOFORMING TEMPERATURES...properties (necessary for finite element stress analysis work) were generated at temperatures in the range of thermoforming . A finite element code

  6. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the greater...

  7. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the greater...

  8. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the greater...

  9. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... acrylamide with partial hydrolysis, or by copolymerization of acrylamide and acrylic acid with the greater...

  10. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid... for use in contact with food subject to the provisions of this section. (a) The ethylene-acrylic acid...

  11. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be...) Acrylamide-acrylic acid resins are produced by the polymerization of acrylamide with partial hydrolysis or by...

  12. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic...) Identity. For the purpose of this section, n-alkylglutarimide/acrylic copolymers are copolymers obtained by...

  13. Poly(meth)acrylate-based coatings.

    PubMed

    Nollenberger, Kathrin; Albers, Jessica

    2013-12-05

    Poly(meth)acrylate coatings for pharmaceutical applications were introduced in 1955 with the launch of EUDRAGIT(®) L and EUDRAGIT(®) S, two types of anionic polymers. Since then, by introducing various monomers into their polymer chains and thus altering their properties, diverse forms with specific characteristics have become available. Today, poly(meth)acrylates function in different parts of the gastrointestinal tract and/or release the drug in a time-controlled manner. This article reviews the properties of various poly(meth)acrylates and discusses formulation issues as well as application possibilities.

  14. New radiopaque acrylic bone cement. II. Acrylic bone cement with bromine-containing monomer.

    PubMed

    Rusu, M C; Ichim, I C; Popa, M; Rusu, M

    2008-07-01

    Bromine-containing methacrylate, 2-(2-bromopropionyloxy) ethyl methacrylate (BPEM), had been used in the formulation of acrylic radiopaque cements. The effect of this monomer incorporated into the liquid phase of acrylic bone cement, on the curing parameters, thermal properties, water absorption, density, compression tests and radiopacity was studied. A decrease of maximum temperature and an increase of the setting time were observed with the addition of the bromine-containing monomer in the radiolucent cement composition. Adding BPEM in radiolucent acrylic bone cements composition results in the decrease of glass transition temperature and increase of its thermal stability. Acrylic bone cements modified with bromine-containing comonomer are characterized by polymerization shrinkage lower than the radiolucent cement. Addition of bromine-containing comonomer in radiolucent acrylic bone cement composition determines the increase of compressive strength. Acrylic bone cements modified with bromine-containing comonomer proved to be radiopaque.

  15. A Study on Effect of Surface Treatments on the Shear Bond Strength between Composite Resin and Acrylic Resin Denture Teeth.

    PubMed

    Chatterjee, Nirmalya; Gupta, Tapas K; Banerjee, Ardhendu

    2011-03-01

    Visible light-cured composite resins have become popular in prosthetic dentistry for the replacement of fractured/debonded denture teeth, making composite denture teeth on partial denture metal frameworks, esthetic modification of denture teeth to harmonize with the characteristics of adjacent natural teeth, remodelling of worn occlusal surfaces of posterior denture teeth etc. However, the researches published on the bond strength between VLC composite resins and acrylic resin denture teeth is very limited. The purpose of this study is to investigate the effect of five different methods of surface treatments on acrylic resin teeth on the shear bond strength between light activated composite resin and acrylic resin denture teeth. Ninety cylindrical sticks of acrylic resin with denture teeth mounted atop were prepared. Various treatments were done upon the acrylic resin teeth surfaces. The samples were divided into six groups, containing 15 samples each. Over all the treated and untreated surfaces of all groups, light-cured composite resin was applied. The shear strengths were measured in a Universal Testing Machine using a knife-edge shear test. Data were analyzed using one way analysis of variance (ANOVA) and mean values were compared by the F test. Application of bonding agent with prior treatment of methyl methacrylate on the acrylic resin denture teeth resulted in maximum bond strength with composite resin.

  16. EVALUATION OF AN ACRYLATE TERPOLYMER, POLYURETHANE COMPOSITE.

    DTIC Science & Technology

    Composite films consisting of a flexible acrylate terpolymer substrate and an outer layer of poly (ester-urethane) elastomer were prepared and evaluated for use in cosmetic glove applications. (Author)

  17. Mechanistic insights on acrylate insertion polymerization.

    PubMed

    Guironnet, Damien; Caporaso, Lucia; Neuwald, Boris; Göttker-Schnetmann, Inigo; Cavallo, Luigi; Mecking, Stefan

    2010-03-31

    Complexes [{(PwedgeO)PdMe}(n)] (1(n); PwedgeO = kappa(2)-P,O-Ar(2)PC(6)H(4)SO(2)O with Ar = 2-MeOC(6)H(4)) are a single-component precursor of the (PwedgeO)PdMe fragment devoid of additional coordinating ligands, which also promotes the catalytic oligomerization of acrylates. Exposure of 1(n) to methyl acrylate afforded the two diastereomeric chelate complexes [(PwedgeO)Pd{kappa(2)-C,O-CH(C(O)OMe)CH(2)CH(C(O)OMe)CH(2)CH(3)}] (3-meso and 3-rac) resulting from two consecutive 2,1-insertions of methyl acrylate into the Pd-Me bond with the same or opposite stereochemistry, respectively, in a 3:2 ratio as demonstrated by comprehensive NMR spectroscopic studies and single crystal X-ray diffraction. These six-membered chelate complexes are direct key models for intermediates of acrylate insertion polymerization, and also ethylene-acrylate copolymerization to high acrylate content copolymers. Studies of the binding of various substrates (pyridine, dmso, ethylene and methyl acrylate) to 3-meso and 3-rac show that hindered displacement of the chelating carbonyl moiety by pi-coordination of incoming monomer significantly retards, but does not prohibit, polymerization. For 3-meso,3-rac + C(2)H(4) right arrow over left arrow 3-meso-C(2)H(4,) 3-rac-C(2)H(4) an equilibrium constant K(353 K) approximately 2 x 10(-3) L mol(-1) was estimated. Reaction of 3-meso, 3-rac with methyl acrylate afforded higher insertion products [(PwedgeO)Pd(C(4)H(6)O(2))(n)Me] (n = 3, 4) as observed by electrospray ionization mass spectrometry (ESI-MS). Theoretical studies by DFT methods of consecutive acrylate insertion provide relative energies of intermediates and transition states, which are consistent with the aforementioned experimental observations, and give detailed insights to the pathways of multiple consecutive acrylate insertions. Acrylate insertion into 3-meso,3-rac is associated with an overall energy barrier of ca. 100 kJ mol(-1).

  18. Chemical Stress Cracking of Acrylic Fibers.

    DTIC Science & Technology

    1982-05-01

    nitrile groups (similar to the "prefatory reaction" in pyrolysis of acrylic fibers), followed immediately by N- chlorination and7 chain scission...cyclization of nitrile groups (similar to the "prefatory reaction" in pyrolysis of acrylic fibers), followed immediately by N- chlorination and chain scission...present experiments were conducted at the boil, slightly greater than 100 C. The decomposition products-- chlorine , chlorate, plus oxygen originating

  19. Determination of selected fate and aquatic toxicity characteristics of acrylic acid and a series of acrylic esters.

    PubMed

    Staples, C A; Murphy, S R; McLaughlin, J E; Leung, H W; Cascieri, T C; Farr, C H

    2000-01-01

    Acrylic acid, methyl acrylate, ethyl acrylate, and butyl acrylate are commercially important and widely used materials. This paper reports the results of a series of fate and aquatic toxicity studies. The mobility in soil of acrylic acid and its esters ranged from 'medium' to 'very high'. Calculated bioconcentration factors ranged from 1 to 37, suggesting a low bioconcentration potential. Acrylic acid and methyl acrylate showed limited biodegradability in the five day biochemical oxygen demand (BOD5) test, while ethyl acrylate and butyl acrylate were degraded easily (77% and 56%, respectively). Using the OECD method 301D 28-d closed bottle test, degradability for acrylic acid was 81% at 28 days, while the acrylic esters ranged from 57% to 60%. Acrylic acid degraded rapidly to carbon dioxide in soil (t1/2 < 1 day). Toxicity tests were conducted using freshwater and marine fish, invertebrates, and algae. Acrylic acid effect concentrations for fish and invertebrates ranged from 27 to 236 mg/l. Effect concentrations (LC50 or EC50) for fish and invertebrates using methyl acrylate, ethyl acrylate, and butyl acrylate ranged from 1.1 to 8.2 mg/l. The chronic MATC for acrylic acid with Daphnia magna was 27 mg/l based on length and young produced per adult reproduction day and for ethyl acrylate was 0.29 mg/l based on both the reproductive and growth endpoints. Overall these studies show that acrylic acid and the acrylic esters studied can rapidly biodegrade, have a low potential for persistence or bioaccumulation in the environment, and have low to moderate toxicity.

  20. Biologic Restoration: A Treatment Option for Reconstruction of Anterior Teeth

    PubMed Central

    Khanna, Priyanka; S, Shankar; Chaurasia, Vishwajit Rampratap; Masamatti, Vinaykumar S

    2014-01-01

    Several procedures are advised to manage fractured anterior tooth structure using acrylic resin, composite restoration, ceramic or metal crown with ceramic facing. Biologic restoration is a procedure to restore fractured tooth structure with natural tooth material. In this in vitro case we have made an attempt for aesthetic rehabilitation of maxillary central incisor with similar biologic crown taken form extracted maxillary central incisor. It was observed that biologic restoration is an aesthetic, economical, fast and functional procedure which can be used as an alternative method to restore fractured primary or permanent anteriors. PMID:25584332

  1. Biologic restoration: a treatment option for reconstruction of anterior teeth.

    PubMed

    Babaji, Prashant; Khanna, Priyanka; S, Shankar; Chaurasia, Vishwajit Rampratap; Masamatti, Vinaykumar S

    2014-11-01

    Several procedures are advised to manage fractured anterior tooth structure using acrylic resin, composite restoration, ceramic or metal crown with ceramic facing. Biologic restoration is a procedure to restore fractured tooth structure with natural tooth material. In this in vitro case we have made an attempt for aesthetic rehabilitation of maxillary central incisor with similar biologic crown taken form extracted maxillary central incisor. It was observed that biologic restoration is an aesthetic, economical, fast and functional procedure which can be used as an alternative method to restore fractured primary or permanent anteriors.

  2. Edge Detection,

    DTIC Science & Technology

    1985-09-01

    PROJECT. T ASK0 Artificial Inteligence Laboratory AREA It WORK UNIT NUMBERS V 545 Technology Square ( Cambridge, HA 02139 I I* CONTOOL1LIN@4OFFICE NAME...ARD-A1t62 62 EDGE DETECTION(U) NASSACNUSETTS INST OF TECH CAMBRIDGE 1/1 ARTIFICIAL INTELLIGENCE LAB E C HILDRETH SEP 85 AI-M-8 N99SI4-8S-C-6595...used to carry out this analysis. cce~iO a N) ’.~" D LI’BL. P p ------------ Sj. t i MASSACHUSETTS INSTITUTE OF TECHNOLOGY i ARTIFICIAL INTELLIGENCE

  3. Bond Strength of Repaired Acrylic Denture Teeth Using Visible Light Cure Composite Resin

    PubMed Central

    Muhsin, Saja Ali

    2017-01-01

    Background: Although bonding to denture teeth after surface treatment with chemical agents is desirable, there is little information on the use of Visible Light Cure composite resin (VLC) as bonding denture materials. Objectives: To determine the effect of various surface treatments on shear bond strength between Visible Light Cure composite resin and the acrylic denture teeth interface. Methods: Forty cylindrical sticks of acrylic resin with denture teeth mounted atop were prepared. Various treatments were implemented upon the acrylic resin teeth surfaces. The samples were divided into four groups (n = 10). Light-cured composite resin (LC) was applied over all treated and untreated surfaces of tested groups. The shear bond was tested using a universal tensile testing apparatus with the knife-edge of a 0.8mm shear tester. Data were statistically analyzed using one-way ANOVA performed at a confidence level of 95% and significant P-value of (P ≤ 0.05). Results: Analysis of variance (ANOVA) showed statistically significant difference (P < 0.05) between treated and untreated teeth surfaces. The treated surfaces exhibited various levels of bond strength depending on the type of treatment. Conclusion: Application of VLC bonding agent with prior treatment of methylmethacrylate (MMA) on the acrylic resin denture teeth resulted in maximum bond strength with composite resin. PMID:28400865

  4. Bond Strength of Repaired Acrylic Denture Teeth Using Visible Light Cure Composite Resin.

    PubMed

    Muhsin, Saja Ali

    2017-01-01

    Although bonding to denture teeth after surface treatment with chemical agents is desirable, there is little information on the use of Visible Light Cure composite resin (VLC) as bonding denture materials. To determine the effect of various surface treatments on shear bond strength between Visible Light Cure composite resin and the acrylic denture teeth interface. Forty cylindrical sticks of acrylic resin with denture teeth mounted atop were prepared. Various treatments were implemented upon the acrylic resin teeth surfaces. The samples were divided into four groups (n = 10). Light-cured composite resin (LC) was applied over all treated and untreated surfaces of tested groups. The shear bond was tested using a universal tensile testing apparatus with the knife-edge of a 0.8mm shear tester. Data were statistically analyzed using one-way ANOVA performed at a confidence level of 95% and significant P-value of (P ≤ 0.05). Analysis of variance (ANOVA) showed statistically significant difference (P < 0.05) between treated and untreated teeth surfaces. The treated surfaces exhibited various levels of bond strength depending on the type of treatment. Application of VLC bonding agent with prior treatment of methylmethacrylate (MMA) on the acrylic resin denture teeth resulted in maximum bond strength with composite resin.

  5. Allergic contact dermatitis to acrylates in disposable blue diathermy pads.

    PubMed Central

    Sidhu, S. K.; Shaw, S.

    1999-01-01

    We report 2 cases of elicitation of allergic contact dermatitis to acrylates from disposable blue diathermy pads used on patients who underwent routine surgery. Their reactions were severe, and took approximately 5 weeks to resolve. Both patients gave a prior history of finger tip dermatitis following the use of artificial sculptured acrylic nails, which is a common, but poorly reported, cause of acrylate allergy. Patch testing subsequently confirmed allergies to multiple acrylates present in both the conducting gel of disposable blue diathermy pads, and artificial sculptured acrylic nails. We advocate careful history taking prior to surgery to avoid unnecessary exposure to acrylates in patients already sensitized. Images Figure 1 Figure 2 PMID:10364952

  6. Comparative evaluation of shear compressive bond strength between cross-linked acrylic resin denture base and cross-linked acrylic resin teeth with different modifcations of their ridge lap surfaces.

    PubMed

    Sadar, Leena; Dhume, Swaroop; Maniar, Neena; Prakash Patil, Jeevan; Rane, Prasad; Gandhewar, Mahesh

    2013-09-01

    A major problem commonly observed in denture wearer is the detachment of artifcial tooth/teeth from acrylic denture base. The problem was grave when porcelain teeth used along with the then available denture base materials. The bond formed was purely mechanical and hence debonding of teeth from denture base was a frequent occurrence. Inspite of chemical union between acrylic resin teeth and acrylic denture base material, detachment of teeth particularly anterior teeth is a frequent observation. The objective of the study is to study the effect of change in the surface treatment and surface confguration of ridge lap surface of the teeth on retention of cross-linked acrylic teeth on cross-linked acrylic resin denture base. Sixty specimens were tested for the shear compressive bond strength using instron universal testing machine in KN. Statistical analysis is used. The fndings were analyzed using one-way analysis of variance (ANOVA) and 't' test. Slight modifcation in the ridge lap surface of artifcial teeth alters the strength of the shear compressive bond. Sand papering of ridge lap surfaces improves the shear compressive bond then the one without any modifcation. Maximum shear compressive bond strength can be increased by application of monomer.

  7. Empty-bag technique for acrylic intraocular lens implantation using Healon5.

    PubMed

    Cionni, Robert J; Temel, Mustafa; Marques, Daniela M V; Marques, Frederico F

    2004-02-01

    To determine how often the empty-bag technique (EBT) for injecting an acrylic foldable intraocular lens (IOL) into the capsular bag using Healon5 (sodium hyaluronate 2.3%) will require a 2-compartment technique to remove the ophthalmic viscosurgical device (OVD) and compare this with that of a standard injection method using Healon5. Cincinnati Eye Institute and Ambulatory Surgical Center, Cincinnati, Ohio, USA. Forty-one eyes of 40 patients were randomly assigned to 1 of 2 groups. In Group A, standard capsular bag expansion was performed with Healon5 before implantation of an acrylic posterior chamber (PC) IOL. In Group B, Healon5 was placed in the anterior chamber followed by balanced salt solution expansion of the capsular bag before acrylic PC IOL implantation. In all patients, complete OVD removal was attempted with the automated aspiration tip anterior to the optic (rock 'n roll technique). The number of patients in each group who required placement of the aspiration tip posterior to the optic for complete removal was compared. Early postoperative intraocular pressure (IOP) was also compared. In Group A, 15 (75%) of 20 eyes required placement of the aspiration tip posterior to the optic for complete OVD removal and in Group B, 1 (0.05%) of 20 eyes. The postoperative IOP was similar in both groups. The EBT decreased the likelihood that a 2-compartment OVD removal method would be necessary when using Healon5 for acrylic PC IOL implantation. The limitations of this new technique must be fully understood before it is used.

  8. Frenectomy with anterior lingual sulcoplasty for an implant-supported overdenture: A clinical report.

    PubMed

    Perri de Carvalho, Paulo Sergio; Janjacomo, Luiz Antonio; Ponzoni, Daniela

    2016-04-01

    This clinical report describes the deepening of a patient's anterior mandibular lingual sulcus in combination with frenectomy and the use of an acrylic resin guiding device fixed to an osseointegrated dental implant to maintain the patency of the new sulcular depth.

  9. Calcification of a hydrophilic acrylic intraocular lens after Descemet-stripping endothelial keratoplasty: case report and laboratory analyses.

    PubMed

    Fellman, Melissa A; Werner, Liliana; Liu, Erica T; Stallings, Shannon; Floyd, Anne M; van der Meulen, Ivanka J E; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P

    2013-05-01

    We describe the case of an 83-year-old woman who had uneventful phacoemulsification with implantation of a tripod hydrophilic acrylic intraocular lens (IOL). Because of postoperative corneal decompensation, 2 Descemet-stripping endothelial keratoplasty (DSEK) procedures were performed within 2 years. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. Approximately 9 months later, opacification was observed on the anterior surface of the IOL, with a significant decrease in visual acuity. The IOL was explanted within the capsular bag. Laboratory analyses revealed granular deposits densely distributed in a round pattern within the margins of the capsulorhexis. Granules were located at the anterior surface/subsurface of the IOL and stained positive for calcium (alizarin red and von Kossa method). Scheimpflug photography revealed high levels of light scattering from the opacified area. Surgeons should be aware of possible localized calcification following DSEK procedures in pseudophakic patients with hydrophilic acrylic IOLs.

  10. Two-year follow-up of posterior capsule opacification after implantation of a hydrophilic or hydrophobic acrylic intraocular lens.

    PubMed

    Kugelberg, Maria; Wejde, Gisela; Jayaram, Hari; Zetterström, Charlotta

    2008-08-01

    To evaluate posterior capsule opacification (PCO) 2 years after cataract surgery following implantation of a hydrophilic or a hydrophobic single-piece acrylic intraocular lens (IOL) with a sharp edge. Phacoemulsification cataract surgery was performed in one eye of 120 patients with senile cataract in this prospective study. They were randomized to implantation of either a hydrophilic acrylic IOL (BL27; Bausch & Lomb, Rochester, NY, USA) or a hydrophobic acrylic IOL (AcrySof) SA60AT; Alcon Laboratories, Fort Worth, TX, USA). Two years after surgery, retroillumination images were obtained and PCO area and severity were evaluated using pocoman software. Best corrected visual acuity (VA) (both high-contrast [100%] and low-contrast [2.5%]), glare, laser flare and intraocular pressure were measured. Capsulotomy rates were recorded. Patients implanted with the hydrophilic IOL had a greater percentage area and severity of PCO compared with patients with the hydrophobic IOL (p < 0.001). There was no difference in PCO between men and women in the hydrophilic group. However, in the hydrophobic group, women had significantly more PCO than men (p < 0.05). Patients with the hydrophobic acrylic IOL had better high- and low-contrast visual activity (VA) (p < 0.01) and less glare (p < 0.001) than those with a hydrophilic acrylic IOL. Of the patients with the hydrophilic IOL, 42% underwent capsulotomy, compared with 10% in the hydrophobic group (p < 0.001). Two years after surgery, patients with the SA60AT hydrophobic acrylic IOL had less PCO and better high- and low-contrast VA than patients with the BL27 hydrophilic acrylic IOL.

  11. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new uses...

  12. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Halogenated benzyl ester acrylate... Specific Chemical Substances § 721.329 Halogenated benzyl ester acrylate (generic). (a) Chemical substance... halogenated benzyl ester acrylate (PMN P-90-1527) is subject to reporting under this section for the...

  13. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS FOOD ADDITIVES PERMITTED IN FEED AND DRINKING WATER OF ANIMALS Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573...

  14. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be safely...

  15. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be safely...

  16. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be safely...

  17. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Acrylamide-acrylic acid resins. 176.110 Section 176... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in producing...

  18. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in producing...

  19. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in producing...

  20. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Halogenated benzyl ester acrylate... Specific Chemical Substances § 721.329 Halogenated benzyl ester acrylate (generic). (a) Chemical substance... halogenated benzyl ester acrylate (PMN P-90-1527) is subject to reporting under this section for the...

  1. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new uses...

  2. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  3. 40 CFR 721.484 - Fluorinated acrylic copolymer (generic name).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Fluorinated acrylic copolymer (generic... Specific Chemical Substances § 721.484 Fluorinated acrylic copolymer (generic name). (a) Chemical substance... fluorinated acrylic copolymer (PMN P-95-1208) is subject to reporting under this section for the...

  4. 40 CFR 721.10519 - Perfluoroalkyl acrylate copolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Perfluoroalkyl acrylate copolymer... Specific Chemical Substances § 721.10519 Perfluoroalkyl acrylate copolymer (generic). (a) Chemical... as perfluoroalkyl acrylate copolymer (PMN P-11-63) is subject to reporting under this section for the...

  5. 40 CFR 721.10519 - Perfluoroalkyl acrylate copolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Perfluoroalkyl acrylate copolymer... Specific Chemical Substances § 721.10519 Perfluoroalkyl acrylate copolymer (generic). (a) Chemical... as perfluoroalkyl acrylate copolymer (PMN P-11-63) is subject to reporting under this section for the...

  6. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting under...

  7. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  8. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate...

  9. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as articles...

  10. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as articles...

  11. 21 CFR 176.110 - Acrylamide-acrylic acid resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Acrylamide-acrylic acid resins. 176.110 Section... Substances for Use Only as Components of Paper and Paperboard § 176.110 Acrylamide-acrylic acid resins. Acrylamide-acrylic acid resins may be safely used as components of articles intended for use in...

  12. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Halogenated benzyl ester acrylate... Specific Chemical Substances § 721.329 Halogenated benzyl ester acrylate (generic). (a) Chemical substance... halogenated benzyl ester acrylate (PMN P-90-1527) is subject to reporting under this section for...

  13. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  14. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Halogenated benzyl ester acrylate... Specific Chemical Substances § 721.329 Halogenated benzyl ester acrylate (generic). (a) Chemical substance... halogenated benzyl ester acrylate (PMN P-90-1527) is subject to reporting under this section for...

  15. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  16. 40 CFR 721.10180 - Trifunctional acrylic ester (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Trifunctional acrylic ester (generic... Specific Chemical Substances § 721.10180 Trifunctional acrylic ester (generic). (a) Chemical substance and... acrylic ester (PMN P-04-692) is subject to reporting under this section for the significant new...

  17. 40 CFR 721.10477 - Acrylate ester (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate ester (generic). 721.10477... Substances § 721.10477 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-04-290) is subject...

  18. 40 CFR 721.10477 - Acrylate ester (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate ester (generic). 721.10477... Substances § 721.10477 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-04-290) is subject...

  19. 40 CFR 721.10537 - Acrylate ester (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate ester (generic). 721.10537... Substances § 721.10537 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-01-579) is subject...

  20. 40 CFR 721.10537 - Acrylate ester (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate ester (generic). 721.10537... Substances § 721.10537 Acrylate ester (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as acrylate ester (PMN P-01-579) is subject...

  1. 40 CFR 721.329 - Halogenated benzyl ester acrylate (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Halogenated benzyl ester acrylate... Specific Chemical Substances § 721.329 Halogenated benzyl ester acrylate (generic). (a) Chemical substance... halogenated benzyl ester acrylate (PMN P-90-1527) is subject to reporting under this section for...

  2. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  3. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  4. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Nickel acrylate complex. 721.5325... Substances § 721.5325 Nickel acrylate complex. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance nickel acrylate complex (PMN P-85-1034) is subject to reporting...

  5. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ethylene-ethyl acrylate copolymers. 177.1320... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1320 Ethylene-ethyl acrylate copolymers. Ethylene-ethyl acrylate copolymers may be safely used to produce packaging materials,...

  6. 21 CFR 177.1310 - Ethylene-acrylic acid copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ethylene-acrylic acid copolymers. 177.1310 Section... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1310 Ethylene-acrylic acid copolymers. The ethylene-acrylic acid copolymers identified in paragraph (a) of this section may be...

  7. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ethylene-ethyl acrylate copolymers. 177.1320... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1320 Ethylene-ethyl acrylate copolymers. Ethylene-ethyl acrylate copolymers may be safely used to produce packaging materials,...

  8. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ethylene-ethyl acrylate copolymers. 177.1320... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1320 Ethylene-ethyl acrylate copolymers. Ethylene-ethyl acrylate copolymers may be safely used to produce packaging materials,...

  9. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as...

  10. 21 CFR 177.1060 - n-Alkylglutarimide/acrylic copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true n-Alkylglutarimide/acrylic copolymers. 177.1060... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1060 n-Alkylglutarimide/acrylic copolymers. n-Alkylglutarimide/acrylic copolymers identified in this section may be safely used as articles...

  11. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate polymer...

  12. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate polymer...

  13. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate polymer...

  14. The Edge

    NASA Technical Reports Server (NTRS)

    2006-01-01

    6 April 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows the edge (running diagonally from the lower left to the upper right) of a trough, which is part of a large pit crater complex in Noachis Terra. This type of trough forms through the collapse of surface materials into the subsurface, and often begins as a series of individual pit craters. Over time, continued collapse increases the diameter of individual pits until finally, adjacent pits merge to form a trough such as the one captured in this image. The deep shadowed area is caused in part by an overhang; layered rock beneath this overhang is less resistant to erosion, and thus has retreated tens of meters backward, beneath the overhang. A person could walk up inside this 'cave' formed by the overhanging layered material.

    Location near: 47.0oS, 355.7oW Image width: 3 km (1.9 mi) Illumination from: upper left Season: Southern Summer

  15. Acrylic Tanks for Stunning Chemical Demonstrations

    ERIC Educational Resources Information Center

    Mirholm, Alexander; Ellervik, Ulf

    2009-01-01

    We describe the use of acrylic tanks (400 x 450 x 27 mm) for visualization of chemical demonstrations in aqueous solutions. Examples of well-suited demonstrations are oscillating reactions, pH indicators, photochemical reduction of Lauth's violet, and chemoluminiscent reactions. (Contains 1 figure.)

  16. Mechanical Force Sensitive Acrylic Latex Coating.

    PubMed

    Li, Meng; Liu, Weifeng; Zhang, Qi; Zhu, Shiping

    2017-05-03

    We prepared force sensitive acrylic latex coatings by covalently incorporating spiropyran mechanophore. The acrylic latexes were obtained through emulsion copolymerization of butyl acrylate (BA), methyl methacrylate (MMA) with vinyltriethoxysilane (VTES) as interparticle cross-linker, and (1'-(2-(methacryloyloxy)ethyl)-3',3'-dimethylspiro[chromene-2,2'-indolin]-6-yl)methyl methacrylate) (SP) as intraparticle cross-linker. The latexes of P(BA-co-MMA-co-SP-co-VTES) were subsequently cast onto Teflon-coated surface to form latex coatings. The condensation of hydrolyzed VTES provided interparticle cross-linking and improved mechanical properties of the formed thin films. Intraparticle cross-linker SP endowed the coatings with mechanoreponsiveness. The mechanoactivation of SP-containing latex films was demonstrated. Increasing the content of intra-cross-linker SP resulted in higher stress sensitivity and lower critical stress required for mechanoactivation. Increasing the content of interparticle cross-linker VTES resulted in higher critical stress for SP mechanoactivation but had little effect on the stress sensitivity. Tg and operation temperature also showed significant effect on mechanoactivation. Slower strain rate allowed for higher SP-to-MC conversion. This work represents the first example of mechanochromic acrylic latexes and provides insight into the design of force sensitive and self-reporting polymer coatings.

  17. Structure-toxicity relationships of acrylic monomers.

    PubMed Central

    Autian, J

    1975-01-01

    Esters of acrylic acid, in particular methyl methacrylate, have wide applications in a number of industrial and consumer products, forming very desirable nonbreakable glass-like materials. In dentistry, the monomers are used to prepare dentures and a variety of filling and coating materials for the teeth. Surgeons utilize the monomers to prepare a cement which helps anchor prosthetic devices to bone. Special types of acrylic monomers such as the cyano derivatives have found a useful application as adhesive materials. Most of the acrylic acid esters are volatile substances and can produce various levels of toxicity if inhaled. A large number of workers thus exposed to the vapors of these esters can develop clinical symptoms and signs of toxicity. This paper will discuss the toxicity of a large number of acrylic esters, and will attempt to show structure-activity relationships where such data are available. General comments will also be made as to the potential health hazards this variety of esters may present to selected segments of the population. PMID:1175551

  18. 40 CFR 721.2805 - Acrylate ester.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.2805 Acrylate ester. Link to an amendment published at 79 FR 34637, June 18, 2014. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as an...

  19. Stainless steel mesh-acrylic cranioplasty.

    PubMed

    Tysvaer, A T; Hovind, K H

    1977-03-01

    Twenty-four steel mesh-acrylic plates have been used for repair of skull defects in 1970-73. Three plates had to be removed due to complications, two due to infection and one due to an allergic reaction. The plate is easy to mould, strong, and light. The cosmetic results are excellent.

  20. Acrylic Tanks for Stunning Chemical Demonstrations

    ERIC Educational Resources Information Center

    Mirholm, Alexander; Ellervik, Ulf

    2009-01-01

    We describe the use of acrylic tanks (400 x 450 x 27 mm) for visualization of chemical demonstrations in aqueous solutions. Examples of well-suited demonstrations are oscillating reactions, pH indicators, photochemical reduction of Lauth's violet, and chemoluminiscent reactions. (Contains 1 figure.)

  1. Efficient enzymatic acrylation through transesterification at controlled water activity.

    PubMed

    Nordblad, Mathias; Adlercreutz, Patrick

    2008-04-15

    Enzymatic acrylation is a process of potentially strong interest to the chemical industry. Direct esterification involving acrylic acid is unfortunately rather slow, with inhibition phenomena appearing at high acid concentrations. In the present study the acrylation of 1-octanol catalyzed by immobilized Candida antarctica lipase B (Novozym 435) was shown to be as much as an order of magnitude faster when ethyl acrylate served as the donor of the acrylic group. Water activity is a key parameter for optimizing the rate of ester synthesis. The optimum water activity for the esterification of octanol by acrylic acid was found to be 0.75, that for its esterification by propionic acid to be 0.45 and the transesterification involving ethyl acrylate to be fastest at a water activity of 0.3. The reasons for these differences in optimum water activity are discussed in terms of enzyme specificity, substrate solvation, and mass transfer effects.

  2. Large Acrylic Spherical Windows In Hyperbaric Underwater Photography

    NASA Astrophysics Data System (ADS)

    Lones, Joe J.; Stachiw, Jerry D.

    1983-10-01

    Both acrylic plastic and glass are common materials for hyperbaric optical windows. Although glass continues to be used occasionally for small windows, virtually all large viewports are made of acrylic. It is easy to uderstand the wide use of acrylic when comparing design properties of this plastic with those of glass, and glass windows are relatively more difficult to fabricate and use. in addition there are published guides for the design and fabrication of acrylic windows to be used in the hyperbaric environment of hydrospace. Although these procedures for fabricating the acrylic windows are somewhat involved, the results are extremely reliable. Acrylic viewports are now fabricated to very large sizes for manned observation or optical quality instrumen tation as illustrated by the numerous acrylic submersible vehicle hulls for hu, an occupancy currently in operation and a 3600 large optical window recently developed for the Walt Disney Circle Vision under-water camera housing.

  3. Quantitative analysis of posterior capsule opacification of hydrophobic acrylic intraocular lenses.

    PubMed

    Oharazawa, Hideaki; Suzuki, Hisaharu; Shibata, Keiko; Yamada, Yumi; Matsui, Hironori; Shiwa, Toshihiko; Takahashi, Hiroshi; Ohara, Kunitoshi

    2007-02-01

    Posterior capsule opacification (PCO) remains a common complication of modern cataract surgery, although both modification of materials used and changes in the intraocular lens (IOL) optic edge design have helped to decrease its incidence slightly. Recently, various kinds of quantitative methods have been developed for measuring PCO. The purpose of this study was to compare the quantitative analysis of PCO between different types of IOL designs. Patients enrolled in the study had age-related cataract and underwent uneventful cataract surgery and implantation of either the AcrySof MA30BA (Alcon) or the Sensor AR40e (AMO), which are differently designed hydrophobic acrylic IOLs with a sharp-edged optic design. Postoperative examination was performed at 6 months. Retroillumination photographs of each eye were obtained, and the degree of PCO was assessed using the Evaluation of Posterior Capsule Opacification (EPCO) system. Grade 1 PCO was noted in both the MA30BA and the AR40e groups. There was no significant difference in the mean PCO score between the MA30BA and AR40e groups. Although the sharp-edged optic designs of both IOLs might similarly inhibit PCO at 6 months, a long-term follow-up period is needed to determine if any PCO differences occur between these 2 hydrophobic acrylic IOLs.

  4. Experimental investigation on mechanism of hydrophilic acrylic intraocular lens calcification.

    PubMed

    Drimtzias, Evangelos G; Rokidi, Stamatina G; Gartaganis, Sotirios P; Koutsoukos, Petros G

    2011-11-01

    To construct a model simulating intraocular lens (IOL) opacification attributable to the formation of calcium phosphate deposits and to investigate the kinetics of deposit formation. Prospective laboratory investigation. Department of Ophthalmology, Medical School and Department of Chemical Engineering, Laboratory of Inorganic and Analytical Chemistry, University of Patras, Greece. Three hydrophilic acrylic IOLs (26% water content) were placed inside a 10-mL double-walled thermostated reactor simulating the anterior chamber. Simulated aqueous humor was injected continuously into the reactor using a pump with variable speed. The observation of IOLs was carried out in situ daily by optical microscopy. Scanning electron microscopy and energy-dispersive radiographic spectroscopy were used for the identification of the morphologic features and the composition of the deposits. The lenses were removed and inspected 5, 9, and 12 months after the initiation of the experiment. Investigation showed deposits of calcium phosphate crystallites in the interior of opacified IOLs. However, these deposits were not observed on the surface of the IOLs. In agreement with earlier reports by our group and in the literature, IOL opacification is the result of calcification. It is suggested that the surface hydroxyl groups of the polyacrylic polymeric components of the IOLs are capable of inducing surface nucleation and crystal growth of calcium phosphates. However, most important is the finding that the calcification of IOLs is initiated from their interior through the development of sufficiently high local supersaturation, realized through the diffusion of calcium and phosphate ions. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Glistenings 9 years after phacoemulsification in hydrophobic and hydrophilic acrylic intraocular lenses.

    PubMed

    Chang, Anthony; Kugelberg, Maria

    2015-06-01

    To compare the development of glistenings after implantation of a hydrophobic acrylic intraocular lens (IOL) (AcrySof SA60AT) and a hydrophilic IOL (BL27) and evaluate the effect on corrected distance visual acuity (CDVA) and contrast sensitivity 9 years postoperatively. St. Erik Eye Hospital, Stockholm, Sweden. Prospective randomized clinical trial. One of 3 experienced cataract surgeons performed standard phacoemulsification in 1 eye of each patient. The patients were randomized to implantation of a hydrophobic acrylic IOL or a hydrophilic acrylic IOL. Both IOLs had sharp posterior edges. The CDVA and contrast sensitivity were measured 9 years postoperatively. Scheimpflug images of the IOLs were obtained to analyze glistenings, which were graded subjectively at the slitlamp and quantified objectively with digital image analysis using computer software. Seventy-eight of the 120 patients were available for the 9-year follow-up examination. Patients with the hydrophilic IOL had statistically significantly fewer glistenings (P < .001). The development of glistenings was not correlated with IOL power, CDVA, or contrast sensitivity. After 9 years, the hydrophobic IOL developed more glistenings than the hydrophilic IOL. Glistenings did not affect CDVA or contrast sensitivity. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Acrylic emulsion binder for tape casting

    SciTech Connect

    Tang, X.; Ibbitson, S.A.; Donato, A.T.

    1996-06-01

    A crosslinkable acrylic emulsion binder has been demonstrated to significantly increase tensile strength of green tapes. A low Tg acrylic emulsion binder is blended with the crosslinkable binder to retain flexibility and elasticity of green tapes. The tensile strength of green tapes can be increased from 1.19 MPa to 2.34 MPa by incorporating a crosslinkable binder into the formulation while the tapes remain flexible and elastic with {approximately}15% strain at break. Upon stretching, the green tapes do not yield before breaking. Increasing the drying temperature appears to slightly increase the tensile strength of the green tapes, and has a marginal effect on the strain at break of the tapes. This binder system does not liberate formaldehyde as a result of crosslinking.

  7. Multiple Internal Reflections in Acrylic Triangle Waveguide

    NASA Astrophysics Data System (ADS)

    Marzuki, A.; Setiawan, D.; Purwanto, H.; Yunianto, M.

    2016-11-01

    Theoretical and experimental study of light propagation in acrylic triangle waveguides has been studied theoretically and experimentally aimed to obtain a light cone which can tunnel and bring the light to a certain place. Numerical aperture of light cones which have a length of 7 cm but different cross-section area have been measured using he-Ne laser (λ=632 nm) and the results were compared to those obtained theoretically and no significant different was observed.

  8. 'Weightless' acrylic painting by Jack Kroehnke

    NASA Technical Reports Server (NTRS)

    1987-01-01

    'Weightless' acrylic painting by Jack Kroehnke depicts STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) David C. Hilmers participating in extravehicular activity (EVA) simulation in JSC Weightless Environment Training Facility (WETF) Bldg 29. In the payload bay (PLB) mockup, Hilmers, wearing extravehicular mobility unit (EMU), holds onto the mission-peculiar equipment support structure in foreground while SCUBA-equipped diver monitors activity overhead and camera operator records EVA procedures. Copyrighted art work for use by NASA.

  9. Modeling the free radical polymerization of acrylates

    NASA Astrophysics Data System (ADS)

    Günaydin, Hakan; Salman, Seyhan; Tüzün, Nurcan Şenyurt; Avci, Duygu; Aviyente, Viktorya

    Acrylates have gained importance because of their ease of conversion to high-molecular-weight polymers and their broad industrial use. Methyl methacrylate (MMA) is a well-known monomer for free radical polymerization, but its α-methyl substituent restricts the chemical modification of the monomer and therefore the properties of the resulting polymer. The presence of a heteroatom in the methyl group is known to increase the polymerizability of MMA. Methyl α-hydroxymethylacrylate (MHMA), methyl α-methoxymethylacrylate (MC1MA), methyl α-acetoxymethylacrylate (MAcMA) show even better conversions to high-molecular-weight polymers than MMA. In contrast, the polymerization rate is known to decrease as the methyl group is replaced by ethyl in ethyl α-hydroxymethylacrylate (EHMA) and t-butyl in t-butyl α-hydroxymethylacrylate (TBHMA). In this study, quantum mechanical tools (B3LYP/6-31G*) have been used in order to understand the mechanistic behavior of the free radical polymerization reactions of acrylates. The polymerization rates of MMA, MHMA, MC1MA, MAcMA, EHMA, TBHMA, MC1AN (α-methoxymethyl acrylonitrile), and MC1AA (α-methoxymethyl acrylic acid) have been evaluated and rationalized. Simple monomers such as allyl alcohol (AA) and allyl chloride (AC) have also been modeled for comparative purposes.

  10. ICI/BASF PP for acrylics swap

    SciTech Connect

    Alperowicz, N.

    1993-01-27

    ICI (London) and BASF (Ludwigshafen) have announced their long-awaited polypropylene (PP) for acrylics swap deal. ICI is buying BASF's European acrylic resin business, and the German firm will acquire ICI's European PP operations. The deal is due for completion by mid-1993, subject to regulatory approvals. BASF, hitherto a small-scale PP producer, doubles capacity to 600,000 m.t./year and moves up the European PP league to number three, behind Himont and Shell. BASF, whose process is used in the plants, secures a foothold in the UK PP market, where Shell - planning a merger with Himont - is the only other producer, with 170,000 m.t./year. ICI's purchase involves BASF's Resart GmbH and Critesa SA subsidiaries, located at Mainz, Germany and near Barcelona, Spain, respectively. The business - which will add about [Brit pounds]60 million ($93 million) to ICI Acrylics [Brit pounds]300-million revenues - employs 400 people, who will transfer to ICI.

  11. Bilateral Anterior Shoulder Dislocation

    PubMed Central

    Siu, Yuk Chuen; Lui, Tun Hing

    2014-01-01

    Introduction: Unilateral anterior shoulder dislocation is one of the most common problems encountered in orthopedic practice. However, simultaneous bilateral anterior dislocation of the shoulders is quite rare. Case Presentation: We report a case of a 75-year-old woman presented with simultaneous bilateral anterior shoulder dislocation following a trauma, complicated with a traction injury to the posterior cord of the brachial plexus. Conclusions: Bilateral anterior shoulder dislocation is very rare. The excessive traction force during closed reduction may lead to nerve palsy. Clear documentation of neurovascular status and adequate imaging before and after a reduction should be performed. PMID:25685749

  12. Palladium (II) catalyized polymerization of norbornene and acrylates

    DOEpatents

    Sen, Ayusman; Kacker, Smita; Hennis, April; Polley, Jennifer D.

    2000-08-29

    Homopolymers or copolymers of acrylates, homopolymers or copolymers of norbornenes, and copolymers of acrylates with norbornenes, may be prepared by contacting acrylate and/or norbornene monomer reactant under polymerization conditions and in the presence of a solvent with a catalyst system consisting essentially of a Pd(II) dimer component having the formula: [(L)Pd(R)(X)].sub.2, where L is a monodentate phosphorus or nitrogen ligand, X is an anionic group, and R is an alkyl or aryl group.

  13. Palladium (Ii) Catalyzed Polymerization Of Norbornene And Acrylates

    DOEpatents

    Sen, Ayusman; Kacker, Smita; Hennis, April; Polley, Jennifer D.

    2001-10-09

    Homopolymers or copolymers of acrylates, homopolymers or copolymers of norbornenes, and copolymers of acrylates with norbornenes, may be prepared by contacting acrylate and/or norbornene monomer reactant under polymerization conditions and in the presence of a solvent with a catalyst system consisting essentially of a Pd(II) dimer component having the formula: where L is a monodentate phosphorus or nitrogen ligand, X is an anionic group, and R is an alkyl or aryl group.

  14. [Incomplete anterior interosseous nerve syndrome in a guitar player].

    PubMed

    Rieck, B

    2005-12-01

    A rare case of median nerve compression syndrome is reported in a guitar player who had changed the posture and position of his instrument so that the edge of the guitar exerted sharp pressure on the median nerve close to the branching of the interosseous anterior nerve. There was partial paralysis of the interosseous anterior nerve with complete failure of the deep flexor of the index finger, while the flexor pollicis longus was intact. There was also paresthesia of the index finger. Treatment was conservative with a sleeve including a gel cushion which protected the forearm against the edge of the instrument. Function recurred completely within six weeks without ever interrupting instrument practice.

  15. Kinetics and products of gas-phase reactions of ozone with methyl methacrylate, methyl acrylate, and ethyl acrylate.

    PubMed

    Bernard, F; Eyglunent, G; Daële, V; Mellouki, A

    2010-08-19

    The kinetics and products of the gas-phase reactions of ozone with methyl methacrylate, methyl acrylate, and ethyl acrylate have been investigated at 760 Torr total pressure of air and 294 +/- 2 K. The rate coefficients obtained (in cm(3) molecule(-1) s(-1) units) were as follows: k(methyl methacrylate) = (6.7 +/- 0.9) x 10(-18), k(methyl acrylate) = (0.95 +/- 0.07) x 10(-18), and k(ethyl acrylate) = (1.3 +/- 0.1) x 10(-18). In addition to formaldehyde being observed as a product of the three reactions, the other major reaction products were methyl pyruvate from reaction of ozone with methyl methacrylate, methyl glyoxylate from reaction of ozone with methyl acrylate, and ethyl glyoxylate from reaction of ozone with ethyl acrylate. Possible reaction mechanisms leading to the observed products are presented and discussed.

  16. The effect of posterior spinal fixation with acrylic cement on the vertebral growth plate and intervertebral disc in dogs.

    PubMed

    Moon, M S; Ok, I Y; Ha, K Y

    1986-01-01

    We have attempted to clarify the serial histological changes in the growing spine of dogs following posterior fixation with acrylic cement. Twenty-four male mongrel dogs aged 8 weeks were used for the study. The lumbar spine from L.3 to L.5 was fixed posteriorly with acrylic cement. Three dogs were then sacrificed every four weeks up to 32 weeks, and the histological changes of the vertebral disc, growth plate and vertebral bodies were observed by light microscopy. Thinning of the growth plate and distortion of the cartilage columns has been demonstrated, but premature fusion of the growth plate did not result and vertebral body growth continued. Anterior wedging of the intervertebral disc was seen with some thinning of the bony trabeculae of the vertebral body. Degeneration of the nucleus pulposus resulted, with replacement by fibrous tissue. The normal horizontal arrangement of the fibres of the annulus fibrosus altered to a vertical configuration by 32 weeks.

  17. Randomized SUSAN edge detector

    NASA Astrophysics Data System (ADS)

    Qu, Zhi-Guo; Wang, Ping; Gao, Ying-Hui; Wang, Peng

    2011-11-01

    A speed up technique for the SUSAN edge detector based on random sampling is proposed. Instead of sliding the mask pixel by pixel on an image as the SUSAN edge detector does, the proposed scheme places the mask randomly on pixels to find edges in the image; we hereby name it randomized SUSAN edge detector (R-SUSAN). Specifically, the R-SUSAN edge detector adopts three approaches in the framework of random sampling to accelerate a SUSAN edge detector: procedure integration of response computation and nonmaxima suppression, reduction of unnecessary processing for obvious nonedge pixels, and early termination. Experimental results demonstrate the effectiveness of the proposed method.

  18. Assessment of anterior suspended flaps modification for external dacryocystorhinostomy.

    PubMed

    Tetikoglu, Mehmet; Sagdik, Haci Murat; Ozcura, Fatih; Aktas, Serdar

    2015-05-01

    The aim of this study was to evaluate the functional and/or anatomic success rate as well as complications of anterior suspended flaps modification for external dacryocystorhinostomy (DCR). This is a retrospective study that included 50 eyes of 47 patients who underwent anterior suspended flap external DCR surgery for nasolacrimal duct obstruction. Diagnosis of nasolacrimal duct obstruction was made through irrigation of the nasolacrimal drainage system. Anterior flaps of lacrimal sac and nasal mucosa, as large as possible, were created in all patients. Posterior flaps of lacrimal sac and exposed nasal mucosa were excised. After suturing the anterior flaps with two 6-0 Vicryl sutures, the third suture was passed through the orbicularis oculi at the subcutaneous level on 1 edge of incision, then from the middle of the anterior flaps and the other edge of the incision to the suspended anterior flaps. The success rate of 50 surgeries was 96%. In 37 eyes, no problems were reported during the surgery and the modified external DCR was performed successfully. The success rate of the modified external DCR was 100% in those patients. The average operation time was 34 ± 8.2 minutes. These results suggest that anterior suspended flap external DCR is a simple, safe technique with a very high success rate and a satisfactory surgical time.

  19. Improved Acrylic Systems for Rapid Runway Repair.

    DTIC Science & Technology

    1983-05-01

    Concrete * Fast-Setting Concrete N Acrylic Polymer Research * 1 k UST mACV lC@ea. ON -- -0 - OW. 00....Y d*Ip OF 40 domb) The objectives of this...available to the general public, including foreign nationals. This technical report has been reviewed and is approved for publication. DANIEL J. PIERRE, Capt...resins. The aggregate and resin might be premixed for placement or (as in the research reported herein) the cap might be formed by percolation of liquid

  20. Acrylic Finger Prosthesis: A Case Report

    PubMed Central

    Bandela, Vinod; M, Bharathi; S V, Giridhar Reddy

    2014-01-01

    Hands basic function is to grasp, hold and manipulate items. Hand gesture is perhaps the most blatant example of non-verbal communication. Finger and partial finger amputations are most frequently encountered forms of partial hand loss. Common causes are traumatic injuries, congenital absence or malformations present great clinical challenges. In addition to immediate loss of grasp strength, finger absence may cause marked psychological trauma. Individuals who desire finger replacement usually have high expectation for the appearance of prosthesis. This clinical report portrays simple method to retain acrylic finger prosthesis. PMID:25302271

  1. Comparison of Candida Albicans Adherence to Conventional Acrylic Denture Base Materials and Injection Molding Acrylic Materials

    PubMed Central

    Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh

    2017-01-01

    Statement of the Problem: Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. Purpose: The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Materials and Method: Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer’s instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×108 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Results: Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×103) comparing to injection molding acrylic resins (6×103) were statistically significant (p<0.001). Conclusion: Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis. PMID:28280761

  2. Anterior cruciate ligament (ACL) injury

    MedlinePlus

    Cruciate ligament injury - anterior; ACL injury; Knee injury - anterior cruciate ligament (ACL) ... knee. It prevents the knee from bending out. Anterior cruciate ligament (ACL) is in the middle of the knee. ...

  3. Anterior Cruciate Ligament (ACL) Injuries

    MedlinePlus

    ... Week of Healthy Breakfasts Shyness Anterior Cruciate Ligament (ACL) Injuries KidsHealth > For Teens > Anterior Cruciate Ligament (ACL) ... and Recovery Coping With an ACL Injury About ACL Injuries A torn anterior cruciate ligament (ACL) is ...

  4. Dilemmas in Treatment of Recurrent Recalcitrant Dental Anterior Open Bite.

    PubMed

    Palencar, Adrian J

    2016-01-01

    An anterior open bite is one of the most difficult occlusal abnormalities to treat. Quite often this aberration entails dental component and/or skeletal component. The skeletal open bite will require intrusion of the posterior sextants with the assistance of bite blocks, temporary anchorage devices, high pull headgear, and as a last resort - orthognathic surgery. The orthodontic treatment should be augmented with the orofacial myofunctional therapy. In this article, the author describes 3 different variations of treatment of the dental anterior open bite, first on acrylic models, and then on the actual patients. Consideration should be given to patients with a 'short upper lip," and in this case, surgical correction should be entertained.

  5. [Anterior tarsal tunnel syndrome].

    PubMed

    Miliam, Palle B; Basse, Peter N

    2009-03-30

    Anterior tarsal tunnel syndrome is a rare entrapment neuropathy of the deep peroneal nerve beneath the extensor retinaculum of the ankle. It may be rare because it is underrecognized clinically.We present a case regarding a 29-year-old man, drummer, who for one and a half year experienced clinical symptoms of anterior tarsal tunnel syndrome. A surgical decompression of the anterior tarsal tunnel was performed, and at the check three months later the symptoms where gone. One year after, there were still no symptoms.

  6. [Isolated anterior cervical hypertrichosis].

    PubMed

    Monteagudo, B; Cabanillas, M; de las Heras, C; Cacharrón, J M

    2009-01-01

    Anterior cervical hypertrichosis was described by Trattner and coworkers in 1991. It consists of a of hair at the anterior cervical level just above the laryngeal prominence. To date, only 28 cases of anterior cervical hypertrichosis have been reported. Although it is normally an isolated finding, it may be associated with mental retardation, hallux valgus, retinal disorders, other hair disorders, facial dysmorphism, or sensory and motor peripheral neuropathy. We report the case of a 27-year-old woman who presented with this condition as an isolated finding.

  7. Acrylic coatings with surprising antifogging and frost-resisting properties.

    PubMed

    Zhao, Jie; Meyer, Anthony; Ma, Li; Ming, Weihua

    2013-12-28

    We report an unusually effective antifogging/frost-resisting coating based on conventional acrylic polymers. The intriguing antifogging property originated from the delicate balance between the hydrophilicity and hydrophobicity of the acrylic copolymers of 2-(dimethylamino)ethyl methacrylate and methyl methacrylate, as well as between the water-swellability of the copolymer and the cross-linked network due to ethylene glycol dimethacrylate.

  8. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  9. 40 CFR 721.8082 - Polyester polyurethane acrylate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Polyester polyurethane acrylate. 721... Substances § 721.8082 Polyester polyurethane acrylate. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as polyester polyurethane...

  10. Filled Cold-Curing Acrylic Resin as a Splinting Material.

    DTIC Science & Technology

    polymethylmethacrylate plus sufficient methyl methacrylate monomer to form a dough. This filled acrylic resin composition is useful in dental splinting...methods. Also disclosed is a dental splinting method employing this filled acrylic resin composition in combination with interproximal pins and an elastic connector.

  11. 40 CFR 721.10500 - Acrylated mixed metal oxides (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylated mixed metal oxides (generic... Specific Chemical Substances § 721.10500 Acrylated mixed metal oxides (generic). (a) Chemical substance and... mixed metal oxides (PMN P-06-341) is subject to reporting under this section for the significant...

  12. 40 CFR 721.10500 - Acrylated mixed metal oxides (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylated mixed metal oxides (generic... Specific Chemical Substances § 721.10500 Acrylated mixed metal oxides (generic). (a) Chemical substance and... mixed metal oxides (PMN P-06-341) is subject to reporting under this section for the significant...

  13. The Acrylation of Glycerol: a Precursor to Functionalized Lipids

    USDA-ARS?s Scientific Manuscript database

    Didecanoylacryloylglycerol was synthesized from decanoic and acrylic acids and glycerol using K2O as catalyst. This reaction was carried out in hexane in a closed stainless steel reactor at 200°C for 5h. The reactants were added in a 1:3:4 glycerol:decanoic acid:acrylic acid molar ratio. The resu...

  14. FIXED OR REMOVABLE APPLIANCE FOR EARLY ORTHODONTIC TREATMENT OF FUNCTIONAL ANTERIOR CROSSBITE.

    PubMed

    Wiedel, Anna-Paulina

    2015-01-01

    Anterior crossbite with functional shift also called pseudo Class III is a malocclusion in which the incisal edges of one or more maxillary incisors occlude with the incisal edges of the mandibular incisors in centric relationship: the mandible and mandibular incisors are then guided anteriorly in central occlusion resulting in an anterior crossbite. Early correction, at the mixed dentition stage, is recommended, in order to avoid a compromising dentofacial condition which could result in the development of a true Class III malocclusion and temporomandibular symptoms. Various treatment options are available. The method of choice for orthodontic correction of this condition should not only be clinically effective, with long-term stability, but also cost-effective and have high patient acceptance, i.e. minimal perceived pain and discomfort. At the mixed dentition stage, the condition may be treated by fixed (FA) or removable appliance (RA). To date there is insufficient evidence to determine the preferred method. The overall aim of this thesis was therefore to compare and evaluate the use of FA and RA for correcting anterior crossbite with functional shift in the mixed dentition, with special reference to clinical effectiveness, stability, cost-effectiveness and patient perceptions. Evidence-based, randomized controlled trial (RCT) methodology was used, in order to generate a high level of evidence. The thesis is based on the following studies: The material comprised 64 patients, consecutively recruited from the Department of Orthodontics, Faculty of Odontology, Malmö University, Sweden and from one Public Dental Health Service Clinic in Malmö, Skane County Council, Sweden. The patients were no syndrome and no cleft patients. The following inclusion criteria were applied: early to late mixed dentition, anterior crossbite affecting one or more incisors with functional shift, moderate space deficiency in the maxilla, no inherent skeletal Class III discrepancy, ANB

  15. Nanoindentation near the edge

    Treesearch

    J.E. Jakes; C.R. Frihart; J.F. Beecher; R.J. Moon; P.J. Resto; Z.H. Melgarejo; O.M. Saurez; H. Baumgart; A.A. Elmustafa; D.S. Stone

    2009-01-01

    Whenever a nanoindent is placed near an edge, such as the free edge of the specimen or heterophase interface intersecting the surface, the elastic discontinuity associated with the edge produces artifacts in the load-depth data. Unless properly handled in the data analysis, the artifacts can produce spurious results that obscure any real trends in properties as...

  16. Allergic contact dermatitis from acrylic nails in a flamenco guitarist.

    PubMed

    Alcántara-Nicolás, F A; Pastor-Nieto, M A; Sánchez-Herreros, C; Pérez-Mesonero, R; Melgar-Molero, V; Ballano, A; De-Eusebio, E

    2016-12-01

    Acrylates are molecules that are well known for their strong sensitizing properties. Historically, many beauticians and individuals using store-bought artificial nail products have developed allergic contact dermatitis from acrylates. More recently, the use of acrylic nails among flamenco guitarists to strengthen their nails has become very popular. A 40-year-old non-atopic male patient working as a flamenco guitarist developed dystrophy, onycholysis and paronychia involving the first four nails of his right hand. The lesions were confined to the fingers where acrylic materials were used in order to strengthen his nails to play the guitar. He noticed improvement whenever he stopped using these materials and intense itching and worsening when he began reusing them. Patch tests were performed and positive results obtained with 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxyethyl acrylate (2-HEA), ethyleneglycol-dimethacrylate (EGDMA) and 2-hydroxypropyl methacrylate (2-HPMA). The patient was diagnosed with occupational allergic contact dermatitis likely caused by acrylic nails. Artificial nails can contain many kinds of acrylic monomers but most cases of contact dermatitis are induced by 2-HEMA, 2-HPMA and EGDMA. This is the first reported case of occupational allergic contact dermatitis from acrylates in artificial nails in a professional flamenco guitar player. Since the practice of self-applying acrylic nail products is becoming very popular within flamenco musicians, we believe that dermatology and occupational medicine specialists should be made aware of the potentially increasing risk of sensitization from acrylates in this setting. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Anterior temporalis and suprahyoid EMG activity during jaw clenching and tooth grinding.

    PubMed

    Aldana, Karina; Miralles, Rodolfo; Fuentes, Aler; Valenzuela, Saúl; Fresno, María Javiera; Santander, Hugo; Gutiérrez, Mario Felipe

    2011-10-01

    The aim of this study was to evaluate the anterior temporalis and suprahyoid electromyographic (EMG) activity during jaw clenching and tooth grinding at different jaw posture tasks. The study included 30 healthy subjects with natural dentition and bilateral molar support, incisive protrusive guidance and bilateral laterotrusive canine guidance. Bipolar surface electrodes were located on the right anterior temporalis and suprahyoid muscles. Three EMG recordings in the standing position were performed in the following tasks: C. clenching in the intercuspal position (IP); P1. eccentric grinding from IP to protrusive edge-to-edge contact position; P2. clenching in protrusive edge-to-edge contact position; P3. concentric grinding from protrusive edge-to-edge contact position to IP; L1. eccentric grinding from IP to laterotrusive edge-to-edge contact position; L2. clenching in laterotrusive edge-to-edge contact position; L3. concentric grinding from laterotrusive edge-to-edge contact position to IP. EMG activity during protrusive and laterotrusive tasks was lower than intercuspal position in the anterior temporalis, whereas an opposite EMG pattern was observed in the suprahyoid muscles activity, excepting recorded activity in L2 (mixed model with unstructured covariance matrix). Anterior temporalis activity was higher during P3 than P1 and P2 tasks and during L3 than L1 and L2 tasks, whereas in the suprahyoid muscles, activity was higher during P1 than P2 tasks and during L1 than L2 and L3 tasks. These results could support the idea of a differential modulation of the motor neuron pools of anterior temporalis and suprahyoid muscles of peripheral and/or central origin.

  18. How I do it: epidural anterior petrosectomy.

    PubMed

    Roche, Pierre-Hugues; Lubrano, Vincent F; Noudel, Rémy

    2011-06-01

    Among the potential approaches to access the petroclival area, epidural anterior petrosectomy (EAP) appears to be the most direct and conservative transpetrous route. In this article, we aim to detail the relevant surgical steps necessary to perform EAP in a reproducible and safe manner. The temporo-pterional bone flap is tailored to access the floor of the middle fossa and expose the foramen ovale and foramen spinosum. Elevation of the dura covering the upper surface of the petrous apex is conducted medially toward the level of the petrous ridge. Identification of the landmarks of the rhomboid fossa delineates the limits of the drilling zone (necessary for removal of the petrous apex)-beneath Meckel's cave and just anterior to the anterior margin of the internal auditory meatus. The tentorium is divided at its free edge and is followed by opening of the posterior fossa dura. Epidural anterior petrosectomy is a conservative trans-petrous approach that offers an excellent direct surgical corridor for exposure of disease processes involving Meckel's cave, the petroclival area and the ventrolateral pons.

  19. Ab initio study of acrylate polymerization reactions: methyl methacrylate and methyl acrylate propagation.

    PubMed

    Yu, Xinrui; Pfaendtner, Jim; Broadbelt, Linda J

    2008-07-24

    The kinetic parameters of the free radical propagation of methyl methacrylate and methyl acrylate have been calculated using quantum chemistry and transition state theory. Multiple density functional theory (DFT) methods were used to calculate the activation energy, and it was found that MPWB1K/6-31G(d,p) yields results that are in very good agreement with experimental data. To obtain values of the kinetic parameters that were in the best agreement with experimental data, low frequencies were treated using a one-dimensional internal rotor model. Chain length effects were also explored by examining addition reactions of monomeric, dimeric, and trimeric radicals to monomer for both methyl methacrylate and methyl acrylate. The results show that the values for the addition of the trimeric radical to monomer are closest to experimental data. The kinetic parameters that were calculated using a continuum description of the monomer as a solvent were not significantly different from the vacuum results.

  20. Early load mandibular hybrid prosthesis using the Ohio State University acrylic frame requiring no final impression.

    PubMed

    Turkyilmaz, I; Suarez, J C; Company, A M; McGlumphy, E A

    2009-09-01

    Although immediate/early loading protocols for dental implants have presented encouraging outcomes, immediate loading procedures may cause discomfort to the patient and may increase the possibility of damage to the surgical site during the impression procedures. The aim of this study was to describe an alternative technique to fabricate a mandibular hybrid prosthesis in three or four days without making any final impression and to evaluate the outcomes of this technique. Seven patients aged 41 to 71 years (mean age, 58 +/- 11) were considered for this study. Each patient received five implants for the reconstruction of the edentulous mandible. These implants were placed in the anterior region of an edentulous mandible and restored with a final mandibular hybrid prosthesis in four days using the Ohio State University (OSU) acrylic frame requiring no final impression procedure. The patients were followed up to 19 months after implant placement. No implants were lost, no technical complications were observed and only minor marginal bone loss was noted after an average 15 months. This clinical study shows that the OSU acrylic frame, which can easily be customized and accommodates variability in arch form, may be an alternative method to restore any edentulous mandible with an early load mandibular hybrid prosthesis.

  1. Opacification of two hydrophilic acrylic intraocular lenses 3 months after implantation.

    PubMed

    Macky, Tamer A; Werner, Liliana; Soliman, Mahmoud M; Pandey, Suresh K; Izak, Andrea M; Apple, David J

    2003-01-01

    To report clinical, pathologic, histochemical, ultrastructural, and spectrographic analyses of explanted hydrophilic acrylic intraocular lenses (IOLs) obtained from two patients who had early visual disturbances caused by postoperative opacification of the lens optic. Two hydrophilic IOLs were explanted from patients with decreased visual acuity. The patients became symptomatic 3 months after uneventful phacoemulsification and lens implantation. IOL optic opacification was associated with a fine granularity within the substance of the lens optic. The IOLs were examined by gross and light microscopy. Full-thickness cut sections of the optics were stained with 1% alizarin red (a special stain for calcium). Some sections were submitted for scanning electron microscopy and energy dispersive x-ray spectroscopy. Microscopic analyses revealed the presence of multiple fine, granular deposits of variable sizes within the optics of the lenses distributed in a line parallel to the anterior and posterior curvatures of the optic, with a clear zone just beneath the optics' surface. Extension of the opacification into the haptics of the IOLs could also be observed. The deposits stained positive with alizarin red. Energy dispersive x-ray spectroscopy of the internal substance of the IOLs also demonstrated the presence of calcium within the deposits. This is the first clinicopathologic report of optic and haptic opacification occurring with this hydrophilic acrylic IOL model only 3 months postoperatively. Further studies on other similar cases with this lens should be done to determine the incidence and possible mechanisms of this phenomenon.

  2. Calcification of a hydrophilic acrylic intraocular lens: case report with laboratory analysis.

    PubMed

    Bodnar, Z M; Rozot, P; Leishman, L; Ollerton, A; Michelson, J; Plasse-Fauque, S; Werner, L

    2013-09-01

    We analyzed a single-piece plate-type hydrophilic acrylic posterior chamber intraocular lens (IOL) that was explanted due to a progressive loss of vision, which occurred 6 years after uncomplicated phacoemulsification. Gross and light microscopy, as well as anterior segment optical coherence tomography (OCT) revealed granular deposits below the IOL surface. Light scattering, as measured with Scheimpflug photography and densitometry analyses was found to be increased; spectrophotometry demonstrated a decrease in the light transmittance of the explanted lens. The granular deposits within the IOL material were found to be composed of calcium by histochemical methods (alizarin red and Von Kossa stains). To our knowledge this is the only report of calcification of this IOL design. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. Electrochemical characterization of aminated acrylic conducting polymer

    SciTech Connect

    Rashid, Norma Mohammad; Heng, Lee Yook; Ling, Tan Ling

    2015-09-25

    New attempt has been made to synthesize aminated acrylic conducting polymer (AACP) using precursor of phenylvinylsulfoxide (PVS). The process was conducted via the integration of microemulsion and photopolymerization techniques. It has been utilized for covalent immobilization of amino groups by the adding of N-achryiloxisuccinimide (NAS). Thermal eliminating of benzene sulfenic acids from PVS has been done at 250 °C to form electroactive polyacetylene (PA) segment. Characterization of AACP has been conducted using fourier transform infrared (FTIR), scanning electron microscopy (SEM) and linear sweep cyclic voltammetry (CV). A range of 0.3-1.25μm particle size obtained from SEM characterization. A quasi-reversible system performed as shown in electrochemical study.

  4. Flexible, stretchable electroadhesives based on acrylic elastomers

    NASA Astrophysics Data System (ADS)

    Duduta, Mihai; Wood, Robert J.; Clarke, David R.

    2016-04-01

    Controllable adhesion is a requirement for a wide variety of applications including robotic manipulation, as well as locomotion including walking, crawling and perching. Electroadhesives have several advantages such as reversibility, low power consumption and controllability based on applied voltage. Most demonstrations of electroadhesive devices rely on fairly rigid materials, which cannot be stretched reversibly, as needed in some applications. We have developed a fast and reliable method for building soft, stretchable electroadhesive pads based on acrylic elastomers and electrodes made of carbon nanotubes. The devices produced were tested pre-deformation and in a stretched configuration. The adhesive force was determined to be in the 0.1 - 3.0 N/cm2 range, depending on the adhering surface. The electroadhesive devices were integrated with pre-stretched dielectric elastomer actuators to create a device in which the adhesion force could be tuned by changes in either the applied voltage or total area.

  5. Anterior segment optical coherence tomography in the assessment of postoperative intraocular lens optic changes.

    PubMed

    Werner, Liliana; Michelson, Jennifer; Ollerton, Andrew; Leishman, Lisa; Bodnar, Zachary

    2012-06-01

    To evaluate the use of anterior segment optical coherence tomography (AS-OCT) to assess postoperative intraocular lens (IOL) optic changes. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Intraocular lenses explanted because of various complications were used, including poly(methyl methacrylate) (PMMA) IOLs with snowflake degeneration, hydrophilic acrylic IOLs with calcification, a silicone IOL with calcification from an eye with asteroid hyalosis, and hydrophobic acrylic IOLs explanted because of decentration, subluxation, or uveitis-glaucoma-hyphema syndrome. After gross and light microscopy, the IOLs were examined in the dry and hydrated states using AS-OCT. Selected hydrophilic acrylic IOLs were stained for calcium. In-the-bag IOLs in pseudophakic cadaver eyes were also evaluated by AS-OCT before and after explantation to confirm correspondence with the clinical situation. Intraoptic changes, such as snowflake lesions in PMMA IOLs, calcification in hydrophilic acrylic IOLs, and glistenings in hydrophobic acrylic IOLs, could be imaged by AS-OCT. The method was also helpful in analyzing the location and density. However, in cases of more superficial changes, unless the lesions/deposits were present on the optic surface with an extension to the optic substance of at least 0.1 mm, they could not be clearly differentiated from the overall outline of the IOL surface. Anterior segment OCT may be helpful in assessing the presence, location, and density of intraoptic changes, avoiding a misdiagnosis of IOL opacification and the performance of unnecessary procedures, such as posterior capsulotomy or vitrectomy. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Methods for the synthesis of deuterated acrylate salts

    SciTech Connect

    Yang, Jun; Bonnesen, Peter V.; Hong, Kunlun

    2014-09-09

    A method for synthesizing a deuterated acrylate of the Formula (1), the method comprising: (i) deuterating a propiolate compound of Formula (2) to a methyne-deuterated propiolate compound of Formula (3) in the presence of a base and D.sub.2O: and (ii) reductively deuterating the methyne-deuterated propiolate compound of Formula (3) in a reaction solvent in the presence of deuterium gas and a palladium-containing catalyst to afford the deuterated acrylate of the Formula (1). The resulting deuterated acrylate compounds, derivatives thereof, and polymers derived therefrom are also described.

  7. Conversion of Lignocellulosic Biomass to Ethanol and Butyl Acrylate

    SciTech Connect

    Binder, Thomas; Erpelding, Michael; Schmid, Josef; Chin, Andrew; Sammons, Rhea; Rockafellow, Erin

    2015-04-10

    Conversion of Lignocellulosic Biomass to Ethanol and Butyl Acrylate. The purpose of Archer Daniels Midlands Integrated Biorefinery (IBR) was to demonstrate a modified acetosolv process on corn stover. It would show the fractionation of crop residue to distinct fractions of cellulose, hemicellulose, and lignin. The cellulose and hemicellulose fractions would be further converted to ethanol as the primary product and a fraction of the sugars would be catalytically converted to acrylic acid, with butyl acrylate the final product. These primary steps have been demonstrated.

  8. Fabrication and characterization of polyester and acrylic polyurethane optical waveguides.

    PubMed

    Kapoor, S K; Pandey, C D; Joshi, J C; Dawar, A L; Tripathy, K N; Gupta, V L

    1989-01-01

    Asystematic study of the fabrication and characterization of planar optical waveguides based on polyester and acrylic polyurethane coatings has been made. Mode effective refractive-index measurements have been made on a large number of these waveguides fabricated on glass prepared in different conditions. The results show that the mixture of polyester and acrylic polyol in the initial solution can be used to control the refractive index from 1.563 to 1.595. The propagation losses are estimated to be 10-20 and 6-12 dB/cm for polyester and acrylic-based waveguides, respectively.

  9. Investigation of Acrylic Acid at High Pressure Using Neutron Diffraction

    PubMed Central

    2014-01-01

    This article details the exploration of perdeuterated acrylic acid at high pressure using neutron diffraction. The structural changes that occur in acrylic acid-d4 are followed via diffraction and rationalized using the Pixel method. Acrylic acid undergoes a reconstructive phase transition to a new phase at ∼0.8 GPa and remains molecular to 7.2 GPa before polymerizing on decompression to ambient pressure. The resulting product is analyzed via Raman and FT-IR spectroscopy and differential scanning calorimetry and found to possess a different molecular structure compared with polymers produced via traditional routes. PMID:24650085

  10. Prevention of capsular bag opacification with a modified hydrophilic acrylic disk-shaped intraocular lens.

    PubMed

    Leishman, Lisa; Werner, Liliana; Bodnar, Zachary; Ollerton, Andrew; Michelson, Jennifer; Schmutz, Mason; Mamalis, Nick

    2012-09-01

    To evaluate the stability and capsular bag opacification with a modified disk-shaped 1-piece hydrophilic acrylic intraocular lens (IOL) suspended between 2 complete haptic rings connected by a pillar of the haptic material and with a commercially available 1-piece hydrophilic acrylic IOL. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Study and control IOLs were implanted into the left eyes and right eyes of 5 New Zealand rabbits. Eyes were examined at the slitlamp from 1 through 4 weeks. At 4 weeks, the globes were enucleated and evaluated under a very-high-frequency ultrasound. Photographs were taken and capsular bag opacification scored from the posterior aspect (Miyake-Apple view), and the eyes were processed for complete histopathology. At 4 weeks, the posterior capsule opacification score was 0.0 in the study group and 1.75 ± 0.5 (SD) in the control group (P=.005, paired t test). Ultrasound examination showed that 2 of the study IOLs had no contact between the posterior optic surface and the posterior capsule. Minimal proliferative cortical material was confined to the peripheral space between anterior and posterior rings of the study IOL haptics in localized areas at the equatorial region of the capsular bag. Anterior capsule opacification was absent in all eyes. The study IOL is a modification of a previous design, incorporating haptic perforations between the peripheral rings. By maintaining an open capsular bag and enhancing endocapsular inflow of aqueous, this modified design appears to prevent capsular bag opacification. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Capsule contraction syndrome with a microincision foldable hydrophilic acrylic intraocular lens: two case reports and review of the literature.

    PubMed

    Balestrazzi, Angelo; Malandrini, Alex; Martone, Gianluca; Marigliani, Davide; Caporossi, Tomaso; Tosi, Gian Marco

    2014-09-01

    Here we present 2 cases of capsule contraction syndrome (CCS). In both cases, a hydrophilic acrylic Akreos MI60 (Bausch and Lomb) intraocular lens (IOL) was implanted in the capsular bag through microincision cataract surgery, and the literature on the subject is reviewed. Since CCS has been described after the implantation of every IOL type, it is unlikely that the Akreos MI60 chemical and physical properties may cause CCS. When CCS occurs with IOLs composed of increasingly flexible materials that are inserted through incisions of decreasing size, a severe dislocation and deformation of IOL optics and haptics may develop. In both cases illustrated here, Nd:YAG laser anterior capsulotomy was highly effective. Hence, also based on the literature, which reports severe complications as a result of surgical intervention, it is suggested that Nd:YAG laser anterior capsulotomy be the first line of CCS treatment when the luxation of an IOL capsular bag is absent.

  12. Capsule Contraction Syndrome with a Microincision Foldable Hydrophilic Acrylic Intraocular Lens: Two Case Reports and Review of the Literature

    PubMed Central

    Balestrazzi, Angelo; Malandrini, Alex; Martone, Gianluca; Marigliani, Davide; Caporossi, Tomaso; Tosi, Gian Marco

    2014-01-01

    Here we present 2 cases of capsule contraction syndrome (CCS). In both cases, a hydrophilic acrylic Akreos MI60 (Bausch and Lomb) intraocular lens (IOL) was implanted in the capsular bag through microincision cataract surgery, and the literature on the subject is reviewed. Since CCS has been described after the implantation of every IOL type, it is unlikely that the Akreos MI60 chemical and physical properties may cause CCS. When CCS occurs with IOLs composed of increasingly flexible materials that are inserted through incisions of decreasing size, a severe dislocation and deformation of IOL optics and haptics may develop. In both cases illustrated here, Nd:YAG laser anterior capsulotomy was highly effective. Hence, also based on the literature, which reports severe complications as a result of surgical intervention, it is suggested that Nd:YAG laser anterior capsulotomy be the first line of CCS treatment when the luxation of an IOL capsular bag is absent. PMID:25473400

  13. Tasting edge effects

    NASA Astrophysics Data System (ADS)

    Bocquet, Lydéric

    2007-02-01

    We show that the baking of potato wedges constitutes a crunchy example of edge effects, which are usually demonstrated in electrostatics. A simple model of the diffusive transport of water vapor around the potato wedges shows that the water vapor flux diverges at the sharp edges in analogy with its electrostatic counterpart. This increased evaporation at the edges leads to the crispy taste of these parts of the potatoes.

  14. PERMEATION OF MULTIFUNCTIONAL ACRYLATES THROUGH SELECTED PROTECTIVE GLOVE MATERIALS

    EPA Science Inventory

    In support of the Premanufacture Notification (PMN) program of the Environmental Protection Agency's Office of Toxic Substances, the resistance of three glove materials to permeation by multifunctional acrylate compounds was evaluated through a program for the Office of Research ...

  15. Performance behavior of modified cellulosic fabrics using polyurethane acrylate copolymer.

    PubMed

    Zuber, Mohammad; Shah, Sayyed Asim Ali; Jamil, Tahir; Asghar, Muhammad Irfan

    2014-06-01

    The surface of the cellulosic fabrics was modified using self-prepared emulsions of polyurethane acrylate copolymers (PUACs). PUACs were prepared by varying the molecular weight of polycaprolactone diol (PCL). The PCL was reacted with isophorone diisocyanate (IPDI) and chain was extended with 2-hydroxy ethyl acrylate (HEA) to form vinyl terminated polyurethane (VTPU) preploymer. The VTPU was further co-polymerized through free radical polymerization with butyl acrylate in different proportions. The FT-IR spectra of monomers, prepolymers and copolymers assured the formation of proposed PUACs structure. The various concentrations of prepared PUACs were applied onto the different fabric samples using dip-padding techniques. The results revealed that the application of polyurethane butyl acrylate copolymer showed a pronounced effect on the tear strength and pilling resistance of the treated fabrics.

  16. PERMEATION OF MULTIFUNCTIONAL ACRYLATES THROUGH SELECTED PROTECTIVE GLOVE MATERIALS

    EPA Science Inventory

    In support of the Premanufacture Notification (PMN) program of the Environmental Protection Agency's Office of Toxic Substances, the resistance of three glove materials to permeation by multifunctional acrylate compounds was evaluated through a program for the Office of Research ...

  17. Use of acrylic sheet molds for elastomeric products

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Koerner, A. E.; Messineo, S. M.

    1970-01-01

    Molds constructed of acrylic sheet are more easily machined than metal, are transparent to ensure complete filling during injection, and have smooth surfaces free of contamination. Technique eliminates flashing on molded parts and mold release agents.

  18. Emulsion Polymerization of Butyl Acrylate: Spin Trapping and EPR Study

    NASA Technical Reports Server (NTRS)

    Kim, S.; Westmoreland, D.

    1994-01-01

    The propagating radical in the emulsion polymerization reaction of butyl acrylate was detected by Electron Paramagnetic Resonance spectroscopy using two spin trapping agents, 2-methyl-2nitrosopropane and alpha -N-tert-butylnitrone.

  19. Thermophysical properties of fluorinated acrylate homopolymers: Mixing and phase separation

    NASA Astrophysics Data System (ADS)

    Roussel, F.; Saidi, S.; Guittard, F.; Geribaldi, S.

    2002-06-01

    The thermophysical properties of fluorinated acrylate homopolymers are investigated by differential scanning calorimetry (DSC) and optical microscopy and discussed in terms of relative lengths of the fluorinated chain and the hydrocarbon spacer between the acrylate moiety and the fluorinated chain. These compounds exhibit an intrinsic microphase-separation (Isotropic+Isotropic morphology) occurring between the fluorinated chains and the acrylate polymer backbone. It is shown that the enthalpy of mixing is a function of the length of the lateral fluorocarbon chains. The thermophysical behaviour of these materials may be regarded as demixed systems exhibiting an Upper Critical Solution Temperature. The photopolymerization process of one of the monomer is studied by isothermal photocalorimetry. High acrylate double-bond conversion and fast curing rates were obtained thus demonstrating the promising use of these materials for coating and film processing applications using UV-curing techniques.

  20. Acrylamide/acrylic acid copolymers for cement fluid loss control

    SciTech Connect

    McKenzie, L.F.; McElfresh, P.M.

    1982-01-01

    Acrylamide/acrylic acid copolymers are considered as effective fluid loss control additives in a wide range of oil well cements. Unlike HEC based fluid loss aditives, these copolymers can be used with calcium chloride accelerator without significantly influencing fluid loss control. Another advantage of the copolymers is that the amount of fluid loss for a given concentration of polymer remains relatively constant over a wide range of temperatures. The use of acrylamide/acrylic acid copolymers has generally been restricted to wells below 60 degree C BHCT. Above that temperature chemical changes in the copolymer often lead to retardation of the cement. This paper presents data related to the use of acrylamide/acrylic acid copolymers as fluid loss control agents in oil well cementing. A comparison of these polymers with HEC based fluid loss control additives is made. In addition, data related to the cause of acrylamide/acrylic acid copolymer retarding effects is presented. 4 refs.

  1. Emulsion Polymerization of Butyl Acrylate: Spin Trapping and EPR Study

    NASA Technical Reports Server (NTRS)

    Kim, S.; Westmoreland, D.

    1994-01-01

    The propagating radical in the emulsion polymerization reaction of butyl acrylate was detected by Electron Paramagnetic Resonance spectroscopy using two spin trapping agents, 2-methyl-2nitrosopropane and alpha -N-tert-butylnitrone.

  2. Fabrication of interim acrylic resin removable partial dentures with clasps.

    PubMed

    Reitz, P V; Weiner, M G

    1978-12-01

    An orderly sequence of steps for construction of an interim acrylic resin partial denture has been presented. The technique allows the dentist to fabricate an effective restoration that has a definite path of insertion and removal that can be placed in the patient's mouth with little time spent on adjustment and correction. This technique may be used with heat- or cold-curing acrylic resin.

  3. Modification of hydrophobic acrylic intraocular lens with poly(ethylene glycol) by atmospheric pressure glow discharge: A facile approach

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Wang, Yao; Huang, Xiao-Dan; Xu, Zhi-Kang; Yao, Ke

    2010-10-01

    To improve the anterior surface biocompatibility of hydrophobic acrylic intraocular lens (IOL) in a convenient and continuous way, poly(ethylene glycol)s (PEGs) were immobilized by atmospheric pressure glow discharge (APGD) treatment using argon as the discharge gas. The hydrophilicity and chemical changes on the IOL surface were characterized by static water contact angle and X-ray photoelectron spectroscopy to confirm the covalent binding of PEG. The morphology of the IOL surface was observed under field emission scanning electron microscopy and atomic force microscopy. The surface biocompatibility was evaluated by adhesion experiments with platelets, macrophages, and lens epithelial cells (LECs) in vitro. The results revealed that the anterior surface of the PEG-grafted IOL displayed significantly and permanently improved hydrophilicity. Cell repellency was observed, especially in the PEG-modified IOL group, which resisted the attachment of platelets, macrophages and LECs. Moreover, the spread and growth of cells were suppressed, which may be attributed to the steric stabilization force and chain mobility effect of the modified PEG. All of these results indicated that hydrophobic acrylic IOLs can be hydrophilic modified by PEG through APGD treatment in a convenient and continuous manner which will provide advantages for further industrial applications.

  4. Supersonic Leading Edge Receptivity

    NASA Technical Reports Server (NTRS)

    Maslov, Anatoly A.

    1998-01-01

    This paper describes experimental studies of leading edge boundary layer receptivity for imposed stream disturbances. Studies were conducted in the supersonic T-325 facility at ITAM and include data for both sharp and blunt leading edges. The data are in agreement with existing theory and should provide guidance for the development of more complete theories and numerical computations of this phenomena.

  5. The Edge, Fall 1999.

    ERIC Educational Resources Information Center

    Edge, 1999

    1999-01-01

    "The Edge" is a Canadian publication for youth. The mandate of the Edge is to support and celebrate all career journeys embraced by youth. This issue contains career profile articles covering three jobs: crane operator, indoor climbing instructor, and product certification tester. Career trends and the state of today's workplace are also…

  6. Poly(meth)acrylates obtained by cascade reaction.

    PubMed

    Popescu, Dragos; Keul, Helmut; Moeller, Martin

    2011-04-04

    Preparation, purification, and stabilization of functional (meth)acrylates with a high dipole moment are complex, laborious, and expensive processes. In order to avoid purification and stabilization of the highly reactive functional monomers, a concept of cascade reactions was developed comprising enzymatic monomer synthesis and radical polymerization. Transacylation of methyl acrylate (MA) and methyl methacrylate (MMA) with different functional alcohols, diols, and triols (1,2,6-hexanetriol and glycerol) in the presence of Novozyme 435 led to functional (meth)acrylates. After the removal of the enzyme by means of filtration, removal of excess (meth)acrylate and/or addition of a new monomer, e.g., 2-hydroxyethyl (meth)acrylate the (co)polymerization via free radical (FRP) or nitroxide mediated radical polymerization (NMP) resulted in poly[(meth)acrylate]s with predefined functionalities. Hydrophilic, hydrophobic as well as ionic repeating units were assembled within the copolymer. The transacylation of MA and MMA with diols and triols carried out under mild conditions is an easy and rapid process and is suitable for the preparation of sensitive monomers.

  7. Stabilizing effects of estertins mercaptide (methyl acrylate) for PVC degradation

    NASA Astrophysics Data System (ADS)

    Zhang, S. H.; Liu, T. M.; Li, J. L.; Wang, C. R.; Li, C.; Wang, Z. Q.

    2016-07-01

    The thermal and UV light (ultraviolet light) stability of PVC films with estertins mercaptide (methyl acrylate), methyltins mercaptide and the compound consisted of estertins mercaptide (methyl acrylate) and hydrotalcite (2:2.5) were investigated by ageing in a circulation oven at 190 °C and irradiating with 72W UV light for 96h, respectively, and then the yellowness and transmission rate were tested by Color Quest XE. Hydrotalcite was proved to have good synergies with estertins mercaptide (methyl acrylate) on improving the thermal stability and UV light stability. The retarding effects of the heat stabilizers to PVC degradation were tested by TGA from 50°C to 600°C. The results show that temperature of HCl evolution from PVC film was improved obviously by compounding with estertins mercaptide(methyl acrylate) and hydrotalcite and estertins mercaptide(methyl acrylate) was found to have a better long term stability. Sn4+ consistence of water and seawater in which films before and after UV light irradiation were soaked for 60 days was analyzed by ICP; the results indicate that the Sn4+ consistence from the films with estertins mercaptide(methyl acrylate) as thermal stabilizer was lower than that from the film with methyltins mercaptide. The crosslink moderately by UV irradiation for PVC films can hold back the dissolution of organotin heat stabilizers from PVC products into water and seawater.

  8. Advances in acrylic-alkyd hybrid synthesis and characterization

    NASA Astrophysics Data System (ADS)

    Dziczkowski, Jamie

    2008-10-01

    In situ graft acrylic-alkyd hybrid resins were formed by polymerizing acrylic and acrylic-mixed monomers in the presence of alkyds by introduction of a free radical initiator to promote graft formation. Two-dimensional NMR, specifically gradient heteronuclear multiple quantum coherence (gHMQC), was used to clarify specific graft sites of the hybrid materials. Both individual and mixed-monomer systems were produced to determine any individual monomer preferences and to model current acrylic-alkyd systems. Different classes of initiators were used to determine any initiator effects on graft location. The 2D-NMR results confirm grafting at doubly allylic hydrogens located on the fatty acid chains and the polyol segment of the alkyd backbone. The gHMQC spectra show no evidence of grafting across double bonds on either pendant fatty acid groups or THPA unsaturation sites for any of the monomer or mixed monomer systems. It was also determined that choice of initiator has no effect on graft location. In addition, a design of experiments using response surface methodology was utilized to obtain a better understanding of this commercially available class of materials and relate both the chemical and physical properties to one another. A Box-Behnkin design was used, varying the oil length of the alkyd phase, the degree of unsaturation in the polyester backbone, and acrylic to alkyd ratio. Acrylic-alkyd hybrid resins were reduced with an amine/water mixture. Hydrolytic stability was tested and viscoelastic properties were obtained to determine crosslink density. Cured films were prepared and basic coatings properties were evaluated. It was found that the oil length of the alkyd is the most dominant factor for final coatings properties of the resins. Acrylic to alkyd ratio mainly influences the resin properties such as acid number, average molecular weight, and hydrolytic stability. The degree of unsaturation in the alkyd backbone has minimal effects on resin and film

  9. Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses.

    PubMed

    Vasavada, Abhay R; Raj, Shetal M; Shah, Alpesh; Shah, Gauri; Vasavada, Viraj; Vasavada, Vaishali

    2011-06-01

    To compare posterior capsule opacification (PCO) 3 years postoperatively in contralateral eyes with a single-piece hydrophobic acrylic and 1 of 2 single-piece hydrophilic acrylic intraocular lenses (IOLs) with different configurations. Iladevi Cataract and IOL Research Institute, Ahmedabad, India. Prospective randomized clinical trial. A hydrophobic Acrysof (hydrophobic group) or a hydrophilic C-flex (hydrophilic group C) or Akreos Adapt IOL (hydrophilic group A) was randomized for implantation in the fellow eye or vice versa of each patient. The Evaluation of Posterior Capsule Opacification (EPCO) area, EPCO score, and neodymium:YAG (Nd:YAG) capsulotomy rates were compared using digital photographs. The study enrolled 68 patients. Although there was no significant difference at 1 month, the median EPCO score was statistically significantly lower in the hydrophobic group than in hydrophilic group C (P = .00) and hydrophilic group A (P = .000) at 3 years. There were no significant differences in the median EPCO area at 1 month; however, the area was statistically significantly less in the hydrophobic group than in hydrophilic group C and hydrophilic group A at 3 years (both P = .000). Four (12.9%) of 31 eyes in hydrophilic group C and 5 (16%) of 31 eyes in hydrophilic group A required an Nd:YAG capsulotomy; no eye in the hydrophobic group required a capsulotomy (P = .04 and P = .02, respectively). Posterior capsule opacification was significantly less with the Acrysof hydrophobic acrylic IOL at 3 years. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Anterior cruciate ligament repair - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100230.htm Anterior cruciate ligament repair - Series—Normal anatomy To use the sharing ... to slide 5 out of 5 Overview The anterior cruciate ligament (ACL) is a ligament in the center of ...

  11. Acrylated chitosan for mucoadhesive drug delivery systems.

    PubMed

    Shitrit, Yulia; Bianco-Peled, Havazelet

    2017-01-30

    A new mucoadhesive polymer was synthesized by conjugating chitosan to poly(ethylene glycol)diacrylate (PEGDA) via the Michael type reaction. The product was characterized using NMR. Higher PEGDA grafting efficacy was observed with low molecular weight PEGDA (0.7kDa), compared to long 10kDa PEGDA. The acrylation percentage was calculated based on the reaction of ninhydrin with chitosan, and supported the qualitative NMR findings. The adhesive properties were studied by tensile test and rotating system involving detachment of polymer tablets from a fresh intestine sample. Chitosan modified with high molecular weight PEGDA presented improvement in mucoadhesive properties compared to both non-modified and thiolated chitosan. On the molecular level, rheology measurements of polymer/mucin mixtures provided additional evidence of strong interaction between modified chitosan and mucin glycoproteins. This new polymer shows promise as a useful polymeric carrier matrix for delivery systems, which could provide prolonged residence time of the vehicle on the mucosa surface. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Analysis of emulsion stability in acrylic dispersions

    NASA Astrophysics Data System (ADS)

    Ahuja, Suresh

    2012-02-01

    Emulsions either micro or nano permit transport or solubilization of hydrophobic substances within a water-based phase. Different methods have been introduced at laboratory and industrial scales: mechanical stirring, high-pressure homogenization, or ultrasonics. In digital imaging, toners may be formed by aggregating a colorant with a latex polymer formed by batch or semi-continuous emulsion polymerization. Latex emulsions are prepared by making a monomer emulsion with monomer like Beta-carboxy ethyl acrylate (β-CEA) and stirring at high speed with an anionic surfactant like branched sodium dodecyl benzene sulfonates , aqueous solution until an emulsion is formed. Initiator for emulsion polymerization is 2-2'- azobis isobutyramide dehydrate with chain transfer agent are used to make the latex. If the latex emulsion is unstable, the resulting latexes produce a toner with larger particle size, broader particle size distribution with relatively higher latex sedimentation, and broader molecular weight distribution. Oswald ripening and coalescence cause droplet size to increase and can result in destabilization of emulsions. Shear thinning and elasticity of emulsions are applied to determine emulsion stability.

  13. Anterior tarsal tunnel syndrome.

    PubMed

    DiDomenico, Lawrence A; Masternick, Eric B

    2006-07-01

    Compression of the deep peroneal nerve is commonly referred to as anterior tarsal tunnel syndrome. Although rare, this syndrome remains poorly diagnosed. The syndrome is characterized by pain, weakness, and sensory changes of the foot and ankle. Non-operative measures should be attempted to reduce or remove the external compression along the anterior aspect of the foot and ankle. Other options include shoe modifications, cortisone injections,and physical therapy. If conservative management fails to relieve the symptoms, surgical decompression of the entrapped nerve can be performed. The deep peroneal nerve is released from compressive forces in the entrapment site. This can be performed at the more proximal level at the extensor retinaculum or more distally at the level of the tarsal metatarsal site.

  14. [Anterior pseudodiverticulum after laryngectomy].

    PubMed

    Pitzer, G; Oursin, C; Wolfensberger, M

    1998-01-01

    An anterior neopharyngeal pseudodiverticulum is a mucosal pouch located between the tongue and hypopharynx due to an epiglottis-like posterior tissue band that forms after total laryngectomy. This condition has rarely been mentioned in literature. Incidence, symptoms, treatment, and possible etiologic factors were examined. Twenty post-laryngectomy patients were questioned about swallowing disorders and were examined clinically and by barium swallow. Eleven patients were found to have a pseudodiverticulum, of which 9 patients suffered from dysphagia. We found no correlation between the formation of a pseudodiverticulum and radiotherapy or post-laryngectomy complications. All symptomatic patients were treated by dissecting the posterior tissue band endoscopically with a CO2-laser, bringing complete relief of symptoms in 8 of 9 patients. Our study showed that the anterior pseudodiverticulum can be a frequent cause of dysphagia after laryngectomy. It can easily be diagnosed clinically and radiologically. Endoscopic treatment with a CO2-laser is simple and effective.

  15. Ultrasound biomicroscopic analysis of iris-fixed acrylic intraocular lens in the absence of capsule support.

    PubMed

    Avitabile, Teresio; Bonfiglio, Vincenza; Castiglione, Francesco; Gagliano, Caterina; Reibaldi, Michele; Pulvirenti, Manuela; Reibaldi, Alfredo

    2012-12-01

    The aim of the study was to investigate postoperative complications and to determine with ultrasound biomicroscopy (UBM) the position of a foldable acrylic intraocular lens (IOL) implanted with a surgical technique of iris suturing in eyes without capsule support. Six eyes with iris-sutured IOLs were examined postoperatively with UBM. The examination included the position of haptics and their relationship to the surrounding structures. Other parameters studied were central anterior chamber depth, IOL iris contact and pigment dispersion. The position of all 12 haptics was determined. All haptics were in touch with the iris. Pigment dispersion was seen in two cases. The anterior chamber depth of the sutured eyes was normal. There was neither cystoid macular edema nor chronic uveitis postoperatively. In conclusion, in most cases surgical placement of iris-fixed lenses is a blind procedure and UBM could be an appropriate method to determine the position of IOL haptics postoperatively and to demonstrate that this surgical technique is reproducible, safe, and effective with the limitation of the difficulty of iris suturing IOL.

  16. Esthetic rehabilitation of anterior discolored teeth with lithium disilicate all-ceramic restorations.

    PubMed

    Prevedello, Gustavo Costa; Vieira, Marcelo; Furuse, Adilson Yoshio; Correr, Gisele Maria; Gonzaga, Carla Castiglia

    2012-01-01

    The esthetic treatment of darkened anterior teeth represents a great challenge to dentists, because dental materials ideally should match the natural teeth. The optical behavior of the final restoration is determined by the color of the underlying tooth structure, the color of the luting agent, and the thickness and opacity of the ceramic material used. This article reports a case in which veneers and full crowns made of heat-pressed, lithium disilicate glass-ceramic were used for the esthetic rehabilitation of anterior discolored teeth. The patient was referred for treatment with defective anterior composite resin restorations, provisional acrylic resin crowns, darkening of the gingival margins, and uneven gingival contours. The multidisciplinary treatment plan included dental bleaching, periodontal plastic surgery to create gingival symmetry, and indirect all-ceramic restorations using high-opacity lithium disilicate glass-ceramic ingots. The treatment was successful and an excellent esthetic result was achieved.

  17. The digital step edge

    NASA Technical Reports Server (NTRS)

    Haralick, R. M.

    1982-01-01

    The facet model was used to accomplish step edge detection. The essence of the facet model is that any analysis made on the basis of the pixel values in some neighborhood has its final authoritative interpretation relative to the underlying grey tone intensity surface of which the neighborhood pixel values are observed noisy samples. Pixels which are part of regions have simple grey tone intensity surfaces over their areas. Pixels which have an edge in them have complex grey tone intensity surfaces over their areas. Specially, an edge moves through a pixel only if there is some point in the pixel's area having a zero crossing of the second directional derivative taken in the direction of a non-zero gradient at the pixel's center. To determine whether or not a pixel should be marked as a step edge pixel, its underlying grey tone intensity surface was estimated on the basis of the pixels in its neighborhood.

  18. Edge wave visualization

    NASA Technical Reports Server (NTRS)

    Dominek, Allen K.; Nguyen, Truong X.

    1991-01-01

    Scattering mechanisms that involve edge waves are addressed. The behavior of edge waves and their interaction with flat, perfectly conducting plates are depicted in the time domain through a visualization of surface currents that flow on the surface, as an incident Gaussian pulse of energy washes over the surface. Viewing these surface currents allows a very clear physical interpretation and appreciation of the scattering process.

  19. Large deformation micromechanics of particle filled acrylics at elevated temperatures

    NASA Astrophysics Data System (ADS)

    Gunel, Eray Mustafa

    The main aim of this study is to investigate stress whitening and associated micro-deformation mechanism in thermoformed particle filled acrylic sheets. For stress whitening quantification, a new index was developed based on image histograms in logarithmic scale of gray level. Stress whitening levels in thermoformed acrylic composites was observed to increase with increasing deformation limit, decreasing forming rate and increasing forming temperatures below glass transition. Decrease in stress whitening levels above glass transition with increasing forming temperature was attributed to change in micro-deformation behavior. Surface deformation feature investigated with scanning electron microscopy showed that source of stress whitening in thermoformed samples was a combination of particle failure and particle disintegration depending on forming rate and temperature. Stress whitening level was strongly correlated to intensity of micro-deformation features. On the other hand, thermoformed neat acrylics displayed no surface discoloration which was attributed to absence of micro-void formation on the surface of neat acrylics. Experimental damage measures (degradation in initial, secant, unloading modulus and strain energy density) have been inadequate in describing damage evolution in successive thermoforming applications on the same sample at different levels of deformation. An improved version of dual-mechanism viscoplastic material model was proposed to predict thermomechanical behavior of neat acrylics under non-isothermal conditions. Simulation results and experimental results were in good agreement and failure of neat acrylics under non-isothermal conditions ar low forming temperatures were succesfully predicted based on entropic damage model. Particle and interphase failure observed in acrylic composites was studied in a multi-particle unit cell model with different volume fractions. Damage evolution due to particle failure and interphase failure was simulated

  20. A direct technique for fabricating esthetic anterior fixed provisional restorations using polycarbonate veneers.

    PubMed

    Bidra, Avinash S; Manzotti, Anna

    2012-06-01

    Fabrication of esthetic interim restorations by a chairside technique often challenges the clinician with regard to the required time and skills, as well as meeting the expectations of the patient. Autopolymerizing polymethyl methacrylate resin has been reported to be the most popular material for fabricating provisional restorations. However, this material does not routinely yield esthetic provisional restorations via a chairside technique. This article describes a simple technique to overcome some of the disadvantages of this material by using prefabricated polycarbonate facings backed with autopolymerizing acrylic resin. This technique can be used chairside for fabricating esthetic anterior interim restorations, utilizing the beneficial properties of both materials. It exploits the manufactured smooth-surface finish, superior esthetics, color stability, and durability of polycarbonate facings, as well as the marginal adaptation, strength, and low cost of autopolymerizing acrylic resin.

  1. Acrylic Resin Cytotoxicity for Denture Base--Literature Review.

    PubMed

    Goiato, Marcelo C; Freitas, Emily; dos Santos, Daniela; de Medeiros, Rodrigo; Sonego, Mariana

    2015-01-01

    Acrylic resin is a widely used material in clinical practice, and a satisfactory biocompatibility is essential. When the resin polymerization reaction is incomplete, residual monomers are released into the oral cavity. The aim of this study was to evaluate, through a literature review, the cytotoxicity caused by the denture base acrylic resin used, and its components. The selection of published studies was performed on the Pubmed database from January 2008 to July 2013. The keywords used were: "cytotoxicity and acrylic resins", "cytotoxicity and denture base resins" and "cytotoxicity and oral prosthesis". Inclusion criteria were: in vitro studies and literature reviews published in English that evaluated the acrylic resin cytotoxicity for denture base and its components. Studies with no reference to the search strategy were excluded. A total of 182 articles were found. Among these, only 13 were included for writing this review. The MTT test is the most common test used to evaluate acrylic resin cytotoxicity. Auto-polymerized resin is more cytotoxic than heat-polymerized resin because of its higher quantity of residual monomers which cause cell and tissue changes in the oral mucosa. However, more studies are necessary for the development of biocompatible materials.

  2. Impact Delamination and Fracture in Aluminum/Acrylic Sandwich Plates

    NASA Technical Reports Server (NTRS)

    Liaw, Benjamin; Zeichner, Glenn; Liu, Yanxiong; Bowles, Kenneth J. (Technical Monitor)

    2000-01-01

    Impact-induced delamination and fracture in 6061-T6 aluminum/cast acrylic sandwich plates adhered by epoxy were generated in an instrumented drop-weight impact machine. Although only a small dent was produced on the aluminum side when a hemispherical penetrator tup was dropped onto it from a couple of inches, a large ring of delamination at the interface was observed. The delamination damage was often accompanied by severe shattering in the acrylic substratum. Damage patterns in the acrylic layer include radial and ring cracks and, together with delamination at the interface, may cause peeling-off of acrylic material from the sandwich plate. Theory of stress-wave propagation can be used to explain these damage patterns. The impact tests were conducted at various temperatures. The results also show clearly that temperature effect is very important in impact damage. For pure cast acrylic nil-ductile transition (NDT) occurs between 185-195 F. Excessive impact energy was dissipated into fracture energy when tested at temperature below this range or through plastic deformation when tested at temperature above the NDT temperature. Results from this study will be used as baseline data for studying fiber-metal laminates, such as GLARE and ARALL for advanced aeronautical and astronautical applications.

  3. Annulus tension of the prolapsed mitral valve corrected by edge-to-edge repair.

    PubMed

    Bhattacharya, Shamik; He, Zhaoming

    2012-02-02

    Mitral valve (MV) performance after edge-to-edge repair (ETER) without ring annuloplasty is suboptimal. ETER efficacy needs to be evaluated from annulus tension (AT) of a prolapsed MV corrected by ETER to understand annular dilatation. Ten porcine MVs were harvested and mounted on a MV closure test rig. The MV annulus tissue rested on top of a saddle-shaped plastic ring on which the annulus could slide freely. The annulus was held by strings in the periphery during MV closure under a hydrostatic trans-mitral pressure. String tensions were measured and further divided by string spacing to obtain AT. The MVs were then prolapsed by shifting split papillary muscles to simulate mono-leaflet prolapse due to elongation of chords, which insert into a single leaflet. Last, MV prolapse was corrected by ETER applied in the central leaflet region and AT was measured. AT in both anterior and posterior leaflet prolapse corrected by ETER was less than that of normal MVs. AT in the anterior leaflet prolapse corrected by ETER was less than that in the posterior leaflet prolapse corrected by ETER. ETER does not restore the normal AT and therefore leads potential of annular dilatation. The anterior leaflet prolapse has a greater potential of annular dilatation than the posterior leaflet prolapse after ETER. Annuloplasty is recommended to maintain long-term ETER efficacy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Relationship Between the Lateral Center-Edge Angle and 3-Dimensional Acetabular Coverage.

    PubMed

    Wylie, James D; Kapron, Ashley L; Peters, Christopher L; Aoki, Stephen K; Maak, Travis G

    2017-04-01

    The lateral center-edge angle (LCEA) is an important measurement in understanding acetabular morphology and has had multiple interpretations. Misunderstanding of the LCEA and its relationship with acetabular 3-dimensional (3D) morphology may result in misdiagnosis and poor outcomes. To determine the discrepancy between bone-edge and sourcil-edge LCEA measurements on anteroposterior (AP) radiographs and to determine the 3D anatomic location of the sourcil-edge and bone-edge LCEA measurements. Cohort study (diagnosis); Level of evidence, 2. The LCEA was measured on radiographs to both the sourcil-edge and bone-edge on AP images of 60 symptomatic hips. On computed tomography (CT), coronal slices producing an LCEA matching the magnitude of each AP LCEA were identified. These coronal slices were mapped to a sagittal image of the acetabulum, which was divided into a standard clockface (3 = anterior, 12 = superior). We identified clockface locations corresponding to the AP sourcil-edge and bone-edge LCEA measurements. Paired t tests identified differences in magnitude and location of the bone and sourcil LCEAs. Limits of agreement were calculated for the differences between measures. Intraclass correlation coefficients (ICCs) assessed inter- and intraobserver repeatability. On the AP radiographs, the bone-edge LCEA was a mean 4.7° (95% CI, -4.0° to 13.3°) greater than the sourcil-edge LCEA (P < .001). On CT, the sagittal clockface location of the sourcil-edge LCEA was more anterior compared with the sagittal clockface location of the maximum bone-edge LCEA (1:03 ± 0:42 vs 12:06 ± 0:30, respectively; P < .001). In hips with a difference >5° between sourcil-edge and bone-edge measurements, the coronal CT slice corresponding to the sourcil-edge LCEA was significantly more anterior (1:26 ± 0:35) than the CT slice corresponding to the bone-edge LCEA (11:46 ± 0:29; P < .001). This significant difference was similar in location but less pronounced in hips with a

  5. Anterior knee pain.

    PubMed

    LLopis, Eva; Padrón, Mario

    2007-04-01

    Anterior knee pain is a common complain in all ages athletes. It may be caused by a large variety of injuries. There is a continuum of diagnoses and most of the disorders are closely related. Repeated minor trauma and overuse play an important role for the development of lesions in Hoffa's pad, extensor mechanism, lateral and medial restrain structures or cartilage surface, however usually an increase or change of activity is referred. Although the direct relation of cartilage lesions, especially chondral, and pain is a subject of debate these lesions may be responsible of early osteoarthrosis and can determine athlete's prognosis. The anatomy and biomechanics of patellofemoral joint is complex and symptoms are often unspecific. Transient patellar dislocation has MR distinct features that provide evidence of prior dislocation and rules our complication. However, anterior knee pain more often is related to overuse and repeated minor trauma. Patella and quadriceps tendon have been also implicated in anterior knee pain, as well as lateral or medial restraint structures and Hoffa's pad. US and MR are excellent tools for the diagnosis of superficial tendons, the advantage of MR is that permits to rule out other sources of intraarticular derangements. Due to the complex anatomy and biomechanic of patellofemoral joint maltracking is not fully understood; plain films and CT allow the study of malalignment, new CT and MR kinematic studies have promising results but further studies are needed. Our purpose here is to describe how imaging techniques can be helpful in precisely defining the origin of the patient's complaint and thus improve understanding and management of these injuries.

  6. The Edge supersonic transport

    NASA Technical Reports Server (NTRS)

    Agosta, Roxana; Bilbija, Dushan; Deutsch, Marc; Gallant, David; Rose, Don; Shreve, Gene; Smario, David; Suffredini, Brian

    1992-01-01

    As intercontinental business and tourism volumes continue their rapid expansion, the need to reduce travel times becomes increasingly acute. The Edge Supersonic Transport Aircraft is designed to meet this demand by the year 2015. With a maximum range of 5750 nm, a payload of 294 passengers and a cruising speed of M = 2.4, The Edge will cut current international flight durations in half, while maintaining competitive first class, business class, and economy class comfort levels. Moreover, this transport will render a minimal impact upon the environment, and will meet all Federal Aviation Administration Part 36, Stage III noise requirements. The cornerstone of The Edge's superior flight performance is its aerodynamically efficient, dual-configuration design incorporating variable-geometry wingtips. This arrangement combines the benefits of a high aspect ratio wing at takeoff and low cruising speeds with the high performance of an arrow-wing in supersonic cruise. And while the structural weight concerns relating to swinging wingtips are substantial, The Edge looks to ever-advancing material technologies to further increase its viability. Heeding well the lessons of the past, The Edge design holds economic feasibility as its primary focus. Therefore, in addition to its inherently superior aerodynamic performance, The Edge uses a lightweight, largely windowless configuration, relying on a synthetic vision system for outside viewing by both pilot and passengers. Additionally, a fly-by-light flight control system is incorporated to address aircraft supersonic cruise instability. The Edge will be produced at an estimated volume of 400 aircraft and will be offered to airlines in 2015 at $167 million per transport (1992 dollars).

  7. Allergic contact stomatitis caused by acrylic monomer in a denture.

    PubMed

    Koutis, D; Freeman, S

    2001-08-01

    A 71-year-old edentulous man developed a severely painful red mouth at sites of contact with a new denture. Patch testing showed allergy to samples of the denture material and to 2-hydroxyethyl methacrylate. Patch testing to methyl methacrylate was negative. Prolonged boiling of the denture resulted in reversal of his symptoms and samples of this fully cured denture material produced negative patch tests. While allergy to acrylates is a rare cause of stomatitis, this possibility must be considered in patients presenting with oral symptoms. Material safety data sheets are unreliable in providing information regarding the type of acrylate present in the material. Hence, patch testing should be performed with a battery of acrylate allergens as well as with small samples of the denture material.

  8. Nucleophilic Addition of Reactive Dyes on Amidoximated Acrylic Fabrics

    PubMed Central

    El-Shishtawy, Reda M.; El-Zawahry, Manal M.; Abdelghaffar, Fatma; Ahmed, Nahed S. E.

    2014-01-01

    Seven reactive dyes judiciously selected based on chemical structures and fixation mechanisms were applied at 2% owf of shade on amidoximated acrylic fabrics. Amidoximated acrylic fabric has been obtained by a viable amidoximation process. The dyeability of these fabrics was evaluated with respect to the dye exhaustion, fixation, and colour strength under different conditions of temperature and dyeing time. Nucleophilic addition type reactive dyes show higher colour data compared to nucleophilic substitution ones. FTIR studies further implicate the binding of reactive dyes on these fabrics. A tentative mechanism is proposed to rationalize the high fixation yield obtained using nucleophilic addition type reactive dyes. Also, the levelling and fastness properties were evaluated for all dyes used. Excellent to good fastness and levelling properties were obtained for all samples irrespective of the dye used. The result of investigation offers a new method for a viable reactive dyeing of amidoximated acrylic fabrics. PMID:25258720

  9. Biocatalytic functionalization of hydroxyalkyl acrylates and phenoxyethanol via phosphorylation.

    PubMed

    Tasnádi, Gábor; Hall, Mélanie; Baldenius, Kai; Ditrich, Klaus; Faber, Kurt

    2016-09-10

    The enzymatic phosphorylation of phenoxyethanol, 2-hydroxyethyl acrylate and 4-hydroxybutyl acrylate catalyzed by acid phosphatases PhoN-Sf and PiACP at the expense of inorganic di-, tri-, hexameta- or polyphosphate was applied to the preparative-scale synthesis of phosphorylated compounds. The reaction conditions were optimized with respect to enzyme immobilization, substrate concentration, pH and type of phosphate donor. The mild reaction conditions prevented undesired polymerization and hydrolysis of the acrylate ester moiety. Application of a continuous flow system allowed facile scale-up and mono-phosphates were obtained in up to 26% isolated yield with space-time yields of 0.89kgL(-1)h(-1).

  10. Tear Film Dynamics and Cooling of the Anterior Eye

    NASA Astrophysics Data System (ADS)

    Li, Longfei; Braun, Richard

    2011-11-01

    A model for cooling of the human tear film is formulated by incorporating the heat transfer from the interior of the eye. A single PDE that governs the thickness of the film is derived from lubrication theory; the nonlinear partial differential equation is to be solved along the edge of a model rectangular domain for the anterior eye that includes the cornea (thin and thick substrate cases are treated separately). Optimal parameters to reproduce observed temperature decreases are found.

  11. Effect of Cigarette Smoke on Acrylic Resin Teeth

    PubMed Central

    Patil, Seema S.; M.R., Dhakshaini; Gujjari, Anil Kumar

    2013-01-01

    Background: The discolouration of artificial teeth, which hampers aesthetics, is one of the negative effects of cigarette smoking. Therefore, the effect of cigarette smoke on the colour stability of commercially available acrylic resin teeth needs to be evaluated for clinical success and to ascertain as to which brand has superior properties. Material and Methods: Three commercially available acrylic teeth were evaluated, after division into Group A (Premadent), Group B (Astra), and Group C (Sanyo- Dent). Selected brands were subdivided as study group and control group. Each set of acrylic resin teeth were stored in artificial saliva at 37±1°C for 24 hours. After 24 hours of immersion, the colour measurement of each tooth (T0) was performed. Second colour measurements were done after 21 days (T21) of exposure to cigarette smoke for study group and after immersion in artificial saliva for control group. All data was statistically analyzed by using Repeated Measures ANOVA and Two-way ANOVA (p<0.05). Results: Group A showed least total colour change on exposure to cigarette smoke, followed by Group B and Group C had the highest total colour change. In control group, after immersion in artificial saliva, a slight increase in total colour change was observed for all groups, which was clinically acceptable. Conclusion: Group A (crosslinked acrylic resin teeth) was more colour stable and more resistant to the discolouration which was caused by cigarette smoke, followed by Group B (crosslinked acrylic resin teeth). Group C (Non-crosslinked acrylic resin teeth) was least colour stable and most susceptible to discolouration which was caused by cigarette smoke. PMID:24179942

  12. Colour Stability of Heat and Cold Cure Acrylic Resins

    PubMed Central

    Ganesh, P R; Reddy, Madan Mohan; Ebenezar, A.V. Rajesh; Sivakumar, G

    2015-01-01

    Introduction: To evaluate the colour stability of heat and cold cure acrylic resins under simulated oral conditions with different colorants. Materials and Methods: Three different brands of heat cure acrylic resin and two rapid cure auto polymerizing acrylic resin of commercial products such as Trevelon Heat Cure (THC), DPI Heat cure (DHC), Pyrax Heat Cure (PHC), DPI Cold cure (DCC) and Acralyn-R-Cold cure (ACC) have been evaluated for discoloration and colour variation on subjecting it to three different, commonly employed food colorants such as Erythrosine, Tartarizine and Sunset yellow. In order to simulate the oral condition the food colorants were diluted with artificial saliva to the samples taken up for the study. These were further kept in an incubator at 37°C ± 1°C. The UV-visible spectrophotometer has been utilized to evaluate the study on the basis of CIE L* a* b* system. The prepared samples for standard evaluation have been grouped as control group, which has been tested with a white as standard, which is applicable for testing the colour variants. Results: The least colour changes was found to be with Sunset Yellow showing AE* value of 3.55 with heat cure acrylic resin branded as PHC material and the highest colour absorption with Tartarizine showing AE* value of 12.43 in rapid cure autopolymerzing acrylic resin material branded as ACC material. Conclusion: ACC which is a self cure acrylic resin shows a higher colour variation to the tartarizine food coloration. There were not much of discoloration values shown on the denture base resins as the food colorants are of organic azodyes. PMID:25738078

  13. Adaptable edge quality metric

    NASA Astrophysics Data System (ADS)

    Strickland, Robin N.; Chang, Dunkai K.

    1990-09-01

    A new quality metric for evaluating edges detected by digital image processing algorithms is presented. The metric is a weighted sum of measures of edge continuity smoothness thinness localization detection and noisiness. Through a training process we can design weights which optimize the metric for different users and applications. We have used the metric to compare the results of ten edge detectors when applied to edges degraded by varying degrees of blur and varying degrees and types of noise. As expected the more optimum Difference-of-Gaussians (DOG) and Haralick methods outperform the simpler gradient detectors. At high signal-to-noise (SNR) ratios Haralick''s method is the best choice although it exhibits a sudden drop in performance at lower SNRs. The DOG filter''s performance degrades almost linearly with SNR and maintains a reasonably high level at lower SNRs. The same relative performances are observed as blur is varied. For most of the detectors tested performance drops with increasing noise correlation. Noise correlated in the same direction as the edge is the most destructive of the noise types tested.

  14. Anterior vitrectomy for shallow anterior chamber after cataract extraction.

    PubMed

    Dottan, S; Levartovsky, S; Oliver, M

    1982-06-01

    Pars plana anterior vitrectomy was performed in 9 patients with shallow anterior chamber after cataract extraction. Five patients had choroidal and/or ciliary body effusion (CCBE), and 4 had aphakic pupillary block (APB). Vitrectomy was performed only after medical treatment failed to restore a normal anterior chamber depth. In all patients the anterior chamber restored during surgery and remained so thereafter, although in patients with CCBE, the fundal pathology subsided days or even months later. The only surgical complication was a longstanding cystoid macular oedema in one patient. Pars plana vitrectomy would appear to have advantages over other surgical techniques, in similar circumstances.

  15. Uveitis (acute anterior).

    PubMed

    Islam, Niaz; Pavesio, Carlos

    2010-04-08

    Anterior uveitis is rare, with an annual incidence of 12/100,000 population, although it is more common in Finland (annual incidence of 23/100,000), probably because of genetic factors, such as high frequency of HLA-B27 in the population. It is often self-limiting, but can, in some cases, lead to complications such as posterior synechiae, cataract, glaucoma, and chronic uveitis. We conducted a systematic review and aimed to answer the following clinical question: What are the effects of anti-inflammatory eye drops on acute anterior uveitis? We searched: Medline, Embase, The Cochrane Library and other important databases up to November 2009 (Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). We found six systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. In this systematic review we present information relating to the effectiveness and safety of the following interventions: corticosteroids, mydriatics, and non-steroidal anti-inflammatory drug eye drops.

  16. Properties of Ultra-Violet Cured Poly(diemthylsiloxane)-Urea Acrylates.

    DTIC Science & Technology

    1984-11-01

    reactive diluent content on the properties of UV-cured urethane acrylates. These systems were based on either toluene diisocyanate (TDI) or...procedure by sequentially tipping a difunctional polyether or polyester macroglycol (or polyol) with an aromatic diisocyanate and a hydroxy acrylate such as...hydroxyethyl acrylate (HEA). It is also possible to first react the diisocyanate with HEA (or other hydroxy • acrylate) and then tip the polyol with

  17. The creep behavior of acrylic denture base resins.

    PubMed

    Sadiku, E R; Biotidara, F O

    1996-01-01

    The creep behavior of acrylic dental base resins, at room temperature and at different loading conditions, has been examined. The behaviors of these resins are similar to that of "commercial perspex" at room temperature over a period of 1000 seconds. The pseudo-elastic moduli of the blends of PMMA VC show a significant increase compared with PMMA alone. The addition of the PVC powder to the heat-cured acrylic resin increased the time-dependent elastic modulus. This increase in elastic modulus is advantageous in the production of denture based resins of improv mechanical properties.

  18. Foldable acrylic intraocular lens with distended haptics for transscleral fixation.

    PubMed

    Yaguchi, Saori; Yaguchi, Shigeo; Noda, Yoshiko; Taguchi, Yoko; Negishi, Kazuno; Tsubota, Kazuo

    2009-12-01

    We describe a foldable acrylic intraocular lens (IOL) with distended haptics suitable for transscleral fixation and the insertion procedure. The IOL has an acrylic optic and poly(methyl methacrylate) haptics with a microscopic indentation 1.3 mm from the tip. Transscleral fixation of the IOL was performed through corneal incisions in 22 eyes, and surgical results were retrospectively assessed. The IOL was sutured firmly in position using the cow-hitch procedure, and there was no suture loosening to the distended haptic. The IOL design provided suitable fixation and may be indicated for bag fixation as well as transscleral fixation.

  19. Acrylic Plastic Spherical Pressure Hull for Continental Shelf Depths

    DTIC Science & Technology

    1993-03-01

    29 7. Aluminum 7075-T6 alloy hatch plate for Model AA 30 8. The 15-inch OD x 10.7-inch ID Model BB acrylic sphere with single penetration 30 9...Dimensions of Model BB acrylic sphere 31 10. Removable hatch assembly for Model BB 31 11. Removable aluminum 6061-T6 alloy hatch plate for Models BB and CC...32 12. Aluminum 6061-T6 alloy hatch seat for removable hatches on Models BB and CC 32 13. Plastic bearing gasket for Models BB and CC 33 14. Hatch

  20. Lipase-catalyzed aza-Michael reaction on acrylate derivatives.

    PubMed

    Steunenberg, Peter; Sijm, Maarten; Zuilhof, Han; Sanders, Johan P M; Scott, Elinor L; Franssen, Maurice C R

    2013-04-19

    A methodology has been developed for an efficient and selective lipase-catalyzed aza-Michael reaction of various amines (primary and secondary) with a series of acrylates and alkylacrylates. Reaction parameters were tuned, and under the optimal conditions it was found that Pseudomonas stutzeri lipase and Chromobacterium viscosum lipase showed the highest selectivity for the aza-Michael addition to substituted alkyl acrylates. For the first time also, some CLEAs were examined that showed a comparable or higher selectivity and yield than the free enzymes and other formulations.

  1. (E)-Methyl 2-benzyl-3-o-tolyl-acrylate.

    PubMed

    Karthikeyan, S; Sethusankar, K; Devaraj, Anthonisamy; Bakthadoss, Manickam

    2012-05-01

    In the title compound, C(18)H(18)O(2), the methyl acrylate substituent adopts an extended E conformation with all torsion angles close to 180°. The mean plane of the acrylate unit and the phenyl ring are approximately orthogonal to each other, making a dihedral angle of 81.40 (6)°. The position of the carbonyl group with respect to the olefinic double bond is typically S-trans. The crystal packing is stabilized by inter-molecular C-H⋯π inter-actions.

  2. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under this...

  3. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). Link to an amendment published at 79 FR 34636... substances identified generically as salt of an acrylate copolymer (PMNs P-00-0333 and P-00-0334) are...

  4. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  5. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  6. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  7. 40 CFR 721.338 - Salt of an acrylate copolymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Salt of an acrylate copolymer (generic... Substances § 721.338 Salt of an acrylate copolymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substances identified generically as salt of an acrylate...

  8. 40 CFR 721.10192 - Amides, coco, N-[3-(dibutylamino)propyl], acrylates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Amides, coco, N- , acrylates. 721... Substances § 721.10192 Amides, coco, N- , acrylates. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as amides, coco, N- , acrylates (PMN...

  9. 40 CFR 721.10192 - Amides, coco, N-[3-(dibutylamino)propyl], acrylates.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Amides, coco, N- , acrylates. 721... Substances § 721.10192 Amides, coco, N- , acrylates. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as amides, coco, N- , acrylates (PMN...

  10. 40 CFR 721.10192 - Amides, coco, N-[3-(dibutylamino)propyl], acrylates.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Amides, coco, N- , acrylates. 721... Substances § 721.10192 Amides, coco, N- , acrylates. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as amides, coco, N- , acrylates (PMN...

  11. 40 CFR 721.10192 - Amides, coco, N-[3-(dibutylamino)propyl], acrylates.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Amides, coco, N- , acrylates. 721... Substances § 721.10192 Amides, coco, N- , acrylates. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified as amides, coco, N- , acrylates (PMN...

  12. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  13. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  14. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section...

  15. 40 CFR 180.1162 - Acrylate polymers and copolymers; exemption from the requirement of a tolerance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Acrylate polymers and copolymers... RESIDUES IN FOOD Exemptions From Tolerances § 180.1162 Acrylate polymers and copolymers; exemption from the requirement of a tolerance. (a) Acrylate polymers and copolymers are exempt from the requirement of...

  16. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  17. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626)...

  18. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  19. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

  20. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting...

  1. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under...

  2. 40 CFR 180.1162 - Acrylate polymers and copolymers; exemption from the requirement of a tolerance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 24 2011-07-01 2011-07-01 false Acrylate polymers and copolymers... RESIDUES IN FOOD Exemptions From Tolerances § 180.1162 Acrylate polymers and copolymers; exemption from the requirement of a tolerance. (a) Acrylate polymers and copolymers are exempt from the requirement of...

  3. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting under...

  4. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject to...

  5. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  6. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  7. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  8. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  9. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  10. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  11. 40 CFR 721.9640 - Salt of an acrylic acid - acrylamide terpolymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Salt of an acrylic acid - acrylamide... Specific Chemical Substances § 721.9640 Salt of an acrylic acid - acrylamide terpolymer (generic). (a... generically as salt of an acrylic acid - acrylamide terpolymer (PMN P-99-817) is subject to reporting...

  12. 40 CFR 721.321 - Substituted acrylamides and acrylic acid copolymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Substituted acrylamides and acrylic... New Uses for Specific Chemical Substances § 721.321 Substituted acrylamides and acrylic acid copolymer... identified generically as substituted acrylamides and acrylic acid copolymer (PMN P-00-0490) is subject...

  13. 40 CFR 180.1162 - Acrylate polymers and copolymers; exemption from the requirement of a tolerance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Acrylate polymers and copolymers... RESIDUES IN FOOD Exemptions From Tolerances § 180.1162 Acrylate polymers and copolymers; exemption from the requirement of a tolerance. (a) Acrylate polymers and copolymers are exempt from the requirement of...

  14. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-methyl acrylate copolymer resins. 177.1340... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used as articles or components...

  15. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ethylene-methyl acrylate copolymer resins. 177... for Use as Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used...

  16. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ethylene-methyl acrylate copolymer resins. 177... for Use as Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used...

  17. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Ethylene-methyl acrylate copolymer resins. 177... Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl... section, the ethylene-methyl acrylate copolymer resins consist of basic copolymers produced by...

  18. 21 CFR 177.1340 - Ethylene-methyl acrylate copolymer resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ethylene-methyl acrylate copolymer resins. 177... for Use as Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1340 Ethylene-methyl acrylate copolymer resins. Ethylene-methyl acrylate copolymer resins may be safely used...

  19. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane...

  20. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting under...

  1. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting under...

  2. 40 CFR 180.1162 - Acrylate polymers and copolymers; exemption from the requirement of a tolerance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Acrylate polymers and copolymers... RESIDUES IN FOOD Exemptions From Tolerances § 180.1162 Acrylate polymers and copolymers; exemption from the requirement of a tolerance. (a) Acrylate polymers and copolymers are exempt from the requirement of a...

  3. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section for...

  4. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane...

  5. 40 CFR 180.1162 - Acrylate polymers and copolymers; exemption from the requirement of a tolerance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Acrylate polymers and copolymers... RESIDUES IN FOOD Exemptions From Tolerances § 180.1162 Acrylate polymers and copolymers; exemption from the requirement of a tolerance. (a) Acrylate polymers and copolymers are exempt from the requirement of a...

  6. 40 CFR 721.10032 - Acrylic acid, polymer with substituted acrylamides (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.10032 Acrylic acid, polymer with substituted acrylamides (generic). (a... generically as acrylic acid, polymer with substituted acrylamides (PMN P-02-269) is subject to reporting under...

  7. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section for...

  8. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626) is...

  9. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under this...

  10. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626) is...

  11. 40 CFR 721.10223 - Styrenyl surface treated manganese ferrite with acrylic ester polymer (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ferrite with acrylic ester polymer (generic). 721.10223 Section 721.10223 Protection of Environment... manganese ferrite with acrylic ester polymer (generic). (a) Chemical substance and significant new uses... manganese ferrite with acrylic ester polymer (PMN P-09-582) is subject to reporting under this section for...

  12. 40 CFR 721.463 - Acrylate of polymer based on isophorone diisocyanate (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylate of polymer based on... New Uses for Specific Chemical Substances § 721.463 Acrylate of polymer based on isophorone... substance identified generically as acrylate of polymer based on isophorone diisocyanate (PMN P-00-0626) is...

  13. 40 CFR 721.6560 - Acrylic acid, polymer with substituted ethene.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Acrylic acid, polymer with substituted... Specific Chemical Substances § 721.6560 Acrylic acid, polymer with substituted ethene. (a) Chemical... as acrylic acid, polymer with substituted ethene (PMN P-91-521) is subject to reporting under this...

  14. 40 CFR 721.6920 - Butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Butyl acrylate, polymer with... acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane. (a... butyl acrylate, polymer with substituted methyl styrene, methyl methacrylate, and substituted silane...

  15. High Speed Edge Detection

    NASA Technical Reports Server (NTRS)

    Prokop, Norman F (Inventor)

    2015-01-01

    Analog circuits for detecting edges in pixel arrays are disclosed. A comparator may be configured to receive an all pass signal and a low pass signal for a pixel intensity in an array of pixels. A latch may be configured to receive a counter signal and a latching signal from the comparator. The comparator may be configured to send the latching signal to the latch when the all pass signal is below the low pass signal minus an offset. The latch may be configured to hold a last negative edge location when the latching signal is received from the comparator.

  16. High Speed Edge Detection

    NASA Technical Reports Server (NTRS)

    Prokop, Norman F (Inventor)

    2016-01-01

    Analog circuits for detecting edges in pixel arrays are disclosed. A comparator may be configured to receive an all pass signal and a low pass signal for a pixel intensity in an array of pixels. A latch may be configured to receive a counter signal and a latching signal from the comparator. The comparator may be configured to send the latching signal to the latch when the all pass signal is below the low pass signal minus an offset. The latch may be configured to hold a last negative edge location when the latching signal is received from the comparator.

  17. Scheimpflug imaging in anterior megalophthalmos

    PubMed Central

    Nemeth, Gabor; Hassan, Ziad; Berta, Andras; Modis, Laszlo

    2013-01-01

    We report an anterior megalophthalmos case with decreased corneal thickness and show the findings using Scheimpflug imaging. A 25-year-old male was diagnosed with anterior megalophthalmos. In both eyes, enlarged corneal length was measured. Beside a comparatively good visual acuity, a thin but clear cornea, a fairly deep anterior chamber, and central lens opacity were found. Scheimpflug images were taken using Pentacam HR. Scheimpflug-based imaging can provide us new data at the examination of this syndrome affecting the whole anterior segment. PMID:23275220

  18. Bioengineered anterior cruciate ligament

    NASA Technical Reports Server (NTRS)

    Altman, Gregory (Inventor); Kaplan, David (Inventor); Vunjak-Novakovic, Gordana (Inventor); Martin, Ivan (Inventor)

    2001-01-01

    The present invention provides a method for producing an anterior cruciate ligament ex vivo. The method comprises seeding pluripotent stem cells in a three dimensional matrix, anchoring the seeded matrix by attachment to two anchors, and culturing the cells within the matrix under conditions appropriate for cell growth and regeneration, while subjecting the matrix to one or more mechanical forces via movement of one or both of the attached anchors. Bone marrow stromal cells are preferably used as the pluripotent cells in the method. Suitable matrix materials are materials to which cells can adhere, such as a gel made from collagen type I. Suitable anchor materials are materials to which the matrix can attach, such as Goinopra coral and also demineralized bone. Optimally, the mechanical forces to which the matrix is subjected mimic mechanical stimuli experienced by an anterior cruciate ligament in vivo. This is accomplished by delivering the appropriate combination of tension, compression, torsion, and shear, to the matrix. The bioengineered ligament which is produced by this method is characterized by a cellular orientation and/or matrix crimp pattern in the direction of the applied mechanical forces, and also by the production of collagen type I, collagen type III, and fibronectin proteins along the axis of mechanical load produced by the mechanical forces. Optimally, the ligament produced has fiber bundles which are arranged into a helical organization. The method for producing an anterior cruciate ligament can be adapted to produce a wide range of tissue types ex vivo by adapting the anchor size and attachment sites to reflect the size of the specific type of tissue to be produced, and also adapting the specific combination of forces applied, to mimic the mechanical stimuli experienced in vivo by the specific type of tissue to be produced. The methods of the present invention can be further modified to incorporate other stimuli experienced in vivo by the

  19. Anterior hip pain.

    PubMed

    O'Kane, J W

    1999-10-15

    Anterior hip pain is a common complaint with many possible causes. Apophyseal avulsion and slipped capital femoral epiphysis should not be overlooked in adolescents. Muscle and tendon strains are common in adults. Subsequent to accurate diagnosis, strains should improve with rest and directed conservative treatment. Osteoarthritis, which is diagnosed radiographically, generally occurs in middle-aged and older adults. Arthritis in younger adults should prompt consideration of an inflammatory cause. A possible femoral neck stress fracture should be evaluated urgently to prevent the potentially significant complications associated with displacement. Patients with osteitis pubis should be educated about the natural history of the condition and should undergo physical therapy to correct abnormal pelvic mechanics. "Sports hernias," nerve entrapments and labral pathologic conditions should be considered in athletic adults with characteristic presentations and chronic symptoms. Surgical intervention may allow resumption of pain-free athletic activity.

  20. Swords with Blunt Edges

    ERIC Educational Resources Information Center

    Popham, W. James

    2004-01-01

    Many U.S. educators now wonder whether they're teachers or targets. This mentality stems from the specter of their school being sanctioned for failing the state accountability tests mandated under No Child Left Behind (NCLB). According to this author, most of those tests are like blunt-edged swords: They function badly in two directions. While…

  1. The Inner Urban Edge

    ERIC Educational Resources Information Center

    Ferebee, Ann; Carpenter, Edward K.

    1974-01-01

    In this article, renewal of the inner urban edge is discussed. Norfolk (Virginia) is attempting to blur the difference between old and new neighbor hoods through zoning and architectural controls. Cincinnati (Ohio) is developing an environmentally sound hillside design. Reading (Pennsylvania) is utilizing old railyards for greenbelts of hiking and…

  2. Restoring the incisal edge.

    PubMed

    Terry, Douglas A

    2005-01-01

    Restorative dentistry evolves with each development of new material and innovative technique. Selection of improved restorative materials that simulate the physical properties and other characteristics of natural teeth, in combination with restorative techniques such as the proximal adaptation and incremental layering, provide the framework that ensures the optimal development of an esthetic restoration. These advanced placement techniques offer benefits such as enhanced chromatic integration, polychromatism, ideal anatomical form and function, optimal proximal contact, improved marginal integrity and longer lasting directly placed composite restorations. The purpose of this article is to give the reader a better understanding of the complex restorative challenge in achieving true harmonization of the primary parameters in esthetics (that is, color, shape and texture) represented by the replacement of a single anterior tooth. The case presented demonstrates the restoration of a Class IV fracture integrating basic adhesive principles with these placement techniques and a recently developed nanoparticle hybrid composite resin system (Premise, Kerr/Sybron, Orange, CA). The clinical presentation describes preoperative considerations, tooth preparation, development of the body layer, internal characterization with tints, development of the artificial enamel layer, shaping and contouring, and polishing of a Class IV composite restoration. The clinical significance is that anterior tooth fractures can be predictably restored using contemporary small particle hybrid composite resin systems with the aforementioned restorative techniques. These placement techniques when used with proper attention to preparation design, adhesive protocol and finishing and polishing procedures, allow the clinician to successfully restore form, function and esthetics to the single anterior tooth replacement.

  3. Acrylic Triblock Copolymers Incorporating Isosorbide for Pressure Sensitive Adhesives

    SciTech Connect

    Gallagher, James J.; Hillmyer, Marc A.; Reineke, Theresa M.

    2016-05-10

    A new monomer acetylated acrylic isosorbide (AAI) was prepared in two steps using common reagents without the need for column chromatography. Free radical polymerization of AAI afforded poly(acetylated acrylic isosorbide) (PAAI), which exhibited a glass transition temperature (Tg) = 95 °C and good thermal stability (Td, 5% weight loss; N2 = 331 °C, air = 291 °C). A series of ABA triblock copolymers with either poly(n-butyl acrylate) (PnBA) or poly(2-ethylhexyl acrylate) (PEHA) as the low Tg midblocks and PAAI as the high Tg end blocks were prepared using Reversible Addition–Fragmentation chain Transfer (RAFT) polymerization. The triblock copolymers ranging from 8–24 wt % PAAI were evaluated as pressure sensitive adhesives by 180° peel, loop tack, and static shear testing. While the PAAI-PEHA-PAAI series exhibited poor adhesive qualities, the PAAI-PnBA-PAAI series of triblock copolymers demonstrated peel forces up to 2.9 N cm–1, tack forces up to 3.2 N cm–1, and no shear failure up to 10000 min. Dynamic mechanical analysis indicated that PAAI-PEHA-PAAI lacked the dissipative qualities needed to form an adhesive bond with the substrate, while the PAAI-PnBA-PAAI series exhibited a dynamic mechanical response consistent with related high performing PSAs.

  4. Acrylic acid and electric power cogeneration in an SOFC reactor.

    PubMed

    Ji, Baofeng; Wang, Jibo; Chu, Wenling; Yang, Weishen; Lin, Liwu

    2009-04-21

    A highly efficient catalyst, MoV(0.3)Te(0.17)Nb(0.12)O, used for acrylic acid (AA) production from propane, was used as an anodic catalyst in an SOFC reactor, from which AA and electric power were cogenerated at 400-450 degrees C.

  5. Investigation into nanocellulosics versus acacia reinforced acrylic films

    Treesearch

    Yunqiao Pu; Jianguo Zhang; Thomas Elder; Yulin Deng; Paul Gatenholm; Arthur J. Ragauskas

    2007-01-01

    Three closely related cellulosic acrylic latex films were prepared employing acacia pulp fibers, cellulose whiskers and nonocellulose balls and their respective strength properties were determined. Cellulose whisker reinforced composites had enhanced strength properties compared to the acacia pulp and nanoball composites. AFM analysis indicated that the cellulose...

  6. Synthesis and Reactivity of Aluminized Fluorinated Acrylic (AIFA) Nanocomposites (Postprint)

    DTIC Science & Technology

    2012-06-18

    REACTIVITY OF ALUMINIZED FLUORINATED ACRYLIC (ALFA) NANOCOMPOSITES (POSTPRINT) 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...the nano Al throughout the material, the composite was compounded for 3 min in a DACA Instruments benchtop twin screw extruder at 150 C. The com

  7. Acrylic resin injection method for blood vessel investigations.

    PubMed

    Suwa, Fumihiko; Uemura, Mamoru; Takemura, Akimichi; Toda, Isumi; Fang, Yi-Ru; Xu, Yuan Jin; Zhang, Zhi Yuan

    2013-01-01

    The injection of acrylic resin into vessels is an excellent method for macroscopically and microscopically observing their three-dimensional features. Conventional methods can be enhanced by removal of the polymerization inhibitor (hydroquinone) without requiring distillation, a consistent viscosity of polymerized resin, and a constant injection pressure and speed. As microvascular corrosion cast specimens are influenced by viscosity, pressure, and speed changes, injection into different specimens yields varying results. We devised a method to reduce those problems. Sodium hydroxide was used to remove hydroquinone from commercial methylmethacrylate. The solid polymer and the liquid monomer were mixed using a 1 : 9 ratio (low-viscosity acrylic resin, 9.07 ± 0.52 mPa•s) or a 3:7 ratio (high-viscosity resin, 1036.33 ± 144.02 mPa•s). To polymerize the acrylic resin for injection, a polymerization promoter (1.0% benzoyl peroxide) was mixed with a polymerization initiator (0.5%, N, N-dimethylaniline). The acrylic resins were injected using a precise syringe pump, with a 5-mL/min injection speed and 11.17 ± 1.60 mPa injection pressure (low-viscosity resin) and a 1-mL/min injection speed and 58.50 ± 5.75 mPa injection pressure (high-viscosity resin). Using the aforementioned conditions, scanning electron microscopy indicated that sufficient resin could be injected into the capillaries of the microvascular corrosion cast specimens.

  8. Mid-infrared laser ablation of intraocular acrylic lenses

    NASA Astrophysics Data System (ADS)

    Spyratou, E.; Makropoulou, M.; Bacharis, C.; Serafetinides, A. A.

    2007-05-01

    Ablation rates measurements with free-running Er:YAG laser (λ=2.94 μm) were performed in hydrophilic acrylic intraocular lenses. We studied the role of water in the laser ablation mechanisms by using hydrophilic lenses with different concentrations of H II0 and D II0. A mathematical model simulated the experimental results.

  9. 40 CFR 721.5325 - Nickel acrylate complex.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.5325 Nickel acrylate complex. Link to an amendment published at 79 FR 34637, June 18, 2014. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical...

  10. JKR studies of adhesion with model acrylic elastomers

    SciTech Connect

    Shull, K.R.; Ahn, D.

    1996-12-31

    Acrylic elastomers are widely used in coating applications because of their inherent thermal stability, oil resistance and adhesive properties. These same features make acrylic elastomers attractive for fundamental studies of polymer adhesion. This endeavor has been simplified recently by the development of techniques for producing monodisperse acrylic homopolymers and block copolymers from anionically synthesized parent polyacrylates, thus allowing precise microstructural control of adhering surfaces. In terms of the adhesion measurement itself, an adhesion test based upon the theory of Johnson, Kendall and Roberts (JKR), henceforth referred to as the JKR technique, is well suited for probing the molecular origins of adhesion in elastomeric systems. This technique is quite practical, and minimizes the sample volume to reduce bulk viscoelastic losses. Further, the JKR technique permits testing at very low crack velocities, where interfacial effects are unobscured by bulk effects. In this paper, the authors report the results of JKR adhesion tests between poly(n-butyl acrylate) (PNBA) elastomers and poly(methyl methacrylate) (PMMA). The latter is employed as a control substrate because its inertness and low surface energy (relative to metallic or silicon based surfaces) are conducive to the creation of reproducible solid surfaces.

  11. Interactions of sodium montmorillonite with poly(acrylic acid).

    PubMed

    Tran, Nguyen H; Dennis, Gary R; Milev, Adriyan S; Kannangara, G S Kamali; Wilson, Michael A; Lamb, Robert N

    2005-10-15

    The chemical-structural modifications of the natural clay sodium montmorillonite during interaction with poly(acrylic acid) were studied mainly by X-ray photoemission spectroscopy. Samples of modified montmorillonite were prepared from the reaction of sodium montmorillonite ( approximately 0.5 g) and an aqueous solution of poly(acrylic acid) (pH approximately 1.8, 50 g) at varying temperatures. X-ray diffraction indicated that the montmorillonite interlayer space ( approximately 13 A), formed by regular stacking of the silicate layers (dimension approximately 1x1000 nm), expanded to approximately 16 A as the reaction was carried out at room temperature and at 30 degrees C. At 60 degrees C, the interlayer space further expanded to approximately 20 A. The results of X-ray photoemission spectroscopy indicated that poly(acrylic acid) molecules exchange sodium ions on the surface of the silicate layers. These combined results allowed development of a reaction model that explains the dependency of the interlayer expansion with temperature. Information concerning the surface chemical reactions and systematic increases in the interlayer distances is particularly useful if montmorillonite and poly(acrylic acid) are to be used for formation of nanocomposite materials.

  12. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... emulsion defoamer. Disodium hydrogen phosphate Do. Formaldehyde Glyceryl monostearate Methyl cellulose... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  13. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... amount required as a preservative in emulsion defoamer. Disodium hydrogen phosphate Do. Formaldehyde... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  14. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... emulsion defoamer. Disodium hydrogen phosphate Do. Formaldehyde Glyceryl monostearate Methyl cellulose... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Acrylate ester copolymer coating. 175.210 Section 175.210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  15. 21 CFR 177.1320 - Ethylene-ethyl acrylate copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... blended with polyethylene or with one or more olefin copolymers complying with § 177.1520 or with a mixture of polyethylene and one or more olefin copolymers, in such proportions that the ethyl acrylate... prescribed in paragraph (c)(2) of this section, when tested by the methods prescribed for polyethylene...

  16. Regioselectivity of enzymatic modification of poly(methyl acrylate).

    PubMed

    Inprakhon, Pranee; Lalot, Thierry

    2007-09-30

    Enzymes are potentially useful catalysts for polymerization as well as modification of polymers. While lipases have been used previously for polymerization reactions, they have not been used for modification of polymers. In this report, lipases were used to determine regioselective modification of ester functions in a telomer of poly(methyl acrylate). The influence of chain length on the extent of transesterification of methyl acrylate telomers of DP(n) 6-50 was studied by examining the relationship between the extents of enzymic modification to other telomerization parameters. The regioselectivity was observed when the average DP(n) of telomers is in a range of 6-22. At a higher DP(n) (>22), however, the average number of reacting ester functions per telomer strongly deviated from the theoretically predicted value. This phenomenon was suspected as a result of steric hindrance caused by folding of longer telomer chains. To verify this hypothesis, acrylate telomers at a DP(n) ranging from 10 to 42 were synthesized using a shorter telogen, i.e., 2,2'-ethanedithiol. The transesterification of these telomers showed a deviation in a degree of conversion when DP(n) was greater than 10, possibly indicating the inhibition caused by steric hindrance. Therefore, regioselective modification of acrylic polymers, which is difficult to achieve by conventional chemical methods, may be accomplished enzymatically.

  17. Degradation of a Sodium Acrylate Oligomer by an Arthrobacter sp

    PubMed Central

    Hayashi, Takaya; Mukouyama, Masaharu; Sakano, Kouichi; Tani, Yoshiki

    1993-01-01

    Arthrobacter sp. strain NO-18 was first isolated from soil as a bacterium which could degrade the sodium acrylate oligomer and utilize it as the sole source of carbon. When 0.2% (wt/wt) oligomer was added to the culture medium, the acrylate oligomer was found to be degraded by 70 to 80% in 2 weeks, using gel permeation chromatography. To determine the maximum molecular weight for biodegradation, the degradation test was done with the hexamer, heptamer, and octamer, which were separated from the oligomer mixture by fractional gel permeation chromatography. The hexamer and heptamer were consumed to the extents of 58 and 36%, respectively, in 2 weeks, but the octamer was not degraded. Oligomers with three different terminal groups were synthesized to examine the effect of the different terminal groups on biodegradation, but few differences were found. Arthrobacter sp. NO-18 assimilated acrylic acid, propionic acid, glutaric acid, 2-methylglutaric acid, and 1,3,5-pentanetricarboxylic acid. Degradation of the acrylic unit structure by this strain is discussed. PMID:8517751

  18. Antimicrobial activity of poly(acrylic acid) block copolymers.

    PubMed

    Gratzl, Günther; Paulik, Christian; Hild, Sabine; Guggenbichler, Josef P; Lackner, Maximilian

    2014-05-01

    The increasing number of antibiotic-resistant bacterial strains has developed into a major health problem. In particular, biofilms are the main reason for hospital-acquired infections and diseases. Once formed, biofilms are difficult to remove as they have specific defense mechanisms against antimicrobial agents. Antimicrobial surfaces must therefore kill or repel bacteria before they can settle to form a biofilm. In this study, we describe that poly(acrylic acid) (PAA) containing diblock copolymers can kill bacteria and prevent from biofilm formation. The PAA diblock copolymers with poly(styrene) and poly(methyl methacrylate) were synthesized via anionic polymerization of tert-butyl acrylate with styrene or methyl methacrylate and subsequent acid-catalyzed hydrolysis of the tert-butyl ester. The copolymers were characterized via nuclear magnetic resonance spectroscopy (NMR), size-exclusion chromatography (SEC), Fourier transform infrared spectroscopy (FTIR), elemental analysis, and acid-base titrations. Copolymer films with a variety of acrylic acid contents were produced by solvent casting, characterized by atomic force microscopy (AFM) and tested for their antimicrobial activity against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. The antimicrobial activity of the acidic diblock copolymers increased with increasing acrylic acid content, independent of the copolymer-partner, the chain length and the nanostructure. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Humidity-responsive starch-poly (methyl acrylate) films.

    USDA-ARS?s Scientific Manuscript database

    Blown films prepared from starch-poly(methyl acrylate) graft copolymers plasticized with urea and water display shrinkage at relative humidities greater than 50%. Shrinkage at relative humidities below approximately 75% is strongly correlated with the urea/starch weight ratio, which controls the eq...

  20. Microhardness of heat cure acrylic resin after treatment with disinfectants.

    PubMed

    Amin, Faiza; Rehman, Abdur; Abbas, Muhammad

    2015-08-01

    To evaluate the effect of disinfectants and distilled water on the micro-hardness of heat cure acrylic resins. The case-control study was conducted at Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, and Nadirshaw Edulji Dinshaw University of Engineering and Technology, Karachi, from April to October 2011. Specimens were fabricated from heat cure acrylic resin material and they were divided into four equal groups. Group 1 was evaluated at baseline and was taken as the control group. Group 2 was immersed in distilled water for 20 minutes, Group 3 in1% sodium hypochlorite for 20 minutes, and Group 4 in 2% alkaline gluteraldehyde for 10 minutes. All specimens were polished, stored in distilled water for 24 hours prior to experiment. All the specimens were immersed twice daily for a total of 60 days after which they were tested for Vickers micro-hardness test. Statistical analysis was conducted with one-way analysis of variance and Tukey post hoc test (a=0.05). There were 72 specimens divided into four groups of 18(25%) each. Statistically significant differences were found among all groups (p<0.0001). The storage medium had an effect on the micro-hardness of heat cure acrylic resins. Group 4 showed the most reduction in the hardness value which was followed by Group 3. The hardness of heat cure acrylic resin was affected by disinfectants.

  1. Adjacent Segment Pathology after Anterior Cervical Fusion

    PubMed Central

    Chung, Jae Yoon; Park, Jong-Beom; Seo, Hyoung-Yeon

    2016-01-01

    Anterior cervical fusion has become a standard of care for numerous pathologic conditions of the cervical spine. However, subsequent development of clinically significant disc disease at levels adjacent to fused discs is a serious long-term complication of this procedure. As more patients live longer after surgery, it is foreseeable that adjacent segment pathology (ASP) will develop in increasing numbers of patients. Also, ASP has been studied more intensively with the recent popularity of motion preservation technologies like total disc arthroplasty. The true nature and scope of ASP remains poorly understood. The etiology of ASP is most likely multifactorial. Various factors including altered biomechanical stresses, surgical disruption of soft tissue and the natural history of cervical disc disease contribute to the development of ASP. General factors associated with disc degeneration including gender, age, smoking and sports may play a role in the development of ASP. Postoperative sagittal alignment and type of surgery are also considered potential causes of ASP. Therefore, a spine surgeon must be particularly careful to avoid unnecessary disruption of the musculoligamentous structures, reduced risk of direct injury to the disc during dissection and maintain a safe margin between the plate edge and adjacent vertebrae during anterior cervical fusion. PMID:27340541

  2. Sensitization capacity of acrylated prepolymers in ultraviolet curing inks tested in the guinea pig.

    PubMed

    Björkner, B

    1981-01-01

    One commonly used prepolymer in ultraviolet (UV) curing inks is epoxy acrylate. Of 6 men with dermatitis contracted from UV-curing inks, 2 had positive patch test reaction to epoxy acrylate. None reacted to the chemically related bisphenol A dimethacrylate. The sensitization capacity of epoxy acrylate and bisphenol A dimethacrylate performed with the "Guinea pig maximization test" (GPM) shows epoxy acrylate to be an extreme sensitizer and bisphenol A dimethacrylate a moderate sensitizer. Cross-reaction between the two substances occurs. The epoxy resin oligomer MW 340 present in the epoxy acrylate also sensitized some animals.

  3. [Anterior cervical hypertrichosis: case report].

    PubMed

    Orozco-Gutiérrez, Mario H; Sánchez-Corona, José; García-Ortiz, José E; Castañeda-Cisneros, Gema; Dávalos-Rodríguez, Nory O; Corona-Rivera, Jorge R; García-Cruz, Diana

    2016-10-01

    The non-syndromic anterior cervical hypertrichosis (OMIM N° 600457) is a genetic disorder characterized by a patch of hair at the level of the laryngeal prominence. We present a 12-year-old boy with anterior cervical hypertrichosis and mild generalized hypertrichosis. He has no neurological, ophthalmological or skeletal anomalies. The clinical follow up is 10 years.

  4. Features extraction in anterior and posterior cruciate ligaments analysis.

    PubMed

    Zarychta, P

    2015-12-01

    The main aim of this research is finding the feature vectors of the anterior and posterior cruciate ligaments (ACL and PCL). These feature vectors have to clearly define the ligaments structure and make it easier to diagnose them. Extraction of feature vectors is obtained by analysis of both anterior and posterior cruciate ligaments. This procedure is performed after the extraction process of both ligaments. In the first stage in order to reduce the area of analysis a region of interest including cruciate ligaments (CL) is outlined in order to reduce the area of analysis. In this case, the fuzzy C-means algorithm with median modification helping to reduce blurred edges has been implemented. After finding the region of interest (ROI), the fuzzy connectedness procedure is performed. This procedure permits to extract the anterior and posterior cruciate ligament structures. In the last stage, on the basis of the extracted anterior and posterior cruciate ligament structures, 3-dimensional models of the anterior and posterior cruciate ligament are built and the feature vectors created. This methodology has been implemented in MATLAB and tested on clinical T1-weighted magnetic resonance imaging (MRI) slices of the knee joint. The 3D display is based on the Visualization Toolkit (VTK). Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Superpixel edges for boundary detection

    SciTech Connect

    Moya, Mary M.; Koch, Mark W.

    2016-07-12

    Various embodiments presented herein relate to identifying one or more edges in a synthetic aperture radar (SAR) image comprising a plurality of superpixels. Superpixels sharing an edge (or boundary) can be identified and one or more properties of the shared superpixels can be compared to determine whether the superpixels form the same or two different features. Where the superpixels form the same feature the edge is identified as an internal edge. Where the superpixels form two different features, the edge is identified as an external edge. Based upon classification of the superpixels, the external edge can be further determined to form part of a roof, wall, etc. The superpixels can be formed from a speckle-reduced SAR image product formed from a registered stack of SAR images, which is further segmented into a plurality of superpixels. The edge identification process is applied to the SAR image comprising the superpixels and edges.

  6. Shape of patch edges affects edge permeability for meadow voles.

    PubMed

    Nams, Vilis O

    2012-09-01

    Human development typically fragments natural habitats into patches, affecting population and metapopulation dynamics via changes in animal behavior. Emigration from one habitat patch to another has a large effect on population and metapopulation dynamics. One factor that affects emigration is permeability of patch edges. This study looks at the effects of edge shape (convex, concave, and straight) on edge permeability for meadow voles (Microtus pennsylvanicus).. I tested five hypotheses for responses of animal movement to patch shape: (1) neutral edge response; (2) edge attraction; (3) edge avoidance; (4) time-minimizing, in which an animal attempts to minimize the time spent in inhospitable matrix, and thus travels as far as possible in the patch before crossing the edge; and (5) protection, in which an animal attempts to maximize protection while in the inhospitable matrix by keeping the patch close by. These hypotheses were tested by an experimental manipulation of meadow vole habitats. A strip was mowed with different edge shapes through an old field, and vole response was measured by tracking plates. Voles crossed edges at concave treatments twice as often compared to convex and straight shapes. Hypotheses (2) and (5) were supported. Although edge attraction causes a passive effect of a decrease in edge-crossing at concavities, this effect was eclipsed by the active effect of voles choosing to cross at concavities. The results can be generalized to edge tortuosity in general. Conservation biologists should consider edge shapes when exploring the effects of habitat fragmentation on animal populations.

  7. Synthesis and Characterization of Polyurethane Acrylates for UV Curable Coating Agents

    NASA Astrophysics Data System (ADS)

    Park, Mi Na; Kang, Young Soo; Oh, Sun Wha; Ahn, Byung Hyun; Moon, Myung Jun

    The single hydroxyl-terminated urethane acrylate oligomers were synthesized from 2-mercaptoethanol (2-MEOH), alkyl (methyl, butyl, and 2-ethylhexyl) acrylate, and 2,2-azobisisobutyronitrile (AIBN, initiator), with dibutyltin dilaurate (DBTDL) as a catalyst. 2-MEOH was used as a functional chain transfer agent. Poly(alkyl urethane) acrylate oligomers were obtained by the reaction of single hydroxyl-terminated polyalkyl acrylates and 2-isocyanatoethyl acrylate. They were characterized by NMR, FT-IR spectroscopy, rheometer, and DSC. Because poly(alkyl urethane) acrylate oligomers have lower Tg and viscosity than hydroxyl-terminated polyalkyl acrylate oligomers (HTPAO) non-containing urethane groups, they can be used for ultraviolet (UV) curable coatings, inks, and adhesives.

  8. Edge detection by nonlinear dynamics

    SciTech Connect

    Wong, Yiu-fai

    1994-07-01

    We demonstrate how the formulation of a nonlinear scale-space filter can be used for edge detection and junction analysis. By casting edge-preserving filtering in terms of maximizing information content subject to an average cost function, the computed cost at each pixel location becomes a local measure of edgeness. This computation depends on a single scale parameter and the given image data. Unlike previous approaches which require careful tuning of the filter kernels for various types of edges, our scheme is general enough to be able to handle different edges, such as lines, step-edges, corners and junctions. Anisotropy in the data is handled automatically by the nonlinear dynamics.

  9. Drop behavior on a thermally-stripped acrylic polymer: influence of surface tension induced wetting ridge formation on retention and running.

    PubMed

    Pu, Gang; Ai, Jun; Severtson, Steven J

    2010-08-03

    Results are reviewed from a study on retention and running of water and other liquids on tilted, polymer coated surfaces. The polymer is a thermally-stripped, solvent-borne acrylic composed primarily of the monomer 2-ethylhexyl acrylate, providing a soft and viscoelastic substrate absent of contaminants. It is shown that drop retention does not obey standard models, which assume dominance of capillary forces in offsetting drop weight for tilted plates. For these surfaces, maximum volumes correlate with capillary lengths, and distinct deformations, which vary in magnitude depending on location, are apparent over the entire drop perimeter. Deformation images indicate that running, which in real time appears to be continuous motion, actually proceeds through a series of steps beginning with the failure of the front edge wetting line. This produces a relatively large translation of the drop's front edge down the plate surface stretching the drop. This is followed by multiple failures at the rear edge producing a series of small translations, contracting the drop volume to a more spherical-like geometry. Repetition of this mechanism results in the appearance of propagation similar to that employed by an inchworm. The proposed mechanism is consistent with images of drop movement and deformations induced on polymer surfaces, which are apparent subsequent to the running process.

  10. Playing Along the Edge

    NASA Image and Video Library

    2016-08-13

    Strands and arches of plasma streamed above the edge of the Sun for over a day, pulled by powerful magnetic forces (Aug. 11-12, 2016). The tug and pull of material heated to about 60,000 degrees C. was viewed in extreme ultraviolet light. This kind of dynamic flow of materials is rather common, though this grouping was larger than most. http://photojournal.jpl.nasa.gov/catalog/PIA17913

  11. Edge turbulence in tokamaks

    NASA Astrophysics Data System (ADS)

    Nedospasov, A. V.

    1992-12-01

    Edge turbulence is of decisive importance for the distribution of particle and energy fluxes to the walls of tokamaks. Despite the availability of extensive experimental data on the turbulence properties, its nature still remains a subject for discussion. This paper contains a review of the most recent theoretical and experimental studies in the field, including mainly the studies to which Wootton (A.J. Wooton, J. Nucl. Mater. 176 & 177 (1990) 77) referred to most in his review at PSI-9 and those published later. The available theoretical models of edge turbulence with volume dissipation due to collisions fail to fully interpret the entire combination of experimental facts. In the scrape-off layer of a tokamak the dissipation prevails due to the flow of current through potential shifts near the surface of limiters of divertor plates. The different origins of turbulence at the edge and in the core plasma due to such dissipation are discussed in this paper. Recent data on the electron temperature fluctuations enabled one to evaluate the electric probe measurements of turbulent flows of particles and heat critically. The latest data on the suppression of turbulence in the case of L-H transitions are given. In doing so, the possibility of exciting current instabilities in biasing experiments (rather than only to the suppression of existing turbulence) is given some attention. Possible objectives of further studies are also discussed.

  12. Wavelength Shifters and Interactions of EDTA with Acrylic & LAB

    NASA Astrophysics Data System (ADS)

    Mohan, Yuvraj; SNO+ Collaboration

    2014-09-01

    The SNO + experiment, an upgrade to the Sudbury Neutrino Observatory, will use linear alkyl-benzene (LAB) liquid scintillator to probe new physics, including 0 νββ decay. Event detection efficiency is heavily affected by radioactive backgrounds, two sources being Rn-222 and Po-210 daughters, some of which has become embedded in the SNO + acrylic vessel after years underground. The leading candidate for polonium leaching is Ethylenediaminetetraacetic acid (EDTA). Before deployment on-site, EDTA's effects on the mechanical integrity of acrylic must be determined. It also must not be soluble in LAB or must be removed before scintillator fill of the vessel, as its presence would result in reduced light yield due to scattering. It was found that EDTA had negligible effects on the Young's Modulus of acrylic. EDTA is also slightly soluble in LAB, but can be completely removed by rinsing with water. Additionally, the study of the light yield and alpha/beta timing profiles of two wavelength shifters - bisMSB and perylene - is critical to determining which should be added to the 0 νββ isotope (tellurium) LAB cocktail. Small-scale results hint that perylene might be better, but this is being confirmed with larger-scale tests. The SNO + experiment, an upgrade to the Sudbury Neutrino Observatory, will use linear alkyl-benzene (LAB) liquid scintillator to probe new physics, including 0 νββ decay. Event detection efficiency is heavily affected by radioactive backgrounds, two sources being Rn-222 and Po-210 daughters, some of which has become embedded in the SNO + acrylic vessel after years underground. The leading candidate for polonium leaching is Ethylenediaminetetraacetic acid (EDTA). Before deployment on-site, EDTA's effects on the mechanical integrity of acrylic must be determined. It also must not be soluble in LAB or must be removed before scintillator fill of the vessel, as its presence would result in reduced light yield due to scattering. It was found that EDTA

  13. Anterior crossbite correction in primary and mixed dentition with removable inclined plane (Bruckl appliance).

    PubMed

    Jirgensone, Irena; Liepa, Andra; Abeltins, Andris

    2008-01-01

    Anterior crossbite correction in early mixed dentition is highly recommended as this kind of malocclusion do not diminish with age. Uncorrected anterior crossbite may lead to abnormal wear of the lower incisors, dental compensation of mandibular incisors leading to thinning of labial alveolar plate and/or gingival recession. There are several methods for solving this problem. In this article we would like to describe removable inclined plane. This is a removable simple functional appliance on the lower arch (jaw), which works as inclined plane. One of the advantage of the Bruckl appliance is that it can also be used as retention appliance after active treatment as well as it is possible to add acrylic teeth if necessary. Therefore it can be used as a removable partial denture in lower jaw in case where there is a premature loss of the primary teeth. The use of this appliance is illustrated with three cases.

  14. Bilateral spontaneous anterior dislocation of intraocular lens with the capsular bag in a patient with pseudoexfoliation

    PubMed Central

    Bhattacharjee, Harsha; Saxena, Rushil Kumar; Medhi, Jnanankar

    2015-01-01

    We report a rare case of bilateral spontaneous anterior partial in-the-bag intraocular lens (IOL) dislocation in a 75-year-old man with pseudoexfoliation (PXF). He underwent uneventful phacoemulsification in both eyes with in-the-bag IOL implantation 9 years back. In the right eye, single piece poly (methyl methacrylate) (PMMA) IOL (+19 D) and in the left eye, single piece acrylic foldable IOL (+19 D) were implanted. An attempt at pharmacological IOL repositioning was unsuccessful. The dislocated IOLs were explanted and exchanged with scleral suture fixated PMMA IOLs. Vision improved to 20/30 in both eyes following surgery, without any associated ocular morbidity. We believe that zonular weakness secondary to PXF, capsular contraction, and myopia together were the predisposing factors for partial anterior dislocation of IOLs and IOL exchange with scleral suture fixation of IOL is a safe and effective treatment option. PMID:26655008

  15. Simple removable appliances to correct anterior and posterior crossbite in mixed dentition: Case report

    PubMed Central

    Bindayel, Naif A.

    2012-01-01

    Different techniques have been used to correct anterior and posterior crossbites in mixed dentition. This case report illustrates the treatment of anterior and unilateral posterior crossbites during the mixed dentition. The patient was a 9-year-old boy with a crossbite of the maxillary right permanent central incisor and a unilateral right posterior crossbite, both expressed by a functional shift in the sagittal and transverse dimensions. Two upper acrylic removable appliances, each with an expansion jackscrew, were used to correct the crossbites. The total active treatment time was 4 months; the treatment outcomes were successfully maintained for the subsequent 4 months. General and pediatric dentists, as well as orthodontists, may find this technique useful in managing crossbite cases of the mixed dentition and utilizing the discussion and illustrations for further clinical guidance. PMID:23960537

  16. Hydrophilic Acrylic Intraocular Lens Opacification after Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Norouzpour, Amir; Zarei-Ghanavati, Siamak

    2016-01-01

    Purpose: To report hydrophilic acylic intraocular lens (IOL) opacification after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in an eye with multiple prior intraocular surgeries and iatrogenic aniridia. Case Report: A 34-year-old woman with history of penetrating keratoplasty (PKP) for advanced keratoconus and subsequent Urrets-Zavalia Syndrome (UZS) underwent phacoemulsification and hydrophilic acrylic IOL implantation for her cataract. In order to control post-PKP glaucoma, multiple glaucoma surgeries including two glaucoma drainage implants were performed. As the original corneal graft failed, the patient subsequently underwent re-PKP. Four years later, she underwent DSAEK for treatment of the second graft failure. Ten months after DSAEK, a double semi-circular pattern of IOL opacification was observed on the anterior surface of the IOL. The patient did not report any complaints and we decided not to exchange the IOL. Conclusion: In an eye with UZS and iatrogenic aniridia, IOL opacification may result from direct contact between the IOL surface and exogenous air. Aniridia can be a risk factor for development of IOL opacification after DSAEK. Further studies are required to confirm this hypothesis. PMID:27413506

  17. The use of acrylic resin oral prosthesis in radiation therapy of oral cavity and paranasal sinus cancer

    SciTech Connect

    Cheng, V.S.T.; Oral, K.; Aramamy, M.A.

    1982-07-01

    In radiation therapy of cancer of the oral cavity and the paranasal sinuses, the extent to which the tissues of the oral cavity are included in the radiation treatment portals will determine the severity of the oral discomfort during treatment. This will affect the nutritional status of the patients, and may eventually affect the total dose of radiation which the patients can receive for treatment of their cancers. In cooperation with the Maxillofacial Prosthetic Department, an acrylic resin oral prosthesis was developed. This prosthesis is easy to use and can be made for each individual patient within 24 hours. It allows for maximum sparing of the normal tissues in the oral cavity and can be modified for shielding of backscattered electrons from heavy metals in the teeth. We have also found that acrylic resin extensions can be built onto the posterior edge of post-maxillectomy obturators; this extension can be used as a carrier for radioactive sources to deliver radiation to deep seated tumor modules in the paranasal sinuses.

  18. Conservation of artists' acrylic emulsion paints: XPS, NEXAFS and ATR-FTIR studies of wet cleaning methods

    DOE PAGES

    Willneff, E. A.; Ormsby, B. A.; Stevens, J. S.; ...

    2014-02-17

    Works of art prepared with acrylic emulsion paints became commercially available in the 1960s. It is increasingly necessary to undertake and optimise cleaning and preventative conservation treatments to ensure their longevity. Model artists' acrylic paint films covered with artificial soiling were thus prepared on a canvas support and exposed to a variety of wet cleaning treatments based on aqueous or hydrocarbon solvent systems. This included some with additives such as chelating agents and/or surfactants, and microemulsion systems made specifically for conservation practice. The impact of cleaning (soiling removal) on the paint film surface was examined visually and correlated with resultsmore » of attenuated total reflection Fourier transform infrared, XPS and near-edge X-ray absorption fine structure analyses – three spectroscopic techniques with increasing surface sensitivity ranging from approximately $-$ 1000, 10 and 5 nm, respectively. Visual analysis established the relative cleaning efficacy of the wet cleaning treatments in line with previous results. X-ray spectroscopy analysis provided significant additional findings, including evidence for (i) surfactant extraction following aqueous swabbing, (ii) modifications to pigment following cleaning and (iii) cleaning system residues.« less

  19. Conservation of artists' acrylic emulsion paints: XPS, NEXAFS and ATR-FTIR studies of wet cleaning methods†

    PubMed Central

    Willneff, EA; Ormsby, BA; Stevens, JS; Jaye, C; Fischer, DA; Schroeder, SLM

    2014-01-01

    Works of art prepared with acrylic emulsion paints became commercially available in the 1960s. It is increasingly necessary to undertake and optimise cleaning and preventative conservation treatments to ensure their longevity. Model artists' acrylic paint films covered with artificial soiling were thus prepared on a canvas support and exposed to a variety of wet cleaning treatments based on aqueous or hydrocarbon solvent systems. This included some with additives such as chelating agents and/or surfactants, and microemulsion systems made specifically for conservation practice. The impact of cleaning (soiling removal) on the paint film surface was examined visually and correlated with results of attenuated total reflection Fourier transform infrared, XPS and near-edge X-ray absorption fine structure analyses – three spectroscopic techniques with increasing surface sensitivity ranging from approximately − 1000, 10 and 5 nm, respectively. Visual analysis established the relative cleaning efficacy of the wet cleaning treatments in line with previous results. X-ray spectroscopy analysis provided significant additional findings, including evidence for (i) surfactant extraction following aqueous swabbing, (ii) modifications to pigment following cleaning and (iii) cleaning system residues. © 2014 The Authors. Surface and Interface Analysis published by John Wiley & Sons, Ltd. PMID:25892829

  20. Conservation of artists' acrylic emulsion paints: XPS, NEXAFS and ATR-FTIR studies of wet cleaning methods.

    PubMed

    Willneff, E A; Ormsby, B A; Stevens, J S; Jaye, C; Fischer, D A; Schroeder, Slm

    2014-01-01

    Works of art prepared with acrylic emulsion paints became commercially available in the 1960s. It is increasingly necessary to undertake and optimise cleaning and preventative conservation treatments to ensure their longevity. Model artists' acrylic paint films covered with artificial soiling were thus prepared on a canvas support and exposed to a variety of wet cleaning treatments based on aqueous or hydrocarbon solvent systems. This included some with additives such as chelating agents and/or surfactants, and microemulsion systems made specifically for conservation practice. The impact of cleaning (soiling removal) on the paint film surface was examined visually and correlated with results of attenuated total reflection Fourier transform infrared, XPS and near-edge X-ray absorption fine structure analyses - three spectroscopic techniques with increasing surface sensitivity ranging from approximately - 1000, 10 and 5 nm, respectively. Visual analysis established the relative cleaning efficacy of the wet cleaning treatments in line with previous results. X-ray spectroscopy analysis provided significant additional findings, including evidence for (i) surfactant extraction following aqueous swabbing, (ii) modifications to pigment following cleaning and (iii) cleaning system residues. © 2014 The Authors. Surface and Interface Analysis published by John Wiley & Sons, Ltd.

  1. Conservation of artists' acrylic emulsion paints: XPS, NEXAFS and ATR-FTIR studies of wet cleaning methods

    SciTech Connect

    Willneff, E. A.; Ormsby, B. A.; Stevens, J. S.; Jaye, C.; Fischer, D. A.; Schroeder, S. L. M.

    2014-02-17

    Works of art prepared with acrylic emulsion paints became commercially available in the 1960s. It is increasingly necessary to undertake and optimise cleaning and preventative conservation treatments to ensure their longevity. Model artists' acrylic paint films covered with artificial soiling were thus prepared on a canvas support and exposed to a variety of wet cleaning treatments based on aqueous or hydrocarbon solvent systems. This included some with additives such as chelating agents and/or surfactants, and microemulsion systems made specifically for conservation practice. The impact of cleaning (soiling removal) on the paint film surface was examined visually and correlated with results of attenuated total reflection Fourier transform infrared, XPS and near-edge X-ray absorption fine structure analyses – three spectroscopic techniques with increasing surface sensitivity ranging from approximately $-$ 1000, 10 and 5 nm, respectively. Visual analysis established the relative cleaning efficacy of the wet cleaning treatments in line with previous results. X-ray spectroscopy analysis provided significant additional findings, including evidence for (i) surfactant extraction following aqueous swabbing, (ii) modifications to pigment following cleaning and (iii) cleaning system residues.

  2. Stronger multilayer acrylic dielectric elastomer actuators with silicone gel coatings

    NASA Astrophysics Data System (ADS)

    Lau, Gih-Keong; La, Thanh-Giang; Sheng-Wei Foong, Ervin; Shrestha, Milan

    2016-12-01

    Multilayer dielectric elastomer actuators (DEA) perform worst off than single-layer DEAs due to higher susceptibility to electro-thermal breakdown. This paper presents a hot-spot model to predict the electro-thermal breakdown field of DEAs and its dependence on thermal insulation. To inhibit the electrothermal breakdown, silicone gel coating was applied as barrier coating to multilayer acrylic DEA. The gel coating helps suppress the electro-thermally induced puncturing of DEA membrane at the hot spot. As a result, the gel-coated DEAs, in either a single layer or a multilayer stack, can produce 30% more isometric stress change as compared to those none-coated. These gel-coated acrylic DEAs show great potential to make stronger artificial muscles.

  3. Reversible opacification of a hydrophilic acrylic intraocular lens.

    PubMed

    Park, Choul Yong; Chuck, Roy S

    2012-01-01

    A 56-year-old woman with diabetic retinopathy and chronic myelogenous leukemia had phacoemulsification cataract removal and hydrophilic acrylic intraocular lens (IOL) (Akreos MI-60) implantation in both eyes. One month after surgery, significant IOL opacity and severe cystoid macular edema were observed in both eyes. After bilateral intravitreal injection of bevacizumab (Avastin) to control macular edema, central clearing of the IOL opacity was observed in both eyes. Two months after the injection, the IOL opacity had almost disappeared from both eyes. To our knowledge, this is the first case of early postoperative bilateral IOL opacity in a hydrophilic acrylic IOL cleared after anti-vascular endothelial growth factor (VEGF) intravitreal injection. The role of anti-VEGF therapy in clearing IOL opacification requires further investigation.

  4. Wetting properties of saliva substitutes on acrylic resin.

    PubMed

    Aydin, A K; Terzioğlu, H; Ulubayram, K; Hasirci, N

    1997-01-01

    The good wetting of the acrylic resin by saliva substitutes is of clinical importance in xerostomic patients. This study evaluated the wetting properties of different artificial saliva formulations that were mucin-based, carboxymethylcellulose-based, and concentrated ion-based on poly(methyl methacrylate) denture base resin, and compared these properties with natural saliva. The wetting properties of the test materials were examined by contact angle measurements. Ninety-six samples that measured 30 x 30 x 3 mm were examined. The wetting properties of mucin-containing and carboxymethylcellulose-containing substitutes on poly(methyl methacrylate) were significantly better than those of human saliva. Mucin-containing artificial salivas had the best wetting properties on the acrylic resin for the materials tested.

  5. Polymerization of acrylic acid using atmospheric pressure DBD plasma jet

    NASA Astrophysics Data System (ADS)

    Bashir, M.; Bashir, S.

    2016-08-01

    In this paper polymerization of acrylic acid was performed using non thermal atmospheric pressure plasma jet technology. The goal of this study is to deposit organic functional coatings for biomedical applications using a low cost and rapid growth rate plasma jet technique. The monomer solution of acrylic acid was vaporized and then fed into the argon plasma for coating. The discharge was powered using a laboratory made power supply operating with sinusoidal voltage signals at a frequency of 10 kHz. The optical emission spectra were collected in order to get insight into the plasma chemistry during deposition process. The coatings were characterized using Fourier transform infrared spectroscopy, atomic force microscopy and growth rates analysis. A high retention of carboxylic functional groups of the monomer was observed at the surface deposited using this low power technique.

  6. Characterization of methacrylated alginate and acrylic monomers as versatile SAPs.

    PubMed

    Mignon, Arn; Vermeulen, Jolien; Graulus, Geert-Jan; Martins, José; Dubruel, Peter; De Belie, Nele; Van Vlierberghe, Sandra

    2017-07-15

    Superabsorbent polymers (SAPs) based on polysaccharides, especially alginate, could offer a valuable solution in a plethora of applications going from drug delivery to self-healing concrete. This has already been proven with both calcium alginate and methacrylated alginate combined with acrylic acid. In this manuscript, the effect of varying the degree of methacrylation and use of a combination of acrylic acid and acrylamide is investigated to explore the effects on the relevant SAP characteristics. The materials showed high gel fractions and a strong swelling capacity up to 630gwater/gSAP, especially for superabsorbent polymers with a low degree of substitution. The SAPs also showed only a limited hydrolysis in aqueous and cement filtrate solutions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Anterior Knee Pain (Chondromalacia Patellae).

    ERIC Educational Resources Information Center

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  8. Anterior Knee Pain (Chondromalacia Patellae).

    ERIC Educational Resources Information Center

    Garrick, James G.

    1989-01-01

    This article presents a pragmatic approach to the definition, diagnosis, and management of anterior knee pain. Symptoms and treatment are described. Emphasis is on active involvement of the patient in the rehabilitation exercise program. (IAH)

  9. Competing edge networks

    NASA Astrophysics Data System (ADS)

    Parsons, Mark; Grindrod, Peter

    2012-06-01

    We introduce a model for a pair of nonlinear evolving networks, defined over a common set of vertices, subject to edgewise competition. Each network may grow new edges spontaneously or through triad closure. Both networks inhibit the other's growth and encourage the other's demise. These nonlinear stochastic competition equations yield to a mean field analysis resulting in a nonlinear deterministic system. There may be multiple equilibria; and bifurcations of different types are shown to occur within a reduced parameter space. This situation models competitive communication networks such as BlackBerry Messenger displacing SMS; or instant messaging displacing emails.

  10. Acrylic strengthened casts for removable partial denture for occlusion equilibration.

    PubMed

    Oh, Won-Suk; Saglik, Berna

    2011-09-01

    A removable partial denture (RPD) remount cast must resist wear or breakage, present a rigid surface, and ensure a solid support for an accurate equilibration of the occlusion for a RPD. This article describes a procedure of processing a thin layer of tooth colored acrylic resin over the dental plaster to present wear- and fracture-resistant incisal/occlusal surfaces without involving a third material.

  11. Corrosion inhibition of reinforcing steel by using acrylic latex

    SciTech Connect

    Wang, S.X.; Lin, W.W.; Ceng, S.A.; Zhang, J.Q.

    1998-05-01

    Acrylic latex was introduced into steel-reinforcing steel concrete as concrete admixtures or rebar coatings in order to prevent corrosion of steel reinforcements. The results showed that applying the latex by both methods took effect in different ways, while the latter was more noticeable. The corrosion prevention mechanism and the surface state of the steel rebar were also explored, based on which suggestions for enhancing the corrosion-resistant ability were made.

  12. Superselective Embolization in Posttraumatic Priapism with Glubran 2 Acrylic Glue

    SciTech Connect

    Gandini, Roberto; Spinelli, Alessio; Konda, Daniel Reale, Carlo Andrea; Fabiano, Sebastiano; Pipitone, Vincenzo; Simonetti, Giovanni

    2004-09-15

    Two patients with posttraumatic priapism underwent transcatheter embolization using microcoils, resulting in temporary penile detumescence and an apparent resolution of the artero-venous fistula. In both cases, priapism recurred 24 hours after the procedure and was successfully treated through selective transcatheter embolization of the nidus using acrylic glue (Glubran 2). The patients showed complete recovery of sexual activity within 30 days from the procedure and persistent exclusion of the artero-venous fistula after a 12-month follow-up.

  13. Acrylic microspheres-based optosensor for visual detection of nitrite.

    PubMed

    Noor, Nur Syarmim Mohamed; Tan, Ling Ling; Heng, Lee Yook; Chong, Kwok Feng; Tajuddin, Saiful Nizam

    2016-09-15

    A new optosensor for visual quantitation of nitrite (NO2(-)) ion has been fabricated by physically immobilizing Safranine O (SO) reagent onto a self-adhesive poly(n-butyl acrylate) [poly(nBA)] microspheres matrix, which was synthesized via facile microemulsion UV lithography technique. Evaluation and optimization of the optical NO2(-) ion sensor was performed with a fiber optic reflectance spectrophotometer. Scanning electron micrograph showed well-shaped and smooth spherical morphology of the poly(nBA) microspheres with a narrow particles size distribution from 0.6 μm up to 1.8 μm. The uniform size distribution of the acrylic microspheres promoted homogeneity of the immobilized SO reagent molecules on the microspheres' surfaces, thereby enhanced the sensing response reproducibility (<5% RSD) with a linear range obtained from 10 to 100 ppm NO2(-) ion. The micro-sized acrylic immobilization matrix demonstrated no significant barrier for diffusion of reactant and product, and served as a good solid state ion transport medium for reflectometric nitrite determination in food samples.

  14. Amphiphilic photosensitive dextran-g-poly(o-nitrobenzyl acrylate) glycopolymers.

    PubMed

    Soliman, Soliman Mehawed Abdellatif; Colombeau, Ludovic; Nouvel, Cécile; Babin, Jérôme; Six, Jean-Luc

    2016-01-20

    Among all photosensitive monomers reported in the literature, o-nitrobenzyl acrylate (NBA) was selected in this present study. Two strategies were compared to produce azido-terminated poly(o-nitrobenzyl acrylate) (PNBA) using controlled Single Electron Transfer-Living Radical Polymerization (SET-LRP). In a parallel way, dextran (Dex) was modified by the introduction of several alkynyl-terminated hydrophobic chains. Finally, an Huisgen-type Copper (I)-catalyzed Azide-Alkyne Cycloaddition (CuAAC) click-chemistry was carried out to produce amphiphilic Dex-g-PNBA glycopolymers with different number and length of PNBA grafts. 2D DOSY (1)H NMR was used to prove the formation of such glycopolymers. Preliminary study on Dex-g-PNBA self-assembly was done by measuring the critical water content (CWC) above which Dex-g-PNBA started to auto-organize themselves to produce nano-objects. Finally, under UV irradiation, PNBA grafts turn into poly(acrylic acid) ones giving light-sensitive properties to such amphiphilic Dex-g-PNBA. Such properties were evaluated and compared with those of PNBA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Epoxy-acrylic core-shell particles by seeded emulsion polymerization.

    PubMed

    Chen, Liang; Hong, Liang; Lin, Jui-Ching; Meyers, Greg; Harris, Joseph; Radler, Michael

    2016-07-01

    We developed a novel method for synthesizing epoxy-acrylic hybrid latexes. We first prepared an aqueous dispersion of high molecular weight solid epoxy prepolymers using a mechanical dispersion process at elevated temperatures, and we subsequently used the epoxy dispersion as a seed in the emulsion polymerization of acrylic monomers comprising methyl methacrylate (MMA) and methacrylic acid (MAA). Advanced analytical techniques, such as scanning transmission X-ray microscopy (STXM) and peak force tapping atomic force microscopy (PFT-AFM), have elucidated a unique core-shell morphology of the epoxy-acrylic hybrid particles. Moreover, the formation of the core-shell morphology in the seeded emulsion polymerization process is primarily attributed to kinetic trapping of the acrylic phase at the exterior of the epoxy particles. By this new method, we are able to design the epoxy and acrylic polymers in two separate steps, and we can potentially synthesize epoxy-acrylic hybrid latexes with a broad range of compositions.

  16. Research of morphology structure and properties of bamboo charcoal acrylic fiber

    NASA Astrophysics Data System (ADS)

    Zhang, Yongjiu; Feng, Aifen

    2015-07-01

    In order to understand the properties of bamboo charcoal acrylic fiber, the tensile properties, friction properties and hygroscopicity of it, the bamboo charcoal acrylic fiber and the ordinary acrylic fiber were tested, compared and analyzed. The burning behaviors of the two kinds of fibers were observed by burning test, and their cross-sectional and longitudinal morphology was observed with scanning electron microscope (SEM). The SEM pictures showed that there are the uneven sizes of microspores on the surface of bamboo charcoal acrylic fiber and in it. It was found that the friction coefficients of the bamboo charcoal acrylic fiber are smaller and its tensile and moisture absorption are better than those of the ordinary acrylic fiber. However, there are no obvious differences of the burning behaviors between the two fibers.

  17. Allergic contact dermatitis due to urethane acrylate in ultraviolet cured inks.

    PubMed Central

    Nethercott, J R; Jakubovic, H R; Pilger, C; Smith, J W

    1983-01-01

    Seven workers exposed to ultraviolet printing inks developed contact dermatitis. Six cases were allergic and one irritant. A urethane acrylate resin accounted for five cases of sensitisation, one of which was also sensitive to pentaerythritol triacrylate and another also to an epoxy acrylate resin. One instance of allergy to trimethylpropane triacrylate accounted for the sixth case of contact dermatitis in this group of workers. An irritant reaction is presumed to account for the dermatitis in the individual not proved to have cutaneous allergy by patch tests. In this instance trimethylpropane triacrylate was thought to be the most likely irritating agent. Laboratory investigation proved urethane acrylate to be an allergen. The results of investigations of the sensitisation potentials of urethane acrylate, methylmethacrylate, epoxy acrylate resins, toluene-2,4-diisocyanate, and other multifunctional acrylic monomers in the albino guinea pig are presented. The interpretation of such predictive tests is discussed. Images PMID:6223656

  18. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    NASA Astrophysics Data System (ADS)

    Tajau, Rida; Ibrahim, Mohammad Izzat; Yunus, Nurulhuda Mohd; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik

    2014-02-01

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough.

  19. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    SciTech Connect

    Tajau, Rida; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik; Ibrahim, Mohammad Izzat; Yunus, Nurulhuda Mohd

    2014-02-12

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough.

  20. Apparent fracture toughness of acrylic bone cement: effect of test specimen configuration and sterilization method.

    PubMed

    Lewis, G

    1999-01-01

    The plane strain fracture toughness of Palacos R bone cement was determined using linear elastic fracture mechanics (LEFM) principles and three different test specimen configurations: single edge notched three-point (SENB), rectangular compact tension (RCT), and chevron notched short rod (CNSR). Another aspect of the study was an investigation of the effect of three methods used to sterilize the powder constituents of the cement-none, gamma irradiation and ethylene oxide--on the fracture toughness of the fully polymerized material. A detailed justification is provided for using LEFM. The fracture toughness results obtained using the CNSR specimens were, on average, 14 and 16% higher than those obtained using the SENB and RCT types, respectively. These differences are accounted for in terms of differences in four aspects of these specimen configuration (namely, residual stress effects, loading rate, material inhomogeneity, and the nature of the test). For a given specimen configuration, gamma irradiation produced a statistically significant decrease in fracture toughness which, it is suggested, is due to the concomitant depreciation in molecular weight. For a given cement type, there is no statistically significant difference in fracture toughness results obtained using SENB and RCT specimens. It is thus suggested that either of these configurations can be used to determine the fracture toughness of acrylic bone cement.

  1. Production and characterization of cut resistant acrylic/copolyaramid fibers via bicomponent wet spinning

    NASA Astrophysics Data System (ADS)

    Hipp, Stephen James

    A composite fiber system consisting of a sheath core bicomponent polymer fiber loaded with hard ceramic particles was developed and characterized for use in cut protective clothing. The core component was comprised of a copolyaramid in order to provide high base cut resistance. An acrylic-copolyaramid polymer blend was used for the sheath component to improve processability and provide potential benefits such as dyeability. Lastly, aluminum oxide particles were incorporated into the fiber core to deflect and deform the cutting edge, further improving cut resistance. A series of designed experiments was used to explore the effects of the wet spinning and heat treatment processes on the structure and properties of the bicomponent fiber. Cut strength of the as-spun fibers was highest when the coagulation rate was slow, promoting the formation of a dense, macrovoid free fiber structure. Upon drawing, fibrillar domains developed within the fiber, further improving cut performance. Cut strength was greatly improved by the heat treatment process despite the fibers becoming highly anisotropic. Addition of the hard particle fillers to the bicomponent fibers showed a decrease in cut strength at the fiber level but nearly doubled the cut strength of resulting fabrics. Finally, the processability of the particle loaded bicomponent fibers was evaluated.

  2. Comparison between an Acrylic Splint Herbst and an Acrylic Splint Miniscrew-Herbst for Mandibular Incisors Proclination Control

    PubMed Central

    Manni, Antonio; Pasini, Marco; Nuzzo, Claudio; Grassi, Felice Roberto

    2014-01-01

    Aim. The aim of this study is to compare dental and skeletal effects produced by an acrylic splint Herbst with and without skeletal anchorage for correction of dental class II malocclusion. Methods. The test group was formed by 14 patients that were treated with an acrylic splint miniscrew-Herbst; miniscrews were placed between mandibular second premolars and first molars; controls also consisted of 14 subjects that were treated with an acrylic splint Herbst and no miniscrews. Cephalometric measurements before and after Herbst treatment were compared. The value of α for significance was set at 0.05. Results. All subjects from both groups were successfully treated to a bilateral Class I relationship; mean treatment time was 8,1 months in the test group and 7.8 in the controls. Several variables did not have a statistical significant difference between the two groups. Some of the variables, instead, presented a significant difference such as incisor flaring, mandibular bone base position, and skeletal discrepancy. Conclusions. This study showed that the Herbst appliance associated to miniscrews allowed a better control of the incisor flaring with a greater mandibular skeletal effect. PMID:24963293

  3. N-Butyl acrylate polymer composition for solar cell encapsulation and method

    NASA Technical Reports Server (NTRS)

    Gupta, Amitava (Inventor); Ingham, John D. (Inventor); Yavrouian, Andre H. (Inventor)

    1983-01-01

    A polymer syrup for encapsulating solar cell assemblies. The syrup includes uncrosslinked poly(n-butyl)acrylate dissolved in n-butyl acrylate monomer. Preparation of the poly(n-butyl)acrylate and preparation of the polymer syrup is disclosed. Methods for applying the polymer syrup to solar cell assemblies as an encapsulating pottant are described. Also included is a method for solar cell construction utilizing the polymer syrup as a dual purpose adhesive and encapsulating material.

  4. Influence of Zwitterions on Thermomechanical Properties and Morphology of Acrylic Copolymers: Implications for Electroactive Applications

    DTIC Science & Technology

    2011-09-30

    properties of ethyl acrylate and n-butyl acrylate ( nBA )-based sulfobetaine-containing copolymers.10,11 They found that the incorporation of...ammonio]-1-propanesulfonate (SBMA), a zwitterionic mono- mer. Copolymerization of both charge-containing monomers with nBA elucidates the influence of...3-[[2-(methacryloyloxy)ethyl]- (dimethyl)ammonio]-1-propanesulfonate (SBMA), was generously provided by Raschig GmbH. n-Butyl acrylate ( nBA , Alfa

  5. Are shrubland birds edge specialists?

    PubMed

    Schlossberg, Scott; King, David I

    2008-09-01

    In studies of forest fragmentation, birds of scrubby, early-successional habitats are considered edge specialists. Because these birds are assumed to thrive in fragmented, edge-dominated areas, their landscape ecology has received little attention from ecologists. With populations of shrubland birds declining throughout the eastern United States, the question of whether or not these birds really prefer edge habitats has important conservation implications. We used a meta-analysis to test how edges affect the abundance of shrubland birds in early-successional habitats. We analyzed data for 17 species from seven studies that compared the abundances of birds in the interiors and edges of regenerating clearcuts surrounded by mature forest. The meta-analysis clearly showed that shrubland birds avoid edges. All 17 species tested had higher abundances in patch centers than along edges, and edge effects were significant for 8 of 17 species. The key implication of this result is that small or irregular patches, dominated by edge, are unlikely to provide suitable habitat for shrubland birds. Thus, management for these declining species should involve providing large patches and minimizing edges. These findings demonstrate the importance of testing widely accepted ecological classifications and the need to view landscape ecology from the perspective of non-forest wildlife.

  6. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials.

    PubMed

    Heidari, Bijan; Firouz, Farnaz; Izadi, Alireza; Ahmadvand, Shahbaz; Radan, Pegah

    2015-05-01

    Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a common clinical occurrence, which often develops in the midline of the denture base. This study aimed to evaluate the efficacy of cold-cure and heat-cure acrylic resins, reinforced with glass fibers, polyethylene fibers, and metal wire for denture base repair. Ninety specimens were prepared and allocated to nine groups. Ten specimens were considered as controls, and 80 were divided into 8 experimental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was divided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were subjected to a 3-point bending test, and the flexural strength was calculated. The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement. Repairing denture base with heat cure acrylic resin, reinforced with glass fibers increases the flexural strength of denture base.

  7. (Meth)Acrylate Occupational Contact Dermatitis in Nail Salon Workers: A Case Series.

    PubMed

    DeKoven, Samuel; DeKoven, Joel; Holness, D Linn

    Recently, many cases of acrylate-associated allergic contact dermatitis have appeared among nail salon workers. Common acrylate-containing products in nail salons include traditional nail polish, ultraviolet-cured shellac nail polish, ultraviolet-cured gel nails, and press-on acrylic nails. Nail salon technicians seen in the occupational medicine clinic in 2015 and 2016 were identified, and their patch test results and clinical features were summarized. Patch testing was done with the Chemotechnique (Meth)Acrylate nail series, and either the North American Standard series or the North American Contact Dermatitis Group screening series. Six patients were identified, all women, ages 38 to 58. Common presentations included erythematous dermatitis of the dorsa of the hands, palms, and forearms and fissures on the fingertips. Less common sites of eruptions included the periorbital region, cheeks, posterior ears, neck, sacral area, lateral thighs, and dorsa of the feet. All patients reacted to hydroxyethyl methacrylate, and 5 patients reacted to ethyl acrylate. Each patient also reacted to (meth)acrylates that are not found on either standard series, including ethyleneglycol dimethacrylate, 2-hydroxypropyl methacrylate, and 2-hydroxyethyl acrylate. The authors report 6 cases of allergic contact dermatitis to acrylates in nail technicians seen over the past year, representing a new trend in their clinic. These cases are reflective of a growing trend of nail technicians with allergic contact dermatitis associated with occupational (meth)acrylate exposure. Efforts to improve prevention are needed.

  8. Screening for acrylate/methacrylate allergy in the baseline series: our experience in Sweden and Singapore.

    PubMed

    Goon, Anthony Teik-Jin; Bruze, Magnus; Zimerson, Erik; Goh, Chee-Leok; Soo-Quee Koh, David; Isaksson, Marléne

    2008-11-01

    No studies to specifically determine the prevalence of contact allergy to acrylates/methacrylates in patch tested populations have been published. To determine the prevalence of acrylate/methacrylate allergy in all patients tested to the baseline patch test series. Five acrylate/methacrylate allergens (2-hydroxyethyl methacrylate, methyl methacrylate, ethylene glycol dimethacrylate, triethylene glycol diacrylate, and 2-hydroxypropyl acrylate) were included in the baseline series for at least 2 years in Malmö and Singapore. Thirty-eight patients in total had reacted to acrylate/methacrylate allergens in the baseline series during the study period in both populations. In Malmö, there were 26 (1.4%) patients with positive patch tests to acrylate/methacrylate allergens, 14 of whom had relevant reactions. In Singapore, there were 12 (1.0%) patients with positive patch tests to acrylate/methacrylate allergens, but only 1 had relevant reactions. If we had not added acrylate/methacrylate allergens to the baseline series, we would not have patch tested 13/26 (50%) of the positive reactors in Malmö and 11/12 (92%) of the positive reactors in Singapore. The overall proportion of missed positive reactors would have been 24/38 (63%). The prevalence of acrylate/methacrylate allergy in our patch tested dermatitis populations is 1.4% in Malmö and 1.0% in Singapore.

  9. Edge remap for solids

    SciTech Connect

    Kamm, James R.; Love, Edward; Robinson, Allen C.; Young, Joseph G.; Ridzal, Denis

    2013-12-01

    We review the edge element formulation for describing the kinematics of hyperelastic solids. This approach is used to frame the problem of remapping the inverse deformation gradient for Arbitrary Lagrangian-Eulerian (ALE) simulations of solid dynamics. For hyperelastic materials, the stress state is completely determined by the deformation gradient, so remapping this quantity effectively updates the stress state of the material. A method, inspired by the constrained transport remap in electromagnetics, is reviewed, according to which the zero-curl constraint on the inverse deformation gradient is implicitly satisfied. Open issues related to the accuracy of this approach are identified. An optimization-based approach is implemented to enforce positivity of the determinant of the deformation gradient. The efficacy of this approach is illustrated with numerical examples.

  10. On the Edge

    NASA Image and Video Library

    2015-02-04

    In today's image, Mercury's horizon cuts a striking edge against the stark blackness of space. On the right, sunlight harshly brings the landscape into relief while on the left, the surface is shrouded in the darkness of night. This image was acquired as part of MDIS's limb imaging campaign. Once per week, MDIS captures images of Mercury's limb, with an emphasis on imaging the southern hemisphere limb. These limb images provide information about Mercury's shape and complement measurements of topography made by the Mercury Laser Altimeter (MLA) of Mercury's northern hemisphere. Date acquired: January 20, 2015 Image Mission Elapsed Time (MET): 64084239 Image ID: 7831084 Instrument: Wide Angle Camera (WAC) of the Mercury Dual Imaging System (MDIS) WAC filter: 7 (748 nanometers) Center Latitude: -54.45° Center Longitude: 90.52° E Center Resolution: 401 meters/pixel http://photojournal.jpl.nasa.gov/catalog/PIA19192

  11. Results of cataract surgery and plasma ablation posterior capsulotomy in anterior persistent hyperplastic primary vitreous.

    PubMed

    Sinha, Rajesh; Bali, Shveta Jindal; Kumar, Chandrashekhar; Shekhar, Himanshu; Sharma, Namrata; Titiyal, Jeewan S; Vajpayee, Rasik B

    2013-01-01

    To report the feasibility and outcome of lens aspiration, and Fugo blade-assisted capsulotomy and anterior vitrectomy in eyes with anterior persistent hyperplastic primary vitreous (PHPV). In this case series, 10 eyes of 10 patients with anterior PHPV underwent lens aspiration. The vascularized posterior capsule was cut with a Fugo blade (plasma knife) and removed with a vitrector. A foldable posterior chamber intraocular lens (IOL) was implanted in eight eyes and the outcomes were evaluated. The mean age of patients was 16.8 ± 6.37 months (range: 5 to 28 months). The surgery was completed successfully in all eyes. There were no cases of intraocular hemorrhage intraoperatively. Foldable acrylic IOL was implanted in the bag in 3 eyes and in the sulcus in 5 eyes. Two eyes were microphthalmic and did no undergo IOL implantation (aphakic). None of the eyes had a significant reaction or elevated intraocular pressure postoperatively. The follow-up ranged from 4 to 21 months. All the pseudophakic eyes achieved a best corrected visual acuity of ≥20/200 with 50% (4/8) of these eyes with ≥20/60 vision. Lens aspiration followed by posterior capsulotomy with Fugo blade-assisted plasma ablation is a feasible technique for performing successful lens surgery in cases with florid anterior PHPV.

  12. Edge phonons in black phosphorus

    PubMed Central

    Ribeiro, H. B.; Villegas, C. E. P.; Bahamon, D. A.; Muraca, D.; Castro Neto, A. H.; de Souza, E. A. T.; Rocha, A. R.; Pimenta, M. A.; de Matos, C. J. S.

    2016-01-01

    Black phosphorus has recently emerged as a new layered crystal that, due to its peculiar and anisotropic crystalline and electronic band structures, may have important applications in electronics, optoelectronics and photonics. Despite the fact that the edges of layered crystals host a range of singular properties whose characterization and exploitation are of utmost importance for device development, the edges of black phosphorus remain poorly characterized. In this work, the atomic structure and behaviour of phonons near different black phosphorus edges are experimentally and theoretically studied using Raman spectroscopy and density functional theory calculations. Polarized Raman results show the appearance of new modes at the edges of the sample, and their spectra depend on the atomic structure of the edges (zigzag or armchair). Theoretical simulations confirm that the new modes are due to edge phonon states that are forbidden in the bulk, and originated from the lattice termination rearrangements. PMID:27412813

  13. Edge phonons in black phosphorus

    NASA Astrophysics Data System (ADS)

    Ribeiro, H. B.; Villegas, C. E. P.; Bahamon, D. A.; Muraca, D.; Castro Neto, A. H.; de Souza, E. A. T.; Rocha, A. R.; Pimenta, M. A.; de Matos, C. J. S.

    2016-07-01

    Black phosphorus has recently emerged as a new layered crystal that, due to its peculiar and anisotropic crystalline and electronic band structures, may have important applications in electronics, optoelectronics and photonics. Despite the fact that the edges of layered crystals host a range of singular properties whose characterization and exploitation are of utmost importance for device development, the edges of black phosphorus remain poorly characterized. In this work, the atomic structure and behaviour of phonons near different black phosphorus edges are experimentally and theoretically studied using Raman spectroscopy and density functional theory calculations. Polarized Raman results show the appearance of new modes at the edges of the sample, and their spectra depend on the atomic structure of the edges (zigzag or armchair). Theoretical simulations confirm that the new modes are due to edge phonon states that are forbidden in the bulk, and originated from the lattice termination rearrangements.

  14. Anterior placentation as a risk factor for massive hemorrhage during cesarean section in patients with placenta previa.

    PubMed

    Baba, Yosuke; Matsubara, Shigeki; Ohkuchi, Akihide; Usui, Rie; Kuwata, Tomoyuki; Suzuki, Hirotada; Takahashi, Hironori; Suzuki, Mitsuaki

    2014-05-01

    In placenta previa (PP), anterior placentation, compared with posterior placentation, is reported to more frequently cause massive hemorrhage during cesarean section (CS). Whether this is due to the high incidence of placenta accreta, previous CS, or a transplacental approach in anterior placenta is unclear. We attempted to clarify this issue. We retrospectively analyzed the relation between the bleeding amount during CS for PP and various factors that may cause massive hemorrhage (>2400 mL) (n = 205) in a tertiary center. If the preoperatively ultrasound-measured distance from the internal cervical ostium to the placental edge was longer in the uterine anterior wall than in the posterior wall, we defined it as anterior previa, and vice versa. Patients with accreta, previous CS, total previa, and anterior placentation bled significantly more than their counterparts. Multivariate logistic regression analysis showed that accreta (odds ratio [OR] 12.6), previous CS (OR 4.7), total previa (OR 4.1), and anterior placentation (OR 3.5) were independent risk factors of massive hemorrhage. Anterior placentation, namely, the placenta with a longer os-placental edge distance in the anterior wall than in the posterior wall, was a risk of massive hemorrhage during CS for PP. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  15. Enhanced lung cancer detection in temporal subtraction chest radiography using directional edge filtering techniques

    NASA Astrophysics Data System (ADS)

    Zhao, Hui; Lo, Shih-Chung B.; Freedman, Matthew T.; Wang, Yue J.

    2002-05-01

    We have developed a series of directional edge enhancement and edge extraction methods that can accurately segment posterior and anterior ribs in chest radiography. These methods can also separate the lower and upper edges of ribs. The edges were first enhanced by two sets of proximate parabola curve models for left and right sides of the image. We used a directional edge filtering technique to remove low signals and noises on the edge enhanced image in the multiresolution domain. Finally, we employed a rib curve projection and reasoning method to reconstruct the rib edges and remove false edges for the upper and lower bound of the rib edges independently. A two-step registration, corresponding to global and local matching, is applied for current and prior images assisted by their corresponding edge images. The subtraction images were then processed by a rule-based CAD system. The FROC results were compared to that obtained by the original image using a CAD system consisting of rule-based and convolution neural network processing. The majority of lung cancer in temporal subtraction images were lit-up. The FROC results were significantly improved using the subtraction image with the rule-based CAD.

  16. Distribution of the microelastic properties within the human anterior mitral leaflet.

    PubMed

    Jensen, Anne Skakkebaek; Baandrup, Ulrik; Hasenkam, J Michael; Kundu, Tribikram; Jørgensen, Claus Schiøtt

    2006-12-01

    Knowledge of the biomechanical properties of the mitral valve leaflets and their relation to histologic structure is of importance for understanding the leaflet movement characteristics under normal and pathologic conditions, but such knowledge is not yet available. The aim of this study was to determine biomechanical properties of the human anterior mitral leaflet on a microscopic scale. We used scanning acoustic microscopy (SAM) to examine the human anterior mitral leaflet. Sections of fixed human anterior mitral leaflet tissue were obtained from postmortem human anterior mitral leaflets (n = 5). We measured the speed of sound (nu(L)) in each histologic layer in three regions-of-interest (ROIs): these were at the annular edge, at the valve midpoint and close to the free edge. nu(L) varied in the three histologic layers (p < 0.01). It was higher in the fibrous layer (1.76 km/s) compared with the atrial layer (1.75 km/s) and ventricular layer (1.73 km/s). Also, nu(L) differed between positions along the length of the annulus-free edge line (p < 0.01), showing a decline from the annular edge (1.76 km/s) to the free edge (1.73 km/s), both as a whole and also within the atrial and the fibrous layer. These results demonstrate that the fibrous layer is stiffer than the atrial and ventricular layer and that the leaflet as a whole and within the atrial and the fibrous layer is stiffer at the annulus part in comparison with those near the free edge. (E-mail: ).

  17. The Facilitator's Edge: Group Sessions for Edge-ucators.

    ERIC Educational Resources Information Center

    Handcock, Helen

    The Facilitator's Edge is a workshop series based on the life/work messages of The Edge magazine. The workshops are deigned to help educators, youth workers, and their career practitioners facilitate conscious career building. This manual consists of five group sessions, each focusing on a different career-building theme. "Megatrends and…

  18. The Facilitator's Edge: Group Sessions for Edge-ucators.

    ERIC Educational Resources Information Center

    Handcock, Helen

    The Facilitator's Edge is a workshop series based on the life/work messages of The Edge magazine. The workshops are deigned to help educators, youth workers, and their career practitioners facilitate conscious career building. This manual consists of five group sessions, each focusing on a different career-building theme. "Megatrends and…

  19. Preprosthetic movement of anterior teeth.

    PubMed

    Melsen, B

    1982-05-01

    Preprosthetic movement of anterior teeth is often performed on patients with missing anterior teeth, providing a better basis for subsequent bridgework. This can often be achieved by horizontal tooth movements of a tipping or translatory art whilst other patients present problems of a vertical nature with a deep overbite inconsistent with a healthy periodontal status. Intrusive tooth movements are needed as changes in facial height are not tolerated. The importance of understanding the biological basis for tooth movements in the planning of the biomechanics is stressed. Forces should be monitored according to the amount of general and local bone loss.

  20. Edge-edge interactions in stacked graphene nanoplatelets

    SciTech Connect

    Cruz Silva, Eduardo; Terrones Maldonado, Humberto; Terrones Maldonado, Mauricio; Jia, Xiaoting; Sumpter, Bobby G; Dresselhaus, M; Meunier, V.

    2013-01-01

    High-resolution transmission electron microscopy (HRTEM) studies show the dynamics of small graphene platelets on larger graphene layers. The platelets move nearly freely to eventually lock in at well-defined positions close to the edges of the larger underlying graphene sheet. While such movement is driven by a shallow potential energy surface described by an interplane interaction, the lock-in position occurs by via edge-edge interactions of the platelet and the graphene surface located underneath. Here we quantitatively study this behavior using van der Waals density functional calculations. Local interactions at the open edges are found to dictate stacking configurations that are different from Bernal (AB) stacking. These stacking configurations are known to be otherwise absent in edge-free two-dimensional (2D) graphene. The results explain the experimentally observed platelet dynamics and provide a detailed account of the new electronic properties of these combined systems.

  1. Giant edge state splitting at atomically precise graphene zigzag edges

    PubMed Central

    Wang, Shiyong; Talirz, Leopold; Pignedoli, Carlo A.; Feng, Xinliang; Müllen, Klaus; Fasel, Roman; Ruffieux, Pascal

    2016-01-01

    Zigzag edges of graphene nanostructures host localized electronic states that are predicted to be spin-polarized. However, these edge states are highly susceptible to edge roughness and interaction with a supporting substrate, complicating the study of their intrinsic electronic and magnetic structure. Here, we focus on atomically precise graphene nanoribbons whose two short zigzag edges host exactly one localized electron each. Using the tip of a scanning tunnelling microscope, the graphene nanoribbons are transferred from the metallic growth substrate onto insulating islands of NaCl in order to decouple their electronic structure from the metal. The absence of charge transfer and hybridization with the substrate is confirmed by scanning tunnelling spectroscopy, which reveals a pair of occupied/unoccupied edge states. Their large energy splitting of 1.9 eV is in accordance with ab initio many-body perturbation theory calculations and reflects the dominant role of electron–electron interactions in these localized states. PMID:27181701

  2. Reactivity of Monovinyl (Meth)Acrylates Containing Cyclic Carbonates.

    PubMed

    Berchtold, Kathryn A; Nie, Jun; Stansbury, Jeffrey W; Bowman, Christopher N

    2008-12-09

    The tremendous diversity of materials properties available with polymers is due in large part to the ability to design structures from the monomeric state. The ease of use of comonomer mixtures only expands this versatility. While final polymer properties are obviously important in the selection or development of a material for a given purpose, for a number of applications, such as optical fiber coatings, photolithography and microelectronics, the additional requirement of a very rapid polymerization process may be equally critical. A class of unusually reactive mono-(meth)acrylate monomers bearing secondary functionality that includes carbonates, carbamates and oxazolidones, has been demonstrated but not fully explained. Here, the influence of an integral cyclic carbonate functional group on (meth)acrylate photopolymerization kinetics is examined in detail with respect to monomers with a wide variety of alternative secondary functionality structure as well as in comparison to conventional mono- and di-(meth)acrylates. The kinetic results from full cure studies of several cyclic carbonate-containing monomers clearly highlight specific structural variations that effectively promote monomer reactivity. Copolymerizations with tetrahydrofurfuryl methacrylate reflect similar dramatic kinetic effects associated with the novel monomers while partial cure homopolymerization studies reveal exceptional dark cure behavior linked to observations of uncommonly low ratios of termination to propagation rates throughout the conversion profile. Temperature effects on reaction kinetics, including both reaction rate and the individual kinetic parameters, as well as the temperature dependence of hydrogen bonding interactions specifically involving the secondary functional groups are probed as a means to understand better the fundamentally interesting and practically important behavior of these monomers.

  3. Anomerization of Acrylated Glucose During Traveling Wave Ion Mobility Spectrometry

    NASA Astrophysics Data System (ADS)

    Chendo, Christophe; Moreira, Guillaume; Tintaru, Aura; Posocco, Paola; Laurini, Erik; Lefay, Catherine; Gigmes, Didier; Viel, Stéphane; Pricl, Sabrina; Charles, Laurence

    2015-09-01

    Anomerization of simple sugars in the liquid phase is known as an acid- and base-catalyzed process, which highly depends on solvent polarity. This reaction is reported here to occur in the gas phase, during traveling wave ion mobility spectrometry (TWIMS) experiments aimed at separating α- and β-anomers of penta-acrylated glucose generated as ammonium adducts in electrospray ionization. This compound was available in two samples prepared from glucose dissolved in solvents of different polarity, namely tetrahydrofuran (THF) and N,N-dimethylacetamide (DMAC), and analyzed by electrospray tandem mass spectrometry (ESI-MS/MS) as well as traveling wave ion mobility (ESI-TWIMS-MS). In MS/MS, an anchimerically-assisted process was found to be unique to the electrosprayed α-anomer, and was only observed for the THF sample. In ESI-TWIMS-MS, a signal was measured at the drift time expected for the α-anomer for both the THF and DMAC samples, in apparent contradiction to the MS/MS results, which indicated that the α-anomer was not present in the DMAC sample. However, MS/MS experiments performed after TWIMS separation revealed that ammonium adducts of the α-anomer produced from each sample, although exhibiting the same collision cross section, were clearly different. Indeed, while the α-anomer actually present in the THF sample was electrosprayed with the ammonium adducted at the C2 acrylate, its homologue only observed when the DMAC sample was subjected to TWIMS hold the adducted ammonium at the C1 acrylate. These findings were explained by a β/α inter-conversion upon injection in the TWIMS cell, as supported by theoretical calculation and dynamic molecular modeling.

  4. Flexural properties of glass fibre reinforced acrylic resin polymers.

    PubMed

    Tacir, I H; Kama, J D; Zortuk, M; Eskimez, S

    2006-03-01

    In recent years, glass fibres have been used to strengthen denture base resins. A major difficulty in using reinforcing fibres with multiphase acrylic resins, such as powder liquid resins, is inadequate impregnation of the fibres with the resin. This investigation examined the reinforcing effect of glass fibres on the fracture resistance and flexural strength of acrylic denture base resins. Eighty identical specimens were formed in specially designed moulds in accordance with the manufacturer's recommendations. The four experimental groups were prepared and these consisted of conventional acrylic resin and the same resin reinforced with glass fibres. Ten specimens were fabricated in a standardized fashion for each experimental group. Flexural strength was tested using a 3-point universal testing machine. In this study, statistically significant differences were found in the flexural strength of the specimens (P < 0.05). The injection-moulded, fibre-reinforced group had significantly lower flexural strength than the injection-moulded group (P < 0.001), strength than the microwave-moulded, fibre-reinforced group (P < 0.001), and the microwave-moulded, fibre-reinforced group had lower flexural strength than the microwave-moulded group. The fracture resistance was significantly higher in the injection-moulded, fibre-reinforced group than in the injection-moulded group (P < 0.05), and the fracture resistance was significantly higher in the microwave-moulded, fibre-reinforced group than in the microwave-moulded group. Within the limitations of this study, the flexural strength of heat-polymerized PMMA denture resin was improved after reinforcement with glass fibres. It may be possible to apply these results to distal extension partial and complete denture bases.

  5. Development of Electrically Conductive Transparent Coatings for Acrylic Plastic

    DTIC Science & Technology

    1952-12-01

    and methyl methacrylate monomer (I mole) in cyciohexanone (Z moles) vw’th benzoyl peroxide catalyst (0, Z% of total weight). The mix- ture was refluxed... methacrylic acid- methyl methaerylate copolymer re•I. The composite material, i. e., the acrylic and applied coating, retains essentially all the original...0.001" to 0.002" when rolled on and of less than 0.001" when sprayed on. The ability of the methacrylic acid- methyl methacrylate copolymer to cover the

  6. Depositing highly adhesive optical thin films on acrylic substrates.

    PubMed

    Takahashi, Tomoaki; Harada, Toshinori; Murotani, Hiroshi; Matumoto, Shigeharu

    2014-02-01

    Optical thin films are used to control the reflectance and transmittance of optical components. However, conventional deposition technologies applicable to organic (plastic) substrates typically result in weak adhesion. We overcame this problem by using vacuum deposition in combination with sputtering to directly deposit a SiO2 optical thin film onto an acrylic resin substrate. We observed neither yellowing nor deformation. The hardness of the film is 2H as measured by the pencil hardness test, indicating successful modulation of optical properties without sacrificing substrate hardness.

  7. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision.

    PubMed

    Espandar, Ladan; Sikder, Shameema; Moshirfar, Majid

    2011-01-10

    Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD(™) lens is an aspheric, hydrophilic acrylic intraocular lens (IOL). The hydrophilic design of the lens is optimized to address dysphotopsia while maintaining biocompatibility, optical clarity, resistance to damage, and resistance to biocontamination. Aspheric lenses decrease postoperative spherical aberration. The addition of the Softec lens provides clinicians with another option for IOL placement; however, randomized comparative studies of this lens to others already on the market remain to be completed.

  8. Softec HD hydrophilic acrylic intraocular lens: biocompatibility and precision

    PubMed Central

    Espandar, Ladan; Sikder, Shameema; Moshirfar, Majid

    2011-01-01

    Intraocular lens development is driven by higher patient expectations for ideal visual outcomes. The recently US Food and Drug Administration-approved Softec HD™ lens is an aspheric, hydrophilic acrylic intraocular lens (IOL). The hydrophilic design of the lens is optimized to address dysphotopsia while maintaining biocompatibility, optical clarity, resistance to damage, and resistance to biocontamination. Aspheric lenses decrease postoperative spherical aberration. The addition of the Softec lens provides clinicians with another option for IOL placement; however, randomized comparative studies of this lens to others already on the market remain to be completed. PMID:21311658

  9. Induction Curing of Thiol-acrylate and Thiolene Composite Systems

    PubMed Central

    Ye, Sheng; Cramer, Neil B.; Stevens, Blake E.; Sani, Robert L.; Bowman, Christopher N.

    2011-01-01

    Induction curing is demonstrated as a novel type of in situ radiation curing that maintains most of the advantages of photocuring while eliminating the restriction of light accessibility. Induction curing is utilized to polymerize opaque composites comprised of thiol-acrylate and thiol-ene resins, nanoscale magnetic particles, and carbon nanotubes. Nanoscale magnetic particles are dispersed in the resin and upon exposure to the magnetic field, these particles lead to induction heating that rapidly initiates the polymerization. Heat transfer profiles and reaction kinetics of the samples are modeled during the reactions with varying induction heater power, species concentration, species type and sample thickness, and the model is compared with the experimental results. Thiol-ene polymerizations achieved full conversion between 1.5 minutes and 1 hour, depending on the field intensity and the composition, with the maximum reaction temperature decreasing from 146 – 87 °C when the induction heater power was decreased from 8 – 3 kW. The polymerization reactions of the thiol-acrylate system were demonstrated to achieve full conversion between 0.6 and 30 minutes with maximum temperatures from 139 to 86 °C. The experimental behavior was characterized and the temperature profile modeled for the thiol-acrylate composite comprised of sub100nm nickel particles and induction heater power in the range of 32 to 20 kW. A 9°C average deviation was observed between the modeling and experimental results for the maximum temperature rise. The model also was utilized to predict reaction temperatures and kinetics for systems with varying thermal initiator concentration, initiator half-life, monomer molecular weight and temperature gradients in samples with varying thickness, thereby demonstrating that induction curing represents a designable and tunable polymerization method. Finally, induction curing was utilized to cure thiol-acrylate systems containing carbon nanotubes where 1 wt

  10. Dimensional accuracy and stability of acrylic resin denture bases.

    PubMed

    Huggett, R; Zissis, A; Harrison, A; Dennis, A

    1992-10-01

    Proponents of injection molding systems have claimed a number of benefits over conventional press-pack dough molding systems. The aim of this study was to evaluate a recently developed injection (dry heat) procedure of processing compared with press-pack dough molding utilizing three curing cycles. The dimensional accuracy and stability of acrylic resin bases produced by the two molding procedures were compared. Dimensional changes were assessed over a period of 4 months using an optical comparator. The results demonstrate that baseplates produced by the injection molding procedure exhibit less shrinkage than those produced by the conventional press-pack procedures.

  11. Removable plate treatment of anterior forced crossbite: Effectiveness, efficiency, and potential outcome predictors.

    PubMed

    Bock, Niko C; Klewitz, Heidi; Hudel, Helge; Ruf, Sabine

    2015-07-01

    In addition to studying the effectiveness and efficiency of removable acrylic plates in correcting anterior forced crossbite, the influence of outcome predictors were evaluated. In all, 65 patients met the inclusion criteria of anterior forced crossbite, mixed dentition, removable plate treatment, and complete case documentation. Effectiveness was assessed based on pre- and posttreatment study casts (which were analyzed for successful treatment outcomes defined as ≥ 1 mm of overjet and overbite) and efficiency was assessed based on treatment duration and number of appointments. Potential outcome predictors were also evaluated, including age, gender, dental maturity, Angle Class, number of teeth in crossbite, severity of crossbite, overbite, ANB angle, Wits appraisal, mandibular plane angle, and patient compliance. Successful crossbite correction was achieved in 48 of the 65 patients (74%) within a median of 2.8 months and 2.0 appointments. Plate treatment was discontinued following another median of 11.6 months and 6.5 appointments. Promising outcome predictors are the number of teeth in crossbite (1-2 versus 3-4 teeth = success in 81 versus 42% of cases), dental maturity (early versus late mixed dentition = success in 84 versus 52% of cases), and Angle Class (I versus III = success in 83 versus 61% of cases). Removable acrylic plates were found to be moderately effective and efficient in correcting anterior forced crossbite. Children presenting with Angle Class I and crossbites involving not more than two teeth when treatment is started during the period of early mixed dentition had the best prognosis for treatment success.

  12. The Edge of Jupiter

    NASA Image and Video Library

    2017-04-19

    This enhanced color Jupiter image, taken by the JunoCam imager on NASA's Juno spacecraft, showcases several interesting features on the apparent edge (limb) of the planet. Prior to Juno's fifth flyby over Jupiter's mysterious cloud tops, members of the public voted on which targets JunoCam should image. This picture captures not only a fascinating variety of textures in Jupiter's atmosphere, it also features three specific points of interest: "String of Pearls," "Between the Pearls," and "An Interesting Band Point." Also visible is what's known as the STB Spectre, a feature in Jupiter's South Temperate Belt where multiple atmospheric conditions appear to collide. JunoCam images of Jupiter sometimes appear to have an odd shape. This is because the Juno spacecraft is so close to Jupiter that it cannot capture the entire illuminated area in one image -- the sides get cut off. Juno acquired this image on March 27, 2017, at 2:12 a.m. PDT (5:12 a.m. EDT), as the spacecraft performed a close flyby of Jupiter. When the image was taken, the spacecraft was about 12,400 miles (20,000 kilometers) from the planet. This enhanced color image was created by citizen scientist Bjorn Jonsson. https://photojournal.jpl.nasa.gov/catalog/PIA21389

  13. Widely tunable edge emitters

    NASA Astrophysics Data System (ADS)

    Sarlet, Gert; Wesstrom, Jan-Olof; Rigole, Pierre-Jean; Broberg, Bjoern

    2001-11-01

    We will present the current state-of-the-art in widely tunable edge emitting lasers for WDM applications. Typical applications for a tunable laser will be discussed, and the different types of tunable lasers available today will be compared with respect to the requirements posed by these applications. We will focus on the DBR-type tunable lasers - DBR, SG-DBR and GCSR - which at present seem to be the only tunable lasers mature enough for real-life applications. Their main advantages are that they are all monolithic, with no moving parts, and can be switched from one frequency to the other very rapidly since the tuning is based on carrier injection and not on thermal or mechanical changes. We will briefly discuss the working principle of each of these devices, and present typical performance characteristics. From a manufacturing point of view, rapid characterization of the lasers is crucial; therefore an overview will be given of different characterization schemes that have recently been proposed. For the end user, reliability is the prime issue. We will show results of degradation studies on these lasers and outline how the control electronics that drive the laser can compensate for any frequency drift. Finally, we will also discuss the impact of the requirement for rapid frequency switching on the design of the control electronics.

  14. Wing Leading Edge Debris Analysis

    NASA Technical Reports Server (NTRS)

    Shah, Sandeep; Jerman, Gregory

    2004-01-01

    This is a slide presentation showing the Left Wing Leading Edge (WLE) heat damage observations: Heavy "slag" deposits on select RCC panels. Eroded and knife-edged RCC rib sections. Excessive overheating and slumping of carrier panel tiles. Missing or molten attachment bolts but intact bushing. Deposit mainly on "inside" RCC panel. Deposit on some fractured RCC surface

  15. Rock Segmentation through Edge Regrouping

    NASA Technical Reports Server (NTRS)

    Burl, Michael

    2008-01-01

    Rockster is an algorithm that automatically identifies the locations and boundaries of rocks imaged by the rover hazard cameras (hazcams), navigation cameras (navcams), or panoramic cameras (pancams). The software uses edge detection and edge regrouping to identify closed contours that separate the rocks from the background.

  16. Improved Edge Performance in MRF

    NASA Technical Reports Server (NTRS)

    Shorey, Aric; Jones, Andrew; Durnas, Paul; Tricard, Marc

    2004-01-01

    The fabrication of large segmented optics requires a polishing process that can correct the figure of a surface to within a short distance from its edges-typically, a few millimeters. The work here is to develop QED's Magnetorheological Finishing (MRF) precision polishing process to minimize residual edge effects.

  17. Dense opacification of the optical component of a hydrophilic acrylic intraocular lens: a clinicopathological analysis of 9 explanted lenses.

    PubMed

    Werner, L; Apple, D J; Kaskaloglu, M; Pandey, S K

    2001-09-01

    To report clinical, pathological, histochemical, ultrastructural, and spectrographic analyses of explanted hydrophilic acrylic intraocular lenses (IOLs) obtained from patients who had visual disturbances caused by postoperative opacification of the lens optic. Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA, and Ege University, Alsancak Izmir, Turkey. Nine hydrophilic IOLs (SC60B-OUV, MDR Inc.) were explanted from 9 patients with decreased visual acuity. Most patients became symptomatic approximately 24 months after uneventful phacoemulsification and IOL implantation. Opacification was noted and appeared clinically to be associated with a fine granularity within the substance of the IOL optic. The IOLs were forwarded to the center and examined by gross and light microscopy. Full-thickness cut sections of the optics were stained with 1% alizarin red and the von Kossa method (special stains for calcium). Some were submitted for scanning electron microscopy and energy dispersive x-ray spectroscopy. Microscopic analyses revealed multiple fine, granular deposits of variable sizes within the lens optics, usually distributed in a line parallel to the anterior and posterior curvatures of the optic, with a clear zone just beneath the optic surface. The deposits stained positive with alizarin red and the von Kossa method. Energy dispersive x-ray spectroscopy of the internal substance of sectioned IOLs demonstrated the presence of calcium within the deposits. This is the first clinicopathological report of optic opacification occurring with this hydrophilic acrylic IOL model. Studies of similar cases with this lens should be done to determine the incidence and possible mechanisms of the phenomenon.

  18. Light transmittance of 1-piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes.

    PubMed

    Werner, Liliana; Morris, Caleb; Liu, Erica; Stallings, Shannon; Floyd, Anne; Ollerton, Andrew; Leishman, Lisa; Bodnar, Zachary

    2014-01-01

    To assess the potential effect of surface light scattering on light transmittance of 1-piece hydrophobic acrylic intraocular lenses (IOLs) with or without a blue-light filter. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Intraocular lenses were obtained from human cadavers (49 IOLs total; 36 with blue-light filter) and from finished-goods inventory (controls). The IOLs were removed from cadaver eyes and the power and model matched to unused controls. After surface proteins were removed, the IOLs were hydrated for 24 hours at room temperature. Surface light scattering was measured with a Scheimpflug camera (EAS-1000 Anterior Segment Analysis System). Light transmittance was measured with a Lambda 35 UV/Vis spectrophotometer (single-beam configuration; RSA-PE-20 integrating sphere). Hydrated scatter values ranged from 4.8 to 202.5 computer-compatible tape (CCT) units for explanted IOLs with blue-light filter and 1.5 to 11.8 CCT units for controls; values ranged from 6.0 to 137.5 CCT units for explanted IOLs without a blue-light filter and 3.5 to 9.6 CCT units for controls. In both groups, there was a tendency toward increasing scatter values with increasing postoperative time. No differences in light transmittance were observed between explanted IOLs and controls in both groups (IOLs with blue-light filter: P=.407; IOL with no blue-light filter: P=.487; both paired t test). Although surface light scattering of explanted IOLs was significantly higher than that of controls and appeared to increase with time, no effect was observed on light transmittance of 1-piece hydrophobic acrylic IOLs with or without a blue-light filter. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of a new single-piece 4% water content hydrophobic acrylic intraocular lens in the rabbit model.

    PubMed

    Ollerton, Andrew; Werner, Liliana; Fuller, Stanley R; Kavoussi, Shaheen C; McIntyre, J Steele; Mamalis, Nick

    2012-10-01

    To evaluate uveal and capsular biocompatibility of a 1-piece intraocular lens (IOL) manufactured from a new hydrophobic acrylic material that incorporates a barrier step at the optic-haptic junctions. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. The study IOL (Eternity-Uni W-60) was implanted in the right eyes of 5 New Zealand rabbits and the control IOL (Acrysof SN60WF) in the left eyes. Slitlamp examination was performed 1 through 4 weeks postoperatively. After death, the globes were enucleated and fixed in formalin. Capsular bag opacification scoring (Miyake-Apple view) was then performed followed by complete histopathology. At the 4-week examination, the mean posterior capsule opacification (PCO) score was 1.5 ± 1.0 (SD) in the study group and 2.2 ± 1.09 in the control group (P=.02). Anterior capsule opacification (ACO) was not present in the study eyes and was mild in the control eyes. On gross examination, the mean central PCO score was 0.9 ± 0.65 in the study group and 1.7 ± 1.20 in the control group (P=.07); the mean peripheral PCO score was 1.3 ± 0.67 and 2.4 ± 1.14 (P=.01) and the mean Soemmerring ring score was 3.8 ± 0.44 and 4.2 ± 1.09, respectively (P=.47). Histopathology confirmed that both IOLs were equally tolerated by the rabbit eyes. In this rabbit study, the new hydrophobic acrylic material was biocompatible. The barrier step incorporated to the optic-haptic junctions has the potential to enhance PCO prevention. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Anterior cruciate ligament - updating article.

    PubMed

    Luzo, Marcus Vinicius Malheiros; Franciozi, Carlos Eduardo da Silveira; Rezende, Fernando Cury; Gracitelli, Guilherme Conforto; Debieux, Pedro; Cohen, Moisés

    2016-01-01

    This updating article on the anterior cruciate ligament (ACL) has the aim of addressing some of the most interesting current topics in this field. Within this stratified approach, it contains the following sections: ACL remnant; anterolateral ligament and combined intra and extra-articular reconstruction; fixation devices; and ACL femoral tunnel creation techniques.

  1. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture.

    PubMed

    Jang, Dae-Eun; Lee, Ji-Young; Jang, Hyun-Seon; Lee, Jang-Jae; Son, Mee-Kyoung

    2015-08-01

    The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

  2. Preparation and properties of acrylic resin coating modified by functional graphene oxide

    NASA Astrophysics Data System (ADS)

    Dong, Rui; Liu, Lili

    2016-04-01

    To improve the dispersion and the strength of filler-matrix interface in acrylic resin, the functional graphene oxide (FGO) was obtained by surface modification of graphene oxide (GO) by γ-methacryloxypropyl trimethoxysilane (KH-570) and then the acrylic nanocomposites containing different loadings of GO and FGO were prepared. The structure, morphology and dispersion/exfoliation of the FGO were characterized by XRD, FT-IR, Raman, XPS, SEM and TEM. The results demonstrated that the KH-570 was successfully grafted onto the surface of GO sheets. Furthermore, the corresponding thermal, mechanical and chemical resistance properties of the acrylic nanocomposites filled with the FGO were studied and compared with those of neat acrylic and GO/acrylic nanocomposites. The results revealed that the loading of FGO effectively enhanced various properties of acrylic resin. These findings confirmed that the dispersion and interfacial interaction were greatly improved by incorporation of FGO, which might be the result of covalent bonds between the FGO and the acrylic matrix. This work demonstrates an in situ polymerization method to construct a flexible interphase structure, strong interfacial interaction and good dispersion of FGO in acrylic nanocomposites, which can reinforce the polymer properties and be applied in research and industrial areas.

  3. Control of contamination of radon-daughters in the DEAP-3600 acrylic vessel

    SciTech Connect

    Jillings, Chris; Collaboration: DEAP Collaboration; and others

    2013-08-08

    DEAP-3600 is a 3600kg single-phase liquid-argon dark matter detector under construction at SNOLAB with a sensitivity of 10{sup −46}cm{sup 2} for a 100 GeV WIMP. The argon is held an an acrylic vessel coated with wavelength-shifting 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). Acrylic was chosen because it is optically transparent at the shifted wavelength of 420 nm; an effective neutron shield; and physically strong. With perfect cleaning of the acrylic surface before data taking the irreducible background is that from bulk {sup 210}Pb activity that is near the surface. To achieve a background rate of 0.01 events in the 1000-kg fiducial volume per year of exposure, the allowed limit of Pb-210 in the bulk acrylic is 31 mBq/tonne (= 1.2 × 10{sup −20}g/g). We discuss how pure acrylic was procured and manufactured into a complete vessel paying particular attention to exposure to radon during all processes. In particular field work at the acrylic panel manufacturer, RPT Asia, and acrylic monomer supplier, Thai MMA Co. Ltd, in Thailand is described. The increased diffusion of radon during annealing the acrylic at 90C as well as techniques to mitigate against this are described.

  4. 40 CFR 721.10530 - Acrylate manufacture byproduct distillation residue (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... distillation residue (generic). 721.10530 Section 721.10530 Protection of Environment ENVIRONMENTAL PROTECTION... New Uses for Specific Chemical Substances § 721.10530 Acrylate manufacture byproduct distillation... substance is identified generically as acrylate manufacture byproduct distillation residue (PMN P-12-87)...

  5. 40 CFR 721.10530 - Acrylate manufacture byproduct distillation residue (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... distillation residue (generic). 721.10530 Section 721.10530 Protection of Environment ENVIRONMENTAL PROTECTION... New Uses for Specific Chemical Substances § 721.10530 Acrylate manufacture byproduct distillation... substance is identified generically as acrylate manufacture byproduct distillation residue (PMN P-12-87)...

  6. Synthesis of Radiation Curable Palm Oil-Based Epoxy Acrylate: NMR and FTIR Spectroscopic Investigations.

    PubMed

    Salih, Ashraf M; Ahmad, Mansor Bin; Ibrahim, Nor Azowa; Dahlan, Khairul Zaman Hj Mohd; Tajau, Rida; Mahmood, Mohd Hilmi; Yunus, Wan Md Zin Wan

    2015-08-04

    Over the past few decades, there has been an increasing demand for bio-based polymers and resins in industrial applications, due to their potential lower cost and environmental impact compared with petroleum-based counterparts. The present research concerns the synthesis of epoxidized palm oil acrylate (EPOLA) from an epoxidized palm oil product (EPOP) as environmentally friendly material. EPOP was acrylated by acrylic acid via a ring opening reaction. The kinetics of the acrylation reaction were monitored throughout the reaction course and the acid value of the reaction mixture reached 10 mg KOH/g after 16 h, indicating the consumption of the acrylic acid. The obtained epoxy acrylate was investigated intensively by means of FTIR and NMR spectroscopy, and the results revealed that the ring opening reaction was completed successfully with an acrylation yield about 82%. The UV free radical polymerization of EPOLA was carried out using two types of photoinitiators. The radiation curing behavior was determined by following the conversion of the acrylate groups. The cross-linking density and the hardness of the cured EPOLA films were measured to evaluate the effect of the photoinitiator on the solid film characteristics, besides, the thermal and mechanical properties were also evaluated.

  7. Lactate and acrylate metabolism by Megasphaera elsdenii under batch and steady-state conditions.

    PubMed

    Prabhu, Rupal; Altman, Elliot; Eiteman, Mark A

    2012-12-01

    The growth of Megasphaera elsdenii on lactate with acrylate and acrylate analogues was studied under batch and steady-state conditions. Under batch conditions, lactate was converted to acetate and propionate, and acrylate was converted into propionate. Acrylate analogues 2-methyl propenoate and 3-butenoate containing a terminal double bond were similarly converted into their respective saturated acids (isobutyrate and butyrate), while crotonate and lactate analogues 3-hydroxybutyrate and (R)-2-hydroxybutyrate were not metabolized. Under carbon-limited steady-state conditions, lactate was converted to acetate and butyrate with no propionate formed. As the acrylate concentration in the feed was increased, butyrate and hydrogen formation decreased and propionate was increasingly generated, while the calculated ATP yield was unchanged. M. elsdenii metabolism differs substantially under batch and steady-state conditions. The results support the conclusion that propionate is not formed during lactate-limited steady-state growth because of the absence of this substrate to drive the formation of lactyl coenzyme A (CoA) via propionyl-CoA transferase. Acrylate and acrylate analogues are reduced under both batch and steady-state growth conditions after first being converted to thioesters via propionyl-CoA transferase. Our findings demonstrate the central role that CoA transferase activity plays in the utilization of acids by M. elsdenii and allows us to propose a modified acrylate pathway for M. elsdenii.

  8. Lactate and Acrylate Metabolism by Megasphaera elsdenii under Batch and Steady-State Conditions

    PubMed Central

    Prabhu, Rupal; Altman, Elliot

    2012-01-01

    The growth of Megasphaera elsdenii on lactate with acrylate and acrylate analogues was studied under batch and steady-state conditions. Under batch conditions, lactate was converted to acetate and propionate, and acrylate was converted into propionate. Acrylate analogues 2-methyl propenoate and 3-butenoate containing a terminal double bond were similarly converted into their respective saturated acids (isobutyrate and butyrate), while crotonate and lactate analogues 3-hydroxybutyrate and (R)-2-hydroxybutyrate were not metabolized. Under carbon-limited steady-state conditions, lactate was converted to acetate and butyrate with no propionate formed. As the acrylate concentration in the feed was increased, butyrate and hydrogen formation decreased and propionate was increasingly generated, while the calculated ATP yield was unchanged. M. elsdenii metabolism differs substantially under batch and steady-state conditions. The results support the conclusion that propionate is not formed during lactate-limited steady-state growth because of the absence of this substrate to drive the formation of lactyl coenzyme A (CoA) via propionyl-CoA transferase. Acrylate and acrylate analogues are reduced under both batch and steady-state growth conditions after first being converted to thioesters via propionyl-CoA transferase. Our findings demonstrate the central role that CoA transferase activity plays in the utilization of acids by M. elsdenii and allows us to propose a modified acrylate pathway for M. elsdenii. PMID:23023753

  9. The Robotic Edge Finishing Laboratory

    SciTech Connect

    Loucks, C.S.; Selleck, C.B.

    1990-08-01

    The Robotic Edge Finishing Laboratory at Sandia National Laboratories is developing four areas of technology required for automated deburring, chamfering, and blending of machined edges: (1) the automatic programming of robot trajectories and deburring processes using information derived from a CAD database, (2) the use of machine vision for locating the workpiece coupled with force control to ensure proper tool contact, (3) robotic deburring, blending, and machining of precision chamfered edges, and (4) in-process automated inspection of the formed edge. The Laboratory, its components, integration, and results from edge finishing experiments to date are described here. Also included is a discussion of the issues regarding implementation of the technology in a production environment. 24 refs., 17 figs.

  10. Yet another method for marking incisal edges of teeth for bitemark analysis.

    PubMed

    Metcalf, Roger D

    2008-03-01

    Over the years many methods have been proposed and presented for marking or "highlighting" the incisal edges of anterior teeth on a dental stone model -- one of the critical steps in production of transparent overlays for bitemark analysis. A method is presented here that is an extension and refinement of the "paint the edges" method shown at least as early as 1966 by Gustafson. This method uses "invisible ink" and ultraviolet illumination to produce a very high contrast image of the incisal edges of the teeth on the model. The advantages of this new method are that it is nondestructive, it does not leave visible marks on the models, operator subjectivity in selecting the portions of anterior teeth to be highlighted is reduced, and the author submits that this technique lends itself to easy construction of overlays using computer image-processing software such as Adobe Photoshop and ImageJ.

  11. The acute aquatic toxicity of a series of acrylate and methacrylate esters

    SciTech Connect

    Staples, C.A.; McLaughlin, J.E.; Hamilton, J.D.

    1994-12-31

    Acute aquatic toxicity data for several acrylate and methacrylate esters were reviewed. Acrylates included acrylic acid, ethyl-, and butyl-acrylate. Methacrylates included methacrylic acid, methyl-, and butyl-methacrylate. Tests were 48 hr or 96 hr standard flow through (invertebrates and fish) assays (measured exposure concentrations). These data are currently used in a risk assessment of acrylate/methacrylate environmental safety. Algal growth (Selanastrum capricomutum) 96 hr EC{sub 50}s were 0.17 mg/L (NOEC < 0.13 mg/L) for acrylic acid, 11.0 mg/L (NOEC < 6.5 mg/L) for ethyl acrylate, and 5.2 mg/L (NOEC < 3.8 mg/L) for butyl acrylate. Invertebrate (Daphnia magna) 48 hr LC{sub 50}s were 95.0 mg/L (NOEC 23.0 mg/L) for acrylic acid, 7.9 mg/L (NOEC 3.4 mg/L) for ethyl acrylate, and 8.2 mg/L (NOEC 2.4 mg/L) for butyl acrylate. Rainbow trout (Oncorhynchus mykiss) 96 hr LC{sub 50}s were 27.0 mg/L (NOEC 6.3 mg/L) for acrylic acid, 4.6 mg/L (NOEC 0.78 mg/L) for ethyl acrylate, and 5.2 mg/L (NOEC 3.8 mg/L) for butyl acrylate. Algae 96 hr EC{sub 50}s were 0.59 mg/L (NOEC 0.38 mg/L) for methacrylic acid, 170.0 mg/L (NOEC 100.0 mg/L) for methyl methacrylate, and 130.0 mg/L for butyl methacrylate. Daphnia magna 48 hr LC{sub 50}s were > 130.0 mg/L (NOEC 130.0 mg/L) for methacrylic acid, 69.0 mg/L (NOEC 48.0 mg/L) for methyl methacrylate, and 32.0 mg/L (NOEC 23.0 mg/L) for butyl methacrylate. Trout 96 hr LC{sub 50}s were 85.0 mg/L (NOEC 12.0 mg/L) for methacrylic acid and > 79.0 mg/L (NOEC 40.0 mg/L) for methyl methacrylate. The fathead minnow (Pimephales promelas) 96 hr LC{sub 50} was 11.0 mg/L for butyl methacrylate.

  12. Effect of Beverages on the Hardness and Tensile Bond Strength of Temporary Acrylic Soft Liners to Acrylic Resin Denture Base

    PubMed Central

    Safari, A; Vojdani, M; Mogharrabi, S; Iraji Nasrabadi, N; Derafshi, R

    2013-01-01

    Statement of Problem: Two potential problems commonly identified with a denture base incorporating a resilient liner are failure of the bond between acrylic resin and soft liner material, and loss of resiliency of the soft liner over time. Since patients may drink different beverages, it is important to evaluate their effects on physical properties of soft lining materials. Purpose: The objective of this in vitro study was to evaluate the effect of different beverages on the hardness of two temporary acrylic-based soft lining materials and their bond strength to the denture base resin. Materials and Method: For the hardness test; a total of 80 rectangular specimens (40mm×10mm×3mm) were fabricated from a heat-polymerized polymethylmethacrylate. Two commercially auto-polymerized acrylic resin-based resilient liners; Coe-Soft and Visco-gel were prepared according to the manufacturers’ instructions and applied on the specimens. For the tensile test, 160 cylindrical specimens (30mm×10mm) were prepared. The liners were added between specimens with a thickness of 3 mm. The specimens of both soft liners were divided into 4 groups (n=10) and immersed in distilled water as the control group, Coca-Cola, 8% and 50% ethanol. All groups were stored in separate containers at 37oC for 12 days. All beverages were changed daily. The hardness was determined using a Shore A durometer and tensile bond strength was determined in a ZwickRoell testing machine at a cross-head speed of 5mm/min. The results were analyzed using two-way ANOVA. Results: There was no significant interaction between the soft liners and the drinks for both hardness (p= 0.748) and bond strength (p= 0.902). There were statistically significant differences between all drinks for both hardness (p< 0.001) and bond strength (p< 0.05). Conclusion: Within the limitations of this study, it seems that drinking Coca-Cola and alcoholic beverages would not be potentially causing any problems for the temporary

  13. Effect of beverages on the hardness and tensile bond strength of temporary acrylic soft liners to acrylic resin denture base.

    PubMed

    Safari, A; Vojdani, M; Mogharrabi, S; Iraji Nasrabadi, N; Derafshi, R

    2013-12-01

    Two potential problems commonly identified with a denture base incorporating a resilient liner are failure of the bond between acrylic resin and soft liner material, and loss of resiliency of the soft liner over time. Since patients may drink different beverages, it is important to evaluate their effects on physical properties of soft lining materials. The objective of this in vitro study was to evaluate the effect of different beverages on the hardness of two temporary acrylic-based soft lining materials and their bond strength to the denture base resin. For the hardness test; a total of 80 rectangular specimens (40mm×10mm×3mm) were fabricated from a heat-polymerized polymethylmethacrylate. Two commercially auto-polymerized acrylic resin-based resilient liners; Coe-Soft and Visco-gel were prepared according to the manufacturers' instructions and applied on the specimens. For the tensile test, 160 cylindrical specimens (30mm×10mm) were prepared. The liners were added between specimens with a thickness of 3 mm. The specimens of both soft liners were divided into 4 groups (n=10) and immersed in distilled water as the control group, Coca-Cola, 8% and 50% ethanol. All groups were stored in separate containers at 37(o)C for 12 days. All beverages were changed daily. The hardness was determined using a Shore A durometer and tensile bond strength was determined in a ZwickRoell testing machine at a cross-head speed of 5mm/min. The results were analyzed using two-way ANOVA. There was no significant interaction between the soft liners and the drinks for both hardness (p= 0.748) and bond strength (p= 0.902). There were statistically significant differences between all drinks for both hardness (p< 0.001) and bond strength (p< 0.05). Within the limitations of this study, it seems that drinking Coca-Cola and alcoholic beverages would not be potentially causing any problems for the temporary acrylic soft liners.

  14. Effect of the Mitral Valve's Anterior Leaflet on Axisymmetry of Transmitral Vortex Ring.

    PubMed

    Falahatpisheh, Ahmad; Pahlevan, Niema M; Kheradvar, Arash

    2015-10-01

    The shape and formation of transmitral vortex ring are shown to be associated with diastolic function of the left ventricle (LV). Transmitral vortex ring is a flow feature that is observed to be non-axisymmetric in a healthy heart and its inherent asymmetry in the LV assists in efficient ejection of the blood during systole. This study is a first step towards understanding the effects of the mitral valve's anterior leaflet on transmitral flow. We experimentally study a single-leaflet model of the mitral valve to investigate the effect of the anterior leaflet on the axisymmetry of the generated vortex ring based on the three-dimensional data acquired using defocusing digital particle image velocimetry. Vortex rings form downstream of a D-shaped orifice in presence or absence of the anterior leaflet in various physiological stroke ratios. The results of the statistical analysis indicate that the formed vortex ring downstream of a D-shaped orifice is markedly non-axisymmetric, and presence of the anterior leaflet improves the ring's axisymmetry. This study suggests that the improvement of axisymmetry in presence of the anterior leaflet might be due to coupled dynamic interaction between rolling-up of the shear layer at the edges of the D-shaped orifice and the borders of the anterior leaflet. This interaction can reduce the non-uniformity in vorticity generation, which results in more axisymmetric behavior compared to the D-shaped orifice without the anterior leaflet.

  15. Tbx2 regulates anterior neural specification by repressing FGF signaling pathway.

    PubMed

    Cho, Gun-Sik; Park, Dong-Seok; Choi, Sun-Cheol; Han, Jin-Kwan

    2017-01-15

    During early embryogenesis, FGF signals regulate the antero-posterior (AP) patterning of the neural plate by promoting posterior cell fates. In particular, BMP signal-mediated attenuation of FGF pathway plays a critical role in the determination of the anterior neural region. Here we show that Tbx2, a T-box transcriptional repressor regulates anterior neural specification by suppressing FGF8 signaling pathway in Xenopus embryo. Tbx2 is expressed in the anterior edge of the neural plate in early neurulae. Overexpression and knockdown of Tbx2 induce expansion and reduction in the expression of anterior neural markers, respectively. It also suppresses FGF8-induced ERK phosphorylation and neural caudalization. Tbx2, which is a target gene of BMP signal, down-regulates FGF8 signaling by inhibiting the expression of Flrt3, a positive regulator of this pathway. We found that Tbx2 binds directly to the T-box element located in the promoter region of Flrt3 gene, thereby interfering with the activity of the promoter. Consistently, Tbx2 augmentation of anterior neural formation is inhibited by co-expression of Flrt3. Furthermore, disruption of the anterior-most structures such as eyes in Tbx2-depleted embryos can be rescued by inhibition of Flrt3 function or FGF signaling. Taken together, our results suggest that Tbx2 mediates BMP signal to down-regulate FGF signaling pathway by repressing Flrt3 expression for anterior tissue formation.

  16. Edge-on Galaxy

    NASA Technical Reports Server (NTRS)

    1999-01-01

    NASA's Hubble Space Telescope has imaged an unusual edge-on galaxy, revealing remarkable details of its warped dusty disc and showing how colliding galaxies trigger the birth of new stars.

    The image, taken by Hubble's Wide Field and Planetary Camera 2 (WFPC2), is online at http://heritage.stsci.edu and http://www.jpl.nasa.gov/images/wfpc. The camera was designed and built by NASA's Jet Propulsion Laboratory, Pasadena, Calif. During observations of the galaxy, the camera passed a milestone, taking its 100,000th image since shuttle astronauts installed it in Hubble in 1993.

    The dust and spiral arms of normal spiral galaxies, like our Milky Way, look flat when seen edge- on. The new image of the galaxy ESO 510-G13 shows an unusual twisted disc structure, first seen in ground-based photographs taken at the European Southern Observatory in Chile. ESO 510-G13 lies in the southern constellation Hydra, some 150 million light-years from Earth. Details of the galaxy's structure are visible because interstellar dust clouds that trace its disc are silhouetted from behind by light from the galaxy's bright, smooth central bulge.

    The strong warping of the disc indicates that ESO 510-G13 has recently collided with a nearby galaxy and is in the process of swallowing it. Gravitational forces distort galaxies as their stars, gas, and dust merge over millions of years. When the disturbances die out, ESO 510-G13 will be a single galaxy.

    The galaxy's outer regions, especially on the right side of the image, show dark dust and bright clouds of blue stars. This indicates that hot, young stars are forming in the twisted disc. Astronomers believe star formation may be triggered when galaxies collide and their interstellar clouds are compressed.

    The Hubble Heritage Team used WFPC2 to observe ESO 510-G13 in April 2001. Pictures obtained through blue, green, and red filters were combined to make this color-composite image, which emphasizes the contrast between the dusty

  17. Edge-on Galaxy

    NASA Technical Reports Server (NTRS)

    1999-01-01

    NASA's Hubble Space Telescope has imaged an unusual edge-on galaxy, revealing remarkable details of its warped dusty disc and showing how colliding galaxies trigger the birth of new stars.

    The image, taken by Hubble's Wide Field and Planetary Camera 2 (WFPC2), is online at http://heritage.stsci.edu and http://www.jpl.nasa.gov/images/wfpc. The camera was designed and built by NASA's Jet Propulsion Laboratory, Pasadena, Calif. During observations of the galaxy, the camera passed a milestone, taking its 100,000th image since shuttle astronauts installed it in Hubble in 1993.

    The dust and spiral arms of normal spiral galaxies, like our Milky Way, look flat when seen edge- on. The new image of the galaxy ESO 510-G13 shows an unusual twisted disc structure, first seen in ground-based photographs taken at the European Southern Observatory in Chile. ESO 510-G13 lies in the southern constellation Hydra, some 150 million light-years from Earth. Details of the galaxy's structure are visible because interstellar dust clouds that trace its disc are silhouetted from behind by light from the galaxy's bright, smooth central bulge.

    The strong warping of the disc indicates that ESO 510-G13 has recently collided with a nearby galaxy and is in the process of swallowing it. Gravitational forces distort galaxies as their stars, gas, and dust merge over millions of years. When the disturbances die out, ESO 510-G13 will be a single galaxy.

    The galaxy's outer regions, especially on the right side of the image, show dark dust and bright clouds of blue stars. This indicates that hot, young stars are forming in the twisted disc. Astronomers believe star formation may be triggered when galaxies collide and their interstellar clouds are compressed.

    The Hubble Heritage Team used WFPC2 to observe ESO 510-G13 in April 2001. Pictures obtained through blue, green, and red filters were combined to make this color-composite image, which emphasizes the contrast between the dusty

  18. Influence of Sea Water Aging on the Mechanical Behaviour of Acrylic Matrix Composites

    NASA Astrophysics Data System (ADS)

    Davies, P.; Le Gac, P.-Y.; Le Gall, M.

    2017-02-01

    A new matrix resin was recently introduced for composite materials, based on acrylic resin chemistry allowing standard room temperature infusion techniques to be used to produce recyclable thermoplastic composites. This is a significant advance, particularly for more environmentally-friendly production of large marine structures such as boats. However, for such applications it is essential to demonstrate that composites produced with these resins resist sea water exposure in service. This paper presents results from a wet aging study of unreinforced acrylic and glass and carbon fibre reinforced acrylic composites. It is shown that the acrylic matrix resin is very stable in seawater, showing lower property losses after seawater aging than those of a commonly-used epoxy matrix resin. Carbon fibre reinforced acrylic also shows good property retention after aging, while reductions in glass fibre reinforced composite strengths suggest that specific glass fibre sizing may be required for optimum durability.

  19. Biocatalytic synthesis of maltodextrin-based acrylates from starch and α-cyclodextrin.

    PubMed

    Kloosterman, Wouter M J; Spoelstra-van Dijk, Gerda; Loos, Katja

    2014-09-01

    Novel 2-(β-maltooligooxy)-ethyl (meth)acrylate monomers are successfully synthesized by CGTase from Bacillus macerans catalyzed coupling of 2-(β-glucosyloxy)-ethyl acrylate and methacrylate with α-cyclodextrin or starch. HPLC-UV analysis shows that the CGTase catalyzed reaction yields 2-(β-maltooligooxy)-ethyl acrylates with 1 to 15 glucopyranosyl units. (1) H NMR spectroscopy reveals that the β-linkage in the acceptor molecule is preserved during the CGTase catalyzed coupling reaction, whereas the newly introduced glucose units are attached by α-(1,4)-glycosidic linkages. The synthesized 2-(β-maltooligooxy)-ethyl acrylate monomers are successfully polymerized by aqueous free radical polymerization to yield the comb-shaped glycopolymer poly(2-(β-maltooligooxy)-ethyl acrylate).

  20. Influence of Sea Water Aging on the Mechanical Behaviour of Acrylic Matrix Composites

    NASA Astrophysics Data System (ADS)

    Davies, P.; Le Gac, P.-Y.; Le Gall, M.

    2016-07-01

    A new matrix resin was recently introduced for composite materials, based on acrylic resin chemistry allowing standard room temperature infusion techniques to be used to produce recyclable thermoplastic composites. This is a significant advance, particularly for more environmentally-friendly production of large marine structures such as boats. However, for such applications it is essential to demonstrate that composites produced with these resins resist sea water exposure in service. This paper presents results from a wet aging study of unreinforced acrylic and glass and carbon fibre reinforced acrylic composites. It is shown that the acrylic matrix resin is very stable in seawater, showing lower property losses after seawater aging than those of a commonly-used epoxy matrix resin. Carbon fibre reinforced acrylic also shows good property retention after aging, while reductions in glass fibre reinforced composite strengths suggest that specific glass fibre sizing may be required for optimum durability.

  1. The study of synthesis and photocuring behaviors of organic silicon modified methylacrylate and acrylate

    NASA Astrophysics Data System (ADS)

    Wang, Si-yuan; Zou, Ying-quan

    2012-03-01

    Ten different silicon-containing methyl acrylate and acrylate monomers were synthesized by the substitution reaction of chlorosilanes or chlorosiloxanes with 2-Hydroxyethyl methacrylate or 2-Hydroxyethyl acrylate. Using triethylamine as the catalytic agent, tetrahydrofuran as the solvent, pure products can be obtained with one-step reaction after reduced pressure distillation or column chromatography via controlling raw ratio and reaction time. In this study, one to four silicon contained methyl acrylate and acrylate monomers were synthesized with simple methd and high yield. Monomers' properties were characterized through IR, 1H-NMR, 13C-NMR and their viscosity and thermostability were also characterized. The polymers' have good performance on UV-curing and low surface energy.

  2. Characteristics and mechanisms of acrylate polymer damage to maize seedlings.

    PubMed

    Chen, Xian; Mao, Xiaoyun; Lu, Qin; Liao, Zongwen; He, Zhenli

    2016-07-01

    Superabsorbent acrylate polymers (SAPs) have been widely used to maintain soil moisture in agricultural management, but they may cause damage to plants, and the mechanisms are not well understood. In this study, seed germination, soil pot culture, hydroponic experiments, and SAPs degradation were conducted to investigate damage characteristics and mechanisms associated with SAPs application. The Results showed that SAPs inhibited maize growth and altered root morphology (irregular and loose arrangement of cells and breakage of cortex parenchyma), and the inhibitory effects were enhanced at higher SAPs rates. After 1h SAP hydrogels treatment, root malondialdehyde (MDA) content was significantly increased, while superoxide dismutase (SOD) and catalase (CAT) content were significantly decreased. Hydroponics experiment indicated that root and shoot growth was inhibited at 2.5mgL(-1) acrylic acid (AA), and the inhibition was enhanced with increasing AA rates. This effect was exacerbated by the presence of Na(+) at a high concentration in the hydrogels. Release and degradation of AA were enhanced at higher soil moisture levels. A complete degradation of AA occurred between 15 and 20 days after incubation (DAI), but it took longer for Na(+) concentration to decrease to a safe level. These results indicate that high concentration of both AA and Na(+) present in the SAPs inhibits plant growth. The finding of this study may provide a guideline for appropriate application of SAPs in agriculture.

  3. The adhesion of modern soft relining materials to acrylic dentures.

    PubMed

    Więckiewicz, Włodzimierz; Kasperski, Jacek; Więckiewicz, Mieszko; Miernik, Marta; Król, Wojciech

    2014-01-01

    Silicone-based liners are widespread materials in prosthetic dentistry. Their mechanical properties have to meet several key requirements such as adequate adhesion to denture base polymers in order to provide right function of masticatory system and oral hygiene. The aim of this paper was to evaluate and compare tensile and shear bond strengths values of three modern autopolimeryzed silicone relining materials bonded to acrylic plates. Three silicone-based soft relining materials were investigated in this study (A-Soft Line 30, Bosworth Dentusil and Elite Super Soft). A total of 78 specimens were prepared: 13 of each material (total: 39) for testing tensile bond strength and 13 of each material for testing shear bond strength (total: 39). The obtained data were analyzed statistically. The average tensile bond strength results were 0.86 MPa for Bosworth Dentusil, 1.00 MPa for Elite Super Soft and 1.25 MPa for A-Soft Line 30. The silicone-based relining materials had different average values of shear bond strength: 0.67 MPa Elite Super Soft; 1.32 MPa A-Soft Line 30 and 1.57 MPa Bosworth Dentusil. As the result of the study it can be concluded that all tested materials have acceptable adhesion values to acrylic resin. According to tensile and shear bond strengths tests the best adhesive properties has A-Soft Line 30.

  4. Acrylic Resin Molding Based Head Fixation Technique in Rodents.

    PubMed

    Roh, Mootaek; Lee, Kyungmin; Jang, Il-Sung; Suk, Kyoungho; Lee, Maan-Gee

    2016-01-12

    Head fixation is a technique of immobilizing animal's head by attaching a head-post on the skull for rigid clamping. Traditional head fixation requires surgical attachment of metallic frames on the skull. The attached frames are then clamped to a stationary platform resulting in immobilization of the head. However, metallic frames for head fixation have been technically difficult to design and implement in general laboratory environment. In this study, we provide a novel head fixation method. Using a custom-made head fixation bar, head mounter is constructed during implantation surgery. After the application of acrylic resin for affixing implants such as electrodes and cannula on the skull, additional resins applied on top of that to build a mold matching to the port of the fixation bar. The molded head mounter serves as a guide rails, investigators conveniently fixate the animal's head by inserting the head mounter into the port of the fixation bar. This method could be easily applicable if implantation surgery using dental acrylics is necessary and might be useful for laboratories that cannot easily fabricate CNC machined metal head-posts.

  5. Dissipation factor of acrylic dielectric elastomer--an experimental study.

    PubMed

    Sahu, Raj Kumar; Pramanik, Bipul; Patra, Karali; Bhaumik, Shovan; Pandey, Arvind Kumar; Setua, Dipak Kumar

    2014-10-01

    This paper studies the effects of frequency, pre-strain and electrode types on the dielectric property of a commercially available and most widely used acrylic elastomer, VHB 4910. The acrylic VHB film is pre-stretched in biaxial directions with the help of an in-house developed biaxial stretching device. The stretched film has been sandwiched between two card board frames to prepare samples of different pre-stretch values. Three different types of electrodes namely copper tape, silver grease and carbon grease have been pasted on the both sides of prestretched samples. Dissipation factor of pre-stretched and electrode adhered VHB sample has been experimentally determined at different frequency (upto 1 MHz) of input voltage using a LCR meter. Experimental results on the variation of dissipation factor with pre-straining, frequency (low to high) and electrode types are reported. The dissipation factor value is further used to estimate electrical efficiency at different biaxial pre-straining, frequency and electrode types.

  6. Dissociative photoionization of ethyl acrylate: Theoretical and experimental insights

    NASA Astrophysics Data System (ADS)

    Song, Yanlin; Chen, Jun; Ding, Mengmeng; Wei, Bin; Cao, Maoqi; Shan, Xiaobin; Zhao, Yujie; Huang, Chaoqun; Sheng, Liusi; Liu, Fuyi

    2015-08-01

    The photoionization and dissociation of ethyl acrylate have been investigated by time-of-flight mass spectrometer with tunable vacuum ultraviolet (VUV) source in the range of 9.0-20.0 eV. The photoionization mass spectrum (PIMS) for ethyl acrylate and photoionization efficiency (PIE) curves for its major fragment ions: C5H7O2+, C4H5O2+, C3H5O2+, C3H4O+, C3H3O+, C2H5O+, C2H3O+, C2H5+ and C2H4+ have been obtained. The formation channels of main fragments are predicted by Gaussian 09 program at G3B3 level and examined via their dissociation energies from experimental results. Based on our analysis, nine main dissociative photoionization channels are proposed: C5H7O2+ + H, C4H5O2+ + CH3, C3H5O2+ + C2H3, C3H4O+ + C2H4O, C3H3O+ + C2H5O, C2H5O+ + C3H3O, C2H3O+ + C3H5O, C2H5+ + C3H3O2, C2H4+ + C3H4O2, respectively. The results of this work lead to a better understanding of photochemistry in the environment.

  7. Color difference threshold determination for acrylic denture base resins.

    PubMed

    Ren, Jiabao; Lin, Hong; Huang, Qingmei; Liang, Qifan; Zheng, Gang

    2015-01-01

    This study aimed to set evaluation indicators, i.e., perceptibility and acceptability color difference thresholds, of color stability for acrylic denture base resins for a spectrophotometric assessing method, which offered an alternative to the visual method described in ISO 20795-1:2013. A total of 291 disk specimens 50±1 mm in diameter and 0.5±0.1 mm thick were prepared (ISO 20795-1:2013) and processed through radiation tests in an accelerated aging chamber (ISO 7491:2000) for increasing times of 0 to 42 hours. Color alterations were measured with a spectrophotometer and evaluated using the CIE L*a*b* colorimetric system. Color differences were calculated through the CIEDE2000 color difference formula. Thirty-two dental professionals without color vision deficiencies completed perceptibility and acceptability assessments under controlled conditions in vitro. An S-curve fitting procedure was used to analyze the 50:50% perceptibility and acceptability thresholds. Furthermore, perceptibility and acceptability against the differences of the three color attributes, lightness, chroma, and hue, were also investigated. According to the S-curve fitting procedure, the 50:50% perceptibility threshold was 1.71ΔE00 (r(2)=0.88) and the 50:50% acceptability threshold was 4.00 ΔE00 (r(2)=0.89). Within the limitations of this study, 1.71/4.00 ΔE00 could be used as perceptibility/acceptability thresholds for acrylic denture base resins.

  8. Wet air oxidation of epoxy acrylate monomer industrial wastewater.

    PubMed

    Yang, Shaoxia; Liu, Zhengqian; Huang, Xiaohui; Zhang, Beiping

    2010-06-15

    Epoxy acrylate monomer industrial wastewater contained highly concentrated and toxic organic compounds. The wet air oxidation (WAO) and catalytic wet air oxidation (CWAO) were used to eliminate pollutants in order to examine the feasibility of the WAO/CWAO as a pre-treatment method for the industrial wastewater. The results showed that in the WAO 63% chemical oxygen demand (COD) and 41% total organic carbon (TOC) removals were achieved and biological oxygen demand (BOD(5))/COD ratio increased from 0.13 to 0.72 after 3h reaction at 250 degrees C, 3.5MPa and the initial concentration of 100g(COD)/L. Among homogenous catalysts (Cu(2+), Fe(2+), Fe(3+) and Mn(2+) salts), Cu(2+) salt exhibited better performance. CuO catalyst was used in the CWAO of the wastewater, COD and TOC conversion were 77 and 54%, and good biodegradability was achieved. The results proved that the CWAO was an effective pre-treatment method for the epoxy acrylate monomer industrial wastewater.

  9. Graft copolymerization of acrylic acid onto polyamide fibers

    NASA Astrophysics Data System (ADS)

    Makhlouf, Chahira; Marais, Stéphane; Roudesli, Sadok

    2007-04-01

    The grafting of acrylic acid (AA) monomer (CH 2dbnd CH sbnd COOH) on polyamide 6.6 monofilaments (PA 6.6) using benzoyl peroxide (BPO) as initiator was carried out in order to enhance the hydrophilic nature of fibers. The grafting rate depends on the AA concentration, the BPO concentration, the time and the temperature of reaction. The best conditions for optimum rate of grafting were obtained with a AA concentration of 0.5 M, a BPO concentration of 0.03 M, a reaction temperature of T = 85 °C and a reaction time of 120 mn. The fiber surface has been investigated by many experimental techniques of characterization such as Fourier transform infrared spectroscopy (FTIR), calorimetric analysis (DSC), scanning electron microscopy (SEM), and contact angle measurements. The effect of grafting of acrylic acid onto PA 6.6 fibers on their moisture and mechanical resistances was analyzed from water sorption and elongation at break measurements. The analysis of the experimental data shows clearly the efficiency of the grafting reaction used, leading to a significant increase of the hydrophilic character of the PA 6.6 surface.

  10. Thin film of Poly(acrylic acid-co-allyl acrylate) as a Sacrificial Protective Layer for Hydrophilic Self Cleaning Glass

    PubMed Central

    Lejnieks, Jānis; Mourran, Ahmed; Tillmann, Walter; Keul, Helmut; Möller, Martin

    2010-01-01

    Poly(acrylic acid-co-allyl acrylate) statistical copolymers were synthesized in a controlled manner in two steps: first tert.butyl acrylate and allyl acrylate were polymerized via atom transfer radical polymerization (ATRP) and afterwords the tert.butyl protective groups were removed via hydrolysis. Samples of self cleaning glass (SCG) were coated with thin films of poly(acrylic acid-co-allyl acrylate) and cross-linked afterwards by UV irradiation (in the presence of a photoinitiator and an accelerator). Solution cast thin films were transparent and homogeneous before and after UV cross-linking. The irradiated samples were found to be hydrophilic (Θ < 20°) and water insoluble. The coating prevented the spontaneous hydrophobization of the SCG by residual silicon exhaled from the sealing material. The TiO2 photocatalyst that covers the glass surface was found to strip the protective coating. The rate of the photooxidation process was measured by IR spectroscopy. The real field performance of the protective coating was also tested.

  11. In vitro measurement of bone-acrylic interface pressure during femoral component insertion.

    PubMed

    Markolf, K L; Amstutz, H C

    1976-01-01

    Bone-acrylic interface pressure measurements were recorded at the medial interior rasped surfaces of fresh cadaver femurs during digital packing of acrylic bone cement and during insertion and seating of a Trapezoidal-28 femoral total hip component. Plugging of the femoral canal below the tip of the prosthesis stem was an effective means for increasing pressure in the distal femoral canal when the stem was inserted in the early stages of acrylic polymerization (i.e. immediately after dough time). At surgery, this can be accomplished by inserting a small bolus of acrylic down the canal to a depth below the tip of the seated stem and allowing it to polymerize in place. This forms an effective seal which prevents distal extrusion of the acrylic when the cavity is then packed prior to prosthesis insertion. Elimination of cement in the distal canal also avoids any future difficulty of acrylic removal should revision become necessary due to loosening or infection. No significant pressure differences were observed between one and two millimeter thicknesses of acrylic between the metal and bone. Interface pressures developed during finger packing were of the same order of magnitude as those achieved during seating of the femoral component. Use of a rubber diaphragm stretched tightly over the margins of the rasped femoral cavity helped to contain the acrylic and prevent extrusion during finger packing but was ineffective in increasing interface pressure. When this method is used, the acrylic can be poured or injected into the canal and packed before dough stage and thus facilitate increased cancellous penetration when the acrylic is in a state of low viscosity.

  12. Comparative evaluation of linear dimensional changes of four commercially available heat cure acrylic resins

    PubMed Central

    Arora, Saryu; Khindaria, S. K.; Garg, Sushant; Mittal, Sanjay

    2011-01-01

    Context: Heat cured acrylic resins undergo dimensional changes during polymerization. Dimensional changes which occur in the heat cure acrylic resins are shrinkage and expansion which affects the fit of the denture and occlusal relationship. Aims: The purpose of this study was to access the linear dimensional changes of four heat cure acrylic resins before and after curing and compare the changes among four different acrylic brands. Materials and Methods: Twenty four patients irrespective of age and sex were taken and four commercially available brands were procured. After the teeth arrangement on the mandibular trial denture, two pins were fixed in central fossae of first molar on both sides and one pin in the cingulum of left central incisor. Meliodent heat cure acrylic resin was used in Group A; Trevalon heat cure acrylic resin was used in Group B; Triplex heat cure acrylic resin was used in Group C and Vertex heat cure acrylic resin was used in Group D. Linear measurements of the trial wax up before and after curing and before and after finishing and polishing were measured and compared. Collected data was analyzed with analysis of variance and ‘t’ test at 95% level of confidence (P=0.05). Results: The maximum percentage changes were seen in cases of Group A (Meliodent) followed by Group B, Group C and Group D (Trevalon, Triplex and Vertex). Meliodent showed the highest percentage change i.e. 1.18% and Vertex showed least percentage change of 0.37 %. Conclusions: Shrinkage occurred after curing and after finishing and polishing, which varies significantly with the four commercially available heat cure acrylic resins. Among the four different brands of heat cure acrylic resin Group D (Vertex) had the least linear dimensional changes after curing and after finishing and polishing, so that D (Vertex) could be the material of choice for fabrication of complete denture among the four brands. PMID:22090761

  13. Investigation of X-ray fluorescence computed tomography (XFCT) and K-edge imaging.

    PubMed

    Bazalova, Magdalena; Kuang, Yu; Pratx, Guillem; Xing, Lei

    2012-08-01

    This work provides a comprehensive Monte Carlo study of X-ray fluorescence computed tomography (XFCT) and K-edge imaging system, including the system design, the influence of various imaging components, the sensitivity and resolution under various conditions. We modified the widely used EGSnrc/DOSXYZnrc code to simulate XFCT images of two acrylic phantoms loaded with various concentrations of gold nanoparticles and Cisplatin for a number of XFCT geometries. In particular, reconstructed signal as a function of the width of the detector ring, its angular coverage and energy resolution were studied. We found that XFCT imaging sensitivity of the modeled systems consisting of a conventional X-ray tube and a full 2-cm-wide energy-resolving detector ring was 0.061% and 0.042% for gold nanoparticles and Cisplatin, respectively, for a dose of ∼ 10 cGy. Contrast-to-noise ratio (CNR) of XFCT images of the simulated acrylic phantoms was higher than that of transmission K-edge images for contrast concentrations below 0.4%.

  14. Automated measurement of anterior and posterior acetabular sector angles

    NASA Astrophysics Data System (ADS)

    Ibragimov, Bulat; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2012-03-01

    In this paper, we propose a segmentation algorithm by which anatomical landmarks on the pelvis are extracted from computed tomography (CT) images. The landmarks are used to automatically define the anterior (AASA) and posterior acetabular sector angles (PASA) describing the degree of hip misalignment. The center of each femoral head is obtained by searching for the point at which most intensity gradient vectors defined at edge points intersect. The radius of each femoral head is computed by finding the sphere, positioned at the center of the femoral head, for which the normalized sum of gradient vector magnitudes on the sphere surface is maximal. The anterior and posterior corners of each acetabulum are searched for on a curve representing the acetabulum and defined by dynamic programming. The femoral head centers and anterior and posterior corners are used to calculate the AASA and PASA. The algorithm was applied to CT images of 120 normal subjects and the results were compared to ground truth values obtained by manual segmentation. The mean absolute difference (+/- standard deviation) between the obtained and ground truth values was 1.3 +/- 0.3 mm for the femoral head centers and 2.1 +/- 1.3 degrees for the acetabular angles.

  15. Reduction of airfoil trailing edge noise by trailing edge blowing

    NASA Astrophysics Data System (ADS)

    Gerhard, T.; Erbslöh, S.; Carolus, T.

    2014-06-01

    The paper deals with airfoil trailing edge noise and its reduction by trailing edge blowing. A Somers S834 airfoil section which originally was designed for small wind turbines is investigated. To mimic realistic Reynolds numbers the boundary layer is tripped on pressure and suction side. The chordwise position of the blowing slot is varied. The acoustic sources, i.e. the unsteady flow quantities in the turbulent boundary layer in the vicinity of the trailing edge, are quantified for the airfoil without and with trailing edge blowing by means of a large eddy simulation and complementary measurements. Eventually the far field airfoil noise is measured by a two-microphone filtering and correlation and a 40 microphone array technique. Both, LES-prediction and measurements showed that a suitable blowing jet on the airfoil suction side is able to reduce significantly the turbulence intensity and the induced surface pressure fluctuations in the trailing edge region. As a consequence, trailing edge noise associated with a spectral hump around 500 Hz could be reduced by 3 dB. For that a jet velocity of 50% of the free field velocity was sufficient. The most favourable slot position was at 90% chord length.

  16. Morphological changes in tibial tunnels after anatomic anterior cruciate ligament reconstruction with hamstring tendon graft.

    PubMed

    Ohori, Tomoki; Mae, Tatsuo; Shino, Konsei; Tachibana, Yuta; Sugamoto, Kazuomi; Yoshikawa, Hideki; Nakata, Ken

    2017-09-15

    Three-dimensional (3D) reconstructed computed tomography (CT) is crucial for the reliable and accurate evaluation of tunnel enlargement after anterior cruciate ligament (ACL) reconstruction. The purposes of this study were to evaluate the tibial tunnel enlargement at the tunnel aperture and inside the tunnel and to clarify the morphological change at the tunnel footprint 1 year after the anatomic triple-bundle (ATB) ACL reconstruction using 3D CT models. Eighteen patients with unilateral ACL rupture were evaluated. The ATB ACL reconstruction with a semitendinosus tendon autograft was performed. 3D computer models of the tibia and the three tibial tunnels were reconstructed from CT data obtained 3 weeks and 1 year after surgery. The cross-sectional areas (CSAs) of the two anterior and the one posterior tunnels were measured at the tunnel aperture and 5 and 10 mm distal from the aperture and compared between the two periods. The locations of the center and the anterior, posterior, medial, and lateral edges of each tunnel footprint were also measured and compared between the two periods. The CSA of the posterior tunnel was significantly enlarged at the aperture by 40.4%, whereas that of the anterior tunnels did not change significantly, although the enlargement rate was 6.1%. On the other hand, the CSA was significantly reduced at 10 mm distal from the aperture in the anterior tunnels. The enlargement rate in the posterior tunnel was significantly greater than that in the anterior tunnels at the aperture. The center of the posterior tunnel footprint significantly shifted postero-laterally. The anterior and posterior edges of the posterior tunnel footprint demonstrated a significant posterior shift, while the lateral edge significantly shifted laterally. There was no significant shift of the center or all the edges of the anterior tunnels footprint. The posterior tibial tunnel was significantly enlarged at the aperture by 40% with the morphological change in the

  17. Extradural anterior clinoidectomy. Technical note.

    PubMed

    Noguchi, Akio; Balasingam, Vijayabalan; Shiokawa, Yoshiaki; McMenomey, Sean O; Delashaw, Johnny B

    2005-05-01

    The anterior clinoid process (ACP), located on the skull base, is a relatively small structure, although its removal provides enormous gain in facilitating the management of lesions--either tumors or aneurysms--in the paraclinoid region and upper basilar artery. The extensive surgical field gained contributes to safer exposure of the neurovascular elements in the vicinity while avoiding excessive and hazardous retraction of the brain. In this report the authors present a technically simpler avenue for performing an extradural anterior clinoidectomy after reviewing the anatomy of the ACP and its anatomical variations. Additionally, the original Dolenc procedure and its subseqtient derivatives are compared and contrasted to the authors' simpler and less laborious technique. Different clinical situations in which to use the procedure are described based on the authors' experience from 60 cases (40 aneurysm cases and 20 tumor cases) during a 4-year period.

  18. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it...

  19. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  20. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  1. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  2. 38 CFR 3.379 - Anterior poliomyelitis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Anterior poliomyelitis. 3... Specific Diseases § 3.379 Anterior poliomyelitis. If the first manifestations of acute anterior poliomyelitis present themselves in a veteran within 35 days of termination of active military service, it is...

  3. Proptosis and Anterior Dislocation as a Late Noninflammatory Complication of Failure of Tissue Integration in the Alphasphere Implant.

    PubMed

    Neimkin, Michael G; Reggie, Sara; Holds, John B

    2016-01-04

    A 57-year-old healthy female underwent enucleation for choroidal melanoma with primary implantation of a 2-hydroxyethyl methacrylate sphere (AlphaSphere, Addition Technology, Des Plaines, IL). Her course was uneventful, with successful prosthetic fitting 6 weeks postoperatively. She returned 2 years later, with anterior displacement of the implant, poor implant movement, and poor prosthetic fit. There was no defect in the conjunctiva, Tenon's layer or evidence of inflammation. Successful orbital implant exchange was performed, replacing the AlphaSphere with an eyebank-scleral wrapped acrylic implant. Intraoperative findings revealed dissolution of the scaffolding aspect of the anterior implant, with loss of extraocular muscle attachments and no fibrovascular ingrowth. This case demonstrates late AlphaSphere failure in an otherwise unremarkable course; further review of similar cases or a larger study is warranted to examine the efficacy of this relatively new implant.

  4. Production of anterior segment ischemia.

    PubMed Central

    Hiatt, R L

    1977-01-01

    Anterior segment ischemic changes can occur without detachment of any muscles. The most common cause of such ischemic changes of the anterior segment is the removal of too many rectus muscles in one operation. Twenty dog eyes and eight monkey eyes were subjected to the disinsertion and detachment of various combinations of extraocular muscles. The dogs were sacrificed at intervals from 30 to 90 days. During the observation period, they were observed for gross and slit-lamp changes. The enucleated eyes were studied microscopically for signs of ischemic and necrotic changes. Two patients who were studied, observed, and treated for anterior segment ischemia following muscle surgery are described. The changes which occur after extraocular muscle surgery are extensive and include corneal edema, cataract, chemosis, corneal changes, decreases in intraocular pressure, decreases in outflow or glaucoma, and frank necrosis. The variables which lead to this reaction are described in detail. Also, some unanswered queries, such as the duration of the reaction and the time interval of the reaction after multiple muscle operations are discussed. Images FIGURE 1 A FIGURE 1 B FIGURE 1 C FIGURE 2 A FIGURE 2 B FIGURE 2 C FIGURE 2 D FIGURE 3 FIGURE 4 PMID:418549

  5. Erectile function after anterior urethroplasty.

    PubMed

    Coursey, J W; Morey, A F; McAninch, J W; Summerton, D J; Secrest, C; White, P; Miller, K; Pieczonka, C; Hochberg, D; Armenakas, N

    2001-12-01

    We ascertained the impact of anterior urethroplasty on male sexual function. A validated questionnaire was mailed to 200 men who underwent anterior urethroplasty to evaluate postoperative sexual function. Questions addressed the change in erect penile length and angle, patient satisfaction with erection, preoperative and postoperative coital frequency, and change in erection noted by the sexual partner. Results were stratified by the urethral reconstruction method, namely anastomosis, buccal mucosal graft, penile flap and all others, and compared with those in a similar group of men who underwent circumcision only. Of the 200 men who underwent urethroplasty 152 who were 17 to 83 years old (mean age 45.7) completed the questionnaire. Average followup was 36 months (range 3 to 149). Overall there was a similar incidence of sexual problems after urethroplasty and circumcision. Penile skin flap urethroplasty was associated with a slightly higher incidence of impaired sexual function than other procedures (p >0.05). Men with a longer stricture were most likely to report major changes in erectile function and penile length (p <0.05) but improvement was evident with time in 61.8%. Overall anterior urethral reconstruction appears no more likely to cause long-term postoperative sexual dysfunction than circumcision. Men with a long stricture may be at increased risk for transient erectile changes.

  6. Oscillations at B Ring Edge

    NASA Image and Video Library

    2010-11-01

    This image obtained by NASA Cassini spacecraft of the outer edge of Saturn?s B ring, reveals the combined effects of a tugging moon and oscillations that can naturally occur in disks like Saturn rings and spiral galaxies.

  7. Fast tracking using edge histograms

    NASA Astrophysics Data System (ADS)

    Rokita, Przemyslaw

    1997-04-01

    This paper proposes a new algorithm for tracking objects and objects boundaries. This algorithm was developed and applied in a system used for compositing computer generated images and real world video sequences, but can be applied in general in all tracking systems where accuracy and high processing speed are required. The algorithm is based on analysis of histograms obtained by summing along chosen axles pixels of edge segmented images. Edge segmentation is done by spatial convolution using gradient operator. The advantage of such an approach is that it can be performed in real-time using available on the market hardware convolution filters. After edge extraction and histograms computation, respective positions of maximums in edge intensity histograms, in current and previous frame, are compared and matched. Obtained this way information about displacement of histograms maximums, can be directly converted into information about changes of target boundaries positions along chosen axles.

  8. Edge Fracture in Complex Fluids

    NASA Astrophysics Data System (ADS)

    Hemingway, Ewan J.; Kusumaatmaja, Halim; Fielding, Suzanne M.

    2017-07-01

    We study theoretically the edge fracture instability in sheared complex fluids, by means of linear stability analysis and direct nonlinear simulations. We derive an exact analytical expression for the onset of edge fracture in terms of the shear-rate derivative of the fluid's second normal stress difference, the shear-rate derivative of the shear stress, the jump in shear stress across the interface between the fluid and the outside medium (usually air), the surface tension of that interface, and the rheometer gap size. We provide a full mechanistic understanding of the edge fracture instability, carefully validated against our simulations. These findings, which are robust with respect to choice of rheological constitutive model, also suggest a possible route to mitigating edge fracture, potentially allowing experimentalists to achieve and accurately measure flows stronger than hitherto possible.

  9. Edge Fracture in Complex Fluids.

    PubMed

    Hemingway, Ewan J; Kusumaatmaja, Halim; Fielding, Suzanne M

    2017-07-14

    We study theoretically the edge fracture instability in sheared complex fluids, by means of linear stability analysis and direct nonlinear simulations. We derive an exact analytical expression for the onset of edge fracture in terms of the shear-rate derivative of the fluid's second normal stress difference, the shear-rate derivative of the shear stress, the jump in shear stress across the interface between the fluid and the outside medium (usually air), the surface tension of that interface, and the rheometer gap size. We provide a full mechanistic understanding of the edge fracture instability, carefully validated against our simulations. These findings, which are robust with respect to choice of rheological constitutive model, also suggest a possible route to mitigating edge fracture, potentially allowing experimentalists to achieve and accurately measure flows stronger than hitherto possible.

  10. Edge equilibrium code for tokamaks

    SciTech Connect

    Li, Xujing; Drozdov, Vladimir V.

    2014-01-15

    The edge equilibrium code (EEC) described in this paper is developed for simulations of the near edge plasma using the finite element method. It solves the Grad-Shafranov equation in toroidal coordinate and uses adaptive grids aligned with magnetic field lines. Hermite finite elements are chosen for the numerical scheme. A fast Newton scheme which is the same as implemented in the equilibrium and stability code (ESC) is applied here to adjust the grids.

  11. Immediate loading of subcrestally placed dental implants in anterior and premolar sites.

    PubMed

    Henningsen, Anders; Smeets, Ralf; Köppen, Kai; Sehner, Susanne; Kornmann, Frank; Gröbe, Alexander; Heiland, Max; Gerlach, Till

    2017-08-23

    Immediate loading of dental implants has been evolving into an appropriate procedure for the treatment of partially edentulous jaws. The purpose of this study was to evaluate the clinical success and radiological outcome of immediately and delayed loaded dental implants in anterior and premolar sites. In this retrospective study, data of 163 individuals requiring tooth removal with subsequent implant placement in anterior and premolar sites were analyzed. Implants were immediately loaded by provisional acrylic resin bridges or loaded with delay. Implants were followed up annually for up to 9 years including intraoral radiographs. A total of 285 implants in 163 patients were placed. 218 implants were immediately loaded and 67 implants with delay. Fifteen implants failed during the follow-up period resulting in survival rates of 94.5% for immediate loading and 95.5% for delayed loading. After an initial decrease of 0.3 mm in the first 12 months the marginal bone level remained stable. No statistically significant differences were found in marginal bone loss between immediately and delayed loaded implants (P = 0.518, 95% CI). Within the limits of this study, immediate loading of immediately subcrestally placed dental implants in anterior and premolar sites is a reliable treatment option for dental rehabilitation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Improvement of Uveal and Capsular Biocompatibility of Hydrophobic Acrylic Intraocular Lens by Surface Grafting with 2-Methacryloyloxyethyl Phosphorylcholine-Methacrylic Acid Copolymer

    PubMed Central

    Tan, Xuhua; Zhan, Jiezhao; Zhu, Yi; Cao, Ji; Wang, Lin; Liu, Sa; Wang, Yingjun; Liu, Zhenzhen; Qin, Yingyan; Wu, Mingxing; Liu, Yizhi; Ren, Li

    2017-01-01

    Biocompatibility of intraocular lens (IOL) is critical to vision reconstruction after cataract surgery. Foldable hydrophobic acrylic IOL is vulnerable to the adhesion of extracellular matrix proteins and cells, leading to increased incidence of postoperative inflammation and capsule opacification. To increase IOL biocompatibility, we synthesized a hydrophilic copolymer P(MPC-MAA) and grafted the copolymer onto the surface of IOL through air plasma treatment. X-ray photoelectron spectroscopy, atomic force microscopy and static water contact angle were used to characterize chemical changes, topography and hydrophilicity of the IOL surface, respectively. Quartz crystal microbalance with dissipation (QCM-D) showed that P(MPC-MAA) modified IOLs were resistant to protein adsorption. Moreover, P(MPC-MAA) modification inhibited adhesion and proliferation of lens epithelial cells (LECs) in vitro. To analyze uveal and capsular biocompatibility in vivo, we implanted the P(MPC-MAA) modified IOLs into rabbits after phacoemulsification. P(MPC-MAA) modification significantly reduced postoperative inflammation and anterior capsule opacification (ACO), and did not affect posterior capsule opacification (PCO). Collectively, our study suggests that surface modification by P(MPC-MAA) can significantly improve uveal and capsular biocompatibility of hydrophobic acrylic IOL, which could potentially benefit patients with blood-aqueous barrier damage. PMID:28084469

  13. Gel polymer electrolytes based on nanofibrous polyacrylonitrile–acrylate for lithium batteries

    SciTech Connect

    Kim, Dul-Sun; Woo, Jang Chang; Youk, Ji Ho; Manuel, James; Ahn, Jou-Hyeon

    2014-10-15

    Graphical abstract: - Highlights: • Nanofibrous polyacrylonitrile–acrylate membranes were prepared by electrospinning. • Trimethylolpropane triacrylate was used as a crosslinking agent of fibers. • The GPE based on PAN–acrylate (1/0.5) showed good electrochemical properties. - Abstract: Nanofibrous membranes for gel polymer electrolytes (GPEs) were prepared by electrospinning a mixture of polyacrylonitrile (PAN) and trimethylolpropane triacrylate (TMPTA) at weight ratios of 1/0.5 and 1/1. TMPTA is used to achieve crosslinking of fibers thereby improving mechanical strength. The average fiber diameters increased with increasing TMPTA concentration and the mechanical strength was also improved due to the enhanced crosslinking of fibers. GPEs based on electrospun membranes were prepared by soaking them in a liquid electrolyte of 1 M LiPF{sub 6} in ethylene carbonate (EC)/dimethyl carbonate (DMC) (1:1, v/v). The electrolyte uptake and ionic conductivity of GPEs based on PAN and PAN–acrylate (weight ratio; 1/1 and 1/0.5) were investigated. Ionic conductivity of GPEs based on PAN–acrylate was the highest for PAN/acrylate (1/0.5) due to the proper swelling of fibers and good affinity with liquid electrolyte. Both GPEs based on PAN and PAN–acrylate membranes show good oxidation stability, >5.0 V vs. Li/Li{sup +}. Cells with GPEs based on PAN–acrylate (1/0.5) showed remarkable cycle performance with high initial discharge capacity and low capacity fading.

  14. An ORMOSIL-Containing Orthodontic Acrylic Resin with Concomitant Improvements in Antimicrobial and Fracture Toughness Properties

    PubMed Central

    Rueggeberg, Frederick A.; Niu, Li-na; Mettenberg, Donald; Yiu, Cynthia K. Y.; Blizzard, John D.; Wu, Christine D.; Mao, Jing; Drisko, Connie L.; Pashley, David H.; Tay, Franklin R.

    2012-01-01

    Global increase in patients seeking orthodontic treatment creates a demand for the use of acrylic resins in removable appliances and retainers. Orthodontic removable appliance wearers have a higher risk of oral infections that are caused by the formation of bacterial and fungal biofilms on the appliance surface. Here, we present the synthetic route for an antibacterial and antifungal organically-modified silicate (ORMOSIL) that has multiple methacryloloxy functionalities attached to a siloxane backbone (quaternary ammonium methacryloxy silicate, or QAMS). By dissolving the water-insoluble, rubbery ORMOSIL in methyl methacrylate, QAMS may be copolymerized with polymethyl methacrylate, and covalently incorporated in the pressure-processed acrylic resin. The latter demonstrated a predominantly contact-killing effect on Streptococcus mutans ATCC 36558 and Actinomyces naselundii ATCC 12104 biofilms, while inhibiting adhesion of Candida albicans ATCC 90028 on the acrylic surface. Apart from its favorable antimicrobial activities, QAMS-containing acrylic resins exhibited decreased water wettability and improved toughness, without adversely affecting the flexural strength and modulus, water sorption and solubility, when compared with QAMS-free acrylic resin. The covalently bound, antimicrobial orthodontic acrylic resin with improved toughness represents advancement over other experimental antimicrobial acrylic resin formulations, in its potential to simultaneously prevent oral infections during appliance wear, and improve the fracture resistance of those appliances. PMID:22870322

  15. Solvent effects on acrylate kp in organic media?-A systematic PLP-SEC study.

    PubMed

    Haehnel, Alexander P; Wenn, Benjamin; Kockler, Katrin; Bantle, Tobias; Misske, Andrea M; Fleischhaker, Friederike; Junkers, Thomas; Barner-Kowollik, Christopher

    2014-12-01

    The Arrhenius parameters of the propagation rate coefficient, kp , are determined employing high-frequency pulsed laser polymerization-size exclusion chromatography (PLP-SEC) for the homologous series of five linear alkyl acrylates (i.e., methyl acrylate (MA), butyl acrylate (BA), dodecyl acrylate (DA), stearyl acrylate (SA), and behenyl acrylate (BeA)) in 1 m solution in butyl acetate (BuAc) as well as in toluene. The comparison of the obtained kp values with the literature known values for bulk demonstrates that no significant solvent influence neither in BuAc nor in toluene on the propagation reaction compared to bulk is detectable. Concomitantly, the kp values in toluene and in BuAc solution display a similar increase with increasing number of C-atoms in the ester side chain as was previously reported for the bulk systems. These findings are in clear contrast to earlier studies, which report a decrease of kp with increasing ester side chain length in toluene. The additional investigation of the longest and shortest ester side chain acrylate (i.e., BeA and MA) over the entire experimentally available concentration range at one temperature (i.e., 50 °C) does not reveal any general concentration dependence and all observed differences in the kp are within the experimental error. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Antimicrobial activity of a quaternary ammonium methacryloxy silicate-containing acrylic resin: a randomised clinical trial

    PubMed Central

    Liu, Si-ying; Tonggu, Lige; Niu, Li-na; Gong, Shi-qiang; Fan, Bing; Wang, Liguo; Zhao, Ji-hong; Huang, Cui; Pashley, David H.; Tay, Franklin R.

    2016-01-01

    Quaternary ammonium methacryloxy silicate (QAMS)-containing acrylic resin demonstrated contact-killing antimicrobial ability in vitro after three months of water storage. The objective of the present double-blind randomised clinical trial was to determine the in vivo antimicrobial efficacy of QAMS-containing orthodontic acrylic by using custom-made removable retainers that were worn intraorally by 32 human subjects to create 48-hour multi-species plaque biofilms, using a split-mouth study design. Two control QAMS-free acrylic disks were inserted into the wells on one side of an orthodontic retainer, and two experimental QAMS-containing acrylic disks were inserted into the wells on the other side of the same retainer. After 48 hours, the disks were retrieved and examined for microbial vitality using confocal laser scanning microscopy. No harm to the oral mucosa or systemic health occurred. In the absence of carry-across effect and allocation bias (disks inserted in the left or right side of retainer), significant difference was identified between the percentage kill in the biovolume of QAMS-free control disks (3.73 ± 2.11%) and QAMS-containing experimental disks (33.94 ± 23.88%) retrieved from the subjects (P ≤ 0.001). The results validated that the QAMS-containing acrylic exhibits favourable antimicrobial activity against plaque biofilms in vivo. The QAMS-containing acrylic may also be used for fabricating removable acrylic dentures. PMID:26903314

  17. Effect of thermal cycling and disinfection on microhardness of acrylic resin denture base.

    PubMed

    Goiato, Marcelo Coelho; Dos Santos, Daniela Micheline; Baptista, Gabriella Trunckle; Moreno, Amália; Andreotti, Agda Marobo; Dekon, Stéfan Fiuza de Carvalho

    2013-04-01

    The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins.

  18. Facile Fabrication of Gradient Surface Based on (meth)acrylate Copolymer Films

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Yang, H.; Wen, X.-F.; Cheng, J.; Xiong, J.

    2016-08-01

    This paper describes a simple and economic approach for fabrication of surface wettability gradient on poly(butyl acrylate - methyl methacrylate) [P (BA-MMA)] and poly(butyl acrylate - methyl methacrylate - 2-hydroxyethyl methacrylate) [P (BA-MMA-HEMA)] films. The (meth)acrylate copolymer [including P (BA-MMA) and P (BA-MMA-HEMA)] films are hydrolyzed in an aqueous solution of NaOH and the transformation of surface chemical composition is achieved by hydrolysis in NaOH solution. The gradient wetting properties are generated based on different functional groups on the P (BA-MMA) and P (BA-MMA-HEMA) films. The effects of both the surface chemical and surface topography on wetting of the (meth)acrylate copolymer film are discussed. Surface chemical composition along the materials length is determined by XPS, and surface topography properties of the obtained gradient surfaces are analyzed by FESEM and AFM. Water contact angle system (WCAs) results show that the P (BA-MMA-HEMA) films provide a larger slope of the gradient wetting than P (BA-MMA). Moreover, this work demonstrates that the gradient concentration of chemical composition on the poly(meth) acrylate films is owing to the hydrolysis processes of ester group, and the hydrolysis reactions that have negligible influence on the surface morphology of the poly(meth) acrylate films coated on the glass slide. The gradient wettability surfaces may find broad applications in the field of polymer coating due to the compatibility of (meth) acrylate polymer.

  19. [Determination of acrylic acid from catalytic preparation lactic acid by anion-exchange chromatography].

    PubMed

    Shi, Haining; Wang, Hui; Tao, Lizhi; Wang, Zonghua; Ding, Mingyu

    2010-06-01

    Acrylic acid is a kind of important monomer and basic organic chemical raw material. In the process of catalytic preparation of acrylic acid from lactic acid, in order to monitor the catalytic process effectively and timely, an anion-exchange chromatographic (AEC) method has been established for the simultaneous determination of lactic acid and acrylic acid. The separation was carried out on a Metrohm A Supp 5 anion-exchange column (150 mm x 4.0 mm) with 2 mmol/L Na2CO3 +2 mmol/L NaHCO3 as the mobile phase. The flow rate of the mobile phase was 0.7 mL/min. A chemically suppressed conductivity detector was used. The linear ranges of calibration curves were 0.1-500 mg/L for lactic acid and 0.1-200 mg/L for acrylic acid. The detection limits with S/N = 3 were 0.030 mg/L for lactic acid and 0. 035 mg/L for acrylic acid. The recoveries of lactic acid and acrylic acid were 100.7%-106% and 99.6%-103% with the relative standard deviations of 2.16%-2.49% and 2.42%-2.48%, respectively. This method is accurate, speedy, sensitive and reproducible, and has been successfully used for the determination of lactic acid and acrylic acid in the catalytic reaction product.

  20. The photocatalytic enhancement of acrylic and PET solar water disinfection (SODIS) bottles.

    PubMed

    Carey, J M; Perez, T M; Arsiaga, E G; Loetscher, L H; Boyd, J E

    2011-01-01

    The solar water disinfection method (SODIS) was modified by the addition of a photocatalytic layer of titania on the interior surface of polyethylene terephthalate (PET) and acrylic bottles. Titania was solvent deposited on the interior of commercially available PET bottles, as well as bottles that were constructed from acrylic. Uncoated and titania-coated acrylic bottles removed 3,000,000-5,000,000 colony forming units per milliliter of K12 E. coli from 670 mL of contaminated water in 40 min of solar irradiance. After five hours of sunlight exposure, the concentration of 10 ppm methyl orange (a representative organic water contaminant), was reduced by 61% using the titania-coated acrylic bottles. The concentration of 87 ppb microcystin-LR (a representative algal toxin) was reduced by 70% after 7 hours of sunlight exposure in the titania-coated acrylic bottles. Acrylic is an effective alternative to PET for use in the SODIS method due to its greater UV transparency. The addition of titania to PET and acrylic bottles confers the ability to remove chemical contaminants in addition to inactivating microbiological contaminants.

  1. Edge instabilities of topological superconductors

    NASA Astrophysics Data System (ADS)

    Hofmann, Johannes S.; Assaad, Fakher F.; Schnyder, Andreas P.

    2016-05-01

    Nodal topological superconductors display zero-energy Majorana flat bands at generic edges. The flatness of these edge bands, which is protected by time-reversal and translation symmetry, gives rise to an extensive ground-state degeneracy. Therefore, even arbitrarily weak interactions lead to an instability of the flat-band edge states towards time-reversal and translation-symmetry-broken phases, which lift the ground-state degeneracy. We examine the instabilities of the flat-band edge states of dx y-wave superconductors by performing a mean-field analysis in the Majorana basis of the edge states. The leading instabilities are Majorana mass terms, which correspond to coherent superpositions of particle-particle and particle-hole channels in the fermionic language. We find that attractive interactions induce three different mass terms. One is a coherent superposition of imaginary s -wave pairing and current order, and another combines a charge-density-wave and finite-momentum singlet pairing. Repulsive interactions, on the other hand, lead to ferromagnetism together with spin-triplet pairing at the edge. Our quantum Monte Carlo simulations confirm these findings and demonstrate that these instabilities occur even in the presence of strong quantum fluctuations. We discuss the implications of our results for experiments on cuprate high-temperature superconductors.

  2. Tensile strength and impact strength of color modified acrylic resin reinforced with titanium dioxide nanoparticles.

    PubMed

    Ghahremani, Loghman; Shirkavand, Saeed; Akbari, Faezeh; Sabzikari, Niloofar

    2017-05-01

    Poor mechanical properties are among the main limitations of acrylic resins. Addition of titanium dioxide (TiO2) nanoparticles to acrylic resin has been shown to improve its mechanical properties with an adverse effect on its color. Thus, this study sought to assess the tensile and impact strength of a color modified heat cure acrylic resin reinforced with TiO2 nanoparticles. In this in vitroexperimental study, 1wt% TiO2 nanoparticles were added to SR Triplex Hot heat-cure acrylic resin powder and mixed. Pigments and color fibers were also added and 18 samples were fabricated of this paste for tensile and impact strength testing (n=9) according to ISO5271. Eighteen control samples were also fabricated from the acrylic powder without any modification. Independent t-test was used for data analysis (P< 0.05). The mean tensile strength of the reinforced group was found to be significantly higher (difference of 11 MPa) than that of the control group (P=0.001). The mean impact strength of the reinforced group was 7 MPa higher than that of the control group and this difference was statistically significant as well (P=0.001). The color modified acrylic resin reinforced with 1wt% TiO2 showed significantly higher tensile and impact strength compared to the conventional acrylic resin. Thus, TiO2 nanoparticles may be incorporated into color-modified acrylic resin powder to enhance its tensile and impact strength, given that they have no adverse effect on other properties. Key words:Tensile strength, acrylic resins, titanium dioxide, impact strength.

  3. Chain Transfer of Vegetable Oil Macromonomers in Acrylic Solution Copolymerization

    SciTech Connect

    Black, Micah; Messman, Jamie M; Rawlins, James

    2011-01-01

    Use of vegetable oil macromonomers (VOMMs) as comonomers in emulsion polymerization enables good film coalescence without the addition of solvents that constitute volatile organic compounds (VOCs). VOMMs are derived from renewable resources and offer the potential of post-application crosslinking via auto-oxidation. However, chain transfer reactions of VOMMs with initiator and/or polymer radicals during emulsion polymerization reduce the amount of allylic hydrogen atoms available for primary auto-oxidation during drying. Vegetable oils and derivatives were reacted in combination with butyl acrylate and methyl methacrylate via solution polymerization. The copolymerization was monitored using in situ infrared spectroscopy to determine the extent of chain transfer. 1H NMR spectroscopy was used to determine the loci of chain transfer and the molecular weight characteristics of the polymers were characterized by SEC. Solution polymerization was utilized to minimize temperature fluctuations and maintain polymer solubility during the initial characterization.

  4. Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses.

    PubMed

    Dai, Yunhai; Huang, Yusen; Liu, Ting; Xie, Lixin

    2014-06-01

    Two three-piece hydrophobic acrylic intraocular lenses (IOLs) were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to their opacified IOLs. In addition to light microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, confocal laser scanning microscopy was used for the first time to observe the explanted IOLs. The clinical aspect seemed to correspond to the phenomenon of surface light scattering, while laboratory analyses showed dense glistenings in the central layer of the IOL optic, which had no change next to the surface. Further studies on these phenomena are needed.

  5. Photoinduced Acrylate Polymerization: Unexpected Reduction in Chain Branching.

    PubMed

    Wenn, Benjamin; Reekmans, Gunter; Adriaensens, Peter; Junkers, Thomas

    2015-08-01

    The branching stemming from midchain radical formation in n-butyl acrylate polymerization is investigated via melt-state (13) C NMR measurements. The dependence of the degree of branching (DB) on the monomer conversion of the system is examined for photoinduced polymerizations, revealing a steady increase in branching with conversion. For polymerization at moderate light intensities, an increase in branching from 0.03% to 0.37% is observed for polymerizations at 60 °C, which is fivefold below the level of branching observed in thermally initiated polymerizations under otherwise identical reaction conditions. The reason for this overall reduction in branching remains momentarily unclear; yet, a strong dependence of branching on light intensity is observed. While polymerization under a 1 W LED lamp results at almost full monomer conversion in branching degrees of 0.22%, polymerization under a 400 W lamp yields 1.81% of chain branches.

  6. Photovoltaic lifetime and degradation science statistical pathway development: acrylic degradation

    NASA Astrophysics Data System (ADS)

    Bruckman, Laura S.; Wheeler, Nicholas R.; Kidd, Ian V.; Sun, Jiayang; French, Roger H.

    2013-09-01

    In order to optimize and extend the life of photovoltaics (PV) modules, scienti c and mechanistic statistical analytics must be performed on a large sample of materials, components and systems. Statistically signi - cant relationships were investigated between di erent mechanistically based variables to develop a statistical pathway diagram for the degradation of acrylic that is important in concentrating photovoltaics. The statisti- cally signi cant relationships were investigated using lifetime and degradation science using a domain knowledge semi-supervised generalized structural equation modeling (semi-gSEM. Predictive analytics and prognostics are informed from the statistical pathway diagram in order to predictively understand the lifetime of PV modules in di erent stress conditions and help with these critical lifetime technologies.

  7. Anomalous χ for Polydisperse Polystyrene-b-Poly(octyl acrylate)

    NASA Astrophysics Data System (ADS)

    Lee, Jumi; Ahn, Hyungju; Ryu, Du Yeol; Shin, Kwanwoo; Cho, Junhan

    2012-02-01

    We have performed small-angle neutron scattering (SANS) measurements on a disordered block copolymer from deuterated polystyrene (dPS) and self-adhesive poly(octyl acrylate) (POA) in order to elicit the effective Flory-Huggins χ, which carries the essence of the copolymer phase behavior. The sample for the measurement was prepared by blending two polydisperse dPS-b-POAs of different molecular weights for the purpose of adjusting the average size to a proper value. The SANS profiles for the copolymer were fitted to Leibler's scattering function for a polydisperse copolymer system described by Schulz-Zimm distribution. It was shown that the resultant χ as a function of inverse temperature has a strong entropic contribution and a weak enthalpic contribution. By adopting a simple analysis for specific interactions, it was found that the entropically dominated χ for dPS-b-POA arises from the steric hindrance of long alkyl side groups of POA.

  8. Mechanical performance of acrylic bone cements containing different radiopacifying agents.

    PubMed

    Ginebra, M P; Albuixech, L; Fernández-Barragán, E; Aparicio, C; Gil, F J; San, Román J; Vázquez, B; Planell, J A

    2002-04-01

    The effect that three different radiopacifying agents, two of them inorganic (BaSO4, ZrO2) and one organic (an iodine containing monomer, IHQM) have on the static and dynamic mechanical properties of acrylic bone cements was studied. Compressive and tensile strength, fracture toughness and fatigue crack propagation were evaluated. The effect of the inorganic fillers depends on their size and morphology. In relation to the radiolucent cement, the addition of zirconium dioxide improved significantly the tensile strength, the fracture toughness and the fatigue crack propagation resistance. In contrast, the addition of barium sulphate produced a decrease of the tensile strength, but did not affect the fracture toughness and improved the crack propagation resistance. When the iodine containing monomer was used, although the tensile strength and the fracture toughness increased, the fatigue crack propagation resistance remained as low as it was for the radiolucent cement.

  9. Water absorbency of chitosan grafted acrylic acid hydrogels

    NASA Astrophysics Data System (ADS)

    Astrini, N.; Anah, L.; Haryono, A.

    2017-07-01

    Acrylic acid (AA) monomer was directly grafted onto chitosan (CTS) using potassium persulfate (KPS) as an initiator and methylenebisacrylamide (MBA) as a crosslinking agent under an inert atmosphere. One factor affecting the swelling capacity of the obtained hydrogel, KPS concentration, were studied. The hydrogel products were characterized using Fourier Transform Infrared spectroscopy (FTIR) for chemical structure and scanning electron microscopy (SEM) for morphology. Swelling of the hydrogel samples in distilled water and saline solution ( 9% NaCl ) was examined. Swelling capacity of the CTS-g-PAA hydrogels in distilled water (88.53 g/g) was higher than in NaCl solution (29.94 g/g) The highest swelling capacity value was obtained when the grafted reaction was carried out using 2.5wt% initiator

  10. Methyl (E)-3-(2-formyl-phen-oxy)acrylate.

    PubMed

    Karthikeyan, S; Sethusankar, K; Selvakumar, R; Bakthadoss, M

    2014-06-01

    In the title compound, C11H10O4, the methyl acrylate sub-stituent adopts an extended E conformation with all torsion angles close to 180°. The conformation of the keto group with respect to the olefinic double bond is typically S-trans. In the crystal, mol-ecules are linked via pairs of C-H⋯O hydrogen bonds, forming inversion dimers with an R 2 (2)(8) graph-set motif. The dimers are further linked via C-H⋯O hydrogen bonds, forming chains along [001], which enclose R 3 (2)(16) graph-set ring motifs. The keto group O atomaccepts two C-H⋯O interactions.

  11. [The biomechanical behaviour of the flexible acrylic partial prosthetics].

    PubMed

    Gheban, E; Forna, Norina Consuela

    2008-01-01

    The simulation methods constitute a modern method absolutely necessary at the forerunner stage of the practical unwinding of the research stages, outlining the precise directions for the practical application, the final results influencing the dental practice. Our study proposes itself to analyze through the method of the finite element the status of the tension and the deformations registered at the level of the partially extended indentured prosthetic field and at the level of the partially flexible acrylic prosthetics. The first step was constituted by the realization of CT followed by their scanning and the usage of the material constants. Following the tomographic computer exam at the patients submitted to the study, it was observed a resorption and an important atrophy at the level of the jaw indented crest, after a period of four months, with the flexible prosthetics type Valplast, this aspect having profound clinical and viability implications to the selected therapy solution. For the 3D reconstruction of the different types of partial extended indentation the Amira universal program was used for the 3D reconstructions for any type of Tomographic Computer. Following the 3D reconstructions of the information obtained on the tomographic computer on the images it can be observed an important resorption of the jaw bone in the area of the edentulous space with an acrylic flexible prosthetics. The intrusion of the silicon material Rubber type, as a viable solution for the reduction of the absorption rate and atrophy of the partially indented prosthetics field, has results proportional to the type of the force applied and the applying of this. The simulation of the real clinical situations following the contribution of the tomographic computer constitutes a highly important stage in the evaluation of the degree of resorption and atrophy at the level of the indented crests, process whose parameters are influenced by the factorial accumulation with a profound impact

  12. Radiation-induced grafting of acrylic acid onto polyethylene filaments

    NASA Astrophysics Data System (ADS)

    Kaji, K.; Okada, T.; Sakurada, I.

    Radiation-induced grafting of acrylic acid onto high density polyethylene (PE) filaments was carried out in order to raise softening temperature and impart flame retardance and hydrophilic properties. Mutual γ-irradiation method was employed for the grafting in a mixture of acrylic acid (AA), ethylene dichloride and water containing a small amount of ferrous ammonium sulfate. The rate of grafting was very low at room temperature. On the other hand, large percent grafts were obtained when the grafting was performed at an elevated temperature. Activation energy for the initial rate of grafting was found to be 17 {kcal}/{mol} between 20 and 60°C and 10 {kcal}/{mol} between 60 and 80°C. Original PE filament begins to shrink at 70°C, show maximum shrinkage of 50% at 130°C and then breaks off at 136°C. When a 34% AA graft is converted to metallic salt such as sodium and calcium, the graft filament retains its filament form even above 300°C and gives maximum shrinkage of 15%. Burning tests by a wire-netting basket method indicate that graft filaments and its metallic salts do not form melting drops upon burning and are self-extinguishing. Original PE filament shows no moisture absorption, however, that of AA-grafted PE increases with increasing graft percent. The sodium salt of 15% graft shows the same level of moisture regain as cotton. The AA-grafted PE filament and its metallic salts can be dyed with cationic dyes even at 1% graft. Tensile properties of PE filament is impaired neither by grafting nor by conversion to metallic salts.

  13. Use of anterior maxillary distraction osteogenesis in two cleft lip and palate patients

    PubMed Central

    Srivastava, Dhirendra; Ghassemi, Alireza; Ghassemi, Mehrangiz; Showkatbakhsh, Rahman; Jamilian, Abdolreza

    2015-01-01

    Distraction osteogenesis (DO) has become a mainstream surgical technique for patients with jaw deformities. The aim of this study was to report the effect of DO done by a hyrax screw incorporated in an acrylic plate in the treatment of two maxillary deficient cases with cleft lip and palate. Two patients, a 24-year-old female and a 29-year-old male who suffered from maxillary deficiency and cleft lip and palate, were treated by DO. After making vertical cuts between the premolars on both sides and horizontal cuts similar to Le Fort 1, a hyrax screw was mounted on an acrylic plate for the slow anteroposterior expansion of maxillary arch. The expansion was achieved by turning the hyrax screw 0.8 mm per day after the latency period. Treatment was discontinued after achieving satisfactory over jet and occlusion. This study showed that anterior maxillary distraction is a reliable technique for correction of midfacial deformity arising out of cleft lip and palate. Incidences of complications are negligible compared to total maxillary distraction. PMID:26668459

  14. A Machine Vision Quality Control System for Industrial Acrylic Fibre Production

    NASA Astrophysics Data System (ADS)

    Heleno, Paulo; Davies, Roger; Correia, Bento A. Brázio; Dinis, João

    2002-12-01

    This paper describes the implementation of INFIBRA, a machine vision system used in the quality control of acrylic fibre production. The system was developed by INETI under a contract with a leading industrial manufacturer of acrylic fibres. It monitors several parameters of the acrylic production process. This paper presents, after a brief overview of the system, a detailed description of the machine vision algorithms developed to perform the inspection tasks unique to this system. Some of the results of online operation are also presented.

  15. Impression techniques for multiple implants: a photoelastic analysis. Part II: comparison of four acrylic resins.

    PubMed

    Lopes-Júnior, Itamar; de Lima Lucas, Barbara; Gomide, Henner Alberto; Gomes, Vanderlei Luiz

    2013-10-01

    Four commercial brands of chemically activated acrylic resin were compared through photoelastic analysis. Photoelastic resin blocks were made with 2 implants placed parallel to each other and 2 square transfer copings splinted. Both transfers were splinted with chemically activated acrylic resin: Dencrilay, Duralay I, Duralay II, and GC. Data were analyzed by 2-way analysis of variance and Tukey test (P < .05). Statistically significant differences were found among the 3 brands of chemically activated acrylic resin. Dencrilay showed greater dimensional alteration. Duralay I and GC are recommended for the transfer of the position of the multi-implants.

  16. Preparation, thermal property and morphology analysis of waterborne polyurethane-acrylate

    NASA Astrophysics Data System (ADS)

    Zhao, Zhenyu; Jing, Zefeng; Qiu, Fengxian; Dai, Yuting; Xu, Jicheng; Yu, Zongping; Yang, Pengfei

    2017-01-01

    A series of waterborne polyurethane-acrylate (WPUA) dispersions were prepared with isophorone diisocyanate (IPDI), polyether polyol (NJ-210), dimethylol propionic acid (DMPA), hydroxyethyl methyl acrylate (HEMA), different proportions of methyl methacrylate (MMA) and ethyl acrylate (MMA and EA) and initiating agent by the emulsion co-polymerization. The structures, thermal properties and morphology of WPUA films were characterized with FT-IR, DSC, SEM and AFM. Performances of the dispersions and films were studied by means of apparent viscidity, particle size and polydispersity, surface tension and mechanical properties. The obtained WPUA have great potential application such as coatings, leather finishing, adhesives, sealants, plastic coatings and wood finishes.

  17. Effect of light-curing, pressure, oxygen inhibition, and heat on shear bond strength between bis-acryl provisional restoration and bis-acryl repair materials.

    PubMed

    Shim, Ji-Suk; Lee, Jeong-Yol; Choi, Yeon-Jo; Shin, Sang-Wan; Ryu, Jae-Jun

    2015-02-01

    This study aimed to discover a way to increase the bond strength between bis-acryl resins, using a comparison of the shear bond strengths attained from bis-acryl resins treated with light curing, pressure, oxygen inhibition, and heat. Self-cured bis-acryl resin was used as both a base material and as a repair material. Seventy specimens were distributed into seven groups according to treatment methods: pressure - stored in a pressure cooker at 0.2 Mpa; oxygen inhibition- applied an oxygen inhibitor around the repaired material,; heat treatment - performed heat treatment in a dry oven at 60℃, 100℃, or 140℃. The shear bond strength was measured with a universal testing machine, and the shear bond strength (MPa) was calculated from the peak load of failure. A comparison of the bond strength between the repaired specimens was conducted using one-way ANOVA and Tukey multiple comparison tests (α=.05). There were no statistically significant differences in the shear bond strength between the control group and the light curing, pressure, and oxygen inhibition groups. However, the heat treatment groups showed statistically higher bond strengths than the groups treated without heat, and the groups treated at a higher temperature resulted in higher bond strengths. Statistically significant differences were seen between groups after different degrees of heat treatment, except in groups heated at 100℃ and 140℃. Strong bonding can be achieved between a bis-acryl base and bis-acryl repair material after heat treatment.

  18. On the Edge: Haptic Discrimination of Edge Sharpness

    PubMed Central

    Skinner, Andy L.; Kent, Christopher; Rossiter, Jonathan M.; Benton, Christopher P.; Groen, Martin G. M.; Noyes, Jan M.

    2013-01-01

    The increasing ubiquity of haptic displays (e.g., smart phones and tablets) necessitates a better understanding of the perceptual capabilities of the human haptic system. Haptic displays will soon be capable of locally deforming to create simple 3D shapes. This study investigated the sensitivity of our haptic system to a fundamental component of shapes: edges. A novel set of eight high quality shape stimuli with test edges that varied in sharpness were fabricated in a 3D printer. In a two alternative, forced choice task, blindfolded participants were presented with two of these shapes side by side (one the reference, the other selected randomly from the remaining set of seven) and after actively exploring the test edge of each shape with the tip of their index finger, reported which shape had the sharper edge. We used a model selection approach to fit optimal psychometric functions to performance data, and from these obtained just noticeable differences and Weber fractions. In Experiment 1, participants performed the task with four different references. With sharpness defined as the angle at which one surface meets the horizontal plane, the four JNDs closely followed Weber’s Law, giving a Weber fraction of 0.11. Comparisons to previously reported Weber fractions from other haptic manipulations (e.g. amplitude of vibration) suggests we are sufficiently sensitive to changes in edge sharpness for this to be of potential utility in the design of future haptic displays. In Experiment 2, two groups of participants performed the task with a single reference but different exploration strategies; one was limited to a single touch, the other unconstrained and free to explore as they wished. As predicted, the JND in the free exploration condition was lower than that in the single touch condition, indicating exploration strategy affects sensitivity to edge sharpness. PMID:24023852

  19. Comparison of AcrySof MA30BA and Sensar AR40 acrylic intraocular lenses.

    PubMed

    Casprini, Fabrizio; Tosi, Gian Marco; Quercioli, Pier Paolo; Caporossi, Aldo

    2002-07-01

    To compare differences in anterior (ACO) and posterior (PCO) capsule opacification and subjective glare between 2 acrylic intraocular lenses (IOLs): AcrySof MA30BA (Alcon) and Sensar AR40 (Allergan). Department of Ophthalmology and Neurosurgery, University of Siena, Siena, Italy. This retrospective study comprised 100 cataract patients who had phacoemulsification and IOL implantation. Fifty eyes of 50 patients received an MA30BA and 50 eyes of 50 patients, an AR40. The mean postoperative follow-up was 25 months (range 20 to 31 months) and 22 months (range 19 to 29 months), respectively. Examiners subjectively evaluated ACO, and a photographic image-analysis system was used to assess PCO. All patients received a questionnaire to evaluate the incidence of subjective photic phenomena. In the MA30BA group, 60% had no ACO, 19% had mild ACO, and 21% had anterior capsule fibrosis. In the AR40 group, 55% had no ACO, 27% had mild ACO, and 18% had anterior capsule fibrosis. In the MA30BA group, the mean PCO score measured by image-analysis was 0.043 (range 0.000 to 0.084) at 1 year and 0.125 (range 0.000 to 0.197) at 2 years and in the AR40 group, 0.071 (range 0.000 to 0.157) and 0.230 (range 0.091 to 0.628), respectively. Although the ACO percentages and the PCO scores at 1 year were not statistically different between the 2 groups (P >.05), the MA30BA group had statistically less PCO at 2 years (P <.05). In the MA30BA group, 36 patients had trouble reading in a dim environment, 25 had difficulty driving at night, 25 were mildly bothered by the lights of other vehicles, and 17 saw halos when looking at the lights of other vehicles and 17, when looking at lights at night. In the AR40 group, 7 patients had trouble reading in a dim environment and 11 had difficulty driving at night. At 6 months, the AR40 group had a statistically significantly lower incidence of photic phenomena than the MA30BA group (P <.05). In the MA30BA group 1 year after surgery, 13 patients had trouble

  20. Edge-Aware BMA Filters.

    PubMed

    Guang Deng

    2016-01-01

    There has been continuous research in edge-aware filters which have found many applications in computer vision and image processing. In this paper, we propose a principled-approach for the development of edge-aware filters. The proposed approach is based on two well-established principles: 1) optimal parameter estimation and 2) Bayesian model averaging (BMA). Using this approach, we formulate the problem of filtering a pixel in a local pixel patch as an optimal estimation problem. Since a pixel belongs to multiple local patches, there are multiple estimates of the same pixel. We combine these estimates into a final estimate using BMA. We demonstrate the versatility of this approach by developing a family of BMA filters based on different settings of cost functions and log-likelihood and log-prior functions. We also present a new interpretation of the guided filter and develop a BMA guided filter which includes the guided filter as a special case. We show that BMA filters can produce similar smoothing results as those of the state-of-the-art edge-aware filters. Two BMA filters are computationally as efficient as the guided filter which is one of the fastest edge-aware filters. We also demonstrate that the BMA guided filter is better than the guided filter in preserving sharp edges. A new feature of the BMA guided filter is that the filtered image is similar to that produced by a clustering process.

  1. Flap-Edge Blowing Experiments

    NASA Technical Reports Server (NTRS)

    Gaeta, R. J.; Englar, R. J.; Ahuja, K. K.

    2003-01-01

    This Appendix documents the salient results from an effort to mitigate the so-called flap-edge noise generated at the split between a flap edge that is deployed and the undeployed flap. Utilizing a Coanda surface installed at the flap edge, steady blowing was used in an attempt to diminish the vortex strength resulting from the uneven lift distribution. The strength of this lifting vortex was augmented by steady blowing over the deployed flap. The test article for this study was the same 2D airfoil used in the steady blowing program reported earlier (also used in pulsed blowing tests, see Appendix G), however its trailing edge geometry was modified. An exact duplicate of the airfoil shape was made out of fiberglass with no flap, and in the clean configuration. It was attached to the existing airfoil to make an airfoil that has half of its flap deployed and half un-deployed. Figure 1 shows a schematic of the planform showing the two areas where steady blowing was introduced. The flap-edge blowing or the auxiliary blowing was in the direction normal to the freestream velocity vector. Slot heights for the blowing chambers were on the order of 0.0 14 inches.

  2. Internal view of the effects of the big-bubble technique during experimental deep anterior lamellar keratoplasty.

    PubMed

    Gatell, Jordi

    2012-12-01

    To determine how the air bubble dissects Descemet membrane from the inside during experimental deep lamellar anterior keratoplasty. In this experimental study, 4 corneas from enucleated human eyes were dissected and placed in an artificial anterior chamber. Air was injected through a 27-gauge needle into the midperiphery without previous trephination until a big bubble formed. The results were photographed from the inside. The edge of the air dissection was viewed clearly. The dissection was not uniform; one side was dissected more than the other. Descemet membrane and the stroma may still have been attached. The results provided a clue about why perforation frequently occurs when dissecting the anterior lamella in the periphery. As much air as possible should be injected. Premature cessation of the injection of air can result in irregular dissection by all edges of the bubble or an incomplete bubble.

  3. Impact of interventional edge-to-edge repair on mitral valve geometry.

    PubMed

    Schueler, Robert; Kaplan, Sarah; Melzer, Charlotte; Öztürk, Can; Weber, Marcel; Sinning, Jan-Malte; Welz, Armin; Werner, Nikos; Nickenig, Georg; Hammerstingl, Christoph

    2017-03-01

    The acute and long-term effects of interventional edge-to-edge repair on the mitral valve (MV) geometry are unclear. We sought to assess MV-annular geometry and the association of changes in MV-diameters with functional response one year after MitraClip implantation. Consecutive patients (n=84; age 81.2±8.3years, logistic EuroSCORE 21.7±17.9%) with symptomatic moderate-to-severe mitral regurgitation (MR) underwent MitraClip-procedure. MV-annular geometry was assessed with 3D TOE before, immediately and one year after clip implantation. 96.7% of secondary mitral regurgitation (SMR) patients presented with moderate-to-severe MR, 3.3% with severe SMR, respectively. 66.7% of primary MR (PMR) patients had moderate-to-severe MR, and 33.3% severe PMR respectively. When analyzing immediate effects of MitraClipC on mitral geometry, only patients with SMR (n=60, 71.4%) experienced significant reductions of the diastolic MV anterior-posterior diameters (AP: 3.9±0.5cm, 3.5±0.7cm; p<0.001), and annulus-areas (2D: 12.9±3.8cm2, 12.6±3.7cm2; p<0.001; 3D: 13.4±3.8, 13.1±3.2cm2; p<0.001). All measures on MV annular geometry were not significantly altered in patients with PMR (p>0.05). After one year of follow-up, MV annular parameters remained significantly reduced in SMR patients (p<0.05) and remained unchanged in subjects with PMR (p>0.05). Only SMR patients experienced significant increase in 6min walking distances (p=0.004), decrease in pulmonary pressures (p=0.007) and functional NYHA-class (p<0.001); in patients with PMR only NYHA class improved after one year (p<0.001). Edge-to-edge repair with the MitraClip-system impacts on MV-geometry in patients with SMR with stable results after 12months. Reduction of MV-annular dimensions was associated with higher rates of persisting MR reduction and better functional status in patients with SMR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.

    PubMed

    Khokhar, Sudarshan Kumar; Midha, Neha; Patil, Bharat; Nayak, Bhagabat; Simakurthy, Sriram

    2016-01-01

    To describe a novel technique to release sticking haptic of a single-piece hydrophobic acrylic intraocular lens (IOL) using irrigation-aspiration (I/A) probe. In our technique, the I/A probe is introduced into the anterior chamber on Visco mode. Using the aspiration port of the I/A probe, the sticking haptic is held at its tip and suction force is built up until occlusion is noted. Then the haptic is nudged towards the center of the IOL along its curve. After the haptic is free from optic, the suction is released. Several techniques have been described to release the sticking haptic such as squeezing the haptic at the site where it sticks to the IOL or using Sinskey hook for releasing the adhesion. These techniques require extra manipulation of the IOL by introduction of surgical instruments. In our technique, we used the I/A probe itself for separating the sticky haptic successfully. This technique allows separation of sticking haptic without any extra instrumentation, thus reducing intraocular maneuvering and total surgery time.

  5. Biobased composites from thermoplastic polyurethane elastomer and cross-linked acrylated-epoxidized soybean oil

    USDA-ARS?s Scientific Manuscript database

    Soybean oil is an important sustainable material. Crosslinked acrylated epoxidized soybean oil (AESO) is brittle without flexibility and the incorporation of thermoplastic polyurethane improves its toughness for industrial applications. The hydrophilic functional groups from both oil and polyurethan...

  6. Preparation and characterization of emulsifier-free polyphenylsilsesquioxane-poly (styrene-butyl acrylate) hybrid particles

    NASA Astrophysics Data System (ADS)

    Bai, Ruiqin; Qiu, Teng; Han, Feng; He, Lifan; Li, Xiaoyu

    2013-10-01

    The core-shell polyphenylsilsesquioxane-poly (styrene-butyl acrylate) hybrid latex paticles with polyphenylsilsesquioxane as core and poly (styrene-butyl acrylate) as shell were successfully synthesized by seeded emulsion polymerization using polyphenylsisesquioxane (PPSQ) latex particles as seeds. X-ray diffraction (XRD) indicated that the polyphenylsilsesquioxane (PPSQ) had ladder structure, and PPSQ had incorporated into the hybrid latex particles. Transmission electron microscopy (TEM) confirmed that the resultant hybrid latex particles had the core-shell structure. TEM and dynamic light scattering (DLS) analysis indicated that the polyphenylsisesquioxane latex particles and obtained core-shell hybrid latex particles were uniform and possessed narrow size distributions. X-ray photoelectron spectroscopy (XPS) analysis also indicated that the PPSQ core particles were enwrapped by the polymer shell. In addition, compared with pure poly (styrene-butyl acrylate) latex film, the polyphenylsilsesquioxane-poly (styrene-butyl acrylate) hybrid latex film exhibited lower water uptake, higher pencil hardness and better thermal stability.

  7. Glycine derived polymerizable cosurfactant in the synthesis of functionalized poly(butyl acrylate) nanolatexes.

    PubMed

    Gaspar, L J Milton; Baskar, Geetha

    2006-04-01

    The approach of employing N-glycinylmaleamic acid (NGMA) as an efficient cosurfactant to provide microemulsion polymerization of butyl acrylate using a weight ratio of sodium dodecyl sulfate (SDS)/butyl acrylate (BA) at acrylate) copolymers from investigated microemulsion polymerization reactions evidences the promotion of a controlled polymerization reaction, in contrast to the solution polymerization method generating polymers with higher polydispersity index at 3.15-4.23. The enhanced incorporation of NGMA at approximately 0.35 m in the copolymer demonstrates the merits of the proximity effect enabled in the microemulsion polymerization reaction. The incorporation of NGMA promotes rigidity of the polymer chain as suggested by a higher Tg of -16.8 degrees C for the copolymer in comparison to that of the poly(butyl acrylate) homopolymer.

  8. Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical Acrylic Vessel Inner Surface

    NASA Astrophysics Data System (ADS)

    Broerman, B.; Boulay, M. G.; Cai, B.; Cranshaw, D.; Dering, K.; Florian, S.; Gagnon, R.; Giampa, P.; Gilmour, C.; Hearns, C.; Kezwer, J.; Kuźniak, M.; Pollmann, T.; Ward, M.

    2017-04-01

    DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a target medium to perform a sensitive spin-independent dark matter search. Argon scintillates in the vacuum ultraviolet spectrum, which requires wavelength shifting to convert the VUV photons to visible so they can be transmitted through the acrylic light guides and detected by the surrounding photomultiplier tubes. The wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene was evaporatively deposited to the inner surface of the acrylic vessel under vacuum. Two evaporations were performed on the DEAP-3600 acrylic vessel with an estimated coating thickness of 3.00 ± 0.02 μm which is successfully wavelength shifting with liquid argon in the detector. Details on the wavelength shifter coating requirements, deposition source, testing, and final performance are presented.

  9. Emulsion polymerization of polystyrene-co-acrylic acid with Cu2O incorporation

    NASA Astrophysics Data System (ADS)

    Fahmiati, Sri; Harmami, Sri Budi; Meliana, Yenny; Haryono, Agus

    2017-01-01

    In this research, poly(styrene-co-acrylic acid-Cu) was prepared via emulsion polymerization.Cu contents were varied as 10%, 15% and 20% and mol ratio of styrene to acrylic acid as 1:1 and 2:1. Structure and surface of poly(styrene-co-acrylic acid-Cu) were characterized by FTIR (Fourier Transformed Infra Red), NMR (Nuclear Magnetic Resonance), and SEM/EDX (Scanning Electron Microcope/ Energy Dispersive X-Ray) spectroscopy. The NMR spectra showed that the polymer was formed, however FTIR spectra showed that there were still unreacted monomers. SEM-EDX confirmed that copper (Cu) was dispersed uniformly on poly(styrene-co-acrylic acid-Cu) matrix.

  10. Novel (meth)acrylate monomers for ultrarapid polymerization and enhanced polymer properties

    SciTech Connect

    Beckel, E. R.; Berchtold, K. A.; Nie, J.; Lu, H.; Stansbury, J. W.; Bowman, C. N.

    2002-01-01

    Ultraviolet light is known to be one of the most efficient methods to initiatc polymeric reactions in the presence of a photonitiator. Photopolymerizations are advantageous because the chemistry of the materials can be tailored to design liquid monomers for ultrarapid polymerization into a solid polymer material. One way to achieve rapid photopolymerizations is to utilize multifunctional (meth)acrylate monomers. which form highly crosslinked polymers; however, these monomers typically do not achieve complete functional group conversion. Recently, Decker et al. developed novel monovinyl acrylate monomers that display polyriicrization kinetics that rival those of multifunctional acrylate monomers. These novel acrylate monomers incorporate secondary functionalities and end groups such as carbonates, carbamates, cyclic carbonates and oxazolidone which promote the increased polymerization kinetics of these monomers. In addition to thc polynierization kinetics, these novel monovinyl monomers form crosslinked polymers, which are characterized by having high strength and high flexibility. Unfortunately, the exact mechanism or mechanisms responsible for the polymerization kinetics and crosslinking are not well understood.

  11. Optical properties of UV transmitting acrylics for use in a heavy water Cerenkov detector

    SciTech Connect

    Zwinkels, J.C.; Davidson, W.F.; Dodd, C. )

    1990-08-01

    The absorption, refraction, and scattering properties of several UV transmitting acrylics have been investigated over the wavelength range 300--700 nm using a combination of near-normal incidence regular transmittance and reflectance and diffuse-only reflectance measurements, followed by a Fresnel and a Kubelka-Munk analysis. The samples were evaluated in the as-cast and thermoformed forms, and both before and after an accelerated aging procedure. The results show significant differences in the optical behavior of the various acrylics in the UV region and stress the importance of carefully characterizing acrylic from different sources for each intended use. In our case, acrylic is the proposed material for a heavy water containment vessel for the detection of solar neutrinos. The significance of our findings to the overall performance of this Cerenkov detector, known as the Sudbury neutrino observatory detector, is discussed.

  12. Synergistic effect of additives including multifunctional acrylates in wood plastic composites

    NASA Astrophysics Data System (ADS)

    Khan, Mubarak A.; Idriss Ali, K. M.; Garnett, John L.

    1993-07-01

    Wood Plastic Composite (WPC) was prepared with simul (soft wood, density = 0.4g/cc) and butylmethacrylate (BMA) monomer using 10% methanol as the swelling agent. Effect of additives including (i) multifunctional acrylates such as tripropylene glycol diacrylate (TPGDA), trimethylol propane triacrylate (TMPTA) (ii) oligomer acrylates like the urethane (UA), epoxy (EA) and polyester (PEA) acrylates and (iii) N-vinyl pyrrolidone (NVP) was investigated using 1 to 3 Mrad dose at 0.8 Mrad/h. Synergistic increases in polymer loading yields was achieved in presence of the additives, particularly with the trifunctional acrylate (TMPTA). In addition, acid as well as urea were also used as co-additives and synergistic enhancement in yields of polymer loading were obtained. The synergistic polymer loading by acid addition causes substantial decrease in tensile strength of the composite; but other additives and co-additives increase both the polymer loading and the tensile strength in these systems.

  13. Synthesis of acrylates. Quarterly progress report, April 1, 1995--June 30, 1995

    SciTech Connect

    1995-09-05

    The objective of this research is to develop a condensation/oxidation route for the synthesis of acrylates/methacrylates from coal-derived synthesis gas. This quarter work continued on the development of catalysts for propionate synthesis.

  14. Removal of methyl acrylate by ceramic-packed biotrickling filter and their response to bacterial community.

    PubMed

    Wu, Hao; Yin, Zhenhao; Quan, Yue; Fang, Yingyu; Yin, Chengri

    2016-06-01

    Methyl acrylate is a widely used raw chemical materials and it is toxic in humans. In order to treat the methyl acrylate waste gas, a 3-layer BTF packed with ceramic particles and immobilized with activated sludge was set up. The BTF exhibited excellent removal efficiency that no methyl acrylate could be detected when EBRT was larger than 266s and inlet concentration was lower than 0.19g/m(3). The 1st layer performed the best at fixed inlet concentration of 0.42g/m(3). PCR combined with DGGE was performed to detect the differences in different layers of the BTF. Phylum Proteobacteria (e.g. α-, β-, γ-, δ-) was predominantly represented in the bacterial community, followed by Actinobacteria and Firmicutes. Desulfovibrio gigas, Variovorax paradoxus, Dokdonella koreensis, Pseudoxanthomonas suwonensis, Azorhizobium caulinodans, Hyphomicrobium denitrificans, Hyphomicrobium sp. and Comamonas testosteroni formed the bacteria community to treat methyl acrylate waste gas in the BTF.

  15. [Resistance and deformation of acrylic resin reinforced with cut and ground fiberglass. 2. Rupture lengthening].

    PubMed

    Fregonesi, L A; Campos, G M; Panzeri, H

    1990-01-01

    The rupture lengthening test demonstrated the addition of fiberglass to acrylic resin tends to make the test bodies more rigid, making them fracture with a shorter lengthening than unloaded resin. The greatest rigidity was observed with a 20% load.

  16. Methyl (E)-2-[(2-nitro-phen-oxy)meth-yl]-3-phenyl-acrylate.

    PubMed

    Anuradha, T; Devaraj, A; Seshadri, P R; Bakthadoss, M

    2012-06-01

    The title compound, C(17)H(15)NO(5), adopts an E conformation with respect to the C=C double bond of the phenyl-acrylate unit. The phenyl ring and methyl acrylate group of the phenyl-acrylate unit are disordered over two sets of sites with site-occupancy ratios of 0.705 (5):0.295 (5) and 0.683 (3):0.317 (3), respectively. The mean plane through the benzene ring of the phenyl acrylate makes dihedral angles of 88.4 (8) (major component) and 86.7 (8)° (minor component) with the nitro-phen-oxy ring; the dihedral angle between the two components is 3.64 (6)°. Intra-molecular C-H⋯O interactions stabilise the molecular structure. In the crystal, C-H⋯O inter-actions result in a chain of mol-ecules running along the b axis.

  17. Reductive functionalization of carbon dioxide to methyl acrylate at zerovalent tungsten.

    PubMed

    Wolfe, Justin M; Bernskoetter, Wesley H

    2012-09-21

    Alkali metal reduction of tungsten tetrachloride in the presence of excess trimethylphosphite and ethylene affords moderate yields of trans-tetrakis(trimethylphosphite)tungsten bis(ethylene). This easily prepared species bearing inexpensive ancillary ligands promotes the oxidative coupling of carbon dioxide and ethylene at ambient temperature to produce two isomeric tetrakis(trimethylphosphite)tungsten acrylate hydride complexes. These isomers vary by the κ(2)-O,O and κ(3)-C,C,O coordination mode of the acrylate ligand, and swiftly interconvert in solution as detected by 2D NMR spectroscopy. The CO(2)-derived acrylate fragment may be released from the tungsten coordination sphere by treatment with methyl iodide to afford modest quantities of free methyl acrylate.

  18. Anterior crowns in re-establishing vertical dimension of occlusion: overcoming fear of heights.

    PubMed

    Blitz, N

    1997-02-01

    The rejuvenation of this dentition is initiated with the placement of six anterior crowns. Re-establishing the vertical dimension has allowed the restoration of pleasing proportions to the centrals. This has led to the re-assertion of the dominance of the centrals and thus corrected the reverse smile line. The restoration of these teeth demands harmonious accommodation of the requirements of esthetics, phonetics and function. These considerations are inseparable and are in fact, determinants of each other. Esthetics and phonetics help determine the degree of vertical opening and incisal edge placement. This location influences anterior guidance, lingual and labial contours, the pitch of the anterior teeth and proper lip support. The principles of proportion, so important in esthetics, allow us, to calculate incisor length. Thus, function, phonetics and esthetics are intimately intertwined and enhance one another in the restoration of vertical dimension of occlusion.

  19. Distal anterior cerebral artery aneurysms.

    PubMed

    Lehecka, Martin; Dashti, Reza; Lehto, Hanna; Kivisaari, Riku; Niemelä, Mika; Hernesniemi, Juha

    2010-01-01

    Distal anterior cerebral artery (DACA) aneurysms, also known as pericallosal artery aneurysms, represent about 6% of all intracranial aneurysms. They are located on the A2-A5 segments of the anterior cerebral artery and on its distal branches. This paper summarizes present knowledge on radiological features, treatment options, treatment results, and long-term follow-up of DACA aneurysms. Typical features of DACA aneurysms are small size, broad base, and branches originating from the base. When ruptured, they cause intracerebral hematoma in nearly half of the cases. DACA aneurysms are nowadays more often treated with microsurgical clipping than endovascular coiling due to their distal location and morphologic features. With clipping the results are same or slightly better than for aneurysms at other locations, coiling is often associated with more complications than in other aneurysms. Clipping is a long-lasting treatment with very small recurrence rate, there is no long-term data available on efficacy of coiling yet. For ruptured DACA aneurysms the most important factors affecting outcome is the severity of initial bleeding and patient's age.

  20. [Anterior skull-base schwannoma].

    PubMed

    Esquivel-Miranda, Miguel; De la O Ríos, Elier; Vargas-Valenciano, Emmanuelle; Moreno-Medina, Eva

    2017-06-24

    Schwannomas are nerve sheath tumours that originate in Schwann cells. They are usually solitary and sporadic and manifest on peripheral, spinal or cranial nerves. Intracranial schwannomas tend to manifest on the eighth cranial nerve, particularly in patients with neurofibromatosis type2. Anterior skull-base schwannomas represent less than 1% of all intracranial schwannomas. They are more frequent in young people and are typically benign. These tumours represent a diagnostic challenge due to their rarity and difficult differential diagnosis, and numerous theories have been postulated concerning their origin and development. In this article, we present the case of a 13-year-old male with a single anterior cranial-base tumour not associated with neurofibromatosis who presented with headache, papilloedema, eye pain and loss of visual acuity. Complete resection of the tumour was performed, which was histopathologically diagnosed as a schwannoma. The patient made a complete clinical recovery with abatement of all symptoms. We conducted a review of the literature and found 66 cases worldwide with this diagnosis. We describe the most relevant epidemiological and clinical characteristics of this kind of tumour and its relation with the recently discovered and similar olfactory schwannoma. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

    PubMed Central

    Jang, Dae-Eun; Lee, Ji-Young; Jang, Hyun-Seon; Lee, Jang-Jae

    2015-01-01

    PURPOSE The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed. PMID:26330974

  2. Fast-Curing Epoxy and Acrylate Adhesive Development for Adverse Marine Conditions

    DTIC Science & Technology

    2013-07-01

    were the same as above except they were painted with gloss black enamel paint and allowed to dry 24 h prior to application of any adhesives ...Fast-Curing Epoxy and Acrylate Adhesive Development for Adverse Marine Conditions by Daniel M. De Bonis, Steven Klankowski, Daniel Stewart...Aberdeen Proving Ground, MD 21005-5069 ARL-TR-6521 July 2013 Fast-Curing Epoxy and Acrylate Adhesive Development for Adverse Marine

  3. Catalytic Cracking of Lactide and Poly(Lactic Acid) to Acrylic Acid at Low Temperatures

    PubMed Central

    Terrade, Frédéric G.; van Krieken, Jan; Verkuijl, Bastiaan J. V.

    2017-01-01

    Abstract Despite being a simple dehydration reaction, the industrially relevant conversion of lactic acid to acrylic acid is particularly challenging. For the first time, the catalytic cracking of lactide and poly(lactic acid) to acrylic acid under mild conditions is reported with up to 58 % yield. This transformation is catalyzed by strong acids in the presence of bromide or chloride salts and proceeds through simple SN2 and elimination reactions. PMID:28375546

  4. In vitro cytotoxicity of self-curing acrylic resins of different colors.

    PubMed

    Retamoso, Luciana Borges; da Cunha, Taís de Morais Alves; Pithon, Matheus Melo; dos Santos, Rogério Lacerda; Martins, Fernanda Otaviano; Romanos, Maria Teresa Villela; Tanaka, Orlando Motohiro

    2014-01-01

    The aim of this study was to assess the in vitro cytotoxicity of acrylic resins of different colors over time. Specimens were divided into 4 groups (n = 6) according to the color of the acrylic resin (Orto Class, Clássico, Campinas, São Paulo, Brazil): Group 1, clear acrylic resin; Group 2, pink acrylic resin; Group 3, blue acrylic resin; and Group 4, green acrylic resin. All specimens were fabricated according to the mass manipulation technique and submitted to mechanical polishing protocol. The control was performed with an amalgam specimen (C+), a glass specimen (C-) and cell control (CC). Specimens were immersed in Minimum Eagle's Medium (MEM) and incubated for 24 h at 37ºC. The extracts from the experimental material were filtered and mixed with L929 fibroblast. Cytotoxicity was evaluated at four different times, 24, 48, 72 and 168 h. After contact, cells were incubated for 24 h and added to 100 µ of 0.01% neutral red dye. The cells were incubated for 3 h for pigment incorporation and fixed. Cells viability was determined by a spectroscopic (BioTek, Winooski, Vermont, USA) with a 492-nm wavelength λ=492 nm). There were no statistical differences between the experimental groups and the CC and C- groups. Clear, pink, blue and green self-curing acrylic resins fabricated by means of the mass manipulation technique and mechanically polished are not cytotoxic. Neither the pigment added to the self-curing acrylic resin nor the factor of time influenced the cytotoxicity of the material.

  5. In vitro cytotoxicity of self-curing acrylic resins of different colors

    PubMed Central

    Retamoso, Luciana Borges; da Cunha, Taís de Morais Alves; Pithon, Matheus Melo; dos Santos, Rogério Lacerda; Martins, Fernanda Otaviano; Romanos, Maria Teresa Villela; Tanaka, Orlando Motohiro

    2014-01-01

    Objective The aim of this study was to assess the in vitro cytotoxicity of acrylic resins of different colors over time. Methods Specimens were divided into 4 groups (n = 6) according to the color of the acrylic resin (Orto Class, Clássico, Campinas, São Paulo, Brazil): Group 1: clear acrylic resin; group 2: pink acrylic resin; group 3: blue acrylic resin and group 4: green acrylic resin. All specimens were fabricated according to the mass manipulation technique and submitted to mechanical polishing protocol. The control was performed with an amalgam specimen (C+), a glass specimen (C-) and cell control (CC). Specimens were immersed in Minimum Eagle's Medium (MEM) and incubated for 24 h at 37ºC. The extracts from the experimental material were filtered and mixed with L929 fibroblast. Cytotoxicity was evaluated at 4 different times, 24, 48, 72 and 168 h. After contact, cells were incubated for 24 h and added to 100 µ of 0.01% neutral red dye. The cells were incubated for 3 h for pigment incorporation and fixed. Cells viability was determined by a spectroscopic (BioTek, Winooski, Vermont, USA) with a 492-nm wavelength λ=492 nm). Results There were no statistical differences between the experimental groups and the CC and C- groups. Conclusion Clear, pink, blue and green self-curing acrylic resins fabricated by means of the mass manipulation technique and mechanically polished are not cytotoxic. Neither the pigment added to the self-curing acrylic resin nor the factor of time influenced the cytotoxicity of the material. PMID:25279523

  6. Investigation of a Relationship between Uniaxial and Biaxial Chemical Stress Crazing of Cast Acrylic

    DTIC Science & Technology

    1992-01-01

    number) FIELD GROUP SUB-GROUP Craze Initiation Chemical Craze Testing Uniaxial Stress Cast Acrylic Biaxial Stress Isopropyl Alcohol 19. ABSTRACT...cast acrylic with isopropyl alcohol . ASTM Standard Test Methods F484 and F1164 were used as guidelines for the uniaxial craze testing and biaxial...uniaxial and biaxial craze tests was conducted at various stress levels in conjunction with isopropyl alcohol . Isopropyl alcohol was the chosen chemical

  7. Effect of intrinsic nanoparticle pigmentation on the color stability of denture base acrylic resins.

    PubMed

    Goiato, Marcelo Coelho; Zuccolotti, Bruna Carolina Rossatti; dos Santos, Daniela Micheline; Sinhoreti, Mário Alexandre Coelho; Moreno, Amália

    2013-08-01

    Intrinsic pigmentation is widely used to improve the esthetic features of denture base acrylic resins. However, acrylic resin may discolor over time. The purpose of this study was to investigate the effect of intrinsic nanoparticle pigmentation on the color stability of acrylic resins. The acrylic resins, Onda Cryl, QC 20, Classico, and Lucitone, were evaluated. Twenty-one disk-shaped specimens (3 × 30 mm) were fabricated from each acrylic resin. Seven were colored with 3% Poli-Cor intrinsic pigment used to color denture base, 7 were colored with 7% pigment, and 7 were not pigmented. In addition, 7 specimens were fabricated containing only pigment. The specimens were thermally cycled 2000 times between 5°C and 55°C with a 30-second dwell time at each temperature. The specimen colors were measured with a spectrophotometer and evaluated with the CIE L*a*b* system before (B) and after thermal cycling (T). The pigment morphology was analyzed by using a scanning electron microscope (SEM) and energy-dispersive x-ray spectroscopy (EDS) techniques. The results were analyzed with 2-way nested ANOVA and Tukey HSD tests (α=.05). Classico acrylic resin with and without pigment underwent the least color change, followed in order by Lucitone, Onda Cryl, and QC-20. The presence of pigments reduced the color change of the acrylic resins significantly (P<.05) for the specimens containing 7% pigment (0.32 ±0.18 ΔE). Titanium was the sole metallic component present in the pigment, probably in the oxide form (TiO2). Nanoparticle pigments enhanced the color stability of denture base acrylic resins.

  8. Testing of gloves for permeability to UV-curable acrylate coatings

    SciTech Connect

    Huggins, R.; Levy, N.; Pruitt, P.M.

    1987-07-01

    The handling of UV-curable acrylate formulations used in the coating of optical fiber requires protective measures to prevent contact dermatitis and/or allergic dermatitis. To characterize the permeability of various glove materials to a UV-curable acrylate coating, a study was undertaken using a modification of a standard ASTM permeability test, which demonstrated that nitrile rubber gloves provided the best protection of those glove materials tested.

  9. [Resistance and deformation of acrylic resin reinforced with cut and ground fiberglass. 1. Rupture tension].

    PubMed

    Fregonesi, L A; Campos, G M; Panzeri, H

    1990-01-01

    Traction trials were carried out on acrylic resin test bodies for denture frames reinforced with cut and ground fiberglass, to determine rupture tension. The results demonstrated that: 1--Cut fibers tend to increase the resistance of acrylic to traction forces, and the increase in load percentage of these fibers also increase resistance. 2--This increase was more marked when treatment with SILANE A 174 was combined with the use of cut fibers, at all concentrations tested.

  10. Supporting interactive graph exploration using edge plucking

    NASA Astrophysics Data System (ADS)

    Wong, Nelson; Carpendale, Sheelagh

    2007-01-01

    Excessive edge density in graphs can cause serious readability issues, which in turn can make the graphs difficult to understand or even misleading. Recently, we introduced the idea of providing tools that offer interactive edge bending as a method by which edge congestion can be disambiguated. We extend this direction, presenting a new tool, Edge Plucking, which offers new interactive methods to clarify node-edge relationships. Edge Plucking expands the number of situations in which interactive graph exploration tools can be used to address edge congestion.

  11. Role of Edges in Complex Network Epidemiology

    NASA Astrophysics Data System (ADS)

    Zhang, Hao; Jiang, Zhi-Hong; Wang, Hui; Xie, Fei; Chen, Chao

    2012-09-01

    In complex network epidemiology, diseases spread along contacting edges between individuals and different edges may play different roles in epidemic outbreaks. Quantifying the efficiency of edges is an important step towards arresting epidemics. In this paper, we study the efficiency of edges in general susceptible-infected-recovered models, and introduce the transmission capability to measure the efficiency of edges. Results show that deleting edges with the highest transmission capability will greatly decrease epidemics on scale-free networks. Basing on the message passing approach, we get exact mathematical solution on configuration model networks with edge deletion in the large size limit.

  12. Edge enhanced morphology for infrared image analysis

    NASA Astrophysics Data System (ADS)

    Bai, Xiangzhi; Liu, Haonan

    2017-01-01

    Edge information is one of the critical information for infrared images. Morphological operators have been widely used for infrared image analysis. However, the edge information in infrared image is weak and the morphological operators could not well utilize the edge information of infrared images. To strengthen the edge information in morphological operators, the edge enhanced morphology is proposed in this paper. Firstly, the edge enhanced dilation and erosion operators are given and analyzed. Secondly, the pseudo operators which are derived from the edge enhanced dilation and erosion operators are defined. Finally, the applications for infrared image analysis are shown to verify the effectiveness of the proposed edge enhanced morphological operators. The proposed edge enhanced morphological operators are useful for the applications related to edge features, which could be extended to wide area of applications.

  13. Continuous process of preparation of n-butyl(meth)acrylate by esterification of (meth)acrylic acid by butanol on thermostable sulfo-cation exchanger

    SciTech Connect

    Zheleznaya, L.L.; Karakhanov, R.A.; Lunin, A.F.; Magadov, R.S.; Meshcheryakov, S.V.; Mkrtychan, V.R.; Fomin, V.A.

    1987-11-10

    The authors propose an effective thermostable sulfo-cation exchanger based on polymers with a system of conjugated bonds, sulfopolyphenylene ketone (SPP) differing from the known cation exchangers by the high thermostability (up to 250/sup 0/C), and also having the effect of the stabilization of the double bond in unsaturated monomers. The combination of inhibiting and cation exchange properties makes it also possible to use these sulfo-cation exchangers in the processes of esterification of (meth)acrylic acids by alcohols without addition of special inhibitors. The SPP catalyst was tested in esterification processes of acrylic an methacrylic acid by butanol at a pilot plant.

  14. Allergic contact dermatitis from sculptured acrylic nails: special presentation with an airborne pattern.

    PubMed

    Maio, Paula; Carvalho, Rodrigo; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge

    2012-01-02

    Methylmethacrylate was first reported in 1941 as a cause of contact dermatitis. Since then, occupational contact allergies to acrylates in dentistry, orthopedic surgery, printing industry and industry have been reported, but few reports are found in the literature as a consequence of the contact with sculptured artificial acrylic nails which are increasingly popular. We describe here 3 patients with contact allergy to acrylates in artificial sculptured nails. Patch tests were performed with the Portuguese baseline series of contact allergens and an extended series of acrylates were applied. In particular, we tested three female patients with allergic contact dermatitis from sculptured acrylic nails. Two of these patients were both customers and also technical nail beauticians. Two patients developed periungual eczema; one presented only with face and eyelid dermatitis had no other lesions. The tests showed positive reaction to 2-hydroxyethylmethacrylate (2-HEMA) and 2-hydroxypropylmethacrylate (2-HPMA) in all the three patients. Our cases demonstrate the variety of clinical presentations of allergic contact dermatitis from acrylic sculptured nails. They show the need to warn patients of persistent and sometimes permanent side effects of these products. They also emphasize the importance of cosmetic ingredient labeling.

  15. Letter: Allergic contact dermatitis from sculptured acrylic nails: special presentation with a possible airborne pattern.

    PubMed

    Maio, Paula; Carvalho, Rodrigo; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge

    2012-02-15

    Sculptured artificial acrylic nails are widely used in developed countries. Methylmethacrylate was first reported in 1941 as a cause of allergic contact dermatitis. Since then, occupational contact allergies to acrylates in dentistry, orthopedic surgery, printing industry and other industries have been reported. We describe 3 patients with contact allergy to acrylates in artificial nails. Patch tests with the Portuguese baseline series of contact allergens and an extended series of acrylates was applied. We observed three female patients with allergic contact dermatitis from sculptured acrylic nails. Two of these patients were both customers and also technical nail beauticians. Two patients developed periungual eczema; one patient presented only with eyelid dermatitis and no hand or periungual lesions. The tests showed positive reactions to 2-hydroxyethylmethacrylate (2-HEMA) and 2-hydroxypropylmethacrylate (2-HPMA) in three patients. Our cases demonstrate the variety of clinical presentations of allergic contact dermatitis from acrylic nails. They show the need to warn patients of persistent and sometimes permanent side effects of these nails. They also emphasize the importance of cosmetic ingredient labeling.

  16. Radiation-induced grafting of acrylic acid onto polypropylene film and its biodegradability

    NASA Astrophysics Data System (ADS)

    Mandal, Dev K.; Bhunia, Haripada; Bajpai, Pramod K.; Chaudhari, C. V.; Dubey, K. A.; Varshney, L.

    2016-06-01

    Polypropylene based commodity polyolefins are widely used in packaging, manufacturing, electrical, pharmaceutical and other applications. The aim of the present work is to study the effect of grafting of acrylic acid on the biodegradability of acrylic acid grafted polypropylene. The effect of different conditions showed that grafting percentage increased with increase in monomer concentration, radiation dose and inhibitor concentration but decreased with increase in radiation dose rate. The maximum grafting of 159.4% could be achieved at optimum conditions. The structure of grafted polypropylene films at different degree of grafting was characterized by EDS, FTIR, TGA, DSC, SEM and XRD. EDS studies showed that the increase in acrylic acid grafting percentage increased the hydrophilicity of the grafted films. FTIR studies indicated the presence of acrylic acid on the surface of polypropylene film. TGA studies revealed that thermal stability decreased with increase in grafting percentage. DSC studies showed that melting temperature and crystallinity of the grafted polypropylene films lower than polypropylene film. SEM studies indicated that increase in acrylic acid grafting percentage increased the wrinkles in the grafted films. The maximum biodegradability could be achieved to 6.85% for 90.5% grafting. This suggested that microorganisms present in the compost could biodegrade acrylic acid grafted polypropylene.

  17. Controlled radical fluorination of poly(meth)acrylic acids in aqueous solution.

    PubMed

    Dong, Yucheng; Wang, Zhentao; Li, Chaozhong

    2017-08-17

    Fluorinated alkenes exhibit very poor reactivity in copolymerization with non-fluorinated polar monomers such as acrylates. Herein we describe a convenient method for the synthesis of poly(vinyl fluoride-co-acrylic acid) and poly(2-fluoropropene-co-methacrylic acid) copolymers. Thus, the silver-catalyzed decarboxylative radical fluorination of poly(acrylic acid) with Selectfluor in water at room temperature affords poly(vinyl fluoride-co-acrylic acid) copolymers in high yields with well-defined molecular weights and polydispersities. A linear correlation is observed between the extent of fluorination and the amount of Selectfluor, indicating that the copolymer of virtually any monomer ratio can be readily accessed by controlling the amount of Selectfluor. This controlled decarboxylative fluorination is extended to poly(methacrylic acid), leading to well-defined poly(2-fluoropropene-co-methacrylic acid) copolymers.Fluorinated alkenes have very poor reactivity in copolymerizations with non-fluorinated polar monomers. Here the authors show silver-catalyzed decarboxylative radical fluorination of poly(acrylic acid) with Selectfluor in water at room temperature to form poly(vinyl fluoride-co-acrylic acid) copolymers.

  18. Effect of microwave treatments on dimensional accuracy of maxillary acrylic resin denture base.

    PubMed

    Pavan, Sabrina; Arioli Filho, João Neudenir; Dos Santos, Paulo Henrique; Mollo, Francisco de Assis

    2005-01-01

    Microwave energy has been used as an alternative method for disinfection and sterilization of dental prostheses. This study evaluated the influence of microwave treatment on dimensional accuracy along the posterior palatal border of maxillary acrylic resin denture bases processed by water-bath curing. Thirty maxillary acrylic bases (3-mm-thick) were made on cast models with Clássico acrylic resin using routine technique. After polymerization and cooling, the sets were deflasked and the bases were stored in water for 30 days. Thereafter, the specimens were assigned to 3 groups (n=10), as follows: group I (control) was not submitted to any disinfection cycle; group II was submitted to microwave disinfection for 3 min at 500 W; and in group III microwaving was done for 10 min at 604 W. The acrylic bases were fixed on their respective casts with instant adhesive (Super Bonder) and the base/cast sets were sectioned transversally in the posterior palatal zone. The existence of gaps between the casts and acrylic bases was assessed using a profile projector at 5 points. No statistically significant differences were observed between the control group and group II. However, group III differed statistically from the others (p<0.05). Treatment in microwave oven at 604 W for 10 min produced the greatest discrepancies in the adaptation of maxillary acrylic resin denture bases to the stone casts.

  19. Radiopurity measurement of acrylic for the DEAP-3600 dark matter experiment

    NASA Astrophysics Data System (ADS)

    Nantais, Corina Michelle

    2014-05-01

    The liquid argon target of the DEAP-3600 dark matter detector is contained by an extremely radiopure acrylic vessel. Alpha decays from the inner surface of the acrylic vessel are a source of background. If a fraction of the alpha energy is observed, or if the recoiling nucleus from the alpha decay is observed, the event will not be separated from a dark matter candidate event. In addition to the low level of inherent contamination from uranium and thorium, the Pb-210 from Rn-222 diffusion during manufacturing must be measured. The limit for the DEAP-3600 acrylic vessel is 1.1 x 10-20 g/g Pb-210. By vaporizing a large quantity of acrylic and counting the concentrated residue with an ultralow background HPGe well detector and a low background alpha spectrometer, the bulk acrylic was found to have an upper limit of 10 -19 g/g Pb-210. The design, installation, commissioning, operation, and analysis for various aspects of the acrylic assay are described.

  20. Ultrasonic degradation of poly(methyl methacrylate-co-alkyl acrylate) copolymers.

    PubMed

    Konaganti, Vinod Kumar; Madras, Giridhar

    2010-02-01

    The copolymers, poly(methyl methacrylate-co-methyl acrylate) (PMMAMA), poly(methyl methacrylate-co-ethyl acrylate) (PMMAEA) and poly(methyl methacrylate-co-butyl acrylate) (PMMABA), of different compositions were synthesized and characterized. The effect of alkyl acrylate content, alkyl group substituents and solvents on the ultrasonic degradation of these copolymers was studied. A model based on continuous distribution kinetics was used to study the kinetics of degradation. The rate coefficients were obtained by fitting the experimental data with the model. The linear dependence of the rate coefficients on the logarithm of the vapor pressure of the solvent indicated that vapor pressure is the crucial parameter that controls the degradation process. The rate of degradation increases with an increase in the alkyl acrylate content. At any particular copolymer composition, the rate of degradation follows the order: PMMAMA>PMMAEA>PMMABA. It was observed that the degradation rate coefficient varies linearly with the mole percentage of the alkyl acrylate in the copolymer.