2010-11-08
celiac aortic clamping (n=6), direct vascular control (n=6), and endovascular aortic occlusion n=6). This study presents a large animal model of class...including thoracic aortic clamping, supra- celiac aortic clamping, direct vascular control, and proximal endovascular balloon occlusion. Following vascular...subsequently underwent non-compressible hemorrhage with thoracic aortic clamping (n=6), supra- celiac aortic clamping (n=6), direct vascular control (n=6
Time to aortic occlusion: It's all about access.
Romagnoli, Anna; Teeter, William; Pasley, Jason; Hu, Peter; Hoehn, Melanie; Stein, Deborah; Scalea, Thomas; Brenner, Megan
2017-12-01
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less invasive method of proximal aortic occlusion compared with resuscitative thoracotomy with aortic cross-clamping (RTACC). This study compared time to aortic occlusion with REBOA and RTACC, both including and excluding time required for common femoral artery (CFA) cannulation. This was a retrospective, single-institution review of REBOA or RTACC performed between February 2013 and January 2016. Time of skin incision to aortic cross-clamp for RTACC, time required for CFA cannulation by percutaneous and open methods, and time from guide-wire insertion to balloon inflation at Zone 1 for REBOA, were obtained from videographic recordings. Eighteen RTACC and 21 REBOAs were performed. Median (Q1, Q3) time from skin incision to aortic cross-clamping was 317 seconds (227, 551 seconds). Median (Q1, Q3) time from start of arterial access to Zone 1 balloon occlusion was 474 seconds (431, 572 seconds) (vs. RTACC, p = 0.01). All REBOA procedures were performed with the same device. The median time to complete CFA cannulation was 247 seconds (range, 164-343 seconds), with no difference between percutaneous or open procedures (p = 0.07). The median (Q1, Q3) time to aortic occlusion in REBOA once arterial access had been established was 245 seconds (179, 295.5 seconds), which was significantly shorter than RTACC (p = 0.003). Once CFA access is achieved, time to aortic occlusion is faster with REBOA. Time to aortic occlusion is less than the time required to cannulate the CFA either by percutaneous or open approaches, emphasizing the importance of accurate and expedient CFA access. Resuscitative endovascular balloon occlusion of the aorta may represent a feasible alternative to thoracotomy for aortic occlusion. Time to aortic occlusion will likely decrease with the advent of newer REBOA technology. The rate-limiting portion of REBOA continues to be obtaining CFA access. Therapeutic, level V.
White, Joseph M; Cannon, Jeremy W; Stannard, Adam; Burkhardt, Gabriel E; Spencer, Jerry R; Williams, Ken; Oh, John S; Rasmussen, Todd E
2011-11-01
The optimal method of vascular control and resuscitation in patients with life-threatening, extrathoracic torso hemorrhage remains debated. Guidelines recommend emergency department thoracotomy (EDT) with aortic clamping, although transabdominal aortic clamping followed by vascular control and direct vascular control (DVC) without aortic clamping are alternatives. The objective of this study is to compare the effectiveness of three approaches to extrathoracic torso hemorrhage in a large animal model. Adolescent swine (Sus Scrofa) (mean weight = 80.9 kg) were randomized into three groups all of which had class IV shock established by hemorrhage from an iliac artery injury. Group 1: EDT with thoracic aortic clamping (N = 6); group 2: transabdominal supraceliac aortic clamping (SCC; N = 6); and group 3: DVC of bleeding site without aortic clamping (N = 6). After hemorrhage, EDT or SCC was performed in groups 1 and 2, respectively, with subsequent exploration of the bleeding site and placement of a temporary vascular shunt (TVS). Group 3 (DVC) underwent direct exploration of the injury and placement of a TVS. All groups were resuscitated to predefined physiologic endpoints over 6 hours with repeated measures of central and cerebral perfusion and end-organ function at standardized time points. Postmortem tissue analysis was performed to quantify injury to critical tissue beds. There was no difference in mortality among the groups and no TVS failures. Central aortic pressure, carotid flow, and partial pressure brain tissue oximetry, all demonstrated increases in EDT and SCC after application of the aortic clamp relative to DVC (p < 0.05). During resuscitation, serum lactate levels were higher in EDT compared with SCC and DVC (6.85 vs. 3.08 and 2.15, respectively; p < 0.05) and serum pH in EDT reflected greater acidosis than SCC and DVC (7.24 vs. 7.36 and 7.39, respectively; p < 0.05). EDT and SCC required more intravenous fluid than DVC (2,166 mL and 2,166 mL vs. 667 mL, respectively; p < 0.05) and more vasopressors were used in EDT and SCC compared with DVC (52.1 μg and 43.5 μg vs. 12.4 μg, respectively; p < 0.05). Brain and myocardial tissue stains demonstrated the same degree of acute ischemic changes in all groups. Although aortic clamping increases central and cerebral perfusion, DVC results in less physiologic derangement. The optimal method of aortic control would incorporate the benefits of maintained central pressure with less associated morbidity. Clinical studies evaluating DVC are warranted.
A Comparative Study of Different Hypothermic Circulatory Arrest Strategies on Aortic Surgery.
2018-03-22
Morality; Hypothermic Circulatory Arrest Time; Aortic-cross Clamping Time; Cardiopulmonary Bypass Time; Operation Time; Re-Thoracotomy; ICU Stay; Mechanical Ventilation Time; Blood Transfusion; Neurological Disorder; Dialysis; Aneurysm; Endoleak; Hospital Stay
Spinal cord protection in descending thoracic and thoracoabdominal aortic aneurysm repair.
Safi, H J; Campbell, M P; Ferreira, M L; Azizzadeh, A; Miller, C C
1998-01-01
During aneurysm repair of the descending thoracic or thoracoabdominal aorta, the likelihood of neurological complications increases greatly after only 30 minutes of spinal cord ischemia. However, the manifestation of paraplegia or paraparesis relates not only to aortic cross-clamping time, but to multiple factors that may include aortic dissection, previous aortic surgery, advanced age, preoperative renal insufficiency, rupture, and most significantly, aneurysm extent. At greatest risk is the patient with type II thoracoabdominal aortic aneurysm. For this patient the simple cross-clamp technique, which uses no protective surgical adjuncts, heightens the threat of neurological deficit. With the surgical adjuncts of cerebrospinal fluid drainage and distal aortic perfusion, the probability of neurological deficit is appreciably lowered.
Hurley, Eoghan T; O'Sullivan, Katie E; Segurado, Ricardo; Hurley, John P
2015-01-01
Sutureless aortic valve prostheses are anchored by radial force in a mechanism similar to that of transcatheter aortic valve implantation. Transcatheter aortic valve implantation is associated with an increased permanent pacemaker (PPM) requirement in a significant proportion of patients. We undertook a meta-analysis to examine the incidence of PPM insertion associated with sutureless compared with conventional surgical aortic valve replacement. A systematic review was conducted in accordance with the Prisma guidelines. All searches were performed on August 10, 2014. Studies between 2007 and 2014 were included in the search. A total of 832 patients were included in the sutureless group and 3,740 in the conventional group. Aortic cross-clamp (39.8 vs 62.4 minutes; P < 0.001) and cardiopulmonary bypass (64.9 vs 86.7 minutes; P = 0.002) times were shorter in the sutureless group. Permanent pacemaker implantation rate was higher in the sutureless cohort (9.1% vs 2.4%; P = 0.025). Sutureless aortic valve prostheses are associated with significantly shorter cardiopulmonary bypass and aortic cross-clamp times and a higher incidence of PPM insertion than conventional. Further investigation of the prognostic significance is required.
Arterial waves in humans during peripheral vascular surgery.
Khir, A W; Henein, M Y; Koh, T; Das, S K; Parker, K H; Gibson, D G
2001-12-01
The purpose of this study was to investigate the effect of aortic clamping on arterial waves during peripheral vascular surgery. We measured pressure and velocity simultaneously in the ascending aorta, in ten patients (70+/-5 years) with aortic-iliac disease intra-operatively. Pressure was measured using a catheter tip manometer, and velocity was measured using Doppler ultrasound. Data were collected before aortic clamping, during aortic clamping and after unclamping. Hydraulic work in the aortic root was calculated from the measured data, the reflected waves were determined by wave-intensity analysis and wave speed was determined by the PU-loop (pressure-velocity-loop) method; a new technique based on the 'water-hammer' equation. The wave speed is approx. 32% (P<0.05) higher during clamping than before clamping. Although the peak intensity of the reflected wave does not alter with clamping, it arrives 30 ms (P<0.05) earlier and its duration is 25% (P<0.05) longer than before clamping. During clamping, left ventricule (LV) hydraulic systolic work and the energy carried by the reflected wave increased by 27% (P<0.05) and 20% (P<0.05) respectively, compared with before clamping. The higher wave speed during clamping explains the earlier arrival of the reflected waves suggesting an increase in the afterload, since the LV has to overcome earlier reflected compression waves. The longer duration of the reflected wave during clamping is associated with an increase in the total energy carried by the wave, which causes an increase in hydraulic work. Increased hydraulic work during clamping may increase LV oxygen consumption, provoke myocardial ischaemia and hence contribute to the intra-operative impairment of LV function known in patients with peripheral vascular disease.
Cold cardioplegia versus hypothermia for myocardial protection. Randomized clinical study.
Conti, V R; Bertranou, E G; Blackstone, E H; Kirklin, J W; Digerness, S B
1978-11-01
Seventeen of 34 consecutive patients undergoing coronary artery bypass grafting were randomly assigned to one of two methods of myocardial preservation. With the cold cardioplegic method (Group A), a 4 degrees C. asanguineous solution with 30 mEq. of potassium per liter was infused into the aortic root for about 2 minutes immediately after aortic cross-clamping and again after about 45 minutes or when myocardial temperature rose above 19 degrees C. External cardiac cooling was provided by constant infusion of 4 degrees C. Ringer's solution into the pericardium. Seventeen patients were assigned to simple cardiac cooling by hypothermic systemic perfusion before aortic cross-clamping plus external cardiac cooling (Group B). Electromechanical activity ceased within 1 to 2 minutes in Group A but continued throughout the ischemic period in 14 patients in Group B. Myocardial temperature (mean for all observations) during aortic cross-clamping was 17.2 +/- 0.44 degrees C. In Group A and 24.0 +/- 0.70 degrees C. in Group B. Operating conditions were better in Group A. Card-ac function early postoperatively was good in both groups clinically and according to measurements, but only in the cold cardioplegic group (A) was cardiac index not adversely affected by longer cross-clamp time. Myocardial necrosis occurred in both groups but was probably less in the cold cardioplegic group. Thirteen patients (76 percent) in Group A had no electrocardiographic evidence of myocardial injury, compared with eight (47 percent) in Group B (p = 0.08). Eleven (65 percent of Group A had no or short-lived appearance of ceatine phosphokinase isoenzyme (CK-MB), compared with six (35 percent) of Group B (p = 0.08). Time-related CK-MB and SGOT mean levels were consistently lower in Group A.
Wu, YanWen; Xiao, LiQiong; Yang, Ting; Wang, Lei; Chen, Xin
2017-07-01
To compare the effects of moderate and deep hypothermic circulatory arrest (DHCA) with selective antegrade cerebral perfusion (SACP) during aortic arch surgery in adult patients and to offer the evidence for the detection of the temperature which provides best brain protection in the subjects who accept aortic arch reconstruction surgery. A total of 109 patients undergoing surgery of the aortic arch were divided into the moderate hypothermic circulatory arrest group (Group I) and the deep hypothermic circulatory arrest group (Group II). We recorded the data of the patients and their cardiopulmonary bypass (CPB) time, aortic clamping time, SACP time and postoperative anesthetized recovery time, tracheal intubation time, time in the intensive care unit (ICU) and postoperative neurologic dysfunction. Patient characteristics were similar in the two groups. There were four patients who died in Group II and 1 patient in Group I. There were no significant differences in aortic clamping time of each group (111.4±58.4 vs. 115.9±16.2) min; SACP time (27.4±5.9 vs. 23.5±6.1) min of the moderate hypothermic circulatory arrest group and the deep hypothermic circulatory arrest group; there were significant differences in cardiopulmonary bypass time (207.4±20.9 vs. 263.8±22.6) min, postoperative anesthetized recovery time (19.0±11.1 vs. 36.8±25.3) hours, extubation time (46.4±15.1 vs. 64.4±6.0) hours; length of stay in the intensive care unit (ICU) (4.7±1.7 vs. 8±2.3) days and postoperative neurologic dysfunction in the two groups. Compared to deep hypothermic circulatory arrest, moderate hypothermic circulatory arrest can provide better brain protection and achieve good clinical results.
Aortic Replacement with Sutureless Intraluminal Grafts
Lemole, Gerald M.
1990-01-01
To avoid the anastomotic complications and long cross-clamp times associated with standard suture repair of aortic lesions, we have implanted sutureless intraluminal grafts in 122 patients since 1976. Forty-nine patients had disorders of the ascending aorta, aortic arch, or both: their operative mortality was 14% (7 patients), and the group's 5-year actuarial survival rate has been 64%. There have been no instances of graft dislodgment, graft infection, aortic bleeding, or pseudoaneurysm formation. Forty-two patients had disorders of the descending aorta and thoracoabdominal aorta: their early mortality was 10% (4 patients), and the group's 5-year actuarial survival rate has been 56%. There was 1 early instance of graft dislodgment, but no pseudoaneurysm formation, graft erosion, aortic bleeding, intravascular hemolysis, or permanent deficits in neurologic, renal, or vascular function. Thirty-one patients had the sutureless intraluminal graft implanted in the abdominal aortic position: their early mortality was 6% (2 patients), and the 5-year actuarial survival rate for this group has been 79%. There were no instances of renal failure, ischemic complication, postoperative paraplegia, pseudoaneurysm, or anastomotic true aneurysm. Our recent efforts have been directed toward developing an adjustable spool that can adapt to the widest aorta or the narrowest aortic arch vessel; but in the meanwhile, the present sutureless graft yields shorter cross-clamp times, fewer intraoperative complications, and both early and late results as satisfactory as those afforded by traditional methods of aortic repair. (Texas Heart Institute Journal 1990; 17:302-9) Images PMID:15227522
Dregelid, Einar Børre; Lilleng, Peer Kåre
2016-01-01
When ischemic events ascribable to microembolization occur during open repair of proximal abdominal aortic aneurysms, a likely origin of atheroembolism is not always found. A 78-year old man with enlargement of the entire aorta underwent open repair for a pararenal abdominal aortic aneurysm using supraceliac aortic clamping for 20min. Then the graft was clamped, the supraceliac clamp was removed, and the distal and right renal anastomoses were also completed. The patient was stable throughout the operation with only transient drop in blood pressure on reperfusion. Postoperatively the patient developed ischemia, attributable to microembolization, in legs, small intestine, gall bladder and kidneys. He underwent fasciotomy, small bowel and gall bladder resections. Intestinal absorptive function did not recover adequately and he died after 4 months. Microscopic examination of hundreds of intestinal, juxtaintestinal mesenteric, and gall bladder arteries showed a few ones containing cholesterol emboli. It is unsure whether a few occluded small arteries out of several hundred could have caused the ischemic injury alone. There had been only moderate backbleeding from aortic branches above the proximal anastomosis while it was sutured. Inadvertently, remaining air in the graft, aorta, and aortic branches may have been whipped into the pulsating blood, resulting in air microbubbles, when the aortic clamp was removed. Although both atheromatous particles and air microbubbles are well-known causes of iatrogenic microembolization, the importance of air microembolization in open repair of pararenal aortic aneurysms is not known and need to be studied. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Safety of minimally invasive mitral valve surgery without aortic cross-clamp.
Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Kumar, Sathappan; Solenkova, Nataliya V; Kaiser, Clayton A; Greelish, James P; Balaguer, Jorge M; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Kim, Betty S; Byrne, John G
2008-05-01
We developed a technique for open heart surgery through a small (5 cm) right-anterolateral thoracotomy without aortic cross-clamp. One hundred and ninety-five consecutive patients (103 male and 92 female), age 69 +/- 8 years, underwent surgery between January 2006 and July 2007. Mean preoperative New York Heart Association function class was 2.2 +/- 0.7. Thirty-five patients (18%) had an ejection fraction 0.35 or less. Cardiopulmonary bypass was instituted through femoral (176 of 195, 90%), axillary (18 of 195, 9%), or direct aortic (1 of 195, 0.5%) cannulation. Under cold fibrillatory arrest (mean temperature 28.2 degrees C) without aortic cross-clamp, mitral valve repair (72 of 195, 37%), mitral valve replacement (117 of 195, 60%), or other (6 of 195, 3%) procedures were performed. Concomitant procedures included maze (45 of 195, 23%), patent foramen ovale closure (42 of 195, 22%) and tricuspid valve repair (16 of 195, 8%), or replacement (4 of 195, 2%). Thirty-day mortality was 3% (6 of 195). Duration of fibrillatory arrest, cardiopulmonary bypass, and "skin to skin" surgery were 88 +/- 32, 118 +/- 52, and 280 +/- 78 minutes, respectively. Ten patients (5%) underwent reexploration for bleeding and 44% did not receive any blood transfusions. Six patients (3%) sustained a postoperative stroke, eight (4%) developed low cardiac output syndrome, and two (1%) developed renal failure requiring hemodialysis. Mean length of hospital stay was 7 +/- 4.8 days. This simplified technique of minimally invasive open heart surgery is safe and easily reproducible. Fibrillatory arrest without aortic cross-clamping, with coronary perfusion against an intact aortic valve, does not increase the risk of stroke or low cardiac output. It may be particularly useful in higher risk patients in whom sternotomy with aortic clamping is less desirable.
A Porcine Model for Endolaparoscopic Abdominal Aortic Repair and Endoscopic Training
Zarins, Christopher K.; Daunt, David A.; Coleman, Leslie A.; Saenz, Yamil; Fogarty, Thomas J.; Hermann, George D.; Nezhat, Camran R.; Olsen, Eric K.
2003-01-01
Objective: The goals of this laboratory model were to evaluate the performance of the surgical team and endolaparoscopic techniques in the porcine model of infrarenal abdominal aortic repair. Methods: Twenty-four pigs underwent full endolaparoscopic aorto-aortic graft implantation with voice-activated computerized robotics. The first group of 10 pigs (acute) was sacrificed while under anesthesia at 0.5 hours (5 animals) and 2 hours (5 animals). The second group of 14 pigs (survival) were recovered from anesthesia and maintained for 7 hours (5 pigs) and 7 days (9 pigs) prior to sacrifice. Survival animals were observed for evidence of hind limb dysfunction. All grafts were visually inspected at autopsy. Results: All animals survived the operation. All grafts were successfully implanted, and all were patent with intact anastomoses at autopsy. Mean aortic clamp time for each group was as follows: acute, 92.9±28.04 minutes; survival, 59.6±13.8 minutes; P=0.0008. Total operative time for each group was as follows: acute, 179±39.6 minutes; survival, 164.6±48 minutes; P=0.44 ns. Estimated blood loss for each group was as follows: acute, 214±437.8 mL; survival 169.2±271 mL; P=0.76 ns. The following outcomes were observed: 1 animal died from respiratory arrest; 1 animal suffered motor sensory dysfunction of the hind limbs (spinal cord ischemia); significant bleeding occurred in 6 of 24 pigs; 8 of the 9 seven-day survivors required minimal pain medication and had normal hind limb function. Conclusions: The reduction in aortic clamp time, total operative time, and blood loss as the study progressed indicate the feasibility of this surgical protocol and the maturation of the learning process, which is paramount in prevention of 2 main sources of morbidity: bleeding and spinal cord ischemia. The reduction in aortic clamp time between the acute and survival groups was dramatic and statistically significant. An intensive formal training program combining dry and live surgical laboratories is deemed essential for the development of endoscopic skill sets necessary for this challenging procedure. PMID:12856843
Surgical management of subvalvular aortic stenosis and mitral dysplasia in a golden retriever.
White, R N; Boswood, A; Garden, O A; Hammond, R A
1997-06-01
A 12-month-old neutered male golden retriever was presented with a history of lethargy and exercise intolerance. Clinical examination, electrocardiography, radiography and echocardiography supported a diagnosis of fixed subvalvular aortic stenosis with a Doppler pressure gradient of 77.5 mmHg. Surgical inspection also revealed gross structural abnormalities of the mitral valve consistent with mitral dysplasia. Intervention consisted of resection of the dysplastic mitral valve and the subvalvular aortic stenosis. The mitral valve was replaced with a bioprosthetic valve. Total cardiopulmonary bypass time was 65 minutes and aortic cross-clamp time was 55 minutes. A full recovery was made and 11 months postoperatively the aortic transvalvular gradient was 30 mmHg. At the time of writing, 12 months after surgery, the dog was clinically normal and requires no medication.
Ding, Chao; Wang, Chunmao; Dong, Aiqiang; Kong, Minjian; Jiang, Daming; Tao, Kaiyu; Shen, Zhonghua
2012-05-04
Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case-control study in the published English Journal. 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI -0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI -3.05 to -0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI -2.71 to -0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI -0.81 to 0.04 days, p = 0.08). ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time.
Huynh, Hai; Elkouri, Stephane; Beaudoin, Nathalie; Bruneau, Luc; Guimond, Cathie; Daniel, Véronique; Blair, Jean-François
2007-01-01
This study evaluated the learning curve for a second-year general surgery resident and compared 2 totally laparoscopic aortic surgery techniques in 10 pigs: the transretroperitoneal apron approach and the transperitoneal retrocolic approach. Five end points were compared: success rate, percentage of conversion, time required, laparoscopic anastomosis quality, and learning curve. The first 3 interventions required an open conversion. The last 7 were done without complications. Mean dissection time was significantly higher with the apron approach compared with the retrocolic approach. The total times for operation, clamping, and arteriotomy time were similar. All laparoscopic anastomoses were patent and without stenosis. The initial learning curve for laparoscopic anastomosis was relatively short for a second-year surgery resident. Both techniques resulted in satisfactory exposure of the aorta and similar mean operative and clamping time. Training on an ex vivo laparoscopic box trainer and on an animal model seems to be complementary to decrease laparoscopic anastomosis completion time.
Hemiarch Reconstruction Vs Clamped Aortic Anastomosis for Concomitant Ascending Aortic Aneurysm.
Sultan, Ibrahim; Bianco, Valentino; Yajzi, Ibrahim; Kilic, Arman; Dufendach, Keith; Cardounel, Arturo; Althouse, Andrew D; Masri, Ahmad; Navid, Forozan; Gleason, Thomas G
2018-05-03
Deep hypothermic circulatory arrest (DHCA) is often avoided in patients with concomitant ascending aortic pathology when treating other cardiac disease to avoid increased risk of morbidity and mortality. We hypothesized that the use of DHCA with retrograde cerebral perfusion (RCP) does not add incremental risk to ascending aortic replacement alone in the setting of concomitant cardiac surgery. 408 ascending aortic ± hemiarch replacements and aortic (root)/mitral/tricuspid valve(s), CABG, or MAZE procedures were performed for concomitant cardiac disease. DHCA with RCP was used for all hemiarch replacements or the ascending aorta was replaced with an aortic cross-clamp proximal to the innominate artery. Propensity-score matching was used to match similar ascending patients vs. hemiarch patients; the final propensity score matched patients on age, gender, BMI, previous heart surgery, pre-op aortic insufficiency, pre-op aortic stenosis, pre-op EF, and operative variables. Propensity-score matching yielded 116 pairs of Non-hemiarch patients vs. 116 hemiarch patients. Within the propensity-score matched cohort, there were no differences in postoperative stroke (1.7% vs. 3.4%, p = 0.41), new postoperative dialysis (6.0% vs. 5.2%, p = 0.78), postoperative renal insufficiency (27.6% vs. 19.8%, p = 0.16), 30-day mortality (2.6% vs. 3.4%, p = 0.701), or 1-year mortality (4.3% vs. 4.3%, p = 1.00) CONCLUSIONS: Hemiarch replacement using DHCA with RCP does not increase the risk of operative complications compared to a normothermic, clamped-distal aortic anastomosis, and therefore its use should not be limited when planning complex multi-procedural reconstructions during elective ascending thoracic aortic replacement with concomitant cardiac surgery. Copyright © 2018. Published by Elsevier Inc.
Garlicki, Miroslaw; Roguski, K; Puchniewicz, M; Ehrlich, Marek P
2006-08-01
We report in this study our results with composite aortic root replacement (CVR) using the classic or modified Cabrol coronary implantation technique. From October 2001 to March 2005, 25 patients underwent aortic root replacement. In all cases, the indication for surgery was a degenerative aneurysm with a diameter of more than 6 cm. Seven patients had undergone a previous aortic operation on the ascending aorta. Mean age was 53+/-13 years and 22 patients were male. Mean Euroscore was 5.2+/-2.4. Aortic insufficiency was present in all patients. Two patients had Marfan syndrome. The 30-day mortality was 0%. Two patients required profound hypothermic circulatory arrest. Mean aortic cross-clamp time was 91+/-24 minutes and the mean circulatory arrest time was 24+/-15 minutes. No patients developed a pseudoaneurysm after the operation. We conclude that composite aortic root replacement with the classic or modified Cabrol technique results in a low operative mortality. However, it should be only used when a "button" technique is not feasible.
Early Outcomes of Sutureless Aortic Valves.
Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat
2016-06-01
In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.
Early Outcomes of Sutureless Aortic Valves
Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat
2016-01-01
Background In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time. PMID:27298793
2012-01-01
Background Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case–control study in the published English Journal. Methods 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. Results ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI −0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI −3.05 to −0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI −2.71 to −0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI −0.81 to 0.04 days, p = 0.08). Conclusion ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time. PMID:22559820
Maeda, Takuma; Hattori, Kohshi; Sumiyoshi, Miho; Kanazawa, Hiroko; Ohnishi, Yoshihiko
2018-06-01
The fourth-generation FloTrac/Vigileo™ improved its algorithm to follow changes in systemic vascular resistance index (SVRI). This revision may improve the accuracy and trending ability of CI even in patients who undergo abdominal aortic aneurysm (AAA) surgery which cause drastic change of SVRI by aortic clamping. The purpose of this study is to elucidate the accuracy and trending ability of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery by comparing the FloTrac/Vigileo™-derived CI (CI FT ) with that measured by three-dimensional echocardiography (CI 3D ). Twenty-six patients undergoing elective AAA surgery were included in this study. CI FT and CI3 D were determined simultaneously in eight points including before and after aortic clamp. We used CI 3D as the reference method. In the Bland-Altman analysis, CI FT had a wide limit of agreement with CI 3D showing a percentage error of 46.7%. Subgroup analysis showed that the percentage error between CO 3D and CO FT was 56.3% in patients with cardiac index < 2.5 L/min/m 2 and 28.4% in patients with cardiac index ≥ 2.5 L/min/m 2 . SVRI was significantly higher in patients with cardiac index < 2.5 L/min/m 2 (1703 ± 330 vs. 2757 ± 798; p < 0.001). The tracking ability of fourth generation of FloTrac/Vigileo™ after aortic clamp was not clinically acceptable (26.9%). The degree of accuracy of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery was not acceptable. The tracking ability of the fourth-generation FloTrac/Vigileo™ after aortic clamp was below the acceptable limit.
Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker
2018-02-01
In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.
Which aortic clamp strategy is better to reduce postoperative stroke and death
Chen, Liyu; Hua, Xiumeng; Song, Jiangping; Wang, Liqing
2018-01-01
Abstract Background: Stroke is severe complication of coronary artery bypass grafting (CABG) which may be associated with clamp strategy, there are 2 strategies to clamp aorta including single aortic clamp (SAC) and partial aortic clamp (PAC). It is controversial that which clamping strategy is better to reduce the postoperative stroke and death, so this study aims to investigate which is better for reducing postoperative stroke and death within 30 days. Methods: We collected 469 patients who had on-pump CABG in Fuwai Hospital during January 2014 to July 2015. The SAC group consisted of 265 patients while the PAC group included 204 patients. We compared the 2 group patient difference. At the same time, 12 studies were identified by systematic search. The odds ratio (OR) was used as effect index to compare SAC and PAC strategy by fix-effect modeling. We also tested heterogeneity and publication bias. The primary end point of study was occurrence of postoperative stroke within 30 days of operation, the second end point of study was the incidence of 30-day mortality. Results: The single center retrospective study showed that the patients in the SAC group were older than those in the PAC group (62.5 ± 8.1 vs 60.3 ± 8.0 years, P = .01). The proportions of peripheral vascular disease and hypertension of SAC were higher than PAC (71 (26.8%) versus 36 (17.6%), P = .02; 183 (69.1%) versus 115 (56.4%), P = .01, respectively). Besides, the number of vascular anastomosis was more in the SAC group (3.29 ± 0.74 versus 2.97 ± 0.974, P < .001). The linear-regression analysis suggested that the time of cardiopulmonary bypass of SAC was shorter than the PAC group (93.2 ± 22.4 vs.103.4 ± 26.8 minutes, P-regression < .001) and postoperative death within 30-days was similar (1 (0.4%) vs. 2 (1.0%), P-regression = .47). There was no stroke occurring in both the groups. And the meta-analysis suggested the postoperative stroke and death within 30-days were similar between SAC group and PAC group (OR: 0.78, 95% CI: 0.58–1.06; OR: 0.82, 95% CI: 0.61–1.10; respectively). Moreover, subgroup meta-analysis also had the same results. Conclusion: There was no significant difference between SAC and PAC clamping strategy on postoperative stroke and death within 30-days; however, SAC can reduce the usage time of cardiopulmonary bypass. PMID:29561451
Baraki, Hassina; Al Ahmad, Ammar; Sarikouch, Samir; Koigeldiev, Nurbol; Khaladj, Nawid; Hagl, Christian; Pichlmaier, Maximillian; Haverich, Axel; Shrestha, Malakh
2010-05-01
Composite replacement is the standard treatment for the repair of aortic aneurysm with aortic valve pathology. With improved long-term durability and no requirement for long-term anticoagulation, tissue-valved conduits have become increasingly popular. Herein are reported the results achieved with 50 consecutive 'Bentall' operations, using the first commercially available prefabricated stentless tissue-valved conduit (Vascutek BioValsalva). Between September 2007 and September 2009, a total of 50 patients (10 females, 40 males; mean age 65 +/- 7 years) received a BioValsalva conduit. Concomitant procedures included coronary artery bypass grafting (CABG; n = 15), other valve (n = 5), and aortic arch replacement with circulatory arrest (n = 20; three of these had an additional frozen elephant trunk). Four of the procedures were re-operations. A six-month follow up with echocardiography and clinical examination was completed in 25 patients. The 30-day mortality was 8% (4/50). Three of these patients underwent concomitant procedures. The cardiopulmonary bypass (CPB) and cross-clamp times were 178 +/- 30 min and 106 +/- 7 min, respectively. The triple-layered vascular graft proved to be hemostatic, without suture-line bleeding. Both, the initial and follow up echocardiography showed no valvular insufficiency, with a mean gradient of 13 +/- 5 mmHg. All patients were in NYHA class I-II. The BioValsalva prefabricated tissue-valved conduit showed very good early results. The ischemic time required to construct a 'home-made' stentless tissue-valved conduit was eliminated, thus reducing the cross-clamp time. The conduit also offered the hemodynamic advantages of a stentless valve.
Surgical outcome of traumatic aortic disruption of the thoracic aorta in Songklanagarind Hospital.
Chittithavorn, Voravit; Vasinanukorn, Prasert; Rergkliang, Chareonkiat; Chetpaophan, Apirak
2004-09-01
This retrospective study collected data from 11 patients who underwent TDTA' repair from February 1987 to June 2003, 10 patients were men (90.9%) and 1 was a woman (9.09%) with a mean age of 32 years. All patients had a blunt injury from a violent motor vehicle accident. None of them required thoracotomy at the emergency room. Standard chest x-ray was done in every patient and the widening of the upper mediastinum was mainly found in 10 patients (90.9%), hemothorax in 8 patients, blurred aortic knob in 7 patients, lower left main bronchus in 3 patients, pleural apical cap in 2 patients and pneumothorax in 1 patient, 8 patients were investigated by CT scan and presented a positive study. 3 patients (27.27%) were diagnosed by both aortogram and CT scan anda pseudo-false aneurysm was found Multi organ system injury was mainly found in 10 patients (90.91%). 7 patients (63.64%) had hypovolumic shock on admission, 3 patients died postoperation and 2 of them had experience of postoperative paraplegia. Clamp and sew technique was used in 6 patients (54.54%). The duration of aortic cross clamp time ranged from 19-67 minutes (mean time = 39.30 min.) Pneumonia was the significant postoperative complication found in 3 patients, including acute renal failure, ARDS (all died) and paraplegia in 2 patients. The duration of the aortic cross clamp time that was used in the patients who presented with paraplegia was more than 40 minutes. 1 patient had delayed the aortic repair for 3 weeks resulting from severe brain contusion. 5 patients (45.45%) died in hospital. 1 patient died in the operating theatre, 4 of them (36.36%) died during postoperatively within 24 hours. The mainly cause of death which occurred in every patient was intraoperative cardiac arrest, the others were postoperative bleeding, ARDS and arrhythmias. The mean of length of stay in the intensive care unit was 6.94 days. The period of hospitalization ranged from 11 to 180 days (mean = 62.83 days). The small sample size is the limitation for the present study. The authors plan to do prospective study about the factors which influence the mortality rate and factors related to postoperative paraplegia in TDTA patients at Songklanakarind Hospital.
Aortic Baroreceptors Display Higher Mechanosensitivity than Carotid Baroreceptors.
Lau, Eva On-Chai; Lo, Chun-Yin; Yao, Yifei; Mak, Arthur Fuk-Tat; Jiang, Liwen; Huang, Yu; Yao, Xiaoqiang
2016-01-01
Arterial baroreceptors are mechanical sensors that detect blood pressure changes. It has long been suggested that the two arterial baroreceptors, aortic and carotid baroreceptors, have different pressure sensitivities. However, there is no consensus as to which of the arterial baroreceptors are more sensitive to changes in blood pressure. In the present study, we employed independent methods to compare the pressure sensitivity of the two arterial baroreceptors. Firstly, pressure-activated action potential firing was measured by whole-cell current clamp with a high-speed pressure clamp system in primary cultured baroreceptor neurons. The results show that aortic depressor neurons possessed a higher percentage of mechano-sensitive neurons. Furthermore, aortic baroreceptor neurons show a lower pressure threshold than that of carotid baroreceptor neurons. Secondly, uniaxial stretching of baroreceptor neurons, that mimics the forces exerted on blood vessels, elicited a larger increase in intracellular Ca(2+) rise in aortic baroreceptor neurons than in carotid baroreceptor neurons. Thirdly, the pressure-induced action potential firing in the aortic depressor nerve recorded in vivo was also higher. The present study therefore provides for a basic physiological understanding on the pressure sensitivity of the two baroreceptor neurons and suggests that aortic baroreceptors have a higher pressure sensitivity than carotid baroreceptors.
Facilitating Hemostasis After Proximal Aortic Surgery: Results of The PROTECT Trial.
Khoynezhad, Ali; DelaRosa, Jacob; Moon, Marc R; Brinkman, William T; Thompson, Richard B; Desai, Nimesh D; Malaisrie, S Chris; Girardi, Leonard N; Bavaria, Joseph E; Reece, T Brett
2018-05-01
This study intended to evaluate the safety and hemostatic efficacy of a novel vascular sealant (Tridyne; Neomend, Inc, Irvine, CA) compared with an accepted adjunctive hemostatic agent applied to aortotomy and sutures lines in cardiovascular operations. Patients undergoing aortic valve replacement, ascending aortic replacement, or aortic root replacement were randomly assigned 2:1 to Tridyne (n = 107) or Gelfoam Plus (Baxter Healthcare Corp, Hayward, CA) (n = 51). These groups were similar with regard to age, sex, race, medical history, duration of bypass and cross-clamping, and number of suture lines treated. Suture lines were treated after confirmation of some leakage but before formal removal of the clamp. The median bleeding time was significantly lower for Tridyne versus Gelfoam Plus (0 versus 10.0 minutes, p < 0.0001). Immediate hemostasis was achieved in 59.4% of the Tridyne group versus 16.0% of Gelfoam Plus group (p < 0.0001). A significantly greater proportion of patients in the Tridyne group achieved successful hemostasis at the aortic suture line than patients in the Gelfoam Plus group (85.7% versus 40.0%, p < 0.0001). The Clinical Events Committee adjudicated 7 patients with possible device-related serious adverse events: 3 patients (2.9%) in the Tridyne group and 4 patients (8.2%) in the Gelfoam Plus group (p = 0.2097). Tridyne was safe and effective when used as an adjunct to conventional hemostasis to treat high-pressure vessels in patients who receive anticoagulation agents, in reducing time to hemostasis, and in promoting both immediate and persistent hemostasis. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Myocardial Oxidative Stress in Infants Undergoing Cardiac Surgery.
Sznycer-Taub, Nathaniel; Mackie, Stewart; Peng, Yun-Wen; Donohue, Janet; Yu, Sunkyung; Aiyagari, Ranjit; Charpie, John
2016-04-01
Cardiac surgery for congenital heart disease often necessitates a period of myocardial ischemia during cardiopulmonary bypass and cardioplegic arrest, followed by reperfusion after aortic cross-clamp removal. In experimental models, myocardial ischemia-reperfusion is associated with significant oxidative stress and ventricular dysfunction. A prospective observational study was conducted in infants (<1 year) who underwent elective surgical repair of a ventricular septal defect (VSD) or tetralogy of Fallot (TOF). Blood samples were drawn following anesthetic induction (baseline) and directly from the coronary sinus at 1, 3, 5, and 10 min following aortic cross-clamp removal. Samples were analyzed for oxidant stress using assays for thiobarbituric acid-reactive substances, protein carbonyl, 8-isoprostane, and total antioxidant capacity. For each subject, raw assay data were normalized to individual baseline samples and expressed as fold-change from baseline. Results were compared using a one-sample t test with Bonferroni correction for multiple comparisons. Sixteen patients (ten with TOF and six with VSD) were enrolled in the study, and there were no major postoperative complications observed. For the entire cohort, there was an immediate, rapid increase in myocardial oxidative stress that was sustained for 10 min following aortic cross-clamp removal in all biomarker assays (all P < 0.01), except total antioxidant capacity. Infant cardiac surgery is associated with a rapid, robust, and time-dependent increase in myocardial oxidant stress as measured from the coronary sinus in vivo. Future studies with larger enrollment are necessary to assess any association between myocardial oxidative stress and early postoperative outcomes.
Left atriotomy versus right atriotomy trans-septal approach for left atrial myxoma.
Hatemi, A C; Gürsoy, M; Tongut, A; Kiliçkesmez, K; Karaoğlu, K; Küçükoğlu, S; Kansiz, E
2010-01-01
The biatrial approach has been the classic means of access for left atrial myxoma resection. Increased surgical experience led cardiac surgeons to favour the uniatrial approach to reduce incisions and achieve adequate exposure. In this study, two unilateral surgical approaches were compared in 18 consecutive left atrial myxoma cases. Patients were divided into two groups according to the surgical approach: left atriotomy (group 1, n = 9) and right atriotomy trans-septal approach (group 2, n = 9). Comparison criteria included pre- and post-operative functional capacity, cardiac rhythm, left ventricular ejection fraction, pulmonary artery pressure, left atrial dimensions, cardiopulmonary bypass time, aortic cross-clamp time, drainage over 48 h post-operatively, units of blood transfused, extubation time and length of stay in the intensive care unit and hospital. No significant between-group difference was observed in any criteria except aortic cross-clamp time, which was significantly longer in group 2 than in group 1. No recurrence of myxoma occurred in either group for the 15 patients followed up. Right atrial trans-septal incision appears to be as safe and effective as the left atriotomy approach for left atrial myxoma resection.
Double-arterial cannulation for aortic valve replacement with porcelain aorta.
De Paulis, Ruggero; Maselli, Daniele; Scaffa, Raffaele; Nardella, Saverio
2009-10-01
We describe a new technique of aortic valve replacement (AVR) in patients with porcelain aorta. Three patients (mean age 75 years) were treated. The cardiopulmonary bypass (CPB) was established after side-graft right axillary artery and direct femoral artery cannulation. Venous drainage was obtained by atrio-caval cannulation. The procedures were performed in mild hypothermia (30 degrees C). Cerebral perfusion was carried out by clamping the innominate artery and all epiaortic vessels. The aorta was endoclamped by a Foley balloon inserted into the isthmus. The aorta was then opened longitudinally for 10 cm to expose and replace the aortic valve. Near-infra-red spectroscopy (NIRS) and bilateral radial artery pressure were used to monitor effective cerebral perfusion. Operative mortality was absent. The mean time of CPB was 73 min. NIRS-derived tissue oxygenation was maintained above 55%. Postoperative course was uneventful. This technique has several advantages: first, the cannulation of right axillary and the common femoral artery allows simultaneous cerebral and systemic perfusion. Second, any form of cross-clamp is avoided and the aorta is occluded away from the epiaortic vessels. Third, there is an increased freedom to choose the best place for aortotomy.
Waked, Karl; Schepens, Marc
2018-01-01
During open thoracoabdominal aortic aneurysm repair (OTAAAR), there is an inevitable organ ischemic period that occurs when the abdominal arteries are being reattached to the aortic graft. Despite various protective techniques, the incidence of renal and visceral complications remains substantial. This state-of-the-art review gives an overview of the current and most evidence-based organ protection methods during OTAAAR, based on the most recent publications and personal experience. An electronic search was performed in four medical databases, using the following MeSH terms: thoracoabdominal aneurysm, TAAAR, visceral protection, renal protection, kidney, perfusion, and intestines. Every publication type was considered. The literature search was ended on August 31st, 2017. The left heart bypass (LHB) is currently the most frequent adjunct to provide distal aortic perfusion (DAP) during aortic clamping. Together with systemic hypothermia, it forms the cornerstone in organ protection during aortic clamping. Further renal protection can be obtained by selective renal perfusion (SRP) with cold blood or cold crystalloid solution, the latter enriched with mannitol. The perfusion should be administered in a volume- and pressure-controlled way and, if possible, by use of a pulsatile pump. Selective visceral perfusion (SVP) is not routinely used, as it does not provide adequate blood flow for visceral protection. The best way to protect the intestines is by minimizing the ischemic time. The preservation of renal and visceral function after OTAAAR can only be obtained with specific strategies before, during, and after the operation. This involves a series of measures, including selective digestive decontamination (SDD), avoidance of nephrotoxic drugs, minimizing the renal and intestinal ischemic time, systemic cooling, avoidance of hemodynamic instability, and regional protective perfusion of the kidneys. Future innovations in catheters, cardiac bypass flow types, mechanical components, hybrid vascular grafts, and pharmaceutical protection measures will hopefully further reduce organ complications.
Recent Developments in Minimally Invasive Cardiac Surgery: Evolution or Revolution?
Marullo, Antonino G M; Irace, Francesco G; Vitulli, Piergiusto; Peruzzi, Mariangela; Rose, David; D'Ascoli, Riccardo; Iaccarino, Alessandra; Pisani, Angelo; De Carlo, Carlotta; Mazzesi, Giuseppe; Barretta, Antonio; Greco, Ernesto
2015-01-01
Intraluminal aortic clamping has been achieved until now by means of a sophisticated device consisting of a three-lumen catheter named Endoclamp, which allows at the same time occlusion of the aorta, antegrade delivering of cardioplegia, and venting through the aortic root. This tool has shown important advantages allowing aortic occlusion and perfusate delivering without a direct contact with ascending aorta reducing meanwhile the risk of traumatic and/or iatrogenic injuries. Recently, a new device (Intraclude catheter) with the same characteristics and properties has been proposed and introduced in clinical practice. The aim of this paper is to investigate the differences between Endoclamp and Intraclude catheters and to analyze the advantages advocated by this new device for intraluminal aortic occlusion since it is noticeable as these new technological tools are gaining more and more attractiveness due to their appraised clinical efficacy.
Boethig, D; Minami, K; Lueth, J-U; El-Banayosy, A; Breymann, T; Koerfer, R
2004-06-01
The ideal myocardial protection during isolated CABG is still a matter of debate. Cardioplegia versus intermittent aortic cross-clamping (IACC) are the main opponents; the following article shows that IACC can be safe, efficient and might be cheaper than cardioplegia. Demographics and co-morbidities of 15307 CABG only patients consecutively operated on between January 1993 and October 2001 in the Heart Center in Bad Oeynhausen were assessed by the German Quality Assurance data set and risk-stratified using the EuroSCORE. Outcome (30-day or in-hospital mortality) was compared to the expected EuroSCORE estimation. Expected mortality was 3.25 %, observed mortality was 1.3 %, being significantly lower in the low, medium as well as high risk patients subgroup. Complication rates increased steadily with expected mortality rates. Stroke and myocardial infarction rates for patients with peripheral vessel disease were not higher than in comparable studies. More than 1000000 EUR were saved by lower cardioplegia bills. Myocardial protection with intermittent aortic cross-clamping for isolated CABG can be safe, effective, and economically advantageous when compared to cardioplegic solutions.
Miskolczi, Szabolcs; Vaszily, Miklós; Papp, Csaba; Péterffy, Arpád
2008-01-01
Haemorrhagic complications significantly increase mortality and cost of treatment in cardiac surgery. A few years ago recombinant activated factor VII has been introduced to decrease such complications. In our department recombinant activated factor VII has been used in 11 patients between 2004 and 2007. Nine of them underwent a combined (simultaneous CABG and valve replacement) high risk surgery with long aortic cross clamp time and long extracorporeal circulation time. One patient underwent a repeat coronary artery bypass operation and one was operated for aortic dissection. The average dose given was 6.5 mg (2.4-9.6 mg). The average amount of bleeding without NovoSeven given was 5440 ml, however it was only 987 ml when NovoSeven was used. Nine of the patients were completely recovered and discharged from hospital, but two of them died in the postoperative period for delayed use of the recombinant factor VII-a and for severe co-morbidities (bowel ischaemia, cirrhosis of the liver). NovoSeven given in the proper time and dose significantly reduces bleeding following cardiac surgery, even if it cannot be stopped surgically. Using recombinant factor VIIa can save life in case of severe non-surgical diffuse bleeding or in case of suture insufficiency caused by friable soft tissues following high risk combined surgery with extremely long aortic cross clamp time and extracorporeal circulation time. Significant delay in the use of NovoSeven should be avoided because the temporary reduction of bleeding usually does not change fatal outcome.
Aortic Valve Replacement With the Stentless Freedom SOLO Bioprosthesis: A Systematic Review.
Wollersheim, Laurens W; Li, Wilson W; Bouma, Berto J; Repossini, Alberto; van der Meulen, Jan; de Mol, Bas A
2015-10-01
This systematic review examined the clinical and hemodynamic performance of the stentless Freedom SOLO (Sorin Group, Milan, Italy) aortic bioprosthesis. The occurrence of postoperative thrombocytopenia was also analyzed. The Freedom SOLO is safe to use in everyday practice, with short cross-clamp times, and postoperative pacemaker implantation is notably lower. Valvular gradients are low and remain stable during short-term follow-up. Thrombocytopenia is more severe than in other aortic prostheses; however, this is without clinical consequences. Within a few years, the 15-year follow-up of this bioprosthesis will be known, which will be key to evaluating its long-term durability. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ye, Jian; Webb, John G
2014-12-01
We report our first-in-human clinical experience in the use of the new version of the EMBOL-X intra-aortic filter (Edwards Lifesciences Corporation, Irvine, Calif) to capture embolic material during transaortic transcatheter aortic valve implantation and cardiac surgery. Five patients were enrolled into the first-in-human clinical assessment of the new version of the EMBOL-X intra-aortic filter. Three patients underwent coronary artery bypass grafting, and 2 patients underwent transaortic transcatheter aortic valve implantation. During coronary artery bypass grafting, the filter was deployed before clamping of the aorta and removal of the aortic clamp. In contrast, the filter was deployed before aortic puncture for transaortic transcatheter aortic valve implantation and kept in the aorta throughout the entire procedure. The filter introducer sheath and filter were easily placed and removed without difficulty. There were no complications related to the use of the filter. Postoperative examination of the retrieved filters revealed the presence of multiple microemboli in the filters from all 5 cases. Histologic study revealed various kinds of tissue and thrombus. This first-in-human clinical experience has demonstrated the safety and feasibility of using the new version of the EMBOL-X intra-aortic filter during either cardiac surgery or transaortic transcatheter aortic valve implantation. We believe that the combination of the transaortic approach without aortic arch manipulation and the use of the EMBOL-X filter with a high capture rate is a promising strategy to reduce the incidence of embolic complications during transcatheter aortic valve implantation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Perioperative management of calves undergoing implantation of a left ventricular assist device.
Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J
2000-01-01
To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.
Extra-Anatomic Revascularization of Extensive Coral Reef Aorta.
Gaggiano, Andrea; Kasemi, Holta; Monti, Andrea; Laurito, Antonella; Maselli, Mauro; Manzo, Paola; Quaglino, Simone; Tavolini, Valeria
2017-10-01
Coral reef aorta (CRA) is a rare, potential lethal disease of the visceral aorta as it can cause visceral and renal infarction. Various surgical approaches have been proposed for the CRA treatment. The purpose of this article is to report different extensive extra-anatomic CRA treatment modalities tailored on the patients' clinical and anatomic presentation. From April 2006 to October 2012, 4 symptomatic patients with extensive CRA were treated at our department. Extra-anatomic aortic revascularization with selective visceral vessels clamping was performed in all cases. Technical success was 100%. No perioperative death was registered. All patients remained asymptomatic during the follow-up period (62, 49, 25, and 94 months, respectively), with bypasses and target vessels patency. The extra-anatomic bypass with selective visceral vessels clamping reduces the aortic occlusion time and the risk of organ ischemia. All approaches available should be considered on a case-by-case basis and in high-volume centers. Copyright © 2017 Elsevier Inc. All rights reserved.
Oxidant-Antioxidant Balance during On-Pump Coronary Artery Bypass Grafting
Mentese, Umit; Dogan, Orhan Veli; Turan, Ibrahim; Usta, Sefer; Dogan, Emre; Oztas Mentese, Seda; Demir, Selim; Ozer, Tanil; Aykan, Ahmet Cagri; Alver, Ahmet
2014-01-01
Backround. The aim of this study was to evaluate the changes in perioperative oxidant-antioxidant balance in ONCABG. Methods. Twenty-three patients were included in this study. Serum total oxidant status (TOS), total antioxidant status (TAS), and oxidative stress index (OSI) values were assessed preoperatively, at 20 minutes after aortic clamping and at 30 minutes, 6 hours, and 48 hours after declamping (reperfusion). The patients were divided into 2 groups according to the median aortic cross clamping (XC) time: group 1 (XC time < 42 minutes) and group 2 (XC time ≥ 42 minutes). Results. TOS and OSI values of whole patients at 30 minutes after reperfusion were higher than preoperative values (P = 0.045, P = 0.015), while perioperative TAS levels of the patients were similar to the preoperative levels (P = 0.173). XC time was correlated with TOS levels at 30 minutes after reperfusion (r = 0.43, P = 0.041). In group 2, TOS and OSI values at 30 minutes after reperfusion were higher than preoperative values (P = 0.023, P = 0.048), whereas a significant difference was not found in group 1 (P = 0.601, P = 0.327). Conclusions. Oxidative imbalance and increase in TOS at reperfusion in ONCABG may be associated with XC time. PMID:25302318
Recent Developments in Minimally Invasive Cardiac Surgery: Evolution or Revolution?
Marullo, Antonino G. M.; Irace, Francesco G.; D'Ascoli, Riccardo; Iaccarino, Alessandra; Pisani, Angelo; De Carlo, Carlotta; Mazzesi, Giuseppe; Barretta, Antonio; Greco, Ernesto
2015-01-01
Intraluminal aortic clamping has been achieved until now by means of a sophisticated device consisting of a three-lumen catheter named Endoclamp, which allows at the same time occlusion of the aorta, antegrade delivering of cardioplegia, and venting through the aortic root. This tool has shown important advantages allowing aortic occlusion and perfusate delivering without a direct contact with ascending aorta reducing meanwhile the risk of traumatic and/or iatrogenic injuries. Recently, a new device (Intraclude catheter) with the same characteristics and properties has been proposed and introduced in clinical practice. The aim of this paper is to investigate the differences between Endoclamp and Intraclude catheters and to analyze the advantages advocated by this new device for intraluminal aortic occlusion since it is noticeable as these new technological tools are gaining more and more attractiveness due to their appraised clinical efficacy. PMID:26636099
Pharmacokinetics of fentanyl in patients undergoing abdominal aortic surgery.
Hudson, R J; Thomson, I R; Cannon, J E; Friesen, R M; Meatherall, R C
1986-03-01
The authors determined the pharmacokinetics of fentanyl 100 micrograms X kg-1 iv in patients undergoing elective abdominal aortic surgery. The mean (+/- SD) age of the ten patients was 67.2 +/- 8.7 yr; their mean weight was 78.5 +/- 13.7 kg. Seven patients had aortic aneurysm repair, and the other three patients had aortobifemoral grafts. Serum fentanyl concentrations were determined from samples drawn at increasing intervals over a 24-h period. A three-compartment pharmacokinetic model was fit to the concentration versus time data. Total drug clearance was 9.8 +/- 1.8 ml X min-1 X kg-1. The volume of distribution at steady-state (Vdss) was 5.4 +/- 1.9 X 1 kg-1. Elimination half-time was 8.7 +/- 2.5 h. There were no significant correlations between these pharmacokinetic parameters and patient's age, duration of aortic cross-clamping, duration of surgery, intraoperative blood loss, or volume of iv fluids given intraoperatively. In healthy volunteers or patients undergoing general surgery, other investigators report mean elimination half-times for fentanyl ranging from 1.7 to 4.4 h. The prolonged elimination half-time in patients having abdominal aortic surgery has important clinical implications. In particular, recovery from large doses will take much longer than would have been anticipated from previously published fentanyl pharmacokinetic data.
Nollo, Giandomenico; Ferrari, Paolo; Graffigna, Angelo C
2011-01-01
The effect on acid-base balance efficacy of intermittent warm and cold blood cardioplegia (IWBC, ICBC) was assessed in 44 patients who underwent cardiac surgery with prolonged aortic cross clamping. With this purpose a customized multi sensor probe was inserted in the coronary sinus, and pH, PO(2), PCO(2) and temperature were continuously measured at 1 Hz sampling rate. The mean cross-clamping time was of 76 ± 26 min on 19 IWBC cases and of 80 ± 24 min on 14 ICBC cases. With IWBC perfusion, at the end of every ischemic period, the lowest pH and PO(2) progressively decreased and the maximal PCO(2) increased. During ICBC the minimum of pH and PO(2) and maximum of PCO2 at the end of different ischemic period during time were constant, also during long cross-clamping time. With IWBC, myocardial ischemia seemed not completely reversed by standardized reperfusions, as reflected by steady deterioration of PCO(2) and pH after each reperfusion.
Aortic valve replacement using continuous suture technique in patients with aortic valve disease.
Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku
2013-08-01
The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.
External aortic wrap for repair of type 1 endoleak☆
Dean, Anastasia; Yap, Swee Leong; Bhamidipaty, Venu; Pond, Franklin
2014-01-01
INTRODUCTION Type 1 endoleak is a rare complication after endovascular abdominal aortic aneurysm repair (EVAR) with a reported frequency up to 2.88%. It is a major risk factor for aneurysmal enlargement and rupture. PRESENTATION OF CASE We present a case of a 68 year old gentleman who was found to have a proximal type 1 endoleak with loss of graft wall apposition on routine surveillance imaging post-EVAR. An initial attempt at endovascular repair was unsuccessful. Given the patient's multiple medical co-morbidities, which precluded the possibility of conventional graft explantation and open repair, we performed a novel surgical technique which did not require aortic cross-clamping. A double-layered Dacron wrap was secured around the infra-renal aorta with Prolene sutures, effectively hoisting the posterior bulge to allow wall to graft apposition and excluding the endoleak. Post-operative CT angiogram showed resolution of the endoleak and a stable sac size. DISCUSSION Several anatomical factors need to be considered when this technique is proposed including aortic neck angulation, position of lumbar arteries and peri-aortic venous anatomy. While an external wrap technique has been investigated sporadically for vascular aneurysms, to our knowledge there is only one similar case in the literature. CONCLUSION Provided certain anatomical features are present, an external aortic wrap is a useful and successful option to manage type 1 endoleak in high-risk patients who are unsuitable for aortic clamping. PMID:25217878
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ito, Hisao; Yamada, Takayuki; Ishibashi, Tadashi
A 65-year-old man underwent a thromboexclusionoperation for management of chronic Stanford type B dissecting aneurysmin 1991. However, long-term follow-up CT scans after the operation revealed that the ascending aorta gradually enlarged and was eventually complicated by recurrent aortic dissection. The patient complained of frequent bloody sputum, whereas chest roentogenography showed no pulmonary abnormalities. Subsequent swallow esophagogram demonstrated that the upper esophagus was deviated to the right and the middle esophagus was greatly compressed by the aortic clamp. Esophageal endoscopy showed a bloody inner surface and marked swelling of the middle esophagus. The patient eventually died of massive hematemesis in 2001.more » We describe the imaging features of unanticipated complications such as recurrent dissecting aneurysm or impending esophageal rupture.Furthermore, we discuss the cause of hematemesis and document that the aortic clamp migrated and resulted in development of a recurrent aneurysmal dissection, which in turn resulted in esophageal rupture with aneurysmal disruption.« less
Combined repair of adult coarctation of the aorta and aortic valvular stenosis.
Ivert, T; Busund, R; Avenarius, D; Dahi, P E
2000-06-01
A 57-year-old man with a high-grade aortic stenosis and aortic coarctation was treated with concomitant valve replacement and insertion of a conduit from the ascending aorta to the retrocardiac descending aorta via the left pleura. Because heart failure has been reported shortly after cardiopulmonary bypass using this technique, the conduit was initially clamped until the postrepair haemodynamics was stable. Computed tomography after 14 months verified patency of the shunt.
Najafi, H; Veeragandham, R
1997-08-01
On three occasions during operations for aortic aneurysm involving the ascending aorta it was noted that upon the release of the aortic clamp the grafted segment remained collapsed, indicating very little or no flow reaching the lumen of the reconstructed aorta. This was promptly and successfully remedied in 2 patients by perfusing the graft directly with a pediatric arterial catheter attached to a pump head while the femoral arterial line maintained systemic arterial inflow. This simple, safe, and highly effective technique adds to the surgeon's repertoire to manage yet another intriguing intraoperative development during thoracic aortic operations.
Regional cerebral perfusion for surgical correction of neonatal aortic arch obstruction.
Zhang, Hui; Cheng, Pei; Hou, Jia; Li, Lei; Liu, Hu; Liu, Ruifang; Ji, Bingyang; Luo, Yi
2009-05-01
One-stage repair of aortic arch obstruction and associated cardiac anomalies is a surgical challenge in infants.The purpose of the present study is to review the current outcome using regional cerebral perfusion (RCP) during a procedure correcting interrupted aortic arch (IAA) and also isolated aortic coarctation (CoA) and CoA combined with hypoplastic aortic arch (CoA-HyAA) in our center. Between January 2007 and July 2008, 24 infant patients with interrupted aortic arch (IAA) (n=3), isolated aortic coarctation (iCoA) (n=9) and aortic coarctation with hypoplastic aortic arch (CoA-HyAA) (n=12) underwent one-stage surgical correction in our hospital. End-to-end anastomosis was employed in 12 infants (IAA n=3 and iCoA n=9); for the other 12 patients with CoA-HyAA, an end-to-end extended anastomosis was used in 8 cases, end-to-side anastomosis in 2 cases, and composite heterologous pericardial patch in 2 cases. RCP with 40 mL/kg/min through the innominate artery during aortic arch reconstruction was employed for all pediatric patients. One single-dose histidine-ketoglutarate-tryptophan (HTK) solution was used for myocardial protection during CPB. Cardiopulmonary bypass time and aortic cross-clamp time were 165.6+/-32.4 min and 81.7+/-30.0 min, respectively. The mean regional cerebral perfusion time was 31.0+/-10.6 min; lowest nasopharyngeal temperature was 19.1+/-1.1 degrees C. Operative mortality rate in both groups was 8.3%. Mean follow-up was 10.5+/-4.8 months. There was no late mortality or postoperative neurologic, renal or hepatic complications. All patients are asymptomatic and are developing normally. One-stage total arch repair using the RCP technique is an excellent method that may minimize neurologic and renal complications. Our surgical strategy for arch anomaly has a low rate of residual and recurrent coarctation when performed in these infants.
Microcirculatory perfusion shift in the gut wall layers induced by extracorporeal circulation.
Kalder, Johannes; Ajah, Dieudonne; Keschenau, Paula; Kennes, Lieven N; Tolba, Rene; Kokozidou, Maria; Jacobs, Michael J; Koeppel, Thomas A
2015-02-01
Extracorporeal circulation (ECC) is regularly applied to maintain organ perfusion during major aortic and cardiovascular surgery. During thoracoabdominal aortic repair, ECC-driven selective visceral arterial perfusion (SVP) results in changed microcirculatory perfusion (shift from the muscularis toward the mucosal small intestinal layer) in conjunction with macrohemodynamic hypoperfusion. The underlying mechanism, however, is unclear. Therefore, the aim of this study was to assess in a porcine model whether ECC itself or the hypoperfusion induced by SVP is responsible for the mucosal/muscular shift in the small intestinal wall. A thoracoabdominal aortic approach was performed in 15 healthy pigs divided equally into three groups: group I, control; group II, thoracic aortic cross-clamping with distal aortic perfusion; and group III, thoracic aortic cross-clamping with distal aortic perfusion and SVP. Macrocirculatory and microcirculatory blood flow was assessed by transit time ultrasound volume flow measurement and fluorescent microspheres. In addition, markers for metabolism and intestinal ischemia-reperfusion injury were determined. ECC with a roller pump induced a significant switch from the muscularis and mucosal layer of the small intestine, even with adequate macrocirculation (mucosal/muscular perfusion ratio: group I vs II, P = .005; group I vs III, P = .0018). Furthermore, the oxygen extraction ratio increased significantly in groups II (>30%) and III (>40%) in the beginning of the ECC compared with the control (group I vs II, P = .0037; group I vs III, P = .0062). Lactate concentrations and pH values did not differ between groups I and II; but group III demonstrated a significant shifting toward a lactate-associated acidosis (lactate: group I vs III, P = .0031; pH: group I vs III, P = .0001). We demonstrated a significant shifting between the small intestinal gut wall layers induced by roller pump-driven ECC. The shift occurs independently of macrohemodynamics, with a significant effect on aerobic metabolism in the gut wall. Consequently, an optimal intestinal perfusion cannot be guaranteed by a roller pump; therefore, perfusion techniques need to be optimized. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Ischemic stroke risk reduction following cardiac surgery by carotid compression
NASA Astrophysics Data System (ADS)
Isingoma, Paul
Every year over 500,000 cardiovascular procedures requiring cardiopulmonary bypass (CPB) are performed in the United States. CPB is a technique that temporarily takes over the function of the heart and lungs during surgery, maintaining the circulation of blood and the oxygen content of the body. During CPB, an aortic cross-clamp is used to clamp the aorta and separate the systemic circulation from the outflow of the heart. Unfortunately, these procedures have been found to cause most cerebral emboli, which produce clinical, subclinical and silent neurologic injuries. Many clinical neurologic injuries occur in the postoperative period, with over 20% of the clinical strokes occurring during this period. In this study, we focus on visualizing the flow distribution in the aortic arch, the effect of carotid compression and the influence of compression time and MAP during CPB on reducing cerebral emboli. Experiments are performed with an aortic arch model in a mock cardiovascular system. Fluorescent particles are used to simulate emboli that are released into circulation immediately after carotid compression. The LVAD is used as the pump to produce flow in the system by gradually adjusting the speed to maintain desired clinical conditions. Aortic and proximal branches MAP of 65.0 +/- 5.0 mmHg (normal MAP) or 95.0 +/- 5.0 mmHg (high MAP), aortic flow of 4.0 +/- 0.5 L/min, and all branches flow (left and right carotids, and subclavian arteries) of 10% of the aortic flow. Flow distribution of particles is visualized using LaVision's DaVis imaging software and analyzed using imagej's particle analysis tool to track, count, and record particle properties from the aortic arch. Carotid compression for 10-20 seconds reduces the number of particles entering the carotid arteries by over 73% at normal MAP, and by over 85% at high MAP. A higher MAP resulted in fewer particles entering the branching vessels both at baseline and during occlusion conditions. A compression duration of 20s does not result in greater particle reduction than one of 10s. Our results demonstrate that brief compression of the common carotid arteries during an embolic shower can reduce the number of dangerous emboli by over 85%.
Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis
2017-05-01
Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.
Root replacement using stentless valves in the small aortic root: a propensity score analysis.
Kunihara, Takashi; Schmidt, Kathrin; Glombitza, Petra; Dzindzibadze, Vachtang; Lausberg, Henning; Schäfers, Hans-Joachim
2006-10-01
Root replacement using a stentless bioprosthesis may be the optimal approach to avoid patient-prosthesis mismatch in patients with a small aortic root. Primary root replacement, however, is considered to be associated with increased surgical risk. We compared early outcome of full root replacement with a stentless bioprosthesis with that of aortic valve replacement with a stented bioprosthesis using propensity score-matching analysis. Of 231 patients undergoing elective, first-time aortic valve replacement with a small root (< or = 22 mm), 120 patients were selected using propensity score-matching analysis. They underwent either root replacement using a 23-mm stentless bioprosthesis (stentless group, n = 60) or supra-annular aortic valve replacement using a 21-mm stented bioprosthesis (stented group, n = 60). Preoperative characteristics and frequency of concomitant operations were identical. Duration of operation (196 +/- 54 versus 174 +/- 49 minutes), cardiopulmonary bypass (112 +/- 36 versus 91 +/- 33 minutes), and aortic cross-clamping (76 +/- 21 versus 61 +/- 21 minutes) were significantly longer in the stentless group. However, the need for perioperative transfusion and the incidence of postoperative reexploration for bleeding (3% versus 8%) was lower, and ventilation time was shorter. Mean duration of intensive care and hospital stay were also significantly shorter (2.3 +/- 1.7 versus 4.0 +/- 3.9 days, 8.9 +/- 3.1 versus 12.4 +/- 5.7 days). In-hospital mortality was identical (5% each). No independent predictor for in-hospital mortality was identified. Full root replacement using a stentless bioprosthesis does not increase postoperative morbidity or mortality of aortic valve replacement and may be advantageous in patients with a small aortic root.
Leyla loop: a time-saving suture technique for robotic atrial closure
Kılıç, Leyla; Şenay, Şahin; Ümit Güllü, A.; Alhan, Cem
2013-01-01
The longer durations of cardiopulmonary bypass and aortic cross-clamp times remain the disadvantages of robotic or minimally invasive cardiac surgery. For this reason, every small contribution to speeding up these procedures is of the utmost importance. Here, we present a practical, easy and time-saving suture technique for atrial closure. It consists of a hand-made loop at one end of the suture and saves the time otherwise consumed by knotting. It may also be used during conventional or minimally invasive cardiac surgery. PMID:23760357
Moorjani, Narain; Modi, Amit; Mattam, Kavita; Barlow, Clifford; Tsang, Geoffrey; Haw, Marcus; Livesey, Steven; Ohri, Sunil
2010-05-01
The Biovalsalva aortic root prosthesis incorporates an Elan porcine stentless biological aortic valve suspended within a triple-layered vascular conduit with preformed aortic sinuses of Valsalva. This study compared implantation of the Biovalsalva prosthesis with a "handsewn" composite bioprosthetic graft (CE Perimount bovine bioprosthesis anastomosed to a gelatin-impregnated gelweave Dacron graft). Between December 2004 and January 2009, 39 patients underwent elective or urgent aortic root replacement (modified Bentall procedure with coronary button reimplantation) using a Biovalsalva (n = 21) or a handsewn bioprosthesis (n = 18) for aortic root dilatation. There was no significant difference in the preoperative variables between the two study groups including age (70.7 +/- 1.7 vs. 67.6 +/- 2.9 years, p > 0.05). There was no in-hospital mortality. Three patients in each group underwent concomitant aortic hemi-arch replacement. Patients who underwent Biovalsalva implantation had a reduced need for transfusion of blood (1.25 +/- 0.32 vs. 3.17 +/- 0.71 units, p < 0.05) and fresh frozen plasma (2.78 +/- 0.39 vs. 1.85 +/- 0.31, p < 0.05), and reduced mediastinal blood loss (416 +/- 52 vs. 583 +/- 74 mL, p < 0.05) compared to those with a handsewn bioprosthesis. Cardiopulmonary bypass time (141 +/- 6 vs. 170 +/- 17 minutes, p = NS) and aortic cross-clamp time (113 +/- 6 vs. 115 +/- 7 minutes, p = NS) were similar. Postoperative echocardiography demonstrated excellent hemodynamic function of the Biovalsalva prosthesis (mean size 25.1 +/- 0.4 mm valved conduit) with a peak pressure gradient of 26.2 +/- 1.9 mmHg and no or trivial valvular regurgitation. The Biovalsalva prosthesis should be considered for patients requiring a biological aortic root replacement. It offers an "off-the-shelf" preassembled composite biological valve conduit with excellent hemostatic and hemodynamic properties.
Debus, Eike S; Kölbel, Tilo; Duprée, Anna; Daum, Günter; Sandhu, Harleen K; Manzoni, Daniel; Wipper, Sabine H
2018-02-01
The hybrid SPIDER-graft consists of a proximal descending aortic stent graft and a conventional six branched Dacron graft for open abdominal aortic repair. Technical feasibility with regard to avoiding thoracotomy and extracorporeal circulation (ECC) during thoraco-abdominal aortic hybrid repair and peri-procedural safety of this novel device are unknown. This was a feasibility and safety study in domestic pigs (75-85 kg). The abdominal aorta including iliac bifurcation, left renal artery, and visceral arteries were exposed via retroperitoneal access. The right iliac branch was first temporarily anastomosed end to side to the distal aorta via partial clamping. During inflow reduction and infra-coeliac cross-clamping, the coeliac trunk (CT) was divided and the proximal stent graft portion of the SPIDER-graft was deployed into the descending aorta via the CT ostium. Retrograde visceral and antegrade aorto-iliac blood flow was maintained via the iliac side branch. The visceral, renal, and iliac arteries were sequentially anastomosed, finally replacing the first iliac end to side anastomosis. Technical success, blood flow, periods of ischaemia, and peri-procedural complications were evaluated after intra-operative completion angiography and post-operative computed tomography angiography. Six animals underwent successful thoracic stent graft deployment and distal open reconstruction without peri-operative death. The median thoracic graft implantation time was 4.5 min, and the median ischaemia times before reperfusion were 10 min for the CT, 8 min for the superior mesenteric artery, 13 min for the right renal artery, and 22 min for the left renal artery. Angiography demonstrated appropriate graft implantation and blood flow measurements confirmed sufficient blood flow through all side branches. In this translational pig model, thoraco-abdominal hybrid repair using the novel SPIDER-graft was successful in avoiding thoracotomy and ECC. Technical feasibility and safety appear promising, but need to be reassessed in humans. Copyright © 2017. Published by Elsevier Ltd.
Karim, Habib Md Reazaul; Yunus, Mohd; Saikia, Manuj Kumar; Kalita, Jyoti Prasad; Mandal, Mrinal
2017-01-01
Introduction: Cardiac surgery-associated kidney injury (CSA-AKI) is common but relatively less is known about its progression. The present study is aimed at evaluating the incidence and course of CSA-AKI and its relationship with the different durations of cardiopulmonary bypass (CPB) and cross clamp times. Materials and Methods: Occurrences of CSA-AKI are evaluated as per the Akin Kidney Injury Network (AKIN) criteria over the course of 5 postoperative day (POD) in 100 patients. The relationship of different durations of CPB and aortic cross clamp time with CSA-AKI is analyzed by Chi-squared test for trend and other appropriate tests using INSTAT software. Results: One hundred (43 male, 57 female; mean age of 37.01 ± 12.28 years, and baseline mean serum creatinine 0.99 ± 0.20 mg %) patients undergone mostly valve replacement, and congenital heart disease correction was evaluated. Nearly 49% suffered CSA-AKI (81.63% AKIN Class I) with maximum numbers on 2nd POD. Serum creatinine followed a falling trend 3rd POD onward except in 8.16% cases of CSA-AKI. Oliguria was absent even in AKIN Class II. The CPB time >70 min and cross clamp time >60 min increase CSA-AKI risk by an OR of 4.76 and 2.84, respectively (P < 0.05). Conclusion: CSA-AKI is very prevalent; mostly of AKIN Class I and increases with increasing CPB and cross clamp time. Urine output is not a reliable indicator of CSA-AKI. The AKIN Class II on the very 1st POD or increasing trend of serum creatinine beyond 3rd POD should alert for early intervention. PMID:28074790
Umakanthan, Ramanan; Petracek, Michael R; Leacche, Marzia; Solenkova, Nataliya V; Eagle, Susan S; Thompson, Annemarie; Ahmad, Rashid M; Greelish, James P; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Balaguer, Jorge M; Byrne, John G
2010-03-01
The study aim was to determine the safety and benefits of minimally invasive mitral valve surgery without aortic cross-clamping for mitral valve surgery after previous cardiac surgery. Between January 2006 and August 2008, a total of 90 consecutive patients (38 females, 52 males; mean age 66 +/- 9 years) underwent minimally invasive mitral valve surgery after having undergone previous cardiac surgery. Of these patients, 80 (89%) underwent mitral valve replacement and 10 (11%) mitral valve repair utilizing a small (5 cm) right lateral thoracotomy along the 4th or 5th intercostal space under fibrillatory arrest (mean temperature 28 +/- 2 degrees C). The predicted mortality, calculated using the Society of Thoracic Surgeons (STS) algorithm, was compared to the observed mortality. The mean ejection fraction was 45 +/- 13%, mean NYHA class 3 +/- 1, while 66 patients (73%) had previous coronary artery bypass grafting and 37 (41%) had previous valve surgery. Twenty-six patients (29%) underwent non-elective surgery. Cardiopulmonary bypass was instituted through axillary (n = 19), femoral (n = 70) or direct use aortic (n = 1) cannulation. Operative mortality was 2% (2/90), lower than the STS-predicted mortality of 7%. Three patients (3%) developed acute renal failure postoperatively, one patient (1%) required new-onset hemodialysis, and one (1%) developed postoperative stroke. No patients developed postoperative myocardial infarction. The mean postoperative packed red blood cell transfusion requirement at 48 h was 2 +/- 3 units. Minimally invasive right thoracotomy without aortic cross-clamping is an excellent alternative to conventional redo-sternotomy for reoperative mitral valve surgery. The present study confirmed that this technique is safe and effective in reducing operative mortality in high-risk patients undergoing reoperative cardiac surgery.
Simultaneous air transportation of the harvested heart and visceral organs for transplantation.
Aydin, U; Yazici, P; Kazimi, C; Bozoklar, A; Sozbilen, M; Zeytunlu, M; Kilic, M
2008-01-01
The purpose of this study was to evaluate the duration for organ procurement including both heart and visceral organs and outcomes of the simultaneous transportation of the teams back to the recipient hospitals. Between March 2005 and March 2007, 37/82 organ procurement was performed in the district hospitals and transported to our institution for organ transplantation. Combined heart and visceral organ procurement which was simultaneously transported to the recipient hospitals by one air vehicle was reviewed. After both the thoracic and abdominal cavities were entered, all intra-abdominal organs were mobilized allowing exposure of the inferior mesenteric vein and aorta. The supraceliac abdominal aorta was elevated. The attachments of the liver in the hilar region were incised and both kidneys and pancreas prepared for removal. After the inferior mesenteric vein and aorta were cannulated, simultaneous aortic cross-clamping was performed and cold preservation solution infused. Harvested organs were packed with ice and removed to the back table for initial preparation and packaging for air transport. The mean duration of 6 procurement procedures was 63 minutes (range 50-75 minutes) to aortic clamping, and 27.5 minutes (range, 20-40 minutes) between clamping and harvesting. Mean cold ischemia times for 6 hearts, 6 livers, 12 kidneys, 2 pancreas, and 1 small intestine were 2.4 hours (range, 2-3.5 hours), 5 hours (range, 3-8 hours), 10.3 hours (range, 8-15 hours), 6.7 hours, and 9.5 hours, respectively. No graft complication was observed to be associated with the procurement procedure. Better collaborations between surgical teams and rapid procurement techniques provide simultaneous air transportation back to the recipient hospital with reduced cold ischemia times of the visceral organs.
A Single Center Study of 1,179 Heart Transplant Patients-Factors Affecting Pacemaker Implantation.
Wellmann, Petra; Herrmann, Florian Ernst Martin; Hagl, Christian; Juchem, Gerd
2017-03-01
After around 10% of heart transplant patients require pacemaker implantation. The bradyarrhythmias causing pacemaker requirement include sinus node dysfunction (SND) and atrioventricular block (AVB). This study sought to define clinical predictors for pacemaker requirement as well as identify differences in the patient groups developing SND and AVB. Our operative database was used to collect retrospective recipient, donor, and operative data of all patients receiving orthotopic heart transplants between 1981 and 2016. In the 35-year period 1,179 transplants were performed (mean recipient age 45.5 ± 0.5 years, 20.4% female, 90.6% biatrial technique) with bradyarrhythmias requiring pacemaker implantation developing in 135 patients (11.5%). Independent risk factors were prolonged operative time 340 minutes versus 313 minutes (P = 0.027) and a biatrial anastomosis (P = 0.036). Ischemia time, cardiopulmonary bypass time, aortic cross clamp time, and reperfusion time all had no significant effect on pacemaker implantation rates. Similarly, whether the transplant was a reoperation, a retransplant, or performed after primary assist implantation had no effects on pacemaker implantation rates. There was no survival difference between the paced and nonpaced groups. The donor age was higher in the patients who developed AVB as the indication for pacemaker implantation (43 vs 34 years, P = 0.031). Patients with AVB had longer aortic cross clamp times and developed the arrhythmia later than those who developed SND. Use of the bicaval instead of the biatrial technique and shortened operative times should reduce pacemaker requirement after heart transplantation. Survival is not affected by this complication. © 2017 Wiley Periodicals, Inc.
Dement'eva, I I; Morozov, Iu A; Charnaia, M A
2013-01-01
125 patients after cardiac surgery operated on with the use of artificial blood circulation (ABC) were followed-up. Blood levels of cardiac protein, binding aliphatic acids and troponin 1 and 3 days after the operation were registered. The study showed that aorta clamping more then 90 minutes and hypothermic perfusion regimen influence cardiomyocites negatively. The state of "surgical trauma" and reperfusional myocardium damage was approximately the same during aortic surgery, myocardium revascularization with the use of aortic clamping and cardioplegia, and correction of the acquired heart disease, according to the dynamics of the studied proteins in blood. The minimal blood level of cardiac protein, binding aliphatic acids after coronary by-pass surgery on the working heart witnesses about negative influence of crystalloid hypothermic cardioplegia on coronary microcirculation.
Mihos, Christos G; Santana, Orlando; Pineda, Andres M; La Pietra, Angelo; Lamelas, Joseph
2014-01-01
We present our experience of concomitant right coronary artery bypass grafting (CABG) and aortic valve replacement performed via a right minithoracotomy in patients with coronary lesions not amenable to percutaneous intervention. A total of 17 patients underwent concomitant aortic valve replacement and right CABG between April 2008 and July 2013. A 5- to 6-cm minithoracotomy incision was made over the right second or third intercostal space, and the costochondral cartilage was transected. A saphenous vein bypass to the right coronary artery was then performed, initiating the anastomosis from the toe of the graft. Subsequently, the aortic valve was replaced using standard techniques. There were 6 men and 11 women. The median European System for Cardiac Operative Risk Evaluation II score mortality risk was 5% [interquartile range (IQR), 2%-8%]. The mean (SD) age was 77 (10) years, the left ventricular ejection fraction was 59% (8%), and the New York Heart Association functional class was 2.4 (0.8). One patient had a history of CABG. The mean (SD) cardiopulmonary bypass time was 168 (57) minutes, and the aortic cross-clamp time was 133 (36) minutes. Three patients underwent concomitant mitral valve surgery (replacement, 2; repair, 1). The median intensive care unit and hospital lengths of stay were 47 hours (IQR, 24-90) and 9 days (IQR, 5-13), respectively. There was one reoperation for bleeding, and there was one postoperative stroke. All patients were alive at a mean (SD) follow-up of 2 (1.1) years. Aortic valve replacement with concomitant CABG performed via a right minithoracotomy approach is feasible.
Bailey, Damian M; Evans, Tom G; Thomas, Kate Gower; White, Richard D; Twine, Chistopher P; Lewis, Michael H; Williams, Ian M
2016-08-01
What is the central question of this study? To what extent focal abdominal aortic aneurysmal (AAA) disease is associated with systemic remodelling of the vascular tree remains unknown. The present study examined whether anatomical differences exist between distances of the intervisceral artery origins and AAA location/size in patients with disease compared with healthy patients. What is the main finding and its importance? Intervisceral artery distances were shown to be consistently greater in AAA patients, highlighting the systemic nature of AAA disease that extends proximally to the abdominal aorta and its branches. The anatomical description of the natural variation in visceral artery origins has implications for the design of stent grafts and planning complex open aortic surgery. The initial histopathology of abdominal aortic aneurysmal (AAA) disease is atherosclerotic, later diverting towards a distinctive dilating rather than occlusive aortic phenotype. To what extent focal AAA disease is associated with systemic remodelling of the vascular tree remains unknown. The present study examined whether anatomical differences exist between the intervisceral artery origins and AAA location/size in patients with AAA disease (AAA+) relative to those without (AAA-). Preoperative contrast-enhanced computerized tomograms were reviewed in 90 consecutive AAA+ patients scheduled for open repair who underwent an infrarenal (n = 45), suprarenal (n = 26) or supracoeliac clamp (n = 19). These were compared with 39 age-matched AAA- control patients. Craniocaudal measurements were recorded from the distal origin of the coeliac artery to the superior mesenteric artery and from the origin of the superior mesenteric artery to both renal artery origins. Serial blood samples were obtained for estimation of the glomerular filtration rate before and after surgery. Intervisceral artery origins were shown to be consistently greater in AAA+ patients (P < 0.05 versus AAA-), although unrelated to AAA diameter (P > 0.05). Postoperative renal function became progressively more impaired the more proximal the clamp placement (estimated glomerular filtration rate for supracoeliac < suprarenal < infrarenal clamps, P < 0.05). These findings highlight the systemic nature of AAA disease that extends proximally to the abdominal aorta and its branches. The anatomical description of the natural variation in visceral artery origins has implications for the design of stent grafts and planning complex open aortic surgery. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.
[Late reoperations after repaired Stanford type A aortic dissection].
Huang, F H; Li, L P; Su, C H; Qin, W; Xu, M; Wang, L M; Jiang, Y S; Qiu, Z B; Xiao, L Q; Zhang, C; Shi, H W; Chen, X
2017-04-01
Objective: To summarize the experience of reoperations on patients who had late complications related to previous aortic surgery for Stanford type A dissection. Methods: From August 2008 to October 2016, 14 patients (10 male and 4 female patients) who underwent previous cardiac surgery for Stanford type A aortic dissection accepted reoperations on the late complications at Department of Thoracic and Cardiovascular Surgery, Nanjing Hospital Affiliated to Nanjing Medical University. The range of age was from 41 to 76 years, the mean age was (57±12) years. In these patients, first time operations were ascending aorta replacement procedure in 3 patients, ascending aorta combined with partial aortic arch replacement in 4 patients, aortic root replacement (Bentall) associated with Marfan syndrome in 3 patients, aortic valve combined with ascending aorta replacement (Wheat) in 1 patient, ascending aorta combined with Sun's procedure in 1 patient, Wheat combined with Sun's procedure in 1 patient, Bentall combined with Sun's procedure in 1 patient. The interval between two operations averaged 0.3 to 10.0 years with a mean of (4.8±3.1) years. The reasons for reoperations included part anastomotic split, aortic valve insufficiency, false aneurysm formation, enlargement of remant aortal and false cavity. The selection of reoperation included anastomotic repair, aortic valve replacement, total arch replacement and Sun's procedure. Results: Of the 14 patients, the cardiopulmonary bypass times were 107 to 409 minutes with a mean of (204±51) minutes, cross clamp times were 60 to 212 minutes with a mean of (108±35) minutes, selective cerebral perfusion times were 16 to 38 minutes with a mean of (21±11) minutes. All patients survived from the operation, one patient died from severe pulmonary infection 50 days after operation. Three patients had postoperative complications, including acute renal failure of 2 patients and pulmonary infection of 1 patient, and these patients were recovered after treatment. Thirteen patients were finally recovered from hospital. The patients were followed up for 16 to 45 months, and no aortic rupture, paraplegia and death were observed in the follow-up. Conclusions: Patients for residual aortic dissection after initial operations on Stanford type A aortic dissection should be attached great importance and always need emergency surgery, but the technique is demanding and risk is great for surgeons and patients, which need enough specification and accurate on aortic operation. More importantly, the Sun's procedure also should be performed on the treatment of residual aortic dissection or distal arch expansion, and obtains the short- and long-term results in the future.
Intraoperative colon mucosal oxygen saturation during aortic surgery.
Lee, Eugene S; Bass, Arie; Arko, Frank R; Heikkinen, Maarit; Harris, E John; Zarins, Christopher K; van der Starre, Pieter; Olcott, Cornelius
2006-11-01
Colonic ischemia after aortic reconstruction is a devastating complication with high mortality rates. This study evaluates whether Colon Mucosal Oxygen Saturation (CMOS) correlates with colon ischemia during aortic surgery. Aortic reconstruction was performed in 25 patients, using a spectrophotometer probe that was inserted in each patient's rectum before the surgical procedure. Continuous CMOS, buccal mucosal oxygen saturation, systemic mean arterial pressure, heart rate, pulse oximetry, and pivotal intra-operative events were collected. Endovascular aneurysm repair (EVAR) was performed in 20 and open repair in 5 patients with a mean age of 75 +/- 10 (+/-SE) years. CMOS reliably decreased in EVAR from a baseline of 56% +/- 8% to 26 +/- 17% (P < 0.0001) during infrarenal aortic balloon occlusion and femoral arterial sheath placement. CMOS similarly decreased during open repair from 56% +/- 9% to 15 +/- 19% (P < 0.0001) when the infrarenal aorta and iliac arteries were clamped. When aortic circulation was restored in both EVAR and open surgery, CMOS returned to baseline values 56.5 +/- 10% (P = 0.81). Mean recovery time in CMOS after an aortic intervention was 6.4 +/- 3.3 min. Simultaneous buccal mucosal oxygen saturation was stable (82% +/- 6%) during aortic manipulation but would fall significantly during active bleeding. There were no device related CMOS measurement complications. Intra-operative CMOS is a sensitive measure of colon ischemia where intraoperative events correlated well with changes in mucosal oxygen saturation. Transient changes demonstrate no problem. However, persistently low CMOS suggests colon ischemia, thus providing an opportunity to revascularize the inferior mesenteric artery or hypogastric arteries to prevent colon infarction.
Del Giglio, Mauro; Mikus, Elisa; Micari, Antonio; Calvi, Simone; Tripodi, Alberto; Campo, Gianluca; Maietti, Elisa; Castriota, Fausto; Cremonesi, Alberto
2018-01-01
Background Right anterior mini-thoracotomy (MIAVR) is a promising technique for aortic valve replacement. We aimed at comparing its outcomes with those obtained in a propensity-matched group of patients undergoing sternotomy at our two high-volume centers. Methods Main clinical and operative data of patients undergoing aortic valve replacement between January 2010 and May 2016 were retrospectively collected. A total of 678 patients were treated with a standard full sternotomy approach, while MIAVR was performed in 502. Propensity score matching identified 363 patients per each group. Results In-hospital mortality was not significantly different between the propensity-matched groups (1.7% in MIAVR patients vs. 2.2% in conventional sternotomy patients; P=0.79). No significant difference in the incidence of major post-operative complications was observed. Post-operative ventilation times (median 7, range 5–12 hours in MIAVR patients vs. median 7, range 5–12 in conventional sternotomy patients; P=0.72) were not significantly different between the two groups. Cardiopulmonary bypass time (61.0±21.0 vs. 65.9±24.7 min in conventional sternotomy group; P<0.01) and aortic cross-clamping time (48.3±16.7 vs. 53.2±19.6 min in full sternotomy group; P<0.01) were shorter in MIAVR group. EuroSCORE (OR 1.52, 95% CI, 1.12–2.06; P<0.01) was found to be the only independent predictor of intra-hospital mortality in the whole propensity-matched population. Conclusions Our experience shows that mini-access isolated aortic valve surgery is a reproducible, safe and effective procedure with similar outcomes and no longer operative times compared to conventional sternotomy. PMID:29707310
Rodrigues, Alfredo J; Evora, Paulo R B; Bassetto, Solange; Alves, Lafaiete; Scorzoni Filho, Adilson; Origuela, Eliana A; Vicente, Walter V A
2009-01-01
The aim of this prospective study was to compare the efficacy of intermittent antegrade blood cardioplegia with or without n-acetylcysteine (NAC) in reducing myocardial oxidative stress and coronary endothelial activation. Twenty patients undergoing elective isolated coronary artery bypass graft surgery were randomly assigned to receive intermittent antegrade blood cardioplegia (32 degrees C-34 degrees C) with (NAC group) or without (control group) 300 mg of NAC. For these 2 groups we compared clinical outcome, hemodynamic evolution, systemic plasmatic levels of troponin I, and plasma concentrations of malondialdehyde (MDA) and soluble vascular adhesion molecule 1 (sVCAM-1) from coronary sinus blood samples. Patient demographic characteristics and operative and postoperative data findings in both groups were similar. There was no hospital mortality. Comparing the plasma levels of MDA 10 min after the aortic cross-clamping and of sVCAM-1 30 min after the aortic cross-clamping period with the levels obtained before the aortic clamping period, we observed increases of both markers, but the increase was significant only in the control group (P= .039 and P= .064 for MDA; P= .004 and P= .064 for sVCAM-1). In both groups there was a significant increase of the systemic serum levels of troponin I compared with the levels observed before cardiopulmonary bypass (P< .001), but the differences between the groups were not significant (P= .570). Our investigation showed that NAC as an additive to blood cardioplegia in patients undergoing on-pump coronary artery bypass graft surgery may reduce oxidative stress and the resultant coronary endothelial activation.
[Clinical analysis of different root treatment methods in acute Stanford type A aortic dissection].
Xue, Y X; Zhou, Q; Pan, J; Wang, Q; Cao, H L; Fan, F D; Wang, D J
2017-04-01
Objective: To discuss the perioperative and follow-up results of different surgical methods for acute Stanford type A aortic dissection patients and analyzed the results. Methods: The clinic data of 351 acute Stanford type A aortic dissection patients received surgical therapy at Department of Thoracic and Cardiovascular Surgery, Nanjing University Medical School Affiliated Nanjing Drum Tower Hospital from January 2008 to December 2015 were analyzed retrospectively. There were 272 male and 79 female patients, aging from 22 to 83 years with a mean age of (52±13) years. According to root size, aortic valve structure and the status of dissection involvement, these patients were devided into three major groups: 218 cases with root reconstruction using Dacron felts, 34 cases with root reconstruction concomitant with aortic valve resuspension repair and 99 cases in with Bentall procedure. Proper shape based on the status of dissection involvement of Dacron patch was cut and put between the middle and outerlayer of aorta, then inside the inner layerone band Dacron felt was sutured with the aorta and the new middle layer with Dacron patch as mentioned above. In some cases the prolapsed aortic valve was re-suspended to the aortic cusp. Clinical outcomes among the 3 procedures were compared by χ(2) test, Fisher's exact test, t test and analysis of variance. Results: Cardiopulmonary bypass, cross-clamp, and circulatory arrest times of all the patients were (250±78), (171±70) and (31±10) minutes, respectively. The 30-day mortality was 9.2%(33/351), while no difference among the 3 procedures (9.6%, 8.8% and 9.1%). In the average follow-up time of (26.0±23.0) months (range from 0.5 to 90.0 months), survival rates were similar among the 3 procedures (77.7%, 77.4% and 77.8%). Only one patient received redo Bentall procedure because of severe aortic regurgitation and dilated aortic root (diameter of 50 mm). Conclusions: The indication of root management of acute Stanford type A aortic dissection is based on the diameter of aortic root, structure of aortic leaflets, and the dissection involvement. For most acute Stanford type A aortic dissection patients, aortic root reconstruction is a feasible and safe method.
Mini-invasive aortic surgery: personal experience.
Spinelli, Francesco; Stilo, Francesco; La Spada, Michele; Benedetto, Filippo; De Caridi, Giovanni; Barillà, David; Giardina, Massimiliano; David, Antonio
2014-01-01
In this study, we retrospectively evaluated our experience in minilaparotomy (MINI) and compared the results with conventional open repair (OPEN). From January 2005 to December 2012, we surgically treated 234 consecutive patients with elective infrarenal abdominal aortic aneurysms, 195 men and 39 women, with a mean age of 74 years. Inclusion criteria for MINI were not ruptured abdominal aortic aneurysm, increased surgical risk, anatomical limits for endovascular repair, no previous surgical invasion of the abdominal cavity, and no requirement for concomitant abdominal surgical invasion. Surgical treatment was OPEN in 113 patients (48.3%) and MINI through an 8- to 14-cm incision in 121 patients (51.7%). Epidural anesthesia has been added in 26.5% and in 19.3% of the MINI and OPEN patients, respectively. Mortality, complications, aortic clamping time, operative time, need for postoperative morphine therapy, time to solid diet, and length of hospital stay were registered. The MINI has been performed in all patients selected, with 72 aortoaortic grafts and 49 aortobisiliac grafts. Early mortality was 1.6% versus 3.5% (P > 0.5); 1-, 3-, and 5-year mortality were 7% versus 9%, 19% versus 22%, and 29% versus 34% (P > 0.5); complications were 12.2% versus 26.6% (P > 0.05); mean (SD) clamping time was 48 (12) versus 44 (14) minutes (P > 0.5); mean (SD) operative time was 218.72 (41.95) versus 191.44 (21.73) minutes (P > 0.025); mean (SD) estimated intraoperative blood loss was 425.64 (85.95) versus 385.30 (72.41) mL (P > 0.1); mean (SD) morphine consumption in the group given epidural and the group not given epidural was 0 (2) and 2 (2) mg intravenously (IV) versus 2 (4) (P < 0.5) and 4 (3) mg IV (P > 0.1); mean (SD) ambulation was 2.1 (0.6) versus 4.1 (2.7) (P < 0.5); mean (SD) time to solid diet was 2.1 (0.4) versus 3.5 (1.6) (P < 0.5); and mean (SD) length of hospital stay was 4.9 (1.64) versus 7.35 (1.95) days (P > 0.05), in the MINI and OPEN groups, respectively. Postoperative hernia at 3 years was 18% versus 23% in the MINI and OPEN groups (P < 0.5), respectively. The MINI gives the patients a significantly shorter period of recovery with the quality and safety of the OPEN. This experience suggested extending the indication to all surgical candidates without local limitations.
Mini-Bentall: An Interesting Approach for Selected Patients.
Mikus, Elisa; Micari, Antonio; Calvi, Simone; Salomone, Maria; Panzavolta, Marco; Paris, Marco; Del Giglio, Mauro
Minimally invasive surgery through an upper hemisternotomy for aortic valve replacement has become the routine approach with excellent results. Actually, the same minimally invasive access is used for complex ascending aorta procedures only in few centers. We report our experience with minimally invasive approach for aortic valve and ascending aorta replacement using Bentall technique. From January 2010 to November 2015, a total of 238 patients received ascending aorta and aortic valve replacement using Bentall De Bono procedure at our institution. Low- and intermediate-risk patients underwent elective surgery with a minimally invasive approach. The "J"-shaped partial upper sternotomy was performed through a 6-cm skin incision from the notch to the third right intercostal space. Patients who had previous cardiac surgery or affected by active endocarditis were excluded. The study included 53 patients, 44 male (83 %) with a median age of 63 years [interquartile range (IQR), 51-73 years]. A bicuspid aortic valve was diagnosed in 27 patients (51%). A biological Bentall using a pericardial Mitroflow or Crown bioprosthesis implanted in a Valsalva graft was performed in 49 patents. The remaining four patients were treated with a traditional mechanical conduit. Median cardiopulmonary bypass time and median cross-clamp time were respectively 84 (IQR, 75-103) minutes and 73 (IQR, 64-89) minutes. Hospital mortality was zero as well as 30-day mortality. Median intensive care unit and hospital stay were 1.9 and 8 days, respectively. The study population compared with patients treated with standard full sternotomy and similar preoperative characteristics showed similar results in terms of postoperative outcomes with a slightly superiority of minimally invasive group mainly regarding operative times, incidence of atrial fibrillation, and postoperative ventilation times. A partial upper sternotomy is considered a safe option for aortic valve replacement. Our experience confirms that a minimally invasive approach using a partial upper J-shaped sternotomy can be a safe alternative approach to the standard in selected patients presenting with complex aortic root pathology.
Pietropaoli, P; Caporelli, S; De Pace, F; Donati, A; Adrario, E; Luzi, A; Munch, C; Giovannini, C; Frezzotti, A R
1994-12-01
To verify the efficacy and absence of risk attributable to therapy with alkaline solutions for correction of lactic acidosis and to demonstrate the usefulness of L-carnitine in converting lactate into pyruvate in conditions of good blood oxygenation. Prospective study on a consecutive series of patients subdivided into three groups following the use of: alkalinizing therapy (group I), L-carnitine (group II), or saline solution (group III). Groups 1 and 2 were further subdivided into subgroups "a" and "b" according to the type of alkalinizing agent and of L-carnitine somministration. Teaching Hospital-Torrette di Ancona. 65 patients submitted to major vascular surgery with aortic clamping in the time period between January 1992 and August 1993. During aortic clamping patients of: group I received 2 mEq:kg of bicarbonate or tromentamolo according to the specific subgroup. Group II received a bolus of 2 g of L-carnitine, patients of group IIb received further 2 g of carnitine in continuous perfusion until the end of surgery. Group III received no pharmacological intervention. HR BP, arterial blood gases and lactic acid levels were measured at 12 pre-determined times. Only a neutralizing effect of alkalinizing therapy was observed, whereas the lactic acid measurements demonstrated no significant differences between the different groups. These results confirm the data of other Authors concerning the good compliance of alkalinizing therapy, however, there was demonstrated no clear evidence of its effective usefulness. No metabolic stimulation due to L-canitina could be demonstrated in our experimental conditions.
Nakajima, Masato; Tsuchiya, Koji; Fukuda, Shoji; Morimoto, Hironobu; Mitsumori, Yoshitaka; Kato, Kaori
2006-04-01
Aortic surgery for progressive aortic valve disease or aortic aneurysm after previous coronary artery bypass grafting (CABG) is a challenging procedure. We report the outcome of aortic reoperation after previous CABG and evaluate our management of patent grafts and our methods for obtaining myocardial protection. From February 2001 to July 2003, 6 patients with progressive aortic valve disease and aneurysm of the thoracic aorta were operated on. The group comprised 3 men and 3 women with a mean age of 67.6 years. There were 4 patients with an aneurysm of the aortic arch, 1 with chronic ascending aortic dissection, and 1 with progressive aortic valve stenosis. The interval between previous CABG and aortic surgery was 74.0 +/- 44.2 months. All reoperations were performed via median resternotomy. Myocardial protection was obtained by hypothermic perfusion of patent in-situ arterial grafts following cold-blood cardioplegia administration via the aortic root under aortic cross clamping. The operative procedure was aortic arch replacement in 4 patients, ascending aortic replacement with double CABG in 1, and aortic valve replacement in 1. All patients survived the reoperation. Postoperative maximum creatine kinase-MB was 49.2 +/- 29.8 and no new Q-waves occurred in the electrocardiogram nor were any new wall motion abnormalities recognized on echocardiography. There were no late deaths during a follow-up of 30.7 months. Reoperative aortic procedures after CABG can be performed safely with myocardial protection via hypothermic perfusion of a patent in-situ arterial graft.
Pottecher, Julien; Guillot, Max; Belaidi, Elise; Charles, Anne-Laure; Lejay, Anne; Gharib, Abdallah; Diemunsch, Pierre; Geny, Bernard
2013-04-01
By binding to cyclophilin D, cyclosporine A (CsA) inhibits mitochondrial permeability transition pore (mPTP) opening and prevents mitochondrial dysfunction and ultimately cell death after ischemia-reperfusion (IR) injury in cardiac muscle. This study tested whether CsA would decrease skeletal muscle oxidative stress and mitochondrial dysfunctions after aortic cross-clamping related IR. Forty-five Wistar rats were investigated. The sham group (n = 8) had aortic exposure but no ischemia, the IR group (n = 10) had aortic cross-clamping for 3 hours followed by 2 hours of reperfusion, and the IR+CsA group (n = 9) had two intraperitoneal injections of 10 mg of CsA at 90 and 150 minutes of ischemia before reperfusion. Mitochondrial coupling (acceptor control ratio) and mitochondrial respiratory chain complexes' activities were measured. Reactive oxygen species (ROS) production, cyclophilin D expression, and muscle inflammation were determined using dihydroethidium staining, Western blot, and immunohistochemistry, respectively. An additional 18 sham rats were investigated to determine CsA blood levels and the effects of CsA on mitochondrial respiration and calcium retention capacity, a marker of mPTP opening, both in myocardium and gastrocnemius with and without CsA. Compared with sham, IR decreased mitochondrial coupling (1.38 ± 0.06 vs 1.98 ± 0.20; P = .0092), increased ROS production (3992 ± 706 arbitrary units [AU] vs 1812 ± 322 AU; P = .033), was associated with macrophage infiltration, and decreased maximal oxidative capacity (V(max): 4.08 ± 0.38 μmol O(2)/min/g vs 5.98 ± 0.56 μmol O(2)/min/g; P = .015). Despite IR, CsA treatment totally restored mitochondrial coupling (1.93 ± 0.12; P = .023 vs IR), normalized ROS (1569 ± 348 AU; P = .0098 vs IR), and decreased inflammation. The V(max) was slightly enhanced (5.02 ± 0.39 μmol O(2)/min/g; P = .33 vs IR; P = .35 vs sham). Compared with myocardium, gastrocnemius muscle was characterized by a decreased cyclophilin D content (-50%) associated with an earlier opening of mPTP (calcium retention capacity increased from 10.85 ± 1.35 μM/mg dry weight [DW] to 12.11 ± 2.77 μM/mg DW; P = .65; and from 11.07 ± 1.67 to 37.65 ± 11.41 μM/mg DW; P = .0098 in gastrocnemius and heart, respectively). Cyclosporine A normalized ROS production, decreased inflammation, and restored mitochondrial coupling during aortic cross-clamping. Incomplete Vmax protection might be due to low cyclophilin D expression in gastrocnemius, preventing CsA from blocking mPTP opening. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Gasparovic, Hrvoje; Borojevic, Marko; Malojcic, Branko; Gasparovic, Kristina; Biocina, Bojan
2013-10-01
Aortic manipulation releases embolic material, thereby enhancing the probability of adverse neurologic outcomes following coronary artery bypass grafting (CABG). We prospectively evaluated 59 patients undergoing CABG. Patients in the single (SC, n = 37) and multiple clamp (MC, n = 22) groups were comparable in relation to age and operative risk (p > 0.05). Neurocognitive evaluation consisted of the Auditory Verbal Learning Test (AVLT), Color Trails Test A, the Grooved Pegboard test and the Mini-Mental State Examination. Data acquisition was performed preoperatively, early postoperatively and at the 4-month follow-up. Intraoperative transcranial Doppler (TCD) monitoring was used to quantify the embolic load in relation to different aortic clamping strategies. Preoperative neurocognitive results were similar between the groups (p > 0.05). The incidence of postoperative delirium was greater in the MC group but this failed to reach statistical significance (23% vs 8%, p = 0.14). SC patients had fewer embolization signals (270 ± 181 vs 465 ± 160, p < 0.0001). Early postoperative neurocognitive results were depressed in comparison to preoperative values in both groups (p < 0.05 for multiple comparisons). The magnitude of this cognitive depression was greater in the MC group (p < 0.05 for multiple comparisons). Preoperative levels of neurocognition were restored at follow-up in the SC group in all tests except the AVLT. A trend towards improvements in neurocognitive performances at follow-up was also observed in the MC group. Residual attention, motor skill and memory deficits were, however, documented with multiple tests. In conclusion, the embolic burden was significantly lower in the SC group. This TCD imaging outcome translated into fewer early cognition deficits and superior late restoration of function.
Brinkmann, Saskia J H; Buijs, Nikki; Vermeulen, Mechteld A R; Oosterink, Efraim; Schierbeek, Henk; Beishuizen, Albertus; de Vries, Jean-Paul P M; Wisselink, Willem; van Leeuwen, Paul A M
2016-09-01
Postoperative renal failure is a common complication after open repair of an abdominal aortic aneurysm. The amino acid arginine is formed in the kidneys from its precursor citrulline, and citrulline is formed from glutamine in the intestines. Arginine enhances the function of the immune and cardiovascular systems, which is important for recovery after surgery. We hypothesized that renal arginine production is diminished after ischemia-reperfusion injury caused by clamping of the aorta during open abdominal aortic surgery and that parenteral glutamine supplementation might compensate for this impaired arginine synthesis. This open-label clinical trial randomized patients who underwent clamping of the aorta during open abdominal aortic surgery to receive a perioperative supplement of intravenous alanyl-glutamine (0.5 g·kg(-1)·day(-1); group A, n = 5) or no supplement (group B, n = 5). One day after surgery, stable isotopes and tracer methods were used to analyze the metabolism and conversion of glutamine, citrulline, and arginine. Whole body plasma flux of glutamine, citrulline, and arginine was significantly higher in group A than in group B (glutamine: 391 ± 34 vs. 258 ± 19 μmol·kg(-1)·h(-1), citrulline: 5.7 ± 0.4 vs. 2.8 ± 0.4 μmol·kg(-1)·h(-1), and arginine: 50 ± 4 vs. 26 ± 2 μmol·kg(-1)·h(-1), P < 0.01), as was the synthesis of citrulline from glutamine (4.8 ± 0.7 vs. 1.6 ± 0.3 μmol·kg(-1)·h(-1)), citrulline from arginine (2.3 ± 0.3 vs. 0.96 ± 0.1 μmol·kg(-1)·h(-1)), and arginine from glutamine (7.7 ± 0.4 vs. 2.8 ± 0.2 μmol·kg(-1)·h(-1)), respectively (P < 0.001 for all). In conclusion, the production of citrulline and arginine is severely reduced after clamping during aortic surgery. This study shows that an intravenous supplement of glutamine increases the production of citrulline and arginine and compensates for the inhibitory effect of ischemia-reperfusion injury. Copyright © 2016 the American Physiological Society.
Resection of subvalvular aortic stenosis. Surgical and perioperative management in seven dogs.
Komtebedde, J; Ilkiw, J E; Follette, D M; Breznock, E M; Tobias, A H
1993-01-01
Open heart surgery was performed during cardiopulmonary bypass (CPB) to surgically correct subvalvular aortic stenosis in seven dogs. After initiation of total CPB, cardiac arrest was induced by antegrade and retrograde administration of blood cardioplegia. The subvalvular fibrous stenosis was resected through a transverse aortotomy. Intraoperatively and postoperatively, dobutamine, nitroprusside, lidocaine, blood(-products), and crystalloid solutions were used to manage hypotension and optimize cardiac index. Aortic cross-clamp time varied from 73 to 166 minutes, and duration of CPB varied from 130 to 210 minutes. Iatrogenic incision into the mitral valve in two dogs was the most significant intraoperative complication. Postoperative complications included: hypoproteinemia (n = 7), premature ventricular depolarization (n = 6), increased systemic vascular resistance index (n = 5), increased O2 extraction (n = 3), pulmonary edema (n = 2), and decreased cardiac index (n = 1). All seven dogs were discharged alive and in stable condition. Six dogs are alive and in stable condition after a mean follow up of 15.8 months. This is the first detailed report of CPB in a series of clinical veterinary patients. Using the techniques described in this paper, open heart surgery of considerable duration can be performed successfully in dogs with significant myocardial hypertrophy and endomyocardial fibrosis secondary to subvalvular aortic stenosis.
Takagi, Hisato; Umemoto, Takuya
2016-01-01
To assess the safety and efficacy, we performed a meta-analysis of total arch replacement with frozen elephant trunk in exclusive acute type A (neither chronic nor type B) aortic dissection. Databases including MEDLINE and EMBASE were searched through March 2015 using Web-based search engines (PubMed and OVID). Eligible studies were case series of frozen elephant trunk enrolling patients with acute type A (neither chronic nor type B) aortic dissection reporting at least early (in-hospital or 30-day) all-cause mortality. Study-specific estimates were combined in both fixed- and random-effect models. Fifteen studies enrolling 1279 patients were identified and included. Pooled analyses demonstrated the cardiopulmonary bypass time of 207.1 (95% confidence interval [CI], 186.1-228.1) minutes, aortic cross-clamp time of 123.3 (95% CI, 113.1-133.5) minutes, selective antegrade cerebral perfusion time of 49.3 (95% CI, 37.6-61.0) minutes, hypothermic circulatory arrest time of 39.0 (95% CI, 30.7-47.2) minutes, early mortality of 9.2% (95% CI, 7.7-11.0%), stroke of 4.8% (95% CI, 2.5-9.0%), spinal cord injury of 3.5% (95% CI, 1.9-6.6%), mid- to long-term (≥1-year) overall mortality of 13.0% (95% CI, 10.4-16.0%), reintervention of 9.6% (95% CI, 5.6-15.8%), and false lumen thrombosis of 96.8% (95% CI, 90.7-98.9%). Total arch replacement with frozen elephant trunk provides a safe alternative to that with conventional elephant trunk in patients with acute type A aortic dissection, with acceptable early mortality and morbidity. The rates of mid- to long-term reintervention and false lumen non-thrombosis may be lower in patients undergoing the frozen than conventional elephant trunk procedure. © The Author(s) 2016.
Single-centre experience with the frozen elephant trunk technique in 251 patients over 15 years.
Shrestha, Malakh; Martens, Andreas; Kaufeld, Tim; Beckmann, Erik; Bertele, Sebastian; Krueger, Heike; Neuser, Julia; Fleissner, Felix; Ius, Fabio; Abd Alhadi, Firas; Hanke, Jasmin; Schmitto, Jan D; Cebotari, Serghei; Karck, Matthias; Haverich, Axel; Chavan, Ajay
2017-11-01
Our goal was to present our 15-year experience (2001-2015) with the frozen elephant trunk (FET) technique. A total of 251 patients (82 with aortic aneurysms, 96 with acute aortic dissection type A, 4 with acute type B dissections, 52 with chronic aortic dissection type A, 17 with chronic type B dissection and 67 redo cases) underwent FET implantation with either the custom-made Chavan-Haverich (n = 66), the Jotec E-vita (n = 31) or the Vascutek Thoraflex hybrid (n = 154) prosthesis. The cases were assigned to an early period (2001-2011) and a contemporary period (2012-present). Mean cardiopulmonary bypass time, aortic cross-clamp time, circulatory arrest time and selective antegrade cerebral perfusion time were 241 ± 72, 125 ± 59, 56 ± 30 and 81 ± 34 min, respectively. Incidence of rethoracotomy for bleeding, stroke, spinal cord injury, prolonged ventilatory support (>96 h) and long-term dialysis were 18, 14, 2, 24 and 2%, respectively. The in-hospital mortality rate was 11% (in acute aortic dissection type A, 12%). Of the 2 patients with graft infections, 1 died and the other had a protracted hospital stay. There were 49 second-stage procedures in the downstream aorta: either open surgical [n = 25 (thoraco-abdominal, n = 15; descending, n = 6; infrarenal, n = 4)] or transfemoral endovascular (n = 23). Elective thoracic endovascular aneurysm repair R implantation was successful in all 23 cases. FET results are comparable with those of the published results of the conventional elephant trunk technique. FET is an ideal landing zone for subsequent transfemoral endovascular completion. Patients with graft infections may have dismal results. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Kokot, Michał; Biolik, Grzegorz; Ziaja, Damian; Fojt, Tadeusz; Kędzierski, Leszek; Antoniak, Katarzyna; Janowska, Mirosława; Pawlicki, Krzysztof; Ziaja, Krzysztof; Duława, Jan
2014-01-01
One of the most severe complications of repair surgery for abdominal aortic aneurysms (AAA) is acute kidney injury (AKI). Even small rises in serum creatinine are associated with increased mortality. The aim of this study was to assess the dynamics of AKI after elective AAA surgery using novel markers. The study group consisted of 22 patients with AAA. We measured urinary liver- (u-L-FABP) and heart-type fatty acid-binding proteins (u-H-FABP) before, during and within 3 days after surgery. We found an abrupt and significant elevation of both urine FABPs normalized to urinary creatinine; u-L-FABP reached its peak value 2 hours after aortic clamp release {137.79 (38.57-451.79) vs. 9.94 (6.82-12.42) ng/mg baseline value, p<0.05; values are medians (lower-upper quartile)}. The peak value of u-H-FABP was reported 72 hours after aortic clamp release {16.462 (4.182-37.595) vs. 0.141 (0.014-0.927) ng/mg baseline value, p<0.05}. The serum creatinine level did not changed significantly during the investigation period. The significant rise of both u-L-FABP and u-H-FABP after AAA surgery indicates renal proximal and distal tubule injury in this population. Our results suggest that, after AAA surgery, the distal tubules could be more affected than the proximal ones. u-FABPs could serve as sensitive biomarkers of kidney tubular injury and may allow to detect the very early phases of AKI.
Dilatation of aortic grafts over time: what to expect and when to be concerned.
Schroeder, Torben V; Eldrup, Nikolaj; Just, Sven; Hansen, Marc; Nyhuus, Bo; Sillesen, Henrik
2009-06-01
Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent with knitted polyester grafts compared with ePTFE. Dilatation occurs within the first year after implantation and can be, in part, explained by a discrepancy between the initial nominal graft diameter and its diameter after clamp release, probably due to an in vivo adaptation of the textile structure. Interestingly, graft dilatation did not appear to be associated with an increased frequency of graft-related complications.
Weltz, Adam S; Harris, Donald G; O'Neill, Natalie A; O'Meara, Lindsay B; Brenner, Megan L; Diaz, Jose J
2015-01-01
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a technique that has been shown to provide central vascular control to support proximal aortic pressure and minimize hemorrhage in a wide variety of clinic settings, however the role of REBOA for emergency general surgery is less defined. This is a report of a 44 year old man who experienced hemorrhagic shock during video-assisted retroperitoneal debridement (VARD) for necrotizing pancreatitis where REBOA was used to prevent ongoing hemorrhage and death. This is the first documented report REBOA being used during pancreatic debridement in the literature and one of the first times it has been used in emergency general surgery. The use of REBOA is an option for those in hemorrhagic shock whom conventional aortic cross-clamping or supra-celiac aortic exposure is either not possible or exceedingly dangerous. REBOA allows for adequate resuscitation and can be used as a bridge to definitive therapy in a range of surgical subspecialties with minimal morbidity and complications. The risks associated with insertion of wires, sheaths, and catheters into the arterial system, as well as the risk of visceral and spinal cord ischemia due to aortic occlusion mandate that the use of this technique be utilized in only appropriate clinical scenarios. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Load dependence of left ventricular contraction and relaxation. Effects of caffeine.
Leite-Moreira, A F; Correia-Pinto, J; Gillebert, T C
1999-08-01
Load dependence of left ventricular (LV) contraction and relaxation was investigated at baseline and after alteration of intracellular calcium handling by caffeine. Afterload was increased by aortic clamp occlusions (n = 281) in anesthetized open-chest dogs (n = 7). Control and first heartbeat after the intervention were considered for analysis. Caffeine (50 mg/kg, iv) had no inotropic effect. The systolic LV pressure (LVP), developed in response to aortic occlusion, decreased as ejection proceeded and this pressure generating capacity was not affected by caffeine. Late-systolic aortic occlusions induced premature onset and accelerated rate of initial LVP fall at baseline and similarly after caffeine. Graded diastolic aortic occlusions induced systolic LVP elevations of various magnitudes. Smaller LVP elevations prolonged ejection and accelerated LVP fall, while larger elevations had opposite effects. The transition from acceleration to deceleration was observed at 83.1 +/- 1.1% of peak isovolumetric LVP at baseline and at lower loads, at 77.6 +/- 1.2%, after caffeine (p < 0.01). Isovolumetric heartbeats prolonged the time constant tau by 238 +/- 70% at baseline and only by 155 +/- 44% after caffeine (p < 0.01). The relaxation-systolic pressure relation, which describes afterload dependence of relaxation, was also modified by caffeine. Caffeine affected LV relaxation without altering contractility. As a consequence contraction-relaxation coupling was modified by caffeine. These results might help to understand load dependence of relaxation in conditions where intracellular calcium handling is altered.
Risk factors of neurological complications in cardiac surgery.
Baranowska, Katarzyna; Juszczyk, Grzegorz; Dmitruk, Iwona; Knapp, Małgorzata; Tycińska, Agnieszka; Jakubów, Piotr; Adamczuk, Anna; Stankiewicz, Adrian; Hirnle, Tomasz
2012-01-01
Postoperative complications are integral to cardiac surgery. The most serious ones are stroke, which develops in about 7.5% of the patients, and postoperative encephalopathy, which affects 10-30% of the patients. According to bibliographical data, the number of complications is increasing. To analyse the risk factors and the types of neurological complications in patients undergoing heart surgery. We assessed retrospectively 323 consecutive patients undergoing surgery at the Department of Cardiac Surgery, University Teaching Hospital, Medical University of Bialystok, Poland, between July 2007 and June 2008. Group 1 comprised patients without neurological complications (n = 287; 89%) and Group 2 consisted of patients with neurological complications (n = 36; 11%). Our analysis included the following: preoperative status (age, sex, co-morbidities), intraoperative course (surgery type, duration of cardiopulmonary bypass [CPB], duration of aortic cross-clamping, types of medications administered, necessity of reinfusion from the cardiotomy reservoir and the necessity of tranexamic acid infusion) and the postoperative course (time to regaining consciousness, duration of mechanical ventilation, development of complications, types of complications). The results were then analysed statistically: arithmetic means and standard deviations were calculated for quantitative variables and the quantitative and percentage distributions were calculated for qualitative variables. The between- group comparisons of the quantitative variables were carried out using the t-Student test, while the qualitative variables were compared using the χ(2) test. The variables that proved significant in the univariate comparisons were included in the multivariate model. Regression analysis was the final step of the analysis of the risk factors for neurological complications. Based on the analysis of the ROC curve we calculated the cutoff values for the continuous variables. We calculated odds ratios with their 95% confidence intervals. P values of less than 0.05 were considered statistically significant. Among the 36 patients in Group 2, postoperative encephalopathy developed in 22 patients, transient ischaemic attacks in 7 patients, ischaemic stroke in 6 patients (associated with right hemisphere damage in 3 patients and with left hemisphere damage in 3 patients) and haemorrhagic stroke in 1 patient (right hemisphere). Early mortality was 5% with 2 (0.69%) patients dying in Group 1 and 14 (38.9%) in Group 2. Univariate analysis revealed that the preoperative risk factors of neurological complications were: age >68 years (with a cutoff value of 58.5 years), a history of stroke with paresis, atrial fibrillation (AF) and a euroSCORE of >6 (with a cutoff value of 4.5). The peri- and postoperative risk factors included: surgery type (complex coronary and valvular surgeries aortic valve surgeries), duration of CPB of >142 min, duration of aortic crossclamping of >88 min, mean perfusion pressure during CPB of <70 mm Hg, haemodilution manifested by a haematocrit (HCT) of <28%, perfusate supply, time to regaining consciousness of >14.5 h and duration of artificial ventilation of >30.5 h. Multivariate analysis revealed the following factors to increase the risk of neurological complications: long duration of ventilation, a history of stroke with paresis, AF, low HCT values and long duration of aortic cross-clamping. The Nagelkerke R2 coefficient of determination was 0.636, the sensitivity was 74.36%, the specificity was 97.545% and the accuracy was 94.74%. In patients undergoing heart surgery, the independent risk factors of neurological complications in the first 30 days include: long duration of ventilation, a history of stroke with paresis, AF, haemodilution manifested by an HCT of <28% and long duration of aortic cross-clamping. Neurological complications are associated with high postoperative mortality.
Zhang, Dongze; Liu, Jinxu; Zheng, Hong; Tu, Huiyin; Muelleman, Robert L.; Li, Yu-Long
2016-01-01
Impairment of arterial baroreflex sensitivity is associated with mortality in patients with chronic heart failure (CHF). Elevation of plasma angiotension II (Ang II) contributes to arterial baroreflex dysfunction in CHF. A reduced number of voltage-gated sodium (Nav) channels in aortic baroreceptor neurons are involved in CHF-blunted arterial baroreflex. In this study, we investigated acute effect of Ang II on Nav currents in the aortic baroreceptor neuron and on arterial baroreflex in sham and coronary artery ligation-induced CHF rats. Using Ang II 125I radioimmunoassay, real-time RT-PCR and western blot, we found that Ang II levels, and mRNA and protein expression of angiotension II type 1 receptor (AT1R) in nodose ganglia (NG) from CHF rats were higher than that from sham rats. Local microinjection of Ang II (0.2 nmol) into the NG decreased the arterial baroreflex sensitivity in sham rats, whereas losartan (1 nmol, an AT1R antagonist) improved the arterial baroreflex sensitivity in CHF rats. Data from patch-clamp recording showed that Ang II (100 nM) acutely inhibited Nav currents in the aortic baroreceptor neurons from sham and CHF rats. In particular, inhibitory effect of Ang II on Nav currents in the aortic baroreceptor neurons was larger in CHF rats than that in sham rats. Losartan (1 μM) totally abolished the inhibitory effect of Ang II on Nav currents in sham and CHF aortic baroreceptor neurons. These results suggest that elevation of endogenous Ang II in the NG contributes to impairment of the arterial baroreflex function in CHF rats through inhibiting Nav channels. PMID:25827427
Immediate Outcomes of Aortic Valve Replacement with Sutureless versus Stentless Bioprosthesis.
Ihsan Parlar, Ali; Onur Hanedan, Muhammet; Mataraci, Ilker; Ali Yuruk, Mehmet; Sayar, Ufuk; Kemal Arslan, Ali; Ozer, Tanil
2016-01-01
Aortic valve replacement (AVR) with a sutureless valve is an innovative therapy in high-risk elderly patients. The study aim was to compare the early results of AVR using sutureless aortic valves or stentless aortic bioprostheses. A retrospective analysis was conducted of 55 patients who underwent AVR with either a sutureless valve (Perceval S; n = 24 or Edwards Intuity; n = 9) or a stentless valve (Sorin Freedom SOLO™; n = 22). Baseline patient characteristics were similar in both groups, except for NYHA class. Concomitant procedures were performed in 17 patients (51.5%) of the sutureless group and in nine patients (40.9%) of the stentless group (p = 0.44). The aortic cross-clamp time was 55 ± 23 min in the sutureless group and 102 ± 36 min in the stentless group (p <0.0001), while the postoperative peak aortic gradient was 19.5 ± 5.0 mmHg and 29.3 ± 15.4 mmHg for the sutureless group and stentless group, respectively (p = 0.037). The postoperative mean gradient was 9.3 ± 3.4 mmHg for the sutureless group and 15.1 ± 10.5 mmHg for the stentless group (p = 0.06). Blood product transfusion was required less frequently by the sutureless group, but drainage and bleeding was similar in both groups. The intensive care unit and hospital stays were significantly shorter in favor of the sutureless group. One sutureless patient (3.0%) and two stentless patients (9.1%) died in hospital (p = 0.557). Early results of the present study suggested that surgical AVR with a sutureless valve is associated with a good hemodynamic performance and an improved early outcome.
Aorta-Iliac Bypass in Thoracoabdominal Aortic Aneurysm Repair in Young Chinese Patients.
Duan, Yu-Yin; Ge, Yi-Peng; Zheng, Jun; Pan, Xu-Dong; Dong, Xiu-Hua; Ma, Wei-Guo; Cheng, Li-Jian; Zhu, Jun-Ming; Liu, Yong-Min; Sun, Li-Zhong
2016-04-01
Many surgical methods of thoracoabdominal aortic aneurysm repair (TAAAR) have been introduced over the past several decades, with varying degrees of success. We developed an aorta-iliac bypass technique to treat thoracoabdominal aortic aneurysm (TAAA) in young Chinese patients. The aim of this study is to evaluate the results of this technique intraoperatively and postoperatively. From June 2014 to March 2015, 28 patients underwent TAAAR using aorta-iliac bypass technique. A four-branched tetrafurcate graft was used. Two branches of the graft are sutured to bilateral common iliac arteries in an end-to-side fashion. The trunk of the graft was sutured to the proximal descending aorta in an end-to-end fashion. Then aorta-iliac bypass was established, and the lower extremities, viscera organ and spinal cord (SC) obtained perfusion from proximal descending aorta via the bypass graft. The thoracic and abdominal aorta were clamped in a staged fashion. The patent segmental arteries (SAs), and visceral arteries (coeliac trunk, superior mesenteric arteries, and renal arteries) were reattached sequentially. Evoked potential (EP) monitoring was adopted to assess the SC ischaemia throughout the procedure. The postoperative outcomes and follow-up results of this technique were evaluated. There was no in-hospital mortality. Complications included acute kidney dysfunction and pulmonary haemorrhage in one case (3.6%) each. The SAs were reattached in all cases. The EP wave disappeared after proximal descending aorta was clamped, and gradually recovered after the patent SAs reattached. The median follow-up after operation was eight months (range, 1-10 months). There was no delayed neurologic deficit or late death. Thoracoabdominal aortic aneurysm repair using aorta-iliac bypass may be a simple and safe choice for young Chinese patients with thoracoabdominal aortic aneurysms. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Poon, Shi Sum; Theologou, Thomas; Harrington, Deborah; Kuduvalli, Manoj; Oo, Aung
2016-01-01
Background Despite recent advances in aortic surgery, acute type A aortic dissection remains a surgical emergency associated with high mortality and morbidity. Appropriate management is crucial to achieve satisfactory outcomes but the optimal surgical approach is controversial. The present systematic review and meta-analysis sought to access cumulative data from comparative studies between hemiarch and total aortic arch replacement in patients with acute type A aortic dissection. Methods A systematic review of the literature using six databases. Eligible studies include comparative studies on hemiarch versus total arch replacement reporting short, medium and long term outcomes. A meta-analysis was performed on eligible studies reporting outcome of interest to quantify the effects of hemiarch replacement on mortality and morbidity risk compared to total arch replacement. Result Fourteen retrospective studies met the inclusion criteria and 2,221 patients were included in the final analysis. Pooled analysis showed that hemiarch replacement was associated with a lower risk of post-operative renal dialysis [risk ratio (RR) =0.72; 95% confidence interval (CI): 0.56–0.94; P=0.02; I2=0%]. There was no significant difference in terms of in-hospital mortality between the two groups (RR =0.84; 95% CI: 0.65–1.09; P=0.20; I2=0%). Cardiopulmonary bypass, aortic cross clamp and circulatory arrest times were significantly longer in total arch replacement. During follow up, no significant difference was reported from current studies between the two operative approaches in terms of aortic re-intervention and freedom from aortic reoperation. Conclusions Within the context of publication bias by high volume aortic centres and non-randomized data sets, there was no difference in mortality outcomes between the two groups. This analysis serves to demonstrate that for those centers doing sufficient total aortic arch activity to allow for publication, excellent and equivalent outcomes are achievable. Conclusions on differences in longer term outcome data are required. We do not, however, advocate total arch as a primary approach by all centers and surgeons irrespective of patient characteristics, but rather, a tailored approach based on surgeon and center experience and patient presentation. PMID:27386403
Hrelec, M; Klicek, R; Brcic, L; Brcic, I; Cvjetko, I; Seiwerth, S; Sikiric, P
2009-12-01
We focused on abdominal aorta, clamped and transected bellow renal arteries, and aortic termino-terminal anastomosis created in Albino male rats. We suggested stomach cytoprotection theory holding endothelium protection and peptidergic anti-ulcer cytoprotection therapy to improve management of abdominal aorta anastomosis and thrombus formation. The stable gastric pentadecapeptide BPC 157 (GEPPPGKPADDAGLV, MW 1419) is a small anti-ulcer peptide efficient in inflammatory bowel disease trials (PL 14736) and various wound treatment, no toxicity reported. After 24 h following aortic termino-terminal anastomosis, we shown that BPC 157 (10 microg/kg) may also decrease formation of cloth after aortic termino-terminal anastomosis and preserved walking ability and muscle strength when given as a bath immediately after aortic anastomosis creation. This may be important since aortic termino-terminal anastomosis is normally presenting in rats with a formed cloth obstructing more than third of aortic lumen, severely impaired walking ability, painful screaming and weak muscle strength. Thereby, the effect of BPC 157 (10 microg/kg) was additionally studied at 24 h following aortic termino-terminal anastomosis. Given at the that point, intraperitoneally, within 3 minutes post-application interval the pentadecapeptide BPC 157 rapidly recovered the function of lower limbs and muscle strength while no cloth could be seen in those rats at the anastomosis site.
Hayatsu, Yukihiro; Kawamoto, Shunsuke; Matsunaga, Tadao; Haga, Yoichi; Saiki, Yoshikatsu
2014-10-01
The aim of our study was to develop a novel monitoring system for spinal cord blood flow (SCBF) to test the efficacy of the SCBF sensor in an animal model. The sensor system consisted of 2 optical fibers, a pedestal for fiber fixation, and a mirror for the laser reflection and was incorporated into a cerebrospinal fluid drainage catheter. In vivo studies were performed in a swine model (n=10) to measure SCBF during spinal cord ischemia induced by clamping the descending thoracic aorta and supra-aortic neck vessels, when necessary. A temporary low cardiac output model was also created by inflow clamping of the inferior vena cava to analyze the quantitative changes in SCBF during this maneuver. The developed SCBF monitoring catheter placed intrathecally could detect SCBF in all the swine. The SCBF after aortic crossclamping at the fourth intercostal level exhibited diverse changes reproducibly among the swine, with a >25% reduction in SCBF in 5 pigs, an increase in 3, and no significant changes in 2. Consistent reductions were recorded during inferior vena cava occlusion. The mean SCBF decreased by 32% after inferior vena cava occlusion when the cardiac output had decreased by 27%. We have developed a novel SCBF sensor that could detect real-time changes in spinal cord perfusion in a swine model. The device holds promise to detect imminent ischemia or ensure acceptable blood perfusion in the spinal cord and could further enhance our understanding of spinal cord circulation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Urinary and proximal tubule acidification during reduction of renal blood flow in the rat.
Jaramillo-Juárez, F; Aires, M M; Malnic, G
1990-01-01
1. The effects of reduction in renal blood flow (RBF) on urinary acidification and proximal tubule H+ ion secretion were studied after partial aortic clamping in rats. 2. Acute reduction of the renal perfusion pressure (from 109 +/- 3.88 to 77.4 +/- 1.05 mmHg) decreased both inulin and PAH (p-aminohippurate) clearances to about one-third of their control values. Absolute levels of urinary sodium excretion also decreased markedly, but fractional sodium excretion did not change significantly. 3. Urine pH and bicarbonate levels were not affected, but titratable acidity increased significantly from 0.12 +/- 0.011 to 0.25 +/- 0.042 muequiv min-1 ml-1 glomerular filtration rate (GFR). During aortic clamping, cortical PCO2 as determined by means of Severinghaus microelectrodes was reduced by a mean value of 7.0 +/- 1.5 mmHg. 4. Proximal tubule acidification kinetics were studied by stationary microperfusion techniques in which the time course of pH changes was monitored by pH microelectrodes. Steady-state pH fell from a mean control value of 6.77 +/- 0.03 to 6.65 +/- 0.02, and stationary bicarbonate concentrations from 4.70 +/- 0.27 to 2.84 +/- 0.18 mM. Acidification half-time decreased from 5.07 +/- 0.30 to 4.39 +/- 0.19 s, and net bicarbonate reabsorption increased from 1.63 +/- 0.14 to 1.99 +/- 0.12 nmol cm-2 s-1, these changes being statistically significant. 5. The experiments demonstrate that both overall acid excretion and proximal acid secretion are not compromised by a large decrease of RBF to about one-third of the control value; titratable acid excretion and proximal net bicarbonate reabsorption were even moderately increased under these conditions. PMID:2348400
de Vaal, M H; Gee, M W; Stock, U A; Wall, W A
2016-12-01
Because aortic occlusion is arguably one of the most dangerous aortic manipulation maneuvers during cardiac surgery in terms of perioperative ischemic neurological injury, the purpose of this investigation is to assess the structural mechanical impact resulting from the use of existing and newly proposed occluders. Existing (clinically used) occluders considered include different cross-clamps (CCs) and endo-aortic balloon occlusion (EABO). A novel occluder is also introduced, namely, constrained EABO (CEABO), which consists of applying a constrainer externally around the aorta when performing EABO. Computational solid mechanics are employed to investigate each occluder according to a comprehensive list of functional requirements. The potential of a state of occlusion is also considered for the first time. Three different constrainer designs are evaluated for CEABO. Although the CCs were responsible for the highest strains, largest deformation, and most inefficient increase of the occlusion potential, it remains the most stable, simplest, and cheapest occluder. The different CC hinge geometries resulted in poorer performance of CC used for minimally invasive procedures than conventional ones. CEABO with a profiled constrainer successfully addresses the EABO shortcomings of safety, stability, and positioning accuracy, while maintaining its complexities of operation (disadvantage) and yielding additional functionalities (advantage). Moreover, CEABO is able to achieve the previously unattainable potential to provide a clinically determinable state of occlusion. CEABO offers an attractive alternative to the shortcomings of existing occluders, with its design rooted in achieving the highest patient safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Retrograde and antegrade cerebral perfusion: results in short elective arch reconstructive times.
Milewski, Rita Karianna; Pacini, Davide; Moser, G William; Moeller, Patrick; Cowie, Doreen; Szeto, Wilson Y; Woo, Y Joseph; Desai, Nimesh; Di Marco, Luca; Pochettino, Alberto; Di Bartolomeo, Roberto; Bavaria, Joseph E
2010-05-01
Debate remains regarding optimal cerebral circulatory management during relatively noncomplex, short arch reconstructive times. Both retrograde cerebral perfusion with deep hypothermic circulatory arrest (RCP/DHCA) and antegrade cerebral perfusion with moderate hypothermic circulatory arrest (ACP/MHCA) have emerged as established techniques. The aim of the study was to evaluate perioperative outcomes between antegrade and retrograde cerebral perfusion techniques for elective arch reconstruction times less than 45 minutes. Between 1997 and September 2008, 776 cases from two institutions were reviewed to compare RCP/DHCA and ACP/MHCA perfusion techniques. At the University of Pennsylvania, 682 were treated utilizing RCP/DHCA cerebral protection. At the University of Bologna, 94 were treated with ACP/MHCA and bilateral cerebral perfusion. Mean cerebral ischemic time and visceral ischemic time differed between RCP/DHCA and ACP/MHCA (p < 0.001). Multivariate analysis showed age more than 65 years, atherosclerotic aneurysm, and cross-clamp time as predictors of the composite endpoint of mortality, neurologic event, and acute myocardial infarction. There was no significant difference in permanent neurologic deficit, temporary neurologic dysfunction, or renal failure, between RCP/DHCA and ACP/MHCA. Mortality was comparable across both techniques. Both RCP/DHCA and ACP/MHCA have emerged as effective techniques for selected aortic arch operations with low morbidity and mortality. Univariate analysis revealed no statistically significant differences in primary or secondary outcomes between techniques for aortic reconstruction times less than 45 minutes. Data from this study demonstrate that selective use of either RCP/DHCA or ACP/MHCA provides excellent cerebral and visceral outcomes for elective open aortic surgery with short arch reconstructive times. Copyright (c) 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Outcomes of Solo Smart valve in a single-center experience of 270 patients.
Liu, Hao; Khani-Hanjani, Abbas; Yang, Siyuan; Wang, Wei; Sidhu, Surita; Mullen, John; Modry, Dennis; Wang, Shaohua
2018-04-03
The Solo Smart pericardial aortic valve has been widely used in Europe as an option for aortic valve replacement (AVR). We are reporting early and midterm clinical outcomes of AVR with the Solo Smart valve in a single North America center. This is a retrospective study of 270 consecutive patients who had AVR at Mazankowski Alberta Heart Institute from February 2011 to March 2015. Follow-up and echocardiographic data were collected retrospectively from electronic and paper charts. Univariate and multivariate analysis were performed to evaluate the results. The mean age was 71.2±10.0 years, 67.4% were male, and 79.3% had combined procedures. Mean STS Score was 4.18±3.91. Early mortality was 3.7% for the entire group and 0% for isolated aortic valve replacement group. Mean cross-clamp time for isolated AVR and AVR with concomitant procedure was 70.8±12.7min and 117.0±45.0min, respectively. Permanent pacemaker implantation was necessary in 2.2% of patients. Echocardiography demonstrated a reduction in mean gradients from 40.8±17.4mmHg to 7.6±3.7 mmHg and peak gradient from 72.5 ± 48.8 mmHg to 15.5±7.5 mmHg. The 1-, 3-, and 5- year overall survival was 93.0%, 86.5% and 75.9%, respectively. At 5 years, freedom from valve-related death was 92.4%, freedom from structural valve deterioration and freedom from aortic valve reoperation were 96.4% and 98%, respectively. The Solo Smart valve is safe and has excellent hemodynamic performance. Aortic valve reoperation and rates of valve-related adverse events during midterm follow-up were low.
Dumas, Ryan P; Chreiman, Kristen M; Seamon, Mark J; Cannon, Jeremy W; Reilly, Patrick M; Christie, Jason D; Holena, Daniel N
2018-05-23
Emergency department thoracotomy (EDT) must be rapid and well-executed. Currently there are no defined benchmarks for EDT procedural milestones. We hypothesized that trauma video review (TVR) can be used to define the 'normative EDT' and generate procedural benchmarks. As a secondary aim, we hypothesized that data collected by TVR would have less missingness and bias than data collected by review of the Electronic Medical Record (EMR). We used continuously recording video to review all EDTs performed at our centre during the study period. Using skin incision as start time, we defined four procedural milestones for EDT: 1. Decompression of the right chest (tube thoracostomy, finger thoracostomy, or clamshell thoracotomy with transverse sternotomy performed in conjunction with left anterolateral thoracotomy) 2. Retractor deployment 3. Pericardiotomy 4. Aortic Cross-clamp. EDTs with any milestone time ≥ 75 th percentile of time or during which a milestone was omitted were identified as outliers. We compared rates of missingness in data collected by TVR and EMR using McNemar's test. 44 EDTs were included from the study period. Patients had a median age of 30 [IQR 25-44] and were predominantly African-American (95%) males (93%) with penetrating trauma (95%). From skin incision, median times in minutes to milestones were as follows: right chest decompression: 2.11 [IQR 0.68-2.83], retractor deployment 1.35 [IQR 0.96-1.85], pericardiotomy 2.35 [IQR 1.85-3.75], aortic cross-clamp 3.71 [IQR 2.83-5.77]. In total, 28/44 (64%) of EDTs were either high outliers for one or more benchmarks or had milestones that were omitted. For all milestones, rates of missingness for TVR data were lower than EMR data (p < 0.001). Video review can be used to define normative times for the procedural milestones of EDT. Steps exceeding the 75 th percentile of time were common, with over half of EDTs having at least one milestone as an outlier. Data quality is higher using TVR compared to EMR collection. Future work should seek to determine if minimizing procedural technical outliers improves patient outcomes. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hemodynamics on abrupt stoppage of centrifugal pumps during left ventricular assist.
Kono, S; Nishimura, K; Nishina, T; Akamatsu, T; Komeda, M
2000-01-01
A magnetically suspended centrifugal pump (MSCP), developed for long-term ventricular assist, is reliable and durable because it has no shaft or seal. However, with nonvalve pumps such as a MSCP, regurgitation occurs when they accidentally stop without cannula clamping. We investigated the hemodynamics during temporary stoppage of a MSCP being used as a left ventricular assist system (LVAS), comparing two inflow cannulation sites. In four sheep (weight, 35-45 kg), microspheres were injected into the left main coronary artery to induce heart failure. An outflow cannula was sutured onto the descending aorta, and two inflow cannulae were inserted into the left atrium and the left ventricle. The MSCP was stopped with both the left ventricular cannula and left atrial cannula clamped, and the hemodynamics and P-V loops were recorded. Each cannula was then unclamped in order, and similar parameters were recorded. LVEDP increased at unclamping of the left ventricular cannula (ULVC), and rose further at unclamping of the left atrial cannula (ULAC). Aortic pressure did not change at ULVC, but decreased at ULAC. The effective systemic flow that subtracted the regurgitant flow through the MSCP from left ventricular output was half at ULVC and almost 0 at ULAC. When stopping centrifugal pumps without circuit clamping, hemodynamic deterioration is less at ULVC than at ULAC. This finding suggests that left ventricular inflow cannulation is recommended to allow more time in emergency situations.
Aortic valve replacement with the Biocor PSB stentless xenograft.
Bertolini, P; Luciani, G B; Vecchi, B; Pugliese, P; Mazzucco, A
1998-08-01
The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and quality of life satisfactory.
Long-term follow-up of stentless prosthesis.
Sansone, Fabrizio; Dato, Guglielmo Mario Actis; Zingarelli, Edoardo; Ferrero, Emanuele; Prot, Sara; Ceresa, Fabrizio; Patanè, Francesco; Casabona, Riccardo
2014-05-01
Stentless prostheses have an interesting hemodynamic performance when compared to stented prostheses and are recommended in cases of small aortic annulus. From January 1996 to January 2004, 138 patients suffering from aortic disease, underwent aortic valve replacement. • Group A: 93 patients underwent stentless aortic valve implantation [stentless Biocor (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil) and stentless Sorin (Sorin Group, Saluggia, Italy)]. • Group B: 45 patients underwent stented aortic valve implantation (stented Biocor). Patients were assessed by clinical evaluation and echocardiography after a mean follow up of 124.5 ± 58.2 months. There was a significant difference in terms of time of extracorporeal circulation and aortic cross clamp. The actuarial survival at 4, 8, 12, and 15 years is 77%, 50%, 21%, and 18%, respectively. Freedom from reoperation at 4, 8, 12, and 14 years was 92%, 83%, 73%, and 63%, respectively. Freedom from all events, death, and reoperation at 4, 8, 12, and 14 years was 70%, 39%, 13%, and 8%, respectively. There is no statistical difference among the two groups in terms of actuarial survival, freedom from reoperation, and freedom from re-hospitalization for prosthesis-related causes. There was a significantly higher incidence of pacemaker implantation in Group A and the causes are not known. The rate of freedom from reoperation is high in both groups for the patients who remained alive. There was no statistical difference about prosthesis dysfunction between the two groups. The higher incidence of death in Group A cannot be explained by causes related to the prosthesis because there is no difference in terms of causes of death. Rates of reoperation did not differ between the two groups. The results obtained with stentless prostheses are encouraging even in long-term follow-up. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista
2011-11-01
Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates <2.0 kg). A cardioplegia delivery system was inserted into the aortic root. Under moderate hypothermia, ascending and descending aorta were cross-clamped, and "beating heart and brain" aortic arch repair was performed. Arch repair was composed of patch augmentation in five, end-to-side anastomosis in three, and replacement in two patients. Average cardiopulmonary bypass time was 163 ± 68 min (71-310). In two patients only (one HLHS, one complex single ventricle), a period of cardiac arrest was required to complete intracardiac repair. In such cases, antegrade blood cardioplegia was delivered directly via the same catheter used for selective myocardial perfusion. Average time of splanchnic ischemia during cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight <3.0 kg, needed delayed sternal closure. No neurologic dysfunction was noted. Renal function proved satisfactory in all, while liver function was adequate in all but one. The present experience suggests that selective and independent cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Brain natriuretic peptide in cardiac surgery--influence of aprotinin.
Bail, Dorothee H L; Ziemer, Gerhard
2009-08-14
This study was designed to examine plasma concentrations of BNP and its correlations to the perioperative course in patients' cardiopulmonary bypass (CPB). Sixty-five patients with coronary artery disease (CAD) undergoing CPB were examined. Pre, intra and postoperative BNP values and hemodynamic parameters were measured. The BNP peak correlated neither with any hemodynamic parameters, with the duration of aortic cross-clamping (AXCL), of the operation or with CBP-time, nor with the use of catecholamines. BNP values were significantly higher with the perioperative use of aprotinin. These results confirm that the metabolism and biological activity of BNP may differ following CPB. An additional reason for increased postoperative BNP values might be the use of aprotinin.
Cho, Ah-Reum; Kwon, Jae-Young; Kim, Choongrak; Hong, Jung-Min; Kang, Christine
2017-04-01
Near-infrared spectroscopy sensors often cannot be attached at the commercially recommended locations because combined use of neurological monitoring systems is common during on-pump cardiac surgery. The primary purpose of this study was to compare the incidence of regional cerebral oxygen desaturation and regional cerebral oxygen saturation values detected using near-infrared spectroscopy between the upper and lower forehead during on-pump cardiac surgery. A prospective observational study was conducted with 25 adult patients scheduled for elective on-pump cardiac surgery. Regional cerebral oxygen saturations at the left upper and lower forehead and other clinical measurements were monitored intraoperatively. McNemar's test was used to analyze differences in the incidence of cerebral regional oxygen desaturation between the left upper and lower forehead. Two-way repeated measures ANOVA with post hoc Bonferroni correction was used to compare the regional cerebral oxygen saturation at each time point. There was a significantly higher incidence of regional cerebral oxygen desaturation at the upper than lower forehead only at 1 h after initiation of aortic cross-clamping. There were significant differences between the left upper and lower regional cerebral oxygen saturation values throughout the observation period. Regional cerebral oxygen saturation was significantly lower at the upper than lower forehead during on-pump cardiac surgery. However, disagreements in detection of cerebral regional oxygen desaturation were only significant at 1 h after initiation of aortic cross-clamping. WHO-ICTRP, Clinical Research Information Service (CRiS). ID: KCT0000971. URL: https://cris.nih.go.kr/cris/search/search_result_st01_en.jsp?seq=3678&type=my .
Tang, Y F; Han, L; Lu, F L; Song, Z G; Lang, X L; Zou, L J; Xu, Z Y
2016-07-01
To summarize the results and methods of left subclavian artery revascularization by stented trunk fenestration for acute Stanford type A aortic dissection. Clinical data of 67 patients (54 male and 13 female, mean age of (50±10) years) underwent surgical treatment of left subclavian artery fenestration for acute Stanford A aortic dissection in Department of Cardiothoracic Surgery, Changhai Hospital, Second Military Medical College between September 2008 and December 2014 were analyzed retrospectively. The origin of the left subclavian artery was in the true lumen and no dissection existed near the artery's starting. There were 18 cases of Marfan's syndrome. Preoperative echocardiography showed moderate to severe aortic regurgitation in 10 cases, and mitral regurgitation in 3 cases. Electrocardiogram showed myocardial ischemia in 5 cases. Three patients had acute impaired renal function. All the patients received total arch replacement combined with stented elephant trunk implantation. Left subclavian artery revascularization was performed by stented trunk fenestration as follows: firstly, stented elephant trunk was implanted to completely cover the left subclavian artery, then part of stented trunk's polyester lining was removed which is located at the origin of left subclavian artery. Aortic root procedures included aortic valve replacement in 2 cases, Bentall procedure in 21 cases and aortic valve sparing in 44 cases. Three patients received mitral valve repair and 6 patients received coronary artery bypass grafting. The cardiopulmonary bypass time, cross-clamp time, and circulatory arrest time were (179±32) minutes, (112±25) minutes, and (26±10) minutes, respectively. The in-hospital mortality was 7.5% (5/67): 2 patients died of multiple organ failure, 1 patient died of acute renal failure and another 2 patients died of severe infection shock. Two patients required reexploration for root bleeding. Transient neurology dysfunction developed in 6 patients. Six patients received tracheotomy and prolonged ventilation due to pulmonary infection. All patients discharged from the hospital were followed up for 1 to 5 years. During long-term follow-up, the survival rate was 100% and 89.8% at 1 and 5 years, respectively. CT angiography was performed once per year after discharged. The left subclavian artery perfusion was good. No dissection or anastomosis leakage was identified in any case. Stroke and left limb ischemia did not develope. For acute Stanford type A aortic dissection whose origin of the left subclavian artery is in the true lumen and no dissection existed near the artery's starting, the left subclavian artery revascularization by stented trunk fenestration technique during total arch replacement combined with stented elephant trunk implantation is reliable and effective.
Comparison of del Nido Cardioplegia With Blood Cardioplegia in Adult Combined Surgery.
Hamad, Raphael; Nguyen, Anthony; Laliberté, Éric; Bouchard, Denis; Lamarche, Yoan; El-Hamamsy, Ismail; Demers, Philippe
del Nido solution (DNS) is a single-dose cardioplegia designed for pediatric use proposed to offer superior myocardial protection in adults. However, few data support this claim. We hypothesized that DNS and modified blood cardioplegia solution (BS) provide equivalent safety in combined adult valve surgery. Between November 2014 and December 2015, 25 patients underwent primary aortic valve replacement and concomitant coronary artery bypass grafting (CABG) with DNS. Outcomes were compared with 25 patients who underwent the same surgery with BS between September 2013 and August 2015. All preoperative characteristics, comorbidities, and number of CABG performed were similar between groups. One hospital death occurred in the BS group. Postoperative creatine kinase, MB isotype (16.7 ± 5.3 μg/L vs. 22.1 ± 8.9 μg/L, P = 0.011) and troponin T levels (260 ± 105.3 ng/L vs. 370.5 ± 218.4 ng/L, P = 0.028) were significantly lower in the DNS group. There was no difference in inotropic or vasoactive agent use (P = 0.512). Cardiopulmonary bypass times (65.5 ± 12.5 min vs. 76.6 ± 19.1 min, P = 0.019) and cross-clamp times (55.6 ± 11.2 min vs. 64.3 ± 18.9 min, P = 0.05) were lower in the DNS group but total operating room times (P = 0.198) were similar. Peak postoperative creatinine levels were similar in both groups (P = 0.063). There was no difference in postoperative outcomes including acute renal failure (P > 0.999), atrial fibrillation (P = 0.773), acute respiratory failure (P > 0.999), nor stroke or transient ischemic attack (P > 0.999). Intensive care unit stay (P = 0.213) and hospital stay (P = 0.1) did not differ between groups. The DNS can be used as an alternative to BS in adult concomitant aortic valve replacement + CABG surgery. This supports our hypothesis that in this specific setting, DNS provides comparable myocardial protection as BS, with possibly shorter cardiopulmonary bypass and cross-clamp times.
Minimally invasive mitral valve surgery expands the surgical options for high-risks patients.
Petracek, Michael R; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Balaguer, Jorge M; Byrne, John G
2011-10-01
A simplified minimally invasive mitral valve surgery (MIMVS) approach avoiding cross-clamping and cardioplegic myocardial arrest using a small (5 cm) right antero-lateral incision was developed. We hypothesized that, in high-risk patients and in patients with prior sternotomy, this approach would yield superior results compared to those predicted by the Society of Thoracic Surgeons (STS) algorithm for standard median sternotomy mitral valve surgery. Five hundred and four consecutive patients (249 males/255 females), median age 65 years (range 20-92 years) underwent MIMVS between 1/06 and 8/09. Median preoperative New York Heart Association function class was 3 (range 1-4). Eighty-two (16%) patients had an ejection fraction ≤35%. Forty-seven (9%) had a STS predicted mortality ≥10%. Under cold fibrillatory arrest (median temperature 28°C) without aortic cross-clamp, mitral valve repair (224/504, 44%) or replacement (280/504, 56%) was performed. Thirty-day mortality for the entire cohort was 2.2% (11/504). In patients with a STS predicted mortality ≥ 10% (range 10%-67%), the observed 30-day mortality was 4% (2/47), lower than the mean STS predicted mortality of 20%. Morbidity in this high-risk group was equally low: 1 of 47 (2%) patients underwent reexploration for bleeding, 1 of 47 (2%) patients suffered a permanent neurologic deficit, none had wound infection. The median length of stay was 8 days (range 1-68 days). This study demonstrates that MIMVS without aortic cross-clamp is reproducible with low mortality and morbidity rates. This approach expands the surgical options for high-risk patients and yields to superior results than the conventional median sternotomy approach.
Importance of designated thoracic trauma surgeons in the management of traumatic aortic transection.
Albrink, M H; Rodriguez, E; England, G J; McKeown, P P; Hurst, J M; Rosemurgy, A S
1994-04-01
The medical literature is replete with reports on traumatic aortic transection. These reports have delineated many factors regarding the morbidity and high mortality of this ominous injury. Most reports are reviews of the collective experience of a single institution over a period of years. It is likely that many authors writing on the subject of traumatic aortic transection have no experience with operative repair of the lesion. There has been debate about the various techniques of primary repair versus graft insertion, as well as the question of whether cardiopulmonary bypass is superior to the "clamp and sew" methods. No studies have directly examined the skills of individual surgeons with respect to outcome. We present the results of a study from a university-affiliated level I trauma center in which the outcomes from various groups of surgeons were compared over a 5-year period. The information in this study strongly suggests that designated thoracic trauma surgeons who are promptly available and have dedicated interests in trauma patients achieve better results.
Outcome after surgery for acute aortic dissection type A in the elderly: a single-center experience.
Berndt, Rouven; Haneya, Assad; Jussli-Melchers, Jill; Tautorat, Insa; Schmidt, Kirstin; Rahimi, Aziz; Cremer, Jochen; Schoeneich, Felix
2015-03-01
Despite improvements in surgical and perfusion techniques, surgery for acute aortic dissection type A (AADA) remains associated with high mortality rates. The aim of this study was to evaluate outcome after surgery for AADA in elderly in comparison with the outcome in younger patients. Between January 2004 and December 2012, 204 patients underwent operation for AADA. Of these, 65 patients were aged 70 years and older (elderly group; range, 70-85 years) and 139 were younger than 70 years (younger group; range, 18-69 years). No significant differences were detected between the groups with regard to preoperative risk factors on admission. Significantly more number of elderly patients than younger underwent supracoronary replacement of the ascending aorta (93.8% versus 80.6%, p = 0.013). In comparison to the elderly patients, younger patients more frequently received complex surgery (Bentall and David operation). The mean extracorporeal circulation time (183 ± 62 minutes versus 158 ± 3 minutes; p = 0.003) and the mean aortic cross-clamp time (100 ± 45 minute versus 82 ± 30 minute; p = 0.006) were significantly higher for younger patients. No significant differences in postoperative complications and major morbidity were observed. The operative mortality (elderly group 4.6% versus younger group 1.4%; p = 0.33) and 30-day mortality (elderly group 18.5% versus younger group 8.6%; p = 0.06) were without statistical significance between the groups. Surgery for AADA in the elderly resulted in acceptable mortality. Satisfactory outcomes should encourage the offering of surgery in these patients. Georg Thieme Verlag KG Stuttgart · New York.
Grocott, Hilary P; Ambrose, Emma; Moon, Mike
2016-10-01
Selective antegrade cerebral perfusion (SACP) involving cannulation of either the axillary or innominate artery is a commonly used technique for maintaining cerebral blood flow (CBF) during the use of hypothermic cardiac arrest (HCA) for operations on the aortic arch. Nevertheless, asymmetrical CBF with hypoperfusion of the left cerebral hemisphere is a common occurrence during SACP. The purpose of this report is to describe an adjunctive maneuver to improve left hemispheric CBF during SACP by applying extrinsic compression to the left carotid artery. A 77-yr-old male patient with a history of aortic valve replacement presented for emergent surgical repair of an acute type A aortic dissection of a previously known ascending aortic aneurysm. His intraoperative course included cannulation of the right axillary artery, which was used as the aortic inflow during cardiopulmonary bypass and also allowed for subsequent SACP during HCA. After the onset of HCA, the innominate artery was clamped at its origin to allow for SACP. Shortly thereafter, however, the left-sided cerebral oxygen saturation (SrO2) began to decrease. Augmenting the PaO2, PaCO2 and both SACP pressure and flow failed to increase left hemispheric SrO2. Following the use of ultrasound guidance to confirm the absence of atherosclerotic disease in the carotid artery, external pressure was applied partially compressing the artery. With the carotid compression, the left cerebral saturation abruptly increased, suggesting pressurization of the left cerebral hemispheric circulation and augmentation of CBF. Direct ultrasound visualization and cautious partial compression of the left carotid artery may address asymmetrical CBF that occurs with SACP during HCA for aortic arch surgery. This strategy may lead to improved symmetry of CBF and corresponding cerebral oximetry measurements during aortic arch surgery.
Wong, Randolph H L; Baghai, Max; Yu, Simon C H; Underwood, Malcolm J
2013-05-01
Aneurismal dilatation of the remaining thoracic aorta after ascending aortic interposition grafting for type 'A' aortic dissection is not uncommon. For such complex cases, one treatment option is total arch replacement and elephant trunk procedure with the Sienna(TM) collared graft (Vascutek, Inchinnan, UK) technique followed by a staged thoracic endovascular aortic repair (TEVAR). The video illustrates our technique in a 56-year-old man with an extensive aortic arch and descending thoracic aortic dissecting aneurysm. For the 'open' procedure femoral arterial and venous cannulation was used along with systemic cooling and circulatory arrest at 22 °C. Upon circulatory arrest, the aortic arch was incised and antegrade cerebral perfusion achieved via selective cannulation to the right brachiocephalic and left common carotid artery, keeping flow rates at 10-15 mL/kg/min and perfusion pressure at 50-60 mmHg. Arch replacement with an elephant trunk component was then performed and after completion of the distal aortic anastomosis antegrade perfusion via a side-arm in the graft was started and the operation completed using a variation of the 'sequential' clamping technique to maximize cerebral perfusion. The second endovascular stage was performed two weeks after discharge. Two covered stents were landing from the elephant trunk to the distal descending thoracic aorta, to secure the distal landing a bare stent of was placed to cover the aorta just distal to the origin of the celiac axis. The left subclavian artery was embolised with fibre coils. Post TEVAR angiogram showed no endoleak Although re-operative total arch replacement and elephant trunk procedure and subsequent TEVAR remained a challenging procedure, we believe excellent surgical outcome can be achieved with carefully planned operative strategy.
Lumbar muscle rhabdomyolysis after abdominal aortic surgery.
Bertrand, M; Godet, G; Fléron, M H; Bernard, M A; Orcel, P; Riou, B; Kieffer, E; Coriat, P
1997-07-01
Lumbar muscle rhabdomyolysis has been very rarely reported after surgery. The aim of this study was to determine its incidence and main characteristics in a large population undergoing abdominal aortic surgery. Over a 21-mo period, 224 consecutive patients, 209 male and 15 female, mean age 65 +/- 10 yr, underwent abdominal aortic surgery (aortic aneurysm in 142 patients and occlusive aortic degenerative disease in 82 patients). Surgical incision was a midline incision with exaggerated hyperlordosis in 173 patients and a flank incision with a retroperitoneal approach in 51 patients. Postoperative rhabdomyolysis was diagnosed in 20 patients. In these patients, 9 (4%) experienced severe low back pain, and lumbar muscle rhabdomyolysis was confirmed by tomodensitometry (n = 6) or muscle biopsy (n = 3). The remaining 11 patients had lower limb muscle rhabdomyolysis. Rhabdomyolysis occurred after surgery of longer duration, which involved more frequent visceral artery reimplantation, with longer duration of aortic clamping and greater intraoperative bleeding. Lumbar rhabdomyolysis occurred in younger patients who were more frequently obese. On first postoperative day, the mean creatine kinase (CK) value was greater in lumbar rhabdomyolysis than in lower limb rhabdomyolysis (17,082 +/- 15,003 vs 3,313 +/- 3,120 IU/L, P < 0.05). Acute renal failure and postoperative death did not occur in patients with lumbar muscle rhabdomyolysis. Lumbar rhabdomyolysis was not a rare event after abdominal aortic surgery (4%). This syndrome was characterized by postoperative low back pain of unusual severity, which required analgesic therapy, and induced a very high increase in CK with typical findings at tomodensitometry or muscle biopsy but was not associated with postoperative renal failure.
Papadimitriou, Dimitrios; Mayer, Dieter; Lachat, Mario; Pecoraro, Felice; Frauenfelder, Thomas; Pfammatter, Thomas; Ueda, Hideki; Donas, Konstantinos; Veith, Frank J; Rancic, Zoran
2012-10-01
Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004-2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were prolonged extra-anatomically with surgical grafts to reach the femoral bifurcation. In the following five cases, a tapered tubular stent graft was deployed through the aortic wall, landing inside a bifurcated surgical graft that was extra-anatomically connected to the iliac or femoral arteries. In the last case, which presented a hostile abdomen and high-risk for extensive surgery, a similar technique was used, but on the iliac artery level. In that case, an iliac stent graft re-loaded 'upside down' was deployed through the left common iliac wall, landing distally inside a hand-made 10 × 10 mm bifurcated surgical graft that was extra-anatomically connected to the left external iliac artery and to the right femoral artery. The distal anastomoses on the seven cases were performed either with running sutures (ten) or with VORTEC (four). Telescoping aortic and/or iliac anastomosis was successful in all patients. There was no perioperative mortality. One patient developed postoperative hyperperfusion of the left leg and necessitated fasciotomy. During a mean follow-up of 1.8 ± 2 years (minimum: 270 days, maximum: 7.1 years), all of the grafts remained patent and there was neither stent-graft migration nor stenosis on the level of the aortic or iliofemoral connection. One patient showed disease progression and required percutaneous transluminal angioplasty on the external iliac artery during follow-up. The uneventful perioperative course in these seven patients, with a follow-up of up to six years, underscores that this new technique can be considered in patients with aortoiliac or aortofemoral occlusive disease and in whom clamping and/or anastomosis is expected to be cumbersome or impossible.
Guedes, Marco Antonio Vieira; Pomerantzeff, Pablo Maria Alberto; Brandão, Carlos Manuel de Almeida; Vieira, Marcelo Luiz Campos; Grinberg, Max; Stolf, Noedir Antonio Groppo
2010-01-01
The right anterolateral thoracotomy is an alternative technique for surgical approach of mitral valve. In these cases, femoral-femoral bypass still has been used, rising occurrence of complications related to femoral cannulation. Describe the technique and results of mitral valve treatment by right anterolateral thoracotomy using aortic cannulation for cardiac pulmonary bypass (CPB). From 1983 e 2008, 100 consecutive female patients, with average age 35 ±13 years, 96 (96%) underwent mitral valve surgical treatment in the Heart Institute of São Paulo. A right anterolateral thoracotomy approach associated with aortic cannulation was used for CPB. Eighty (80%) patients had rheumatic disease and 84 (84%) patients presented functional class III or IV. Were performed 45 (45%) comissurotomies, 38 (38%) valve repairs, 7(7%) mitral valve replacements, seven (7%) recomissurotomies and three (3%) prosthesis replacement. Sparing surgery was performed in 90 (90%) patients. The average CPB and clamp time were 57 ± 27 min e 39 ± 19 min, respectively. There were no in-hospital death, reoperation due to bleeding and convertion to sternotomy. Introperative complications were related to heart harvest (5%), especially in reoperations (3%). The most important complications in postoperative period were related to pulmonary system (11%), followed by atrial fibrilation (10%) but without major systemic repercussions. The mean inhospital length of stay was 8 ± 3 days. Follow-up was 6.038 patients/month. Actuarial survival was 98.0 ± 1.9% and freedom from reoperation was 81.4 ± 7.8% in 180 months. The right anterolateral thoracotomy associated with aortic cannulation in mitral valve surgery is a simple technique, reproducible and safety.
The effects of L-carnitine on spinal cord ischemia/reperfusion injury in rabbits.
Tetik, O; Yagdi, T; Islamoglu, F; Calkavur, T; Posacioglu, H; Atay, Y; Ayik, F; Canpolat, L; Yuksel, M
2002-02-01
Paraplegia after distal aortic aneurysm repair remains a persistent clinical problem. We hypothesized that the tolerance of the spinal cord to an ischemic period could be improved with hypothermic Ringer's Lactate containing L-Carnitine. Twenty-eight New Zealand white rabbits were used as spinal cord ischemia models. We separated rabbits into four equal groups and clamped each animal's abdominal aorta distal to the left renal artery. We occluded the aortas above the iliac bifurcation for 30 minutes. In group I, the infrarenal aorta was clamped without infusing any solution. In group II, Ringer's Lactate solution was infused at + 25degrees C for 3 minutes at a rate of 5 ml/min into the isolated aortic segments immediately after cross-clamping and the last 3 minutes of ischemia. In group III, Ringer's Lactate solution at +3 degrees C was given in the same method as that of group II. In group IV, Ringer's Lactate solution at +3 degrees C plus 100 mg/kg of L-carnitine was infused using the same technique. We assessed the neurological status of the hind limbs 24 and 48 hours after operation according to Tarlov's criteria. All animals were sacrificed and spinal cords were harvested for histological analyses. The neurological status in groups III and IV was significantly superior to that of groups I and II. All the animals in group I had complete hind-limb paraplegia. Complete hind-limb paraplegia occurred in 5 rabbits in group II. Two of the 7 animals in group III had spastic paraplegia, and none at all in group IV. Histological analysis of the cross-clamped segments of the rabbits with paraplegia in group I, II and III revealed changes consistent with ischemic injury, while findings were normal for the normal animals in group III and IV. In this model, the infusion of hypothermic Ringer's Lactate contained L-carnitine provided sufficient spinal cord protection against ischemia. Clinically, this may be a useful adjunct for prevention of paraplegia during surgery of the descending aorta.
Thourani, Vinod H; Forcillo, Jessica; Szeto, Wilson Y; Kodali, Susheel K; Blackstone, Eugene H; Lowry, Ashley M; Semple, Marie; Rajeswaran, Jeevanantham; Makkar, Raj R; Williams, Mathew R; Bavaria, Joseph E; Herrmann, Howard C; Maniar, Hersh S; Babaliaros, Vasilis C; Smith, Craig R; Trento, Alfredo; Corso, Paul J; Pichard, Augusto D; Miller, D Craig; Svensson, Lars G; Kapadia, Samir; Ailawadi, Gorav; Suri, Rakesh M; Greason, Kevin L; Hahn, Rebecca T; Jaber, Wael A; Alu, Maria C; Leon, Martin B; Mack, Michael J
2018-05-01
The Placement of Aortic Transcatheter Valves 2A (PARTNER-2A) randomized trial compared outcomes of transfemoral transcatheter and surgical aortic valve replacement (SAVR) in intermediate-risk patients with severe aortic stenosis. The purpose of the present study was to perform an in-depth analysis of outcomes after SAVR in the PARTNER-2A trial. From January 2012 to January 2014, 937 patients underwent SAVR at 57 centers. Mean age was 82 ± 6.7 years and 55% were men. Less-invasive operations were performed in 140 patients (15%) and concomitant procedures in 198 patients (21%). Major outcomes and echocardiograms were adjudicated by an independent events committee. Follow-up was 94% complete to 2 years. Operative mortality was 4.1% (n = 38, Society of Thoracic Surgeons predicted risk of mortality: 5.2% ± 2.3%), observed to expected ratio (O/E) was 0.8, and in-hospital stroke was 5.4% (n = 51), twice expected. Aortic clamp and bypass times were 75 ± 30 minutes and 104 ± 46 minutes, respectively. Patients having severe prosthesis-patient mismatch (n = 260, 33%) had similar survival to patients without (p > 0.9), as did patients undergoing less-invasive SAVR (p = 0.3). Risk factors for death included cachexia (p = 0.004), tricuspid regurgitation (p = 0.01), coronary artery disease (p = 0.02), preoperative atrial fibrillation (p = 0.001), higher white blood cell count (p < 0.0001), and lower hemoglobin (p = 0.0002). In this adjudicated prospective study, SAVR in intermediate-risk patients had excellent results at 2 years. However, there were more in-hospital strokes than expected, most likely attributable to mandatory neurologic assessment after the procedure. No pronounced structural valve deterioration was found during 2-year follow-up. Continued long-term surveillance remains important. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Arnaoutakis, George J; Vallabhajosyula, Prashanth; Bavaria, Joseph E; Sultan, Ibrahim; Siki, Mary; Naidu, Suveeksha; Milewski, Rita K; Williams, Matthew L; Hargrove, W Clark; Desai, Nimesh D; Szeto, Wilson Y
2016-10-01
There remains concern that moderate hypothermic circulatory arrest (MHCA) with antegrade cerebral perfusion (ACP) may provide suboptimal distal organ protection compared with deep hypothermic circulatory arrest (DHCA) with retrograde cerebral perfusion (RCP). We compared postoperative acute kidney injury (AKI) in in patients who underwent elective hemiarch repair with either DHCA/RCP or MHCA/ACP. This was a retrospective review of all patients undergoing elective aortic hemiarch reconstruction for aneurysmal disease between 2009 and 2014. Patients were stratified according to the use of DHCA/RCP versus MHCA/ACP. The primary outcome was the occurrence of AKI at 48 hours, as defined by the Risk, Injury, Failure, Loss, End-Stage (RIFLE ) criteria. A multivariable logistic regression identified risk factors for AKI. One hundred eighteen patients who underwent ACP and 471 patients who underwent RCP were included. The mean lowest temperature was 26.4°C in patients who underwent MHCA/ACP and 17.5°C in patients who underwent DHCA/RCP. Baseline demographics were similar except that patients who underwent DHCA/RCP were more likely to have peripheral arterial disease or bicuspid aortic valves. Cardiopulmonary bypass and aortic cross-clamp times were shorter in the MHCA/ACP group. AKI occurred in 19 (16.2%) patients who underwent MHCA/ACP and 67 (14.3%) patients who underwent DHCA/RCP. Four (0.8%) patients who underwent DHCA/RCP required postoperative dialysis. In-hospital mortality tended to increase with increasing RIFLE classification (RIFLE class-0 (No AKI) = 0.41%; Risk = 1.35%, and Injury = 10.0%; p = 0.09). On multivariable analysis, the lowest temperature and cerebral perfusion strategy were not significant predictors of AKI. Lower baseline glomerular filtration rate (GFR), lower preoperative ejection fraction, and longer cardiopulmonary bypass (CPB) time were independently associated with higher AKI. We applied the sensitive RIFLE criteria to examine AKI in patients undergoing elective aortic hemiarch replacement for aneurysmal disease. Baseline renal dysfunction, lower ejection fraction, and longer CPB time are independent predictors of AKI. Compared with DHCA/RCP, our data suggest that an MHCA/ACP cerebral protection strategy does not appear to be associated with worse postoperative renal outcomes. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Spinal Ischemia in Thoracic Aortic Procedures: Impact of Radiculomedullary Artery Distribution.
Kari, Fabian A; Wittmann, Karin; Krause, Sonja; Saravi, Babak; Puttfarcken, Luisa; Förster, Katharina; Rylski, Bartosz; Maier, Sven; Göbel, Ulrich; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm
2017-12-01
The aim of this study was to assess the influence of thoracic anterior radiculomedullary artery (tARMA) distribution on spinal cord perfusion in a thoracic aortic surgical model. Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1). The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p < 0.001). We observed no detectable SCBF drop in the small-distance group: 0.2 ± 0.05 mL/g/min at baseline to 0.23 ± 0.05 mL/g/min immediately after clamping (p = 0.147). SCBF increased from 0.201 ± 0.055 mL/g/min at baseline to 0.443 ± 0.051 mL/g/min at 3 hours postoperatively (p < 0.001) only in the small-distance group. We demonstrate experimental data showing that distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bouma, Wobbe; Jainandunsing, Jayant S; Khamooshian, Arash; van der Harst, Pim; Mariani, Massimo A; Natour, Ehsan
2017-02-01
A thorough understanding of mitral and aortic valve motion dynamics is essential in mastering the skills necessary for performing successful valve intervention (open or transcatheter repair or replacement). We describe a reproducible and versatile beating-heart mitral and aortic valve assessment and valve intervention training model in human cadavers. The model is constructed by bilateral ligation of the pulmonary veins, ligation of the supra-aortic arteries, creating a shunt between the descending thoracic aorta and the left atrial appendage with a vascular prosthesis, anastomizing a vascular prosthesis to the apex and positioning an intra-aortic balloon pump (IABP) in the vascular prosthesis, cross-clamping the descending thoracic aorta, and finally placing a fluid line in the shunt prosthesis. The left ventricle is filled with saline to the desired pressure through the fluid line, and the IABP is switched on and set to a desired frequency (usually 60-80 bpm). Prerepair valve dynamic motion can be studied under direct endoscopic visualization. After assessment, the IABP is switched off, and valve intervention training can be performed using standard techniques. This high-fidelity simulation model has known limitations, but provides a realistic environment with an actual beating (human) heart, which is of incremental value. The model provides a unique opportunity to fill a beating heart with saline and to study prerepair mitral and aortic valve dynamic motion under direct endoscopic visualization. The entire set-up provides a versatile beating-heart mitral and aortic valve assessment model, which may have important implications for future valve intervention training. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Usui, A; Yasuura, K; Watanabe, T; Maseki, T
1999-05-01
Selection of a brain protection method is a primary concern for aortic arch surgery. We performed a retrospective study to compare the respective advantages and disadvantages of retrograde cerebral perfusion (RCP) and selective cerebral perfusion (SCP) in patients who underwent surgery for acute type A aortic dissection. The study reviewed 166 patients who underwent surgery at Nagoya University or its eight branch hospitals between January 1990 and August 1996. There were 91 patients who received SCP and 75 patients who underwent RCP. Results for these two groups were compared. There were no significant differences in age, gender, Marfan syndrome rate, DeBakey classification, or emergency operation rate. Rates of various preoperative complications were similar except for aortic valve regurgitation. Arch replacement was performed more often in SCP than in RCP patients (49% vs. 27%, P = 0.0028). There were no significant differences between groups in cardiac ischemic time or visceral organ ischemic time. However, RCP group showed shorter cardio-pulmonary bypass time (297+/-99 vs. 269+/-112 min, P = 0.013) and lower the lowest core temperature (21.6+/-3.1 degrees C vs. 18.7+/-2.1 degrees C, P = 0.0001). SCP duration was longer than RCP duration (103+/-56 vs. 54+/-24 min, P < 0.0001). Despite these differences, RCP patients were not significantly different from SCP patients with regard to any postoperative complication, neurological dysfunction (16 vs. 19%), or operative mortality (all deaths within the hospitalization; 24 vs. 21%). Regarding neurologic dysfunction, there were six cases of coma, six of motor paralysis, two of paraplegia and one of visual loss among SCP patients, and eight cases of coma, three of motor paralysis, and three of convulsion in the RCP group. The incidence of motor paralysis was higher in the SCP group, while the incidence of coma was higher in the RCP group. RCP can be performed without clamping or cannulation of the cervical arteries, which is an advantage in reducing the chances of arterial injury or cerebral embolization. RCP is comparable to SCP in terms of clinical outcome.
Minimally invasive aortic valve surgery. A safe and useful technique beyond the cosmetic benefits.
Paredes, Federico A; Cánovas, Sergio J; Gil, Oscar; García-Fuster, Rafael; Hornero, Fernando; Vázquez, Alejandro; Martín, Elio; Mena, Armando; Martínez-León, Juan
2013-09-01
The aim of this study was to compare the in-hospital clinical outcomes of minimally invasive, isolated aortic valve replacement vs median sternotomy. Between 2005 and 2012, 615 patients underwent aortic valve replacement at a single institution, 532 by a median sternotomy (E group) and 83 by a J-shaped ministernotomy (M group). No significant differences were found between the E and M groups in terms of age (69.27 [9.31] years vs 69.40 [10.24] years, respectively), logistic EuroSCORE (6.27 [2.91] vs 5.64 [2.17], respectively), size of implanted valve prosthesis (21.94 [2.04] mm vs 21.79 [2.01] mm, respectively), or the incidence of diabetes, hypercholesterolemia, high blood pressure, or chronic obstructive pulmonary disease. Mean cardiopulmonary bypass time was 102.90 (41.68) min for the E group vs 81.37 (25.41) min for the M group (P<.001). Mean cross-clamp time was 77.31 (29.20) min vs 63.45 (17.71) min for the S and M groups, respectively (P<.001). Mortality in the E group was 4.88% (26). There were no deaths in the M group (P<.05). The E group was associated with longer intensive care unit and hospital stays: 4.17 (5.23) days vs 3.22 (2.01) days (P=.045) and 9.58 (7.66) days vs 7.27 (3.83) days (P<.001), respectively. E group patients had more postoperative respiratory complications (42 [8%] vs 1 [1.2%]; P<.05). There were no differences when postoperative hemodynamic, neurologic, and renal complications, systemic infection, and wound infection were analyzed. In terms of morbidity, mortality, and operative times, outcomes after minimally invasive surgery for aortic valve replacement are at least comparable to those achieved with median sternotomy. The length of the hospital stay was reduced by minimally invasive surgery in our single-institution experience. The retrospective nature of this study warrants further randomized prospective trials to validate our results. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Use of the Abdominal Aortic Tourniquet for Hemorrhage Control
2016-06-01
compression to the aorta at the abdominal-pelvic junction to occlude blood flow in the common iliac and inguinal arteries. The target of the compression...circumferential device that utilizes a belt, windlass and pneumatic pressure to compress the aorta . The belt and windlass together greatly increase the...clamping the aorta or fully stopping all blood flow to the pelvis and lower extremities. In essence the AAT™ acts as a valve to figuratively ‘turn the
Improved Survival After the Ross Procedure Compared With Mechanical Aortic Valve Replacement.
Buratto, Edward; Shi, William Y; Wynne, Rochelle; Poh, Chin L; Larobina, Marco; O'Keefe, Michael; Goldblatt, John; Tatoulis, James; Skillington, Peter D
2018-03-27
It is unclear whether the Ross procedure offers superior survival compared with mechanical aortic valve replacement (AVR). This study evaluated experience and compared long-term survival between the Ross procedure and mechanical AVR. Between 1992 and 2016, a total of 392 Ross procedures were performed. These were compared with 1,928 isolated mechanical AVRs performed during the same time period as identified using the University of Melbourne and Australia and New Zealand Society of Cardiac and Thoracic Surgeons' Cardiac Surgery Databases. Only patients between 18 and 65 years of age were included. Propensity-score matching was performed for risk adjustment. Ross procedure patients were younger, and had fewer cardiovascular risk factors. The Ross procedure was associated with longer cardiopulmonary bypass and aortic cross-clamp times. Thirty-day mortality was similar (Ross, 0.3%; mechanical, 0.8%; p = 0.5). Ross procedure patients experienced superior unadjusted long-term survival at 20 years (Ross, 95%; mechanical, 68%; p < 0.001). Multivariable analysis showed the Ross procedure to be associated with a reduced risk of late mortality (hazard ratio: 0.34; 95% confidence internal: 0.17 to 0.67; p < 0.001). Among 275 propensity-score matched pairs, Ross procedure patients had superior survival at 20 years (Ross, 94%; mechanical, 84%; p = 0.018). In this Australian, propensity-score matched study, the Ross procedure was associated with better long-term survival compared with mechanical AVR. In younger patients, with a long life expectancy, the Ross procedure should be considered in centers with sufficient expertise. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.
[Effect of urapidil combined with phentolamine on hypertension during extracorporeal circulation].
Wang, Fangjun; Chen, Bin; Liu, Yang; Tu, Faping
2014-08-01
To study the effect of urapidil combined with phentolamine in the management of hypertension during extracorporeal circulation. Ninety patients undergoing aortic and mitral valve replacement were randomly divided into 3 equal groups to receive treatment with phentolamine (group A), urapidil (group B), or both (group C) during extracorporeal circulation. The mean arterial pressure (MAP) before and after drug administration, time interval of two administrations, spontaneous recovery of heart beat after aorta unclamping, ventricular arrhythmia, changes of ST-segment 1 min after the recovery of heart beat, ante-parallel cycle time, aorta clamping time, post-parallel cycle time, dopamine dose after cardiac resuscitation, and perioperative changes of plasma TNF-α and IL-6 levels were recorded. There was no significant difference in MAP between the 3 groups before or after hypotensive drug administration (P>0.05). The time interval of two hypotensive drug administrations was longer in group C than in groups A and B (P<0.05). The incidence of spontaneous recovery of heart beat after aorta unclamping, incidence of ventricular arrhythmia, changes of ST-segment 1 min after the recovery of heart beat, ante-parallel cycle time, aorta clamping time, and post-parallel cycle time were all comparable between the 3 groups. The dose of dopamine administered after cardiac resuscitation was significantly larger in group B than in groups A or group C (P<0.05). The plasma levels of TNF-α and IL-6 were significantly increased after CPB and after the operation in all the groups, but were lowed in group C than in groups A and B at the end of CPB and at 2 h and 12 after the operation. Urapidil combined with phentolamine can control hypertension during extracorporeal circulation without causing hypotension.
Majewski, Wacław; Krzyminiewski, Ryszard; Stanisić, Michał; Iskra, Maria; Krasiński, Zbigniew; Nowak, Marek; Dobosz, Bernadeta
2014-11-27
Aortic cross-clamping during abdominal aortic aneurysm (AAA) open repair leads to development of ischemia-reperfusion injury. Electron paramagnetic resonance spectroscopy (EPR) spin-trapping is a valuable method of direct measurement of free radicals. The objective of the study was to evaluate the results of EPR as a direct method of free radical measurement and degree of inflammatory response in open operative treatment of patients with AAA and aorto-iliac occlusive disease (AIOD). The study was performed on a group of 32 patients with AAA and 25 patients with AIOD scheduled for open repair. Peripheral venous blood for EPR spectroscopy and for SOD, GPx, ox-LDL, Il-6, TNF-alfa, CRP, and HO-1 were harvested. Selected parameters were established accordingly to specified EPR and immunohistochemical methods and analyzed between groups by Mann-Whitney U test and Wilcoxon matched-pairs signed-ranks test with Bonferroni correction. Free radicals level was correlated with the time of the aortic cross-clamping after the reperfusion of he first and second leg in AAA (r=0.7; r=0.47). ox-LDL in AAA decreased 5 min after reperfusion of the first leg (32.99 U/L, range: 14.09-77.12) and 5 min after reperfusion of the second leg (26.75 U/L, range: 11.56-82.12) and 24 h after the operation (25.85 U/L, range: 14.29-49.70). HO-1 concentration increased to above the level before intervention 24 h after surgery. The activities of GPx and SOD decreased 5 min after the first-leg reperfusion in AAA. Twenty-four hours after surgery, inflammatory markers increased in AAA to CRP was 14.76 ml/l (0.23-38.55), IL-6 was 141.22 pg/ml (84.3-591.03), TNF-alfa was 6.82 pg/ml (1.76-80.01) and AIOD: CRP was 18.44 mg/l (2.56-33.14), IL-6: 184.1 pg/ml (128.46-448.03), TNF-alfa was 7.74 pg/ml (1.74-74.74). EPR spin-trapping demonstrates temporarily elevated level of free radicals in early phase of reperfusion, leading to decrease antioxidants in AAA. Elevated free radical levels decreased 24 h after surgery due to various endogenous antioxidants and therapies.
Traumatic rupture of the aortic isthmus: program of selective management.
Pate, J W; Gavant, M L; Weiman, D S; Fabian, T C
1999-01-01
Two hypotheses were investigated: (1) helical computed tomography (CT) of the chest on victims of decelerating trauma can yield a diagnosis of, or "rule out," a traumatic rupture of the aorta (TRA) without the need for an aortogram; and (2) selective delay of aortic repair can be safely accomplished through a medical management protocol. Screening helical CT examinations were done on 6169 victims of blunt thoracic trauma; 47 were found to have TRA; in 8, indirect but nondiagnostic findings not clarified by an aortogram led to surgical exploration. The sensitivity of helical CT was higher than that of aortograms, and a "normal" helical CT scan was never associated with a proved TRA. It is estimated that the use of helical CT has resulted in at least a 40% to 50% decrease in the need for aortograms, in addition to yielding rapid, noninvasive valuable information about other injuries. Drugs (beta-blockers +/- vasodilators) to decrease the stress in the aortic wall were used in 93 patients when the diagnosis was suspected and were continued as necessary through the evaluation, stabilization, and until the aorta was cross-clamped at operation. Elective, delayed operation was done between 2 days and 25 months in 15 patients who were deemed to be excessive risks for emergency aortic repair; there were 2 deaths (13. 3%). Eleven patients never had aortic repair. No patient maintained on this protocol, whether repaired emergently, electively, or not at all, developed free rupture of the periaortic hematoma and death from TRA.
Bell, Marshall T; Puskas, Ferenc; Smith, Phillip D; Agoston, Viktor A; Fullerton, David A; Meng, Xianzhong; Weyant, Michael J; Reece, T Brett
2012-11-01
Despite surgical adjuncts, paralysis remains a devastating complication after thoracoabdominal aortic interventions. Dexmedetomidine, a selective α-2a agonist commonly used for sedation in the critical care setting, has been shown to have protective effects against ischemia-reperfusion injuries in multiple organ systems. We hypothesized that treatment with dexmedetomidine would attenuate spinal cord ischemia-reperfusion injury via α-2a receptor activation. Adult C57BL/6 mice underwent sternotomy, followed by occlusion of the aortic arch for 4 minutes. Eight experimental mice received pretreatment with intraperitoneal dexmedetomidine (25 μg/kg) and at 12-hour intervals after reperfusion. Eight control mice received an equivalent amount of 0.9% normal saline. Five mice underwent the same procedure with dexmedetomidine (25 μg/kg) and atipamezole (250 μg/kg), an α-2a receptor antagonist. Functional analysis of the mice was obtained at 12-hour intervals and scored using the Basso Mouse Scale for Locomotion until 60 hours. All mice were euthanized at 60 hours. Their spinal cords were removed en bloc and were stained with hematoxylin and eosin to assess cytoarchitecture and neuronal viability. Mice treated with the α-2a agonist demonstrated preserved motor function compared with ischemic controls and with mice treated with the α-2a antagonist in addition to the agonist. Functional differences in the dexmedetomidine group were statistically significant from 24 hours through the remainder of the experiment (P < .05). In addition, the treated mice had preserved cytoarchitecture, decreased vacuolization, and improved neuronal viability compared with ischemic control mice and mice concurrently treated with atipamezole, the dexmedetomidine α-2a antagonist. Treatment of mice with the α-2a agonist dexmedetomidine preserves motor function and neuronal viability after aortic cross-clamping. In addition, mice exhibited almost complete reversal of the protective effect with the administration of the α-2a receptor antagonist atipamezole. Dexmedetomidine appears to attenuate spinal cord ischemia-reperfusion injury via α-2a receptor-mediated agonism. There remains a significant risk of paraplegia after thoracoabdominal aortic interventions. This complication is devastating to the patient and the health care system. Pharmacologic adjuncts to further decrease this complication have been studied; however, few viable options exist. The α-2a agonists have been shown to improve outcomes after strokes but have not been studied in spinal cord ischemia. We show that dexmedetomidine, a commonly used α-2a agonist in the operating room, can preserve neurologic function in mice after aortic cross-clamping. Although the protective mechanism of dexmedetomidine remains unknown, it might prove to be beneficial in reducing the incidence of paraplegia after aortic interventions. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Pantsios, Chris; Kapelios, Chris; Vakrou, Styliani; Diakos, Nikolaos; Pozios, Iraklis; Kontogiannis, Chris; Nanas, John; Malliaras, Konstantinos
2016-07-01
The "no reflow" phenomenon (microvascular obstruction despite restoration of epicardial blood flow) develops postreperfusion in acute myocardial infarction and is associated with poor prognosis. We hypothesized that increased reperfusion pressure may attenuate the no reflow phenomenon, as it could provide adequate flow to overcome the high resistance of the microvasculature within the no reflow zone. Thus, we investigated the effect of modestly elevated blood pressure during reperfusion on the extent of no reflow area and infarct size in a porcine model of ischemia-reperfusion. Eighteen farm pigs underwent acute myocardial infarction by occlusion of the anterior descending coronary artery for 1 hour, followed by 2 hours of reperfusion. Just prior to reperfusion, animals were randomized into 2 groups: in group 1 (control group, n = 9), no intervention was performed. In group 2 (n = 9), aortic pressure was increased by ∼20% (compared to ischemia) by partial clamping of the ascending aorta during reperfusion. Following 2 hours of reperfusion, animals were euthanized to measure area at risk, infarct size, and area of no reflow. Partial clamping of the ascending aorta resulted in modest elevation of blood pressure during reperfusion. The area at risk did not differ between the 2 groups. The no reflow area was significantly increased in group 2 compared to control animals (50% ± 13% vs 37% ± 9% of the area at risk; P = .04). The infarcted area was significantly increased in group 2 compared to control animals (75% ± 17% vs 52% ± 23% of the area at risk; P = .03). Significant positive correlations were observed between systolic aortic pressure and no reflow area, between systolic aortic pressure and infarcted area and between infarcted area and no reflow area during reperfusion. Modestly elevated blood pressure during reperfusion is associated with an increase in no reflow area and in infarct size in a clinically relevant porcine model of ischemia-reperfusion. © The Author(s) 2015.
Stenseth, R; Nilsen, T; Haaverstad, R; Vitale, N; Dale, O
2007-11-01
During cardiopulmonary bypass (CPB), hypoperfusion and reperfusion may cause oxidative stress and lipid peroxidation that generates ethane. The aim of this pilot study was to assess the feasibility of frequent sampling of exhaled ethane during cardiac surgery. After approval of the Research Ethics Committee, 10 patients undergoing combined aortic valve and coronary artery bypass surgery were enrolled. Breath samples were drawn in the perioperative period and analyzed by a rapid, sensitive and validated gas-chromatographic method. Increased exhaled ethane was regularly seen following sternotomy, after the start of CPB and after aortic clamp removal, whereas no change was seen after termination of bypass. In one patient, the maximum increase in exhaled ethane was 30-fold. Peak durations lasted only 2-4 min. This study demonstrates that frequent sampling of breath ethane is feasible in a clinical setting, allowing detection of rapid ethane surges of short duration.
Atresia of the Descending Aorta in a Young Woman Requiring Bypass Graft.
Dsc, Adcasdc Sadfasdf; Mashhood, Ammarah; Ali, Taimur Asif; Fatimi, Saulat Hasnain
2016-11-01
Congenital aortic atresia is a malformation accounting for 4 - 6% of all congenital heart diseases in children. Left ventricular outflow obstruction due to atresia is common at the aortic valve but rarely has atresia been identified in the descending aorta. We report the case of a 25-year woman who was evaluated for headache and uncontrolled hypertension. CTscan chest showed a short atretic segment in the descending aorta at the isthmus, distal to the takeoff of the subclavian artery. She underwent surgery; a 22 mm Dacron graft was taken and jump graft was placed between the arch of the aorta and the descending aorta, using partial occlusion clamps. Patient tolerated the procedure well and was discharged on ACE Inhibitors and beta blockers, which were then weaned off over a period of one year. She remained stable and had no further complaints.
Recurrent Laryngeal Nerve Injury and Swallowing Dysfunction in Neonatal Aortic Arch Repair.
Pourmoghadam, Kamal K; DeCampli, William M; Ruzmetov, Mark; Kosko, James; Kishawi, Sami; O'Brien, Michael; Cowden, Amanda; Piggott, Kurt; Fakioglu, Harun
2017-11-01
We evaluated the incidence, clinical effect, and recovery rate of vocal cord dysfunction (VCD) and swallowing dysfunction in neonates undergoing aortic arch repair. We retrospectively evaluated 101 neonates who underwent aortic arch reconstruction from 2008 to 2015. Direct flexible laryngoscopy was performed in 89 patients before initiation of postoperative oral feeding after Norwood (n = 63) and non-Norwood (n = 26) arch reconstruction. We defined VCD as immobility of vocal cords or their lack of coaptation and poor mobility. The incidence of VCD after aortic arch repair was 48% (n = 43). There was no significant difference between the VCD and non-VCD groups in postoperative length of stay, extubation failure, cardiopulmonary bypass, cross-clamp, selective cerebral perfusion time, operative death, and The Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery (STAT) Congenital Heart Surgery Mortality Categories. Placement of gastrostomy (p = 0.03) and documented aspiration (p = 0.01) were significantly more common in VCD patients. The incidence of VCD was 41% (n = 26) after Norwood and 65% (n = 17) after non-Norwood repairs (p = 0.06). Gastrostomy was required in 44 Norwood patients vs 9 non-Norwood patients (p = 0.004). Median length of stay was similar in Norwood patients with or without VCD (p = .28) but was significantly longer in non-Norwood patients with VCD vs those without (p = 0.002). At follow-up direct flexible laryngoscopy, VCD recovery was 74% (14 of 19) in the Norwood group and 86% (12 of 14) in the non-Norwood group. The incidence of VCD and swallowing dysfunction in neonates undergoing aortic arch reconstruction is high. Patients with VCD have a significantly higher incidence of gastrostomy placement and aspiration. In the Norwood population, length of stay is not associated with presence or absence of VCD. More than 70% of patients in each group who had direct flexible laryngoscopy follow-up recovered vocal cord function. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Pianigiani, E; Tognetti, L; Ierardi, F; Mariotti, G; Rubegni, P; Cevenini, G; Perotti, R; Fimiani, M
2016-06-01
Skin allografts from cadaver donors are an important resource for treating extensive burns, slow-healing wounds and chronic ulcers. A high level of cell viability of cryopreserved allografts is often required, especially in burn surgery, in Italy. Thus, we aimed to determine which conditions enable procurement of highly viable skin in our Regional Skin Bank of Siena. For this purpose, we assessed cell viability of cryopreserved skin allografts procured between 2011 and 2013 from 127 consecutive skin donors, before and after freezing (at day 15, 180, and 365). For each skin donor, we collected data concerning clinical history (age, sex, smoking, phototype, dyslipidemia, diabetes, cause of death), donation process (multi-tissue or multi-organ) and timing of skin procurement (assessment of intervals such as death-harvesting, harvesting-banking, death-banking). All these variables were analysed in the whole case study (127 donors) and in different groups (e.g. multi-organ donors, non refrigerated multi-tissue donors, refrigerated multi-tissue donors) for correlations with cell viability. Our results indicated that cryopreserved skin allografts with higher cell viability were obtained from female, non smoker, heartbeating donors died of cerebral haemorrhage, and were harvested within 2 h of aortic clamping and banked within 12 h of harvesting (13-14 h from clamping). Age, cause of death and dyslipidaemia or diabetes did not appear to influence cell viability. To maintain acceptable cell viability, our skin bank needs to reduce the time interval between harvesting and banking, especially for refrigerated donors.
Sabashnikov, Anton; Heinen, Stephanie; Deppe, Antje Christin; Zeriouh, Mohamed; Weymann, Alexander; Slottosch, Ingo; Eghbalzadeh, Kaveh; Popov, Aron-Frederik; Liakopoulos, Oliver; Rahmanian, Parwis B; Madershahian, Navid; Kroener, Axel; Choi, Yeong-Hoon; Kuhn-Régnier, Ferdinand; Simon, André R; Wahlers, Thorsten; Wippermann, Jens
2017-05-01
Previous research suggests that female gender is associated with increased mortality rates after surgery for Stanford A acute aortic dissection (AAD). However, women with AAD usually present with different clinical symptoms that may bias outcomes. Moreover, there is a lack of long-term results regarding overall mortality and freedom from major cerebrovascular events. We analysed the impact of gender on long-term outcomes after surgery for Stanford A AAD by comparing genders with similar risk profiles using propensity score matching. A total of 240 patients operated for Stanford A AAD were included in this study. To control for selection bias and other confounders, propensity score matching was applied to gender groups. After propensity score matching, the gender groups were well balanced in terms of risk profiles. There were no statistically significant differences regarding duration of cardiopulmonary bypass ( P = 0.165) and duration of aortic cross-clamp time ( P = 0.111). Female patients received less fresh frozen plasma ( P = 0.021), had shorter stays in the intensive care unit ( P = 0.031), lower incidence of temporary neurological dysfunction ( P < 0.001) and lower incidence of dialysis ( P = 0.008). There were no significant differences regarding intraoperative mortality ( P = 1.000), 30-day mortality ( P = 0.271), long-term overall cumulative survival ( P = 0.954) and long-term freedom from cerebrovascular events ( P = 0.235) with up to a 9-year follow-up. Considering patients with similar risk profiles, female gender per se is not associated with worse long-term survival and freedom from stroke after surgical aortic repair. Moreover, female patients might even benefit from a smoother early postoperative course and lower incidence of early postoperative complications. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
A novel high performance ESD power clamp circuit with a small area
NASA Astrophysics Data System (ADS)
Zhaonian, Yang; Hongxia, Liu; Li, Li; Qingqing, Zhuo
2012-09-01
A MOSFET-based electrostatic discharge (ESD) power clamp circuit with only a 10 ns RC time constant for a 0.18-μm process is proposed. A diode-connected NMOSFET is used to maintain a long delay time and save area. The special structure overcomes other shortcomings in this clamp circuit. Under fast power-up events, the gate voltage of the clamp MOSFET does not rise as quickly as under ESD events, the special structure can keep the clamp MOSFET thoroughly off. Under a falsely triggered event, the special structure can turn off the clamp MOSFET in a short time. The clamp circuit can also reject the power supply noise effectively. Simulation results show that the clamp circuit avoids fast false triggering events such as a 30 ns/1.8 V power-up, maintains a 1.2 μs delay time and a 2.14 μs turn-off time, and reduces to about 70% of the RC time constant. It is believed that the proposed clamp circuit can be widely used in high-speed integrated circuits.
Ohira, Suguru; Doi, Kiyoshi; Numata, Satoshi; Yamazaki, Sachiko; Itatani, Keiichi; Kawajiri, Hidetake; Morimoto, Kazuki; Yaku, Hitoshi
2017-10-01
To investigate the results of off-pump coronary artery grafting (OPCAB) with the proximal suture device (PSD) regarding postoperative stroke and graft patency. The PSD was used in 376 patients (32.0%), aorta-no-touch OPCAB was performed in 523 patients (45.2%), on-pump beating coronary artery bypass surgery (CABG) (on-beat group) in 125 patients (10.6%) including 51 conversions (conversion rate: 5.4%), and CABG with aortic clamp use (clamp group) in 152 patients. In the PSD group, Enclose II was used in 267 patients (71.0%). The hospital mortality rate was 1.95%. There was no early stroke in the OPCAB group, whereas the early-stroke rate was 0.8% in the on-beat group and 2.6% in the clamp group. The incidences of stroke at one month were: PSD group, 1.6%; no-touch group, 1.1%; on-beat group, 1.6%; and clamp group, 4.6% (p=0.014). The rates of complete revascularisation were higher in the PSD and clamp groups (94.7 and 94.0%, respectively) compared with the no-touch and on-beat groups (81.5 and 84.9%, respectively; p<0.001). The vein graft patency rates were comparable between the PSD and clamp groups. In multiple logistic regression analysis, OPCAB using the PSD did not increase the risk of stroke compared with the no-touch group (adjusted odds ratio [AOR]: 1.40; p=0.594) or on-beat group (AOR: 0.99; p=0.206), but reduced the risk of stroke compared with the clamp group (AOR: 0.19; p=0.005). Off-pump coronary artery grafting using the PSD was a safe and effective procedure. It led to lower incidences of postoperative stroke and excellent rates of graft patency and complete revascularisation compared with conventional CABG. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Balcı, Ahmet Yavuz; Vural, Unsal; Özdemir, MD Fatih; Kızılay, Mehmet; Şenocak, Mutlu; Kayacıoğlu, Ilyas; Yekeler, Ibrahim; Aksoy, Rezan; Satılmış,, Seçkin; Şaşkın, Huseyin
2017-01-01
Summary Background: This study was designed to determine the short- and long-term effects of proximal aortic anastomosis, performed during isolated coronary artery bypass grafting (CABG) in patients with dilatation of the ascending aorta who did not require surgical intervention. Methods: The study was performed on 192 (38 female and 160 male patients; mean age, 62.1 ± 9.2 years; range, 42–80 years) patients with dilatation of the ascending aorta who underwent CABG surgery between 1 June 2006 and 31 May 2014. In group 1 (n = 114), the saphenous vein and left internal mammarian artery grafts were used, and proximal anastomosis was performed on the ascending aorta. In group 2 (n = 78), left and right internal mammarian artery grafts were used, and proximal aortic anastomosis was not performed. Pre-operatively and in the first and third years postoperatively, the ascending aortic diameter was measured and recorded using transthoracic echocardiography at four different regions (annulus, sinus of Valsalva, sinotubular junction and tubular aorta). Results: A statistically significant difference was found between the groups for the number of grafts used and the duration of aortic cross-clamping and cardiopulmonary bypass. No significant intergroup difference was seen for the mean diameter of the ascending aorta (p > 0.05). Annual changes in the aortic diameter were found to be extremely significantly different in both groups (p = 0.0001). Mean values of the aortic diameter at the level of the sinotubular junction and tubular ascending aorta, mean aortic diameters (p = 0.002 and p = 0.0001, respectively), annual increase in diameter (p = 0.0001 and p = 0.0001, respectively), and mean annual difference in diameter (p = 0.0001 and p = 0.0001, respectively) at one and three years postoperatively were statistically significantly different between the groups. Conclusion: In patients with ascending aortic dilatation who did not require surgical intervention and who had proximal anastomosis of the ascending aorta and underwent only CABG, we detected statistically significant increases in the diameter of the sinotubular junction and tubular aorta up to three years postoperatively. PMID:27701487
Yavuz Balci, Ahmet; Vural, Unsal; Aksoy, Rezan; Özdemir, M Fatih; Satilmiş, Seçkin; Kizilay, Mehmet; Şenocak, Mutlu; Şaşkin, Huseyin; Kayacioğlu, Ilyas; Yekeler, Ibrahim
This study was designed to determine the short- and long-term effects of proximal aortic anastomosis, performed during isolated coronary artery bypass grafting (CABG) in patients with dilatation of the ascending aorta who did not require surgical intervention. The study was performed on 192 (38 female and 160 male patients; mean age, 62.1 ± 9.2 years; range, 42-80 years) patients with dilatation of the ascending aorta who underwent CABG surgery between 1 June 2006 and 31 May 2014. In group 1 (n = 114), the saphenous vein and left internal mammarian artery grafts were used, and proximal anastomosis was performed on the ascending aorta. In group 2 (n = 78), left and right internal mammarian artery grafts were used, and proximal aortic anastomosis was not performed. Pre-operatively and in the first and third years postoperatively, the ascending aortic diameter was measured and recorded using transthoracic echocardiography at four different regions (annulus, sinus of Valsalva, sinotubular junction and tubular aorta). A statistically significant difference was found between the groups for the number of grafts used and the duration of aortic cross-clamping and cardiopulmonary bypass. No significant intergroup difference was seen for the mean diameter of the ascending aorta (p > 0.05). Annual changes in the aortic diameter were found to be extremely significantly different in both groups (p = 0.0001). Mean values of the aortic diameter at the level of the sinotubular junction and tubular ascending aorta, mean aortic diameters (p = 0.002 and p = 0.0001, respectively), annual increase in diameter (p = 0.0001 and p = 0.0001, respectively), and mean annual difference in diameter (p = 0.0001 and p = 0.0001, respectively) at one and three years postoperatively were statistically significantly different between the groups. In patients with ascending aortic dilatation who did not require surgical intervention and who had proximal anastomosis of the ascending aorta and underwent only CABG, we detected statistically significant increases in the diameter of the sinotubular junction and tubular aorta up to three years postoperatively.
Aortic valve replacement in octogenarians.
Bose, Amal K; Aitchison, James D; Dark, John H
2007-07-13
As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR) in octogenarians. 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37) underwent isolated AVR whilst 46% (31) underwent combined AVR and CABG. Follow up was 100% complete. The mean age was 83.1 +/- s.d. 2.9 years, a mean gradient of 83 +/- s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 +/- s.d. 1.2, the logistic EuroSCORE mean 12.0 +/- s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p < 0.05). Survival was not adversely affected by the addition of coronary artery bypass grafts to aortic valve replacement, the presence of peripheral vascular disease, hypertension or diabetes. In this study duration of cross clamp or bypass time were not found to reach significance as independent predictors of mortality. Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.
Duncan, Andra E.; Kashy, Babak Kateby; Sarwar, Sheryar; Singh, Akhil; Stenina-Adognravi, Olga; Christoffersen, Steffen; Alfirevic, Andrej; Sale, Shiva; Yang, Dongsheng; Thomas, James D.; Gillinov, Marc; Sessler, Daniel I.
2015-01-01
Background Glucose-insulin-potassium (GIK) administration during cardiac surgery inconsistently improves myocardial function, perhaps because hyperglycemia negates the beneficial effects of GIK. The hyperinsulinemic normoglycemic clamp (HNC) technique may better enhance the myocardial benefits of GIK. We extended previous GIK investigations by: 1) targeting normoglycemia while administering a glucose-insulin-potassium infusion (HNC); 2) using improved echocardiographic measures of myocardial deformation, specifically myocardial longitudinal strain and strain rate; and, 3) assessing activation of glucose metabolic pathways. Methods 100 patients having aortic valve replacement for aortic stenosis were randomly assigned to HNC (high-dose insulin with concomitant glucose infusion titrated to normoglycemia) versus standard therapy (insulin treatment if glucose >150 mg/dL). Our primary outcomes were left ventricular longitudinal strain and strain rate, assessed using speckle-tracking echocardiography. Right atrial tissue was analyzed for activation of glycolysis/pyruvate oxidation and alternative metabolic pathways. Results Time-weighted mean glucose concentrations were lower with HNC (127±19 mg/dL) than standard care (177±41 mg/dL; P<0.001). Echocardiographic data were adequate in 72 patients for strain analysis and 67 patients for strain rate analysis. HNC did not improve myocardial strain, with an HNC minus standard therapy difference of −1.2 (97.5%CI: −2.9, 0.5)%; P=0.11. Strain rate was significantly better, but by a clinically unimportant amount: −0.16 (−0.30, −0.03) sec−1, P = 0.007. There was no evidence of increased glycolytic, pyruvate oxidation, or hexosamine biosynthetic pathway activation in right atrial samples (n = 20, HNC; 22, standard therapy). Conclusions Administration of glucose and insulin while targeting normoglycemia during aortic valve replacement did not meaningfully improve myocardial function. PMID:26200180
Solomon, Cristina; Rahe-Meyer, Niels
2015-01-01
Background Administration of fibrinogen concentrate, targeting improved maximum clot firmness (MCF) of the thromboelastometric fibrin-based clot quality test (FIBTEM) is effective as first-line haemostatic therapy in aortic surgery. We performed a post-hoc analysis of data from a randomised, placebo-controlled trial of fibrinogen concentrate, to investigate whether fibrinogen concentrate reduced transfusion requirements for patients with platelet counts over or under 100×109/L. Material and methods Aortic surgery patients with coagulopathic bleeding after cardiopulmonary bypass were randomised to receive either fibrinogen concentrate (n=29) or placebo (n=32). Platelet count was measured upon removal of the aortic clamp, and coagulation and haematology parameters were measured peri-operatively. Transfusion of allogeneic blood components was recorded and compared between groups. Results After cardiopulmonary bypass, haemostatic and coagulation parameters worsened in all groups; plasma fibrinogen level (determined by the Clauss method) decreased by 43–58%, platelet count by 53–64%, FIBTEM maximum clot firmness (MCF) by 38–49%, FIBTEM maximum clot elasticity (MCE) by 43–54%, extrinsically activated test (EXTEM) MCF by 11–22%, EXTEM MCE by 25–41% and the platelet component of the clot by 23–39%. Treatment with fibrinogen concentrate (mean dose 7–9 g in the 4 groups) significantly reduced post-operative allogeneic blood component transfusion requirements when compared to placebo both for patients with a platelet count ≥100×109/L and for patients with a platelet count <100×109/L. Discussion FIBTEM-guided administration of fibrinogen concentrate reduced transfusion requirements when used as a first-line haemostatic therapy during aortic surgery in patients with platelet counts over or under 100×109/L. PMID:25369608
Sokol, Kyle K; Black, George E; Willey, Sandra B; Kniery, Kevin; Marko, Shannon T; Eckert, Matthew J; Martin, Matthew J
2017-01-01
Advances in thermal imaging devices have made them an appealing noninvasive point-of-care imaging adjunct in the trauma setting. We sought to assess whether a smartphone-based infrared imaging device (SBIR) could determine presence and location of aortic occlusion in a swine model. We hypothesized that various levels of aortic occlusion would transmit significantly different heat signatures at various anatomical points. Six swine (35-50 kg) underwent sequential zone 1 (Z1) aortic cross clamping as well as zone 3 (Z3) aortic balloon occlusion (resuscitative endovascular balloon occlusion of the aorta [REBOA]). SBIR images and readings (FLIR One) were taken at five anatomic points (axilla [A], subcostal [S], umbilical [U], inguinal [I], medial malleolar [M]) and were used to determine significant thermal trends 5 minutes to 10 minutes after Z1 and Z3 occlusion. Significant (p ≤ 0.05) thermal ratio patterns were identified and compared among groups, and images were reviewed for obvious qualitative differences at the various levels of occlusion. Body temperatures were similar during control (CON), Z1 occlusion, and Z3 occlusion, ranging from 94.0 °F to 100.9 °F (p = 0.126). No significant temperature differences were found among A, S, U, I, M points prior to and after aortic occlusions. Among the anatomical 2-point ratios evaluated, A/M and S/M ratios were the best predictors of aortic occlusion, whether at Z1 (8.2 °F, p < 0.01; 10.9 °F, p < 0.01) or Z3 (7.3 °F, p < 0.01; 8.4 °F, p < 0.01), respectively. The best predictor of Z1 versus Z3 level of occlusion was the S/I ratio (5.2 °F, p < 0.05 vs. 3.4 °F, p = 0.27). SBIR generated qualitatively different thermal signatures among groups. SBIR was capable of detecting thermal trends during Z1 and Z3 aortic occlusion by using an anatomical 2-point thermal ratio. There were also easily recognized qualitative differences between control and occlusion images that would allow immediate determination of adequate occlusion of the aorta. SBIR represents a potential inexpensive and accurate tool for assessing perfusion, adequate REBOA placement, and even the aortic level of occlusion.
Mithiran, Harish; Kunnath Bonney, Glenn; Bose, Saideep; Subramanian, Srinivas; Zhe Yan, Zan Ng; Zong En, Seth Yeak; Papadimas, Evangelos; Chauhan, Ishaan; MacLaren, Graeme; Kofidis, Theodoros
2016-10-01
To develop a scoring system to predict acute kidney injury in Asian patients after coronary artery bypass grafting. A retrospective analysis of data collected in an institutional cardiac database. A tertiary academic hospital in a large metropolitan city. The study comprised 954 patients with coronary artery disease. All patients underwent coronary artery bypass surgery with cardiopulmonary bypass but did not undergo any other concomitant procedures. The main outcome measured was acute kidney injury as defined by the Acute Kidney Injury Network criteria. The following 6 clinical variables were independent predictors of kidney injury: age>60 years, diabetes requiring insulin, estimated glomerular filtration rate<60 mL/min/1.73 m(2), ejection fraction<40%, cardiopulmonary bypass time>140 minutes, and aortic cross-clamp time>100 minutes. These variables were used to develop the Singapore Acute Kidney Injury score. The Singapore Acute Kidney Injury score is a simple way to predict, at the time of admission to the intensive care unit, an Asian patient's risk of developing acute kidney injury after coronary artery bypass surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Collateral circulation of the rat lower limb and its significance in ischemia-reperfusion studies.
Rosero, Olivér; Németh, Károly; Turóczi, Zsolt; Fülöp, András; Garbaisz, Dávid; Győrffy, András; Szuák, András; Dorogi, Bence; Kiss, Mátyás; Nemeskéri, Ágnes; Harsányi, László; Szijártó, Attila
2014-12-01
Rats are the most commonly used animal model for studies of acute lower limb ischemia-reperfusion. The ischemia induced by arterial clamping may cause milder damage than the application of a tourniquet if the presence of a possible collateral system is considered. Male Wistar rats were randomized into three groups: in group A, the muscle weight affected by ischemia was measured; in group B, the severity of muscle damage caused by the application of a tourniquet and by infrarenal aortic occlusion was examined. Blood and muscle samples were taken from group B to assess the serum necroenzyme, potassium and TNF-α levels, as well as the muscle fiber viability and for histological examinations. In group C, the identification of the lower limb collateral system was performed using corrosion casting. Tourniquet application affected the lower muscle mass and resulted in significantly more severe injury compared to infrarenal aortic occlusion. This difference was reflected in the serum necroenzyme, potassium and TNF-α levels. The histological examination and viability assay confirmed these findings. The corrosion casts showed several anastomoses capable of supplying the lower limb. Tourniquet application proved to be capable of inducing absolute lower limb ischemia, in contrast to infrarenal aortic ligation, where a rich collateral system is considered to help mitigate the injury.
Lozos, Vasileios A; Toumpoulis, Ioannis K; Agrogiannis, Georgios; Giamarellos-Bourboulis, Evangelos J; Chamogeorgakis, Themistocles P; Rizos, Ioannis K; Patsouris, Efstratios S; Anagnostopoulos, Constantine E; Rokkas, Chris K
2013-01-01
Potassium adenosine triphosphate (KATP) channel openers have been involved in the enhancement of ischemic tolerance in various tissues. The purpose of the present study is to evaluate the effects of aprikalim, a specific KATP channel opener, on spinal cord ischemic injury. Fifty-four rabbits were randomly assigned to three groups: group 1 (n = 18, sham operation), group 2 (n = 18, 30 min of normothermic aortic cross-clamping) and group 3 (n = 18, aprikalim 100 μg/kg was administered 15 min before 30 min of normothermic aortic cross-clamping). Neurologic evaluation was performed according to the modified Tarlov scale. Six animals from each group were sacrificed at 24, 48 and 168 h postoperatively. The lumbar spinal cords were harvested and examined histologically. The motor neurons were counted and the histologic lesions were scored (0-3, 3: normal). Group 3 (aprikalim group) had better Tarlov scores compared to group 2 at all-time points (P < 0.025). The histologic changes were proportional to the Tarlov scores and group 3 had better functional outcome as compared to group 2 at 168 h (number of neurons: 21.2 ± 4.9 vs. 8.0 ± 2.7, P < 0.001 and histologic score: 1.67 ± 1.03 vs. 0.50 ± 0.55, P = 0.03). Although aprikalim exhibited improved effect on clinical and histologic neurologic outcome when compared to normothermic spinal cord ischemia, animals in group 3 had worse Tarlov score, reduced number of motor neurons and worse histologic score when compared to group 1 (sham operation) at 168 h (P = 0.003, P = 0.001 and P = 0.019 respectively). Aprikalim reduces the severity of spinal cord ischemic injury in a rabbit model of spinal cord ischemia. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Regional wall mechanics and blunt traumatic aortic rupture at the isthmus.
Pearson, Richard; Philips, Nicholas; Hancock, Richard; Hashim, Sharul; Field, Mark; Richens, David; McNally, Donal
2008-09-01
Blunt traumatic aortic injury (BTAI) is part of a spectrum of diseases termed acute aortic syndrome that accounts for 20% of road traffic accident related deaths. The injury has a complex aetiology with a number of putative mechanisms accounting for the injury profile, characteristics of which include a transverse primary intimal tear located at the aortic isthmus. We hypothesised that an understanding of regional aortic wall mechanics would contribute to an understanding of the aetiology of BTAI. Samples of porcine aorta were prepared from ascending (A), descending (D) and peri-isthmus regions (I). A histological analysis of aortic wall architecture was performed at the site of attachment of the ligamentum arteriosum. Samples were mounted in a bubble inflation clamping rig, connected via a solenoid release valve to a compressed air reservoir. Using a pressure transducer and high-speed camera (1000fps) we collected data on wall thickness, rupture pressure and radial extension, allowing calculation of ultimate tensile stress. Histological analysis at the point of attachment of the ligamentum arteriosum to the isthmus shows some heterogeneity in cellular architecture extending deep into the tunica media. Wall thickness was significantly different between the three sampled regions (A>I>D, p<0.05). However, we found no difference in absolute rupture pressure between the three regions (kPa), (A, 300+/-28.9; I, 287+/-48.3; D, 321+/-29.6). Radial extension (cm) was significantly greater in A vs I (p<0.05), (A, 1.85+/-0.114; I, 1.66+/-0.109; D, 1.70+/-0.138). Ultimate tensile stress (kPa), (A, 3699+/-789; I, 3248+/-1430; D, 4260+/-1626) was significantly greater in D than I (p<0.05). The mechanism of blunt traumatic aortic rupture is not mechanically simple but must correspond to a complex combination of both relative motion of the structures within the thorax and local loading of the tissues, either as a result of their anatomy or due to the nature of the impact. A pressure spike alone is unlikely to be the primary cause of the peri-isthmus injury but may well be a contributory prerequisite.
Mongé, Michael C; Eltayeb, Osama; Costello, John M; Sarwark, Anne E; Carr, Michael R; Backer, Carl L
2015-07-01
Since 1989 all patients with anomalous origin of the left coronary artery from the pulmonary artery at our institution have been treated with aortic implantation. The purpose of this review was to assess the late outcomes of these patients, especially regarding left ventricular (LV) function and mitral valve insufficiency. Between 1989 and 2014, 36 patients had aortic implantation of anomalous origin of the left coronary artery from the pulmonary artery. Mean age at surgery was 2.5 ± 5.1 years (median, 0.5 years). Operative strategy included antegrade cold-blood cardioplegia, main pulmonary artery transection, aortic implantation with a large button of pulmonary artery, pulmonary reconstruction with fresh autologous pericardium, and prolonged postoperative inotropic and ventilator support. Mitral regurgitation and LV dysfunction were graded as 0 to 4 (0 = none, 1 = trivial, 1.5 = trivial-mild, 2 = mild, 2.5 = mild-moderate, 3 = moderate, 3.5 = moderate-severe, and 4 = severe). Mean mitral regurgitation grade preoperatively was 2.95 ± 0.95. Mean LV dysfunction grade was 3.14 ± 1.27. Mean cross-clamp and cardiopulmonary bypass times were 49.1 ± 18 minutes (median, 48.5 minutes) and 147.5 ± 45 minutes (median, 139 minutes), respectively. There was no operative or late mortality. Four patients had delayed sternal closure. Mean duration of ventilator support was 11 ± 6.6 days (median, 9 days). Two patients required 3 and 6 days of postoperative extracorporeal mechanical circulatory support. Mean length of stay was 25 ± 18 days (median, 19 days). No patient has required reoperation for supravalvar pulmonary stenosis, coronary stenosis, or mitral valve repair or replacement. Late echocardiographic follow-up shows a mean mitral regurgitation grade of 1.67 ± 1.05 and a mean LV dysfunction grade of 0.23 ± 0.68. Aortic implantation is our procedure of choice for patients with anomalous origin of the left coronary artery from the pulmonary artery. No patient required mitral valve repair or transplant. There was marked improvement of mitral regurgitation grade, return to essentially normal LV function, and no mortality during a 25-year period. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Total aortic arch replacement with the elephant trunk technique: single-centre 30-year results.
Shrestha, Malakh; Martens, Andreas; Krüger, Heike; Maeding, Illona; Ius, Fabio; Fleissner, Felix; Haverich, Axel
2014-02-01
The combined disease of the aortic arch and the descending aorta (aneurysms and dissection) remains a surgical challenge. Various approaches have been used to treat this complex pathology. In the two-stage operation, at the first-stage operation, the aortic arch is replaced through a median sternotomy. Later, at the second-stage operation, the descending thoracic aorta is replaced through a lateral thoracotomy. The elephant trunk (ET) technique was introduced by H.G. Borst at our centre in March 1982, greatly simplifying the second-phase operation. We present our 30-year experience. From March 1982 to March 2012, 179 patients (112 males, age 56.4±12.6 years) received an ET procedure for the combined disease of the aortic arch and the descending aorta (91 aneurysms, 88 dissections (47 acute)). Fifty-six of these patients had undergone previous cardiac operations. Concomitant procedures were performed if necessary. The cerebral protection was done either by deep (till 1999) or moderate hypothermic circulatory arrest and selective antegrade cerebral perfusion (SACP, after 1999). Cardiopulmonary bypass (CPB) and X-clamp times were 208.5±76.5 min and 123.7±54.8 min, respectively. The intraoperative mortality and 30-day mortality during the first-stage operation were 1.7% (3/179) and 17.3% (31/179, 15 with AADA), respectively. Perioperative stroke was 7.9% (n=14/176). Postoperative recurrent nerve palsy was present in 18.2% (32/176) and paraplegia in 5.6% (10/176). The second-stage completion operation was performed as early as possible. Fifty-seven second-stage completion procedures were performed, either surgically (n=50) or through interventional techniques (n=7). The intraoperative and 30-day mortality after the second-stage completion procedures were 5.2% (3/57) and 7.0% (4/57), respectively. The stroke, recurrent nerve palsy and paraplegia rates were 0, 0 and 7% (4/54), respectively. The ET technique has greatly facilitated the two-stage approach to the surgical treatment of combined diseases of the aortic arch and descending aorta. The initial learning curve, acute dissections, re-do and concomitant procedures partially explain the higher mortality rate. Despite the development of new hybrid techniques, there is still a role for the classical ET in selected patients, particularly in the context of proven long-term results and cost effectiveness.
Cardiovascular transition at birth: a physiological sequence.
Hooper, Stuart B; Te Pas, Arjan B; Lang, Justin; van Vonderen, Jeroen J; Roehr, Charles Christoph; Kluckow, Martin; Gill, Andrew W; Wallace, Euan M; Polglase, Graeme R
2015-05-01
The transition to newborn life at birth involves major cardiovascular changes that are triggered by lung aeration. These include a large increase in pulmonary blood flow (PBF), which is required for pulmonary gas exchange and to replace umbilical venous return as the source of preload for the left heart. Clamping the umbilical cord before PBF increases reduces venous return and preload for the left heart and thereby reduces cardiac output. Thus, if ventilation onset is delayed following cord clamping, the infant is at risk of superimposing an ischemic insult, due to low cardiac output, on top of an asphyxic insult. Much debate has centered on the timing of cord clamping at birth, focusing mainly on the potential for a time-dependent placental to infant blood transfusion. This has prompted recommendations for delayed cord clamping for a set time after birth in infants not requiring resuscitation. However, recent evidence indicates that ventilation onset before cord clamping mitigates the adverse cardiovascular consequences caused by immediate cord clamping. This indicates that the timing of cord clamping should be based on the infant's physiology rather than an arbitrary period of time and that delayed cord clamping may be of greatest benefit to apneic infants.
Safaei, Naser; Babaei, Hossein; Azarfarin, Rasoul; Jodati, Ahmad-Reza; Yaghoubi, Alireza; Sheikhalizadeh, Mohammad-Ali
2017-01-01
This study aimed to test the beneficial effect of grape seed extract (GSE) (Vitis vinifera) and Vitamin C in oxidative stress and reperfusion injury induced by cardiopulmonary bypass (CPB) in coronary artery bypass surgery. In this randomized trial, 87 patients undergoing elective and isolated coronary bypass surgery included. The patients were randomly assigned into three groups (n = 29 each): (1) Control group with no treatment, (2) GSE group who received the extract 24 h before operation, 100 mg every 6 h, orally, (3) Vitamin C group who received 25 mg/kg Vitamin C through CPB during surgery. Blood samples were taken from coronary sinus at (T1) just before aortic cross clamp; (T2) just before starting controlled aortic root reperfusion; and (T3) 10 min after root reperfusion. Some clinical parameters and biochemical markers were compared among the groups. There were significant differences in tracheal intubation times, sinus rhythm return, and left ventricular function between treatment groups compared with control (P < 0.05). Total antioxidant capacity was higher (P < 0.05) in both grape seed and Vitamin C groups at T2 and T3 times. In reperfusion period, malondialdehyde level was increased in control group; however, it was significantly lower for the grape seed group (P = 0.04). The differences in the mean levels of superoxide dismutase and glutathione peroxidase among the three groups were not significant (P > 0.05 in all cases). In our patients, GSE and Vitamin C had antioxidative effects and reduced deleterious effects of CPB during coronary artery bypass grafting surgery.
Correction of congenital heart defects in Jehovah's Witness children.
Alexi-Meskishvili, V; Stiller, B; Koster, A; Böttcher, W; Hübler, M; Photiadis, J; Lange, P E; Hetzer, R
2004-06-01
Between August 1989 and July 2003 14 Jehovah's Witness children with congenital heart defects (CHD) aged under 14 years (median 2.9 years) and with a median weight of 14 kg underwent 16 operations with cardiopulmonary bypass (CPB). Five children had been operated on previously between one to three times. Preoperatively, 7 children were prepared with oral iron supplementation and 10 received erythropoietin. Mean hemoglobin (Hb) at admission was 14.4 g/dl (range 10.9 - 19.2). The cardiopulmonary bypass (CPB) circuit was modified to reduce total priming volume. High doses of aprotinin were administered. The modified ultrafiltration (MUF) circuit, used in 7 patients, was parallel to the ECC circuit with continuous circulation of the blood through a small shunt between the arterial and venous lines. Operations performed consisted of VSD closure (3 pts.), ASD closure (3 pts.), Fontan operation (2 pts.), and complete AV canal correction, aortic commissurotomy, Ross operation, Glenn shunt, cor triatriatum correction, MV reconstruction combined with left outflow tract stenosis resection, correction of absent pulmonary valve syndrome, and correction of tetralogy of Fallot in one patient each. There were no deaths. Mean duration of CPB was 192 min and mean aortic cross-clamp time 40 min. The Hb value at the end of the operation was 4.9 - 14.5 g/dl (mean 9.6) and at discharge it was 7.1 - 14.5 g/dl (mean 15.5). No blood or blood products were used in any patient. Bloodless cardiac surgery with and without CPB can be safely performed in Jehovah's Witness infants and children.
Utility of a super-flexible three-dimensional printed heart model in congenital heart surgery.
Hoashi, Takaya; Ichikawa, Hajime; Nakata, Tomohiro; Shimada, Masatoshi; Ozawa, Hideto; Higashida, Akihiko; Kurosaki, Kenichi; Kanzaki, Suzu; Shiraishi, Isao
2018-05-28
The objective of this study was to assess the utility of 3D printed heart models of congenital heart disease for preoperative surgical simulation. Twenty patient-specific 3D models were created between March 2015 and August 2017. All operations were performed by a young consultant surgeon who had no prior experience with complex biventricular repair. All 15 patients with balanced ventricles had outflow tract malformations (double-outlet right ventricle in 7 patients, congenitally corrected transposition of great arteries in 5, transposition of great arteries in 1, interrupted aortic arch Type B in 1, tetralogy of Fallot with pulmonary atresia and major aortopulmonary collateral arteries in 1). One patient had hypoplastic left heart complex, and the remaining 4 patients had a functional single ventricle. The median age at operation was 1.4 (range 0.1-5.9) years. Based on a multislice computed tomography data set, the 3D models were made of polyurethane resins using stereolithography as the printing technology and vacuum casting as the manufacturing method. All but 4 patients with a functional single ventricle underwent complete biventricular repair. The median cardiopulmonary bypass time and aortic cross-clamp time were 345 (110-570) min and 114 (35-293) min, respectively. During the median follow-up period of 1.3 (0.1-2.5) years, no mortality was observed. None of the patients experienced surgical heart block or systemic ventricular outflow tract obstruction. Three-dimensional printed heart models showed potential utility, especially in understanding the relationship between intraventricular communications and great vessels, as well as in simulation for creating intracardiac pathways.
Clinical aspects of incorporating cord clamping into stabilisation of preterm infants.
Knol, Ronny; Brouwer, Emma; Vernooij, Alex S N; Klumper, Frans J C M; DeKoninck, Philip; Hooper, Stuart B; Te Pas, Arjan B
2018-04-21
Fetal to neonatal transition is characterised by major pulmonary and haemodynamic changes occurring in a short period of time. In the international neonatal resuscitation guidelines, comprehensive recommendations are available on supporting pulmonary transition and delaying clamping of the cord in preterm infants. Recent experimental studies demonstrated that the pulmonary and haemodynamic transition are intimately linked, could influence each other and that the timing of umbilical cord clamping should be incorporated into the respiratory stabilisation. We reviewed the current knowledge on how to incorporate cord clamping into stabilisation of preterm infants and the physiological-based cord clamping (PBCC) approach, with the infant's transitional status as key determinant of timing of cord clamping. This approach could result in optimal timing of cord clamping and has the potential to reduce major morbidities and mortality in preterm infants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Zheng, Yong; Gu, Qiang; Chen, Hong-Wu; Peng, Huai-Ming; Jia, Dong-Yu; Zhou, Yu; Xiang, Mei-Xiang
The relative preventative efficacy of amiodarone and lidocaine for ventricular fibrillation (VF) after release of an aortic cross-clamp (ACC) during open heart surgery has not been determined. This meta-analysis was designed to systematically evaluate the influence of amiodarone, lidocaine, or placebo on the incidence of VF after ACC. Prospective randomized controlled trials (RCTs) that compared the VF-preventative effects of amiodarone with lidocaine, or amiodarone or lidocaine with placebo were included. PubMed, EMBASE, and the Cochrane Library were searched for relevant RCTs. Fixed or randomized effect models were applied according to the heterogeneity of the data from the selected studies. We included eight RCTs in the analysis. Pooled results suggested that the preventative effects of amiodarone and lidocaine were comparable (relative risk (RR)=1.12, 95% confidence interval (CI): 0.70 to 1.80, P=0.63), but both were superior to the placebo (amiodarone, RR=0.71, 95% CI: 0.51 to 1.00, P=0.05; lidocaine, RR=0.63, 95% CI: 0.46 to 0.88, P=0.006). The percentage of patients requiring electric defibrillation counter shocks (DCSs) did not differ significantly among patients administered amiodarone (RR=0.21, 95% CI: 0.04 to 1.19, P=0.08), lidocaine (RR=2.44, 95% CI: 0.13 to 44.02, P=0.55), or the placebo (RR=0.56, 95% CI: 0.25 to 1.25, P=0.16). Amiodarone and lidocaine are comparably effective in preventing VF after ACC, but the percentage of patients who subsequently require DCSs does not differ among those administered amiodarone, lidocaine, or placebo.
Püschel, Anja; Ebel, Rasmus; Fuchs, Patricia; Hofmann, Janet; Schubert, Jochen K; Roesner, Jan P; Bergt, Stefan; Wree, Andreas; Vollmar, Brigitte; Klar, Ernst; Bünger, Carsten M; Kischkel, Sabine
2018-05-01
Paraplegia due to spinal cord ischemia (SCI) is a serious complication after repair of thoracoabdominal aortic aneurysms. For prevention and early treatment of spinal ischemia, intraoperative monitoring of spinal cord integrity is essential. This study was intended to improve recognition of SCI through a combination of transcranial motor-evoked potentials (tc-MEPs), serum markers, and innovative breath analysis. In 9 female German Landrace pigs, tc-MEPs were captured, markers of neuronal damage were determined in blood, and volatile organic compounds (VOCs) were analyzed in exhaled air. After thoraco-phrenico-laparotomy, SCI was initiated through sequential clamping (n = 4) or permanently ligating (n = 5) SAs of the abdominal and thoracic aorta in caudocranial orientation until a drop in the tc-MEPs to at least 25% of the baseline was recorded. VOCs in breath were determined by means of solid-phase microextraction coupled with gas chromatography-mass spectrometry. After waking up, clinical and neurological status was evaluated (Tarlov score). Spinal cord histology was obtained in postmortem. Permanent vessel ligature induced a worse neurological outcome and a higher number of necrotic motor neurons compared to clamping. Changes of serum markers remained unspecific. After laparotomy, exhaled acetone and isopropanol showed highest concentrations, and pentane and hexane increased during ischemia-reperfusion injury. To mimic spinal ischemia occurring in humans during aortic aneurysm repair, animal models have to be meticulously evaluated concerning vascular anatomy and function. Volatiles from breath indicated metabolic stress during surgery and oxidative damage through ischemia reperfusion. Breath VOCs may provide complimentary information to conventional monitoring methods. Copyright © 2018 Elsevier Inc. All rights reserved.
Direct Comparison of the Edwards Intuity Elite and Sorin Perceval S Rapid Deployment Aortic Valves.
Liakopoulos, Oliver J; Gerfer, Stephen; Weider, Simone; Rahmanian, Parwis; Zeriouh, Mohamed; Eghbalzadeh, Kaveh; Sabashnikov, Anton; Choi, Yeong-Hoon; Wippermann, Jens; Wahlers, Thorsten
2018-01-01
Rapid deployment aortic valve replacement (RDAVR) has emerged as an attractive alternative to conventional aortic valve replacement. This single-center study directly compared two commercially available rapid deployment valves with regard to clinical outcomes, valve-related complications, and hemodynamic performance. A total of consecutive 156 patients underwent RDAVR with the Intuity Elite (Edwards Lifesciences, Irvine, CA [Intuity group, n = 117] or the Perceval S (Sorin Group Italia Srl, Saluggia, Italy [Perceval group, n = 39]) between September 2012 and March 2016 at our institution. Perioperative data, including 30-day all-cause mortality, and echocardiographic measurements were assessed and retrospectively analyzed from our institutional database. Preoperative variables, including mean age (77 ± 5 years), European System for Cardiac Operative Risk Evaluation (6.8 ± 2.1), and body mass index (27 ± 5 kg/m 2 ), did not differ between groups. More male patients (60% versus 15%) with a higher body surface area (1.9 ± 0.2 m 2 versus 1.7 ± 0.2 m 2 ) and body weight (78 ± 13 kg versus 71 ± 15 kg) were in the Intuity group compared with the Perceval group, respectively (p < 0.05). Implanted RDAVR size (23.3 ± 1.8 mm versus 23.4 ± 1.5 mm), concomitant coronary artery bypass graft surgery (48% versus 33%), number of grafts, cardiopulmonary bypass, and aortic clamp time were comparable between the Intuity group and the Perceval group. Thirty-day mortality (Intuity 2.6% versus Perceval 5.1%) and valve-related complications (Intuity 12.0% versus Perceval 20.5%), including postoperative pacemaker implantation (Intuity 8.5% versus Perceval 12.8%), did not differ between groups. At discharge echocardiography, indexed effective orifice area was higher in the Intuity group, but peak or mean pressure gradients were comparable between groups. Performing RDAVR with the Intuity and Perceval rapid deployment valves provides comparable good clinical outcomes and valve hemodynamics, with low valve-related complication rates. The rate of pacemaker implantation was comparable for both rapid deployment valves, ranging from 8% to 13%. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Selective Arterial Clamping Versus Hilar Clamping for Minimally Invasive Partial Nephrectomy.
Yezdani, Mona; Yu, Sue-Jean; Lee, David I
2016-05-01
Partial nephrectomy has become an accepted treatment of cT1 renal masses as it provides improved long-term renal function compared to radical nephrectomy (Campbell et al. J Urol. 182:1271-9, 2009). Hilar clamping is utilized to help reduce bleeding and improve visibility during tumor resection. However, concern over risk of kidney injury with hilar clamping has led to new techniques to reduce length of warm ischemia time (WIT) during partial nephrectomy. These techniques have progressed over the years starting with early hilar unclamping, controlled hypotension during tumor resection, selective arterial clamping, minimal margin techniques, and off-clamp procedures. Selective arterial clamping has progressed significantly over the years. The main question is what are the exact short- and long-term renal effects from increasing clamp time. Moreover, does it make sense to perform these more time-consuming or more complex procedures if there is no long-term preservation of kidney function? More recent studies have shown no difference in renal function 6 months from surgery when selective arterial clamping or even hilar clamping is employed, although there is short-term improved decline in estimated glomerular filtration rate (eGFR) with selective clamping and off-clamp techniques (Komninos et al. BJU Int. 115:921-8, 2015; Shah et al. 117:293-9, 2015; Kallingal et al. BJU Int. doi: 10.1111/bju.13192, 2015). This paper reviews the progression of total hilar clamping to selective arterial clamping (SAC) and the possible difference its use makes on long-term renal function. SAC may be attempted based on surgeon's decision-making, but may be best used for more complex, larger, more central or hilar tumors and in patients who have renal insufficiency at baseline or a solitary kidney.
Abdullah, Newaj; Rahbar, Haider; Barod, Ravi; Dalela, Deepansh; Larson, Jeff; Johnson, Michael; Mass, Alon; Zargar, Homayoun; Kaouk, Jihad; Allaf, Mohamad; Bhayani, Sam; Stifelman, Michael; Rogers, Craig
2017-03-01
A Satinsky clamp may be a backup option for hilar clamping during robotic partial nephrectomy (RPN) if there are challenges with application of bulldog clamps, but there are potential safety concerns. We evaluate outcomes of RPN using Satinsky vs. bulldog clamps, and provide tips for safe use of the Satinsky as a backup option. Using a multi-center database, we identified 1073 patients who underwent RPN between 2006 and 2013, and had information available about method of hilar clamping (bulldog clamp vs. Satinsky clamp). Patient baseline characteristics, tumor features, and perioperative outcomes were compared between the Satinsky and bulldog clamp groups. A Satinsky clamp was used for hilar clamping in 94 (8.8 %) RPN cases, and bulldog clamps were used in 979 (91.2 %) cases. The use of a Satinsky clamp was associated with greater operative time (198 vs. 175 min, p < 0.001), estimated blood loss (EBL, 200 vs. 100 ml, p < 0.001), warm ischemia time (WIT, 20 vs. 19 min, p = 0.036), transfusion rate (12.8 vs. 4.8 %, p = 0.001), and hospital stay (3 vs. 2 days, p < 0.001). Tumor characteristics and number of renal vessels were similar between groups. There were six intraoperative complications in the Satinsky clamp group, but none were directly related to the Satinsky clamp. On multivariable analysis, the use of the Satinsky clamp was not associated with increase in intraoperative or Clavien ≥3 postoperative complications, positive surgical margin rate or percentage change in estimated glomerular filtration rate. A Satinsky clamp can be a backup option for hilar clamping during challenging RPN cases, but requires careful technique, and was rarely necessary.
Samson, Russell H; Lepore, Michael R; Showalter, David P; Nair, Deepak G; Lanoue, Julien B
2009-09-01
Left renal vein division and ligation (LRVDAL) is performed to facilitate complex abdominal aortic surgery. Surgeons restore continuity of the vein due to concern that ligation could cause renal compromise or hematuria. However, we report the short and long-term safety of left renal vein division and ligation. Between 1992 and 2007, we divided the left renal vein in 56 patients (40 males, 16 females) ages 57 to 84 (average 74-years-old) who were treated for aortic occlusive disease (9) or abdominal aortic aneurysm (47). Patients requiring concomitant renal artery reconstruction were excluded from this review. Suprarenal cross-clamp was used in 51 patients with temporary vessel-loop control of the renal arteries. Creatinine (Cr) and glomerular filtration rates (eGFR) were measured pre-, post-, and long-term after surgery. Outpatient records of all patients that had survived more than 12 months were also reviewed in order to evaluate the late effects on renal function or symptoms possibly related to LRVDAL. Median procedure duration was 157 (61-375) minutes. Median cross-clamp time was 16 (10-45) minutes. Median intensive care unit (ICU) and hospital length of stays were 2 (1-11) days and 7 (4-58) days, respectively. There were no deaths. There were no complications directly related to renal vein ligation. Hematuria, seen in 2 patients, was a result of traumatic insertion of a Foley catheter. Median pre-op and discharge Cr levels were 1.1 mg/dL (0.7-2.4 mg/dL) and 1.1 mg/dL (0.6-2.1 mg/dL), respectively (P < .5). Median change in Cr was 0.0 mg/dL and only increased in 14 patients (maximum increase 0.9 mg/dL). Median pre-op and discharge eGFR was 61 mL/minute (28-137 mL/minute/1.73 m2) and 67 mL/minute (32-138 mL/minute/1.73 m2), respectively (P < .5). Cr and eGFR in the 2 patients with a Cr of >2.0 mg/dL remained unchanged post-op. Only 2 patients with a Cr of <2.0 mg/dL had a post-op Cr >2.0 mg/dL and both returned to normal by day 3 post-op. Thirty-six patients have been followed for more than a year (median 34.5 months, maximum 144 months) and Cr has remained stable in all but 2 patients. These 2 patients, both with a pre-op Cr of 1.5 mg/dL, subsequently developed Cr levels of 2.1 mg/dL and 2.4 mg/dL but maintained baseline Cr levels for 25 and 34 months, respectively, before demonstrating these elevated levels which have proven to be unrelated to renal vein ligation. Hematuria and flank pain have never been recorded after discharge. Restoration of left renal vein continuity after LRVDAL may be unnecessary since renal compromise and hematuria was not encountered in this long-term analysis.
Matsuura, Kaoru; Mogi, Kenji; Sakurai, Manabu; Kawamura, Tomonori; Takahara, Yoshiharu
2013-09-01
This study aimed to assess the impact of aortic manipulation during off-pump coronary artery bypass (OPCAB) on neurological complications. Of 336 isolated OPCAB surgeries, the aorta was untouched in 264 cases (group A), whereas it was manipulated by a side-biting clamp in 72 (group B). The average follow-up was 2.9±2.5 years. One patient in each group developed postoperative stroke (P=0.38). The prevalence of triple-vessel disease (group A 40.9% vs. group B 61.1%; P=0.0003) and left main trunk disease (group A 30.7% vs. group B 47.2%; P=0.1) was lower in group A than in group B. The number of bypass grafts (group A 2.18±0.97 vs. group B 3.00±0.97; P=0.0001) was lower in group A than in group B. The prevalence of preoperative atrial fibrillation and the incidence of new-onset postoperative atrial fibrillation were not different between groups (P=0.74 and 0.86, respectively). Survival rate and freedom from major adverse cardiac events were not different between groups (P=0.87 and 0.51, respectively). However, freedom from neurological complications was significantly lower in group A (P=0.0006). The Cox hazard model showed that aortic manipulation (P=0.004; odds ratio, 6.18; 95% confidence interval, 1.8-21.6) and preoperative atrial fibrillation (P=0.001; odds ratio, 14.0; 95% confidence interval, 2.7-72.5) were risk factors for neurological complications. Although there was no difference in the incidence of immediate postoperative neurological complications, there were fewer medium-term neurological complications in OPCAB cases without aortic manipulation.
Allan, David S; Scrivens, Nicholas; Lawless, Tiffany; Mostert, Karen; Oppenheimer, Lawrence; Walker, Mark; Petraszko, Tanya; Elmoazzen, Heidi
2016-03-01
Public banking of umbilical cord blood units (CBUs) containing higher numbers of cells ensures timely engraftment after transplantation for increasing numbers of patients. Delayed clamping of the umbilical cord after birth may benefit some infants by preventing iron deficiency. Implications of delayed cord clamping for public cord blood banking remains unclear. CBUs collected by Canadian Blood Services at one collection site between November 1, 2014, and March 17, 2015, were analyzed. The delay in cord clamping after birth was timed and classified as "no delay," 20 to 60 seconds, more than 60 seconds, or more than 120 seconds. Of 367 collections, 100 reported no delay in clamping while clamping was delayed by 20 to 60 seconds (n = 69), more than 60 seconds (n = 98), or more than 120 seconds (n = 100) in the remaining cases. The mean volume and total nucleated cells (TNCs) in units with no delay in clamping were significantly greater than mean volumes for all categories of delayed clamping (Tukey's test, p < 0.05 for each comparison). The proportion of units with more than 1.5 × 10(9) TNCs was significantly reduced when clamping was delayed (p = 5.5 × 10(-8) ). The difference was most marked for cords that were clamped more than 120 seconds after delivery (6.2% compared with 39%). Delayed cord clamping greatly diminishes the volume and TNC count of units collected for a public cord blood bank. Creating an inventory of CBUs with high TNC content may take more time than expected. © 2015 AABB.
Incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery.
LaPietra, Angelo; Santana, Orlando; Mihos, Christos G; DeBeer, Steven; Rosen, Gerald P; Lamas, Gervasio A; Lamelas, Joseph
2014-07-01
Minimally invasive valve surgery has been associated with increased cerebrovascular complications. Our objective was to evaluate the incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery. We retrospectively reviewed all the minimally invasive valve surgery performed at our institution from January 2009 to June 2012. The operative times, lengths of stay, postoperative complications, and mortality were analyzed. A total of 1501 consecutive patients were identified. The mean age was 73 ± 13 years, and 808 patients (54%) were male. Of the 1501 patients, 206 (13.7%) had a history of a cerebrovascular accident, and 225 (15%) had undergone previous heart surgery. The procedures performed were 617 isolated aortic valve replacements (41.1%), 658 isolated mitral valve operations (43.8%), 6 tricuspid valve repairs (0.4%), 216 double valve surgery (14.4%), and 4 triple valve surgery (0.3%). Femoral cannulation was used in 1359 patients (90.5%) and central cannulation in 142 (9.5%). In 1392 patients (92.7%), the aorta was clamped, and in 109 (7.3%), the surgery was performed with the heart fibrillating. The median aortic crossclamp and cardiopulmonary bypass times were 86 minutes (interquartile range [IQR], 70-107) minutes and 116 minutes (IQR, 96-143), respectively. The median intensive care unit length of stay was 47 hours (IQR, 29-74), and the median postoperative hospital length of stay was 7 days (IQR, 5-10). A total of 23 cerebrovascular accidents (1.53%) and 38 deaths (2.53%) had occurred at 30 days postoperatively. Minimally invasive valve surgery was associated with an acceptable stroke rate, regardless of the cannulation technique. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Kanaoka, Yuji; Inagaki, Ei-ichirou; Hamanaka, Souhei; Masaki, Hisao; Tanemoto, Kazuo
2010-10-01
The transient systemic low perfusion that occurs during cardiovascular surgery leads to oxidative stress and the production of free radicals. A systemic increase of various markers of oxidative stress has been shown to occur during cardiopulmonary bypass (CPB). However, these markers have not been adequately evaluated because they seem to be reactive and short-lived. Here, oxidative stress was measured using the free radical analytical system (FRAS 4) assessing the derivatives of reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP). Blood samples were taken from 21 patients undergoing elective cardiovascular surgery. CPB was used in 15 patients, and abdominal aortic aneurysm (AAA) surgery without CPB was performed in 6. Measurements of d-ROMs and BAP were taken before surgery, 1 day, 1 week, and 2 weeks after surgery, and oxidative stress was evaluated. The d-ROM level increased gradually after cardiovascular surgery up to 2 weeks. Over time, the d-ROM level after surgery involving CPB became higher than that after AAA surgery. This difference reached statistical significance at 1 week and lasted to 2 weeks. The prolongation of CPB was prone to elevate the d-ROM level whereas the duration of the aortic clamp in AAA surgery had no relation to the d-ROM level. The BAP was also elevated after surgery, and was positively correlated with the level of d-ROMs. In this study, patients who underwent cardiovascular surgery involving CPB had significant oxidative damage. The production of ROMs was shown to depend on the duration of CPB. Damage can be reduced if CPB is avoided. When CPB must be used, shortening the CPB time may be effective in reducing oxidative stress.
Safaei, Naser; Babaei, Hossein; Azarfarin, Rasoul; Jodati, Ahmad-Reza; Yaghoubi, Alireza; Sheikhalizadeh, Mohammad-Ali
2017-01-01
Background: This study aimed to test the beneficial effect of grape seed extract (GSE) (Vitis vinifera) and Vitamin C in oxidative stress and reperfusion injury induced by cardiopulmonary bypass (CPB) in coronary artery bypass surgery. Patients and Methods: In this randomized trial, 87 patients undergoing elective and isolated coronary bypass surgery included. The patients were randomly assigned into three groups (n = 29 each): (1) Control group with no treatment, (2) GSE group who received the extract 24 h before operation, 100 mg every 6 h, orally, (3) Vitamin C group who received 25 mg/kg Vitamin C through CPB during surgery. Blood samples were taken from coronary sinus at (T1) just before aortic cross clamp; (T2) just before starting controlled aortic root reperfusion; and (T3) 10 min after root reperfusion. Some clinical parameters and biochemical markers were compared among the groups. Results: There were significant differences in tracheal intubation times, sinus rhythm return, and left ventricular function between treatment groups compared with control (P < 0.05). Total antioxidant capacity was higher (P < 0.05) in both grape seed and Vitamin C groups at T2 and T3 times. In reperfusion period, malondialdehyde level was increased in control group; however, it was significantly lower for the grape seed group (P = 0.04). The differences in the mean levels of superoxide dismutase and glutathione peroxidase among the three groups were not significant (P > 0.05 in all cases). Conclusions: In our patients, GSE and Vitamin C had antioxidative effects and reduced deleterious effects of CPB during coronary artery bypass grafting surgery. PMID:28074795
Umul, M; Cal, A C; Turna, B; Oktem, G; Aydın, H H
2016-01-01
To evaluate the effect of temporary complete hilar versus only renal artery clamping with different duration of warm ischemia on renal functions, and possibly identify a "safe" clamping type and duration of renal ischemia. Fifty male rabbits have been incorporated to study. Rabbits were subjected to ischemia/reperfusion injury by temporary vascular clamping. Reagents were randomized to 3 experimental groups (only renal artery clamping, complete hilar clamping, sham surgery) and sub-groups were determined according to different clamping times (30 and 60 minutes). Median laparotomy and left renal hilus dissection were performed to sham group. Only artery or complete hilar clamping was performed for 30 or 60 minutes by microvascular bulldog clamps to other reagents. Rabbits were sacrificed 10 days after primary surgery and left nephrectomy performed. Nephrectomy materials were evaluated for the level of nitric-oxide synthase (NOS) immunoreactivity, malondialdehyde (MDA) level and superoxide dismutase (SOD) activity and an electron microscopic examination was performed. NOS immunoreactivity was correlated with the temporary clamping time. We also observed that complete hilar vascular clamping entails an increase on NOS immunoreactivity. MDA levels were similar for all experimental surgery groups (p = 0.42). The SOD activity was decreased among all subgroups compared with sham surgery. But the significant decrease occurred in 30 minutes only artery and 30 minutes complete hilar clamping groups in proportion to sham surgery (p = 0.026 and p = 0.019, respectively). This current study suggested that only renal artery clamping under 30 minutes is more appropriate during renal surgical procedures requiring temporary vascular clamping.
Aortic stiffness and the balance between cardiac oxygen supply and demand: the Rotterdam Study.
Guelen, Ilja; Mattace-Raso, Francesco Us; van Popele, Nicole M; Westerhof, Berend E; Hofman, Albert; Witteman, Jacqueline Cm; Bos, Willem Jan W
2008-06-01
Aortic stiffness is an independent predictor of cardiovascular morbidity and mortality. We investigated whether aortic stiffness, estimated as aortic pulse wave velocity, is associated with decreased perfusion pressure estimated as the cardiac oxygen supply potential. Aortic stiffness and aortic pressure waves, reconstructed from finger blood pressure waves, were obtained in 2490 older adults within the framework of the Rotterdam Study, a large population-based study. Cardiac oxygen supply and demand were estimated using pulse wave analysis techniques, and related to aortic stiffness by linear regression analyses after adjustment for age, sex, mean arterial pressure and heart rate. Cardiac oxygen demand, estimated as the Systolic Pressure Time Index and the Rate Pressure Product, increased with increasing aortic stiffness [0.27 mmHg s (95% confidence interval: 0.21; 0.34)] and [42.2 mmHg/min (95% confidence interval: 34.1; 50.3)], respectively. Cardiac oxygen supply potential estimated as the Diastolic Pressure Time Index decreased [-0.70 mmHg s (95% confidence interval: -0.86; -0.54)] with aortic stiffening. Accordingly, the supply/demand ratio Diastolic Pressure Time Index/Systolic Pressure Time Index -1.11 (95% confidence interval: -0.14; -0.009) decreased with increasing aortic stiffness. Aortic stiffness is associated with estimates of increased cardiac oxygen demand and a decreased cardiac oxygen supply potential. These results may offer additional explanation for the relation between aortic stiffness and cardiovascular morbidity and mortality.
Solutions for transients in arbitrarily branching cables: III. Voltage clamp problems.
Major, G
1993-07-01
Branched cable voltage recording and voltage clamp analytical solutions derived in two previous papers are used to explore practical issues concerning voltage clamp. Single exponentials can be fitted reasonably well to the decay phase of clamped synaptic currents, although they contain many underlying components. The effective time constant depends on the fit interval. The smoothing effects on synaptic clamp currents of dendritic cables and series resistance are explored with a single cylinder + soma model, for inputs with different time courses. "Soma" and "cable" charging currents cannot be separated easily when the soma is much smaller than the dendrites. Subtractive soma capacitance compensation and series resistance compensation are discussed. In a hippocampal CA1 pyramidal neurone model, voltage control at most dendritic sites is extremely poor. Parameter dependencies are illustrated. The effects of series resistance compound those of dendritic cables and depend on the "effective capacitance" of the cell. Plausible combinations of parameters can cause order-of-magnitude distortions to clamp current waveform measures of simulated Schaeffer collateral inputs. These voltage clamp problems are unlikely to be solved by the use of switch clamp methods.
Hu, Zhiyong; Xu, Lili; Zhu, Zhirui; Seal, Robert; McQuillan, Patrick M.
2016-01-01
Abstract The objective of this study was to evaluate the effect of hypothermic cardiopulmonary bypass (CPB) on cerebral oxygen saturation (rSO2), internal jugular bulb venous oxygen saturation (SjvO2), mixed venous oxygen saturation (SvO2), and bispectral index (BIS) used to monitor cerebral oxygen balance in pediatric patients. Sixty American Society of Anesthesiologists Class II-III patients aged 1 to 4 years old with congenital heart disease scheduled for elective cardiac surgery were included in this study. Temperature, BIS, rSO2, mean arterial pressure, central venous pressure, cerebral perfusion pressure (CPP), and hematocrit were recorded. Internal jugular bulb venous oxygen saturation and SvO2 were obtained from blood gas analysis at the time points: after induction of anesthesia (T0), beginning of CPB (T1), ascending aortic occlusion (T2), 20 minutes after initiating CPB (T3), coronary reperfusion (T4), separation from CPB (T5), and at the end of operation (T6). The effect of hypothermia or changes in CPP on rSO2, SjvO2, SvO2, and BIS were analyzed. Compared with postinduction baseline values, rSO2 significantly decreased at all-time points: onset of extracorporeal circulation, ascending aortic occlusion, 20 minutes after CPB initiation, coronary reperfusion, and separation from CPB (P < 0.05). Compared with measurements made following induction of anesthesia, SjvO2 significantly increased with initiation of CPB, ascending aortic occlusion, 20 minutes after initiating CPB, coronary reperfusion, and separation from CPB (P < 0.05). Compared with induction of anesthesia, BIS significantly decreased with the onset of CPB, aortic cross clamping, 20 minutes after initiating CPB, and coronary reperfusion (P < 0.05). Bispectral index increased following separation from CPB. There was no significant change in SvO2 during cardiopulmonary bypass (P > 0.05). Correlation analysis demonstrated that rSO2 was positively related to CPP (r = 0.687, P = 0.000), with a low linear correlation to temperature (r = 0.453, P = 0.000). Internal jugular bulb venous oxygen saturation was negatively related to temperature (r = −0.689, P = 0.000). Bispectral index was positively related to both temperature (r = 0.824, P = 0.000) and CPP (r = 0.782, P = 0.000). Cerebral oxygen saturation had a positive linear correlation with CPP and a low linear correlation to temperature. Internal jugular bulb venous oxygen saturation had a negative linear correlation to temperature. Pre-and and early postbypass periods are vulnerable times for adequate cerebral oxygenation. Anesthetic management must aim to optimize the supply and demand relationship. PMID:26765454
Hu, Zhiyong; Xu, Lili; Zhu, Zhirui; Seal, Robert; McQuillan, Patrick M
2016-01-01
The objective of this study was to evaluate the effect of hypothermic cardiopulmonary bypass (CPB) on cerebral oxygen saturation (rSO2), internal jugular bulb venous oxygen saturation (SjvO2), mixed venous oxygen saturation (SvO2), and bispectral index (BIS) used to monitor cerebral oxygen balance in pediatric patients.Sixty American Society of Anesthesiologists Class II-III patients aged 1 to 4 years old with congenital heart disease scheduled for elective cardiac surgery were included in this study. Temperature, BIS, rSO2, mean arterial pressure, central venous pressure, cerebral perfusion pressure (CPP), and hematocrit were recorded. Internal jugular bulb venous oxygen saturation and SvO2 were obtained from blood gas analysis at the time points: after induction of anesthesia (T0), beginning of CPB (T1), ascending aortic occlusion (T2), 20 minutes after initiating CPB (T3), coronary reperfusion (T4), separation from CPB (T5), and at the end of operation (T6). The effect of hypothermia or changes in CPP on rSO2, SjvO2, SvO2, and BIS were analyzed.Compared with postinduction baseline values, rSO2 significantly decreased at all-time points: onset of extracorporeal circulation, ascending aortic occlusion, 20 minutes after CPB initiation, coronary reperfusion, and separation from CPB (P < 0.05). Compared with measurements made following induction of anesthesia, SjvO2 significantly increased with initiation of CPB, ascending aortic occlusion, 20 minutes after initiating CPB, coronary reperfusion, and separation from CPB (P < 0.05). Compared with induction of anesthesia, BIS significantly decreased with the onset of CPB, aortic cross clamping, 20 minutes after initiating CPB, and coronary reperfusion (P < 0.05). Bispectral index increased following separation from CPB. There was no significant change in SvO2 during cardiopulmonary bypass (P > 0.05). Correlation analysis demonstrated that rSO2 was positively related to CPP (r = 0.687, P = 0.000), with a low linear correlation to temperature (r = 0.453, P = 0.000). Internal jugular bulb venous oxygen saturation was negatively related to temperature (r = -0.689, P = 0.000). Bispectral index was positively related to both temperature (r = 0.824, P = 0.000) and CPP (r = 0.782, P = 0.000). Cerebral oxygen saturation had a positive linear correlation with CPP and a low linear correlation to temperature. Internal jugular bulb venous oxygen saturation had a negative linear correlation to temperature.Pre-and and early postbypass periods are vulnerable times for adequate cerebral oxygenation. Anesthetic management must aim to optimize the supply and demand relationship.
Bi, Sheng; Xia, Ming
2015-08-11
To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.
Hemostatic Modifications of the Bentall Procedure
Della Corte, Alessandro; Baldascino, Francesco; La Marca, Francesca; Scardone, Michelangelo; Nappi, Gianantonio; Cefarelli, Mariano; De Santo, Luca S.; Pepino, Paolo; Cotrufo, Maurizio; De Feo, Marisa
2012-01-01
Bleeding is an important predictor of morbidity and mortality rates after the Bentall operation. This study reports our recent experience with composite aortic root replacement via a slightly modified button-Bentall operation. Fifty-six consecutive patients underwent a Bentall operation on an elective basis from January 2008 through December 2009. In all cases, we used 2 modifications: we imbricated the pledgeted 2-0 polyester interrupted U stitches of the proximal suture line, and at that same suture line we sealed with fibrin glue the possible sources of oozing. The series featured high proportions of associated procedures (25%) and reoperations (23%). The mean cardiopulmonary bypass and aortic cross-clamp times were 166 ± 50 and 113 ± 27 min, respectively. No case of operative or hospital (30-day) death was observed. Postoperative drainage amounted to 705 mL (median) on the first postoperative day and 377 mL (mean) on the second. Surgical re-exploration for bleeding was needed in only 1 patient (1.8%). Postoperative acute kidney injury was observed in 5 patients, neurologic complications in 3, and respiratory insufficiency requiring prolonged mechanical ventilation in another 3. Both respiratory and renal complications were significantly associated with greater consumption of blood products (P=0.03 and P=0.001, respectively). We conclude that the combined use of imbricated proximal suture-line stitches and subsequent fibrin-sealant spraying were associated with no deaths and with low rates of bleeding and other adverse postoperative sequelae in our 2-year experience with the Bentall operation in an elective series of patients characterized by a difficult mixture of prognoses. PMID:22740732
Minimally invasive redo mitral valve surgery without aortic crossclamp.
Milani, Rodrigo; Brofman, Paulo Roberto Slud; Oliveira, Sergio; Patrial Neto, Luiz; Rosa, Matheus; Lima, Victor Hugo; Binder, Luis Fernando; Sanches, Aline
2013-01-01
Reoperations of the mitral valve have a higher rate of complications when compared with the first surgery. With the field of video-assisted techniques for the first surgery of mitral valve became routine, reoperation cases began to arouse interest for this less invasive procedures. To assess the results and the technical difficulties in 10 patients undergoing minimally invasive redo mitral valve surgery. Cardiopulmonary bypass was installed through a cannula placed in the femoral vessels and right internal jugular vein, conducted in 28 degrees of temperature in ventricular fibrillation. A right lateral thoracotomy with 5 to 6 cm in the third or fourth intercostal space was done, pericardium was displaced only at the point of atriotomy. The aorta was not clamped. Ten patients with mean age of 56.9 ± 10.5 years, four were in atrial fibrilation rhythm and six in sinusal. Average time between first operation and reoperations was 11 ± 3.43 years. The mean EuroSCORE group was 8.3 ± 1.82. The mean ventricular fibrillation and cardiopulmonary bypass was respectively 70.9 ± 17.66 min and 109.4 ± 25.37 min. The average length of stay was 7.6 ± 1.5 days. There were no deaths in this series. Mitral valve reoperation can be performed through less invasive techniques with good immediate results, low morbidity and mortality. However, this type of surgery requires a longer duration of cardiopulmonary bypass, especially in cases where the patient already has prosthesis. The presence of a minimal aortic insufficiency also makes this procedure technically more challenging.
Aljalloud, Ali; Shoaib, Mohamed; Egron, Sandrine; Arias, Jessica; Tewarie, Lachmandath; Schnoering, Heike; Lotfi, Shahram; Goetzenich, Andreas; Hatam, Nima; Pott, Desiree; Zhong, Zhaoyang; Steinseifer, Ulrich; Zayat, Rachad; Autschbach, Ruediger
2018-05-17
Sutureless aortic valve prostheses are gaining popularity due to the substantial reduction in cross-clamp time. In this study, we report our observations on the cusp-fluttering phenomenon of the Perceval bioprosthesis (LivaNova, London, UK) using a combination of technical and medical perspectives. Between August 2014 and December 2016, a total of 108 patients (69% women) with a mean age of 78 years had aortic valve replacement using the Perceval bioprosthesis (34 combined procedures). All patients underwent transoesophageal echocardiography (TOE) intraoperatively. TOE was performed postoperatively to detect paravalvular leakage and to measure gradients, acceleration time, Doppler velocity indices (Vmax and LVOT/Vmax AV) and effective orifice area indices. In addition, a TOE examination was performed in 21 patients postoperatively. Data were collected retrospectively from our hospital database. The retrospective evaluation of the intraoperative TOE examinations revealed consistent fluttering in all patients with the Perceval bioprosthesis. The echocardiographic postoperative measurements showed a mean effective orifice area index of 0.91 ± 0.12 cm2/m2. The overall mean pressure and peak pressure gradients were in a higher range (13.5 ± 5.1 mmHg and 25.5 ± 8.6 mmHg, respectively), whereas acceleration time (62.8 ± 16.4 ms) and Doppler velocity indices (0.43 ± 0.11) were within the normal range according to the American Society of Echocardiography or european association of echocardiography (EAE) guidelines. The 2-dimensional TOE in Motion Mode (M-Mode) that was performed in patients with elevated lactate dehydrogenase (LDH) levels revealed remarkable fluttering of the cusps of the Perceval bioprosthesis. In our study cohort, we observed the fluttering phenomenon in all patients who received the Perceval bioprosthesis, which was correlated with elevated LDH levels and higher pressure gradients.
Valero, Marta Sofía; Oliván-Viguera, Aida; Garrido, Irene; Langa, Elisa; Berzosa, César; López, Víctor; Gómez-Rincón, Carlota; Murillo, María Divina; Köhler, Ralf
2015-12-01
In traditional herbal medicine, Rock Tea (Jasonia glutinosa) is known for its prophylactic and therapeutic value in various disorders including arterial hypertension. However, the mechanism by which Rock Tea exerts blood pressure-lowering actions has not been elucidated yet. Our aim was to demonstrate vasorelaxing effects of Rock Tea extract and to reveal its possible action mechanism. Isometric myography was conducted on high-K+-precontracted rings from rat thoracic aorta and tested extracts at concentrations of 0.5-5 mg/ml. Whole-cell patch-clamp experiments were performed in rat aortic vascular smooth muscle cells (line A7r5) to determine blocking effects on L-type Ca(2+) channels. Rock Tea extract relaxed the aorta contracted by high [K+] concentration dependently with an EC50 of ≈2.4 mg/ml and produced ≈75 % relaxation at the highest concentration tested. The L-type Ca(2+) channel blocker, verapamil (10(-6) M), had similar effects. Rock Tea extract had no effect in nominally Ca(2+)-free high-K(+) buffer but significantly inhibited contractions to re-addition of Ca(2+). Rock Tea extract inhibited the contractions induced by the L-type Ca(2+) channel activator Bay K 8644 (10(-5) M) and by phenylephrine (10(-6) M). Rock Tea extract and Y-27632 (10(-6) M), Rho-kinase inhibitor, had similar effects and the respective effects were not additive. Patch-clamp experiments demonstrated that Rock Tea extract (2.5 mg/ml) virtually abolished L-type Ca(2+) currents in A7r5. We conclude that Rock Tea extract produced vasorelaxation of rat aorta and that this relaxant effect is mediated by inhibition of L-type Ca(2+) channels. Rock Tea extracts may be of phytomedicinal value for prevention and adjuvant treatment of hypertension and other cardiovascular diseases.
Krzysztof, Szwed; Wojciech, Pawliszak; Zbigniew, Serafin; Mariusz, Kowalewski; Remigiusz, Tomczyk; Damian, Perlinski; Magdalena, Szwed; Marta, Tomaszewska; Lech, Anisimowicz; Alina, Borkowska
2017-07-10
Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. NCT03074604; Pre-results. 10-Mar-2017 Original. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Minich, L L; Tani, L Y; Pantalos, G M; Bolland, B L; Knorr, B K; Hawkins, J A
1998-11-01
Pediatric intraaortic balloon pumping (IABP) has met with little success because of technical difficulty in tracking rapid heart rates. This study was designed to evaluate the efficacy of M-mode echocardiography for IABP timing in a neonatal piglet model. Two groups of piglets underwent mitral valve avulsion to create a model of shock. Group 1 (n = 8; mean weight, 7.7+/-1.8 kg) underwent IABP timed with both the ascending aortic pressure and M-mode echocardiogram. Group 2 (n = 6; mean weight, 7.5+/-1.4 kg) underwent two separate periods of IABP: one with echocardiographic timing and the second using standard timing points from the femoral arterial pressure tracing and electrocardiogram. Measurements included ascending aortic flow, left anterior descending arterial flow, ascending aortic pressure, left atrial pressure, and heart rate. Mitral valve avulsion produced a shock model with a significant decrease in mean aortic pressure and aortic flow and a significant increase in left atrial pressure and heart rate. Compared with the shock state, IABP in group 1 animals resulted in a significant increase in aortic flow (353+/-152 versus 454+/-109 mL/min; p < 0.05) and a significant decrease in left atrial pressure (23+/-6 versus 17+/-7 mm Hg; p < 0.05). Group 2 animals with echocardiogram-timed IABP had significantly increased aortic flow (365+/-106 versus 458+/-107 mL/min; p < 0.05) and mean aortic pressure (43+/-11 versus 52+/-8 mm Hg; p < 0.05). However, standard-timed IABP failed to show any improvement. In piglets with rapid heart rates, echocardiogram-timed IABP results in increased aortic flow and pressure and decreased left atrial pressure compared with standard-timed IABP.
Imantalab, Vali; Mirmansouri, Ali; Mohammadzadeh Jouryabi, Ali; Naderi Nabi, Bahram; Kanani, Gholamreza; Nassiri Sheikhani, Nassir; Atrkarroushan, Zahra; Ghazanfar Tehran, Samaneh; Samadpour, Nastaran
2017-10-01
Postoperative pain is a complex process commonly caused by surgical trauma. It is one of the major concerns of patients undergoing heart surgery. Despite new techniques and modern analgesic treatments, postoperative pain is still one of the most important controversial issues. 68 patients scheduled for elective CABG with CPB were included in a prospective, double-blind clinical trial. They were randomly divided into two groups. One group received PCA pump including morphine (group P) with underlying infusion of 0.02 mg/kg/Qh, bolus dose of 1 mg, lockout time of 15 minutes, and a maximum of 4 bolus of 0.02 mg/kg for one hour and the other group received morphine bolus (group B). Three patients were excluded from the study, and 33 and 32 patients participated in the groups P and B, respectively. Variables including age, gender, pump time, aortic clamp time, duration of surgery, complications (nausea and vomiting, GI Bleeding, and hypoxia), level of pain based on VAS, opioid consumption, hemodynamic, and sedation status were measured in both groups. There was no significant difference between the groups regarding age, gender, pump time, clamp time, duration of surgery, complication, sedation score, and hemodynamic status in most of the assessment periods. By assessing the pain severity in the groups at different periods, results showed a significant difference between the groups except at enrollment, and a lower severity of pain was noted in the group P compared to the group B. The consumed opioid was significantly higher in the group P than in the group B. However, higher doses of diclofenac and paracetamol were administered in the group B compared to the group P. Results showed that higher morphine would be used in patients with PCA pump after extubation following heart surgery, and this increased dose of opioid was associated with better pain control and lack of complication. Therefore, PCA pump with underlying infusion could be effectively used in patients undergoing CABG that are directly assessed in intensive care unite.
Imantalab, Vali; Mirmansouri, Ali; Mohammadzadeh Jouryabi, Ali; Naderi Nabi, Bahram; Kanani, Gholamreza; Nassiri Sheikhani, Nassir; Atrkarroushan, Zahra; Ghazanfar Tehran, Samaneh; Samadpour, Nastaran
2017-01-01
Background Postoperative pain is a complex process commonly caused by surgical trauma. It is one of the major concerns of patients undergoing heart surgery. Despite new techniques and modern analgesic treatments, postoperative pain is still one of the most important controversial issues. Methods 68 patients scheduled for elective CABG with CPB were included in a prospective, double-blind clinical trial. They were randomly divided into two groups. One group received PCA pump including morphine (group P) with underlying infusion of 0.02 mg/kg/Qh, bolus dose of 1 mg, lockout time of 15 minutes, and a maximum of 4 bolus of 0.02 mg/kg for one hour and the other group received morphine bolus (group B). Three patients were excluded from the study, and 33 and 32 patients participated in the groups P and B, respectively. Variables including age, gender, pump time, aortic clamp time, duration of surgery, complications (nausea and vomiting, GI Bleeding, and hypoxia), level of pain based on VAS, opioid consumption, hemodynamic, and sedation status were measured in both groups. Results There was no significant difference between the groups regarding age, gender, pump time, clamp time, duration of surgery, complication, sedation score, and hemodynamic status in most of the assessment periods. By assessing the pain severity in the groups at different periods, results showed a significant difference between the groups except at enrollment, and a lower severity of pain was noted in the group P compared to the group B. The consumed opioid was significantly higher in the group P than in the group B. However, higher doses of diclofenac and paracetamol were administered in the group B compared to the group P. Conclusions Results showed that higher morphine would be used in patients with PCA pump after extubation following heart surgery, and this increased dose of opioid was associated with better pain control and lack of complication. Therefore, PCA pump with underlying infusion could be effectively used in patients undergoing CABG that are directly assessed in intensive care unite. PMID:29696108
Liver transplantation using elderly donors: a risk factor analysis.
Kim, Dae Y; Moon, Jang; Island, Eddie R; Tekin, Akin; Ganz, Susan; Levi, David; Selvaggi, Gennaro; Nishida, Seigo; Tzakis, Andreas G
2011-01-01
Survival after liver transplantation is negatively impacted by use of elderly deceased donors, but excluding them would increase waiting times and waiting list mortality. We reviewed our experience with liver transplantation (LT) utilizing livers from deceased donors 65 yr of age and older to identify those factors that impact graft survival. All adult patients (≥ 18 yr old) who underwent primary LT using deceased donor livers from donors aged ≥ 65 yr between February 1995 and November 2003 were included. With multivariate analysis we found four unfavorable characteristics significantly associated with higher post-transplant graft failure rate. These characteristics are hepatitis C as an etiology of liver disease, Model for End-Stage Liver Disease score >20, serum glucose level of donor > 200 mg/dL at the time of liver recovery, and skin incision to aortic cross-clamp time > 40 minutes in the donor surgery. The five-yr estimated graft survival rates having 0, 1, 2, 3, and 4 unfavorable characteristics were 100%, 82.0%, 81.7%, 39.3%, and 25.0%, respectively (p < 0.05). Our data demonstrated good graft survival can be achieved in LT using elderly donor liver allografts with appropriate patient selection, donor blood glucose management and efficient liver recovery with minimal manipulation of the liver during donor surgery. © 2010 John Wiley & Sons A/S.
Timing of umbilical cord-clamping and infant anaemia: the role of maternal anaemia.
Blouin, Brittany; Penny, Mary E; Maheu-Giroux, Mathieu; Casapía, Martín; Aguilar, Eder; Silva, Hermánn; Creed-Kanashiro, Hilary M; Joseph, Serene A; Gagnon, Anita; Rahme, Elham; Gyorkos, Theresa W
2013-05-01
Evidence from randomized controlled trials has shown that delayed cord-clamping is beneficial to infant iron status. The role of maternal anaemia in this relationship, however, has not been established. To determine the effect of maternal anaemia at delivery on the association between timing of umbilical cord-clamping and infant anaemia at 4 and 8 months of age. A cohort of pregnant women admitted to the labour room of Hospital Iquitos (Iquitos, Peru) and their newborns were recruited into the study during two time periods (18 May to 3 June and 6-20 July 2009). Between the two recruitment periods, the hospital's policy changed from early to delayed umbilical cord-clamping. Maternal haemoglobin levels were measured before delivery, and the time between delivery and cord-clamping was recorded at delivery for the entire cohort. Mother-infant pairs were followed-up at 4 (n = 207) and 8 months (n = 184) post partum. Infant haemoglobin levels were measured at follow-up visits. Data were analysed using logistic regression models. The prevalence of maternal anaemia (Hb <11.0 g/dl) at delivery was 22%. Infant haemoglobin levels at 4 and 8 months of age were 10.4 g/dl and 10.3 g/dl, respectively. Infant haemoglobin levels did not differ significantly between infants born to anaemic mothers and those born to non-anaemic mothers at either 4 or 8 months of age. However, the association between the timing of cord-clamping and infant anaemia was modified by the mother's anaemia status. Significant benefits of delayed cord-clamping in preventing anaemia were found in infants born to anaemic mothers at both 4 months (aOR = 0.59, 95% CI 0.36-0.99) and 8 months (aOR = 0.38, 95% CI 0.19-0.76) of age. The study contributes additional evidence in support of delayed cord-clamping. This intervention is likely to have most public health impact in areas with a high prevalence of anaemia during pregnancy.
Trojan, Michael; Rengier, Fabian; Kotelis, Drosos; Müller-Eschner, Matthias; Partovi, Sasan; Fink, Christian; Karmonik, Christof; Böckler, Dittmar; Kauczor, Hans-Ulrich; von Tengg-Kobligk, Hendrik
2017-01-01
To prospectively evaluate our hypothesis that three-dimensional time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA) is able to detect hemodynamic alterations in patients with chronic expanding aortic dissection compared to stable aortic dissections. 20 patients with chronic or residual aortic dissection in the descending aorta and patent false lumen underwent TR-MRA of the aorta at 1.5 T and repeated follow-up imaging (mean follow-up 5.4 years). 7 patients showed chronic aortic expansion and 13 patients had stable aortic diameters. Regions of interest were placed in the nondissected ascending aorta and the false lumen of the descending aorta at the level of the diaphragm (FL-diaphragm level) resulting in respective time-intensity curves. For the FL-diaphragm level, time-to-peak intensity and full width at half maximum were significantly shorter in the expansion group compared to the stable group ( p = 0.027 and p = 0.003), and upward and downward slopes of time-intensity curves were significantly steeper ( p = 0.015 and p = 0.005). The delay of peak intensity in the FL-diaphragm level compared to the nondissected ascending aorta was significantly shorter in the expansion group compared to the stable group ( p = 0.01). 3D TR-MRA detects significant alterations of hemodynamics within the patent false lumen of chronic expanding aortic dissections compared to stable aortic dissections.
The Aachen miniaturized heart-lung machine--first results in a small animal model.
Schnoering, Heike; Arens, Jutta; Sachweh, Joerg S; Veerman, Melanie; Tolba, Rene; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Vazquez-Jimenez, Jaime F
2009-11-01
Congenital heart surgery most often incorporates extracorporeal circulation. Due to foreign surface contact and the administration of foreign blood in many children, inflammatory response and hemolysis are important matters of debate. This is particularly an issue in premature and low birth-weight newborns. Taking these considerations into account, the Aachen miniaturized heart-lung machine (MiniHLM) with a total static priming volume of 102 mL (including tubing) was developed and tested in a small animal model. Fourteen female Chinchilla Bastard rabbits were operated on using two different kinds of circuits. In eight animals, a conventional HLM with Dideco Kids oxygenator and Stöckert roller pump (Sorin group, Milan, Italy) was used, and the Aachen MiniHLM was employed in six animals. Outcome parameters were hemolysis and blood gas analysis including lactate. The rabbits were anesthetized, and a standard median sternotomy was performed. The ascending aorta and the right atrium were cannulated. After initiating cardiopulmonary bypass, the aorta was cross-clamped, and cardiac arrest was induced by blood cardioplegia. Blood samples for hemolysis and blood gas analysis were drawn before, during, and after cardiopulmonary bypass. After 1 h aortic clamp time, all animals were weaned from cardiopulmonary bypass. Blood gas analysis revealed adequate oxygenation and perfusion during cardiopulmonary bypass, irrespective of the employed perfusion system. The use of the Aachen MiniHLM resulted in a statistically significant reduced decrease in fibrinogen during cardiopulmonary bypass. A trend revealing a reduced increase in free hemoglobin during bypass in the MiniHLM group could also be observed. This newly developed Aachen MiniHLM with low priming volume, reduced hemolysis, and excellent gas transfer (O(2) and CO(2)) may reduce circuit-induced complications during heart surgery in neonates.
Effects of Imperfect Dynamic Clamp: Computational and Experimental Results
Bettencourt, Jonathan C.; Lillis, Kyle P.; White, John A.
2008-01-01
In the dynamic clamp technique, a typically nonlinear feedback system delivers electrical current to an excitable cell that represents the actions of “virtual” ion channels (e.g., channels that are gated by local membrane potential or by electrical activity in neighboring biological or virtual neurons). Since the conception of this technique, there have been a number of different implementations of dynamic clamp systems, each with differing levels of flexibility and performance. Embedded hardware-based systems typically offer feedback that is very fast and precisely timed, but these systems are often expensive and sometimes inflexible. PC-based systems, on the other hand, allow the user to write software that defines an arbitrarily complex feedback system, but real-time performance in PC-based systems can be deteriorated by imperfect real-time performance. Here we systematically evaluate the performance requirements for artificial dynamic clamp knock-in of transient sodium and delayed rectifier potassium conductances. Specifically we examine the effects of controller time step duration, differential equation integration method, jitter (variability in time step), and latency (the time lag from reading inputs to updating outputs). Each of these control system flaws is artificially introduced in both simulated and real dynamic clamp experiments. We demonstrate that each of these errors affect dynamic clamp accuracy in a way that depends on the time constants and stiffness of the differential equations being solved. In simulations, time steps above 0.2 ms lead to catastrophic alteration of spike shape, but the frequency-vs.-current relationship is much more robust. Latency (the part of the time step that occurs between measuring membrane potential and injecting re-calculated membrane current) is a crucial factor as well. Experimental data are substantially more sensitive to inaccuracies than simulated data. PMID:18076999
Yadav, Yad Ram; Parihar, Vijay; Agarwal, Moneet; Bhatele, Pushp Raj
2012-01-01
The management of intraoperative bleeding during removal of a large hyper vascular meningioma is crucial for safe and efficient surgery. Preoperative embolization of meningioma is the best way to reduce vascularity of meningiomas but this technique is not readily available, costly and has its own limitations. The study is aimed to evaluate the use of temporary clamping of external carotid artery to reduce blood loss and operating time during excision of large convexity, parasagittal or temporal base meningiomas. A prospective study of 115 consecutively operated meningiomas of size 5 cms or more were operated from January 2002 to December2010. Temporary clamping of external carotid artery was done in 61 while 51 cases were managed without clamping. There was significant reduction of blood loss, operative time and blood transfusion given in the temporary clipping group compared to non clipping group. There was stitch abscess in two patients each in clamping, and non clamping group. There was no scalp necrosis or mortality in any of the group. Temporary clamping of external carotid artery is a safe, simple and cost-effective alternative to embolization for the surgery of large meningiomas. This can be practiced at all the centers.
MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C
Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.
2012-01-01
We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681
Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor
2017-09-01
Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% <1 year); 86 (45%) had a preceding balloon valvuloplasty. The indications for the procedure were stenotic (n = 123; 64%), regurgitant (n = 63; 33%) or combined (n = 7; 4%) disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Trojan, Michael; Kotelis, Drosos; Müller-Eschner, Matthias; Partovi, Sasan; Fink, Christian; Karmonik, Christof; Böckler, Dittmar; Kauczor, Hans-Ulrich; von Tengg-Kobligk, Hendrik
2017-01-01
Objective To prospectively evaluate our hypothesis that three-dimensional time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA) is able to detect hemodynamic alterations in patients with chronic expanding aortic dissection compared to stable aortic dissections. Materials and Methods 20 patients with chronic or residual aortic dissection in the descending aorta and patent false lumen underwent TR-MRA of the aorta at 1.5 T and repeated follow-up imaging (mean follow-up 5.4 years). 7 patients showed chronic aortic expansion and 13 patients had stable aortic diameters. Regions of interest were placed in the nondissected ascending aorta and the false lumen of the descending aorta at the level of the diaphragm (FL-diaphragm level) resulting in respective time-intensity curves. Results For the FL-diaphragm level, time-to-peak intensity and full width at half maximum were significantly shorter in the expansion group compared to the stable group (p = 0.027 and p = 0.003), and upward and downward slopes of time-intensity curves were significantly steeper (p = 0.015 and p = 0.005). The delay of peak intensity in the FL-diaphragm level compared to the nondissected ascending aorta was significantly shorter in the expansion group compared to the stable group (p = 0.01). Conclusions 3D TR-MRA detects significant alterations of hemodynamics within the patent false lumen of chronic expanding aortic dissections compared to stable aortic dissections. PMID:29317855
Duchi, Diego; Mazumder, Abhishek; Malinen, Anssi M; Ebright, Richard H; Kapanidis, Achillefs N
2018-06-06
RNA polymerase (RNAP) contains a mobile structural module, the 'clamp,' that forms one wall of the RNAP active-center cleft and that has been linked to crucial aspects of the transcription cycle, including promoter melting, transcription elongation complex stability, transcription pausing, and transcription termination. Using single-molecule FRET on surface-immobilized RNAP molecules, we show that the clamp in RNAP holoenzyme populates three distinct conformational states and interconvert between these states on the 0.1-1 s time-scale. Similar studies confirm that the RNAP clamp is closed in open complex (RPO) and in initial transcribing complexes (RPITC), including paused initial transcribing complexes, and show that, in these complexes, the clamp does not exhibit dynamic behaviour. We also show that, the stringent-response alarmone ppGpp, which reprograms transcription during amino acid starvation stress, selectively stabilizes the partly-closed-clamp state and prevents clamp opening; these results raise the possibility that ppGpp controls promoter opening by modulating clamp dynamics.
Accelerated recovery after cardiac operations.
Kaplan, Mehmet; Kut, Mustafa Sinan; Yurtseven, Nurgul; Cimen, Serdar; Demirtas, Mahmut Murat
2002-01-01
The accelerated-recovery approach, involving early extubation, early mobility, decreased duration of intensive care unit stay, and decreased duration of hospitalization has recently become a controversial issue in cardiac surgery. We investigated timing of extubation, length of intensive care unit stay, and duration of hospitalization in 225 consecutive cardiac surgery patients. Of the 225 patients, 139 were male and 86 were female; average age was 49.73 +/- 16.95 years. Coronary artery bypass grafting was performed in 127 patients; 65 patients underwent aortic and/or mitral or pulmonary valvular operations; 5 patients underwent valvular plus coronary artery operations; and in 28 patients surgical interventions for congenital anomalies were carried out. The accelerated-recovery approach could be applied in 169 of the 225 cases (75.11%). Accelerated-recovery patients were extubated after an average of 3.97 +/- 1.59 hours, and the average duration of stay in the intensive care unit was 20.93 +/- 2.44 hours for these patients. Patients were discharged if they met all of the following criteria: hemodynamic stability, cooperativeness, ability to initiate walking exercises within wards, lack of pathology in laboratory investigations, and psychological readiness for discharge. Mean duration of hospitalization for accelerated-recovery patients was 4.24 +/- 0.75 days. Two patients (1.18%) who were extubated within the first 6 hours required reintubation. Four patients (2.36%) who were sent to the wards returned to intensive care unit due to various reasons and 6 (3.55%) of the discharged patients were rehospitalized. Approaches for decreasing duration of intubation, intensive care unit stay and hospitalization may be applied in elective and uncomplicated cardiac surgical interventions with short duration of aortic cross-clamping and cardiopulmonary bypass, without risking patients. Frequencies of reintubation, return to intensive care unit, and rehospitalization are quite low with this approach.
Timing of cord clamping in very preterm infants: more evidence is needed.
Tarnow-Mordi, William O; Duley, Lelia; Field, David; Marlow, Neil; Morris, Jonathan; Newnham, John; Paneth, Nigel; Soll, Roger F; Sweet, David
2014-08-01
In December 2012, the American College of Obstetricians and Gynecologists published a Committee Opinion entitled "Timing of umbilical cord clamping after birth." It stated that "evidence exists to support delayed cord clamping in preterm infants, when feasible. The single most important benefit for preterm infants is the possibility for a nearly 50% reduction in IVH." However, the Committee Opinion added that the ideal timing of umbilical cord clamping has yet to be determined and recommended that large clinical trials be conducted in the most preterm infants. Published randomized controlled trials include <200 infants of <30 weeks' gestation, with assessments of neurodevelopmental outcome in less than one-half of the children. This is a major gap in the evidence. Without reliable data from randomized controlled trials that optimally include childhood follow-up evaluations, we will not know whether delayed cord clamping may do more overall harm than good. Ongoing trials of delayed cord clamping plan to report childhood outcomes in >2000 additional very preterm infants. Current recommendations may need to change when these results become available. Greater international collaboration could accelerate resolution of whether this promising intervention will improve disability-free survival in about 1 million infants who will be born very preterm globally each year. Copyright © 2014 Mosby, Inc. All rights reserved.
Mechanisms of the palmitoylcarnitine-induced response in vascular endothelial cells.
Taki, H; Muraki, K; Imaizumi, Y; Watanabe, M
1999-09-01
The mechanisms of Ca2+ mobilization induced by palmitoylcarnitine (Palcar) in rabbit aortic endothelial cells (ETCs) were examined using electrophysiological techniques. The results obtained were compared with those induced by acetylcholine (ACh). When a rabbit aortic muscle preparation with an intact endothelium was treated with 10 microM Palcar, the ACh-induced relaxation was markedly attenuated, whereas endothelium-independent relaxation caused by sodium nitroprusside was not affected. Under perforated-patch whole-cell-clamp conditions, the application of Palcar over the concentration range 0.3 and 10 microM elicited a slowly activating outward current (IPalcar-out), whereas ACh induced a rapidly activating outward current (IACh). A potassium channel blocker, 4-aminopyridine, significantly inhibited both IPalcar-out and IACh. Removal of external Ca2+ almost abolished IPalcar-out. Under the same conditions, however, IACh remained transient. Addition of cation channel blockers SK&F96365 and La3+ inhibited IPalcar-out more effectively than IACh. Application of staurosporine, an inhibitor of protein kinase C, affected neither IACh nor IPalcar-out. In contrast, treatment of ETCs with pertussis toxin (PTX) reduced IACh and almost abolished IPalcar-out. These findings demonstrate that, in ETCs, Palcar induces Ca2+ influx via the activation of PTX-sensitive GTP-binding protein, leading to the activation of Ca(2+)-dependent K+ current and hyperpolarization of the cell.
The inflammatory response to ruptured abdominal aortic aneurysm is altered by endovascular repair.
Makar, R R; Badger, S A; O'Donnell, M E; Soong, C V; Lau, L L; Young, I S; Hannon, R J; Lee, B
2013-01-01
Introduction. Ruptured abdominal aortic aneurysm (rAAA) causes a significant inflammatory response. The study aims to investigate this response following endovascular and open repair of ruptured AAA. Patients and Methods. Consecutive rAAA patients had either endovascular aneurysm repair (EVAR) or open repair (OR). Blood samples were taken for cytokines, lipid hydroperoxides (LOOH), antioxidants, and neutrophil elastase/ α 1-anti-trypsin complexes (NE/AAT) before surgery, 6 hours after clamp release and 1, 3, 5 days postoperatively. Results. 30 patients were included in the study, with 14 undergoing eEVAR and 16 eOR, with comparable baseline comorbidities, age, and parameters. IL-6 peaked higher in eOR patients (P = 0.04), while p75TNFr was similar between groups except at day 5 (P = 0.04). The NE/AAT concentrations were higher in eOR patients (P = 0.01), particularly in the first postoperative day, and correlated with blood (r = 0.398, P = 0.029) and platelet (r = 0.424, P = 0.020) volume transfused. C-reactive protein rose and lipid hydroperoxide fell in both groups without significant intergroup difference. Vitamins C and E, lycopene, and β -carotene levels were similar between groups. Conclusion. EVAR is associated with lower systemic inflammatory response compared to OR. Its increased future use may thereby improve outcomes for patients.
The Inflammatory Response to Ruptured Abdominal Aortic Aneurysm Is Altered by Endovascular Repair
Makar, R. R.; Badger, S. A.; O'Donnell, M. E.; Soong, C. V.; Lau, L. L.; Young, I. S.; Hannon, R. J.; Lee, B.
2013-01-01
Introduction. Ruptured abdominal aortic aneurysm (rAAA) causes a significant inflammatory response. The study aims to investigate this response following endovascular and open repair of ruptured AAA. Patients and Methods. Consecutive rAAA patients had either endovascular aneurysm repair (EVAR) or open repair (OR). Blood samples were taken for cytokines, lipid hydroperoxides (LOOH), antioxidants, and neutrophil elastase/α1-anti-trypsin complexes (NE/AAT) before surgery, 6 hours after clamp release and 1, 3, 5 days postoperatively. Results. 30 patients were included in the study, with 14 undergoing eEVAR and 16 eOR, with comparable baseline comorbidities, age, and parameters. IL-6 peaked higher in eOR patients (P = 0.04), while p75TNFr was similar between groups except at day 5 (P = 0.04). The NE/AAT concentrations were higher in eOR patients (P = 0.01), particularly in the first postoperative day, and correlated with blood (r = 0.398, P = 0.029) and platelet (r = 0.424, P = 0.020) volume transfused. C-reactive protein rose and lipid hydroperoxide fell in both groups without significant intergroup difference. Vitamins C and E, lycopene, and β-carotene levels were similar between groups. Conclusion. EVAR is associated with lower systemic inflammatory response compared to OR. Its increased future use may thereby improve outcomes for patients. PMID:24363936
Kawakami, Hironori; Su'etsugu, Masayuki; Katayama, Tsutomu
2006-10-01
In Escherichia coli, a complex consisting of Hda and the DNA-loaded clamp-subunit of the DNA polymerase III holoenzyme promotes hydrolysis of DnaA-ATP. The resultant ADP-DnaA is inactive for initiation of chromosomal DNA replication, thereby repressing excessive initiations. As the cellular content of the clamp is 10-100 times higher than that of Hda, most Hda molecules might be complexed with the clamp in vivo. Although Hda predominantly forms irregular aggregates when overexpressed, in the present study we found that co-overexpression of the clamp with Hda enhances Hda solubility dramatically and we efficiently isolated the Hda-clamp complex. A single molecule of the complex appears to consist of two Hda molecules and a single clamp. The complex is competent in DnaA-ATP hydrolysis and DNA replication in the presence of DNA and the clamp deficient subassembly of the DNA polymerase III holoenzyme (pol III*). These findings indicate that the clamp contained in the complex is loaded onto DNA through an interaction with the pol III* and that the Hda activity is preserved in these processes. The complex consisting of Hda and the DNA-unloaded clamp may play a specific role in a process proceeding to the DnaA-ATP hydrolysis in vivo.
MDCT evaluation of acute aortic syndrome (AAS)
Rossi, Giovanni; Lassandro, Francesco; Rea, Gaetano; Marino, Maurizio; Muto, Maurizio; Molino, Antonio; Scaglione, Mariano
2016-01-01
Non-traumatic acute thoracic aortic syndromes (AAS) describe a spectrum of life-threatening aortic pathologies with significant implications on diagnosis, therapy and management. There is a common pathway for the various manifestations of AAS that eventually leads to a breakdown of the aortic intima and media. Improvements in biology and health policy and diffusion of technology into the community resulted in an associated decrease in mortality and morbidity related to aortic therapeutic interventions. Hybrid procedures, branched and fenestrated endografts, and percutaneous aortic valves have emerged as potent and viable alternatives to traditional surgeries. In this context, current state-of-the art multidetector CT (MDCT) is actually the gold standard in the emergency setting because of its intrinsic diagnostic value. Management of acute aortic disease has changed with the increasing realization that endovascular therapies may offer distinct advantages in these situations. This article provides a summary of AAS, focusing especially on the MDCT technique, typical and atypical findings and common pitfalls of AAS, as well as recent concepts regarding the subtypes of AAS, consisting of aortic dissection, intramural haematoma, penetrating atherosclerotic ulcer and unstable aortic aneurysm or contained aortic rupture. MDCT findings will be related to pathophysiology, timing and management options to achieve a definite and timely diagnostic and therapeutic definition. In the present article, we review the aetiology, pathophysiology, clinical presentation, outcomes and therapeutic approaches to acute aortic syndromes. PMID:27033344
Upadhye, Kalpesh V.; Candiello, Joseph E.; Davidson, Lance A.; Lin, Hai
2011-01-01
Patch clamp is a powerful tool for studying the properties of ion-channels and cellular membrane. In recent years, planar patch clamp chips have been fabricated from various materials including glass, quartz, silicon, silicon nitride, polydimethyl-siloxane (PDMS), and silicon dioxide. Planar patch clamps have made automation of patch clamp recordings possible. However, most planar patch clamp chips have limitations when used in combination with other techniques. Furthermore, the fabrication methods used are often expensive and require specialized equipments. An improved design as well as fabrication and characterization of a silicon-based planar patch clamp chip are described in this report. Fabrication involves true batch fabrication processes that can be performed in most common microfabrication facilities using well established MEMS techniques. Our planar patch clamp chips can form giga-ohm seals with the cell plasma membrane with success rate comparable to existing patch clamp techniques. The chip permits whole-cell voltage clamp recordings on variety of cell types including Chinese Hamster Ovary (CHO) cells and pheochromocytoma (PC12) cells, for times longer than most available patch clamp chips. When combined with a custom microfluidics chamber, we demonstrate that it is possible to perfuse the extra-cellular as well as intra-cellular buffers. The chamber design allows integration of planar patch clamp with atomic force microscope (AFM). Using our planar patch clamp chip and microfluidics chamber, we have recorded whole-cell mechanosensitive (MS) currents produced by directly stimulating human keratinocyte (HaCaT) cells using an AFM cantilever. Our results reveal the spatial distribution of MS ion channels and temporal details of the responses from MS channels. The results show that planar patch clamp chips have great potential for multi-parametric high throughput studies of ion channel proteins. PMID:22174731
Protective effect of melatonin on experimental spinal cord ischemia.
Erten, S F; Kocak, A; Ozdemir, I; Aydemir, S; Colak, A; Reeder, B S
2003-10-01
Experimental animal model to assess ischemic spinal cord injury following occlusion of the thoraco-abdominal aorta. To measure whether melatonin administered to rabbits before and after occlusion exerts an effect on the repair of ischemia-reperfusion (IR) injury. Medical Biology Laboratory, Inonu University, Malatya, Turkey. Rabbits were divided into three IR treatment groups and one sham-operated (ShOp) control group. The three treatment groups had their infrarenal aorta temporarily occluded for 25 min, while the ShOp group had laparotomy without aortic occlusion. Melatonin was administered either 10 min before aortic occlusion or 10 min after the clamp was removed. Physiologic saline was administered to the control animals. After treatment, the animals were euthanized and lumbosacral spinal cord tissue was removed for the determination of relevant enzyme activities. Malondialdehyde levels, indicating the extent of lipid peroxidation, were found to be significantly increased in the nonmelatonin treated (IR) group when compared to the ShOp group. Melatonin, whether given to pre- or post occlusion groups, suppressed malondialdehyde levels below that of the ShOp group. Catalase (CAT) and glutathione peroxidase (GSH-Px) enzyme activities were increased in the IR group compared to the ShOp group. Melatonin given preocclusion resulted in a significant decrease in both CAT and GSH-Px enzyme levels. The superoxide dismutase (SOD) enzyme activity was decreased in the ischemia-reperfusion treatment group. However, the melatonin treatment increased SOD enzyme activity to levels approximating that of the ShOp group. To our knowledge, this is the first study that shows the effects of melatonin administered both pre- and postischemia on induced oxidative damage to injured spinal cords. Our data also expands on reports that melatonin administration may significantly reduce the incidence of spinal cord injury following temporary aortic occlusion.
An Ultrasonic Clamp for Bloodless Partial Nephrectomy
NASA Astrophysics Data System (ADS)
Lafon, Cyril; Bouchoux, Guillaume; Murat, François Joseph; Birer, Alain; Theillère, Yves; Chapelon, Jean Yves; Cathignol, Dominique
2007-05-01
Maximum conservation of the kidney is preferable through partial nephrectomy for patients at risk of disease recurrence of renal cancers. Haemostatic tools are needed in order to achieve bloodless surgery and reduce post surgery morbidity. Two piezo-ceramic transducers operating at a frequency of 4 MHz were mounted on each arm of a clamp. When used for coagulation purposes, two transducers situated on opposite arms of the clamp were driven simultaneously. Heat delivery was optimized as each transducers mirrored back to targeted tissues the wave generated by the opposite transducer. Real-time treatment monitoring with an echo-based technique was also envisaged with this clamp. Therapy was periodically interrupted so one transducer could generate a pulse. The echo returning from the opposite transducer was treated. Coagulation necroses were obtained in vitro on substantial thicknesses (23-38mm) of pig liver over exposure durations ranging from 30s to 130s, and with acoustic intensities of less than 15W/cm2 per transducer. Both kidneys of two pigs were treated in vivo with the clamp (14.5W/cm2 for 90s), and the partial nephrectomies performed proved to be bloodless. In vitro and in vivo, wide transfixing lesions corresponded to an echo energy decrease superior to -10dB and parabolic form of the time of flight versus treatment time. In conclusion, this ultrasound clamp has proven to be an excellent mean for achieving monitored haemostasis in kidney.
Aortic Dissection in Patients With Bicuspid Aortic Valve–Associated Aneurysms
Wojnarski, Charles M.; Svensson, Lars G.; Roselli, Eric E.; Idrees, Jay J.; Lowry, Ashley M.; Ehrlinger, John; Pettersson, Gösta B.; Gillinov, A. Marc; Johnston, Douglas R.; Soltesz, Edward G.; Navia, Jose L.; Hammer, Donald F.; Griffin, Brian; Thamilarasan, Maran; Kalahasti, Vidyasagar; Sabik, Joseph F.; Blackstone, Eugene H.; Lytle, Bruce W.
2016-01-01
Background Data regarding the risk of aortic dissection in patients with bicuspid aortic valve and large ascending aortic diameter are limited, and appropriate timing of prophylactic ascending aortic replacement lacks consensus. Thus our objectives were to determine the risk of aortic dissection based on initial cross-sectional imaging data and clinical variables and to isolate predictors of aortic intervention in those initially prescribed serial surveillance imaging. Methods From January 1995 to January 2014, 1,181 patients with bicuspid aortic valve underwent cross-sectional computed tomography (CT) or magnetic resonance imaging (MRI) to ascertain sinus or tubular ascending aortic diameter greater than or equal to 4.7 cm. Random Forest classification was used to identify risk factors for aortic dissection, and among patients undergoing surveillance, time-related analysis was used to identify risk factors for aortic intervention. Results Prevalence of type A dissection that was detected by imaging or was found at operation or on follow-up was 5.3% (n = 63). Probability of type A dissection increased gradually at a sinus diameter of 5.0 cm—from 4.1% to 13% at 7.2 cm—and then increased steeply at an ascending aortic diameter of 5.3 cm—from 3.8% to 35% at 8.4 cm—corresponding to a cross-sectional area to height ratio of 10 cm2/m for sinuses of Valsalva and 13 cm2/m for the tubular ascending aorta. Cross-sectional area to height ratio was the best predictor of type A dissection (area under the curve [AUC] = 0.73). Conclusions Early prophylactic ascending aortic replacement in patients with bicuspid aortic valve should be considered at high-volume aortic centers to reduce the high risk of preventable type A dissection in those with aortas larger than approximately 5.0 cm or with a cross-sectional area to height ratio greater than approximately 10 cm2/m. PMID:26209494
Influence of clamp-up force on the strength of bolted composite joints
NASA Astrophysics Data System (ADS)
Horn, Walter J.; Schmitt, Ron R.
1994-03-01
Composite materials offer the potential for a reduction in the number of individual parts and joints in a structure because large one-piece components can replace multipart assemblies. Nevertheless, there are many situations where composite parts must be joined and often mechanical fasteners provide the only practical method of joining those parts. The long-term strength of mechanically fastened joints of composite members can be directly affected by the clamp-up force of the fastener and thus perhaps by the relaxation of this force due to the viscoelastic character of the composite materials of the joint. Methods for predicting the effect of bolt clamp-up force relaxation on the strength of mechanically fastened joints of thermoplastic composite materials were investigated during the present study. A test program, using two thermoplastic composite materials, was conducted to determine the influence of clamp-up force on joint strength, to measure the relaxation of the joint clamp-up force with time, and to measure the change of joint strength as a function of time.
Implementation of a fast 16-Bit dynamic clamp using LabVIEW-RT.
Kullmann, Paul H M; Wheeler, Diek W; Beacom, Joshua; Horn, John P
2004-01-01
The dynamic-clamp method provides a powerful electrophysiological tool for creating virtual ionic conductances in living cells and studying their influence on membrane potential. Here we describe G-clamp, a new way to implement a dynamic clamp using the real-time version of the Lab-VIEW programming environment together with a Windows host, an embedded microprocessor that runs a real-time operating system and a multifunction data-acquisition board. The software includes descriptions of a fast voltage-dependent sodium conductance, delayed rectifier, M-type and A-type potassium conductances, and a leak conductance. The system can also read synaptic conductance waveforms from preassembled data files. These virtual conductances can be reliably implemented at speeds < or =43 kHz while simultaneously saving two channels of data with 16-bit precision. G-clamp also includes utilities for measuring current-voltage relations, synaptic strength, and synaptic gain. Taking an approach built on a commercially available software/hardware platform has resulted in a system that is easy to assemble and upgrade. In addition, the graphical programming structure of LabVIEW should make it relatively easy for others to adapt G-clamp for new experimental applications.
Dynamic Clamp in Cardiac and Neuronal Systems Using RTXI
Ortega, Francis A.; Butera, Robert J.; Christini, David J.; White, John A.; Dorval, Alan D.
2016-01-01
The injection of computer-simulated conductances through the dynamic clamp technique has allowed researchers to probe the intercellular and intracellular dynamics of cardiac and neuronal systems with great precision. By coupling computational models to biological systems, dynamic clamp has become a proven tool in electrophysiology with many applications, such as generating hybrid networks in neurons or simulating channelopathies in cardiomyocytes. While its applications are broad, the approach is straightforward: synthesizing traditional patch clamp, computational modeling, and closed-loop feedback control to simulate a cellular conductance. Here, we present two example applications: artificial blocking of the inward rectifier potassium current in a cardiomyocyte and coupling of a biological neuron to a virtual neuron through a virtual synapse. The design and implementation of the necessary software to administer these dynamic clamp experiments can be difficult. In this chapter, we provide an overview of designing and implementing a dynamic clamp experiment using the Real-Time eXperiment Interface (RTXI), an open- source software system tailored for real-time biological experiments. We present two ways to achieve this using RTXI’s modular format, through the creation of a custom user-made module and through existing modules found in RTXI’s online library. PMID:25023319
McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J
2014-01-01
A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P < .01). At follow-up (median, 312 days; range, 0-1429 days), the mean aortic insufficiency score remained low for the patients with central aortic valve closure (0.27 ± 0.46) in contrast to those without central aortic valve closure who experienced aortic insufficiency progression (0.78 ± 0.89; P = .02). In addition, the proportion of patients with more than mild aortic insufficiency was significantly less in the central aortic valve closure group (0% vs 18%; P = .05). The patients in the central aortic valve closure group were significantly older and had a greater incidence of renal failure at baseline. The 30-day mortality was greater in the central aortic valve closure group, but the late survival was similar between the 2 groups. No reoperations were required for recurrent aortic insufficiency. The results of our study have shown that repair of aortic insufficiency with a simple central coaptation stitch is effective and durable in left ventricular assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Etz, Christian D; Homann, Tobias M; Luehr, Maximilian; Kari, Fabian A; Weisz, Donald J; Kleinman, George; Plestis, Konstadinos A; Griepp, Randall B
2008-06-01
Spinal cord blood flow (SCBF) after sacrifice of thoracoabdominal aortic segmental arteries (TAASA) during thoracoabdominal aortic aneurysm (TAAA) repair remains poorly understood. This study explored SCBF for 72 h after sacrifice of all TAASA. Fourteen juvenile Yorkshire pigs underwent complete serial TAASA sacrifice (T4-L5). Six control pigs underwent anesthesia and cooling to 32 degrees C with no TAASA sacrifice. In the experimental animals, spinal cord function was continuously monitored using motor evoked potentials (MEPs) until 1h after clamping the last TAASA. Fluorescent microspheres enabled segmental measurement of SCBF along the entire spinal cord before, and 5 min, 1 h, 5 h, 24 h and 72 h after complete TAASA sacrifice. A modified Tarlov score was obtained for 3 days after surgery. All the pigs with complete TAASA sacrifice retained normal cord function (MEP) until 1h after TAASA ligation. Seven pigs (50%) with complete TAASA sacrifice recovered after 72 h; seven pigs suffered paraparesis or paraplegia. Intraoperatively, and until 1h postoperatively, SCBF was similar among the three groups along the entire cord. Postoperatively, SCBF did not decrease in any group, but significant hyperemia occurred at 5h in controls and recovery animals, but did not occur in pigs that developed paraparesis or paraplegia in the T8-L2 segments (p=0.0002) and L3-S segments (p=0.0007). At 24h, SCBF remained marginally lower from T8 caudally; at 72h, SCBF was similar among all groups along the entire cord. SCBF in the segments T8-L2 at 5h predicted functional recovery (p=0.003). This study suggests that critical spinal cord ischemia after complete TAASA sacrifice does not occur immediately (intraoperatively), but is delayed 1-5h or longer after clamping, and represents failure to mount a hyperemic response to rewarming and awakening. The short duration of low SCBF associated with spinal cord injury suggests that hemodynamic and metabolic manipulation lasting only 24-72 h may allow routine preservation of normal cord function despite sacrifice of all TAASA secondary to surgical or endovascular repair of large TAAA.
NASA Astrophysics Data System (ADS)
Sharma, K.; Abdul Khudus, M. I. M.; Alam, S. U.; Bhattacharya, S.; Venkitesh, D.; Brambilla, G.
2018-01-01
Relative performance and detection limit of conventional, amplified, and gain-clamped cavity ring-down techniques (CRDT) in all-fiber configurations are compared experimentally for the first time. Refractive index measurement using evanescent field in tapered fibers is used as a benchmark for the comparison. The systematic optimization of a nested-loop configuration in gain-clamped CRDT is also discussed, which is crucial for achieving a constant gain in a CRDT experiment. It is found that even though conventional CRDT has the lowest standard error in ring-down time (Δτ), the value of ring-down time (τ) is very small, thus leading to poor detection limit. Amplified CRDT provides an improvement in τ, albeit with two orders of magnitude higher Δτ due to amplifier noise. The nested-loop configuration in gain-clamped CRDT helps in reducing Δτ by an order of magnitude as compared to amplified CRDT whilst retaining the improvement in τ. A detection limit of 1 . 03 × 10-4 RIU at refractive index of 1.322 with a 3 mm long and 4.5 μm diameter tapered fiber is demonstrated with the gain-clamped CRDT.
Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.
Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas
2011-12-01
As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.
Electrostatic Interactions at the Dimer Interface Stabilize the E. coli β Sliding Clamp.
Purohit, Anirban; England, Jennifer K; Douma, Lauren G; Tondnevis, Farzaneh; Bloom, Linda B; Levitus, Marcia
2017-08-22
Sliding clamps are ring-shaped oligomeric proteins that encircle DNA and associate with DNA polymerases for processive DNA replication. The dimeric Escherichia coli β-clamp is closed in solution but must adopt an open conformation to be assembled onto DNA by a clamp loader. To determine what factors contribute to the stability of the dimer interfaces in the closed conformation and how clamp dynamics contribute to formation of the open conformation, we identified conditions that destabilized the dimer and measured the effects of these conditions on clamp dynamics. We characterized the role of electrostatic interactions in stabilizing the β-clamp interface. Increasing salt concentration results in decreased dimer stability and faster subunit dissociation kinetics. The equilibrium dissociation constant of the dimeric clamp varies with salt concentration as predicted by simple charge-screening models, indicating that charged amino acids contribute to the remarkable stability of the interface at physiological salt concentrations. Mutation of a charged residue at the interface (Arg-103) weakens the interface significantly, whereas effects are negligible when a hydrophilic (Ser-109) or a hydrophobic (Ile-305) amino acid is mutated instead. It has been suggested that clamp opening by the clamp loader takes advantage of spontaneous opening-closing fluctuations at the clamp's interface, but our time-resolved fluorescence and fluorescence correlation experiments rule out conformational fluctuations that lead to a significant fraction of open states. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Cobbs, W H; Pugh, E N
1987-01-01
1. Membrane currents initiated by intense, 20 microseconds flashes (photocurrents) were recorded from isolated salamander rods by combined extracellular suction electrodes and intracellular tight-seal electrodes either in current or voltage clamp mode. The magnitudes (mean +/- 2 S.E.M.) of the maximal photoresponses recorded by the suction and by the intracellular electrode respectively were 40 +/- 5 pA (n = 18) and 35 +/- 7 mV (n = 8) for current clamp at zero current; 43 +/- 9 pA and 66 +/- 13 (n = 11) pA for voltage clamp at the zero-current holding potential, -24 +/- 3 mV. 2. Photocurrents initiated by flashes isomerizing 0.1% or more of the outer segment's rhodopsin achieved a saturated velocity and were 95% complete in less than 50 ms. The effect of incrementing flash intensity above 0.1% isomerization can be described as a translation of the photocurrent along the time axis towards the origin. Within the interval 0-50 ms the latter two-thirds of the velocity-saturated photocurrent is well described as a single-exponential decay. The decay was much faster in voltage clamp (2.8 +/- 1.2 ms, n = 11) than in current clamp mode (17 +/- 5 ms, n = 17). 3. The initial third of the velocity-saturated photocurrent, occurring over the interval from the flash to the onset of exponential decay, followed about the same time course in current and voltage clamp. The time interval occupied by this initial 'latent' phase decreased with increasing flash intensity and attained an apparent minimum of about 7 ms in response to flashes isomerizing 10% or more of the rhodopsin at ca. 22 degrees C. 4. The hypothesis that the decay of outer segment light-sensitive membrane current is the same in current and voltage clamp was supported by an analysis of the difference between outer segment currents measured successively in the two recording modes. First, the tail of the difference current decayed exponentially with a time constant approximately equal to R x C, where R and C are independently estimated slope resistance and capacitance of the rod. Secondly, the integral of the difference current, when divided by outer segment capacitance, closely approximated the hyperpolarizing light response measured under current clamp. Thus, displacement current accounted for the difference between photocurrents measured in current and voltage clamp.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:2832596
Yıldız, Banu Şahin; Şahin, Alparslan; Aladağ, Nazire Başkurt; Arslan, Gülgün; Kaptanoğulları, Hakan; Akın, İbrahim; Yıldız, Mustafa
2015-01-01
Objective: The effects of acute hemodialysis session on pulse wave velocity are conflicting. The aim of the current study was to assess the acute effects of ultrafiltration on the aortic mechanical properties using carotid-femoral (aortic) pulse wave velocity and pulse propagation time. Methods: A total of 26 (12 women, 14 men) consecutive patients on maintenance hemodialysis (mean dialysis duration: 40.7±25.6 (4-70) months) and 29 healthy subjects (13 women, 16 men) were included in this study. Baseline blood pressure, carotid-femoral (aortic) pulse wave velocity, and pulse propagation time were measured using a Complior Colson device (Createch Industrie, France) before and immediately after the end of the dialysis session. Results: While systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse pressure, and pulse wave velocity were significantly higher in patients on hemodialysis than in healthy subjects, pulse propagation time was significantly higher in healthy subjects. Although body weight, systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse pressure, and pulse wave velocity were significantly decreased, heart rate and pulse propagation time were significantly increased after ultrafiltration. There was a significant positive correlation between pulse wave velocity and age, body height, waist circumference, systolic blood pressure, diastolic blood pressure, mean blood pressure, pulse pressure, and heart rate. Conclusion: Although hemodialysis treatment may chronically worsen aortic mechanical properties, ultrafiltration during hemodialysis may significantly improve aortic pulse wave velocity, which is inversely related to aortic distensibility and pulse propagation time. PMID:25413228
Prasetyono, Theddeus O H; Adianto, Senja
2013-09-01
The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. The mean times from the vessel clamping until the saturation became undetectable were 20.19±2.13 seconds and 74.91±10.57 seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was 34.5±11.72 minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.
Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.
Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T
2013-04-01
Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Chang, Kuo-Chu; Hsu, Kwan-Lih; Tseng, Yung-Zu
2003-01-01
We determined the effects of diabetes and gender on the physical properties of the vasculature in streptozotocin (STZ)-treated rats based on the aortic input impedance analysis. Rats given STZ 65 mg/kg i.v. were compared with untreated age-matched controls. Pulsatile aortic pressure and flow signals were measured and were then subjected to Fourier transformation for the analysis of aortic input impedance. Wave transit time was determined using the impulse response function of the filtered aortic input impedance spectra. Male but not female diabetic rats exhibited an increase in cardiac output in the absence of any significant changes in arterial blood pressure, resulting in a decline in total peripheral resistance. However, in each gender group, diabetes contributed to an increase in wave reflection factor, from 0.47 +/- 0.04 to 0.84 +/- 0.03 in males and from 0.46 +/- 0.03 to 0.81 +/- 0.03 in females. Diabetic rats had reduced wave transit time, at 18.82 +/- 0.60 vs 21.34 +/- 0.51 msec in males and at 19.63 +/- 0.37 vs 22.74 +/- 0.57 msec in females. Changes in wave transit time and reflection factor indicate that diabetes can modify the timing and magnitude of the wave reflection in the rat arterial system. Meanwhile, diabetes produced a fall in aortic characteristic impedance from 0.023 +/- 0.002 to 0.009 +/- 0.001 mmHg/min/kg/ml in males and from 0.028 +/- 0.002 to 0.014 +/- 0.001 mmHg/min/kg/ml in females. With unaltered aortic pressure, both the diminished aortic characteristic impedance and wave transit time suggest that the muscle inactivation in diabetes may occur in aortas and large arteries and may cause a detriment to the aortic distensibility in rats with either sex. We conclude that only rats with male gender diabetes produce a detriment to the physical properties of the resistance arterioles. In spite of male or female gender, diabetes decreases the aortic distensibility and impairs the wave reflection phenomenon in the rat arterial system.
Jorge, G D L; Tártaro, R R; Escanhoela, C A F; Boin, I D F S F
2016-09-01
Biliary complications are important causes of morbidity and mortality in patients undergoing hepatic surgery. The aim of the study was to evaluate late liver alterations after a long period of choledochal clamping in Wistar rats. Ten male Wistar rats, weighing 304 grams, anesthetized with sodium thiopental (25 mg/kg) and xylazine (10 mg/kg) intravenously, were distributed into 2 groups: the choledochal clamping group (CCG) and the operation sham group (OSG), with 5 animals each submitted to an abdominal incision. In the CCG, the choledochal was isolated, dissected, and clamped with a microvascular clamp for 40 minutes. After this occlusion time, the clamp was removed and the incision was closed. In the OSG the animals, under normal conditions, were submitted only to anesthesia and laparotomy for choledochal manipulation. In all animals, after the 31st day, a hepatic biopsy was carried out for histology and blood biochemical tests: total bilirubin, alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, and gamma-glutamyl transferase. The animals were euthanized under anesthesia. This research was approved by the Ethics Committee on Animal Use (CEUA, Unicamp, No. 2511-1). In the CCG, 100% of the animals showed bile duct dilatation, ductular proliferation, and portal inflammatory infiltrate; 60% showed regenerative nodule formation; and 80% had porta-porta septa and foci of necrosis, all of which were not found in the OSG. All CCG group biochemical tests had significant increases (P < .05) compared with OSG. Long-time choledochal clamping in Wistar rats caused hepatic dysfunction and biochemical and histological injuries with degrees of distortion to the hepatic architecture. Copyright © 2016 Elsevier Inc. All rights reserved.
Wang, Yinghua; Xue, Song; Zhu, Hongsheng
2013-04-30
The purpose of this study is to identify the risk factors for postoperative hypoxemia in patients with Stanford A aortic dissection surgery and their relation to clinical outcomes. Clinical records of 186 patients with postoperative hypoxemia in Stanford A aortic dissection were analyzed retrospectively. The patients were divided into two groups by postoperative oxygen fraction (PaO2/FiO2):hypoxemia group (N=92) and non-hypoxemia group (N=94). We found that the incidence of postoperative hypoxemia was 49.5%. Statistical analysis by t-test and χ2 indicated that acute onset of the aortic dissection (p=0.000), preoperative oxygen fraction (PaO2/FiO2) ≤200 mmHg(p=0.000), body mass index (p=0.008), circulatory arrest (CA) time (p=0.000) and transfusion more than 3000 ml(p=0.000) were significantly associated with postoperative hypoxemia. Multiple logistic regression analysis showed that preoperative hypoxemia, CA time and transfusion more than 3000 ml were independently associated with postoperative hypoxemia in Stanford A aortic dissection. Our results suggest that postoperative hypoxemia is a common complication in patients treated by Stanford A aortic dissection surgery. Preoperative oxygen fraction lower than 200 mmHg, longer CA time and transfusion more than 3000 ml are predictors of postoperative hypoxemia in Stanford A aortic dissection.
Wijeysundera, Harindra C; Wong, William W L; Bennell, Maria C; Fremes, Stephen E; Radhakrishnan, Sam; Peterson, Mark; Ko, Dennis T
2014-10-01
There is increasing demand for transcatheter aortic valve replacement (TAVR) as the primary treatment option for patients with severe aortic stenosis who are high-risk surgical candidates or inoperable. We used mathematical simulation models to estimate the hypothetical effectiveness of TAVR with increasing wait times. We applied discrete event modelling, using data from the Placement of Aortic Transcatheter Valves (PARTNER) trials. We compared TAVR with medical therapy in the inoperable cohort, and compared TAVR to conventional aortic valve surgery in the high-risk cohort. One-year mortality and wait-time deaths were calculated in different scenarios by varying TAVR wait times from 10 days to 180 days, while maintaining a constant wait time for surgery at a mean of 15.6 days. In the inoperable cohort, the 1-year mortality for medical therapy was 50%. When the TAVR wait time was 10 days, the TAVR wait-time mortality was 1.9% with a 1-year mortality of 31.5%. TAVR wait-time deaths increased to 28.9% with a 180-day wait, with a 1-year mortality of 41.4%. In the high-risk cohort, the wait-time deaths and 1-year mortality for the surgical patients were 2.5% and 27%, respectively. The TAVR wait-time deaths increased from 2.2% with a 10-day wait to 22.4% with a 180-day wait, and a corresponding increase in 1-year mortality from 24.5% to 32.6%. Mortality with TAVR exceeded surgery when TAVR wait times exceeded 60 days. Modest increases in TAVR wait times have a substantial effect on the effectiveness of TAVR in inoperable patients and high-risk surgical candidates. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
HTS techniques for patch clamp-based ion channel screening - advances and economy.
Farre, Cecilia; Fertig, Niels
2012-06-01
Ten years ago, the first publication appeared showing patch clamp recordings performed on a planar glass chip instead of using a conventional patch clamp pipette. "Going planar" proved to revolutionize ion channel drug screening as we know it, by allowing high quality measurements of ion channels and their effectors at a higher throughput and at the same time de-skilling the highly laborious technique. Over the years, platforms evolved in response to user requirements regarding experimental features, data handling plus storage, and suitable target diversity. This article gives a snapshot image of patch clamp-based ion channel screening with focus on platforms developed to meet requirements of high-throughput screening environments. The commercially available platforms are described, along with their benefits and drawbacks in ion channel drug screening. Automated patch clamp (APC) platforms allow faster investigation of a larger number of ion channel active compounds or cell clones than previously possible. Since patch clamp is the only method allowing direct, real-time measurements of ion channel activity, APC holds the promise of picking up high quality leads, where they otherwise would have been overseen using indirect methods. In addition, drug candidate safety profiling can be performed earlier in the drug discovery process, avoiding late-phase compound withdrawal due to safety liability issues, which is highly costly and inefficient.
Different methods of hilar clamping during partial nephrectomy: Impact on renal function.
Lee, Jeong Woo; Kim, Hwanik; Choo, Minsoo; Park, Yong Hyun; Ku, Ja Hyeon; Kim, Hyeon Hoe; Kwak, Cheol
2014-03-01
To evaluate the impact of different hilar clamping methods on changes in renal function after partial nephrectomy. We analyzed the clinical data of 369 patients who underwent partial nephrectomy for a single renal tumor of size ≤4.0 cm and a normal contralateral kidney. Patients were separated into three groups depending on hilar clamping method: non-clamping, cold ischemia and warm ischemia. Estimated glomerular filtration rate was examined at preoperative, nadir and 1 year postoperatively. Percent change in estimated glomerular filtration rate was used as the parameter to assess the renal functional outcome. Percent change in nadir estimated glomerular filtration rate in the non-clamping group was significantly less compared with the cold ischemia and warm ischemia groups (P < 0.001). However, no significant differences among the groups were noted in percent change of estimated glomerular filtration rate at 1 year (P = 0.348). The cold ischemia group had a similar serial change of postoperative renal function compared with the warm ischemia group. Percent change in 1-year estimated glomerular filtration rate increased with increasing ischemia time in the cold ischemia (P for trend = 0.073) and warm ischemia groups (P for trend = 0.010). On multivariate analysis, hilar clamping (both warm ischemia and cold ischemia) were significantly associated with percent change in nadir estimated glomerular filtration rate, but not in 1-year estimated glomerular filtration rate. Non-clamping partial nephrectomy results in a lower percent change in nadir estimated glomerular filtration rate, whereas it carries an estimated glomerular filtration rate change at 1 year that is similar to partial nephrectomy with cold ischemia and warm ischemia. Cold ischemia and warm ischemia provide a similar effect on renal function. Therefore, when hilar clamping is required, minimization of ischemia time is necessary. © 2013 The Japanese Urological Association.
[Progress and challenge of Stanford type A aortic dissection in China].
Sun, L Z; Li, J R
2017-04-01
In recent 20 years, the rapid development of acute Stanford type A aortic dissection in China has been mainly due to three aspects: (1) the refined classification of aortic dissection based on Stanford classification, (2) right axillary artery canal and selective cerebral perfusion technology become basic cardiopulmonary bypass strategy for Stanford type A aortic dissection, and (3) total aortic arch replacement and descending aortic stent graft surgery (Sun's surgery) become the standard treatment of Stanford type A aortic dissection. However, there are still many problems in the diagnosis and treatment of aortic dissection in China, such as: (1) unstandardized, lack of comprehensive guidelines of aortic dissection, (2) immature, perioperative organ protection and intraoperative blood protection technology remains a big flaw, and (3) it takes a long time to get patient prepared for surgery. In conclusion, as to the issue of the management of acute Stanford type A aortic dissection, there will be a long way for Chinese doctors to go. Peers should pay more attention to this problem and take more efforts, so that the outcome of acute Stanford type A aortic dissection surgical patients can be improved.
Concomitant transcatheter aortic valve and left ventricular assist device implantation.
Baum, Christina; Seiffert, Moritz; Treede, Hendrik; Reichenspurner, Hermann; Deuse, Tobias
2013-01-01
Relevant aortic regurgitation (AR) requires surgical repair at the time of left ventricular assist device (LVAD) implantation to reduce recirculation and ensure adequate forward flow. We report here on a patient with moderate AR in a noncalcified aortic valve and extensive calcification of the ascending aorta. The latter precluded aortic-crossclamping and, thus, surgical intervention on the aortic valve. Although there were no valvular or annular calcifications, a JenaValve transcatheter heart valve was successfully placed transapically with subsequent LVAD implantation in one operation. We believe concomitant transcatheter aortic valve implantation (TAVI) and LVAD implantation is a promising hybrid procedure, even in patients with pure AR.
Cell-Detection Technique for Automated Patch Clamping
NASA Technical Reports Server (NTRS)
McDowell, Mark; Gray, Elizabeth
2008-01-01
A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.
Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H
2015-06-09
Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p < 0.001). Thoracic aortic aneurysms were significantly more likely to be diagnosed in late follow-up in patients with Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p < 0.001). Patients with Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p < 0.001). The much higher long-term rates of aortic complications after AVR observed in patients with Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Ouweneel, Dagmar M; Sjauw, Krischan D; Wiegerinck, Esther M A; Hirsch, Alexander; Baan, Jan; de Mol, Bas A J M; Lagrand, Wim K; Planken, R Nils; Henriques, José P S
2016-10-01
The use of intracardiac assist devices is expanding, and correct position of these devices is required for optimal functioning. The aortic valve is an important landmark for positioning of those devices. It would be of great value if the device position could be easily monitored on plain supine chest radiograph in the ICU. We introduce a ratio-based tool for determination of the aortic valve location on plain supine chest radiograph images, which can be used to evaluate intracardiac device position. Retrospective observational study. Large academic medical center. Patients admitted to the ICU and supported by an intracardiac assist device. We developed a ratio to determine the aortic valve location on supine chest radiograph images. This ratio is used to assess the position of a cardiac assist device and is compared with echocardiographic findings. Supine anterior-posterior chest radiographs of patients with an aortic valve prosthesis (n = 473) were analyzed to determine the location of the aortic valve. We calculated several ratios with the potential to determine the position of the aortic valve. The aortic valve location ratio, defined as the distance between the carina and the aortic valve, divided by the thoracic width, was found to be the best performing ratio. The aortic valve location ratio determines the location of the aortic valve caudal to the carina, at a distance of 0.25 ± 0.05 times the thoracic width for male patients and 0.28 ± 0.05 times the thoracic width for female patients. The aortic valve location ratio was validated using CT images of patients with angina pectoris without known valvular disease (n = 95). There was a good correlation between cardiac device position (Impella) assessed with the aortic valve location ratio and with echocardiography (n = 53). The aortic valve location ratio enables accurate and reproducible localization of the aortic valve on supine chest radiograph. This tool is easily applicable and can be used for assessment of cardiac device position in patients on the ICU.
NASA Technical Reports Server (NTRS)
Levy, Samuel; Krupen, Philip
1943-01-01
The von Karman equations for flat plates are solved beyond the buckling load up to edge strains equal to eight time the buckling strain, for the extreme case of rigid clamping along the edges parallel to the load. Deflections, bending stresses, and membrane stresses are given as a function of end compressive load. The theoretical values of effective width are compared with the values derived for simple support along the edges parallel to the load. The increases in effective width due to rigid clamping drops from about 20 percent near the buckling strain to about 8 percent at an edge strain equal to eight times the buckling strain. Experimental values of effective width in the elastic range reported in NACA Technical Note No. 684 are between the theoretical curves for the extremes of simple support and rigid clamping.
Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A
2014-05-01
The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.
Ramos, Joyce S; Dalleck, Lance C; Ramos, Maximiano V; Borrani, Fabio; Roberts, Llion; Gomersall, Sjaan; Beetham, Kassia S; Dias, Katrin A; Keating, Shelley E; Fassett, Robert G; Sharman, James E; Coombes, Jeff S
2016-10-01
Decreased aortic reservoir function leads to a rise in aortic reservoir pressure that is an independent predictor of cardiovascular events. Although there is evidence that high-intensity interval training (HIIT) would be useful to improve aortic reservoir pressure, the optimal dose of high-intensity exercise to improve aortic reservoir function has yet to be investigated. Therefore, this study compared the effect of different volumes of HIIT and moderate-intensity continuous training (MICT) on aortic reservoir pressure in participants with the metabolic syndrome (MetS). Fifty individuals with MetS were randomized into one of the following 16-week training programs: MICT [n = 17, 30 min at 60-70% peak heart rate (HRpeak), five times/week]; 4 × 4-min high-intensity interval training (4HIIT) (n = 15, 4 × 4 min bouts at 85-95% HRpeak, interspersed with 3 min of active recovery at 50-70% HRpeak, three times/week); and 1 × 4-min high-intensity interval training (1HIIT) (n = 18, 1 × 4 min bout at 85-95% HRpeak, three times/week). Aortic reservoir pressure was calculated from radial applanation tonometry. Although not statistically significant, there was a trend for a small-to-medium group × time interaction effect on aortic reservoir pressure, indicating a positive adaptation following 1HIIT compared with 4HIIT and MICT [F (2,46) = 2.9, P = 0.07, η = 0.06]. This is supported by our within-group analysis wherein only 1HIIT significantly decreased aortic reservoir pressure from pre to postintervention (pre-post: 1HIIT 33 ± 16 to 31 ± 13, P = 0.03; MICT 29 ± 9-28 ± 8, P = 0.78; 4HIIT 28 ± 10-30 ± 9 mmHg, P = 0.10). Three sessions of 4 min of high-intensity exercise per week (12 min/week) was sufficient to improve aortic reservoir pressure, and thus may be a time-efficient exercise modality for reducing cardiovascular risk in individuals with MetS.
Vibration mode analysis of the proton exchange membrane fuel cell stack
NASA Astrophysics Data System (ADS)
Liu, B.; Liu, L. F.; Wei, M. Y.; Wu, C. W.
2016-11-01
Proton exchange membrane fuel cell (PEMFC) stacks usually undergo vibration during packing, transportation, and serving time, in particular for those used in the automobiles or portable equipment. To study the stack vibration response, based on finite element method (FEM), a mode analysis is carried out in the present paper. Using this method, we can distinguish the local vibration from the stack global modes, predict the vibration responses, such as deformed shape and direction, and discuss the effects of the clamping configuration and the clamping force magnitude on vibration modes. It is found that when the total clamping force remains the same, increasing the bolt number can strengthen the stack resistance to vibration in the clamping direction, but cannot obviously strengthen stack resistance to vibration in the translations perpendicular to clamping direction and the three axis rotations. Increasing the total clamping force can increase both of the stack global mode and the bolt local mode frequencies, but will decrease the gasket local mode frequency.
Tsutsumi, Koji; Hashizume, Kenichi; Inoue, Yoshito
2016-05-01
The purpose of this study was to clarify the natural history of the ascending aorta and to identify risk factors for late ascending aortic events after first isolated aortic valve replacement (AVR). A total of 287 patients undergoing AVR were enrolled. The patients were categorized into two groups based on the diameter of the ascending aorta at the time of AVR, as determined by computed tomography: Group A (n = 233) was defined as an ascending aortic diameter <40 mm, and Group B (n = 54) was defined as an ascending aortic diameter ≥40 mm. The mean follow-up period was 7.6 years. The baseline diameter of the ascending aorta was 31.4 ± 4.8 mm in Group A and 44.7 ± 4.2 mm in Group B. These values increased to 35.9 ± 7.4 mm in Group A and 50.1 ± 7.3 mm in Group B during the follow-up period (P < 0.001). Ten patients had acute type A aortic dissection (Group A: 1 patient vs. Group B: 9 patients; P < 0.001), and three patients had enlargement of the ascending aorta to ≥55 mm in diameter (Group A: 1 patient vs. Group B: 2 patients). Multivariate analysis revealed that the baseline ascending aortic diameter was the only significant risk factor for developing late ascending aortic events (P < 0.001). AVR alone may not prevent further enlargement of the ascending aorta. An ascending aorta ≥40 mm in diameter at the time of AVR increased the risk of late ascending aortic events.
Donndorf, Peter; Park, Hannah; Vollmar, Brigitte; Alms, Angela; Gierer, Philipp; Steinhoff, Gustav; Kaminski, Alexander
2014-08-01
Closed minimal extracorporeal circulation (MECC) systems currently do not represent the standard of surgical care for open-heart surgery. Yet, considering the beneficial results reported for coronary artery bypass graft (CABG) surgery, we used an MECC system in aortic valve replacement (AVR) and analysed the effects on intraoperative microvascular perfusion in comparison with conventional open extracorporeal circulation (CECC). In the current study, we analysed alterations in microvascular perfusion at 4 predefined time points (T1-T4) during surgical AVR utilizing orthogonal polarization spectral (OPS) imaging. Twenty patients were randomized for being operated on utilizing either MECC or CECC. Changes in functional capillary density (FCD, cm/cm(2)), mircovascular blood flow velocity (mm/s) and vessel diameter (μm) were analysed by a blinded investigator. After the start of extracorporeal circulation and aortic cross-clamping (T2), both groups showed a significant drop in FCD, but with a significantly higher FCD in the MECC group (153.1 ± 15.0 cm/cm² in the CECC group vs 160.8 ± 12.2 cm/cm² in the MECC group, P = 0.034). During the late phase of the cardiopulmonary bypass (CPB) (T3), the FCD was still significantly depressed in both treatment groups (153.5 ± 14.6 cm/cm² in the CECC group, P <0.05 vs 'T1'; 159.5 ± 12.4 cm/cm² in the MECC group, P <0.05 versus 'T1'). After termination of CPB (T4), the FCD recovered in both groups to baseline values. Microvascular blood flow velocity tended to remain at a higher level in the MECC group, whereas haemodilution during CPB was significantly reduced in the MECC group. The use of MECC in AVR did not affect procedural safety and, resulted in beneficial preservation of microvascular blood flow velocity and significantly reduced haemodilution during CPB. In contrast to CABG surgery, the use of MECC did not improve FCD during surgical AVR. Clinical advantages possibly resulting from attenuated haemodilution and preservation of microvascular blood flow velocity require further validation in larger patient cohorts. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Bonvini, S; Wassermann, V; Menegolo, M; Scrivere, P; Grego, F; Piazza, M
2015-08-01
Conversion of a previous endovascular aneurysm repair (EVAR) with suprarenal fixation is a challenging situation even in the elective setting. The outcomes of a technique based on preservation of the first proximal covered stent of the endograft, used as a "neo-neck" for proximal anastomosis, are presented. From 2001 to 2014, nine patients underwent elective conversion of a previous suprarenally fixed EVAR. After supraceliac clamping, the aneurysm sac was opened and the endograft identified; the fabric was cut beyond the first covered stent together with its native aortic wall in order to create a "neo-neck." An aortic balloon was inflated into the visceral aorta to avoid back bleeding. A Dacron bifurcated tube graft (Intergard, Maquet) was then sutured to the neo-neck mimicking endobanding, passing the stitches into the aortic wall and the first covered stent. The mean age was 68 years (range, 52-84 years). The stent grafts removed were four Zenith (Cook Medical), three Endurant (Medtronic), and two E-vita (Jotec). The indication for conversion was type 1A (n = 2), type 2 (n = 2), and type 3 (n = 1) endoleak, complete endograft thrombosis (n = 2), and abdominal pain with sac enlargement with no radiological sign of endoleak (n = 2). Blood loss was 1,428 mL (range 500-3,000 mL); the visceral ischemic time to perform the proximal anastomosis was 23.5 min ± 2.3 min). The post-operative complication rate was 11% (n = 1/9) related to a case of sac wall bleeding requiring re-intervention; mortality at 30 days was 0%. At 22 months (range, 8-41) the computed tomography angiogram demonstrated no signs of leaks or anastomotic pseudoaneurysm. Preservation of the proximal covered stent of an endograft with suprarenal fixation used as an infrarenal "neo-neck" with incorporation of the aorta to the suture line during elective surgical explantation simplifies the procedure, and can be achieved with very low early morbidity and mortality; furthermore, it seems to be durable over mid-term follow up. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.
Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang
2014-06-01
Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.
Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis
Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang
2014-01-01
Objective: Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. Methods: One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. Results: ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Conclusions: Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival. PMID:24903989
Decrease of total antioxidant capacity during coronary artery bypass surgery.
Kunt, Alper Sami; Selek, Sahbettin; Celik, Hakim; Demir, Deniz; Erel, Ozcan; Andac, Mehmet Halit
2006-09-01
Cardiac surgery induces an oxidative stress, which may lead to impairment of cardiac function. In this study, we aimed to measure the changes of oxidative and antioxidative status of patients undergoing coronary artery bypass surgery (CABG). We studied 79 patients who underwent CABG with and without cardiopulmonary bypass (CPB). Of the 79 patients, 39 had CPB and 40 did not. Blood samples were drawn before, during, and after the surgery. Antioxidant status was evaluated by measuring total antioxidant capacity (TAC), and oxidative status was evaluated by measuring total peroxide (TP) levels and oxidative stress index (OSI). TP and OSI levels increased, while TAC decreased progressively after the beginning of surgery, for all patients. There were negative correlations between TAC levels and aortic cross-clamping period and anastomosis time ( r = -0.553, p < 0.001 and r = -0.500, p < 0.001, respectively). In addition, there was a positive correlation between TAC and ejection fraction (r = 0.647, p < 0.001). During CABG, oxidant and OSI levels significantly increase and TAC significantly decreases. This situation is influenced by long CPB and anastomosis time, and also by low ventricular ejection fraction. We concluded that the patients who undergo CABG are exposed to potent oxidative stress that impairs their TAC. We speculate that supplementation with antioxidant vitamins such as vitamins C and E may be beneficial for patients undergoing CABG.
Impact of coronary artery bypass grafting in elderly patients.
Aikawa, Priscila; Cintra, Angélica Rossi Sartori; Leite, Cleber Aparecido; Marques, Ricardo Henrique; da Silva, Claudio Tafarel Mackmillan; Afonso, Max dos Santos; Paulitsch, Felipe da Silva; Oss, Evandro Augusto
2013-03-01
To analyze the results of isolated on-pump coronary artery bypass graft surgery (CABG) in patients > 65 years-old. Patients undergoing isolated on-pump CABG from December 1st 2010 to July 31th 2012 were divided in two groups: GE (elderly > 65 years-old, n=103) and GA (adults < 65 years-old, n=150). Preoperative data, intraoperative (as cardiopulmonar bypass time, aortic clamping time, time length of stay in mechanical ventilation--MV--and number of grafts), and postoperative variable (as morbidity, mortality and time length of stay in hospital) were analyzed during hospitalization. In GE, the morbidity rate was greater than in GA (30% vs. 14%, P=0.004), but there was no difference in the mortality rate (5.8% vs. 2.0%, P=0.165). In GA, there was higher prevalence DM (39.6% vs. 27%, P=0.043) and smoking (32.2% versus 19.8%, P=0.042); and in GE, higher prevalence of stroke (17% vs. 6.7%, P=0.013). There was no difference between the groups regarding intraoperative variables. After multivariate analysis, age > 65-year-old was associated with greater morbidity, but it was not independent predictive factor for in-hospital mortality. Considering in-hospital mortality, stay in ward time length (P=0.006), cardiac (P=0.011) and respiratory complications (P=0.026) were independent predictive factors. This study suggests that patients > 65-year old were at increased risk of postoperative complications when submitted to isolated on-pump CABG in comparison to patients < 65-year-old, but not under increased risk of death.
Chen, Ming; Luo, Huai; Miyamoto, Takashi; Atar, Shaul; Kobal, Sergio; Rahban, Masoud; Brasch, Andrea V; Makkar, Rajendra; Neuman, Yoram; Naqvi, Tasneem Z; Tolstrup, Kirsten; Siegel, Robert J
2003-09-01
We assessed aortic regurgitation (AR) severity by utilizing multiple echo-Doppler variables in comparison with AR severity by aortic root angiography. Patients were divided into 3 groups: mild, moderate, and severe. An AR index (ARI) was developed, comprising 5 echocardiographic parameters: ratio of color AR jet height to left ventricular outlet flow diameter, AR signal density from continuous-wave Doppler, pressure half-time, left ventricular end-diastolic diameter, and aortic root diameter. There was a strong correlation between AR severity by angiography and the calculated echo-Doppler ARI (r = 0.84, p = 0.0001). As validated by aortic angiography, the ARI is an accurate reflection of AR severity.
Timing of clamping and factors associated with iron stores in full-term newborns
Oliveira, Fabiana de Cássia Carvalho; Assis, Karine Franklin; Martins, Mariana Campos; do Prado, Mara Rúbia Maciel Cardoso; Ribeiro, Andréia Queiroz; Sant’Ana, Luciana Ferreira da Rocha; Priore, Silvia Eloiza; Franceschini, Sylvia do Carmo Castro
2014-01-01
OBJECTIVE To analyze the impact of timing of clamping and obstetric, biological and socioeconomic factors on the iron stores of full-term newborns. METHODS Cross-sectional study between October 2011 and July 2012 in which hematological parameters were evaluated for newborns in Viçosa, MG, Southeastern Brazil. It involved collecting 7 mL of umbilical cord blood from 144 full-term not underweight newborns. The parameters investigated were complete blood count, serum iron, ferritin and C-reactive protein. The time of umbilical cord clamping was measured using a digital timer without interfering in the procedures of childbirth. The birth data were collected from Live Birth Certificates and other information was obtained from the mother through a questionnaire applied in the first month postpartum. Analysis of multiple linear regression was then used to estimate the influence of biological, obstetrics and socioeconomic factors on the ferritin levels at birth. RESULTS The median ferritin was 130.3 µg/L (n = 129, minimum = 16.4; maximum = 420.5 µg/L), the mean serum iron was 137.9 μg/dL (n = 144, SD = 39.29) and mean hemoglobin was 14.7 g/dL (n = 144, SD = 1.47). The median time of cord clamping was 36 seconds, ranging between 7 and 100. The bivariate analysis detected an association between ferritin levels and color of the child, timing clamping of 60 seconds, type of delivery, the presence of gestational diabetes and per capita family income. In multivariate analysis, the variables per capita income, number of antenatal visits and length at birth accounted for 22.0% of variation in ferritin levels. CONCLUSIONS Iron stores at birth were influenced by biological, obstetric and social characteristics. Tackling anemia should involve creating policies aimed at reducing social inequalities, improving the quality of antenatal care, as well as implementing a criterion of delayed clamping of the umbilical cord within the guidelines of labor. PMID:24789632
Piezoresistive cantilever force-clamp system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L.
2011-04-15
We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to amore » sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.« less
Effect of picroside II on hind limb ischemia reperfusion injury in rats
Kılıç, Yiğit; Özer, Abdullah; Tatar, Tolga; Zor, Mustafa Hakan; Kirişçi, Mehmet; Kartal, Hakan; Dursun, Ali Doğan; Billur, Deniz; Arslan, Mustafa; Küçük, Ayşegül
2017-01-01
Introduction Many structural and functional damages are observed in cells and tissues after reperfusion of previously viable ischemic tissues. Acute ischemia reperfusion (I/R) injury of lower extremities occurs especially when a temporary cross-clamp is applied to the abdominal aorta during aortic surgery. Research regarding the treatment of I/R injury has been increasing day-by-day. In this study, we aimed to investigate the effect of picroside II on skeletal muscle of rats experiencing simulated I/R. Materials and methods Twenty-four male Wistar albino rats weighing between 210 and 300 g were used in this study. Rats were randomly divided into 4 groups of 6 rats each (control, I/R, control + picroside II, and I/R + picroside II). The infrarenal section of the abdominal aorta was occluded with an atraumatic microvascular clamp in I/R group. The clamp was removed after 120 minutes and reperfusion was provided for a further 120 minutes. Picroside II (10 mg kg−1) was administered intraperitoneally to the animals in control + picroside II and I/R + picroside II groups. At the end of the study, skeletal muscle tissue was obtained for the determination of total oxidant status (TOS) and total antioxidant status (TAS) levels. Apoptosis was evaluated by TUNEL experiment. Results TOS levels were significantly higher in I/R group than that of control and I/R + picroside II groups (P=0.014, P=0.005, respectively). TAS levels were significantly higher in I/R group than that of control and I/R + picroside II groups (P=0.007 P=0.005, respectively). TUNEL assay revealed that picroside II reduced cell necrosis. Conclusion The results of this study demonstrated that picroside II plays a critical role to prevent I/R injury. Even though our results were found to be satisfactory, it should be encouraging to those who want to conduct future research on this topic. PMID:28721011
Early and late outcomes of 1000 minimally invasive aortic valve operations.
Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F
2008-04-01
Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.
Surgical treatment of pararenal aortic aneurysms in the elderly.
Illuminati, G; D'Urso, A; Ceccanei, G; Caliò, F; Vietri, F
2007-12-01
Until fenestrated endografts will become the standard treatment of pararenal aortic aneurysms, open surgical repair will currently be employed for the repair of this condition. Suprarenal aortic control and larger surgical dissection represent additional technical requirements for the treatment of pararenal aneurysms compared to those of open infrarenal aortic aneurysms, which may be followed by an increased operative mortality and morbidity rate. As this may be especially true when dealing with pararenal aneurysms in an elderly patients' population, we decided to retrospectively review our results of open pararenal aortic aneurysm repair in elderly patients, in order to compare them with those reported in the literature. Twenty-one patients over 75 years of age were operated on for pararenal aortic aneurysms in a ten-year period. Exposure of the aorta was obtained by means of a retroperitoneal access, through a left flank incision on the eleventh rib. When dealing with interrenal aortic aneurysm the left renal artery was revascularized with a retrograde bypass arising from the aortic graft, proximally bevelled on the ostium of the right renal artery. Two patients died of acute intestinal ischemia, yielding a postoperative mortality of 9.5%. Nonfatal complications included 2 pleural effusions, a transitory rise in postoperative serum creatinine levels in 3 cases, and one retroperitoneal hematoma. Mean renal ischemia time was 23 min, whereas mean visceral ischemia time was 19 min. Mean inhospital stay was 11 days. Pararenal aortic aneurysms in the elderly can be surgically repaired with results that are similar to those obtained in younger patients.
Qin, Qingquan; Xu, Feng; Cao, Yongqing; Ro, Paul I; Zhu, Yong
2012-08-20
The effect of clamping on resonance frequency and thus measured Young's modulus of nanowires (NWs) is systematically investigated via a combined experimental and simulation approach. ZnO NWs are used in this work as an example. The resonance tests are performed in situ inside a scanning electron microscope and the NWs are cantilevered on a tungsten probe by electron-beam-induced deposition (EBID) of hydrocarbon. EBID is repeated several times to deposit more hydrocarbons at the same location. The resonance frequency increases with the increasing clamp size until approaching that under the "fixed" boundary condition. The critical clamp size is identified as a function of NW diameter and NW Young's modulus. This work: 1) exemplifies the importance of considering the effect of clamping in measurements of Young's modulus using the resonance method, and 2) demonstrates that the true Young's modulus can be measured if the critical clamp size is reached. Design guidelines on the critical clamp size are provided. Such design guidelines can be extended to other one-dimensional nanostructures such as carbon nanotubes. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ciubotariu, Rodica; Scaradavou, Andromachi; Ciubotariu, Ilinca; Tarnawski, Michal; Lloyd, Sara; Albano, Maria; Dobrila, Ludy; Rubinstein, Pablo; Grunebaum, Amos
2018-03-25
Cord blood (CB) is a widely accepted stem cell source and its clinical utilization depends, to a great extent, on its cell content. Birth-to-clamping (BTC) time of umbilical cord determines placental transfusion to the newborn, and the remaining blood that can be collected and banked. The 2017 Committee Opinion of the American College of Obstetrics and Gynecologists (ACOG) recommends a delay of "at least 30-60 seconds" before clamping the cord for all newborns to ensure adequate iron stores. The impact of delayed cord clamping (DCC) on public CB banking can be substantial. Cord blood units (CBUs) collected from 1210 mothers at one hospital were evaluated for total nucleated cells (TNCs) and weight/volume based on time to clamping. Bank staff recorded BTC time in seconds as reported by obstetricians; collections were performed ex utero. Immediate clamping was defined as BTC of less than 30 seconds, whereas DCC was defined as BTC of 30 seconds or more. Cord clamping was immediate in 903 (75%) and delayed in 307 (25%) deliveries. Successful recovery (% clinical CBUs) decreased 10-fold with DCC of more than 60 seconds (22% vs. 2.4%, p < 0.001). CBUs collected after DCC of more than 60 seconds had significantly lower TNC counts than those after DCC of less than 60 seconds (p < 0.0001). Furthermore, 38% to 46% of CBUs after DCC of more than 60 seconds had volume of less than 40 mL. Our study indicates that DCC of 30 to 60 seconds has a small negative impact on collection of high-TNC-count CBUs. However, increasing BTC to more than 60 seconds decreases significantly both TNC content and volume, reducing drastically the chances of obtaining clinically useful CBUs. © 2018 AABB.
Outcomes After Operations for Unicuspid Aortic Valve With or Without Ascending Repair in Adults
Zhu, Yuanjia; Roselli, Eric E.; Idrees, Jay J.; Wojnarski, Charles M.; Griffin, Brian; Kalahasti, Vidyasagar; Pettersson, Gosta; Svensson, Lars G.
2016-01-01
Background Unicuspid aortic valve is an important subset of bicuspid aortic valve, and knowledge regarding its aortopathy pattern and surgical outcomes is limited. Our objectives were to characterize unicuspid aortic valve patients, associated aortopathy, and surgical outcomes. Methods From January 1990 to May 2013, 149 adult unicuspid aortic valve patients underwent aortic valve replacement or repair for aortic stenosis (n = 13), regurgitation (n = 13), or both (n = 123), and in 91 (61%) the aortic valve operation was combined with aortic repair. Data were obtained from the Cardiovascular Information Registry and medical record review. Three-dimensional imaging analysis was performed from preoperative computed tomography and magnetic resonance imaging scans. The Kaplan-Meier method was used for survival analysis. Results Patients had a mean maximum aortic diameter of 44 ± 8 mm and variably involved the aortic root, ascending, or arch, or both. Patients with valve operations alone were more likely to be hypertensive (p = 0.01) and to have severe aortic stenosis (p = 0.07) than those who underwent concurrent aortic operations. There were no operative deaths, strokes, or myocardial infarctions. Patients undergoing aortic repair had better long-term survival. Estimated survival at 1, 5, and 10 years was 100%, 100%, and 100% after combined operations and was 100%, 88%, and 88% after valve operations alone (p = 0.01). Conclusions Patients with a dysfunctional unicuspid aortic valve frequently present with an ascending aneurysm that requires repair. Combined aortic valve operations and aortic repair was associated with significantly better long-term survival than a valve operation alone. Further study of this association may direct decisions about timing of surgical intervention. PMID:26453423
Wojakowski, W; Gminski, J; Siemianowicz, K; Goss, M; Machalski, M
2001-03-01
Aortic elastin turnover is significantly accelerated in atherosclerosis, partly because of activation of the renin-angiotensin-aldosterone system caused by hypercholesterolaemia. We postulated that angiotensin-converting enzyme inhibitors (ACE-I) prevent the aortic elastin loss in experimental hypercholesterolaemia. Two doses of ACE-I (captopril, enalapril and quinapril) were used: a dose equivalent to that applied to human subjects and a dose 10 times higher. We found that the increase in serum and aortic elastolytic activity in cholesterol-fed rabbits was prevented by high-dose captopril. The elastin content in aorta homogenates from cholesterol-fed rabbits was significantly decreased. The higher dose of captopril, but no other ACE-I, prevented this decrease in aortic elastin content. In cholesterol-fed rabbits the elastin-bound calcium content was significantly elevated. The higher doses of captopril and enalapril lowered the elastin-bound calcium content. In serum and aortic homogenates of cholesterol-fed rabbits, ACE activity was elevated by 15% and 77%, respectively. Both doses of captopril, enalapril and quinapril prevented this cholesterol-induced increase in serum and aortic ACE activity. We conclude that: 1) administration of captopril at doses 10 times higher than those used in humans prevents hypercholesterolaemia increased aortic elastin loss. 2) higher doses of captopril and enalapril prevent the hypercholesterolaemia-induced increase in aortic elastin-bound calcium.
Management of umbilical cord clamping.
Webbon, Lucy
2013-02-01
The Royal College of Midwives (RCM) has updated its third stage of labour guidelines (RCM 2012) to be clearly supportive of a delay in umbilical cord clamping, although specific guidance on timing is yet to be announced. It is therefore imperative that both midwives and student midwives understand and are able to integrate delaying into their practice, as well as communicating to women the benefits; only in this way can we give women fully informed choices on this aspect of care. The main benefit of delayed cord clamping is the protection it can provide in reducing childhood anaemia, which is a major issue, especially in poorer countries. A review of the evidence found no risks linked to delayed clamping, and no evidence that it cannot be used in combination with the administration of uterotonic drugs. Delayed cord clamping can be especially beneficial for pre term and compromised babies.
Cruz, Cristina; Pinho, Teresa; Lebreiro, Ana; Silva Cardoso, José; Maciel, Maria Júlia
2013-06-01
Transthoracic echocardiography is an important tool after tetralogy of Fallot repair, of which aortic root dilatation is a recognized complication. In this study we aimed to assess its prevalence and potential predictors. We consecutively assessed adult patients by transthoracic echocardiography after tetralogy of Fallot repair, and divided them into two groups based on the maximum internal aortic diameter at the sinuses of Valsalva in parasternal long-axis view: group 1 with aortic root dilatation (≥38 mm) and group 2 without dilatation (<38 mm). A total of 53 patients were included, mean age 32±10 years, with a mean time since surgery of 23±7 years. An aortopulmonary shunt had been performed prior to complete repair in 25 patients, and a transannular patch was used in 19 patients. Aortic root measurement was possible in all patients. Aortic root dilatation was identified in eight patients (15%), all male. Male gender (p=0.001), body surface area (1.93±0.10 vs. 1.70±0.20 m(2), p=0.03) and increased left ventricular end-diastolic diameter (p=0.005) were predictors of aortic root dilatation. None of the surgical variables studied were predictors of aortic root dilatation. The prevalence of aortic root dilatation in this cohort was low and male gender was a predictor of its occurrence. The type of repair and time to surgery did not influence its occurrence. Quantification of aortic root diameter is possible by transthoracic echocardiography; we suggest indexing it to body surface area in clinical practice. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Aortic blood pressure measured via EIT: investigation of different measurement settings.
Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe
2015-06-01
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.
Load dependence of the effective regurgitant orifice area in a sheep model of aortic regurgitation.
Reimold, S C; Byrne, J G; Caguioa, E S; Lee, C C; Laurence, R G; Peigh, P S; Cohn, L H; Lee, R T
1991-10-01
Treatment of patients with aortic regurgitation with vasodilators reduces regurgitant volume, ventricular dilation and left ventricular mass. Although these effects are presumably due to afterload reduction, it is also possible that the aortic regurgitant orifice area is not constant. To test the latter hypothesis, aortic regurgitation was created in 10 open chest sheep by partial resection of the noncoronary leaflet under direct visualization. Regurgitant flow was measured with an aortic supravalvular electromagnetic probe; aortic and left ventricular pressures were measured with catheter-tipped micromanometer pressure transducers. The effective regurgitant orifice area was calculated by a modification of the continuity equation in a manner similar to the Gorlin equation. The regurgitant orifice area was measured three times: after aortic regurgitation was created, after mean arterial pressure was increased by 15 to 25 mm Hg with intravenous dopamine and after mean arterial pressure was reduced by 15 to 25 mm Hg with intravenous sodium nitroprusside. Comparison of regurgitant volumes and areas obtained after creation of aortic regurgitation and at the conclusion of the experiment in the absence of dopamine or sodium nitroprusside demonstrated no significant change over time. Dopamine administration was associated with an 86 +/- 81% increase in regurgitant volume (p less than 0.01) and a 38 +/- 44% increase in regurgitant orifice area (p less than 0.01). Sodium nitroprusside administration resulted in a 51 +/- 14% decrease in regurgitant volume (p less than 0.001) and a 28 +/- 21% reduction in regurgitant orifice area (p = 0.007). In this model of acute aortic regurgitation, the effective regurgitant orifice area was altered by increasing or decreasing the aortic transvalvular pressure gradient.(ABSTRACT TRUNCATED AT 250 WORDS)
Li, Pu; Qin, Chao; Cao, Qiang; Li, Jie; Lv, Qiang; Meng, Xiaoxin; Ju, Xiaobing; Tang, Lijun; Shao, Pengfei
2016-10-01
To evaluate the feasibility and efficiency of laparoscopic partial nephrectomy (LPN) with segmental renal artery clamping, and to analyse the factors affecting postoperative renal function. We conducted a retrospective analysis of 466 consecutive patients undergoing LPN using main renal artery clamping (group A, n = 152) or segmental artery clamping (group B, n = 314) between September 2007 and July 2015 in our department. Blood loss, operating time, warm ischaemia time (WIT) and renal function were compared between groups. Univariable and multivariable linear regression analyses were applied to assess the correlations of selected variables with postoperative glomerular filtration rate (GFR) reduction. Volumetric data and estimated GFR of a subset of 60 patients in group B were compared with GFR to evaluate the correlation between these functional variables and preserved renal function after LPN. The novel technique slightly increased operating time, WIT and intra-operative blood loss (P < 0.001), while it provided better postoperative renal function (P < 0.001) compared with the conventional technique. The blocking method and tumour characteristics were independent factors affecting GFR reduction, while WIT was not an independent factor. Correlation analysis showed that estimated GFR presented better correlation with GFR compared with kidney volume (R(2) = 0.794 cf. R(2) = 0.199) in predicting renal function after LPN. LPN with segmental artery clamping minimizes warm ischaemia injury and provides better early postoperative renal function compared with clamping the main renal artery. Kidney volume has a significantly inferior role compared with eGFR in predicting preserved renal function. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
McElhinney, Doff B; Lacro, Ronald V; Gauvreau, Kimberlee; O'Brien, Cheryl M; Yaroglu Kazanci, Selcen; Vogel, Melanie; Emani, Sitaram; Brown, David W
2012-09-01
Dilation of the ascending aorta (AA) is common in patients with a bicuspid aortic valve. The natural history of the aortic root and AA and the risk factors for dilation have not been characterized in patients with congenital aortic stenosis (AS) treated with balloon valvuloplasty during childhood. The present study was performed to determine the prevalence of aortic dilation in patients with congenital AS before and up to 20 years after balloon valvuloplasty performed during childhood. In patients who underwent balloon valvuloplasty for AS at age ≤ 18 years from 1984 to 2005, the aortic diameter measurements before intervention and at 5-year intervals afterward were recorded and the Z scores calculated. Among 156 patients (median age 1.5 years at valvuloplasty), the AA Z scores were significantly larger than normal before intervention (median Z score 1.5) and at all follow-up points (all p <0.001). Using mixed modeling, with time as a categorical variable (before intervention, 5-year window, 10-year window, and so forth), the mean AA Z score was greater at all postvalvuloplasty points than before the intervention, with mean Z score increases of 1.20 at 5 years and 2.11 at 20 years (p <0.001). Moderate or greater aortic regurgitation early after valvuloplasty was associated with greater AA Z scores than mild or less aortic regurgitation, with a progressive difference over time. More significant residual AS after valvuloplasty was associated with lower AA Z scores over time. In conclusion, AA dilation is common in children with congenital AS and continues to progress over many years after balloon valvuloplasty. Copyright © 2012 Elsevier Inc. All rights reserved.
Hughes, William E; Ueda, Kenichi; Treichler, David P; Casey, Darren P
2016-09-30
Aging is associated with elevated blood pressure (peripheral and aortic; BP) and aortic augmentation index (AIx) which may contribute to aortic BP. Although inorganic nitrate consumption reduces peripheral BP in both young and older adults, the effects of nitrate consumption on aortic BP and wave reflection in young and older adults is unknown. Therefore, we sought to characterize the effects of nitrate consumption on aortic BP and AIx in young and older adults. Noninvasive aortic pressure waveforms were synthesized from high-fidelity radial pressure waveforms via applanation tonometry before and following (60, 90, 120, 150, and 180 min) consumption of a nitrate-rich beetroot juice in 26 healthy adults (young: 25 ± 4 years, n = 14; older: 64 ± 5 years, n = 12). Aortic BP and indices of aortic wave reflection (AIx and AIx normalized for heart rate; AIx@75bpm) were calculated from the generated aortic pressure waveform. Nitrate consumption increased plasma nitrite in both groups 60-180 min following beetroot consumption (P < 0.001). Nitrate consumption reduced peripheral and aortic BP in both young and older adults (P < 0.05), with the change being similar between age groups. Conversely, indices of aortic wave reflection were reduced only in young adults following nitrate consumption (range of change from baseline over time: AIx@75bpm, -4.3 to -8.8%, P < 0.05), whereas aortic AIx remained unchanged in the older adults. Taken together, our results suggest that acute dietary nitrate supplementation reduces peripheral and aortic BP similarly in young and older adults despite differential effects on aortic AIx between age groups. Copyright © 2016 Elsevier Inc. All rights reserved.
Lee Henry, Christopher; Ko, Jong Mi; Henry, Albert Carl; Matter, Gregory John
2011-01-01
Aortic valve replacement following an earlier coronary artery bypass grafting (CABG) procedure is fairly common. When this situation occurs, the type of valve dysfunction is usually stenosis (with or without regurgitation), and whether it was missed at the time of the earlier CABG or developed subsequently is usually unclear. We attempted to determine the survival in patients who had had aortic valve replacement after 2 previous CABG procedures. We describe 12 patients who had aortic valve replacement for aortic stenosis; rather than one previous CABG operation, all had had 2 previous CABG procedures. Only one patient died in the early postoperative period after aortic valve replacement, and the remaining 11 were improved substantially: all have lived at least 11 months, and one is still alive at over 101 months after aortic valve replacement. Aortic valve replacement remains beneficial for most patients even after 2 previous CABG procedures. PMID:21307968
Randomized clinical trial of stapler versus clamp-crushing transection in elective liver resection.
Rahbari, N N; Elbers, H; Koch, M; Vogler, P; Striebel, F; Bruckner, T; Mehrabi, A; Schemmer, P; Büchler, M W; Weitz, J
2014-02-01
Various devices have been developed to facilitate liver transection and reduce blood loss in liver resections. None of these has proven superiority compared with the classical clamp-crushing technique. This randomized clinical trial compared the effectiveness and safety of stapler transection with that of clamp-crushing during open liver resection. Patients admitted for elective open liver resection between January 2010 and October 2011 were assigned randomly to stapler transection or the clamp-crushing technique. The primary endpoint was the total amount of intraoperative blood loss. Secondary endpoints included transection time, duration of operation, complication rates and resection margins. A total of 130 patients were enrolled, 65 to clamp-crushing and 65 to stapler transection. There was no difference between groups in total intraoperative blood loss: median (i.q.r.) 1050 (525-1650) versus 925 (450-1425) ml respectively (P = 0·279). The difference in total intraoperative blood loss normalized to the transection surface area was not statistically significant (P = 0·092). Blood loss during parenchymal transection was significantly lower in the stapler transection group (P = 0·002), as were the parenchymal transection time (mean(s.d.) 30(21) versus 9(7) min for clamp-crushing and stapler transection groups respectively; P < 0·001) and total duration of operation (mean(s.d.) 221(86) versus 190(85) min; P = 0·047). There were no significant differences in postoperative morbidity (P = 0·863) or mortality (P = 0·684) between groups. Stapler transection is a safe technique but does not reduce intraoperative blood loss in elective liver resection compared with the clamp-crushing technique. NCT01049607 (http://www.clinicaltrials.gov). © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.
Repair of aorto-left ventricular tunnel arising from the left sinus of valsalva.
Nezafati, Mohammad Hassan; Maleki, Mahmood Hosseinzadeh; Javan, Hadi; Zirak, Nahid
2010-05-01
Aortico-left ventricular tunnel (ALVT) is a rare congenital cardiac defect that bypasses the aortic valve via a para-valvular connection from the left ventricle to the aorta. In most cases, the tunnel arises from the right aortic sinus. In this case report, we are presenting a case of ALVT, of which the aortic orifice arose from the left aortic sinus, requiring special attention to avoid the left coronary artery injury at the time of surgical repair.
[Non-invasive estimation of aortic flow by local electrical impedance changes].
Okuda, N; Ohashi, N; Yamada, M; Fujinami, T
1986-09-01
Aortic flow velocity was measured by catheter-tip flow transducer in 25 patients who underwent left cardiac catheterization for non-invasive estimates by the impedance method. Disk electrodes were attached to the skin at the levels of the second thoracic vertebra in the posterior median line and the V8 lead position for electrocardiography. Alternating current, 350 micro-amperes, 50 KHz constant, was applied to the outer electrode, and impedance changes were detected via the inner electrode. The e wave, or height of the first derivative dz/dt wave of the electrical impedance was lower in cases of old myocardial infarction and higher in cases of aortic valve regurgitation, as compared with the values of the healthy control group. The time lag between the start of the upward deflection and the peak value of the dz/dt wave coincided with that of the aortic flow curve as measured at the aortic arch and descending aorta. These time lags were about 20 to 30 msec as compared with the ascending aortic flow curve, and were -20 to -30 msec as compared with the abdominal aortic flow curve. There was a close correlation between the maximum flow velocity measured at the aortic arch and the height of the e waves. The regression equation was: Y = 0.21X - 1.53, r = 0.88, p less than 0.01. These data suggest that the first derivative of electrical impedance change as obtained by the disk electrode method reflects aortic flow at the arch and descending aorta.
Williams, Christopher R; Brooke, Benjamin S
2017-10-01
Patient outcomes after open abdominal aortic aneurysm and endovascular aortic aneurysm repair have been widely reported from several large, randomized, controlled trials. It is not clear whether these trial outcomes are representative of abdominal aortic aneurysm repair procedures performed in real-world hospital settings across the United States. This study was designed to evaluate population-based outcomes after endovascular aortic aneurysm repair versus open abdominal aortic aneurysm repair using statewide inpatient databases and examine how they have helped improve our understanding of abdominal aortic aneurysm repair. A systematic search of MEDLINE, EMBASE, and CINAHL databases was performed to identify articles comparing endovascular aortic aneurysm repair and open abdominal aortic aneurysm repair using data from statewide inpatient databases. This search was limited to studies published in the English language after 1990, and abstracts were screened and abstracted by 2 authors. Our search yielded 17 studies published between 2004 and 2016 that used data from 29 different statewide inpatient databases to compare endovascular aortic aneurysm repair versus open abdominal aortic aneurysm repair. These studies support the randomized, controlled trial results, including a lower mortality associated with endovascular aortic aneurysm repair extended from the perioperative period up to 3 years after operation, as well as a higher complication rate after endovascular aortic aneurysm repair. The evidence from statewide inpatient database analyses has also elucidated trends in procedure volume, patient case mix, volume-outcome relationships, and health care disparities associated with endovascular aortic aneurysm repair versus open abdominal aortic aneurysm repair. Population analyses of endovascular aortic aneurysm repair and open abdominal aortic aneurysm repair using statewide inpatient databases have confirmed short- and long-term mortality outcomes obtained from large, randomized, controlled trials. Moreover, these analyses have allowed us to assess the effect of endovascular aortic aneurysm repair adoption on population outcomes and patient case mix over time. Published by Elsevier Inc.
Aortic events in a nationwide Marfan syndrome cohort.
Groth, Kristian A; Stochholm, Kirstine; Hove, Hanne; Kyhl, Kasper; Gregersen, Pernille A; Vejlstrup, Niels; Østergaard, John R; Gravholt, Claus H; Andersen, Niels H
2017-02-01
Marfan syndrome is associated with morbidity and mortality due to aortic dilatation and dissection. Preventive aortic root replacement has been the standard treatment in Marfan syndrome patients with aortic dilatation. In this study, we present aortic event data from a nationwide Marfan syndrome cohort. The nationwide cohort of Danish Marfan syndrome patients was established from the Danish National Patient Registry and the Cause of Death Register, where we retrieved information about aortic surgery and dissections. We associated aortic events with age, sex, and Marfan syndrome diagnosis prior or after the first aortic event. From the total cohort of 412 patients, 150 (36.4 %) had an aortic event. Fifty percent were event free at age 49.6. Eighty patients (53.3 %) had prophylactic surgery and seventy patients (46.7 %) a dissection. The yearly event rate was 0.02 events/year/patient in the period 1994-2014. Male patients had a significant higher risk of an aortic event at a younger age with a hazard ratio of 1.75 (CI 1.26-2.42, p = 0.001) compared with women. Fifty-three patients (12.9 %) were diagnosed with MFS after their first aortic event which primarily was aortic dissection [n = 44 (83.0 %)]. More than a third of MFS patients experienced an aortic event and male patients had significantly more aortic events than females. More than half of the total number of dissections was in patients undiagnosed with MFS at the time of their event. This emphasizes that diagnosing MFS is lifesaving and improves mortality risk by reducing the risk of aorta dissection.
Lieberg, J; Pruks, L-L; Kals, M; Paapstel, K; Aavik, A; Kals, J
2018-06-01
Abdominal aortic aneurysm is a degenerative vascular pathology with high mortality due to its rupture, which is why timely treatment is crucial. The current single-center retrospective study was undertaken to analyze short- and long-term all-cause mortality after operative treatment of abdominal aortic aneurysm and to examine the factors that influence outcome. The data of all abdominal aortic aneurysm patients treated with open repair or endovascular aneurysm repair in 2004-2015 were retrospectively retrieved from the clinical database of Tartu University Hospital. The primary endpoint was 30-day, 90-day, and 5-year all-cause mortality. The secondary endpoint was determination of the risk factors for mortality. Elective abdominal aortic aneurysm repair was performed on 228 patients (mean age 71.8 years), of whom 178 (78%) were treated with open repair and 50 (22%) with endovascular aneurysm repair. A total of 48 patients with ruptured abdominal aortic aneurysm were treated with open repair (mean age 73.8 years) at the Department of Vascular Surgery, Tartu University Hospital, Estonia. Mean follow-up period was 4.2 ± 3.3 years. In patients with elective abdominal aortic aneurysm, 30-day, 90-day, and 5-year all-cause mortality rates were 0.9%, 2.6%, and 32%, respectively. In multivariate analysis, the main predictors for 5-year mortality were preoperative creatinine value and age (p < 0.05). In patients with ruptured abdominal aortic aneurysm, 30-day, 90-day, and 5-year all-cause mortality rates were 22.9%, 33.3%, and 55.1%, respectively. In multivariate analysis, the risk factors for 30-day mortality in ruptured abdominal aortic aneurysm were perioperative hemoglobin and lactate levels (p < 0.05). According to this study, the all-cause mortality rates of elective abdominal aortic aneurysm and ruptured abdominal aortic aneurysm at our hospital were comparable to those at other centers worldwide. Even though some variables were identified as potential predictors of survival, the mortality rates after ruptured abdominal aortic aneurysm remain high. Early diagnosis, timely treatment, and detection of the risk factors for abdominal aortic aneurysm progression would improve survival in patients with abdominal aortic aneurysm.
Zhao, Liyun; Zhou, Sijie; Fan, Taibing; Li, Bin; Liang, Weijie; Dong, Haoju
2018-01-01
To assess the clinical value of three-dimensional (3D) printing technology for treatment strategies for complex double outlet right ventricle (DORV). Twenty-five patients with complex double outlet right ventricle were enrolled in this study. The patients were divided into two groups: 3D printing group (eight patients) and a non-3-D printing control group (17 patients). The cardiac images of patients in the 3D printing group were transformed to Digital Imaging and Communications and were segmented and reconstructed to create a heart model. No cardiac models were created in the control group. A Pearson coefficient analysis was used to assess the correlation between measurements of 3D printed models and computed tomography angiography (CTA) data. Pre-operative assessment and planning were performed with 3D printed models, and then operative time and recovery time were compared between the two groups. There was good correlation (r = 0.977) between 3D printed models and CTA data. Patients in the 3D printing group had shorter aortic cross-clamp time (102.88 vs 127.76 min, P = 0.094) and cardiopulmonary bypass time (151.63 vs 184.24 min; P = 0.152) than patients in the control group. Patients with 3D printed models had significantly lower mechanical ventilation time (56.43 vs 96.76 h, P = 0.040) and significantly shorter intensive care unit time (99.04 vs 166.94 h, P = 0.008) than patients in the control group. 3D printed models can accurately demonstrate anatomic structures and are useful for pre-operative treatment strategies in DORV. © 2018 Wiley Periodicals, Inc.
Early chest tube removal after coronary artery bypass graft surgery.
Mirmohammad-Sadeghi, Mohsen; Etesampour, Ali; Gharipour, Mojgan; Shariat, Zeinab; Nilforoush, Peyman; Saeidi, Mahmoud; Mackie, Mahsa; Sadeghi, Fatemeh Mirmohamad
2009-12-01
There is no clear data about the optimum time for chest tube removal after coronary artery bypass surgery. The aim of this study was to assess the impact of the chest tube removal time following coronary artery bypass grafting surgery on the clinical outcome of the patients. An analysis of data from 307 patients was performed. The patients were randomized into two groups: in group 1 (N=107) chest tubes were removed within the first 24 hours after surgery, whereas in group 2 (N=200), chest tubes were removed in the second 24 hours after surgery. Demographics, lactate and pH at the beginning, during and after the operation, creatinine, left ventricular ejection fraction, inotropic drugs administration, length of ICU stay, and mortality data were collected. Respiratory rate and pain level was assessed. In these surgeries, the mean± standard deviation for the aortic clamping time was 49.18±17.59 minutes and cardiopulmonary bypass time was 78.39±25.12 minutes. The amount of heparin consumed by the second group was higher (P <0.001) which could be considered as an important factor in increasing the drainage time after the surgery (P =0.047). The pain level evaluated 24 hours post-operation was lower in the first group, and the difference in the pain level between the 2 groups evaluated 30 hours post-operation was significant (P=0.016). The mean time of intensive care unit stay was longer in the second group but it was not statistically significant. Early extracting of chest tubes after coronary artery bypass graft surgery when there is no significant drainage can lead to pain reduction and consuming oxygen is an effective measure after surgery toward healing; it doesn't increase the risk of creation of plural effusion and pericardial effusion.
Uncu, Hasan; Acipayam, Mehmet; Altinay, Levent; Doğan, Pinar; Davarcı, Isil; Özsöyler, İbrahim
2014-01-01
Introduction In this retrospective study, we aimed to determine the risk factors for coronary artery bypass surgery in patients under 45 years of age, and evaluate the early postoperative results and the effect of gender. Methods A total of 324 patients under 45 years of age who undergone on-pump coronary artery bypass surgery between April 12, 2004 and January 10, 2012 were included to the study. Patients divided into groups as follows: Group 1 consisted of 269 males (mean age 41.3), Group 2 consisted of 55 females (mean age 41.6). Preoperative risk factors, intraoperative and postoperative data and early mortality rates of the groups were compared. Results Smoking rate was significantly higher in Group 1. Diabetes mellitus incidence and body mass index were significantly higher in Group 2 (P values P=0.01; P=0.0001; P=0.04 respectively). The aortic cross-clamping and cardiopulmonary bypass time and number of grafts per patient were significantly higher in Group 1 (P values P=0.04; P=0.04; P=0.002 respectively). There were no deaths in either group. Conclusion We found that gender has no effect on early mortality rates of the coronary bypass surgery patients under 45 years. PMID:25714211
Characteristics of 5-HT-containing chemoreceptor cells of the chicken aortic body
Ito, Shigeo; Ohta, Toshio; Nakazato, Yoshikazu
1999-01-01
Voltage-dependent and oxygen-sensitive currents in 5-HT-containing epithelioid cells isolated from chicken thoracic aorta were examined using the whole-cell patch clamp technique. 5-HT immunoreactive cells were identified with Neutral Red. The release of 5-HT from chicken thoracic aorta in the presence of excess KCl and veratridine was also examined using HPLC. At a holding potential of −70 mV with CsCl pipette solution, depolarizing steps between −30 and +60 mV produced inward currents that were blocked by tetrodotoxin (0.2 μm). In the presence of tetrodotoxin and BaCl2 (5 mm), depolarizing steps evoked slow inward currents that were sensitive to CoCl2 (2 mm). Nifedipine (1 μm) decreased the currents to 79.4 ± 1.7%, and ω-conotoxin GVIA (1 μm) to 20.2 ± 3.8%. When KCl pipette solution was used, depolarizing potentials positive to −40 mV caused outward currents that were inhibited by tetraethylammonium chloride. The K+ currents evoked by depolarizing steps to +20 mV were reduced to 90.3 ± 0.8% by hypoxia in five out of seven cells. Two cells failed to respond to hypoxia. The K+ current response was partly decreased by Neutral Red (20 μm). Excess KCl (60 mm) and veratridine (30 μm) both caused the release of 5-HT from aortic strips. 5-HT outputs induced by both stimuli were partly inhibited by nifedipine (1 μm) and by ω-conotoxin GVIA (1 μm), and were abolished by these drugs in combination and by extracellular Ca2+ removal. These results suggest that epithelioid cells containing 5-HT act as chemoreceptor cells in the chicken aortic body, having voltage-dependent Na+, K+, and L- and N-type Ca2+ channels, and oxygen-sensitive K+ channels. PMID:9925877
Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj
2015-01-01
Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05). Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.
Wohl, P; Krusinová, E; Klementová, M; Wohl, P; Kratochvílová, S; Pelikánová, T
2008-01-01
The hyperinsulinemic euglycemic clamp (HEC) combined with indirect calorimetry (IC) is used for estimation of insulin-stimulated substrate utilization. Calculations are based on urinary urea nitrogen excretion (UE), which is influenced by correct urine collection. The aims of our study were to improve the timing of urine collection during the clamp and to test the effect of insulin on UE in patients with type 1 diabetes (DM1; n=11) and healthy subjects (C; n=11). Urine samples were collected (a) over 24 h divided into 3-h periods and (b) before and during two-step clamp (1 and 10 mIU.kg(-1).min(-1); period 1 and period 2) combined with IC. The UE during the clamp was corrected for changes in urea pool size (UEc). There were no significant differences in 24-h UE between C and DM1 and no circadian variation in UE in either group. During the clamp, serum urea decreased significantly in both groups (p<0.01). Therefore, UEc was significantly lower as compared to UE not adjusted for changes in urea pool size both in C (p<0.001) and DM1 (p<0.001). While UE did not change during the clamp, UEc decreased significantly in both groups (p<0.01). UEc during the clamp was significantly higher in DM1 compared to C both in period 1 (p<0.05) and period 2 (p<0.01). The UE over 24 h and UEc during the clamp were statistically different in both C and DM1. We conclude that urine collection performed during the clamp with UE adjusted for changes in urea pool size is the most suitable technique for measuring substrate utilization during the clamp both in DM1 and C. Urine collections during the clamp cannot be replaced either by 24-h sampling (periods I-VII) or by a single 24-h urine collection. Attenuated insulin-induced decrease in UEc in DM1 implicates the impaired insulin effect on proteolysis.
Sabbagh, Robert; Chawla, Arun; Tisdale, Britton; Kwan, Kevin; Chatterjee, Suman; Kwiecien, Jacek M.; Kapoor, Anil
2011-01-01
Background Thirty minutes has been considered as the threshold for tolerable warm ischemic time (WIT). Recent reports demonstrate recovery of renal function after longer WIT. We assessed renal histology according to different WIT in a 2-kidney porcine model. Methods Twelve female pigs were randomized to an open or laparoscopic group. Each pig was further randomized within each group to clamping the left renal artery for 5, 15, 30, 45, 60 or 180 minutes. Preclamping left renal biopsies were performed on each pig. The contralateral kidney in each animal was used as an individual control. On postoperative day 14, all animals underwent bilateral nephrectomies. Preclamping left renal biopsies and all renal specimens were evaluated by a blinded veterinary pathologist. Results One pig died in the open group after 180 minutes of clamping. Histopathology did not show any significant changes between the two groups and across clamp times from 5 to 60 minutes. After 180 minutes of laparoscopic clamping, there was evidence of diffuse necrosis. Interpretation Sixty minutes of ischemia did not show any permanent renal damage in both groups. Further studies are needed to verify these findings in humans. A prolonged ischemic time without permanent renal damage would be helpful in partial nephrectomy. Warm ischemic time of 180 minutes exceeded the renal ischemic burden based on histological features. PMID:21470513
Mechanism of opening a sliding clamp
Douma, Lauren G.; Yu, Kevin K.; England, Jennifer K.
2017-01-01
Abstract Clamp loaders load ring-shaped sliding clamps onto DNA where the clamps serve as processivity factors for DNA polymerases. In the first stage of clamp loading, clamp loaders bind and stabilize clamps in an open conformation, and in the second stage, clamp loaders place the open clamps around DNA so that the clamps encircle DNA. Here, the mechanism of the initial clamp opening stage is investigated. Mutations were introduced into the Escherichia coli β-sliding clamp that destabilize the dimer interface to determine whether the formation of an open clamp loader–clamp complex is dependent on spontaneous clamp opening events. In other work, we showed that mutation of a positively charged Arg residue at the β-dimer interface and high NaCl concentrations destabilize the clamp, but neither facilitates the formation of an open clamp loader–clamp complex in experiments presented here. Clamp opening reactions could be fit to a minimal three-step ‘bind-open-lock’ model in which the clamp loader binds a closed clamp, the clamp opens, and subsequent conformational rearrangements ‘lock’ the clamp loader–clamp complex in a stable open conformation. Our results support a model in which the E. coli clamp loader actively opens the β-sliding clamp. PMID:28973453
Güvenç, Tolga Sinan; Karaçimen, Denizhan; Erer, Hatice Betül; İlhan, Erkan; Sayar, Nurten; Karakuş, Gültekin; Çekirdekçi, Elif; Eren, Mehmet
2015-01-01
Management of aortic regurgitation depends on the assessment for severity. Echocardiography remains as the most widely available tool for evaluation of aortic regurgitation. In this manuscript, we describe a novel parameter, jet length/velocity ratio, for the diagnosis of severe aortic regurgitation. A total of 30 patients with aortic regurgitation were included to this study. Severity of aortic regurgitation was assessed with an aortic regurgitation index incorporating five echocardiographic parameters. Jet length/velocity ratio is calculated as the ratio of maximum jet penetrance to mean velocity of regurgitant flow. Jet length/velocity ratio was significantly higher in patients with severe aortic regurgitation (2.03 ± 0.53) compared to patients with less than severe aortic regurgitation (1.24 ± 0.32, P < 0.001). Correlation of jet length/velocity ratio with aortic regurgitation index was very good (r(2) = 0.86) and correlation coefficient was higher for jet length/velocity ratio compared to vena contracta, jet width/LVOT ratio and pressure half time. For a cutoff value of 1.61, jet length/velocity ratio had a sensitivity of 92% and specificity of 88%, with an AUC value of 0.955. Jet length/velocity ratio is a novel parameter that can be used to assess severity of chronic aortic regurgitation. Main limitation for usage of this novel parameter is jet impringement to left ventricular wall. © 2014, Wiley Periodicals, Inc.
Hardman, David; Doyle, Barry J; Semple, Scott I K; Richards, Jennifer M J; Newby, David E; Easson, William J; Hoskins, Peter R
2013-10-01
In abdominal aortic aneurysm disease, the aortic wall is exposed to intense biological activity involving inflammation and matrix metalloproteinase-mediated degradation of the extracellular matrix. These processes are orchestrated by monocytes and rather than affecting the aorta uniformly, damage and weaken focal areas of the wall leaving it vulnerable to rupture. This study attempts to model numerically the deposition of monocytes using large eddy simulation, discrete phase modelling and near-wall particle residence time. The model was first applied to idealised aneurysms and then to three patient-specific lumen geometries using three-component inlet velocities derived from phase-contrast magnetic resonance imaging. The use of a novel, variable wall shear stress-limiter based on previous experimental data significantly improved the results. Simulations identified a critical diameter (1.8 times the inlet diameter) beyond which significant monocyte deposition is expected to occur. Monocyte adhesion occurred proximally in smaller abdominal aortic aneurysms and distally as the sac expands. The near-wall particle residence time observed in each of the patient-specific models was markedly different. Discrete hotspots of monocyte residence time were detected, suggesting that the monocyte infiltration responsible for the breakdown of the abdominal aortic aneurysm wall occurs heterogeneously. Peak monocyte residence time was found to increase with aneurysm sac size. Further work addressing certain limitations is needed in a larger cohort to determine clinical significance.
Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.
Lu, Pong-Jeu; Yang, Chi-Fu Jeffrey; Wu, Meng-Yu; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng
2011-11-01
In counterpulsation, diastolic augmentation increases coronary blood flow and systolic unloading reduces left ventricular afterload. We present a new approach with wave intensity analysis to revisit and explain counterpulsation principles. In an acute porcine model, a standard intra-aortic balloon pump was placed in descending aorta in 4 pigs. We measured pressure and velocity with probes in left anterior descending artery and aorta during and without intra-aortic balloon pump assistance. Wave intensities of aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction. We identified predominating waves in counterpulsation. In the aorta, during diastolic augmentation, intra-aortic balloon inflation generated a backward compression wave, with a "pushing" effect toward the aortic root that translated to a forward compression wave into coronary circulation. During systolic unloading, intra-aortic balloon pump deflation generated a backward expansion wave that "sucked" blood from left coronary bed into the aorta. While this backward expansion wave translated to reduced left ventricular afterload, the "sucking" effect resulted in left coronary blood steal, as demonstrated by a forward expansion wave in left anterior descending coronary flow. The waves were sensitive to inflation and deflation timing, with just 25 ms delay from standard deflation timing leading to weaker forward expansion wave and less coronary regurgitation. Intra-aortic balloon pumps generate backward-traveling waves that predominantly drive aortic and coronary blood flow during counterpulsation. Wave intensity analysis of arterial circulations may provide a mechanism to explain diastolic augmentation and systolic unloading of intra-aortic balloon pump counterpulsation. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Kon, Neal D; Riley, Robert D; Adair, Sandy M; Kitzman, Dalane W; Cordell, A Robert
2002-06-01
Stentless porcine aortic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation, and perhaps improved durability. One hundred four patients were operated on from September 17, 1992, to October 31, 1997, as part of a multicenter worldwide investigation of the Medtronic Freestyle stentless porcine bioprosthesis. All patients received a total aortic root replacement. The patients were evaluated postoperatively at discharge, at 3 to 6 months, and yearly by clinical examination and color flow Doppler echocardiography. Operative mortality was 3.9%. No patient experienced structural valve deterioration, nonstructural deterioration, perivalvular leak, or unacceptable hemodynamic performance. At 8 years, survival was 59.8%. Freedom from thromboembolic complications was 83.3%. Freedom from postoperative endocarditis was 96.9%. Freedom from reoperation was 100%. Mean systolic gradients did not change over the time period studied. They were 6.4 +/- 3.8 mm Hg at 1 year and 6.7 +/- 2.6 mm Hg at 8 years. Correspondingly, effective orifice area was 1.9 +/- 0.7 cm2 at 1 year and 1.8 +/- 0.8 cm2 at 8 years. The incidence of any aortic insufficiency also did not change over the length of follow-up. At 1 year, 98% of patients had no or trivial aortic insufficiency and 2% had mild aortic insufficiency. At 8 years, 100% of patients evaluated were free of any aortic insufficiency. The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root or aortic valve for aortic valve and aortic root pathology. Total root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Results up to 8 years show excellent survival and no signs of degeneration. Further follow-up is still needed to determine valve durability.
An augmented magnetic navigation system for Transcatheter Aortic Valve Implantation.
Luo, Zhe; Cai, Junfeng; Nie, Yuanyuan; Wang, Guotai; Gu, Lixu
2013-01-01
This research proposes an augmented magnetic navigation system for Transcatheter Aortic Valve Implantation (TAVI) employing a magnetic tracking system (MTS) combined with a dynamic aortic model and intra-operative ultrasound (US) images. The dynamic 3D aortic model is constructed based on the preoperative 4D computed tomography (CT), which is animated according to the real time electrocardiograph (ECG) input of patient. And a preoperative planning is performed to determine the target position of the aortic valve prosthesis. The temporal alignment is performed to synchronize the ECG signals, intra-operative US image and tracking information. Afterwards, with the assistance of synchronized ECG signals, the contour of aortic root automatic extracted from short axis US image is registered to the dynamic aortic model by a feature based registration intra-operatively. Then the augmented MTS guides the interventionist to confidently position and deploy the aortic valve prosthesis to target. The system was validated by animal studies on three porcine subjects, the deployment and tilting errors of which are 3.17 ± 0.91 mm and 7.40 ± 2.89° respectively.
Spontaneous rupture of the ascending aorta.
Bin Mahmood, Syed Usman; Ulrich, Andrew; Safdar, Basmah; Geirsson, Arnar; Mangi, Abeel A
2018-02-01
Nontraumatic, spontaneous rupture of the ascending aorta is rare and the etiology is largely unknown. We reviewed seven patients from our institution, with no known aortic disease or hereditary connective tissue disorder that presented with spontaneous ascending aortic rupture from 2012 to 2017. Most patients presented with non-radiating chest pain along with hypertension (71.4%). The mean ascending aortic diameter at rupture was 4.60 ± 0.62 cm. The median door-to-operating room time was 2.58 h, resulting from effective implementation of an aortic emergency protocol. There were no operative mortalities. In patients with ascending aortic rupture, aortic diameter may not always correlate with the risk of rupture. Rapid diagnosis combined with a multidisciplinary approach is vital for the successful management of these high-risk patients. © 2018 Wiley Periodicals, Inc.
Outcomes of Aortic Valve-Sparing Operations in Marfan Syndrome.
David, Tirone E; David, Carolyn M; Manlhiot, Cedric; Colman, Jack; Crean, Andrew M; Bradley, Timothy
2015-09-29
In many cardiac units, aortic valve-sparing operations have become the preferred surgical procedure to treat aortic root aneurysm in patients with Marfan syndrome, based on relatively short-term outcomes. This study examined the long-term outcomes of aortic valve-sparing operations in patients with Marfan syndrome. All patients with Marfan syndrome operated on for aortic root aneurysm from 1988 through 2012 were followed prospectively for a median of 10 years. Follow-up was 100% complete. Time-to-event analyses were calculated using the Kaplan-Meier method with log-rank test for comparisons. A total of 146 patients with Marfan syndrome had aortic valve-sparing operations. Reimplantation of the aortic valve was performed in 121 and remodeling of the aortic root was performed in 25 patients. Mean age was 35.7 ± 11.4 years and two-thirds were men. Nine patients had acute, 2 had chronic type A, and 3 had chronic type B aortic dissections before surgery. There were 1 operative and 6 late deaths, 5 caused by complications of dissections. Mortality rate at 15 years was 6.8 ± 2.9%, higher than the general population matched for age and sex. Five patients required reoperation on the aortic valve: 2 for endocarditis and 3 for aortic insufficiency. Three patients developed severe, 4 moderate, and 3 mild-to-moderate aortic insufficiency. Rate of aortic insufficiency at 15 years was 7.9 ± 3.3%, lower after reimplantation than remodeling. Nine patients developed new distal aortic dissections during follow-up. Rate of dissection at 15 years was 16.5 ± 3.4%. Aortic valve-sparing operations in patients with Marfan syndrome were associated with low rates of valve-related complications in long-term follow-up. Residual and new aortic dissections were the leading cause of death. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Fibrin Sealant Improves Hemostasis in Peripheral Vascular Surgery: A Randomized Prospective Trial
Schenk, Worthington G.; Burks, Sandra G.; Gagne, Paul J.; Kagan, Steven A.; Lawson, Jeffrey H.; Spotnitz, William D.
2003-01-01
Objective To evaluate the efficacy and safety of an investigational fibrin sealant (FS) in a randomized prospective, partially blinded, controlled, multicenter trial. Summary Background Data Upper extremity vascular access surgery using polytetrafluorethylene (PTFE) graft placement for dialysis was chosen as a reproducible, clinically relevant model for evaluating the usefulness of FS. The FS consisted of pooled human fibrinogen (60 mg/mL) and thrombin (500 NIH U/mL). Time to hemostasis was measured, and adverse events were monitored. Methods Consenting adult patients (n = 48) undergoing placement of a standard PTFE graft were randomized in a 2:1:1 ratio to the treatment group using FS (ZLB Bioplasma AG, Bern, Switzerland), oxidized regenerated cellulose (Surgicel, Johnson & Johnson, New Brunswick, NJ), or pressure. Patients received heparin (3,000 IU IVP) before placement of vascular clamps. If the treatment was FS, clamps were left in place for 120 seconds after the application of study material to permit polymerization. If treatment was Surgicel, clamps were left in place until the agent had been applied according to manufacturer’s instructions. If the treatment was pressure, clamps were released as soon as the investigator was ready to apply compression. Immediately after release of the last clamp, the arterial and venous suture lines were evaluated for bleeding. The time to hemostasis at both the venous and arterial sites was recorded. Results Significant (P ≤ .005) reduction in time to hemostasis was achieved in the FS group. Thirteen (54.2%) patients randomized to FS experienced immediate hemostasis at both suture lines following clamp removal compared to no patients using Surgicel or pressure. Only one patient (7.1%) in the Surgicel group and no patients in the pressure group experienced hemostasis at 120 seconds from clamp removal, compared to 13 (54.2%) patients for FS. Adverse events were comparable in all groups. There were no seroconversions. Conclusions FS achieved more rapid hemostasis than traditional techniques in this peripheral vascular procedure. FS use appeared to be safe for this procedure. PMID:12796584
Besch, Stephen R; Suchyna, Thomas; Sachs, Frederick
2002-10-01
We built a high-speed, pneumatic pressure clamp to stimulate patch-clamped membranes mechanically. The key control element is a newly designed differential valve that uses a single, nickel-plated piezoelectric bending element to control both pressure and vacuum. To minimize response time, the valve body was designed with minimum dead volume. The result is improved response time and stability with a threefold decrease in actuation latency. Tight valve clearances minimize the steady-state air flow, permitting us to use small resonant-piston pumps to supply pressure and vacuum. To protect the valve from water contamination in the event of a broken pipette, an optical sensor detects water entering the valve and increases pressure rapidly to clear the system. The open-loop time constant for pressure is 2.5 ms for a 100-mmHg step, and the closed-loop settling time is 500-600 micros. Valve actuation latency is 120 micros. The system performance is illustrated for mechanically induced changes in patch capacitance.
O'Byrne, Michael L; Gillespie, Matthew J; Kennedy, Kevin F; Dori, Yoav; Rome, Jonathan J; Glatz, Andrew C
2017-01-01
Concern regarding aortic erosion has focused attention on the retro-aortic rim in patients undergoing device closure of atrial septal defects (ASD), but its effect on early outcomes is not well studied. A multicenter retrospective cohort study of patients undergoing device occlusion of ASD between 1/2011-10/2014 was performed, using data from the IMproving Pediatric and Adult Congenital Treatment Registry. Subjects were divided between those with retro-aortic rim <5 and ≥5 mm. Primary outcomes were technical failure and major early adverse events. Case times were measured as surrogates of technical complexity. The effect of deficient retro-aortic rim on primary outcomes was assessed using hierarchical logistic regression, adjusting for other suspected covariates and assessing whether they represent independent risk factors RESULTS: 1,564 subjects (from 77 centers) were included, with deficient retro-aortic rim present in 40%. Technical failure occurred in 91 subjects (5.8%) and a major early adverse event in 64 subjects (4.1%). Adjusting for known covariates, the presence of a deficient retro-aortic rim was not significantly associated with technical failure (OR: 1.3, 95% CI: 0.9-2.1) or major early adverse event (OR: 0.7, 95% CI: 0.4-1. 2). Total case (P = 0.01) and fluoroscopy time (P = 0.02) were greater in subjects with deficient rim, but sheath time was not significantly different (P = 0.07). Additional covariates independently associated with these outcomes were identified. Deficient retro-aortic rim was highly prevalent but not associated with increased risk of technical failure or early adverse events. Studies with longer follow-up are necessary to assess other outcomes, including device erosion. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Myocardial protection during minimally invasive cardiac surgery through right mini-thoracotomy.
De Palo, Micaela; Guida, Pietro; Mastro, Florinda; Nanna, Daniela; Quagliara, Teresa A P; Rociola, Ruggiero; Lionetti, Giosuè; Paparella, Domenico
2017-04-01
Myocardial damage is an independent predictor of adverse outcome following cardiac surgery and myocardial protection is one of the key factors to achieve successful outcomes. Cardioplegia with Custodiol is currently the most used cardioplegia during minimally invasive cardiac surgery (MICS). Different randomized controlled trials compared blood and Custodiol cardioplegia in the context of traditional cardiac surgery. No data are available for MICS. The aim of this study was to compare the efficacy of cold blood versus Custodiol cardioplegia during MICS. We retrospectively evaluated 90 patients undergoing MICS through a right mini-thoracotomy in a three-year period. Myocardial protection was performed using cold blood (44 patients, CBC group) or Custodiol (46 patients, Custodiol group) cardioplegia, based on surgeon preference and complexity of surgery. The primary outcomes were post-operative cardiac troponin I (cTnI) and creatine kinase MB (CKMB) serum release and the incidence of Low Cardiac Output Syndrome (LCOS). Aortic cross-clamp and cardiopulmonary bypass times were higher in the Custodiol group. No difference was observed in myocardial injury enzyme release (peak cTnI value was 18±46 ng/ml in CBC and 21±37 ng/ml in Custodiol; p=0.245). No differences were observed for mortality, LCOS, atrial or ventricular arrhythmias onset, transfusions, mechanical ventilation time duration, intensive care unit and total hospital stay. Custodiol and cold blood cardioplegic solutions seem to assure similar myocardial protection in patients undergoing cardiac surgery through a right mini-thoracotomy approach.
Single-center experience using the Freedom SOLO aortic bioprosthesis.
Iliopoulos, Dimitrios C; Deveja, Aris Rezar; Androutsopoulou, Vasiliki; Filias, Vasilios; Kastelanos, Eleftherios; Satratzemis, Vasilios; Khalpey, Zain; Koudoumas, Dimitrios
2013-07-01
This study reviews a single institution experience with the Freedom SOLO (Sorin Group, Saluggia, Italy) aortic bioprosthesis. Between October 2006 and February 2010, 128 patients (64 men, 64 women; mean age, 75.8 ± 5.1 years) underwent aortic valve replacement using the Freedom SOLO stentless aortic valve. The follow-up time was 36.7 ± 1.2 months and 100% complete. Concomitant procedures were performed in 77 patients (60%). The mean standard European System for Cardiac Operative Risk Evaluation was 9 ± 2.7. Grade 3 aortic stenosis was present in 73% of patients, mixed aortic stenosis and regurgitation were present in 40% of patients, and mitral regurgitation was present in 46% of patients. The mean crossclamp time was 53 ± 12 minutes for isolated Freedom SOLO aortic valve implantation and 80 ± 28 minutes for concomitant procedures, and the mean cardiopulmonary bypass time was 103 ± 31 minutes. The mean implanted valve size was 22.6 ± 1.4 mm. The mean intensive care unit and hospital stays were 2.4 ± 1.1 days and 8.8 ± 2.6 days, respectively. Three patients underwent reoperation for bleeding. The 15-day, 30-day, and perioperative mortality were all 4.6%. The 36-month survival was 95.4% ± 1.6% for the cohort with a low European System for Cardiac Operative Risk Evaluation (<9) and 88.6% ± 1.7% for the cohort with a high European System for Cardiac Operative Risk Evaluation (>9). Echocardiographic data preoperatively, immediately postoperatively, and at 3, 6, and 12 months postoperatively showed peak transvalvular gradients of 75 ± 23, 17 ± 6, 18 ± 6.5, 16 ± 6, and 16 ± 9 mm Hg, respectively (P < .001), and a mean left ventricular end-diastolic diameter of 51 ± 7, 50 ± 6, 48 ± 8, 47 ± 6, and 46.5 ± 7.5 mm, respectively (P < .05). There were only 3 cases of early mild aortic regurgitation (grade 1), which remained stable at 12 months. The Freedom SOLO stentless aortic valve has excellent early and intermediate-term results. Published by Mosby, Inc.
Clamp-crushing vs. radiofrequency-assisted liver resection:changes in liver function tests.
Palibrk, Ivan; Milicic, Biljana; Stojiljkovic, Ljuba; Manojlovic, Nebojsa; Dugalic, Vladimir; Bumbasirevic, Vesna; Kalezic, Nevena; Zuvela, Marinko; Milicevic, Miroslav
2012-05-01
Liver resection is the gold standard in managing patients with metastatic or primary liver cancer. The aim of our study was to compare the traditional clamp-crushing technique to the radiofrequency- assisted liver resection technique in terms of postoperative liver function. Liver function was evaluated preoperatively and on postoperative days 3 and 7. Liver synthetic function parameters (serum albumin level, prothrombin time and international normalized ratio), markers of hepatic injury and necrosis (serum alanine aminotransferase, aspartate aminotransferase and total bilirubin level) and microsomal activity (quantitative lidocaine test) were compared. Forty three patients completed the study (14 had clamp-crushing and 29 had radiofrequency assisted liver resection). The groups did not differ in demographic characteristics, pre-operative liver function, operative time and perioperative transfusion rate. In postoperative period, there were similar changes in monitored parameters in both groups except albumin levels, that were higher in radiofrequency-assisted liver resection group (p=0.047). Both, traditional clamp-crushing technique and radiofrequency assisted liver resection technique, result in similar postoperative changes of most monitored liver function parameters.
Incidence and crash mechanisms of aortic injury during the past decade.
Schulman, Carl I; Carvajal, Daniel; Lopez, Peter P; Soffer, Dror; Habib, Fahim; Augenstein, Jeffrey
2007-03-01
Aortic injuries were traditionally thought to be the result of severe frontal crashes. Newer data has suggested other crash types such as nearside crashes may also be important in aortic injury. We hypothesized the implementation of recent safety measures would decrease the incidence of aortic injury associated with fatal motor vehicle crashes. The autopsy reports of all traffic fatalities for motor vehicle occupants in a large urban county for the years 1993 to 2004 were examined. The demographics, impact types, safety measures used, and the presence of any aortic injury were recorded. Trends were evaluated for significance by weighted linear regression. The incidence of aortic injury associated with fatal motor vehicle crashes has remained unchanged during the past 12 years (r = 0.057, p = 0.45). There is a trend toward decreased aortic injuries associated with frontal crashes (r = 0.26, p = 0.089) but no change in aortic injuries associated with nearside or farside crashes (r = 0.053, p = 0.47), when the crash resulted in a fatality. This is despite an increase in seat belt use and increased presence of airbags during the same time period. Despite improved safety measures designed to minimize the occurrence of aortic injuries, the incidence of blunt aortic injury in fatal motor vehicle crashes has not decreased during the past decade. Although not statistically significant, there is a trend toward decreased frontal impacts in fatal motor vehicle crashes associated with aortic injuries. The nearside crash mechanism continues to play a prominent role, and efforts at improving vehicle safety should be focused on crash mechanisms as they relate to aortic injury.
Harrison, Oliver J; Moorjani, Narain; Torrens, Christopher; Ohri, Sunil K; Cagampang, Felino R
2016-01-01
Bicuspid aortic valve (BAV) disease is the most common congenital cardiac abnormality and predisposes patients to life-threatening aortic complications including aortic aneurysm. Quantitative real-time reverse transcription PCR (qRT-PCR) is one of the most commonly used methods to investigate underlying molecular mechanisms involved in aortopathy. The accuracy of the gene expression data is dependent on normalization by appropriate housekeeping (HK) genes, whose expression should remain constant regardless of aortic valve morphology, aortic diameter and other factors associated with aortopathy. Here, we identified an appropriate set of HK genes to be used as endogenous reference for quantifying gene expression in ascending aortic tissue using a spin column-based RNA extraction method. Ascending aortic biopsies were collected intra-operatively from patients undergoing aortic valve and/or ascending aortic surgery. These patients had BAV or tricuspid aortic valve (TAV), and the aortas were either dilated (≥4.5cm) or undilated. The cohort had an even distribution of gender, valve disease and hypertension. The expression stability of 12 reference genes were investigated (ATP5B, ACTB, B2M, CYC1, EIF4A2, GAPDH, SDHA, RPL13A, TOP1, UBC, YWHAZ, and 18S) using geNorm software. The most stable HK genes were found to be GAPDH, UBC and ACTB. Both GAPDH and UBC demonstrated relative stability regardless of valve morphology, aortic diameter, gender and age. The expression of B2M and SDHA were found to be the least stable HK genes. We propose the use of GAPDH, UBC and ACTB as reference genes for gene expression studies of BAV aortopathy using ascending aortic tissue.
Single center experience of aortic bypass graft for aortic arch obstruction in children.
Shinkawa, Takeshi; Chipman, Carl; Holloway, Jessica; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki
2017-01-01
The purpose of this study is to access the outcomes of aortic bypass graft placement in children. This is a retrospective review of all children having aortic bypass graft placement for aortic arch obstruction for the first time between 1982 and 2013 at a single institution. The actuarial survival and the freedom from aortic arch reoperation were calculated and compared between the groups. Seventy consecutive children underwent aortic bypass graft placements. The median age and body weight at the operation were 14 days and 3.6 kg. There were 7 early deaths, 6 late deaths, and 7 heart transplants during the median follow-up of 10.8 years (0.0-31.5 years). The actuarial transplant free survival was 64.7 % at 20 years and the freedom from aortic arch reoperation was 50.5 % at 10 years. Between the children younger than 1 year old and older than 1 year old, there were significant differences in actuarial transplant free survival (56.4 vs. 100 % at 15 years, p = 0.0042) and in the freedom from aortic arch reoperation (18.7 vs. 100 % at 10 years, p < 0.001). The children who received aortic bypass graft larger than 16 mm in size had no aortic arch reoperation at 15 years. The aortic bypass graft placement for aortic arch obstruction can be done with low mortality and morbidity for children who can receive bypass graft larger than 16 mm in size. However, it should be avoided for the neonates and infants except selected situations.
den Hartog, Alexander W.; Radonic, Teodora; de Vries, Carlie J. M.; Zwinderman, Aeilko H.; Groenink, Maarten; Mulder, Barbara J. M.; de Waard, Vivian
2014-01-01
Aims Patients with Marfan syndrome have an increased risk of life-threatening aortic complications, mostly preceded by aortic dilatation. In the FBN1 C1039G/+ Marfan mouse model, losartan decreases aortic root dilatation. We recently confirmed this beneficial effect of losartan in adult patients with Marfan syndrome. The straightforward translation of this mouse model to man is reassuring to test novel treatment strategies. A number of studies have shown signs of inflammation in aortic tissue of Marfan patients. This study examined the efficacy of anti-inflammatory therapies in attenuating aortic root dilation in Marfan syndrome and compared effects to the main preventative agent, losartan. Methods and Results To inhibit inflammation in FBN1 C1039G/+ Marfan mice, we treated the mice with losartan (angiotensin II receptor type 1 inhibitor), methylprednisolone (corticosteroid) or abatacept (T-cell-specific inhibitor). Treatment was initiated in adult Marfan mice with already existing aortic root dilatation, and applied for eight weeks. Methylprednisolone- or abatacept-treated mice did not reveal a reduction in aortic root dilatation. In this short time frame, losartan was the only treatment that significantly reduced aorta inflammation, transforming growth factor-beta (TGF-β) signaling and aortic root dilatation rate in these adult Marfan mice. Moreover, the methylprednisolone-treated mice had significantly more aortic alcian blue staining as a marker for aortic damage. Conclusion Anti-inflammatory agents do not reduce the aortic dilatation rate in Marfan mice, but possibly increase aortic damage. Currently, the most promising therapeutic drug in Marfan syndrome is losartan, by blocking the angiotensin II receptor type 1 and thereby inhibiting pSmad2 signaling. PMID:25238161
Time course of pressure and flow in ascending aorta during ejection.
Perlini, S; Soldà, P L; Piepoli, M; Calciati, A; Paro, M; Marchetti, G; Meno, F; Finardi, G; Bernardi, L
1991-02-01
To analyze aortic flow and pressure relationships, 10 closed-chest anaesthetised dogs were instrumented with electromagnetic aortic flow probes and micromanometers in the left ventricle and ascending aorta. Left ventricular ejection time was divided into: time to peak flow (T1) (both pressure and flow rising), peak flow to peak pressure time (T2) (pressure rising, flow decreasing), and peak pressure to dicrotic notch time (T3) (pressure and flow both decreasing). These time intervals were expressed as percent of total ejection time. Load-active interventions rose markedly T2 (from 4.2 +/- 5.5 to 19.4 +/- 3.5 after phenylephrine (p less than 0.02); from 4.2 +/- 6.5 to 21.2 +/- 5.3 after dextran (p less than 0.02)). Conversely, dobutamine reduced T2 from 4.4 +/- 5.9 to -2.5 +/- 6.5 (p less than 0.05). Thus, during load-active interventions aortic pressure increases for a longer T2 time although forward flow is decreasing, as a result of higher aortic elastic recoil during ejection. Conversely, beta 1-adrenergic stimulation significantly shortens T2. Dynamic pressure-flow relationship is thus continuously changing during ejection. T2 seems to be inversely related to the efficiency of left ventricular ejection dynamics.
Bein, B; Turowski, P; Renner, J; Hanss, R; Steinfath, M; Scholz, J; Tonner, P H
2005-10-01
Xenon, a noble gas with anaesthetic and analgesic properties, has gained renewed interest due to its favourable physical properties which allow a rapid emergence from anaesthesia. However, high costs limit its use to a subset of patients who may benefit from xenon, thereby offsetting its costs. To date, there are only limited data available on the performance of xenon in high risk patients. We studied 39 patients with ASA physical status III undergoing aortic surgery. The patients were randomly assigned to either a xenon (Xe, n = 20) or a TIVA (T, n = 19) group. Global cardiac performance and myocardial contractility were assessed using transoesophageal echocardiography, and myocardial cell damage with troponin T and CK-MB. Echocardiographic measurements were made prior to xenon administration, following xenon administration, and after clamping of the abdominal aorta, after declamping and at corresponding time points in the TIVA group. Laboratory values were determined repeatedly for up to 72 h. Data were analysed using two-way anova factoring for time and anaesthetic agent or with ancova comparing linear regression lines. No significant differences were found in global myocardial performance, myocardial contractility or laboratory values at any time during the study period. Mean (SEM) duration of stay on the ICU (xenon: 38 +/- 46 vs. TIVA 25 +/- 15 h) or in hospital (xenon: 14 +/- 12 vs. TIVA 10 +/- 6 days) did not differ significantly between the groups. Although xenon has previously been shown to exert superior haemodynamic stability, we were unable to demonstrate an advantage of xenon-based anaesthesia compared to TIVA in high risk surgical patients.
Spectral infrared hemispherical reflectance measurements for LDEF tray clamps
NASA Technical Reports Server (NTRS)
Wood, Bobby E.; Cromwell, Brian K.; Pender, Charles W.; Shepherd, Seth D.
1992-01-01
This paper describes infrared hemispherical reflectance measurements (2-15 microns) that were made on 58 chromic acid anodized tray clamps retrieved from the LDEF spacecraft. These clamps were used for maintaining the experiments in place and were located at various locations about the spacecraft. Changes in reflectance of the tray clamps at these locations were compared with atomic oxygen fluxes at the same locations. A decrease in absorption band depth was seen for the surfaces exposed to space indicating that there was some surface layer erosion. In all of the surfaces measured, little evidence of contamination was observed and none of the samples showed evidence of the brown nicotine stain that was so prominent in other experiments. Total emissivity values were calculated for both exposed and unexposed tray clamp surfaces. Only small differences, usually less than 1 percent, were observed. The spectral reflectances were measured using a hemi-ellipsoidal mirror reflectometer matched with an interferometer spectrometer. The rapid scanning capability of the interferometer allowed the reflectance measurements to be made in a timely fashion. The ellipsoidal mirror has its two foci separated by 2 inches and located on the major axis. A blackbody source was located at one focus while the tray clamp samples were located at the conjugate focus. The blackbody radiation was modulated and then focused by the ellipsoid onto the tray clamps. Radiation reflected from the tray clamp was sampled by the interferometer by viewing through a hole in the ellipsoid. A gold mirror (reflectance approximately 98 percent) was used as the reference surface.
Rupture of an Abdominal Aortic Aneurysm in a Young Man with Marfan Syndrome.
Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren; Nielsen, Dorte Guldbrand; Andersen, Niels Holmark
2018-04-01
Abdominal aortic aneurysms (AAAs) are very rare in Marfan syndrome. We present a case with a young nonsmoking and normotensive male with Marfan syndrome, who developed an infrarenal AAA that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock. The patient had acute aortic surgery and survived. Five months before this incident, the patient had uneventful elective aortic root replacement (ad modum David) due to an enlarged aortic root. At that time, his abdominal aorta was assessed with a routine ultrasound scan that showed a normal-sized abdominal aorta. This documents that the aneurysm had evolved very rapidly despite young age and absence of risk factors. Copyright © 2018 Elsevier Inc. All rights reserved.
Smíd, Michal; Ferda, Jirí; Baxa, Jan; Cech, Jakub; Hájek, Tomás; Kreuzberg, Boris; Rokyta, Richard
2010-04-01
Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Enhancing 4D PC-MRI in an aortic phantom considering numerical simulations
NASA Astrophysics Data System (ADS)
Kratzke, Jonas; Schoch, Nicolai; Weis, Christian; Müller-Eschner, Matthias; Speidel, Stefanie; Farag, Mina; Beller, Carsten J.; Heuveline, Vincent
2015-03-01
To date, cardiovascular surgery enables the treatment of a wide range of aortic pathologies. One of the current challenges in this field is given by the detection of high-risk patients for adverse aortic events, who should be treated electively. Reliable diagnostic parameters, which indicate the urge of treatment, have to be determined. Functional imaging by means of 4D phase contrast-magnetic resonance imaging (PC-MRI) enables the time-resolved measurement of blood flow velocity in 3D. Applied to aortic phantoms, three dimensional blood flow properties and their relation to adverse dynamics can be investigated in vitro. Emerging "in silico" methods of numerical simulation can supplement these measurements in computing additional information on crucial parameters. We propose a framework that complements 4D PC-MRI imaging by means of numerical simulation based on the Finite Element Method (FEM). The framework is developed on the basis of a prototypic aortic phantom and validated by 4D PC-MRI measurements of the phantom. Based on physical principles of biomechanics, the derived simulation depicts aortic blood flow properties and characteristics. The framework might help identifying factors that induce aortic pathologies such as aortic dilatation or aortic dissection. Alarming thresholds of parameters such as wall shear stress distribution can be evaluated. The combined techniques of 4D PC-MRI and numerical simulation can be used as complementary tools for risk-stratification of aortic pathology.
Abdominal Infrarenal Aortic Stenosis Approached Through a Full Transradial Approach: A Case Series.
Porto, Italo; Burzotta, Francesco; Aurigemma, Cristina; Gustapane, Massimo; Trani, Carlo
2017-07-01
Six consecutive patients (3 men; mean age, 63 ± 14 years; age range, 38-81 years) with infrarenal abdominal aortic stenosis underwent unilateral or bilateral transradial approach for stenting of the aortic lesion. In 4 cases, isolated aortic stenting was performed through single transradial approach (in 2 cases with precise alignment to the proximal end of previously deployed iliac stents), whereas in the other 2 cases bilateral transradial approach was used for aortic stenting followed by bilateral stenting of the proximal iliac arteries. Either a "bare-on-the-wire" or a "support-catheter" technique was used, according to patient anatomy and technical requirements. The median follow-up was 14.3 months, at which time all patients had relief of symptoms without thromboembolic or bleeding complications. In this performance and safety evaluation, full transradial approach was effective and safe for treating infrarenal aortic stenosis that is isolated or associated with iliac disease.
Bicuspid aortic valve syndrome: a multidisciplinary approach for a complex entity
Lorca, Rebeca; Rozado, José; Alvarez-Cabo, Rubén; Calvo, Juan; Pascual, Isaac; Cigarrán, Helena; Rodríguez, Isabel; Morís, César
2017-01-01
Bicuspid aortic valve (BAV) or bicuspid aortopathy is the most common congenital heart disease. It can be clinically silent and it is often identified as an incidental finding in otherwise healthy, asymptomatic patients. However, it can be dysfunctioning at birth, even requiring neonatal intervention, or, in time, lead to aortic stenosis, aortic insufficiency, and endocarditis, and also be associated with aortic aneurysm and aortic dissection. Given its prevalence and significant complications, it is estimated that BAV is responsible for more deaths and morbidity than the combined effects of all the other congenital heart defects. Pathology of BAV is still not well known and many questions are unresolved. In this manuscript we review some aspects on bicuspid aortopathy, a heterogeneous and frequent disease in which like some authors have previously described, complex gene environment are present. Further investigations and, what is more, multidisciplinary teams are needed to improve our knowledge on this really fascinating disease. PMID:28616342
Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C
2018-05-01
Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the treatment of severe aortic stenosis in patients with intermediate surgical risk. There remains moderate-to-high uncertainty surrounding the base-case incremental cost-effectiveness ratio. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
FPGA in-the-loop simulations of cardiac excitation model under voltage clamp conditions
NASA Astrophysics Data System (ADS)
Othman, Norliza; Adon, Nur Atiqah; Mahmud, Farhanahani
2017-01-01
Voltage clamp technique allows the detection of single channel currents in biological membranes in identifying variety of electrophysiological problems in the cellular level. In this paper, a simulation study of the voltage clamp technique has been presented to analyse current-voltage (I-V) characteristics of ion currents based on Luo-Rudy Phase-I (LR-I) cardiac model by using a Field Programmable Gate Array (FPGA). Nowadays, cardiac models are becoming increasingly complex which can cause a vast amount of time to run the simulation. Thus, a real-time hardware implementation using FPGA could be one of the best solutions for high-performance real-time systems as it provides high configurability and performance, and able to executes in parallel mode operation. For shorter time development while retaining high confidence results, FPGA-based rapid prototyping through HDL Coder from MATLAB software has been used to construct the algorithm for the simulation system. Basically, the HDL Coder is capable to convert the designed MATLAB Simulink blocks into hardware description language (HDL) for the FPGA implementation. As a result, the voltage-clamp fixed-point design of LR-I model has been successfully conducted in MATLAB Simulink and the simulation of the I-V characteristics of the ionic currents has been verified on Xilinx FPGA Virtex-6 XC6VLX240T development board through an FPGA-in-the-loop (FIL) simulation.
Potanos, Kristina; Fullington, Nora; Cauley, Ryan; Purcell, Patricia; Zurakowski, David; Fishman, Steven; Vakili, Khashayar; Kim, Heung Bae
2016-04-01
We examine the mechanism of aortic lengthening in a novel rodent model of tissue expander stimulated lengthening of arteries (TESLA). A rat model of TESLA was examined with a single stretch stimulus applied at the time of tissue expander insertion with evaluation of the aorta at 2, 4 and 7day time points. Measurements as well as histology and proliferation assays were performed and compared to sham controls. The aortic length was increased at all time points without histologic signs of tissue injury. Nuclear density remained unchanged despite the increase in length suggesting cellular hyperplasia. Cellular proliferation was confirmed in endothelial cell layer by Ki-67 stain. Aortic lengthening may be achieved using TESLA. The increase in aortic length can be achieved without tissue injury and results at least partially from cellular hyperplasia. Further studies are required to define the mechanisms involved in the growth of arteries under increased longitudinal stress. Copyright © 2015 Elsevier Inc. All rights reserved.
Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj
2015-01-01
Background. Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. Materials and Methods. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. Results. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05). Conclusions. Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time. PMID:26583092
Piezoresistive cantilever force-clamp system
Park, Sung-Jin; Petzold, Bryan C.; Goodman, Miriam B.; Pruitt, Beth L.
2011-01-01
We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or “clamps” the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of μN force and nm up to tens of μm displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode. PMID:21529009
Kalotka-Bratek, H; Drobinski, G; Klimczak, K; Busquet, P; Fraysse, J B; Bejean-Lebuisson, A; Grosgogeat, Y
1989-02-01
In 20 patients with pure aortic regurgitation we studied the relationship between the severity of regurgitation, as assessed haemodynamically by the percentage of leakage (%L), and the half-pressure (T 1/2 P) and half-velocity (T 1/2 V) times, as obtained from doppler aortic blood velocity curves, taking into account the rigidity of the systemic vascular circuit characterized by the pressure wave propagation velocity (PWPV). The systemic arterial circuit was supple in 14 patients (PWPV less than 7.5 m/sec) and rigid in 6 patients (PWPV greater than 7.5 m/sec). The regression slopes between %L and T 1/2 P and between %L and T 1/2 V were calculated with their confidence limits in the 14 patients with supple arteries. The 6 patients with rigid arteries fitted into this nomogram, thus demonstrating that systemic arterial rigidity makes no difference in the relationship between %L and doppler indices. The half-velocity and half-pressure times measured by doppler ultrasound were acquired from a velocity signal directly determined by the aortic regurgitation, without any detectable effect of vascular circuit rigidity. Being equivalent by nature to the signal decrease time constant, they are independent of the absolute protodiastolic value of diastolic pressure gradient or blood flow velocity. For this reason these two doppler parameters are reliable to evaluate the severity of aortic regurgitation.
Goudeketting, Seline R; Heinen, Stefan G H; Ünlü, Çağdaş; van den Heuvel, Daniel A F; de Vries, Jean-Paul P M; van Strijen, Marco J; Sailer, Anna M
2017-08-01
To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time. Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time. The contrast use for standard and complex endovascular aortic repairs (fenestrated, branched, and chimney) were pooled using a random-effects model; outcomes are reported as the mean difference with 95% confidence intervals (CIs). Seven studies, 5 retrospective and 2 prospective, involving 921 patients were selected for analysis. The methodological quality of the studies was moderate (median 17, range 15-18). The use of fusion imaging led to an estimated mean reduction in iodinated contrast of 40.1 mL (95% CI 16.4 to 63.7, p=0.002) for standard procedures and a mean 70.7 mL (95% CI 44.8 to 96.6, p<0.001) for complex repairs. Secondary outcome measures were not pooled because of potential bias in nonrandomized data, but radiation doses, procedure times, and fluoroscopy times were lower, although not always significantly, in the fusion group in 6 of the 7 studies. Compared with the control group, 3D fusion imaging is associated with a significant reduction in the volume of contrast employed for standard and complex endovascular aortic procedures, which can be particularly important in patients with renal failure. Radiation doses, procedure times, and fluoroscopy times were reduced when 3D fusion was used.
Consumption coagulopathy in acute aortic dissection: principles of management.
Liu, Yuyong; Han, Lu; Li, Jiachen; Gong, Ming; Zhang, Hongjia; Guan, Xinliang
2017-06-12
The effect of acute aortic dissection itself on coagulopathy or surgery-related coagulopathy has never been specifically studied. The aim of the present study was to perioperatively describe consumption coagulopathy in patients with acute aortic dissection. Sixty-six patients with acute type A aortic dissection were enrolled in this study from January 2015 to September 2016. Thirty-six patients with thoracic aortic aneurysms were used as a control group during the same period. Consumption coagulopathy was evaluated using standard laboratory tests, enzyme-linked immunosorbent assay and thromboelastograghy at five perioperative time-points. A significant reduction in clotting factors and fibrinogen was observed at the onset of acute aortic dissection. Enzyme-linked immunosorbent assay and thromboelastograghy also revealed a persistent systemic activation of the coagulation system and the consumption of clotting factors. In contrast, although platelet counts were consistently low, we did not find that platelet function was more impaired in the acute aortic dissection group than the control group. After surgery, clotting factors and fibrinogen were more impaired than platelet function. Thus, we proposed that hemostatic therapy should focus on the rapid and sufficient supplementation of clotting factors and fibrinogen to improve consumption coagulopathy in patients with acute aortic dissection.
Rapid prototyping of compliant human aortic roots for assessment of valved stents.
Kalejs, Martins; von Segesser, Ludwig Karl
2009-02-01
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.
Is early cord clamping, delayed cord clamping or cord milking best?
Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan
2018-04-01
To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p < .05) lower in the early cord clamping group compared with the other two groups. The disulfide/total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.
Vocal cord paralysis after aortic surgery.
DiLisio, Ralph P; Mazzeffi, Michael A; Bodian, Carol A; Fischer, Gregory W
2013-06-01
The purpose of this study was to investigate variables associated with vocal cord paralysis during complex aortic procedures. A retrospective review. A tertiary care center. Four hundred ninety-eight patients who underwent aortic surgery between 2002 and 2007. Two groups were studied. Group A patients had procedures only involving their aortic root and/or ascending aorta. Group B patients had procedures only involving their aortic arch and/or descending aorta. The incidence of vocal cord paralysis was higher (7.26% v 0.8%) in group B patients (p < 0.0001). Increasing the duration of cardiopulmonary bypass time was associated with an increased risk of vocal cord paralysis and death in both groups A and B (p = 0.0002 and 0.002, respectively). Additionally, within group B, descending aneurysms emerged as an independent risk factor associated with vocal cord paralysis (p = 0.03). Length of stay was statistically significantly longer among group A patients who suffered vocal cord paralysis (p = 0.017) and trended toward significance in group B patients who suffered vocal cord paralysis (p = 0.059). The association between tracheostomy and vocal cord paralysis among group A patients reached statistical significance (p = 0.007) and trended toward significance in group B patients (p = 0.057). Increasing duration of cardiopulmonary bypass time was associated with a higher risk of vocal cord paralysis in patients undergoing aortic surgery. Additionally, within group B patients, descending aortic aneurysm was an independent risk factor associated with vocal cord paralysis. Most importantly, vocal cord paralysis appeared to have an association between an increased length of stay and tracheostomy among a select group of patients undergoing aortic surgery. Copyright © 2013 Elsevier Inc. All rights reserved.
Ion channel drug discovery and research: the automated Nano-Patch-Clamp technology.
Brueggemann, A; George, M; Klau, M; Beckler, M; Steindl, J; Behrends, J C; Fertig, N
2004-01-01
Unlike the genomics revolution, which was largely enabled by a single technological advance (high throughput sequencing), rapid advancement in proteomics will require a broader effort to increase the throughput of a number of key tools for functional analysis of different types of proteins. In the case of ion channels -a class of (membrane) proteins of great physiological importance and potential as drug targets- the lack of adequate assay technologies is felt particularly strongly. The available, indirect, high throughput screening methods for ion channels clearly generate insufficient information. The best technology to study ion channel function and screen for compound interaction is the patch clamp technique, but patch clamping suffers from low throughput, which is not acceptable for drug screening. A first step towards a solution is presented here. The nano patch clamp technology, which is based on a planar, microstructured glass chip, enables automatic whole cell patch clamp measurements. The Port-a-Patch is an automated electrophysiology workstation, which uses planar patch clamp chips. This approach enables high quality and high content ion channel and compound evaluation on a one-cell-at-a-time basis. The presented automation of the patch process and its scalability to an array format are the prerequisites for any higher throughput electrophysiology instruments.
Silent Aortic Dissection Presenting as Transient Locked-In Syndrome
Nadour, Wadih; Goldwasser, Brian; Biederman, Robert W.; Taffe, Kevin
2008-01-01
Acute aortic dissection is a medical emergency. Without prompt recognition and treatment, the mortality rate is high. An atypical presentation makes timely diagnosis difficult, especially if the patient is experiencing no characteristic pain. Many patients with aortic dissection are reported to have presented with various neurologic manifestations, but none with only a presentation of transient locked-in syndrome. Herein, we report a case of completely painless aortic dissection in a woman who presented with a transient episode of anarthria, quadriplegia, and preserved consciousness. On physical examination, she had a 40-point difference in blood pressure between her left and right arms, and a loud diastolic murmur. The diagnosis of acute aortic dissection was reached via a combination of radiography, computed tomography, echocardiography, and a high index of clinical suspicion. The patient underwent emergency surgery and ultimately experienced a successful outcome. To our knowledge, this is the 1st report of aortic dissection that presented solely as locked-in syndrome. We suggest that silent aortic dissection be added to the differential diagnosis for transient locked-in syndrome. PMID:18941610
Bulur, Serkan; Hsiung, Ming C; Nanda, Navin C; Hardas, Shalaka; Mohamed, Ahmed; ElKaryoni, Ahmed; Srialluri, Swetha; Barssoum, Kirolos; Elsayed, Mahmoud; Wei, Jeng; Yin, Wei-Hsian
2016-11-01
We present a case of an adult with metastatic carcinoid heart disease, in whom live/real time three-dimensional transthoracic echocardiography provided incremental value over two-dimensional transthoracic echocardiography in assessing involvement of the aortic valve. © 2016, Wiley Periodicals, Inc.
Robotic partial nephrectomy with selective parenchymal compression (Simon clamp).
Castillo, O A; Rodriguez-Carlin, A; Lopez-Fontana, G; Aleman, E
2013-01-01
To present our initial experience using selective renal parenchymal ischemia, without hilar clamping, in robotic-assisted partial nephrectomy. In four patients with T1a renal tumor we performed robotic-assisted partial nephrectomy, using the Simon's clamp (Aesculap). It provides selective parenchymal compression without the need of vascular clamping. All patients had exofitic renal tumors in polar location. Renal parenchymal reconstruction was done as the standard technique. The median age was 49.6 years (42-59), 3 male and 1 female patient. Median operative time was 71,6 minutes (40-120). Mean stimated bleeding was 250 ml (50-400). Average tumor size was 3,25 cm (1,5-5,3). There were no complications and the average hospital stay was 3,5 days (1-7). The pathology was informed as renal cell carcinoma in three patients and one hemorrhagic cyst. The surgical margins were negative. Our preliminary results shows that selective renal parenchymal compression, with the Simon's clamp, provides an alternative to vascular control in selected patients with polar renal tumors. Copyright © 2012 AEU. Published by Elsevier Espana. All rights reserved.
Martinelli, F; Signorelli, M; Bogani, G; Ditto, A; Chiappa, V; Perotto, S; Scaffa, C; Lorusso, D; Raspagliesi, F
2016-10-01
The aim of this study was to estimate the rate of aortic lymph nodes (LN) metastases/recurrences among patients affected by locally advanced stage cancer patients (LACC), treated with neoadjuvant chemotherapy (NACT) and radical surgery. Retrospective evaluation of consecutive 261 patients affected by LACC (stage IB2-IIB), treated with NACT followed by radical surgery at National Cancer Institute, Milan, Italy, between 1990 and 2011. Stage at presentation included stage IB2, IIA and IIB in 100 (38.3%), 50 (19.2%) and 111 (42.5%) patients, respectively. Squamous cell carcinoma accounted for more than 80%, followed by adenocarcinoma or adenosquamous cancers (20%). Overall, 56 women (21.5%) had LN metastases. Four out of 83 women (5%) who underwent both pelvic and aortic LN dissection had aortic LN metastases, and all women had concomitant pelvic and aortic LN metastases. Only one woman out of 178 (0.5%) who underwent pelvic lymphadenectomy only, had an aortic LN recurrence. Overall 2% of women (5/261) had aortic LN metastases/recurrence. Our data suggest that aortic lymphadenectomy at the time of surgery is not routinely indicated in LACC after NACT, but should reserved in case of bulky LN in both pelvic and/or aortic area. The risk of isolated aortic LN relapse is negligible. Further prospective studies are warranted. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.
Cacho, J; Sevillano, J; de Castro, J; Herrera, E; Ramos, M P
2008-11-01
Insulin resistance plays a role in the pathogenesis of diabetes, including gestational diabetes. The glucose clamp is considered the gold standard for determining in vivo insulin sensitivity, both in human and in animal models. However, the clamp is laborious, time consuming and, in animals, requires anesthesia and collection of multiple blood samples. In human studies, a number of simple indexes, derived from fasting glucose and insulin levels, have been obtained and validated against the glucose clamp. However, these indexes have not been validated in rats and their accuracy in predicting altered insulin sensitivity remains to be established. In the present study, we have evaluated whether indirect estimates based on fasting glucose and insulin levels are valid predictors of insulin sensitivity in nonpregnant and 20-day-pregnant Wistar and Sprague-Dawley rats. We have analyzed the homeostasis model assessment of insulin resistance (HOMA-IR), the quantitative insulin sensitivity check index (QUICKI), and the fasting glucose-to-insulin ratio (FGIR) by comparing them with the insulin sensitivity (SI(Clamp)) values obtained during the hyperinsulinemic-isoglycemic clamp. We have performed a calibration analysis to evaluate the ability of these indexes to accurately predict insulin sensitivity as determined by the reference glucose clamp. Finally, to assess the reliability of these indexes for the identification of animals with impaired insulin sensitivity, performance of the indexes was analyzed by receiver operating characteristic (ROC) curves in Wistar and Sprague-Dawley rats. We found that HOMA-IR, QUICKI, and FGIR correlated significantly with SI(Clamp), exhibited good sensitivity and specificity, accurately predicted SI(Clamp), and yielded lower insulin sensitivity in pregnant than in nonpregnant rats. Together, our data demonstrate that these indexes provide an easy and accurate measure of insulin sensitivity during pregnancy in the rat.
Yi, Ruirong; Mukaiyama, Hiroyuki; Tachikawa, Takashi; Shimomura, Norihiro; Aimi, Tadanori
2010-01-01
In the bipolar basidiomycete Pholiota microspora, a pair of homeodomain protein genes located at the A-mating-type locus regulates mating compatibility. In the present study, we used a DNA-mediated transformation system in P. microspora to investigate the homeodomain proteins that control the clamp formation. When a single homeodomain protein gene (A3-hox1 or A3-hox2) from the A3 monokaryon strain was transformed into the A4 monokaryon strain, the transformants produced many pseudoclamps but very few clamps. When two homeodomain protein genes (A3-hox1 and A3-hox2) were transformed either separately or together into the A4 monokaryon, the ratio of clamps to the clamplike cells in the transformants was significantly increased to ca. 50%. We therefore concluded that the gene dosage of homeodomain protein genes is important for clamp formation. When the sip promoter was connected to the coding region of A3-hox1 and A3-hox2 and the fused fragments were introduced into NGW19-6 (A4), the transformants achieved more than 85% clamp formation and exhibited two nuclei per cell, similar to the dikaryon (NGW12-163 × NGW19-6). The results of real-time reverse transcription-PCR confirmed that sip promoter activity is greater than that of the native promoter of homeodomain protein genes in P. microspora. Thus, we concluded that nearly 100% clamp formation requires high expression levels of homeodomain protein genes and that altered expression of the A-mating-type genes alone is sufficient to drive true clamp formation. PMID:20453073
Niiranen, Laila; Lian, Kjersti; Johnson, Kenneth A; Moe, Elin
2015-02-27
Deinococcus radiodurans is an extremely radiation and desiccation resistant bacterium which can tolerate radiation doses up to 5,000 Grays without losing viability. We are studying the role of DNA repair and replication proteins for this unusual phenotype by a structural biology approach. The DNA polymerase III β subunit (β-clamp) acts as a sliding clamp on DNA, promoting the binding and processivity of many DNA-acting proteins, and here we report the crystal structure of D. radiodurans β-clamp (Drβ-clamp) at 2.0 Å resolution. The sequence verification process revealed that at the time of the study the gene encoding Drβ-clamp was wrongly annotated in the genome database, encoding a protein of 393 instead of 362 amino acids. The short protein was successfully expressed, purified and used for crystallisation purposes in complex with Cy5-labeled DNA. The structure, which was obtained from blue crystals, shows a typical ring-shaped bacterial β-clamp formed of two monomers, each with three domains of identical topology, but with no visible DNA in electron density. A visualisation of the electrostatic surface potential reveals a highly negatively charged outer surface while the inner surface and the dimer forming interface have a more even charge distribution. The structure of Drβ-clamp was determined to 2.0 Å resolution and shows an evenly distributed electrostatic surface charge on the DNA interacting side. We hypothesise that this charge distribution may facilitate efficient movement on encircled DNA and help ensure efficient DNA metabolism in D. radiodurans upon exposure to high doses of ionizing irradiation or desiccation.
Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.
Luechinger, Roger; Boesiger, Peter; Disegi, John A
2007-07-01
Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated. Copyright 2006 Wiley Periodicals, Inc.
Assmann, Alexander; Gül, Fethi; Benim, Ali Cemal; Joos, Franz; Akhyari, Payam; Lichtenberg, Artur
2015-03-01
Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with special regard to the resulting wall shear stress profiles. An idealized numerical model of the human aorta and its branches was created and used to model straight as well as bent dispersive aortic cannulas with meshlike tips inserted in the distal ascending aorta. Standard cannulas with straight beveled or bent tips served as controls. Using a recently optimized computing method, simulations of pulsatile and nonpulsatile extracorporeal circulation were performed. Dispersive aortic cannulas reduced the maximum and average aortic wall shear stress values to approximately 50% of those with control cannulas, while the difference in local values was even larger. Moreover, under pulsatile circulation, dispersive cannulas shortened the time period during which wall shear stress values were increased. The turbulent kinetic energy was also diminished by utilizing dispersive cannulas, reducing the risk of hemolysis. In summary, dispersive aortic cannulas decrease aortic wall shear stress and turbulence during extracorporeal circulation and may therefore reduce the risk of endothelial and blood cell damage as well as that of neurologic complications caused by atherosclerotic plaque mobilization. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
A model for predicting aortic dynamic response to -G sub z impact acceleration.
NASA Technical Reports Server (NTRS)
Advani, S. H.; Tarnay, T. J.; Byars, E. F.; Love, J. S.
1972-01-01
A steady state dynamic response model for the radial motion of the aorta is developed from in vivo pressure-displacement and nerve stimulation experiments on canines. The model represented by a modified Van der Pol wave motion oscillator closely predicts steady state and perturbed response results. The applicability of the steady state canine aortic model to tailward acting impact forces is studied by means of the perturbed phase plane of the oscillator. The backflow through the aortic arch resulting from a specified acceleration-time profile is computed and an analysis for predicting the forced motion aortic response is presented.
Vamvakidou, Anastasia; Jin, Wenying; Danylenko, Oleksandr; Chahal, Navtej; Khattar, Rajdeep; Senior, Roxy
2018-03-09
This study aimed to assess the value of low transvalvular flow rate (FR) for the prediction of mortality compared with low stroke volume index (SVi) in patients with low-gradient (mean gradient: <40 mm Hg), low aortic valve area (<1 cm 2 ) aortic stenosis (AS) following aortic valve intervention. Transaortic FR defined as stroke volume/left ventricular ejection time is also a marker of flow; however, no data exist comparing the relative prognostic value of these 2 transvalvular flow markers in patients with low-gradient AS who had undergone valve intervention. We retrospectively followed prospectively assessed consecutive patients with low-gradient, low aortic valve area AS who underwent aortic valve intervention between 2010 and 2014 for all-cause mortality. Of the 218 patients with mean age 75 ± 12 years, 102 (46.8%) had low stroke volume index (SVi) (<35 ml/m 2 ), 95 (43.6%) had low FR (<200 ml/s), and 58 (26.6%) had low left ventricular ejection fraction <50%. The concordance between FR and SVi was 78.8% (p < 0.005). Over a median follow-up of 46.8 ± 21 months, 52 (23.9%) deaths occurred. Patients with low FR had significantly worse outcome compared with those with normal FR (p < 0.005). In patients with low SVi, a low FR conferred a worse outcome than a normal FR (p = 0.005), but FR status did not discriminate outcome in patients with normal SVi. By contrast, SVi did not discriminate survival either in patients with normal or low FR. Low FR was an independent predictor of mortality (p = 0.013) after adjusting for age, clinical prognostic factors, European System for Cardiac Operative Risk Evaluation II, dimensionless velocity index, left ventricular mass index, left ventricular ejection fraction, heart rate, time, type of aortic valve intervention, and SVi (p = 0.59). In patients with low-gradient, low valve area aortic stenosis undergoing aortic valve intervention, low FR, not low SVi, was an independent predictor of medium-term mortality. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Kacprzak, Michal; Liebert, Adam; Staszkiewicz, Walerian; Gabrusiewicz, Andrzej; Sawosz, Piotr; Madycki, Grzegorz; Maniewski, Roman
2012-01-01
Recent studies have shown that time-resolved optical measurements of the head can estimate changes in the absorption coefficient with depth discrimination. Thus, changes in tissue oxygenation, which are specific to intracranial tissues, can be assessed using this advanced technique, and this method allows us to avoid the influence of changes to extracerebral tissue oxygenation on the measured signals. We report the results of time-resolved optical imaging that was carried out during carotid endarterectomy. This surgery remains the "gold standard" treatment for carotid stenosis, and intraoperative brain oxygenation monitoring may improve the safety of this procedure. A time-resolved optical imager was utilized within the operating theater. This instrument allows for the simultaneous acquisition of 32 distributions of the time-of-flight of photons at two wavelengths on both hemispheres. Analysis of the statistical moments of the measured distributions of the time-of-flight of photons was applied for estimating changes in the absorption coefficient as a function of depth. Time courses of changes in oxy- and deoxyhemoglobin of the extra- and intracerebral compartments during cross-clamping of the carotid arteries were obtained. A decrease in the oxyhemoglobin concentration and an increase in the deoxyhemoglobin concentrations were observed in a large area of the head. Large changes were observed in the hemisphere ipsilateral to the site of clamped carotid arteries. Smaller amplitude changes were noted at the contralateral site. We also found that changes in the hemoglobin signals, as estimated from intracerebral tissue, are very sensitive to clamping of the internal carotid artery, whereas its sensitivity to clamping of the external carotid artery is limited. We concluded that intraoperative multichannel measurements allow for imaging of brain tissue hemodynamics. However, when monitoring the brain during carotid surgery, a single-channel measurement may be sufficient.
Atenolol versus Losartan in Children and Young Adults with Marfan's Syndrome
Lacro, R.V.; Dietz, H.C.; Sleeper, L.A.; Yetman, A.T.; Bradley, T.J.; Colan, S.D.; Pearson, G.D.; Tierney, E.S. Selamet; Levine, J.C.; Atz, A.M.; Benson, D.W.; Braverman, A.C.; Chen, S.; De Backer, J.; Gelb, B.D.; Grossfeld, P.D.; Klein, G.L.; Lai, W.W.; Liou, A.; Loeys, B.L.; Markham, L.W.; Olson, A.K.; Paridon, S.M.; Pemberton, V.L.; Pierpont, M.E.; Pyeritz, R.E.; Radojewski, E.; Roman, M.J.; Sharkey, A.M.; Stylianou, M.P.; Wechsler, S. Burns; Young, L.T.; Mahony, L.
2015-01-01
BACKGROUND Aortic-root dissection is the leading cause of death in Marfan's syndrome. Studies suggest that with regard to slowing aortic-root enlargement, losartan may be more effective than beta-blockers, the current standard therapy in most centers. METHODS We conducted a randomized trial comparing losartan with atenolol in children and young adults with Marfan's syndrome. The primary outcome was the rate of aortic-root enlargement, expressed as the change in the maximum aortic-root-diameter z score indexed to body-surface area (hereafter, aortic-root z score) over a 3-year period. Secondary outcomes included the rate of change in the absolute diameter of the aortic root; the rate of change in aortic regurgitation; the time to aortic dissection, aortic-root surgery, or death; somatic growth; and the incidence of adverse events. RESULTS From January 2007 through February 2011, a total of 21 clinical centers enrolled 608 participants, 6 months to 25 years of age (mean [±SD] age, 11.5±6.5 years in the atenolol group and 11.0±6.2 years in the losartan group), who had an aortic-root z score greater than 3.0. The baseline-adjusted rate of change (±SE) in the aortic-root z score did not differ significantly between the atenolol group and the losartan group (−0.139±0.013 and −0.107±0.013 standard-deviation units per year, respectively; P = 0.08). Both slopes were significantly less than zero, indicating a decrease in the degree of aortic-root dilatation relative to body-surface area with either treatment. The 3-year rates of aortic-root surgery, aortic dissection, death, and a composite of these events did not differ significantly between the two treatment groups. CONCLUSIONS Among children and young adults with Marfan's syndrome who were randomly assigned to losartan or atenolol, we found no significant difference in the rate of aortic-root dilatation between the two treatment groups over a 3-year period. (Funded by the National Heart, Lung, and Blood Institute and others; ClinicalTrials.gov number, NCT00429364.) PMID:25405392
Atenolol versus losartan in children and young adults with Marfan's syndrome.
Lacro, Ronald V; Dietz, Harry C; Sleeper, Lynn A; Yetman, Anji T; Bradley, Timothy J; Colan, Steven D; Pearson, Gail D; Selamet Tierney, E Seda; Levine, Jami C; Atz, Andrew M; Benson, D Woodrow; Braverman, Alan C; Chen, Shan; De Backer, Julie; Gelb, Bruce D; Grossfeld, Paul D; Klein, Gloria L; Lai, Wyman W; Liou, Aimee; Loeys, Bart L; Markham, Larry W; Olson, Aaron K; Paridon, Stephen M; Pemberton, Victoria L; Pierpont, Mary Ella; Pyeritz, Reed E; Radojewski, Elizabeth; Roman, Mary J; Sharkey, Angela M; Stylianou, Mario P; Wechsler, Stephanie Burns; Young, Luciana T; Mahony, Lynn
2014-11-27
Aortic-root dissection is the leading cause of death in Marfan's syndrome. Studies suggest that with regard to slowing aortic-root enlargement, losartan may be more effective than beta-blockers, the current standard therapy in most centers. We conducted a randomized trial comparing losartan with atenolol in children and young adults with Marfan's syndrome. The primary outcome was the rate of aortic-root enlargement, expressed as the change in the maximum aortic-root-diameter z score indexed to body-surface area (hereafter, aortic-root z score) over a 3-year period. Secondary outcomes included the rate of change in the absolute diameter of the aortic root; the rate of change in aortic regurgitation; the time to aortic dissection, aortic-root surgery, or death; somatic growth; and the incidence of adverse events. From January 2007 through February 2011, a total of 21 clinical centers enrolled 608 participants, 6 months to 25 years of age (mean [±SD] age, 11.5±6.5 years in the atenolol group and 11.0±6.2 years in the losartan group), who had an aortic-root z score greater than 3.0. The baseline-adjusted rate of change in the mean (±SE) aortic-root z score did not differ significantly between the atenolol group and the losartan group (-0.139±0.013 and -0.107±0.013 standard-deviation units per year, respectively; P=0.08). Both slopes were significantly less than zero, indicating a decrease in the aortic-root diameter relative to body-surface area with either treatment. The 3-year rates of aortic-root surgery, aortic dissection, death, and a composite of these events did not differ significantly between the two treatment groups. Among children and young adults with Marfan's syndrome who were randomly assigned to losartan or atenolol, we found no significant difference in the rate of aortic-root dilatation between the two treatment groups over a 3-year period. (Funded by the National Heart, Lung, and Blood Institute and others; ClinicalTrials.gov number, NCT00429364.).
[Advantage of delayed umbilical cord clamping in the newborn infant].
Menget, A; Mougey, C; Thiriez, G; Riethmuller, D
2013-09-01
The timing of umbilical cord clamping remains controversial. Although most maternity wards use the early clamping (5-15s), randomized studies and meta-analyses have demonstrated the benefit of delayed clamping for term and preterm newborn infants over the past 10 years. Indeed, placentofetal transfusion of 20-30 ml/kg in 2-3 min improves the iron status of term infants and prevents infant hypochromic anemia. Infant anemia is a public health problem in many developing countries. For preterm newborns, placental transfusion for 45 s or milking the cord for 15 s improves cardiovascular adaptation, with better hemodynamic stability, as well as decreased intraventricular hemorrhages, need for transfusion, and late-onset sepsis. A new look at this symbolic act is needed and professionals need to be persuaded of the importance of the "wait a minute" policy for a better physiological delivery. Copyright © 2013. Published by Elsevier SAS.
Thermal conductance of two interface materials and their applications in space systems
NASA Technical Reports Server (NTRS)
Scialdone, J. J.; Clatterbuck, C. H.; Wall, J. L.
1992-01-01
Two polymeric materials, the Cho-Therm 1671 elastomer and the CV-2946 conductive RTV silicone, have been evaluated. Tests were conducted in vacuum and in air, for many clamping pressures, power densities, and as a function of time. Results obtained show that the CV-2946 thermal conductance after 24 hour in vacuum is 0.62 W/sq cm C(4W/sq in C) when clamped with an average pressure of about 350 psi. The maximum conductance of Cho-Therm 1671 is 4.3 W/sq in C at the clamping pressure about 200 psi. After 72 h in vacuum, the conductance reaches a steady 3.4 W/sq in C, independent of clamping pressure. It is concluded that the tightly bolted, torqued fixtures do not buckle or distort and provide an optimum thermal conductance. The fixtures simulating an actual spacecraft configuration suffered severe bowing and separating, which caused considerable degradation of conductance values.
El Bardai, Sanae; Wibo, Maurice; Hamaide, Marie-Christine; Lyoussi, Badiaa; Quetin-Leclercq, Joëlle; Morel, Nicole
2003-01-01
The objective of the present study was to investigate the mechanism of the relaxant activity of marrubenol, a diterpenoid extracted from Marrubium vulgare. In rat aorta, marrubenol was a more potent inhibitor of the contraction evoked by 100 mM KCl (IC50: 11.8±0.3 μM, maximum relaxation: 93±0.6%) than of the contraction evoked by noradrenaline (maximum relaxation: 30±1.5%). In fura-2-loaded aorta, marrubenol simultaneously inhibited the Ca2+ signal and the contraction evoked by 100 mM KCl, and decreased the quenching rate of fura-2 fluorescence by Mn2+. Patch-clamp data obtained in aortic smooth muscle cells (A7r5) indicated that marrubenol inhibited Ba2+ inward current in a voltage-dependent manner (KD: 8±2 and 40±6 μM at holding potentials of −50 and −100 mV, respectively). These results showed that marrubenol inhibits smooth muscle contraction by blocking L-type calcium channels. PMID:14597602
Diverse effects of a 445 nm diode laser on isometric contraction of the rat aorta
Park, Sang Woong; Shin, Kyung Chul; Park, Hyun Ji; Lee, In Wha; Kim, Hyung-Sik; Chung, Soon-Cheol; Kim, Ji-Sun; Jun, Jae-Hoon; Kim, Bokyung; Bae, Young Min
2015-01-01
The usefulness of visible lasers in treating vascular diseases is controversial. It is probable that multiple effects of visible lasers on blood vessels and their unclear mechanisms have hampered the usefulness of this therapy. Therefore, elucidating the precise actions and mechanisms of the effects of lasers on blood vessels would provide insight into potential biomedical applications. Here, using organ chamber isometric contraction measurements, western blotting, patch-clamp, and en face immunohistochemistry, we showed that a 445 nm diode laser contracted rat aortic rings, both by activating endothelial nitric oxide synthase and by increasing oxidative stress. In addition to the effects on the endothelium, the laser also directly relaxed and contracted vascular smooth muscle by inhibiting L-type Ca2+ channels and by activating protein tyrosine kinases, respectively. Thus, we conclude that exposure to 445 nm laser might contract and dilate blood vessels in the endothelium and smooth muscle via distinct mechanisms. PMID:26417517
Hypothalamic stimulation and baroceptor reflex interaction on renal nerve activity.
NASA Technical Reports Server (NTRS)
Wilson, M. F.; Ninomiya, I.; Franz, G. N.; Judy, W. V.
1971-01-01
The basal level of mean renal nerve activity (MRNA-0) measured in anesthetized cats was found to be modified by the additive interaction of hypothalamic and baroceptor reflex influences. Data were collected with the four major baroceptor nerves either intact or cut, and with mean aortic pressure (MAP) either clamped with a reservoir or raised with l-epinephrine. With intact baroceptor nerves, MRNA stayed essentially constant at level MRNA-0 for MAP below an initial pressure P1, and fell approximately linearly to zero as MAP was raised to P2. Cutting the baroceptor nerves kept MRNA at MRNA-0 (assumed to represent basal central neural output) independent of MAP. The addition of hypothalamic stimulation produced nearly constant increments in MRNA for all pressure levels up to P2, with complete inhibition at some level above P2. The increments in MRNA depended on frequency and location of the stimulus. A piecewise linear model describes MRNA as a linear combination of hypothalamic, basal central neural, and baroceptor reflex activity.
Hanania, G; Michel, P L; Montély, J M; Warembourg, H; Nardi, O; Leguerrier, A; Agnino, A; Despins, P; Legault, B; Petit, H; Bouraindeloup, M
2004-01-01
the aim of this study was to document the choice between prosthesis and bioprosthesis in cases of valvular replacement during the seventh decade of life. a retrospective and cooperative study linking eleven cardiac surgical teams and five medical cardiology teams combined 497 subjects born between 1915 and 1925 (average age 64.4 years) who underwent aortic (313 cases) or mitral (184 cases) valvular replacement with mechanical prosthesis (259 cases) or bioprosthesis (238 cases). Information was collected at each centre during the year 2000 on the long term evolution (going back 15 years), in particular on the mortality, non-fatal complications linked to the valve, cardiac complications and extra-cardiac events. These results were subjected to statistical analysis. the operative mortality of this group was 4.8%. The 15 year survival was 46% for the aortic mechanical prostheses, 32% for the aortic bioprostheses (p=0.04). 34% for the mitral bioprostheses and 33% for the mitral mechanical prostheses. Events linked to the valve were more frequent for the mitral valvulopathies than for the aortic valves (49% vs 26%, p<0.001). The absence of events linked to the valve at 15 years was 69% for the aortic mechanical prostheses and 68% for the aortic bioprostheses. This was the case in only 57% of mitral mechanical prostheses and 36% of the mitral bioprostheses (p=0.11). Thromboembolic accidents were three times more frequent in the mitrals than in the aortics (11.5 vs 3.8%, p=0.002). Haemorrhage was four times more frequent for the mechanical prostheses than for the bioprostheses (7.7 vs 2%, p=0.01). The risk of degeneration for the aortic bioprostheses was 20% at 15 years, three times less so after 65 years of age (p=0.03). At 48% it was much higher in the mitral valves at 15 years with no significant difference before and after 65 years of age (p=0.3). the current life expectancy of subjects in their seventh decade is important. The greatly elevated risk of bioprosthesis degeneration in the mitral position does not allow this alternative to be advocated before 70 years of age. In the aortic position, this risk is elevated before 65 years of age. It is lower after 65 years old. Nevertheless, this means the risk of reoperation in certain octogenarians must be accepted, balanced with the linear risk of haemorrhagic accidents for which a future reduction is expected thanks to milder anticoagulation for aortic mechanical prostheses and anticoagulation autocontrol.
The role of annular dimension and annuloplasty in tricuspid aortic valve repair.
de Kerchove, Laurent; Mastrobuoni, Stefano; Boodhwani, Munir; Astarci, Parla; Rubay, Jean; Poncelet, Alain; Vanoverschelde, Jean-Louis; Noirhomme, Philippe; El Khoury, Gebrine
2016-02-01
Valve sparing reimplantation can improve the durability of bicuspid aortic valve repair compared with subcommissural annuloplasty, especially in patients with a large basal ring. This study analyses the effect of basal ring size and annuloplasty on valve repair in the setting of a tricuspid aortic valve. From 1995 to 2013, 382 patients underwent elective tricuspid aortic valve repair. We included only those undergoing subcommissural annuloplasty, valve sparing reimplantation or no annuloplasty and in whom intraoperative transoesophageal echocardiography images were available for retrospective pre- and post-repair basal ring measurements (n = 323, subcommissural annuloplasty: 146, valve sparing reimplantation: 154, no annuloplasty: 23). In a subgroup of patients with available echocardiographic images, basal ring was retrospectively measured at the latest follow-up or prior to reoperation. subcommissural annuloplasty and valve sparing reimplantation were compared after matching for degree of aortic regurgitation and root size. All three groups differed significantly for most of preoperative characteristics. Hospital mortality was 0.9%. The median follow-up was 4.7 years. At 8 years, overall survival was 80 ± 5%. Freedom from reoperation and freedom from aortic regurgitation >1+ were 92 ± 5% and 71 ± 8%, respectively. In multivariate analysis, predictors of aortic regurgitation >1+ were left ventricular end-diastolic diameter (P = 0.003), cusp repair (P = 0.006), body surface area (P = 0.01) and subcommissural annuloplasty (P = 0.05). In subcommissural annuloplasty, freedom from aortic regurgitation >1+ was lower for patients with basal ring ≥28 mm compared with patients with basal ring <28 mm (P = 0.0001). In valve sparing reimplantation, freedom from aortic regurgitation >1+ was independent of basal ring size (P = 0.38). In matched comparison between subcommissural annuloplasty and valve sparing reimplantation, freedom from aortic regurgitation >1+ was not significantly different (P = 0.06), but in patients with basal ring ≥28 mm, valve sparing reimplantation was superior to subcommissural annuloplasty (P = 0.04). Despite similar intraoperative reduction in basal ring size in subcommissural annuloplasty and valve sparing reimplantation, patients with subcommissural annuloplasty exhibited greater increase in basal ring size during the follow-up compared with the valve sparing reimplantation group (P < 0.001). As with a bicuspid aortic valve, a large basal ring predicts recurrence of aortic regurgitation in patients with tricuspid aortic valve undergoing repair with the subcommissural annuloplasty technique. This recurrence is caused by basal ring dilatation over time after subcommissural annuloplasty. With the valve sparing reimplantation technique, large basal ring did not predict aortic regurgitation recurrence, as prosthetic-based circumferential annuloplasty displayed better stability over time. Stable circumferential annuloplasty is recommended in tricuspid aortic valve repair whenever the basal ring size is ≥28 mm. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Smith, J. Gustav; Luk, Kevin; Schulz, Christina-Alexandra; Engert, James C.; Do, Ron; Hindy, George; Rukh, Gull; Dufresne, Line; Almgren, Peter; Owens, David S.; Harris, Tamara B.; Peloso, Gina M.; Kerr, Kathleen F.; Wong, Quenna; Smith, Albert V.; Budoff, Matthew J.; Rotter, Jerome I.; Cupples, L. Adrienne; Rich, Stephen; Kathiresan, Sekar; Orho-Melander, Marju; Gudnason, Vilmundur; O’Donnell, Christopher J.; Post, Wendy S.; Thanassoulis, George
2014-01-01
IMPORTANCE Plasma low-density lipoprotein cholesterol (LDL-C) has been associated with aortic stenosis in observational studies; however, randomized trials with cholesterol-lowering therapies in individuals with established valve disease have failed to demonstrate reduced disease progression. OBJECTIVE To evaluate whether genetic data are consistent with an association between LDL-C, high-density lipoprotein cholesterol (HDL-C), or triglycerides (TG) and aortic valve disease. DESIGN, SETTING, AND PARTICIPANTS Using a Mendelian randomization study design, we evaluated whether weighted genetic risk scores (GRSs), a measure of the genetic predisposition to elevations in plasma lipids, constructed using single-nucleotide polymorphisms identified in genome-wide association studies for plasma lipids, were associated with aortic valve disease. We included community-based cohorts participating in the CHARGE consortium (n = 6942), including the Framingham Heart Study (cohort inception to last follow-up: 1971-2013; n = 1295), Multi-Ethnic Study of Atherosclerosis (2000-2012; n = 2527), Age Gene/Environment Study-Reykjavik (2000-2012; n = 3120), and the Malmö Diet and Cancer Study (MDCS, 1991-2010; n = 28 461). MAIN OUTCOMES AND MEASURES Aortic valve calcium quantified by computed tomography in CHARGE and incident aortic stenosis in the MDCS. RESULTS The prevalence of aortic valve calcium across the 3 CHARGE cohorts was 32% (n = 2245). In the MDCS, over a median follow-up time of 16.1 years, aortic stenosis developed in 17 per 1000 participants (n = 473) and aortic valve replacement for aortic stenosis occurred in 7 per 1000 (n = 205). Plasma LDL-C, but not HDL-C or TG, was significantly associated with incident aortic stenosis (hazard ratio [HR] per mmol/L, 1.28; 95% CI, 1.04-1.57; P = .02; aortic stenosis incidence: 1.3% and 2.4% in lowest and highest LDL-C quartiles, respectively). The LDL-C GRS, but not HDL-C or TG GRS, was significantly associated with presence of aortic valve calcium in CHARGE (odds ratio [OR] per GRS increment, 1.38; 95% CI, 1.09-1.74; P = .007) and with incident aortic stenosis in MDCS (HR per GRS increment, 2.78; 95% CI, 1.22-6.37; P = .02; aortic stenosis incidence: 1.9% and 2.6% in lowest and highest GRS quartiles, respectively). In sensitivity analyses excluding variants weakly associated with HDL-C or TG, the LDL-C GRS remained associated with aortic valve calcium (P = .03) and aortic stenosis (P = .009). In instrumental variable analysis, LDL-C was associated with an increase in the risk of incident aortic stenosis (HR per mmol/L, 1.51; 95% CI, 1.07-2.14; P = .02). CONCLUSIONS AND RELEVANCE Genetic predisposition to elevated LDL-C was associated with presence of aortic valve calcium and incidence of aortic stenosis, providing evidence supportive of a causal association between LDL-C and aortic valve disease. Whether earlier intervention to reduce LDL-C could prevent aortic valve disease merits further investigation. PMID:25344734
Twenty-year analysis of autologous support of the pulmonary autograft in the Ross procedure.
Skillington, Peter D; Mokhles, M Mostafa; Takkenberg, Johanna J M; O'Keefe, Michael; Grigg, Leeanne; Wilson, William; Larobina, Marco; Tatoulis, James
2013-09-01
The Ross procedure is seldom offered to adults less than 60 years of age who require aortic valve replacement except in a few high-volume centers with documented expertise. Inserting the pulmonary autograft as an unsupported root replacement may lead to increasing reoperations on the aortic valve in the second decade. Of 333 patients undergoing the Ross procedure between October 1992 and June 2012, the study group of 310 consecutive patients (mean age ± standard deviation, 39.3±12.7 years (limits 16-63) had the aortic root size adjusted to match the pulmonary autograft, which was inserted as a root replacement, with the aorta closed up around it to provide autologous support. The mean follow-up time was 9.4 years; the actuarial survival was 97% at 16 years; and freedom from the composite of all reoperations on the aortic valve and late echocardiographic-detected aortic regurgitation greater than mild was 95% at 5 years, 94% at 10 years, and 93% at 15 years. Overall freedom from all reoperations on aortic and pulmonary valves was 97% at 5 years, 94% at 10 years, and 93% at 15 years. All results were better for the patients presenting with predominant aortic stenosis (98% freedom at 15 years) than for those with aortic regurgitation (p=0.01). Autologous support of the pulmonary autograft leads to excellent results in the groups presenting with aortic stenosis and mixed aortic stenosis/regurgitation and to good results for those presenting with pure aortic regurgitation. The Ross procedure, using one of the proven, durable techniques available, should be considered for more widespread adoption. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
The impact of the metabolic syndrome on the outcome after aortic valve replacement.
Tadic, Marijana; Vukadinovic, Davor; Cvijanovic, Dane; Celic, Vera; Kocica, Mladen; Putnik, Svetozar; Ivanovic, Branislava
2014-10-01
The aim of this study was to examine the influence of the metabolic syndrome on the left ventricular geometry as well as on the early and mid-time outcome in patients with aortic stenosis who underwent aortic valve replacement. The study included 182 patients who underwent aortic valve replacement due to aortic stenosis. The metabolic syndrome was defined by the presence of at least three AHA-NHLB (American Heart Association/National Heart, Lung and Blood Institute) criteria. All the patients were followed for at least 2 years after the surgery. The metabolic syndrome did not influence the severity of aortic stenosis (mean gradient and aortic valve area). However, the metabolic syndrome was associated with the reduced prevalence of the normal left ventricular geometry and the increased risk of concentric left ventricular hypertrophy in patients with aortic stenosis. Among the metabolic syndrome criteria, only increased blood pressure was simultaneously associated with the short-term and mid-term outcome, independently of other risk factors. Increased fasting glucose level was an independent predictor of the only 30-day outcome after the valve replacement. The metabolic syndrome and left ventricular hypertrophy were, independently of hypertension and diabetes, associated with the 30-day outcome, as well as incidence of major cerebrovascular and cardiovascular events in the 2-year postoperative period. The metabolic syndrome does not change severity of the aortic stenosis, but significantly impacts the left ventricular remodeling in these patients. The metabolic syndrome and left ventricular hypertrophy, irrespective of hypertension and diabetes, are predictors of the short-term and mid-term outcome of patients with aortic stenosis who underwent aortic valve replacement.
Ahmad, Amier; McElwee, Samuel K; Jiang, Amy Z; Barssoum, Kirolos N; Elkaryoni, Ahmed E; Arisha, Mohammed J; Srialluri, Swetha; Seghatol, Frank; Nanda, Navin C
2017-02-01
Paraprosthetic aortic valve abscess represents a rare, but lethal complication of infective endocarditis. We report a case of proximal left coronary system compression by a paraprosthetic aortic valve abscess whose detection was augmented using live/real time three-dimensional transesophageal echocardiography. Our case illustrates the usefulness of combined two- and three-dimensional transesophageal echocardiography in detecting this finding. © 2017, Wiley Periodicals, Inc.
Prediction of aortic valvular area and gradient by noninvasive techniques.
Cousins, A L; Eddleman, E E; Reeves, T J
1978-03-01
Sixty-two patients with isolated aortic valvular stenosis were analyzed by a series of common noninvasive procedures and by cardiac catheterization. The data from 50 of these were evaluated in a retrospective fashion by multiple regression methods to determine significant objectively obtained predictors of aortic-left ventricular gradient and valvular area. Formulae were derived from these analyses and an additional 12 patients were then studied prospectively to evaluate the validity of the predictive formulae. Forty-three of 50 patients (86 per cent) were correctly identified as to a gradient of greater or less than 50 mm. Hg in the initial group, and all those in the prospectively studied sample were correctly classified. Thiry-five of 43 patients (82 per cent) of those with valve area data in the first application were correctly classified as to valve area or greater or less than 0.8 cm.2, and all patients in the prospectively studied group were appropriately identified as to the same area. The combined application of the observations of calcification of the aortic valve, shudder waves on the anacrotic limb, prolonged time to peak of the percussion wave and alteration of the dicrotic notch of the carotid pulse tracing, left ventricular hypertrophy by electrocardiogram, and the altered duration of ventricular ejection time were reliable predictors of elevated aortic-left ventricular gradient and decreased aortic valvular size.
Poloxamer 188 decreases susceptibility of artificial lipid membranes to electroporation.
Sharma, V; Stebe, K; Murphy, J C; Tung, L
1996-01-01
The effect of a nontoxic, nonionic block co-polymeric surface active agent, poloxamer 188, on electroporation of artificial lipid membranes made of azolectin, was investigated. Two different experimental protocols were used in our study: charge pulse and voltage clamp. For the charge pulse protocol, membranes were pulsed with a 10-micronsecond rectangular voltage waveform, after which membrane voltage decay was observed through an external 1-M omega resistance. For the voltage clamp protocol the membranes were pulsed with a waveform that consisted of an initial 10-microsecond rectangular phase, followed by a negative sloped ramp that decayed to zero in the subsequent 500 microseconds. Several parameters characterizing the electroporation process were measured and compared for the control membranes and membranes treated with 1.0 mM poloxamer 188. For both the charge pulse and voltage clamp experiments, the threshold voltage (amplitude of initial rectangular phase) and latency time (time elapsed between the end of rectangular phase and the onset of membrane electroporation) were measured. Membrane conductance (measured 200 microseconds after the initial rectangular phase) and rise time (tr; the time required for the porated membrane to reach a certain conductance value) were also determined for the voltage clamp experiments, and postelectroporation time constant (PE tau; the time constant for transmembrane voltage decay after onset of electroporation) for the charge pulse experiments. The charge pulse experiments were performed on 23 membranes with 10 control and 13 poloxamer-treated membranes, and voltage pulse experiments on 49 membranes with 26 control and 23 poloxamer-treated membranes. For both charge pulse and voltage clamp experiments, poloxamer 188-treated membranes exhibited a statistically higher threshold voltage (p = 0.1 and p = 0.06, respectively), and longer latency time (p = 0.04 and p = 0.05, respectively). Also, poloxamer 188-treated membranes were found to have a relatively lower conductance (p = 0.001), longer time required for the porated membrane to reach a certain conductance value (p = 0.05), and longer postelectroporation time constant (p = 0.005). Furthermore, addition of poloxamer 188 was found to reduce the membrane capacitance by approximately 4-8% in 5 min. These findings suggest that poloxamer 188 adsorbs into the lipid bilayers, thereby decreasing their susceptibility to electroporation. Images FIGURE 1 PMID:8968593
De Paco, Catalina; Herrera, Javier; Garcia, Carolina; Corbalán, Shiana; Arteaga, Alicia; Pertegal, Miriam; Checa, Rosario; Prieto, María Teresa; Nieto, Aníbal; Delgado, Juan Luis
2016-12-01
To compare the time in the third stage of labour, differences in maternal hematologic parameters 48h after birth and acid-base status in the umbilical cord between the early cord clamping (ECC) and delayed cord clamping (DCC). 97 healthy pregnancies at term and a spontaneous vertex delivery at Clinic University Hospital "Virgen de la Arrixaca" (Murcia, Spain), were randomized to ECC group (<10s post-delivery) or to DCC group (2min post-delivery). Duration of the third stage of labour was measured. Samples for acid-base status were taken both from the umbilical artery and vein. Blood samples were taken from the mothers 48h after birth. No statistical differences were found in the time of the third stage of labour (p=0.35). No statiscally significant differences were found between the number of red cells (p=0.25), hemoglobin (p=0.08) or hematocrit (p=0.15) in mothers. Umbilical acid-base status or gas analysis did not show any differences between the two groups CONCLUSIONS: Delayed cord clamping does not affect significantly the time of the third stage of labour. It does not show either any effect on the hematological parameters in the mother 48h after birth. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Auxiliary quasi-resonant dc tank electrical power converter
Peng, Fang Z.
2006-10-24
An auxiliary quasi-resonant dc tank (AQRDCT) power converter with fast current charging, voltage balancing (or charging), and voltage clamping circuits is provided for achieving soft-switched power conversion. The present invention is an improvement of the invention taught in U.S. Pat. No. 6,111,770, herein incorporated by reference. The present invention provides faster current charging to the resonant inductor, thus minimizing delay time of the pulse width modulation (PWM) due to the soft-switching process. The new AQRDCT converter includes three tank capacitors or power supplies to achieve the faster current charging and minimize the soft-switching time delay. The new AQRDCT converter further includes a voltage balancing circuit to charge and discharge the three tank capacitors so that additional isolated power supplies from the utility line are not needed. A voltage clamping circuit is also included for clamping voltage surge due to the reverse recovery of diodes.
Aortic wrapping for a dilated ascending aorta in bicuspid aortic stenosis.
Choi, Min Suk; Jeong, Dong Seop; Lee, Hae Young; Sung, Kiick; Kim, Wook Sung; Lee, Young Tak; Park, Pyo Won
2015-01-01
Ascending aorta wrapping is rarely recommended for the management of dilated aorta, because of late complications. The aim of the present study was to analyze the early and late outcomes of the aortic wrapping technique at the time of aortic valve replacement (AVR) for bicuspid aortic stenosis (BAS). Among patients who underwent primary AVR for BAS between 2002 and 2011, 79 who underwent ascending aortic wrapping (wrapping group) were compared with 144 patients who underwent AVR alone. The preoperative ascending aortic diameters were larger in the wrapping group (40.9±4.2 mm vs. 48.6±4.0 mm, P<0.001). Operative technique was to wrap the ascending aorta transversely with a semi-elliptically resected Dacron graft. The follow-up for the wrapping group was 76.5±35.5 (median 71.1) months. There were no early deaths. Early and late morbidity did not differ between groups. The 24 late deaths, including 10 cardiac-related deaths, occurred in the entire group; 3 sudden deaths occurred only in the AVR group. The 10-year overall survival in the wrapping group was higher than the AVR group (88.1±6.8% vs. 80.0±4.6%, P=0.048). No late aortic complications were detected. The aortic diameter was reduced from 49.5±4.1 mm to 45.3±5.0 mm after wrapping (P<0.001). The aortic wrapping technique may be an option for treating a moderately dilated ascending aorta in selected patients undergoing AVR for BAS. Longer follow-up, however, is necessary to verify later complications.
Triple bar, high efficiency mechanical sealer
Pak, Donald J.; Hawkins, Samantha A.; Young, John E.
2013-03-19
A clamp with a bottom clamp bar that has a planar upper surface is provided. The clamp may also include a top clamp bar connected to the bottom clamp bar, and a pressure distribution bar between the top clamp bar and the bottom clamp bar. The pressure distribution bar may have a planar lower surface in facing relation to the upper surface of the bottom clamp bar. An object is capable of being disposed in a clamping region between the upper surface and the lower surface. The width of the planar lower surface may be less than the width of the upper surface within the clamping region. Also, the pressure distribution bar may be capable of being urged away from the top clamp bar and towards the bottom clamp bar.
Veerman, Christiaan C.; Zegers, Jan G.; Mengarelli, Isabella; Bezzina, Connie R.
2017-01-01
Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great promise for studying inherited cardiac arrhythmias and developing drug therapies to treat such arrhythmias. Unfortunately, until now, action potential (AP) measurements in hiPSC-CMs have been hampered by the virtual absence of the inward rectifier potassium current (IK1) in hiPSC-CMs, resulting in spontaneous activity and altered function of various depolarising and repolarising membrane currents. We assessed whether AP measurements in “ventricular-like” and “atrial-like” hiPSC-CMs could be improved through a simple, highly reproducible dynamic clamp approach to provide these cells with a substantial IK1 (computed in real time according to the actual membrane potential and injected through the patch-clamp pipette). APs were measured at 1 Hz using perforated patch-clamp methodology, both in control cells and in cells treated with all-trans retinoic acid (RA) during the differentiation process to increase the number of cells with atrial-like APs. RA-treated hiPSC-CMs displayed shorter APs than control hiPSC-CMs and this phenotype became more prominent upon addition of synthetic IK1 through dynamic clamp. Furthermore, the variability of several AP parameters decreased upon IK1 injection. Computer simulations with models of ventricular-like and atrial-like hiPSC-CMs demonstrated the importance of selecting an appropriate synthetic IK1. In conclusion, the dynamic clamp-based approach of IK1 injection has broad applicability for detailed AP measurements in hiPSC-CMs. PMID:28867785
NASA Astrophysics Data System (ADS)
Hatoum, Hoda; Dasi, Lakshmi Prasad
2017-11-01
Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.
NASA Technical Reports Server (NTRS)
Ramsey, John K. (Inventor); Meyn, Erwin H. (Inventor)
1990-01-01
A pair of spaced collars are mounted at right angles on a clamp body by retaining rings which enable the collars to rotate with respect to the clamp body. Mounting posts extend through aligned holes in the collars and clamp body. Each collar can be clamped onto the inserted post while the clamp body remains free to rotate about the post and collar. The clamp body is selectively clamped onto each post.
Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki
2018-01-01
The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.
The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta
NASA Astrophysics Data System (ADS)
Ha, Hojin; Kim, Guk Bae; Kweon, Jihoon; Lee, Sang Joon; Kim, Young-Hak; Kim, Namkug; Yang, Dong Hyun
2016-08-01
Since the first observation of a helical flow pattern in aortic blood flow, the existence of helical blood flow has been found to be associated with various pathological conditions such as bicuspid aortic valve, aortic stenosis, and aortic dilatation. However, an understanding of the development of helical blood flow and its clinical implications are still lacking. In our present study, we hypothesized that the direction and angle of aortic inflow can influence helical flow patterns and related hemodynamic features in the thoracic aorta. Therefore, we investigated the hemodynamic features in the thoracic aorta and various aortic inflow angles using patient-specific vascular phantoms that were generated using a 3D printer and time-resolved, 3D, phase-contrast magnetic resonance imaging (PC-MRI). The results show that the rotational direction and strength of helical blood flow in the thoracic aorta largely vary according to the inflow direction of the aorta, and a higher helical velocity results in higher wall shear stress distributions. In addition, right-handed rotational flow conditions with higher rotational velocities imply a larger total kinetic energy than left-handed rotational flow conditions with lower rotational velocities.
The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta.
Ha, Hojin; Kim, Guk Bae; Kweon, Jihoon; Lee, Sang Joon; Kim, Young-Hak; Kim, Namkug; Yang, Dong Hyun
2016-08-26
Since the first observation of a helical flow pattern in aortic blood flow, the existence of helical blood flow has been found to be associated with various pathological conditions such as bicuspid aortic valve, aortic stenosis, and aortic dilatation. However, an understanding of the development of helical blood flow and its clinical implications are still lacking. In our present study, we hypothesized that the direction and angle of aortic inflow can influence helical flow patterns and related hemodynamic features in the thoracic aorta. Therefore, we investigated the hemodynamic features in the thoracic aorta and various aortic inflow angles using patient-specific vascular phantoms that were generated using a 3D printer and time-resolved, 3D, phase-contrast magnetic resonance imaging (PC-MRI). The results show that the rotational direction and strength of helical blood flow in the thoracic aorta largely vary according to the inflow direction of the aorta, and a higher helical velocity results in higher wall shear stress distributions. In addition, right-handed rotational flow conditions with higher rotational velocities imply a larger total kinetic energy than left-handed rotational flow conditions with lower rotational velocities.
The influence of the aortic valve angle on the hemodynamic features of the thoracic aorta
Ha, Hojin; Kim, Guk Bae; Kweon, Jihoon; Lee, Sang Joon; Kim, Young-Hak; Kim, Namkug; Yang, Dong Hyun
2016-01-01
Since the first observation of a helical flow pattern in aortic blood flow, the existence of helical blood flow has been found to be associated with various pathological conditions such as bicuspid aortic valve, aortic stenosis, and aortic dilatation. However, an understanding of the development of helical blood flow and its clinical implications are still lacking. In our present study, we hypothesized that the direction and angle of aortic inflow can influence helical flow patterns and related hemodynamic features in the thoracic aorta. Therefore, we investigated the hemodynamic features in the thoracic aorta and various aortic inflow angles using patient-specific vascular phantoms that were generated using a 3D printer and time-resolved, 3D, phase-contrast magnetic resonance imaging (PC-MRI). The results show that the rotational direction and strength of helical blood flow in the thoracic aorta largely vary according to the inflow direction of the aorta, and a higher helical velocity results in higher wall shear stress distributions. In addition, right-handed rotational flow conditions with higher rotational velocities imply a larger total kinetic energy than left-handed rotational flow conditions with lower rotational velocities. PMID:27561388
Hosein, Riad B M; Mehta, Chetan; Stickley, John; Mcguirk, Simon P; Jones, Timothy J; Brawn, William J; Barron, David J
2007-11-01
A small sub-group of patients with hypoplastic left heart syndrome (HLHS) have normal-sized ascending aorta and arch. An alternative to the Norwood I procedure in these patients is the creation of an aorto-pulmonary (AP) window with a distal pulmonary artery band (PAB). We reviewed our experience with this technique and compared outcomes to the Norwood procedure for HLHS. All patients treated for HLHS in a single institution between 1992 and 2005 were analysed. This identified 13 patients treated with AP window and PAB compared to 333 patients undergoing stage I Norwood procedure. An unrestrictive AP window was created and the main PA was banded. Patient records and echocardiograms were analysed. Median follow-up was 10 (IQR 0-655) days and 100% complete. There were seven early deaths (54%) in the AP window group and two conversions to Norwood circulation. This was a significantly worse outcome than for the Norwood procedure over the same period, which had an early mortality of 29% (p=0.03). Kaplan-Meier actuarial analysis demonstrated a continued survival benefit of the Norwood group at 6 months (p=0.0005). Deaths were due to either low cardiac output syndrome (n=4) or sudden unheralded arrest (n=3). This occurred despite aortic cross-clamp and circulatory arrest times being significantly lower in the AP window group compared to the Norwood group (35+/-27 vs 55+/-16 min, p<0.01 and 16+/-29 vs 55+/-20 min, p<0.01, respectively). No differences in arterial saturations or systolic blood pressure existed between the groups, but diastolic blood pressure was significantly lower in the AP window group at 27+/-10 mmHg compared to 42+/-8 mmHg in the Norwood group (p=0.01) with evidence of flow reversal in the descending aorta. Differences in diastolic blood pressure between groups were abolished after conversion to stage II. Despite favourable anatomy and shorter ischaemic times, the AP window/PAB technique has a poor outcome compared to the Norwood procedure for HLHS. Low diastolic blood pressure with reversal of descending aortic flow in diastole was a feature of the AP window/PAB circulation. We recommend the Norwood procedure for these sub-types. This may have implications for newer 'hybrid' procedures for HLHS which create a similar palliative circulation.
NASA Astrophysics Data System (ADS)
Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan
2016-03-01
Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.
Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan
2016-03-01
Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.
Kim, Y J; Jones, M; Shiota, T; Tsujino, H; Qin, J X; Bauer, F; Sitges, M; Kwan, J; Cardon, L A; Zetts, A D; Thomas, J D
2002-10-01
To evaluate the load dependence of effective regurgitant orifice area (ROA) in an animal model of chronic aortic regurgitation. Eight sheep were studied 10-20 weeks after the surgical creation of aortic regurgitation. After baseline studies, 500 ml of blood, angiotensin II, and nitroprusside were infused sequentially. Electromagnetic flow meters were used as reference standards to determine aortic regurgitation volume. The time-velocity integral was acquired using the continuous wave Doppler method. Baseline aortic regurgitant volume varied from 8 ml (regurgitant fraction 28%) to 29 ml (59%), with a mean (SD) value of 17 (8) ml; mean ROA was 0.15 (0.05) cm2. During angiotensin II infusion, aortic regurgitation volume (20 (8) ml) and mean diastolic aortoventricular pressure gradient (62 (18) mm Hg) increased by 26 (16)% and 48 (64)%, respectively (p < 0.01 for both). ROA did not change (0.16 (0.06) cm(2), p = 0.15). During nitroprusside infusion, aortic regurgitant volume (13 (7) ml, p = 0.05) and diastolic pressure gradient (25 (13) mm Hg, p < 0.05) decreased. ROA did not change (0.15 (0.05) cm2). When analysing 32 stages together, aortic regurgitant volume (r = 0.78, p < 0.01) and regurgitant fraction (r = 0.55, p < 0.01) correlated well with ROA. However, diastolic pressure gradient (r = 0.28) was not significantly correlated with ROA. In an animal model of chronic aortic regurgitation, ROA did not change with load alterations.
Propper, Brandon W; Alley, Joshua B; Gifford, Shaun M; Burkhardt, Gabriel E; Rasmussen, Todd E
2009-01-01
The management of blunt descending thoracic aortic injury remains controversial. Despite emerging evidence touting the advantage of endovascular repair in civilian trauma, there have been no reports on the application of this management strategy in the austere environment of war. We provide a case report from the 332nd EMDG/Air Force Theater Hospital, Balad Air Base, Iraq. An Iraqi policeman presented with traumatic aortic disruption following blunt trauma. The patient arrived with hemoperitoneum, a Le Fort III facial fracture, a left humerus fracture, and a thoracic aortic disruption. Following facial packing, fracture stabilization, and damage control laparotomy, aortography was performed, confirming aortic disruption beyond the left subclavian artery. The injury was treated with three aortic cuffs (Gore Excluder AAA Aortic Extender Endoprostheses) placed in sequence from the origin of the left subclavian across the disruption. A type III endoleak was successfully managed with placement of one additional aortic cuff. The patient was discharged after 1 month following the successful treatment of his other injuries. Computed tomography angiography at 10 and 30 days following the procedure revealed no endoleak and a resolved periaortic hematoma. This report details the first endovascular treatment of blunt aortic injury in wartime and represents a sustained commitment to advance innovative endovascular capability closer to the time of injury. Although controversial, this less invasive approach is appealing in patients with high injury severity scores, making its availability in wartime especially germane.
Long-term outcome of large artificial patch aortic repair for diffuse stenosis in Williams syndrome.
Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Sakurai, Manabu; Aoki, Chikashi
2010-10-01
There have been only a few reports concerning the long-term results of a surgical procedure using a large artificial patch for patients with Williams syndrome. Twelve years have passed since a patient with William's syndrome underwent a surgery with a patch angioplasty for the diffuse supravalvular aortic stenosis and deformities of the neck branch arteries. The patient had a well-balanced aortic growth without stenotic or aneurysmal changes, which was confirmed during the time of the second surgery when replacing the mitral valve. This technique of using a large patch has proven to be safe for Williams syndrome patients with diffuse supravalvular aortic stenosis in the long term.
Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean
2011-01-01
Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.
Lintz, José Alves; Dalio, Marcelo Bellini; Tirapelli, Luiz Fernando; Ribeiro, Maurício Serra; Joviliano, Edwaldo Edner; Piccinato, Carlos Eli
2017-04-01
Analyze the effects of ischemic postconditioning on skeletal muscle injury and apoptosis produced by partial ischemia and reperfusion in rats. An experimental study was designed using 70 Wistar rats divided in 3 groups: Sham; Control-submitted to ischemia and reperfusion; and Postconditioning-submitted to ischemia and reperfusion with ischemic postconditioning. Subgroups (n = 10) were divided by duration of ischemia (4, 5, or 6 hr). A partial ischemia model using aortic clamping was used. The postconditioning protocol consisted of 3 cycles of clamping the aorta for 1 min and releasing for another minute. Skeletal muscle injury was evaluated by measuring serum levels of releasing cytoplasmic enzymes: aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and total creatine phosphokinase (CPK). Lipid peroxidation was evaluated by muscular levels of malondialdehyde (MDA). Energetic cell storage was evaluated by muscular glycogen levels. Apoptosis was evaluated analyzing the expression of caspase 3 and protein B-cell lymphoma 2 (Bcl-2) by immunohistochemistry. AST levels in Sham group were 109.80 units/L, in Control subgroups were 4h 200.60 units/L/5h 392.30 units/L/6h 118.82 units/L, whereas in Postconditioning subgroups were: 4h 316.10 units/L/5h 268.40 units/L/6h 267.00 units/L. There was a 2-3-fold increase in Control and Postconditioning groups compared with Sham group (P = 0.003) There was no difference between groups with the same ischemic injury time. LDH, CPK, and MDA levels were similar in Sham, Control, and Postconditioning groups. Subgroups with the same ischemic injury time were also similar. Glycogen levels in Sham group were 0.629 mg%, in Control subgroups were 4h 0.323 mg%/5h 0.348 mg%/6h 0.183 mg%, whereas in Postconditioning subgroups were: 4h 0.443 mg%/5h 0.270 mg%/6h 0.324 mg%. Control and Postconditioning groups were decreased by half in relation with the Sham group (P = 0.002), with no difference between groups with the same ischemic injury time. For both caspase 3 and Bcl-2, the percentage of positive cells increased more than 2-fold in Control and Postconditioning groups when compared with Sham group (P < 0.001). The greater the ischemic injury time, the greater was the percent of positive cells (P < 0.0005), with no difference between subgroups with the same ischemic injury time. Ischemic postconditioning had neither protective effect on skeletal muscle injury nor avoided apoptosis induction in rats submitted to partial ischemia and reperfusion. Copyright © 2017 Elsevier Inc. All rights reserved.
Akça, Barış; Erdil, Nevzat; Colak, Mehmet Cengiz; Disli, Olcay Murat; Battaloglu, Bektas; Colak, Cemil
2018-03-06
We aimed to investigate the risk factors of post-coronary artery bypass grafting (CABG) atrial fibrillation (AF) in male and female patients without any history of AF, to identify the sex-specific risk factors, and to examine the effect of sex-specific risk factors on the overall population. This retrospective study was conducted using the hospital database with 4,758 patients who underwent CABG surgery. Among them, 2,836 patients with complete data participated in this study. The female patients were divided into two groups as patients who developed new-onset AF after CABG and those who did not. The relationship between the patients' variables and risk factors of post-CABG AF was examined. The overall incidence of post CABG AF was 12.9% (386/2,836). Sex-specific incidence of AF was similar: 3.2% (91/690) and 12.9% (277/2146) in female and male patients, respectively ( p = 0.849). Multiple analysis revealed the independent risk factors for male and female patients, respectively: mean age (odds ratio [OR] = 1.057, OR = 1,076), age over 65 years (OR = 2.156, OR = 2.736), the European System For Cardiac Operative Risk Evaluation Scores (EuroSCORE) (OR = 1.13, OR = 1.218), COPD (OR = 1.589, OR = 1.789), BUN level (OR = 1.026, OR = 1.019), mean cardiopulmonary bypass (CPB) time (OR = 1.007, OR = 1.010), prolonged CPB time (OR = 1.604, OR = 2.309), mean cross-clamp time (OR = 1.009, OR = 1.017), need of inotropic support (OR = 2.249, OR = 2.731), and mean mechanical ventilation time (VT) (OR = 1.026, OR = 1.027).Low left ventricular ejection fraction (LVEF) (OR = 1.419), left ventricular (LV) aneurysm repair (OR = 1.533), carotid artery disease (OR = 1.750), prolonged VT (OR = 1.729), and use of intra-aortic balloon pump (IABP) (OR = 2.436) were found to be the risk factors only for male AF patients.Unstable angina (OR = 1.969), right coronary artery (RCA) disease (OR = 2), prolonged cross-clamp time (OR = 2.152), and the number of grafts per operation (OR = 1.298) were found to be the risk factors only for female AF patients. This study suggests that predictors of AF in the overall population may be due to isolated patient groups. Multiple regression analysis and artificial intelligence modelling should be performed on large-scale, isolated groups to make strong AF prediction. Georg Thieme Verlag KG Stuttgart · New York.
Medium-term outcome of Toronto aortic valve replacement: single center experience.
Li, Wei; Price, Susanna; O'Sullivan, Christine A; Kumar, Pankaj; Jin, Xu Y; Henein, Michael Y; Pepper, John R
2008-09-26
Long-term competence of any aortic prosthesis is critical to its clinical durability. Bioprosthetic valves, and in particular the stentless type have been proposed to offer superior haemodynamic profiles with consequent potential for superior left-ventricular mass regression. These benefits however are balanced by the potential longevity of the implanted valve. The aims of this study were to assess medium-term Toronto aortic valve function and its effect on left-ventricular function. Between 1992 and 1996 86 patients underwent Toronto aortic valve replacement for aortic valve disease and were followed up annually. Prospectively collected data was analyzed for all patients where detailed echocardiographic follow-up was available. Echocardiographic studies were analyzed at 2+/-0.6 and 6+/-1.4 years after valve replacement. Data collected included left-ventricular systolic and diastolic dimensions, fractional shortening and left-ventricular mass. In addition, data on aortic valve and root morphology, peak aortic velocities, time velocity integral, stroke volume and the mechanism of valve failure where relevant, were also collected. Complete echocardiographic data were available for eighty-four patients, age 69+/-9 years, 62 male. Additional coronary artery bypass grafting was performed in 38% of patients. Twelve (14%) valves had failed during follow-up, 7 (8%) requiring re-operation. Valve failure was associated with morphologically bicuspid native aortic valve (9/12), and progressive dilatation of the aortic sinuses, sino-tubular junction and ascending aorta (11/12). Left-ventricular mass index remained high (184+/-75 g/m(2)) and did not continue to regress between early and medium-term follow-up (175.8+/-77 g/m(2)). Although more than 90% of implanted Toronto aortic valves remained haemodynamically stable with low gradient at medium-term follow-up, young age and larger aortic dimensions in patients with valve failure suggest better outcome if used in the elderly with normal aortic root geometry.
King, Sibella G; Ahuja, Kiran D K; Wass, Jezreel; Shing, Cecilia M; Adams, Murray J; Davies, Justin E; Sharman, James E; Williams, Andrew D
2013-05-01
Aortic pulse wave velocity (PWV) and augmentation index (AIx) are independent predictors of cardiovascular risk and mortality, but little is known about the effect of air temperature changes on these variables. Our study investigated the effect of exposure to whole-body mild-cold on measures of arterial stiffness (aortic and brachial PWV), and on central haemodynamics [including augmented pressure (AP), AIx], and aortic reservoir components [including reservoir and excess pressures (P ex)]. Sixteen healthy volunteers (10 men, age 43 ± 19 years; mean ± SD) were randomised to be studied under conditions of 12 °C (mild-cold) and 21 °C (control) on separate days. Supine resting measures were taken at baseline (ambient temperature) and after 10, 30, and 60 min exposure to each experimental condition in a climate chamber. There was no significant change in brachial blood pressure between mild-cold and control conditions. However, compared to control, AP [+2 mmHg, 95 % confidence interval (CI) 0.36-4.36; p = 0.01] and AIx (+6 %, 95 % CI 1.24-10.1; p = 0.02) increased, and time to maximum P ex (a component of reservoir function related to timing of peak aortic in-flow) decreased (-7 ms, 95 % CI -15.4 to 2.03; p = 0.01) compared to control. Yet there was no significant change in aortic PWV (+0.04 m/s, 95 % CI -0.47 to 0.55; p = 0.87) or brachial PWV (+0.36 m/s; -0.41 to 1.12; p = 0.35) between conditions. We conclude that mild-cold exposure increases central haemodynamic stress and alters timing of peak aortic in-flow without differentially affecting arterial stiffness.
Verhoye, Jean-Philippe; Belhaj Soulami, Reda; Fouquet, Olivier; Ruggieri, Vito Giovanni; Kaladji, Adrien; Tomasi, Jacques; Sellin, Michel; Farhat, Fadi; Anselmi, Amedeo
2017-10-01
Our goal was to evaluate the operative outcomes of the frozen elephant trunk technique using the E-Vita Open Plus® hybrid prosthesis in chronic aortic arch diseases and report clinical and radiological outcomes at the 1-year follow-up. As determined from a prospective multicentre registry, 94 patients underwent frozen elephant trunk procedures using the E-Vita Open Plus hybrid device for the treatment of chronic aortic conditions, including 50% chronic aortic dissections, 40% degenerative aneurysms and 10% miscellaneous indications. Fifty percent of the cases were reoperations. The perioperative mortality rate was 11.7%. Spinal cord ischaemia and stroke rates were 4% and 9.6%, respectively. The mean cardiopulmonary bypass time was 252 ± 97 min, cardiac ischaemia time was 152 ± 53 min and cerebral perfusion time was 82 ± 22 min. Concomitant procedures were observed in 15% of patients. Among the 83 surviving patients, the survival rate after the 1-year follow-up was 98%. Eleven percent of patients underwent endovascular completion, whereas 4% of patients required aortic reintervention at 1 year. The E-Vita Open Plus hybrid device confirms the favourable short- and mid-term outcomes offered by its predecessor in frozen elephant trunk procedures in patients with chronic aortic arch disease. Implantation of the E-Vita Open Plus is associated with good 1-year survival rates, good rates of favourable aortic remodelling in both chronic dissection and degenerative aneurysms and a reproducible technique in a multicentre registry. Continued follow-up is required due to the risk of evolution at the downstream aorta. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Eide, Leslie S P; Ranhoff, Anette H; Fridlund, Bengt; Haaverstad, Rune; Kuiper, Karel K J; Nordrehaug, Jan Erik; Norekvål, Tone M
2016-01-01
Objectives To determine whether postoperative delirium predicts first-time readmissions and mortality in octogenarian patients within 180 days after aortic valve therapy with surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI), and to determine the most common diagnoses at readmission. Design Prospective cohort study of patients undergoing elective SAVR or TAVI. Setting Tertiary university hospital that performs all SAVRs and TAVIs in Western Norway. Participants Patients 80+ years scheduled for SAVR or TAVI and willing to participate in the study were eligible. Those unable to speak Norwegian were excluded. Overall, 143 patients were included, and data from 136 are presented. Primary and secondary outcome measures The primary outcome was a composite variable of time from discharge to first all-cause readmission or death. Secondary outcomes were all-cause first readmission alone and mortality within 180 days after discharge, and the primary diagnosis at discharge from first-time readmission. Delirium was assessed with the confusion assessment method. First-time readmissions, diagnoses and mortality were identified in hospital information registries. Results Delirium was identified in 56% of patients. The effect of delirium on readmissions and mortality was greatest during the first 2 months after discharge (adjusted HR 2.9 (95% CI 1.5 to 5.7)). Of 30 first-time readmissions occurring within 30 days, 24 (80%) were patients who experienced delirium. 1 patient (non-delirium group) died within 30 days after therapy. Delirious patients comprised 35 (64%) of 55 first-time readmissions occurring within 180 days. Circulatory system diseases and injuries were common causes of first-time readmissions within 180 days in delirious patients. 8 patients died 180 days after the procedure; 6 (75%) of them experienced delirium. Conclusions Delirium in octogenarians after aortic valve therapy might be a serious risk factor for postoperative morbidity and mortality. Cardiovascular disorders and injuries were associated with first-time readmissions in these patients. PMID:27707832
Voltage-Clamp Studies on Uterine Smooth Muscle
Anderson, Nels C.
1969-01-01
These studies have developed and tested an experimental approach to the study of membrane ionic conductance mechanisms in strips of uterine smooth muscle. The experimental and theoretical basis for applying the double sucrose-gap technique is described along with the limitations of this system. Nonpropagating membrane action potentials were produced in response to depolarizing current pulses under current-clamp conditions. The stepwise change of membrane potential under voltage-clamp conditions resulted in a family of ionic currents with voltage- and time-dependent characteristics. In sodium-free solution the peak transient current decreased and its equilibrium potential shifted along the voltage axis toward a more negative internal potential. These studies indicate a sodium-dependent, regenerative excitation mechanism. PMID:5796366
Furukawa, K; Ohteki, H; Doi, K
1997-10-01
We report a successful result of treatment for a ruptured thoracoabdominal aortic aneurysm with aortitis syndrome. A 43-year-old male suffered sudden low back pain, that was diagnosed as a ruptured thoracoabdominal aortic aneurysm based on abdominal computed tomography. Preoperative angiography revealed a thoracoabdominal aortic aneurysm with occlusion of the superior mesenteric artery, and well developed Riolan's archade. The aneurysm was replaced by a prosthetic graft with partial femoro-femoral bypass in conjunction with selective cold perfusion for the visceral arteries. Total extracorporeal circulation time, and aortic clamptime, was 187 minutes and 132 minutes, respectively. The postoperative courses of liver and renal function were excellent. The patient recovered from surgery uneventfully. It was suggested that selective cold visceral perfusion was effective for prevention of renal and liver dysfunction associated with a ruptured thoracoabdominal aneurysm.
Effect of sterilization on stiffness and dimensional stability of rubber-dam clamps.
Giebink, D L; Mathieu, G P; Hondrum, S O
1996-01-01
Simulated clinical conditions were used to test the effect of sterilization on rubber-dam clamp stiffness and dimension. Sixty Hygienic and Ivory W7 clamps were either steam or dry heat sterilized and compared to controls. Stiffness and dimensional change between Ivory clamp groups was significant (p<.0001); the sterilized clamps showed less change than the controls. Hygienic groups showed a significant different between the control and dry heat groups (p<.05); the sterilized clamps showed less change than the controls. The change in stiffness and interjaw width for all Ivory clamps compared to all Hygienic clamps was significant (p<.0001). The Hygienic clamps changes less than the Ivory clamps. The results indicate that steam and dry heat sterilization do not affect retention of rubber-dam clamps.
Impact of timing and surgical approach on outcomes after mitral valve regurgitation operations.
Stevens, Louis-Mathieu; Rodriguez, Evelio; Lehr, Eric J; Kindell, Linda C; Nifong, L Wiley; Ferguson, T Bruce; Chitwood, W Randolph
2012-05-01
This study investigated whether the timing of mitral valve (MV) repair or surgical approach affects outcomes in patients with MV regurgitation. Between 1992 and 2009, 2,255 patients underwent MV operations, including 1,305 with isolated MV regurgitation operations (1,054 repairs, 251 replacements). Surgical approaches were sternotomy in 377, video-assisted right minithoracotomy in 481, or robot-assisted in 447. Mean follow-up was 6.4±4.5 years (maximum, 19 years). Sternotomy MV repairs decreased during the study while minimally invasive MV repairs increased. Robotic MV repair patients were younger, with fewer women, had better left ventricular ejection fractions, and were more likely to have myxomatous degeneration (all p<0.001). The robotic approach led to a higher MV repair rate and increased use of leaflet/chordal procedures but had longer cardiopulmonary bypass and aortic cross-clamp times (all p<0.001). The 30-day mortality for isolated MV repair was similar for all approaches (p=0.409). Fewer neurological events were observed in the videoscopic and robotic groups (p=0.013). Adjusted survival was similar for all approaches (p=0.357). Survival in patients in New York Heart Association class I to II with myxomatous degeneration or annular dilatation was similar to a matched population but was worse for patients in class III to IV or undergoing MV replacement. MV repair in patients with severe MV regurgitation should be performed before New York Heart Association class III to IV symptoms develop. Minimally invasive MV repair techniques render similar outcomes as the sternotomy approach. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs.
Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins
2015-01-01
To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate.
Manuel, Valdano; Sousa-Uva, Miguel; Morais, Humberto; Magalhães, Manuel P; Pedro, Albino; Miguel, Gade; Nunes, Maria A S; Gamboa, Sebastiana; Júnior, António P F
2015-10-01
Anomalous origin of one pulmonary artery is a rare congenital heart disease in which one pulmonary artery branch originates from the ascending aorta. To describe the experience of a cardiothoracic center in an African country to repair anomalous origin of one pulmonary artery in the context of Portugal-Angola collaboration. Between March 2011 and March 2015, four consecutive patients with anomalous origin of pulmonary artery branch underwent surgical correction. The mean age was 1.6 months. The mean weight was 4 kg. All had right pulmonary artery branch originating from the ascending aorta. All patients underwent direct implantation of right pulmonary branch to main pulmonary artery. Two patents had patent ductus arteriosus and one had atrial septal defect. Two patients had pulmonary hypertension. There was no registration of death. The mean cardiopulmonary bypass time was 75.5 ± 4.5 minutes, mean aortic cross-clamping time was 40 ± 5.6 minutes, and mean duration of the postoperative intensive care unit stay was 6.8 ± 5.7 days. At discharge, one patient had residual gradient of 25 mm Hg, the remainder had no significant gradient. The mean follow-up time was 11 months (5-28 months). One week after discharge, one patient presented operative wound dehiscence. At the last follow-up, all patients were alive, and no significant residual gradient or stenosis at site of anastomosis was observed. No reintervention was required. Anomalous origin of one pulmonary artery is a rare but potentially treatable lesion if operated early in life. Direct implantation was a good technique with good short-term results. © The Author(s) 2015.
Comparison of polyurethane with cyanoacrylate in hemostasis of vascular injury in guinea pigs
Kubrusly, Luiz Fernando; Formighieri, Marina Simões; Lago, José Vitor Martins; Graça, Yorgos Luiz Santos de Salles; Sobral, Ana Cristina Lira; Lago, Marianna Martins
2015-01-01
Objective To evaluate the behavior of castor oil-derived polyurethane as a hemostatic agent and tissue response after abdominal aortic injury and to compare it with 2-octyl-cyanoacrylate. Methods Twenty-four Guinea Pigs were randomly divided into three groups of eight animals (I, II, and III). The infrarenal abdominal aorta was dissected, clamped proximally and distally to the vascular puncture site. In group I (control), hemostasis was achieved with digital pressure; in group II (polyurethane) castor oil-derived polyurethane was applied, and in group III (cyanoacrylate), 2-octyl-cyanoacrylate was used. Group II was subdivided into IIA and IIB according to the time of preparation of the hemostatic agent. Results Mean blood loss in groups IIA, IIB and III was 0.002 grams (g), 0.008 g, and 0.170 g, with standard deviation of 0.005 g, 0.005 g, and 0.424 g, respectively (P=0.069). The drying time for cyanoacrylate averaged 81.5 seconds (s) (standard deviation: 51.5 seconds) and 126.1 s (standard deviation: 23.0 s) for polyurethane B (P=0.046). However, there was a trend (P=0.069) for cyanoacrylate to dry more slowly than polyurethane A (mean: 40.5 s; SD: 8.6 s). Furthermore, polyurethane A had a shorter drying time than polyurethane B (P=0.003), mean IIA of 40.5 s (standard deviation: 8.6 s). In group III, 100% of the animals had mild/severe fibrosis, while in group II only 12.5% showed this degree of fibrosis (P=0.001). Conclusion Polyurethane derived from castor oil showed similar hemostatic behavior to octyl-2-cyanoacrylate. There was less perivascular tissue response with polyurethane when compared with cyanoacrylate. PMID:25859876
Fresiello, Libera; Khir, Ashraf W; Di Molfetta, Arianna; Kozarski, Maciej; Ferrari, Gianfranco
2013-11-01
The aim of this study was to investigate the effects of the intra aortic balloon pump (IABP) and of aortic compliance on left ventricular performance, including the effects of baroreflex control. The study was conducted using a hybrid cardiovascular simulator, including a computational cardiovascular sub-model, a hydraulic sub-model of the descending aorta, and a baroreflex computational sub-model. A 40 cc balloon was inserted into a rubber tube component of the hydraulic sub-model. A comparative analysis was conducted for two aortic compliances (C1 = 2.4 and C2 = 1.43 cm3/mmHg, corresponding to an aortic pulse pressure of 23 mmHg and 35 mmHg, respectively), driving the balloon for different trigger timings. Under C1 conditions, the IABP induced higher effects on baroreflex activity (decrement of sympathetic efferent activity: 10% for C1 and 14.7% for C2) and ventricular performance (increment of cardiac output (CO): 3.7% for C1 and 5.2% for C2, increment of endocardial viability ratio (EVR): 24.8% for C1 and 55% for C2). The best balloon timing was different for C1 and C2: inflation trigger timing (from the dicrotic notch) -0.09 s for C1 and -0.04 s for C2, inflation duration 0.25 s for C1 and 0.2 s for C2. Early inflation ensures better EVR, CO, and an increment of the afferent nerve activity, hence causing peripheral resistance and heart rate to decrease. The best balloon timing depends on aortic compliance, thus suggesting the need for a therapy tailored to the specific conditions of individual patients.
Video assistance in mitral surgery: reaching the "Thru" port access.
Irace, Francesco G; Rose, David; D'Ascoli, Riccardo; Caldaroni, Federica; Andriani, Ines; Piscioneri, Fernando; Vitulli, Piergiusto; Piattoli, Matteo; Tritapepe, Luigi; Greco, Ernesto
2015-01-01
Minimally invasive and video assisted mitral valve surgery has been used widely since beginning of 20 th . Different reduced surgical approaches allowed replacing or repairing a mitral valve sparing sternal incision. Nevertheless the most used strategy has been in the last years the right mini thoracotomy and the extra thoracic cardiopulmonary bypass (CPB). The main goal is avoiding sternal approach for mitral valve procedures and improve postoperative course of the patients. Some postoperative complication likes blood loss, need for transfusion, prolonged intubation and infection has been reduced using this alternative technique. A special advantages has been reported in elderly or high risk patients and in redo cases. Several cardiac centres using videoscopy and a revolutionary set up for CPB management and aortic occlusion have adopted the approach. The team approach, including surgeon, anaesthesiologist, nurse, cardiologist and perfusionist, is crucial for a safe and effective realization of this surgical strategy. The proper use of catheters and Seldinger skilfulness, and the guidance of trans-esophageal echocardiography (TEE) during the procedure are two milestones of this technique. A careful and progressive learning curve is required for all the components of the team. In fact some peculiarity likes modified surgical instruments, 3D and Full HD video assisted view, percutaneous canulation for CPB and myocardial protection, etc., make this procedure challenging for all members of the operative room (OR) team. Our favourite set-up include right mini thoracotomy in the IV intercostal space, femoral vein and arterial canulation and an additional venous cannula in the superior vena cava for the drainage of the upper part of the body. Aortic occlusion is achieved usually using an endo-aortic clamp positioned by means of continuous and careful TEE guidance. A mitral valve procedure is realized by direct or video guided view; using adapted and shaft instruments or special atrial retractors all standard techniques are used in this setting. The literature reports and our published results showed the technique is safe, easy to replicate and allows an excellent rate of valve repair even in more complex patients.
Massive aggrecan and versican accumulation in thoracic aortic aneurysm and dissection
Cikach, Frank S.; Koch, Christopher D.; Mead, Timothy J.; Galatioto, Josephine; Willard, Belinda B.; Emerton, Kelly B.; Eagleton, Matthew J.; Blackstone, Eugene H.; Ramirez, Francesco; Roselli, Eric E.; Apte, Suneel S.
2018-01-01
Proteoglycan accumulation is a hallmark of medial degeneration in thoracic aortic aneurysm and dissection (TAAD). Here, we defined the aortic proteoglycanome using mass spectrometry, and based on the findings, investigated the large aggregating proteoglycans aggrecan and versican in human ascending TAAD and a mouse model of severe Marfan syndrome. The aortic proteoglycanome comprises 20 proteoglycans including aggrecan and versican. Antibodies against these proteoglycans intensely stained medial degeneration lesions in TAAD, contrasting with modest intralamellar staining in controls. Aggrecan, but not versican, was increased in longitudinal analysis of Fbn1mgR/mgR aortas. TAAD and Fbn1mgR/mgR aortas had increased aggrecan and versican mRNAs, and reduced expression of a key proteoglycanase gene, ADAMTS5, was seen in TAAD. Fbn1mgR/mgR mice with ascending aortic dissection and/or rupture had dramatically increased aggrecan staining compared with mice without these complications. Thus, aggrecan and versican accumulation in ascending TAAD occurs via increased synthesis and/or reduced proteolytic turnover, and correlates with aortic dissection/rupture in Fbn1mgR/mgR mice. Tissue swelling imposed by aggrecan and versican is proposed to be profoundly deleterious to aortic wall mechanics and smooth muscle cell homeostasis, predisposing to type-A dissections. These proteoglycans provide potential biomarkers for refined risk stratification and timing of elective aortic aneurysm repair. PMID:29515038
Massive aggrecan and versican accumulation in thoracic aortic aneurysm and dissection.
Cikach, Frank S; Koch, Christopher D; Mead, Timothy J; Galatioto, Josephine; Willard, Belinda B; Emerton, Kelly B; Eagleton, Matthew J; Blackstone, Eugene H; Ramirez, Francesco; Roselli, Eric E; Apte, Suneel S
2018-03-08
Proteoglycan accumulation is a hallmark of medial degeneration in thoracic aortic aneurysm and dissection (TAAD). Here, we defined the aortic proteoglycanome using mass spectrometry, and based on the findings, investigated the large aggregating proteoglycans aggrecan and versican in human ascending TAAD and a mouse model of severe Marfan syndrome. The aortic proteoglycanome comprises 20 proteoglycans including aggrecan and versican. Antibodies against these proteoglycans intensely stained medial degeneration lesions in TAAD, contrasting with modest intralamellar staining in controls. Aggrecan, but not versican, was increased in longitudinal analysis of Fbn1mgR/mgR aortas. TAAD and Fbn1mgR/mgR aortas had increased aggrecan and versican mRNAs, and reduced expression of a key proteoglycanase gene, ADAMTS5, was seen in TAAD. Fbn1mgR/mgR mice with ascending aortic dissection and/or rupture had dramatically increased aggrecan staining compared with mice without these complications. Thus, aggrecan and versican accumulation in ascending TAAD occurs via increased synthesis and/or reduced proteolytic turnover, and correlates with aortic dissection/rupture in Fbn1mgR/mgR mice. Tissue swelling imposed by aggrecan and versican is proposed to be profoundly deleterious to aortic wall mechanics and smooth muscle cell homeostasis, predisposing to type-A dissections. These proteoglycans provide potential biomarkers for refined risk stratification and timing of elective aortic aneurysm repair.
Yu, Shikai; Chi, Chen; Protogerou, Athanase D; Safar, Michel E; Blacher, Jacques; Argyris, Antonis A; Nasothimiou, Efthimia G; Sfikakis, Petros P; Papaioannou, Theodore G; Xu, Henry; Zhang, Yi; Xu, Yawei
2018-03-01
We aim to compare 24-hour aortic blood pressure variability (BPV) with brachial BPV in relation to carotid damage as estimated by carotid intima-media thickness (CIMT) and cross-sectional area (CCSA). Four hundred and forty five individuals received brachial and aortic 24-hour ambulatory BP monitoring with a validated device (Mobil-O-Graph). Systolic BPV was estimated by average real variability (ARV) and time-weighted standard deviation (wSD). In multiple logistic regression analysis, CIMT > 900 μm was significantly and independently associated with aortic ARV (OR = 1.38; 95% CI: 1.04-1.84), aortic wSD (OR = 1.65; 95% CI: 1.19-2.29) and brachial ARV (OR = 1.53; 95% CI: 1.07-2.18), but not with brachial wSD. CCSA > 90th percentile was significantly and independently associated with aortic ARV (OR = 1.50; 95% CI: 1.07-2.10) and wSD (OR = 1.70; 95% CI: 1.12-2.56), but not with brachial BPVs. In receiver operator characteristics curve analysis, aortic wSD identified CCSA > 90th percentile better than brachial wSD (AUC: 0.73 vs 0.68, P < .01). In conclusion, aortic 24-hour systolic BPV showed a slightly stronger association with carotid damage than brachial BPV. ©2018 Wiley Periodicals, Inc.
Type A Aortic Dissection Presenting with Inferior ST-Elevation Myocardial Infarction.
Wu, Bao-Tzung; Li, Chun-Yi; Chen, Ying-Tsung
2014-05-01
Type A aortic dissection with concurrent ST-elevation myocardial infarction (STEMI) is relatively rare. However, it can be potentially fatal and easily misdiagnosed as STEMI alone. Misdiagnosis will lead to inappropriate administration of anticoagulant and thrombolytic therapy and delayed surgical repair of the aorta. In patients with STEMI, short reperfusion time is associated with improved survival, and minimizing the door-to-balloon time is the goal of therapy worldwide. However, signs critical for differential diagnosis may be overlooked in the rush to primary percutaneous coronary intervention. When a patient is encountered who presents with chest pain and ST elevation on electrocardiogram, STEMI should not be the only diagnosis considered. By using bedside available information, detailed history taking and focused physical examination, it is possible to avoid a mistaken diagnosis. Here we report a case of Stanford type A aortic dissection with STEMI that was initially misdiagnosed as sole acute inferior wall myocardial infarction. Patient mortality may have resulted from delayed diagnosis and surgical treatment. Acute myocardial infarction; Aortic dissection.
Mortality outcomes of ruptured abdominal aortic aneurysms and rural presentation.
Munday, Emily; Walker, Stuart
2016-10-01
Centralisation of vascular surgery services has coincided with a move towards endovascular repair of ruptured abdominal aortic aneurysms with the goal to improve patient outcomes. The aim of this study was to assess the effect of rural presentation and transfer times on survival from ruptured abdominal aortic aneurysm. A retrospective review. All patients presenting with ruptured abdominal aortic aneurysm to public hospitals in Tasmania between July 2006 and April 2013. Demographic data, Glasgow aneurysm score, Hardman index, transfer times, operative technique and 30-day mortality were collected from medical records. Over the study period 127 patients presented to public hospitals in Tasmania with ruptured abdominal aortic aneurysm. A total of 27 presented to north west hospitals where no vascular surgery service is provided (NWRH), 23 to a northern hospital where an intermittent vascular surgery service is provided (LGH) and 77 to the state tertiary vascular surgery service (RHH). Of these, 4 (14.8%) died at NWRH, 6 (26.1%) died at LGH and 43 (55.8%) died at RHH without operation. Of the 35 patients transferred from NWRH and LGH to RHH, 5 died without operation. Median time from presentation to theatre at RHH if transferred from NWRH was 6.25 hours, from the LGH 4.75 hours, compared to 2.75 hours when presenting directly to RHH. Open repair was performed in 41 patients and endovascular repair in 23 patients. Overall 30-day mortality in those treated at RHH was 26.6% (39.0% for open repair, 4.3% for endovascular repair). Mortality for intended operative patients initially presenting to non-RHH hospitals was 33.3% vs. 32.3% for those initially presenting to RHH. p Value 0.93. There was no clinical or statistical disadvantage to rural presentation and transfer for patients presenting with ruptured abdominal aortic aneurysm in Tasmania. Endovascular repair has a role despite long transfer times. © The Author(s) 2015.
Yousry, Mohamed; Rickenlund, Anette; Petrini, Johan; Jenner, Jonas; Liska, Jan; Eriksson, Per; Franco-Cereceda, Anders; Eriksson, Maria J; Caidahl, Kenneth
2015-07-01
Aortic valve calcification (AVC) may predict poor outcome. Bicuspid aortic valve (BAV) leads to several haemodynamic changes accelerating the progress of aortic valve (AV) disease. To compare the diagnostic accuracy of transoesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in the assessment of aortic valve phenotype and degree of AVC, with intra-operative evaluation as a reference. We examined 169 patients (median age 65 years, 51 women) without significant coronary artery disease undergoing AV and/or aortic root surgery. TTE was performed within a week prior to surgery and TEE at the time of surgery. Compared with surgical AVC assessment, visual evaluation using a 5-grade scoring system and real-time images showed a higher correlation (TTE r = 0·83 and TEE r = 0·82) than visual (TTE r = 0·64 and TEE 0·63) or grey scale mean (GSMn) (TTE r = 0·63 and TEE r = 0·52) assessment of end-diastolic still frames. AVC assessment using real-time images showed high intraclass correlation coefficients (TTE 0·94 and TEE 0·93). With regard to BAV, TEE was superior to TTE with a higher interobserver agreement, sensitivity and specificity (0·86, 92% and 94% versus 0·57, 77% and 82%, respectively). Semi-quantitative AVC assessment of real-time cine loops from both TEE and TTE correlated well with intra-operative evaluation of AVC. Applying a predefined scoring system for AVC evaluation assures a high interobserver correlation. TEE was superior to TTE for evaluation of valve phenotype and should be considered when a diagnosis of BAV is clinically important. © 2014 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.
Aroca, Angel; Polo, Luz; Pérez-Farinós, Napoleón; González, Ana E; Bret, Montserrat; Aguilar, Elizabeth; Oliver, José M
2014-01-01
To assess the association between mortality in surgery of congenital heart disease in adults, and factors related to patients and operations. Descriptive study of operations performed by specialized surgeons in congenital heart surgery (238), adult acquired surgery (117), and specialty residents (108). The association of mortality with surgical risk and complexity, specialization of surgeon, cardiopulmonary by-pass and aortic cross clamping was assessed fitting logistic regression models. A total of 463 operations were included (442 with cardiopulmonary by-pass) in the study performed between 1991 and 2012. Median age at surgery: 34; 52.8% were women. First surgery: 295, reoperation: 168. Median score of Aristotle was 6.8, with significantly higher complexity since 2001, after restructuring the Unit. Overall hospital mortality was 3.9%. Mortality was significantly associated to number of previous surgeries (OR: 5.02; 95%CI: 1.44-17.52), operations by acquired heart disease surgeons (OR: 3.53; 95%CI: 1.14-10.98), higher Aristotle (OR: 1,64; 95%CI: 1.18-2.29), and high cardiopulmonary by-pass time (OR: 1.13; 95%CI: 1.07-1.19). Surgery of congenital heart disease in adults has been performed with low mortality. High complexity interventions, prolonged cardiopulmonary by-pass times and multiple reoperations were associated to higher mortality. Participation of cardiac surgeons specialized in congenital heart disease is associated with better outcomes. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.
An arterio-venous bridge for gradual weaning from adult veno-arterial extracorporeal life support.
Babar, Z U D; Sharma, A S; Ganushchak, Y M; Delnoij, T S R; Donker, D W; Maessen, J G; Weerwind, P W
2015-11-01
Weaning from extracorporeal life support (ELS) is particularly challenging when cardiac recovery is slow, largely incomplete and hard to predict. Therefore, we describe an individualized gradual weaning strategy using an arterio-venous (AV) bridge incorporated into the circuit to facilitate weaning. Thirty adult patients weaned from veno-arterial ELS using an AV bridge were retrospectively analyzed. Serial echocardiography and hemodynamic monitoring were used to assess cardiac recovery and load responsiveness. Upon early signs of myocardial recovery, an AV bridge with an Hoffman clamp was added to the circuit and weaning was initiated. Support flow was reduced stepwise by 10-15% every 2 to 8 hours while the circuit flow was maintained at 3.5-4.5 L/min. The AV bridge facilitated gradual weaning in all 30 patients (median age: 66 [53-71] years; 21 males) over a median period of 25 [8-32] hours, with a median support duration of 96 [31-181] hours. During weaning, the median left ventricular ejection fraction was 25% [15-32] and the median velocity time integral of the aortic valve was 16 cm [10-23]. Through the weaning period, the mean arterial blood pressure was maintained at 70 mmHg and the activated partial thromboplastin time was 60 ± 10 seconds without additional systemic heparinization. Neither macroscopic thrombus formation in the ELS circuit during and after weaning nor clinically relevant thromboembolism was observed. Incorporation of an AV bridge for weaning from veno-arterial ELS is safe and feasible to gradually wean patients with functional cardiac recovery without compromising the circuit integrity. © The Author(s) 2015.
Ishii, M; Jones, M; Shiota, T; Yamada, I; Sinclair, B; Heinrich, R S; Yoganathan, A P; Sahn, D J
1998-11-01
The purpose of our study was to determine the temporal variability of regurgitant color Doppler jet areas and the width of the color Doppler imaged vena contracta for evaluating the severity of aortic regurgitation. Twenty-nine hemodynamically different states were obtained pharmacologically in 8 sheep 20 weeks after surgery to produce aortic regurgitation. Aortic regurgitation was quantified by peak and mean regurgitant flow rates, regurgitant stroke volumes, and regurgitant fractions determined using pulmonary and aortic electromagnetic flow probes and meters balanced against each other. The regurgitant jet areas and the widths of color Doppler imaged vena contracta were measured at 4 different times during diastole to determine the temporal variability of this parameter. When measured at 4 different temporal points in diastole, a significant change was observed in the size of the color Doppler imaged regurgitant jet (percent of difference: from 31.1% to 904%; 233% +/- 245%). Simple linear regression analysis between each color jet area at 4 different periods in diastole and flow meter-based severity of the aortic regurgitation showed only weak correlation (0.23 < r < 0.49). In contrast, for most conditions only a slight change was observed in the width of the color Doppler imaged vena contracta during the diastolic regurgitant period (percent of difference, vena contracta: from 2.4% to 12.9%, 5.8% +/- 3.2%). In addition, for each period the width of the color Doppler imaged vena contracta at the 4 different time periods in diastole correlated quite strongly with volumetric measures of the severity of aortic regurgitation (0.81 < r < 0.90) and with the instantaneous flow rate for the corresponding period (0.85 < r < 0.87). Color Doppler imaged vena contracta may provide a simple, practical, and accurate method for quantifying aortic regurgitation, even when using a single frame color Doppler flow mapping image.
Feistritzer, Hans-Josef; Klug, Gert; Reinstadler, Sebastian J; Reindl, Martin; Mayr, Agnes; Schocke, Michael; Metzler, Bernhard
2016-09-01
Measurement of aortic pulse wave velocity (PWV) is the gold standard for assessment of aortic stiffness. In patients with ST-segment elevation myocardial infarction (STEMI), high aortic PWV has deleterious effects on the myocardium. In the present study, we compared a novel oscillometric device with cardiac magnetic resonance (CMR) imaging for the assessment of aortic PWV in STEMI patients. We measured aortic PWV in 60 reperfused STEMI patients using two different methods. The oscillometric method (PWVOSC) is based on mathematical transformation of brachial pressure waveforms, oscillometrically determined using a common cuff (Mobil-O-Graph, I.E.M., Stolberg, North Rhine-Westphalia, Germany). Phase-contrast CMR imaging (1.5 T scanner, Siemens, Erlangen, Bavaria, Germany) at the level of the ascending and abdominal aorta was performed to determine CMR-derived pulse wave velocity with the use of the transit time method. The mean age of the study population was 57 ± 11 years; 11 (18%) were women. Median PWVOSC was 7.4 m/s (interquartile range 6.8-8.9 m/s), and median CMR-derived pulse wave velocity was 6.3 m/s (interquartile range 5.7-8.2 m/s) (P < 0.001). A strong correlation was detected between both methods (r = 0.724, P < 0.001). Bland-Altman analysis revealed a bias of 0.62 m/s (upper and lower limit of agreement: 3.84 and -2.61 m/s). The coefficient of variation between both methods was 21%. In reperfused STEMI patients, aortic PWV assessed noninvasively by transformation of brachial pressure waveforms showed an acceptable agreement with the CMR-derived transit time method.
Alviar, Carlos L; Gutierrez, Alejandra; Cho, Leslie; Krishnaswamy, Amar; Saleh, Amr; Lincoff, Michael A; Roselli, Eric; Militello, Michael; Menon, Venu
2018-06-01
Sodium nitroprusside is the preferred agent for the treatment of high blood pressure during acute aortic syndrome if blood pressure remains elevated after heart rate control with beta-blockers. The increasing cost of sodium nitroprusside in the USA led us to assess the efficacy and safety of intravenous clevidipine, a calcium channel blocker with quick onset of action, short half-life and significantly lower costs than sodium nitroprusside, in patients presenting with acute aortic syndrome. We performed a retrospective chart review of consecutive patients admitted to the Cleveland Clinic Cardiac Intensive Care Unit from 2013-2016 with a diagnosis of acute aortic syndrome. Patients who received intravenous sodium nitroprusside were compared with those receiving intravenous clevidipine. The primary outcome was a significant difference in blood pressure at one, three and six hours. Secondary outcomes included time to achieving blood pressure target and in hospital mortality with rates of hypotension and bradycardia as safety endpoints. A total of 85 patients with suspected acute aortic pathology received clevidipine and 50 received sodium nitroprusside. Clinical and demographic characteristics were similar in both groups, except for a higher incidence of abdominal aortic aneurysm in the clevidipine group and for a trend towards higher use of labetalol in the clevidipine group. There were no significant differences in blood pressure or heart rate at one, three and six hours after starting either infusion. The rates of hypotension, bradycardia and in-hospital mortality did not differ. Time to achieve blood pressure control were also similar between groups. Intravenous clevidipine appears to be a safe and effective alternative to sodium nitroprusside for the management of high blood pressure during acute aortic dissection. In the USA, clevidipine could represent a cost effective therapy providing similar outcomes than sodium nitroprusside.
Marfan syndrome associated aortic disease in neonates and children: a clinical-morphologic review.
Ware, Adam L; Miller, Dylan V; Erickson, Lance K; Menon, Shaji C
2016-01-01
Marfan syndrome (MFS) is a multisystem connective tissue disorder that can lead to aortic dilation requiring aortic root replacement. Neonatal MFS (nMFS) is a rare and severe form of MFS compared to classic MFS (cMFS). Aortic root histology in MFS is thought to demonstrate predominantly medial degeneration (MD) of a translamellar mucoid extracellular matrix accumulation (MEMA-T) vs. the intralamellar mucoid extracellular matrix accumulation (MEMA-I) seen in other aortopathies. The objective of this study was to describe the clinical and histopathologic features of nMFS and cMFS patients undergoing aortic root replacement. Children with MFS who underwent aortic root replacement between 2000 and 2012 at a single institution were included. Medical records including clinical details, aortic dimensions (Z scores), and histology including MD type were obtained. Statistics were descriptive with univariate analysis of age at surgery and type of MD. Eleven patients, 3 (27%) with nMFS, were included. Root dilation at time of surgery was greater in nMFS compared to cMFS (Z=12.8 vs. 7.6, P=.005), and nMFS patients were younger at time of surgery (7.3 vs. 18.8 years, P=.002). Histology in the nMFS group demonstrated MEMA-I in one and no MD in two. In the cMFS group, there were three with MEMA-T, four with MEMA-I, and one with both types. In summary, nMFS has earlier root dilation often in the absence of MD. Both forms of MD were present in our cohort, and there was no correlation between age at surgery and type of MD. Copyright © 2016 Elsevier Inc. All rights reserved.
Saket, Ramin R; Razavi, Mahmood K; Padidar, Arash; Kee, Stephen T; Sze, Daniel Y; Dake, Michael D
2004-06-01
To report our experience using a commercially available catheter-based system equipped with an intravascular ultrasound (IVUS) transducer to achieve controlled true lumen re-entry in patients undergoing subintimal angioplasty for chronic total occlusions (CTO) or aortic dissections. During an 8-month period, 10 patients (6 men; mean age 73.4 years) with lower extremity (LE) ischemia from CTOs (n=7) or true lumen collapse from aortic dissections (n=3) were treated. Subintimal access and controlled re-entry of the CTOs were performed with a commercially available 6.2-F dual-lumen catheter, which contained an integrated 64-element phased-array IVUS transducer and a deployable 24-G needle through which a guidewire was passed once the target lumen was reached. The occluded segments were balloon dilated; self-expanding nitinol stents were deployed. In the aortic dissections, fenestrations were performed using the same device, with the IVUS unit acting as the guide. The fenestrations were balloon dilated and stented to support the true lumen. Time to effective re-entry ranged from 6 to 10 minutes (mean 7) in the CTOs; antegrade flow was restored in all 7 CTOs, and the patients were free of ischemic symptoms at up to 8-month follow-up. In the aortic dissection cases, the fenestrations equalized pressures between the lumens and restored flow into the compromised vessels. There were no complications related to the use of this device in any of the 10 patients. Our preliminary results demonstrate the feasibility of using this catheter-based system for subintimal recanalization with controlled re-entry in CTOs and for aortic flap fenestrations in aortic dissections. This approach can improve the technical success rate, reduce the time of the procedure, and minimize potential complications.
Effects of intra-aortic balloon counterpulsation in a model of septic shock.
Solomon, Steven B; Minneci, Peter C; Deans, Katherine J; Feng, Jing; Eichacker, Peter Q; Banks, Steven M; Danner, Robert L; Natanson, Charles; Solomon, Michael A
2009-01-01
Fluid refractory septic shock can develop into a hypodynamic cardiovascular state in both children and adults. Despite management of these patients with empirical inotropic therapy (with or without a vasodilator), mortality remains high. The effect of cardiovascular support using intra-aortic balloon counterpulsation was investigated in a hypodynamic, mechanically ventilated canine sepsis model in which cardiovascular and pulmonary support were titrated based on treatment protocols. Each week, three animals (n = 33, 10-12 kg) were administered intrabronchial Staphylococcus aureus challenge and then randomized to receive intra-aortic balloon counterpulsation for 68 hrs or no intra-aortic balloon counterpulsation (control). Bacterial doses were increased over the study (4-8 x 10(9) cfu/kg) to assess the effects of intra-aortic balloon counterpulsation during sepsis with increasing risk of death. Compared with lower bacterial doses (4-7 x 10(9) colony-forming units/kg), control animals challenged with the highest dose (8 x 10(9) colony-forming units/kg) had a greater risk of death (mortality rate 86% vs. 17%), with worse lung injury ([A - a]O2), and renal dysfunction (creatinine). These sicker animals required higher norepinephrine infusion rates to maintain blood pressure (and higher FIO2) and positive end-expiratory pressure levels to maintain oxygenation (p < or = 0.04 for all). In animals receiving the highest bacterial dose, intra-aortic balloon counterpulsation improved survival time (23.4 +/- 10 hrs longer; p = 0.003) and lowered norepinephrine requirements (0.43 +/- 0.17 microg/kg/min; p = 0.002) and systemic vascular resistance index (1.44 +/- 0.57 dynes/s/cm5/kg; p = 0.0001) compared with controls. Despite these beneficial effects, intra-aortic balloon counterpulsation was associated with an increase in blood urea nitrogen (p = 0.002) and creatinine (p = 0.12). In animals receiving lower doses of bacteria, intra-aortic balloon counterpulsation had no significant effects on survival or renal function. In a canine model of severe septic shock with a low cardiac index, intra-aortic balloon counterpulsation prolongs survival time and lowers vasopressor requirements.
Aortic valve repair with autologous pericardial patch.
Lausberg, Henning F; Aicher, Diana; Langer, Frank; Schäfers, Hans-Joachim
2006-08-01
Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair without the use of additional material. Between January 1997 and June 2005, pericardial patch plasty of the aortic valve was performed in 42 patients (PATCH). During the same period, 42 patients after AVR without the use of additional material were age matched (NO-PATCH). Mean age in both groups was 52 years with a majority of male patients (PATCH ratio, 3.7:1; NO-PATCH ratio, 5:1). Valve anatomy was similar in both groups. All patients were followed by echocardiography for a cumulative follow-up of 2341 patient months (mean 28+/-23 months). No patient died in the hospital in neither group. The average systolic gradient was 5.9+/-2.2 mmHg in PATCH and 4.8+/-2.1 mmHg in NO-PATCH; p=0.17). Freedom from aortic regurgitation > or = II degrees was 87.8% in PATCH and 95.0% in NO-PATCH after 5 years (p=0.21). Freedom from reoperation was 97.6% in PATCH and 97.4% in NO-PATCH (p=0.96). Aortic regurgitation can be treated effectively by aortic valve repair using pericardial patch plasty. The functional results are satisfactory. With the application of this technique also more complex pathologies of the aortic valve can be addressed adequately thus extending the concept of valve preservation in patients with aortic regurgitation.
Lagrangian coherent structures in the left ventricle in the presence of aortic valve regurgitation
NASA Astrophysics Data System (ADS)
di Labbio, Giuseppe; Vetel, Jerome; Kadem, Lyes
2017-11-01
Aortic valve regurgitation is a rather prevalent condition where the aortic valve improperly closes, allowing filling of the left ventricle of the heart to occur partly from backflow through the aortic valve. Although studies of intraventricular flow are rapidly gaining popularity in the fluid dynamics research community, much attention has been given to the left ventricular vortex and its potential for early detection of disease, particularly in the case of dilated cardiomyopathy. Notably, the subsequent flow in the left ventricle in the presence of aortic valve regurgitation ought to be appreciably disturbed and has yet to be described. Aortic valve regurgitation was simulated in vitro in a double-activation left heart duplicator and the ensuing flow was captured using two-dimensional time-resolved particle image velocimetry. Further insight into the regurgitant flow is obtained by computing attracting and repelling Lagrangian coherent structures. An interesting interplay between the two inflowing jets and their shear layer roll-up is observed for various grades of regurgitation. This study highlights flow features which may find use in further assessing regurgitation severity.
Mechanical deterioration underlies malignant behavior of aneurysmal human ascending aorta.
Koullias, George; Modak, Raj; Tranquilli, Maryann; Korkolis, Dimitris P; Barash, Paul; Elefteriades, John A
2005-09-01
The human ascending aorta becomes markedly prone to rupture and dissection at a diameter of 6 cm. The mechanical substrate for this malignant behavior is unknown. This investigation applied engineering analysis to human ascending aortic aneurysms and compared their structural characteristics with those of normal aortas. We measured the mechanical characteristics of the aorta by direct epiaortic echocardiography at the time of surgery in 33 patients with ascending aortic aneurysm undergoing aortic replacement and in 20 control patients with normal aortas undergoing coronary artery bypass grafting. Six parameters were measured in all patients: aortic diameter in systole and diastole, aortic wall thickness in systole and diastole, and blood pressure in systole and diastole. These were used to calculate mechanical characteristics of the aorta from standard equations. Aortic distensibility reflects the elastic qualities of the aorta. Aortic wall stress reflects the disrupting force experienced within the aortic wall. Incremental elastic modulus indicates loss of elasticity reserve. Aortic distensibility falls to extremely low levels as aortic dimension rises toward 6 cm (3.02 mm Hg(-1) for small aortas versus 1.45 mm Hg(-1) for aortas larger than 5 cm, P < .05). Aortic wall stress rises to 157.8 kPa for the aneurysmal aorta, compared with 92.5 kPa for normal aortas. For 6-cm aortas at pressures of 200 mm Hg or more, wall stress rises to 857 kPa, nearly exceeding the known maximal tensile strength of human aneurysmal aortic wall. Incremental elastic modulus deteriorates (1.93 +/- 0.88 MPa vs 1.18 +/- 0.21 MPa, P < .05) in aneurysmal aortas relative to that in normal aortas. The mechanical properties of the aneurysmal aorta deteriorate dramatically as the aorta enlarges, reaching critical levels associated with rupture by a diameter of 6 cm. This mechanical deterioration provides an explanation in engineering terms for the malignant clinical behavior (rupture and dissection) of the aorta at these dimensions. This work adds to our fundamental understanding of the biology of aortic aneurysms and promises to permit future application of engineering measurements to supplement aneurysm size in clinical decision making in aneurysmal disease.
Clamping characteristics study on different types of clamping unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiao, Zhiwei; Liu, Haichao; Xie, Pengcheng
2015-05-22
Plastic products are becoming more and more widely used in aerospace, IT, digital electronics and many other fields. With the development of technology, the requirement of product precision is getting higher and higher. However, type and working performance of clamping unit play a decisive role in product precision. Clamping characteristics of different types of clamping unit are discussed in this article, which use finite element numerical analysis method through the software ABAQUS to study the clamping uniformity, and detect the clamping force repeatability precision. The result shows that compared with toggled three-platen clamping unit, clamping characteristics of internal circulation two-platenmore » clamping unit are better, for instance, its mold cavity deformation and force that bars and mold parting surface suffered are more uniform, and its clamping uniformity and repeatability precision is also better.« less
Direct Observation of Markovian Behavior of the Mechanical Unfolding of Individual Proteins
Cao, Yi; Kuske, Rachel; Li, Hongbin
2008-01-01
Single-molecule force-clamp spectroscopy is a valuable tool to analyze unfolding kinetics of proteins. Previous force-clamp spectroscopy experiments have demonstrated that the mechanical unfolding of ubiquitin deviates from the generally assumed Markovian behavior and involves the features of glassy dynamics. Here we use single molecule force-clamp spectroscopy to study the unfolding kinetics of a computationally designed fast-folding mutant of the small protein GB1, which shares a similar β-grasp fold as ubiquitin. By treating the mechanical unfolding of polyproteins as the superposition of multiple identical Poisson processes, we developed a simple stochastic analysis approach to analyze the dwell time distribution of individual unfolding events in polyprotein unfolding trajectories. Our results unambiguously demonstrate that the mechanical unfolding of NuG2 fulfills all criteria of a memoryless Markovian process. This result, in contrast with the complex mechanical unfolding behaviors observed for ubiquitin, serves as a direct experimental demonstration of the Markovian behavior for the mechanical unfolding of a protein and reveals the complexity of the unfolding dynamics among structurally similar proteins. Furthermore, we extended our method into a robust and efficient pseudo-dwell-time analysis method, which allows one to make full use of all the unfolding events obtained in force-clamp experiments without categorizing the unfolding events. This method enabled us to measure the key parameters characterizing the mechanical unfolding energy landscape of NuG2 with improved precision. We anticipate that the methods demonstrated here will find broad applications in single-molecule force-clamp spectroscopy studies for a wide range of proteins. PMID:18375518
Early signs that predict later haemodynamically significant patent ductus arteriosus.
Engür, Defne; Deveci, Murat; Türkmen, Münevver K
2016-03-01
Our aim was to determine the optimal cut-off values, sensitivity, specificity, and diagnostic power of 12 echocardiographic parameters on the second day of life to predict subsequent ductal patency. We evaluated preterm infants, born at ⩽32 weeks of gestation, starting on their second day of life, and they were evaluated every other day until ductal closure or until there were clinical signs of re-opening. We measured transductal diameter; pulmonary arterial diastolic flow; retrograde aortic diastolic flow; pulsatility index of the left pulmonary artery and descending aorta; left atrium and ventricle/aortic root ratio; left ventricular output; left ventricular flow velocity time integral; mitral early/late diastolic flow; and superior caval vein diameter and flow as well as performed receiver operating curve analysis. Transductal diameter (>1.5 mm); pulmonary arterial diastolic flow (>25.6 cm/second); presence of retrograde aortic diastolic flow; ductal diameter by body weight (>1.07 mm/kg); left pulmonary arterial pulsatility index (⩽0.71); and left ventricle to aortic root ratio (>2.2) displayed high sensitivity and specificity (p0.9). Parameters with moderate sensitivity and specificity were as follows: left atrial to aortic root ratio; left ventricular output; left ventricular flow velocity time integral; and mitral early/late diastolic flow ratio (p0.05) had low diagnostic value. Left pulmonary arterial pulsatility index, left ventricle/aortic root ratio, and ductal diameter by body weight are useful adjuncts offering a broader outlook for predicting ductal patency.
Tanagho, Youssef S; Bhayani, Sam B; Sandhu, Gurdarshan S; Vaughn, Nicholas P; Nepple, Kenneth G; Figenshau, R Sherburne
2012-10-01
To evaluate the potential benefit of performing off-clamp robot-assisted partial nephrectomy as it relates to renal functional outcomes, while assessing the safety profile of this unconventional surgical approach. Twenty-nine patients who underwent off-clamp robot-assisted partial nephrectomy for suspected renal cell carcinoma at Washington University between March 2008 and September 2011 (group 1) were matched to 29 patients with identical nephrometry scores and comparable baseline renal function who underwent robot-assisted partial nephrectomy with hilar clamping during the same period (group 2). The matched cohorts' perioperative and renal functional outcomes were compared at a mean 9-month follow-up. Mean estimated blood loss was 146.4 mL in group 1, versus 103.9 mL in group 2 (P = .039). Mean hilar clamp time was 0 minutes in group 1 and 14.7 minutes in group 2. No perioperative complications were encountered in group 1; 1 Clavien-2 complication (3.4%) occurred in group 2 (P = 1.000). At 9-month follow-up, mean estimated glomerular filtration rate in group 1 was 79.9 versus 84.8 mL/min/1.73 m(2) preoperatively (P = .013); mean estimated glomerular filtration rate in group 2 was 74.1 versus 85.8 mL/min/1.73 m(2) preoperatively (P < .001). Hence, estimated glomerular filtration rate declined by a mean of 4.9 mL/min/1.73 m(2) in group 1 versus 11.7 mL/min/1.73 m(2) in group 2 (P = .033). Off-clamp robot-assisted partial nephrectomy is associated with a favorable morbidity profile and relatively greater renal functional preservation compared to clamped robot-assisted partial nephrectomy. Nevertheless, the benefit is small in renal functional terms and may have very limited clinical relevance. Copyright © 2012 Elsevier Inc. All rights reserved.
Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W
2012-07-01
Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing aortic valve procedures in Germany joined the registry. By now, 91 sites which perform TAVI in Germany participate and more than 15,000 datasets are already in the registry.Conclusion The implementation of new or innovative medical therapies needs supervision under the conditions of a well-structured scientific project. Up to now relevant data for implementation of TAVI and long-term results are missing. In contrast to randomized controlled trials, GARY is a prospective, controlled, 5-year observational multicenter registry, and a real world investigation with only one exclusion criterion, the absence of patients' written consent. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Novel 384-well population patch clamp electrophysiology assays for Ca2+-activated K+ channels.
John, Victoria H; Dale, Tim J; Hollands, Emma C; Chen, Mao Xiang; Partington, Leanne; Downie, David L; Meadows, Helen J; Trezise, Derek J
2007-02-01
Planar array electrophysiology techniques were applied to assays for modulators of recombinant hIK and hSK3 Ca2+-activated K+ channels. In CHO-hIK-expressing cells, under asymmetric K+ gradients, small-molecule channel activators evoked time- and voltage-independent currents characteristic of those previously described by classical patch clamp electrophysiology methods. In single-hole (cell) experiments, the large cell-to-cell heterogeneity in channel expression rendered it difficult to generate activator concentration-response curves. However, in population patch clamp mode, in which signals are averaged from up to 64 cells, well-to-well variation was substantially reduced such that concentration-response curves could be easily constructed. The absolute EC50 values and rank order of potency for a range of activators, including 1-EBIO and DC-EBIO, corresponded well with conventional patch clamp data. Activator responses of hIK and hSK3 channels could be fully and specifically blocked by the selective inhibitors TRAM-34 and apamin, with IC50 values of 0.31 microM and 3 nM, respectively. To demonstrate assay precision and robustness, a test set of 704 compounds was screened in a 384-well format of the hIK assay. All plates had Z' values greater than 0.6, and the statistical cutoff for activity was 8%. Eleven hits (1.6%) were identified from this set, in addition to the randomly spiked wells with known activators. Overall, our findings demonstrate that population patch clamp is a powerful and enabling method for screening Ca2+-activated K+ channels and provides significant advantages over single-cell electrophysiology (IonWorks(HT)) and other previously published approaches. Moreover, this work demonstrates for the 1st time the utility of population patch clamp for ion channel activator assays and for non-voltage-gated ion channels.
Sensitive and label-free detection of miRNA-145 by triplex formation.
Aviñó, Anna; Huertas, César S; Lechuga, Laura M; Eritja, Ramon
2016-01-01
The development of new strategies for detecting microRNAs (miRNAs) has become a crucial step in the diagnostic field. miRNA profiles depend greatly on the sample and the analytical platform employed, leading sometimes to contradictory results. In this work, we study the use of modified parallel tail-clamps to detect a miRNA sequence involved in tumor suppression by triplex formation. Thermal denaturing curves and circular dichroism (CD) measurements have been performed to confirm that parallel clamps carrying 8-aminoguanine form the most stable triplex structures with their target miRNA. The modified tail-clamps have been tested as bioreceptors in a surface plasmon resonance (SPR) biosensor for the detection of miRNA-145. The detection limit was improved 2.4 times demonstrating that a stable triplex structure is formed between target miRNA and 8-aminoguanine tail-clamp bioreceptor. This new approach is an essential step toward the label-free and reliable detection of miRNA signatures for diagnostic purposes.
Shutze, William; Suominem, Velipekka; Jordan, William; Cao, Piergiorgio; Oweida, Steven; Milner, Ross
2018-05-23
The Gore Global Registry for Endovascular Aortic Treatment (GREAT) was designed to evaluate real-world outcomes after treatment with Gore aortic endografts used in a real-world, global setting. We retrospectively analyzed the GREAT data to evaluate the incidence and effects of noncylindrical neck anatomy in patients undergoing endovascular aortic aneurysm repair. The present analysis included patients with data in the GREAT who had been treated with the EXCLUDER endograft from August 2010 to October 2016. A noncylindrical neck was defined when the proximal aortic landing zone diameter had changed ≥2 mm over the first 15 mm of the proximal landing zone, indicating a tapered, conical, or hourglass morphology. Cox multivariate regression analyses were performed for any reintervention (including reinterventions on aortic branch vessels), device-related reinterventions, and reintervention specifically for endoleak. Independent binary (cylindrical vs noncylindrical necks) and continuous (percentage of neck diameter change) variables were assessed. The abdominal aortic aneurysm (AAA) diameter, proximal neck length, maximal infrarenal neck angle, gender, and use of aortic extender cuffs were also assessed. Of 3077 GREAT patients with available proximal aortic landing zone diameter measurements available, 1765 were found to have cylindrical necks and 1312 had noncylindrical necks. The noncylindrical neck cohort had a significantly greater proportion of women (17.4% vs 12.6%; P < .001) and more severe infrarenal angulation (33.8° vs 28.4°; P < .001). A total 14.7% of noncylindrical neck patients and 11.2% cylindrical neck patients underwent implantation outside of the EXCLUDER instructions for use regarding the anatomic inclusion criteria (P = .004). The procedural characteristics were similar between the two cohorts; however, noncylindrical neck patients required significantly more aortic extender cuffs (P = .004). The average follow-up was 21.2 ± 17.5 months and 17.8 ± 15.8 months for the cylindrical and noncylindrical cohorts, respectively (P < .001). The Cox multivariate regression models demonstrated female gender and maximum AAA diameter were significant risk factors for subsequent reintervention (overall, device-related, and endoleak-specific). Women were 2.2 times as likely to require device-related intervention during the follow-up period compared with men (P < .001). Neck shape morphology was not a significant predictor, except for device-related intervention, for which cylindrical necks (binary definition) resulted in a slightly elevated risk (1.5 times; P = .03). Noncylindrical neck morphology was more common in women and was associated with an increased use of aortic extender cuffs but did not increase the risk of intervention. Female gender and AAA diameter were associated with an increased need for reintervention. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
The Protective Effect of Curcumin on a Spinal Cord Ischemia-Reperfusion Injury Model.
Akar, İlker; İnce, İlker; Arici, Akgül; Benli, İsmail; Aslan, Cemal; Şenol, Sefa; Demir, Osman; Altunkas, Fatih; Altındeger, Nuray; Akbas, Ali
2017-07-01
The purpose of this study is to investigate the neurological, biochemical, and histopathologic effects of both the acute and maintenance treatment of curcumin on an experimental spinal cord ischemia-reperfusion injury model in rats. The animals were randomly divided into 4 groups: (1) Sham, (2) ischemia-reperfusion (IR), (3) curcumin, and (4) solvent. Spinal cord ischemia was induced by clamping the aorta with minivascular clamps at a position just below the left renal artery and just proximal to the aortic bifurcation for 45 min. After 72 hr of reperfusion, neurological function was evaluated with a modified Tarlov score. In spinal cords, malondialdehyde (MDA), superoxide dismutase (SOD), glutathione peroxidase (GPx), and nitric oxide (NO) levels were detected biochemically. Immunohistochemical staining was performed by antibodies against interleukin-6 (IL-6) and myeloperoxidase. Histopathologic changes were examined with hematoxylin and eosin staining. Although MDA tissue levels were elevated significantly in the IR group compared with the sham group, SOD and GPx levels decreased. After the administration of curcumin, MDA levels in the spinal cord decreased, and SOD and GPx levels increased. Those changes were statistically significant. There was no significance at NO levels. Among all groups, there was no difference in IL-6 and myeloperoxidase immunostaining. Histopathological analysis showed that histopathological changes in the IR group were improved by curcumin treatment. In the curcumin group, neurological outcome scores were significantly better statistically when compared with the IR group. We believe that curcumin possesses antioxidant, antiproliferative, and anticarcinogenic properties and may be an effective drug for the prevention of spinal cord IR injury in light of the neurologic, biochemical, and histopathological data of this study and published scientific literature. Copyright © 2017 Elsevier Inc. All rights reserved.
Vitamin C prophylaxis promotes oxidative lipid damage during surgical ischemia-reperfusion.
Bailey, Damian M; Raman, Sudarsanam; McEneny, Jane; Young, Ian S; Parham, Kelly L; Hullin, David A; Davies, Bruce; McKeeman, Gareth; McCord, Joe M; Lewis, Michael H
2006-02-15
Reactive oxygen species (ROS) have been implicated in the cellular membrane damage and postoperative morbidity associated with obligatory ischemia-reperfusion (I-R) during vascular surgery. Thus, a clinical study was undertaken to evaluate the effects of ascorbate prophylaxis on ROS exchange kinetics in 22 patients scheduled for elective abdominal aortic aneurysm (AAA) or infra-inguinal bypass (IIB) repair. Patients were assigned double-blind to receive intravenous sodium ascorbate (2 g vitamin C, n=10) or placebo (0.9% saline, n=12) administered 2 h prior to surgery. Blood samples were obtained from the arterial and venous circulation proximal to the respective sites of surgical repair (local) and from an antecubital vein (peripheral) during cross-clamping (ischemia) and within 60 s of clamp release (reperfusion). Ascorbate supplementation increased the venoarterial concentration difference (v-adiff) of lipid hydroperoxides (LH), interleukin (IL)-6 and vascular endothelial growth factor (VEGF) protein during ischemia. This increased the peripheral concentration of LH, total creatine phosphokinase (CPK), and VEGF protein during reperfusion (P<0.05 vs placebo). Electron paramagnetic resonance (EPR) spectroscopy confirmed that free iron was available for oxidative catalysis in the local ischemic venous blood of supplemented patients. An increased concentration of the ascorbate radical (A.-) and alpha-phenyl-tert-butylnitrone (PBN) adducts assigned as lipid-derived alkoxyl (LO.) and alkyl (LC.) species were also detected in the peripheral blood of supplemented patients during reperfusion (P<0.05 vs ischemia). In conclusion, these findings suggest that ascorbate prophylaxis may have promoted iron-induced oxidative lipid damage via a Fenton-type reaction initiated during the ischemic phase of surgery. The subsequent release of LH into the systemic circulation may have catalyzed formation of second-generation radicals implicated in the regulation of vascular permeability and angiogenesis.
Voltage and Current Clamp Transients with Membrane Dielectric Loss
Fitzhugh, R.; Cole, K. S.
1973-01-01
Transient responses of a space-clamped squid axon membrane to step changes of voltage or current are often approximated by exponential functions of time, corresponding to a series resistance and a membrane capacity of 1.0 μF/cm2. Curtis and Cole (1938, J. Gen. Physiol. 21:757) found, however, that the membrane had a constant phase angle impedance z = z1(jωτ)-α, with a mean α = 0.85. (α = 1.0 for an ideal capacitor; α < 1.0 may represent dielectric loss.) This result is supported by more recently published experimental data. For comparison with experiments, we have computed functions expressing voltage and current transients with constant phase angle capacitance, a parallel leakage conductance, and a series resistance, at nine values of α from 0.5 to 1.0. A series in powers of tα provided a good approximation for short times; one in powers of t-α, for long times; for intermediate times, a rational approximation matching both series for a finite number of terms was used. These computations may help in determining experimental series resistances and parallel leakage conductances from membrane voltage or current clamp data. PMID:4754194
Sun, Xufang; Yang, Hua; Li, Xinyu; Wang, Yue; Zhang, Chuncheng; Song, Zhimin; Pan, Zhenxiang
2018-01-01
This study aimed to compare the effects of moderate versus deep hypothermia anesthesia for Stanford A aortic dissection surgery on brain injury. A total of 82 patients who would undergo Stanford A aortic dissection surgery were randomized into two groups: moderate hypothermia group (MH, n = 40, nasopharyngeal temperature 25 °C, and rectal temperature 28 °C) and deep hypothermia group (DH, n = 42, nasopharyngeal temperature 20 °C, and rectal temperature 25 °C). Different vascular replacement techniques including aortic root replacement, Bentall, and Wheat were used. The intraoperative and postoperative indicators of these patients were recorded. There were no differences in intraoperative and postoperative measures between MH and DH groups. The concentrations of neuron-specific enolase and S-100β increased with operation time, and were significantly lower in MH group than those in the DH group (P < 0.05). The occurrence rates of complications including chenosis, postoperative agitation, and neurological complications in MH group were significantly lower than in DH group. The recovery time, postoperative tube, and ICU intubation stay were significantly shorter in MH group than those in DH group (P < 0.05). There were no significant differences revealed in hospital stay and death rate. MH exhibited better cerebral protective effects, less complications, and shorter tube time than DH in surgery for Stanford A aortic dissection.
Kangaroo vs. porcine aortic valves: calcification potential after glutaraldehyde fixation.
Narine, K; Chéry, Cyrille C; Goetghebeur, Els; Forsyth, R; Claeys, E; Cornelissen, Maria; Moens, L; Van Nooten, G
2005-01-01
The aim of this study was to evaluate and compare the calcification potential of kangaroo and porcine aortic valves after glutaraldehyde fixation at both low (0.6%) and high (2.0%) concentrations of glutaraldehyde in the rat subcutaneous model. To our knowledge this is the first report comparing the time-related, progressive calcification of these two species in the rat subcutaneous model. Twenty-two Sprague-Dawley rats were each implanted with two aortic valve leaflets (porcine and kangaroo) after fixation in 0.6% glutaraldehyde and two aortic valve leaflets (porcine and kangaroo) after fixation in 2% glutaraldehyde respectively. Animals were sacrificed after 24 h and thereafter weekly for up to 10 weeks after implantation. Calcium content was determined using inductively coupled plasma-mass spectrometry and confirmed histologically. Mean calcium content per milligram of tissue (dry weight) treated with 0.6 and 2% glutaraldehyde was 116.2 and 110.4 microg/mg tissue for kangaroo and 95.0 and 106.8 microg/mg tissue for porcine valves. Calcium content increased significantly over time (8.8 microg/mg tissue per week) and was not significantly different between groups. Regression analysis of calcification over time showed no significant difference in calcification of valves treated with 0.6 or 2% glutaraldehyde within and between the two species. Using the subcutaneous model, we did not detect a difference in calcification potential between kangaroo and porcine aortic valves treated with either high or low concentrations of glutaraldehyde. Copyright 2005 S. Karger AG, Basel.
Farag, Emile S; van Ooij, Pim; Planken, R Nils; Dukker, Kayleigh C P; de Heer, Frederiek; Bouma, Berto J; Robbers-Visser, Danielle; Groenink, Maarten; Nederveen, Aart J; de Mol, Bas A J M; Kluin, Jolanda; Boekholdt, S Matthijs
2018-02-16
Use of 4-dimensional flow magnetic resonance imaging (4D-flow MRI) derived wall shear stress (WSS) heat maps enables identification of regions in the ascending aorta with increased WSS. These regions are subject to dysregulation of the extracellular matrix and elastic fiber degeneration, which is associated with aortic dilatation and dissection. To evaluate the effect of the presence of aortic valve stenosis and the aortic diameter on the peak WSS and surface area of increased WSS in the ascending aorta. Prospective. In all, 48 bicuspid aortic valve (BAV) patients (38.1 ± 12.4 years) and 25 age- and gender-matched healthy individuals. Time-resolved 3D phase contrast MRI with three-directional velocity encoding at 3.0T. Peak systolic velocity, WSS, and aortic diameters were assessed in the ascending aorta and 3D heat maps were used to identify regions with elevated WSS. Comparisons between groups were performed by t-tests. Correlations were investigated by univariate and multivariate regression analysis. Elevated WSS was present in 15 ± 11% (range; 1-35%) of the surface area of the ascending aorta of BAV patients with aortic valve stenosis (AS) (n = 10) and in 6 ± 8% (range; 0-31%) of the ascending aorta of BAV patients without AS (P = 0.005). The mid-ascending aortic diameter negatively correlated with the peak ascending aortic WSS (R = -0.413, P = 0.004) and the surface area of elevated WSS (R = -0.419, P = 0.003). Multivariate linear regression analysis yielded that the height of peak WSS and the amount of elevated WSS depended individually on the presence of aortic valve stenosis and the diameter of the ascending aorta. The extent of increased WSS in the ascending aorta of BAV patients depends on the presence of aortic valve stenosis and aortic dilatation and is most pronounced in the presence of AS and a nondilated ascending aorta. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 The Authors Journal of Magnetic Resonance Imaging published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Antoszewska, Magdalena
2013-05-01
Abdominal aortic aneurysms and abdominal hernias become an important health problems of our times. Abdominal aortic aneurysm and its rupture is one of the most dangerous fact in vascular surgery. There are some theories pointing to a multifactoral genesis of these kinds of diseases, all of them assume the attenuation of abdominal fascia and abdominal aortic wall. The density and continuity of these structures depend on collagen and elastic fibers structure. Reducing the strength of the fibers may be due to changes in the extracellular matrix (ECM) by the proteolytic enzymes-matrix metalloproteinases (MMPs) that degrade extracellular matrix proteins. These enzymes play an important role in the development of many disease: malignant tumors (colon, breast, lung, pancreas), cardiovascular disease (myocardial infarction, ischemia-reperfusion injury), connective tissue diseases (Ehler-Danlos Syndrome, Marfan's Syndrome), complications of diabetes (retinopathy, nephropathy). One of the most important is matrix metalloproteinase-2 (MMP-2). The aim of the study was an estimation of the MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia, and in patients with only abdominal aortic aneurysm. The study involved 88 patients aged 42 to 89 years, including 75 men and 13 women. Patients were divided into two groups: patients with abdominal aortic aneurysm and primary abdominal hernia (45 persons, representing 51.1% of all group) and patients with only abdominal aortic aneurysm (43 persons, representing 48,9% of all group). It was a statistically significant increase in MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia compared to patients with only abdominal aortic aneurysm. It was a statistically significant increase in the prevalence of POCHP in patients with only abdominal aortic aneurysm compared to patients with abdominal aortic aneurysm and primary abdominal hernia. Statistically significant higher MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia seems shows that this enzyme plays a role in the pathogenesis of primary abdominal hernias. The observed distribution of MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia may raise the conclusion that this enzyme determines the presence of multi-organ failure of the connective tissue--the patients with only abdominal aortic aneurysm had significantly lower MMP-2 blood levels.
Fisher, E A; Estioko, M R; Stern, E H; Goldman, M E
1987-07-01
Aortic root abscess occurs frequently in aortic prosthetic valve infective endocarditis. The present echocardiographic report documents a ruptured abscess that led to a direct communication between the left ventricular outflow tract and the left atrium confirmed by real-time (color flow) Doppler imaging.
Management of Recurrent Delayed Neurologic Deficit After Thoracoabdominal Aortic Operation.
Boutrous, Mina L; Afifi, Rana O; Safi, Hazim J; Estrera, Anthony L
2016-01-01
Delayed neurologic deficit (DND) is a devastating adverse event after thoracoabdominal aortic aneurysm repair. Multiple adjuncts have been devised to counteract the development of DND, most notably cerebrospinal fluid (CSF) drainage. We report a case of a 63-year-old woman in whom DND developed four times during the first 10 days after her thoracoabdominal aortic operation. This necessitated lumbar drain "weaning" to allow for a slowly rising CSF pressure and preservation of lower extremity motor function. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Type A chronic aortic dissection with obesity and preeclampsia.
Santana-Ortega, L M; Urso, S; Rodríguez-Pérez, A; Sarmiento, T; Morales, L; Hernanz, G
2017-12-01
Aortic dissection is a potentially lethal disease whose incidence in pregnant women can be up to 100 times that of the remaining adult population. In most cases, it presents as typical chest pain. We report the case of a 37yo obese woman diagnosed with chronic type A aortic dissection documented by a radiological finding 10 months after delivery. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Apple, Jeffrey; McQuade, Karen L; Hamman, Baron L; Hebeler, Robert F; Shutze, William P; Gable, Dennis R
2008-04-01
A retrospective review of 27 patients who underwent endovascular repair of thoracic aneurysms and of other thoracic aortic pathology with the thoracic aortic endograft (Gore Medical, Flagstaff, AZ) from June 2005 to July 2007 was performed. The mean follow-up period was 13.5 months (range, 2-25 months). Indications for thoracic endografting included descending thoracic aneurysms (n = 18), thoracoabdominal aneurysms (n = 3), traumatic aortic injuries (n = 3), penetrating aortic ulcers (n = 2), and contained rupture of a type B dissection (n = 1). One patient died during the procedure, for an overall mortality rate of 3.7%. The average length of stay was 8.1 days, with an average stay in the intensive care unit of 4.2 days. If patients with traumatic aortic injuries were excluded, the average overall and intensive care unit length of stay were 5.6 and 1.8 days, respectively. There was one incident of spinal cord ischemia (3.7%). There were five type I or type III endoleaks, three of which required revision (11.1%). In conclusion, thoracic endografting is a safe and viable option for the repair of descending thoracic aneurysms and other aortic pathologies. We have found it to be less invasive, even in conjunction with preoperative debranching procedures, with a shorter recovery time, decreased perioperative morbidity and blood loss, and decreased peri-operative mortality compared with standard open repair.
Sawa, Yoshiki; Takayama, Morimasa; Mitsudo, Kazuaki; Nanto, Shinsuke; Takanashi, Shuichiro; Komiya, Tatsuhiko; Kuratani, Toru; Tobaru, Tetsuya; Goto, Tsuyoshi
2015-01-01
Transcatheter aortic valve replacement (TAVR) is suggested to be less invasive and/or equally effective in comparison to conventional aortic valve replacement for high-risk symptomatic aortic stenosis patients. We herein report the initial results of a pivotal clinical trial of TAVR in Japan (the PREVAIL JAPAN). Sixty-four aortic stenosis patients (mean age 84.3 ± 6.1 years) not suitable for surgery were enrolled at three centers in Japan, with a primary composite endpoint of the 6-month post-procedure improvements in the aortic valve area and New York Heart Association (NYHA) functional classification. A transfemoral approach was used in 37 patients and a transapical approach was used in 27. The device success rate was 91.9 %. After 30 days and 6 months, the rates of mortality from any cause were 8.1 and 11.3 %, respectively. At 6 months, symptomatic stroke was found in 3.1 % of the patients, and silent infarction in 7.8 %. The aortic valve area and mean pressure gradient were significantly improved over time with both approaches (p < 0.001). At 6 months, the NYHA functional classification based on a conventional physician's assessment was improved in 87.9 % of the patients. We found results that were equivalent to those in other major TAVR trials, such as an acceptable 30-day survival (91.9 %), suggesting that balloon-expandable TAVR is effective for small Japanese AS patients classified as high-risk or inoperable.
Totally normothermic aortic arch replacement without circulatory arrest.
Touati, Gilles D; Marticho, Paul; Farag, Moataz; Carmi, Doron; Szymanski, Catherine; Barry, Misbaou; Trojette, Faouzi; Caus, Thierry
2007-08-01
Various techniques have been proposed for cerebral protection during the surgical treatment of complex aortic disease. The authors propose a revisited strategy of normothermic replacement of the aortic arch to avoid limitations and complications of profound hypothermic circulatory arrest. From April 2000 to May 2006, 19 patients with an aneurysm of the aortic arch and 10 patients with an acute (7) or a chronic (3) aortic dissection underwent a totally normothermic, complete replacement of the aortic arch using three pumps: One pump ensured antegrade cerebral perfusion, at a flow rate adapted to obtain a pressure of 70 mmHg in the right radial artery, and required a selective cannulation of the supra-aortic vessels. A second pump ensured body perfusion at a flow rate adapted to obtain a pressure of 55 mmHg in the left femoral artery and was situated between the right femoral artery and the right atrium. A special balloon aortic occlusion catheter was placed in the descending thoracic aorta. A third pump ensured intermittent normothermic myocardial perfusion via the coronary venous sinus. The arch reconstruction was performed with no time limit. There were two operative, in-hospital (6.8%) mortalities. All others patients were rapidly extubated, except one, with no neurological sequelae, and postoperative course was uneventful, without coagulopathy or hepato-renal impairment. In the light of these results, a normothermic procedure is possible for arch surgery and may ensure a more physiological autoregulation of cerebral blood flow while maintaining body perfusion without high vascular resistances.
``Smart'' baroreception along the aortic arch, with reference to essential hypertension
NASA Astrophysics Data System (ADS)
Kember, G. C.; Zamir, M.; Armour, J. A.
2004-11-01
Beat-to-beat regulation of heart rate is dependent upon sensing of local stretching or local “disortion” by aortic baroreceptors. Distortions of the aortic wall are due mainly to left ventricular output and to reflected waves arising from the arterial tree. Distortions are generally believed to be useful in cardiac control since stretch receptors or aortic baroreceptors embedded in the adventitia of the aortic wall, transduce the distortions to cardiovascular neural reflex pathways responsible for beat-to-beat regulation of heart rate. Aortic neuroanatomy studies have also found a continuous strip of mechanosensory neurites spread along the aortic inner arch. Although their purpose is now unknown, such a combined sensing capacity would allow measurement of the space and time dependence of inner arch wall distortions due, among other things, to traveling waves associated with pulsatile flow in an elastic tube. We call this sensing capability-“smart baroreception.” In this paper we use an arterial tree model to show that the cumulative effects of wave reflections, from many sites far downstream, have a surprisingly pronounced effect on the pressure distribution in the root segment of the tree. By this mechanism global hemodynamics can be focused by wave reflections back to the aortic arch, where they can rapidly impact cardiac control via smart baroreception. Such sensing is likely important to maintain efficient heart function. However, alterations in the arterial tree due to aging and other natural processes can lead in such a system to altered cardiac control and essential hypertension.
Apple, Jeffrey; McQuade, Karen L.; Hamman, Baron L.; Hebeler, Robert F.; Shutze, William P.
2008-01-01
A retrospective review of 27 patients who underwent endovascular repair of thoracic aneurysms and of other thoracic aortic pathology with the thoracic aortic endograft (Gore Medical, Flagstaff, AZ) from June 2005 to July 2007 was performed. The mean follow-up period was 13.5 months (range, 2–25 months). Indications for thoracic endografting included descending thoracic aneurysms (n = 18), thoracoabdominal aneurysms (n = 3), traumatic aortic injuries (n = 3), penetrating aortic ulcers (n = 2), and contained rupture of a type B dissection (n = 1). One patient died during the procedure, for an overall mortality rate of 3.7%. The average length of stay was 8.1 days, with an average stay in the intensive care unit of 4.2 days. If patients with traumatic aortic injuries were excluded, the average overall and intensive care unit length of stay were 5.6 and 1.8 days, respectively. There was one incident of spinal cord ischemia (3.7%). There were five type I or type III endoleaks, three of which required revision (11.1%). In conclusion, thoracic endografting is a safe and viable option for the repair of descending thoracic aneurysms and other aortic pathologies. We have found it to be less invasive, even in conjunction with preoperative debranching procedures, with a shorter recovery time, decreased perioperative morbidity and blood loss, and decreased peri-operative mortality compared with standard open repair. PMID:18382748
Abdominal aortic aneurysm neck remodeling after open aneurysm repair.
Falkensammer, Juergen; Oldenburg, W Andrew; Biebl, Matthias; Hugl, Beate; Hakaim, Albert G; Crook, Julia E; Berland, Todd L; Paz-Fumagalli, Ricardo
2007-05-01
Proximal endovascular aortic graft fixation and maintenance of hemostatic seal depends on the long-term stability of the aortic neck. Previous investigations of aortic neck dilation mostly focused on the infrarenal aortic diameter. Fenestrated and branched stent grafts facilitate suprarenal graft fixation and may thereby improve the long-term integrity of the aortic attachment site. For these devices, the natural history of the suprarenal aortic segment is also of interest. We investigated the natural history of the supra- and infrarenal aortic segment after open abdominal aortic aneurysm (AAA) repair. For this retrospective analysis, we reviewed the preoperative and the initial postoperative as well as the most recent CT series that were obtained from 52 patients undergoing conventional repair of an infrarenal abdominal aortic aneurysm between January 1998 and December 2002. Measurements were performed using electronic calipers on a "split screen", allowing direct comparison of subsequent CT series at corresponding levels along the vessel. Main outcome measures were changes in postoperative measures of the supra- and infrarenal aortic diameters. The first postoperative exam was at a mean (+/-SD) of 7.0 +/- 3.5 months, and the final exams were at 44.4 +/- 21 months. Over this time period, the estimated rate of change in suprarenal diameter was 0.18 mm/ y with 95% confidence interval (CI) from 0.08 to 0.27. The estimated rate of change for the infrarenal diameter was 0.16 (95% CI: 0.05 to 0.27). A clinically relevant diameter increase of >or=3 mm was observed in seven patients (13%). There was evidence of larger diameter increases associated with larger AAA diameters (P = .003 and <.001 for suprarenal and infrarenal diameters), an inverted funnel shape (P = .002 and <.001), and marginal evidence of association with a history of inguinal hernia (P = .043 and .066). Although there is statistically significant evidence of increases in the supra- and infrarenal aortic diameters after conventional AAA repair, mean annual increases tended to be small and clinically relevant increases of 3 mm or more were observed in only a small proportion of cases.
2013-05-14
enzymes . At sufficiently high doses of glutamate, this process culminates in excitogenic cell death [1]. Treatments to mitigate neuronal damage during...To evaluate the potential for therapeutic screening, we assessed the effect of several small molecule antagonists on excitotoxicity in a moderate...C. Current clamp recordings showing repeated overshooting action potentials are evoked by injection of a 75 pA current. D. Voltage-clamp recordings
Tanaka, Akiko; Estrera, Anthony L
2018-01-01
Cerebral complication is a major concern after aortic arch surgery, which may lead to death. Thus, cerebral protection strategy plays the key role to obtain respectable results in aortic arch repair. Deep hypothermic circulatory arrest was introduced in 1970s to decrease the ischemic insults to the brain. However, safe duration of circulatory arrest time was limited to 30 minutes. The 1990s was the decade of evolution for cerebral protection, in which two adjuncts for deep hypothermic circulatory arrest were introduced: retrograde and antegrade cerebral perfusion (ACP) techniques. These two cerebral perfusion techniques significantly decreased incidence of postoperative neurological dysfunction and mortality after aortic arch surgery. Although there are no large prospective studies that demonstrate which perfusion technique provide better outcomes, multiple retrospective studies implicate that ACP may decrease cerebral complications compared to retrograde cerebral perfusion (RCP) when a long circulatory arrest time is required during aortic arch reconstructions. To date, many surgeons favor ACP over RCP during a complex aortic arch repair, such as total arch replacement and hybrid arch replacement. However, the question is whether the use of ACP is necessary during a short, limited circulatory arrest time, such as hemiarch replacement? There is a paucity of data that proves the advantages of a complex ACP over a simple RCP for a short circulatory arrest time. RCP with deep hypothermic circulatory arrest is the simple, efficient cerebral protection technique with minimal interference to the surgical field-and it potentially allows to flush atheromatous debris out from the arch vessels. Thus, it is the preferred adjunct to deep hypothermic circulatory arrest during hemiarch replacement in our institution.
Tanaka, Akiko
2018-01-01
Cerebral complication is a major concern after aortic arch surgery, which may lead to death. Thus, cerebral protection strategy plays the key role to obtain respectable results in aortic arch repair. Deep hypothermic circulatory arrest was introduced in 1970s to decrease the ischemic insults to the brain. However, safe duration of circulatory arrest time was limited to 30 minutes. The 1990s was the decade of evolution for cerebral protection, in which two adjuncts for deep hypothermic circulatory arrest were introduced: retrograde and antegrade cerebral perfusion (ACP) techniques. These two cerebral perfusion techniques significantly decreased incidence of postoperative neurological dysfunction and mortality after aortic arch surgery. Although there are no large prospective studies that demonstrate which perfusion technique provide better outcomes, multiple retrospective studies implicate that ACP may decrease cerebral complications compared to retrograde cerebral perfusion (RCP) when a long circulatory arrest time is required during aortic arch reconstructions. To date, many surgeons favor ACP over RCP during a complex aortic arch repair, such as total arch replacement and hybrid arch replacement. However, the question is whether the use of ACP is necessary during a short, limited circulatory arrest time, such as hemiarch replacement? There is a paucity of data that proves the advantages of a complex ACP over a simple RCP for a short circulatory arrest time. RCP with deep hypothermic circulatory arrest is the simple, efficient cerebral protection technique with minimal interference to the surgical field—and it potentially allows to flush atheromatous debris out from the arch vessels. Thus, it is the preferred adjunct to deep hypothermic circulatory arrest during hemiarch replacement in our institution. PMID:29682460
Anatomic partial nephrectomy: technique evolution.
Azhar, Raed A; Metcalfe, Charles; Gill, Inderbir S
2015-03-01
Partial nephrectomy provides equivalent long-term oncologic and superior functional outcomes as radical nephrectomy for T1a renal masses. Herein, we review the various vascular clamping techniques employed during minimally invasive partial nephrectomy, describe the evolution of our partial nephrectomy technique and provide an update on contemporary thinking about the impact of ischemia on renal function. Recently, partial nephrectomy surgical technique has shifted away from main artery clamping and towards minimizing/eliminating global renal ischemia during partial nephrectomy. Supported by high-fidelity three-dimensional imaging, novel anatomic-based partial nephrectomy techniques have recently been developed, wherein partial nephrectomy can now be performed with segmental, minimal or zero global ischemia to the renal remnant. Sequential innovations have included early unclamping, segmental clamping, super-selective clamping and now culminating in anatomic zero-ischemia surgery. By eliminating 'under-the-gun' time pressure of ischemia for the surgeon, these techniques allow an unhurried, tightly contoured tumour excision with point-specific sutured haemostasis. Recent data indicate that zero-ischemia partial nephrectomy may provide better functional outcomes by minimizing/eliminating global ischemia and preserving greater vascularized kidney volume. Contemporary partial nephrectomy includes a spectrum of surgical techniques ranging from conventional-clamped to novel zero-ischemia approaches. Technique selection should be tailored to each individual case on the basis of tumour characteristics, surgical feasibility, surgeon experience, patient demographics and baseline renal function.
Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.
Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy
2016-03-01
SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.
Percutaneous Dual-valve Intervention in a High-risk Patient with Severe Aortic and Mitral Stenosis
Mrevlje, Blaz; Aboukura, Mohamad; Nienaber, Christoph A.
2016-01-01
Aortic stenosis is the most frequent and mitral stenosis is the least frequent native single-sided valve disease in Europe. Patients with the combination of severe symptomatic degenerative aortic and mitral stenosis are very rare. Guidelines for the treatment of heart valve diseases are clear for single-valve situations. However, there is no common agreement or recommendation for the best treatment strategy in patients with multiple valve disease and severe concomitant comorbidities. A 76-year-old female patient with the combination of severe degenerative symptomatic aortic and mitral stenosis and several comorbidities including severe obesity, who was found unsuitable surgical candidate by the heart team and unsuitable for two-time general anesthesia in the case of two-step single-valve percutaneous approach by anesthesiologists, underwent successful percutaneous dual-valve single-intervention (transcatheter aortic valve implantation and percutaneous mitral balloon commissurotomy). Percutaneous dual-valve single-intervention is feasible in selected symptomatic high-risk patients. PMID:27867460
Next-Generation Transcatheter Heart Valves: Current Trials in Europe and the USA
Werner, Nikos; Nickenig, Georg
2012-01-01
Transcatheter aortic valve implantation (TAVI) has proven to be a viable alternative for patients with symptomatic severe aortic stenosis who are at high risk for surgical aortic valve replacement. At the same time, there is increasing evidence that moderate-to-severe periprosthetic aortic regurgitation after TAVI is associated with dramatically increased mortality and morbidity. The issue of proper positioning of the valve, including the ability to reposition and recapture the device, must be dealt with before the use of TAVI can be extended to younger, healthier patients. The next generation of transcatheter heart valves will most likely address repositionability to facilitate accurate placement with additional features that minimize paravalvular leakage. Upcoming devices promise to improve outcomes and usability of current TAVI systems. PMID:22891121
Siddiqi, Hasan K; Luminais, Steven N; Montgomery, Dan; Bossone, Eduardo; Dietz, Harry; Evangelista, Arturo; Isselbacher, Eric; LeMaire, Scott; Manfredini, Roberto; Milewicz, Dianna; Nienaber, Christoph A; Roman, Mary; Sechtem, Udo; Silberbach, Michael; Eagle, Kim A; Pyeritz, Reed E
2017-03-01
Marfan syndrome (MFS) is an autosomal dominant connective tissue disease associated with acute aortic dissection (AAD). We used 2 large registries that include patients with MFS to investigate possible trends in the chronobiology of AAD in MFS. We queried the International Registry of Acute Aortic Dissection (IRAD) and the Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC) registry to extract data on all patients with MFS who had suffered an AAD. The group included 257 patients with MFS who suffered an AAD from 1980 to 2012. The chi-square tests were used for statistical testing. Mean subject age at time of AAD was 38 years, and 61% of subjects were men. AAD was more likely in the winter/spring season (November to April) than the other half of the year (57% vs 43%, p = 0.05). Dissections were significantly more likely to occur during the daytime hours, with 65% of dissections occurring from 6 a.m. to 6 p.m. (p = 0.001). Men were more likely to dissect during the daytime hours (6 a.m. to 6 p.m.) than women (74% vs 51%, p = 0.01). These insights offer a glimpse of the times of greatest vulnerability for patients with MFS who suffer from this catastrophic event. In conclusion, the chronobiology of AAD in MFS reflects that of AAD in the general population. Copyright © 2016 Elsevier Inc. All rights reserved.
Influences on Early and Medium-Term Survival Following Surgical Repair of the Aortic Arch
Bashir, Mohamad; Field, Mark; Shaw, Matthew; Fok, Matthew; Harrington, Deborah; Kuduvalli, Manoj; Oo, Aung
2014-01-01
Objectives: It is now well established by many groups that surgery on the aortic arch may be achieved with consistently low morbidity and mortality along with relatively good survival compared to estimated natural history for a number of aortic arch pathologies. The objectives of this study were to: 1) report, compare, and analyze our morbidity and mortality outcomes for hemiarch and total aortic arch surgery; 2) examine the survival benefit of hemiarch and total aortic arch surgery compared to age- and sex-matched controls; and 3) define factors which influence survival in these two groups and, in particular, identify those that are modifiable and potentially actionable. Methods: Outcomes from patients undergoing surgical resection of both hemiarch and total aortic arch at the Liverpool Heart and Chest Hospital between June 1999 and December 2012 were examined in a retrospective analysis of data collected for The Society for Cardiothoracic Surgeons (UK). Results: Over the period studied, a total of 1240 patients underwent aortic surgery, from which 287 were identified as having undergone hemi to total aortic arch surgery under deep or moderate hypothermic circulatory arrest. Twenty three percent of patients' surgeries were nonelective. The median age at the time of patients undergoing elective hemiarch was 64.3 years and total arch was 65.3 years (P = 0.25), with 40.1% being female in the entire group. A total of 140 patients underwent elective hemiarch replacement, while 81 underwent elective total arch replacement. Etiology of the aortic pathology was degenerative in 51.2% of the two groups, with 87.1% requiring aortic valve repair in the elective hemiarch group and 64.2% in the elective total arch group (P < 0.001). Elective in-hospital mortality was 2.1% in the hemiarch group and 6.2% (P = 0.15) in the total arch group with corresponding rates of stroke (2.9% versus 4.9%, P = 0.47), renal failure (4.3% versus 6.2%, P = 0.54), reexploration for bleeding (4.3% versus 4.9%, P > 0.99), and prolonged ventilation (8.6% versus 16.1%, P = 0.09). Overall mortality was 20.9% at 5 years, while it was 15.7% in the elective hemiarch and 25.9% in the total arch group (P = 0.065). Process control charts demonstrated stability of annualized mortality outcomes over the study period. Survival curve was flat and parallel compared to age- and sex-matched controls beyond 2 years. Multivariate analysis demonstrated the following independent factors associated with survival: renal dysfunction [hazard ratio (HR) = 3.11; 95% confidence interval (CI) = 1.44-6.73], New York Heart Association (NYHA) class ≥ III (HR = 2.25; 95% CI = 1.38-3.67), circulatory arrest time > 100 minutes (HR = 2.92; 95% CI = 1.57-5.43), peripheral vascular disease (HR = 2.44; 95% CI = 1.25-4.74), and concomitant coronary artery bypass graft operation (HR = 2.14; 95% CI = 1.20-3.80). Conclusions: Morbidity, mortality, and medium-term survival were not statistically different for patients undergoing elective hemi-aortic arch and total aortic arch surgery. The survival curve in this group of patients is flat and parallel to sex- and age-matched controls beyond 2 years. Multivariate analysis identified independent influences on survival as renal dysfunction, NYHA class ≥ III, circulatory arrest time (> 100 min), peripheral vascular disease, and concomitant coronary artery bypass grafting. Focus on preoperative optimization of some of these variables may positively influence long-term survival. PMID:26798716
Relationship Between Proximal Aorta Morphology and Progression Rate of Aortic Stenosis.
Capoulade, Romain; Teoh, Jonathan G; Bartko, Philipp E; Teo, Eliza; Scholtz, Jan-Erik; Tastet, Lionel; Shen, Mylene; Mihos, Christos G; Park, Yong H; Garcia, Julio; Larose, Eric; Isselbacher, Eric M; Sundt, Thoralf M; MacGillivray, Thomas E; Melnitchouk, Serguei; Ghoshhajra, Brian B; Pibarot, Philippe; Hung, Judy
2018-05-01
The aim of this study was to examine the association between abnormal morphology of the proximal aorta and aortic stenosis (AS) progression rate. The main hypothesis was that morphologic changes of the proximal aorta, such as effacement of the sinotubular junction (STJ), result in increased biomechanical stresses and contribute to calcification and progression of AS. Between 2010 and 2012, 426 patients with mild to moderate AS were included in this study. Proximal aortic dimensions were measured at three different levels (i.e., sinus of Valsalva, STJ, and ascending aorta), and sinuses of Valsalva/STJ and ascending aorta/STJ ratios were used to determine degree of aortic deformity. AS progression rate was assessed by annualized increase in mean gradient (median follow-up time, 3.1 years; interquartile range, 2.6-3.9 years). The degree of aortic flow turbulence was examined in 18 matched patients with and without STJ effacement using cardiac magnetic resonance phase-contrast imaging. Patients' mean age was 71 ± 13 years, and 64% were men. Patients with low ratios had greater AS progression (P < .05). After comprehensive adjustment, sinuses of Valsalva/STJ (P = .025) and ascending aorta/STJ (P = .027) ratios were independently associated with greater AS progression rate. Compared with patients without STJ effacement, those with effacement of the STJ had higher degrees of aortic flow turbulence (24.4% vs 17.2%, P = .038). Effacement of the STJ is independently associated with greater AS progression, regardless of arterial hemodynamics, aortic valve phenotype, or baseline AS severity. Patients with abnormal proximal aortic geometry had disturbed aortic flow patterns. These findings suggest an interrelation between proximal aorta morphology and stenosis progression. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Satheesan, S; Figarola, J L; Dabbs, T; Rahbar, S; Ermel, R
2014-06-01
We determined the effects of treatment with LR-90, an inhibitor of advanced glycation end products, on the mechanical properties of the arterial system in streptozotocin (STZ)-induced diabetic Sprague Dawley rats, using aortic impedance analysis, and further investigated the effects of LR-90 on the progression of aortic pathology. STZ-induced diabetic rats were treated with or without LR-90 (50 mg L(-1) in drinking water) for 8 weeks and compared with control groups. Arterial BP measurements, various metabolic parameters, aortic histopathology, collagen cross-linking, AGE accumulation, and RAGE protein expression in aortic tissue were determined. Pulsatile parameters were evaluated using a standard Fourier series expansion technique and impulse response function of the filtered aortic input impedance spectra. LR-90 reduced glycated haemoglobin and triglycerides levels, although it had no effect on the glycaemic status. LR-90 did not affect arterial BP, but prevented the diabetes-induced increase in peripheral resistance and variations in aortic distensibility, as it reduced aortic characteristic impedance by 21%. LR-90 also prevented the elevation in wave reflection factor, as indicated by a 22.5% reduction and an associated increase of 23.5% in wave transit time, suggesting it prevents the augmentation of the systolic load of the left ventricle. Moreover, LR-90 inhibited collagen cross-linking and the accumulation of AGE and RAGE in the vasculature of diabetic rats. Treatment with LR-90 may impart significant protection against diabetes-induced aortic stiffening and cardiac hypertrophy and provides an additional therapeutic option for treatment of AGE associated diabetic complications. © 2014 The British Pharmacological Society.
Chiu, Hsin-Hui; Wu, Mei-Hwan; Wang, Jou-Kou; Lu, Chun-Wei; Chiu, Shuenn-Nan; Chen, Chun-An; Lin, Ming-Tai; Hu, Fu-Chang
2013-03-01
To assess the tolerability and efficacy of the investigational use of the angiotensin II receptor blocker losartan added to β-blockade (BB) to prevent progressive aortic root dilation in patients with Marfan syndrome (MFS). Between May 1, 2007, and September 31, 2011, 28 patients with MFS (11 males [39%]; mean ± SD age, 13.1±6.3 years) with recognized aortic root dilation (z score >2.0) and receiving BB (atenolol or propranolol) treatment were enrolled. They were randomized to receive BB (BB: 13 patients) or β-blockade and losartan (BB-L: 15 patients) for 35 months. In the BB-L group, aortic root dilation was reduced with treatment, and the annual dilation rate of the aortic root was significantly lower than that of the BB group (0.10 mm/yr vs 0.89 mm/yr; P=.02). The absolute aortic diameters at the sinus of Valsalva, annulus, and sinotubular junction showed similar trends, with a reduced rate of dilation in the BB-L group (P=.02, P=.03, and P=.03, respectively). Five patients (33%) treated with BB-L were noted to have a reduced aortic root diameter. However, the differences between the groups regarding changes in aortic stiffness and cross-sectional compliance were not statistically significant. This randomized, open-label, active controlled trial mostly based on a pediatric population demonstrated for the first time that losartan add-on BB therapy is safe and provides more effective protection to slow the progression of aortic root dilation than does BB treatment alone in patients with MFS. clinicaltrials.gov Identifier: NCT00651235. Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Kingsley, J Derek; Tai, Yu Lun; Mayo, Xian; Glasgow, Alaina; Marshall, Erica
2017-09-01
We sought to determine the sex-specific effects of an acute bout of free-weight resistance exercise (RE) on pulse wave reflection (aortic blood pressures, augmentation index (AIx), AIx at 75 bpm (AIx@75), augmentation pressure (AP), time of the reflected wave (Tr), subendocardial viability ratio (SEVR)), and aortic arterial stiffness in resistance-trained individuals. Resistance-trained men (n = 14) and women (n = 12) volunteered to participate in the study. Measurements were taken in the supine position at rest, and 10 minutes after 3 sets of 10 repetitions at 75% 1-repetition maximum on the squat, bench press, and deadlift. A 2 × 2 × 2 ANOVA was used to analyse the effects of sex (men, women) across condition (RE, control) and time (rest, recovery). There were no differences between sexes across conditions and time. There was no effect of the RE on brachial or aortic blood pressures. There were significant condition × time interactions for AIx (rest: 12.1 ± 7.9%; recovery: 19.9 ± 10.5%, p = .003), AIx@75 (rest: 5.3 ± 7.9%; recovery: 24.5 ± 14.3%, p = .0001), AP (rest: 4.9 ± 2.8 mmHg; recovery: 8.3 ± 6.0 mmHg, p = .004), and aortic arterial stiffness (rest: 5.3 ± 0.6 ms; recovery: 5.9 ± 0.7 ms, p = .02) with significant increases during recovery from the acute RE. There was also a significant condition × time for time of the reflected wave (rest: 150 ± 7 ms; recovery: 147 ± 9 ms, p = .02) and SEVR (rest: 147 ± 17%; recovery: 83 ± 24%, p = .0001) such that they were reduced during recovery from the acute RE compared to the control. These data suggest that an acute bout of RE increases AIx, AIx@75, and aortic arterial stiffness similarly between men and women without significantly altering aortic blood pressures.
Current outcomes of off-pump coronary artery bypass grafting: evidence from real world practice
2016-01-01
Coronary artery bypass grafting (CABG) can be performed conventionally using cardiopulmonary bypass (CPB) and aortic clamping or on a beating heart (BH) without the use of CPB, the so-called off-pump CABG. Some surgeons, who are proponents of off-pump CABG, preferentially use this technique for the majority of operations, whereas others use it only in certain situations which warrant avoidance of CPB. Ever since the conception of off-pump CABG, the never-ending debate about which technique of CABG is safe and efficacious continues to date. Several randomized controlled trials (RCTs) have been conducted that have either favored on-pump CABG or have failed to show a significant difference in outcomes between the two techniques. However, these RCTs have been fraught with claims that they do not represent the majority of patients undergoing CABG in real world practice. Therefore, assessment of the benefits and drawbacks of each technique through observational and registry studies would be more representative of patients encountered in daily practice. The present review examines various retrospective studies and meta-analyses of observational studies that compare the early and long-term outcomes of off- and on-pump CABG, which assesses their safety and efficacy. Additionally, their outcomes in older patients, females, and those with diabetes mellitus, renal dysfunction, presence of ascending aortic disease, and/or acute coronary syndrome (ACS) have also been discussed separately. The general consensus is that early results of off-pump CABG are comparable to or in some cases better than on-pump CABG. However, on-pump CABG provides a survival benefit in the long term according to a majority of publications in literature. PMID:27942395
Markandeya, Yogananda S.; Phelan, Laura J.; Woon, Marites T.; Keefe, Alexis M.; Reynolds, Courtney R.; August, Benjamin K.; Hacker, Timothy A.; Roth, David M.; Patel, Hemal H.; Balijepalli, Ravi C.
2015-01-01
Pathological cardiac hypertrophy is characterized by subcellular remodeling of the ventricular myocyte with a reduction in the scaffolding protein caveolin-3 (Cav-3), altered Ca2+ cycling, increased protein kinase C expression, and hyperactivation of calcineurin/nuclear factor of activated T cell (NFAT) signaling. However, the precise role of Cav-3 in the regulation of local Ca2+ signaling in pathological cardiac hypertrophy is unclear. We used cardiac-specific Cav-3-overexpressing mice and in vivo and in vitro cardiac hypertrophy models to determine the essential requirement for Cav-3 expression in protection against pharmacologically and pressure overload-induced cardiac hypertrophy. Transverse aortic constriction and angiotensin-II (Ang-II) infusion in wild type (WT) mice resulted in cardiac hypertrophy characterized by significant reduction in fractional shortening, ejection fraction, and a reduced expression of Cav-3. In addition, association of PKCα and angiotensin-II receptor, type 1, with Cav-3 was disrupted in the hypertrophic ventricular myocytes. Whole cell patch clamp analysis demonstrated increased expression of T-type Ca2+ current (ICa, T) in hypertrophic ventricular myocytes. In contrast, the Cav-3-overexpressing mice demonstrated protection from transverse aortic constriction or Ang-II-induced pathological hypertrophy with inhibition of ICa, T and intact Cav-3-associated macromolecular signaling complexes. siRNA-mediated knockdown of Cav-3 in the neonatal cardiomyocytes resulted in enhanced Ang-II stimulation of ICa, T mediated by PKCα, which caused nuclear translocation of NFAT. Overexpression of Cav-3 in neonatal myocytes prevented a PKCα-mediated increase in ICa, T and nuclear translocation of NFAT. In conclusion, we show that stable Cav-3 expression is essential for protecting the signaling mechanisms in pharmacologically and pressure overload-induced cardiac hypertrophy. PMID:26170457
QPatch: the missing link between HTS and ion channel drug discovery.
Mathes, Chris; Friis, Søren; Finley, Michael; Liu, Yi
2009-01-01
The conventional patch clamp has long been considered the best approach for studying ion channel function and pharmacology. However, its low throughput has been a major hurdle to overcome for ion channel drug discovery. The recent emergence of higher throughput, automated patch clamp technology begins to break this bottleneck by providing medicinal chemists with high-quality, information-rich data in a more timely fashion. As such, these technologies have the potential to bridge a critical missing link between high-throughput primary screening and meaningful ion channel drug discovery programs. One of these technologies, the QPatch automated patch clamp system developed by Sophion Bioscience, records whole-cell ion channel currents from 16 or 48 individual cells in a parallel fashion. Here, we review the general applicability of the QPatch to studying a wide variety of ion channel types (voltage-/ligand-gated cationic/anionic channels) in various expression systems. The success rate of gigaseals, formation of the whole-cell configuration and usable cells ranged from 40-80%, depending on a number of factors including the cell line used, ion channel expressed, assay development or optimization time and expression level in these studies. We present detailed analyses of the QPatch features and results in case studies in which secondary screening assays were successfully developed for a voltage-gated calcium channel and a ligand-gated TRP channel. The increase in throughput compared to conventional patch clamp with the same cells was approximately 10-fold. We conclude that the QPatch, combining high data quality and speed with user friendliness and suitability for a wide array of ion channels, resides on the cutting edge of automated patch clamp technology and plays a pivotal role in expediting ion channel drug discovery.
Zhu, Jundong; Jiang, Fan; Li, Pu; Shao, Pengfei; Liang, Chao; Xu, Aiming; Miao, Chenkui; Qin, Chao; Wang, Zengjun; Yin, Changjun
2017-09-11
To explore the feasibility and safety of retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping for the patients with multiple renal tumor of who have solitary kidney or contralateral kidney insufficiency. Nine patients who have undergone retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping between October 2010 and January 2017 were retrospectively analyzed. Clinical materials and parameters during and after the operation were summarized. Nineteen tumors were resected in nine patients and the operations were all successful. The operation time ranged from 100 to 180 min (125 min); clamping time of segmental renal artery was 10 ~ 30 min (23 min); the amount of blood loss during the operation was 120 ~ 330 ml (190 ml); hospital stay after the operation is 3 ~ 6d (5d). There was no complication during the perioperative period, and the pathology diagnosis after the surgery showed that there were 13 renal clear cell carcinomas, two papillary carcinoma and four perivascular epithelioid cell tumors with negative margins from the 19 tumors. All patients were followed up for 3 ~ 60 months, and no local recurrence or metastasis was detected. At 3-month post-operation follow-up, the mean serum creatinine was 148.6 ± 28.1 μmol/L (p = 0.107), an increase of 3.0 μmol/L from preoperative baseline. For the patients with multiple renal tumors and solitary kidney or contralateral kidney insufficiency, retroperitoneal laparoscopic partial nephrectomy with sequential segmental renal artery clamping was feasible and safe, which minimized the warm ischemia injury to the kidney and preserved the renal function effectively.
Kwag, Jeehyun; Paulsen, Ole
2009-08-26
Precisely controlled spike times relative to theta-frequency network oscillations play an important role in hippocampal memory processing. Here we study how inhibitory synaptic input during theta oscillation contributes to the control of spike timing. Using whole-cell patch-clamp recordings from CA1 pyramidal cells in vitro with dynamic clamp to simulate theta-frequency oscillation (5 Hz), we show that gamma-aminobutyric acid-A (GABA(A)) receptor-mediated inhibitory postsynaptic potentials (IPSPs) can not only delay but also advance the postsynaptic spike depending on the timing of the inhibition relative to the oscillation. Spike time advancement with IPSP was abolished by the h-channel blocker ZD7288 (10 microM), suggesting that IPSPs can interact with intrinsic membrane conductances to yield bidirectional control of spike timing.
Bonios, Michael J; Selzman, Craig H; Gilbert, Edward M; McKellar, Stephen H; Koliopoulou, Antigoni; Strege, Jennifer L; Nativi, Jose N; Fang, James C; Stehlik, Josef; Drakos, Stavros G
We present the case of two patients with idiopathic dilated cardiomyopathy and moderate aortic valve regurgitation that were treated with a bioprosthetic valve at the time of the left ventricular assist device (LVAD) implantation. A few months later, patients revealed partial recovery in the left ventricle systolic function. Both patients, during the LVAD turndown protocol, reported the onset of chest pain. The transthoracic echocardiography revealed the presence of a new transaortic pressure gradient. We confirmed the presence of a fused bioprosthetic valve by further performing a transesophageal echocardiogram and a left and right heart catheterization. Replacement of aortic valve at the time of an LVAD implantation constitutes a challenging case. Although a mechanical valve is contraindicated due to the increased thromboembolic risk, selecting a bioprosthetic valve increases the risk of valve leaflets fusion. The consequences of this phenomenon should be acknowledged in LVAD patients undergoing aortic valve replacement with a bioprosthetic, especially under the view of LVAD explantation for those revealing myocardial recovery under mechanical unloading.
Sinusoidal voltage protocols for rapid characterisation of ion channel kinetics.
Beattie, Kylie A; Hill, Adam P; Bardenet, Rémi; Cui, Yi; Vandenberg, Jamie I; Gavaghan, David J; de Boer, Teun P; Mirams, Gary R
2018-03-24
Ion current kinetics are commonly represented by current-voltage relationships, time constant-voltage relationships and subsequently mathematical models fitted to these. These experiments take substantial time, which means they are rarely performed in the same cell. Rather than traditional square-wave voltage clamps, we fitted a model to the current evoked by a novel sum-of-sinusoids voltage clamp that was only 8 s long. Short protocols that can be performed multiple times within a single cell will offer many new opportunities to measure how ion current kinetics are affected by changing conditions. The new model predicts the current under traditional square-wave protocols well, with better predictions of underlying currents than literature models. The current under a novel physiologically relevant series of action potential clamps is predicted extremely well. The short sinusoidal protocols allow a model to be fully fitted to individual cells, allowing us to examine cell-cell variability in current kinetics for the first time. Understanding the roles of ion currents is crucial to predict the action of pharmaceuticals and mutations in different scenarios, and thereby to guide clinical interventions in the heart, brain and other electrophysiological systems. Our ability to predict how ion currents contribute to cellular electrophysiology is in turn critically dependent on our characterisation of ion channel kinetics - the voltage-dependent rates of transition between open, closed and inactivated channel states. We present a new method for rapidly exploring and characterising ion channel kinetics, applying it to the hERG potassium channel as an example, with the aim of generating a quantitatively predictive representation of the ion current. We fitted a mathematical model to currents evoked by a novel 8 second sinusoidal voltage clamp in CHO cells overexpressing hERG1a. The model was then used to predict over 5 minutes of recordings in the same cell in response to further protocols: a series of traditional square step voltage clamps, and also a novel voltage clamp comprising a collection of physiologically relevant action potentials. We demonstrate that we can make predictive cell-specific models that outperform the use of averaged data from a number of different cells, and thereby examine which changes in gating are responsible for cell-cell variability in current kinetics. Our technique allows rapid collection of consistent and high quality data, from single cells, and produces more predictive mathematical ion channel models than traditional approaches. © 2018 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.
Chang, Ru-Wen; Chang, Chun-Yi; Lai, Liang-Chuan; Wu, Ming-Shiou; Young, Tai-Horng; Chen, Yih-Sharng; Wang, Chih-Hsien; Chang, Kuo-Chu
2017-01-19
Arterial wave transit time (τ w ) in the lower body circulation is an effective biomarker of cardiovascular risk that substantially affects systolic workload imposed on the heart. This study evaluated a method for determining τ w from the vascular impulse response on the basis of the measured aortic pressure and an assumed triangular flow (Q tri ). The base of the unknown Q tri was constructed with a duration set equal to ejection time. The timing of the peak triangle was derived using a fourth-order derivative of the pressure waveform. Values of τ w s obtained using Q tri were compared with those obtained from the measure aortic flow wave (Q m ). Healthy rats (n = 27), rats with chronic kidney disease (CKD; n = 22), and rats with type 1 (n = 22) or type 2 (n = 11) diabetes were analyzed. The cardiovascular conditions in the CKD rats and both diabetic groups were characterized by a decrease in τ w s. The following significant relation was observed (P < 0.0001): τ w triQ = -1.5709 + 1.0604 × τ w mQ (r 2 = 0.9641). Our finding indicates that aortic impulse response can be an effective method for the estimation of arterial τ w by using a single pressure recording together with the assumed Q tri .
Distributions-per-level: a means of testing level detectors and models of patch-clamp data.
Schröder, I; Huth, T; Suitchmezian, V; Jarosik, J; Schnell, S; Hansen, U P
2004-01-01
Level or jump detectors generate the reconstructed time series from a noisy record of patch-clamp current. The reconstructed time series is used to create dwell-time histograms for the kinetic analysis of the Markov model of the investigated ion channel. It is shown here that some additional lines in the software of such a detector can provide a powerful new means of patch-clamp analysis. For each current level that can be recognized by the detector, an array is declared. The new software assigns every data point of the original time series to the array that belongs to the actual state of the detector. From the data sets in these arrays distributions-per-level are generated. Simulated and experimental time series analyzed by Hinkley detectors are used to demonstrate the benefits of these distributions-per-level. First, they can serve as a test of the reliability of jump and level detectors. Second, they can reveal beta distributions as resulting from fast gating that would usually be hidden in the overall amplitude histogram. Probably the most valuable feature is that the malfunctions of the Hinkley detectors turn out to depend on the Markov model of the ion channel. Thus, the errors revealed by the distributions-per-level can be used to distinguish between different putative Markov models of the measured time series.
Eide, Leslie S P; Ranhoff, Anette H; Fridlund, Bengt; Haaverstad, Rune; Hufthammer, Karl Ove; Kuiper, Karel K J; Nordrehaug, Jan Erik; Norekvål, Tone M
2016-10-05
To determine whether postoperative delirium predicts first-time readmissions and mortality in octogenarian patients within 180 days after aortic valve therapy with surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI), and to determine the most common diagnoses at readmission. Prospective cohort study of patients undergoing elective SAVR or TAVI. Tertiary university hospital that performs all SAVRs and TAVIs in Western Norway. Patients 80+ years scheduled for SAVR or TAVI and willing to participate in the study were eligible. Those unable to speak Norwegian were excluded. Overall, 143 patients were included, and data from 136 are presented. The primary outcome was a composite variable of time from discharge to first all-cause readmission or death. Secondary outcomes were all-cause first readmission alone and mortality within 180 days after discharge, and the primary diagnosis at discharge from first-time readmission. Delirium was assessed with the confusion assessment method. First-time readmissions, diagnoses and mortality were identified in hospital information registries. Delirium was identified in 56% of patients. The effect of delirium on readmissions and mortality was greatest during the first 2 months after discharge (adjusted HR 2.9 (95% CI 1.5 to 5.7)). Of 30 first-time readmissions occurring within 30 days, 24 (80%) were patients who experienced delirium. 1 patient (non-delirium group) died within 30 days after therapy. Delirious patients comprised 35 (64%) of 55 first-time readmissions occurring within 180 days. Circulatory system diseases and injuries were common causes of first-time readmissions within 180 days in delirious patients. 8 patients died 180 days after the procedure; 6 (75%) of them experienced delirium. Delirium in octogenarians after aortic valve therapy might be a serious risk factor for postoperative morbidity and mortality. Cardiovascular disorders and injuries were associated with first-time readmissions in these patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Rathod, Krishnaraj S; Koganti, Sudheer; Iqbal, M Bilal; Jain, Ajay K; Kalra, Sundeep S; Astroulakis, Zoe; Lim, Pitt; Rakhit, Roby; Dalby, Miles C; Lockie, Tim; Malik, Iqbal S; Knight, Charles J; Whitbread, Mark; Mathur, Anthony; Redwood, Simon; MacCarthy, Philip A; Sirker, Alexander; O'Mahony, Constantinos; Wragg, Andrew; Jones, Daniel A
2018-02-01
Cardiogenic shock remains a major cause of morbidity and mortality in patients with ST-segment elevation myocardial infarction. We aimed to assess the current trends in cardiogenic shock management, looking specifically at the incidence, use of intra-aortic balloon pump therapy and outcomes in patients with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention. We undertook an observational cohort study of 21,210 ST-segment elevation myocardial infarction patients treated between 2005-2015 at the eight Heart Attack Centres in London, UK. Patients' details were recorded at the time of the procedure into local databases using the British Cardiac Intervention Society percutaneous coronary intervention dataset. There were 1890 patients who presented with cardiogenic shock. The primary outcome was all-cause mortality at a median follow-up of 4.1 years (interquartile range: 2.2-5.8 years). Increasing rates of cardiogenic shock were seen over the course of the study with consistently high mortality rates of 45-70%. A total of 685 patients underwent intra-aortic balloon pump insertion during primary percutaneous coronary intervention for cardiogenic shock with decreasing rates over time. Those patients undergoing intra-aortic balloon pump therapy were younger, more likely to have poor left ventricular function and less likely to have had previous percutaneous coronary intervention compared to the control group. Procedural success rates were similar (86.0% vs 87.1%, p=0.292) although crude, in-hospital major adverse cardiac event rates were higher (43.8% vs 33.7%, p<0.0001) in patients undergoing intra-aortic balloon pump therapy. Kaplan-Meier analysis demonstrated significantly higher mortality rates in patients receiving intra-aortic balloon pump therapy (50.9% intra-aortic balloon pump vs 39.9% control, p<0.0001) during the follow-up period. After multivariate Cox analysis (hazard ratio 1.04, 95% confidence interval 0.62-1.89) and the use of propensity matching (hazard ratio: 1.29, 95% confidence interval: 0.68-1.45) intra-aortic balloon pump therapy was not associated with mortality. Cardiogenic shock treated by percutaneous coronary intervention is increasing in incidence and remains a condition associated with high mortality and limited treatment options. Intra-aortic balloon pump therapy was not associated with a long-term survival benefit in this cohort and may be associated with increased early morbidity.
Acute resistance exercise using free weights on aortic wave reflection characteristics.
Tai, Yu Lun; Gerhart, Hayden; Mayo, Xián; Kingsley, J Derek
2018-01-01
Aortic wave reflection characteristics such as the augmentation index (AIx), wasted left ventricular pressure energy (ΔE w ) and aortic haemodynamics, such as aortic systolic blood pressure (ASBP), strongly predict cardiovascular events. The effects of acute resistance exercise (ARE) using free-weight exercises on these characteristics are unknown. Therefore, we sought to determine the effects of acute free-weight resistance exercise on aortic wave reflection characteristics and aortic haemodynamics in resistance-trained individuals. Fifteen young, healthy resistance-trained (9 ± 3 years) individuals performed two randomized sessions consisting of an acute bout of free-weight resistance exercise (ARE) or a quiet control (CON). The ARE consisted of three sets of 10 repetitions at 75% one repetition maximum for squat, bench press and deadlift. In CON, the participants rested in the supine position for 30 min. Measurements were made at baseline before sessions and 10 min after sessions. A two-way ANOVA was used to compare the effects of condition across time. There were no significant interactions for aortic or brachial blood pressures. Compared to rest, there were significant increases in augmentation pressure (rest: 5·7 ± 3·0 mmHg; recovery: 10·4 ± 5·7 mmHg, P = 0·002), AIx (rest: 116·8 ± 4·2%; recovery: 123·2 ± 8·4%, P = 0·002), AIx normalized at 75 bpm (rest: 5·2 ± 7·6%; recovery: 27·3 ± 13·2%, P<0·0001), ΔE w (rest: 1215 ± 674 dynes s cm -2 ; recovery: 2096 ± 1182 dynes s cm -2 , P = 0·008), and there was a significant decrease in transit time of the reflected wave (rest: 150·7 ± 5·8 ms; recovery 145·5 ± 5·6 ms, P<0·001) during recovery from ARE compared to CON. These data suggest that ARE using free-weight exercises may have no effect on aortic and brachial blood pressure but may significantly alter aortic wave reflection characteristics. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Trinh, Brian; Dubin, Iram; Rahman, Ozair; Ferreira Botelho, Marcos P; Naro, Nicholas; Carr, James C; Collins, Jeremy D; Barker, Alex J
2017-04-01
Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P < 0.05, significant). The diameter of maximal growth (DMG), defined as the diameter at SOV or MAA with the faster growth rate, was recorded. The mean time of follow-up was 2.6 ± 0.82 years. The intraobserver COV was 0.01 for SOV, 0.02 for MAA, and 0.02 for volume (interobserver COV: 0.02, 0.03, 0.04, respectively). The ICC was 0.83 for SOV, 0.86 for MAA, 0.90 for DMG, and 0.95 for volume. Average aortic measurements at baseline and (follow-up) were 42 ± 3 mm (42 ± 3 mm, P = 0.11) at SOV, 46 ± 4 mm (47 ± 4 mm, P < 0.05) at MAA, and 130 ± 23 mL (144 ± 24 mL, P < 0.05). Average size changes were 0.2 ± 0.6 mm/y (1% ± 2%) at SOV, 0.5 ± 0.8 mm/y (1% ± 2%) at MAA, 0.7 ± 0.7 mm/y (2% ± 2%) at DMG, and 6 ± 3 mL/y (4% ± 3%) with volumetry. Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.
The Influence of Blood Pressure on Fetal Aortic Distensibility: An Animal Validation Study.
Wohlmuth, Christoph; Moise, Kenneth J; Papanna, Ramesha; Gheorghe, Ciprian; Johnson, Anthony; Morales, Yisel; Gardiner, Helena M
2018-01-01
Aortic distension waveforms describe the change in diameter or cross-sectional area over the cardiac cycle. We aimed to validate the association of aortic fractional area change (AFAC) with blood pressure (BP) in a fetal lamb model. Four pregnant ewes underwent open fetal surgery under general anesthesia at 107-120 gestational days. A 4-Fr catheter was introduced into the fetal femoral artery and vein, or the carotid artery and jugular vein. The thoracic aorta was imaged using real-time ultrasound; AFAC was calculated using offline speckle tracking software. Measurements of invasive BP and AFAC were obtained simultaneously and averaged over 10 cardiac cycles. BP was increased by norepinephrine infusion and the association of aortic distensibility with BP was assessed. Baseline measurements were obtained from 4 lambs, and changes in aortic distensibility with increasing BP were recorded from 3 of them. A positive correlation was found between AFAC and systolic BP (r = 0.692, p = 0.001), diastolic BP (r = 0.647, p = 0.004), mean BP (r = 0.692, p = 0.001), and BP amplitude (r = 0.558, p = 0.016) controlled for heart rate. No association was found between BP and maximum or minimum aortic area. AFAC provides a quantifiable measure of aortic distensibility and correlates with systolic BP, diastolic BP, mean BP, and BP amplitude in a fetal lamb model. © 2017 S. Karger AG, Basel.
Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.
2017-01-01
Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998
Transcription Factor Runx2 Promotes Aortic Fibrosis and Stiffness in Type 2 Diabetes Mellitus.
Raaz, Uwe; Schellinger, Isabel N; Chernogubova, Ekaterina; Warnecke, Christina; Kayama, Yosuke; Penov, Kiril; Hennigs, Jan K; Salomons, Florian; Eken, Suzanne; Emrich, Fabian C; Zheng, Wei H; Adam, Matti; Jagger, Ann; Nakagami, Futoshi; Toh, Ryuji; Toyama, Kensuke; Deng, Alicia; Buerke, Michael; Maegdefessel, Lars; Hasenfuß, Gerd; Spin, Joshua M; Tsao, Philip S
2015-08-28
Accelerated arterial stiffening is a major complication of diabetes mellitus with no specific therapy available to date. The present study investigates the role of the osteogenic transcription factor runt-related transcription factor 2 (Runx2) as a potential mediator and therapeutic target of aortic fibrosis and aortic stiffening in diabetes mellitus. Using a murine model of type 2 diabetes mellitus (db/db mice), we identify progressive structural aortic stiffening that precedes the onset of arterial hypertension. At the same time, Runx2 is aberrantly upregulated in the medial layer of db/db aortae, as well as in thoracic aortic samples from patients with type 2 diabetes mellitus. Vascular smooth muscle cell-specific overexpression of Runx2 in transgenic mice increases expression of its target genes, Col1a1 and Col1a2, leading to medial fibrosis and aortic stiffening. Interestingly, increased Runx2 expression per se is not sufficient to induce aortic calcification. Using in vivo and in vitro approaches, we further demonstrate that expression of Runx2 in diabetes mellitus is regulated via a redox-sensitive pathway that involves a direct interaction of NF-κB with the Runx2 promoter. In conclusion, this study highlights Runx2 as a previously unrecognized inducer of vascular fibrosis in the setting of diabetes mellitus, promoting arterial stiffness irrespective of calcification. © 2015 American Heart Association, Inc.
MDCT distinguishing features of focal aortic projections (FAP) in acute clinical settings.
Valente, Tullio; Rossi, Giovanni; Lassandro, Francesco; Rea, Gaetano; Marino, Maurizio; Urciuolo, Salvatore; Tortora, Giovanni; Muto, Maurizio
2015-01-01
Focal aortic projections (FAP) are protrusion images of the contrast medium (focal contour irregularity, breaks in the intimal contour, outward lumen bulging or localized blood-filled outpouching) projecting beyond the aortic lumen in the aortic wall and are commonly seen on multidetector computed tomography (MDCT) scans of the chest and abdomen. FAP include several common and uncommon etiologies, which can be demonstrated both in the native aorta, mainly in acute aortic syndromes, and in the post-surgical aorta or after endovascular therapy. They are also found in some types of post-traumatic injuries and in impending rupture of the aneurysms. The expanding, routine use of millimetric or submillimetric collimation of current state-of-the-art MDCT scanners (16 rows and higher) all the time allows the identification and characterization of these small ulcer-like lesions or irregularities in the entire aorta, as either an incidental or expected finding, and provides detailed three-dimensional pictures of these pathologic findings. In this pictorial review, we illustrate the possible significance of FAP and the discriminating MDCT features that help to distinguish among different types of aortic protrusions and their possible evolution. Awareness of some related and distinctive radiologic features in FAP may improve our understanding of aortic diseases, provide further insight into the pathophysiology and natural history, and guide the appropriate management of these lesions.
Li, Zhuo-Dong; Liu, Yang; Zhu, Jiang; Wang, Jun; Lu, Fang-Lin; Han, Lin; Xu, Zhi-Yun
2017-12-01
Aortic rupture is one of the main causes of early death in acute and subacute Stanford type A aortic dissection (ATAAD) patients. This study aimed to analyze potential risk factors for pre-operational aortic rupture in ATAAD patients. We retrospectively reviewed aortic dissection cases treated between May 2013 and May 2016 in Changhai Hospital, Shanghai. A total of 329 patients with ATAAD were included in the final analysis, and 31 patients died of aortic rupture before surgery. Clinical data on basic characteristics, clinical presentation, and biochemical measurements for all 329 patients were analyzed. The in-hospital aortic rupture rate was 9.4% (31/329), and the rupture accounted for 47% (31/66) of all in-hospital deaths of ATAAD patients. Patients who experienced rupture were significantly older (P<0.001), had lower systolic blood pressure (P=0.040), had more painful manifestation (P<0.001), had more systematic complications [shock (P=0.001), coma (P<0.001), hypoxemia (P=0.006), kidney and liver dysfunctions, and myocardial injury (higher troponin, P=0.009)], and had worse blood coagulability [lower platelet count (P=0.012), longer prothrombin time (P<0.001), and higher D-dimer (P=0.003)]. Multivariable analysis identified the following independent risk factors: shock [odds ratio (OR): 8.12; 95% confidence interval (CI), 1.10-59.85, P=0.040], pain requiring medication (OR: 12.67; 95% CI, 2.43-66.09; P=0.003), troponin level >0.7 ng/mL (OR: 9.28; 95% CI, 1.72-50.06; P=0.010), and D-dimer level ≥10 µg/mL (OR: 13.37; 95% CI, 2.18-81.97; P=0.005). Aortic rupture accounted for 47% of all in-hospital deaths among patient with ATAAD. Shock, pain requiring medication, a troponin level >0.7 ng/mL and a D-dimer level ≥10 µg/mL are independent risk factors for aortic rupture in these patients.
Watson, Alanna; Nong, Zengxuan; Yin, Hao; O'Neil, Caroline; Fox, Stephanie; Balint, Brittany; Guo, Linrui; Leo, Oberdan; Chu, Michael W A; Gros, Robert; Pickering, J Geoffrey
2017-06-09
The thoracic aortic wall can degenerate over time with catastrophic consequences. Vascular smooth muscle cells (SMCs) can resist and repair artery damage, but their capacities decline with age and stress. Recently, cellular production of nicotinamide adenine dinucleotide (NAD + ) via nicotinamide phosphoribosyltransferase (Nampt) has emerged as a mediator of cell vitality. However, a role for Nampt in aortic SMCs in vivo is unknown. To determine whether a Nampt-NAD + control system exists within the aortic media and is required for aortic health. Ascending aortas from patients with dilated aortopathy were immunostained for NAMPT, revealing an inverse relationship between SMC NAMPT content and aortic diameter. To determine whether a Nampt-NAD + control system in SMCs impacts aortic integrity, mice with Nampt -deficient SMCs were generated. SMC- Nampt knockout mice were viable but with mildly dilated aortas that had a 43% reduction in NAD + in the media. Infusion of angiotensin II led to aortic medial hemorrhage and dissection. SMCs were not apoptotic but displayed senescence associated-ß-galactosidase activity and upregulated p16, indicating premature senescence. Furthermore, there was evidence for oxidized DNA lesions, double-strand DNA strand breaks, and pronounced susceptibility to single-strand breakage. This was linked to suppressed poly(ADP-ribose) polymerase-1 activity and was reversible on resupplying NAD + with nicotinamide riboside. Remarkably, we discovered unrepaired DNA strand breaks in SMCs within the human ascending aorta, which were specifically enriched in SMCs with low NAMPT. NAMPT promoter analysis revealed CpG hypermethylation within the dilated human thoracic aorta and in SMCs cultured from these tissues, which inversely correlated with NAMPT expression. The aortic media depends on an intrinsic NAD + fueling system to protect against DNA damage and premature SMC senescence, with relevance to human thoracic aortopathy. © 2017 American Heart Association, Inc.
Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.
Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas
2017-06-01
Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.
Aortic dissection in pregnancy in England: an incidence study using linked national databases
Banerjee, Amitava; Begaj, Irena; Thorne, Sara
2015-01-01
Objectives To conduct the first population-level incidence study of aortic dissection in pregnancy using linked hospital-based data in England. Setting Hospital-based data (Hospital Episode Statistics (HES) linked with mortality data from the Office of National Statistics), national enquiries (Confidential Enquiries into Maternal Mortality) and surveys (UK Obstetric Surveillance System; UKOSS) of aortic dissection in pregnancy from 2003 to 2011 in England. Participants Between 2003 and 2011, all female patients admitted with diagnoses of aortic dissection (not necessarily as the primary cause of admission) and of pregnancy, childbirth and puerperium, were included. Outcome measures Diagnosis of aortic dissection during pregnancy, operated or not operated, with outcome of death or live patient from 2003 to 2011 in England. Results There were significant differences in characteristics of databases with respect to study population, time of study, recorded event and follow-up of outcomes. On the basis of HES, annual incidence of aortic dissection was 1.23 (95% CI 1.22 to 1.24) per 100 000 maternities. Incidence of aortic dissection with death within 1 year was 0.30 (0.29 to 0.31) per 100 000 maternities. Incidence of aortic dissection increased from 0.74 (0.73 to 0.75) per 100 000 maternities in 2003–2005 to 1.52 (1.51 to 1.53) per 100 000 maternities in 2009–2011. In the Confidential Enquiries into Maternal Deaths, incidence of deaths was highest for 2003–2005 (0.43/100 000 maternities) and lowest for 1997–1999 (0.21/100 000 maternities). In the UK Obstetric Surveillance System, national incidence of aortic dissection was 0.80 (0.50 to 1.50) per 100 000 maternities between 2009 and 2011. Conclusions The case of aortic dissection in pregnancy illustrates data limitations regarding complications in pregnancy from different sources in the UK, even for a diagnosis with seemingly few alternative coding and diagnostic possibilities. These limitations should be acknowledged when estimating incidence and outcome. PMID:26297370
Cacciamani, Giovanni E; Medina, Luis G; Gill, Tania S; Mendelsohn, Alec; Husain, Fatima; Bhardwaj, Lokesh; Artibani, Walter; Sotelo, Renè; Gill, Inderbir S
2018-02-05
During robotic partial nephrectomy (RPN), various techniques of hilar control have been described, including on-clamp, early unclamping, selective/super-selective clamping, and completely-unclamped RPN. To evaluate the impact of various hilar control techniques on perioperative, functional, and oncological outcomes of RPN for tumors. We conducted a systematic literature review and meta-analysis of all comparative studies on various hilar control techniques during RPN using PubMed, Scopus, and Web of Science according to the Preferred Reporting Items for Systematic Review and Meta-analysis statement, and Methods and Guide for Effectiveness and Comparative Effectiveness Review of the Agency for Healthcare Research and Quality. Cumulative meta-analysis of comparative studies was conducted using Review Manager 5.3. Of 987 RPN publications in the literature, 19 qualified for this analysis. Comparison of off-clamp versus on-clamp RPN (n=9), selective clamping versus on-clamp RPN (n=3), super selective clamping versus on-clamp RPN (n=5), and early unclamped versus on-clamp (n=3) were reported. Patients undergoing RPN using off-clamp, selective/super selective, or early unclamp techniques had higher estimated blood loss compared with on-clamp RPN (weight mean difference [WMD]: 47.83, p=0.000, WMD: 41.06, p=0.02, and WMD: 37.50, p=0.47); however, this did not seem clinically relevant, since transfusion rates were similar (odds ratio [OR]: 0.98, p=0.95, OR: 0.72, p=0.7, and OR: 1.36, p=0.33, respectively). All groups appeared similar with regards to hospital stay, transfusions, overall and major complications, and positive cancer margin rates. Short- and long-term renal functional outcomes appeared superior in the off-clamp and super selective clamp groups compared with the on-clamp RPN cohort. Off-clamp, selective/super selective clamp, and early unclamp hilar control techniques are safe and feasible approaches for RPN surgery, with similar perioperative and oncological outcomes compared with on-clamp RPN. Minimizing global renal ischemia may provide superior renal function preservation. However, higher quality data are necessary for definitive conclusions in this regard. The objective of partial nephrectomy is to treat the cancer while maximizing renal function preservation. Clamping the main vessels is done primarily to reduce the blood loss during partial nephrectomy; however, vascular clamping can compromise kidney function. In order to avoid clamping, various techniques have been described. Our analysis showed that techniques that avoid main renal artery clamping during RPN are associated with better renal function preservation, yet deliver non-inferior perioperative and oncological outcomes as compared with robotic partial nephrectomy procedures that clamp the main vessels. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Mangenah, Collin; Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M; Thirumurthy, Harsha
2015-08-15
Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization.
Styczynski, Grzegorz; Rdzanek, Adam; Pietrasik, Arkadiusz; Kochman, Janusz; Huczek, Zenon; Sobieraj, Piotr; Gaciong, Zbigniew; Szmigielski, Cezary
2016-11-01
Aortic pulse-wave velocity (PWV) is a measure of aortic stiffness that has a prognostic role in various diseases and in the general population. A number of methods are used to measure PWV, including Doppler ultrasound. Although echocardiography has been used for PWV measurement, to the authors' knowledge, it has never been tested against an invasive reference method at the same time point. Therefore, the aim of this study was to compare prospectively an echocardiographic PWV measurement, called echo-PWV, with an invasive study. Forty-five patients (mean age, 66 years; 60% men) underwent simultaneous intra-arterial pressure recording and echocardiographic Doppler flow evaluation during elective cardiac catheterization. Proximal pressure and Doppler waveforms were acquired in the aortic arch. Distal pressure waveforms were registered in the right and distal Doppler waveforms in the left external iliac artery. Transit time was measured as a delay of the foot of pressure or Doppler waveform in the distal relative to the proximal location. Distance was measured on the catheter for invasive PWV and over the surface for echo-PWV. Echo-PWV was calculated as distance divided by transit time. In the whole group, mean invasive PWV was 9.38 m/sec and mean echo-PWV was 9.51 m/sec (P = .78). The Pearson' correlation coefficient between methods was 0.93 (P < .0001). A Bland-Altman plot revealed a mean difference between invasive PWV and echo-PWV of 0.13 ± 0.79 m/sec. Echo-PWV, based on Doppler echocardiography, is a reliable method of aortic PWV measurement, with a close correlation with invasive assessment. Wider implementation of the echo-PWV method for the evaluation of aortic wall stiffness can further expand the clinical and scientific utility of echocardiography. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Jakobsdóttir, S; Twisk, J W R; Drent, M L
2009-12-01
In studies investigating the influence of glucose levels on the pituitary function the methods used have been variable and mainly focused on the change in function as a reaction to unphysiological low or high blood glucose levels. In the present study the impact of physiological and elevated blood glucose levels on adrenocorticotropin hormone (ACTH) and growth hormone release are investigated. The euglycaemic and hyperglycaemic clamp techniques were used to reach stable levels of 4, 8 and 12 mmol/l blood glucose levels. After a stabilization phase of 2 h, a corticotropin releasing hormone (CRH) or a growth hormone releasing hormone (GHRH) stimulation test was performed. Seven and eight healthy male volunteers, belonging to two groups, participated in this study. The area under the curve (AUC), peak values and time to peak of ACTH, cortisol and growth hormone were calculated to evaluate the response to the CRH and GHRH stimulation test. The peak values of ACTH, cortisol and growth hormone seemed to be the highest during the 4 mmol/l clamp sessions, compared with the 8 and 12 mmol/l clamps, although the differences were not statistically significant when analysed for every subject individually. The AUC and time to peak measurements were comparable during the three clamp procedures. The pituitary reaction on CRH and GHRH was not significantly changed by various blood glucose levels. © 2009 Blackwell Publishing Ltd.
Clamp usable as jig and lifting clamp
Tsuyama, Yoshizo
1976-01-01
There is provided a clamp which is well suited for use as a lifting clamp for lifting and moving materials of assembly in a shipyard, etc. and as a pulling jig in welding and other operations. The clamp comprises a clamp body including a shackle for engagement with a pulling device and a slot for receiving an article, and a pair of jaws provided on the leg portions of the clamp body on the opposite sides of the slot to grip the article in the slot, one of said jaws consisting of a screw rod and the other jaw consisting of a swivel jaw with a spherical surface, whereby when the article clamped in the slot by the pair of jaws tends to slide in any direction with respect to the clamp body, the article is more positively gripped by the pair of jaws.
Cable clamp bolt fixture facilitates assembly in close quarters
NASA Technical Reports Server (NTRS)
Sunderland, G. H.
1967-01-01
Cable clamp bolt holding fixture facilitates forming of electrical cable runs in limited equipment space. The fixture engages the threads of the short clamp bolt through the clamp and maintains tension against clamp tendency to open while the operator installs the nut without difficulty.
Cold crystalloid versus warm blood cardioplegia in patients undergoing aortic valve replacement.
Nardi, Paolo; Vacirca, Sara R; Russo, Marco; Colella, Dionisio F; Bassano, Carlo; Scafuri, Antonio; Pellegrino, Antonio; Melino, Gerry; Ruvolo, Giovanni
2018-03-01
Myocardial protection techniques during cardiac arrest have been extensively investigated in the clinical setting of coronary revascularization. Fewer studies have been carried out of patients affected by left ventricular hypertrophy, where the choice of type and temperature of cardioplegia remain controversial. We have retrospectively investigated myocardial injury and short-term outcome in patients undergoing aortic valve replacement plus or minus coronary artery bypass grafting with using cold crystalloid cardioplegia (CCC) or warm blood cardioplegia (WBC). From January 2015 to October 2016, 191 consecutive patients underwent aortic valve replacement plus or minus coronary artery bypass grafting in normothermic cardiopulmonary bypass. Cardiac arrest was obtained with use of intermittent antegrade CCC group (n=32) or WBC group (n=159), according with the choice of the surgeon. As compared with WBC group, in CCC group creatine-kinase-MB (CK-MB), cardiac troponin I (cTnI), aspartate aminotransferase (AST) release, and their peak levels, were lower during each time points of evaluation, with the greater statistically significant difference at time 0 (P<0.05, for all comparisons). A time 0, CK-MB/CK ratio >10% was 5.9% in CCC group versus 7.8% in WBC group (P<0.0001). At time 0 CK-MB/CK ratio >10% in patients undergoing isolated aortic valve replacement was 6.0% in CCC group versus 8.0% in WBC group (P<0.01). No any difference was found in perioperative myocardial infarction (0% versus 3.8%), postoperative (PO) major complications (15.6% versus 16.4%), in-hospital mortality (3.1% versus 1.3%). In aortic valve surgery a significant decrease of myocardial enzymes release is observed in favor of CCC, but this difference does not translate into different clinical outcome. However, this study suggests that in presence of cardiac surgical conditions associated with significant left ventricular hypertrophy, i.e., the aortic valve disease, a better myocardial protection can be achieved with the use of a cold rather than a warm cardioplegia. Therefore, CCC can be still safely used.
Split-tapered joint clamping device
Olsen, Max J.; Schwartz, Jr., John F.
1988-01-01
This invention relates to a clamping device for removably attaching a tool element to a bracket element wherein a bracket element is disposed in a groove in the tool and a clamping member is disposed in said groove and in engagement with a clamping face of the bracket and a wall of the groove and with the clamping member having pivot means engaging the bracket and about which the clamping member rotates.
Trauzeddel, Ralf Felix; Löbe, Ulrike; Barker, Alex J; Gelsinger, Carmen; Butter, Christian; Markl, Michael; Schulz-Menger, Jeanette; von Knobelsdorff-Brenkenhoff, Florian
2016-03-01
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7%, respectively), whereas controls showed central blood flow (88.9%). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.
Late post-AVR progression of bicuspid aortopathy: link to hemodynamics.
Naito, Shiho; Gross, Tatiana; Disha, Kushtrim; von Kodolitsch, Yskert; Reichenspurner, Hermann; Girdauskas, Evaldas
2017-05-01
The ascending aortic dilatation may progress after aortic valve replacement (AVR) in bicuspid aortic valve (BAV) patients. Our aim was to evaluate rheological flow patterns and histological characteristics of the aneurysmal aorta in BAV patients at the time of reoperative aortic surgery. 13 patients (mean age: 42 ± 9 years, 10 (77%) male) with significant progression of proximal aortopathy after isolated AVR surgery for BAV disease (i.e., 16.7 ± 8.1 years post-AVR) were identified by cardiac phase-contrast cine magnetic resonance imaging (MRI) in our hospital. A total of nine patients (69%) underwent redo aortic surgery. Based on the MRI data, the aortic area of the maximal flow-induced stress (jet sample) and the opposite site (control sample) were identified and corresponding samples were collected intraoperatively. Histological sum-score values [i.e. aortic wall changes were graded based on a summation of seven histological criteria (each scored from 0 to 3)] were compared between these samples. Mean proximal aortic diameter at MRI follow-up was 55 ± 6 mm (range 47-66mm). Preoperative cardiac MRI demonstrated eccentric systolic flow pattern directed towards right-lateral/right posterior wall of the proximal aorta in 9/13 (69%) patients. Histological sum-score values were significantly higher in the jet sample vs control sample (i.e., 8.3 ± 3.8 vs 5.6 ± 2.4, respectively, p = 0.04). Hemodynamic factors may still be involved in the late progression of bicuspid aortopathy even after isolated AVR surgery for BAV disease.
[Prevention of cerebrovascular complications in coronary artery bypass grafting].
Mialiuk, P A; Marchenko, A V; Arutiunian, V B; Chragian, V A; Alekseevich, G Iu; Vronskiĭ, A S
The authors carried out a comparative analysis of the incidence rate of cerebrovascular complications following coronary artery bypass grafting performed using either a differentiated approach to surgical policy depending on the findings of epiaortic ultrasonographic scanning or the standard conventional approach. A total of 3,454 operations of coronary artery bypass grafting were performed. All patients were divided into two groups. Patients of the Study Group (n=765) were subjected to obligatory intraoperative epiaortic scanning, with the variant of further surgical intervention depending on the obtained findings of the examination. The Control Group patients (n=2,689) underwent standard coronary artery bypass grafting in the conditions of artificial circulation (AC). In the Study Group patients, depending on the degree and localization of the atherosclerotic lesion of the aorta, determined by the findings of epiaortic scanning, one of the following techniques of coronary artery bypass grafting (CABG) was chosen: cases with no lesion were managed by CABG with AC (585 patients); a local solitary lesion was managed by altering the site of cannulation and application of the clamp (92 patients) or by the operation according to the 'single clamp' technique (43 patients); cases of manifested atherosclerosis of the ascending aorta were treated by the 'on-pump beating-heart' technique in the conditions of AC without placing clamps (27 patients); cases of massive involvement of the ascending aorta and aortic arch were managed by CABG performed according to the 'no-touch aorta' technique (18 patients). The total mortality rate amounted to 1.1%. Thirty-three (0.96%) patients in the postoperative period were found to have ischaemic stroke. The mortality rate in the Control Group amounted to 1.4% and that in the Study Group equalled 0.3%, with the number of cases of ischaemic strokes amounting to 33 (1.4%) and 0, respectively. Perioperative infarction was diagnosed in 16 (0.6%) cases in the Control Group and in 5 (0.7%) patients in the group treated using the differentiated approach. A conclusion was drawn that the differentiated approach to choosing the technique of CABG based on the findings obtained by means of epiaortic scanning was associated with a statistically significant decrease in both the number of ischaemic strokes and the mortality rate after CABG operations.
Koutroumbas, Georgios; Georgianos, Panagiotis I.; Sarafidis, Pantelis A.; Protogerou, Athanase; Karpetas, Antonios; Vakianis, Pantelis; Raptis, Vassilios; Liakopoulos, Vassilios; Panagoutsos, Stylianos; Syrganis, Christos; Passadakis, Ploumis
2015-01-01
Background Increased arterial stiffness and aortic blood pressure (BP) are independent predictors of cardiovascular outcomes in end-stage renal disease. The 3-day interdialytic interval is associated with elevated risk of cardiovascular morbidity and mortality in haemodialysis. This study investigated differences in ambulatory aortic BP and arterial stiffness between the second and third day of the long interdialytic interval. Methods Ambulatory BP monitoring with Mobil-O-Graph monitor (IEM, Stolberg, Germany) was performed in 55 haemodialysis patients during a 3-day interval. Mobil-O-Graph records oscillometric brachial BP and pulse waves and calculates aortic BP and augmentation index (AIx) as measure of wave reflections, and pulse wave velocity (PWV) as measure of arterial stiffness. Results Ambulatory aortic systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher during the third versus second interdialytic day (123.6 ± 17.0 versus 118.5 ± 17.1 mmHg, P < 0.001; 81.5 ± 11.8 versus 78 ± 11.9 mmHg, P < 0.001, respectively). Similar differences were noted for brachial BP. Ambulatory AIx and PWV were also significantly increased during the third versus second day (30.5 ± 9.9 versus 28.8 ± 9.9%, P < 0.05; 9.6 ± 2.3 versus 9.4 ± 2.3 m/s, P < 0.001, respectively). Differences between Days 2 and 3 remained significant when day-time and night-time periods were compared separately. Aortic SBP and DBP, AIx and PWV showed gradual increases from the end of dialysis session onwards. Interdialytic weight gain was a strong determinant of the increase in the above parameters. Conclusions This study showed significantly higher ambulatory aortic BP, AIx and PWV levels during the third compared with the second interdialytic day. These findings support a novel pathway for increased cardiovascular risk during the third interdialytic day in haemodialysis. PMID:25920919
Ghosh, Payel; Chandler, Adam G; Hobbs, Brian P; Sun, Jia; Rong, John; Hong, David; Subbiah, Vivek; Janku, Filip; Naing, Aung; Hwu, Wen-Jen; Ng, Chaan S
The aim of this study was to quantify the effect of shuttling on computed tomography perfusion (CTp) parameters derived from shuttle-mode body CT images using aortic inputs from different table positions. Axial shuttle-mode CT scans were acquired from 6 patients (10 phases, 2 nonoverlapping table positions 1.4 seconds apart) after contrast agent administration. Artifacts resulting from the shuttling motion were corrected with nonrigid registration before computing CTp maps from 4 aortic levels chosen from the most superior and inferior slices of each table position scan. The effect of shuttling on CTp parameters was estimated by mean differences in mappings obtained from aortic inputs in different table positions. Shuttling effect was also quantified using 95% limits of agreement of CTp parameter differences within-table and between-table aortic positions from the interaortic mean CTp values. Blood flow, permeability surface, and hepatic arterial fraction differences were insignificant (P > 0.05) for both within-table and between-table comparisons. The 95% limits of agreement for within-table blood volume (BV) value deviations obtained from lung tumor regions were less than 4.7% (P = 0.18) compared with less than 12.2% (P = 0.003) for between-table BV value deviations. The 95% limits of agreement of within-table deviations for liver tumor regions were less than 1.9% (P = 0.55) for BV and less than 3.2% (P = 0.23) for mean transit time, whereas between-table BV and mean transit time deviations were less than 11.7% (P < 0.01) and less than 14.6% (P < 0.01), respectively. Values for normal liver tissue regions were concordant. Computed tomography perfusion parameters acquired from aortic levels within-table positions generally yielded higher agreement than mappings obtained from aortic levels between-table positions indicating differences due to shuttling effect.
Onk, Oruc Alper; Erkut, Bilgehan
2015-10-01
This study examined the influence of preoperative administration of amiodarone and metoprolol in preventing postoperative atrial fibrillation (AF) after coronary artery bypass grafting (CABG) surgery.The study comprised 251 patients who underwent CABG surgery at our hospital between January 2012 and May 2014. The patients were randomly divided into 2 groups: amiodarone therapy group (n = 122 patients) and metoprolol therapy group (n = 129 patients).In the amiodarone group, the patients received amiodarone tablet orally 1 week before coronary bypass surgery and during the postoperative period. In the metoprolol group, the patients received metoprolol tablet orally 1 week before surgery and during the postoperative period. The AF development rate was retrospectively evaluated between the first 3 days and 4 weeks after surgery.AF developed in 14 patients in the amiodarone group and 16 patients in the metoprolol group 4 weeks after the operation (P = 0.612).No significant difference was observed between the groups in terms of intensive care unit and hospital stay. Furthermore, hospital charges were similar in both groups (P = 0.741).The results of the logistic regression analysis showed age, left ventricular ejection fraction, left atrial diameter, and aortic cross-clamping time to be predictors for postoperative AF.This study demonstrates that amiodarone and metoprolol have similar effects in prevention of AF after cardiac surgery. However, larger-scale studies need to be conducted to substantiate these findings.
Zanobini, Marco; Ricciardi, Gabriella; Mammana, Francesco Liborio; Kassem, Samer; Poggio, Paolo; Di Minno, Alessandro; Cavallotti, L; Saccocci, Matteo
2017-09-01
Leaflet resection represents the reference standard for surgical treatment of mitral valve (MV) regurgitation. New approaches recently proposed place emphasis on respecting, rather than resecting, the leaflet tissue to avoid the drawbacks of the 'resection' approach. The lateral dislocation of mid portion of mitral posterior leaflet (P2) technique for MV repair is a nonresectional technique in which the prolapsed P2 segment is sutured to normal P1 segment. Our study evaluates the effectiveness of this technique. We performed the procedure on seven patients. Once ring annular sutures were placed, the prolapsed P2 segment was dislocated toward the normal P1 segment with a rotation of 90° and without any resection. If present, residual clefts between P2 and P3 segments were closed. Once the absence of residual mitral regurgitation is confirmed by saline pressure test, ring annuloplasty was completed. The valve was evaluated using transesophageal echocardiography in the operating room and by transthoracic echocardiography before discharge. At the last follow-up visit, transthoracic echocardiography revealed no mitral regurgitation and normal TRANSVALVULAR gradients. The lateral dislocation of P2 is an easily fine-tuned technique for isolated P2 prolapse, with the advantage of short aortic cross-clamp and cardiopulmonary bypass times. We think it might be very favorable in older and frail patients. Long-term follow-up is necessary to assess the durability of this technique.
A miniaturized planar patch-clamp system for transportable use.
Boussaoud, Adrien; Fonteille, Isabelle; Collier, Guilhem; Kermarrec, Frédérique; Vermont, Fabien; Tresallet, Eric; De Waard, Michel; Arnoult, Christophe; Picollet-D'hahan, Nathalie
2012-02-15
In the last decade, planar patch-clamp (PPC) has emerged as an innovative technology allowing parallel recordings of cellular electrophysiological activity on planar substrates. If PPC is widely adopted by the pharmaceutical sector, it remains poorly extended to other areas (i.e. environment and safety organizations) probably because of the large, expensive and non-easily transportable format of those commercial equipments. The present work describes for the first time a new compact and transportable planar patch-clamp system (named Toxint'patch or TIP, for Toxin detection with integrated patch-clamp) focusing on environmental matters and meant to be used in coastal laboratories, for direct on-site monitoring of the seawater and shellfish quality. The TIP system incorporates silicon chips tailored to monitor cellular ionic currents from cultured cells stably expressing a phycotoxin molecular target. The functionality of this novel briefcase-sized PPC system is described in terms of fluidic control, electronic performances with amplifying and filtering boards and of user interface for data acquisition and control implemented on a computer. Copyright © 2011 Elsevier B.V. All rights reserved.
Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM
Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi
2017-01-01
Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027
Digital force-feedback for protein unfolding experiments using atomic force microscopy
NASA Astrophysics Data System (ADS)
Bippes, Christian A.; Janovjak, Harald; Kedrov, Alexej; Muller, Daniel J.
2007-01-01
Since its invention in the 1990s single-molecule force spectroscopy has been increasingly applied to study protein (un-)folding, cell adhesion, and ligand-receptor interactions. In most force spectroscopy studies, the cantilever of an atomic force microscope (AFM) is separated from a surface at a constant velocity, thus applying an increasing force to folded bio-molecules or bio-molecular bonds. Recently, Fernandez and co-workers introduced the so-called force-clamp technique. Single proteins were subjected to a defined constant force allowing their life times and life time distributions to be directly measured. Up to now, the force-clamping was performed by analogue PID controllers, which require complex additional hardware and might make it difficult to combine the force-feedback with other modes such as constant velocity. These points may be limiting the applicability and versatility of this technique. Here we present a simple, fast, and all-digital (software-based) PID controller that yields response times of a few milliseconds in combination with a commercial AFM. We demonstrate the performance of our feedback loop by force-clamp unfolding of single Ig27 domains of titin and the membrane proteins bacteriorhodopsin (BR) and the sodium/proton antiporter NhaA.
Kc, Ashish; Målqvist, Mats; Rana, Nisha; Ranneberg, Linda Jarawka; Andersson, Ola
2016-03-10
Delayed cord clamping at birth has shown to benefit neonates with increased placental transfusion leading to higher haemoglobin concentrations, additional iron stores and less anaemia later in infancy, higher red blood cell flow to vital organs and better cardiopulmonary adaptation. As iron deficiency in infants even without anaemia has been associated with impaired development, delayed cord clamping seems to benefit full term infants also in regions with a relatively low prevalence of iron deficiency anaemia. In Nepal, there is a high anaemia prevalence among children between 6 and 17 months (72-78 %). The objective of the proposed study is to evaluate the effects of delayed and early cord clamping on anaemia (and haemoglobin level) at 8 and 12 months, ferritin at 8 and 12 months, bilirubin at 2-3 days, admission to Neonatal Intensive Care Unit (NICU) or special care nursery, and development at 12 and 18-24 months of age. A randomized, controlled trial comparing delayed and early cord clamping will be implemented at Paropakar Maternity and Women's Hospital in Kathmandu, Nepal. Pregnant woman of gestational age 34-41 weeks who deliver vaginally will be included in the study. The interventions will consist of delayed clamping of the umbilical cord (≥180 s after delivery) or early clamping of the umbilical cord (≤60 s). At 8 and 12 months of age, infant's iron status and developmental milestones will be measured. This trial is important to perform because, although strong indications for the beneficial effect of delayed cord clamping on anaemia at 8 to 12 months of age exist, it has not yet been evaluated by a randomized trial in this setting. The proposed study will analyse both outcome as well as safety effects. Additionally, the results may not only contribute to practice in Nepal, but also to the global community, in particular to other low-income countries with a high prevalence of iron deficiency anaemia. Clinical trial.gov NCT02222805 . Registered August 19 2014.
Ye, Q; Heck, G L; DeSimone, J A
1993-07-01
1. Voltage-clamp and current-clamp data were obtained from a circumscribed region of the anterior rat lingual epithelium while simultaneously monitoring the afferent, stimulus-evoked, neural response from the same receptive field. 2. Chorda tympani (CT) responses at constant Na(+)-salt concentration were enhanced by submucosa negative voltage clamp and suppressed by positive voltage clamp. The complete CT response profile, including the time course of adaptation, was not uniquely determined by NaCl concentration alone. The response could be reproduced at different NaCl concentrations by applying a compensating voltage. 3. The form of the concentration and voltage dependence of the CT response indicates that the complete stimulus energy is the Na+ electrochemical potential difference across receptor cell apical membranes, and not Na+ concentration alone. This is the underlying principal behind the equivalence of chemical and electric taste for Na+ salts. 4. CT responses to sodium gluconate (25 and 200 mM) and 25 mM NaCl produced amiloride-insensitive components (AIC) of low magnitude. NaCl at 200 mM produced a significantly larger AIC. The AIC was voltage-clamp independent. The relative magnitude of the AIC was positively correlated with the transepithelial conductance of each salt. This suggests that the large AIC for 200 mM NaCl results from its relatively high permeability through the paracellular pathway. 5. Analysis of the CT response under voltage clamp revealed two anion effects on Na(+)-salt taste, both of which act through the paracellular shunt. 1) Anions modify the transepithelial potential (TP) across tight junctions and thereby modulate the cell receptor potential. This anion effect can be eliminated by voltage clamping the TP. 2) Sufficiently mobile anions facilitate electroneutral diffusion of Na+ salts through tight junctions. This effect is observed especially when Cl- is the anion and when the stimulus concentration favors NaCl influx, allowing Na+ to stimulate receptor cells from the submucosal side. Because the submucosal intercellular spaces are nearly isopotential regions, this effect is insensitive to voltage clamp of the TP. The large AIC associated with this anion effect is due to the low permeability of amiloride.
Time delay compensation for closed-loop insulin delivery systems: a simulation study.
Reboldi, G P; Home, P D; Calabrese, G; Fabietti, P G; Brunetti, P; Massi Benedetti, M
1991-06-01
Closed loop insulin therapy certainly represents the best possible approach to insulin replacement. However, present limitations preclude wider application of the so-called artificial pancreas. Therefore, a thorough understanding of these limitations is needed to design better systems for future long-term use. The present simulation study was design: to obtain better information on the impact of the measurement delay of currently available closed-loop devices both during closed-loop insulin delivery and blood glucose clamp studies, and to design and test a time delay compensator based on the method originally described by O.J. Smith. Simulations were performed on a Compaq Deskpro 486/25 personal computer under MS-DOS operating system using Simnon rel. 3.00 software. There was a direct relationship between measurement delay and amount of insulin delivered, i.e., the longer the delay the higher the insulin dose needed to control a rise in blood glucose; the closed-loop response in presence of a time delay was qualitatively impaired both during insulin delivery and blood glucose clamp studies; time delay compensation was effective in reducing the insulin dose and improving controller stability during the early phase of clamp studies. However, the robustness of a Smith's predictor-based controller should be carefully evaluated before implementation in closed-loop systems can be considered.
Lifting clamp positively grips structural shapes
NASA Technical Reports Server (NTRS)
Reinhardt, E. C.
1966-01-01
Welded steel clamps securely grip structural shapes of various sizes for crane operations. The clamp has adjustable clamping jaws and screw-operated internal v-jaws and provides greater safety than hoisting slings presently used. The structural member can be rotated in any manner, angle, or direction without being released by the clamp.
Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures.
Chamandi, Chekrallah; Puri, Rishi; Rodriguez-Gabella, Tania; Rodés-Cabau, Josep
2017-09-01
Transcatheter aortic valve replacement (TAVR) is a well-established treatment for patients with severe symptomatic aortic stenosis who are at high or prohibitive surgical risk. More recently, TAVR has emerged as a valid alternative to surgical aortic valve replacement for treating intermediate-risk patients, and several studies are currently evaluating the role of TAVR in low-risk patients. Transcatheter heart valve (THV) technologies have evolved considerably over time, and important iterations have been implemented in many of the latest-generation devices to (1) reduce the size and improve delivery system properties; (2) improve valve deployment, repositioning, and retrievability; and (3) reduce paravalvular leaks. This article reviews the main characteristics of, and clinical results associated with, the newer-generation THVs while providing an overview of novel TAVR indications. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine
2018-03-08
Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid aortic valve-ascending thoracic aortic aneurysm 99th-percentile circumferential stresses were 548 kPa versus 462 kPa (P = .033) for tricuspid aortic valve-ascending thoracic aortic aneurysms, which also did not correlate to bicuspid aortic valve-ascending thoracic aortic aneurysm diameter (r = 0.007). Circumferential and longitudinal stresses were greater in bicuspid aortic valve- than tricuspid aortic valve-ascending thoracic aortic aneurysms and were more pronounced in the sinotubular junction. Peak wall stress did not correlate with bicuspid aortic valve-ascending thoracic aortic aneurysm diameter, suggesting diameter alone in this population may be a poor predictor of dissection risk. Our results highlight the need for patient-specific aneurysm wall stress analysis for accurate dissection risk prediction. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...
Dankerl, Peter; Hammon, Matthias; Seuss, Hannes; Tröbs, Monique; Schuhbaeck, Annika; Hell, Michaela M; Cavallaro, Alexander; Achenbach, Stephan; Uder, Michael; Marwan, Mohamed
2017-05-01
To evaluate the performance of computer-aided evaluation software for a comprehensive workup of patients prior to transcatheter aortic valve implantation (TAVI) using low-contrast agent and low radiation dose third-generation dual-source CT angiography. We evaluated 30 consecutive patients scheduled for TAVI. All patients underwent ECG-triggered high-pitch dual-source CT angiography of the aortic root and aorta with a standardized contrast agent volume (30 ml Imeron350, flow rate 4 ml/s) and low-dose (100 kv/350 mAs) protocol. An expert (10 years of experience) manually evaluated aortic root and iliac access dimensions (distance between coronary ostia and aortic annulus, minimal/maximal diameters and area-derived diameter of the aortic annulus) and best CT-predicted fluoroscopic projection angle as the reference standard. Utilizing computer-aided software (syngo.via), the same pre-TAVI workup was performed and compared to the reference standard. Mean CTDI[Formula: see text] was 3.46 mGy and mean DLP 217.6 ± 12.1 mGy cm, corresponding to a mean effective dose of 3.7 ± 0.2 mSv. Computer-aided evaluation was successful in all but one patient. Compared to the reference standard, Bland-Altman analysis indicated very good agreement for the distances between aortic annulus and coronary ostia (RCA: mean difference 0.8 mm; 95 % CI 0.4-1.2 mm; LM: mean difference 0.9 mm; 95 % CI 0.5-1.3 mm); however, we demonstrated a systematic overestimation of annulus- derived diameter using the software (mean difference 44.4 mm[Formula: see text]; 95 % CI 30.4-58.3 mm[Formula: see text]). Based on respective annulus dimensions, the recommended prosthesis size (Edwards SAPIEN 3) matched in 26 out of the 29 patients (90 %). CT-derived fluoroscopic projection angles showed an excellent agreement for both methods. Out of 58 iliac arteries, 15 (25 %) arteries could not be segmented by the software. Preprocessing time of the software was 71 ± 11 s (range 51-96 s), and reading time with the software was 118 ± 31 s (range 68-201 s). In the workup of pre-TAVI CT angiography, computer-aided evaluation of low-contrast, low-dose examinations is feasible with good agreement and quick reading time. However, a systematic overestimation of the aortic annulus area is observed.
Preparation of Drosophila central neurons for in situ patch clamping.
Ryglewski, Stefanie; Duch, Carsten
2012-10-15
Short generation times and facile genetic techniques make the fruit fly Drosophila melanogaster an excellent genetic model in fundamental neuroscience research. Ion channels are the basis of all behavior since they mediate neuronal excitability. The first voltage gated ion channel cloned was the Drosophila voltage gated potassium channel Shaker(1,2). Toward understanding the role of ion channels and membrane excitability for nervous system function it is useful to combine powerful genetic tools available in Drosophila with in situ patch clamp recordings. For many years such recordings have been hampered by the small size of the Drosophila CNS. Furthermore, a robust sheath made of glia and collagen constituted obstacles for patch pipette access to central neurons. Removal of this sheath is a necessary precondition for patch clamp recordings from any neuron in the adult Drosophila CNS. In recent years scientists have been able to conduct in situ patch clamp recordings from neurons in the adult brain(3,4) and ventral nerve cord of embryonic(5,6), larval(7,8,9,10), and adult Drosophila(11,12,13,14). A stable giga-seal is the main precondition for a good patch and depends on clean contact of the patch pipette with the cell membrane to avoid leak currents. Therefore, for whole cell in situ patch clamp recordings from adult Drosophila neurons must be cleaned thoroughly. In the first step, the ganglionic sheath has to be treated enzymatically and mechanically removed to make the target cells accessible. In the second step, the cell membrane has to be polished so that no layer of glia, collagen or other material may disturb giga-seal formation. This article describes how to prepare an identified central neuron in the Drosophila ventral nerve cord, the flight motoneuron 5 (MN5(15)), for somatic whole cell patch clamp recordings. Identification and visibility of the neuron is achieved by targeted expression of GFP in MN5. We do not aim to explain the patch clamp technique itself.
Semaan, Edouard; Markl, Michael; Chris Malaisrie, S.; Barker, Alex; Allen, Bradley; McCarthy, Patrick; Carr, James C.; Collins, Jeremy D.
2014-01-01
OBJECTIVE To provide a more complete characterization of aortic blood flow in patients following valve-sparing aortic root replacement (VSARR) compared with presurgical cohorts matched by tricuspid and bicuspid valve morphology, age and presurgical aorta size. METHODS Four-dimensional (4D) flow magnetic resonance imaging (MRI) was performed to analyse three-dimensional (3D) blood flow in the thoracic aorta of n = 13 patients after VSARR with reimplantation of native tricuspid aortic valve (TAV, n = 6) and bicuspid aortic valve (BAV, n = 7). Results were compared with presurgical age and aortic size-matched control cohorts with TAV (n = 10) and BAV (n = 10). Pre- and post-surgical aortic flow was evaluated using time-resolved 3D pathlines using a blinded grading system (0–2, 0 = small, 1 = moderate and 2 = prominent) analysing ascending aortic (AAo) helical flow. Systolic flow profile uniformity in the aortic root, proximal and mid-AAo was evaluated using a four-quadrant model. Further analysis in nine analysis planes distributed along the thoracic aorta quantified peak systolic velocity, retrograde fraction and peak systolic flow acceleration. RESULTS Pronounced AAo helical flow in presurgical control subjects (both BAV and TAV: helix grading = 1.8 ± 0.4) was significantly reduced (0.2 ± 0.4, P < 0.001) in cohorts after VSARR independent of aortic valve morphology. Presurgical AAo flow was highly eccentric for BAV patients but more uniform for TAV. VSARR resulted in less eccentric flow profiles. Systolic peak velocities were significantly (P < 0.05) increased in post-root repair BAV patients throughout the aorta (six of nine analysis planes) and to a lesser extent in TAV patients (three of nine analysis planes). BAV reimplantation resulted in significantly increased peak velocities in the proximal AAo compared with root repair with TAV (2.3 ± 0.6 vs 1.6 ± 0.4 m/s, P = 0.017). Post-surgical patients showed a non-significant trend towards higher systolic flow acceleration as a surrogate measure of reduced aortic compliance. CONCLUSIONS VSARR restored a cohesive flow pattern independent of native valve morphology but resulted in increased peak velocities throughout the aorta. 4D flow MRI methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing VSARR. PMID:24317086
2D to 3D fusion of echocardiography and cardiac CT for TAVR and TAVI image guidance.
Khalil, Azira; Faisal, Amir; Lai, Khin Wee; Ng, Siew Cheok; Liew, Yih Miin
2017-08-01
This study proposed a registration framework to fuse 2D echocardiography images of the aortic valve with preoperative cardiac CT volume. The registration facilitates the fusion of CT and echocardiography to aid the diagnosis of aortic valve diseases and provide surgical guidance during transcatheter aortic valve replacement and implantation. The image registration framework consists of two major steps: temporal synchronization and spatial registration. Temporal synchronization allows time stamping of echocardiography time series data to identify frames that are at similar cardiac phase as the CT volume. Spatial registration is an intensity-based normalized mutual information method applied with pattern search optimization algorithm to produce an interpolated cardiac CT image that matches the echocardiography image. Our proposed registration method has been applied on the short-axis "Mercedes Benz" sign view of the aortic valve and long-axis parasternal view of echocardiography images from ten patients. The accuracy of our fully automated registration method was 0.81 ± 0.08 and 1.30 ± 0.13 mm in terms of Dice coefficient and Hausdorff distance for short-axis aortic valve view registration, whereas for long-axis parasternal view registration it was 0.79 ± 0.02 and 1.19 ± 0.11 mm, respectively. This accuracy is comparable to gold standard manual registration by expert. There was no significant difference in aortic annulus diameter measurement between the automatically and manually registered CT images. Without the use of optical tracking, we have shown the applicability of this technique for effective fusion of echocardiography with preoperative CT volume to potentially facilitate catheter-based surgery.
Eide, Leslie S P; Ranhoff, Anette H; Fridlund, Bengt; Haaverstad, Rune; Hufthammer, Karl Ove; Kuiper, Karel K J; Nordrehaug, Jan Erik; Norekvål, Tone M
2015-03-15
Postoperative delirium (PD) after transcatheter aortic valve implantation (TAVI) remains to be explored. We sought to (1) determine the incidence of PD in octogenarians who underwent TAVI or surgical aortic valve replacement (SAVR), (2) identify its risk factors, and (3) describe possible differences in the onset and course of PD between treatment groups. A prospective cohort study of consecutive patients aged ≥80 years with severe aortic stenosis who underwent elective TAVI or SAVR (N = 143) was conducted. The incidence of PD was assessed for 5 days using the Confusion Assessment Method (CAM). Risk factors for PD were studied with logistic regression. Patients treated with TAVI were older (p ≤0.001), had lower cognitive scores (p = 0.007), and more co-morbidities (p = 0.003). Despite this, significantly fewer (p = 0.013) patients treated with TAVI (44%) experienced PD compared to patients treated with SAVR (66%). Undergoing SAVR (p = 0.02) and having lower cognitive function (p = 0.03) emerged as risk factors for PD, whereas gender, activities of daily living, frailty, atrial fibrillation, and postoperative use of opioids and anxiolytics did not. Patients treated with TAVI and without PD during the first 2 postoperative days were unlikely to experience PD on subsequent days. The onset of PD after SAVR could occur at any time during the postoperative evaluation. In conclusion, SAVR in octogenarian patients with aortic stenosis might be considered as a predisposing factor for PD. Our data also suggest that the onset of PD was more unpredictable after SAVR. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Faletti, Riccardo; Gatti, Marco; Cosentino, Aurelio; Bergamasco, Laura; Cura Stura, Erik; Garabello, Domenica; Pennisi, Giovanni; Salizzoni, Stefano; Veglia, Simona; Ottavio, Davini; Rinaldi, Mauro; Fonio, Paolo
2018-05-26
to determine reliability and reproducibility of measurements of aortic annulus in 3D models printed from cardiovascular computed tomography (CCT) images. Retrospective study on the records of 20 patients who underwent aortic valve replacement (AVR) with pre-surgery annulus assessment by CCT and intra-operative sizing by Hegar dilators (IOS). 3D models were fabricated by fused deposition modelling of thermoplastic polyurethane filaments. For each patient, two 3D models were independently segmented, modelled and printed by two blinded "manufacturers": a radiologist and a radiology technician. Two blinded cardiac surgeons performed the annulus diameter measurements by Hegar dilators on the two sets of models. Matched data from different measurements were analyzed with Wilcoxon test, Bland-Altmann plot and within-subject ANOVA. No significant differences were found among the measurements made by each cardiac surgeon on the same 3D model (p = 0.48) or on the 3D models printed by different manufacturers (p = 0.25); also, no intraobserver variability (p = 0.46). The annulus diameter measured on 3D models showed good agreement with the reference CCT measurement (p = 0.68) and IOH sizing (p = 0.11). Time and cost per model were: model creation ∼10-15 min; printing time ∼60 min; post-processing ∼5min; material cost ∼1€. CONCLUSION: 3D printing of aortic annulus can offer reliable, not expensive patient-specific information to be used in the pre-operative planning of AVR or transcatheter aortic valve implantation (TAVI). Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
To compare beta-cell function relative to insulin sensitivity, disposition index (DI), calculated from two clamps (2cDI, insulin sensitivity from the hyperinsulinemic-euglycemic clamp and first-phase insulin from the hyperglycemic clamp) with the DI calculated from the hyperglycemic clamp alone (hcD...
21 CFR 882.4460 - Neurosurgical head holder (skull clamp).
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...
Ibrahim, Michael; Kukadia, Punam; Siedlecka, Urszula; Cartledge, James E; Navaratnarajah, Manoraj; Tokar, Sergiy; Van Doorn, Carin; Tsang, Victor T; Gorelik, Julia; Yacoub, Magdi H; Terracciano, Cesare M
2012-12-01
Cardiac transverse (t)-tubules are altered during disease and may be regulated by stretch-sensitive molecules. The relationship between variations in the degree and duration of load and t-tubule structure remains unknown, as well as its implications for local Ca(2+)-induced Ca(2+) release (CICR). Rat hearts were studied after 4 or 8 weeks of moderate mechanical unloading [using heterotopic abdominal heart-lung transplantation (HAHLT)] and 6 or 10 weeks of pressure overloading using thoracic aortic constriction. CICR, cell and t-tubule structure were assessed using confocal-microscopy, patch-clamping and scanning ion conductance microscopy. Moderate unloading was compared with severe unloading [using heart-only transplantation (HAHT)]. Mechanical unloading reduced cardiomyocyte volume in a time-dependent manner. Ca(2+) release synchronicity was reduced at 8 weeks moderate unloading only. Ca(2+) sparks increased in frequency and duration at 8 weeks of moderate unloading, which also induced t-tubule disorganization. Overloading increased cardiomyocyte volume and disrupted t-tubule morphology at 10 weeks but not 6 weeks. Moderate mechanical unloading for 4 weeks had milder effects compared with severe mechanical unloading (37% reduction in cell volume at 4 weeks compared to 56% reduction after severe mechanical unloading) and did not cause depression and delay of the Ca(2+) transient, increased Ca(2+) spark frequency or impaired t-tubule and cell surface structure. These data suggest that variations in chronic mechanical load influence local CICR and t-tubule structure in a time- and degree-dependent manner, and that physiological states of increased and reduced cell size, without pathological changes are possible. © 2012 The Authors Journal of Cellular and Molecular Medicine © 2012 Foundation for Cellular and Molecular Medicine/Blackwell Publishing Ltd.
Initial Experience With a New Mitral Ring Designed to Simplify Length Determination of Neochords.
Prinzing, Anatol; Bleiziffer, Sabine; Krane, Markus; Lange, Ruediger
2018-06-01
Artificial chord implantation has become one of the most applied techniques for mitral valve repair (MVR). Many techniques have been described, with the goal of optimizing neochord implantation. A new annuloplasty device designed to simplify the determination of the appropriate neochord length has been recently introduced. We describe our initial experience with this new device. The semirigid device is equipped with removable loops on the posterior aspect of the ring. Neochords are tied to the loops, which are subsequently removed. The device was implanted in 47 symptomatic patients from January 2015 to August 2016 through a median sternotomy in 33 patients (70.2%) and a right anterolateral minithoracotomy in 14 (29.8%). The cause of mitral valve insufficiency was degenerative in all patients, and most patients presented with isolated prolapse of the posterior leaflet. Before and after cardiopulmonary bypass, all patients underwent evaluation with transesophageal echocardiography, and transthoracic echocardiography was performed at discharge. A median of 2 neochords were implanted (minimum, 1; maximum, 6). Mean cardiopulmonary bypass time and aortic cross-clamp times were 141.7 ± 32.3 and 104.8 ± 28.5 minutes for combined and 133 ± 53.9 and 98.3 ± 41.6 minutes for isolated MVR. At discharge, echocardiography revealed no or only mild mitral insufficiency in 45 patients (mean gradient, 2.9 ± 1.3 mm Hg). This new annuloplasty ring facilitated determination of appropriate neochord length and was used to successfully treat different degenerative pathologies affecting both leaflets. This new device simplified length determination of the neochords. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ostrowsky, Jacob; Foes, Jennifer; Warchol, Mark; Tsarovsky, Gary; Blay, Jessica
2004-06-01
Approximately 3.5 million units of platelets are transfused in the United States each year to patients undergoing open-heart surgery with cardiopulmonary bypass (CPB). CPB is a known contributor to platelet loss and platelet dysfunction leading to disruption of hemostasis. Impaired hemostasis results in excess bleeding in 5-25% of all patients undergoing CPB. For this reason, it may be beneficial to measure platelet number and function in these patients. The purpose of this study was to compare the Plateletworks platelet function analyzer to the thromboelastograph (TEG) in predicting postoperatiave hemostatic outcomes as measured by blood product use and chest tube (CT) drainage. This study consisted of 35 adult patients undergoing cardiac surgery with cardiopulmonary bypass at Rush-Presbyterian-Saint Luke's Medical Center (RPSLMC). The Plateletworks and TEG tests were performed preoperatively, after protamine was given, and 24 hours postoperatively on all patients. Plateletworks demonstrated a statistically significant change in platelet function as shown by the adenosine diphosphate (ADP) reagent tube from the preoperative period to the removal of the aortic cross clamp (p = .011). The TEG did not demonstrate a significant change in the k-time and maximum amplitude (MA), but did show a significant change in the alpha-angle from the pre-operative to postoperatiave sample (p = .035). A correlation was found between Plateletworks collagen reagent tubes preoperatively and CT drainage (p = .048, r -0.324). No statistical correlation was established between TEG parameters and CT drainage at any time interval. TEG preoperative MA showed a correlation to receipt of blood products (p = .016). When comparing the Plateletworks to the TEG in this study, the Plateletworks system was a more useful predictor of blood product use and chest tube drainage.
Sharma, V; Katznelson, R; Jerath, A; Garrido-Olivares, L; Carroll, J; Rao, V; Wasowicz, M; Djaiani, G
2014-02-01
Because of a lack of contemporary data regarding seizures after cardiac surgery, we undertook a retrospective analysis of prospectively collected data from 11 529 patients in whom cardiopulmonary bypass was used from January 2004 to December 2010. A convulsive seizure was defined as a transient episode of disturbed brain function characterised by abnormal involuntary motor movements. Multivariate regression analysis was performed to identify independent predictors of postoperative seizures. A total of 100 (0.9%) patients developed postoperative convulsive seizures. Generalised and focal seizures were identified in 68 and 32 patients, respectively. The median (IQR [range]) time after surgery when the seizure occurred was 7 (6-12 [1-216]) h and 8 (6-11 [4-18]) h, respectively. Epileptiform findings on electroencephalography were seen in 19 patients. Independent predictors of postoperative seizures included age, female sex, redo cardiac surgery, calcification of ascending aorta, congestive heart failure, deep hypothermic circulatory arrest, duration of aortic cross-clamp and tranexamic acid. When tested in a multivariate regression analysis, tranexamic acid was a strong independent predictor of seizures (OR 14.3, 95% CI 5.5-36.7; p < 0.001). Patients with convulsive seizures had 2.5 times higher in-hospital mortality rates and twice the length of hospital stay compared with patients without convulsive seizures. Mean (IQR [range]) length of stay in the intensive care unit was 115 (49-228 [32-481]) h in patients with convulsive seizures compared with 26 (22-69 [14-1080]) h in patients without seizures (p < 0.001). Convulsive seizures are a serious postoperative complication after cardiac surgery. As tranexamic acid is the only modifiable factor, its administration, particularly in doses exceeding 80 mg.kg(-1), should be weighed against the risk of postoperative seizures.
Pathogenetic Basis of Aortopathy and Aortic Valve Disease
2018-02-19
Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome
Hybrid treatment of aortic arch disease
Metzger, Patrick Bastos; Rossi, Fabio Henrique; Moreira, Samuel Martins; Issa, Mario; Izukawa, Nilo Mitsuru; Dinkhuysen, Jarbas J.; Spina Neto, Domingos; Kambara, Antônio Massamitsu
2014-01-01
Introduction The management of thoracic aortic disease involving the ascending aorta, aortic arch and descending thoracic aorta are technically challenging and is an area in constant development and innovation. Objective To analyze early and midterm results of hybrid treatment of arch aortic disease. Methods Retrospective study of procedures performed from January 2010 to December 2012. The end points were the technical success, therapeutic success, morbidity and mortality, neurologic outcomes, the rate of endoleaks and reinterventions. Results A total of 95 patients treated for thoracic aortic diseases in this period, 18 underwent hybrid treatment and entered in this study. The average ages were 62.3 years. The male was present in 66.7%. The technical and therapeutic success was 94.5% e 83.3%. The perioperative mortality rate of 11.1%. There is any death during one-year follow- up. The reoperation rates were 16.6% due 2 cases of endoleak Ia and one case of endoleak II. There is any occlusion of anatomic or extra anatomic bypass during follow up. Conclusion In our study, the hybrid treatment of aortic arch disease proved to be a feasible alternative of conventional surgery. The therapeutic success rates and re- interventions obtained demonstrate the necessity of thorough clinical follow-up of these patients in a long time. PMID:25714205
NASA Astrophysics Data System (ADS)
Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto
2016-11-01
Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented
Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.
Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F
1983-09-01
Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.
Wendell, David C.; Samyn, Margaret M.; Cava, Joseph R.; Ellwein, Laura M.; Krolikowski, Mary M.; Gandy, Kimberly L.; Pelech, Andrew N.; Shadden, Shawn C.; LaDisa, John F.
2012-01-01
Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to develop a method to account for the AoV in CFD simulations, and quantify its impact on local hemodynamics. The method developed facilitates segmentation of the AoV, spatiotemporal interpolation of segments, and anatomic positioning of segments at the CFD model inlet. The AoV was included in CFD model examples of a normal (tricuspid AoV) and a post-surgical CoA patient (BAV). Velocity, turbulent kinetic energy (TKE), time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) results were compared to equivalent simulations using a plug inlet profile. The plug inlet greatly underestimated TKE for both examples. TAWSS differences extended throughout the thoracic aorta for the CoA BAV, but were limited to the arch for the normal example. OSI differences existed mainly in the ascending aorta for both cases. The impact of AoV can now be included with CFD simulations to identify regions of deleterious hemodynamics thereby advancing simulations of the thoracic aorta one step closer to reality. PMID:22917990
Sripathi, Vangipuram Canchi; Kumar, Ramarathnam Krishna; Balakrishnan, Komarakshi R
2004-03-01
This study aims to find the fundamental differences in the mechanism of opening and closing of a normal aortic valve and a valve with a stiff root, using a dynamic finite element model. A dynamic, finite element model with time varying pressure was used in this study. Shell elements with linear elastic properties for the leaflet and root were used. Two different cases were analyzed: (1) normal leaflets inside a compliant root, and (2) normal leaflets inside a stiff root. A compliant aortic root contributes substantially to the smooth and symmetrical leaflet opening with minimal gradients. In contrast, the leaflet opening inside a stiff root is delayed, asymmetric, and wrinkled. However, this wrinkling is not associated with increased leaflet stresses. In compliant roots, the effective valve orifice area can substantially increase because of increased root pressure and transvalvular gradients. In stiff roots this effect is strikingly absent. A compliant aortic root contributes substantially to smooth and symmetrical leaflet opening with minimal gradients. The compliance also contributes much to the ability of the normal aortic valve to increase its effective valve orifice in response to physiologic demands of exercise. This effect is strikingly absent in stiff roots.
Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording
Kolb, Ilya; Kodandaramaiah, Suhasa B.; Chubykin, Alexander A.; Yang, Aimei; Bear, Mark F.; Boyden, Edward S.; Forest, Craig R.
2014-01-01
Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput of patch clamping for single-ion channel and single-cell analyses. In this work, we have developed a custom patch-clamp amplifier microchip that can be fabricated using standard commercial silicon processes capable of performing both voltage- and current-clamp measurements. A key innovation is the use of nonlinear feedback elements in the voltage-clamp amplifier circuit to convert measured currents into logarithmically encoded voltages, thereby eliminating the need for large high-valued resistors, a factor that has limited previous attempts at integration. Benchtop characterization of the chip shows low levels of current noise [1.1 pA root mean square (rms) over 5 kHz] during voltage-clamp measurements and low levels of voltage noise (8.2 μV rms over 10 kHz) during current-clamp measurements. We demonstrate the ability of the chip to perform both current- and voltage-clamp measurement in vitro in HEK293FT cells and cultured neurons. We also demonstrate its ability to perform in vivo recordings as part of a robotic patch-clamping system. The performance of the patch-clamp amplifier microchip compares favorably with much larger commercial instrumentation, enabling benchtop commoditization, miniaturization, and scalable patch-clamp instrumentation. PMID:25429119
Mittan, Margaret Birmingham [Oakland, CA; Miros, Robert H. J. [Fairfax, CA; Brown, Malcolm P [San Francisco, CA; Stancel, Robert [Loss Altos Hills, CA
2012-06-05
A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.
Brown, Malcolm P.; Mittan, Margaret Birmingham; Miros, Robert H. J.; Stancel, Robert
2013-03-19
A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.
Li, Xin; Zhang, Hong-Yu; Han, Feng-Zhen; Yu, Chang-Jiang; Fan, Xiao-Ping; Fan, Rui-Xin; Zhuang, Jian
2017-11-20
To explore the diagnosis and treatment of pregnancy-associated acute Stanford type A aortic dissection to improve the maternal and fetal outcomes. We analyzed the perioperative data of 5 pregnant women with acute Stanford type A aortic dissection treated between June, 2009 and February, 2017. The median age of the women was 30 years (range, 22-34 years) with gestational weeks of 23-38 weeks upon diagnosis. All the 5 patients received surgical interventions. Three patients underwent caesarean delivery and hysterectomy, and the fetuses survived after the surgery; 2 patients chose to continue pregnancy following the surgery, among whom one died due to postoperative complications and the other underwent termination of pregnancy. During follow-up, the surviving patients showed no endoleak in the descending aorta stent and the distal dissection remained stable. The maternal and fetal outcomes of pregnancy-associated acute Stanford type A aortic dissection can be improved by multidisciplinary cooperation and optimization of the surgical approaches according to the time of pregnancy, fetal development and conditions of the aortic lesions.
Automatic aortic root segmentation in CTA whole-body dataset
NASA Astrophysics Data System (ADS)
Gao, Xinpei; Kitslaar, Pieter H.; Scholte, Arthur J. H. A.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Reiber, Johan H. C.
2016-03-01
Trans-catheter aortic valve replacement (TAVR) is an evolving technique for patients with serious aortic stenosis disease. Typically, in this application a CTA data set is obtained of the patient's arterial system from the subclavian artery to the femoral arteries, to evaluate the quality of the vascular access route and analyze the aortic root to determine if and which prosthesis should be used. In this paper, we concentrate on the automated segmentation of the aortic root. The purpose of this study was to automatically segment the aortic root in computed tomography angiography (CTA) datasets to support TAVR procedures. The method in this study includes 4 major steps. First, the patient's cardiac CTA image was resampled to reduce the computation time. Next, the cardiac CTA image was segmented using an atlas-based approach. The most similar atlas was selected from a total of 8 atlases based on its image similarity to the input CTA image. Third, the aortic root segmentation from the previous step was transferred to the patient's whole-body CTA image by affine registration and refined in the fourth step using a deformable subdivision surface model fitting procedure based on image intensity. The pipeline was applied to 20 patients. The ground truth was created by an analyst who semi-automatically corrected the contours of the automatic method, where necessary. The average Dice similarity index between the segmentations of the automatic method and the ground truth was found to be 0.965±0.024. In conclusion, the current results are very promising.
Dale, Matthew A; Xiong, Wanfen; Carson, Jeffrey S; Suh, Melissa K; Karpisek, Andrew D.; Meisinger, Trevor M.; Casale, George P.; Baxter, B. Timothy
2016-01-01
Abdominal aortic aneurysm (AAA) is a dynamic vascular disease characterized by inflammatory cell invasion and extracellular matrix (ECM) degradation. Damage to elastin in the ECM results in release of elastin-derived peptides (EDPs), which are chemotactic for inflammatory cells such as monocytes. Their effect on macrophage polarization is less well known. Pro-inflammatory M1 macrophages initially are recruited to sites of injury but, if their effects are prolonged, they can lead to chronic inflammation that prevents normal tissue repair. Conversely, anti-inflammatory M2 macrophages reduce inflammation and aid in wound healing. Thus, a proper M1/M2 ratio is vital for tissue homeostasis. AAA tissue reveals a high M1/M2 ratio where pro-inflammatory cells and their associated markers dominate. In the present study, in vitro treatment of bone marrow-derived macrophages with EDPs induced M1 macrophage polarization. By using C57Bl/6 mice, antibody-mediated neutralization of EDPs reduced aortic dilation, matrix metalloproteinase activity, and pro-inflammatory cytokine expression at early and late time points after aneurysm induction. Furthermore, direct manipulation of the M1/M2 balance altered aortic dilation. Injection of M2 polarized macrophages reduced aortic dilation after aneurysm induction. EDPs promoted a pro-inflammatory environment in aortic tissue by inducing M1 polarization and neutralization of EDPs attenuated aortic dilation. The M1/M2 imbalance is vital to aneurysm formation. PMID:27183603
Scharfschwerdt, Michael; Leonhard, Moritz; Lehmann, Judith; Richardt, Doreen; Goldmann, Helmut; Sievers, Hans-Hinrich
2016-05-01
Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular prosthesis providing elastic behaviours. In a first series (n = 14), haemodynamics and leaflet motions of the aortic valve were investigated and also cyclic changes of aortic dimensions at different levels of the root. In a second series (n = 7), intravascular pressure and dimensions of the proximal descending aorta were measured and the corresponding wall tension was calculated. Haemodynamics of the aortic valve remain comparable after replacement. Though the novel prosthesis does not feature such high distensibility as the native aorta, the dynamic of the root was significantly increased compared with common Dacron prostheses at the commissural level, preserving 'windkessel' function. Thus, wall tension of the residual aorta remained unchanged; nevertheless, maximum pressure-time differential dp/dt increased by 13%. The use of the novel elastic prosthesis for replacement of the ascending aorta seems to be beneficial, especially with regard to the preservation of the aortic windkessel. Further studies will be needed to clarify long-term utilization of the material in vivo. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Brecker, Stephen; Mealing, Stuart; Padhiar, Amie; Eaton, James; Sculpher, Mark; Busca, Rachele; Bosmans, Johan; Gerckens, Ulrich J; Wenaweser, Peter; Tamburino, Corrado; Bleiziffer, Sabine; Piazza, Nicolo; Moat, Neil; Linke, Axel
2014-01-01
Objective To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK NHS. Methods A published decision-analytic model was adapted to include information on TAVI from the ADVANCE study. Patient-level data informed the choice as well as the form of mathematical functions that were used to model all-cause mortality, health-related quality of life and hospitalisations. TAVI-related resource use protocols were based on the ADVANCE study. MM was modelled on publicly available information from the PARTNER-B study. The outcome measures were incremental cost-effectiveness ratios (ICERs) estimated at a range of time horizons with benefits expressed as quality-adjusted life-years (QALY). Extensive sensitivity/subgroup analyses were undertaken to explore the impact of uncertainty in key clinical areas. Results Using a 5-year time horizon, the ICER for the comparison of all ADVANCE to all PARTNER-B patients was £13 943 per QALY gained. For the subset of ADVANCE patients classified as high risk (Logistic EuroSCORE >20%) the ICER was £17 718 per QALY gained). The ICER was below £30 000 per QALY gained in all sensitivity analyses relating to choice of MM data source and alternative modelling approaches for key parameters. When the time horizon was extended to 10 years, all ICERs generated in all analyses were below £20 000 per QALY gained. Conclusion TAVI is highly likely to be a cost-effective treatment for patients with severe aortic stenosis. PMID:25349700
Brecker, Stephen; Mealing, Stuart; Padhiar, Amie; Eaton, James; Sculpher, Mark; Busca, Rachele; Bosmans, Johan; Gerckens, Ulrich J; Wenaweser, Peter; Tamburino, Corrado; Bleiziffer, Sabine; Piazza, Nicolo; Moat, Neil; Linke, Axel
2014-01-01
To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK NHS. A published decision-analytic model was adapted to include information on TAVI from the ADVANCE study. Patient-level data informed the choice as well as the form of mathematical functions that were used to model all-cause mortality, health-related quality of life and hospitalisations. TAVI-related resource use protocols were based on the ADVANCE study. MM was modelled on publicly available information from the PARTNER-B study. The outcome measures were incremental cost-effectiveness ratios (ICERs) estimated at a range of time horizons with benefits expressed as quality-adjusted life-years (QALY). Extensive sensitivity/subgroup analyses were undertaken to explore the impact of uncertainty in key clinical areas. Using a 5-year time horizon, the ICER for the comparison of all ADVANCE to all PARTNER-B patients was £13 943 per QALY gained. For the subset of ADVANCE patients classified as high risk (Logistic EuroSCORE >20%) the ICER was £17 718 per QALY gained). The ICER was below £30 000 per QALY gained in all sensitivity analyses relating to choice of MM data source and alternative modelling approaches for key parameters. When the time horizon was extended to 10 years, all ICERs generated in all analyses were below £20 000 per QALY gained. TAVI is highly likely to be a cost-effective treatment for patients with severe aortic stenosis.
High Performance ZVT with Bus Clamping Modulation Technique for Single Phase Full Bridge Inverters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Yinglai; Ayyanar, Raja
2016-03-20
This paper proposes a topology based on bus clamping modulation and zero-voltage-transition (ZVT) technique to realize zero-voltage-switching (ZVS) for all the main switches of the full bridge inverters, and inherent ZVS and/or ZCS for the auxiliary switches. The advantages of the strategy include significant reduction in the turn-on loss of the ZVT auxiliary switches which typically account for a major part of the total loss in other ZVT circuits, and reduction in the voltage ratings of auxiliary switches. The modulation scheme and the commutation stages are analyzed in detail. Finally, a 1kW, 500 kHz switching frequency inverter of the proposedmore » topology using SiC MOSFETs has been built to validate the theoretical analysis. The ZVT with bus clamping modulation technique of fixed timing and adaptive timing schemes are implemented in DSP TMS320F28335 resulting in full ZVS for the main switches in the full bridge inverter. The proposed scheme can save up to 33 % of the switching loss compared with no ZVT case.« less
Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K.; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M.; Thirumurthy, Harsha
2015-01-01
Background: Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Methods: Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. Results: The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. Conclusions: EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization. PMID:26017658
Kamiyama, Yoshihiro; Yamashita, Shinichi; Nakagawa, Atsuhiro; Fujii, Shinji; Mitsuzuka, Koji; Kaiho, Yasuhiro; Ito, Akihiro; Abe, Takaaki; Tominaga, Teiji; Arai, Yoichi
2017-09-01
In the setting of partial nephrectomy (PN) for renal cell carcinoma, postoperative renal dysfunction might be caused by surgical procedure. The aim of this study was to clarify the technical safety and renal damage after off-clamp laparoscopic PN (LPN) with a piezo actuator-driven pulsed water jet (ADPJ) system. Eight swine underwent off-clamp LPN with this surgical device, while off-clamp open PN was also performed with radio knife or soft coagulation. The length of the removed kidney was 40 mm, and the renal parenchyma was dissected until the renal calyx became clearly visible. The degree of renal degeneration from the resection surface was compared by Hematoxylin-Eosin staining and immunostaining for 1-methyladenosine, a sensitive marker for the ischemic tissue damage. The mRNA levels of neutrophil gelatinase-associated lipocalin (Ngal), a biomarker for acute kidney injury, were measured by quantitative real-time PCR. Off-clamp LPN with ADPJ system was successfully performed while preserving fine blood vessels and the renal calix with little bleeding. In contrast to other devices, the resection surface obtained with the ADPJ system showed only marginal degree of ischemic changes. Indeed, the expression level of Ngal mRNA was lower in the resection surface obtained with the ADPJ system than that with soft coagulation (p = 0.02). Furthermore, using the excised specimens of renal cell carcinoma, we measured the breaking strength at each site of the human kidney, suggesting the applicability of this ADPJ to clinical trials. In conclusion, off-clamp LPN with the ADPJ system could be safely performed with attenuated renal damage.
Lim, Ju Y; Jung, Sung H; Kim, Joon B; Kim, Dong K; Chung, Cheol H; Song, Hyun; Lee, Jae W; Choo, Suk J
2013-05-01
Concerns of increased surgical risks with ascending aortic replacement have led surgeons to manage post-stenotic aortic dilatation more conservatively during aortic valve replacement (AVR). The present study aimed to assess the prognostic implications and surgical risks of replacing the dilated aorta during AVR. Between January 1999 and March 2010, 134 patients who received surgery for aortic stenosis and post-stenotic dilatation (aorta size ≥40 mm) were included in the present study. AVR was performed in 92 patients (AVR group) while aortic valve and ascending aorta replacement (AVR + aorta group) were performed in 42 patients. Overall survival was compared between the two groups using Cox proportional hazard model after adjustment with inverse-probability-of-treatment weighting. The mean follow-up duration was 3.5 ± 3 years. There were no significant differences in the operative mortality and morbidity between the two groups. The late cardiac deaths were also not significantly different between the two groups (p = 1.00). In the AVR group, the ascending aortic expansion rate which was 0.18 mm/year over a mean follow-up duration of 2.3 ± 2.2 years by echocardiography showed a positive correlation with time (r = 0.3, p = 0.08). A relatively greater aortic expansion rate was identified as a risk factor for late mortality (p = 0.015, HR 1.08 (CI: 1.02 to 1.15). Concomitant replacement of the dilated ascending aorta during AVR did not increase the immediate postoperative morbidity or mortality risks and tended to exert a long-term beneficial effect on the risk of late mortality. © 2013 Wiley Periodicals, Inc.
Kayashima, Yukako; Makhanova, Natalia A.; Matsuki, Kota; Tomita, Hirofumi; Bennett, Brian J.; Maeda, Nobuyo
2015-01-01
The genetic background of apolipoprotein E (apoE) deficient mice influences atherosclerotic plaque development. We previously reported three quantitative trait loci (QTL), Aath1–Aath3, that affect aortic arch atherosclerosis independently of those in the aortic root in a cross between C57BL6 apoEKO mice (B6-apoE) and 129S6 apoEKO mice (129-apoE). To gain further insight into genetic factors that influence atherosclerosis at different vascular locations, we analyzed 335 F2 mice from an intercross between 129-apoE and apoEKO mice on a DBA/2J genetic background (DBA-apoE). The extent of atherosclerosis in the aortic arch was very similar in the two parental strains. Nevertheless, a genome-wide scan identified two significant QTL for plaque size in the aortic arch: Aath4 on Chromosome (Chr) 2 at 137 Mb and Aath5 on Chr 10 at 51 Mb. The DBA alleles of Aath4 and Aath5 respectively confer susceptibility and resistance to aortic arch atherosclerosis over 129 alleles. Both QTL are also independent of those affecting plaque size at the aortic root. Genome analysis suggests that athero-susceptibility of Aath4 in DBA may be contributed by multiple genes, including Mertk and Cd93, that play roles in phagocytosis of apoptotic cells and modulate inflammation. A candidate gene for Aath5 is Stab2, the DBA allele of which is associated with 10 times higher plasma hyaluronan than the 129 allele. Overall, our identification of two new QTL that affect atherosclerosis in an aortic arch-specific manner further supports the involvement of distinct pathological processes at different vascular locations. PMID:25689165
Dominguez-Rodriguez, Alberto; Thibodeau, Jennifer T; Ayers, Colby R; Jimenez-Sosa, Alejandro; Garrido, Pilar; Montoto, Javier; Prada-Arrondo, Pablo C; Abreu-Gonzalez, Pedro; Drazner, Mark H
2018-06-02
Bendopnea is a recently described symptom of advanced heart failure. Its prevalence and prognostic utility in other cardiac conditions are unknown. We prospectively enrolled 108 consecutive patients (75 ± 3 years, 68% men) with severe symptomatic aortic stenosis referred for surgical aortic valve replacement (SAVR). Preoperatively, patients were tested for bendopnea, which was considered to be present when dyspnoea occurred within 30 s of bending forward. Univariable and stepwise multivariable analyses tested the association of bendopnea with preoperative echocardiographic parameters and postoperative clinical outcomes. Bendopnea was present in 46 of 108 (42%) patients. The mean time of onset was 10.5 ± 3.4 s. Bendopnea was associated with higher estimated pulmonary artery systolic pressures [51 (11) mmHg vs 40 (11) mmHg), P < 0.0001], smaller aortic valve area [0.66 (0.16) cm2 vs 0.76 (0.13) cm2, P = 0.0006] and longer duration of mechanical ventilation (P = 0.002) and length of stay in the hospital (P = 0.007). Following SAVR, in-hospital mortality in those with bendopnea versus those without bendopnea was 13% vs 3% (P = 0.07). In multivariable analysis, bendopnea was associated with duration of mechanical ventilation (parameter estimate 2.4, P < 0.0001) and length of stay in the hospital (parameter estimate 10.2, P ≤ 0.0001). Bendopnea was present in a sizeable minority of patients (42%) with severe aortic stenosis referred for SAVR. Bendopnea was associated with higher pulmonary artery systolic pressure and smaller aortic valve area preoperatively and with longer duration of mechanical ventilation and length of hospitalization postoperatively. These data suggest that bendopnea provides prognostic information in patients with severe aortic stenosis undergoing SAVR.
Aortic root remodeling: ten-year experience with 274 patients.
Aicher, Diana; Langer, Frank; Lausberg, Henning; Bierbach, Benjamin; Schäfers, Hans-Joachim
2007-10-01
Dilatation of the aortic root with concomitant aortic regurgitation can be treated by valve-preserving surgery. We have consistently chosen root remodeling rather than reimplantation whenever the aortoventricular junction was not dilated. We have analyzed our 11-year experience with root remodeling. Between October 1995 and October 2006, 274 patients (201 male; 73 female, aged 59 +/- 15 years) were treated by root remodeling in the presence of a preserved aortoventricular diameter (<30 mm). Acute aortic dissection was present in 46 patients. The valve anatomy was tricuspid in 193 and bicuspid in 81 patients. Cusp disease was additionally corrected in 173 (63%) patients. Follow-up was complete in 99%. Cumulative follow-up was 1045 patient-years (mean of 4.0 +/- 2.7 years). Hospital mortality was 3.6% (elective 3.1%; emergency 6.5%). One patient had endocarditis 2 months postoperatively and subsequently underwent valve replacement. Freedom from aortic regurgitation of grade II or more was 91% and 87% at 10 years for bicuspid and tricuspid aortic valves. Nine patients required reoperation: in 6 patients the valve was replaced and in 3 patients rerepaired. Freedom from reoperation was 96% at 5 and 10 years, and freedom from valve replacement was 98% at 5 and 10 years. A comparison of 3 operative periods (1995-1998, 1999-2002, and 2003-2006) showed that with increasing experience cusp prolapse was diagnosed and corrected more frequently (8/49 = 17%; 62/105 = 59%; 103/108 = 82%; P < .0001), and repair stability significantly improved over time (P = .007). Root remodeling leads to durable restoration of aortic valve function in both tricuspid and bicuspid valve anatomy. Aggressive correction of cusp prolapse seems to have a beneficial effect on aortic valve competence.
Possible extracardiac predictors of aortic dissection in Marfan syndrome
2014-01-01
Background According to previous studies, aortic diameter alone seems to be insufficient to predict the event of aortic dissection in Marfan syndrome (MFS). Determining the optimal schedule for preventive aortic root replacement (ARR) aortic growth rate is of importance, as well as family history, however, none of them appear to be decisive. Thus, the aim of this study was to search for potential predictors of aortic dissection in MFS. Methods A Marfan Biobank consisting of 79 MFS patients was established. Thirty-nine MFS patients who underwent ARR were assigned into three groups based on the indication for surgery (dissection, annuloaortic ectasia and prophylactic surgery). The prophylactic surgery group was excluded from the study. Transforming growth factor-β (TGF-β) serum levels were measured by ELISA, relative expression of c-Fos, matrix metalloproteinase 3 and 9 (MMP-3 and −9) were assessed by RT-PCR. Clinical parameters, including anthropometric variables - based on the original Ghent criteria were also analyzed. Results Among patients with aortic dissection, TGF-β serum level was elevated (43.78 ± 6.51 vs. 31.64 ± 4.99 ng/l, p < 0.0001), MMP-3 was up-regulated (Ln2α = 1.87, p = 0.062) and striae atrophicae were more common (92% vs. 41% p = 0.027) compared to the annuloaortic ectasia group. Conclusions We found three easily measurable parameters (striae atrophicae, TGF-β serum level, MMP-3) that may help to predict the risk of aortic dissection in MFS. Based on these findings a new classification of MFS, that is benign or malignant is also proposed, which could be taken into consideration in determining the timing of prophylactic ARR. PMID:24720641
Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome.
Arnold, Raoul; Neu, Marie; Hirtler, Daniel; Gimpel, Charlotte; Markl, Michael; Geiger, Julia
2017-04-01
Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections.
Thomas, J D; Flachskampf, F A; Chen, C; Guererro, J L; Picard, M H; Levine, R A; Weyman, A E
1992-11-01
The isovolumic relaxation time (IVRT) is an important noninvasive index of left ventricular diastolic function. Despite its widespread use, however, the IVRT has not been related analytically to invasive parameters of ventricular function. Establishing such a relationship would make the IVRT more useful by itself and perhaps allow it to be combined more precisely with other noninvasive parameters of ventricular filling. The purpose of this study was to validate such a quantitative relationship. Assuming isovolumic relaxation to be a monoexponential decay of ventricular pressure (pv) to a zero-pressure asymptote, it was postulated that the time interval from aortic valve closure (when pv = p(o)) until mitral valve opening (when pv = left atrial pressure, pA) would be given analytically by IVRT = tau[log(p(o))-log(pA)], where tau is the time constant of isovolumic relaxation and log is to the base e. To test this hypothesis we analyzed data from six canine experiments in which ventricular preload and afterload were controlled nonpharmacologically. In addition, tau was adjusted with the use of beta-adrenergic blockade and calcium infusion, as well as with hypothermia. In each experiment data were collected before and after the surgical formation of mitral stenosis, performed to permit the study of a wide range of left atrial pressures. High-fidelity left atrial, left ventricular, and aortic root pressures were digitized, the IVRT was measured from the aortic dicrotic notch until the left atrioventricular pressure crossover point, and tau was calculated by nonlinear least-squares regression.(ABSTRACT TRUNCATED AT 250 WORDS)
Vascular complications of transcatheter aortic valve replacement: A concise literature review
Chaudhry, Muhammad Ali; Sardar, Muhammad Rizwan
2017-01-01
Transcatheter aortic valve replacement (TAVR) is a relatively newer therapeutic modality which offers a promising alternative to surgical aortic valve replacement for patients with prohibitive, high and intermediate surgical risk. The increasing trend to pursue TAVR in these patients has also led to growing awareness of the associated potential vascular complications. The significant impact of these complications on eventual clinical outcome and mortality makes prompt recognition and timely management a critical factor in TAVR patients. We hereby present a concise review with emphasis on diverse vascular complications associated with TAVR and their effective management to improve overall clinical outcomes. PMID:28824787
A Protocol for Diagnosis and Management of Aortic Atherosclerosis in Cardiac Surgery Patients
Brandon Bravo Bruinsma, George J.; Van 't Hof, Arnoud W. J.; Grandjean, Jan G.; Nierich, Arno P.
2017-01-01
In patients undergoing cardiac surgery, use of perioperative screening for aortic atherosclerosis with modified TEE (A-View method) was associated with lower postoperative mortality, but not stroke, as compared to patients operated on without such screening. At the time of clinical implementation and validation, we did not yet standardize the indications for modified TEE and the changes in patient management in the presence of aortic atherosclerosis. Therefore, we designed a protocol, which combined the diagnosis of atherosclerosis of thoracic aorta and the subsequent considerations with respect to the intraoperative management and provides a systematic approach to reduce the risk of cerebral complications. PMID:28852575
Infrarenal Abdominal Aortic Pseudoaneurysm: Is It a Real Emergency?
Massara, Mafalda; Prunella, Roberto; Gerardi, Pasquale; Lillo, Antonio; De Caridi, Giovanni; Serra, Raffaele; Notarstefano, Stefano; Impedovo, Giovanni
2017-01-01
Abdominal aortic pseudoaneurysm is a rare but life-threatening condition that occurs due to penetrating or blunt trauma. Clinical manifestations are variable, and the time interval from the initial trauma to diagnosis is variable. A prompt diagnosis and an aggressive management approach are required to avoid catastrophic complications. Possible treatment options are open surgical repair, endovascular repair, pseudoanerysmal sac thrombosis induction through direct thrombin injection, and coil embolization. Here, we present the case of a 75-year-old man affected by an infrarenal abdominal aortic pseudoaneurysm presenting with abdominal and lumbar pain for 3 days, who was successfully treated with an endograft. PMID:29515707
Double aortic arch and persistent left vena cava in a white lion cub (Panthera leo).
Goldin, J P; Lambrechts, N E
1999-03-01
A 4-mo-old female white lion (Panthera leo) cub was presented with a 2-wk history of persistent postprandial regurgitation, mild dyspnea, and poor weight gain. The cub was weak and thin but otherwise alert. Survey and contrast radiography revealed a large dilated esophagus cranial to the heart base, with an esophageal filling defect present at the level of the fourth thoracic vertebra. A vascular ring anomaly was tentatively diagnosed. Exploratory thoracotomy revealed a double aortic arch and a persistent left vena cava. The left aortic arch was ligated and divided, and recovery was uneventful. A single episode of regurgitation occurred within the first postoperative month, and the cub gained 5.5 kg in weight during the same time period. Neither double aortic arch nor persistent left vena cava has been reported in a nondomestic felid.
NASA Technical Reports Server (NTRS)
Belrose, Charles R. (Inventor)
1994-01-01
A saddle clamp assembly is presented. The assembly is comprised of a hollow cylindrical body centered about a longitudinal axis and being diametrically split into semicircular top and bottom sections. Each section has a pair of connection flanges, at opposite ends, that project radially outward. A pair of bolts are retained on the top section flanges and are threadable into nuts retained on the bottom section flanges. A base member is anchored to a central underside portion of the bottom clamp body section and has a pair of connection tabs positioned beneath the bottom clamp body section connection flanges on opposite sides of the clamp axis. A pair of bolts are retained on the base member connection tabs and are threadable into a pair of nuts retainable on a support structure. The connection tab and connection flanges on each side of the clamp body are axially offset in a manner permitting downward installation/removable tool access to the lower bolts past the connection flanges. An elongated retention tether is used to connect the top clamp body section to the balance of the clamp assembly. This prevents loss of the top clamp body section when it is removed from the bottom clamp body section.