Moorjani, Narain; Modi, Amit; Mattam, Kavita; Barlow, Clifford; Tsang, Geoffrey; Haw, Marcus; Livesey, Steven; Ohri, Sunil
2010-05-01
The Biovalsalva aortic root prosthesis incorporates an Elan porcine stentless biological aortic valve suspended within a triple-layered vascular conduit with preformed aortic sinuses of Valsalva. This study compared implantation of the Biovalsalva prosthesis with a "handsewn" composite bioprosthetic graft (CE Perimount bovine bioprosthesis anastomosed to a gelatin-impregnated gelweave Dacron graft). Between December 2004 and January 2009, 39 patients underwent elective or urgent aortic root replacement (modified Bentall procedure with coronary button reimplantation) using a Biovalsalva (n = 21) or a handsewn bioprosthesis (n = 18) for aortic root dilatation. There was no significant difference in the preoperative variables between the two study groups including age (70.7 +/- 1.7 vs. 67.6 +/- 2.9 years, p > 0.05). There was no in-hospital mortality. Three patients in each group underwent concomitant aortic hemi-arch replacement. Patients who underwent Biovalsalva implantation had a reduced need for transfusion of blood (1.25 +/- 0.32 vs. 3.17 +/- 0.71 units, p < 0.05) and fresh frozen plasma (2.78 +/- 0.39 vs. 1.85 +/- 0.31, p < 0.05), and reduced mediastinal blood loss (416 +/- 52 vs. 583 +/- 74 mL, p < 0.05) compared to those with a handsewn bioprosthesis. Cardiopulmonary bypass time (141 +/- 6 vs. 170 +/- 17 minutes, p = NS) and aortic cross-clamp time (113 +/- 6 vs. 115 +/- 7 minutes, p = NS) were similar. Postoperative echocardiography demonstrated excellent hemodynamic function of the Biovalsalva prosthesis (mean size 25.1 +/- 0.4 mm valved conduit) with a peak pressure gradient of 26.2 +/- 1.9 mmHg and no or trivial valvular regurgitation. The Biovalsalva prosthesis should be considered for patients requiring a biological aortic root replacement. It offers an "off-the-shelf" preassembled composite biological valve conduit with excellent hemostatic and hemodynamic properties.
Scharfschwerdt, Michael; Leonhard, Moritz; Lehmann, Judith; Richardt, Doreen; Goldmann, Helmut; Sievers, Hans-Hinrich
2016-05-01
Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular prosthesis providing elastic behaviours. In a first series (n = 14), haemodynamics and leaflet motions of the aortic valve were investigated and also cyclic changes of aortic dimensions at different levels of the root. In a second series (n = 7), intravascular pressure and dimensions of the proximal descending aorta were measured and the corresponding wall tension was calculated. Haemodynamics of the aortic valve remain comparable after replacement. Though the novel prosthesis does not feature such high distensibility as the native aorta, the dynamic of the root was significantly increased compared with common Dacron prostheses at the commissural level, preserving 'windkessel' function. Thus, wall tension of the residual aorta remained unchanged; nevertheless, maximum pressure-time differential dp/dt increased by 13%. The use of the novel elastic prosthesis for replacement of the ascending aorta seems to be beneficial, especially with regard to the preservation of the aortic windkessel. Further studies will be needed to clarify long-term utilization of the material in vivo. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Sponga, Sandro; Mazzaro, Enzo; Bagur, Rodrigo; Livi, Ugolino
2017-04-01
A 40-year-old man underwent 4 aortic surgeries because of endocarditis and subsequent prosthesis dehiscence. At the last recurrence he presented with acute severe aortic regurgitation of a Pericarbon Freedom (LivaNova plc, London, UK) stentless bioprosthesis and a morphologically disarranged aortic root. He also presented with left ventricular dysfunction and a very low origin of the left coronary artery. Therefore, a fifth redo aortic valve replacement was considered at high surgical risk. Accordingly, before listing the patient for a heart transplantation, a transcatheter valve-in-valve implantation with the JenaValve (JenaValve Technology, GmbH, Munich, Germany) prosthesis was performed. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Re-do aortic root replacement after an allograft aortic root replacement.
Vrtik, Marian; Tesar, Peter J
2009-10-01
Structural degeneration of allograft aortic root is a global process. In addition to valvular degeneration, the allograft wall calcification poses a risk of systemic calcific embolization and late phase anastomotic aneurysm formation and rupture (anecdotal). Furthermore, the valve annulus is often small, and the tissues are rigid making the implantation of an adequately sized prosthesis within the allograft wall difficult. To avoid these issues, we routinely perform re-do aortic root replacement with either a mechanical valve conduit or bio-root composite graft. The technique has been successfully used in 22 consecutive patients with no operative mortality and minimal morbidity.
Roubelakis, Apostolos; Karangelis, Dimos; Sadeque, Syed; Yanagawa, Bobby; Modi, Amit; Barlow, Clifford W; Livesey, Steven A; Ohri, Sunil K
2017-07-01
The treatment of complex prosthetic valve endocarditis (PVE) with aortic root abscess remains a surgical challenge. Several studies support the use of biological tissues to minimize the risk of recurrent infection. We present our initial surgical experience with the use of an aortic xenograft conduit for aortic valve and root replacement. Between October 2013 and August 2015, 15 xenograft bioconduits were implanted for complex PVE with abscess (13.3% female). In 6 patients, concomitant procedures were performed: coronary bypass (n=1), mitral valve replacement (n=5) and tricuspid annuloplasty (n=1). The mean age at operation was 60.3±15.5 years. The mean Logistic European system for cardiac operating risk evaluation (EuroSCORE) was 46.6±23.6. The median follow-up time was 607±328 days (range: 172-1074 days). There were two in-hospital deaths (14.3% mortality), two strokes (14.3%) and seven patients required permanent pacemaker insertion for conduction abnormalities (46.7%). The mean length of hospital stay was 26 days. At pre-discharge echocardiography, the conduit mean gradient was 9.3±3.3mmHg and there was either none (n=6), trace (n=6) or mild aortic insufficiency (n=1). There was no incidence of mid-term death, prosthesis-related complications or recurrent endocarditis. Xenograft bioconduits may be safe and effective for aortic valve and root replacement for complex PVE with aortic root abscess. Although excess early mortality reflects the complexity of the patient population, there was good valve hemodynamics, with no incidence of recurrent endocarditis or prosthesis failure in the mid-term. Our data support the continued use and evaluation of this biological prosthesis in this high-risk patient cohort.
Horehledova, Barbora; Mihl, Casper; Hendriks, Babs M F; Eijsvoogel, Nienke G; Vainer, Jindrich; Veenstra, Leo F; Wildberger, Joachim E; Das, Marco
2018-06-16
Incorrect prosthesis size has direct impact on patient outcome after transcatheter aortic valve implantation (TAVI) procedure. Currently, annular diameter, area or perimeter may be used for prosthesis size selection. The aim was to evaluate whether the use different annular dimensions would result in the selection of different prosthesis sizes, when assessed in the same TAVI-candidate during the same phase of a cardiac cycle. Fifty consecutive TAVI-candidates underwent retrospectively ECG-gated computed tomography angiography (CTA). Aortic root dimensions were assessed in the 20% phase of the R-R interval. Annular short diameter, perimeter and area were used to select the prosthesis size, based on the industry recommendations for a self-expandable (Medtronic CoreValve; MCV) and balloon-expandable (Edwards Sapien XT Valve; ESV) valve. Complete agreement on selected prosthesis size amongst all three annular dimensions was observed in 62% (31/50; ESV) and 30% (15/50; MCV). Short aortic annulus measurement resulted in a smaller prosthesis size in 20% (10/50; ESV) and in 60% of cases (30/50; MCV) compared to the size suggested by both annular perimeter and area. In 18% (9/50; ESV) and 10% of cases (5/50; MCV) a larger prosthesis would have been selected based on annular perimeter compared to annular diameter and area. Prosthesis size derived from area was always in agreement with at least one other parameter in all cases. Aortic annulus area appears to be the most robust parameter for TAVI-prosthesis size selection, regardless of the specific prosthesis size. Short aortic annulus diameter may underestimate the prosthesis size, while use of annular perimeter may lead to size overestimation in some cases.
Prosthetic valve sparing aortic root replacement: an improved technique.
Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G
2008-10-01
We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.
Aorta-atria-septum combined incision for aortic valve re-replacement
Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong
2018-01-01
This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170
A planning system for transapical aortic valve implantation
NASA Astrophysics Data System (ADS)
Gessat, Michael; Merk, Denis R.; Falk, Volkmar; Walther, Thomas; Jacobs, Stefan; Nöttling, Alois; Burgert, Oliver
2009-02-01
Stenosis of the aortic valve is a common cardiac disease. It is usually corrected surgically by replacing the valve with a mechanical or biological prosthesis. Transapical aortic valve implantation is an experimental minimally invasive surgical technique that is applied to patients with high operative risk to avoid pulmonary arrest. A stented biological prosthesis is mounted on a catheter. Through small incisions in the fifth intercostal space and the apex of the heart, the catheter is positioned under flouroscopy in the aortic root. The stent is expanded and unfolds the valve which is thereby implanted into the aortic root. Exact targeting is crucial, since major complications can arise from a misplaced valve. Planning software for the perioperative use is presented that allows for selection of the best fitting implant and calculation of the safe target area for that implant. The software uses contrast enhanced perioperative DynaCT images acquired under rapid pacing. In a semiautomatic process, a surface segmentation of the aortic root is created. User selected anatomical landmarks are used to calculate the geometric constraints for the size and position of the implant. The software is integrated into a PACS network based on DICOM communication to query and receive the images and implants templates from a PACS server. The planning results can be exported to the same server and from there can be rertieved by an intraoperative catheter guidance device.
Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.
Badiu, Catalin C; Bleiziffer, Sabine; Eichinger, Walter B; Hettich, Ina; Krane, Markus; Bauernschmitt, Robert; Lange, Rüdiger
2011-03-01
The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the stented Hancock valve substitute. The key benefit of this bioprosthetic valved conduit was the simplified redo procedure.
An augmented magnetic navigation system for Transcatheter Aortic Valve Implantation.
Luo, Zhe; Cai, Junfeng; Nie, Yuanyuan; Wang, Guotai; Gu, Lixu
2013-01-01
This research proposes an augmented magnetic navigation system for Transcatheter Aortic Valve Implantation (TAVI) employing a magnetic tracking system (MTS) combined with a dynamic aortic model and intra-operative ultrasound (US) images. The dynamic 3D aortic model is constructed based on the preoperative 4D computed tomography (CT), which is animated according to the real time electrocardiograph (ECG) input of patient. And a preoperative planning is performed to determine the target position of the aortic valve prosthesis. The temporal alignment is performed to synchronize the ECG signals, intra-operative US image and tracking information. Afterwards, with the assistance of synchronized ECG signals, the contour of aortic root automatic extracted from short axis US image is registered to the dynamic aortic model by a feature based registration intra-operatively. Then the augmented MTS guides the interventionist to confidently position and deploy the aortic valve prosthesis to target. The system was validated by animal studies on three porcine subjects, the deployment and tilting errors of which are 3.17 ± 0.91 mm and 7.40 ± 2.89° respectively.
Nestola, M G C; Faggiano, E; Vergara, C; Lancellotti, R M; Ippolito, S; Antona, C; Filippi, S; Quarteroni, A; Scrofani, R
2017-02-01
We provide a computational comparison of the performance of stentless and stented aortic prostheses, in terms of aortic root displacements and internal stresses. To this aim, we consider three real patients; for each of them, we draw the two prostheses configurations, which are characterized by different mechanical properties and we also consider the native configuration. For each of these scenarios, we solve the fluid-structure interaction problem arising between blood and aortic root, through Finite Elements. In particular, the Arbitrary Lagrangian-Eulerian formulation is used for the numerical solution of the fluid-dynamic equations and a hyperelastic material model is adopted to predict the mechanical response of the aortic wall and the two prostheses. The computational results are analyzed in terms of aortic flow, internal wall stresses and aortic wall/prosthesis displacements; a quantitative comparison of the mechanical behavior of the three scenarios is reported. The numerical results highlight a good agreement between stentless and native displacements and internal wall stresses, whereas higher/non-physiological stresses are found for the stented case.
Root replacement using stentless valves in the small aortic root: a propensity score analysis.
Kunihara, Takashi; Schmidt, Kathrin; Glombitza, Petra; Dzindzibadze, Vachtang; Lausberg, Henning; Schäfers, Hans-Joachim
2006-10-01
Root replacement using a stentless bioprosthesis may be the optimal approach to avoid patient-prosthesis mismatch in patients with a small aortic root. Primary root replacement, however, is considered to be associated with increased surgical risk. We compared early outcome of full root replacement with a stentless bioprosthesis with that of aortic valve replacement with a stented bioprosthesis using propensity score-matching analysis. Of 231 patients undergoing elective, first-time aortic valve replacement with a small root (< or = 22 mm), 120 patients were selected using propensity score-matching analysis. They underwent either root replacement using a 23-mm stentless bioprosthesis (stentless group, n = 60) or supra-annular aortic valve replacement using a 21-mm stented bioprosthesis (stented group, n = 60). Preoperative characteristics and frequency of concomitant operations were identical. Duration of operation (196 +/- 54 versus 174 +/- 49 minutes), cardiopulmonary bypass (112 +/- 36 versus 91 +/- 33 minutes), and aortic cross-clamping (76 +/- 21 versus 61 +/- 21 minutes) were significantly longer in the stentless group. However, the need for perioperative transfusion and the incidence of postoperative reexploration for bleeding (3% versus 8%) was lower, and ventilation time was shorter. Mean duration of intensive care and hospital stay were also significantly shorter (2.3 +/- 1.7 versus 4.0 +/- 3.9 days, 8.9 +/- 3.1 versus 12.4 +/- 5.7 days). In-hospital mortality was identical (5% each). No independent predictor for in-hospital mortality was identified. Full root replacement using a stentless bioprosthesis does not increase postoperative morbidity or mortality of aortic valve replacement and may be advantageous in patients with a small aortic root.
Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation.
Giroux, Sylvie K; Labinaz, Marino X; Grisoli, Dominique; Klug, Andrew P; Veinot, John P; Burwash, Ian G
2010-01-01
Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. Pannus formation usually restricts systolic excursion of the occluding disk, resulting in progressive stenosis of the aortic prosthesis. Intermittent dysfunction of a mechanical aortic prosthesis is usually ascribed to thrombus formation. We describe an unusual case of intermittent, noncyclic dysfunction of a mechanical aortic prosthesis due to pannus formation in the absence of systolic restriction of disk excursion that presented with intermittent massive aortic regurgitation, severe ischemia, and shock. Pannus formation should be considered as a potential cause of acute intermittent severe aortic regurgitation in a patient with a mechanical aortic prosthesis.
Sahiner, Levent; Asil, Serkan; Kaya, Ergün Baris; Ozer, Necla; Aytemir, Kudret
2016-10-01
Transcatheter aortic valve implantation (TAVI) has shown favorable outcomes in patients with severe symptomatic aortic valve stenosis who are at high surgical risk or inappropriate for open heart surgery. However, concerns exist over treating patients who have porcelain aorta and familial hypercholesterolemia, due to the potential complications of aortic root and aortic annulus. In this case report, we present a patient with familial hypercholesterolemia, symptomatic severe aortic stenosis, previous coronary artery bypass grafting and porcelain aorta, who was successfully treated with TAVI using a CoreValve. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kidher, Emaddin; Cheng, Zhuo; Jarral, Omar A; O'Regan, Declan P; Xu, Xiao Yun; Athanasiou, Thanos
2014-12-09
The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at the aortic root in patients implanted with BioValsalva™ composite valve-conduit using comprehensive MRI and computer technologies. Four male patients implanted with BioValsalva™ and 2 age-matched normal controls (NC) underwent cardiac magnetic resonance imaging (MRI). Phase-contrast imaging with velocity-mapping in 3 orthogonal directions was performed at the level of the aortic root and descending thoracic aorta. Computational fluid dynamic (CFD) simulations were performed for all the subjects with patient-specific flow information derived from phase-contrast MR data. The maximum and mean flow rates throughout the cardiac cycle at the aortic root level were very comparable between NC and BioValsalva™ patients (541 ± 199 vs. 567 ± 75 ml/s) and (95 ± 46 vs. 96 ± 10 ml/s), respectively. The maximum velocity (cm/s) was higher in patients (314 ± 49 vs. 223 ± 20; P = 0.06) due to relatively smaller effective orifice area (EOA), 2.99 ± 0.47 vs. 4.40 ± 0.24 cm2 (P = 0.06), however, the BioValsalva™ EOA was comparable to other reported prosthesis. The cross-sectional area and maximum diameter at the root were comparable between the two groups. BioValsalva™ conduit was stiffer than the native aortic wall, compliance (mm2 • mmHg(-1) • 10(-3)) values were (12.6 ± 4.2 vs 25.3 ± 0.4.; P = 0.06). The maximum time-averaged wall shear stress (Pa), at the ascending aorta was equivalent between the two groups, 17.17 ± 2.7 (NC) vs. 17.33 ± 4.7 (BioValsalva™ ). Flow streamlines at the root and ascending aorta were also similar between the two groups apart from a degree of helical flow that occurs at the outer curvature at the angle developed near the suture line. BioValsalva™ composite valve-conduit prosthesis is potentially comparable to native aortic root in structural design and in many hemodynamic parameters, although it is stiffer. Surgeons should pay more attention to the surgical technique to maximise the reestablishment of normal smooth aortic curvature geometry to prevent unfavourable flow characteristics.
Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan
2015-07-01
The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p<0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p<0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Long-Term Results of Aortic Root Surgery in Marfan Syndrome Patients: A Single-Center Experience.
Nicolo, Francesco; Romeo, Francesco; Lio, Antonio; Bovio, Emanuele; Scafuri, Antonio; Bassano, Carlo; Polisca, Patrizio; Pellegrino, Antonio; Nardi, Paolo; Chiariello, Luigi; Ruvolo, Giovanni
2017-07-01
The study aim was to compare long-term results of Marfan syndrome (MFS) patients affected by aortic root disease undergoing aortic root replacement with the Bentall or David operation. Since 1994, a total of 59 patients has been followed at the authors' Marfan Center, having undergone either a Bentall operation (Bentall group, n = 30) or a David operation (David group, n = 29). No operative mortality was recorded. After 20 years (mean follow up 97 ± 82 months; range 1 to 369 months) no prosthesis-related major bleeding or thromboembolic events had been observed; the 20-year survival was 94 ± 6% in the Bentall group, and 100% in the David group (p = 0.32). Freedom from reintervention for aortic valve dysfunction was 100% in the Bentall group, and 75 ± 13% in the David group (p = 0.04). This inter-group difference became relevant after the first eight-year period of follow-up, and was mainly associated with a particular familiar genetic phenotype involving three out of four reoperated patients. Freedom from all-cause death, myocardial infarction, stroke, prosthetic valve-related complications, and reintervention on any aortic segment was 69 ± 12% in the Bentall group, and 67 ± 14% in the David group (p = 0.33). The Bentall and David operations are both associated with satisfactory long-term results in MFS patients. The low rate of valve prosthesis-related complications suggested that the Bentall operation would continue to be a standard surgical treatment. The reimplantation technique, adopted for less-dilated aortas, provides satisfactory freedom from reoperation. Careful attention should be paid to the reimplantation technique in patients affected by a serious familiar genetic phenotype.
Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation
Spina, Roberto; Anthony, Chris; Muller, David WM
2015-01-01
Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674
Automatic aortic root segmentation in CTA whole-body dataset
NASA Astrophysics Data System (ADS)
Gao, Xinpei; Kitslaar, Pieter H.; Scholte, Arthur J. H. A.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Reiber, Johan H. C.
2016-03-01
Trans-catheter aortic valve replacement (TAVR) is an evolving technique for patients with serious aortic stenosis disease. Typically, in this application a CTA data set is obtained of the patient's arterial system from the subclavian artery to the femoral arteries, to evaluate the quality of the vascular access route and analyze the aortic root to determine if and which prosthesis should be used. In this paper, we concentrate on the automated segmentation of the aortic root. The purpose of this study was to automatically segment the aortic root in computed tomography angiography (CTA) datasets to support TAVR procedures. The method in this study includes 4 major steps. First, the patient's cardiac CTA image was resampled to reduce the computation time. Next, the cardiac CTA image was segmented using an atlas-based approach. The most similar atlas was selected from a total of 8 atlases based on its image similarity to the input CTA image. Third, the aortic root segmentation from the previous step was transferred to the patient's whole-body CTA image by affine registration and refined in the fourth step using a deformable subdivision surface model fitting procedure based on image intensity. The pipeline was applied to 20 patients. The ground truth was created by an analyst who semi-automatically corrected the contours of the automatic method, where necessary. The average Dice similarity index between the segmentations of the automatic method and the ground truth was found to be 0.965±0.024. In conclusion, the current results are very promising.
A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery.
Leone, Alessandro; Bruno, Piergiorgio; Cammertoni, Federico; Massetti, Massimo
2015-07-01
Valve-sparing operations for the treatment of aortic root disease with a structurally normal aortic valve are increasingly performed as they avoid prosthesis-related complications. Short- and long-term results are critically dependent on perfect intraoperative restoration of valve anatomy and function. Residual aortic regurgitation is the main cause of early failure, and it is the most common motive for reoperation. However, intraoperative morphofunctional valve assessment requires expertise, and only transesophageal echocardiography can provide reliable information. We describe a simple, economic, reproducible hydrostatic test to intraoperatively evaluate valve competency under direct visualization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Marwan, Mohamed; Achenbach, Stephan; Ensminger, Stefan M; Pflederer, Tobias; Ropers, Dieter; Ludwig, Josef; Weyand, Michael; Daniel, Werner G; Arnold, Martin
2013-06-01
Cardiac computed tomography (CT) allows accurate and detailed analysis of the anatomy of the aortic root and valve, including quantification of calcium. We evaluated the correlation between different CT parameters and the degree of post-procedural aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) using the balloon-expandable Edwards Sapien prosthesis. Pre-intervention contrast-enhanced dual source CT data sets of 105 consecutive patients (48 males, mean age 81 ± 6 years, mean logEuroSCORE 34 ± 13%) with symptomatic severe aortic valve stenosis referred for TAVI using the Edwards Sapien prosthesis (Edwards lifesciences, Inc., CA, USA) were analysed. The degrees of aortic valve commissural calcification and annular calcification were visually assessed on a scale from 0 to 3. Furthermore, the degree of aortic valve calcification as quantified by the Agatston score, aortic annulus eccentricity, aortic diameter at the level of the sinus of valsalva and at the sinotubular junction were assessed. Early post-procedural AR was assessed using aortography. Significant AR was defined as angiographic AR of at least moderate degree (AR ≥ 2). Visual assessment of the degree of aortic annular calcification as well as the Agatston score of aortic valve calcium correlated weakly, yet significantly with the degree of post-procedural AR (r = 0.31 and 0.24, p = 0.001 and 0.013, respectively). Compared to patients with AR < 2, patients with AR ≥ 2 showed more severe calcification of the aortic annulus (mean visual scores 1.9 ± 0.6 vs. 1.5 ± 0.6, p = 0.003) as well as higher aortic valve Agatston scores (1,517 ± 861 vs. 1,062 ± 688, p = 0.005). Visual score for commissural calcification did not differ significantly between both groups (mean scores 2.4 ± 0.5 vs. 2.5 ± 0.5, respectively, p = 0.117). No significant correlation was observed between the degree of AR and commissural calcification, aortic annulus eccentricity index or aortic diameters. The extent of aortic valve annular calcification, but not of commissural calcification, predicts significant post-procedural AR in patients referred for TAVI using the balloon-expandable Edwards Sapiens prosthesis.
Hasler, David; Obrist, Dominik
2018-01-01
The flow field past a prosthetic aortic valve comprises many details that indicate whether the prosthesis is functioning well or not. It is, however, not yet fully understood how an optimal flow scenario would look, i.e. which subtleties of the fluid dynamics in place are essential regarding the durability and compatibility of a prosthetic valve. In this study, we measured and analyzed the 3D flow field in the vicinity of a bio-prosthetic heart valve in function of the aortic root size. The measurements were conducted within aortic root phantoms of different size, mounted in a custom-built hydraulic setup, which mimicked physiological flow conditions in the aorta. Tomographic particle image velocimetry was used to measure the 3D instantaneous velocity field at various instances. Several 3D fields (e.g. instantaneous and mean velocity, 3D shear rate) were analyzed and compared focusing on the impact of the aortic root size, but also in order to gain general insight in the 3D flow structure past the bio-prosthetic valve. We found that the diameter of the aortic jet relative to the diameter of the ascending aorta is the most important parameter in determining the characteristics of the flow. A large aortic cross-section, relative to the cross-section of the aortic jet, was associated with higher levels of turbulence intensity and higher retrograde flow in the ascending aorta.
"Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve).
Vavouranakis, Manolis; Vrachatis, Dimitrios A; Toutouzas, Konstantinos P; Chrysohoou, Christina; Stefanadis, Christodoulos
2010-11-05
Two techniques for correcting malpositioning occurring during percutaneous aortic valve replacement (PAVR) with the CoreValve ReValving™ System are described in this article. The "Removing and Reinserting Technique" was used in 2 patients, in whom the prosthesis was positioned too high. The "Snare Technique" was used in 1 patient, in whom the prosthesis was implanted too low. In all patients the aortic valve prosthesis was successfully re-implanted. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Hu, Jia; Qian, Hong; Li, Ya-jiao; Gu, Jun; Zhao, Jing Janice; Zhang, Er-yong
2014-01-17
The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2)
Intermittent, Non Cyclic Severe Mechanical Aortic Valve Regurgitation
Choi, Jong Hyun; Song, Seunghwan; Lee, Myung-Yong
2013-01-01
Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. We describe an unusual case of intermittent, non cyclic mechanical aortic prosthesis dysfunction due to pannus formation with thrombus in the absence of systolic restriction of disk excursion, that presented with intermittent severe aortic regurgitation. PMID:24459568
Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin
2015-01-01
Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380
Drobinski, G; Thomas, D; Funck, F; Metzger, J P; Canny, M; Grosgogeat, Y
1986-08-01
Certain surgical techniques may make it difficult to catheterize the coronary ostia and perform percutaneous coronary angioplasty. We report the case of a 48 year old patient who developed unstable angina four years after a Bentall's procedure with reimplantation of the coronary arteries on a Dacron coronary prosthesis. The anginal pain was related to very severe stenosis of the proximal segment of the left anterior descending artery. The difficulties encountered during the dilatation procedure were due to: (a) the ectopic position of the ostium of the prosthesis on the anterior aortic wall; (b) the forces exerted on the aortic prosthesis wall and on the valvular prosthesis during positioning of the guiding catheter which were poorly tolerated and induced a vagal reaction; (c) the direction taken by the distal tip of the guiding catheter, perpendicular to the wall of the aortic prosthesis; (d) the sinuosity of the arterial trajectory: the left coronary segment of the coronary prosthesis was directed towards the left circumflex artery rather than towards the left anterior descending artery. Coronary angioplasty succeeded after relatively complex technical procedures: special guiding catheter, unusual intra-aortic manoeuvres for positioning the guiding catheter, dilatation catheter change on a 3-metre long guide wire in order to cross the stenotic segment; this was performed with a super low-profiled dilatation catheter. There were no complications and anginal pain disappeared.
Aortic Root Replacement for Children With Loeys-Dietz Syndrome.
Patel, Nishant D; Alejo, Diane; Crawford, Todd; Hibino, Narutoshi; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A
2017-05-01
Loeys-Dietz syndrome (LDS) is an aggressive aortopathy with a proclivity for aortic aneurysm rupture and dissection at smaller diameters than other connective tissue disorders. We reviewed our surgical experience of children with LDS to validate our guidelines for prophylactic aortic root replacement (ARR). We reviewed all children (younger than 18 years) with a diagnosis of LDS who underwent ARR at our institution. The primary endpoint was mortality, and secondary endpoints included complications and the need for further interventions. Thirty-four children with LDS underwent ARR. Mean age at operation was 10 years, and 15 (44%) were female. Mean preoperative root diameter was 4 cm. Three children (9%) had composite ARR with a mechanical prosthesis, and 31 (91%) underwent valve-sparing ARR. Concomitant procedures included arch replacement in 2 (6%), aortic valve repair in 1 (3%), and patent foramen ovale closure in 16 (47%). There was no operative mortality. Two children (6%) required late replacement of the ascending aorta, 5 (15%) required arch replacement, 1 (3%) required mitral valve replacement, and 2 (6%) had coronary button aneurysms/pseudoaneurysms requiring repair. Three children required redo valve-sparing ARR after a Florida sleeve procedure, and 2 had progressive aortic insufficiency requiring aortic valve replacement after a valve-sparing procedure. There were 2 late deaths (6%). These data confirm the aggressive aortopathy of LDS. Valve-sparing ARR should be performed when feasible to avoid the risks of prostheses. Serial imaging of the arterial tree is critical, given the rate of subsequent intervention. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ouzounian, Maral; Rao, Vivek; Manlhiot, Cedric; Abraham, Nachum; David, Carolyn; Feindel, Christopher M; David, Tirone E
2016-10-25
Although aortic valve-sparing (AVS) operations are established alternatives to composite valve graft (CVG) procedures for patients with aortic root aneurysms, comparative long-term outcomes are lacking. This study sought to compare the results of patients undergoing AVS procedures with those undergoing CVG operations. From 1990 to 2010, a total of 616 patients age <70 years and without aortic stenosis underwent elective aortic root surgery (AVS, n = 253; CVG with a bioprosthesis [bio-CVG], n = 180; CVG with a mechanical prosthesis [m-CVG], n = 183). A propensity score was used as a covariate to adjust for unbalanced variables in group comparisons. Mean age was 46 ± 14 years, 83.3% were male, and mean follow-up was 9.8 ± 5.3 years. Patients undergoing AVS had higher rates of Marfan syndrome and lower rates of bicuspid aortic valve than those undergoing bio-CVG or m-CVG procedures. In-hospital mortality (0.3%) and stroke rate (1.3%) were similar among groups. After adjusting for clinical covariates, both bio-CVG and m-CVG procedures were associated with increased long-term major adverse valve-related events compared with patients undergoing AVS (hazard ratio [HR]: 3.4, p = 0.005; and HR: 5.2, p < 0.001, respectively). They were also associated with increased cardiac mortality (HR: 7.0, p = 0.001; and HR: 6.4, p = 0.003). Furthermore, bio-CVG procedures were associated with increased risk of reoperations (HR: 6.9; p = 0.003), and m-CVG procedures were associated with increased risk of anticoagulant-related hemorrhage (HR: 5.6; p = 0.008) compared with AVS procedures. This comparative study showed that AVS procedures were associated with reduced cardiac mortality and valve-related complications when compared with bio-CVG and m-CVG. AVS is the treatment of choice for young patients with aortic root aneurysm and normal or near-normal aortic cusps. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Aortic valve repair leads to a low incidence of valve-related complications.
Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim
2010-01-01
Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.
Scott, S M; Sethi, G K; Paulson, D M; Takaro, T
1978-04-01
Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.
Etz, Christian D; Girrbach, Felix F; von Aspern, Konstantin; Battellini, Roberto; Dohmen, Pascal; Hoyer, Alexandro; Luehr, Maximilian; Misfeld, Martin; Borger, Michael A; Mohr, Friedrich W
2013-09-10
The choice of the best conduit for root/ascending disease and its impact on longevity remain controversial in quinquagenarians. A total of 205 patients (men=155) between 50 and 60 years (mean, 55.7 ± 2.9 years) received either a stentless porcine xenoroot (n=78) or a mechanically valved composite prosthesis (n=127) between February 1998 and July 2011. Of these, 166 patients underwent root replacement for aneurysmal disease (porcine: 39% [n=65]; mechanical: 61% [n=101]; P=0.5), 25 for acute type A aortic dissection (porcine: 32% [n=8]; mechanical: 68% [n=17]; P=0.51), and 14 for endocarditis/iatrogenic injury involving the aortic root (6.4% [n=5] versus 7.1% [n=9]; P=1.0). The predominant aortic valve pathology was stenosis in 19% (n=38), regurgitation in 50% (n=102), combined valvular dysfunction in 26% (n=54), and normal aortic valve function in 5% (n=11). Concomitant procedures included coronary artery bypass grafting (13%), mitral valve repair (7%), and partial/complete arch replacement (12%/4%), with no significant differences between porcine and mechanical root replacement. Overall hospital mortality was 7.3%, with no difference between the 2 types of valve prostheses (7.7% for porcine and 7.1% for mechanical root replacement; P=1.0). Follow-up averaged 5.4 ± 3.7 years (1096 patient-years) and was 100% complete. Freedom from aorta-related reoperation at 12 years was not statistically different between the groups (porcine: 94.9% versus mechanical: 96.1%; P=0.73). Survival was equivalent between both groups, with a 5-year survival of 86 ± 3% (porcine: 88 ± 4%; mechanical: 85 ± 3%; P=0.96) and a 10-year survival of 76% (porcine: 80 ± 7%; mechanical: 75 ± 5%; P=0.84). The linearized mortality rate was 3.1%/patient-year (porcine: 2.9%/patient-year; mechanical: 3.2%/patient-year). In quinquagenerians, long-term survival after stentless porcine xenograft aortic root replacement is equivalent to that after a mechanical Bentall procedure. These results bring into question the predominance of mechanical composite conduits for root replacement in quinquagenerians, particularly in the current era of transcatheter valve-in-valve procedures for structural valve deterioration.
Sutherland, R D; Guynes, W A; Nichols, C T; Martinez, H E
1982-01-01
Excessive cage strut wear allowing ball-poppet embolization caused the sudden death of a 47 year old lady in whom a DeBakey-Surgitool aortic prosthesis had been implanted nine years earlier. Patients with this type of prosthesis should have periodic valvular cine fluoroscopy with image intensification to allow visualization of significant strut wear or fracture, and appropriate prosthetic valve replacement.
Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria
2018-01-01
Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (<3,025 arbitrary units) compared with patients with high AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Medium-term outcome of Toronto aortic valve replacement: single center experience.
Li, Wei; Price, Susanna; O'Sullivan, Christine A; Kumar, Pankaj; Jin, Xu Y; Henein, Michael Y; Pepper, John R
2008-09-26
Long-term competence of any aortic prosthesis is critical to its clinical durability. Bioprosthetic valves, and in particular the stentless type have been proposed to offer superior haemodynamic profiles with consequent potential for superior left-ventricular mass regression. These benefits however are balanced by the potential longevity of the implanted valve. The aims of this study were to assess medium-term Toronto aortic valve function and its effect on left-ventricular function. Between 1992 and 1996 86 patients underwent Toronto aortic valve replacement for aortic valve disease and were followed up annually. Prospectively collected data was analyzed for all patients where detailed echocardiographic follow-up was available. Echocardiographic studies were analyzed at 2+/-0.6 and 6+/-1.4 years after valve replacement. Data collected included left-ventricular systolic and diastolic dimensions, fractional shortening and left-ventricular mass. In addition, data on aortic valve and root morphology, peak aortic velocities, time velocity integral, stroke volume and the mechanism of valve failure where relevant, were also collected. Complete echocardiographic data were available for eighty-four patients, age 69+/-9 years, 62 male. Additional coronary artery bypass grafting was performed in 38% of patients. Twelve (14%) valves had failed during follow-up, 7 (8%) requiring re-operation. Valve failure was associated with morphologically bicuspid native aortic valve (9/12), and progressive dilatation of the aortic sinuses, sino-tubular junction and ascending aorta (11/12). Left-ventricular mass index remained high (184+/-75 g/m(2)) and did not continue to regress between early and medium-term follow-up (175.8+/-77 g/m(2)). Although more than 90% of implanted Toronto aortic valves remained haemodynamically stable with low gradient at medium-term follow-up, young age and larger aortic dimensions in patients with valve failure suggest better outcome if used in the elderly with normal aortic root geometry.
Visualizing anatomical evidences on atrioventricular conduction system for TAVI.
Kawashima, Tomokazu; Sato, Fumi
2014-06-01
Visualizing the anatomy of the atrioventricular (AV) conduction axis substantiates that there is remarkable inter-individual variation at the macro- and microscopic levels, and that the atrioventricular bundle and left bundle branch are located more anteriorly, distally, and cranially and much closer to the aortic root complex than previously thought. The AV conduction system may therefore be compromised during implantation of a transcatheter aortic valve prosthesis, which may account for the relatively high incidence of new cardiac conduction abnormalities when conventional prosthetic valves are used. The design of the newer JenaValve® may afford advantages over more conventional valves by avoiding the high-risk implantation area and the potential for coronary ostia obstruction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Inner tubing technique used for the treatment of anastomotic aneurism.
Gaspar, Márcio Teodoro da Costa; de Mattos, Bruno Vinicius Hortences; Sofia, Milena Cristina Dias; Mulatti, Grace Carvajal; Lederman, Alex
2016-01-01
The authors report the case of a 66-year-old male patient diagnosed with a pseudoaneurysm of the distal aorto-aortic anastomosis treated with the inner tubing technique. The patient had been operated on 1 year before when he had an aortic prosthesis implanted as treatment for a ruptured abdominal aortic aneurysm. The inner tubing technique was developed to facilitate the treatment in bifurcated vascular lesions, where endovascular conventional prosthesis is not available.
Lacalzada-Almeida, Juan; De la Rosa-Hernández, Alejandro; Izquierdo-Gómez, María Manuela; García-Niebla, Javier; Hernández-Betancor, Iván; Bonilla-Arjona, Juan Alfonso; Barragán-Acea, Antonio; Laynez-Cerdeña, Ignacio
2018-01-01
A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia.
Marfan Syndrome: new diagnostic criteria, same anesthesia care? Case report and review.
Araújo, Maria Rita; Marques, Céline; Freitas, Sara; Santa-Bárbara, Rita; Alves, Joana; Xavier, Célia
2016-01-01
Marfan's Syndrome (MFS) is a disorder of connective tissue, mainly involving the cardiovascular, musculoskeletal, and ocular systems. The most severe problems include aortic root dilatation and dissection. Anesthetic management is vital for the improvement on perioperative morbidity. 61-year-old male with MFS, presenting mainly with pectus carinatum, scoliosis, ectopia lens, previous spontaneous pneumothorax and aortal aneurysm and dissection submitted to thoracoabdominal aortic prosthesis placement. Underwent routine laparoscopic cholecystectomy due to lithiasis. Important findings on preoperative examination were thoracolumbar kyphoscoliosis, metallic murmur on cardiac exam. Chest radiograph revealed Cobb angle of 70°. Echocardiogram showed evidence of aortic mechanical prosthesis with no deficits. Preoperative evaluation should focus on cardiopulmonary abnormalities. The anesthesiologist should be prepared for a potentially difficult intubation. Proper positioning and limb support prior to induction is crucial in order to avoid joint injuries. Consider antibiotic prophylaxis for subacute bacterial endocarditis. The patient should be carefully positioned to avoid joint injuries. Intraoperatively cardiovascular monitoring is mandatory: avoid maneuvers that can lead to tachycardia or hypertension, control airway pressure to prevent pneumothorax and maintain an adequate volemia to decrease chances of prolapse, especially if considering laparoscopic surgery. No single intraoperative anesthetic agent or technique has demonstrated superiority. Adequate postoperative pain management is vitally important to avoid the detrimental effects of hypertension and tachycardia. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
[Marfan Syndrome: new diagnostic criteria, same anesthesia care? Case report and review].
Araújo, Maria Rita; Marques, Céline; Freitas, Sara; Santa-Bárbara, Rita; Alves, Joana; Xavier, Célia
2016-01-01
Marfan's Syndrome (MFS) is a disorder of connective tissue, mainly involving the cardiovascular, musculoskeletal, and ocular systems. The most severe problems include aortic root dilatation and dissection. Anesthetic management is vital for the improvement on perioperative morbidity. 61-year-old male with MFS, presenting mainly with pectus carinatum, scoliosis, ectopia lens, previous spontaneous pneumothorax and aortal aneurysm and dissection submitted to thoracoabdominal aortic prosthesis placement. Underwent routine laparoscopic cholecystectomy due to lithiasis. Important findings on preoperative examination were thoracolumbar kyphoscoliosis, metallic murmur on cardiac exam. Chest radiograph revealed Cobb angle of 70°. Echocardiogram showed evidence of aortic mechanical prosthesis with no deficits. Preoperative evaluation should focus on cardiopulmonary abnormalities. The anesthesiologist should be prepared for a potentially difficult intubation. Proper positioning and limb support prior to induction is crucial in order to avoid joint injuries. Consider antibiotic prophylaxis for subacute bacterial endocarditis. The patient should be carefully positioned to avoid joint injuries. Intraoperatively cardiovascular monitoring is mandatory: avoid maneuvers that can lead to tachycardia or hypertension, control airway pressure to prevent pneumothorax and maintain an adequate volemia to decrease chances of prolapse, especially if considering laparoscopic surgery. No single intraoperative anesthetic agent or technique has demonstrated superiority. Adequate postoperative pain management is vitally important to avoid the detrimental effects of hypertension and tachycardia. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Thirty-Seven-Year Durability of a Starr-Edwards Aortic Prosthesis
Ozkokeli, Mehmet; Ates, Mehmet; Ekinci, Abdurrahman; Akcar, Murat
2005-01-01
We report the case of a patient who was diagnosed with prosthetic valve endocarditis caused by Staphylococcus aureus. He had undergone aortic valve replacement with a Starr-Edwards prosthesis 37 years earlier. Because of uncontrolled infection despite antibiotic treatment, the patient underwent successful surgical replacement of the prosthetic valve. PMID:15902834
van Slooten, Ymkje J; van Melle, Joost P; Freling, Hendrik G; Bouma, Berto J; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C; Sieswerda, Gertjan T; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A; Pieper, Petronella G
2016-01-01
To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in life. However, the prevalence and clinical consequences of aortic PPM in ACHD are presently unknown. From the national Dutch Congenital Corvitia (CONCOR) registry, we identified 207 ACHD with an aortic valve prosthesis for this cross-sectional cohort study. Severe PPM was defined as an indexed effective orifice area ≤0.65 cm2/m2 and moderate PPM as an indexed orifice area ≤0.85 cm2/m2 measured using echocardiography. Exercise capacity was reported as percentage of predicted exercise capacity (PPEC). Of the 207 patients, 68% was male, 71% had a mechanical prosthesis and mean age at inclusion was 43.9 years ±11.4. The prevalence of PPM was 42%, comprising 23% severe PPM and 19% moderate PPM. Prevalence of PPM was higher in patients with mechanical prostheses (p<0.001). PPM was associated with poorer exercise capacity (mean PPEC 84% vs. 92%; p=0.048, mean difference =-8.3%, p=0.047). Mean follow-up was 2.6±1.1 years during which New York Heart Association (NYHA) class remained stable in most patients. PPM showed no significant effect on death or hospitalisation during follow-up (p=0.218). In this study we report a high prevalence (42%) of PPM in ACHD with an aortic valve prosthesis and an independent association of PPM with diminished exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Influence of type of aortic valve prosthesis on coronary blood flow velocity.
Jelenc, Matija; Juvan, Katja Ažman; Medvešček, Nadja Tatjana Ružič; Geršak, Borut
2013-02-01
Severe aortic valve stenosis is associated with high resting and reduced hyperemic coronary blood flow. Coronary blood flow increases after aortic valve replacement (AVR); however, the increase depends on the type of prosthesis used. The present study investigates the influence of type of aortic valve prosthesis on coronary blood flow velocity. The blood flow velocity in the left anterior descending coronary artery (LAD) and the right coronary artery (RCA) was measured intraoperatively before and after AVR with a stentless bioprosthesis (Sorin Freedom Solo; n = 11) or a bileaflet mechanical prosthesis (St. Jude Medical Regent; n = 11). Measurements were made with an X-Plore epicardial Doppler probe (Medistim, Oslo, Norway) following induction of hyperemia with an adenosine infusion. Preoperative and postoperative echocardiography evaluations were used to assess valvular and ventricular function. Velocity time integrals (VTI) were measured from the Doppler signals and used to calculate the proportion of systolic VTI (SF), diastolic VTI (DF), and normalized systolic coronary blood flow velocities (NSF) and normalized diastolic coronary blood flow velocities (NDF). The systolic proportion of the LAD VTI increased after AVR with the St. Jude Medical Regent prosthesis, which produced higher LAD SF and NSF values than the Sorin Freedom Solo prosthesis (SF, 0.41 ± 0.09 versus 0.29 ± 0.13 [P = .04]; NSF, 0.88 ± 0.24 versus 0.55 ± 0.17 [P = .01]). No significant changes in the LAD velocity profile were noted after valve replacement with the Sorin Freedom Solo, despite a significant reduction in transvalvular gradient and an increase in the effective orifice area. AVR had no effect on the RCA flow velocity profile. The coronary flow velocity profile in the LAD was significantly influenced by the type of aortic valve prosthesis used. The differences in the LAD velocity profile probably reflect differences in valve design and the systolic transvalvular flow pattern.
2011-01-01
Objectives To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. Methods Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. Results Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). Conclusions The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade. PMID:21699696
Tomographic PIV behind a prosthetic heart valve
NASA Astrophysics Data System (ADS)
Hasler, D.; Landolt, A.; Obrist, D.
2016-05-01
The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry. Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase-averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.
García-Herrera, Claudio M; Celentano, Diego J; Herrera, Emilio A
2017-03-01
Marfan syndrome (MFS) is a genetic disorder that affects connective tissue, impairing cardiovascular structures and function, such as heart valves and aorta. Thus, patients with Marfan disease have a higher risk of developing circulatory problems associated with mitral and aortic valves prolapse, manifested as dilated aorta and aortic aneurysm. However, little is known about the biomechanical characteristics of these structures affected with MFS. This study presents the modelling and simulation of the mechanical response of human ascending aortic aneurysms in MFS under in vivo conditions with intraluminal pressures within normotensive and hypertensive ranges. We obtained ascending aortic segments from five adults with MFS subjected to a vascular prosthesis implantation replacing an aortic aneurysm. We characterised the arterial samples via ex vivo tensile test measurements that enable fitting the material parameters of a hyperelastic isotropic constitutive model. Then, these material parameters were used in a numerical simulation of an ascending aortic aneurysm subjected to in vivo normotensive and hypertensive conditions. In addition, we assessed different constraints related to the movement of the aortic root. Overall, our results provide not only a realistic description of the mechanical behaviour of the vessel, but also useful data about stress/stretch-based criteria to predict vascular rupture. This knowledge may be included in the clinical assessment to determine risk and indicate surgical intervention.
Effect of lifelong antibiotic treatment for aortic arch prosthesis infection.
Rupprecht, Leopold; Grosse, Jirka; Hellwig, Dirk; Schmid, Christof
2017-11-01
A patient who underwent multiple aortic operations suffered persistent infection of the ascending aorta and arch prosthesis and was finally treated with lifelong antibiotics. An 8-year follow-up with positron emission computed tomography is reported. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Liotta, Domingo; Haller, Jordan D.; Pisanu, Amadeo; Bracco, Daniel; Bertolozzi, Enrique
1979-01-01
The technique described here permits insertion of a large prosthesis into a small aortic annulus and avoids the necessity of additional procedures for enlarging the aortic ring. Inspection of the fibrous skeleton of the heart reveals that the large intervalvular trigone and the noncoronary sinus of Valsalva are remarkably elastic. Full advantage of this natural elasticity is achieved by suturing the prosthesis to the base of these structures from outside the aorta. Sutures are placed in the sinuses of the right and left cusps in the usual manner. Judicious application of this procedure allows the implantation of a No. 23 or No. 24 prosthesis in cases that would require a No. 19 or No. 21 with the use of conventional methods. Images PMID:15216322
Bouma, Wobbe; Jainandunsing, Jayant S; Khamooshian, Arash; van der Harst, Pim; Mariani, Massimo A; Natour, Ehsan
2017-02-01
A thorough understanding of mitral and aortic valve motion dynamics is essential in mastering the skills necessary for performing successful valve intervention (open or transcatheter repair or replacement). We describe a reproducible and versatile beating-heart mitral and aortic valve assessment and valve intervention training model in human cadavers. The model is constructed by bilateral ligation of the pulmonary veins, ligation of the supra-aortic arteries, creating a shunt between the descending thoracic aorta and the left atrial appendage with a vascular prosthesis, anastomizing a vascular prosthesis to the apex and positioning an intra-aortic balloon pump (IABP) in the vascular prosthesis, cross-clamping the descending thoracic aorta, and finally placing a fluid line in the shunt prosthesis. The left ventricle is filled with saline to the desired pressure through the fluid line, and the IABP is switched on and set to a desired frequency (usually 60-80 bpm). Prerepair valve dynamic motion can be studied under direct endoscopic visualization. After assessment, the IABP is switched off, and valve intervention training can be performed using standard techniques. This high-fidelity simulation model has known limitations, but provides a realistic environment with an actual beating (human) heart, which is of incremental value. The model provides a unique opportunity to fill a beating heart with saline and to study prerepair mitral and aortic valve dynamic motion under direct endoscopic visualization. The entire set-up provides a versatile beating-heart mitral and aortic valve assessment model, which may have important implications for future valve intervention training. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Genome analysis of Listeria ivanovii strain G770 that caused a deadly aortic prosthesis infection
Beye, M.; Gouriet, F.; Michelle, C.; Casalta, J.-P.; Habib, G.; Raoult, D.; Fournier, P.-E.
2016-01-01
We sequenced the genome of Listeria ivanovii strain G770, which caused a deadly infection of the thoracic aortic prosthesis of a 78-year-old man. The 2.9 Mb genome exhibited 21 specific genes among L. ivanovii strains, including five genes encoding a type I restriction modification system and one glycopeptide resistance gene. PMID:26933501
Late outcome analysis of the Braile Biomédica® pericardial valve in the aortic position
Azeredo, Lisandro Gonçalves; Veronese, Elinthon Tavares; Santiago, José Augusto Duncan; Brandão, Carlos Manuel de Almeida; Pomerantzeff, Pablo Maria Alberto; Jatene, Fabio Biscegli
2014-01-01
Objective Aortic valve replacement with Braile bovine pericardial prosthesis has been routinely done at the Heart Institute of the Universidade de São Paulo Medical School since 2006. The objective of this study is to analyze the results of Braile Biomédica® aortic bioprosthesis in patients with aortic valve disease. Methods We retrospectively evaluated 196 patients with aortic valve disease submitted to aortic valve replacement with Braile Biomédica® bovine pericardial prosthesis, between 2006 and 2010. Mean age was 59.41±16.34 years and 67.3% were male. Before surgery, 73.4% of patients were in NYHA functional class III or IV. Results Hospital mortality was 8.16% (16 patients). Linearized rates of mortality, endocarditis, reintervention, and structural dysfunction were 1.065%, 0.91%, 0.68% and 0.075% patients/year, respectively. Actuarial survival was 90.59±2.56% in 88 months. Freedom from reintervention, endocarditis and structural dysfunction was respectively 91.38±2.79%, 89.84±2.92% and 98.57±0.72% in 88 months. Conclusion The Braile Biomédica® pericardial aortic valve prosthesis demonstrated actuarial survival and durability similar to that described in the literature, but further follow up is required to assess the incidence of prosthetic valve endocarditis and structural dysfunction in the future. PMID:25372903
Jiang, Shengli; Gao, Changqing; Ren, Chonglei; Zhang, Tao
2012-06-01
Patients with Ehlers-Danlos syndrome (EDS) type IV, an inherited connective tissue disorder, are predisposed to vascular and digestive ruptures, and arterial ruptures account for the majority of deaths. A 31-year-old man with EDS presented with an intramural aortoatrial fistula, severe aortic regurgitation, mitral valve prolapse, and severe tricuspid valve insufficiency combined with a severely dilated left ventricle. Determining the best surgical option for the patient was not easy, especially regarding the course of action for the aortic root with a tear in the sinus of Valsalva. The fistula tract was closed at the aorta with suture and with a patch in the right atrium, the mitral valve was repaired with edge-to-edge suture and then annuloplasty with a Cosgrove ring, the aortic valve was replaced with a mechanical prosthesis, and a modified De Vega technique was used for the tricuspid valvuloplasty. The postoperative course was uncomplicated, and the patient was discharged 2 weeks later. The considerations made to arrive at the chosen surgical course of action in this complex case are reviewed.
Kong, William K F; Regeer, Madelien V; Poh, Kian K; Yip, James W; van Rosendael, Philippe J; Yeo, Tiong C; Tay, Edgar; Kamperidis, Vasileios; van der Velde, Enno T; Mertens, Bart; Ajmone Marsan, Nina; Delgado, Victoria; Bax, Jeroen J
2018-04-14
Transcatheter aortic valve replacement (TAVR) has been shown safe and feasible in patients with bicuspid aortic valve (BAV) morphology. Evaluation of inter-ethnic differences in valve morphology and function and aortic root dimensions in patients with BAV is important for the worldwide spread of this therapy in this subgroup of patients. Comparisons between large European and Asian cohorts of patients with BAV have not been performed, and potential differences between populations may have important implications for TAVR. The present study evaluated the differences in valve morphology and function and aortic root dimensions between two large cohorts of European and Asian patients with BAV. Aortic valve morphology was defined on transthoracic echocardiography according to the number of commissures and raphe: type 0 = no raphe and two commissures, type 1 = one raphe and two commissures, type 2 = two raphes and one commissure. Aortic stenosis and regurgitation were graded according to current recommendations. For this study, aortic root dimensions were manually measured on transthoracic echocardiograms at the level of the aortic annulus, sinus of Valsalva (SOV), sinotubular junction (STJ), and ascending aorta (AA). Of 1427 patients with BAV (45.2 ± 18.1 years, 71.9% men), 794 (55.6%) were Europeans and 633 (44.4%) were Asians. The groups were comparable in age and proportion of male sex. Asians had higher prevalence of type 1 BAV with raphe between right and non-coronary cusps than Europeans (19.7% vs. 13.6%, respectively; P < 0.001), whereas the Europeans had higher prevalence of type 0 BAV (two commissures, no raphe) than Asians (14.5% vs. 6.8%, respectively; P < 0.001). The prevalence of moderate and severe aortic regurgitation was higher in Europeans than Asians (44.2% vs. 26.8%, respectively; P < 0.001) whereas there were no differences in BAV with normal function or aortic stenosis. After adjusting for demographics, comorbidities, and valve function, the dimensions of the aortic annulus [mean difference 1.17 mm/m2, 95% confidence interval (CI) 0.96-1.39], SOV (mean difference 1.86 mm/m2, 95% CI 1.47-2.24), STJ (mean difference 0.52 mm/m2, 95% CI 0.14-0.90) and AA (mean difference 1.05 mm/m2, 95% CI 0.57-1.52) were significantly larger among Asians compared with Europeans. This large multicentre registry reports for the first time that Asians with BAV showed more frequently type 1 BAV (with fusion between right and non-coronary cusp) and have larger aortic dimensions than Europeans. These findings have important implications for prosthesis type and size selection for TAVR.
Bekeredjian, Raffi; Bodingbauer, Dorothea; Hofmann, Nina P; Greiner, Sebastian; Schuetz, Moritz; Geis, Nicolas A; Kauczor, Hans U; Bryant, Mark; Chorianopoulos, Emmanuel; Pleger, Sven T; Mereles, Derliz; Katus, Hugo A; Korosoglou, Grigorios
2015-03-01
To investigate if the extent of aortic valve calcification is associated with postprocedural prosthesis eccentricity and paravalvular regurgitation (PAR) in patients undergoing transcatheter aortic valve implantation (TAVI). Cardiac computed tomography angiography (CCTA) was performed before and 3 months after TAVI in 46 patients who received the self-expanding CoreValve and in 22 patients who underwent balloon-expandable Edwards Sapien XT implantation. Aortic annulus calcification was measured with CCTA prior to TAVI and prosthesis eccentricity was assessed with post-TAVI CCTA. Standard echocardiography was also performed in all patients at 3-month follow-up exam. Annulus eccentricity was reduced during TAVI using both implantation systems (from 0.23 ± 0.06 to 0.18 ± 0.07 using CoreValve and from 0.20 ± 0.07 to 0.05 ± 0.03 using Edwards Sapien XT; P<.001 for both). With Edwards Sapien XT, eccentricity reduction at the level of the aortic annulus was significantly higher compared with CoreValve (P<.001). Annulus eccentricity after CoreValve use was significantly related to absolute valve calcification and to valve calcification indexed to body surface area (BSA) (r = 0.48 and 0.50, respectively; P<.001 for both). Furthermore, a significant association was observed between aortic valve calcification and PAR (P<.01 by ANOVA) in patients who received CoreValve. Using ROC analysis, a cut-off value over 913 mm² aortic valve calcification predicted the occurrence of moderate or severe PAR with a sensitivity of 92% and a specificity of 63% (area under the curve = 0.75). Furthermore, multivariable analysis showed that aortic valve calcification was a robust predictor of postprocedural eccentricity and PAR, independent of the aortic annulus size and native valve eccentricity and of CoreValve prosthesis size (adjusted r = 0.46 and 0.50, respectively; P<.01 for both). Such associations were not present with the Edwards Sapien XT system. The extent of native aortic annulus calcification is predictive for postprocedural prosthesis eccentricity and PAR, which is an important marker for long-term mortality in patients undergoing TAVI. This observation applies for the CoreValve, but not for the Edwards Sapien XT valve.
Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard
2015-01-01
Introduction Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. Case study 1 The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs’ surface was found. A biological aortic prosthesis was reimplanted without complications. Case study 2 The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Conclusions Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach. PMID:26702274
Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard
2015-09-01
Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications. The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Precise and modern diagnostic methods facilitated selection of the treatment method. However, the intraoperative view also seems to be crucial in individualizing the surgical approach.
Influence of the tilt angle of Percutaneous Aortic Prosthesis on Velocity and Shear Stress Fields
Gomes, Bruno Alvares de Azevedo; Camargo, Gabriel Cordeiro; dos Santos, Jorge Roberto Lopes; Azevedo, Luis Fernando Alzuguir; Nieckele, Ângela Ourivio; Siqueira-Filho, Aristarco Gonçalves; de Oliveira, Glaucia Maria Moraes
2017-01-01
Background Due to the nature of the percutaneous prosthesis deployment process, a variation in its final position is expected. Prosthetic valve placement will define the spatial location of its effective orifice in relation to the aortic annulus. The blood flow pattern in the ascending aorta is related to the aortic remodeling process, and depends on the spatial location of the effective orifice. The hemodynamic effect of small variations in the angle of inclination of the effective orifice has not been studied in detail. Objective To implement an in vitro simulation to characterize the hydrodynamic blood flow pattern associated with small variations in the effective orifice inclination. Methods A three-dimensional aortic phantom was constructed, reproducing the anatomy of one patient submitted to percutaneous aortic valve implantation. Flow analysis was performed by use of the Particle Image Velocimetry technique. The flow pattern in the ascending aorta was characterized for six flow rate levels. In addition, six angles of inclination of the effective orifice were assessed. Results The effective orifice at the -4º and -2º angles directed the main flow towards the anterior wall of the aortic model, inducing asymmetric and high shear stress in that region. However, the effective orifice at the +3º and +5º angles mimics the physiological pattern, centralizing the main flow and promoting a symmetric distribution of shear stress. Conclusion The measurements performed suggest that small changes in the angle of inclination of the percutaneous prosthesis aid in the generation of a physiological hemodynamic pattern, and can contribute to reduce aortic remodeling. PMID:28793046
Choice of valve prosthesis in a rare clinical condition: aortic stenosis due to alkaptonuria.
Thakur, Sameer; Markman, Phuong; Cullen, Hugh
2013-10-01
Alkaptonuria is a rare inherited disorder of tyrosine metabolism, which results in deposition of homogentisic acid in the connective tissues. The accumulation of homogentisic acid in connective tissue causes the syndrome known as ochronosis, which is typically manifested by skin pigmentation, degenerative arthropathy and discolouration of urine. Cardiovascular involvement is a much less common complication of alkaptonuria but poses a greater risk to the patient's health. We present the case of a 65 year-old man with aortic stenosis and a previous diagnosis of alkaptonuria who underwent successful aortic valve replacement with a mechanical prosthesis. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Transcatheter aortic valve implantation transapical: step by step.
Walther, Thomas; Möllmann, Helge; van Linden, Arnaud; Kempfert, Jörg
2011-01-01
Transcatheter aortic valve implantation (T-AVI) has been introduced into clinical practice to treat high-risk elderly patients with aortic stenosis. T-AVI can be performed by using a retrograde transfemoral (TF), transsubclavian, transaortic, and/or antegrade transapical (TA) approach. For TA-AVI, CE mark approval was granted in 2008 for the Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis with the Ascendra delivery system and in 2010 for the second-generation Edwards SAPIEN XT prosthesis and the Ascendra II delivery system, with 23-mm and 26-mm valves. In 2011, CE mark approval has been granted for TA-AVI by using the SAPIEN XT 29-mm prosthesis. Several other devices from different companies (Jenavalve, Jena Valve Inc, Munich, Germany; Embracer, Medtronic Inc, Guilford, CT; Accurate, Symetis Inc, Geneva, Switzerland) have passed "first in man trials" successfully and are being evaluated within multicenter pivotal studies. In this article we will focus on specific aspects of the TA technique for AVI. Copyright © 2011 Elsevier Inc. All rights reserved.
Long-term follow-up of stentless prosthesis.
Sansone, Fabrizio; Dato, Guglielmo Mario Actis; Zingarelli, Edoardo; Ferrero, Emanuele; Prot, Sara; Ceresa, Fabrizio; Patanè, Francesco; Casabona, Riccardo
2014-05-01
Stentless prostheses have an interesting hemodynamic performance when compared to stented prostheses and are recommended in cases of small aortic annulus. From January 1996 to January 2004, 138 patients suffering from aortic disease, underwent aortic valve replacement. • Group A: 93 patients underwent stentless aortic valve implantation [stentless Biocor (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil) and stentless Sorin (Sorin Group, Saluggia, Italy)]. • Group B: 45 patients underwent stented aortic valve implantation (stented Biocor). Patients were assessed by clinical evaluation and echocardiography after a mean follow up of 124.5 ± 58.2 months. There was a significant difference in terms of time of extracorporeal circulation and aortic cross clamp. The actuarial survival at 4, 8, 12, and 15 years is 77%, 50%, 21%, and 18%, respectively. Freedom from reoperation at 4, 8, 12, and 14 years was 92%, 83%, 73%, and 63%, respectively. Freedom from all events, death, and reoperation at 4, 8, 12, and 14 years was 70%, 39%, 13%, and 8%, respectively. There is no statistical difference among the two groups in terms of actuarial survival, freedom from reoperation, and freedom from re-hospitalization for prosthesis-related causes. There was a significantly higher incidence of pacemaker implantation in Group A and the causes are not known. The rate of freedom from reoperation is high in both groups for the patients who remained alive. There was no statistical difference about prosthesis dysfunction between the two groups. The higher incidence of death in Group A cannot be explained by causes related to the prosthesis because there is no difference in terms of causes of death. Rates of reoperation did not differ between the two groups. The results obtained with stentless prostheses are encouraging even in long-term follow-up. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg
2017-09-10
Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.
Prakash, Ashwin; Adlakha, Himanshu; Rabideau, Nicole; Hass, Cara J; Morris, Shaine A; Geva, Tal; Gauvreau, Kimberlee; Singh, Michael N; Lacro, Ronald V
2015-08-18
Aortic diameter is an imperfect predictor of aortic complications in connective tissue disorders (CTDs). Novel indicators of vascular phenotype severity such as aortic stiffness and vertebral tortuosity index have been proposed. We assessed the relation between aortic stiffness by cardiac MRI, surgical root replacement, and rates of aortic root dilation in children and young adults with CTDs. Retrospective analysis of cardiac MRI data on children and young adults with a CTD was performed to derive aortic stiffness measures (strain, distensibility, and β-stiffness index) at the aortic root, ascending aorta, and descending aorta. Vertebral tortuosity index was calculated as previously described. Rate of aortic root dilation before cardiac MRI was calculated as change in echocardiographic aortic root diameter z score per year. In 83 CTD patients (median age, 24 years; range, 1-55; 17% <18 years of age; 60% male), ascending aorta distensibility was reduced in comparison with published normative values: median z score, -1.93 (range, -8.7 to 1.3; P<0.0001 versus normals). Over a median follow-up period of 2.7 years, there were no aortic dissections or deaths, but 16 of 83 (19%) patients underwent surgical aortic root replacement. In multivariable analysis, lower aortic root strain (P=0.05) and higher vertebral tortuosity index (P=0.01) were independently associated with aortic root replacement. Lower ascending aorta strain (P=0.02) was associated with a higher rate of aortic root dilation. Higher aortic stiffness is associated with higher rates of surgical aortic replacement and aortic root dilation in children and young adults with CTDs. © 2015 American Heart Association, Inc.
Evolving Practice Trends of Aortic Root Surgery in North America.
Caceres, Manuel; Ma, Yicheng; Rankin, J Scott; Saha-Chaudhuri, Paramita; Gammie, James S; Suri, Rakesh M; Thourani, Vinod H; Englum, Brian R; Esmailian, Fardad; Czer, Lawrence S; Puskas, John D; Svensson, Lars G
2014-08-19
Aortic-valve sparing (AVS) techniques have emerged as alternatives to composite graft-valve replacement (CVR) for treatment of aortic root aneurysm. This study analyzed recent practice trends of aortic root surgery using the Society of Thoracic Surgeons database. From January 2000 through June 2011, 31,747, Overall patients received AVS (n=3,585/31,747; 11.3%) or CVR (n=28,162/31,747; 88.7%). A High-Risk Subgroup was defined as: age >75 years, endocarditis, aortic stenosis, dialysis, multi-valve surgery, valve reoperation, or emergency/salvage status, and high-risk patients were less likely to receive AVS (n=20,356/31,747 [64.1%]; 6% AVS; unadjusted operative mortality 10.5% AVS and 11.7% CVR). The remaining patients comprised a Low-Risk Subgroup, in which AVS was more common (n=11,388/31,747 [35.9%]; 21% AVS; unadjusted operative mortality 1.4% AVS and 3.1% CVR). Procedural changes over 3 equal time periods (P1-P2-P3) were evaluated by Cochran-Armitage trends analysis. Compared to AVS, Overall CVR patients had worse baseline risk profiles and higher unadjusted operative mortality. In High-Risk patients, AVS mortality was comparable to CVR (10.5% vs 11.7%, p=0.19), but AVS mortality was lower in the Low-Risk group (1.4% vs 3%, p<0.0001). For P1/P2/P3, AVS percentages and trend p-values were: High-Risk (6%/6%/7%, p=0.26) and Low-Risk (12%/21%/25%, p<0.0001). CVR prosthesis type (mechanical/bioprosthesis/homograft) also changed: P1 (63%/22%/15%), P2 (58%/38%/4%), and P3 (53%/44%/3%) (all p<0.0001, except mechanical valves in High-Risk patients p=0.18). Patients receiving CVR tended to have higher risk profiles. AVS increased over time in Low-Risk patients while bioprostheses increased in CVR. Favorable outcomes support the trend toward further expansion of AVS. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
da Silva, Cristina; Sahlen, Anders; Winter, Reidar; Bäck, Magnus; Rück, Andreas; Settergren, Magnus; Manouras, Aristomenis; Shahgaldi, Kambiz
2014-12-01
To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 ± 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 ± 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) ≤ 0.85 cm(2)/m(2) and severe PPM as AVAi < 0.65 cm(2)/m(2). Immediately post-TAVI, moderate PPM was present in 25 and 28 % of patients worked up using 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.
Strut fracture in a Bjork-Shiley aortic valve prosthesis.
Lifschultz, B D; Donoghue, E R
1985-10-01
Strut fracture can be a life-threatening adverse effect of mechanical prosthetic heart valves. This complication has occurred in the DeBakey, the Beall, the Cooley-Cutter and, most recently, the Bjork-Shiley valves. We report the case of a 35-year-old man who died suddenly 16 months after a 60 degree Bjork-Shiley Convexo-Concave heart valve prosthesis was inserted in the aortic position. At autopsy, the two welded attachments of the valve's outlet strut had fractured. The valve's tilting disc was found in his abdominal aorta.
Kretzschmar, Daniel; Lauten, Alexander; Goebel, Bjoern; Doenst, Torsten; Poerner, Tudor C; Ferrari, Markus; Figulla, Hans R; Hamadanchi, Ali
2016-03-01
The assessment of aortic annular size is critical, and inappropriate sizing is thought to be a main reason of paravalvular aortic regurgitation. Multidetector computed tomograph is associated with the risk of contrast nephropathy. For optimal evaluation of the complex structure of the aortic annulus, three-dimensional (3D)-methods should be used. We therefore sought to determine the value of 3D-transoesophageal echocardiography (3D-TEE) for appropriate sizing. Hundred and one patients (mean age 81·4 years) with symptomatic aortic valve stenosis (AS) and high surgical risk profile (mean log. EuroScore 28·8%) being scheduled for transcatheter aortic valve implantation (TAVI) were included. 2D- and 3D-TEE were performed before the procedure to evaluate the aortic annulus diameter. Maximum, minimum and mean (max diameter + min diameter/2) annulus diameters were 24·7, 23·1 and 23. 9 mm in 3D-TEE and compared to 22·6 mm in 2D-TEE (P<0·001; 0·07; <0·001). The interobserver variability for 3D-TEE was low with a mean difference of 0·18 mm compared to 2D-TEE with 0·59 mm. The application of 3D-TEE caused a change of prosthesis size selection in 40% of patients compared to 2D-TEE. In this study, we implanted three different types of catheter-mounted valves (Edwards-SAPIEN(™) XT valve, CoreValve(™) and JenaValve(™) ). Final angiography confirmed valve competence (mild insufficiency) in 91%, and there was no aortic regurgitation greater than moderate in the follow-up echocardiographic evaluation. Assessment of aortic annulus dimensions for TAVI size selection can safely be performed with 3D-TEE only. Based on our results with significantly higher annulus diameter compared to 2D-TEE, we recommend 3D-TEE to reduce prosthesis undersizing. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Crowley, Olivia M; Doty, John R
2017-07-01
Aortic root replacement is indicated for aortic root aneurysm, small aortic root, and most root abscesses. This report describes the placement of a radiopaque marker during aortic root replacement using a Freestyle porcine bioprosthesis. This marker is a useful landmark during fluoroscopy for transcatheter valve-in-valve aortic valve replacement in the event of bioprosthesis degeneration. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Koldsland, S; Svennevig, J L; Abdelnoor, M; Aas, H; Semb, G
1992-01-01
In the 18 months up to July 1983, 120 Björk-Shiley convexo-concave prostheses with 70 degrees opening angle were implanted in 47 women and 61 men aged 19-78 (mean 58.6) years. The prosthetic valves were aortic in 65 cases, mitral in 23 and both aortic and mitral in 20 cases. Emergency operation was required in ten cases, and concomitant surgery was performed in 43 (39.8%). The early mortality was 5.5%. A follow-up study, comprising 498 patient years, revealed 73.1% 5-year survival. There were three mechanical failures of prosthesis, in one of which re-replacement was successful. Elective prosthesis replacement was performed in four other cases judged to be at high risk of strut fracture.
Urgent splenectomy in the course of prosthetic valve endocarditis.
Marcinkiewicz, Anna; Ostrowski, Stanisław; Pawłowski, Witold; Palczak, Artur; Adamek-Kośmider, Anna; Jaszewski, Ryszard
2014-06-01
We present a case of a 51-year-old male patient hospitalized due to acute coronary syndrome requiring stent implantation to the left main stem. Double antiplatelet therapy was commenced. After 2-3 days, the patient presented with high fever, dyspnea on exertion, pain in the chest, myalgia, and general weakness. Transthoracic (TTE) and transesophageal (TEE) echocardiography revealed abnormal, turbulent flow across the aortic prosthesis, which was probably caused by the presence of a pathological smooth and mobile structure (10 × 9 × 5 mm) in front of the aortic annulus. Blood cultures were positive and staphylococcal prosthetic valve endocarditis (PVE) was diagnosed. Despite antibiotic treatment, the patient's condition deteriorated, and he was referred for prosthesis reimplantation. After being transferred to the Cardiac Surgery Clinic, he presented with nausea, vomiting, and abdominal pain. The results of imaging examinations suggested spleen hematoma. The patient underwent an urgent splenectomy. Histopathological examination revealed a spleen infarction consequent to an embolic event and subscapular hematoma. On the 10(th) day after the laparotomy, cardiac surgery was performed. No large vegetations were found on the aortic prosthesis. The mechanical valve, implanted 20 years earlier, was functioning properly; it was intact and well healed. Several fragments of a thrombus and fibrous tissue, resembling a pannus and covered with minor calcifications, were removed from the ventricular surface of the discs. A decision was reached to leave the aortic prosthesis in situ. The valvular material culture revealed the presence of Streptococcus anginosus, and the antibiotic scheme was modified. The postoperative period was uneventful.
Aortic root dynamics and surgery: from craft to science.
Cheng, Allen; Dagum, Paul; Miller, D Craig
2007-08-29
Since the fifteenth century beginning with Leonardo da Vinci's studies, the precise structure and functional dynamics of the aortic root throughout the cardiac cycle continues to elude investigators. The last five decades of experimental work have contributed substantially to our current understanding of aortic root dynamics. In this article, we review and summarize the relevant structural analyses, using radiopaque markers and sonomicrometric crystals, concerning aortic root three-dimensional deformations and describe aortic root dynamics in detail throughout the cardiac cycle. We then compare data between different studies and discuss the mechanisms responsible for the modes of aortic root deformation, including the haemodynamics, anatomical and temporal determinants of those deformations. These modes of aortic root deformation are closely coupled to maximize ejection, optimize transvalvular ejection haemodynamics and-perhaps most importantly-reduce stress on the aortic valve cusps by optimal diastolic load sharing and minimizing transvalvular turbulence throughout the cardiac cycle. This more comprehensive understanding of aortic root mechanics and physiology will contribute to improved medical and surgical treatment methods, enhanced therapeutic decision making and better post-intervention care of patients. With a better understanding of aortic root physiology, future research on aortic valve repair and replacement should take into account the integrated structural and functional asymmetry of aortic root dynamics to minimize stress on the aortic cusps in order to prevent premature structural valve deterioration.
Successful treatment of pure aortic insufficiency with transapical implantation of the JenaValve.
Bleiziffer, Sabine; Mazzitelli, Domenico; Nöbauer, Christian; Ried, Thomas; Lange, Rüdiger
2013-08-01
Transcatheter aortic valve implantation was predominantly developed for patients with severe calcified aortic stenosis, as most devices are designed to anchor within the native valve calcium. We report on a patient with pure insufficiency of a non-calcified aortic valve, in whom an anatomically oriented catheter valve was implanted successfully. The design of the prosthesis with position feelers engaging the native aortic valve leaflets proved to be suitable for the treatment of pure aortic insufficiency. Georg Thieme Verlag KG Stuttgart · New York.
Sakamoto, Kosuke; Totsugawa, Toshinori; Hiraoka, Arudo; Tamura, Kentaro; Yoshitaka, Hidenori; Sakaguchi, Taichi
2018-05-30
An 88-year-old woman was diagnosed with aortic stenosis and an aortic annulus that was too narrow to perform transcatheter aortic valve implantation. Surgery was performed through a 7-cm right mini-thoracotomy at the fourth intercostal space. A 19-mm aortic valve bioprosthesis was implanted after root enlargement. The fourth intercostal space was a suitable site for aortic root enlargement because of the shorter skin-to-root distance and the detailed exposure of the aortic valve after cutting the aortic wall. This study concluded that minimally-invasive aortic valve replacement following root enlargement can be an option for the treatment of elderly patients with aortic stenosis accompanied by an annulus that is too small to perform transcatheter aortic valve implantation.
Rapid pannus formation after few months of obstructing aortic mechanical prosthesis.
Al-Alao, Bassel; Simoniuk, Urszula; Heron, Brian; Parissis, Haralabos
2015-11-01
We report a rare case of a prosthetic aortic valve obstruction due to pannus formation only 3 months following aortic and mitral valve replacement. Fragments of asymmetrical pannus formation affected one of the leaflets of the bi-leaflet mechanical valve; the leaflet appeared immobile due to pannus ingrowth into the mechanical skeleton resulting in encroachment of the leaflet, which in turn became immobile. The patient successfully underwent emergency redo-aortic valve replacement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmehl, Joerg, E-mail: joerg.schmehl@med.uni-tuebingen.de; Scharpf, Marcus; Brechtel, Klaus
2012-02-15
Malignancies of the aortic wall represent a rare condition, and only a few reports have covered cases of sarcomas arising at the site of a prosthesis made of Dacron. A coincidence with endovascular repair has only been reported in one case to date. We report a patient with epithelioid angiosarcoma and metastatic disease, which was found in an aneurysmal sac after endovascular aortic repair for abdominal aortic aneurysm.
Di Martino, Luigi F M; Soliman, Osama I I; van Gils, Lennart; Vletter, Wim B; Van Mieghem, Nicolas M; Ren, Ben; Galema, Tjebbe W; Schultz, Carl; de Jaegere, Peter P T; Di Biase, Matteo; Geleijnse, Marcel L
2017-06-01
Paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) is a complication with potentially severe consequences. The relation between native aortic root calcium burden, stent frame eccentricity and PVL was not studied before. Two-hundred-and-twenty-three consecutive patients with severe aortic stenosis who underwent TAVI with a Medtronic CoreValve System© and who had available pre-discharge transthoracic echocardiography were studied. Echocardiographic stent inflow frame eccentricity was defined as major-minor diameter in a short-axis view >2 mm. PVL was scored according to the updated Valve Academic Research Consortium (VARC-2) recommendations. In a subgroup of 162 (73%) patients, the calcium Agatston score was available. Stent frame eccentricity was seen in 77 (35%) of patients. The correlation between the Agatston score and stent frame eccentricity was significant (ρ = 0.241, P = 0.003). Paravalvular leakage was absent in 91 cases (41%), mild in 67 (30%), moderate in 51 (23%), and severe in 14 (6%) cases. The correlation between stent frame eccentricity and PVL severity was significant (ρ = 0.525, P < 0.0001). There was a relation between particular eccentric stent frame shapes and the site of PVL. Calcification of the aortic annulus is associated with a subsequent eccentric shape of the CoreValve prosthesis. This eccentric shape results in more PVL, with the localization of PVL related to the shape of stent frame eccentricity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Transapical JenaValve in a patient with mechanical mitral valve prosthesis.
O' Sullivan, Katie E; Casserly, Ivan; Hurley, John
2015-04-01
We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.
Valve sparing aortic replacement - root remodeling.
Lausberg, Henning F; Schäfers, Hans-Joachim
2006-01-01
Aortic root remodeling restores aortic root geometry and improves valve competence. We have used this technique whenever aorto-ventricular diameter is preserved. The operative technique is detained in this presentation. As a result of our 10-year experience with root remodeling we propose this operation as a reproducible option for patients with dilatation of the aortic root.
Le Couteulx, S; Caudron, J; Dubourg, B; Cauchois, G; Dupré, M; Michelin, P; Durand, E; Eltchaninoff, H; Dacher, J-N
2018-05-01
To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve. Copyright © 2017. Published by Elsevier Masson SAS.
Transcatheter heart valves for the treatment of aortic stenosis: state-of-the-art.
Del Valle-Fernández, R; Ruiz, C E
2008-10-01
Degenerative aortic stenosis is the most frequent heart valve disease. As an alternative to surgical aortic valve replacement, several companies are working on the development of new prosthesis designed to be deployed by transcatheter approaches. Both transfemoral and transapical techniques are feasible, and initial trials in high-risk patients show good procedural outcomes and mid-term (up to 2 years) functionality. Two first-generation prosthesis (Edwards-SAPIEN and CoreValve Revalving System) are commercially available in Europe, and a number of other second-generation valves (with the capabilities of repositioning and retrievability) are under evaluation. Among them, the Sadra-Lotus Valve, The Direct Flow Medical valve and the Paniagua Heart Valve have published first-in-man results; the JenaValve and AorTx devices have also been temporarily implanted in humans. The development of repositionable and retrievable prosthesis with improved profile is mandatory, and it is the main focus of current projects. Not only technical improvements but also operators specialization and an optimal patient selection are essential to improve these initial Some procedural challenges need to be overcome prior to the expansion of these techniques to lower risk groups, and time is needed for detailed long-term outcomes and risk estimations. Only with a close collaboration among different specialists, basic researchers and the industry will the future development of transcatheter aortic implantation techniques be ensured.
A meta-analysis of aortic root size in elite athletes.
Iskandar, Aline; Thompson, Paul D
2013-02-19
The aorta is exposed to hemodynamic stress during exercise, but whether or not the aorta is larger in athletes is not clear. We performed a systematic literature review and meta-analysis to examine whethere athletes demonstrate increased aortic root dimensions compared with nonathlete controls. We searched MEDLINE and Scopus from inception through August 12, 2012, for English-language studies reporting the aortic root size in elite athletes. Two investigators independently extracted athlete and study characteristics. A multivariate linear mixed model was used to conduct meta-regression analyses. We identified 71 studies reporting aortic root dimensions in 8564 unique athletes, but only 23 of these studies met our criteria by reporting aortic root dimensions at the aortic valve annulus or sinus of Valsalva in elite athletes (n=5580). Athletes were compared directly with controls (n=727) in 13 studies. On meta-regression, the weighted mean aortic root diameter measured at the sinuses of Valsalva was 3.2 mm (P=0.02) larger in athletes than in the nonathletic controls, whereas aortic root size at the aortic valve annulus was 1.6 mm (P=0.04) greater in athletes than in controls. Elite athletes have a small but significantly larger aortic root diameter at the sinuses of Valsalva and aortic valve annulus, but this difference is minor and clinically insignificant. Clinicians evaluating athletes should know that marked aortic root dilatation likely represents a pathological process and not a physiological adaptation to exercise.
Izgi, Cemil; Nyktari, Evangelia; Alpendurada, Francisco; Bruengger, Annina Studer; Pepper, John; Treasure, Tom; Mohiaddin, Raad
2015-10-15
Personalized external aortic root support (PEARS) is a novel surgical approach with the aim of stabilizing the aortic root size and decreasing risk of dissection in Marfan syndrome patients. A bespoke polymer mesh tailored to each patient's individual aorta shape is produced by modeling and then surgically implanted. The aim of this study is to assess the mechanical effects of PEARS on the aortic root systolic downward motion (an important determinant of aortic wall stress), aortic root distension and on the left ventricle (LV). A cohort of 27 Marfan patients had a prophylactic PEARS surgery between 2004 and 2012 with 24 having preoperative and follow-up cardiovascular magnetic resonance imaging studies. Systolic downward aortic root motion, aortic root distension, LV volumes/mass and mitral annular systolic excursion before the operation and in the latest follow-up were measured randomly and blinded. After a median follow-up of 50.5 (IQR 25.5-72) months following implantation of PEARS, systolic downward motion of aortic root was significantly decreased (12.6±3.6mm pre-operation vs 7.9±2.9mm latest follow-up, p<0.00001). There was a tendency for a decrease in systolic aortic root distension but this was not significant (median 4.5% vs 2%, p=0.35). There was no significant change in LV volumes, ejection fraction, mass and mitral annular systolic excursion in follow-up. PEARS surgery decreases systolic downward aortic root motion which is an important determinant of longitudinal aortic wall stress. Aortic wall distension and Windkessel function are not significantly impaired in the follow-up after implantation of the mesh which is also supported by the lack of deterioration of LV volumes or mass. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.
Atenolol versus Losartan in Children and Young Adults with Marfan's Syndrome
Lacro, R.V.; Dietz, H.C.; Sleeper, L.A.; Yetman, A.T.; Bradley, T.J.; Colan, S.D.; Pearson, G.D.; Tierney, E.S. Selamet; Levine, J.C.; Atz, A.M.; Benson, D.W.; Braverman, A.C.; Chen, S.; De Backer, J.; Gelb, B.D.; Grossfeld, P.D.; Klein, G.L.; Lai, W.W.; Liou, A.; Loeys, B.L.; Markham, L.W.; Olson, A.K.; Paridon, S.M.; Pemberton, V.L.; Pierpont, M.E.; Pyeritz, R.E.; Radojewski, E.; Roman, M.J.; Sharkey, A.M.; Stylianou, M.P.; Wechsler, S. Burns; Young, L.T.; Mahony, L.
2015-01-01
BACKGROUND Aortic-root dissection is the leading cause of death in Marfan's syndrome. Studies suggest that with regard to slowing aortic-root enlargement, losartan may be more effective than beta-blockers, the current standard therapy in most centers. METHODS We conducted a randomized trial comparing losartan with atenolol in children and young adults with Marfan's syndrome. The primary outcome was the rate of aortic-root enlargement, expressed as the change in the maximum aortic-root-diameter z score indexed to body-surface area (hereafter, aortic-root z score) over a 3-year period. Secondary outcomes included the rate of change in the absolute diameter of the aortic root; the rate of change in aortic regurgitation; the time to aortic dissection, aortic-root surgery, or death; somatic growth; and the incidence of adverse events. RESULTS From January 2007 through February 2011, a total of 21 clinical centers enrolled 608 participants, 6 months to 25 years of age (mean [±SD] age, 11.5±6.5 years in the atenolol group and 11.0±6.2 years in the losartan group), who had an aortic-root z score greater than 3.0. The baseline-adjusted rate of change (±SE) in the aortic-root z score did not differ significantly between the atenolol group and the losartan group (−0.139±0.013 and −0.107±0.013 standard-deviation units per year, respectively; P = 0.08). Both slopes were significantly less than zero, indicating a decrease in the degree of aortic-root dilatation relative to body-surface area with either treatment. The 3-year rates of aortic-root surgery, aortic dissection, death, and a composite of these events did not differ significantly between the two treatment groups. CONCLUSIONS Among children and young adults with Marfan's syndrome who were randomly assigned to losartan or atenolol, we found no significant difference in the rate of aortic-root dilatation between the two treatment groups over a 3-year period. (Funded by the National Heart, Lung, and Blood Institute and others; ClinicalTrials.gov number, NCT00429364.) PMID:25405392
Atenolol versus losartan in children and young adults with Marfan's syndrome.
Lacro, Ronald V; Dietz, Harry C; Sleeper, Lynn A; Yetman, Anji T; Bradley, Timothy J; Colan, Steven D; Pearson, Gail D; Selamet Tierney, E Seda; Levine, Jami C; Atz, Andrew M; Benson, D Woodrow; Braverman, Alan C; Chen, Shan; De Backer, Julie; Gelb, Bruce D; Grossfeld, Paul D; Klein, Gloria L; Lai, Wyman W; Liou, Aimee; Loeys, Bart L; Markham, Larry W; Olson, Aaron K; Paridon, Stephen M; Pemberton, Victoria L; Pierpont, Mary Ella; Pyeritz, Reed E; Radojewski, Elizabeth; Roman, Mary J; Sharkey, Angela M; Stylianou, Mario P; Wechsler, Stephanie Burns; Young, Luciana T; Mahony, Lynn
2014-11-27
Aortic-root dissection is the leading cause of death in Marfan's syndrome. Studies suggest that with regard to slowing aortic-root enlargement, losartan may be more effective than beta-blockers, the current standard therapy in most centers. We conducted a randomized trial comparing losartan with atenolol in children and young adults with Marfan's syndrome. The primary outcome was the rate of aortic-root enlargement, expressed as the change in the maximum aortic-root-diameter z score indexed to body-surface area (hereafter, aortic-root z score) over a 3-year period. Secondary outcomes included the rate of change in the absolute diameter of the aortic root; the rate of change in aortic regurgitation; the time to aortic dissection, aortic-root surgery, or death; somatic growth; and the incidence of adverse events. From January 2007 through February 2011, a total of 21 clinical centers enrolled 608 participants, 6 months to 25 years of age (mean [±SD] age, 11.5±6.5 years in the atenolol group and 11.0±6.2 years in the losartan group), who had an aortic-root z score greater than 3.0. The baseline-adjusted rate of change in the mean (±SE) aortic-root z score did not differ significantly between the atenolol group and the losartan group (-0.139±0.013 and -0.107±0.013 standard-deviation units per year, respectively; P=0.08). Both slopes were significantly less than zero, indicating a decrease in the aortic-root diameter relative to body-surface area with either treatment. The 3-year rates of aortic-root surgery, aortic dissection, death, and a composite of these events did not differ significantly between the two treatment groups. Among children and young adults with Marfan's syndrome who were randomly assigned to losartan or atenolol, we found no significant difference in the rate of aortic-root dilatation between the two treatment groups over a 3-year period. (Funded by the National Heart, Lung, and Blood Institute and others; ClinicalTrials.gov number, NCT00429364.).
Fungal Endocarditis Due to Aspergillus oryzae: The First Case Reported in the Literature.
Mazza, Andrea; Luciani, Nicola; Luciani, Marco; Cammertoni, Federico; Giaquinto, Alessia; Pavone, Natalia; Bruno, Piergiorgio; Massetti, Massimo
2017-03-01
Infective endocarditis (IE) is a severe disease with high mortality and morbidity. Prosthetic valve endocarditis is a life-threatening complication which can occur in less than 10% of patients with valve prosthesis. A fungal etiology of IE is rare and accounts for only 2-4% of all case of endocarditis, but is associated with a higher mortality and morbidity. Herein is reported the first case of fungal endocarditis of aortic valve prosthesis due to Aspergillus oryzae in a 67-year-old caucasian man who nine years previously underwent mitral and aortic valve replacement with mechanical prostheses, and tricuspid annuloplasty for acute IE due to Enterococcus spp. Seven months previously, the patient also underwent a redo cardiac procedure to replace a mitral valve prosthesis with a new mechanical device due to a leakage. Aspergillus oryzae showed impressive growth with strong and unexpected virulence in both local and systemic settings.
Immersed boundary-finite element model of fluid-structure interaction in the aortic root
NASA Astrophysics Data System (ADS)
Flamini, Vittoria; DeAnda, Abe; Griffith, Boyce E.
2016-04-01
It has long been recognized that aortic root elasticity helps to ensure efficient aortic valve closure, but our understanding of the functional importance of the elasticity and geometry of the aortic root continues to evolve as increasingly detailed in vivo imaging data become available. Herein, we describe a fluid-structure interaction model of the aortic root, including the aortic valve leaflets, the sinuses of Valsalva, the aortic annulus, and the sinotubular junction, that employs a version of Peskin's immersed boundary (IB) method with a finite element description of the structural elasticity. As in earlier work, we use a fiber-based model of the valve leaflets, but this study extends earlier IB models of the aortic root by employing an incompressible hyperelastic model of the mechanics of the sinuses and ascending aorta using a constitutive law fit to experimental data from human aortic root tissue. In vivo pressure loading is accounted for by a backward displacement method that determines the unloaded configuration of the root model. Our model yields realistic cardiac output at physiological pressures, with low transvalvular pressure differences during forward flow, minimal regurgitation during valve closure, and realistic pressure loads when the valve is closed during diastole. Further, results from high-resolution computations indicate that although the detailed leaflet and root kinematics show some grid sensitivity, our IB model of the aortic root nonetheless produces essentially grid-converged flow rates and pressures at practical grid spacings for the high Reynolds number flows of the aortic root. These results thereby clarify minimum grid resolutions required by such models when used as stand-alone models of the aortic valve as well as when used to provide models of the outflow valves in models of left-ventricular fluid dynamics.
Mechanics of cryopreserved aortic and pulmonary homografts.
Vesely, I; Casarotto, D C; Gerosa, G
2000-01-01
The surgical placement of pulmonary valve grafts into the aortic position (the Ross procedure) has been performed for three decades. Cryopreserved pulmonary valves have had mixed clinical results, however. The objectives of this study were to compare the mechanics of cryopreserved human aortic and pulmonary valve cusps and roots to determine if the pulmonary root can withstand the greater pressures of the aortic position. Six aortic and six pulmonary valve roots were obtained from the Oxford Valve Bank. They were harvested during cardiac transplantation from hearts explanted for dilated cardiomyopathy (mean patient age 68 years). The whole roots were initially stored frozen at -186 degrees C, then shipped packed on dry ice. After complete thawing, the roots were pressurized whole; test strips were then cut from the valve cusps, roots and sinuses and tested for stress/strain, stress relaxation, and ultimate failure strength. The pulmonary roots were more distensible (30% versus 20% strain to lock-up) and less compliant when loaded to aortic pressures. The pulmonary valve cusp and root tissue also showed greater extensibility and greater stiffness (lower compliance) when subjected to the same loads. We conclude that mechanical differences between aortic and pulmonary valve tissues are minimal. The pulmonary root should withstand the forces imposed on it when placed in the aortic position. However, if implanted whole, the pulmonary root will distend about 30% more than the aortic root when subjected to aortic pressures. These geometric changes may affect valve function in the long term and should be appreciated when implanting a pulmonary valve graft.
Beddermann, Christoph; Norman, John C.; Cooley, Denton A.
1979-01-01
Two Jehovah's Witnesses with large ascending thoracic aortic aneurysms and aortic insufficiency secondary to annuloaortic ectasia underwent successful combined replacement of the aortic valve and the ascending aorta. One patient received a composite graft containing an aortic valve prosthesis, which necessitated supravalvular coronary ostia reimplantation; the other patient underwent separate aortic valve and left supracoronary ascending aneurysm replacement, with reimplantation of the right coronary ostium into the graft. No blood or blood derivatives were administered. Both patients had uneventful recoveries and continue to do well. To our knowledge, they represent the first reported cases of successful combined replacement of the aortic valve and ascending aorta in Jehovah's Witnesses. Images PMID:15216324
Gunning, Paul S.; Saikrishnan, Neelakantan; Yoganathan, Ajit P.; McNamara, Laoise M.
2015-01-01
Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a ‘peel-back’ leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve. PMID:26674192
Singh, S D; Xu, X Y; Pepper, J R; Izgi, C; Treasure, T; Mohiaddin, R H
2016-07-05
Aortic root motion was previously identified as a risk factor for aortic dissection due to increased longitudinal stresses in the ascending aorta. The aim of this study was to investigate the effects of aortic root motion on wall stress and strain in the ascending aorta and evaluate changes before and after implantation of personalised external aortic root support (PEARS). Finite element (FE) models of the aortic root and thoracic aorta were developed using patient-specific geometries reconstructed from pre- and post-PEARS cardiovascular magnetic resonance (CMR) images in three Marfan patients. The wall and PEARS materials were assumed to be isotropic, incompressible and linearly elastic. A static load on the inner wall corresponding to the patients' pulse pressure was applied. Cardiovascular MR cine images were used to quantify aortic root motion, which was imposed at the aortic root boundary of the FE model, with zero-displacement constraints at the distal ends of the aortic branches and descending aorta. Measurements of the systolic downward motion of the aortic root revealed a significant reduction in the axial displacement in all three patients post-PEARS compared with its pre-PEARS counterparts. Higher longitudinal stresses were observed in the ascending aorta when compared with models without the root motion. Implantation of PEARS reduced the longitudinal stresses in the ascending aorta by up to 52%. In contrast, the circumferential stresses at the interface between the supported and unsupported aorta were increase by up to 82%. However, all peak stresses were less than half the known yield stress for the dilated thoracic aorta. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pre- and Postoperative Imaging of the Aortic Root
Chan, Frandics P.; Mitchell, R. Scott; Miller, D. Craig; Fleischmann, Dominik
2016-01-01
Three-dimensional datasets acquired using computed tomography and magnetic resonance imaging are ideally suited for characterization of the aortic root. These modalities offer different advantages and limitations, which must be weighed according to the clinical context. This article provides an overview of current aortic root imaging, highlighting normal anatomy, pathologic conditions, imaging techniques, measurement thresholds, relevant surgical procedures, postoperative complications and potential imaging pitfalls. Patients with a range of clinical conditions are predisposed to aortic root disease, including Marfan syndrome, bicuspid aortic valve, vascular Ehlers-Danlos syndrome, and Loeys-Dietz syndrome. Various surgical techniques may be used to repair the aortic root, including placement of a composite valve graft, such as the Bentall and Cabrol procedures; placement of an aortic root graft with preservation of the native valve, such as the Yacoub and David techniques; and implantation of a biologic graft, such as a homograft, autograft, or xenograft. Potential imaging pitfalls in the postoperative period include mimickers of pathologic processes such as felt pledgets, graft folds, and nonabsorbable hemostatic agents. Postoperative complications that may be encountered include pseudoaneurysms, infection, and dehiscence. Radiologists should be familiar with normal aortic root anatomy, surgical procedures, and postoperative complications, to accurately interpret pre- and postoperative imaging performed for evaluation of the aortic root. Online supplemental material is available for this article. ©RSNA, 2015 PMID:26761529
The Mosaic bioprosthesis in the aortic position: 17 years' results.
Gansera, Brigitte; Hapfelmeier, Alexander; Brandl, Kristina; Spiliopoulos, Kyriakos; Gundling, Felix; Eichinger, Walter
2014-02-01
The Mosaic bioprosthesis (Medtronic Inc., Minneapolis, Minnesota, United States), a stented porcine aortic valve, combines glutaraldehyde fixation with zero-pressure, root-pressure techniques and antimineralization treatment with amino-oleic acid for improved hemodynamics and tissue durability. The first device has been implanted worldwide at the authors' institution in September 1993. The aim of the present study was to collect mid- to long-term data of the prosthesis. A total of 272 patients (124 males and 148 females) underwent isolated aortic valve replacement with the Mosaic bioprosthesis between September 1993 and August 2007. Median age at implant was 76.8 years (range, 31.3 to 90.7). Median follow-up was 12.0 years (range, 0 to 17.2 years); follow-up was complete for 223 (82%) patients. Early mortality (30 days) was 4% (12 patients). Overall survival at 5, 10, 15, and 17 years was 68.6% ± 3.1%, 36.4% ± 3.3%, 17.1% ± 3.6%, and 10.7% ± 4.3%, respectively. Eleven late deaths (5%) were cardiac related. There were 24 thromboembolic events, 1 hemorrhagic, and 6 reoperations/explants. At a median follow-up of 12 years, freedom from any cause of death was 27.0% ± 3.2% acting as a competing risk for the incidence of thromboembolic events (16.4% ± 3.5%), hemorrhage (0.5% ± 0.5%), and reoperation/explant (4.1% ± 1.8%). Two redos were due to structural valve deterioration (SVD), two for nonstructural dysfunction (paravalvular leakage), one for thrombosed prosthesis, and one for endocarditis. Performance and late outcome of the Mosaic bioprosthesis was satisfactory during 17 years after clinical introduction. The Mosaic bioprosthesis showed low incidence of SVD or need for reoperation in the long term. Georg Thieme Verlag KG Stuttgart · New York.
Computer-aided design of the human aortic root.
Ovcharenko, E A; Klyshnikov, K U; Vlad, A R; Sizova, I N; Kokov, A N; Nushtaev, D V; Yuzhalin, A E; Zhuravleva, I U
2014-11-01
The development of computer-based 3D models of the aortic root is one of the most important problems in constructing the prostheses for transcatheter aortic valve implantation. In the current study, we analyzed data from 117 patients with and without aortic valve disease and computed tomography data from 20 patients without aortic valvular diseases in order to estimate the average values of the diameter of the aortic annulus and other aortic root parameters. Based on these data, we developed a 3D model of human aortic root with unique geometry. Furthermore, in this study we show that by applying different material properties to the aortic annulus zone in our model, we can significantly improve the quality of the results of finite element analysis. To summarize, here we present four 3D models of human aortic root with unique geometry based on computational analysis of ECHO and CT data. We suggest that our models can be utilized for the development of better prostheses for transcatheter aortic valve implantation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhu, Da; Chen, Yucheng; Guo, Yingqiang; Hu, Jia; Zhang, Ji; Wei, Xin; Tang, Hong; Shi, Yingkang
2015-11-15
To evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis (AS) or pure/dominant aortic regurgitation (AR) using the J-Valve™ system. Twenty patients with isolated aortic valve disease (11 with pure/dominant AR and 9 with AS) at high risk for open-heart surgery were enrolled in this study. The mean Logistic Euro-SCORE I was 27.2±8.2% (mean age 74.5±4.7years). Four sizes of prosthesis were used for annular size up to 21 mm (n=1), 23mm (n=2), 25mm (n=10) and 27mm (n=7). Clinical and echocardiographic evaluations were performed at baseline, post-procedure and follow-up. The primary endpoint was all-cause mortality. Secondary endpoints were procedural success, major adverse events as well as echocardiographic performance. TAVI with the J-Valve™ device was successfully performed in 19 patients (95%). Conversion to surgical valve replacement was necessary in one patient due to prosthesis embolization. No mortality occurred during 90 days follow-up. Pacemaker implantation for new onset conduction disorders was necessary in one patient (5%). For patient with severe AS, post-procedure TAVI resulted in favorable reduction of mean transvalvular gradients (55.3±8.5 vs. 16.4±13.3 mmHg, P<0.01). Mean transvalvular gradient was also favorable in AR patients after valve implantation (6.9±1mmHg). The majority of patients had none or trivial paravalvular regurgitation (17/19) while none had moderate or severe paravalvular regurgitation. Trans-apical TAVI using the J-Valve™ prosthesis is potentially an effective treatment option for patients with AS or pure/dominant AR at high risk for open-heart surgery. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
First uses of HAART 300 rings for aortic valve repair in Poland - 4 case studies.
Juściński, Jacek H; Koprowski, Andrzej; Kołaczkowska, Magdalena; Kowalik, Maciej M; Rogowski, Jan A; Rankin, James S
2018-03-01
Aortic valve reconstructions using geometric annuloplasty rings HAART 300/200 open new era in aortic valve surgery. The HAART technology resizes, reshapes, stabilizes and simplifies aortic valve repair. The HAART aortic repair rings are designed to be implanted directly into aortic annulus (under aortic valve leaflets). We present first in Poland 4 cases of aortic valve reconstructions using geometric annuloplasty rings HAART 300. Two patients had type IA aortic insufficiency (due to El-Khoury classification) - they were treated by HAART 300 ring insertion and ascending aorta prosthesis implantation. Third patient, Marfan with type IB aortic insufficiency was repaired by HAART 300 ring implantation followed by remodeling (Yacoub) procedure. Fourth patient with type II aortic insufficiency (due to RCC prolapse) was repaired by HAART 300 implantation and cusp plication. All patients shows good results on 6 months postoperative 3D TTE examinations. Presented technique is reproducible and simplify aortic valve reconstructions.
Kon, Neal D; Riley, Robert D; Adair, Sandy M; Kitzman, Dalane W; Cordell, A Robert
2002-06-01
Stentless porcine aortic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation, and perhaps improved durability. One hundred four patients were operated on from September 17, 1992, to October 31, 1997, as part of a multicenter worldwide investigation of the Medtronic Freestyle stentless porcine bioprosthesis. All patients received a total aortic root replacement. The patients were evaluated postoperatively at discharge, at 3 to 6 months, and yearly by clinical examination and color flow Doppler echocardiography. Operative mortality was 3.9%. No patient experienced structural valve deterioration, nonstructural deterioration, perivalvular leak, or unacceptable hemodynamic performance. At 8 years, survival was 59.8%. Freedom from thromboembolic complications was 83.3%. Freedom from postoperative endocarditis was 96.9%. Freedom from reoperation was 100%. Mean systolic gradients did not change over the time period studied. They were 6.4 +/- 3.8 mm Hg at 1 year and 6.7 +/- 2.6 mm Hg at 8 years. Correspondingly, effective orifice area was 1.9 +/- 0.7 cm2 at 1 year and 1.8 +/- 0.8 cm2 at 8 years. The incidence of any aortic insufficiency also did not change over the length of follow-up. At 1 year, 98% of patients had no or trivial aortic insufficiency and 2% had mild aortic insufficiency. At 8 years, 100% of patients evaluated were free of any aortic insufficiency. The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root or aortic valve for aortic valve and aortic root pathology. Total root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Results up to 8 years show excellent survival and no signs of degeneration. Further follow-up is still needed to determine valve durability.
NASA Astrophysics Data System (ADS)
Abbas, S. S.; Nasif, M. S.; Said, M. A. M.; Kadhim, S. K.
2017-10-01
Structural stresses developed in an artificial bileaflet mechanical heart valve (BMHV) due to pulsed blood flow may cause valve failure due to yielding. In this paper, von-Mises stresses are computed and compared for BMHV placed in two types of aortic root geometries that are aortic root with axisymmetric sinuses and with axisymmetric bulb, at different physiological blood flow rates. With BMHV placed in an aortic root with axisymmetric sinuses, the von-Mises stresses developed in the valve were found to be up to 47% higher than BMHV placed in aortic root with axisymmetric bulb under similar physiological conditions. High velocity vectors and therefore high von-Mises stresses have been observed for BMHV placed in aortic root with axisymmetric sinuses, that can lead to valve failure.
Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation.
Vy, Phuoc; Auffret, Vincent; Castro, Miguel; Badel, Pierre; Rochette, Michel; Haigron, Pascal; Avril, Stéphane
2018-06-01
Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation). Copyright © 2018 John Wiley & Sons, Ltd.
Kherada, Nisharahmed; Brenes, Juan Carlos; Kini, Annapoorna S; Dangas, George D
2017-03-15
Accurate evaluation of trans-aortic valvular pressure gradients is challenging in cases where dual mechanical aortic and mitral valve prostheses are present. Non-invasive Doppler echocardiographic imaging has its limitations due to multiple geometric assumptions. Invasive measurement of trans-valvular gradients with cardiac catheterization can provide further information in patients with two mechanical valves, where simultaneous pressure measurements in the left ventricle and ascending aorta must be obtained. Obtaining access to the left ventricle via the mitral valve after a trans-septal puncture is not feasible in the case of a concomitant mechanical mitral valve, whereas left ventricular apical puncture technique is associated with high procedural risks. Retrograde crossing of a bileaflet mechanical aortic prosthesis with standard catheters is associated with the risk of catheter entrapment and acute valvular regurgitation. In these cases, the assessment of trans-valvular gradients using a 0.014˝ diameter coronary pressure wire technique has been described in a few case reports. We present the case of a 76-year-old female with rheumatic valvular heart disease who underwent mechanical aortic and mitral valve replacement in the past. She presented with decompensated heart failure and echocardiographic findings suggestive of elevated pressure gradient across the mechanical aortic valve prosthesis. The use of a high-fidelity 0.014˝ diameter coronary pressure guidewire resulted in the detection of a normal trans-valvular pressure gradient across the mechanical aortic valve. This avoided a high-risk third redo valve surgery in our patient. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Masri, Ahmad; Kalahasti, Vidyasagar; Svensson, Lars G; Roselli, Eric E; Johnston, Douglas; Hammer, Donald; Schoenhagen, Paul; Griffin, Brian P; Desai, Milind Y
2016-11-29
In patients with a dilated proximal ascending aorta and trileaflet aortic valve, we aimed to assess (1) factors independently associated with increased long-term mortality and (2) the incremental prognostic utility of indexing aortic root to patient height. We studied consecutive patients with a dilated aortic root (≥4 cm) that underwent echocardiography and gated contrast-enhanced thoracic aortic computed tomography or magnetic resonance angiography between 2003 and 2007. A ratio of aortic root area over height was calculated (cm 2 /m) on tomography, and a cutoff of 10 cm 2 /m was chosen as abnormal, on the basis of previous reports. All-cause death was recorded. The cohort comprised 771 patients (63 years [interquartile range, 53-71], 87% men, 85% hypertension, 51% hyperlipidemia, 56% smokers). Inherited aortopathies, moderate to severe aortic regurgitation, and severe aortic stenosis were seen in 7%, 18%, and 2%, whereas 91% and 54% were on β-blockers and angiotensin-converting enzyme inhibitors, respectively. Aortic root area/height ratio was ≥10 cm 2 /m in 24%. The Society of Thoracic Surgeons score and right ventricular systolic pressure were 3.3±3 and 31±7 mm Hg, respectively. At 7.8 years (interquartile range, 6.6-8.9), 280 (36%) patients underwent aortic surgery (76% within 1 year) and 130 (17%) died (1% in-hospital postoperative mortality). A lower proportion of patients in the surgical (versus nonsurgical) group died (13% versus 19%, P<0.01). On multivariable Cox proportional hazard analysis, aortic root area/height ratio (hazard ratio, 4.04; 95% confidence interval [CI], 2.69-6.231) was associated with death, whereas aortic surgery (hazard ratio, 0.47; 95% CI, 0.27-0.81) was associated with improved survival (both P<0.01). For longer-term mortality, the addition of aortic root area/height ratio ≥10 cm 2 /m to a clinical model (Society of Thoracic Surgeons score, inherited aortopathies, hypertension, hyperlipidemia, medications, aortic regurgitation, and right ventricular systolic pressure), increased the c-statistic from 0.57 (95% CI, 0.35-0.77) to 0.65 (95% CI, 0.52-0.73) and net reclassification index from 0.17 (95% CI, 0.02-0.31) to 0.23 (95% CI, 0.04-0.34), both P<0.01. Of the 327 patients with aortic root diameter between 4.5 and 5.5 cm, 44% had an abnormal aortic root area/height ratio, of which 78% died. In patients with dilated aortic root and trileaflet aortic valve, a ratio of aortic root area to height provides independent and improved stratification for prediction of death. © 2016 American Heart Association, Inc.
Dankerl, Peter; Hammon, Matthias; Seuss, Hannes; Tröbs, Monique; Schuhbaeck, Annika; Hell, Michaela M; Cavallaro, Alexander; Achenbach, Stephan; Uder, Michael; Marwan, Mohamed
2017-05-01
To evaluate the performance of computer-aided evaluation software for a comprehensive workup of patients prior to transcatheter aortic valve implantation (TAVI) using low-contrast agent and low radiation dose third-generation dual-source CT angiography. We evaluated 30 consecutive patients scheduled for TAVI. All patients underwent ECG-triggered high-pitch dual-source CT angiography of the aortic root and aorta with a standardized contrast agent volume (30 ml Imeron350, flow rate 4 ml/s) and low-dose (100 kv/350 mAs) protocol. An expert (10 years of experience) manually evaluated aortic root and iliac access dimensions (distance between coronary ostia and aortic annulus, minimal/maximal diameters and area-derived diameter of the aortic annulus) and best CT-predicted fluoroscopic projection angle as the reference standard. Utilizing computer-aided software (syngo.via), the same pre-TAVI workup was performed and compared to the reference standard. Mean CTDI[Formula: see text] was 3.46 mGy and mean DLP 217.6 ± 12.1 mGy cm, corresponding to a mean effective dose of 3.7 ± 0.2 mSv. Computer-aided evaluation was successful in all but one patient. Compared to the reference standard, Bland-Altman analysis indicated very good agreement for the distances between aortic annulus and coronary ostia (RCA: mean difference 0.8 mm; 95 % CI 0.4-1.2 mm; LM: mean difference 0.9 mm; 95 % CI 0.5-1.3 mm); however, we demonstrated a systematic overestimation of annulus- derived diameter using the software (mean difference 44.4 mm[Formula: see text]; 95 % CI 30.4-58.3 mm[Formula: see text]). Based on respective annulus dimensions, the recommended prosthesis size (Edwards SAPIEN 3) matched in 26 out of the 29 patients (90 %). CT-derived fluoroscopic projection angles showed an excellent agreement for both methods. Out of 58 iliac arteries, 15 (25 %) arteries could not be segmented by the software. Preprocessing time of the software was 71 ± 11 s (range 51-96 s), and reading time with the software was 118 ± 31 s (range 68-201 s). In the workup of pre-TAVI CT angiography, computer-aided evaluation of low-contrast, low-dose examinations is feasible with good agreement and quick reading time. However, a systematic overestimation of the aortic annulus area is observed.
A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation.
Kempfert, Jörg; Rastan, Ardawan J; Schuler, Gerhard; Linke, Axel; Holzhey, David; van Linden, Arnaud; Mohr, Friedrich-W; Walther, Thomas
2011-07-01
Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN™ prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN™ valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a second prosthesis within the first one. Results of this 'bailout' maneuver have not been reported yet. Of 305 TA-AVI procedures, 15 patients required a second prosthesis due to dysfunctional leaflets (n = 6), low position (n = 7), or VSD (n = 2). Mean age was 82.5 ± 1.3 years, mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 45.5 ± 5.4, and Society of Thoracic Surgeons (STS) Score was 13.5 ± 1.5. All second SAPIEN™ valves could be implanted successfully within the first one. The second prosthesis solved leaflet dysfunction, sealed the VSD (lower position of the second prosthesis), or corrected the initial misplacement (higher position of the second prosthesis) in all patients. Within 30 days, four patients died (low cardiac output n = 3, all with preoperative ejection fraction (EF) <35%; intestinal ischemia n = 1). Intra-operative echocardiogram and angiogram revealed mild paravalvular leak in three and none/trace in 12 patients. Transvalvular gradients were low despite the implantation of the second valve (P(max)/mean 13.7 ± 4.3/6.4 ± 2.0). Placement of a second SAPIEN™ valve is a valuable 'bailout' technique in case of VSD, dysfunctional leaflets, or too low placement of the first prosthesis. The technique leads to an excellent functional result with low transvalvular gradients. The simple, straight, tubular stent design of the SAPIEN™ prosthesis may be the ideal design for such valve-in-valve procedures. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Cruz, Cristina; Pinho, Teresa; Lebreiro, Ana; Silva Cardoso, José; Maciel, Maria Júlia
2013-06-01
Transthoracic echocardiography is an important tool after tetralogy of Fallot repair, of which aortic root dilatation is a recognized complication. In this study we aimed to assess its prevalence and potential predictors. We consecutively assessed adult patients by transthoracic echocardiography after tetralogy of Fallot repair, and divided them into two groups based on the maximum internal aortic diameter at the sinuses of Valsalva in parasternal long-axis view: group 1 with aortic root dilatation (≥38 mm) and group 2 without dilatation (<38 mm). A total of 53 patients were included, mean age 32±10 years, with a mean time since surgery of 23±7 years. An aortopulmonary shunt had been performed prior to complete repair in 25 patients, and a transannular patch was used in 19 patients. Aortic root measurement was possible in all patients. Aortic root dilatation was identified in eight patients (15%), all male. Male gender (p=0.001), body surface area (1.93±0.10 vs. 1.70±0.20 m(2), p=0.03) and increased left ventricular end-diastolic diameter (p=0.005) were predictors of aortic root dilatation. None of the surgical variables studied were predictors of aortic root dilatation. The prevalence of aortic root dilatation in this cohort was low and male gender was a predictor of its occurrence. The type of repair and time to surgery did not influence its occurrence. Quantification of aortic root diameter is possible by transthoracic echocardiography; we suggest indexing it to body surface area in clinical practice. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A
2014-05-01
The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.
Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?
Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim
2004-11-01
Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.
Sripathi, Vangipuram Canchi; Kumar, Ramarathnam Krishna; Balakrishnan, Komarakshi R
2004-03-01
This study aims to find the fundamental differences in the mechanism of opening and closing of a normal aortic valve and a valve with a stiff root, using a dynamic finite element model. A dynamic, finite element model with time varying pressure was used in this study. Shell elements with linear elastic properties for the leaflet and root were used. Two different cases were analyzed: (1) normal leaflets inside a compliant root, and (2) normal leaflets inside a stiff root. A compliant aortic root contributes substantially to the smooth and symmetrical leaflet opening with minimal gradients. In contrast, the leaflet opening inside a stiff root is delayed, asymmetric, and wrinkled. However, this wrinkling is not associated with increased leaflet stresses. In compliant roots, the effective valve orifice area can substantially increase because of increased root pressure and transvalvular gradients. In stiff roots this effect is strikingly absent. A compliant aortic root contributes substantially to smooth and symmetrical leaflet opening with minimal gradients. The compliance also contributes much to the ability of the normal aortic valve to increase its effective valve orifice in response to physiologic demands of exercise. This effect is strikingly absent in stiff roots.
Hanania, G; Michel, P L; Montély, J M; Warembourg, H; Nardi, O; Leguerrier, A; Agnino, A; Despins, P; Legault, B; Petit, H; Bouraindeloup, M
2004-01-01
the aim of this study was to document the choice between prosthesis and bioprosthesis in cases of valvular replacement during the seventh decade of life. a retrospective and cooperative study linking eleven cardiac surgical teams and five medical cardiology teams combined 497 subjects born between 1915 and 1925 (average age 64.4 years) who underwent aortic (313 cases) or mitral (184 cases) valvular replacement with mechanical prosthesis (259 cases) or bioprosthesis (238 cases). Information was collected at each centre during the year 2000 on the long term evolution (going back 15 years), in particular on the mortality, non-fatal complications linked to the valve, cardiac complications and extra-cardiac events. These results were subjected to statistical analysis. the operative mortality of this group was 4.8%. The 15 year survival was 46% for the aortic mechanical prostheses, 32% for the aortic bioprostheses (p=0.04). 34% for the mitral bioprostheses and 33% for the mitral mechanical prostheses. Events linked to the valve were more frequent for the mitral valvulopathies than for the aortic valves (49% vs 26%, p<0.001). The absence of events linked to the valve at 15 years was 69% for the aortic mechanical prostheses and 68% for the aortic bioprostheses. This was the case in only 57% of mitral mechanical prostheses and 36% of the mitral bioprostheses (p=0.11). Thromboembolic accidents were three times more frequent in the mitrals than in the aortics (11.5 vs 3.8%, p=0.002). Haemorrhage was four times more frequent for the mechanical prostheses than for the bioprostheses (7.7 vs 2%, p=0.01). The risk of degeneration for the aortic bioprostheses was 20% at 15 years, three times less so after 65 years of age (p=0.03). At 48% it was much higher in the mitral valves at 15 years with no significant difference before and after 65 years of age (p=0.3). the current life expectancy of subjects in their seventh decade is important. The greatly elevated risk of bioprosthesis degeneration in the mitral position does not allow this alternative to be advocated before 70 years of age. In the aortic position, this risk is elevated before 65 years of age. It is lower after 65 years old. Nevertheless, this means the risk of reoperation in certain octogenarians must be accepted, balanced with the linear risk of haemorrhagic accidents for which a future reduction is expected thanks to milder anticoagulation for aortic mechanical prostheses and anticoagulation autocontrol.
Elahi, Maqsood M; Choi, Charles H; Konda, Subbareddy; Shake, Jay G
2015-01-01
This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical prosthesis. Nattokinase is an enzyme derived from a popular fermented soybean preparation in Japan (natto), which has fibrinolytic properties and is gaining popularity in nontraditional health journals and nonmedical health websites as an over-the-counter thrombolytic. After nearly a year of use of nattokinase without warfarin, the patient developed thrombus on the mechanical valve and underwent successful repeat valve replacement. We believe this is the first documented case of nattokinase being used as a substitute for warfarin after valve replacement, and we strongly discourage its use for this purpose.
Elahi, Maqsood M.; Choi, Charles H.; Konda, Subbareddy
2015-01-01
This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical prosthesis. Nattokinase is an enzyme derived from a popular fermented soybean preparation in Japan (natto), which has fibrinolytic properties and is gaining popularity in nontraditional health journals and nonmedical health websites as an over-the-counter thrombolytic. After nearly a year of use of nattokinase without warfarin, the patient developed thrombus on the mechanical valve and underwent successful repeat valve replacement. We believe this is the first documented case of nattokinase being used as a substitute for warfarin after valve replacement, and we strongly discourage its use for this purpose. PMID:25552810
Impact of aortic root size on left ventricular afterload and stroke volume.
Sahlén, Anders; Hamid, Nadira; Amanullah, Mohammed Rizwan; Fam, Jiang Ming; Yeo, Khung Keong; Lau, Yee How; Lam, Carolyn S P; Ding, Zee Pin
2016-07-01
The left ventricle (LV) ejects blood into the proximal aorta. Age and hypertension are associated with stiffening and dilation of the aortic root, typically viewed as indicative of adverse remodeling. Based on analytical considerations, we hypothesized that a larger aortic root should be associated with lower global afterload (effective arterial elastance, EA) and larger stroke volume (SV). Moreover, as antihypertensive drugs differ in their effect on central blood pressure, we examined the role of antihypertensive drugs for the relation between aortic root size and afterload. We studied a large group of patients (n = 1250; 61 ± 12 years; 78 % males; 64 % hypertensives) from a single-center registry with known or suspected coronary artery disease. Aortic root size was measured by echocardiography as the diameter of the tubular portion of the ascending aorta. LV outflow tract Doppler was used to record SV. In the population as a whole, after adjusting for key covariates in separate regression models, aortic root size was an independent determinant of both SV and EA. This association was found to be heterogeneous and stronger in patients taking a calcium channel blocker (CCB; 10.6 % of entire population; aortic root size accounted for 8 % of the explained variance of EA). Larger aortic root size is an independent determinant of EA and SV. This association was heterogeneous and stronger in patients on CCB therapy.
Aortic root surgery in the United States: a report from the Society of Thoracic Surgeons database.
Stamou, Sotiris C; Williams, Mathew L; Gunn, Tyler M; Hagberg, Robert C; Lobdell, Kevin W; Kouchoukos, Nicholas T
2015-01-01
The purpose of the present study was to evaluate the early clinical outcomes of aortic root surgery in the United States. The Society of Thoracic Surgeons database was queried to identify all patients who had undergone aortic root replacement from 2004 to early 2010 (n = 13,743). The median age was 58 years (range, 18-96); 3961 were women (29%) and 12,059 were white (88%). The different procedures included placement of a mechanical valve conduit (n = 4718, 34%), stented pericardial (n = 879, 6.4%) or porcine (n = 478, 3.5%) bioprosthesis, stentless root (n = 4309, 31%), homograft (n = 498, 3.6%), and valve sparing root replacement (n = 1918, 14%). The median number of aortic root surgeries per site was 2, and only 5% of sites performed >16 aortic root surgeries annually. An increased trend to use biostented (porcine or pericardial) valves during the study period (7% in 2004 vs 14% in 2009). The operative (raw) mortality was greater among the patients with aortic stenosis (6.2%) who had undergone aortic root replacement, independent of age. Mortality was greater in patients who had undergone concomitant valve or coronary artery bypass grafting or valve surgery (21%). The lowest operative mortality was observed in patients who had undergone aortic valve sparing procedures (1.9%). Most cardiac centers performed aortic root surgery in small volumes. The unadjusted operative mortality was greater for patients >80 years old and those with aortic stenosis, regardless of age. Valve sparing root surgery was associated with the lowest mortality. A trend was seen toward an increased use of stented tissue valves from 2004 to 2009. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Associations of Age and Sex with Marfan Phenotype: The NHLBI GenTAC Registry
Roman, Mary J.; Devereux, Richard B.; Preiss, Liliana R.; Asch, Federico M.; Eagle, Kim A.; Holmes, Kathryn W.; LeMaire, Scott A.; Maslen, Cheryl L.; Milewicz, Dianna M.; Morris, Shaine A.; Prakash, Siddharth K.; Pyeritz, Reed E.; Ravekes, William J.; Shohet, Ralph V.; Song, Howard K.; Weinsaft, Jonathan W.
2017-01-01
Background The associations of age and sex with phenotypic features of Marfan syndrome have not been systematically examined in a large cohort of both children and adults. Methods and Results We evaluated 789 Marfan patients enrolled in the NHLBI GenTAC Registry (53% male; mean age 31 [range: 1–86 years]). Females aged≥15 and males aged≥16 years were considered adults based on average age of skeletal maturity. Adults (n=606) were more likely than children (n=183) likely to have spontaneous pneumothorax, scoliosis, and striae, but were comparable in revised Ghent systemic score, ectopia lentis, and most phenotypic features, including prevalence of aortic root dilatation. Prophylactic aortic root replacement and mitral valve surgery were rare during childhood vs. adulthood (2 vs. 35% and 1 vs. 9%, respectively, both p<0.0001). Adult males were more likely than females to have aortic root dilatation (92 vs. 84%), aortic regurgitation (55 vs. 36%) and to have undergone prophylactic aortic root replacement (47 vs. 24%), all p<0.001. Prevalence of prior aortic dissection tended to be higher in males than females (25 vs. 18%, p=0.06); 44% of dissections were type B. Type B dissection was strongly associated with previous prophylactic aortic root replacement. Conclusions Pulmonary, skeletal and aortic complications, but not other phenotypic features, are more prevalent in adults than children in Marfan syndrome. Aortic aneurysms and prophylactic aortic surgery are more common in men. Aortic dissection, commonly type B, occurs in an appreciable proportion of Marfan patients, especially in men and following previous prophylactic aortic root replacement. PMID:28600386
Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.
Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V
1992-02-01
From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.
Maeda, Koichi; Kuratani, Toru; Torikai, Kei; Shimamura, Kazuo; Mizote, Isamu; Ichibori, Yasuhiro; Takeda, Yasuharu; Daimon, Takashi; Nakatani, Satoshi; Nanto, Shinsuke; Sawa, Yoshiki
2013-07-01
Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR. Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR. Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060). The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE. © 2013 Wiley Periodicals, Inc.
Adapting to living with a mechanical aortic heart valve: a phenomenographic study.
Oterhals, Kjersti; Fridlund, Bengt; Nordrehaug, Jan Erik; Haaverstad, Rune; Norekvål, Tone M
2013-09-01
To describe how patients adapt to living with a mechanical aortic heart valve. Aortic valve replacement with a mechanical prosthesis is preferred for patients with life expectancy of more than 10 years as they are more durable than bioprosthetic valves. Mechanical valves have some disadvantages, such as higher risk of thrombosis and embolism, increased risk of bleeding related to lifelong oral anticoagulation treatment and noise from the valve. An explorative design with a phenomenographic approach was employed. An explorative design with a phenomenographic approach was applied. Interviews were conducted over 4 months during 2010-2011 with 20 strategically sampled patients, aged 24-74 years having undergone aortic valve replacement with mechanical prosthesis during the last 10 years. Patients adapted to living with a mechanical aortic heart valve in four ways: 'The competent patient' wanted to stay in control of his/her life. 'The adjusted patient' considered the implications of having a mechanical aortic valve as part of his/her daily life. 'The unaware patient' was not aware of warfarin-diet-medication interactions. 'The worried patient' was bothered with the oral anticoagulation and annoyed by the sound of the valve. Patients moved between the different ways of adapting. The oral anticoagulation therapy was considered the most troublesome consequence, but also the sound of the valve was difficult to accept. Patient counselling and adequate follow-up can make patients with mechanical aortic heart valves more confident and competent to manage their own health. We recommend that patients should participate in a rehabilitation programme following cardiac surgery. © 2013 Blackwell Publishing Ltd.
Koos, Ralf; Mahnken, Andreas Horst; Dohmen, Guido; Brehmer, Kathrin; Günther, Rolf W; Autschbach, Rüdiger; Marx, Nikolaus; Hoffmann, Rainer
2011-07-15
This study sought to examine a possible relationship between the severity of aortic valve calcification (AVC), the distribution of AVC and the degree of aortic valve regurgitation (AR) after transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS). 57 patients (22 men, 81 ± 5 years) with symptomatic AS and with a logistic EuroSCORE of 24 ± 12 were included. 38 patients (67%) received a third (18F)-generation CoreValve® aortic valve prosthesis, in 19 patients (33%) an Edwards SAPIEN™ prosthesis was implanted. Prior to TAVI dual-source computed tomography for assessment of AVC was performed. To determine the distribution of AVC the percentage of the calcium load of the most severely calcified cusp was calculated. After TAVI the degree of AR was determined by angiography and echocardiography. The severity of AR after TAVI was related to the severity and distribution of AVC. There was no association between the distribution of AVC and the degree of paravalvular AR after TAVI as assessed by angiography (r = -0.02, p = 0.88). Agatston AVC scores were significantly higher in patients with AR grade ≥ 3 (5055 ± 1753, n = 3) than in patients with AR grade < 3 (1723 ± 967, p = 0.03, n = 54). Agatston AVC scores > 3000 were associated with a relevant paravalvular AR and showed a trend for increased need for second manoeuvres. There was a significant correlation between the severity of AVC and the degree of AR after AVR (r = 0.50, p < 0.001). Patients with severe AVC have an increased risk for a relevant AR after TAVI as well as a trend for increased need for additional procedures. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Crowhurst, James A; Poon, Karl K; Murdoch, Dale; Incani, Alexander; Raffel, Owen C; Liddicoat, Annelise; Walters, Darren
2015-12-01
Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.
Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.
Bleiziffer, Sabine; Hettich, Ina; Hutter, Andrea; Wagner, Anke; Deutsch, Marcus-André; Piazza, Nicolo; Lange, Rüdiger
2013-05-01
The study aim was to investigate the incidence of patient-prosthesis mismatch (PPM) with new catheter valves, and its influence on the patients' clinical state. At present, few echocardiographic data are available on the incidence and impact of PPM with the CoreValve and Sapien prostheses for transcatheter aortic valve implantation (TAVI). The reliability of effective orifice area (EOA) measurements was assured by awaiting an interval of six months after TAVI. Of 256 survivors after TAVI, 149 complete echocardiographic data sets were available for the assessment of the indexed EOA (iEOA). In total, 106 CoreValve prostheses and 43 Sapien prostheses were implanted in this high-risk cohort (mean age 81 +/- 6 years, mean logistic EuroSCORE 20 +/- 13%). The overall incidence of PPM (iEOA < 0.85 cm2/m2) was 61%. Patients with a larger body surface area were more likely to develop PPM (p = 0.001), while the prosthesis type, native annulus diameter, preoperative EOA, gender and prosthesis size had no influence. The mean aortic gradient was significantly higher in patients with PPM. A reduction in the left ventricular end-diastolic diameter was seen in all patients, without significant differences between groups. There were no differences in postoperative NYHA class or self-assessed health state between patients with or without PPM. PPM was common after TAVI in the presented cohort, presumably because the native calcium masses narrow the outflow area available for blood flow. As expected for low gradients, there was no impairment of left ventricular dimension regression or clinical state of the patients, even if severe PPM was present. Based on the presented data, it is assumed that PPM might be less relevant in TAVI patients.
Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis
2017-05-01
Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.
Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.
Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas
2017-06-01
Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.
Reynolds, Matthew R.; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A.; Magnuson, Elizabeth A.; Galper, Benjamin Z.; Meduri, Christopher U.; Arnold, Suzanne V.; Baron, Suzanne J.; Reardon, Michael J.; Adams, David H.; Popma, Jeffrey J.; Cohen, David J.
2016-01-01
Background Prior studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. Objectives The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. Methods We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk pivotal trial. Empirical data regarding survival and quality of life (QOL) over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. perspective. Results Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month QOL. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years (QALYs; 0.41 life-years [LYs]) with 3% discounting. Lifetime incremental cost-effectiveness ratios (ICERs) were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ~$1,650 would lead to an ICER <$50,000/QALY gained. Conclusions In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. standards. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. PMID:26764063
Preservation of the bicuspid aortic valve.
Schäfers, Hans-Joachim; Aicher, Diana; Langer, Frank; Lausberg, Henning F
2007-02-01
Bicuspid anatomy of the aortic valve is a common reason for aortic regurgitation and is associated with aortic dilatation in more than 50% of patients. We have observed different patterns of aortic dilatation and used different approaches preserving the valve. Between October 1995 and February 2006, a regurgitant bicuspid valve was repaired in 173 patients. The aorta was normal in 57 patients who underwent isolated repair. Aortic dilatation mainly above commissural level (n = 38) was treated by separate valve repair plus supracommissural aortic replacement. In 78 patients, aortic dilatation involved the root and was treated by root remodeling. Hospital mortality and perioperative morbidity were low in all three groups. Myocardial ischemia was significantly shorter in repair plus aortic replacement than remodeling (p < 0.001). Freedom from aortic regurgitation II or greater at 5 years varied between 91% and 96%. Freedom from reoperation at 5 years was 97% after remodeling, but only 53% after repair plus aortic replacement (p = 0.33). Symmetric prolapse was the most frequent cause for reoperation. The long-term stability of bicuspid aortic valve repair is excellent in the absence of aortic pathology. In the presence of aortic dilatation, root remodeling leads to equally stable valve durability. In patients with less pronounced root dilatation, separate valve repair plus aortic replacement may be a less complex alternative. Symmetric prolapse should be avoided if the ascending aorta is replaced.
Girdauskas, Evaldas; Rouman, Mina; Disha, Kushtrim; Espinoza, Andres; Dubslaff, Georg; Fey, Beatrix; Theis, Bernhard; Petersen, Iver; Borger, Michael A; Kuntze, Thomas
2016-02-01
We prospectively examined functional characteristics of the aortic root and transvalvular haemodynamic flow in order to define factors associated with the severity of aortopathy in patients undergoing surgery for bicuspid aortic valve (BAV) stenosis. A total of 103 consecutive patients with BAV stenosis (mean age 61 ± 9 years, 66% male) underwent aortic valve replacement ± concomitant aortic surgery from January 2012 through March 2014. All patients underwent preoperative cardiac magnetic resonance imaging (MRI) in order to evaluate the systolic transvalvular flow and the following functional parameters: (i) angulation between the left ventricular outflow axis and the aortic root, (ii) geometrical orientation of residual aortic valve orifice and (iii) BAV cusp fusion pattern. MRI data were used to guide sampling of the ascending aorta during surgery [i.e. jet-sample from the area where the flow-jet impacts on the aortic wall and control sample from the opposite aortic wall (obtained from the aortotomy site)]. Aortopathy was quantified by means of a histological sum-score (0 to 21+) in each sample. A significant correlation was found between histological sum-score in the jet-sample and the angle between the LV outflow axis and the aortic root (r = 0.6, P = 0.007). Moreover, there was a linear correlation between proximal aortic diameter and the angle between systolic flow-jet and ascending aortic wall (r = 0.5, P = 0.006). Logistic regression identified the angle between the LV outflow axis and the aortic root (OR 1.1, P = 0.04) and the angle between the flow-jet and the aortic wall (OR 1.2, P = 0.001) as independent predictors of an indexed proximal aortic diameter ≥22 mm/m(2). Functional parameters of the aortic root may be used to predict the severity of aortopathy in patients with BAV stenosis, and may be useful in predicting future risk of aortic disease in such patients. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Schofer, Joachim; Nietlispach, Fabian; Bijuklic, Klaudija; Colombo, Antonio; Gatto, Fernando; De Marco, Federico; Mangieri, Antonio; Hansen, Lorenz; Bruschi, Giuseppe; Ruparelia, Neil; Rieß, Friedrich-Christian; Maisano, Franscesco; Latib, Azeem
2015-12-21
This study sought to evaluate the use of the Direct Flow Medical (DFM) transcatheter heart valve (Direct Flow Medical, Santa Rosa, California) for the treatment of noncalcific pure aortic regurgitation (AR). The treatment of noncalcific AR has remained a relative contraindication with transcatheter heart valves due to challenges in anchoring devices in the absence of calcium, concerns of valve embolization, and the high risk of significant residual paravalvular leak. The study population consisted of patients treated for severe noncalcific pure AR with transfemoral implantation of a DFM transcatheter heart valve at 6 European centers. The primary endpoint was the composite endpoint of device success and the secondary endpoint was the composite early safety endpoint (according to the VARC-2 criteria). Eleven high-risk (STS score 8.84 ± 8.9, Logistic EuroSCORE 19.9 ± 7.1) patients (mean age 74.7 ± 12.9 years) were included. Device success was achieved in all patients. In 1 patient, the initial valve prosthesis was retrieved after pull-through, and a second valve was successfully deployed. The early safety endpoint was reached in 91% of the patients, with 1 patient requiring surgical aortic valve replacement secondary to downward dislocation of the prosthesis that was successfully managed with surgical aortic valve replacement. DFM implantation resulted in excellent hemodynamics with none or trivial paravalvular regurgitation in 9 patients and a transprosthetic gradient of 7.7 ± 5.1 mm Hg at 30-day follow up. All patients derived symptomatic benefit following the procedure, with 72% in New York Heart Association functional class I or II. This study reports the feasibility of treating severe noncalcific AR with the Direct Flow prosthesis via the transfemoral route. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Niwa, Koichiro
2017-12-01
Marfan syndrome, bicuspid aortic valve, and/or coarctation of the aorta are associated with medial abnormalities of the ascending aortic or para-coarctation aorta. Medial abnormalities in the ascending aorta are prevalent in other type of patients with a variety of CHDs such as single ventricle, persistent truncus arteriosus, transposition of the great arteries, hypoplastic left heart syndrome, and tetralogy of Fallot, encompassing a wide age range and may predispose to dilatation, aneurysm, and rapture necessitating aortic valve and root surgery. These CHDs exhibit ongoing dilatation of the aortic root and reduced aortic elasticity and increased aortic stiffness that may relate to intrinsic properties of the aortic root. These aortic dilatation and increased stiffness can induce aortic aneurysm, rapture of the aorta, and aortic regurgitation, but also provoke left ventricular hypertrophy, reduced coronary artery flow, and left ventricular failure. Therefore, a new clinical entity can be used to call this association of aortic pathophysiological abnormality, aortic dilation, and aorto-left ventricular interaction - "aortopathy".
Bundle-branch reentry ventricular tachycardia after transcatheter aortic valve replacement
de la Rosa Riestra, Adriana; Rubio Caballero, José Amador; Freites Estévez, Alfonso; Alonso Belló, Javier; Botas Rodríguez, Javier
2016-01-01
An 83-year-old male suffering from severe symptomatic aortic valve stenosis received an implant of a biological aortic prosthesis through the femoral artery without complications. Seven days after dischargement he experienced a syncope. The patient was wearing an ECG holter monitor that day, which showed a wide QRS complex tachycardia of 300 beats per minute. The electrophysiological study revealed a bundle-branch reentry ventricular tachycardia as the cause of the syncope. Radio-frequency was applied on the right-bundle branch. Twelve months later, the patient has remained asymptomatic. PMID:27134443
[Clinical analysis of different root treatment methods in acute Stanford type A aortic dissection].
Xue, Y X; Zhou, Q; Pan, J; Wang, Q; Cao, H L; Fan, F D; Wang, D J
2017-04-01
Objective: To discuss the perioperative and follow-up results of different surgical methods for acute Stanford type A aortic dissection patients and analyzed the results. Methods: The clinic data of 351 acute Stanford type A aortic dissection patients received surgical therapy at Department of Thoracic and Cardiovascular Surgery, Nanjing University Medical School Affiliated Nanjing Drum Tower Hospital from January 2008 to December 2015 were analyzed retrospectively. There were 272 male and 79 female patients, aging from 22 to 83 years with a mean age of (52±13) years. According to root size, aortic valve structure and the status of dissection involvement, these patients were devided into three major groups: 218 cases with root reconstruction using Dacron felts, 34 cases with root reconstruction concomitant with aortic valve resuspension repair and 99 cases in with Bentall procedure. Proper shape based on the status of dissection involvement of Dacron patch was cut and put between the middle and outerlayer of aorta, then inside the inner layerone band Dacron felt was sutured with the aorta and the new middle layer with Dacron patch as mentioned above. In some cases the prolapsed aortic valve was re-suspended to the aortic cusp. Clinical outcomes among the 3 procedures were compared by χ(2) test, Fisher's exact test, t test and analysis of variance. Results: Cardiopulmonary bypass, cross-clamp, and circulatory arrest times of all the patients were (250±78), (171±70) and (31±10) minutes, respectively. The 30-day mortality was 9.2%(33/351), while no difference among the 3 procedures (9.6%, 8.8% and 9.1%). In the average follow-up time of (26.0±23.0) months (range from 0.5 to 90.0 months), survival rates were similar among the 3 procedures (77.7%, 77.4% and 77.8%). Only one patient received redo Bentall procedure because of severe aortic regurgitation and dilated aortic root (diameter of 50 mm). Conclusions: The indication of root management of acute Stanford type A aortic dissection is based on the diameter of aortic root, structure of aortic leaflets, and the dissection involvement. For most acute Stanford type A aortic dissection patients, aortic root reconstruction is a feasible and safe method.
[Phonomechanocardiography in the evaluation of the functional status of valvular prosthesis].
Esquivel Avila, J; Molina Zapata, B; Martínez Ríos, M A; Flamand, E
1975-01-01
The FMCG in 22 patients with valvular prosthesis is analyzed and its clinical, hemodynamic and surgical correlation are established (11 from the I.N.C. and 11 from the Hospital Infantil I.M.A.N.). The average age of the patients was 15 years old, 18 had a mitral and six aortic valvulopathy, and they all required a valvular replacement. Of the mitral prosthesis, 14 were Starr-Edwards (13 of ball valve and one of disc), three Lillehei-Kaster and one Börck-Shiley. In 5 patients, the FMCG suspected disfunction that was later corroborated by catheterism in three patients and by surgery in all of them. The important differences of the FMCG between the group with good and the one with bad function were: the aparition of a rumble, a decrease in the amplitud of the closing snap, index of closing snap opering snap of less than one, lenghtening of fases PFVP and IVCP, and shortening of IVDRP. In the patients with auricular fibrilation, after long dyastoles; that would represent an adequate atrial emptying; the closing snap was more intense, the PFVP was lennthened the IVDRP was shortened when the prosthesis was not properly functioning. All the aortic prosthesis were ball valve Starr-Edwards type; in one the FMCG suspected disfunction and the patient had a sudden death outside of the Hospital. The significant differences of the FMCG were the decrease in the intensity of the opening snap, with a Hylen index of less than one, lengthening of the PFVP, IVCP and of the expulsive period (EP). The authors conclude that the FMCG is a good method for an early detection of the disfunctions of valvular prosthesis.
Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J
2016-01-05
Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement [Medtronic CoreValve U.S. Pivotal Trial]; NCT01240902). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Lacro, Ronald V.; Guey, Lin T.; Dietz, Harry C.; Pearson, Gail D.; Yetman, Anji T.; Gelb, Bruce D.; Loeys, Bart L.; Benson, D. Woodrow; Bradley, Timothy J.; De Backer, Julie; Forbus, Geoffrey A.; Klein, Gloria L.; Lai, Wyman W.; Levine, Jami C.; Lewin, Mark B.; Markham, Larry W.; Paridon, Stephen M.; Pierpont, Mary Ella; Radojewski, Elizabeth; Selamet Tierney, Elif Seda; Sharkey, Angela M.; Wechsler, Stephanie Burns; Mahony, Lynn
2013-01-01
Background The Pediatric Heart Network designed a clinical trial to compare aortic root growth and other short-term cardiovascular outcomes in children and young adults with Marfan syndrome randomized to receive atenolol or losartan. We report here the characteristics of the screened population and enrolled subjects. Methods and results Between 2007 and 2011, 21 clinical sites randomized 608 subjects, aged 6 months to 25 years who met the original Ghent criteria and had a body surface area–adjusted aortic root diameter z-score >3.0. The mean age at study entry was 11.2 years, 60% were male, and 25% were older teenagers and young adults. The median aortic root diameter z-score was 4.0. Aortic root diameter z-score did not vary with age. Mitral valve prolapse and mitral regurgitation were more common in females. Among those with a positive family history, 56% had a family member with aortic surgery, and 32% had a family member with a history of aortic dissection. Conclusions Baseline demographic, clinical, and anthropometric characteristics of the randomized cohort are representative of patients in this population with moderate to severe aortic root dilation. The high percentage of young subjects with relatives who have had aortic dissection or surgery illustrates the need for more definitive therapy; we expect that the results of the study and the wealth of systematic data collected will make an important contribution to the management of individuals with Marfan syndrome. PMID:23622922
Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk
2013-07-01
The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.
Midterm Follow-Up of the Stentless Freedom Solo Bioprosthesis in 350 Patients.
Wollersheim, Laurens W; Li, Wilson W; Bouma, Berto J; Kaya, Abdullah; van Boven, Wim J; van der Meulen, Jan; de Mol, Bas A
2016-07-01
The stentless Freedom Solo aortic bioprosthesis is implanted supraannularly using one running suture line in the sinuses of Valsalva. We report our 9-year experience with this bioprosthesis. From April 2005 to July 2014, 350 consecutive patients at our institution underwent aortic valve replacement with the Freedom Solo bioprosthesis. Follow-up and echocardiographic data were collected retrospectively from referring cardiology centers. The mean age was 76 ± 6 years, 48% were male, and 46% underwent a concomitant procedure. Median EuroSCORE II was 3.0 (interquartile range, 1.9 to 4.9). Operative mortality was 5.1% for all procedures and 2.1% for isolated aortic valve replacement. The 1-, 5-, and 9-year overall survival was 92%, 74%, and 47%, respectively. At 6 years, freedom from structural valve deterioration and freedom from aortic valve reoperation were 98% and 96%, respectively. Prosthetic valve endocarditis occurred at a rate of 0.8% per patient-year. Permanent pacemaker implantation was necessary in 2.3% (n = 8), and moderate and severe prosthesis-patient mismatch occurred in 30 patients overall (9.6%). Postoperative maximum and mean valvular gradients were 17 mm Hg and 10 mm Hg, respectively, and remained stable during follow-up. Aortic valve replacement with the Freedom Solo is safe and has a low rate of permanent pacemaker implantations and prosthesis-patient mismatch. Survival is comparable to that with other aortic bioprostheses, and structural valve deterioration and aortic valve reoperation are infrequent during midterm follow-up. Hemodynamic performance is excellent, with low valvular gradients that remain stable during follow-up. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Gulino, Simona; Barbanti, Marco; Deste, Wanda; Immè, Sebastiano; Aruta, Patrizia; Bottari, Vera; Benvenuto, Emanuele; Tamburino, Claudia; Di Landro, Alessio; Liberto, Daria; Santonoceto, Letizia; Sicuso, Rita; Di Stefano, Daniele; Todaro, Denise; Di Simone, Emanuela; Indelicato, Antonino; Giannazzo, Daniela; Sgroi, Carmelo; Tamburino, Corrado
2016-10-10
Long-term data on the durability of currently available transcatheter heart valves are limited. We sought to assess four-year clinical and echocardiographic outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis. Between June 2007 and February 2014, 450 consecutive patients with symptomatic severe aortic stenosis underwent TAVI in our institution. For the purposes of this study, we included only those patients undergoing successful TAVI with the CoreValve prosthesis who had a minimum follow-up of four years (n=125). Survival rates at one, two, three and four years were 83.2, 76.8, 73.6 and 66.3%, respectively. Aortic regurgitation was a common finding after the procedure, especially due to paravalvular regurgitation (PVR), which was observed in the majority of patients (71.5%), mostly mild (52.0%). Progression from mild acute PVR to moderate PVR at four-year follow-up was reported in three patients. No cases of severe PVR were observed. Prosthetic valve failure was reported in four patients (3.2%). Our study demonstrates that favourable outcomes after successful TAVI are associated with sustained clinical and functional cardiovascular benefits up to four-year follow-up. Signs of moderate prosthetic valve failure are present only in a small percentage of patients.
A New Cone-Shaped Aortic Valve Prosthesis for Orthotopic Position: An Experimental Study in Swine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan, E-mail: jan.sochman@medicon.c; Peregrin, Jan H.; Pulda, Zdenek
The aim of this experimental study was to evaluate a newly designed cone-shaped aortic valve prosthesis (CAVP) for one-step transcatheter placement in an orthotopic position. The study was conducted in 15 swine using either the transcarotid (11 animals) or the transfemoral (4 animals) artery approach. A 12- or 13-Fr sheath was inserted via arterial cutdown. The CAVP was deployed under fluoroscopic control and its struts, by design, induced significant native valve insufficiency. CAVP function was evaluated by aortography and aortic pressure curve tracing. In 11 of 15 swine the CAVP was properly deployed and functioned well throughout the scheduled periodmore » of 2-3 h. In three swine the CAVPs were placed lower than intended, however, they were functional even in the left ventricular outflow tract position. One swine expired due to inadvertent low CAVP placement that caused both aortic regurgitation and immobilization of the anterior mitral valve leaflet by the valve struts. We conclude that this design of CAVP is relatively easy to deploy, works well throughout a short time period (2-3 h), and, moreover, seems to be reliable even in a lower-than-orthotopic position (e.g., infra-annulary space). Longer-term studies are needed for its further evaluation.« less
Aortic root dilatation in athletic population.
Pelliccia, Antonio; Di Paolo, Fernando M; Quattrini, Filippo M
2012-01-01
Remodeling of the aortic root may be expected to occur in athletes as a consequence of hemodynamic overload associated with exercise training; however, there are few data reporting its presence or extent. This review reports the current knowledge regarding the prevalence, upper limits, and clinical significance of aortic remodeling induced by athletic training. Several determinants impact aortic dimension in healthy, nonathletic individuals, including height, body size, age, sex, and blood pressure. Of these factors, anthropometric variables have the greatest impact. In athletes, the effect of exercise training appears to have only a modest additional influence on aortic dimension, although previous studies have produced some conflicting results. Specifically, data derived from the largest available athletic cohort suggest that the most hemodynamically intense endurance disciplines (eg, cycling and swimming) are associated with a significant but mild increase in aortic dimensions. Power disciplines, instead, (eg, weight lifting, throwing events) have only trivial, if any, impact. In contrast, selected data from a different athlete population suggest a more significant dimensional aortic remodeling in strength-trained individuals. In our experience, the 99th percentile value of aortic root diameter corresponds to 40 mm in males and 34 mm in females, which can reasonably be considered the upper limits of physiologic aortic root remodeling. However, a small proportion of apparently healthy male athletes (approximately 1%) show aortic enlargement above the upper limits, in the absence of systemic disease (ie, Marfan syndrome). Athletes presenting with aortic enlargement may demonstrate a further dimensional increase in midlife leading to clinically relevant aortic dilatation. Occasionally, dilation may be severe enough to warrant consideration for surgical treatment. Therefore, serial clinical and echocardiographic evaluations are recommended in athletes when aortic root exceeds the sex-specific thresholds. Copyright © 2012 Elsevier Inc. All rights reserved.
den Hartog, Alexander W.; Radonic, Teodora; de Vries, Carlie J. M.; Zwinderman, Aeilko H.; Groenink, Maarten; Mulder, Barbara J. M.; de Waard, Vivian
2014-01-01
Aims Patients with Marfan syndrome have an increased risk of life-threatening aortic complications, mostly preceded by aortic dilatation. In the FBN1 C1039G/+ Marfan mouse model, losartan decreases aortic root dilatation. We recently confirmed this beneficial effect of losartan in adult patients with Marfan syndrome. The straightforward translation of this mouse model to man is reassuring to test novel treatment strategies. A number of studies have shown signs of inflammation in aortic tissue of Marfan patients. This study examined the efficacy of anti-inflammatory therapies in attenuating aortic root dilation in Marfan syndrome and compared effects to the main preventative agent, losartan. Methods and Results To inhibit inflammation in FBN1 C1039G/+ Marfan mice, we treated the mice with losartan (angiotensin II receptor type 1 inhibitor), methylprednisolone (corticosteroid) or abatacept (T-cell-specific inhibitor). Treatment was initiated in adult Marfan mice with already existing aortic root dilatation, and applied for eight weeks. Methylprednisolone- or abatacept-treated mice did not reveal a reduction in aortic root dilatation. In this short time frame, losartan was the only treatment that significantly reduced aorta inflammation, transforming growth factor-beta (TGF-β) signaling and aortic root dilatation rate in these adult Marfan mice. Moreover, the methylprednisolone-treated mice had significantly more aortic alcian blue staining as a marker for aortic damage. Conclusion Anti-inflammatory agents do not reduce the aortic dilatation rate in Marfan mice, but possibly increase aortic damage. Currently, the most promising therapeutic drug in Marfan syndrome is losartan, by blocking the angiotensin II receptor type 1 and thereby inhibiting pSmad2 signaling. PMID:25238161
Chiu, Hsin-Hui; Wu, Mei-Hwan; Wang, Jou-Kou; Lu, Chun-Wei; Chiu, Shuenn-Nan; Chen, Chun-An; Lin, Ming-Tai; Hu, Fu-Chang
2013-03-01
To assess the tolerability and efficacy of the investigational use of the angiotensin II receptor blocker losartan added to β-blockade (BB) to prevent progressive aortic root dilation in patients with Marfan syndrome (MFS). Between May 1, 2007, and September 31, 2011, 28 patients with MFS (11 males [39%]; mean ± SD age, 13.1±6.3 years) with recognized aortic root dilation (z score >2.0) and receiving BB (atenolol or propranolol) treatment were enrolled. They were randomized to receive BB (BB: 13 patients) or β-blockade and losartan (BB-L: 15 patients) for 35 months. In the BB-L group, aortic root dilation was reduced with treatment, and the annual dilation rate of the aortic root was significantly lower than that of the BB group (0.10 mm/yr vs 0.89 mm/yr; P=.02). The absolute aortic diameters at the sinus of Valsalva, annulus, and sinotubular junction showed similar trends, with a reduced rate of dilation in the BB-L group (P=.02, P=.03, and P=.03, respectively). Five patients (33%) treated with BB-L were noted to have a reduced aortic root diameter. However, the differences between the groups regarding changes in aortic stiffness and cross-sectional compliance were not statistically significant. This randomized, open-label, active controlled trial mostly based on a pediatric population demonstrated for the first time that losartan add-on BB therapy is safe and provides more effective protection to slow the progression of aortic root dilation than does BB treatment alone in patients with MFS. clinicaltrials.gov Identifier: NCT00651235. Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
De Paulis, R; De Matteis, G M; Nardi, P; Scaffa, R; Buratta, M M; Chiariello, L
2001-08-01
The durability of aortic valve-sparing procedures is negatively affected by increased leaflet stress in the absence of normally shaped sinuses of Valsalva. We compared valve motion after remodeling procedures using a standard conduit and a specifically designed aortic root conduit. Echocardiographic studies of the aortic valve dynamics were performed in 14 patients after remodeling of the aortic root (7 standard conduits, group A; 7 new conduits, group B) and in 7 controls (group C). Opening and closing leaflet velocities and percent of slow closing leaflet displacement were measured. Root distensibility and the pressure strain of the elastic modulus were measured at all root levels. Root distensibility and the pressure strain of the elastic modulus were different in group A and B only at the sinuses (p < 0.001). Opening and closing leaflet velocities were not different among groups. Slow closing leaflet displacement was markedly more evident in group B patients (24.2%+/-1.9% versus 2.5%+/-1.9% in group A, p < 0.001) and similar to controls (22.1%+/-7.9%). The new conduit guarantees dynamic features of the aortic valve leaflets superior to those obtained with standard conduits and more similar to normal subjects.
Garlicki, Miroslaw; Roguski, K; Puchniewicz, M; Ehrlich, Marek P
2006-08-01
We report in this study our results with composite aortic root replacement (CVR) using the classic or modified Cabrol coronary implantation technique. From October 2001 to March 2005, 25 patients underwent aortic root replacement. In all cases, the indication for surgery was a degenerative aneurysm with a diameter of more than 6 cm. Seven patients had undergone a previous aortic operation on the ascending aorta. Mean age was 53+/-13 years and 22 patients were male. Mean Euroscore was 5.2+/-2.4. Aortic insufficiency was present in all patients. Two patients had Marfan syndrome. The 30-day mortality was 0%. Two patients required profound hypothermic circulatory arrest. Mean aortic cross-clamp time was 91+/-24 minutes and the mean circulatory arrest time was 24+/-15 minutes. No patients developed a pseudoaneurysm after the operation. We conclude that composite aortic root replacement with the classic or modified Cabrol technique results in a low operative mortality. However, it should be only used when a "button" technique is not feasible.
[Selection of patients for transcatheter aortic valve implantation].
Tron, Christophe; Godin, Matthieu; Litzler, Pierre-Yves; Bauer, Fabrice; Caudron, Jérome; Dacher, Jean-Nicolas; Borz, Bogdan; Canville, Alexandre; Kurtz, Baptiste; Bessou, Jean-Paul; Cribier, Alain; Eltchaninoff, Hélène
2012-06-01
A good selection of patients is a crucial step before transcatheter aortic valve implantation (TAVI) in order to select the good indications and choose the access route. TAVI should be considered only in patients with symptomatic severe aortic stenosis and either contraindication or high surgical risk. Indication for TAVI should be discussed in a multidisciplinary team meeting. Echocardiography and/or CT scan are mandatory to evaluate the aortic annulus size and select the good prosthesis size. The possibility of transfemoral implantation is evaluated by angiography and CT scan, and based on the arterial diameters, but also on the presence of tortuosities and arterial calcifications. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Valve-sparing aortic root replacement in Loeys-Dietz syndrome.
Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A
2011-08-01
Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Valve repair in aortic regurgitation without root dilatation--aortic valve repair.
Lausberg, H F; Aicher, D; Kissinger, A; Langer, F; Fries, R; Schäfers, H-J
2006-02-01
Aortic valve repair was established in the context of aortic root remodeling. Variable results have been reported for isolated valve repair. We analyzed our experience with isolated valve repair and compared the results with those of aortic root remodeling. Between October 1995 and August 2003, isolated repair of the aortic valve was performed in 83 patients (REP), remodeling of the aortic valve in 175 patients (REMO). The demographics of the two groups were comparable (REP: mean age 54.4 +/- 20.7 yrs, male-female ratio 2.1 : 1; REMO: mean age 60.8 +/- 13.6 yrs, male-female ratio 2.4 : 1; p = ns). In both groups the number of bicuspid valves was comparable (REP: 41 %, REMO: 32 %; p = ns). All patients were followed by echocardiography for a cumulative follow-up of 8204 patient months (mean 32 +/- 23 months). Overall in-hospital mortality was 2.4 % in REP and 4.6 % in REMO ( p = 0.62). Systolic gradients were comparable in both groups (REP: 5.8 +/- 2.2, REMO: 6.5 +/- 3.1 mm Hg, p = 0.09). The mean degree of aortic regurgitation 12 months postoperatively was 0.8 +/- 0.7 after REP and 0.7 +/- 0.7 after REMO ( p = 0.29). Freedom from significant regurgitation (> or = II degrees ) after 5 years was 86 % in REP and 89 % in REMO ( p = 0.17). Freedom from re-operation after 5 years was 94.4 % in REP and 98.2 % in REMO ( p = 0.33). Aortic regurgitation without concomitant root dilatation can be treated effectively by aortic valve repair. The functional results are equivalent to those obtained with valve-preserving root replacement. Aortic valve repair appears to be an alternative to valve replacement in aortic regurgitation.
A geometric approach to aortic root surgical anatomy.
Contino, Monica; Mangini, Andrea; Lemma, Massimo Giovanni; Romagnoni, Claudia; Zerbi, Pietro; Gelpi, Guido; Antona, Carlo
2016-01-01
The aim of this study was the analysis of the geometrical relationships between the different structures constituting the aortic root, with particular attention to interleaflet triangles, haemodynamic ventriculo-arterial junction and functional aortic annulus in normal subjects. Sixteen formol-fixed human hearts with normal aortic roots were studied. The aortic root was isolated, sectioned at the midpoint of the non-coronary sinus, spread apart and photographed by a high-resolution digital camera. After calibration and picture resizing, the software AutoCAD 2004 was used to identify and measure all the elements of the interleaflets triangles and of the aortic root that were objects of our analysis. Multiple comparisons were performed with one-way analysis of variance for continuous data and with Kruskal-Wallis analysis for non-continuous data. Linear regression and Pearson's product correlation were used to correlate root element dimensions when appropriate. Student's t-test was used to compare means for unpaired data. Heron's formula was applied to estimate the functional aortic annular diameters. The non coronary-left coronary interleaflets triangles were larger, followed by inter-coronary and right-non-coronary ones. The apical angle is <60° and its standard deviation can be considered an asymmetry index. The sinu-tubular junction was shown to be 10% larger than the virtual basal ring (VBR). The mathematical relationship between the haemodynamic ventriculo-arterial junction and the VBR calculated by linear regression and expressed in terms of the diameter was: haemodynamic ventriculo-arterial junction = 2.29 VBR (diameter) + 47. Conservative aortic surgery is based on a better understanding of aortic root anatomy and physiology. The relationships among its elements are of paramount importance during aortic valve repair/sparing procedures and they can be useful also in echocardiographic analysis and in computed tomography reconstruction. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico
2017-04-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.
Aortic root dynamism, geometry, and function after the remodeling operation: Clinical relevance.
Yacoub, Magdi H; Aguib, Heba; Gamrah, Mazen Abou; Shehata, Nairouz; Nagy, Mohamed; Donia, Mohamed; Aguib, Yasmine; Saad, Hesham; Romeih, Soha; Torii, Ryo; Afifi, Ahmed; Lee, Su-Lin
2018-04-13
Valve-conserving operations for aneurysms of the ascending aorta and root offer many advantages, and their use is steadily increasing. Optimizing the results of these operations depends on providing the best conditions for normal function and durability of the new root. Multimodality imaging including 2-dimensional echocardiography, multislice computed tomography, and cardiovascular magnetic resonance combined with image processing and computational fluid dynamics were used to define geometry, dynamism and aortic root function, before and after the remodeling operation. This was compared with 4 age-matched controls. The size and shape of the ascending aorta, aortic root, and its component parts showed considerable changes postoperatively, with preservation of dynamism. The postoperative size of the aortic annulus was reduced without the use of external bands or foreign material. Importantly, the elliptical shape of the annulus was maintained and changed during the cardiac cycle (Δ ellipticity index was 15% and 28% in patients 1 and 2, respectively). The "cyclic" area of the annulus changed in size (Δarea: 11.3% in patient 1 and 13.1% in patient 2). Functional analysis showed preserved reservoir function of the aortic root, and computational fluid dynamics demonstrated normalized pattern of flow in the ascending aorta, sinuses of Valsalva, and distal aorta. The remodeling operation results in near-normal geometry of the aortic root while maintaining dynamism of the aortic root and its components. This could have very important functional implications; the influence of these effects on both early- and long-term outcomes needs to be studied further. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Sierad, Leslie Neil; Shaw, Eliza Laine; Bina, Alexander; Brazile, Bryn; Rierson, Nicholas; Patnaik, Sourav S.; Kennamer, Allison; Odum, Rebekah; Cotoi, Ovidiu; Terezia, Preda; Branzaniuc, Klara; Smallwood, Harrison; Deac, Radu; Egyed, Imre; Pavai, Zoltan; Szanto, Annamaria; Harceaga, Lucian; Suciu, Horatiu; Raicea, Victor; Olah, Peter; Simionescu, Agneta; Liao, Jun; Movileanu, Ionela
2015-01-01
There is a great need for living valve replacements for patients of all ages. Such constructs could be built by tissue engineering, with perspective of the unique structure and biology of the aortic root. The aortic valve root is composed of several different tissues, and careful structural and functional consideration has to be given to each segment and component. Previous work has shown that immersion techniques are inadequate for whole-root decellularization, with the aortic wall segment being particularly resistant to decellularization. The aim of this study was to develop a differential pressure gradient perfusion system capable of being rigorous enough to decellularize the aortic root wall while gentle enough to preserve the integrity of the cusps. Fresh porcine aortic roots have been subjected to various regimens of perfusion decellularization using detergents and enzymes and results compared to immersion decellularized roots. Success criteria for evaluation of each root segment (cusp, muscle, sinus, wall) for decellularization completeness, tissue integrity, and valve functionality were defined using complementary methods of cell analysis (histology with nuclear and matrix stains and DNA analysis), biomechanics (biaxial and bending tests), and physiologic heart valve bioreactor testing (with advanced image analysis of open–close cycles and geometric orifice area measurement). Fully acellular porcine roots treated with the optimized method exhibited preserved macroscopic structures and microscopic matrix components, which translated into conserved anisotropic mechanical properties, including bending and excellent valve functionality when tested in aortic flow and pressure conditions. This study highlighted the importance of (1) adapting decellularization methods to specific target tissues, (2) combining several methods of cell analysis compared to relying solely on histology, (3) developing relevant valve-specific mechanical tests, and (4) in vitro testing of valve functionality. PMID:26467108
Urbanski, Paul P.; Lenos, Aristidis; Irimie, Vadim; Bougioukakis, Petros; Zacher, Michael; Diegeler, Anno
2016-01-01
OBJECTIVES The aim of the study was to evaluate operative and long-term results after surgery of acute aortic dissection involving the root, in which the proximal repair consisted of curative resection of all dissected aortic sinuses and was performed using either valve-sparing root repair or complete root replacement with a valve conduit. METHODS Between August 2002 and March 2013, 162 consecutive patients (mean age 63 ± 14 years) underwent surgery for acute type A aortic dissection. Eighty-six patients with an involvement of the aortic root underwent curative surgery of the proximal aorta consisting of valve-sparing root repair (n = 54, 62.8%) or complete valve and root replacement using composite valve grafts (n = 32, 37.2%). In patients with root repair, all dissected aortic walls were resected and root remodelling using the single patch technique (n = 53) or root repair with valve reimplantation (n = 1) was performed without the use of any glue. All perioperative data were collected prospectively and retrospective statistical examination was performed using univariate and multivariate analyses. RESULTS The mean follow-up was 5.2 ± 3.5 years for all patients (range 0–12 years) and 6.1 ± 3.3 years for survivors. The 30-day mortality rate was 5.8% (5 patients), being considerably lower in the repair sub-cohort (1.9 vs 12.5%). The estimated survival rate at 5 and 10 years was 80.0 ± 4.5 and 69.1 ± 6.7%, respectively. No patient required reoperation on the proximal aorta and/or aortic valve during the follow-up time and there were only two valve-related events (both embolic, one in each group). Among those patients with repaired valves, the last echocardiography available showed no insufficiency in 40 and an irrelevant insufficiency (1+) in 14. CONCLUSIONS Curative repair of the proximal aorta in acute dissection involving the root provides favourable operative and long-term outcome with very low risk of aortic complications and/or reoperations, regardless if a valve-sparing procedure or replacement with a valve conduit is used. Valve-sparing surgery is frequently suitable, providing excellent outcome and very high durability. PMID:26848190
Correction of aortic insufficiency with an external adjustable prosthetic aortic ring.
Gogbashian, Andrew; Ghanta, Ravi K; Umakanthan, Ramanan; Rangaraj, Aravind T; Laurence, Rita G; Fox, John A; Cohn, Lawrence H; Chen, Frederick Y
2007-09-01
Less invasive, valve-sparing options are needed for patients with aortic insufficiency (AI). We sought to evaluate the feasibility of reducing AI with an external adjustable aortic ring in an ovine model. To create AI, five sheep underwent patch plasty enlargement of the aortic annulus and root by placement of a 10 x 15 mm pericardial patch between the right and noncoronary cusps. An adjustable external ring composed of a nylon band was fabricated and placed around the aortic root. Aortic flow, aortic pressure, and left ventricular pressures were measured with the ring loose (off) and tightened (on). Mean regurgitant orifice area decreased by 86%, from 0.07 +/- 0.03 cm2 (ring loose, off) to 0.01 +/- 0.00 cm2 (ring tightened, on) [p < 0.01]. The regurgitant fraction decreased from 18 +/- 4% to 2 +/- 1% [p < 0.01]. The ring did not significantly affect stroke volume and aortic pressure. An ovine model of aortic root dilatation resulting in acute AI has been developed. In this model, application of an external, adjustable constricting aortic ring eliminated AI. An aortic ring may be a useful adjunct in reducing AI secondary to annular dilatation.
Girdauskas, Evaldas; Rouman, Mina; Disha, Kushtrim; Fey, Beatrix; Dubslaff, Georg; Theis, Bernhard; Petersen, Iver; Gutberlet, Matthias; Borger, Michael A; Kuntze, Thomas
2016-04-19
The correlation between bicuspid aortic valve (BAV) disease and aortopathy is not fully defined. This study aimed to prospectively analyze the correlation between functional parameters of the aortic root and expression of aortopathy in patients undergoing surgery for BAV versus tricuspid aortic valve (TAV) stenosis. From January 1, 2012 through December 31, 2014, 190 consecutive patients (63 ± 8 years, 67% male) underwent aortic valve replacement ± proximal aortic surgery for BAV stenosis (n = 137, BAV group) and TAV stenosis (n = 53, TAV group). All patients underwent pre-operative cardiac magnetic resonance imaging to evaluate morphological/functional parameters of the aortic root. Aortic tissue was sampled during surgery on the basis of the location of eccentric blood flow contact with the aortic wall, as determined by cardiac magnetic resonance (i.e., jet sample and control sample). Aortic wall lesions were graded using a histological sum score (0 to 21). The largest cross-sectional aortic diameters were at the mid-ascending level in both groups and were larger in BAV patients (40.2 ± 7.2 mm vs. 36.6 ± 3.3 mm, respectively, p < 0.001). The histological sum score was 2.9 ± 1.4 in the BAV group versus 3.4 ± 2.6 in the TAV group (p = 0.4). The correlation was linear and comparable between the maximum indexed aortic diameter and the angle between the left ventricular outflow axis and aortic root (left ventricle/aorta angle) in both groups (BAV group: r = 0.6, p < 0.001 vs. TAV group r = 0.45, p = 0.03, z = 1.26, p = 0.2). Logistic regression identified the left ventricle/aorta angle as an indicator of indexed aortic diameter >22 mm/m(2) (odds ratio: 1.2; p < 0.001). Comparable correlation patterns between functional aortic root parameters and expression of aortopathy are found in patients with BAV versus TAV stenosis. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Verhoye, Jean-Philippe; Belhaj Soulami, Reda; Fouquet, Olivier; Ruggieri, Vito Giovanni; Kaladji, Adrien; Tomasi, Jacques; Sellin, Michel; Farhat, Fadi; Anselmi, Amedeo
2017-10-01
Our goal was to evaluate the operative outcomes of the frozen elephant trunk technique using the E-Vita Open Plus® hybrid prosthesis in chronic aortic arch diseases and report clinical and radiological outcomes at the 1-year follow-up. As determined from a prospective multicentre registry, 94 patients underwent frozen elephant trunk procedures using the E-Vita Open Plus hybrid device for the treatment of chronic aortic conditions, including 50% chronic aortic dissections, 40% degenerative aneurysms and 10% miscellaneous indications. Fifty percent of the cases were reoperations. The perioperative mortality rate was 11.7%. Spinal cord ischaemia and stroke rates were 4% and 9.6%, respectively. The mean cardiopulmonary bypass time was 252 ± 97 min, cardiac ischaemia time was 152 ± 53 min and cerebral perfusion time was 82 ± 22 min. Concomitant procedures were observed in 15% of patients. Among the 83 surviving patients, the survival rate after the 1-year follow-up was 98%. Eleven percent of patients underwent endovascular completion, whereas 4% of patients required aortic reintervention at 1 year. The E-Vita Open Plus hybrid device confirms the favourable short- and mid-term outcomes offered by its predecessor in frozen elephant trunk procedures in patients with chronic aortic arch disease. Implantation of the E-Vita Open Plus is associated with good 1-year survival rates, good rates of favourable aortic remodelling in both chronic dissection and degenerative aneurysms and a reproducible technique in a multicentre registry. Continued follow-up is required due to the risk of evolution at the downstream aorta. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Chiam, Paul Toon-Lim; Ewe, See-Hooi; Soon, Jia-Lin; Ho, Kay-Woon; Sin, Yong-Koong; Tan, Swee-Yaw; Lim, Soo-Teik; Koh, Tian-Hai; Chua, Yeow-Leng
2016-07-01
Percutaneous transcatheter aortic valve implantation (TAVI) has become an established therapy for inoperable and high-surgical-risk patients with severe aortic stenosis. Although TAVI in patients with degenerated surgical aortic bioprostheses (i.e. valve-in-valve TAVI) is increasingly reported in Western studies, such data is lacking in Asian patients. We describe the initial experience of valve-in-valve TAVI in Asia. Eight patients who underwent valve-in-valve TAVI due to degenerated aortic bioprostheses were enrolled. The mechanism of bioprosthetic valve failure was stenotic, regurgitation or mixed. All procedures were performed via transfemoral arterial access, using the self-expanding CoreValve prosthesis or balloon-expandable SAPIEN XT prosthesis. The mean age of the patients was 71.6 ± 13.2 years and five were male. Mean duration to surgical bioprosthesis degeneration was 10.2 ± 4.1 years. Valve-in-valve TAVI was successfully performed in all patients. CoreValve and SAPIEN XT prostheses were used in six and two patients, respectively. There were no deaths, strokes or permanent pacemaker requirement at 30 days, with one noncardiac mortality at one year. All patients experienced New York Heart Association functional class improvement. Post-procedure mean pressure gradients were 20 ± 11 mmHg and 22 ± 8 mmHg at 30 days and one year, respectively. Residual aortic regurgitation (AR) of more than mild severity occurred in one patient at 30 days. At one year, only one patient had mild residual AR. In our experience of valve-in-valve TAVI, procedural success was achieved in all patients without adverse events at 30 days. Good clinical and haemodynamic outcomes were sustained at one year. Copyright © Singapore Medical Association.
Aortic valve dysfunction and aortic dilation in adults with coarctation of the aorta.
Clair, Mathieu; Fernandes, Susan M; Khairy, Paul; Graham, Dionne A; Krieger, Eric V; Opotowsky, Alexander R; Singh, Michael N; Colan, Steven D; Meijboom, Erik J; Landzberg, Michael J
2014-01-01
To determine the prevalence of aortic valve dysfunction, aortic dilation, and aortic valve and ascending aortic intervention in adults with coarctation of the aorta (CoA). Aortic valve dysfunction and aortic dilation are rare among children and adolescents with CoA. With longer follow-up, adults may be more likely to have progressive disease. We retrospectively reviewed all adults with CoA, repaired or unrepaired, seen at our center between 2004 and 2010. Two hundred sixteen adults (56.0% male) with CoA were identified. Median age at last evaluation was 28.3 (range 18.0 to 75.3) years. Bicuspid aortic valve (BAV) was present in 65.7%. At last follow-up, 3.2% had moderate or severe aortic stenosis, and 3.7% had moderate or severe aortic regurgitation. Dilation of the aortic root or ascending aorta was present in 28.0% and 41.6% of patients, respectively. Moderate or severe aortic root or ascending aortic dilation (z-score > 4) was present in 8.2% and 13.7%, respectively. Patients with BAV were more likely to have moderate or severe ascending aortic dilation compared with those without BAV (19.5% vs. 0%; P < 0.001). Age was associated with ascending aortic dilation (P = 0.04). At most recent follow-up, 5.6% had undergone aortic valve intervention, and 3.2% had aortic root or ascending aortic replacement. In adults with CoA, significant aortic valve dysfunction and interventions during early adulthood were uncommon. However, aortic dilation was prevalent, especially of the ascending aorta, in patients with BAV. © 2013 Wiley Periodicals, Inc.
Singh, S D; Xu, X Y; Pepper, J R; Treasure, T; Mohiaddin, R H
2015-08-01
Marfan syndrome is an inherited systemic connective tissue disease which may lead to aortic root disease causing dilatation, dissection and rupture of the aorta. The standard treatment is a major operation involving either an artificial valve and aorta or a complex valve repair. More recently, a personalised external aortic root support (PEARS) has been used to strengthen the aorta at an earlier stage of the disease avoiding risk of both rupture and major surgery. The aim of this study was to compare the stress and strain fields of the Marfan aortic root and ascending aorta before and after insertion of PEARS in order to understand its biomechanical implications. Finite element (FE) models were developed using patient-specific aortic geometries reconstructed from pre and post-PEARS magnetic resonance images in three Marfan patients. For the post-PEARS model, two scenarios were investigated-a bilayer model where PEARS and the aortic wall were treated as separate layers, and a single-layer model where PEARS was incorporated into the aortic wall. The wall and PEARS materials were assumed to be isotropic, incompressible and linearly elastic. A static load on the inner wall corresponding to the patients' pulse pressure was applied. Results from our FE models with patient-specific geometries show that peak aortic stresses and displacements before PEARS were located at the sinuses of Valsalva but following PEARS surgery, these peak values were shifted to the aortic arch, particularly at the interface between the supported and unsupported aorta. Further studies are required to assess the statistical significance of these findings and how PEARS compares with the standard treatment. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Von Der Emde J, J; Eberlein, U; Breme J, J
1990-01-01
From August 1971 through November 1972, we implanted 62 Model 2 DeBakey-Surgitool aortic valve prostheses in 62 patients, 4 of whom later had clinically asymptomatic strut fractures. In 1 case, the patient died suddenly, and autopsy revealed detachment of the ball-cage; in each of the other 3 cases, fractures of 2 struts close to the base of the prosthesis were diagnosed fluoroscopically, and the patients underwent successful reoperation. The interval between implantation and reoperation ranged from 11 months to 16 years, 9 months. In 1 patient, retrospective study of chest radiographs revealed that the fracture had been present for 2(1/2) years. Larger valves (>/= A6) were affected significantly more often than smaller ones. We performed metallurgic analysis of 1 prosthesis: results revealed strut wear from fatigue cracking and secondary abrasion. Strut fracture was also promoted by suspension of the cage at right angles to the prosthetic ring and by use of a pyrolytic carbon ball in a titanium cage (i.e., an occluder harder than its holder). Patients with DeBakey-Surgitool aortic valve prostheses should undergo annual radiologic examinations to enable early detection of strut fractures. Prophylactic valve replacement is not indicated.
Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.
Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa
2016-03-01
A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.
Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico
2017-01-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078
Aortic root remodeling: ten-year experience with 274 patients.
Aicher, Diana; Langer, Frank; Lausberg, Henning; Bierbach, Benjamin; Schäfers, Hans-Joachim
2007-10-01
Dilatation of the aortic root with concomitant aortic regurgitation can be treated by valve-preserving surgery. We have consistently chosen root remodeling rather than reimplantation whenever the aortoventricular junction was not dilated. We have analyzed our 11-year experience with root remodeling. Between October 1995 and October 2006, 274 patients (201 male; 73 female, aged 59 +/- 15 years) were treated by root remodeling in the presence of a preserved aortoventricular diameter (<30 mm). Acute aortic dissection was present in 46 patients. The valve anatomy was tricuspid in 193 and bicuspid in 81 patients. Cusp disease was additionally corrected in 173 (63%) patients. Follow-up was complete in 99%. Cumulative follow-up was 1045 patient-years (mean of 4.0 +/- 2.7 years). Hospital mortality was 3.6% (elective 3.1%; emergency 6.5%). One patient had endocarditis 2 months postoperatively and subsequently underwent valve replacement. Freedom from aortic regurgitation of grade II or more was 91% and 87% at 10 years for bicuspid and tricuspid aortic valves. Nine patients required reoperation: in 6 patients the valve was replaced and in 3 patients rerepaired. Freedom from reoperation was 96% at 5 and 10 years, and freedom from valve replacement was 98% at 5 and 10 years. A comparison of 3 operative periods (1995-1998, 1999-2002, and 2003-2006) showed that with increasing experience cusp prolapse was diagnosed and corrected more frequently (8/49 = 17%; 62/105 = 59%; 103/108 = 82%; P < .0001), and repair stability significantly improved over time (P = .007). Root remodeling leads to durable restoration of aortic valve function in both tricuspid and bicuspid valve anatomy. Aggressive correction of cusp prolapse seems to have a beneficial effect on aortic valve competence.
Pascual, Isaac; Avanzas, Pablo; Muñoz-García, Antonio J; López-Otero, Diego; Jimenez-Navarro, Manuel F; Cid-Alvarez, Belén; del Valle, Raquel; Alonso-Briales, Juan H; Ocaranza-Sanchez, Raimundo; Alfonso, Fernando; Hernández, José M; Trillo-Nouche, Ramiro; Morís, César
2013-10-01
There is little information on the use of transcatheter aortic valve implantation in patients with severe aortic stenosis and porcelain aorta. The primary aim of this study was to analyze death from any cause after CoreValve(®) implantation in patients with severe aortic stenosis, with and without porcelain aorta. In this multicenter, observational prospective study, carried out in 3 hospitals, percutaneous aortic valves were implanted in 449 patients with severely calcified aortic stenosis. Of these, 36 (8%) met the criteria for porcelain aorta. The primary end-point was death from any cause at 2 years. Patients with porcelain aorta more frequently had extracardiac vascular disease (11 [30.6%] vs 49 [11.9%]; P=.002), prior coronary revascularization (15 [41.7%] vs 98 [23.7%]; P=.017), and dyslipidemia (26 [72.2%] vs 186 [45%]; P=.02). In these patients, there was greater use of general anesthesia (15 [41.7%] vs 111 [16.9%]; P=.058) and axillary access (9 [25%] vs 34 [8.2%]; P=.004). The success rate of the procedure (94.4 vs 97.3%; P=.28) and the incidence of complications (7 [19.4%] vs 48 [11.6%]; P=.20) were similar in both groups. There were no statistically significant differences in the primary end point at 24 months of follow-up (8 [22.2%] vs 66 [16%]; P=.33). The only predictive variable for the primary end point was the presence of complications during implantation (hazard ratio=2.6; 95% confidence interval, 1.5-4.5; P=.001). In patients with aortic stenosis and porcelain aorta unsuitable for surgery, percutaneous implantation of the CoreValve(®) self-expanding valve prosthesis is safe and feasible. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.
Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M
2000-11-01
Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.
Teramoto, Chikao; Kawaguchi, Osamu; Araki, Yoshimori; Yoshikawa, Masaharu; Uchida, Wataru; Takemura, Gennta; Makino, Naoki
2016-08-01
In patients with Marfan syndrome, cardiovascular complication due to aortic dissection represents the primary cause of death. Iatrogenic acute aortic dissection during cardiac surgery is a rare, but serious adverse event. A 51-year-old woman with Marfan syndrome underwent elective aortic surgery and mitral valve reconstruction surgery for the enlarged aortic root and severe mitral regurgitation. We replaced the aortic root and ascending aorta based on reimplantation technique. During subsequent mitral valve reconstruction, we found the heart pushed up from behind. Trans-esophageal echocardiography revealed a dissecting flap in the thoracic descending aorta. There was just weak signal of blood flow in the pseudolumen. We did not add any additional procedures such as an arch replacement. Cardio-pulmonary bypass was successfully discontinued. After protamine sulfate administration and blood transfusion, blood flow in the pseudolumen disappeared. The patient was successfully discharged from the hospital on 33th postoperative day without significant morbidities.
Devereux, Richard B; de Simone, Giovanni; Arnett, Donna K; Best, Lyle G; Boerwinkle, Eric; Howard, Barbara V; Kitzman, Dalane; Lee, Elisa T; Mosley, Thomas H; Weder, Alan; Roman, Mary J
2012-10-15
Nomograms to predict normal aortic root diameter for body surface area (BSA) in broad ranges of age have been widely used but are limited by lack of consideration of gender effects, jumps in upper limits of aortic diameter among age strata, and data from older teenagers. Sinus of Valsalva diameter was measured by American Society of Echocardiography convention in normal-weight, nonhypertensive, nondiabetic subjects ≥15 years old without aortic valve disease from clinical or population-based samples. Analyses of covariance and linear regression with assessment of residuals identified determinants and developed predictive models for normal aortic root diameter. In 1,207 apparently normal subjects ≥15 years old (54% women), aortic root diameter was 2.1 to 4.3 cm. Aortic root diameter was strongly related to BSA and height (r = 0.48 for the 2 comparisons), age (r = 0.36), and male gender (+2.7 mm adjusted for BSA and age, p <0.001 for all comparisons). Multivariable equations using age, gender, and BSA or height predicted aortic diameter strongly (R = 0.674 for the 2 comparisons, p <0.001) with minimal relation of residuals to age or body size: for BSA 2.423 + (age [years] × 0.009) + (BSA [square meters] × 0.461) - (gender [1 = man, 2 = woman] × 0.267), SEE 0.261 cm; for height 1.519 + (age [years] × 0.010) + (height [centimeters] × 0.010) - (gender [1 = man, 2 = woman] × 0.247), SEE 0.215 cm. In conclusion, aortic root diameter is larger in men and increases with body size and age. Regression models incorporating body size, age, and gender are applicable to adolescents and adults without limitations of previous nomograms. Copyright © 2012 Elsevier Inc. All rights reserved.
Vorselaars, V M M; Diederik, A; Prabhudesai, V; Velthuis, S; Vos, J-A; Snijder, R J; Westermann, C J J; Mulder, B J; Ploos van Amstel, J K; Mager, J J; Faughnan, M E; Post, M C
2017-10-15
Mutations in the genes ENG, ACVRL1 and SMAD4 that are part of the transforming growth factor-beta signalling pathway cause hereditary haemorrhagic telangiectasia (HHT). Mutations in non-HHT genes within this same pathway have been found to associate with aortic dilation. Therefore, we investigated the presence of aortic dilation in a large cohort of HHT patients as compared to non-HHT controls. Chest computed tomography of consecutive HHT patients (ENG, ACVRL1 and SMAD4 mutation carriers) and non-HHT controls were reviewed. Aortic root dilation was defined as a z-score>1.96. Ascending and descending aorta dimensions were corrected for age, gender and body surface area. In total 178 subjects (57.3% female, mean age 43.9±14.9years) were included (32 SMAD4, 47 ENG, 50 ACVRL1 mutation carriers and 49 non-HHT controls). Aortopathy was present in a total of 42 subjects (24% of total). Aortic root dilatation was found in 31% of SMAD4, 2% of ENG, 6% of ACVRL1 mutation carriers, and 4% in non-HHT controls (p<0.001). The aortic root diameter was 36.3±5.2mm in SMAD4 versus 32.7±3.9mm in the non-SMAD4 group (p=0.001). SMAD4 was an independent predictor for increased aortic root (β-coefficient 3.5, p<0.001) and ascending aorta diameter (β-coefficient 1.6, p=0.04). SMAD4 gene mutation in HHT patients is independently associated with a higher risk of aortic root and ascending aortic dilation as compared to other HHT patients and non-HHT controls. Copyright © 2017 Elsevier B.V. All rights reserved.
Pravastatin reduces Marfan aortic dilation.
McLoughlin, Darren; McGuinness, Jonathan; Byrne, John; Terzo, Eloisa; Huuskonen, Vilhelmiina; McAllister, Hester; Black, Alexander; Kearney, Sinead; Kay, Elaine; Hill, Arnold D K; Dietz, Harry C; Redmond, J Mark
2011-09-13
The sequelae of aortic root dilation are the lethal consequences of Marfan syndrome. The root dilation is attributable to an imbalance between deposition of matrix elements and metalloproteinases in the aortic medial layer as a result of excessive transforming growth factor-beta signaling. This study examined the efficacy and mechanism of statins in attenuating aortic root dilation in Marfan syndrome and compared effects to the other main proposed preventative agent, losartan. Marfan mice heterozygous for a mutant allele encoding a cysteine substitution in fibrillin-1 (C1039G) were treated daily from 6 weeks old with pravastatin 0.5 g/L or losartan 0.6 g/L. The end points of aortic root diameter (n=25), aortic thickness, and architecture (n=10), elastin volume (n=5), dp/dtmax (maximal rate of change of pressure) (cardiac catheter; n=20), and ultrastructural analysis with stereology (electron microscopy; n=5) were examined. The aortic root diameters of untreated Marfan mice were significantly increased in comparison to normal mice (0.161 ± 0.001 cm vs 0.252 ± 0.004 cm; P<0.01). Pravastatin (0.22 ± 0.003 cm; P<0.01) and losartan (0.221 ± 0.004 cm; P<0.01) produced a significant reduction in aortic root dilation. Both drugs also preserved elastin volume within the medial layer (pravastatin 0.23 ± 0.02 and losartan 0.29 ± 0.03 vs untreated Marfan 0.19 ± 0.02; P=0.01; normal mice 0.27 ± 0.02). Ultrastructural analysis showed a reduction of rough endoplasmic reticulum in smooth muscle cells with pravastatin (0.022 ± 0.004) and losartan (0.013 ± 0.001) compared to untreated Marfan mice (0.035 ± 0.004; P<0.01). Statins are similar to losartan in attenuating aortic root dilation in a mouse model of Marfan syndrome. They appear to act through reducing the excessive protein manufacture by vascular smooth muscle cells, which occurs in the Marfan aorta. As a drug that is relatively well-tolerated for long-term use, it may be useful clinically.
Natural history and outcome of aortic stenosis diagnosed prenatally.
Simpson, J. M.; Sharland, G. K.
1997-01-01
OBJECTIVE: To document the growth of the left heart structures and outcome of fetuses with aortic stenosis. DESIGN: Retrospective echocardiographic and clinical study. SETTING: Tertiary centre for fetal cardiology. PATIENTS: 27 consecutive fetuses with aortic stenosis. MAIN OUTCOME MEASURES: Survival of affected fetuses. Measurement of left ventricular end diastolic volume (LVEDV), aortic root diameter, and ejection fraction. RESULTS: Before 25 weeks' gestation, the LVEDV was normal or increased in all cases. In six of eight fetuses studied sequentially, the LVEDV fell across normal centiles. Initial ejection fraction was reduced in 23 fetuses (88%). Before 28 weeks' gestation, the aortic root was normal in all but one case, but after 29 weeks, 11 of 13 fetuses had values below the 50th centile. In two fetuses prenatal aortic valvoplasty was attempted, 10 babies had postnatal interventions, and there were six survivors. Biventricular repair was attempted in eight cases, of whom five survived. A first stage Norwood operation was performed in three babies, of whom one survived. The four fetuses with the highest aortic root z scores had successful biventricular repair. The two fetuses with initially normal ejection fractions survived. Successful biventricular repair was achieved even where the LVEDV was below the 5th centile. CONCLUSIONS: In aortic stenosis diagnosed prenatally, failure of growth of the left ventricle and aortic root often occurs. The outcome of affected fetuses is better than previously reported. Prenatal echocardiography may assist selection of suitable candidates for biventricular versus Norwood repair. Images PMID:9093035
[Modern aortic surgery in Marfan syndrome--2011].
Kallenbach, K; Schwill, S; Karck, M
2011-09-01
Marfan syndrome is a hereditary disease with a prevalence of 2-3 in 10,000 births, leading to a fibrillin connective tissue disorder with manifestations in the skeleton, eye, skin, dura mater and in particular the cardiovascular system. Since other syndromes demonstrate similar vascular manifestations, but therapy may differ significantly, diagnosis should be established using the revised Ghent nosology in combination with genotypic analysis in specialized Marfan centres. The formation of aortic root aneurysms with the subsequent risk of acute aortic dissection type A (AADA) or aortic rupture limits life expectancy in patients with Marfan syndrome. Therefore, prophylactic replacement of the aortic root needs to be performed before the catastrophic event of AADA can occur. The goal of surgery is the complete resection of pathological aortic tissue. This can be achieved with excellent results by using a (mechanically) valved conduit that replaces both the aortic valve and the aortic root (Bentall operation). However, the need for lifelong anticoagulation with Coumadin can be avoided using the aortic valve sparing reimplantation technique according to David. The long-term durability of the reconstructed valve is favourable, and further technical improvements may improve longevity. Although results of prospective randomised long-term studies comparing surgical techniques are lacking, the David operation has become the surgical method of choice for aortic root aneurysms, not only at the Heidelberg Marfan Centre. Replacement of the aneurysmal dilated aortic arch is performed under moderate hypothermic circulatory arrest combined with antegrade cerebral perfusion using a heart-lung machine, which we also use in thoracic or thoracoabdominal aneurysms. Close post-operative follow-up in a Marfan centre is pivotal for the early detection of pathological changes on the diseased aorta.
Resveratrol Inhibits Aortic Root Dilatation in the Fbn1C1039G/+ Marfan Mouse Model.
Hibender, Stijntje; Franken, Romy; van Roomen, Cindy; Ter Braake, Anique; van der Made, Ingeborg; Schermer, Edith E; Gunst, Quinn; van den Hoff, Maurice J; Lutgens, Esther; Pinto, Yigal M; Groenink, Maarten; Zwinderman, Aeilko H; Mulder, Barbara J M; de Vries, Carlie J M; de Waard, Vivian
2016-08-01
Marfan syndrome (MFS) is a connective tissue disorder caused by mutations in the fibrillin-1 gene. Patients with MFS are at risk of aortic aneurysm formation and dissection. Usually, blood pressure-lowering drugs are used to reduce aortic events; however, this is not sufficient for most patients. In the aorta of smooth muscle cell-specific sirtuin-1-deficient mice, spontaneous aneurysm formation and senescence are observed. Resveratrol is known to enhance sirtuin-1 activity and to reduce senescence, which prompted us to investigate the effectiveness of resveratrol in inhibition of aortic dilatation in the Fbn1(C1039G/+) MFS mouse model. Aortic senescence strongly correlates with aortic root dilatation rate in MFS mice. However, although resveratrol inhibits aortic dilatation, it only shows a trend toward reduced aortic senescence. Resveratrol enhances nuclear localization of sirtuin-1 in the vessel wall and, in contrast to losartan, does not affect leukocyte infiltration nor activation of SMAD2 and extracellular signal-regulated kinases 1/2 (ERK1/2). Interestingly, specific sirtuin-1 activation (SRT1720) or inhibition (sirtinol) in MFS mice does not affect aortic root dilatation rate, although senescence is changed. Resveratrol reduces aortic elastin breaks and decreases micro-RNA-29b expression coinciding with enhanced antiapoptotic Bcl-2 expression and decreased number of terminal apoptotic cells. In cultured smooth muscle cells, the resveratrol effect on micro-RNA-29b downregulation is endothelial cell and nuclear factor κB-dependent. Resveratrol inhibits aortic root dilatation in MFS mice by promoting elastin integrity and smooth muscle cell survival, involving downregulation of the aneurysm-related micro-RNA-29b in the aorta. On the basis of these data, resveratrol holds promise as a novel intervention strategy for patients with MFS. © 2016 The Authors.
Resveratrol Inhibits Aortic Root Dilatation in the Fbn1C1039G/+ Marfan Mouse Model
Hibender, Stijntje; Franken, Romy; van Roomen, Cindy; ter Braake, Anique; van der Made, Ingeborg; Schermer, Edith E.; Gunst, Quinn; van den Hoff, Maurice J.; Lutgens, Esther; Pinto, Yigal M.; Groenink, Maarten; Zwinderman, Aeilko H.; Mulder, Barbara J.M.; de Vries, Carlie J.M.
2016-01-01
Objective— Marfan syndrome (MFS) is a connective tissue disorder caused by mutations in the fibrillin-1 gene. Patients with MFS are at risk of aortic aneurysm formation and dissection. Usually, blood pressure–lowering drugs are used to reduce aortic events; however, this is not sufficient for most patients. In the aorta of smooth muscle cell–specific sirtuin-1–deficient mice, spontaneous aneurysm formation and senescence are observed. Resveratrol is known to enhance sirtuin-1 activity and to reduce senescence, which prompted us to investigate the effectiveness of resveratrol in inhibition of aortic dilatation in the Fbn1C1039G/+ MFS mouse model. Approach and Results— Aortic senescence strongly correlates with aortic root dilatation rate in MFS mice. However, although resveratrol inhibits aortic dilatation, it only shows a trend toward reduced aortic senescence. Resveratrol enhances nuclear localization of sirtuin-1 in the vessel wall and, in contrast to losartan, does not affect leukocyte infiltration nor activation of SMAD2 and extracellular signal–regulated kinases 1/2 (ERK1/2). Interestingly, specific sirtuin-1 activation (SRT1720) or inhibition (sirtinol) in MFS mice does not affect aortic root dilatation rate, although senescence is changed. Resveratrol reduces aortic elastin breaks and decreases micro-RNA-29b expression coinciding with enhanced antiapoptotic Bcl-2 expression and decreased number of terminal apoptotic cells. In cultured smooth muscle cells, the resveratrol effect on micro-RNA-29b downregulation is endothelial cell and nuclear factor κB-dependent. Conclusions— Resveratrol inhibits aortic root dilatation in MFS mice by promoting elastin integrity and smooth muscle cell survival, involving downregulation of the aneurysm-related micro-RNA-29b in the aorta. On the basis of these data, resveratrol holds promise as a novel intervention strategy for patients with MFS. PMID:27283746
Sabatino, Jolanda; Mongiardo, Annalisa; Ricci, Pietrantonio; Spaccarotella, Carmen
2017-01-01
Background Aortic stenosis (AS) is the most common heart valve disease in developed countries. The advent of transcatheter aortic valve implantation (TAVI) significantly improved patients' outcome but made clinical management more complex. The aim of the present study was to describe TAVIApp, a mobile app we developed to guide the management of AS, and test its efficacy. Methods and Results Clinical cases comprising 42 patients with AS were blindly evaluated by (A) an interventional cardiologist, assisted by the Heart Team (EXPERT), (B) young residents in cardiology, and (C) a young resident supported by TAVIApp. There was poor concordance between Group A and Group B with low performance by young residents (k = 0.52; p < 0.001). However, concordance increased to an optimal value when young residents were supported by TAVIApp (k = 1.0; p < 0.001) for the diagnosis of severe AS and eligibility assessment. Furthermore, regarding the selection of the most appropriate prosthesis size, concordance to Group A was poor without TAVIApp support (Group B) (k = 0.78; p = 0.430), but excellent with TAVIApp (k = 1.0; p < 0.001). Conclusions This study is the first describing and validating a new mobile application to support the management of AS. TAVIApp supports cardiologists in the evaluation of stenosis severity, eligibility for TAVI or AVR, and selection of the most appropriate prosthesis size in individual patients. PMID:29270437
Montalescot, G; Thomas, D; Drobinski, G; Evans, J I; Vicaut, E; Chatellier, G; Whyte, R I; Busquet, P; Bejean-Lebuisson, A; Grosgogeat, Y
1989-07-01
Mortality, morbidity, quality of life, and left ventricular (LV) function were evaluated in 49 patients after aortic valve replacement with the St. Jude prosthesis. Total follow-up was 2577 patient-months; survivors were followed-up for 4 to 7 years by clinical examination and echocardiography. The actuarial survival rate at 6 years was 79.6%, and there were no valve-related deaths. The linearized rates for thromboembolism and hemorrhage were 0.93% and 3.26% per patient-year, respectively. In 34% of the survivors the quality of life was poor. In the first three postoperative months, patients with aortic stenosis (n = 12) had a significant decrease in the muscle cross-sectional area (p less than 0.01) and patients with aortic regurgitation (n = 11) had decreases in both LV end-diastolic diameter (p less than 0.05) and cross-sectional area (p less than 0.001). All of these results were maintained at 5 years without modification of LV systolic function. Despite the good overall results, six patients deteriorated and had major LV dilatation. Multivariate logistic regression analysis identified two independent preoperative variables associated with a poor outcome defined as death of LV dysfunction (p less than 0.05): age and end-diastolic diameter. Thus meticulous follow-up showed a high incidence of hemorrhage and a poor quality of life in many of the survivors. It was concluded that in high-risk patients (age and end-diastolic diameter) surgery should probably be considered earlier.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav
Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less
Apical Aortic Conduit Infection 27 Years After Repaired Left Ventricular Outflow Tract Obstruction.
Carpenter, Dustin J; Fiore, Andrew C; Huddleston, Charles B
2014-07-01
Left ventricle to aortic conduits were used for the treatment of complex left ventricular outflow tract obstruction in the pediatric population in the mid-1970s. Although this technique has been largely replaced by the Ross-Konno procedure, many patients still have functioning apicoaortic conduits in place today. Few clinical reports or case series exist in pediatric cohorts documenting the natural history or potential long-term complications of this prosthesis. In this report, we describe our experience managing a patient with Shone's syndrome and an apical aortic porcine-valved conduit remnant that became infected 17 years postconduit valve excision for valvular insufficiency. © The Author(s) 2014.
Transforming Growth Factor Beta-2 Mutations in Barlow's Disease and Aortic Dilatation.
Disha, Kushtrim; Schulz, Solveig; Kuntze, Thomas; Girdauskas, Evaldas
2017-07-01
We report on a patient operated on for degenerative myxomatous mitral and tricuspid valve disease (Barlow's disease) and aortic root dilatation. A valve repair operation and the postoperative course were uneventful. Multigenerational genetic analyses revealed two different mutations in the transforming growth factor beta-2 gene in the same patient. The two mutations in different exons were inherited from both parents each. None of the parents presented with either valve dysfunction or aortic root dilatation. This rare case illustrates potentially common genetic and signaling pathways of concomitant myxomatous valve disease and aortic root dilatation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Walther, Thomas; Hamm, Christian W; Schuler, Gerhard; Berkowitsch, Alexander; Kötting, Joachim; Mangner, Norman; Mudra, Harald; Beckmann, Andreas; Cremer, Jochen; Welz, Armin; Lange, Rüdiger; Kuck, Karl-Heinz; Mohr, Friedrich W; Möllmann, Helge
2015-05-26
Transcatheter aortic valve replacement (TAVR) has evolved into a routine procedure with good outcomes in high-risk patients. TAVR complication rates were evaluated based on prospective data from the German Aortic Valve Registry (GARY). From 2011 to 2013, a total of 15,964 TAVR procedures were registered. We evaluated the total cohort for severe vital complications (SVCs), including the following: death on the day of intervention, conversion to sternotomy, low cardiac output that required mechanical support, aortic dissection, and annular rupture; technical complications of the procedures (TCOs), such as repositioning or retrieval of the valve prosthesis and embolization of the prosthesis; and other complications. Mean patient age was 81 ± 6 years, 54% of the patients were women, the median logistic Euroscore I was 18.3, the German aortic valve score was 5.6, and the Society of Thoracic Surgeons score was 5.0. Overall in-hospital mortality was 5.2%, whereas SVCs occurred in 5.0% of the population. Independent predictors for SVCs were female sex, pre-operative New York Heart Association functional class IV, ejection fraction <30%, pre-operative intravenous inotropes, arterial vascular disease, and higher degree of calcifications. TCOs occurred in 4.7% of patients and decreased significantly from 2011 to 2013. An emergency sternotomy was performed in 1.3% of the patients; however, multivariate analysis did not identify any predictors for conversion to sternotomy. The all-comers GARY registry revealed good outcomes after TAVR and a regression in complications. Survival of approximately 60% of patients who experienced SVCs or who required sternotomy underlines the need for heart team-led indication, intervention, and follow-up care of TAVR patients. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Marfan syndrome associated aortic disease in neonates and children: a clinical-morphologic review.
Ware, Adam L; Miller, Dylan V; Erickson, Lance K; Menon, Shaji C
2016-01-01
Marfan syndrome (MFS) is a multisystem connective tissue disorder that can lead to aortic dilation requiring aortic root replacement. Neonatal MFS (nMFS) is a rare and severe form of MFS compared to classic MFS (cMFS). Aortic root histology in MFS is thought to demonstrate predominantly medial degeneration (MD) of a translamellar mucoid extracellular matrix accumulation (MEMA-T) vs. the intralamellar mucoid extracellular matrix accumulation (MEMA-I) seen in other aortopathies. The objective of this study was to describe the clinical and histopathologic features of nMFS and cMFS patients undergoing aortic root replacement. Children with MFS who underwent aortic root replacement between 2000 and 2012 at a single institution were included. Medical records including clinical details, aortic dimensions (Z scores), and histology including MD type were obtained. Statistics were descriptive with univariate analysis of age at surgery and type of MD. Eleven patients, 3 (27%) with nMFS, were included. Root dilation at time of surgery was greater in nMFS compared to cMFS (Z=12.8 vs. 7.6, P=.005), and nMFS patients were younger at time of surgery (7.3 vs. 18.8 years, P=.002). Histology in the nMFS group demonstrated MEMA-I in one and no MD in two. In the cMFS group, there were three with MEMA-T, four with MEMA-I, and one with both types. In summary, nMFS has earlier root dilation often in the absence of MD. Both forms of MD were present in our cohort, and there was no correlation between age at surgery and type of MD. Copyright © 2016 Elsevier Inc. All rights reserved.
[Aortic root dilatation rate in pediatric patients with Marfan syndrome treated with losartan].
Mariucci, Elisabetta; Guidarini, Marta; Donti, Andrea; Lovato, Luigi; Wischmeijer, Anita; Angeli, Emanuela; Gargiulo, Gaetano D; Picchio, Fernando M; Bonvicini, Marco
2015-12-01
Medical therapy with angiotensin II receptor blockers/angiotensin-converting enzyme inhibitors and/or beta-blockers was reported to reduce aortic root dilatation rates in pediatric patients with Marfan syndrome. No data are available in the literature on losartan effects after 3 years of therapy. The aim of our study was to establish whether losartan reduces aortic root dilatation rates in pediatric patients with Marfan syndrome in the mid and long term. This is a retrospective analysis of 38 pediatric patients with Marfan syndrome followed at the Marfan Clinic of S. Orsola-Malpighi Hospital of the University of Bologna (Italy). Aortic diameters were measured at sinuses of Valsalva and proximal ascending aorta with transthoracic echocardiography. After a mean follow-up of 4.5 ± 2.5 years (range 2-9 years), aortic root z score at sinuses of Valsalva and proximal ascending aorta remained stable. The average annual rate of change in aortic root z score was -0.1 ± 0.4 and 0 ± 0.3 at sinuses of Valsalva and proximal ascending aorta, respectively. The mean dose of losartan was 0.7 ± 0.3 mg/kg/day. Three patients were non-responders, probably because of late beginning or low dose of therapy. Eight patients underwent cardiac surgery (aortic root surgery in 5 and mitral valve repair in 3), all of them started losartan later in life. Despite the retrospective design of the study and the small sample size, a beneficial effect of losartan therapy was observed in pediatric patients with Marfan syndrome in the mid and long term. Late beginning or low doses of losartan can turn off the effects of therapy.
Price, Joel; Magruder, J Trent; Young, Allen; Grimm, Joshua C; Patel, Nishant D; Alejo, Diane; Dietz, Harry C; Vricella, Luca A; Cameron, Duke E
2016-02-01
Prophylactic aortic root replacement improves survival in patients with Marfan syndrome with aortic root aneurysms, but the optimal procedure remains undefined. Adult patients with Marfan syndrome who had Bentall or aortic valve-sparing root replacement (VSRR) procedures between 1997 and 2013 were identified. Comprehensive follow-up information was obtained from hospital charts and telephone contact. One hundred sixty-five adult patients with Marfan syndrome (aged > 20 years) had either VSRR (n = 98; 69 reimplantation, 29 remodeling) or Bentall (n = 67) procedures. Patients undergoing Bentall procedure were older (median, 37 vs 36 years; P = .03), had larger median preoperative sinus diameter (5.5 cm vs 5.0 cm; P = .003), more aortic dissections (25.4% vs 4.1%; P < .001), higher incidence of moderate or severe aortic insufficiency (49.3% vs 14.4%; P < .001) and more urgent or emergent operations (24.6% vs 3.3%; P < .001). There were no hospital deaths and 9 late deaths in more than 17 years of follow-up (median, 7.8 deaths). Ten-year survival was 90.5% in patients undergoing Bentall procedure and 96.3% in patients undergoing VSRR (P = .10). Multivariable analysis revealed that VSRR was associated with fewer thromboembolic or hemorrhagic events (hazard ratio, 0.16; 95% confidence interval, 0.03-0.85; P = .03). There was no independent difference in long-term survival, freedom from reoperation, or freedom from endocarditis between the 2 procedures. After prophylactic root replacement in patients with Marfan syndrome, patients undergoing Bentall and valve-sparing procedures have similar late survival, freedom from root reoperation, and freedom from endocarditis. However, valve-sparing procedures result in significantly fewer thromboembolic and hemorrhagic events. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Coselli, Joseph S; Volguina, Irina V; LeMaire, Scott A; Sundt, Thoralf M; Connolly, Heidi M; Stephens, Elizabeth H; Schaff, Hartzell V; Milewicz, Dianna M; Vricella, Luca A; Dietz, Harry C; Minard, Charles G; Miller, D Craig
2014-06-01
To compare the 1-year results after aortic valve-sparing (AVS) or valve-replacing (AVR) aortic root replacement from a prospective, international registry of 316 patients with Marfan syndrome (MFS). Patients underwent AVS (n = 239, 76%) or AVR (n = 77, 24%) aortic root replacement at 19 participating centers from 2005 to 2010. One-year follow-up data were complete for 312 patients (99%), with imaging findings available for 293 (94%). The time-to-events were compared between groups using Kaplan-Meier curves and Cox proportional hazards models. Two patients (0.6%)--1 in each group--died within 30 days. No significant differences were found in early major adverse valve-related events (MAVRE; P = .6). Two AVS patients required early reoperation for coronary artery complications. The 1-year survival rates were similar in the AVR (97%) and AVS (98%) groups; the procedure type was not significantly associated with any valve-related events. At 1 year and beyond, aortic regurgitation of at least moderate severity (≥2+) was present in 16 patients in the AVS group (7%) but in no patients in the AVR group (P = .02). One AVS patient required late AVR. AVS aortic root replacement was not associated with greater 30-day mortality or morbidity rates than AVR root replacement. At 1 year, no differences were found in survival, valve-related morbidity, or MAVRE between the AVS and AVR groups. Of concern, 7% of AVS patients developed grade ≥2+ aortic regurgitation, emphasizing the importance of 5 to 10 years of follow-up to learn the long-term durability of AVS versus AVR root replacement in patients with MFS. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Hellmeier, Florian; Nordmeyer, Sarah; Yevtushenko, Pavlo; Bruening, Jan; Berger, Felix; Kuehne, Titus; Goubergrits, Leonid; Kelm, Marcus
2018-01-01
Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets with and without velocity encoding were obtained to reconstruct the aorta and set hemodynamic boundary conditions for simulations. Aortic hemodynamics after virtual valve replacement with a biological and mechanical valve prosthesis were investigated. Wall shear stress (WSS), secondary flow degree (SFD), transvalvular pressure drop (TPD), turbulent kinetic energy (TKE), and normalized flow displacement (NFD) were evaluated to characterize valve-induced hemodynamics. The biological prostheses induced significantly higher WSS (medians: 9.3 vs. 8.6 Pa, P = 0.027) and SFD (means: 0.78 vs. 0.49, P = 0.002) in the ascending aorta, TPD (medians: 11.4 vs. 2.7 mm Hg, P = 0.002), TKE (means: 400 vs. 283 cm 2 /s 2 , P = 0.037), and NFD (means: 0.0994 vs. 0.0607, P = 0.020) than the mechanical prostheses. The differences between the prosthesis types showed great inter-patient variability, however. Given this variability, a patient-specific evaluation is warranted. In conclusion, MRI-based CFD offers an opportunity to assess the interactions between prosthesis and patient-specific boundary conditions, which may help in optimizing surgical decision making and providing additional guidance to clinicians. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Chen, Ming; Luo, Huai; Miyamoto, Takashi; Atar, Shaul; Kobal, Sergio; Rahban, Masoud; Brasch, Andrea V; Makkar, Rajendra; Neuman, Yoram; Naqvi, Tasneem Z; Tolstrup, Kirsten; Siegel, Robert J
2003-09-01
We assessed aortic regurgitation (AR) severity by utilizing multiple echo-Doppler variables in comparison with AR severity by aortic root angiography. Patients were divided into 3 groups: mild, moderate, and severe. An AR index (ARI) was developed, comprising 5 echocardiographic parameters: ratio of color AR jet height to left ventricular outlet flow diameter, AR signal density from continuous-wave Doppler, pressure half-time, left ventricular end-diastolic diameter, and aortic root diameter. There was a strong correlation between AR severity by angiography and the calculated echo-Doppler ARI (r = 0.84, p = 0.0001). As validated by aortic angiography, the ARI is an accurate reflection of AR severity.
Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K.; Goncalves, Alexandra; Di Carli, Marcelo F.; Rybicki, Frank J.; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron
2017-01-01
Background 3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. Objective To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). Methods This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Results Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of −0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Conclusions Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. PMID:26732862
Overview of current surgical strategies for aortic disease in patients with Marfan syndrome.
Miyahara, Shunsuke; Okita, Yutaka
2016-09-01
Marfan syndrome is a heritable, systemic disorder of the connective tissue with a high penetrance, named after Dr. Antoine Marfan. The most clinically important manifestations of this syndrome are cardiovascular pathologies which cause life-threatening events, such as acute aortic dissections, aortic rupture and regurgitation of the aortic valve or other artrioventricular valves leading to heart failure. These events play important roles in the life expectancy of patients with this disorder, especially prior to the development of effective surgical approaches for proximal ascending aortic disease. To prevent such catastrophic aortic events, a lower threshold has been recommended for prophylactic interventions on the aortic root. After prophylactic root replacement, disease in the aorta beyond the root and distal to the arch remains a cause for concern. Multiple surgeries are required throughout a patient's lifetime that can be problematic due to distal lesions complicated by dissection. Many controversies in surgical strategies remain, such as endovascular repair, to manage such complex cases. This review examines the trends in surgical strategies for the treatment of cardiovascular disease in patients with Marfan syndrome, and current perspectives in this field.
Nakamura, Kenta; Passeri, Jonathan J; Inglessis-Azuaje, Ignacio
2017-07-01
We report a case of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement and subsequent percutaneous closure. The diagnosis and treatment of this rare complication is illustrated through multi-modality imaging. We hypothesize that the patient's heavily calcified bicuspid aortic valve anatomy led to asymmetric deployment of the transcatheter aortic valve replacement (TAVR) prosthesis, traumatizing the right sinus of Valsalva at the distal edge of the TAVR stent and ultimately fistulized to the right ventricle. The patient acutely decompensated with heart failure five days after TAVR and underwent emergent intervention. The aorto-right ventricular fistula was closed using an 18-mm septal occluder device with marked clinical recovery. Transcatheter closure is a viable treatment option for acute aorto-right ventricular fistula. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Shibayama, Kentaro; Mihara, Hirotsugu; Jilaihawi, Hasan; Berdejo, Javier; Harada, Kenji; Itabashi, Yuji; Siegel, Robert; Makkar, Raj R; Shiota, Takahiro
2016-02-01
This study of 3-dimensional (3D) transesophageal echocardiography (TEE) aimed to demonstrate features associated with transvalvular aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) and to confirm the fact that a gap between the native aortic annulus and prosthesis is associated with paravalvular AR. The mechanism of AR after TAVR, particularly that of transvalvular AR, has not been evaluated adequately. All patients with severe aortic stenosis who underwent TAVR with the Sapien device (Edwards Lifesciences, Irvine, California) had 3D TEE of the pre-procedural native aortic annulus and the post-procedural prosthetic valve. In the 201 patients studied, the total AR was mild in 67 patients (33%), moderate in 21 patients (10%), and severe in no patients. There were 20 patients with transvalvular AR and 82 patients with paravalvular AR. Fourteen patients had both transvalvular and paravalvular AR. Patients with transvalvular AR had larger prosthetic expansion (p <0.05), a more elliptical prosthetic shape at the prosthetic commissure level (p <0.01) and more anti-anatomical position (p <0.001), which was defined as malposition of the prosthetic commissures in relation to the native commissures, than the patients without transvalvular AR. Age (odds ratio [OR]: 1.05; 95% confidence interval [CI]: 1.01 to 1.09; p < 0.05) and effective area oversizing (OR: 0.97; 95% CI: 0.93 to 0.99, p <0.05) were associated with mild or greater paravalvular AR. 3D TEE successfully demonstrated the features associated with transvalvular AR, such as large prosthetic expansion, elliptical prosthetic shape, and anti-anatomical position of prosthesis. Additionally, effective area oversizing was associated with paravalvular AR. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Aortic valve replacement in a patient with severe nickel allergy.
Lusini, Mario; Barbato, Raffaele; Spadaccio, Cristiano; Chello, Massimo
2011-11-01
Nickel allergy can raise clinical problems in patients undergoing cardiac surgery who require sternal closure with stainless steel wire. We describe the case of a 51-year-old woman with severe nickel allergy who underwent aortic valve replacement with a nickel-free ON-X prosthesis and sternal closure by Fiberwire # 2 suture without complications. Considering its biocompatibility and its mechanical characteristics including optimal strength and knot resistance, this suture might be a viable alternative in patients in which the use of stainless steel wire is contraindicated. © 2011 Wiley Periodicals, Inc.
Fredricks, Todd R; Benseler, Jeffrey S
2016-05-01
Bicuspid aortic valve disease (BAV) is the most common cardiac valve pathology. BAV is associated with aortic root disorders. The literature has few case reports identifying this condition during routine physical exam. A 42-yr-old military reservist flight medic presented for his annual military flight physical. He was found to have a faint cardiac murmur. His past family and medical history were remarkable for familial essential hypertension and being told at age 9 that he had a "murmur." He was referred for cardiology consultation, echocardiography, stress testing, and a computerized tomography angiogram (CTa), which identified BAV with a 4.3-cm aortic root aneurysm. A follow-up at 1 yr was recommended. In the interim he developed severe aortic valve insufficiency, a 4.6-cm aortic root aneurysm. The valve and aortic root were repaired and a single left anterior descending coronary artery lesion was bypassed during surgery. The flight medic made a full recovery but was not returned to flight status. This case emphasizes the importance of periodic reassessment by thorough history and careful cardiac auscultation during flight physicals. BAV aortopathy is an uncommon condition seen in the military aviation community. Most flight surgeons will not have the opportunity to identify it specifically via auscultation. This patient had over nine annual flight physicals prior to the one reported and no pathology was ever identified through routine auscultation. The potential role of point-of-care ultrasound (POCUS) for survey of vascular and valve status of aviation personnel merits further research.
Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.
Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi
2013-09-10
Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.
Patient-prosthesis mismatch in aortic valve replacement: really tolerable?
Fuster, Rafael García; Montero Argudo, José A; Albarova, Oscar Gil; Sos, Fernando Hornero; López, Sergio Cánovas; Codoñer, María Bueno; Buendía Miñano, José A; Albarran, Ignacio Rodríguez
2005-03-01
Several studies have demonstrated favorable results despite patient-prosthesis mismatch after aortic valve replacement with the use of third generation prostheses. Our aim was to determine whether this mismatch is always tolerable. A clinical-echocardiographic study has been performed in 339 consecutive patients who underwent aortic valve replacement because of aortic stenosis. In-hospital outcome and left ventricular mass index regression (1st month-1st year) were analyzed in the presence or absence of mismatch (indexed effective orifice area < or =0.85cm(2)/m(2)). The influence of high degrees of preoperative left ventricular mass on in-hospital mortality has also been evaluated. Left ventricular mass index was considered increased if the calculated value was over the superior quartile of the frequency distribution of all the values observed in both sexes. Mismatch was found in 38% of the patients. In the absence of mismatch, the absolute mass regression was proportional to the preoperative left ventricular mass. This regression was higher in patients with increased left ventricular mass indexed (vs not increased): -38.0+/-7.8 vs -8.8+/-4.7g/m(2), p<0.01 (1st month) and -67.7+/-16.9vs -23.5+/-6.7g/m(2), p<0.05 (1st year). Mass regression was impaired in the presence of mismatch, particularly, in patients with previously increased left ventricular mass: -8.2+/-11.6 vs -5.6+/-6.3g/m(2) (p=0.83) and -24.6+/-12.6 vs -11.7+/-10.5g/m(2) (p=0.54). This worse regression was reflected on a 100% incidence of residual hypertrophy at follow-up (1st month-1st year). In the presence of mismatch, increased ventricular mass was associated with higher mortality: 14.7% vs 2.1% (p<0.01). In the absence of mismatch, ventricular mass was not associated with mortality: 4.1 vs 2.5% (p=0.55). In patients with severe ventricular hypertrophy it may be important to elude patient-prosthesis mismatch to avoid a significant increase in mortality and improve ventricular mass regression. Mismatch may be tolerable in those patients with lesser degree of hypertrophy.
Semaan, Edouard; Markl, Michael; Chris Malaisrie, S.; Barker, Alex; Allen, Bradley; McCarthy, Patrick; Carr, James C.; Collins, Jeremy D.
2014-01-01
OBJECTIVE To provide a more complete characterization of aortic blood flow in patients following valve-sparing aortic root replacement (VSARR) compared with presurgical cohorts matched by tricuspid and bicuspid valve morphology, age and presurgical aorta size. METHODS Four-dimensional (4D) flow magnetic resonance imaging (MRI) was performed to analyse three-dimensional (3D) blood flow in the thoracic aorta of n = 13 patients after VSARR with reimplantation of native tricuspid aortic valve (TAV, n = 6) and bicuspid aortic valve (BAV, n = 7). Results were compared with presurgical age and aortic size-matched control cohorts with TAV (n = 10) and BAV (n = 10). Pre- and post-surgical aortic flow was evaluated using time-resolved 3D pathlines using a blinded grading system (0–2, 0 = small, 1 = moderate and 2 = prominent) analysing ascending aortic (AAo) helical flow. Systolic flow profile uniformity in the aortic root, proximal and mid-AAo was evaluated using a four-quadrant model. Further analysis in nine analysis planes distributed along the thoracic aorta quantified peak systolic velocity, retrograde fraction and peak systolic flow acceleration. RESULTS Pronounced AAo helical flow in presurgical control subjects (both BAV and TAV: helix grading = 1.8 ± 0.4) was significantly reduced (0.2 ± 0.4, P < 0.001) in cohorts after VSARR independent of aortic valve morphology. Presurgical AAo flow was highly eccentric for BAV patients but more uniform for TAV. VSARR resulted in less eccentric flow profiles. Systolic peak velocities were significantly (P < 0.05) increased in post-root repair BAV patients throughout the aorta (six of nine analysis planes) and to a lesser extent in TAV patients (three of nine analysis planes). BAV reimplantation resulted in significantly increased peak velocities in the proximal AAo compared with root repair with TAV (2.3 ± 0.6 vs 1.6 ± 0.4 m/s, P = 0.017). Post-surgical patients showed a non-significant trend towards higher systolic flow acceleration as a surrogate measure of reduced aortic compliance. CONCLUSIONS VSARR restored a cohesive flow pattern independent of native valve morphology but resulted in increased peak velocities throughout the aorta. 4D flow MRI methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing VSARR. PMID:24317086
Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio
2015-07-01
A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.
Stella, Stefano; Italia, Leonardo; Geremia, Giulia; Rosa, Isabella; Ancona, Francesco; Marini, Claudia; Capogrosso, Cristina; Giglio, Manuela; Montorfano, Matteo; Latib, Azeem; Margonato, Alberto; Colombo, Antonio; Agricola, Eustachio
2018-02-06
A 3D transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced. The system automatically configures a geometric model of the aortic root and performs quantitative analysis of these structures. We compared the measurements of the aortic annulus (AA) obtained by semi-automated 3D-TOE quantitative software and manual analysis vs. multislice computed tomography (MSCT) ones. One hundred and seventy-five patients (mean age 81.3 ± 6.3 years, 77 men) who underwent both MSCT and 3D-TOE for annulus assessment before transcatheter aortic valve implantation were analysed. Hypothetical prosthetic valve sizing was evaluated using the 3D manual, semi-automated measurements using manufacturer-recommended CT-based sizing algorithm as gold standard. Good correlation between 3D-TOE methods vs. MSCT measurements was found, but the semi-automated analysis demonstrated slightly better correlations for AA major diameter (r = 0.89), perimeter (r = 0.89), and area (r = 0.85) (all P < 0.0001) than manual one. Both 3D methods underestimated the MSCT measurements, but semi-automated measurements showed narrower limits of agreement and lesser bias than manual measurements for most of AA parameters. On average, 3D-TOE semi-automated major diameter, area, and perimeter underestimated the respective MSCT measurements by 7.4%, 3.5%, and 4.4%, respectively, whereas minor diameter was overestimated by 0.3%. Moderate agreement for valve sizing for both 3D-TOE techniques was found: Kappa agreement 0.5 for both semi-automated and manual analysis. Interobserver and intraobserver agreements for the AA measurements were excellent for both techniques (intraclass correlation coefficients for all parameters >0.80). The 3D-TOE semi-automated analysis of AA is feasible and reliable and can be used in clinical practice as an alternative to MSCT for AA assessment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2018. For permissions, please email: journals.permissions@oup.com.
Mas-Stachurska, Aleksandra; Siegert, Anna-Maria; Batlle, Monsterrat; Gorbenko Del Blanco, Darya; Meirelles, Thayna; Rubies, Cira; Bonorino, Fabio; Serra-Peinado, Carla; Bijnens, Bart; Baudin, Julio; Sitges, Marta; Mont, Lluís; Guasch, Eduard; Egea, Gustavo
2017-09-25
Marfan syndrome (MF) leads to aortic root dilatation and a predisposition to aortic dissection, mitral valve prolapse, and primary and secondary cardiomyopathy. Overall, regular physical exercise is recommended for a healthy lifestyle, but dynamic sports are strongly discouraged in MF patients. Nonetheless, evidence supporting this recommendation is lacking. Therefore, we studied the role of long-term dynamic exercise of moderate intensity on the MF cardiovascular phenotype. In a transgenic mouse model of MF ( Fbn1 C1039G/+ ), 4-month-old wild-type and MF mice were subjected to training on a treadmill for 5 months; sedentary littermates served as controls for each group. Aortic and cardiac remodeling was assessed by echocardiography and histology. The 4-month-old MF mice showed aortic root dilatation, elastic lamina rupture, and tunica media fibrosis, as well as cardiac hypertrophy, left ventricular fibrosis, and intramyocardial vessel remodeling. Over the 5-month experimental period, aortic root dilation rate was significantly greater in the sedentary MF group, compared with the wild-type group (∆mm, 0.27±0.07 versus 0.13±0.02, respectively). Exercise significantly blunted the aortic root dilation rate in MF mice compared with sedentary MF littermates (∆mm, 0.10±0.04 versus 0.27±0.07, respectively). However, these 2 groups were indistinguishable by aortic root stiffness, tunica media fibrosis, and elastic lamina ruptures. In MF mice, exercise also produced cardiac hypertrophy regression without changes in left ventricular fibrosis. Our results in a transgenic mouse model of MF indicate that moderate dynamic exercise mitigates the progression of the MF cardiovascular phenotype. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Cocchia, Rosangela; D’Andrea, Antonello; Conte, Marianna; Cavallaro, Massimo; Riegler, Lucia; Citro, Rodolfo; Sirignano, Cesare; Imbriaco, Massimo; Cappelli, Maurizio; Gregorio, Giovanni; Calabrò, Raffaele; Bossone, Eduardo
2017-01-01
Transcatheter aortic valve replacement (TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional data. Multi-Imaging modalities should be preferred for assessing the anatomy and the dimensions of the aortic valve and annulus before TAVR. Ultrasounds represent the first line tool in evaluation of this patients giving detailed anatomic description of aortic valve complex and allowing estimating with enough reliability the hemodynamic entity of valvular stenosis. Angiography should be used to assess coronary involvement and plan a revascularization strategy before the implant. Multislice computed tomography play a central role as it can give anatomical details in order to choice the best fitting prosthesis, evaluate the morphology of the access path and detect other relevant comorbidities. Cardiovascular magnetic resonance and positron emission tomography are emergent modality helpful in aortic stenosis evaluation. The aim of this review is to give an overview on TAVR clinical and technical aspects essential for adequate selection. PMID:28400918
Outcomes of Aortic Valve-Sparing Operations in Marfan Syndrome.
David, Tirone E; David, Carolyn M; Manlhiot, Cedric; Colman, Jack; Crean, Andrew M; Bradley, Timothy
2015-09-29
In many cardiac units, aortic valve-sparing operations have become the preferred surgical procedure to treat aortic root aneurysm in patients with Marfan syndrome, based on relatively short-term outcomes. This study examined the long-term outcomes of aortic valve-sparing operations in patients with Marfan syndrome. All patients with Marfan syndrome operated on for aortic root aneurysm from 1988 through 2012 were followed prospectively for a median of 10 years. Follow-up was 100% complete. Time-to-event analyses were calculated using the Kaplan-Meier method with log-rank test for comparisons. A total of 146 patients with Marfan syndrome had aortic valve-sparing operations. Reimplantation of the aortic valve was performed in 121 and remodeling of the aortic root was performed in 25 patients. Mean age was 35.7 ± 11.4 years and two-thirds were men. Nine patients had acute, 2 had chronic type A, and 3 had chronic type B aortic dissections before surgery. There were 1 operative and 6 late deaths, 5 caused by complications of dissections. Mortality rate at 15 years was 6.8 ± 2.9%, higher than the general population matched for age and sex. Five patients required reoperation on the aortic valve: 2 for endocarditis and 3 for aortic insufficiency. Three patients developed severe, 4 moderate, and 3 mild-to-moderate aortic insufficiency. Rate of aortic insufficiency at 15 years was 7.9 ± 3.3%, lower after reimplantation than remodeling. Nine patients developed new distal aortic dissections during follow-up. Rate of dissection at 15 years was 16.5 ± 3.4%. Aortic valve-sparing operations in patients with Marfan syndrome were associated with low rates of valve-related complications in long-term follow-up. Residual and new aortic dissections were the leading cause of death. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Woldendorp, Kei; Starra, Eric; Seco, Michael; Hendel, P Nicholas; Jeremy, Richmond W; Wilson, Michael K; Vallely, Michael P; Bannon, Paul G
2014-12-01
Composite valve-graft (CVG) replacement of the aortic root is a well-studied and recognised treatment for various aortic root conditions, including valvular disease with associated aortopathy. There have been few previous studies of the procedure in large numbers in an Australian setting. From January 2006 to June 2013, 246 successive patients underwent CVG root replacements at our institution. Mean age was 56.8 years, 85.4% were male, and 87 had evidence of bicuspid aortic valve. Indications for operation included ascending aortic aneurysm in 222 patients, annuloaortic ectasia in 67 patients, and aortic dissection in 38 patients. The overall unit 30-day mortality was 5.7%, including: elective 30-day mortality of 2.2%, and emergent 30-day mortality of 17.2%. Statistically significant multivariate predictors of 30-day mortality were: acute aortic dissection (OR=20.07), peripheral vascular disease (OR=11.17), new ventricular tachycardia (OR=30.17), re-operation for bleeding (OR=14.42), concomitant mitral stenosis (OR=68.30), and cerebrovascular accident (OR=144.85). Low postoperative mortality in our series matches closely with results from similar sized international studies, demonstrating that this procedure can be performed with low risk in centres with sufficient experience in the operative procedure. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K; Goncalves, Alexandra; Di Carli, Marcelo F; Rybicki, Frank J; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron
2016-01-01
3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Reference Values of Aortic Root in Male and Female White Elite Athletes According to Sport.
Boraita, Araceli; Heras, Maria-Eugenia; Morales, Francisco; Marina-Breysse, Manuel; Canda, Alicia; Rabadan, Manuel; Barriopedro, Maria-Isabel; Varela, Amai; de la Rosa, Alejandro; Tuñón, José
2016-10-01
There is limited information regarding the aortic root upper physiological limits in all planes in elite athletes according to static and dynamic cardiovascular demands and sex. A cross-sectional study was performed in 3281 healthy elite athletes (2039 men and 1242 women) aged 23.1±5.7 years, with body surface area of 1.9±0.2 m 2 and 8.9±4.9 years and 19.2±9.6 hours/week of training. Maximum end-diastolic aortic root diameters were measured in the parasternal long axis by 2-dimensional echocardiography. Age, left ventricular mass, and body surface area were the main predictors of aortic dimensions. Raw values were greater in males than in females (P<0.0001) at all aortic root levels. Dimensions corrected by body surface area were higher in men than in women at the aortic annulus (13.1±1.7 versus 12.9±1.7 mm/m 2 ; P=0.007), without significant differences at the sinus of Valsalva (16.3±1.9 versus 16.3±1.9 mm/m 2 ; P=0.797), and were smaller in men at the sinotubular junction (13.6±1.8 versus 13.8±1.8 mm/m 2 ; P=0.008) and the proximal ascending aorta (13.8±1.9 versus 14.1±1.9 mm/m 2 ; P=0.001). Only 1.8% of men and 1.5% of women had values >40 mm and 34 mm, respectively. Raw and corrected aortic measures at all levels were significantly greater in sports, with a high dynamic component in both sexes, except for corrected values of the sinotubular junction in women. Aortic root dimensions in healthy elite athletes are within the established limits for the general population. This study describes the normal dimensions for healthy elite athletes classified according to sex and dynamic and static components of their sports. © 2016 American Heart Association, Inc.
Smíd, Michal; Ferda, Jirí; Baxa, Jan; Cech, Jakub; Hájek, Tomás; Kreuzberg, Boris; Rokyta, Richard
2010-04-01
Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Furukawa, Nobuyuki; Scholtz, Werner; Haas, Nikolaus; Ensminger, Stephan; Gummert, Jan; Börgermann, Jochen
2015-01-01
An 81-year-old man with high-grade aortic valve stenosis and status post-coronary artery bypass grafting and supracoronary replacement of the ascending aorta was referred for transcatheter aortic valve implantation. He was in New York Heart Association class III and had dyspnea. After appropriate screening, we implanted a 29-mm SAPIEN XT valve (Edwards Lifesciences, Irvine, CA USA) through a transapical approach because of severe peripheral arterial occlusive disease. Postinterventional aortography revealed correct positioning and function of the valve and free coronary ostia but contrast extravasation in the vicinity of the interposed vascular prosthesis, resulting in severe luminal narrowing. We chose to manage the stenosis with an endovascular stent. After stenting, extravascular compression was markedly reduced, and the pressure gradient disappeared. The patient was discharged home on the 20th postoperative day. Three months later, computed tomography depicted correct positioning of both grafts. The patient's general health is good, and he is now in New York Heart Association class II. This case illustrates a complication of transcatheter aortic valve implantation specific for patients with an ascending aortic graft. Although stenting may be a good solution, as depicted by this case, self-expanding transcatheter aortic valves should be preferred in patients with ascending aortic grafts to avoid the described complication.
Rupture of an Abdominal Aortic Aneurysm in a Young Man with Marfan Syndrome.
Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren; Nielsen, Dorte Guldbrand; Andersen, Niels Holmark
2018-04-01
Abdominal aortic aneurysms (AAAs) are very rare in Marfan syndrome. We present a case with a young nonsmoking and normotensive male with Marfan syndrome, who developed an infrarenal AAA that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock. The patient had acute aortic surgery and survived. Five months before this incident, the patient had uneventful elective aortic root replacement (ad modum David) due to an enlarged aortic root. At that time, his abdominal aorta was assessed with a routine ultrasound scan that showed a normal-sized abdominal aorta. This documents that the aneurysm had evolved very rapidly despite young age and absence of risk factors. Copyright © 2018 Elsevier Inc. All rights reserved.
Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.
Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P
2008-08-01
The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.
Recent Clinical Drug Trials Evidence in Marfan Syndrome and Clinical Implications.
Singh, Michael N; Lacro, Ronald V
2016-01-01
Marfan syndrome is a genetic disorder of connective tissue with principal manifestations in the cardiovascular, ocular, and skeletal systems. Cardiovascular disease, mainly progressive aortic root dilation and aortic dissection, is the leading cause of morbidity and mortality. The primary aims of this report were to examine the evidence related to medical therapy for Marfan syndrome, including recently completed randomized clinical trials on the efficacy of β-blockers and angiotensin II receptor blockers for the prophylactic treatment of aortic enlargement in Marfan syndrome, and to provide recommendations for medical therapy on the basis of available evidence. Medical therapy for Marfan syndrome should be individualized according to patient tolerance and risk factors such as age, aortic size, and family history of aortic dissection. The Pediatric Heart Network trial showed that atenolol and losartan each reduced the rate of aortic dilation. All patients with known or suspected Marfan syndrome and aortic root dilation should receive medical therapy with adequate doses of either β-blocker or angiotensin receptor blocker. The Pediatric Heart Network trial also showed that atenolol and losartan are more effective at reduction of aortic root z score in younger subjects, which suggests that medical therapy should be prescribed even in the youngest children with aortic dilation. For patients with Marfan syndrome without aortic dilation, the available evidence is less clear. If aortic dilation is severe and/or progressive, therapy with a combination of β-blocker and angiotensin receptor blocker should be considered, although trial results are mixed with respect to the efficacy of combination therapy vs monotherapy. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Twenty-year analysis of autologous support of the pulmonary autograft in the Ross procedure.
Skillington, Peter D; Mokhles, M Mostafa; Takkenberg, Johanna J M; O'Keefe, Michael; Grigg, Leeanne; Wilson, William; Larobina, Marco; Tatoulis, James
2013-09-01
The Ross procedure is seldom offered to adults less than 60 years of age who require aortic valve replacement except in a few high-volume centers with documented expertise. Inserting the pulmonary autograft as an unsupported root replacement may lead to increasing reoperations on the aortic valve in the second decade. Of 333 patients undergoing the Ross procedure between October 1992 and June 2012, the study group of 310 consecutive patients (mean age ± standard deviation, 39.3±12.7 years (limits 16-63) had the aortic root size adjusted to match the pulmonary autograft, which was inserted as a root replacement, with the aorta closed up around it to provide autologous support. The mean follow-up time was 9.4 years; the actuarial survival was 97% at 16 years; and freedom from the composite of all reoperations on the aortic valve and late echocardiographic-detected aortic regurgitation greater than mild was 95% at 5 years, 94% at 10 years, and 93% at 15 years. Overall freedom from all reoperations on aortic and pulmonary valves was 97% at 5 years, 94% at 10 years, and 93% at 15 years. All results were better for the patients presenting with predominant aortic stenosis (98% freedom at 15 years) than for those with aortic regurgitation (p=0.01). Autologous support of the pulmonary autograft leads to excellent results in the groups presenting with aortic stenosis and mixed aortic stenosis/regurgitation and to good results for those presenting with pure aortic regurgitation. The Ross procedure, using one of the proven, durable techniques available, should be considered for more widespread adoption. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Short-term and mid-term results with the Sorin Freedom Solo aortic valve.
Ustunsoy, Hasim; Yasim, Alptekin; Deniz, Hayati; Gokaslan, Gokhan; Ozcaliskan, Ozerdem
2013-03-01
The study aim was to present the short- and mid-term results for patients who underwent aortic valve replacement (AVR) with the Sorin Freedom Solo third-generation stentless prosthetic valve. AVR with a Sorin Freedom Solo valve was performed in 14 patients between March 2006 and March 2011. Patients aged > or = 60 years (male:female ratio 6:8; mean age 73.28 +/- 5.42 years) who required AVR with the Sorin Freedom Solo valve according to the surgeon's choice were included in the study. The valvular prosthesis was implanted in the supra-annular position, using a single suture line. Eight patients underwent an isolated AVR; combined interventions were carried out in the other patients due to concomitant cardiac disease. One patient died during the immediate perioperative period, and two more during the follow up, from non-cardiac causes. The mean maximum transvalvular gradient of patients with aortic stenosis was 88.1 +/- 20.2 mmHg, and this fell to 26.4 +/- 7.6 mmHg during the early postoperative period. The mean gradient at one year of follow up was further decreased to 19.4 +/- 5.3 mmHg. The left ventricular end-diastolic and end-systolic diameters were also significantly reduced, from 4.8 +/- 0.9 to 4.3 +/- 0.6 cm and from 3.2 +/- 0.6 to 2.8 +/- 5.3 cm, respectively. The average left ventricular ejection fraction was 60.2 +/- 4.9% preoperatively, and 63.2 +/- 2.1% at one year after surgery (p = NS). No paravalvular leakage, endocarditis, prosthesis failure or neurologic events were reported among patients. The Sorin Freedom Solo stentless valve has provided good early and intermediate-term results. Implantation of the prosthesis is straightforward, with low rates of morbidity and mortality. However, these data require further support from larger patient series and long-term follow up.
Trans-catheter aortic valve implantation after previous aortic homograft surgery.
Drews, Thorsten; Pasic, Miralem; Buz, Semih; Unbehaun, Axel
2011-12-01
In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Schlingloff, Friederike; Schäfer, Ulrich; Frerker, Christian; Schmoeckel, Michael; Bader, Ralf
2014-09-01
The second-generation Jenavalve prosthesis (Jenavalve Technology, Inc., Munich, Germany) is the first transcatheter valve Conformité Européene (CE) marked for treatment of both aortic stenosis (AS) and pure aortic regurgitation (AR). Although the feasibility of the Jenavalve transcatheter aortic valve implantation (TAVI) in patients with pure AR has been described, haemodynamic and follow-up data are lacking. We report on a series of 10 transapical Jenavalve implantations for pure AR between December 2012 and September 2013. The patients were determined for TAVI by heart team decision at high surgical risk [log EuroSCORE (European System for Cardiac Operative Risk Evaluation) >20%], frailty or Charlson Comorbidity Index (CCI). Transaortic gradients and right heart haemodynamics were measured invasively before and after TAVI. Ventriculography and transoesophageal echocardiography were used to determine paravalvular regurgitation. All-cause mortality, NYHA functional class and echocardiographic measurements were followed up at 30 days and at 3, 9 and 12 months postoperatively. Overall, mean age was 79 ± 9 years, mean left ventricular ejection fraction 50 ± 17% and mean log EuroSCORE 28.3 ± 17.1%. There were no perioperative complications. Paravalvular regurgitation immediately after implantation was graded none (n = 6), trace (n = 3) or mild (n = 1). Overall 30-day mortality was 30% (3/10). Three patients refused further treatment, such as haemodialysis or treatment of mitral regurgitation. Rate for pacemaker implantation was 2/10 (20%). Intraprocedural success and haemodynamic data in our cases were good. The mortality in our group highlighted the importance of careful patient selection, especially for this pathology. The Jenavalve prosthesis proved to be suitable for treatment of AR in surgical high-risk patients. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
O’Brien, Stephen; Dayer, Mark; Benzimra, James; Hardman, Susan; Townsend, Mandie
2011-01-01
A 63-year-old woman with a previous episode of Streptococcus agalactiae endocarditis requiring a bioprosthetic aortic valve replacement presented with a short history of malaise, a right panopthalmitis with a Roth spot on funduscopy of the left eye and Streptococcus pneumoniae grown from vitreous and aqueous taps as well as blood cultures. She developed first degree heart block and her ECG was suggestive of an aortic root abscess. This gradually resolved over 6 weeks, during which she was treated with intravenous antibiotics. After careful consideration, it is likely that what was thought to be an aortic root abscess was instead an area of perivalvular inflammation. PMID:22678733
Grotenhuis, Heynric B; Ottenkamp, Jaap; Fontein, Duveken; Vliegen, Hubert W; Westenberg, Jos J M; Kroft, Lucia J M; de Roos, Albert
2008-12-01
To prospectively assess aortic dimensions, aortic elasticity, aortic valve competence, and left ventricular (LV) systolic function in patients after the arterial switch operation (ASO) by using magnetic resonance (MR) imaging. Informed consent was obtained from all participants for this local ethics committee-approved study. Fifteen patients (11 male patients, four female patients; mean age, 16 years +/- 4 [standard deviation]; imaging performed 16.1 years after surgery +/- 3.7) and 15 age- and sex-matched control subjects (11 male subjects, four female subjects; mean age, 16 years +/- 4) were evaluated. Velocity-encoded MR imaging was used to assess aortic pulse wave velocity (PWV), and a balanced turbo-field-echo sequence was used to assess aortic root distensibility. Standard velocity-encoded and multisection-multiphase imaging sequences were used to assess aortic valve function, systolic LV function, and LV mass. The two-tailed Mann-Whitney U test and Spearman rank correlation coefficient were used for statistical analysis. Patients treated with the ASO showed aortic root dilatation at three predefined levels (mean difference, 5.7-9.4 mm; P < or = .007) and reduced aortic elasticity (PWV of aortic arch, 5.1 m/sec +/- 1.2 vs 3.9 m/sec +/- 0.7, P = .004; aortic root distensibility, [2.2 x 10(-3)] x mm Hg(-1) +/- 1.8 vs [4.9 x 10(-3)] x mm Hg(-1) +/- 2.9, P < .01) compared with control subjects. Minor degrees of aortic regurgitation (AR) were present (AR fraction, 5% +/- 3 in patients vs 1% +/- 1 in control subjects; P < .001). Patients had impaired systolic LV function (LV ejection fraction [LVEF], 51% +/- 6 vs 58% +/- 5 in control subjects; P = .003), in addition to enlarged LV dimensions (end-diastolic volume [EDV], 112 mL/m(2) +/- 13 vs 95 mL/m(2) +/- 16, P = .007; end-systolic volume [ESV], 54 mL/m(2) +/- 11 vs 39 mL/m(2) +/- 7, P < .001). Degree of AR predicted decreased LVEF (r = 0.41, P = .026) and was correlated with increased LV dimensions (LV EDV: r = 0.48, P = .008; LV ESV: r = 0.67, P < .001). Aortic root dilatation and reduced elasticity of the proximal aorta are frequently observed in patients who have undergone the ASO, in addition to minor degrees of AR, reduced LV systolic function, and increased LV dimensions. RSNA, 2008
Ruile, Philipp; Blanke, Philipp; Krauss, Tobias; Dorfs, Stephan; Jung, Bernd; Jander, Nikolaus; Leipsic, Jonathon; Langer, Mathias; Neumann, Franz-Josef; Pache, Gregor
2016-04-01
To evaluate the feasibility of a non-contrast three-dimensional (3D)-FLASH magnetic resonance angiography (MRA) protocol for pre-procedural aortic annulus assessment for transcatheter aortic valve replacement (TAVR) in comparison with cardiac dual-source computed tomography angiography (CTA). In this prospective study, 69 of 104 consecutive patients (mean age 81.8 ± 5.4 years, 37.7% arrhythmic) with severe aortic stenosis who had undergone pre-TAVR cardiac CTA received a respiratory and ECG-triggered, non-contrast 3D-FLASH MRA at 3 T. Annular area measurements were obtained at mid-diastole for both modalities whereas maximum systolic area was assessed by CTA only. Systolic MRA dimensions were modelled, by adding the relative difference of systolic and diastolic CTA area dimensions as a corrective factor. Hypothetical prosthesis sizing was performed based on systolic CTA, diastolic, and modelled systolic MRA area measurements. MR image quality and degree of annular calcifications were evaluated using 4-point-grading scales. The mean acquisition time was 14 ± 4.2 min. The mean image quality was 3.1 ± 0.9 with only two examinations rated non-diagnostic. The mean degree of calcifications was equal. As assessed by Bland-Altman analysis, there was no relevant systematic difference between area measurements for modelled systolic MRA and systolic CTA [the mean difference -3.1 mm(2) (limits of agreement -44.4 mm(2); 38.2 mm(2))]. Agreement for hypothetical prosthesis sizing was found in 63 of 67 (94%) patients for systolic CTA and modelled systolic MRA. The employed non-contrast 3D-FLASH MRA protocol allows for reliable assessment of aortic annulus dimensions and calcifications even in the presence of arrhythmias in an all-comers pre-TAVR population. Implementation of this technique appears legitimate in patients at an increased risk for contrast-induced nephropathy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Dietary fatty acids on aortic root calcification in mice with metabolic syndrome.
Naranjo, Maria C; Bermudez, Beatriz; Garcia, Indara; Lopez, Sergio; Abia, Rocio; Muriana, Francisco J G; Montserrat-de la Paz, Sergio
2017-04-19
Metabolic syndrome (MetS) is associated with obesity, dyslipidemia, type 2 diabetes, and chronic low-grade inflammation. The aim of this study was to determine the role of high-fat low-cholesterol diets (HFLCDs) rich in SFAs (HFLCD-SFAs), MUFAs (HFLCD-MUFAs) or MUFAs plus omega-3 long-chain PUFAs (HFLCD-PUFAs) on vascular calcification by the modulation of the RANKL/RANK/OPG system in the aortic roots of Lep ob/ob LDLR -/- mice. Animals fed with HFLCD-SFAs had increased weight and a greater atheroma plaque size, calcification, and RANKL/CATHK expression in the aortic root than mice on MUFA-enriched diets, with an increasing OPG expression in the aortic roots of the latter. Our study demonstrates that compared to dietary SFAs, MUFAs from olive oil protect against atherosclerosis by interfering with vascular calcification via the RANKL/RANK/OPG system in the setting of MetS. These findings open opportunities for developing novel nutritional strategies with olive oil as the most important dietary source of MUFAs (notably oleic acid) to prevent cardiovascular complications in MetS.
Rapid prototyping of compliant human aortic roots for assessment of valved stents.
Kalejs, Martins; von Segesser, Ludwig Karl
2009-02-01
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.
Aortic valve repair using a differentiated surgical strategy.
Langer, Frank; Aicher, Diana; Kissinger, Anke; Wendler, Olaf; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim
2004-09-14
Reconstruction of the aortic valve for aortic regurgitation (AR) remains challenging, in part because of not only cusp or root pathology but also a combination of both can be responsible for this valve dysfunction. We have systematically tailored the repair to the individual pathology of cusps and root. Between October 1995 and August 2003, aortic valve repair was performed in 282 of 493 patients undergoing surgery for AR and concomitant disease. Root dilatation was corrected by subcommissural plication (n=59), supracommissural aortic replacement (n=27), root remodeling (n=175), or valve reimplantation within a graft (n=24). Cusp prolapse was corrected by plication of the free margin (n=157) or triangular resection (n =36), cusp defects were closed with a pericardial patch (n=16). Additional procedures were arch replacement (n=114), coronary artery bypass graft (n=60) or mitral repair (n=24). All patients were followed-up (follow-up 99.6% complete), and cumulative follow-up was 8425 patient-months (mean, 33+/-27 months).Results- Eleven patients died in hospital (3.9%). Nine patients underwent reoperation for recurrent AR (3.3%). Actuarial freedom from AR grade > or =II at 5 years was 81% for isolated valve repair, 84% for isolated root replacement, and 94% for combination of both; actuarial freedom from reoperation at 5 years was 93%, 95%, and 98%, respectively. No thromboembolic events occurred, and there was 1 episode of endocarditis 4.5 years postoperatively. Aortic valve repair is feasible even for complex mechanisms of AR with a systematic and individually tailored approach. Operative mortality is low and mid-term durability is encouraging. The incidence of valve-related morbidity is low compared with valve replacement.
Bolen, Michael A; Popovic, Zoran B; Dahiya, Arun; Kapadia, Samir R; Tuzcu, E Murat; Flamm, Scott D; Halliburton, Sandra S; Schoenhagen, Paul
2012-01-01
Transcatheter valve interventions rely on imaging for patient selection, preprocedural planning, and intraprocedural guidance. We explored the use of prospective electrocardiogram (ECG)-triggered 4-dimensional (4-D) CT imaging in patients evaluated for transcatheter aortic valve replacement (TAVR). A total of 47 consecutive patients underwent 128-slice dual-source CT with wide-window dose-modulated prospective ECG-triggered, axial acquisition of the aortic root, reconstructed during diastolic and systolic cardiac phases. Image quality was evaluated, aortic root and left ventricular (LV) geometry and function were analyzed, and radiation exposure was estimated. Image quality was generally good, with 41 of 47 (87%) patients scored as good or excellent. The mean aortic valve area was 0.93 ± 0.24 cm(2). Mean LV ejection fraction was 56.8% ± 16.4%, and mean LV mass was 130.4 ± 43.8 g. The minor diameter of the annulus was larger in systole (systole, 2.29 ± 0.24 cm; diastole, 2.14 ± 0.25 cm; P = 0.006), but the mean and major diameters did not vary significantly between systole and diastole. The mean estimated effective dose was 5.9 ± 2.4 mSv. Multiphase, prospective ECG-triggered axial image acquisition is a lower dose acquisition technique for 4-D aortic root imaging in patients being considered for TAVR. Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Early signs that predict later haemodynamically significant patent ductus arteriosus.
Engür, Defne; Deveci, Murat; Türkmen, Münevver K
2016-03-01
Our aim was to determine the optimal cut-off values, sensitivity, specificity, and diagnostic power of 12 echocardiographic parameters on the second day of life to predict subsequent ductal patency. We evaluated preterm infants, born at ⩽32 weeks of gestation, starting on their second day of life, and they were evaluated every other day until ductal closure or until there were clinical signs of re-opening. We measured transductal diameter; pulmonary arterial diastolic flow; retrograde aortic diastolic flow; pulsatility index of the left pulmonary artery and descending aorta; left atrium and ventricle/aortic root ratio; left ventricular output; left ventricular flow velocity time integral; mitral early/late diastolic flow; and superior caval vein diameter and flow as well as performed receiver operating curve analysis. Transductal diameter (>1.5 mm); pulmonary arterial diastolic flow (>25.6 cm/second); presence of retrograde aortic diastolic flow; ductal diameter by body weight (>1.07 mm/kg); left pulmonary arterial pulsatility index (⩽0.71); and left ventricle to aortic root ratio (>2.2) displayed high sensitivity and specificity (p0.9). Parameters with moderate sensitivity and specificity were as follows: left atrial to aortic root ratio; left ventricular output; left ventricular flow velocity time integral; and mitral early/late diastolic flow ratio (p0.05) had low diagnostic value. Left pulmonary arterial pulsatility index, left ventricle/aortic root ratio, and ductal diameter by body weight are useful adjuncts offering a broader outlook for predicting ductal patency.
Yim, Eugene S; Kao, Daniel; Gillis, Edward F; Basilico, Frederick C; Corrado, Gianmichael D
2013-12-01
The purpose of this study was to investigate whether sports medicine physicians can obtain accurate measurements of the aortic root in young athletes. Twenty male collegiate athletes, aged 18 to 21 years, were prospectively enrolled. Focused echocardiography was performed by a board-certified sports medicine physician and a medical student, followed by comprehensive echocardiography within 2 weeks by a cardiac sonographer. A left parasternal long-axis view was acquired to measure the aortic root diameter at the sinuses of Valsalva. Intraclass correlation coefficients (ICCs) were used to assess inter-rater reliability compared to a reference standard and intra-rater reliability of repeated measurements obtained by the sports medicine physician and medical student. The ICCs between the sports medicine physician and cardiac sonographer and between the medical student and cardiac sonographer were strong: 0.80 and 0.76, respectively. Across all 3 readers, the ICC was 0.89, indicating strong inter-rater reliability and concordance. The ICC for the 2 measurements taken by the sports medicine physician for each athlete was 0.75, indicating strong intra-rater reliability. The medical student had moderate intra-rater reliability, with an ICC of 0.59. Sports medicine physicians are able to obtain measurements of the aortic root by focused echocardiography that are consistent with those obtained by a cardiac sonographer. Focused physician-performed echocardiography may serve as a promising technique for detecting aortic root dilatation and may contribute in this manner to preparticipation cardiovascular screening for athletes.
Guri, Amir J.; Misyak, Sarah A.; Hontecillas, Raquel; Hasty, Alyssa; Liu, Dongmin; Si, Hongwei; Bassaganya-Riera, Josep
2009-01-01
Abscisic acid (ABA) is a natural phytohormone which improves insulin sensitivity and reduces adipose tissue inflammation when supplemented into diets of obese mice. The objective of this study was to investigate the mechanisms by which abscisic acid (ABA) prevents or ameliorates atherosclerosis. Apolipoprotein E-deficient (ApoE −/−) mice were fed high-fat diets with or without ABA for 84 days. Systolic blood pressure was assessed on days 0, 28, 56, and 72. Gene expression, immune cell infiltration, and histological lesions were evaluated in the aortic root wall. Human aortic endothelial cells were used to examine the effect of ABA on 3’, 5’-cyclic adenosine monophosphate (cAMP) and nitric oxide (NO) production in vitro. We report that ABA-treated mice had significantly improved systolic blood pressure and decreased accumulation of F4/80+CD11b+ macrophages and CD4+ T cells in aortic root walls. At the molecular level, ABA significantly enhanced aortic endothelial nitric oxide synthase (eNOS) and tended to suppress aortic vascular cell adhesion molecule-1 (VCAM-1) and monocyte chemoattractant protein-1 (MCP-1) expression and plasma MCP-1 concentrations. ABA also caused a dose-dependent increase in intracellular concentrations of cAMP and NO and upregulated eNOS mRNA expression in human aortic endothelial cells. This is the first report showing that ABA prevents or ameliorates atherosclerosis-induced hypertension, immune cell recruitment into the aortic root wall, and upregulates aortic eNOS expression in ApoE−/− mice. PMID:20092994
Guri, Amir J; Misyak, Sarah A; Hontecillas, Raquel; Hasty, Alyssa; Liu, Dongmin; Si, Hongwei; Bassaganya-Riera, Josep
2010-12-01
Abscisic acid (ABA) is a natural phytohormone which improves insulin sensitivity and reduces adipose tissue inflammation when supplemented into diets of obese mice. The objective of this study was to investigate the mechanisms by which ABA prevents or ameliorates atherosclerosis. apolipoprotein E-deficient (ApoE(-/-)) mice were fed high-fat diets with or without ABA for 84 days. Systolic blood pressure was assessed on Days 0, 28, 56 and 72. Gene expression, immune cell infiltration and histological lesions were evaluated in the aortic root wall. Human aortic endothelial cells were used to examine the effect of ABA on 3',5'-cyclic adenosine monophosphate (cAMP) and nitric oxide (NO) production in vitro. We report that ABA-treated mice had significantly improved systolic blood pressure and decreased accumulation of F4/80(+)CD11b(+) macrophages and CD4(+) T cells in aortic root walls. At the molecular level, ABA significantly enhanced aortic endothelial nitric oxide synthase (eNOS) and tended to suppress aortic vascular cell adhesion molecule-1 (VCAM-1) and monocyte chemoattractant protein-1 (MCP-1) expression and plasma MCP-1 concentrations. ABA also caused a dose-dependent increase in intracellular concentrations of cAMP and NO and up-regulated eNOS mRNA expression in human aortic endothelial cells. This is the first report showing that ABA prevents or ameliorates atherosclerosis-induced hypertension, immune cell recruitment into the aortic root wall and up-regulates aortic eNOS expression in ApoE(-/-) mice. Copyright © 2010 Elsevier Inc. All rights reserved.
Aortic cusp extension for surgical correction of rheumatic aortic valve insufficiency in children.
Kalangos, Afksendiyos; Myers, Patrick O
2013-10-01
Surgical management of aortic insufficiency in the young is problematic because of the lack of an ideal valve substitute. Potential advantages of aortic valve repair include low incidences of thromboembolism and endocarditis, avoiding conduit replacements, the maintenance of growth potential, and improved quality of life. Aortic valve repair is still far from fulfilling the three key factors that have allowed the phenomenal development of mitral valve repair (standardization, reproducibility, and stable long-term results); however, techniques of aortic valve repair have been refined, and subsets of patients amenable to repair have been identified. We have focused on the oldest technique of aortic valve repair, cusp extension, focusing on children with rheumatic aortic insufficiency. Among 77 children operated from 2003 to 2007, there was one early death from ventricular failure and one late death from sudden cardiac arrhythmia. During a mean follow-up of 12.8 ± 5.9 years, there were 16 (20.5%) reoperations on the aortic valve, at a median of 3.4 years (range, 2 months to 18.3 years) from repair. Freedom from aortic valve reoperation was 96.2% ± 2.2% at 1 year, 94.9% ± 2.5% at 2 years, 88.5% ± 3.6% at 5 years, 81.7% ± 4.4% at 10 years, 79.7% ± 4.8% at 15 years, and 76.2% ± 5.7% at 20 years. Although aortic cusp extension is technically more demanding, it remains particularly more suitable in the context of evolving rheumatic aortic insufficiency in children with a small aortic annulus as a bridge surgical approach to late aortic valve replacement with a larger valvular prosthesis.
Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S
2016-04-01
In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Reoperation for composite valve graft failure: Operative results and midterm survival.
Maroto, Luis C; Carnero, Manuel; Cobiella, Javier; García, Mónica; Vilacosta, Isidre; Reguillo, Fernando; Villagrán, Enrique; Olmos, Carmen
2018-06-01
The replacement of a failed composite valve graft is technically more demanding and is associated with increased morbidity and mortality. We present our technique and outcomes for reoperations for composite graft failures. Between September 2011 and June 2017, 14 patients underwent a redo composite graft replacement. Twelve patients (85.7%) were male, and mean age was 58.4 years ± 12 standard deviation (SD). One patient had two previous root replacements. Indications for reoperation were endocarditis (8), aortic pseudoaneurysm (3), and aortic prosthesis thrombosis (3). Mean logistic EuroSCORE and EuroSCORE II were 30.8% and 14.7%, respectively. A mechanical composite graft was used in 12 patients and biological composite grafts were used in two patients. Hospital mortality was 14.3% (n = 2). One patient (7.1%) required reoperation for bleeding, One patient (7.1%) had mechanical ventilation >24 h, and four patients (28.6%) required implantation of a permanent pacemaker. Median intensive care unit and hospital stays were 3 days (interquartile range [IQR] 1-5) and 10 days (IQR 6.5-38.5). One patient experienced recurrent prosthetic valve endocarditis 14 months after operation. On follow-up, 11 of 12 survivors were in New York Heart Association class I or II. Survival at 3 years was 85.7% ± 9.4% SD. Composite valve graft replacement can be performed with acceptable morbidity and mortality with good mid-term survival. © 2018 Wiley Periodicals, Inc.
A Rare Cause of Endocarditis: Streptococcus pyogenes
Yeşilkaya, Ayşegül; Azap, Özlem Kurt; Pirat, Bahar; Gültekin, Bahadır; Arslan, Hande
2012-01-01
Although group A β-hemolytic streptococcus is an uncommon cause of infective endocarditis, an increase in the incidence of invasive group A streptococcus infections including bacteremia has been reported in the last two decades. Herein we report Streptococcus pyogenes endocarditis in a previously healthy adult patient who was hospitalized to investigate the etiology of fever. Because of a suspicion of a new vegetation appeared in the second (aortic) valve in the 14th day of high dose penicillin G treatment, the mitral and aortic valves were replaced by mechanical prosthesis on the 22nd day of treatment. He was discharged from hospital after the 6 week course of antibiotic treatment. PMID:25207027
A Rare Cause of Endocarditis: Streptococcus pyogenes.
Yeşilkaya, Ayşegül; Azap, Ozlem Kurt; Pirat, Bahar; Gültekin, Bahadır; Arslan, Hande
2012-09-01
Although group A β-hemolytic streptococcus is an uncommon cause of infective endocarditis, an increase in the incidence of invasive group A streptococcus infections including bacteremia has been reported in the last two decades. Herein we report Streptococcus pyogenes endocarditis in a previously healthy adult patient who was hospitalized to investigate the etiology of fever. Because of a suspicion of a new vegetation appeared in the second (aortic) valve in the 14(th) day of high dose penicillin G treatment, the mitral and aortic valves were replaced by mechanical prosthesis on the 22(nd) day of treatment. He was discharged from hospital after the 6 week course of antibiotic treatment.
Sex, pregnancy and aortic disease in Marfan syndrome.
Renard, Marjolijn; Muiño-Mosquera, Laura; Manalo, Elise C; Tufa, Sara; Carlson, Eric J; Keene, Douglas R; De Backer, Julie; Sakai, Lynn Y
2017-01-01
Sex-related differences as well as the adverse effect of pregnancy on aortic disease outcome are well-established phenomena in humans with Marfan syndrome (MFS). The underlying mechanisms of these observations are largely unknown. In an initial (pilot) step we aimed to confirm the differences between male and female MFS patients as well as between females with and without previous pregnancy. We then sought to evaluate whether these findings are recapitulated in a pre-clinical model and performed in-depth cardiovascular phenotyping of mutant male and both nulliparous and multiparous female Marfan mice. The effect of 17β-estradiol on fibrillin-1 protein synthesis was compared in vitro using human aortic smooth muscle cells and fibroblasts. Our small retrospective study of aortic dimensions in a cohort of 10 men and 20 women with MFS (10 pregnant and 10 non-pregnant) confirmed that aortic root growth was significantly increased in the pregnant group compared to the non-pregnant group (0.64mm/year vs. 0.12mm/year, p = 0.018). Male MFS patients had significantly larger aortic root diameters compared to the non-pregnant and pregnant females at baseline and follow-up (p = 0.002 and p = 0.007, respectively), but no significant increase in aortic root growth was observed compared to the females after follow-up (p = 0.559 and p = 0.352). In the GT-8/+ MFS mouse model, multiparous female Marfan mice showed increased aortic diameters when compared to nulliparous females. Aortic dilatation in multiparous females was comparable to Marfan male mice. Moreover, increased aortic diameters were associated with more severe fragmentation of the elastic lamellae. In addition, 17β-estradiol was found to promote fibrillin-1 production by human aortic smooth muscle cells. Pregnancy-related changes influence aortic disease severity in otherwise protected female MFS mice and patients. There may be a role for estrogen in the female sex protective effect.
Machine-learning phenotypic classification of bicuspid aortopathy.
Wojnarski, Charles M; Roselli, Eric E; Idrees, Jay J; Zhu, Yuanjia; Carnes, Theresa A; Lowry, Ashley M; Collier, Patrick H; Griffin, Brian; Ehrlinger, John; Blackstone, Eugene H; Svensson, Lars G; Lytle, Bruce W
2018-02-01
Bicuspid aortic valves (BAV) are associated with incompletely characterized aortopathy. Our objectives were to identify distinct patterns of aortopathy using machine-learning methods and characterize their association with valve morphology and patient characteristics. We analyzed preoperative 3-dimensional computed tomography reconstructions for 656 patients with BAV undergoing ascending aorta surgery between January 2002 and January 2014. Unsupervised partitioning around medoids was used to cluster aortic dimensions. Group differences were identified using polytomous random forest analysis. Three distinct aneurysm phenotypes were identified: root (n = 83; 13%), with predominant dilatation at sinuses of Valsalva; ascending (n = 364; 55%), with supracoronary enlargement rarely extending past the brachiocephalic artery; and arch (n = 209; 32%), with aortic arch dilatation. The arch phenotype had the greatest association with right-noncoronary cusp fusion: 29%, versus 13% for ascending and 15% for root phenotypes (P < .0001). Severe valve regurgitation was most prevalent in root phenotype (57%), followed by ascending (34%) and arch phenotypes (25%; P < .0001). Aortic stenosis was most prevalent in arch phenotype (62%), followed by ascending (50%) and root phenotypes (28%; P < .0001). Patient age increased as the extent of aneurysm became more distal (root, 49 years; ascending, 53 years; arch, 57 years; P < .0001), and root phenotype was associated with greater male predominance compared with ascending and arch phenotypes (94%, 76%, and 70%, respectively; P < .0001). Phenotypes were visually recognizable with 94% accuracy. Three distinct phenotypes of bicuspid valve-associated aortopathy were identified using machine-learning methodology. Patient characteristics and valvular dysfunction vary by phenotype, suggesting that the location of aortic pathology may be related to the underlying pathophysiology of this disease. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Seiffert, Moritz; Diemert, Patrick; Koschyk, Dietmar; Schirmer, Johannes; Conradi, Lenard; Schnabel, Renate; Blankenberg, Stefan; Reichenspurner, Hermann; Baldus, Stephan; Treede, Hendrik
2013-06-01
This study sought to report on the feasibility and early results of transcatheter aortic valve implantation employing a second-generation device in a series of patients with pure aortic regurgitation. Efficacy and safety of transcatheter aortic valve implantation in patients with calcific aortic stenosis and high surgical risk has been demonstrated. However, experience with implantation for severe noncalcified aortic regurgitation has been limited due to increased risk for valve dislocation or annular rupture. Five patients (mean age: 66.6 ± 7 years) underwent transapical implantation of a JenaValve (JenaValve Technology GmbH, Munich, Germany) transcatheter heart valve for moderate to severe, noncalcified aortic regurgitation. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team (logistic EuroSCORE [European System for Cardiac Operative Risk Evaluation] range 3.1% to 38.9%). Procedural and acute clinical outcomes were analyzed. Implantation was successful in all cases without relevant remaining aortic regurgitation or signs of stenosis in any of the patients. No major device- or procedure-related adverse events occurred and all 5 patients were alive with improved exercise tolerance at 3-month follow-up. Noncalcified aortic regurgitation continues to be a challenging pathology for transcatheter aortic valve implantation due to the risk for insufficient anchoring of the valve stent within the aortic annulus. This report provides first evidence that the JenaValve prosthesis may be a reasonable option in these specific patients due to its unique stent design, clipping the native aortic valve leaflets, and offering promising early results. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Wang, Yan-Li; Wang, Qing-Ling; Wang, Liang; Wu, Ying-Biao; Wang, Zhi-Bin; Cameron, James; Liang, Yu-Lu
2013-02-01
The associations between the aortic dimensions (of the aortic sinus, aortic annulus and aortic arch) and physiological variables have not been established in the Chinese population. The present study examined the associations among physiological variables to determine the aortic root and arch dimensions echocardiographically. The diameters of the aortic sinus, annulus and arch were measured in 1,010 subjects via 2-D echocardiography with a 3.5-MHz transducer in a trans-thoracic position. The images of the aortic sinus and aortic annulus were obtained from a standard parasternal long-axis view. The maximum diameter of the valve orifice was measured at the end of systole. The aortic arch dimension was visualized in the long-axis using a suprasternal notch window and the maximum transverse diameter was measured. Epidata 3.0, Excel 2007 and SPSS version 17.0 were used to collect and analyze the data. A total of 1,010 subjects were enrolled. The mean age was 55.0±17.0 years (range of 18 to 90 years). The body surface area (BSA) was the best predictor of all the studied physiological variables and may be used to predict aortic sinus, annulus and arch dimensions independently (r=0.54, 0.37 and 0.39, respectively). Gender, blood pressure, age and BSA are significant predictors of the aortic dimensions. Of these, BSA was the best predictor.
Risks and Challenges of Surgery for Aortic Prosthetic Valve Endocarditis.
Grubitzsch, Herko; Tarar, Waharat; Claus, Benjamin; Gabbieri, Davide; Falk, Volkmar; Christ, Torsten
2018-03-01
Prosthetic valve endocarditis is the most severe form of infective endocarditis. This study assessed the risks and challenges of surgery for aortic prosthetic valve endocarditis. In total, 116 consecutive patients (98 males, age 65.2±12.7years), who underwent redo-surgery for active aortic prosthetic valve endocarditis between 2000 and 2014, were reviewed. Cox regression analysis was used to identify factors for aortic root destructions as well as for morbidity and mortality. Median follow-up was 3.8 years (0-13.9 years). Aortic root destructions (42 limited and 29 multiple lesions) were associated with early prosthetic valve endocarditis and delayed diagnosis (≥14 d), but not with mortality. There were 16 (13.8%) early (≤30 d) and 32 (27.6%) late (>30 days) deaths. Survival at 1, 5, and 10 years was 72±4.3%, 56±5.4%, and 46±6.4%, respectively. The cumulative incidence of death, reinfection, and reoperation was 19.0% at 30days and 36.2% at 1year. Delayed diagnosis, concomitant procedures, and EuroSCORE II >20% were predictors for early mortality and need for mechanical circulatory support, age >70years, and critical preoperative state were predictors for late mortality. In their absence, survival at 10 years was 70±8.4%. Reinfections and reoperations occurred more frequently if ≥1 risk factor for endocarditis and aortic root destructions were present. At 10 years, freedom from reinfection and reoperation was 89±4.2% and 91±4.0%. The risks of death, reinfection, and reoperation are significant within the first year after surgery for aortic prosthetic valve endocarditis. Early diagnosis and aortic root destructions are the most important challenges, but advanced age, critical preoperative state, and the need for mechanical circulatory support determine long-term survival. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Mortality characteristics of aortic root surgery in North America†
Caceres, Manuel; Ma, Yicheng; Rankin, J. Scott; Saha-Chaudhuri, Paramita; Englum, Brian R.; Gammie, James S.; Suri, Rakesh M.; Thourani, Vinod H.; Esmailian, Fardad; Czer, Lawrence S.; Puskas, John D.; Svensson, Lars G.
2014-01-01
OBJECTIVES Aortic root surgery is transitioning to aortic valve sparing (AVS), but little is known about the relative early outcomes of AVS versus composite graft-valve replacement (CVR). This study assessed mortality differences for AVS versus CVR to guide future practice decisions. METHODS From January 2000 to June 2011, 31 747 patients had aortic root replacement with AVS (n = 3585; 11%) or CVR (n = 28 162; 89%). The cohort of Overall patients was divided into two subgroups: high-risk patients (n = 20 356; 6% AVS) having age >75 years, endocarditis, aortic stenosis, dialysis, multiple valves, reoperation or emergency/salvage status, and the remaining low-risk patients (n = 11 388; 21% AVS). Using logistic regression analysis, outcomes were presented as unadjusted operative mortality (UOM), risk-adjusted operative mortality (AOM) and adjusted odds ratio (AOR) for mortality. RESULTS Baseline characteristics for the Overall group (AVS versus CVR) were: mean age (52 vs 57 years), endocarditis (1 vs 11%), aortic stenosis (4 vs 36%), dialysis (1 vs 2%), multiple valves (7 vs 10%), reoperation (6 vs 17%) and emergency status (14 vs 12%) (all P < 0.0001). In high- and low-risk groups, baseline differences narrowed, and lower mortality was generally observed with AVS: (AVS versus CVR) UOM group Overall (4.5 vs 8.9%)*, group High-risk (10.5 vs 11.7%), group Low-risk (1.4 vs 3.1%)*; AOM group Overall (6.2 vs 8.6%), group High-risk (10.1 vs 11.7%), group Low-risk (2.2 vs 2.8%); AOR group Overall (0.59)*, group High-risk (0.62)*, group Low-risk (0.69). *P < 0.05. CONCLUSIONS Relative risk-adjusted mortality seemed comparable with AVS versus CVR in low- and high-risk subgroups. These data support judicious expansion of aortic valve repair in patients having aortic root replacement. PMID:24639452
The influence of emotional stress on Doppler-derived aortic peak velocity in boxer dogs.
Pradelli, D; Quintavalla, C; Crosta, M C; Mazzoni, L; Oliveira, P; Scotti, L; Brambilla, P; Bussadori, C
2014-01-01
Subaortic stenosis (SAS) is a common congenital heart disease in Boxers. Doppler-derived aortic peak velocity (AoPV) is a diagnostic criterion for the disease. To investigate the influence of emotional stress during echocardiographic examination on AoPV in normal and SAS-affected Boxers. To evaluate the effects of aortic root diameters on AoPV in normal Boxers. DOGS: Two hundred and fifteen normal and 19 SAS-affected Boxers. The AoPV was recorded at the beginning of echocardiographic examination (T0), and when the emotional stress of the dog was assumed to decrease based on behavioral parameters and heart rate (T1). AoPV0-AoPV1 was calculated. In normal dogs, stroke volume index was calculated at T0 and T1. Aortic root diameters were measured and their relationship with AoPV and AoPV0-AoPV1 was evaluated. In normal dogs, AoPV was higher at T0 (median, 1.95 m/s; range, 1.60-2.50 m/s) than at T1 (median, 1.76 m/s; range, 1.40-2.20 m/s; P < .0001; reduction 9.2%). The stroke volume index at T0 also was greater than at T1 (P < .0001). Weak negative correlations were detected between aortic root size and aortic velocities. In SAS-affected dogs, AoPV0 was higher than AoPV1 (P < .0001; reduction 7.3%). Aortic peak velocity was affected by emotional stress during echocardiographic examination both in SAS-affected and normal Boxers. In normal Boxers, aortic root size weakly affected AoPVs, but did not affect AoPV0-AoPV1. Stroke volume seems to play a major role in stress-related AoPV increases in normal Boxers. Emotional stress should be taken into account when screening for SAS in the Boxer breed. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Mortality characteristics of aortic root surgery in North America.
Caceres, Manuel; Ma, Yicheng; Rankin, J Scott; Saha-Chaudhuri, Paramita; Englum, Brian R; Gammie, James S; Suri, Rakesh M; Thourani, Vinod H; Esmailian, Fardad; Czer, Lawrence S; Puskas, John D; Svensson, Lars G
2014-11-01
Aortic root surgery is transitioning to aortic valve sparing (AVS), but little is known about the relative early outcomes of AVS versus composite graft-valve replacement (CVR). This study assessed mortality differences for AVS versus CVR to guide future practice decisions. From January 2000 to June 2011, 31 747 patients had aortic root replacement with AVS (n = 3585; 11%) or CVR (n = 28 162; 89%). The cohort of Overall patients was divided into two subgroups: high-risk patients (n = 20 356; 6% AVS) having age >75 years, endocarditis, aortic stenosis, dialysis, multiple valves, reoperation or emergency/salvage status, and the remaining low-risk patients (n = 11 388; 21% AVS). Using logistic regression analysis, outcomes were presented as unadjusted operative mortality (UOM), risk-adjusted operative mortality (AOM) and adjusted odds ratio (AOR) for mortality. Baseline characteristics for the Overall group (AVS versus CVR) were: mean age (52 vs 57 years), endocarditis (1 vs 11%), aortic stenosis (4 vs 36%), dialysis (1 vs 2%), multiple valves (7 vs 10%), reoperation (6 vs 17%) and emergency status (14 vs 12%) (all P < 0.0001). In high- and low-risk groups, baseline differences narrowed, and lower mortality was generally observed with AVS: (AVS versus CVR) UOM group Overall (4.5 vs 8.9%)*, group High-risk (10.5 vs 11.7%), group Low-risk (1.4 vs 3.1%)*; AOM group Overall (6.2 vs 8.6%), group High-risk (10.1 vs 11.7%), group Low-risk (2.2 vs 2.8%); AOR group Overall (0.59)*, group High-risk (0.62)*, group Low-risk (0.69). *P < 0.05. Relative risk-adjusted mortality seemed comparable with AVS versus CVR in low- and high-risk subgroups. These data support judicious expansion of aortic valve repair in patients having aortic root replacement. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Tetralogy of Fallot and aortic root dilation: a long-term outlook.
Nagy, Christian D; Alejo, Diane E; Corretti, Mary C; Ravekes, William J; Crosson, Jane E; Spevak, Philip J; Ringel, Richard; Carson, Kathryn A; Khalil, Sara; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A; Traill, Thomas A; Holmes, Kathryn W
2013-04-01
Dilation of the sinus of Valsalva (SoV) has been increasingly observed after repaired tetralogy of Fallot (TOF). We estimate the prevalence of SoV dilation in adults with repaired TOF and analyze possible factors related to aortic disease. Adults with TOF [n = 109, median age 33.2 years (range 18.1 to 69.5)] evaluated at Johns Hopkins Hospital from 2001 to 2009 were reviewed in an observational retrospective cohort study. Median follow-up was 27.3 (range 0.1-48.8) years. SoV dilation was defined as >95 % confidence interval adjusted for age and body surface area (z-score > 2). The prevalence of SoV dilation was 51 % compared with that of a normal population with a mean z-score of 2.03. Maximal aortic diameters were ≥ 4 cm in 39 % (42 of 109), ≥ 4.5 cm in 21 % (23 of 109), ≥ 5 cm in 8 % (9 of 109), and ≥ 5.5 cm in 2 % (2 of 109). There was no aortic dissection or death due contributable to aortic disease. Aortic valve replacement was performed in 1.8 % and aortic root or ascending aorta (AA) replacement surgery in 2.8 % of patients. By multivariate logistic regression analysis, aortic regurgitation (AR) [odds ratio (OR) = 3.09, p = 0.005], residual ventricular septal defect (VSD) (OR = 4.14, p < 0.02), and TOF with pulmonary atresia (TOF/PA) (OR = 6.75, p = 0.03) were associated with increased odds of dilated aortic root. SoV dilation after TOF repair is common and persists with aging. AR, residual VSD, and TOF/PA are associated with increased odds of dilation. AA evaluation beyond the SoV is important. Indexed values are imperative to avoid bias on the basis of age and body surface area.
A Dental Prosthesis from the Early Modern Age in Tuscany (Italy).
Minozzi, Simona; Panetta, Daniele; De Sanctis, Massimo; Giuffra, Valentina
2017-04-01
During archaeological excavation, carried out in the S. Francesco Monastery at Lucca (Tuscany, Italy), a golden dental appliance was discovered. The prosthesis was found, together with commingled human remains, in the collective tomb of the aristocratic family of the Guinigi, a powerful family who governed Lucca from 1392 until 1429. The exact archaeological dating of the prosthesis was not possible, but some elements suggest a dating to the beginning of the 17th century. Aim of the paper is to study and describe the dental appliance trough a multidisciplinary approach. Macroscopical and micro-CT examinations were performed to investigate the technics used for the realization of the dental prosthesis. SEM analysis was performed to study alloy composition of the metallic fixing lamina and microstructure of the deposits on the dental surface. The dental prosthesis consists in five mandibular teeth: three central incisors and two lateral canines linked together by a golden band inserted into the dental roots to replace the anterior arch of the jaw. Micro-CT scan revealed the presence of two small golden pins inserted into each tooth crossing the root and fixing the teeth to the internal gold band. SEM examination of the lamina indicated a homogeneous composition, with average contents of 73 wt% gold, 15.6 wt% Ag, and 11.4 wt% Cu. Apposition of dental calculus on the teeth indicated that the prosthesis had been worn for a long period. This dental prosthesis provides a unique finding of technologically advanced dentistry in this period. In fact, during the Early Modern Age, some authors described gold band technology for the replacement of missing teeth; nevertheless, no direct evidences of these devices have been brought to light up so far. © 2016 Wiley Periodicals, Inc.
Feature-based US to CT registration of the aortic root
NASA Astrophysics Data System (ADS)
Lang, Pencilla; Chen, Elvis C. S.; Guiraudon, Gerard M.; Jones, Doug L.; Bainbridge, Daniel; Chu, Michael W.; Drangova, Maria; Hata, Noby; Jain, Ameet; Peters, Terry M.
2011-03-01
A feature-based registration was developed to align biplane and tracked ultrasound images of the aortic root with a preoperative CT volume. In transcatheter aortic valve replacement, a prosthetic valve is inserted into the aortic annulus via a catheter. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to significant morbidity and mortality. Registration of pre-operative CT to transesophageal ultrasound and fluoroscopy images is a major step towards providing augmented image guidance for this procedure. The proposed registration approach uses an iterative closest point algorithm to register a surface mesh generated from CT to 3D US points reconstructed from a single biplane US acquisition, or multiple tracked US images. The use of a single simultaneous acquisition biplane image eliminates reconstruction error introduced by cardiac gating and TEE probe tracking, creating potential for real-time intra-operative registration. A simple initialization procedure is used to minimize changes to operating room workflow. The algorithm is tested on images acquired from excised porcine hearts. Results demonstrate a clinically acceptable accuracy of 2.6mm and 5mm for tracked US to CT and biplane US to CT registration respectively.
Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.
Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F
1983-09-01
Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.
Nezafati, Pouya; Nezafati, Mohammad Hassan; Hoseinikhah, Hamid
2015-01-01
Introduction. Unruptured sinus of valsalva aneurysm (SVA) is a rare congenital anomaly, particularly, when it coexists with a ventricular septal defect (VSD) and aortic regurgitation due to the prolapse of the elongated aortic cusp into the VSD. In this report, we present the case of a 19-year-old young man with VSD challenging in spite of dyspnea and lower limb edema. Presentation of Case. Its diagnosis was made on the basis of transthoracic echocardiography results. Surgical management consisted of replacing the SVA with mechanical valve prosthesis. A Gore-Tex patch repaired the VSD. Discussion. In the follow-up periods, clinical and echocardiographic tests showed that the patient was in excellent status. Conclusion. SVA requires a surgical procedure due to its high risk of mortality in unoperated patients and a good safety of surgery. PMID:26236342
Perceval S aortic valve implantation in an achondroplastic Dwarf
Baikoussis, Nikolaos G.; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis
2016-01-01
Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography. PMID:26750695
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-01-01
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable. PMID:24510692
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-02-07
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.
Sherif, Hisham M.F.
2014-01-01
An extensive search of the medical literature examining the development of the thoracic aortic tree reveals that the thoracic aorta does not develop as one unit or in one stage: the oldest part of the thoracic aorta is the descending aorta with the aortic arch being the second oldest, developing under influence from the neural crest cell. Following in chronological order are the proximal ascending aorta and aortic root, which develop from a conotruncal origin. Different areas of the thoracic aorta develop under the influence of different gene sets. These parts develop from different cell lineages: the aortic root (the conotruncus), developing from the mesoderm; the ascending aorta and aortic arch, developing from the neural crest cells; and the descending aorta from the mesoderm. Findings illustrate that the thoracic aorta is not a single entity, in developmental terms. It develops from three or four distinct areas, at different stages of embryonic life, and under different sets of genes and signaling pathways. Genetically triggered thoracic aortic aneurysms are not a monolithic group but rather share a multi-genetic origin. Identification of therapeutic targets should be based on the predilection of certain genes to cause aneurysmal disease in specific aortic segments. PMID:26798739
Aortic assessment of bicuspid aortic valve patients and their first-degree relatives.
Straneo, Pablo; Parma, Gabriel; Lluberas, Natalia; Marichal, Alvaro; Soca, Gerardo; Cura, Leandro; Paganini, Juan J; Brusich, Daniel; Florio, Lucia; Dayan, Victor
2017-03-01
Background Bicuspid aortic valve patients have an increased risk of aortic dilatation. A deficit of nitric oxide synthase has been proposed as the causative factor. No correlation between flow-mediated dilation and aortic diameter has been performed in patients with bicuspid aortic valves and normal aortic diameters. Being a hereditary disease, we compared echocardiographic features and endothelial function in these patients and their first-degree relatives. Methods Comprehensive physical examinations, routine laboratory tests, transthoracic echocardiography, and measurements of endothelium-dependent and non-dependent flow-mediated vasodilatation were performed in 18 bicuspid aortic valve patients (14 type 1 and 4 type 2) and 19 of their first-degree relatives. Results The first-degree relatives were younger (36.7 ± 18.8 vs. 50.5 ± 13.9 years, p = 0.019) with higher ejection fractions (64.6% ± 1.7% vs. 58.4% ± 9.5%, p = 0.015). Aortic diameters indexed to body surface area were similar in both groups, the except the tubular aorta which was larger in bicuspid aortic valve patients (19.3 ± 2.7 vs. 17.4 ± 2.2 mm·m -2 , p = 0.033). Flow-dependent vasodilation was similar in both groups. A significant inverse correlation was found between non-flow-dependent vasodilation and aortic root diameter in patients with bicuspid aortic valve ( R = -0.57, p = 0.05). Conclusions Bicuspid aortic valve patients without aortopathy have larger ascending aortic diameters than their first-degree relatives. Endothelial function is similar in both groups, and there is no correlation with ascending aorta diameter. Nonetheless, an inverse correlation exists between non-endothelial-dependent dilation and aortic root diameter in bicuspid aortic valve patients.
Genetic abnormalities in bicuspid aortic valve root phenotype: preliminary results.
Girdauskas, Evaldas; Geist, Lisa; Disha, Kushtrim; Kazakbaev, Iliaz; Groß, Tatiana; Schulz, Solveig; Ungelenk, Martin; Kuntze, Thomas; Reichenspurner, Hermann; Kurth, Ingo
2017-07-01
Genetic defects associated with bicuspid aortopathy have been infrequently analysed. Our goal was to examine the prevalence of rare genetic variants in patients with a bicuspid aortic valve (BAV) with a root phenotype using next-generation sequencing technology. We investigated a total of 124 patients with BAV with a root dilatation phenotype who underwent aortic valve ± proximal aortic surgery at a single institution (BAV database, n = 812) during a 20-year period (1995-2015). Cross-sectional follow-up revealed 63 (51%) patients who were still alive and willing to participate. Systematic follow-up visits were scheduled from March to December 2015 and included aortic imaging as well as peripheral blood sampling for genetic testing. Next-generation sequencing libraries were prepared using a custom-made HaloPlex HS gene panel and included 20 candidate genes known to be associated with aortopathy and BAV. The primary end-point was the prevalence of genetic defects in our study cohort. A total of 63 patients (mean age 46 ± 10 years, 92% men) with BAV root phenotype and mean post-aortic valve replacement follow-up of 10.3 ± 4.9 years were included. Our genetic analysis yielded a wide spectrum of rare, potentially or likely pathogenic variants in 19 (30%) patients, with NOTCH1 variants being the most common ( n = 6). Moreover, deleterious variants were revealed in AXIN1 ( n = 3), NOS3 ( n = 3), ELN ( n = 2), FBN1 ( n = 2) , FN1 ( n = 2) and rarely in other candidate genes. Our preliminary study demonstrates a high prevalence and a wide spectrum of rare genetic variants in patients with the BAV root phenotype, indicative of the potentially congenital origin of associated aortopathy in this specific BAV cohort. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Soumoulou, Juan Bautista; Cianciulli, Tomás Francisco; Zappi, Andrea; Cozzarin, Alberto; Saccheri, María Cristina; Lax, Jorge Alberto; Guidoin, Robert; Zhang, Ze
2015-01-01
Pannus formation is a rare complication and occurs almost exclusively in mechanical prosthetic valves. It consists of fibrous tissue that covers the surface of the prosthesis either concentrically or eccentrically, resulting in valve dysfunction. The pathophysiology seems to be associated to a chronic inflammatory process that explains the late and insidious clinical presentation. This diagnosis should be considered in patients with high transvalvular gradients on transthoracic echo, and workup should be completed with fluoroscopy and transesophageal echocardiography. Treatment is always surgical and recurrence is rare. We present a case of pannus formation in a prosthetic aortic valve and a review of the literature regarding this disorder. PMID:25914791
Soumoulou, Juan Bautista; Cianciulli, Tomás Francisco; Zappi, Andrea; Cozzarin, Alberto; Saccheri, María Cristina; Lax, Jorge Alberto; Guidoin, Robert; Zhang, Ze
2015-04-26
Pannus formation is a rare complication and occurs almost exclusively in mechanical prosthetic valves. It consists of fibrous tissue that covers the surface of the prosthesis either concentrically or eccentrically, resulting in valve dysfunction. The pathophysiology seems to be associated to a chronic inflammatory process that explains the late and insidious clinical presentation. This diagnosis should be considered in patients with high transvalvular gradients on transthoracic echo, and workup should be completed with fluoroscopy and transesophageal echocardiography. Treatment is always surgical and recurrence is rare. We present a case of pannus formation in a prosthetic aortic valve and a review of the literature regarding this disorder.
Chang, Jen-Ping; Kao, Chiung-Lun; Hsieh, Ming-Jang
2002-06-01
Aortic root replacement with pulmonary autograft (Ross procedure) is a valuable technique. However, the best material for right ventricular outflow tract reconstruction remains controversial. We report on the experience with use of an aortic autograft with reimplantation of the diseased aortic valve for right ventricular outflow tract reconstruction in 3 patients with satisfactory result.
Anselmino, Matteo; Torri, Federica; Ferraris, Federico; Calò, Leonardo; Castagno, Davide; Gili, Sebastiano; Rovera, Chiara; Giustetto, Carla; Gaita, Fiorenzo
2017-07-01
Atrial fibrillation transcatheter ablation (TCA) is, within available atrial fibrillation rhythm control strategies, one of the most effective. To potentially improve ablation outcome in case of recurrent atrial fibrillation after a first procedure or in presence of structural myocardial disease, isolation of the pulmonary veins may be associated with extensive lesions within the left atrium. To avoid rare, but potentially life-threatening, complications, thorough knowledge and assessment of left atrium anatomy and its relation to structures in close proximity are, therefore, mandatory. Aim of the present study is to describe, by cardiac computed tomography, the anatomic relationship between aortic root, left coronary artery and left atrium in patients undergoing atrial fibrillation TCA. The cardiac computed tomography scan of 21 patients affected by atrial fibrillation was elaborated to segment left atrium, aortic root and left coronary artery from the surrounding structures and the following distances measured: left atrium and aortic root; left atrium roof and aortic root; left main coronary artery and left atrium; circumflex artery and left atrium appendage; and circumflex artery and mitral valve annulus. Above all, the median distance between left atrium and aortic root (1.9, 1.5-2.1 mm), and between circumflex artery and left atrium appendage ostium (3.0, 2.1-3.4 mm) were minimal (≤3 mm). None of measured distances significantly varied between patients presenting paroxysmal versus persistent atrial fibrillation. The anatomic relationship between left atrium and coronary arteries is extremely relevant when performing atrial fibrillation TCA by extensive lesions. Therefore, at least in the latter case, preablation imaging should be recommended to avoid rare, but potentially life-threatening, complications with the aim of an as well tolerated as possible procedure.
Svensson, Lars G; Pillai, Saila T; Rajeswaran, Jeevanantham; Desai, Milind Y; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Thamilarasan, Maran; Roselli, Eric E; Pettersson, Gösta B; Gillinov, A Marc; Navia, Jose L; Smedira, Nicholas G; Sabik, Joseph F; Lytle, Bruce W; Blackstone, Eugene H
2016-03-01
To evaluate long-term results of aortic root procedures combined with ascending aorta replacement for aneurysms, using 4 surgical strategies. From January 1995 to January 2011, 957 patients underwent 1 of 4 aortic root procedures: valve preservation (remodeling or modified reimplantation, n = 261); composite biologic graft (n = 297); composite mechanical graft (n = 156); or allograft root (n = 243). Seven deaths occurred (0.73%), none after valve-preserving procedures, and 13 strokes (1.4%). Composite grafts exhibited higher gradients than allografts or valve preservation, but the latter 2 exhibited more aortic regurgitation (2.7% biologic and 0% mechanical composite grafts vs 24% valve-preserving and 19% allografts at 10 years). Within 2 to 5 years, valve preservation exhibited the least left ventricular hypertrophy, allograft replacement the greatest; however, valve preservation had the highest early risk of reoperation, allograft replacement the lowest. Patients receiving allografts had the highest risk of late reoperation (P < .05), and those receiving composite mechanical grafts and valve preservation had the lowest. Composite bioprosthesis patients had the highest risk of late death (57% at 15 years vs 14%-26% for the remaining procedures, P < .0001), because they were substantially older and had more comorbidities (P < .0001). These 4 aortic root procedures, combined with ascending aorta replacement, provide excellent survival and good durability. Valve-preserving and allograft procedures have the lowest gradients and best ventricular remodeling, but they have more late regurgitation, and likely, less risk of valve-related complications, such as bleeding, hemorrhage, and endocarditis. Despite the early risk of reoperation, we recommend valve-preserving procedures for young patients when possible. Composite bioprostheses are preferable for the elderly. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Sorajja, Paul; Kodali, Susheel; Reardon, Michael J; Szeto, Wilson Y; Chetcuti, Stanley J; Hermiller, James; Chenoweth, Sharla; Adams, David H; Popma, Jeffrey J
2017-10-23
The authors sought to compare the outcomes of commercial transcatheter aortic valve replacement (TAVR) with the repositionable Evolut R platform to those observed with the CoreValve device in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapy (TVT) Registry. TAVR continues to evolve, with rapid adoption of iterative changes for commercial practice. Insight into the outcomes of this adoption is needed. Patients in the TVT Registry who had TAVR using a 23-, 26-, or 29-mm self-expanding prosthesis were enrolled. Site-reported events for procedural, in-hospital, and 30-day outcomes were examined. Between January 2014 and April 2016, 9,616 patients underwent TAVR with a self-expanding prosthesis with data entered in the TVT Registry. Compared with patients treated with CoreValve TAVR, those who received Evolut R TAVR had a lower STS-PROM score (8.0 ± 5.4% vs. 8.7 ± 5.3%; p < 0.001), more iliofemoral access (91.6% vs. 89.2%; p < 0.001), and more frequently had conscious sedation (27.4% vs. 12.7%; p < 0.001). With Evolut R TAVR, there was less need for a second prosthesis (2.2% vs. 4.5%; p < 0.001), less device migration (0.2% vs. 0.6%; p = 0.01), a lower incidence of moderate/severe paravalvular regurgitation (post-procedure, 4.4% vs. 6.2%; p < 0.001), and shorter median hospital stay (4.0 vs. 5.0 days; p < 0.001). Patients treated with Evolut R TAVR had greater device success (96.3% vs. 94.9%; p = 0.001). At 30 days, Evolut R patients had both lower mortality (3.7% vs. 5.3%; p < 0.001) and less need for a pacemaker (18.3% vs. 20.1%; p = 0.03). Commercial adoption of the Evolut R platform is associated with significant improvements in acute outcomes for patients undergoing TAVR for aortic stenosis. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Akodad, Mariama; Lattuca, Benoit; Agullo, Audrey; Macia, Jean-Christophe; Gandet, Thomas; Marin, Grégory; Iemmi, Anaïs; Vernhet, Hélène; Schmutz, Laurent; Nagot, Nicolas; Albat, Bernard; Cayla, Guillaume; Leclercq, Florence
2018-05-15
Calcium score (CS) is a well-known prognostic factor after transcatheter aortic valve implantation (TAVI) performed with first generation prosthesis but few data are available concerning new generation valves. The aim of this study was to evaluate if CS remains a prognostic factor after Sapien 3 and Evolut R valves implantation. Agatston CS was evaluated on multislice computed tomography before TAVI in 346 patients implanted with Sapien XT (n = 61), CoreValve (n = 57) devices, (group 1, n = 118), and with new generation Sapien 3 (n = 147), Evolut R (n = 81) prosthesis, (group 2, n = 228). Major adverse cardiovascular events and aortic regurgitation (AR) were evaluated at 1 month. The 2 groups were similar at baseline except for logistic Euroscore (20.1% in group 1 vs 15.0 % in group 2; p = 0.001), chronic renal failure (44.1% vs 37.2% respectively, p = 0.007) and preprocedural CS (4,092 ± 2,176 vs 3,682 ± 2,109 respectively, p = 0.022). In group 1, 28 patients (23.7%) had adverse clinical events vs 21 (9.2%) in group 2 (p <0.01). In multivariate analysis, a higher CS was predictive of adverse events in group 1 (5,785 ± 3,285 vs 3,565 ± 1,331 p <0.0001) but not in group 2 (p = 0.28). A higher CS was associated with AR in group 1 (6,234 ± 2711 vs 3,429 ± 1,505; p <0.001) and in patients implanted with an Evolut R device from group 2 (4,085 ± 3,645 vs 2,551 ± 1,356; p = 0.01). In conclusion, CS appears as an important prognostic factor of major events after TAVI with first generation valves but not with new generation devices. CS remains associated with AR only with new generation self-expandable Evolut R devices. Copyright © 2018 Elsevier Inc. All rights reserved.
Wang, H J; Xiao, Z Y; Gu, G R; Xue, Y; Shao, M; Deng, Z; Tao, Z G; Yao, C L; Tong, C Y
2017-11-24
Objective: To investigate the value of bedside echocardiography in diagnosis and risk assessment of in-hospital death of patients with Stanford type A aortic dissection. Methods: The clinical data of 229 patients with Stanford type A aortic dissection diagnosed by CT angiography in Zhongshan Hospital affiliated to Fudan University between January 2009 and January 2016 were retrospectively analyzed. The patients were divided into survival group(191 cases)and non-survival group(38 cases)according to presence or absence of in-hospital death. The bedside echocardiography features were analyzed, and influence factors of in-hospital death were determined by multivariate logistic regression analysis. Results: (1) Compared with the survival group, the non-survival group had lower surgery rate (60.52%(23/38) vs. 85.34%(163/191), P <0.01). Age, gender and Debakey classification were similar between survival group and death group (all P >0.05). (2) The bedside echocardiography results showed that prevalence of aortic valve involvement(65.79%(25/38) vs.34.03%(65/191), P <0.01) and severe aortic regurgitation (44.74%(17/38) vs. 14.14%(27/191), P <0.01) were significantly higher in non-survival group than in survival group. The non-survival group had larger aortic root diameter than the survival group ((55.5±6.4)mm vs. (42.3±7.8)mm, P <0.01). There were no significant differences in pericardial effusion, expansion of aortic sinus, and left ventricular ejection fraction between survival group and non-survival group (all P >0.05). (3) The multivariate logistic regression analysis showed that aortic valve involvement( OR =3.275, 95% CI 1.290-8.313, P <0.05), aortic root diameter( OR =1.202, 95% CI 1.134-1.275, P <0.01), and surgery ( OR =0.224, 95% CI 0.079-0.629, P <0.01) were independent risk factors for in-hospital death in patients with Stanford type A aortic dissection. Conclusions: Bedside echocardiography has significant diagnostic value for Stanford type A aortic dissection. Aortic valve involvement, enlargement of aortic root diameter and without surgery are independent risk factors for patients with Stanford type A aortic dissection.
Impact of pregnancy on autograft dilatation and aortic valve function following the Ross procedure.
Carvajal, Horacio G; Lindley, Kathryn J; Shah, Trupti; Brar, Anoop K; Barger, Philip M; Billadello, Joseph J; Eghtesady, Pirooz
2018-03-01
The effects of pregnancy on autograft dilatation and neoaortic valve function in patients with a Ross procedure have not been studied. We sought to evaluate the effect of pregnancy on autograft dilatation and valve function in these patients with the goal of determining whether pregnancy is safe after the Ross procedure. A retrospective chart review of female patients who underwent a Ross procedure was conducted. Medical records for 51 patients were reviewed. Among the 33 patients who met inclusion criteria, 11 became pregnant after surgery and 22 did not. Echocardiographic reports were used to record aortic root diameter and aortic insufficiency before, during, and after pregnancy. Patient's charts were reviewed for reinterventions and complications. Primary endpoints included reinterventions, aortic root dilation of ≥5 cm, aortic insufficiency degree ≥ moderate, and death. There were 18 pregnancies carried beyond 20 weeks in 11 patients. There was no significant difference in aortic root diameter between nulliparous patients and parous patients prior to their first pregnancy (3.53 ± 0.44 vs 3.57 ± 0.69 cm, P = .74). There was no significant change in aortic root diameter after first pregnancy (3.7 ± 0.4 cm, P = .056) although there was significant dilatation after the second (4.3 ± 0.7 cm, P = .009) and third (4.5 ± 0.7 cm, P = .009) pregnancies. Freedom from combined endpoints was significantly higher for patients in the pregnancy group than those in the nonpregnancy group (P = .002). Pregnancy was not associated with significantly increased adverse events in patients following the Ross procedure. Special care should be taken after the first pregnancy, as multiparity may lead to increased neoaortic dilatation. © 2017 Wiley Periodicals, Inc.
Volumetric velocimetry downstream of a percutaneous heart valve
NASA Astrophysics Data System (ADS)
Raghav, Vrishank; Clifford, Christopher; Midha, Prem; Okafor, Ikechukwu; Thurow, Brian; Yoganathan, Ajit; Auburn University Collaboration; Georgia Institute of Technology Collaboration
2017-11-01
Transcatheter aortic valve replacement has emerged as a safe and effective treatment for severe, symptomatic aortic stenosis in intermediate or greater surgical risk patients. However, despite excellent short-term outcomes, improved imaging and awareness has led to the identification of leaflet thrombosis on the aortic side of the prosthesis. Upon implantation, the transcatheter heart valve (THV) becomes enclosed in the native aortic valve leaflet tissue dividing the native sinus into two regions - a smaller anatomical sinus and a neo-sinus. To understand the causes for thrombosis, plenoptic Particle Image Velocimetry (PIV) is used to investigate the pulsatile three-dimensional flow in the sinus and neo-sinus region of the THV. Experiments are conducted on both a real and a transparent THV model in a pulsatile flow loop capable of replicating physiological hemodynamics. Comparisons with planar PIV results demonstrate the feasibility of using Plenoptic PIV to study heart valve fluid dynamics. Large three-dimensional regions of low velocity magnitude and low viscous shear stress were observed near the heart valve which could increase particle residence time potentially leading to formation of clots the THV leaflet.
Pak, Sang-Woo; Uriel, Nir; Takayama, Hiroo; Cappleman, Sarah; Song, Robert; Colombo, Paolo C; Charles, Sandy; Mancini, Donna; Gillam, Linda; Naka, Yoshifumi; Jorde, Ulrich P
2010-10-01
Left ventricular assist devices (LVADs) are increasingly used as long-term therapy for end-stage heart failure patients. We compared the prevalence of aortic insufficiency (AI) after HeartMate II (HMII) vs HeartMate XVE (HMI) support and assessed the role of aortic root diameter and aortic valve opening in the development of AI. Pre-operative and post-operative echocardiograms of 93 HMI and 73 HMII patients who received implants at our center between January 2004 and September 2009 were retrospectively reviewed. After excluding patients with prior or concurrent surgical manipulation of the aortic valve, with baseline AI, or without baseline echoes, 67 HMI and 63 HMII patients were studied. AI was deemed significant if mild to moderate or greater. Pathology reports were reviewed for 77 patients who underwent heart transplant. AI developed in 4 of 67 HMI (6.0%) and in 9 of 63 HMII patients (14.3%). The median times to AI development were 48 days for HMI patients and 90 days for HMII patients. For patients who remained on device support at 6 and 12 months, freedom from AI was 94.5% and 88.9% in HMI patients and 83.6% and 75.2% in HMII patients (log rank p = 0.194). Aortic root diameters, as determined by echocardiography for the patients with AI, trended to be larger at baseline (3.43 ± 0.43 vs 3.15 ± 0.40; p = 0.067) and follow-up (3.58 ± 0.54 vs 3.29 ± 0.50; p = 0.130) compared with those who did not have AI. Aortic root circumferences were assessed directly by a pathologist in those patients who underwent transplant and were significantly larger in HMII patients who had developed AI compared with those patients who did not (8.44 ± 0.89 vs 7.36 ± 1.02 cm; p = 0.034). Lastly, AI was more common in patients whose aortic valve did not open (11 of 26 vs 1 of 14; p = 0.03). Aortic insufficiency occurs frequently in patients who receive continuous-flow support with a HMII LVAD, and may be associated with aortic root diameter enlargement and aortic valve opening. These findings warrant a more thorough preoperative patient evaluation and additional studies to investigate the factors, that may be associated with AI development. Copyright © 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Current surgical results of acute type A aortic dissection in Japan.
Okita, Yutaka
2016-07-01
Current surgical results of acute type A aortic dissection in Japan are presented. According to the annual survey by the Japanese Association of Thoracic Surgery, 4,444 patients with acute type A aortic dissection underwent surgical procedures and the overall hospital mortality was 9.1% in 2013. The prevalence of aortic root replacement with a valve sparing technique, total arch replacement (TAR), and frozen stent graft are presented and strategies for thrombosed dissection or organ malperfusion syndrome secondary to acute aortic dissection are discussed.
Echocardiographic measurements of the aorta in normal children and young adults.
Kaldararova, M; Balazova, E; Tittel, P; Stankovicova, I; Brucknerova, I; Masura, J
2007-01-01
To be able to determine aortic valve and ascending aorta pathology, especially aortic root dilatation, it is important to establish normal aortic dimensions. The aim of the study was to measure the dimensions of the aorta in normal healthy children and young adults in Slovakia. 702 healthy subjects, from newborns to 20 years of age, were examined at our institution. The study was carried out prospectively, by a single observer, using digitized two-dimensional (2D), Doppler and M-mode echocardiography. The aorta was measured at 3 sites: 1. aortic valve annulus, 2. sinuses of Valsalva, 3. sinotubular junction. Patients were divided into 28 groups according to their body surface area (BSA)--from 0.15 to 2.0 m2. All data were statistically evaluated (mean value, 5th and 95th percentile for all BSA groups) and regression equations were calculated for each parameter. All 3 measured aortic parameters correlated closely. Measures of correlation (R-squared) for aortic parameters with the square root of BSA were high: 0.89 for aortic valve annulus, 0.86 for sinuses of Valsalva and 0.86 for sinotubular junction (Tab. 3, Fig. 7, Ref 13). Full Text (Free, PDF) www.bmj.sk
Endovascular closure of ascending aortic pseudoaneurysm with a type II Amplatzer vascular plug.
De Boo, Diederick W; Mott, Nigel; Kavnoudias, Helen; Walton, Antony; Lyon, Stuart M
2014-05-01
A 71-year-old man initially presented with an asymptomatic, incidentally detected ascending aortic pseudoaneurysm 25 years following aortic root repair with mechanical aortic valve replacement. This pseudoaneurysm was previously treated with coil embolization but due to coil impaction it reopened 8 years later. Endovascular closure of the pseudoaneurysm was achieved with the off-label use of a type II Amplatzer vascular plug.
Husser, Oliver; Kessler, Thorsten; Burgdorf, Christof; Templin, Christian; Pellegrini, Costanza; Schneider, Simon; Kasel, Albert Markus; Kastrati, Adnan; Schunkert, Heribert; Hengstenberg, Christian
2016-02-01
Transcatheter aortic valve implantation is increasingly used in patients with aortic stenosis. Post-procedural intraventricular conduction abnormalities and permanent pacemaker implantations remain a serious concern. Recently, the Edwards SAPIEN 3 prosthesis has replaced the SAPIEN XT. We sought to determine the incidences of new-onset intraventricular conduction abnormalities and permanent pacemaker implantations by comparing the 2 devices. We analyzed the last consecutive 103 patients undergoing transcatheter aortic valve implantation with SAPIEN XT before SAPIEN 3 was used in the next 105 patients. To analyze permanent pacemaker implantations and new-onset intraventricular conduction abnormalities, patients with these conditions at baseline were excluded. Electrocardiograms were recorded at baseline, after the procedure, and before discharge. SAPIEN 3 was associated with higher device success (100% vs 92%; P=.005) and less paravalvular leakage (0% vs 7%; P<.001). The incidence of permanent pacemaker implantations was 12.6% (23 of 183) with no difference between the 2 groups (SAPIEN 3: 12.5% [12 of 96] vs SAPIEN XT: 12.6% [11 of 87]; P=.99). SAPIEN 3 was associated with a higher rate of new-onset intraventricular conduction abnormalities (49% vs 27%; P=.007) due to a higher rate of fascicular blocks (17% vs 5%; P=.021). There was no statistically significant difference in transient (29% [20 of 69] vs persistent 19% [12 of 64]; P=.168) left bundle branch blocks (28% [19 of 69] vs 17% [11 of 64]; P=.154) when SAPIEN 3 was compared with SAPIEN XT. We found a trend toward a higher rate of new-onset intraventricular conduction abnormalities with SAPIEN 3 compared with SAPIEN XT, although this did not result in a higher permanent pacemaker implantation rate. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Samim, Mariam; van der Worp, Bart; Agostoni, Pierfrancesco; Hendrikse, Jeroen; Budde, Ricardo P J; Nijhoff, Freek; Ramjankhan, Faiz; Doevendans, Pieter A; Stella, Pieter R
2017-02-15
This study aims to evaluate the safety and performance of the new embolic deflection device TriGuard™HDH in patients undergoing TAVR. Transcatheter aortic valve replacement (TAVR) is associated with a high incidence of new cerebral ischemic lesions. The use of an embolic protection device may reduce the frequency of TAVR-related embolic events. This prospective, single arm feasibility pilot study included 14 patients with severe symptomatic aortic stenosis scheduled for TAVR. Cerebral diffusion weighted magnetic resonance imaging (DWI) was planned in all patients one day before and at day 4 (±2) after the procedure. Major adverse cerebral and cardiac events (MACCEs) were recorded for all patients. Primary endpoints of this study were I) device performance success defined as coverage of the aortic arch takeoffs throughout the entire TAVR procedure and II) MACCE occurrence. Secondary endpoints included the number and the volume of new cerebral ischemic lesions on DWI. Thirteen patients underwent transfemoral TAVR and one patient a transapical procedure. Edwards SAPIEN valve prosthesis was implanted in 8 (57%) patients and Medtronic CoreValve prosthesis in the remaining 6 (43%). Predefined performance success of the TriGuard™HDH device was achieved in 9 (64%) patients. The composite endpoint MACCE occurred in none of the patients. Post-procedural DWI was performed in 11 patients. Comparing the DWI of these patients to a historical control group showed no reduction in number [median 5.5 vs. 5.0, P = 0.857], however there was a significant reduction in mean lesion volume per patient [median 13.8 vs. 25.1, P = 0.049]. This study showed the feasibility and safety of using the TriGuard™HDH for cerebral protection during TAVR. This device did not decrease the number of post-procedural new cerebral DWI lesions, however its use showed decreased lesion volume as compared to unprotected TAVR. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Petit-Eisenmann, Hélène; Epailly, Eric; Velten, Michel; Radojevic, Jelena; Eisenmann, Bernard; Kremer, Hélène; Kindo, Michel
2016-12-01
The impact of prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) for aortic stenosis on exercise capacity remains controversial. The aim of this study was to analyze the long-term impact of PPM after mechanical AVR on maximal oxygen uptake (VO 2max ). The study included 75 patients who had undergone isolated mechanical AVR for aortic stenosis with normal left ventricular (LV) function between 1994 and 2012. Their functional capacity was evaluated on average 4.6 years after AVR by exercise testing, including measurement of their VO 2max , and by determining their New York Heart Association functional class and Short Form-36 score. Two groups were defined by measuring the patients' indexed effective orifice area (iEOA) by transthoracic echocardiography: a PPM group (iEOA < 0.85 cm 2 /m 2 ) and a no-PPM group (iEOA ≥ 0.85 cm 2 /m 2 ). PPM was present in 37.0% of the patients. The percentage of the predicted VO 2max achieved was significantly lower in the PPM group (86.7 ± 19.5% vs 97.5 ± 23.0% in the no-PPM group; P = 0.04). Compared with the no-PPM group, the PPM group contained fewer patients in New York Heart Association functional class I and their mean Short Form-36 physical component summary score was significantly lower. The mean transvalvular gradient was significantly higher in the PPM group than in the no-PPM group (P < 0.001). Systolic and diastolic function and LV mass had normalized in both groups. PPM is associated in the long term with moderate but significant impairment of functional capacity, despite optimal LV reverse remodelling and normalization of LV systolic and diastolic function. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Henein, Michael; Hällgren, Peter; Holmgren, Anders; Sörensen, Karen; Ibrahimi, Pranvera; Kofoed, Klaus Fuglsang; Larsen, Linnea Hornbech; Hassager, Christian
2015-12-01
The underlying pathology in aortic stenosis (AS) and coronary artery stenosis (CAS) is similar including atherosclerosis and calcification. We hypothesize that coronary artery calcification (CAC) is likely to correlate with aortic root calcification (ARC) rather than with aortic valve calcification (AVC), due to tissue similarity between the two types of vessel rather than with the valve leaflet tissue. We studied 212 consecutive patients (age 72.5 ± 7.9 years, 91 females) with AS requiring aortic valve replacement (AVR) in two Heart Centers, who underwent multidetector cardiac CT preoperatively. CAC, AVC and ARC were quantified using Agatston scoring. Correlations were tested by Spearman's test and Mann-Whitney U-test was used for comparing different subgroups; bicuspid (BAV) vs tricuspid (TAV) aortic valve. CAC was present in 92%, AVC in 100% and ARC in 82% of patients. CAC correlated with ARC (rho = 0.51, p < 0.001) but not with AVC. The number of calcified coronary arteries correlated with ARC (rho = 0.45, p < 0.001) but not with AVC. 29/152 patients had echocardiographic evidence of BAV and 123 TAV, who were older (p < 0.001) but CAC was associated with TAV even after adjusting for age (p = 0.01). AVC score was associated with BAV after adjusting for age (p = 0.03) but ARC was not. Of the total cohort, 82 patients (39%) had significant coronary stenosis (>50%), but these were not different in the pattern of calcification from those without CAS. CAC was consistently higher in patients with risk factors for atherosclerosis compared to those without. The observed relationship between coronary and aortic root calcification suggests a diffuse arterial disease. The lack of relationship between coronary and aortic valve calcification suggests a different pathology. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Kong, William K F; Regeer, Madelien V; Ng, Arnold C T; McCormack, Louise; Poh, Kian Keong; Yeo, Tiong Cheng; Shanks, Miriam; Parent, Sarah; Enache, Roxana; Popescu, Bogdan A; Yip, James W; Ma, Lawrence; Kamperidis, Vasileios; van der Velde, Enno T; Mertens, Bart; Ajmone Marsan, Nina; Delgado, Victoria; Bax, Jeroen J
2017-03-01
This large multicenter, international bicuspid aortic valve (BAV) registry aimed to define the sex differences in prevalence, valve morphology, dysfunction (aortic stenosis/regurgitation), aortopathy, and complications (endocarditis and aortic dissection). Demographic, clinical, and echocardiographic data at first presentation of 1992 patients with BAV (71.5% men) were retrospectively analyzed. BAV morphology and valve function were assessed; aortopathy configuration was defined as isolated dilatation of the sinus of Valsalva or sinotubular junction, isolated dilatation of the ascending aorta distal to the sinotubular junction, or diffuse dilatation of the aortic root and ascending aorta. New cases of endocarditis and aortic dissection were recorded. There were no significant sex differences regarding BAV morphology and frequency of normal valve function. When presenting with moderate/severe aortic valve dysfunction, men had more frequent aortic regurgitation than women (33.8% versus 22.2%, P <0.001), whereas women were more likely to have aortic stenosis (34.5% versus 44.1%, P <0.001). Men had more frequently isolated dilatation of the sinus of Valsalva or sinotubular junction (14.2% versus 6.7%, P <0.001) and diffuse dilatation of the aortic root and ascending aorta (16.2% versus 7.3%, P <0.001) than women. Endocarditis (4.5% versus 2.5%, P =0.037) and aortic dissections (0.5% versus 0%, P <0.001) occurred more frequently in men. Although there is a male predominance among patients with BAV, men with BAV had more frequently moderate/severe aortic regurgitation at first presentation compared with women, whereas women presented more often with moderate/severe aortic stenosis compared with men. Furthermore, men had more frequent aortopathy than women. © 2017 American Heart Association, Inc.
Ross procedure for ascending aortic replacement.
Elkins, R C; Lane, M M; McCue, C
1999-06-01
Patients with aortic valve disease and aneurysm or dilatation of the ascending aorta require both aortic valve replacement and treatment of their ascending aortic disease. In children and young adults, the Ross operation is preferred when the aortic valve requires replacement, but the efficacy of extending this operation to include replacement of the ascending aorta or reduction of the dilated aorta has not been tested. We reviewed the medical records of 18 (5.9%) patients with aortic valve disease and an ascending aortic aneurysm and 26 (8.5%) patients with dilation of the ascending aorta, subgroups of 307 patients who had a Ross operation between August 1986 and February 1998. We examined operative and midterm results, including recent echocardiographic assessment of autograft valve function and ability of the autograft root and ascending aortic repair or replacement to maintain normal structural integrity. There was one operative death (2%) related to a perioperative stroke. Forty-two of 43 survivors have normal autograft valve function, with trace to mild autograft valve insufficiency, and one patient has moderate insufficiency at the most recent echocardiographic evaluation. None of the patients has dilatation of the autograft root or of the replaced or reduced ascending aorta. Early results with extension of the Ross operation to include replacement of an ascending aortic aneurysm or vertical aortoplasty for reduction of a dilated ascending aorta are excellent, with autograft valve function equal to that seen in similar patients without ascending aortic disease.
Chen, Mei-Ling; Chen, Michael Y; Yin, Wei-Hsian; Wei, Jeng; Wang, Ji-Hung
2014-07-01
The Bentall procedure is the gold standard for treating aortic dissection complicated with valvular and ascending aorta disease. Recent results for this procedure have been excellent; nearly 100% of patients remain free of infective endocarditis in long-term follow-up. We report a case of delayed Streptococcus agalactiae infective endocarditis complicated by mycotic aneurysm in a man who had undergone the Bentall procedure with a mechanical valve conduit 15 years previously. The mycotic aneurysm was located in the remnant aortic root, below the mechanical valve conduit, and later ruptured into the right atrium. The patient was treated conservatively and survived the acute period. Later, the aortic root defect was repaired successfully by means of a hybrid technique using a Amplatzer duct occluder. Amplatzer duct occluder; Aortic dissection; Bentall technique; Infective endocarditis; Mycotic aneurysm.
Akpinar, B; Sanisoğlu, I; Konuralp, C; Akay, H; Güden, M; Sönmez, B
1999-01-01
Over the years, many surgical methods have evolved for the treatment of ascending aortic aneurysm in combination with aortic valve regurgitation; however, precise guidelines for optimal surgical techniques for varying presentations have not been defined. We describe the use of a stentless porcine bioprosthesis (Medtronic Freestyle) in a patient with an ascending aortic aneurysm and aortic regurgitation. We used the complete root replacement method, and anastomosed a Dacron graft (Hemashield) between the bioprosthetic valve and the native aorta to replace the distal part of the aneurysm. Images PMID:10524742
Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C
2018-05-01
Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the treatment of severe aortic stenosis in patients with intermediate surgical risk. There remains moderate-to-high uncertainty surrounding the base-case incremental cost-effectiveness ratio. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Linke, Axel; Walther, Thomas; Schuler, Gerhard
2010-03-01
Treatment of aortic stenosis remains challenging in older individuals, as their perioperative mortality for open heart surgery is increased due to comorbidities. Transcatheter aortic valve implantation using the CoreValve ReValving System (Medtronic, Minneapolis, USA) and the Edwards SAPIEN transcatheter heart valve (THV; Edwards Lifescience, Irvine, California, USA) represents an alternative to conventional valve replacement in elderly patients that have a high risk for conventional surgery. This article summarizes the evidence-base from recent clinical trials. The early results of these landmark studies suggest that transcatheter aortic valve implantation with either one of the prosthesis is feasible, safe, improves hemodynamics and, therefore, might be an alternative to conventional aortic valve replacement in very high-risk patients. However, all of the available transcatheter heart valves have certain disadvantages, limiting their use in daily clinical practice. The process of decision making, which valve to use and which access route to choose is illustrated in this article through clinical case scenarios. Additionally, the lessons learned thus far from the European perspective and the potential impact on the future use in the US are discussed. Despite of the progress in this field, we are still lacking an optimal transcatheter heart valve. Once it is available, we can take the plunge to compare transcatheter valve implantation with convention surgery in severe aortic stenosis!
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis.
Tasca, Giordano; Selmi, Matteo; Votta, Emiliano; Redaelli, Paola; Sturla, Francesco; Redaelli, Alberto; Gamba, Amando
2017-05-01
Aortic root aneurysm can be treated with valve-sparing procedures. The David and Yacoub techniques have shown excellent long-term results but are technically demanding. Recently, a new and simpler procedure, the Sleeve technique, was proposed with encouraging results. We aimed to quantify the biomechanics of the initially aneurysmal aortic root (AR) after the Sleeve procedure to assess whether it induces abnormal stresses, potentially undermining its durability. Two finite element (FE) models of the physiologic and aneurysmal AR were built, accounting for the anatomical asymmetry and the nonlinear and anisotropic mechanical properties of human AR tissues. On the aneurysmal model, the Sleeve and David techniques were simulated based on the corresponding published technical features. Aortic root biomechanics throughout 2 consecutive cardiac cycles were computed in each simulated configuration. Both sparing techniques restored physiologic-like kinematics of aortic valve (AV) leaflets but induced different leaflets stresses. The time course averaged over the leaflets' bellies was 35% higher in the David model than in the Sleeve model. Commissural stresses, which were equal to 153 and 318 kPa in the physiologic and aneurysmal models, respectively, became 369 and 208 kPa in the David and Sleeve models, respectively. No intrinsic structural problems were detected in the Sleeve model that might jeopardize the durability of the procedure. If corroborated by long-term clinical outcomes, the results obtained suggest that using this new technique could successfully simplify the surgical repair of AR aneurysms and reduce intraoperative complications. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Fiorina, Claudia; Maffeo, Diego; Curello, Salvatore; Lipartiti, Felicia; Chizzola, Giuliano; D'Aloia, Antonio; Adamo, Marianna; Mastropierro, Rosy; Gavazzi, Emanuele; Ciccarese, Camilla; Chiari, Ermanna; Ettori, Federica
2014-06-01
Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85%vs.64%,p=0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL≥2;9%vs.33%,p=0.02). Safety combined end point at 30 days was similar in both groups. Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups. Copyright © 2014 Elsevier Inc. All rights reserved.
Franken, Romy; Teixido-Tura, Gisela; Brion, Maria; Forteza, Alberto; Rodriguez-Palomares, Jose; Gutierrez, Laura; Garcia Dorado, David; Pals, Gerard; Mulder, Barbara Jm; Evangelista, Artur
2017-11-01
The effect of FBN1 mutation type on the severity of cardiovascular manifestations in patients with Marfan syndrome (MFS) has been reported with disparity results. This study aims to determine the impact of the FBN1 mutation type on aortic diameters, aortic dilation rates and on cardiovascular events (ie, aortic dissection and cardiovascular mortality). MFS patients with a pathogenic FBN1 mutation followed at two specialised units were included. FBN1 mutations were classified as being dominant negative (DN; incorporation of non-mutated and mutated fibrillin-1 in the extracellular matrix) or having haploinsufficiency (HI; only incorporation of non-mutated fibrillin-1, thus a decreased amount of fibrillin-1 protein). Aortic diameters and the aortic dilation rate at the level of the aortic root, ascending aorta, arch, descending thoracic aorta and abdominal aorta by echocardiography and clinical endpoints comprising dissection and death were compared between HI and DN patients. Two hundred and ninety patients with MFS were included: 113 (39%) with an HI- FBN1 mutation and 177 (61%) with a DN- FBN1 . At baseline, patients with HI- FBN1 had a larger aortic root diameter than patients with DN- FBN1 (HI: 39.3±7.2 mm vs DN: 37.3±6.8 mm, p=0.022), with no differences in age or body surface area. After a mean follow-up of 4.9±2.0 years, aortic root and ascending dilation rates were increased in patients with HI- FBN1 (HI: 0.57±0.8 vs DN: 0.28±0.5 mm/year, p=0.004 and HI: 0.59±0.9 vs DN: 0.30±0.7 mm/year, p=0.032, respectively). Furthermore, patients with HI- FBN1 tended to be at increased risk for the combined endpoint of dissection and death compared with patients with DN- FBN1 (HR: 3.3, 95% CI 1.0 to 11.4, p=0.060). Patients with an HI mutation had a more severely affected aortic phenotype, with larger aortic root diameters and a more rapid dilation rate, and tended to have an increased risk of death and dissections compared with patients with a DN mutation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[Status of aortic valve reconstruction and Ross operation in aortic valve diseases].
Sievers, Hans H
2002-08-01
At first glance the aortic valve is a relative simple valve mechanism connecting the left ventricle and the ascending aorta. Detailed analysis of the different components of the aortic valve including the leaflets and sinuses revealed a complex motion of each part leading to a perfect durable valve mechanism at rest and during exercise. Theoretically, the reconstruction or imitation of these structures in patients with aortic valve disease should lead to optimal results. Prerequisite is the exact knowledge of the important functional characteristics of the aortic valve. The dynamic behavior of the aortic root closely harmonizing with the leaflets not only warrants stress minimizing and valve durability, but also optimizes coronary flow, left ventricular function and aortic impedance. The newly discovered contractile capacity of the leaflets and the root components are important for tuning the dynamics. Isolated reconstruction of the aortic valve such as decalcification, commissurotomy, plication of ring or leaflets of a tricuspid aortic valve and cusp extension are seldom indicated in contrast to the reconstruction of the bicuspid insufficient valve. Proper indication and skilled techniques lead to excellent hemodynamic and clinical intermediate-term result up to 7 years after reconstruction. Latest follow-up revealed a mean aortic insufficiency of 0.7, maximal pressure gradient of 11.4 +/- 8.5 mm Hg with zero hospital or late mortality, reoperation or thromboembolic events in 22 patients. The reconstructive techniques for aortic root aneurysm and/or type A dissection according to David or Yacoub have become routine procedures in the last 10 years. The hemodynamic and clinical results are excellent with low reoperation rate and very low risk of thromboembolism. Generally, a maximal diameter of the root of 5 cm is indicative for performing the operation. In patients with Marfan's syndrome the reconstruction should be advanced even with smaller diameters especially if these are progressive and combined with aortic insufficiency. ROSS-OPERATION: The Ross-Operation includes the replacement of the diseased aortic valve with the pulmonary autograft and reconstruction of the right ventricular outflow tract using a homograft. The hemodynamic results are excellent regarding the autograft and also the clinical results with very low thromboembolic risk and acceptable reoperation rate. This method is especially indicated for active young patients, women, who desire children, athletes and patients in general, who like to avoid long-term anticoagulation. In some cases the homograft may develop a dysfunction predominantly a pulmonary stenosis requiring reoperation. In the author's series of 245 Ross-operations in 12 years the homograft had to be replaced in 4 cases without letality. Innovative, decellularized homografts with the potential to repopulate with autologeous cells show promising results after 1 year of clinical implantation without signs of antibody development. Probably these tissue-engineered modification may improve the homograft results. The reconstructive techniques of the aortic valve and the Ross-operation have a certain risk of reoperation that must be weighed against the advantages of very low hospital and late valve related death, excellent hemodynamics, very low risk of macro- and microembolism as well as bleeding, lack of long-term anticoagulation and unrestricted life-style.
Ascending aortic aneurysm causing hoarse voice: a variant of Ortner's syndrome
Eccles, Sinan Robert; Banks, John; Kumar, Pankaj
2012-01-01
A 68-year-old man with a persistent hoarse voice was found to have a left vocal cord paralysis. Clinical examination revealed signs consistent with aortic regurgitation. Subsequent investigation revealed an ascending aortic aneurysm. He underwent aortic root and ascending aorta replacement and his hoarseness improved. Ortner's syndrome refers to hoarseness due to recurrent laryngeal nerve palsy secondary to a cardiovascular abnormality. Recurrent laryngeal nerve palsy due to aneurysmal dilation of the ascending aorta is extremely rare, with aneurysms of the aortic arch being a more common cause. PMID:23060380
Selamet Tierney, Elif Seda; Levine, Jami C.; Chen, Shan; Bradley, Timothy J.; Pearson, Gail D.; Colan, Steven D.; Sleeper, Lynn A.; Campbell, M. Jay; Cohen, Meryl S.; Backer, Julie De; Guey, Lin T.; Heydarian, Haleh; Lai, Wyman W.; Lewin, Mark B.; Marcus, Edward; Mart, Christopher R.; Pignatelli, Ricardo H.; Printz, Beth F.; Sharkey, Angela M.; Shirali, Girish S.; Srivastava, Shubhika; Lacro, Ronald V.
2013-01-01
Background The Pediatric Heart Network is conducting a large international randomized trial to compare aortic root growth and other cardiovascular outcomes in 608 subjects with Marfan syndrome randomized to receive atenolol or losartan for 3 years. The authors report here the echocardiographic methods and baseline echocardiographic characteristics of the randomized subjects, describe the interobserver agreement of aortic measurements, and identify factors influencing agreement. Methods Individuals aged 6 months to 25 years who met the original Ghent criteria and had body surface area–adjusted maximum aortic root diameter (ROOTmax) Z scores > 3 were eligible for inclusion. The primary outcome measure for the trial is the change over time in ROOTmax Z score. A detailed echocardiographic protocol was established and implemented across 22 centers, with an extensive training and quality review process. Results Interobserver agreement for the aortic measurements was excellent, with intraclass correlation coefficients ranging from 0.921 to 0.989. Lower interobserver percentage error in ROOTmax measurements was independently associated (model R2 = 0.15) with better image quality (P = .002) and later study reading date (P < .001). Echocardiographic characteristics of the randomized subjects did not differ by treatment arm. Subjects with ROOTmax Z scores ≥ 4.5 (36%) were more likely to have mitral valve prolapse and dilation of the main pulmonary artery and left ventricle, but there were no differences in aortic regurgitation, aortic stiffness indices, mitral regurgitation, or left ventricular function compared with subjects with ROOTmax Z scores < 4.5. Conclusions The echocardiographic methodology, training, and quality review process resulted in a robust evaluation of aortic root dimensions, with excellent reproducibility. PMID:23582510
Trapeaux, J; Busseuil, D; Shi, Y; Nobari, S; Shustik, D; Mecteau, M; El-Hamamsy, I; Lebel, M; Mongrain, R; Rhéaume, E; Tardif, J-C
2013-01-01
Background and Purpose We have shown that infusions of apolipoprotein A-I (ApoA-I) mimetic peptide induced regression of aortic valve stenosis (AVS) in rabbits. This study aimed at determining the effects of ApoA-I mimetic therapy in mice with calcific or fibrotic AVS. Experimental Approach Apolipoprotein E-deficient (ApoE−/−) mice and mice with Werner progeria gene deletion (WrnΔhel/Δhel) received high-fat diets for 20 weeks. After developing AVS, mice were randomized to receive saline (placebo group) or ApoA-I mimetic peptide infusions (ApoA-I treated groups, 100 mg·kg−1 for ApoE−/− mice; 50 mg·kg−1 for Wrn mice), three times per week for 4 weeks. We evaluated effects on AVS using serial echocardiograms and valve histology. Key Results Aortic valve area (AVA) increased in both ApoE−/− and Wrn mice treated with the ApoA-I mimetic compared with placebo. Maximal sinus wall thickness was lower in ApoA-I treated ApoE−/− mice. The type I/III collagen ratio was lower in the sinus wall of ApoA-I treated ApoE−/− mice compared with placebo. Total collagen content was reduced in aortic valves of ApoA-I treated Wrn mice. Our 3D computer model and numerical simulations confirmed that the reduction in aortic root wall thickness resulted in improved AVA. Conclusions and Implications ApoA-I mimetic treatment reduced AVS by decreasing remodelling and fibrosis of the aortic root and valve in mice. PMID:23638718
When Not to Go SOLO? Contraindications Based on Implant Experience.
Wollersheim, Laurens W; Li, Wilson W; Kaya, Abdullah; van Boven, Wim J; van der Meulen, Jan; de Mol, Bas A
2016-11-01
Because of the design and specific implantation technique of the stentless Freedom SOLO bioprosthesis, patient selection is crucial. The aim of the study was to discuss the contraindications to this prosthesis based on the authors' implant experience. Between April 2005 and February 2015, one surgeon at the authors' center performed 292 aortic valve replacements using a bioprosthesis, with the initial intention of implanting a SOLO valve in every patient. A search was conducted for all of these patients and data collected on whether a SOLO valve was used, or not. A SOLO valve was implanted in 238 patients (82%), and a stented bioprosthesis in 54 (18%). The predominant reasons not to implant a SOLO valve were asymmetric commissures (26%) and a large aortic annulus (24%). Only one patient had structural valve deterioration, and none of the patients had to undergo reoperation because of aortic valve insufficiency or paravalvular leakage. Asymmetric commissures, large aortic annulus (>27 mm), calcified aortic sinuses, dilated sinotubular junction, aberrant location of coronary ostia and whenever the stent of a stented bioprosthesis is useful, were contraindications to implant a SOLO valve. When these contraindications were taken into account, a very good durability could be achieved with the SOLO valve during mid-term follow up.
Diminutive Porcelain Ascending Aorta With Supravalvular Aortic Stenosis.
Houmsse, Mustafa; McDavid, Asia; Kilic, Ahmet
2018-05-01
This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Early and late outcomes of 1000 minimally invasive aortic valve operations.
Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F
2008-04-01
Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.
Hussein, Nabil; Qamar, Sombul; Abid, Qamar
2015-01-01
Aspergillus infections such as Aspergillus endocarditis were once relatively rare occurrences, however, due to the increased use of intracardiac devices, the incidence has grown. With mortality rates close to 100%, in medically treated cases, it is paramount that early diagnosis and treatment are performed. An immunocompetent aviculturist presented 8 months post aortic root replacement for severe aortic regurgitation with a composite graft, with central crushing chest pain. Investigations confirmed ST elevation inferior myocardial infarction due to stenosis of the origin of the right coronary artery, which was stented. Echocardiogram demonstrated a mobile mass posterior to the left ventricular outflow tract. Following referral to our cardiothoracic surgeons, a polypoidal mass covering the right ostial button was noted along with systemic complications of the disease. Emergency redo aortic valve replacement with a homograft and coronary artery bypass was performed. Histological analysis confirmed A. fumigatus and the patient was started on intravenous voriconazole. PMID:26025972
Ouweneel, Dagmar M; Sjauw, Krischan D; Wiegerinck, Esther M A; Hirsch, Alexander; Baan, Jan; de Mol, Bas A J M; Lagrand, Wim K; Planken, R Nils; Henriques, José P S
2016-10-01
The use of intracardiac assist devices is expanding, and correct position of these devices is required for optimal functioning. The aortic valve is an important landmark for positioning of those devices. It would be of great value if the device position could be easily monitored on plain supine chest radiograph in the ICU. We introduce a ratio-based tool for determination of the aortic valve location on plain supine chest radiograph images, which can be used to evaluate intracardiac device position. Retrospective observational study. Large academic medical center. Patients admitted to the ICU and supported by an intracardiac assist device. We developed a ratio to determine the aortic valve location on supine chest radiograph images. This ratio is used to assess the position of a cardiac assist device and is compared with echocardiographic findings. Supine anterior-posterior chest radiographs of patients with an aortic valve prosthesis (n = 473) were analyzed to determine the location of the aortic valve. We calculated several ratios with the potential to determine the position of the aortic valve. The aortic valve location ratio, defined as the distance between the carina and the aortic valve, divided by the thoracic width, was found to be the best performing ratio. The aortic valve location ratio determines the location of the aortic valve caudal to the carina, at a distance of 0.25 ± 0.05 times the thoracic width for male patients and 0.28 ± 0.05 times the thoracic width for female patients. The aortic valve location ratio was validated using CT images of patients with angina pectoris without known valvular disease (n = 95). There was a good correlation between cardiac device position (Impella) assessed with the aortic valve location ratio and with echocardiography (n = 53). The aortic valve location ratio enables accurate and reproducible localization of the aortic valve on supine chest radiograph. This tool is easily applicable and can be used for assessment of cardiac device position in patients on the ICU.
Pannus-related prosthetic valve dysfunction. Case report
MOLDOVAN, MARIA-SÎNZIANA; BEDELEANU, DANIELA; KOVACS, EMESE; CIUMĂRNEAN, LORENA; MOLNAR, ADRIAN
2016-01-01
Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction. PMID:27004041
Pannus-related prosthetic valve dysfunction. Case report.
Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian
2016-01-01
Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.
Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf
2012-08-01
Transapical (TA) aortic valve implantation (AVI) has evolved as an alternative procedure for high-risk patients. We evaluated the second-generation SAPIEN XT™ prosthesis in a prospective multicentre clinical trial. A total of 150 patients (age: 81.6 ± 5.8 years; 40.7% female) were included. Prosthetic valves (diameter: 23 mm (n = 36), 26 mm (n = 57) and 29 mm (n = 57)) were implanted. The ASCENDRA-II™ modified delivery system was used in the smaller sizes. Mean logistic EuroSCORE was 24.3 ± 7.0%, and mean STS score 7.5 ± 4.4%. All patients gave written informed consent. Off-pump AVI was performed using femoral arterial and venous access wires as a safety net. All but two patients received TA-AVI, as planned. The 29-mm valve showed similar function as the values of two other diameters did. Three patients (2%) required temporary cardiopulmonary bypass support. Postoperative complications included renal failure requiring long-term dialysis in four, bleeding requiring rethoracotomy in four, respiratory complication requiring reintubation in eight and sepsis in four patients, respectively. Thirty-day mortality was 13 (8.7%) for the total cohort and 2/57 (3.5%) for patients receiving the 29-mm valve, respectively. Echocardiography at discharge showed none or trivial aortic incompetence (AI) in 71% and mild-AI in 22% of the patients. Post-implantation AI was predominantly paravalvular and ≥ 2+ in 7% of patients. One patient required reoperation for AI within 30 days. The PREVAIL TA multicentre trial demonstrates good functionality and good outcomes for TA-AVI, using the SAPIEN XT™ prosthesis and its second-generation ASCENDRA-II™ delivery system, as well successful introduction of the 29-mm SAPIEN XT™ valve for the benefit of high-risk elderly patients.
2012-01-01
Background Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media. PMID:22453050
Kahlert, Philipp; Parohl, Nina; Albert, Juliane; Schäfer, Lena; Reinhardt, Renate; Kaiser, Gernot M; McDougall, Ian; Decker, Brad; Plicht, Björn; Erbel, Raimund; Eggebrecht, Holger; Ladd, Mark E; Quick, Harald H
2012-03-27
Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.
Changes in turbulence with rotation of the omnicarbon prosthesis.
Travis, Brandon R; Nyboe, Camilla; Christensen, Thomas D; Smerup, Morten; Johansen, Peter; Nygaard, Hans; Hasenkam, J Michael
2007-01-01
This study was performed to determine whether annular plane orientation of the Omnicarbon aortic valve influences forward flow turbulence. The Omnicarbon prostheses was modified to allow in situ manual rotation of the valve when implanted in the aortic position of eight 90 kg pigs. Pulsed Doppler ultrasound was used to acquire velocity measurements at 17 locations within the cross-sectional area of the ascending aorta. In each animal, 12 valve rotations were tested in this manner. Reynolds normal stresses were estimated from the velocity measurements. High Reynolds normal stresses were concentrated between left and posterior-right sides of the aortic wall for all orientations studied. No trends in mean or maximum Reynolds normal stresses with respect to valve rotation were consistent in the experiments. Unlike previous experiments with the Medtronic-Hall tilting disc valve, these experiments showed no notable changes in Reynolds normal stress with respect to orientation of the Omnicarbon valve. This suggests that the tendency of turbulent stresses to change with tilting disc valve orientation may be dependent on valve design.
Ureaplasma parvum causing life-threatening disease in a susceptible patient.
Korytny, Alexander; Nasser, Roni; Geffen, Yuval; Friedman, Tom; Paul, Mical; Ghanem-Zoubi, Nesrin
2017-08-16
A 56-year-old man with lymphoma developed orchitis followed by septic arthritis of his right glenohumeral joint. Synovial fluid cultures were negative but PCR amplification test was positive for Ureaplasmaparvum. The patient was treated with doxycycline. Two and a half years later, the patient presented with shortness of breath and grade III/IV diastolic murmur on auscultation. Echocardiography revealed severely dilated left heart chambers, severe aortic regurgitation and several mobile masses on the aortic valve cusps suspected to be vegetations. He underwent valve replacement; valve tissue culture was negative but the 16S rRNA gene amplification test was positive for U. parvum He was treated again with doxycycline. In an outpatient follow-up 1 year and 3 months later, the patient was doing well. Repeated echocardiography showed normal aortic prosthesis function. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Predictive risk models for proximal aortic surgery
Díaz, Rocío; Pascual, Isaac; Álvarez, Rubén; Alperi, Alberto; Rozado, Jose; Morales, Carlos; Silva, Jacobo; Morís, César
2017-01-01
Predictive risk models help improve decision making, information to our patients and quality control comparing results between surgeons and between institutions. The use of these models promotes competitiveness and led to increasingly better results. All these virtues are of utmost importance when the surgical operation entails high-risk. Although proximal aortic surgery is less frequent than other cardiac surgery operations, this procedure itself is more challenging and technically demanding than other common cardiac surgery techniques. The aim of this study is to review the current status of predictive risk models for patients who undergo proximal aortic surgery, which means aortic root replacement, supracoronary ascending aortic replacement or aortic arch surgery. PMID:28616348
Jacobs, Jeffrey Phillip; Edwards, Fred H; Shahian, David M; Prager, Richard L; Wright, Cameron D; Puskas, John D; Morales, David L S; Gammie, James S; Sanchez, Juan A; Haan, Constance K; Badhwar, Vinay; George, Kristopher M; O'Brien, Sean M; Dokholyan, Rachel S; Sheng, Shubin; Peterson, Eric D; Shewan, Cynthia M; Feehan, Kelly M; Han, Jane M; Jacobs, Marshall Lewis; Williams, William G; Mayer, John E; Chitwood, W Randolph; Murray, Gordon F; Grover, Frederick L
2011-07-01
Long-term evaluation of cardiothoracic surgical outcomes is a major goal of The Society of Thoracic Surgeons (STS). Linking the STS Database to the Social Security Death Master File (SSDMF) allows for the verification of "life status." This study demonstrates the feasibility of linking the STS Database to the SSDMF and examines longitudinal survival after cardiac operations. For all operations in the STS Adult Cardiac Surgery Database performed in 2008 in patients with an available Social Security Number, the SSDMF was searched for a matching Social Security Number. Survival probabilities at 30 days and 1 year were estimated for nine common operations. A Social Security Number was available for 101,188 patients undergoing isolated coronary artery bypass grafting, 12,336 patients undergoing isolated aortic valve replacement, and 6,085 patients undergoing isolated mitral valve operations. One-year survival for isolated coronary artery bypass grafting was 88.9% (6,529 of 7,344) with all vein grafts, 95.2% (84,696 of 88,966) with a single mammary artery graft, 97.4% (4,422 of 4,540) with bilateral mammary artery grafts, and 95.6% (7,543 of 7,890) with all arterial grafts. One-year survival was 92.4% (11,398 of 12,336) for isolated aortic valve replacement (95.6% [2,109 of 2,206] with mechanical prosthesis and 91.7% [9,289 of 10,130] with biologic prosthesis), 86.5% (2,312 of 2,674) for isolated mitral valve replacement (91.7% [923 of 1,006] with mechanical prosthesis and 83.3% [1,389 of 1,668] with biologic prosthesis), and 96.0% (3,275 of 3,411) for isolated mitral valve repair. Successful linkage to the SSDMF has substantially increased the power of the STS Database. These longitudinal survival data from this large multi-institutional study provide reassurance about the durability and long-term benefits of cardiac operations and constitute a contemporary benchmark for survival after cardiac operations. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Forteza, Alberto; Evangelista, Arturo; Sánchez, Violeta; Teixidó-Turà, Gisela; Sanz, Paz; Gutiérrez, Laura; Gracia, Teresa; Centeno, Jorge; Rodríguez-Palomares, José; Rufilanchas, Juan Jose; Cortina, José; Ferreira-González, Ignacio; García-Dorado, David
2016-03-21
To determine the efficacy of losartan vs. atenolol in aortic dilation progression in Marfan syndrome (MFS) patients. A phase IIIb, randomized, parallel, double-blind study was conducted in 140 MFS patients, age range: 5-60 years, with maximum aortic diameter <45 mm who received losartan (n = 70) or atenolol (n = 70). Doses were raised to a maximum of 1.4 mg/kg/day or 100 mg/day. The primary end-point was the change in aortic root and ascending aorta maximum diameter indexed by body surface area on magnetic resonance imaging after 36 months of treatment. No serious drug-related adverse effects were observed. Five patients presented aortic events during a follow-up (one in the losartan and four in the atenolol groups, P = 0.366). After 3 years of follow-up, aortic root diameter increased significantly in both groups: 1.1 mm (95% CI 0.6-1.6) in the losartan and 1.4 mm (95% CI 0.9-1.9) in the atenolol group, with aortic dilatation progression being similar in both groups: absolute difference between losartan and atenolol -0.3 mm (95% CI -1.1 to 0.4, P = 0.382) and indexed by BSA -0.5 mm/m2 (95% CI -1.2 to 0.1, P = 0.092). Similarly, no significant differences were found in indexed ascending aorta diameter changes between the losartan and atenolol groups: -0.3 mm/m2 (95% CI -0.8 to 0.3, P = 0.326). Among patients with MFS, the use of losartan compared with atenolol did not result in significant differences in the progression of aortic root and ascending aorta diameters over 3 years of follow-up. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
Pregnancy-related acute aortic dissection in Marfan syndrome: A review of the literature.
Smith, Katherine; Gros, Bernard
2017-05-01
A well-established association exists between acute aortic dissection and pregnancy, particularly in women with Marfan syndrome. However, there is debate regarding appropriate management guidelines. In particular, there are differing opinions regarding when prophylactic aortic root repair should be recommended as well as the efficacy of beta blockers in this clinical scenario. The current study evaluated 10 years of published literature (2005-2015) in the PubMed/Medline database. Fifty articles, describing 72 cases of women who presented with aortic dissection in the antepartum or postpartum period were identified. Comparisons on demographic variables and clinical outcomes between cases of women with Marfan syndrome (n = 36) and without Marfan syndrome (n = 36) were conducted. There were no significant differences in demographics (age, gravidity, parity) between the Marfan and non-Marfan cases. Marfan patients presented with antepartum dissections significantly earlier in pregnancy than those without Marfan syndrome (P = .002). However, there were no significant difference between the 2 groups in maternal mortality, fetal mortality, or obstetric outcomes (mode of delivery and gestational age at delivery). Eight cases described events in Marfan women with an aortic root diameter ≤40 mm. Six events occurred in Marfan women who were managed with beta blockers. Current guidelines rely on aortic root diameter for stratification of Marfan women into risk categories, but we identified several cases that would be missed by these guidelines. Specifically, the existing literature suggest that women with Marfan syndrome should take precautions throughout pregnancy, rather than the third trimester. © 2017 Wiley Periodicals, Inc.
[Indications for and clinical outcome of the Ross procedure: a review].
Morita, K; Kurosawa, H
2001-04-01
The Ross procedure has been used increasingly to treat aortic valve disease in children and young adults. The primary indication for the Ross procedure is to provide a permanent valve replacement in children with congenital aortic stenosis. More recently, it has been extended to young adults with a bicuspid aortic valve and small aortic annulus, especially women wishing to have children. Other possible indications include complex left ventricular outflow obstructive disease, native or prosthetic valve endocarditis, and adult aortic insufficiency with a dilated aortic annulus. Conversely, Marfan syndrome is considered to an absolute contraindication, and this procedure should be used with caution in patients with rheumatic valve disease and a dysplastic dilated aortic root because of the higher associated incidence of autograft dysfunction. The technique of total aortic root replacement has become the preferred method of autograft implantation, because it carries the lowest risk of pulmonary autograft failure. In patients with marked graft-host size mismatch, either concomitant aortic annulus reduction and fixation or aortic annulus enlargement (i.e., the Ross-Konno procedure) should be performed. The Ross Procedure International Registry data document that in the modern era (post-1986) the early and late mortality rate is 2.5% and 1%, respectively. Excellent long-term results have been reported, and the benefits of this procedure include optimal hemodynamics, low risk of endocarditis, resistance to infection in patients with active endocarditis, and nonthrombogeneicity and therefore few anticoagulation-related complications. The Ross procedure can be performed with acceptable early and mid-term mortality and excellent autograft durability. Further long-term follow-up will confirm the role of this procedure in patients with various types of aortic valve disease.
Lenoir, Marien; Maesen, Bart; Stevens, Louis-Mathieu; Cartier, Raymond; Demers, Philippe; Poirier, Nancy; Tousch, Michaël; El-Hamamsy, Ismail
2018-02-08
Remodelling with extra-aortic ring annuloplasty has emerged as an alternative approach to root reimplantation. However, no studies have yet compared outcomes between procedures. The aim of this study was to compare mid-term outcomes in patients undergoing reimplantation versus remodelling with extra-aortic annuloplasty. From 2001 to 2017, 142 patients underwent root remodelling with extra-aortic annuloplasty (n = 83, 48 ± 13 years) or a reimplantation technique (n = 59, 48 ± 12 years) at the Montreal Heart Institute. No differences were observed in the incidence of connective tissue disease (24% vs 29%, P = 0.9) or preoperative aortic insufficiency ≥3 (37% vs 23%, P = 0.24). However, in the remodelling group, there were more bicuspid aortic valves (31% vs 9%; P < 0.01), and the mean preoperative aortic annulus diameter was larger (27.2 ± 3.6 mm vs 25.6 ± 2.4 mm; P = 0.01). The mean follow-up duration was 3.9 years (100% complete). There were no hospital deaths and 5 late deaths. At 5 years, overall survival was similar in both groups (100%, P = 0.98). Similarly, 5-year freedom from aortic valve reoperation was equivalent (97 ± 2% in both groups, P = 0.95). Furthermore, 5-year survival free from aortic insufficiency ≥2 or reoperation was 84 ± 5% in the remodelling with annuloplasty group vs 83 ± 6% in the reimplantation group (P = 0.62). The mean annular diameter was 24.3 ± 0.5 mm at 5 years vs 23.6 ± 0.3 mm at discharge in the remodelling group (P = 0.28) and 24.4 ± 0.6 mm vs 23.2 ± 0.3 mm, respectively, in the reimplantation group (P = 0.1). Despite a higher prevalence of bicuspid aortic valves and larger aortic annular diameters, mid-term outcomes after remodelling with extra-aortic annuloplasty and reimplantation are comparable. Extra-aortic ring annuloplasty is effective at stabilizing annular dimensions. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Ritter, Alyssa; Atzinger, Carrie; Hays, Brandon; James, Jeanne; Shikany, Amy; Neilson, Derek; Martin, Lisa; Weaver, Kathryn Nicole
2017-06-01
Hypermobile Ehlers-Danlos syndrome (hEDS) is a common inherited connective tissue disorder characterized by joint hypermobility. The natural history of aortic root dilation (AoD), a potential complication of EDS, has not been well characterized in this population. We describe the natural history of aortic root size in a large cohort of patients with hEDS. A cohort of 325 patients with HEDS was identified at Cincinnati Children's Hospital Medical Center (CCHMC), including 163 patients from a previous study. Medical records were reviewed and each participant's height, weight, and aortic dimensions from up to four echocardiograms were documented. Aortic root z-scores were calculated using two established formulas based on age (Boston or Devereux). Overall prevalence of AoD and prevalence by age were calculated and longitudinal regression was performed. The prevalence of AoD with a z-score ≥ 2.0 was 14.2% (46/325) and with a z-score of ≥3.0 was 5.5% (18/325). No significant increases in z-score were seen over time for patients with multiple echocardiograms. Participants under the age of 15 years had an average decline of 0.1 standard deviations (SDs)/year. No significant change was found after 15 of age. Between the ages of 15 and 21 years, Boston z-scores were 0.96 higher than Devereux z-scores. The nearly 1 z-score unit difference between formulas indicates caution prior to diagnosing AoD in patients with hEDS. In light of the low prevalence and lack of progression of AoD, routine echocardiograms may not be warranted for pediatric patients with hEDS. © 2017 Wiley Periodicals, Inc.
Does altered aortic flow in marfan syndrome relate to aortic root dilatation?
Wang, Hung-Hsuan; Chiu, Hsin-Hui; Tseng, Wen-Yih Isaac; Peng, Hsu-Hsia
2016-08-01
To examine possible hemodynamic alterations in adolescent to adult Marfan syndrome (MFS) patients with aortic root dilatation. Four-dimensional flow MRI was performed in 20 MFS patients and 12 age-matched normal subjects with a 3T system. The cross-sectional areas of 10 planes along the aorta were segmented for calculating the axial and circumferential wall shear stress (WSSaxial , WSScirc ), oscillatory shear index (OSIaxial , OSIcirc ), and the nonroundness (NR), presenting the asymmetry of segmental WSS. Pearson's correlation analysis was performed to present the correlations between the quantified indices and the body surface area (BSA), aortic root diameter (ARD), and Z score of the ARD. P < 0.05 indicated statistical significance. Patients exhibited lower WSSaxial in the aortic root and the WSScirc in the arch (P < 0.05-0.001). MFS patients exhibited higher OSIaxial and OSIcirc in the sinotubular junction and arch, but lower OSIcirc in the descending aorta (all P < 0.05). The NR values were lower in patients (P < 0.05). The WSSaxial or WSScirc exhibited moderate to strong correlations with BSA, ARD, or Z score (R(2) = 0.50-0.72) in MFS patients. The significant differences in the quantified indices, which were associated with BSA, ARD, or Z score, in MFS were opposite to previous reports for younger MFS patients, indicating that altered flows in MFS patients may depend on the disease progress. The possible time dependency of hemodynamic alterations in MFS patients strongly suggests that longitudinal follow-up of 4D Flow is needed to comprehend disease progress. J. Magn. Reson. Imaging 2016;44:500-508. © 2016 Wiley Periodicals, Inc.
Does altered aortic flow in marfan syndrome relate to aortic root dilatation?
Wang, Hung‐Hsuan; Chiu, Hsin‐Hui; Tseng, Wen‐Yih Isaac
2016-01-01
Purpose To examine possible hemodynamic alterations in adolescent to adult Marfan syndrome (MFS) patients with aortic root dilatation. Materials and Methods Four‐dimensional flow MRI was performed in 20 MFS patients and 12 age‐matched normal subjects with a 3T system. The cross‐sectional areas of 10 planes along the aorta were segmented for calculating the axial and circumferential wall shear stress (WSSaxial, WSScirc), oscillatory shear index (OSIaxial, OSIcirc), and the nonroundness (NR), presenting the asymmetry of segmental WSS. Pearson's correlation analysis was performed to present the correlations between the quantified indices and the body surface area (BSA), aortic root diameter (ARD), and Z score of the ARD. P < 0.05 indicated statistical significance. Results Patients exhibited lower WSSaxial in the aortic root and the WSScirc in the arch (P < 0.05–0.001). MFS patients exhibited higher OSIaxial and OSIcirc in the sinotubular junction and arch, but lower OSIcirc in the descending aorta (all P < 0.05). The NR values were lower in patients (P < 0.05). The WSSaxial or WSScirc exhibited moderate to strong correlations with BSA, ARD, or Z score (R2 = 0.50–0.72) in MFS patients. Conclusion The significant differences in the quantified indices, which were associated with BSA, ARD, or Z score, in MFS were opposite to previous reports for younger MFS patients, indicating that altered flows in MFS patients may depend on the disease progress. The possible time dependency of hemodynamic alterations in MFS patients strongly suggests that longitudinal follow‐up of 4D Flow is needed to comprehend disease progress. J. Magn. Reson. Imaging 2016;44:500–508. PMID:26854646
Gambarin, Fabiana I; Favalli, Valentina; Serio, Alessandra; Regazzi, Mario; Pasotti, Michele; Klersy, Catherine; Dore, Roberto; Mannarino, Savina; Viganò, Mario; Odero, Attilio; Amato, Simona; Tavazzi, Luigi; Arbustini, Eloisa
2009-04-01
The major clinical problem of Marfan syndrome (MFS) is the aortic root aneurysm, with risk of dissection when the root diameter approximates 5 cm. In MFS, a key molecule, transforming growth factor-beta (TGF-beta), normally bound to the extracellular matrix, is free and activated. In an experimental setting, TGF-beta blockade prevents the aortic root structural damage and dilatation. The angiotensin receptor 1 blockers (sartanics) exert an anti-TGF-beta effect; trials are now ongoing for evaluating the effect of losartan compared with atenolol in MFS. beta-Adrenergic blockers are the drugs most commonly used in MFS. The third-generation beta-adrenergic blocker nebivolol retains the beta-adrenergic blocker effects on heart rate and further exerts antistiffness effects, typically increased in MFS. The open-label phase III study will include 291 patients with MFS and proven FBN1 gene mutations, with aortic root dilation (z-score > or =2.5). The patients will be randomized to nebivolol, losartan and the combination of the two drugs. The primary end point is the comparative evaluation of the effects of losartan, nebivolol and the association of both on the progression of aortic root growth rate. Secondary end points include the pharmacokinetics of the two drugs, comparative evaluation of serum levels of total and active TGF-beta, quantitative assessment of the expression of the mutated gene (FBN1, both 5' and 3'), pharmacogenetic bases of drug responsiveness. The quality of life evaluation in the three groups will be assessed. Statistical evaluation includes an interim analysis at month 24 and conclusive analyses at month 48. The present study will add information about pharmacological therapy in MFS, supporting the new application of angiotensin receptor 1 blockers and finding beta-adrenergic blockers that may give more specific effects. Moreover, the study will further deepen understanding of the pathogenetic mechanisms that are active in Marfan syndrome through the pharmacogenomic and transcriptomic mechanisms that may explain MFS phenotype variability.
Araki, Haruna; Kitamura, Tadashi; Horai, Tetsuya; Shibata, Ko; Miyaji, Kagami
2014-12-01
The elephant trunk technique for aortic dissection is useful for reducing false lumen pressure; however, a folded vascular prosthesis inside the aorta can cause haemolysis. The purpose of this study was to investigate whether an elephant trunk in a small-calibre lumen can cause haemolysis. Inpatient and outpatient records were retrospectively reviewed. Two cases of haemolytic anaemia after aortic surgery using the elephant trunk technique were identified from 2011 to 2013. A 64-year-old man, who underwent graft replacement of the ascending aorta for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta and moderate aortic regurgitation. A two-stage surgery was scheduled. Total arch replacement with an elephant trunk in the true lumen and concomitant aortic valve replacement were performed. Postoperatively, he developed severe haemolytic anaemia because of the folded elephant trunk. The anaemia improved after the second surgery, including graft replacement of the descending aorta. Similarly, a 61-year-old man, who underwent total arch replacement for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta. Graft replacement of the descending aorta with an elephant trunk inserted into the true lumen was performed. The patient postoperatively developed haemolytic anaemia because of the folded elephant trunk, which improved after additional stent grafting into the elephant trunk. A folded elephant trunk in a small-calibre lumen can cause haemolysis. Therefore, inserting an elephant trunk in a small-calibre true lumen during surgery for chronic aortic dissection should be avoided. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Auriemma, Stefano; D'Onofrio, Augusto; Brunelli, Massimo; Magagna, Paolo; Paccanaro, Mariemma; Rulfo, Fanny; Fabbri, Alessandro
2006-09-01
The Edwards Lifesciences Prima Plus stentless valve (ELSV) is a bioprosthesis manufactured from a porcine aortic root. The study aim was to evaluate late clinical outcomes after aortic valve replacement (AVR) with ELSV implanted as a miniroot in patients with aortic valve disease. Between 1993 and 2004, 318 patients (232 males, 86 females; mean age 69 +/- 9 years; range: 37-83 years) underwent AVR with the ELSV. Preoperatively, 102 patients (32%), 162 (51%) and 54 (17%) were in NYHA classes I/II, III and IV, respectively. Aortic stenosis, aortic regurgitation and combined lesions were present in 124 patients (39%), 114 (36%) and 41 (13%), respectively. Twenty patients (6%) were referred for an acute aortic dissection, 20 (6%) for an aortic root aneurysm, and 139 (44%) had an associated aneurysmal dilatation of the ascending aorta. The ascending aorta was replaced in 159 patients (50%); aortic arch replacement was required in 10 (3%). Coronary artery bypass graft was performed in 86 patients (27%). The follow up was based on clinical data. Operative mortality was 5% (n = 17). There were 49 late deaths (5.2%/pt-yr). Valve-related mortality occurred in 10 patients (1%/pt-yr). Actuarial survival at five and 10 years was 78% and 33%, respectively. Actuarial freedom from valve reoperation and structural valve deterioration at 10 years were 100% and 64%. Actuarial freedom from embolic events and endocarditis at 10 years were 84% and 81%, respectively. The ELSV, when implanted as a miniroot, provided good early and long-term results in terms of survival and freedom from major complications.
Winter, Christian; Pfister, David; Busch, Jonas; Bingöl, Cigdem; Ranft, Ulrich; Schrader, Mark; Dieckmann, Klaus-Peter; Heidenreich, Axel; Albers, Peter
2012-02-01
Residual tumor resection (RTR) after chemotherapy in patients with advanced germ cell tumors (GCT) is an important part of the multimodal treatment. To provide a complete resection of residual tumor, additional surgical procedures are sometimes necessary. In particular, additional vascular interventions are high-risk procedures that require multidisciplinary planning and adequate resources to optimize outcome. The aim was to identify parameters that predict additional vascular procedures during RTR in GCT patients. A retrospective analysis was performed in 402 GCT patients who underwent 414 RTRs in 9 German Testicular Cancer Study Group (GTCSG) centers. Overall, 339 of 414 RTRs were evaluable with complete perioperative data sets. The RTR database was queried for additional vascular procedures (inferior vena cava [IVC] interventions, aortic prosthesis) and correlated to International Germ Cell Cancer Collaborative Group (IGCCCG) classification and residual tumor volume. In 40 RTRs, major vascular procedures (23 IVC resections with or without prosthesis, 11 partial IVC resections, and 6 aortic prostheses) were performed. In univariate analysis, the necessity of IVC intervention was significantly correlated with IGCCCG (14.1% intermediate/poor vs 4.8% good; p=0.0047) and residual tumor size (3.7% size < 5 cm vs 17.9% size ≥ 5 cm; p < 0.0001). In multivariate analysis, IVC intervention was significantly associated with residual tumor size ≥ 5 cm (odds ratio [OR]: 4.61; p=0.0007). In a predictive model combining residual tumor size and IGCCCG classification, every fifth patient (20.4%) with a residual tumor size ≥ 5 cm and intermediate or poor prognosis needed an IVC intervention during RTR. The need for an aortic prosthesis showed no correlation to either IGCCCG (p=0.1811) or tumor size (p=0.0651). The necessity for IVC intervention during RTR is correlated to residual tumor size and initial IGCCCG classification. Patients with high-volume residual tumors and intermediate or poor risk features must initially be identified as high-risk patients for vascular procedures and therefore should be referred to specialized surgical centers with the ad hoc possibility of vascular interventions. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Sturla, Francesco; Ronzoni, Mattia; Vitali, Mattia; Dimasi, Annalisa; Vismara, Riccardo; Preston-Maher, Georgia; Burriesci, Gaetano; Votta, Emiliano; Redaelli, Alberto
2016-08-16
Transcatheter aortic valve implantation (TAVI) can treat symptomatic patients with calcific aortic stenosis. However, the severity and distribution of the calcification of valve leaflets can impair the TAVI efficacy. Here we tackle this issue from a biomechanical standpoint, by finite element simulation of a widely adopted balloon-expandable TAVI in three models representing the aortic root with different scenarios of calcific aortic stenosis. We developed a modeling approach realistically accounting for aortic root pressurization and complex anatomy, detailed calcification patterns, and for the actual stent deployment through balloon-expansion. Numerical results highlighted the dependency on the specific calcification pattern of the "dog-boning" of the stent. Also, local stent distortions were associated with leaflet calcifications, and led to localized gaps between the TAVI stent and the aortic tissues, with potential implications in terms of paravalvular leakage. High stresses were found on calcium deposits, which may be a risk factor for stroke; their magnitude and the extent of the affected regions substantially increased for the case of an "arc-shaped" calcification, running from commissure to commissure. Moreover, high stresses due to the interaction between the aortic wall and the leaflet calcifications were computed in the annular region, suggesting an increased risk for annular damage. Our analyses suggest a relation between the alteration of the stresses in the native anatomical components and prosthetic implant with the presence and distribution of relevant calcifications. This alteration is dependent on the patient-specific features of the calcific aortic stenosis and may be a relevant indicator of suboptimal TAVI results. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Extent of Aortic Replacement in Type A Dissection: Current Answers for an Endless Debate.
Waterford, Stephen D; Gardner, Rita L; Moon, Marc R
2018-05-17
The proximal and distal extent of surgery for type A dissection is the subject of this review article. In this report, we summarize select series that illumine the issue at hand and provide insight into the surgical approach at our institution to DeBakey type I aortic dissections. For proximal extent, we discuss preservation of the aortic valve in the presence of aortic insufficiency, as well as management of the aortic root in the setting of root dilation. Distal extent of surgery for type A dissection has been a much more controversial topic. At our institution, we subscribe to the philosophy of ascending or hemiarch replacement alone for dissection under most circumstances. We describe when we believe a more aggressive arch replacement for type A dissection may be considered and detail the reports of other groups that have performed this operation more routinely. We also touch upon the frozen elephant trunk operation and its role in type A dissection, although we believe it should be reserved for high-volume dedicated aortic centers. Finally, we conclude by discussing the role of experience in choosing aortic operations for type A dissection. In our opinion, there is no single correct operation for a patient with type A dissection, but there is a correct operation for each surgeon and clinical scenario. Copyright © 2018. Published by Elsevier Inc.
Transcatheter aortic-valve replacement with a self-expanding prosthesis.
Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K
2014-05-08
We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).
Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.
Reardon, Michael J; Van Mieghem, Nicolas M; Popma, Jeffrey J; Kleiman, Neal S; Søndergaard, Lars; Mumtaz, Mubashir; Adams, David H; Deeb, G Michael; Maini, Brijeshwar; Gada, Hemal; Chetcuti, Stanley; Gleason, Thomas; Heiser, John; Lange, Rüdiger; Merhi, William; Oh, Jae K; Olsen, Peter S; Piazza, Nicolo; Williams, Mathew; Windecker, Stephan; Yakubov, Steven J; Grube, Eberhard; Makkar, Raj; Lee, Joon S; Conte, John; Vang, Eric; Nguyen, Hang; Chang, Yanping; Mugglin, Andrew S; Serruys, Patrick W J C; Kappetein, Arie P
2017-04-06
Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910 .).
Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger
2011-07-01
This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Varadarajan, Padmini; Patel, Reena; Turk, Rami; Kamath, Ashvin R; Sampath, Unnati; Khandhar, Sumit; Pai, Ramdas G
2013-01-01
Severe aortic regurgitation (AR) is caused by a variety of mechanisms, which include the degenerative process, bicuspid aortic valve (BAV), aortic root dilation, endocarditis or a combination of these. Their frequency in a contemporary clinical series, and their impact on survival, are currently unknown. The authors' echocardiographic database between 1993 and 2007 was screened for patients with severe AR, and yielded 756 patients. Detailed chart reviews were performed to acquire clinical and demographic data. Mortality data were obtained from the social security death index and analyzed as a function of the condition's etiology. The probable etiologies for AR were: degenerative in 29% of patients, BAV in 10%, aortic root pathology in 11%, endocarditis in 10%, and mixed or unclear mechanism in 40%. Survival was a function of the etiology (p < 0.0001), with degenerative mechanism having the worst prognosis and BAV the best. This differential impact on mortality remained significant after adjusting for age, gender, coronary artery disease, diabetes mellitus, renal insufficiency, left ventricular ejection fraction and aortic valve replacement, using the Cox regression model (p < 0.0001). Etiology has a significant independent impact on mortality in patients with severe AR, with the worst survival being seen in degenerative AR.
Gao, Linggen; Chen, Lei; Fan, Li; Gao, Dewei; Liang, Zhiru; Wang, Rong; Lu, Wenning
2016-08-15
To assess the effect of losartan therapy on progressive aortic dilatation and on clinical outcome in patients with Marfan's syndrome (MFS). The meta-analysis was instituted, which included studies identified by a systematic review of MEDLINE of peer-reviewed publications. Echocardiogram or MRI measurements of the aortic root dimension and outcome measures of death, cardiovascular surgery and aortic dissection or rupture were compared between patients who were treated and untreated with losartan therapy. Six randomized trials with 1398 subjects met all the inclusion criteria and were included in the meta-analysis. Compared with non-losartan treatment, losartan therapy significantly decreased the rate of aortic dilatation (SMD=-0.13 with 95% CI -0.25 to 0.00, p=0.04). The clinical outcome beneficial was not observed in the losartan treatment group when compared with no losartan treatment group (odds ratio=1.04 with 95% CI of 0.57-1.87). Given the current results of the meta-analysis and together with the lack of associated side effects, it would be reasonable to use losartan in MFS patients with aortic root dilatation. However, no clinical outcome benefits were observed in the losartan treatment group when compared with no losartan treatment group. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Haya, Laura; Tavoularis, Stavros
2017-06-01
Flow characteristics past a bileaflet mechanical heart valve were measured under physiological flow conditions in a straight tube with an axisymmetric expansion, similar to vessels used in previous studies, and in an anatomical model of the aorta. We found that anatomical features, including the three-lobed sinus and the aorta's curvature affected significantly the flow characteristics. The turbulent and viscous stresses were presented and discussed as indicators for potential blood damage and thrombosis. Both types of stresses, averaged over the two axial measurement planes, were significantly lower in the anatomical model than in the axisymmetric one. This difference was attributed to the lower height-to-width ratio and more gradual contraction of the anatomical aortic sinus. The curvature of the aorta caused asymmetries in the velocity and stress distributions during forward flow. Secondary flows resulting from the aorta's curvature are thought to have redistributed the fluid stresses transversely, resulting in a more homogeneous stress distribution in the anatomical aortic root than in the axisymmetric root. The results of this study demonstrate the importance of modelling accurately the aortic geometry in experimental and computational studies of prosthetic devices. Moreover, our findings suggest that grafts used for aortic root replacement should approximate as closely as possible the shape of the natural sinuses.
Cardiovascular operations for Loeys-Dietz syndrome: Intermediate-term results.
Patel, Nishant D; Crawford, Todd; Magruder, J Trent; Alejo, Diane E; Hibino, Narutoshi; Black, James; Dietz, Harry C; Vricella, Luca A; Cameron, Duke E
2017-02-01
Early experience with Loeys-Dietz syndrome (LDS) suggested an aggressive aortopathy with high risk of aneurysm dissection and rupture at young ages and at smaller aortic diameters than in other connective tissue disorders. We reviewed our experience with LDS to re-examine our indications and outcomes of surgical management. We reviewed all patients with a diagnosis of LDS who underwent cardiovascular surgery at our institution. The primary endpoint was mortality, and secondary endpoints included postoperative complications and need for reintervention. Seventy-nine operated patients with LDS were identified. Mean age at first operation was 25 years, 39 (49%) were female, and 38 (48%) were children (age <18 years). Six (8%) patients presented with acute dissection. Five (6%) patients had a bicuspid aortic valve, and all presented with an ascending aortic aneurysm with a mean root diameter of 3.5cm. Twenty (25%) patients had a previous sternotomy. Sixty-five (82%) patients underwent aortic root replacement, of whom 52 underwent a valve-sparing operation and 4 had concomitant arch replacement. Mean aortic root diameter in this group was 4.2 cm. Nine (11%) patients underwent aortic arch replacement, 2 (3%) had isolated ascending aorta replacement, and 3 (4%) underwent open thoracoabdominal repair. There were 2 (3%) operative and 8 late deaths. Nineteen patients underwent subsequent operations for late aneurysm and/or dissection. Mean follow-up was 6 years (range 0-24 years). Kaplan-Meier survival was 88% at 10 years. Growing experience with LDS has confirmed early impressions of its aggressive nature and proclivity toward aortic catastrophe. Surgical outcomes are favorable, but reintervention rates are high. Meticulous follow-up with cardiovascular surveillance imaging remain important for management, particularly as clinical LDS subtypes are characterized and more tailored treatment is developed. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Chen, Mei-Ling; Chen, Michael Y.; Yin, Wei-Hsian; Wei, Jeng; Wang, Ji-Hung
2014-01-01
The Bentall procedure is the gold standard for treating aortic dissection complicated with valvular and ascending aorta disease. Recent results for this procedure have been excellent; nearly 100% of patients remain free of infective endocarditis in long-term follow-up. We report a case of delayed Streptococcus agalactiae infective endocarditis complicated by mycotic aneurysm in a man who had undergone the Bentall procedure with a mechanical valve conduit 15 years previously. The mycotic aneurysm was located in the remnant aortic root, below the mechanical valve conduit, and later ruptured into the right atrium. The patient was treated conservatively and survived the acute period. Later, the aortic root defect was repaired successfully by means of a hybrid technique using a Amplatzer duct occluder. PMID:27122809
Sixteen-Year Experience of David and Bentall Procedures in Acute Type A Aortic Dissection.
Yang, Bo; Patel, Himanshu J; Sorek, Claire; Hornsby, Whitney E; Wu, Xiaoting; Ward, Sarah; Thomas, Marc; Driscoll, Anisa; Waidley, Victoria A; Norton, Elizabeth L; Likosky, Donald S; Deeb, G Michael
2018-03-01
To examine short-term and midterm outcomes after the David and Bentall procedures in patients with an acute type A aortic dissection. Between 2001 and 2017, patients (n = 135) with acute type A aortic dissection underwent an aortic root replacement with either the David (n = 40) or Bentall (n = 95) procedure. Perioperative outcome, reoperation rate, aortic valve function, and long-term survival were evaluated. The median age of the entire cohort was 56 years. Rates of malperfusion (21%), shock (16%), history of renal failure (4%), and extent of surgery were similar between David and Bentall groups. However, the David group was significantly younger (45 versus 61 years) with less hypertension (45% versus 66%), coronary artery disease (0% versus 17%), valvulopathy (5% versus 19%), and prior cardiac surgery (5% versus 21%). Overall operative mortality was 9.6% (David 3% and Bentall 13%). Composite outcome comprising myocardial infarction, stroke, new-onset renal failure, and operative mortality was 18% in the entire cohort (David 5% and Bentall 23%). In the David group, the freedom of moderate aortic insufficiency was 95% at 10 years. The rate of reoperation for pathology of the proximal aorta or aortic valve was 0% and 2% for the David and Bentall groups, respectively. Ten-year Kaplan-Meier survival was 66% (95% confidence interval: 51% to 77%) for the entire cohort, with 98% (95% confidence interval: 84% to 99%) survival in the David group and 57% (95% confidence interval: 42% to 70%) survival in the Bentall group. Both the David and Bentall procedures are appropriate surgical approaches for aortic root replacement in select patients with an acute type A aortic dissection. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Aortic root dilatation in young patients with cryptogenic stroke and patent foramen ovale.
Keenan, Niall G; Brochet, Éric; Juliard, Jean-Michel; Malanca, Mihaela; Aubry, Pierre; Lepage, Laurent; Cueff, Caroline; Jondeau, Guillaume; Iung, Bernard; Vahanian, Alec; Messika-Zeitoun, David
2012-01-01
No previous study has looked for an association between aortic dilatation and the clinical sequelae of patent foramen ovale (PFO), although a possible relationship has been identified in case reports. To compare aortic dimensions in patients with symptomatic PFO and healthy controls. Forty-seven patients were identified who presented with cryptogenic cerebrovascular accident (CVA) assessed as most likely secondary to PFO (confirmed by contrast study), were aged less than 50 years and underwent percutaneous PFO closure. Forty-seven age-, sex- and body surface area-matched healthy controls were also identified. Aortic root diameters were greater in PFO patients. The difference was more marked at the levels of the sinuses of Valsalva (34±4 vs 31±3 mm, P<0.01) and the proximal ascending aorta (32±4 vs 29±3, P<0.01) and more modest at the level of the aortic annulus (23±3 vs 22±2 mm, P=0.20). In addition, patients with massive right-to-left shunting tended to have larger aortic diameters. In contrast, left ventricular end-systolic and end-diastolic diameters were not larger than in controls (30±4 vs 32±5 mm, P=0.10 and 48±5 vs 50±4 mm, P=0.04, respectively). The present study shows that aortic diameter is increased in young patients with cryptogenic CVA and PFO compared with in healthy subjects. Our results suggest that aortic dilatation may potentiate the risk of CVA in PFO patients and support further research in this area. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Belov, Iu V; Stepanenko, A B; Gens, A P; Charchian, E R; Savichev, D D
2007-01-01
Simultaneous surgical interventions on the aorta and valvular system of the heart were performed in four patients presenting with aortic dissections and aneurysms conditioned by Marfan's syndrome. The following reconstructive operations were carried out: 1) prosthetic repair of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries into the side of the prosthesis according to the Benthall - De Bono technique, annuloplasty of the tricuspid valve according to the De Vega technique, valvuloplasty of the mitral valve by the Alferi technique; 2) grafting of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries according to the Kabrol's technique, plasty of the tricuspid valve by the De Vega technique; 3) prosthetic repair of the aortic arch with distal wedge-like excision of the membrane of the dissection and directing the blood flow along the both channels, plasty of the mitral valve, plasty of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side of the graft according to the Benthall - De Bono technique; (4) plasty of the mitral valve with a disk graft through the fibrous ring of the aortic valve, prosthetic repair of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side according to the Benthall-De Bono technique.
Gansera, Laura Sophie; Eszlari, Edgar; Deutsch, Oliver; Eichinger, Walter Benno; Gansera, Brigitte
2016-01-01
To discuss the dilemma of adequate decision making in patients with intravenous drug abuse and recurrent valve prosthesis infections or in patients with positive HIV or hepatitis C status. Ethical, social, and economic considerations, not only in terms of technical feasibility but also in terms of unpromising results and aspects of resources, are discussed. Thoughts are presented about the legitimation of cardiac surgery centers refusing to perform surgery in high-risk patients with HIV or hepatitis C infections. Presentation of six cases for discussion. Three patients were addicted to intravenous drugs and had recurrent prosthetic valve endocarditis, and the other three patients had either paravalvular leakage of a mitral valve prosthesis or acute aortic dissection or coronary artery disease. Five of these patients suffered from HIV/AIDS and infective hepatitis C. Four of these patients were refused by other centers due to high risk or a lack of capacity. All six patients were operated during 2013. Mortality was 17%. Decision making in noncompliant drug addicts with recurrent prosthesis infection and in HIV-positive patients leads beyond surgical challenges to ethical and economic considerations. Georg Thieme Verlag KG Stuttgart · New York.
Sundseth, Jarle; Jacobsen, Eva A; Kolstad, Frode; Nygaard, Oystein P; Zwart, John A; Hol, Per K
2013-10-01
Cervical disc prostheses induce significant amount of artifact in magnetic resonance imaging which may complicate radiologic follow-up after surgery. The purpose of this study was to investigate as to what extent the artifact, induced by the frequently used Discover(®) cervical disc prosthesis, impedes interpretation of the MR images at operated and adjacent levels in 1.5 and 3 Tesla MR. Ten subsequent patients were investigated in both 1.5 and 3 Tesla MR with standard image sequences one year following anterior cervical discectomy with arthroplasty. Two neuroradiologists evaluated the images by consensus. Emphasis was made on signal changes in medulla at all levels and visualization of root canals at operated and adjacent levels. A "blur artifact ratio" was calculated and defined as the height of the artifact on T1 sagittal images related to the operated level. The artifacts induced in 1.5 and 3 Tesla MR were of entirely different character and evaluation of the spinal cord at operated level was impossible in both magnets. Artifacts also made the root canals difficult to assess at operated level and more pronounced in the 3 Tesla MR. At the adjacent levels however, the spinal cord and root canals were completely visualized in all patients. The "blur artifact" induced at operated level was also more pronounced in the 3 Tesla MR. The artifact induced by the Discover(®) titanium disc prosthesis in both 1.5 and 3 Tesla MR, makes interpretation of the spinal cord impossible and visualization of the root canals difficult at operated level. Adjusting the MR sequences to produce the least amount of artifact is important.
Leibundgut, Gregor; Bernheim, Alain M
2010-04-01
The authors report the case of a 77-year-old male patient with sinus rhythm and a first-degree atrioventricular (AV) block who was referred for echocardiographic follow-up 18 years after aortic valve replacement. Left ventricular systolic function as well as the function of the aortic prosthesis was normal. Systolic mitral regurgitation (MR) was virtually absent, but isolated late diastolic MR was detected by colour Doppler imaging. Coincidental to the occurrence of diastolic MR, a second late diastolic forward flow in the pulmonary veins was observed. Therefore, during the prolonged left atrial relaxation caused by first-degree AV block, the left atrial pressure drops below the pressure in both adjacent chambers in late diastole, resulting in both late diastolic MR and a second diastolic pulmonary venous forward flow.
Current role of endovascular therapy in Marfan patients with previous aortic surgery
Akin, Ibrahim; Kische, Stephan; Rehders, Tim C; Chatterjee, Tushar; Schneider, Henrik; Körber, Thomas; Nienaber, Christoph A; Ince, Hüseyin
2008-01-01
The Marfan syndrome is a heritable disorder of the connective tissue which affects the cardiovascular, ocular, and skeletal system. The cardiovascular manifestation with aortic root dilatation, aortic valve regurgitation, and aortic dissection has a prevalence of 60% to 90% and determines the premature death of these patients. Thirty-four percent of the patients with Marfan syndrome will have serious cardiovascular complications requiring surgery in the first 10 years after diagnosis. Before aortic surgery became available, the majority of the patients died by the age of 32 years. Introduction in the aortic surgery techniques caused an increase of the 10 year survival rate up to 97%. The purpose of this article is to give an overview about the feasibility and outcome of stent-graft placement in the descending thoracic aorta in Marfan patients with previous aortic surgery. PMID:18629349
Intravalvular Implantation of Mitral Valve Prostheses
Cooley, Denton A.; Ingram, Michael T.
1987-01-01
We describe a technique of intravalvular implantation of a low-profile prosthesis that has been used in nine patients with mitral valve lesions. This technique preserves the anterior and posterior chordae and papillary mechanisms, which may decrease the incidence of postoperative left ventricular dysfunction that has been noted following standard mitral valve replacement. The technique may also be useful in some patients with aortic and tricuspid regurgitation when the annulus and leaflets are relatively normal pathologically. (Texas Heart Institute Journal 1987;14:188-193) PMID:15229740
Percutaneous re-revalvulation of the tricuspid valve.
Gewillig, Marc; Dubois, Christophe
2011-04-01
We report a successful percutaneous revalvulation of a dysfunctional tricuspid bioprothesis in an 8-year-old child. Five years after implanting a 25-mm Carpentier-Edwards valve in the tricuspid position, the prosthesis showed significant dysfunction with clinical right heart failure. A 26-mm Edwards-Sapien XT inverted aortic valve was successfully implanted through a 19F sheath using a jugular approach. Such procedure can significantly postpone the need for surgical replacement of a biological valve. Copyright © 2011 Wiley-Liss, Inc.
Native valve endocarditis due to Corynebacterium group JK.
Moffie, B G; Veenendaal, R A; Thompson, J
1990-12-01
We report a case of a 32-yr-old woman on chronic intermittent haemodialysis, who developed endocarditis due to a Corynebacterium group JK, involving both the native aortic and mitral valves. Despite a four-week treatment with vancomycin, an aortic root abscess developed. The diagnosis was confirmed on autopsy.
Fisher, E A; Estioko, M R; Stern, E H; Goldman, M E
1987-07-01
Aortic root abscess occurs frequently in aortic prosthetic valve infective endocarditis. The present echocardiographic report documents a ruptured abscess that led to a direct communication between the left ventricular outflow tract and the left atrium confirmed by real-time (color flow) Doppler imaging.
Ferrera, Carlos; Nombela-Franco, Luis; Garcia, Eulogio; Jimenez-Quevedo, Pilar; Biagioni, Corina; Gonzalo, Nieves; Nuñez-Gil, Ivan; Viana-Tejedor, Ana; Salinas, Pablo; Alberto de Agustin, Jose; Almeria, Carlos; Islas, Fabian; Perez de Isla, Leopoldo; Fernandez-Perez, Cristina; Escaned, Javier; Fernández-Ortiz, Antonio; Macaya, Carlos
2017-11-01
To evaluate the safety and midterm hemodynamic results of direct transcatheter aortic valve replacement (TAVR) without pre-implantation balloon aortic valvuloplasty (BAV). BAV was considered a mandatory previous step in TAVR procedures. A total of 339 consecutive patients who underwent transfemoral TAVR were prospectively selected. A 1:1 matching was conducted, pairing age, prosthesis type (self-expandable or balloon expandable) and size, and valve calcification grade (48% with moderate to severe valve calcification). Finally, 102 pairs (102 patients with previous BAV and 102 without BAV) were obtained. Direct TAVR was feasible in all patients without any crossover to BAV group. Device success was achieved in 91.2% and 90.2% of cases in direct TAVR and pre-BAV groups (P = 0.810), respectively, without any differences in balloon postdilation rate and residual aortic regurgitation. The amount of contrast agent, acute kidney injury and myocardial injury was significantly lower in the direct implantation group (P < 0.05). No differences were found in 30-day and 1-year mortality between both groups (4.9% vs. 9.8%, P = 0.177 and 14.0% vs. 23.8%, P = 0.771, respectively). Hemodynamic parameters remained stable after 1-year follow-up in both groups. Direct transfemoral TAVR without prior BAV was safe in patients with calcified severe aortic stenosis. Pre-implantation BAV could be omitted in patients undergoing TAVR, without influence in procedure success rate, and subsequent patients' clinical course and valve hemodynamic performance. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Philip, Femi; Faza, Nadine Nadar; Schoenhagen, Paul; Desai, Milind Y; Tuzcu, E Murat; Svensson, Lars G; Kapadia, Samir R
2015-08-01
Patients with severe aortic stenosis due to BAV are excluded from transcatheter aortic valve replacement (TAVR) due to concern for asymmetric expansion and valve dysfunction. We sought to characterize the aortic root and annulus in bicuspid aortic valve (BAV) and tricuspid aortic valves (TAV). We identified patients with severe AS who underwent multi-detector computed tomographic (MDCT) imaging prior to surgical aortic valve replacement (SAVR, n = 200) for BAV and TAVR (n = 200) for TAV from 2010 to 2013. The presence of a BAV was confirmed on surgical and pathological review. Annulus measurements of the basal ring (short- and long-axis, area-derived diameter), coronary ostia height, sinus area (SA), sino-tubular junction area (STJ), calcification and eccentricity index (EI, 1-short axis/long axis) were made. Patients with TAV were older (78.8 years vs. 57.8 years, P = 0.04) than those with BAV. The aortic annulus area (5.21 ± 2.1 cm(2) vs. 4.63 ± 2.0 cm(2) , P = 0.0001), sinus of Valsalva diameter (3.7 ± 0.9 cm vs. 3.1 ± 0.1 cm, P = 0.001) and ascending aorta diameter (3.5 ± 0.7 cm vs. 2.97 ± 0.6 cm, P = 0.001) were significantly larger with BAV. Bicuspid aortic annuli were significantly less elliptical (EI, 1.24 ± 0.1 vs. 1.29 ± 0.1, P = 0.006) and more circular (39% vs. 4%, P < 0.001) compared to the TAV annulus. There was more eccentric annular calcification in BAV vs. TAV (68% vs. 32%, P < 0.001). The mean distance from the aortic annulus to the left main coronary ostium was less than the right coronary ostium. Less than 10% of the BAV annuli would not fit a currently available valved stents. Bicuspid aortic valves have a larger annulus size, sinus of Valsalva and ascending aorta dimensions. In addition, the BAV aortic annuli appear circular and most will fit currently available commercial valved stents. © 2015 Wiley Periodicals, Inc.
Dinges, Christian; Steindl, Johannes; Hitzl, Wolfgang; Kiesslich, Tobias; Seitelberger, Rainald
2018-06-01
evidence-based medicine (EBM) approaches have reached broad acceptance, both in conservative and surgical disciplines. The aim of this study is to clarify the role of EBM in a rare condition of aortic regurgitation (AR) with surgical indication. A purpose-built Internet-based questionnaire was sent to 607 cardiovascular surgeons in Germany, Austria, and Switzerland. A virtual 64-year-old patient's medical history was presented, including two ultrasound images and one computed tomography scan, showing a 58-mm aortic root aneurysm and a severe trileaflet regurgitant aortic valve. Participants had to choose their preferred therapeutic strategy from a list. Additionally, demographics including nationality, the center size, and the frequency of similar types of patients referred to their departments were collected. Of 607 questionnaires, 100 were returned (16%). One participant was excluded due to conflicting answers. Most surgeons ( n = 84; 84%) chose a valve-sparing root replacement (VSRR). A Bentall procedure was preferred by 13 surgeons (13%). Two surgeons voted for aortic valve replacement combined with partial root resection. The decision-making process was not significantly influenced by center size, nationality, or frequency of patients. Applying the current guidelines to our virtual study patient, 84% of participants acted accordingly choosing VSRR. Remarkably, 14% of these surgeons see less than 10 and 43% see not more than 20 comparable patients per year. Since the guidelines reserve VSRR for competent centers, those numbers as well as the guidelines themselves should be further discussed. Georg Thieme Verlag KG Stuttgart · New York.
Beneficial Outcome of Losartan Therapy Depends on Type of FBN1 Mutation in Marfan Syndrome.
Franken, Romy; den Hartog, Alexander W; Radonic, Teodora; Micha, Dimitra; Maugeri, Alessandra; van Dijk, Fleur S; Meijers-Heijboer, Hanne E; Timmermans, Janneke; Scholte, Arthur J; van den Berg, Maarten P; Groenink, Maarten; Mulder, Barbara J M; Zwinderman, Aeilko H; de Waard, Vivian; Pals, Gerard
2015-04-01
It has been shown that losartan reduces aortic dilatation in patients with Marfan syndrome. However, treatment response is highly variable. This study investigates losartan effectiveness in genetically classified subgroups. In this predefined substudy of COMPARE, Marfan patients were randomized to daily receive losartan 100 mg or no losartan. Aortic root dimensions were measured by MRI at baseline and after 3 years. FBN1 mutations were classified based on fibrillin-1 protein effect into (1) haploinsufficiency, decreased amount of normal fibrillin-1, or (2) dominant negative, normal fibrillin-1 abundance with mutant fibrillin-1 incorporated in the matrix. A pathogenic FBN1 mutation was found in 117 patients, of whom 79 patients were positive for a dominant negative mutation (67.5%) and 38 for a mutation causing haploinsufficiency (32.5%). Baseline characteristics between treatment groups were similar. Overall, losartan significantly reduced aortic root dilatation rate (no losartan, 1.3±1.5 mm/3 years, n=59 versus losartan, 0.8±1.4 mm/3 years, n=58; P=0.009). However, losartan reduced only aortic root dilatation rate in haploinsufficient patients (no losartan, 1.8±1.5 mm/3 years, n=21 versus losartan 0.5±0.8 mm/3 years, n=17; P=0.001) and not in dominant negative patients (no losartan, 1.2±1.7 mm/3 years, n=38 versus losartan 0.8±1.3 mm/3 years, n=41; P=0.197). Marfan patients with haploinsufficient FBN1 mutations seem to be more responsive to losartan therapy for inhibition of aortic root dilatation rate compared with dominant negative patients. Additional treatment strategies are needed in Marfan patients with dominant negative FBN1 mutations. http://www.trialregister.nl/trialreg/index.asp; Unique Identifier: NTR1423. © 2015 American Heart Association, Inc.
Low contrast media volume in pre-TAVI CT examinations.
Kok, Madeleine; Turek, Jakub; Mihl, Casper; Reinartz, Sebastian D; Gohmann, Robin F; Nijssen, Estelle C; Kats, Suzanne; van Ommen, Vincent G; Kietselaer, Bas L J H; Wildberger, Joachim E; Das, Marco
2016-08-01
To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU ± SD) at the aortic root (helical) were: group 1: 381 ± 65HU and 13 ± 8; group 2: 442 ± 68HU and 10 ± 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 ± 117HU and 11 ± 6; group 2: 389 ± 102HU and 13 ± 6. CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. • Image quality could be maintained using low kVp scan protocols. • Low kVp protocols reduce contrast media volume by 34-67 %. • Less contrast media volume lowers the risk of contrast-induced nephropathy.
Liu, Lulu; Qin, Chaoyi; Hou, Jianglong; Zhu, Da; Zhang, Bengui; Ma, Hao
2016-01-01
Acute Stanford type A aortic dissection requires an extremely complex surgical strategy and presents high risk of complications. Although many different procedures were reported to treat this aortic dissection, high mortality rate and incidences of complications still exist. This study presents a 59-year-old lady with acute Stanford type A aortic dissection, which originated from the aortic root to proximal part of right external iliac artery and involved the brachiocephalic trunk, left carotid artery, celiac trunk, and left renal artery. The patient underwent one-stage hybrid surgery of David procedures, debranching, and endovascular aortic repair under ultrasound-guided aortic arch cannulation cardiopulmonary bypass (CPB). The surgery was successfully performed, and the patient showed no post-operative complication. The one-staged hybrid surgery of David procedures, debranching, and endovascular aortic repair provides novel and well-designed combined techniques for treating complex acute Stanford type A aortic dissection. Our techniques significantly lowered the risks, thereby expanding the indications of surgical intervention for acute Stanford type A aortic dissection. PMID:28149590
Liu, Lulu; Qin, Chaoyi; Hou, Jianglong; Zhu, Da; Zhang, Bengui; Ma, Hao; Guo, Yingqiang
2016-12-01
Acute Stanford type A aortic dissection requires an extremely complex surgical strategy and presents high risk of complications. Although many different procedures were reported to treat this aortic dissection, high mortality rate and incidences of complications still exist. This study presents a 59-year-old lady with acute Stanford type A aortic dissection, which originated from the aortic root to proximal part of right external iliac artery and involved the brachiocephalic trunk, left carotid artery, celiac trunk, and left renal artery. The patient underwent one-stage hybrid surgery of David procedures, debranching, and endovascular aortic repair under ultrasound-guided aortic arch cannulation cardiopulmonary bypass (CPB). The surgery was successfully performed, and the patient showed no post-operative complication. The one-staged hybrid surgery of David procedures, debranching, and endovascular aortic repair provides novel and well-designed combined techniques for treating complex acute Stanford type A aortic dissection. Our techniques significantly lowered the risks, thereby expanding the indications of surgical intervention for acute Stanford type A aortic dissection.
3D Bioprinting of Heterogeneous Aortic Valve Conduits with Alginate/Gelatin Hydrogels
Duan, Bin; Hockaday, Laura A.; Kang, Kevin H.; Butcher, Jonathan T.
2013-01-01
Heart valve disease is a serious and growing public health problem for which prosthetic replacement is most commonly indicated. Current prosthetic devices are inadequate for younger adults and growing children. Tissue engineered living aortic valve conduits have potential for remodeling, regeneration, and growth, but fabricating natural anatomical complexity with cellular heterogeneity remain challenging. In the current study, we implement 3D bioprinting to fabricate living alginate/gelatin hydrogel valve conduits with anatomical architecture and direct incorporation of dual cell types in a regionally constrained manner. Encapsulated aortic root sinus smooth muscle cells (SMC) and aortic valve leaflet interstitial cells (VIC) were viable within alginate/gelatin hydrogel discs over 7 days in culture. Acellular 3D printed hydrogels exhibited reduced modulus, ultimate strength, and peak strain reducing slightly over 7-day culture, while the tensile biomechanics of cell-laden hydrogels were maintained. Aortic valve conduits were successfully bioprinted with direct encapsulation of SMC in the valve root and VIC in the leaflets. Both cell types were viable (81.4±3.4% for SMC and 83.2±4.0% for VIC) within 3D printed tissues. Encapsulated SMC expressed elevated alpha-smooth muscle actin when printed in stiff matrix, while VIC expressed elevated vimentin in soft matrix. These results demonstrate that anatomically complex, heterogeneously encapsulated aortic valve hydrogel conduits can be fabricated with 3D bioprinting. PMID:23015540
Thaden, Jeremy J; Nkomo, Vuyisile T; Lee, Kwang Je; Oh, Jae K
2015-07-01
Although the highest aortic valve velocity was thought to be obtained from imaging windows other than the apex in about 20% of patients with severe aortic stenosis (AS), its occurrence appears to be increasing as the age of patients has increased with the application of transcatheter aortic valve replacement. The aim of this study was to determine the frequency with which the highest peak jet velocity (Vmax) is found at each imaging window, the degree to which neglecting nonapical imaging windows underestimates AS severity, and factors influencing the location of the optimal imaging window in contemporary patients. Echocardiograms obtained in 100 consecutive patients with severe AS from January 3 to May 23, 2012, in which all imaging windows were interrogated, were retrospectively analyzed. AS severity (aortic valve area and mean gradient) was calculated on the basis of the apical imaging window alone and the imaging window with the highest peak jet velocity. The left ventricular-aortic root angle measured in the parasternal long-axis view as well as clinical variables were correlated with the location of highest peak jet velocity. Vmax was most frequently obtained in the right parasternal window (50%), followed by the apex (39%). Subjects with acute angulation more commonly had Vmax at the right parasternal window (65% vs 43%, P = .05) and less commonly had Vmax at the apical window (19% vs 48%, P = .005), but Vmax was still located outside the apical imaging window in 52% of patients with obtuse aortic root angles. If nonapical windows were neglected, 8% of patients (eight of 100) were misclassified from high-gradient severe AS to low-gradient severe AS, and another 15% (15 of 100) with severe AS (aortic valve area < 1.0 cm(2)) were misclassified as having moderate AS (aortic valve area > 1.0 cm(2)). In this contemporary cohort, Vmax was located outside the apical imaging window in 61% of patients, and neglecting the nonapical imaging windows resulted in the misclassification of AS severity in 23% of patients. Aortic root angulation as measured by two-dimensional echocardiography influences the location of Vmax modestly. Despite increasing time constraints on many echocardiography laboratories, these data confirm that routine Doppler interrogation from multiple imaging windows is critical to accurately determine the severity of AS in contemporary clinical practice. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Turbulence downstream of subcoronary stentless and stented aortic valves.
Funder, Jonas Amstrup; Frost, Markus Winther; Wierup, Per; Klaaborg, Kaj-Erik; Hjortdal, Vibeke; Nygaard, Hans; Hasenkam, J Michael
2011-08-11
Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses. Copyright © 2011 Elsevier Ltd. All rights reserved.
Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves
Bazan, Ovandir; Ortiz, Jayme Pinto; Vieira Junior, Francisco Ubaldo; Vieira, Reinaldo Wilson; Antunes, Nilson; Tabacow, Fabio Bittencourt Dutra; Costa, Eduardo Tavares; Petrucci Junior, Orlando
2013-01-01
Introduction In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. Objective To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. Methods To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. ) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. Results It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. Conclusions Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves. PMID:24598950
Kayashima, Yukako; Makhanova, Natalia A.; Matsuki, Kota; Tomita, Hirofumi; Bennett, Brian J.; Maeda, Nobuyo
2015-01-01
The genetic background of apolipoprotein E (apoE) deficient mice influences atherosclerotic plaque development. We previously reported three quantitative trait loci (QTL), Aath1–Aath3, that affect aortic arch atherosclerosis independently of those in the aortic root in a cross between C57BL6 apoEKO mice (B6-apoE) and 129S6 apoEKO mice (129-apoE). To gain further insight into genetic factors that influence atherosclerosis at different vascular locations, we analyzed 335 F2 mice from an intercross between 129-apoE and apoEKO mice on a DBA/2J genetic background (DBA-apoE). The extent of atherosclerosis in the aortic arch was very similar in the two parental strains. Nevertheless, a genome-wide scan identified two significant QTL for plaque size in the aortic arch: Aath4 on Chromosome (Chr) 2 at 137 Mb and Aath5 on Chr 10 at 51 Mb. The DBA alleles of Aath4 and Aath5 respectively confer susceptibility and resistance to aortic arch atherosclerosis over 129 alleles. Both QTL are also independent of those affecting plaque size at the aortic root. Genome analysis suggests that athero-susceptibility of Aath4 in DBA may be contributed by multiple genes, including Mertk and Cd93, that play roles in phagocytosis of apoptotic cells and modulate inflammation. A candidate gene for Aath5 is Stab2, the DBA allele of which is associated with 10 times higher plasma hyaluronan than the 129 allele. Overall, our identification of two new QTL that affect atherosclerosis in an aortic arch-specific manner further supports the involvement of distinct pathological processes at different vascular locations. PMID:25689165
Herren, T; Middendorp, M A; Zbinden, R
2016-04-29
The isolation of Propionibacterium acnes in blood cultures is often considered a contaminant. On rare occasions, P. acnes can cause severe infections, including endocarditis and intravascular prosthesis-associated infections. To evaluate the discrimination between a contaminant and a clinically relevant infection we used an Ouchterlony test system to quantify the antibody response to P. acnes in a patient with a proven P. acnes endocarditis. We report on a 64-year-old Caucasian man who developed P. acnes endocarditis four years following a composite valve-graft conduit replacement of the aortic root. Bacterial growth in blood cultures was detected after an incubation period of 6 days. However, the antibody titer to P. acnes was 1:8 at the time of diagnosis and declined slowly thereafter over 2½ years. The patient's response to the antibiotic treatment was excellent, and no surgical re-intervention was necessary. The working hypothesis of infective endocarditis can be substantiated by serologic testing, which, if positive, provides one additional minor criterion. Moreover, quantification of the antibody response to P. acnes, though not specific, may assist in the differentiation between contaminants and an infection. This quantification may have implications for the patient management, e.g. indication for and choice of the antibiotic therapy.
Triple valve surgery: a 25-year experience.
Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen
2004-09-01
Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become encouraging with improvements in surgical techniques and myocardial preservation methods.
Leaflet escape in a new bileaflet mechanical valve: TRI technologies.
Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino
2003-05-13
Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.
Alternative causes of bioreaction to prosthetic heart valves: three cases with pannus formation.
Karakoyun, Süleyman; Gürsoy, Ozan Mustafa; Kalçık, Macit; Coban Kökten, Sermin; Ozkan, Mehmet
2014-01-01
Pannus formation is an infrequent but serious complication of prosthetic heart valve surgery. The cause of pannus is recognized as a bioreaction to the prostheses; histological investigations have shown that pannus comprises collagen and elastic tissues containing endothelial cells, chronic inflammatory cells, and myofibroblasts. However, the detailed mechanism of its formation has not been fully demonstrated. We aimed to evaluate the potential role of vascular endothelial growth factor (VEGF) and matrix metalloproteinase-2 (MMP-2) in the pathogenesis of pannus formation in three patients with mechanical prosthetic heart valves. Pannus specimens removed from the prostheses were fixed in 10% neutral-buffered formalin for 24 hours after surgical removal and paraffin-embedded using standard procedures. Serial sections were cut at 4 µm for immunohistochemistry analysis. Hematoxylin and eosin (HE) was used in the histological analysis. VEGF and MMP-2 were studied in the immunohistochemistry analysis. Three patients with mechanical prosthetic obstruction due to pannus overgrowth underwent redo valve surgery. In the first and second patients, the mitral prosthesis was explanted along with the pannus overgrowth. The third patient had both aortic and mitral prostheses; the aortic prosthesis was explanted with obstructive pannus formation, whereas the mitral valve was spared with excision of the nonobstructive pannus. The immunohistochemical study demonstrated the expressions of MMP-2 and VEGF in all of the pannus specimens acquired from these cases. VEGF and MMP-2 may play a role in the mechanism of pannus formation as the elements of the chronic active inflammatory process.
Ren, X S; Yu, Y T; Liu, K; Hou, Z H; Gao, Y; Yin, W H; Lyu, B
2017-06-24
Objective: To compare the characteristics of aortic valve dysfunction and ascending aorta dimension in patients with different bicuspid aortic valve (BAV) morphology. Methods: A total of 197 patients who underwent aortic valve replacement between April 2014 and March 2015 and were diagnosed with BAV by pathology were included, and their clinical data were retrospectively analyzed. Patients were divided into raphe(+) group(109 cases) and raphe(-) group(88 cases) according to the presence or absence of raphe, and L-R group(fusion of left and right cusp, 125 cases) and L/R-N group(fusion of left or right and noncoronary cusp, 72 cases) according to fusion type of the cusps. The characteristics of aortic valve dysfunction and ascending aorta dimension in patients with different BAV morphology were compared. Results: (1) Aortic stenosis incidence was lower in raphe(+) group than in raphe(-) group(22.9%(25/109) vs. 69.3%(61/88), P <0.001). Aortic regurgitation incidence was higher in raphe(+) group than in raphe(-) group (61.5%(67/109) vs. 22.7%(20/88), P <0.001). Incidence of type 1 of aortic root dilation was higher in raphe(+) group than in raphe(-) group (23.9%(26/109)vs.10.2%(9/88), P =0.024). (2) Aortic stenosis incidence was lower in L-R group than in L/R-N group(29.6%(37/125) vs. 68.1%(49/72), P <0.001). Aortic regurgitation incidence was higher in L-R group than in L/R-N group (59.2%(74/125) vs. 18.1%(13/72), P <0.001). Incidence of type 3 of aortic root dilation was lower in L-R group than in L/R-N group(10.4%(13/125) vs. 37.5%(27/72), P =0.006). (3) Aortic stenosis incidence was lower in L-R patients than in L/R-N patients(15.1%(13/86)vs. 52.2%(12/23), P =0.001), and aortic regurgitation incidence was higher in L-R patients than in L/R-N patients in raphe(+) group(73.3%(63/86)vs. 17.4%(4/23), P <0.001). Conclusion: There is significant difference in the type of valvular dysfunction and ascending aorta dilatation in patients with different morphological characteristics of BAV.
Pulerwitz, Todd C.; Khalique, Omar K.; Nazif, Tamim N.; Rozenshtein, Anna; Pearson, Gregory D.N.; Hahn, Rebecca T.; Vahl, Torsten P.; Kodali, Susheel K.; George, Isaac; Leon, Martin B.; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J.
2016-01-01
Background Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. Methods 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30mL/min) who underwent a novel VLCV protocol (20mL of iohexol at 2.5mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. Results VLCV patients had mean(±SD) age 86±6.5, BMI 23.9±3.4 kg/m2 with 54% men; SCV patients age 83±8.8, BMI 28.7±5.3 kg/m2, 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. Conclusions This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. PMID:27061253
Durability of Aortic Valve Cusp Repair With and Without Annular Support.
Zeeshan, Ahmad; Idrees, Jay J; Johnston, Douglas R; Rajeswaran, Jeevanantham; Roselli, Eric E; Soltesz, Edward G; Gillinov, A Marc; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Pettersson, Gösta B; Blackstone, Eugene H; Sabik, Joseph F; Svensson, Lars G
2018-03-01
To determine the value of aortic valve repair rather than replacement for valve dysfunction, we assessed late outcomes of various repair techniques in the contemporary era. From January 2001 to January 2011, aortic valve repair was planned in 1,124 patients. Techniques involved commissural figure-of-8 suspension sutures (n = 63 [6.2%]), cusp repair with commissuroplasty (n = 481 [48%]), debridement (n = 174 [17%]), free-margin plication (n = 271 [27%]) or resection (n = 75) or both, or annulus repair with resuspension (n = 230 [23%]), root reimplantation (n = 252 [25%]), or remodeling (n = 35 [3.5%]). Planned repair was aborted for replacement in 115 patients (10%); risk factors included greater severity of aortic regurgitation (AR; p = 0.0002) and valve calcification (p < 0.0001). In-hospital outcomes for the remaining 1,009 patients included death (12 [1.2%]), stroke (13 [1.3%]), and reoperation for valve dysfunction (14 [1.4%]). Freedom from aortic valve reoperation at 1, 5, and 10 years was 97%, 93%, and 90%, respectively. Figure-of-8 suspension sutures, valve resuspension, and root repair and replacement were least likely to require reoperation; cusp repair with commissural sutures, plication, and commissuroplasty was most likely (p < 0.05). Survival at 1, 5, and 10 years was 96%, 92%, and 83%. Immediate postoperative AR grade was none-mild (94%), moderate (5%), and severe (1%). At 10 years after repair, AR grade was none (20%), mild (33%), moderate (26%), and severe (21%). Patients undergoing root procedures were less likely to have higher-grade postoperative AR (p < 0.0001). Valve repair is effective and durable for treating aortic valve dysfunction. Greater severity of AR preoperatively is associated with higher likelihood of repair failure. Commissural figure-of-8 suspension sutures and repair with annular support have the best long-term durability. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
A laboratory model of the aortic root flow including the coronary arteries
NASA Astrophysics Data System (ADS)
Querzoli, Giorgio; Fortini, Stefania; Espa, Stefania; Melchionna, Simone
2016-08-01
Cardiovascular flows have been extensively investigated by means of in vitro models to assess the prosthetic valve performances and to provide insight into the fluid dynamics of the heart and proximal aorta. In particular, the models for the study of the flow past the aortic valve have been continuously improved by including, among other things, the compliance of the vessel and more realistic geometries. The flow within the sinuses of Valsalva is known to play a fundamental role in the dynamics of the aortic valve since they host a recirculation region that interacts with the leaflets. The coronary arteries originate from the ostia located within two of the three sinuses, and their presence may significantly affect the fluid dynamics of the aortic root. In spite of their importance, to the extent of the authors' knowledge, coronary arteries were not included so far when modeling in vitro the transvalvular aortic flow. We present a pulse duplicator consisting of a passively pulsing ventricle, a compliant proximal aorta, and coronary arteries connected to the sinuses of Valsalva. The coronary flow is modulated by a self-regulating device mimicking the physiological mechanism, which is based on the contraction and relaxation of the heart muscle during the cardiac cycle. Results show that the model reproduces satisfyingly the coronary flow. The analysis of the time evolution of the velocity and vorticity fields within the aortic root reveals the main characteristics of the backflow generated through the aorta in order to feed the coronaries during the diastole. Experiments without coronary flow have been run for comparison. Interestingly, the lifetime of the vortex forming in the sinus of Valsalva during the systole is reduced by the presence of the coronaries. As a matter of fact, at the end of the systole, that vortex is washed out because of the suction generated by the coronary flow. Correspondingly, the valve closure is delayed and faster compared to the case with no coronary flow.
García-Martín, Ana; Lázaro-Rivera, Carla; Fernández-Golfín, Covadonga; Salido-Tahoces, Luisa; Moya-Mur, Jose-Luis; Jiménez-Nacher, Jose-Julio; Casas-Rojo, Eduardo; Aquila, Iolanda; González-Gómez, Ariana; Hernández-Antolín, Rosana; Zamorano, José Luis
2016-07-01
A specialized three-dimensional transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced; the system automatically configures a geometric model of the aortic root from the images obtained by 3D-TOE and performs quantitative analysis of these structures. The aim of this study was to compare the measurements of the aortic annulus (AA) obtained by the new model to that obtained by 3D-TOE and multidetector computed tomography (MDCT) in candidates to transcatheter aortic valve implantation (TAVI) and to assess the reproducibility of this new method. We included 31 patients who underwent TAVI. The AA diameters and area were evaluated by the manual 3D-TOE method and by the automatic software. We showed an excellent correlation between the measurements obtained by both methods: intra-class correlation coefficient (ICC): 0.731 (0.508-0.862), r: 0.742 for AA diameter and ICC: 0.723 (0.662-0.923), r: 0.723 for the AA area, with no significant differences regardless of the method used. The interobserver variability was superior for the automatic measurements than for the manual ones. In a subgroup of 10 patients, we also found an excellent correlation between the automatic measurements and those obtained by MDCT, ICC: 0.941 (0.761-0.985), r: 0.901 for AA diameter and ICC: 0.853 (0.409-0.964), r: 0.744 for the AA area. The new automatic 3D-TOE software allows modelling and quantifying the aortic root from 3D-TOE data with high reproducibility. There is good correlation between the automated measurements and other 3D validated techniques. Our results support its use in clinical practice as an alternative to MDCT previous to TAVI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
de Simone, Giovanni; Roman, Mary J; De Marco, Marina; Bella, Jonathan N; Izzo, Raffaele; Lee, Elisa T; Devereux, Richard B
2015-09-28
We evaluated the relationship of aortic root dimension (ARD) with flow output and both peripheral and central blood pressure, using multivariable equations predicting ideal sex-specific ARD at a given age and body height. We measured echocardiographic diastolic ARD at the sinuses of Valsalva in 3160 adults (aged 42±16 years, 61% women) from the fourth examination of the Strong Heart Study who were free of prevalent coronary heart disease, and we compared measured data with the theoretical predicted value to calculate a z score. Central blood pressure was estimated by applanation tonometry of the radial artery in 2319 participants. ARD z scores were divided into tertiles representing small, normal, and large ARD. Participants with large ARD exhibited greater prevalence of central obesity and higher levels of inflammatory markers and lipids (0.05
2012-01-01
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790
Darwazah, Ahmad K
2012-06-29
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.
Glaser, Natalie; Jackson, Veronica; Franco-Cereceda, Anders; Sartipy, Ulrik
2018-05-17
Bovine and porcine bioprostheses are commonly used for surgical aortic valve replacement. It is unknown if the long-term survival differs between the two valve types.We performed a systematic review and meta-analysis to compare survival in patients who underwent aortic valve replacement and received a bovine or a porcine prosthesis. We performed a systematic search of Medline, Embase, Web of Science, and the Cochrane Library. Cohort studies that compared survival between patients who underwent aortic valve replacement and received either a bovine or a porcine bioprosthesis and that reported overall long-term survival with hazard ratio (HR) and 95% confidence interval (CI) were included. Two authors independently reviewed articles considered for inclusion, extracted the information from each study, and performed the quality assessment. We performed a meta-analysis using a random effects model to calculate the pooled HR (95% CI) for all-cause mortality. We did sensitivity analyses to assess the robustness of our findings. Seven studies published between 2010 and 2015 were included, and the combined study population was 49,190 patients. Of these, 32,235 (66%) received a bovine, and 16,955 (34%) received a porcine bioprosthesis. There was no significant difference in all-cause mortality between patients who received a bovine compared with a porcine bioprosthesis (pooled HR 1.00, 95% CI: 0.92-1.09). Heterogeneity between studies was moderate (55.8%, p = 0.04). This systematic review and meta-analysis suggest no difference in survival between patients who received a bovine versus a porcine bioprosthesis after aortic valve replacement. Our study provides valuable evidence for the continuing use of both bovine and porcine bioprosthetic valves for surgical aortic valve replacement. Georg Thieme Verlag KG Stuttgart · New York.
Disc erosion in Models 103 and 104 of Beall mitral valve prostheses
Gómez, Ricardo; Verduras, María José; Lopez-Quintana, Alfonso; Riera, Luis; Zerolo, Ignacio; Martinez-Bordiu, Cristóbal
1981-01-01
Three cases of severe disc variance and erosion of the Teflon-disc Beall mitral valve prosthesis (Models 103 and 104) are reported. In two patients, the Beall mitral valves were excised and replaced with two Björk-Shiley mitral valves. The remaining patient did not survive, and at autopsy, the lens was found at the aortic bifurcation level. Because of this potentially lethal complication, careful follow-up of patients with Beall mitral valve prostheses (Models 103 and 104) is recommended. Images PMID:15216211
Del Trigo, María; Dahou, Abdellaziz; Webb, John G; Dvir, Danny; Puri, Rishi; Abdul-Jawad Altisent, Omar; Campelo-Parada, Francisco; Thompson, Chris; Leipsic, Jonathon; Stub, Dion; DeLarochellière, Robert; Paradis, Jean-Michel; Dumont, Eric; Doyle, Daniel; Mohammadi, Siamak; Pasian, Sergio; Côté, Melanie; Pibarot, Philippe; Rodés-Cabau, Josep
2016-05-01
The self-expanding Portico valve is a new transcatheter aortic valve system yielding promising preliminary results, yet there are no comparative data against earlier generation transcatheter aortic valve systems. The aim of this study was to compare the hemodynamic performance of the Portico and balloon-expandable SAPIEN XT valves in a case-matched study with echocardiographic core laboratory analysis. Twenty-two patients underwent transcatheter aortic valve implantation with the Portico 23-mm valve and were matched for aortic annulus area and mean diameter measured by multidetector computed tomography, left ventricular ejection fraction, body surface area, and body mass index with 40 patients treated with the 23-mm SAPIEN XT. Mean aortic annulus diameters were 19.6±1.3mm by transthoracic echocardiography and 21.4±1.2mm by computed tomography, with no significant between-group differences. Doppler echocardiographic images were collected at baseline and at 1-month of follow-up and were analyzed in a central echocardiography core laboratory. There were no significant between-group differences in residual mean transaortic gradients (SAPIEN XT: 10.4±3.7mmHg; Portico: 9.8±1.1mmHg; P=.49) and effective orifice areas (SAPIEN XT: 1.36±0.27cm(2); Portico, 1.37±.29cm(2); P=.54). Rates of severe prosthesis-patient mismatch (effective orifice area<0.65cm(2)/m(2)) were similar (SAPIEN XT: 13.5%; Portico: 10.0%; P=.56). No between-group differences were found in the occurrence of moderate-severe paravalvular leaks (5.0% vs 4.8% of SAPIEN XT and Portico respectively; P=.90). Transcatheter aortic valve implantation with the self-expanding Portico system yielded similar short-term hemodynamic performance compared with the balloon-expandable SAPIEN XT system for treating patients with severe aortic stenosis and small annuli. Further prospective studies with longer-term follow-up and in patients with larger aortic annuli are required. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Gorham disease of the lumbar spine with an abdominal aortic aneurysm: a case report.
Kakuta, Yohei; Iizuka, Haku; Kobayashi, Ryoichi; Iizuka, Yoichi; Takahashi, Toru; Mohara, Jun; Takagishi, Kenji
2014-01-01
Reports of Gorham disease of the lumbar spine complicated by abdominal aortic aneurysms are rare. We herein report the case of a patient with Gorham disease of the lumber spine involving an abdominal aortic aneurysm (AAA). Case report. A 49-year-old man had a 1-month history of right leg pain and severe low back pain. Plain lumbar radiography revealed an osteolytic lesion in the L4 vertebral body. Computed tomography images demonstrated the presence of an extensive osteolytic lesion in the L4 vertebral body and an AAA in front of the L4 vertebral body. The patient underwent mass resection, spinal reconstruction, and blood vessel prosthesis implantation. During surgery, it was found that the wall of the aorta had completely disappeared and was shielded by the tumor mass; therefore, we speculated that the mass in the lumbar spine had directly invaded the aorta. The patient was able to walk without right leg or low back pain 1 year after undergoing surgery. No recurrence was demonstrated in the magnetic resonance images taken 1 year and 10 months after surgery. Copyright © 2014 Elsevier Inc. All rights reserved.
Evolution of surgical therapy for Stanford acute type A aortic dissection
Chiu, Peter
2016-01-01
Acute type A aortic dissection (AcA-AoD) is a surgical emergency associated with very high morbidity and mortality. Unfortunately, the early outcome of emergency surgical repair has not improved substantially over the last 20 years. Many of the same debates occur repeatedly regarding operative extent and optimal conduct of the operation. The question remains: are patients suffering from too large an operation or too small? The pendulum favoring routine aortic valve resuspension, when feasible, has swung towards frequent aortic root replacement. This already aggressive approach is now being challenged with the even more extensive valve-sparing aortic root replacement (V-SARR) in selected patients. Distally, open replacement of most of the transverse arch is best in most patients. The need for late aortic re-intervention has not been shown to be affected by more extensive distal operative procedures, but the contemporary enthusiasm for a distal frozen elephant trunk (FET) only seems to build. It must be remembered that the first and foremost goal of the operation is to have an operative survivor; additional measures to reduce late morbidity are secondary aspirations. With increasing experience, true contraindications to emergency surgical operation have dwindled, but patients with advanced age, multiple comorbidities, and major neurological deficits do not fare well. The endovascular revolution, moreover, has spawned innovative options for modern practice, including ascending stent graft and adaptations of the old flap fenestration technique. Despite the increasingly complex operations and ever expanding therapies, this life-threatening disease remains a stubborn challenge for all cardiovascular surgeons. Development of specialized thoracic aortic teams and regionalization of care for patients with AcA-AoD offers the most promise to improve overall results. PMID:27563541
Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.
Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René
2017-06-01
Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.
Adrie, Christophe; Parlato, Marianna; Salmi, Lynda; Adib-Conquy, Minou; Bical, Olivier; Deleuze, Philippe; Fitting, Catherine; Cavaillon, Jean Marc; Monchi, Mehran
2015-01-01
To determine whether the good safety profile of transarterial aortic valve implantation (TAVI) is related to lower levels of systemic bacterial translocation and systemic inflammation compared with open-heart surgery. Transcatheter aortic valve implantation via the transfemoral approach is increasingly used in very high-risk patients with aortic stenosis. The outcomes seem similar to those after open-heart aortic valve replacement (OHAVR). Each of 26 consecutive high-risk patients (EuroSCORE >20% for risk of operative death) who underwent TAVI (cases) was matched to the first low-risk patient treated next in our department using elective OHAVR without coronary artery bypass (control subjects). We collected severity, outcome, and echocardiography indicators before and after surgery; complications; proinflammatory cytokine levels; and markers for microbial translocation. Despite greater illness severity, the TAVI patients had significantly lower vasopressor agent requirements, lower delirium rates, shorter hospital stays, and better hemodynamic findings compared with OHAVR patients. Vascular complications were more common after TAVI than after OHAVR (12, with seven requiring interventional therapy vs. 0, P = 0.006). Patients who underwent TAVI had lower blood transfusion requirements. Two TAVI patients died: one from iliac artery injury and the other from intracardiac prosthesis migration. Patients who underwent TAVI had lower plasma levels of endotoxin and bacterial peptidoglycan, as well as lower proinflammatory cytokine levels, suggesting less gastrointestinal bacterial translocation compared with OHAVR. Compared with OHAVR, TAVI was associated with decreases in bacterial translocation and inflammation. These differences may explain the lower delirium rate and better hemodynamic stability observed, despite the greater disease severity in TAVI patients.
Nakajima, Masato; Tsuchiya, Koji; Fukuda, Shoji; Morimoto, Hironobu; Mitsumori, Yoshitaka; Kato, Kaori
2006-04-01
Aortic surgery for progressive aortic valve disease or aortic aneurysm after previous coronary artery bypass grafting (CABG) is a challenging procedure. We report the outcome of aortic reoperation after previous CABG and evaluate our management of patent grafts and our methods for obtaining myocardial protection. From February 2001 to July 2003, 6 patients with progressive aortic valve disease and aneurysm of the thoracic aorta were operated on. The group comprised 3 men and 3 women with a mean age of 67.6 years. There were 4 patients with an aneurysm of the aortic arch, 1 with chronic ascending aortic dissection, and 1 with progressive aortic valve stenosis. The interval between previous CABG and aortic surgery was 74.0 +/- 44.2 months. All reoperations were performed via median resternotomy. Myocardial protection was obtained by hypothermic perfusion of patent in-situ arterial grafts following cold-blood cardioplegia administration via the aortic root under aortic cross clamping. The operative procedure was aortic arch replacement in 4 patients, ascending aortic replacement with double CABG in 1, and aortic valve replacement in 1. All patients survived the reoperation. Postoperative maximum creatine kinase-MB was 49.2 +/- 29.8 and no new Q-waves occurred in the electrocardiogram nor were any new wall motion abnormalities recognized on echocardiography. There were no late deaths during a follow-up of 30.7 months. Reoperative aortic procedures after CABG can be performed safely with myocardial protection via hypothermic perfusion of a patent in-situ arterial graft.
CardiaMed mechanical valve: mid-term results of a multicenter clinical trial.
Nazarov, Vladimir M; Zheleznev, Sergey I; Bogachev-Prokophiev, Alexandr V; Afanasyev, Alexandr V; Nemchenko, Eugene V; Jeltovskiy, Yuri V; Lavinyukov, Sergey O
2014-01-01
Prosthesis choice is a major concern in valvular surgery. A multicenter clinical trial was performed to assess the efficacy and safety of the CardiaMed prosthetic heart valve. The study enrolled 420 patients who underwent mitral (209) or aortic (211) valve replacement from 2003 to 2004 at 7 institutions in Russia, and who were followed up from 2006 to 2011. The mean age was 52.2 ± 10.2 years (range, 12-78 years), 47.4% were female, and 99.05% completed the study. The maximum observation term was 7.5 years (2188.5 patient-years); 1081.6 patient-years for aortic and 1106.9 patient-years for mitral valve replacement. The overall 7-year survival rate was 85.1% ± 3.7%; 86.1% ± 4.8% and 84.4% ± 5.4% for aortic and mitral valve replacement, respectively. The 7-year freedom from valve-related death was 93.9% ± 3.7% and 94.5% ± 3.2% for aortic and mitral valve replacement, respectively. When early mortality (<30 days) was excluded, these rates were 94.8% ± 3.1% and 93.8% ± 3.82%, respectively. Linearized valve-dependent complication rates were determined for structural valve failure (0%/patient-year overall), thrombosis (0.63%/patient-year, all for mitral valve replacement), thromboembolic complications including transient neurologic deficits (0.13%/patient-year overall, 0.5%/patient-year for aortic valve replacement, 0.8%/patient-year for mitral valve replacement), hemorrhagic bleeding (0.64%/patient-year overall, 0.55%/patient-year for aortic valve replacement, 0.09%/patient-year for mitral valve replacement), prosthetic endocarditis (0.28%/patient-year overall, 0.28%/patient-year for aortic valve replacement, 0%/patient-year for mitral valve replacement), and hemolysis (0%/patient-year overall). The CardiaMed mechanical heart valve prostheses meets world standards of safety and efficacy.
Long-Term Outcome of the Sorin Freedom SOLO Stentless Aortic Valve.
Christ, Torsten; Claus, Benjamin; Zielinski, Christina; Falk, Volkmar; Grubitzsch, Herko
2016-11-01
The Sorin Freedom SOLO valve is a third-generation stentless aortic valve which shows beneficial hemodynamic performance compared to stented bioprostheses. Long-term results regarding hemodynamics, the durability of the valve, and patient outcome are scarce, and their acquisition was the aim of this single-center study. Between 2005 and 2006, a total of 68 consecutive patients (30 males, 38 females; mean age at surgery 76.1 ± 6.3 years) underwent aortic valve replacement with a Sorin Freedom SOLO prosthesis. Indications were aortic stenosis (n = 50), aortic regurgitation (n = 1) and mixed lesions (n = 17). Associated procedures were performed in 31 patients (45.6%), most of which were coronary artery bypass grafting (68.8 %). The follow up was performed by telephone interviews, and clinical and echocardiographic examinations. Morbidity, mortality and echocardiographic data were analyzed. The total follow up was 501.1 patient-years, with a mean follow up of 7.4 ± 3.4 years (maximum 11.2 years). The follow up was 100% complete. Hospital mortality was 4.4% (n = 3). Actuarial survival at five and 10 years was 76.5 ± 5.1% and 41.5 ± 6.5%, respectively. Reinterventions were performed in eight patients; these included three reoperations due to endocarditis, four transcatheter aortic valve implantations, and one reoperation due to structural valve deterioration (SVD). The overall freedom from valve reintervention due to SVD at five and 10 years was 97.8 ± 2.2% and 82.9 ± 7.5%, respectively. After eight years, echocardiography demonstrated peak and mean transvalvular gradients of 18 ± 11 and 10 ± 7 mmHg, respectively. The overall effective and indexed aortic valve orifice areas were 1.73 ± 0.58 cm2 and 0.92 ± 0.33 cm2/m2, respectively. At long-term follow up the Sorin Freedom SOLO bioprosthesis was associated with favourable hemodynamic results and survival. Freedom from SVD was not superior to that occurring with stented bioprostheses.
Study of phenotype evolution during childhood in Marfan syndrome to improve clinical recognition.
Stheneur, Chantal; Tubach, Florence; Jouneaux, Marlène; Roy, Carine; Benoist, Gregoire; Chevallier, Bertrand; Boileau, Catherine; Jondeau, Guillaume
2014-03-01
Because diagnosis of Marfan syndrome is difficult during infancy, we used a large cohort of children to describe the evolution of the Marfan syndrome phenotype with age. Two hundred and fifty-nine children carrying an FBN1 gene mutation and fulfilling Ghent criteria were compared with 474 non-Marfan syndrome children. Prevalence of skeletal features changed with aging: prevalence of pectus deformity increased from 43% at 0-6 years to 62% at 15-17 years, wrist signs increased from 28 to 67%, and scoliosis increased from 16 to 59%. Hypermobility decreased from 67 to 47% and pes planus decreased from 73 to 65%. Striae increased from 2 to 84%. Prevalence of ectopia lentis remained stable, varying from 66 to 72%, similar to aortic root dilatation (varying from 75 to 80%). Aortic root dilatation remained stable during follow-up in this population receiving β-blocker therapy. When comparing Marfan syndrome children with non-Marfan syndrome children, height appeared to be a simple and discriminant criterion when it was >3.3 SD above the mean. Ectopia lentis and aortic dilatation were both similarly discriminating. Ectopia lentis and aortic dilatation are the best-discriminating features, but height remains a simple discriminating variable for general practitioners when >3.3 SD above the mean. Mean aortic dilatation remains stable in infancy when children receive a β-blocker.
Byval'tsev, V A; Kalinin, A A; Stepanov, I A; Pestryakov, Yu Ya; Shepelev, V V
Cervical spondylosis and intervertebral disc (IVD) degeneration are the most common cause for compression of the spinal cord and/or its roots. Total IVD arthroplasty, as a modern alternative to surgical treatment of IVD degeneration, is gaining popularity in many neurosurgical clinics around the world. Aim - the study aim was to conduct a multicenter analysis of cervical spine arthroplasty with an IVD prosthesis M6-C ('Spinal Kinetics', USA). The study included 112 patients (77 males and 35 females). All patients underwent single-level discectomy with implantation of the artificial IVD prosthesis M6-C. The follow-up period was up to 36 months. Dynamic assessment of the prosthesis was based on clinical parameters (pain intensity in the cervical spine and upper extremities (visual analog scale - VAS); quality of life (Neck Disability Index - NDI)); and subjective satisfaction with the results of surgical treatment (Macnab scale) and instrumental data (range of motion in the operated spinal motion segment, degree of heterotopic ossification (McAfee-Suchomel classification), and time course of degenerative changes in the adjacent segments).
Peng, Liqing; Yu, Jianqun; Li, Zhenlin; Li, Wanjiang; Cheng, Wei
2016-10-01
The purpose of this study was to explore the feasibility of dual-source computed tomography(DSCT)highpitch scan mode in the preoperative evaluation of severe aortic stenosis(AS)referred to transcatheter aortic valve implantation(TAVI).Thirty patients with severe AS referred for TAVI underwent cervico-femoral artery joint DSCT angiography.Measurement and calculation of contrast,contrast noise ratio(CNR)and noise of aorta and access vessels were performed.The intra-and inter-observer reproducibilities for assessing aortic root and access vessels were evaluated.Evaluation of shape and plagues of aorta and access vessels was performed.The contrast,CNR and noise of aorta and access vessels were 348.2~457.9HU,12.2~30.3HU and 19.1~48.1 HU,respectively.There were good intra-and inter-observer reproducibilities in assessing aortic root and access vessels by DSCT(mean difference:-0.73~0.79 mm,r=0.90~0.98,P<0.001;mean difference:-0.70~0.73 mm,r=0.90~0.96,P<0.001).In the 30 patients,the diameters of external iliac artery,femeral artery or subclavian artery were less than 7mm in 5cases(16.7%),marked calcification in bilateral common iliac arteries in 1case(3.3%)and marked soft plaque in left common iliac artery in 1case(3.3%).DSCT high-pitch scan mode was feasible in the preoperative evaluation of aorta and access vessels in patients with AS referred for TAVI.
Rodríguez-Palomares, José Fernando; Dux-Santoy, Lydia; Guala, Andrea; Kale, Raquel; Maldonado, Giuliana; Teixidó-Turà, Gisela; Galian, Laura; Huguet, Marina; Valente, Filipa; Gutiérrez, Laura; González-Alujas, Teresa; Johnson, Kevin M; Wieben, Oliver; García-Dorado, David; Evangelista, Arturo
2018-04-26
In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype. One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models. The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype. Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population.
Litzler, Pierre-Yves; Borz, Bogdan; Smail, Hassiba; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Tron, Christophe; Godin, Matthieu; Caudron, Jerome; Hauville, Camille; Dacher, Jean-Nicolas; Cribier, Alain; Eltchaninoff, Hélène; Bessou, Jean-Paul
2012-03-01
The first French transapical transcatheter aortic valve implantation (TAVI) was performed in July 2007 in our department. To report 4-year outcomes of transapical implantation with the Edwards transcatheter bioprosthesis. We prospectively evaluated consecutive patients who underwent transapical implantation with an Edwards transcatheter bioprosthesis between July 2007 and October 2011. Patients were not suitable for conventional surgery (due to severe comorbidities) or transfemoral implantation (due to poor femoral access). Among 61 patients (59.0% men), mean logistic EuroSCORE was 27.5 ± 14.9% and mean age was 81.0 ± 6.8 years. Successful valve implantation was achieved in 59/61 patients (96.7%) of patients. The other two patients required conversion to conventional surgery due to prosthesis embolization and died. Six additional patients died in the postoperative period. Causes of perioperative death were two septic shocks (one of peritonitis), two multi-organ failure, one ventricular fibrillation and one respiratory insufficiency. Intraprocedural stroke was not observed in any patient. The actuarial survival rates at 1, 2 and 4 years were 73.8%, 67.2% and 41.0%. During this 4-year period, four patients died of cardiovascular events, but no impairment of transprosthesis gradient was observed. Our series of 61 patients who underwent transapical implantation of the Edwards transcatheter bioprosthesis shows satisfactory results, similar to other reports, considering the high level of severity of patients referred for this method. Transapical access is a reliable alternative method for patients that cannot benefit from a transfemoral approach. Copyright © 2012. Published by Elsevier Masson SAS.
Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V
2011-04-01
Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Olivieri, Laura J.; Baba, Ridhwan Y.; Arai, Andrew E.; Bandettini, W. Patricia; Rosing, Douglas R.; Bakalov, Vladimir; Sachdev, Vandana; Bondy, Carolyn A.
2014-01-01
Background Congenital aortic valve fusion is associated with aortic dilation, aneurysm and rupture in girls and women with Turner syndrome (TS). Our objective was to characterize aortic valve structure in subjects with TS, and determine the prevalence of aortic dilation and valve dysfunction associated with different types of aortic valves. Methods and Results The aortic valve and thoracic aorta were characterized by cardiovascular magnetic resonance imaging in 208 subjects with TS in an IRB-approved natural history study. Echocardiography was used to measure peak velocities across the aortic valve, and the degree of aortic regurgitation. Four distinct valve morphologies were identified: tricuspid aortic valve (TAV) 64%(n=133), partially fused aortic valve (PF) 12%(n=25), bicuspid aortic valve (BAV) 23%(n=47), and unicuspid aortic valve (UAV) 1%(n=3). Age and body surface area (BSA) were similar in the 4 valve morphology groups. There was a significant trend, independent of age, towards larger BSA-indexed ascending aortic diameters (AADi) with increasing valve fusion. AADi were (mean +/− SD) 16.9 +/− 3.3 mm/m2, 18.3 +/− 3.3 mm/m2, and 19.8 +/− 3.9 mm/m2 (p<0.0001) for TAV, PF and BAV+UAV respectively. PF, BAV, and UAV were significantly associated with mild aortic regurgitation and elevated peak velocities across the aortic valve. Conclusions Aortic valve abnormalities in TS occur with a spectrum of severity, and are associated with aortic root dilation across age groups. Partial fusion of the aortic valve, traditionally regarded as an acquired valve problem, had an equal age distribution and was associated with an increased AADi. PMID:24084490
Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian
2017-06-01
Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.
Ascending aorta dilatation in patients with bicuspid aortic valve stenosis: a prospective CMR study.
Rossi, Alexia; van der Linde, Denise; Yap, Sing Chien; Lapinskas, Thomas; Kirschbaum, Sharon; Springeling, Tirza; Witsenburg, Maarten; Cuypers, Judith; Moelker, Adriaan; Krestin, Gabriel P; van Dijk, Arie; Johnson, Mark; van Geuns, Robert-Jan; Roos-Hesselink, Jolien W
2013-03-01
The aim of this study was to evaluate the natural progression of aortic dilatation and its association with aortic valve stenosis (AoS) in patients with bicuspid aortic valve (BAV). Prospective study of aorta dilatation in patients with BAV and AoS using cardiac magnetic resonance (CMR). Aortic root, ascending aorta, aortic peak velocity, left ventricular systolic and diastolic function and mass were assessed at baseline and at 3-year follow-up. Of the 33 enrolled patients, 5 needed surgery, while 28 patients (17 male; mean age: 31 ± 8 years) completed the study. Aortic diameters significantly increased at the aortic annulus, sinus of Valsalva and tubular ascending aorta levels (P < 0.050). The number of patients with dilated tubular ascending aortas increased from 32 % to 43 %. No significant increase in sino-tubular junction diameter was observed. Aortic peak velocity, ejection fraction and myocardial mass significantly increased while the early/late filling ratio significantly decreased at follow-up (P < 0.050). The progression rate of the ascending aorta diameter correlated weakly with the aortic peak velocity at baseline (R (2) = 0.16, P = 0.040). BAV patients with AoS showed a progressive increase of aortic diameters with maximal expression at the level of the tubular ascending aorta. The progression of aortic dilatation correlated weakly with the severity of AoS.
Transarterial pacemaker lead implantation results in acute myocardial infarction.
Issa, Ziad F; Gill, John B
2010-11-01
We report a case of inadvertent transarterial implantation of dual-chamber pacemaker leads; the ventricular lead positioned across the aortic valve into the left ventricle and the atrial lead curving in the aortic root with the tip positioned into the left circumflex artery, resulting in acute myocardial infarction. The diagnosis was made based on the finding on the chest X-ray, surface ECG, and coronary angiography.
Doppler-guided retrograde catheterization system
NASA Astrophysics Data System (ADS)
Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.
1991-05-01
The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the catheter tip is placed in the aortic root. Such technology may conceivably assist in allowing selective coronary catheterization. These studies have demonstrated that Doppler guided retrograde catheterization provides an accurate method to catheterization the aortic root and left ventricular chamber without x-ray. In humans, it may prove useful in a variety of settings including the development of invasive ultrasonic diagnostic and therapeutic technology.
Pulerwitz, Todd C; Khalique, Omar K; Nazif, Tamim N; Rozenshtein, Anna; Pearson, Gregory D N; Hahn, Rebecca T; Vahl, Torsten P; Kodali, Susheel K; George, Isaac; Leon, Martin B; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J
2016-01-01
Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30 mL/min) who underwent a novel VLCV protocol (20 mL of iohexol at 2.5 mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. VLCV patients had mean (±SD) age 86 ± 6.5, BMI 23.9 ± 3.4 kg/m(2) with 54% men; SCV patients age 83 ± 8.8, BMI 28.7 ± 5.3 kg/m(2), 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Choudhary, Shiv Kumar; Abraham, Atul; Bhoje, Amol; Gharde, Parag; Sahu, Manoj; Talwar, Sachin; Airan, Balram
2017-11-01
The present study evaluates the feasibility, safety, and efficacy of edge-to-edge repair for moderate secondary/functional mitral regurgitation in patients undergoing aortic valve/root interventions. Sixteen patients underwent transaortic edge-to-edge mitral valve repair. Mitral regurgitation was 2+ in 8 patients and 3+ in 6 patients. Two patients in whom cardiac arrest developed preoperatively had severe (4+) mitral regurgitation. Patients underwent operation for severe aortic regurgitation ± aortic root lesions. The mean left ventricular systolic and diastolic diameters were 51.5 ± 12.8 mm and 70.7 ± 10.7 mm, respectively. Left ventricular ejection fraction ranged from 20% to 60%. Primary surgical procedure included Bentall's ± hemiarch replacement in 10 patients, aortic valve replacement in 5 patients, and noncoronary sinus replacement with aortic valve repair in 1 patient. Severity of mitral regurgitation decreased to trivial or zero in 13 patients, 1+ in 2 patients, and 2+ in 1 patient. There were no gradients across the mitral valve in 9 patients, less than 5 mm Hg in 6 patients, and 9 mm Hg in 1 patient. There was no operative mortality. Follow-up ranged from 2 weeks to 54 months. Echocardiography showed trivial or no mitral regurgitation in 12 patients, 1+ in 2 patients, and 2+ in 2 patients. None of the patients had significant mitral stenosis. The mean left ventricular systolic and diastolic diameters decreased to 40.5 ± 10.3 mm and 58.7 ± 11.6 mm, respectively. Ejection fraction also improved slightly (22%-65%). Transaortic edge-to-edge mitral valve repair is a safe and effective technique to abolish secondary/functional mitral regurgitation. However, its impact on overall survival needs to be studied. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Vasan, Ramachandran S; Glazer, Nicole L; Felix, Janine F; Lieb, Wolfgang; Wild, Philipp S; Felix, Stephan B; Watzinger, Norbert; Larson, Martin G; Smith, Nicholas L; Dehghan, Abbas; Grosshennig, Anika; Schillert, Arne; Teumer, Alexander; Schmidt, Reinhold; Kathiresan, Sekar; Lumley, Thomas; Aulchenko, Yurii S; König, Inke R; Zeller, Tanja; Homuth, Georg; Struchalin, Maksim; Aragam, Jayashri; Bis, Joshua C; Rivadeneira, Fernando; Erdmann, Jeanette; Schnabel, Renate B; Dörr, Marcus; Zweiker, Robert; Lind, Lars; Rodeheffer, Richard J; Greiser, Karin Halina; Levy, Daniel; Haritunians, Talin; Deckers, Jaap W; Stritzke, Jan; Lackner, Karl J; Völker, Uwe; Ingelsson, Erik; Kullo, Iftikhar; Haerting, Johannes; O'Donnell, Christopher J; Heckbert, Susan R; Stricker, Bruno H; Ziegler, Andreas; Reffelmann, Thorsten; Redfield, Margaret M; Werdan, Karl; Mitchell, Gary F; Rice, Kenneth; Arnett, Donna K; Hofman, Albert; Gottdiener, John S; Uitterlinden, Andre G; Meitinger, Thomas; Blettner, Maria; Friedrich, Nele; Wang, Thomas J; Psaty, Bruce M; van Duijn, Cornelia M; Wichmann, H-Erich; Munzel, Thomas F; Kroemer, Heyo K; Benjamin, Emelia J; Rotter, Jerome I; Witteman, Jacqueline C; Schunkert, Heribert; Schmidt, Helena; Völzke, Henry; Blankenberg, Stefan
2009-07-08
Echocardiographic measures of left ventricular (LV) structure and function are heritable phenotypes of cardiovascular disease. To identify common genetic variants associated with cardiac structure and function by conducting a meta-analysis of genome-wide association data in 5 population-based cohort studies (stage 1) with replication (stage 2) in 2 other community-based samples. Within each of 5 community-based cohorts comprising the EchoGen consortium (stage 1; n = 12 612 individuals of European ancestry; 55% women, aged 26-95 years; examinations between 1978-2008), we estimated the association between approximately 2.5 million single-nucleotide polymorphisms (SNPs; imputed to the HapMap CEU panel) and echocardiographic traits. In stage 2, SNPs significantly associated with traits in stage 1 were tested for association in 2 other cohorts (n = 4094 people of European ancestry). Using a prespecified P value threshold of 5 x 10(-7) to indicate genome-wide significance, we performed an inverse variance-weighted fixed-effects meta-analysis of genome-wide association data from each cohort. Echocardiographic traits: LV mass, internal dimensions, wall thickness, systolic dysfunction, aortic root, and left atrial size. In stage 1, 16 genetic loci were associated with 5 echocardiographic traits: 1 each with LV internal dimensions and systolic dysfunction, 3 each with LV mass and wall thickness, and 8 with aortic root size. In stage 2, 5 loci replicated (6q22 locus associated with LV diastolic dimensions, explaining <1% of trait variance; 5q23, 12p12, 12q14, and 17p13 associated with aortic root size, explaining 1%-3% of trait variance). We identified 5 genetic loci harboring common variants that were associated with variation in LV diastolic dimensions and aortic root size, but such findings explained a very small proportion of variance. Further studies are required to replicate these findings, identify the causal variants at or near these loci, characterize their functional significance, and determine whether they are related to overt cardiovascular disease.
Jamieson, W R Eric
2006-01-01
Since the 2002 Surgical Technology International monograph on valvular prostheses, there have been significant developmental and investigative advances. Aortic bioprostheses and mechanical prostheses have undergone design changes to optimize hemodynamics and prevent patient-prosthesis mismatch to have a potential satisfactory influence on survival. There has been continual technological improvements striving to bring forward advances that improve the durability of bioprostheses and reduce the thrombogenicity of mechanical prostheses. There also has been a continuance to preserve biological tissue with glutaraldehyde, rather than clinically evaluate other cross-linking technologies, by controlling or retarding calcification with therapies to control phospholipids and residual aldehydes. The techniques of mitral valve reconstruction have now been well established and new annuloplasty rings have been designed for the potential of maintaining the anatomical and physiological characteristics of the mitral annulus. Several objectives exist for annuloplasty, namely remodeling of the length and shape of the dilated annulus, prevention of dilatation of the annulus, and support for the potentially fragile area after partial-leaflet resection. Currently, there exists an emergence of catheter-based therapies for management of aortic stenosis and mitral regurgitation. For management of selected populations with critical aortic stenosis, techniques for aortic valve substitution have been developed for both antegrade and retrograde catheter techniques, as well as apical transventricular implantation. Mitral regurgitation has been addressed by experimental transcoronary sinus, stent-like devices and transventricular, edge-to-edge leaflet devices. The devices, descriptions and pictorial images comprise this monograph.
Latib, Azeem; Pedersen, Wesley; Maisano, Francesco; Lesser, John; Ruparelia, Neil; Figini, Filippo; Colombo, Antonio; Poulose, Anil; Kolbeck, James; Mooney, Michael; Schwartz, Robert; Youssef, Alicia; Ungs, David; Goldenberg, Irv; Sorajja, Paul
2016-06-01
The aim of this study was to assess the effect of a novel hourglass-shaped balloon on reduction of paravalvular leak (PVL) in patients undergoing transcatheter aortic valve replacement (TAVR) with self-expanding prostheses. An important limitation of TAVR compared with surgical aortic valve replacement remains the higher incidence of PVL. A commonly used strategy to treat PVL is balloon postdilatation (BPD); however, the optimal technique for treating PVL after TAVR is unknown. We examined consecutive patients with severe, symptomatic aortic stenosis who underwent TAVR with the Medtronic CoreValve followed by BPD with an InterValve V8 balloon for PVL grade ≥2+. Data from echocardiographic, multidetector computed tomographic, and angiographic images were reviewed. The primary endpoint was successful reduction in PVL to grade 1+ or less as assessed by intraprocedural echocardiography. Eleven patients were studied (median age, 82 years; 64% female). Ten patients (91%) demonstrated successful reduction in PVL after V8 BPD. In three patients, PVL was reduced to zero or trace. PVL remained unchanged in one patient (2+). Two patients had complete heart block associated with valve deployment and received permanent pacemakers. There were no occurrences of annular injury or major adverse clinical events. BPD with the V8 hourglass-shaped balloon was feasible in reducing PVL from self-expanding TAVR prostheses. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi
2006-01-01
Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.
Outcomes After Operations for Unicuspid Aortic Valve With or Without Ascending Repair in Adults
Zhu, Yuanjia; Roselli, Eric E.; Idrees, Jay J.; Wojnarski, Charles M.; Griffin, Brian; Kalahasti, Vidyasagar; Pettersson, Gosta; Svensson, Lars G.
2016-01-01
Background Unicuspid aortic valve is an important subset of bicuspid aortic valve, and knowledge regarding its aortopathy pattern and surgical outcomes is limited. Our objectives were to characterize unicuspid aortic valve patients, associated aortopathy, and surgical outcomes. Methods From January 1990 to May 2013, 149 adult unicuspid aortic valve patients underwent aortic valve replacement or repair for aortic stenosis (n = 13), regurgitation (n = 13), or both (n = 123), and in 91 (61%) the aortic valve operation was combined with aortic repair. Data were obtained from the Cardiovascular Information Registry and medical record review. Three-dimensional imaging analysis was performed from preoperative computed tomography and magnetic resonance imaging scans. The Kaplan-Meier method was used for survival analysis. Results Patients had a mean maximum aortic diameter of 44 ± 8 mm and variably involved the aortic root, ascending, or arch, or both. Patients with valve operations alone were more likely to be hypertensive (p = 0.01) and to have severe aortic stenosis (p = 0.07) than those who underwent concurrent aortic operations. There were no operative deaths, strokes, or myocardial infarctions. Patients undergoing aortic repair had better long-term survival. Estimated survival at 1, 5, and 10 years was 100%, 100%, and 100% after combined operations and was 100%, 88%, and 88% after valve operations alone (p = 0.01). Conclusions Patients with a dysfunctional unicuspid aortic valve frequently present with an ascending aneurysm that requires repair. Combined aortic valve operations and aortic repair was associated with significantly better long-term survival than a valve operation alone. Further study of this association may direct decisions about timing of surgical intervention. PMID:26453423
Yokoyama, Shinya; Nagato, Hisao; Yoshida, Yuichi; Nagasaka, Shigeo; Kaneda, Kozo; Nishiwaki, Noboru
2016-01-16
Although repair of a supravalvular aortic stenosis (SVAS) can be performed with low mortality rates, surgery for the complex form of SVAS continues to be associated with a high incidence of residual stenosis. The patient was referred to our hospital at 1 month of age and was diagnosed with aortic valve stenosis (AS) by using echocardiography. Cardiac catheterization revealed moderate AS, and subsequent left ventriculography revealed discrete stenosis of the sino-tubular junction and a narrowed proximal ascending aorta. We performed a reconstructive operation for such heart defects involving novel three-sinus and ascending aorta enlargement without aortic root transection in a 6-month-old boy. Our novel three-sinus enlargement technique is suitable for treating each type of SVAS and is a useful method for a baby particularly less than 10 kg without disturbing the growth of the ascending aorta.
Acute Aortic Dissection in Pregnancy in a Woman with Undiagnosed Marfan Syndrome
Master, Mandana; Day, Gavin
2012-01-01
We report a case of acute aortic dissection in a lady of 28 weeks of gestation with undiagnosed Marfan syndrome. The patient had been seen in our antenatal clinics. Her history documented in her pregnancy record was negative for genetic/congenital abnormalities. There was no family history documented. Subsequently, at 28 weeks of gestation, the patient presented with sudden onset chest, jaw, and back pain. Further history revealed that her father had died at the age of 27 of an aortic dissection. Echocardiography showed aortic root dissection with occlusion of aortic branches. She subsequently underwent an emergency lower segment caesarean section followed by surgical repair of type A dissection. A simultaneous type B dissection was managed conservatively. On later examination, our patient fulfilled the diagnostic criteria for phenotypic expression of Marfan syndrome. Genetic testing also confirmed that she has a mutation of the fibrillin (FBN 1) gene associated with the disease. PMID:23304584
[Late outlet strut fracture of an aortic Björk-Shiley and embolization of the prosthetic disc].
Brochet, E; Bougis de Brux, M A; Assayag, P; Benacin, Y; Gamerman, G; Guerot, C; Valère, P E
1988-09-01
A new case of late fracture of an outlet strut in a convexo-concave Björk-Shiley valve is reported. The fracture occurred 6 years after aortic implantation of the valve and was responsible for aorto-iliac embolization by the prosthetic disc and death of the patient from cardiogenic shock. This not uncommon complication of the Björk-Shiley valve prosthesis is usually ascribed to the relative fragility of its outlet strut welded to the metallic ring and subjected to strong pressures. Although most cases were observed within the first two years of prosthetic valve insertion, and mainly with valves manufactured in 1981 and 1982, our case and a few others demonstrate the possibility of late rupture. Cardiologists must be aware of this possible complication, since in some favourable cases it can be diagnosed at an early stage and the patient's life can be saved by an emergency operation.
An overview of removable partial overdentures.
McDermott, I G; Samant, A
1990-02-01
As an alternative to complete dentures, overdentures are well established as a sound therapeutic modality for patients with terminal dentition. By utilizing natural tooth roots and their periodontal structures to aid in support, overdentures maintain proprioceptive mediation and a mechanism for masticatory force vectors that favor bone retention over bond resorption. The degree of stability enhancement and denture retention from retained roots varies with the design and environment of the prosthesis. This article reviews various aspects of removable partial over-denture use.
Ferumoxytol MRA for transcatheter aortic valve replacement planning with renal insufficiency.
Kallianos, Kimberly; Henry, Travis S; Yeghiazarians, Yerem; Zimmet, Jeffrey; Shunk, Kendrick A; Tseng, Elaine E; Mahadevan, Vaikom; Hope, Michael D
2017-03-15
Computed tomography angiography (CTA) is the test of choice for pre-procedure imaging of transcatheter aortic valve replacement (TAVR) candidates. The iodinated contrast required, however, increases the risk of renal dysfunction in patients with pre-existing renal failure. Ferumoxytol is a magnetic resonance imaging (MRI) contrast agent that can be used with renal failure. Its long vascular resonance time allows gated MRA sequences that approach CTA in image quality. We present respiratory and cardiac gated MRA enabled by ferumoxytol that can be post-processed in an analogous fashion to CTA. Seven patients with renal failure presenting for TAVR were imaged with respiratory and cardiac gated MRA at 3T using ferumoxtyol for contrast. Aortic annulus, root and peripheral access dimensions were calculated in a fashion identical to that used for CTA. Of these, 6 patients underwent a TAVR procedure and 5 had intraoperative valve assessment with transesophageal echocardiograph (TEE) using standard clinical protocols that employed both two- and three-dimensional techniques. Good correlation between MRA aortic annulus measurements and those from TEE were shown in 5 patients with mean annulus area of 392.4mm 2 (290-470 range) versus 374.1mm 2 (285-440 range), with a pairwise correlation coefficient of 0.92, p=0.029. All patients received Sapien valve implants (one 20mm, three 23mm, and two 26mm valves). Access decisions were guided by MRA with no complications. Annulus sizing resulted in no greater than trace/mild aortic regurgitation in all patients. Ferumoxytol MRA is a safe alternative to CTA in patients with renal failure for pre-TAVR analysis of the aortic root and peripheral access. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Aortic events in a nationwide Marfan syndrome cohort.
Groth, Kristian A; Stochholm, Kirstine; Hove, Hanne; Kyhl, Kasper; Gregersen, Pernille A; Vejlstrup, Niels; Østergaard, John R; Gravholt, Claus H; Andersen, Niels H
2017-02-01
Marfan syndrome is associated with morbidity and mortality due to aortic dilatation and dissection. Preventive aortic root replacement has been the standard treatment in Marfan syndrome patients with aortic dilatation. In this study, we present aortic event data from a nationwide Marfan syndrome cohort. The nationwide cohort of Danish Marfan syndrome patients was established from the Danish National Patient Registry and the Cause of Death Register, where we retrieved information about aortic surgery and dissections. We associated aortic events with age, sex, and Marfan syndrome diagnosis prior or after the first aortic event. From the total cohort of 412 patients, 150 (36.4 %) had an aortic event. Fifty percent were event free at age 49.6. Eighty patients (53.3 %) had prophylactic surgery and seventy patients (46.7 %) a dissection. The yearly event rate was 0.02 events/year/patient in the period 1994-2014. Male patients had a significant higher risk of an aortic event at a younger age with a hazard ratio of 1.75 (CI 1.26-2.42, p = 0.001) compared with women. Fifty-three patients (12.9 %) were diagnosed with MFS after their first aortic event which primarily was aortic dissection [n = 44 (83.0 %)]. More than a third of MFS patients experienced an aortic event and male patients had significantly more aortic events than females. More than half of the total number of dissections was in patients undiagnosed with MFS at the time of their event. This emphasizes that diagnosing MFS is lifesaving and improves mortality risk by reducing the risk of aorta dissection.
Masri, Ahmad; Kalahasti, Vidyasagar; Svensson, Lars G; Alashi, Alaa; Schoenhagen, Paul; Roselli, Eric E; Johnston, Douglas R; Rodriguez, L Leonardo; Griffin, Brian P; Desai, Milind Y
2017-06-01
In patients with bicuspid aortic valve and dilated proximal ascending aorta, we sought to assess (1) factors associated with increased longer-term cardiovascular mortality and (2) incremental prognostic use of indexing aortic root to patient height. We studied 969 consecutive bicuspid aortic valve patients (50±13 years; 87% men) with proximal aorta ≥4 cm, who also had a gated contrast-enhanced thoracic computed tomography or magnetic resonance angiography. A ratio of ascending aortic area/height was calculated on tomography, and ≥10 cm 2 /m was considered abnormal, as previously reported. Society of Thoracic Surgeons score and cardiovascular death were recorded. Greater than or equal to III+ aortic regurgitation and severe aortic stenosis were seen in 37% and 10%, respectively. Society of Thoracic Surgeons score and right ventricular systolic pressure were 2±3 and 15±16 mm Hg, respectively. Abnormal ascending aortic area/height ratio was noted in 33%; 44% underwent ascending aortic surgery at 34 days. At 10.8 years (interquartile range, 9.6-12.3), 82 (9%) died (0.4% in-hospital postoperative mortality). On multivariable Cox survival analysis, ascending aortic area/height ratio (hazard ratio, 2; 95% confidence interval, 1.20-3.35) was associated with cardiovascular death, whereas aortic surgery (hazard ratio, 0.46; confidence interval, 0.26-0.80) was associated with improved survival (both P <0.01). Of the 405 patients with ascending aortic diameter of 4.5 to 5.5 cm, 64% had an abnormal ascending aortic area/height ratio, and 70% deaths occurred in patients with an abnormal ratio. In bicuspid aortic valve patients with dilated proximal ascending aorta, ascending aortic area/height ratio was independently associated with cardiovascular death. © 2017 American Heart Association, Inc.
El-Gamel, Adam
2013-01-01
Transcatheter aortic valve replacement (TAVR) has, without a doubt, brought an unprecedented excitement to the field of interventional cardiology. The avoidance of a sternotomy by transfemoral or transapical aortic-valve implantation appears to come at the price of some serious complications, including an increased risk of embolic stroke and paravalvular leakage. The technical challenges of the procedure and the complex nature of the high-risk patient cohort make the learning curve for this procedure a steep one, with the potential for unexpected complications always looming. Although most commonly relating to vascular access, these complications can also result from prosthesis-related trauma or malposition, or from unanticipated trauma from the pacing wire or the super stiff wire. Sudden and unexplained hypotension is often the earliest indicator of major complication and must prompt an immediate and detailed exclusion of five major pathologies: retroperitoneal bleeding from access site rupture, aortic dissection or rupture, pericardial tamponade, coronary ostial obstruction, or acute severe aortic regurgitation. In most cases, these can be dealt with quickly, and by percutaneous means, although open surgery may occasionally be necessary. Increased operator and team experience should make prevention and recognition of these catastrophic complications more complete. For this reason, the importance of specific training, such as that provided by the valve manufacturers through workshops and proctorship, cannot be overemphasized. It is essential that all operators, and indeed all members of the implant team, exert extreme vigilance to the development of intraprocedural complications, which could have rapid and potentially lethal consequences. Greater experience with an improved understanding of these risks, along with the development of better devices, deliverable through smaller and less traumatic sheath technology, will undoubtedly improve the safety and, potentially, widen the applicability of TAVR in the future. Forthcoming innovations include a newer generation of the valves with operator-controlled steerability to facilitate negotiation of tortuous aortic anatomy, as well as fully retrievable and resheathable devices to accommodate the events of dislocation or embolization. The fact that Transcatheter aortic valve implantation (TAVI) is new implies learning from experience but also from mistakes. The TAVI team must be vigilant to recognize and diagnose intraprocedure severe hypotension. The “perilous pentad” of catastrophic causes must be constantly borne in mind: retroperitoneal bleeding from access site rupture, aortic dissection or rupture, pericardial tamponade, coronary ostial obstruction, and acute severe aortic insufficiency. PMID:26798706
An unusual cause of hemolysis in a patient with an aortic valved conduit replacement.
Allman, Christine; Rajaratnam, Rohan; Kachwalla, Hashim; Hughes, Clifford F; Bannon, Paul; Leung, Dominic Y
2003-02-01
Hemolytic anemia is a well-known but uncommon complication in patients with prosthetic heart valves. It is most commonly a result of prosthetic valve dysfunction, periprosthetic valvular regurgitation, or both. We report a case of a 41-year-old man who had a previous aortic valve and root replacement for acute proximal aortic dissection, now presenting with hemolytic anemia. This was a result of flow obstruction at the distal anastomosis of the aortic conduit by the presence of multiple dissection flaps resulting in severe flow turbulence. Although the pathology was at the blind spot for transesophageal echocardiography, the dissection flaps, the flow turbulence, and the degree of obstruction were well-demonstrated by this technique after careful manipulation of the probe and a high index of suspicion.
Bettinger, Nicolas; Khalique, Omar K; Krepp, Joseph M; Hamid, Nadira B; Bae, David J; Pulerwitz, Todd C; Liao, Ming; Hahn, Rebecca T; Vahl, Torsten P; Nazif, Tamim M; George, Isaac; Leon, Martin B; Einstein, Andrew J; Kodali, Susheel K
The threshold for the optimal computed tomography (CT) number in Hounsfield Units (HU) to quantify aortic valvular calcium on contrast-enhanced scans has not been standardized. Our aim was to find the most accurate threshold to predict paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). 104 patients who underwent TAVR with the CoreValve prosthesis were studied retrospectively. Luminal attenuation (LA) in HU was measured at the level of the aortic annulus. Calcium volume score for the aortic valvular complex was measured using 6 threshold cutoffs (650 HU, 850 HU, LA × 1.25, LA × 1.5, LA+50, LA+100). Receiver-operating characteristic (ROC) analysis was performed to assess the predictive value for > mild PVR (n = 16). Multivariable analysis was performed to determine the accuracy to predict > mild PVR after adjustment for depth and perimeter oversizing. ROC analysis showed lower area under the curve (AUC) values for fixed threshold cutoffs (650 or 850 HU) compared to thresholds relative to LA. The LA+100 threshold had the highest AUC (0.81), and AUC was higher than all studied protocols, other than the LA x 1.25 and LA + 50 protocols, where the difference approached statistical significance (p = 0.05, and 0.068, respectively). Multivariable analysis showed calcium volume determined by the LAx1.25, LAx1.5, LA+50, and LA+ 100 HU protocols to independently predict PVR. Calcium volume scoring thresholds which are relative to LA are more predictive of PVR post-TAVR than those which use fixed cutoffs. A threshold of LA+100 HU had the highest predictive value. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Ugur, Murat; Byrne, John G; Bavaria, Joseph E; Cheung, Anson; Petracek, Michael; Groh, Mark A; Suri, Rakesh M; Borger, Michael A; Schaff, Hartzell V
2014-10-01
The study objective was to evaluate whether aortic valve replacement with the Trifecta valve (St Jude Medical Inc, St Paul, Minn) using simple sutures produces better hemodynamic performance than valve replacement with noneverting pledget-reinforced sutures. We analyzed prospectively acquired 1-year hemodynamic data of patients with small aortic annulus sizes who were enrolled in a multicenter trial of the Trifecta aortic valve bioprosthesis and underwent aortic valve replacement with a 19-mm or 21-mm bioprosthesis between August 2007 and November 2009. We compared preoperative clinical information and 1-year postoperative hemodynamic data for noneverting pledget-reinforced sutures (group 1) versus everting mattress sutures or simple sutures (group 2). A total of 346 patients underwent aortic valve replacement: 269 in group 1 and 77 in group 2. Preoperative demographic characteristics for the 2 groups were similar. For groups 1 and 2, the mean gradient was 10.4±4.7 mm Hg and 11.1±4.4 mm Hg for 19-mm valves, respectively, and 8.4±3.5 mm Hg and 8.8±3.6 mm Hg for 21-mm valves, respectively; the effective orifice area was 1.40 cm2 and 1.25 cm2 for 19-mm valves, respectively, and 1.57 cm2 and 1.50 cm2 for 21-mm valves, respectively. The rate of severe prosthesis-patient mismatch (indexed effective orifice area≤0.65 cm2/m2) was 18.6% (n=11) and 25% (n=6) for 19-mm valves, respectively, and 10.9% (n=20) and 16.3% (n=8) for 21-mm valves, respectively. The suture method did not affect hemodynamic performance of supra-annular bioprostheses in patients with small aortic annulus sizes. Choice of suture technique should be determined by surgeon experience and local anatomic features. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
[Arterial involvements in hereditary dysplasia of the connective tissue].
Beylot, C; Doutre, M S; Beylot-Barry, M; Busquet, M
1994-03-01
Arterial involvement is an important feature of the diagnosis and, above all, prognosis of heritable disorders of connective tissue. In pseudoxanthoma elasticum, a progressive occlusive syndrome is associated with hemorrhage and especially with gastrointestinal bleeding. Aneurysms are uncommon. Hypertension occurs frequently. Cutaneous signs (yellowish pseudo xanthomatous papules of the large folds) the ocular changes (angioid streaks) and pathology showing numerous, thickened, fragmented, disorganized, calcified elastic fibers in the deep dermis and arterial walls, allow the diagnosis to be made. In the heterogeneous group of Ehlers-Danlos syndromes, type IV is characterized by sudden spontaneous rupture of the large arteries. Aneurysms and carotido-cavernous fistulae are rather frequent. Owing to friability of the arterial walls, arteriograms and other procedure requiring arterial puncture may prove hazardous and surgery difficult. Such patients have an acrogeric morphotype, and thin, fragile skin, but cutaneous hyperelasticity and joint hyperlaxity are usually minimal. Pathology evidences collagen hypoplasia in the skin and arterial walls. The severity of Marfan syndrome is due to aortic involvement. A fusiform aneurysm of the ascending aorta represents a vital risk of rupture. Aortic root dilatation is associated and responsible of severe aortic regurgitation. Aortic dissection is also a serious threat. Improved surgical techniques for repairing a dilated or dissected aortic root with simultaneous replacement of the aortic valve increases the life expectancy of such patients. Dolichomorphism is the characteristic skeletal abnormality, particularly with arachnodactyly and upward ectopia lentis, which is almost bilateral, is a very frequent feature of Marfan syndrome. The most typical histological finding is aortic cystic median necrosis. The basic defect in Marfan syndrome concerns the fibrillin, whose gene is located on chromosome 15. The three diseases detailed in this paper constitute the main areas of this subject, but arterial involvement may occur in other inheritable disorders of connective tissue (osteogenesis imperfecta, cutis laxa, Werner syndrome, Menkes syndrome, etc).
Evaluation of simulation training in cardiothoracic surgery: the Senior Tour perspective.
Fann, James I; Feins, Richard H; Hicks, George L; Nesbitt, Jonathan C; Hammon, John W; Crawford, Fred A
2012-02-01
The study objective was to introduce senior surgeons, referred to as members of the "Senior Tour," to simulation-based learning and evaluate ongoing simulation efforts in cardiothoracic surgery. Thirteen senior cardiothoracic surgeons participated in a 2½-day Senior Tour Meeting. Of 12 simulators, each participant focused on 6 cardiac (small vessel anastomosis, aortic cannulation, cardiopulmonary bypass, aortic valve replacement, mitral valve repair, and aortic root replacement) or 6 thoracic surgical simulators (hilar dissection, esophageal anastomosis, rigid bronchoscopy, video-assisted thoracoscopic surgery lobectomy, tracheal resection, and sleeve resection). The participants provided critical feedback regarding the realism and utility of the simulators, which served as the basis for a composite assessment of the simulators. All participants acknowledged that simulation may not provide a wholly immersive experience. For small vessel anastomosis, the portable chest model is less realistic compared with the porcine model, but is valuable in teaching anastomosis mechanics. The aortic cannulation model allows multiple cannulations and can serve as a thoracic aortic surgery model. The cardiopulmonary bypass simulator provides crisis management experience. The porcine aortic valve replacement, mitral valve annuloplasty, and aortic root models are realistic and permit standardized training. The hilar dissection model is subject to variability of porcine anatomy and fragility of the vascular structures. The realistic esophageal anastomosis simulator presents various approaches to esophageal anastomosis. The exercise associated with the rigid bronchoscopy model is brief, and adding additional procedures should be considered. The tracheal resection, sleeve resection, and video-assisted thoracoscopic surgery lobectomy models are highly realistic and simulate advanced maneuvers. By providing the necessary tools, such as task trainers and assessment instruments, the Senior Tour may be one means to enhance simulation-based learning in cardiothoracic surgery. The Senior Tour members can provide regular programmatic evaluation and critical analyses to ensure that proposed simulators are of educational value. Published by Mosby, Inc.
Yun, Chun-Ho; Longenecker, Chris T; Chang, Hui-Ru; Mok, Greta S P; Sun, Jing-Yi; Liu, Chuan-Chuan; Kuo, Jen-Yuan; Hung, Chung-Lieh; Wu, Tung-Hsin; Yeh, Hung-I; Yang, Fei-Shih; Lee, Jason Jeun-Shenn; Hou, Charles Jia-Yin; Cury, Ricardo C; Bezerra, Hiram G
2016-01-01
To describe the relationship between a novel measurement of peri-arotic root fat and ultrasound measures of carotid artery remodeling. We studied 1492 consecutive subjects (mean age: 51.04 ± 8.97 years, 27% females) who underwent an annual cardiovascular risk survey in Taiwan. Peri-aortic root fat (PARF) was assessed by cardiac CT using three-dimensional (3D) volume assessment. Carotid artery morphology and remodeling were assessed by ultrasound. We explored the relationships between PARF volumes, cardiometabolic risk profiles and carotid morphology and remodeling. Mean PARF volume in current study was 20.8 ± 10.6 ml. PARF was positively correlated with measures of general adiposity, systemic inflammation, and several traditional cardiometabolic risk profiles (all p < 0.001) and successfully predicted metabolic syndrome (MetS) (AUROC: 0.75, 95%, confidence interval: 0.72-0.77). Higher PARF was independently associated with increased carotid artery intima-media thickness (IMT) (β-coef.: 0.08) and diameter (β-coef.: 0.08, both p < 0.05) after accounting for age, sex, BMI and other cardiovascular risk factors. The addition of PARF beyond metabolic syndrome components significantly provided incremental prediction value for abnormal IMT (ΔAUROC: 0.053, p = 0.0021). Peri-aortic root fat is associated with carotid IMT, even after adjustment for cardiometabolic risks, age and coronary atherosclerosis. Further research studies are warranted to identify the mediators of downstream pathophysiologic effects on carotid arteries by PARF and understand the mechanisms related to this correlation. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Chronic skin-specific inflammation promotes vascular inflammation and thrombosis.
Wang, Yunmei; Gao, Huiyun; Loyd, Candace M; Fu, Wen; Diaconu, Doina; Liu, Shijian; Cooper, Kevin D; McCormick, Thomas S; Simon, Daniel I; Ward, Nicole L
2012-08-01
Patients with psoriasis have systemic and vascular inflammation and are at increased risk for myocardial infarction, stroke, and cardiovascular death. However, the underlying mechanism(s) mediating the link between psoriasis and vascular disease is incompletely defined. This study sought to determine whether chronic skin-specific inflammation has the capacity to promote vascular inflammation and thrombosis. Using the KC-Tie2 doxycycline-repressible (Dox-off) murine model of psoriasiform skin disease, spontaneous aortic root inflammation was observed in 33% of KC-Tie2 compared with 0% of control mice by 12 months of age (P=0.04) and was characterized by the accumulation of macrophages, T lymphocytes, and B lymphocytes, as well as by reduced collagen content and increased elastin breaks. Importantly, aortic inflammation was preceded by increases in serum tumor necrosis factor-α, IL-17A, vascular endothelial growth factor, IL-12, monocyte chemotactic protein-1, and S100A8/A9, as well as splenic and circulating CD11b(+)Ly-6C(hi) pro-inflammatory monocytes. Doxycycline treatment of old mice with severe skin disease eliminated skin inflammation and the presence of aortic root lesion in 1-year-old KC-Tie2 animals. Given the bidirectional link between inflammation and thrombosis, arterial thrombosis was assessed in KC-Tie2 and control mice; mean time to occlusive thrombus formation was shortened by 64% (P=0.002) in KC-Tie2 animals; and doxycycline treatment returned thrombosis clotting times to that of control mice (P=0.69). These findings demonstrate that sustained skin-specific inflammation promotes aortic root inflammation and thrombosis and suggest that aggressive treatment of skin inflammation may attenuate pro-inflammatory and pro-thrombotic pathways that produce cardiovascular disease in psoriasis patients.
Hiratzka, Loren F; Creager, Mark A; Isselbacher, Eric M; Svensson, Lars G; Nishimura, Rick A; Bonow, Robert O; Guyton, Robert A; Sundt, Thoralf M; Halperin, Jonathan L; Levine, Glenn N; Anderson, Jeffrey L; Albert, Nancy M; Al-Khatib, Sana M; Birtcher, Kim K; Bozkurt, Biykem; Brindis, Ralph G; Cigarroa, Joaquin E; Curtis, Lesley H; Fleisher, Lee A; Gentile, Federico; Gidding, Samuel; Hlatky, Mark A; Ikonomidis, John; Joglar, José; Kovacs, Richard J; Ohman, E Magnus; Pressler, Susan J; Sellke, Frank W; Shen, Win-Kuang; Wijeysundera, Duminda N
2016-02-16
Two guidelines from the American College of Cardiology (ACC), the American Heart Association (AHA), and collaborating societies address the risk of aortic dissection in patients with bicuspid aortic valves and severe aortic enlargement: the "2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the Diagnosis and Management of Patients With Thoracic Aortic Disease" (Circulation. 2010;121:e266-e369) and the "2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease" (Circulation. 2014;129:e521-e643). However, the 2 guidelines differ with regard to the recommended threshold of aortic root or ascending aortic dilatation that would justify surgical intervention in patients with bicuspid aortic valves. The ACC and AHA therefore convened a subcommittee representing members of the 2 guideline writing committees to review the evidence, reach consensus, and draft a statement of clarification for both guidelines. This statement of clarification uses the ACC/AHA revised structure for delineating the Class of Recommendation and Level of Evidence to provide recommendations that replace those contained in Section 9.2.2.1 of the thoracic aortic disease guideline and Section 5.1.3 of the valvular heart disease guideline. © 2015 American College of Cardiology Foundation and American Heart Association, Inc.
Monozygotic twins with Marfan's syndrome and ascending aortic aneurysm.
Redruello, Héctor Jorge; Cianciulli, Tomas Francisco; Rostello, Eduardo Fernandez; Recalde, Barbara; Lax, Jorge Alberto; Picone, Victorio Próspero; Belforte, Sandro Mario; Prezioso, Horacio Alberto
2007-08-01
Marfan's syndrome is a hereditary connective tissue disease, in which cardiovascular abnormalities (especially aortic root dilatation) are the most important cause of morbidity and mortality. In this report, we describe two 24-year-old twins, with a history of surgery for lens subluxation and severe cardiovascular manifestations secondary to Marfan's syndrome. One of the twins suffered a type A aortic dissection, which required replacement of the ascending aorta, and the other twin had an aneurysmal dilatation of the ascending aorta (46mm) and was prescribed medical treatment with atenolol and periodic controls to detect the presence of a critical diameter (50mm) that would indicate the need for prophylactic surgery.
Kiefer, Philipp; Noack, Thilo; Seeburger, Joerg; Hoyer, Alexandro; Linke, Axel; Mangner, Norman; Lehmkuhl, Lukas; Mohr, Friedrich Wilhelm; Holzhey, David
2017-12-01
Transcatheter mitral valve implantation (TMVI) is still in its infancy and is mainly limited to valve-in-valve or valve-in-ring implantations. We present the early experience with TMVI for severe calcified native MV stenosis. Between January 2014 and June 2015, 6 of 11 patients screened (mean age, 77.4 ± 6.3 years; 66% men) with severe native mitral valve (MV) stenosis (mean gradient [Pmean], 11.1 ± 2.1 mm Hg; mean effective orifice area [EOA], 0.9 ± 0.12 cm 2 ) underwent transcatheter MV replacement at our institution as a bailout procedure. Conventional surgical procedures were denied in all patients because of severe annular calcification and extensive comorbidities (mean logistic EuroScore, 31.4% ± 8.3%). The Edwards SAPIEN 3 (29 mm) (Edwards Lifesciences, Irvine, CA) was used in all cases. Procedural access was transapical in 5 cases and concomitant to aortic valve replacement through the left atrium through a sternotomy in 1 case. Initial implantation was successful in 100% of the cases. Because of early migration, 1 patient needed a valve-in-valve procedure. Postoperative echocardiography showed no residual mitral regurgitation in 4 cases (66%) and mild regurgitation in 2 cases (34%). Mean gradients were reduced to 4.2 ± 0.6 mm Hg (mean EOA, 2.8 ± 0.4 cm 2) . No patient had a stroke during hospitalization, and 30-day mortality was seen in 1 patient (17%) resulting from pneumonia. TMV implantation using the SAPIEN 3 aortic prosthesis in patients with heavy annular calcification is feasible and represents a reasonable bailout option for inoperable patients. However, several limitations need to be considered in this special patient population. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.
Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K
2018-01-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.
Impaired Central Pulsatile Hemodynamics in Children and Adolescents With Marfan Syndrome.
Grillo, Andrea; Salvi, Paolo; Marelli, Susan; Gao, Lan; Salvi, Lucia; Faini, Andrea; Trifirò, Giuliana; Carretta, Renzo; Pini, Alessandro; Parati, Gianfranco
2017-11-07
Marfan syndrome is characterized by aortic root dilation, beginning in childhood. Data about aortic pulsatile hemodynamics and stiffness in pediatric age are currently lacking. In 51 young patients with Marfan syndrome (12.0±3.3 years), carotid tonometry was performed for the measurement of central pulse pressure, pulse pressure amplification, and aortic stiffness (carotid-femoral pulse wave velocity). Patients underwent an echocardiogram at baseline and at 1 year follow-up and a genetic evaluation. Pathogenetic fibrillin-1 mutations were classified between "dominant negative" and "haploinsufficient." The hemodynamic parameters of patients were compared with those of 80 sex, age, blood pressure, and heart-rate matched controls. Central pulse pressure was significantly higher (38.3±12.3 versus 33.6±7.8 mm Hg; P =0.009), and pulse pressure amplification was significantly reduced in Marfan than controls (17.9±15.3% versus 32.3±17.4%; P <0.0001). Pulse wave velocity was not significantly different between Marfan and controls (4.98±1.00 versus 4.75±0.67 m/s). In the Marfan group, central pulse pressure and pulse pressure amplification were independently associated with aortic diameter at the sinuses of Valsalva (respectively, β=0.371, P =0.010; β=-0.271, P =0.026). No significant difference in hemodynamic parameters was found according to fibrillin-1 genotype. Patients who increased aortic Z-scores at 1-year follow-up presented a higher central pulse pressure than the remaining (42.7±14.2 versus 32.3±5.9 mm Hg; P =0.004). Central pulse pressure and pulse pressure amplification were impaired in pediatric Marfan syndrome, and associated with aortic root diameters, whereas aortic pulse wave velocity was similar to that of a general pediatric population. An increased central pulse pressure was present among patients whose aortic dilatation worsened at 1-year follow-up. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Aortic Stenosis and Vascular Calcifications in Alkaptonuria
Hannoush, Hwaida; Introne, Wendy J.; Chen, Marcus Y.; Lee, Sook-Jin; O'Brien, Kevin; Suwannarat, Pim; Kayser, Michael A.; Gahl, William A.; Sachdev, Vandana
2011-01-01
Alkaptonuria is a rare metabolic disorder of tyrosine catabolism in which homogentisic acid (HGA) accumulates and is deposited throughout the spine, large joints, cardiovascular system, and various tissues throughout the body. In the cardiovascular system, pigment deposition has been described in the heart valves, endocardium, pericardium, aortic intima and coronary arteries. The prevalence of cardiovascular disease in patients with alkaptonuria varies in previous reports . We present a series of 76 consecutive adult patients with alkaptonuria who underwent transthoracic echocardiography between 2000 and 2009. A subgroup of 40 patients enrolled in a treatment study underwent non-contrast CT scans and these were assessed for vascular calcifications. Six of the 76 patients had aortic valve replacement. In the remaining 70 patients, 12 patients had aortic sclerosis and 7 patients had aortic stenosis. Unlike degenerative aortic valve disease, we found no correlation with standard cardiac risk factors. There was a modest association between the severity of aortic valve disease and joint involvement, however, we saw no correlation with urine HGA levels. Vascular calcifications were seen in the coronaries, cardiac valves, aortic root, descending aorta and iliac arteries. These findings suggest an important role for echocardiographic screening of alkaptonuria patients to detect valvular heart disease and cardiac CT to detect coronary artery calcifications. PMID:22100375
Aortic stenosis and vascular calcifications in alkaptonuria.
Hannoush, Hwaida; Introne, Wendy J; Chen, Marcus Y; Lee, Sook-Jin; O'Brien, Kevin; Suwannarat, Pim; Kayser, Michael A; Gahl, William A; Sachdev, Vandana
2012-02-01
Alkaptonuria is a rare metabolic disorder of tyrosine catabolism in which homogentisic acid (HGA) accumulates and is deposited throughout the spine, large joints, cardiovascular system, and various tissues throughout the body. In the cardiovascular system, pigment deposition has been described in the heart valves, endocardium, pericardium, aortic intima and coronary arteries. The prevalence of cardiovascular disease in patients with alkaptonuria varies in previous reports. We present a series of 76 consecutive adult patients with alkaptonuria who underwent transthoracic echocardiography between 2000 and 2009. A subgroup of 40 patients enrolled in a treatment study underwent non-contrast CT scans and these were assessed for vascular calcifications. Six of the 76 patients had aortic valve replacement. In the remaining 70 patients, 12 patients had aortic sclerosis and 7 patients had aortic stenosis. Unlike degenerative aortic valve disease, we found no correlation with standard cardiac risk factors. There was a modest association between the severity of aortic valve disease and joint involvement, however, we saw no correlation with urine HGA levels. Vascular calcifications were seen in the coronaries, cardiac valves, aortic root, descending aorta and iliac arteries. These findings suggest an important role for echocardiographic screening of alkaptonuria patients to detect valvular heart disease and cardiac CT to detect coronary artery calcifications. Published by Elsevier Inc.
Omar, Sabry; Moore, Tyler; Payne, Drew; Momeni, Parastoo; Mulkey, Zachary; Nugent, Kenneth
2014-01-01
We are reporting a case of familial thoracic aortic aneurysm and dissection in a 26-year-old man with no significant past medical history and a family history of dissecting aortic aneurysm in his mother at the age of 40. The patient presented with cough, shortness of breath, and chest pain. Chest X-ray showed bilateral pulmonary infiltrates. CT scan of the chest showed a dissection of the ascending aorta. The patient underwent aortic dissection repair and three months later he returned to our hospital with new complaints of back pain. CT angiography showed a new aortic dissection extending from the left carotid artery through the bifurcation and into the iliac arteries. The patient underwent replacement of the aortic root, ascending aorta, total aortic arch, and aortic valve. The patient recovered well postoperatively. Genetic studies of the patient and his children revealed no mutations in ACTA2, TGFBR1, TGFBR2, TGFB2, MYH11, MYLK, SMAD3, or FBN1. This case report focuses on a patient with familial TAAD and discusses the associated genetic loci and available screening methods. It is important to recognize potential cases of familial TAAD and understand the available screening methods since early diagnosis allows appropriate management of risk factors and treatment when necessary. PMID:25104961
... a general term which means inflammation of the aorta, the large blood vessel which transports blood from ... The aortic root is the part of the aorta which is directly connected to the left ventricle ( ...
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
Horstkotte, D; Körfer, R; Budde, T; Haerten, K; Schulte, H D; Bircks, W; Loogen, F
1983-05-01
Valve-related complications after Björk-Shiley mitral (n = 475), aortic (n = 424), or mitral-aortic implantation (n = 119) were compared to complications after St. Jude mitral (n = 173), aortic (n = 152), and St. Jude mitral and aortic (n = 63) replacements. The 1,018 consecutive patients with Björk-Shiley valves had been operated upon between 1974 and 1982, those with St. Jude valves between 1978 and 1982. All patients were placed on anticoagulant therapy with phenprocoumon early after operation and no significant intergroup differences in the effectiveness of the anticoagulant therapy were found. At a comparable follow-up time of approximately 23 months, 24 major thromboembolic episodes were observed after Björk-Shiley mitral (BSM) and 3 after St. Jude mitral valve implantation (SJM), corresponding to a thromboembolic rate of 2.82/100 patient years with BSM and 0.93/100 patient years with SJM. After aortic valve replacements, 1.93 events in 100 patient years occurred after Björk-Shiley aortic (BSA) and 0.73 after St. Jude aortic implantation (SJA). In patients with double valve replacements, these rates were 3.2 (BSM + BSA) and 0.88 (SJM + SJA), respectively. The cerebral vessels were involved in 52% and the arteries of the extremities in 22% of these major events. Six Björk-Shiley prostheses had to be replaced because of valve thrombosis. The overall incidence of severe hemorrhagic complications was 2.94/100 patient years in BSM and 1.79 in SJM. After aortic valve replacement, we found rates of 1.80/100 patient years (BSA) and 2.57/100 patient years (SJA), respectively. Intravascular hemolysis no longer seems to be a significant clinical problem. However, indications of red cell damage after heart valve replacement were significantly greater in patients with perivalvular leakage, valve thrombosis, or dysfunction than in those with normally functioning prostheses. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with concomitant perivalvular regurgitation (0.46%). One valve had to be replaced because of fracture of the outlet strut of a BSM prosthesis. Hemorrhage due to the anticoagulant treatment was thus the most frequent complication, without significant intergroup differences, while thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude implantation. This may lead to the consideration of a change in the prophylaxis of thrombus formations with the St. Jude valve, especially in aortic valve replacements with sinus rhythm.
Recent Developments in Minimally Invasive Cardiac Surgery: Evolution or Revolution?
Marullo, Antonino G M; Irace, Francesco G; Vitulli, Piergiusto; Peruzzi, Mariangela; Rose, David; D'Ascoli, Riccardo; Iaccarino, Alessandra; Pisani, Angelo; De Carlo, Carlotta; Mazzesi, Giuseppe; Barretta, Antonio; Greco, Ernesto
2015-01-01
Intraluminal aortic clamping has been achieved until now by means of a sophisticated device consisting of a three-lumen catheter named Endoclamp, which allows at the same time occlusion of the aorta, antegrade delivering of cardioplegia, and venting through the aortic root. This tool has shown important advantages allowing aortic occlusion and perfusate delivering without a direct contact with ascending aorta reducing meanwhile the risk of traumatic and/or iatrogenic injuries. Recently, a new device (Intraclude catheter) with the same characteristics and properties has been proposed and introduced in clinical practice. The aim of this paper is to investigate the differences between Endoclamp and Intraclude catheters and to analyze the advantages advocated by this new device for intraluminal aortic occlusion since it is noticeable as these new technological tools are gaining more and more attractiveness due to their appraised clinical efficacy.
Post-introduction observation of transcatheter aortic valve implantation in Galicia (Spain).
Varela-Lema, Leonor; Queiro-Verdes, Teresa; Baz-Alonso, José A; Cuenca-Castillo, José J; Durán-Muñoz, Darío; Gónzalez-Juanatey, José R; Herrera Noreña, José M; Iñiguez-Romo, Andrés; López-Otero, Diego; Pradas-Montilla, Gonzalo; Rubio-Álvarez, José; Salgado-Fernández, Jorge; Trillo Nouche, Ramiro; Vázquez-González, Nicolás; López-García, Marisa
2015-02-01
Transcatheter aortic valve implantation constitutes an example of a technology introduced into the Galician Health Care System basket and subjected to a post-introduction observational study after coverage. This paper aims to describe the process and results of this experience, illustrating the main challenges and opportunities in using these studies for supporting decision making. The study protocol was developed by a multidisciplinary team consisting of experts from the Galician HTA Agency (avalia-t), interventional cardiologists and cardiac surgeons. Together they agreed on the information that was relevant and feasible for collection, and planned the study design, data collection and analysis of results. During the 1-year recruitment period, 94 patients underwent percutaneous aortic valve replacement in the three authorized centres. Implantation rate and prosthesis models differed substantially across the centres. Overall, procedural success rate was 96.8% and hospital mortality was 7.4%. Complications during post-surgical admission were recorded in 40.4% of patients. Moderate residual aortic regurgitation was observed in 10% of patients, and the procedure was associated with a stroke rate of 3.3% at 30 days and 5.3% at 1 year. Post-introduction observation has made it feasible to determine the use of this procedure within the SERGAS context and has enabled the assessment of performance in real-life conditions. The proposed strategic actions and interventions have been drawn up based upon the collective judgement of a group of experienced professionals, and have served to establish recommendations on further research that would be required to optimize health benefits. © 2014 John Wiley & Sons, Ltd.
Haslach, Henry W; Siddiqui, Ahmed; Weerasooriya, Amanda; Nguyen, Ryan; Roshgadol, Jacob; Monforte, Noel; McMahon, Eileen
2018-03-01
This experimental study adopts a fracture mechanics strategy to investigate the mechanical cause of aortic dissection. Inflation of excised healthy bovine aortic rings with a cut longitudinal notch that extends into the media from the intima suggests that an intimal tear may propagate a nearly circumferential-longitudinal rupture surface that is similar to the delamination that occurs in aortic dissection. Radial and 45°-from-radial cut notch orientations, as seen in the thickness surface, produce similar circumferential crack propagation morphologies. Partial cut notches, whose longitudinal length is half the width of the ring, measure the influence of longitudinal material on crack propagation. Such specimens also produce circumferential cracks from the notch root that are visible in the thickness circumferential-radial plane, and often propagate a secondary crack from the base of the notch, visible in the intimal circumferential-longitudinal plane. Inflation of rings with pairs of cut notches demonstrates that a second notch modifies the propagation created in a specimen with a single notch. The circumferential crack propagation is likely a consequence of the laminar medial structure. These fracture surfaces are probably due to non-uniform circumferential shear deformation in the heterogeneous media as the aortic wall expands. The qualitative deformation morphology around the root of the cut notch during inflation is evidence for such shear deformation. The shear apparently results from relative slip in the circumferential direction of collagen fibers. The slip may produce shear in the longitudinal-circumferential plane between medial layers or in the radial-circumferential plane within a medial lamina in an idealized model. Circumferential crack propagation in the media is then a shear mechanical process that might be facilitated by disease of the tissue. An intimal tear of an apparently healthy aortic wall near the aortic arch is life-threatening because it may lead to full rupture or to wall dissection in which delamination of the medial layer extends around most of the aortic circumference. The mechanical events underlying dissection are not definitively established. This experimental fracture mechanics study provides evidence that shear rupture is the main mechanical process underlying aortic dissection. The commonly performed tensile strength tests of aortic tissue are not clinically useful to predict or describe aortic dissection. One implication of the study is that shear tests might produce more fruitful simple assessments of the aortic wall strength. A clinical implication is that when presented with an intimal tear, those who guide care might recommend steps to reduce the shear load on the aorta. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Hiratzka, Loren F; Creager, Mark A; Isselbacher, Eric M; Svensson, Lars G; Nishimura, Rick A; Bonow, Robert O; Guyton, Robert A; Sundt, Thoralf M
2016-04-01
Two guidelines from the American College of Cardiology (ACC), the American Heart Association (AHA), and collaborating societies address the risk of aortic dissection in patients with bicuspid aortic valves and severe aortic enlargement: The "2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the Diagnosis and Management of Patients With Thoracic Aortic Disease" (J Am Coll Cardiol. 2010;55:e27-130) and the "2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease" (J Am Coll Cardiol. 2014;63:e57-185). However, the 2 guidelines differ with regard to the recommended threshold of aortic root or ascending aortic dilatation that would justify surgical intervention in patients with bicuspid aortic valves. The ACC and AHA therefore convened a subcommittee representing members of the 2 guideline writing committees to review the evidence, reach consensus, and draft a statement of clarification for both guidelines. This statement of clarification uses the ACC/AHA revised structure for delineating the Class of Recommendation and Level of Evidence to provide recommendations that replace those contained in Section 9.2.2.1 of the thoracic aortic disease guideline and Section 5.1.3 of the valvular heart disease guideline. Copyright © 2016 American College of Cardiology Foundation and American Heart Association, Inc. Published by Elsevier Inc. All rights reserved.
Hiratzka, Loren F; Creager, Mark A; Isselbacher, Eric M; Svensson, Lars G; Nishimura, Rick A; Bonow, Robert O; Guyton, Robert A; Sundt, Thoralf M
2016-02-16
Two guidelines from the American College of Cardiology (ACC), the American Heart Association (AHA), and collaborating societies address the risk of aortic dissection in patients with bicuspid aortic valves and severe aortic enlargement: the "2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the Diagnosis and Management of Patients With Thoracic Aortic Disease" (J Am Coll Cardiol 2010;55:e27-130) and the "2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease" (J Am Coll Cardiol 2014;63:e57-185). However, the 2 guidelines differ with regard to the recommended threshold of aortic root or ascending aortic dilatation that would justify surgical intervention in patients with bicuspid aortic valves. The ACC and AHA therefore convened a subcommittee representing members of the 2 guideline writing committees to review the evidence, reach consensus, and draft a statement of clarification for both guidelines. This statement of clarification uses the ACC/AHA revised structure for delineating the Class of Recommendation and Level of Evidence to provide recommendations that replace those contained in Section 9.2.2.1 of the thoracic aortic disease guideline and Section 5.1.3 of the valvular heart disease guideline. Copyright © 2016 American College of Cardiology Foundation and American Heart Association, Inc. Published by Elsevier Inc. All rights reserved.
Development of an algorithm to plan and simulate a new interventional procedure.
Fujita, Buntaro; Kütting, Maximilian; Scholtz, Smita; Utzenrath, Marc; Hakim-Meibodi, Kavous; Paluszkiewicz, Lech; Schmitz, Christoph; Börgermann, Jochen; Gummert, Jan; Steinseifer, Ulrich; Ensminger, Stephan
2015-07-01
The number of implanted biological valves for treatment of valvular heart disease is growing and a percentage of these patients will eventually undergo a transcatheter valve-in-valve (ViV) procedure. Some of these patients will represent challenging cases. The aim of this study was to develop a feasible algorithm to plan and in vitro simulate a new interventional procedure to improve patient outcome. In addition to standard diagnostic routine, our algorithm includes 3D printing of the annulus, hydrodynamic measurements and high-speed analysis of leaflet kinematics after simulation of the procedure in different prosthesis positions as well as X-ray imaging of the most suitable valve position to create a 'blueprint' for the patient procedure. This algorithm was developed for a patient with a degenerated Perceval aortic sutureless prosthesis requiring a ViV procedure. Different ViV procedures were assessed in the algorithm and based on these results the best option for the patient was chosen. The actual procedure went exactly as planned with help of this algorithm. Here we have developed a new technically feasible algorithm simulating important aspects of a novel interventional procedure prior to the actual procedure. This algorithm can be applied to virtually all patients requiring a novel interventional procedure to help identify risks and find optimal parameters for prosthesis selection and placement in order to maximize safety for the patient. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Wan, W K; Campbell, G; Zhang, Z F; Hui, A J; Boughner, D R
2002-01-01
Although bioprosthetic heart valves offer the benefits of a natural opening and closing, better hemodynamics, and avoidance of life-long anticoagulant therapy, they nevertheless tend to fail in 10-15 years from tears and calcification. Several authors, including the present ones, have identified the rigid stent as a factor contributing to these failures. The ultimate solution is an artificial heart valve that has mechanical properties that allow it to move in conformity with the aortic root during the cardiac cycle, has superior hemodynamics, is nonthrombogenic, will last more than 20 years, and mitigates the need for anticoagulants. We have identified a polymer, polyvinyl alcohol (PVA) hydrogel, that has mechanical properties similar to soft tissue. The purpose of this research is to match the tensile properties of PVA to the porcine aortic root and to fabricate a stent prototype for a bioprosthetic heart valve with the use of the PVA hydrogel. Specimens of 15% w/w PVA were prepared by processing through 1-6 cycles of freezing (-20 degrees C) at 0.2 degrees C/min freeze rate and thawing (+20 degrees C) at different thawing rates (0.2 degrees C/min and 1 degrees C/min), for different holding times (1 and 6 h) at -20 degrees C. Subsequently tensile tests and stress-relaxation tests were conducted on the specimens. The different holding times at -20 degrees C demonstrated no difference in the result. The slower thawing rate improved the tensile properties but did not produce significant changes on the stress-relaxation properties. The nonlinear stress-strain curve for the PVA after the fourth freeze-thaw cycle matched the porcine aortic root within the physiological pressure range. The stress-relaxation curve for PVA also approximated the shape of the aortic root. The complex geometry of an artificial heart valve stent was successfully injection molded. These results, in combination with other preliminary findings for biocompatibility and fatigue behavior, suggest that PVA hydrogel is a promising biomaterial for implants, catheters, and artificial skin. Copyright 2002 Wiley Periodicals, Inc.
Gavrila, Dan; Li, Wei Gen; McCormick, Michael L.; Thomas, Manesh; Daugherty, Alan; Cassis, Lisa A.; Miller, Francis J.; Oberley, Larry W.; Dellsperger, Kevin C.; Weintraub, Neal L.
2014-01-01
Background Abdominal aortic aneurysms (AAAs) in humans are associated with locally increased oxidative stress and activity of NADPH oxidase. We investigated the hypothesis that vitamin E, an antioxidant with documented efficacy in mice, can attenuate AAA formation during angiotensin II (Ang II) infusion in apolipoprotein E–deficient mice. Methods and Results Six-month-old male apolipoprotein E–deficient mice were infused with Ang II at 1000 ng/kg per minute for 4 weeks via osmotic minipumps while consuming either a regular diet or a diet enriched with vitamin E (2 IU/g of diet). After 4 weeks, abdominal aortic weight and maximal diameter were determined, and aortic tissues were sectioned and examined using biochemical and histological techniques. Vitamin E attenuated formation of AAA, decreasing maximal aortic diameter by 24% and abdominal aortic weight by 34% (P<0.05, respectively). Importantly, animals treated with vitamin E showed a 44% reduction in the combined end point of fatal+nonfatal aortic rupture (P<0.05). Vitamin E also decreased aortic 8-isoprostane content (a marker of oxidative stress) and reduced both aortic macrophage infiltration and osteopontin expression (P<0.05, respectively). Vitamin E treatment had no significant effect on the extent of aortic root atherosclerosis, activation of matrix metalloproteinases 2 or 9, serum lipid profile, or systolic blood pressure. Conclusions Vitamin E ameliorates AAAs and reduces the combined end point of fatal+nonfatal aortic rupture in this animal model. These findings are consistent with the concept that oxidative stress plays a pivotal role in Ang II–driven AAA formation in hyperlipidemic mice. PMID:15933246
van Ooij, Pim; Markl, Michael; Collins, Jeremy D; Carr, James C; Rigsby, Cynthia; Bonow, Robert O; Malaisrie, S Chris; McCarthy, Patrick M; Fedak, Paul W M; Barker, Alex J
2017-09-13
Wall shear stress (WSS) is a stimulus for vessel wall remodeling. Differences in ascending aorta (AAo) hemodynamics have been reported between bicuspid aortic valve (BAV) and tricuspid aortic valve patients with aortic dilatation, but the confounding impact of aortic valve stenosis (AS) is unknown. Five hundred seventy-one subjects underwent 4-dimensional flow magnetic resonance imaging in the thoracic aorta (210 right-left BAV cusp fusions, 60 right-noncoronary BAV cusp fusions, 245 tricuspid aortic valve patients with aortic dilatation, and 56 healthy controls). There were 166 of 515 (32%) patients with AS. WSS atlases were created to quantify group-specific WSS patterns in the AAo as a function of AS severity. In BAV patients without AS, the different cusp fusion phenotypes resulted in distinct differences in eccentric WSS elevation: right-left BAV patients exhibited increased WSS by 9% to 34% ( P <0.001) at the aortic root and along the entire outer curvature of the AAo whereas right-noncoronary BAV patients showed 30% WSS increase ( P <0.001) at the distal portion of the AAo. WSS in tricuspid aortic valve patients with aortic dilatation patients with no AS was significantly reduced by 21% to 33% ( P <0.01) in 4 of 6 AAo regions. In all patient groups, mild, moderate, and severe AS resulted in a marked increase in regional WSS ( P <0.001). Moderate-to-severe AS further increased WSS magnitude and variability in the AAo. Differences between valve phenotypes were no longer apparent. AS significantly alters aortic hemodynamics and WSS independent of aortic valve phenotype and over-rides previously described flow patterns associated with BAV and tricuspid aortic valve with aortic dilatation. Severity of AS must be considered when investigating valve-mediated aortopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Shape-based diagnosis of the aortic valve
NASA Astrophysics Data System (ADS)
Ionasec, Razvan Ioan; Tsymbal, Alexey; Vitanovski, Dime; Georgescu, Bogdan; Zhou, S. Kevin; Navab, Nassir; Comaniciu, Dorin
2009-02-01
Disorders of the aortic valve represent a common cardiovascular disease and an important public-health problem worldwide. Pathological valves are currently determined from 2D images through elaborate qualitative evalu- ations and complex measurements, potentially inaccurate and tedious to acquire. This paper presents a novel diagnostic method, which identies diseased valves based on 3D geometrical models constructed from volumetric data. A parametric model, which includes relevant anatomic landmarks as well as the aortic root and lea ets, represents the morphology of the aortic valve. Recently developed robust segmentation methods are applied to estimate the patient specic model parameters from end-diastolic cardiac CT volumes. A discriminative distance function, learned from equivalence constraints in the product space of shape coordinates, determines the corresponding pathology class based on the shape information encoded by the model. Experiments on a heterogeneous set of 63 patients aected by various diseases demonstrated the performance of our method with 94% correctly classied valves.
Recent Developments in Minimally Invasive Cardiac Surgery: Evolution or Revolution?
Marullo, Antonino G. M.; Irace, Francesco G.; D'Ascoli, Riccardo; Iaccarino, Alessandra; Pisani, Angelo; De Carlo, Carlotta; Mazzesi, Giuseppe; Barretta, Antonio; Greco, Ernesto
2015-01-01
Intraluminal aortic clamping has been achieved until now by means of a sophisticated device consisting of a three-lumen catheter named Endoclamp, which allows at the same time occlusion of the aorta, antegrade delivering of cardioplegia, and venting through the aortic root. This tool has shown important advantages allowing aortic occlusion and perfusate delivering without a direct contact with ascending aorta reducing meanwhile the risk of traumatic and/or iatrogenic injuries. Recently, a new device (Intraclude catheter) with the same characteristics and properties has been proposed and introduced in clinical practice. The aim of this paper is to investigate the differences between Endoclamp and Intraclude catheters and to analyze the advantages advocated by this new device for intraluminal aortic occlusion since it is noticeable as these new technological tools are gaining more and more attractiveness due to their appraised clinical efficacy. PMID:26636099
Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.
Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph
2004-12-01
Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004
Iwamoto, Masako; Kono, Misaki; Kawamoto, Daisuke; Tomoyori, Hiroko; Sato, Masao; Imaizumi, Katsumi
2002-01-01
Walnut oil (WO) is a good source of alpha-linolenic acid. We compared the effects of WO and high-linoleic safflower oil (HLSO) on the serum lipid level and atherosclerosis development in male and female apolipoprotein (apo) E-deficient mice. The WO diet resulted in a higher level of serum cholesterol than with HLSO. Female mice fed on the WO diet had a greater lesion area in the aortic root than did those on the HLSO diet. There was no diet-dependent difference in the level of cholesterol and its oxidation products in the abdominal and thoracic aorta. These results suggest that the unpleasant effects of the WO diet on apo E-deficient mice may be attributable to alpha-linolenic acid.
O'Riordan, Aisling M; McGrath, Niamh; Sharif, Farhana; Murphy, Nuala P; Franklin, Orla; Lynch, Sally Ann; O'Grady, Michael J
2017-01-01
Haploinsufficiency of the insulin-like growth factor-1 receptor (IGF1R) gene on chromosome 15q26.3 is associated with impaired prenatal and postnatal growth, developmental delay, dysmorphic features and skeletal abnormalities. Terminal deletions of chromosome 15q26 arising more proximally may also be associated with congenital heart disease, epilepsy, diaphragmatic hernia and renal anomalies. We report three additional cases of 15q26 terminal deletions with novel features which may further expand the spectrum of this rarely reported contiguous gene syndrome. Phenotypic features including neonatal lymphedema, aplasia cutis congenita and aortic root dilatation have not been reported previously. Similarly, laboratory features of insulin-like growth factor 1 (IGF-1) resistance are described, including markedly elevated IGF-1 of up to +4.7 SDS. In one patient, the elevated IGF-1 declined over time and this coincided with a period of spontaneous growth acceleration. Deletions of 15q26 are a potential risk factor for aortic root dilatation, neonatal lymphedema and aplasia cutis in addition to causing growth restriction. What is Known: • Terminal deletions of chromosome 15q26 are associated with impaired prenatal and postnatal growth, developmental delay, dysmorphic features and skeletal abnormalities. What is New: • Neonatal lymphedema, aplasia cutis congenita and aortic root dilatation have not been previously described in 15q26 terminal deletions and may represent novel features. • IGF-1 levels may be increased up to 4.7 SDS.
NASA Astrophysics Data System (ADS)
Auricchio, F.; Conti, M.; Lefieux, A.; Morganti, S.; Reali, A.; Sardanelli, F.; Secchi, F.; Trimarchi, S.; Veneziani, A.
2014-10-01
The purpose of this study is to quantitatively evaluate the impact of endovascular repair on aortic hemodynamics. The study addresses the assessment of post-operative hemodynamic conditions of a real clinical case through patient-specific analysis, combining accurate medical image analysis and advanced computational fluid-dynamics (CFD). Although the main clinical concern was firstly directed to the endoluminal protrusion of the prosthesis, the CFD simulations have demonstrated that there are two other important areas where the local hemodynamics is impaired and a disturbed blood flow is present: the first one is the ostium of the subclavian artery, which is partially closed by the graft; the second one is the stenosis of the distal thoracic aorta. Besides the clinical relevance of these specific findings, this study highlights how CFD analyses allow to observe important flow effects resulting from the specific features of patient vessel geometries. Consequently, our results demonstrate the potential impact of computational biomechanics not only on the basic knowledge of physiopathology, but also on the clinical practice, thanks to a quantitative extraction of knowledge made possible by merging medical data and mathematical models.
Backer, Julie De; Braverman, Alan C
2018-05-01
Predominant cardiovascular manifestations in the spectrum of Heritable Thoracic Aortic Disease include by default aortic root aneurysms- and dissections, which may be associated with aortic valve disease. Mitral- and tricuspid valve prolapse are other commonly recognized features. Myocardial disease, characterized by heart failure and/or malignant arrhythmias has been reported in humans and in animal models harboring pathogenic variants in the Fibrillin1 gene. Description of clinical history of three cases from one family in Ghent (Belgium) and one family in St. Louis (US). We report on three cases from two families presenting end-stage heart failure (in two) and lethal arrhythmias associated with moderate left ventricular dilatation (in one). All three cases harbor a pathogenic variant in the SMAD3 gene, known to cause aneurysm osteoarthritis syndrome, Loeys-Dietz syndrome type 3 or isolated Heritable Thoracic Aortic Disease. These unusual presentations warrant awareness for myocardial disease in patients harboring pathogenic variants in genes causing Heritable Thoracic Aortic Disease and indicate the need for prospective studies in larger cohorts. © 2018 The Authors. Molecular Genetics & Genomic Medicine published by Wiley Periodicals, Inc.
McNally, Andrew; Madan, Ashish; Sucosky, Philippe
2017-01-01
The bicuspid aortic valve (BAV) is a major risk factor for secondary aortopathy such as aortic dilation. The heterogeneous BAV morphotypes [left-right-coronary cusp fusion (LR), right-non-coronary cusp fusion (RN), and left-non-coronary cusp fusion (LN)] are associated with different dilation patterns, suggesting a role for hemodynamics in BAV aortopathogenesis. However, assessment of this theory is still hampered by the limited knowledge of the hemodynamic abnormalities generated by the distinct BAV morphotypes. The objective of this study was to compare experimentally the hemodynamics of a normal (i.e., non-dilated) ascending aorta (AA) subjected to tricuspid aortic valve (TAV), LR-BAV, RN-BAV, and NL-BAV flow. Tissue BAVs reconstructed from porcine TAVs were subjected to physiologic pulsatile flow conditions in a left-heart simulator featuring a realistic aortic root and compliant aorta. Phase-locked particle image velocimetry experiments were carried out to characterize the flow in the aortic root and in the tubular AA in terms of jet skewness and displacement, as well as mean velocity, viscous shear stress and Reynolds shear stress fields. While all three BAVs generated skewed and asymmetrical orifice jets (up to 1.7- and 4.0-fold increase in flow angle and displacement, respectively, relative to the TAV at the sinotubular junction), the RN-BAV jet was out of the plane of observation. The LR- and NL-BAV exhibited a 71% increase in peak-systolic orifice jet velocity relative to the TAV, suggesting an inherent degree of stenosis in BAVs. While these two BAV morphotypes subjected the convexity of the aortic wall to viscous shear stress overloads (1.7-fold increase in maximum peak-systolic viscous shear stress relative to the TAV-AA), the affected sites were morphotype-dependent (LR-BAV: proximal AA, NL-BAV: distal AA). Lastly, the LR- and NL-BAV generated high degrees of turbulence in the AA (up to 2.3-fold increase in peak-systolic Reynolds shear stress relative to the TAV) that were sustained from peak systole throughout the deceleration phase. This in vitro study reveals substantial flow abnormalities (increased jet skewness, asymmetry, jet velocity, turbulence, and shear stress overloads) in non-dilated BAV aortas, which differ from those observed in dilated aortas but still coincide with aortic wall regions prone to dilation. PMID:28203207
Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M
2017-05-01
With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (<4%) inter-modality nonsignificant biases. Repeated measurements showed <10% measurements variability. The new 3D analysis was the more accurate and reproducible of the existing echocardiographic techniques. Novel semi-automated 3DTEE analysis software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.
Hemiarch Reconstruction Vs Clamped Aortic Anastomosis for Concomitant Ascending Aortic Aneurysm.
Sultan, Ibrahim; Bianco, Valentino; Yajzi, Ibrahim; Kilic, Arman; Dufendach, Keith; Cardounel, Arturo; Althouse, Andrew D; Masri, Ahmad; Navid, Forozan; Gleason, Thomas G
2018-05-03
Deep hypothermic circulatory arrest (DHCA) is often avoided in patients with concomitant ascending aortic pathology when treating other cardiac disease to avoid increased risk of morbidity and mortality. We hypothesized that the use of DHCA with retrograde cerebral perfusion (RCP) does not add incremental risk to ascending aortic replacement alone in the setting of concomitant cardiac surgery. 408 ascending aortic ± hemiarch replacements and aortic (root)/mitral/tricuspid valve(s), CABG, or MAZE procedures were performed for concomitant cardiac disease. DHCA with RCP was used for all hemiarch replacements or the ascending aorta was replaced with an aortic cross-clamp proximal to the innominate artery. Propensity-score matching was used to match similar ascending patients vs. hemiarch patients; the final propensity score matched patients on age, gender, BMI, previous heart surgery, pre-op aortic insufficiency, pre-op aortic stenosis, pre-op EF, and operative variables. Propensity-score matching yielded 116 pairs of Non-hemiarch patients vs. 116 hemiarch patients. Within the propensity-score matched cohort, there were no differences in postoperative stroke (1.7% vs. 3.4%, p = 0.41), new postoperative dialysis (6.0% vs. 5.2%, p = 0.78), postoperative renal insufficiency (27.6% vs. 19.8%, p = 0.16), 30-day mortality (2.6% vs. 3.4%, p = 0.701), or 1-year mortality (4.3% vs. 4.3%, p = 1.00) CONCLUSIONS: Hemiarch replacement using DHCA with RCP does not increase the risk of operative complications compared to a normothermic, clamped-distal aortic anastomosis, and therefore its use should not be limited when planning complex multi-procedural reconstructions during elective ascending thoracic aortic replacement with concomitant cardiac surgery. Copyright © 2018. Published by Elsevier Inc.
Merlocco, Anthony; Lacro, Ronald V; Gauvreau, Kimberlee; Rabideau, Nicole; Singh, Michael N; Prakash, Ashwin
2017-10-01
Aortic stiffness measured by cardiac magnetic resonance (CMR) in connective tissue disorder (CTD) patients has been previously shown to be abnormal and to be associated with adverse aortic outcomes. The rate of increase in aortic stiffness with normal aging has been previously described. However, longitudinal changes in aortic stiffness have not been characterized in CTD patients. We examined longitudinal changes in CMR-derived aortic stiffness in children and young adults with CTDs. A retrospective analysis of 50 children and young adults (median age, 20 years; range, 0.2 to 49; 40% < 18 years old) with a CTD, and with at least 2 CMR examinations (total 152 examinations) over a median duration of 3.9 (1 to 13.2) years was performed. Aortic stiffness measures (strain, distensibility, and β stiffness index) were calculated on each examination at the aortic root (AoR), ascending aorta, and descending aorta. Longitudinal changes in parameters were analyzed using linear mixed-effects models. Aortic strain and distensibility decreased with age, whereas the β stiffness index increased at all aortic segments. The average rates of decline in distensibility (x10 -3 mm Hg -1 per 10-year increase in age) were 0.7, 1.3, and 1 at the AoR, ascending aorta, and descending aorta, respectively. The rates of decline in distensibility were not associated with the rates of AoR dilation or surgical AoR replacement. In conclusion, on serial CMR measurements in children and young adults with CTDs, aortic stiffness progressively increased with age, with rates of change only slightly higher than those previously reported in healthy adults. Copyright © 2017 Elsevier Inc. All rights reserved.
Intra-Aortic Missile After Gunshot Wound to Chest: An Interesting Case of Traumatic Cardiac Injury.
Fraser, Charles D; Goeddel, Lee; Patel, Nishant D; Azoury, Said C; Grimm, Joshua C; Sheinberg, Rosanne B; Sciortino, Christopher M
2017-05-01
Missile embolus to the heart, although uncommon, is one of the most challenging scenarios in trauma. We describe a 36-year-old man who presented with a gunshot wound to the left chest and a chest x-ray revealing a foreign body in the mediastinum. A median sternotomy was performed and an injury to the left ventricle was identified. After intraoperative echocardiography and fluoroscopy confirmed a foreign body in the aortic root, cardiopulmonary bypass was implemented. A bullet was retrieved from the noncoronary sinus of the aortic valve. Injuries to the anterior leaflet of the mitral valve and left ventricle were repaired. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Thourani, Vinod H; Forcillo, Jessica; Szeto, Wilson Y; Kodali, Susheel K; Blackstone, Eugene H; Lowry, Ashley M; Semple, Marie; Rajeswaran, Jeevanantham; Makkar, Raj R; Williams, Mathew R; Bavaria, Joseph E; Herrmann, Howard C; Maniar, Hersh S; Babaliaros, Vasilis C; Smith, Craig R; Trento, Alfredo; Corso, Paul J; Pichard, Augusto D; Miller, D Craig; Svensson, Lars G; Kapadia, Samir; Ailawadi, Gorav; Suri, Rakesh M; Greason, Kevin L; Hahn, Rebecca T; Jaber, Wael A; Alu, Maria C; Leon, Martin B; Mack, Michael J
2018-05-01
The Placement of Aortic Transcatheter Valves 2A (PARTNER-2A) randomized trial compared outcomes of transfemoral transcatheter and surgical aortic valve replacement (SAVR) in intermediate-risk patients with severe aortic stenosis. The purpose of the present study was to perform an in-depth analysis of outcomes after SAVR in the PARTNER-2A trial. From January 2012 to January 2014, 937 patients underwent SAVR at 57 centers. Mean age was 82 ± 6.7 years and 55% were men. Less-invasive operations were performed in 140 patients (15%) and concomitant procedures in 198 patients (21%). Major outcomes and echocardiograms were adjudicated by an independent events committee. Follow-up was 94% complete to 2 years. Operative mortality was 4.1% (n = 38, Society of Thoracic Surgeons predicted risk of mortality: 5.2% ± 2.3%), observed to expected ratio (O/E) was 0.8, and in-hospital stroke was 5.4% (n = 51), twice expected. Aortic clamp and bypass times were 75 ± 30 minutes and 104 ± 46 minutes, respectively. Patients having severe prosthesis-patient mismatch (n = 260, 33%) had similar survival to patients without (p > 0.9), as did patients undergoing less-invasive SAVR (p = 0.3). Risk factors for death included cachexia (p = 0.004), tricuspid regurgitation (p = 0.01), coronary artery disease (p = 0.02), preoperative atrial fibrillation (p = 0.001), higher white blood cell count (p < 0.0001), and lower hemoglobin (p = 0.0002). In this adjudicated prospective study, SAVR in intermediate-risk patients had excellent results at 2 years. However, there were more in-hospital strokes than expected, most likely attributable to mandatory neurologic assessment after the procedure. No pronounced structural valve deterioration was found during 2-year follow-up. Continued long-term surveillance remains important. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Single-centre experience with the frozen elephant trunk technique in 251 patients over 15 years.
Shrestha, Malakh; Martens, Andreas; Kaufeld, Tim; Beckmann, Erik; Bertele, Sebastian; Krueger, Heike; Neuser, Julia; Fleissner, Felix; Ius, Fabio; Abd Alhadi, Firas; Hanke, Jasmin; Schmitto, Jan D; Cebotari, Serghei; Karck, Matthias; Haverich, Axel; Chavan, Ajay
2017-11-01
Our goal was to present our 15-year experience (2001-2015) with the frozen elephant trunk (FET) technique. A total of 251 patients (82 with aortic aneurysms, 96 with acute aortic dissection type A, 4 with acute type B dissections, 52 with chronic aortic dissection type A, 17 with chronic type B dissection and 67 redo cases) underwent FET implantation with either the custom-made Chavan-Haverich (n = 66), the Jotec E-vita (n = 31) or the Vascutek Thoraflex hybrid (n = 154) prosthesis. The cases were assigned to an early period (2001-2011) and a contemporary period (2012-present). Mean cardiopulmonary bypass time, aortic cross-clamp time, circulatory arrest time and selective antegrade cerebral perfusion time were 241 ± 72, 125 ± 59, 56 ± 30 and 81 ± 34 min, respectively. Incidence of rethoracotomy for bleeding, stroke, spinal cord injury, prolonged ventilatory support (>96 h) and long-term dialysis were 18, 14, 2, 24 and 2%, respectively. The in-hospital mortality rate was 11% (in acute aortic dissection type A, 12%). Of the 2 patients with graft infections, 1 died and the other had a protracted hospital stay. There were 49 second-stage procedures in the downstream aorta: either open surgical [n = 25 (thoraco-abdominal, n = 15; descending, n = 6; infrarenal, n = 4)] or transfemoral endovascular (n = 23). Elective thoracic endovascular aneurysm repair R implantation was successful in all 23 cases. FET results are comparable with those of the published results of the conventional elephant trunk technique. FET is an ideal landing zone for subsequent transfemoral endovascular completion. Patients with graft infections may have dismal results. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Kesavan, R; Chandel, S; Upadhyay, S; Bendre, R; Ganugula, R; Potunuru, U R; Giri, H; Sahu, G; Kumar, P Uday; Reddy, G Bhanuprakash; Joksic, G; Bera, A K; Dixit, Madhulika
2016-04-01
Studies suggest that Gentiana lutea (GL), and its component isovitexin, may exhibit anti-atherosclerotic properties. In this study we sought to investigate the protective mechanism of GL aqueous root extract and isovitexin on endothelial inflammation, smooth muscle cell migation, and on the onset and progression of atherosclerosis in streptozotocin (STZ)-induced diabetic rats. Our results show that both GL extract and isovitexin, block leukocyte adhesion and generation of reactive oxygen species in human umbilical vein endothelial cells (HUVECs) and rat aortic smooth muscle cells (RASMCs), following TNF-alpha and platelet derived growth factor-BB (PDGF-BB) challenges respectively. Both the extract and isovitexin blocked TNF-α induced expression of ICAM-1 and VCAM-1 in HUVECs. PDGF-BB induced migration of RASMCs and phospholipase C-γ activation, were also abrogated by GL extract and isovitexin. Fura-2 based ratiometric measurements demonstrated that, both the extact, and isovitexin, inhibit PDGF-BB mediated intracellular calcium rise in RASMCs. Supplementation of regular diet with 2% GL root powder for STZ rats, reduced total cholesterol in blood. Oil Red O staining demonstrated decreased lipid accumulation in aortic wall of diabetic animals upon treatment with GL. Medial thickness and deposition of collagen in the aortic segment of diabetic rats were also reduced upon supplementation. Immunohistochemistry demonstrated reduced expression of vascular cell adhesion molecule-1 (VCAM-1), inducible nitric oxide synthase (iNOS), and vascular endothelial cadherin (VE-cadherin) in aortic segments of diabetic rats following GL treatment. Thus, our results support that GL root extract/powder and isovitexin exhibit anti-atherosclerotic activities. Copyright © 2016 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.
Yoneyama, Fumiya; Okamura, Toru; Harada, Yorikazu; Okita, Yutaka
2018-02-01
A 13-year-old male presented with neoaortic root dilatation and severe aortic valve regurgitation 13 years following an arterial switch operation. The valve cusps were unbalanced due to an enlarged non-coronary cusp. A valve-sparing reimplantation with a cusp plication was performed which resulted in a competent valve with trivial regurgitation. Thus, even in an unbalanced cusp, valve-sparing reimplantation can be used for neoaortic root dilatation and valve regurgitation after an arterial switch operation. © 2018 Wiley Periodicals, Inc.
One-year outcomes after rapid-deployment aortic valve replacement.
Young, Christopher; Laufer, Günther; Kocher, Alfred; Solinas, Marco; Alamanni, Francesco; Polvani, Gianluca; Podesser, Bruno K; Aramendi, Jose Ignacio; Arribas, Jose; Bouchot, Olivier; Livi, Ugolino; Massetti, Massimo; Terp, Kim; Giot, Christophe; Glauber, Mattia
2018-02-01
The goals of rapid-deployment aortic valve replacement include facilitation of minimally invasive surgery and reduced aortic crossclamp time. We report the short-term outcomes of a series of 493 patients undergoing rapid-deployment aortic valve replacement with the EDWARDS INTUITY valve system (Edwards Lifesciences, LLC, Irvine, Calif). Assessing Standard oF Care and Clinical Outcomes UsiNg the EDWARDS INTUITY VAlve SysTem in a European multI-center, Active, pOst-market surveillaNce Study was a prospective, multicenter (n = 26) European registry designed to evaluate the safety and performance of the valve system. During rapid-deployment aortic valve replacement, device technical success and crossclamp time were assessed. Procedural outcomes, hemodynamic performance, and various adverse events and clinical outcomes were evaluated up to 2 years. Between 2012 and 2014, 493 of 517 enrolled patients successfully received implants with the study valve (95.4% technical success). Mean crossclamp times for 163 full sternotomies, 128 mini-upper sternotomies, and 36 right anterior thoracotomies isolated aortic valve replacements were 47.3, 52.0, and 73.3 minutes, respectively. Mean follow-up was 1.8 years, with 870 total patient-years of follow-up. Mean effective orifice area increased from 0.72 (baseline) to 1.88 cm 2 , and mean pressure gradient decreased from 47.6 to 9.6 mm Hg (1 year). Mean effective orifice area index increased (0.39-1.01 cm 2 /m 2 ), and 28 of 287 patients (9.8%) exhibited severe prosthesis-patient mismatch at 1 year. After 1 year, 68.1% and 21.7% of patients were in New York Heart Association class I and II, respectively. Freedom from death, major bleeding, major perivalvular leak, reoperation, and device explant at 1 year were 0.935, 0.939, 0.976, 0.975, and 0.983, respectively. These results demonstrate commendable safety and performance of the test valve system over the short term in a broad European setting. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
[Aortic infective endocarditis: Value of surgery. About 48 cases].
Tribak, M; Konaté, M; Elhassani, A; Mahfoudi, L; Jaabari, I; Elkenassi, F; Boutayeb, A; Lachhab, F; Filal, J; Maghraoui, A; Bensouda, A; Marmade, L; Moughil, S
2016-02-01
Infective endocarditis (IE) is a serious disease whose prognosis depends on early management. Aortic location is characterized by its evolution toward myocardial failure and the high number of complications reasons for early surgery. To compare the short- and mid-terms results of surgery for aortic infective endocarditis (IE) in the active phase and the healed phase. We analyzed retrospectively the data of 48 consecutive patients operated for aortic infective endocarditis between January 2000 and January 2012. The data on operative mortality, morbidity and major cardiovascular events (mortality, recurrent endocarditis, reintervention, and stroke) were analyzed. Twenty-three patients (48%) underwent surgery during the active phase (group I), 19 on native and 4 on prosthetic valves, and 25 patients (52%) were operated during healed endocarditis (group II) only on native valve. Mean age was 39 years (12-81) with a male predominance (83%). Rheumatic valvular disease was the main etiology of underlying valvular disease in both groups (85%). The clinical feature was dominated by signs of cardiogenic shock in group I and dyspnea exertion stage III-IV NYHA in group II. Streptococcus and Staphylococcus germs were most frequently encountered. Indication for surgery was heart failure in group I, it was related to the symptoms, the severity of valvular disease and its impact on the left ventricle in group II. An aortic valve replacement with a mechanical prosthesis was performed in the majority of cases (83%). Postoperative mortality concerned only one patient in group I. Twenty-one patients (44%) were followed for a mean of 30 months (1-72). One patient in group II died following cerebral hemorrhagic stroke related to accident with vitamin K antagonist. In both groups, there was an improvement in the functional class. No recurrence of endocarditis was noted in both groups during follow-up. The prognosis of infective endocarditis of the aortic valve is severe due to the fast progression to heart failure. Early medical and surgical approach provides good results on morbidity and mortality in the short- and mid-terms. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Aortic Root Reconstruction with a New Dacron Graft Featuring Prefabricated Coronary Side Branches
Calcaterra, Domenico; Jazayeri, Mohammad-Ali; Turek, Joseph W.; Parekh, Kalpaj R.; Bashir, Mohammad; Karam, Karam; Farivar, Robert S.
2017-01-01
Background Coronary button reimplantation can represent a technical challenge of aortic root reconstruction that can be associated with significant morbidity and mortality. With the goal of simplifying coronary reimplantation and reducing the incidence of related complications, we designed a new Dacron graft with prefabricated coronary branches to minimize coronary artery mobilization and prevent the potential mechanical complications of reattachment to the body of the graft. Methods Between June 2010 and May 2012, we implanted the graft in eight patients (six males, two females) ranging in age from 42-68 years (mean, 54 years). Six procedures were modified Bentall reconstructions, and two procedures were valve-sparing root replacements using the reimplantation technique. Results There were no complications and no morbidity or mortality related to coronary reattachment. All patients were alive and doing well at a mean follow-up of 26 months (range, 17-38 months). At an extended mean follow-up of 42 months (range, 25-56 months), one patient died of stroke-related complications. No radiologic or clinical evidence of impairment of coronary perfusion was identified in any patient. Conclusions The use of this new graft model may simplify the technique of root reconstruction and potentially lower the incidence of mechanical complications related to coronary button reimplantation. PMID:28868309
Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf
2013-05-01
The study aimed to evaluate 1-year outcomes of the multicentre PREVAIL transapical (TA) study of TA-aortic valve implantation (AVI) in high-risk patients. From September 2009 to August 2010, a total of 150 patients, aged 81.6 ± 5.8 years, 40.7% female, were included at 12 European TA-AVI experienced sites. Patients received 23 (n = 36), 26 (n = 57) and 29 mm (n = 57) second-generation SAPIEN XT™ (Edwards Lifesciences, Irvine, CA, USA) valves. The mean logistic EuroSCORE was 24.3 ± 7.0, and mean Society Thoracic Surgeons score was 7.5 ± 4.4%. Survival was 91.3% at 30 days and 77.9% at 1 year. Subgroup analysis revealed survivals of 91.7/88.9, 86.0/70.2, 96.55/91.2% for patients receiving 23-, 26- and 29-mm valves at 30 days and at 1 year, respectively. Transthoracic echocardiography revealed preserved left ventricular ejection fraction and low gradients. Aortic incompetence was none in 41/48, trace 30/36, mild 22/12 and moderate in 7/4% at discharge and 1 year. Walking distance increased from 221 (postimplant) to 284 m (at 1 year, P = 0.0004). Three patients required reoperation due to increasing aortic incompetence during follow-up. Causes of mortality at 1 year were cardiac (n = 7), stroke (n = 1) and others (n = 5). The European PREVAIL multicentre trial demonstrates good functionality and good outcomes for TA-AVI using the second-generation SAPIEN XT prosthesis and the ASCENDRA-II delivery system. The 29-mm SAPIEN XT valve was successfully introduced and showed excellent results.
Guedes, Marco Antonio Vieira; Pomerantzeff, Pablo Maria Alberto; Brandão, Carlos Manuel de Almeida; Vieira, Marcelo Luiz Campos; Grinberg, Max; Stolf, Noedir Antonio Groppo
2010-01-01
The right anterolateral thoracotomy is an alternative technique for surgical approach of mitral valve. In these cases, femoral-femoral bypass still has been used, rising occurrence of complications related to femoral cannulation. Describe the technique and results of mitral valve treatment by right anterolateral thoracotomy using aortic cannulation for cardiac pulmonary bypass (CPB). From 1983 e 2008, 100 consecutive female patients, with average age 35 ±13 years, 96 (96%) underwent mitral valve surgical treatment in the Heart Institute of São Paulo. A right anterolateral thoracotomy approach associated with aortic cannulation was used for CPB. Eighty (80%) patients had rheumatic disease and 84 (84%) patients presented functional class III or IV. Were performed 45 (45%) comissurotomies, 38 (38%) valve repairs, 7(7%) mitral valve replacements, seven (7%) recomissurotomies and three (3%) prosthesis replacement. Sparing surgery was performed in 90 (90%) patients. The average CPB and clamp time were 57 ± 27 min e 39 ± 19 min, respectively. There were no in-hospital death, reoperation due to bleeding and convertion to sternotomy. Introperative complications were related to heart harvest (5%), especially in reoperations (3%). The most important complications in postoperative period were related to pulmonary system (11%), followed by atrial fibrilation (10%) but without major systemic repercussions. The mean inhospital length of stay was 8 ± 3 days. Follow-up was 6.038 patients/month. Actuarial survival was 98.0 ± 1.9% and freedom from reoperation was 81.4 ± 7.8% in 180 months. The right anterolateral thoracotomy associated with aortic cannulation in mitral valve surgery is a simple technique, reproducible and safety.
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside
Saxon, John T; Allen, Keith B; Cohen, David J
2018-01-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832
[Analysis of vascular complications of IABP therapy in open-heart surgery patients 1999-2004].
Kovács, Endre; Becker, Dávid; Daróczi, László; Gálfy, Ildikó; Hüttl, Tivadar; Laczkó, Agnes; Paukovits, Tamas; Vargha, Péter; Szabolcs, Zoltán
2006-04-01
Intraaortic balloon pump (IABP) is being used in cardiac surgery in an increased ratio. IABP therapy involves considerable risk, mainly vascular complications, postoperative bleeding and infection can represent danger. Between 1999 and 2004 out of 4443 open heart surgery operations we have performed intraaortic balloon pump treatment in case of 75 patients. The mean age was 64 years, 23 patients had diabetes mellitus, 47 patients had hypertension, 20 patients had peripheral vascular disease as well. We performed IABP therapy most frequently during isolated coronary bypass operations (42 cases), but also combined operations (implantation of valve prosthesis + coronary bypass) represent a significant part (implantation of aortic valve prosthesis + CABG: 5 cases, implantation of mitral valve prosthesis + CABG: 8 cases). Vascular complications occurred in 10 cases--13.3%--out of 75 patients, including 7 fatal ones. Three cases are due to the IABP treatment itself: Crush syndrome was developed leading to the loss of the patient. Applying the multiple logistic regression model we have examined the effect of the following factors on the occurrence of vascular complications: gender, age, body surface, accompanying diseases (hypertension, diabetes, peripheral vascular disease), the method and timing of insertion. Peripheral vascular disease (p < 0.005) and hypertension (p = 0.01) represent independent risk factors regarding the occurrence of complications. Having performed chi-square test we have not identified significant correlations between mortality and vascular complications. In case of prevailing peripheral vascular disease, the application of alternative insertion techniques--via the ascending aorta, the axillary artery--are recommended.
Dyamenahalli, Umesh; Abraham, Boban; Fontenot, Eudice; Prasad, Vinay; Imamura, Michiaki
2007-01-01
We report the aneurysmal dilation of the ascending aorta and the main pulmonary artery in 2 children with Kabuki syndrome. In 1 patient, there was progressive aneurysmal dilation of the ascending aorta necessitating aortoplasty. Histologic examination of the resected aorta revealed disrupted and fragmented elastic fibers in the medial layer, along with mucinous degeneration of the aortic wall. This is the first recognition and report of these findings as part of the Kabuki syndrome.
``Smart'' baroreception along the aortic arch, with reference to essential hypertension
NASA Astrophysics Data System (ADS)
Kember, G. C.; Zamir, M.; Armour, J. A.
2004-11-01
Beat-to-beat regulation of heart rate is dependent upon sensing of local stretching or local “disortion” by aortic baroreceptors. Distortions of the aortic wall are due mainly to left ventricular output and to reflected waves arising from the arterial tree. Distortions are generally believed to be useful in cardiac control since stretch receptors or aortic baroreceptors embedded in the adventitia of the aortic wall, transduce the distortions to cardiovascular neural reflex pathways responsible for beat-to-beat regulation of heart rate. Aortic neuroanatomy studies have also found a continuous strip of mechanosensory neurites spread along the aortic inner arch. Although their purpose is now unknown, such a combined sensing capacity would allow measurement of the space and time dependence of inner arch wall distortions due, among other things, to traveling waves associated with pulsatile flow in an elastic tube. We call this sensing capability-“smart baroreception.” In this paper we use an arterial tree model to show that the cumulative effects of wave reflections, from many sites far downstream, have a surprisingly pronounced effect on the pressure distribution in the root segment of the tree. By this mechanism global hemodynamics can be focused by wave reflections back to the aortic arch, where they can rapidly impact cardiac control via smart baroreception. Such sensing is likely important to maintain efficient heart function. However, alterations in the arterial tree due to aging and other natural processes can lead in such a system to altered cardiac control and essential hypertension.
Qian, Zhen; Wang, Kan; Liu, Shizhen; Zhou, Xiao; Rajagopal, Vivek; Meduri, Christopher; Kauten, James R; Chang, Yung-Hang; Wu, Changsheng; Zhang, Chuck; Wang, Ben; Vannan, Mani A
2017-07-01
This study aimed to develop a procedure simulation platform for in vitro transcatheter aortic valve replacement (TAVR) using patient-specific 3-dimensional (3D) printed tissue-mimicking phantoms. We investigated the feasibility of using these 3D printed phantoms to quantitatively predict the occurrence, severity, and location of any degree of post-TAVR paravalvular leaks (PVL). We have previously shown that metamaterial 3D printing technique can be used to create patient-specific phantoms that mimic the mechanical properties of biological tissue. This may have applications in procedural planning for cardiovascular interventions. This retrospective study looked at 18 patients who underwent TAVR. Patient-specific aortic root phantoms were created using the tissue-mimicking 3D printing technique using pre-TAVR computed tomography. The CoreValve (self-expanding valve) prostheses were deployed in the phantoms to simulate the TAVR procedure, from which post-TAVR aortic root strain was quantified in vitro. A novel index, the annular bulge index, was measured to assess the post-TAVR annular strain unevenness in the phantoms. We tested the comparative predictive value of the bulge index and other known predictors of post-TAVR PVL. The maximum annular bulge index was significantly different among patient subgroups that had no PVL, trace-to-mild PVL, and moderate-to-severe PVL (p = 0.001). Compared with other known PVL predictors, bulge index was the only significant predictor of moderate-severe PVL (area under the curve = 95%; p < 0.0001). Also, in 12 patients with post-TAVR PVL, the annular bulge index predicted the major PVL location in 9 patients (accuracy = 75%). In this proof-of-concept study, we have demonstrated the feasibility of using 3D printed tissue-mimicking phantoms to quantitatively assess the post-TAVR aortic root strain in vitro. A novel indicator of the post-TAVR annular strain unevenness, the annular bulge index, outperformed the other established variables and achieved a high level of accuracy in predicting post-TAVR PVL, in terms of its occurrence, severity, and location. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Ascending Aortic Stenting for Acute Supraaortic Stenosis From Graft Collapse.
Lader, Joshua M; Smith, Deane E; Staniloae, Cezar; Fallahi, Arzhang; Iqbal, Sohah N; Galloway, Aubrey C; Williams, Mathew R
2018-06-01
A 78-year-old man with remote type-A dissection presented with acute-onset dyspnea. Twenty-two years prior, treatment for his aortic disease required replacement of ascending and arch aneurysms with a polyester graft (Dacron) using the graft inclusion technique. He presented currently in cardiogenic shock. Echocardiography demonstrated new severe hypokinesis of all apical segments. Left-heart catheterization revealed a 120 mm Hg intragraft gradient. Computed tomography arteriography was unrevealing, but intraaortic ultrasound demonstrated critical intragraft stenosis. A balloon expandable stent (Palmaz stent, Cordis, Milpitas, CA) was deployed in the stenotic region with gradient resolution. The patient later underwent aortic root replacement and ascending aneurysm repair (Bio-Bentall technique) and is doing well at 24 months. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto
2016-11-01
Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented
Transcatheter aortic-valve implantation with one single minimal contrast media injection.
Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian
2015-06-01
Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.
Aortic root segmentation in 4D transesophageal echocardiography
NASA Astrophysics Data System (ADS)
Chechani, Shubham; Suresh, Rahul; Patwardhan, Kedar A.
2018-02-01
The Aortic Valve (AV) is an important anatomical structure which lies on the left side of the human heart. The AV regulates the flow of oxygenated blood from the Left Ventricle (LV) to the rest of the body through aorta. Pathologies associated with the AV manifest themselves in structural and functional abnormalities of the valve. Clinical management of pathologies often requires repair, reconstruction or even replacement of the valve through surgical intervention. Assessment of these pathologies as well as determination of specific intervention procedure requires quantitative evaluation of the valvular anatomy. 4D (3D + t) Transesophageal Echocardiography (TEE) is a widely used imaging technique that clinicians use for quantitative assessment of cardiac structures. However, manual quantification of 3D structures is complex, time consuming and suffers from inter-observer variability. Towards this goal, we present a semiautomated approach for segmentation of the aortic root (AR) structure. Our approach requires user-initialized landmarks in two reference frames to provide AR segmentation for full cardiac cycle. We use `coarse-to-fine' B-spline Explicit Active Surface (BEAS) for AR segmentation and Masked Normalized Cross Correlation (NCC) method for AR tracking. Our method results in approximately 0.51 mm average localization error in comparison with ground truth annotation performed by clinical experts on 10 real patient cases (139 3D volumes).
Cheng, Zhuo; Kidher, Emaddin; Jarral, Omar A; O'Regan, Declan P; Wood, Nigel B; Athanasiou, Thanos; Xu, Xiao Yun
2016-05-01
This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.
Testai, Lara; Chericoni, Silvio; Calderone, Vincenzo; Nencioni, Giulia; Nieri, Paola; Morelli, Ivano; Martinotti, Enrica
2002-06-01
Urtica dioica (Urticaceae) is a plant principally used in the traditional medicine of oriental Marocco as antihypertensive remedy (J. Ethnopharmacol., 58 (1997), 45). The aim of this work was to evaluate a possible direct cardiovascular action of the plant and to investigate its mechanism of action. In aortic preparations with intact and functional endothelial layer, pre-contracted with KCl 20 mM or norepinephrine 3 microM, the crude aqueous and methanolic extracts of the plant roots, as well as purified fractions elicited a vasodilator action. Nevertheless, the vasodilator activity was not present in aortic rings without endothelial layer. In aortic rings with intact endothelial layer, the vasorelaxing effect was abolished by L-NAME, a NO-biosynthesis inhibitor, and ODQ, a guanylate cyclase inhibitor. Furthermore, potassium channel blockers (TEA, 4-aminopyridine, quinine, but not glybenclamide) antagonized the vasodilator action of the purified fraction F1W of U. dioica. The same fraction produced a marked decrease of inotropic activity, in spontaneously beating atria of guinea-pig, and a marked, but transient, hypotensive activity on the blood pressure of anaesthetized rats. It is concluded that U. dioica can produce hypotensive responses, through a vasorelaxing effect mediated by the release of endothelial nitric oxide and the opening of potassium channels, and through a negative inotropic action.
Igondjo-Tchen, S; Pagès, N; Bac, P; Godeau, G; Durlach, J
2003-03-01
The medical management of Marfan Syndrome (MFS) mainly relies on early prevention of the aortic complications. Hemodynamic treatments try to diminish the forcefulness of cardiac contractions and to reduce blood pressure: for example long term administration of propranolol may significantly reduce the rate of increase in aortic ratio (aortic diameter/expected aortic diameter). Retardation of aortic dilatation may be most often observed by early treatment started when the baseline end-diastolic aortic root diameter is < 40 mm. It seems better to use beta-blockers without intrinsic sympathomimetic activity. Successful acceptance of beta-blockers may be limited by side-effects, but the efficiency of alternative hypotensive agents (calcium channel inhibitors, ACE inhibitors) is not yet validated. Gene therapy might constitute an etiologic specific treatment of MFS. FBN1-RZ1 hammerhead antisense ribozyme is able to suppress expression of the mutant FBN1 allele. The use of ribozymes as systemic therapeutic agents will depend on efficient delivery to its target, but the various proposed vectors raise yet unsolved problems. A hydrogel angioplasty balloon might be a possible vector for delivering an antisense ribozyme in the aortic wall specifically. Ribozymes--as deoxyribonucleotides--may be taken up by tissue upon local application. Further research should study ex vivo local application of antisense ribozyme on human aortic wall, before assessing in vivo efficiency and tolerance of this aortic local vectorisation. It is always necessary to maintain a balanced magnesium intake in patients with MFS. Firstly to prevent the multiple noxious effects of magnesium deficiency on cardiovascular targets. Secondly to ensure the best efficiency and the least toxicity of the hemodynamic drugs used as long term prophylactic treatment for cardiovascular complications and of the etiologic antisense magnesium-dependent gene therapy, in the future.
Dohmen, Pascal M; Binner, Christian; Mende, Meinhart; Bakhtiary, Farhad; Etz, Christian; Pfannmüller, Bettina; Davierwala, Piroze; Borger, Michael A; Misfeld, Martin; Mohr, Friedrich W
2015-02-01
The high risk of morbidity and mortality for patients on hemodialysis who are undergoing cardiac surgery is increased for those with active infective endocarditis (AIE). This retrospective observational single-center study evaluated the impact of chronic hemodialysis on the outcome of aortic valve replacement in patients with aortic AIE. Data were retrospectively collected for consecutive patients undergoing aortic valve surgery for AIE diagnosed according to modified Duke criteria between October 1994 and January 2011. Characteristics and outcomes of patients receiving preoperative chronic hemodialysis were analyzed. Aortic valve AIE was present in 992 patients. Forty-five (4.5%) of the aortic valve AIE patients were receiving long-term hemodialysis preoperatively, 19 of whom (42.2%) had diabetes mellitus. Mean logistic EuroSCORE was 64.2% ± 32.2%. Twenty-four preoperative septic emboli were found in 15 patients. Results of microbiologic cultures were positive in 36 patients, with the major causative organisms identified as Staphylococcus aureus (n = 17) and Enterococcus faecalis (n = 10). Isolated aortic valve replacement was performed in 19 patients (42.2%), and 26 patients (57.8%) underwent concomitant procedures. The mean follow-up was 5.3 ± 5.2 years (range, 0.1 to 17.1 years). Postoperative complications occurred in 30 patients (66.7%). Nineteen patients (42.2%) died within 30 days of surgery, which in 8 patients was attributable to a cardiac cause. In patients receiving chronic hemodialysis who undergo aortic valve replacement for acute AIE, postoperative mortality is high, especially in patients undergoing aortic root replacement or culture-negative AIE. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.
Lu, Pong-Jeu; Yang, Chi-Fu Jeffrey; Wu, Meng-Yu; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng
2011-11-01
In counterpulsation, diastolic augmentation increases coronary blood flow and systolic unloading reduces left ventricular afterload. We present a new approach with wave intensity analysis to revisit and explain counterpulsation principles. In an acute porcine model, a standard intra-aortic balloon pump was placed in descending aorta in 4 pigs. We measured pressure and velocity with probes in left anterior descending artery and aorta during and without intra-aortic balloon pump assistance. Wave intensities of aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction. We identified predominating waves in counterpulsation. In the aorta, during diastolic augmentation, intra-aortic balloon inflation generated a backward compression wave, with a "pushing" effect toward the aortic root that translated to a forward compression wave into coronary circulation. During systolic unloading, intra-aortic balloon pump deflation generated a backward expansion wave that "sucked" blood from left coronary bed into the aorta. While this backward expansion wave translated to reduced left ventricular afterload, the "sucking" effect resulted in left coronary blood steal, as demonstrated by a forward expansion wave in left anterior descending coronary flow. The waves were sensitive to inflation and deflation timing, with just 25 ms delay from standard deflation timing leading to weaker forward expansion wave and less coronary regurgitation. Intra-aortic balloon pumps generate backward-traveling waves that predominantly drive aortic and coronary blood flow during counterpulsation. Wave intensity analysis of arterial circulations may provide a mechanism to explain diastolic augmentation and systolic unloading of intra-aortic balloon pump counterpulsation. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Bicuspid aortic valve hemodynamics: a fluid-structure interaction study
NASA Astrophysics Data System (ADS)
Chandra, Santanu; Seaman, Clara; Sucosky, Philippe
2011-11-01
The bicuspid aortic valve (BAV) is a congenital defect in which the aortic valve forms with two leaflets instead of three. While calcific aortic valve disease (CAVD) also develops in the normal tricuspid aortic valve (TAV), its progression in the BAV is more rapid. Although studies have suggested a mechano-potential root for the disease, the native BAV hemodynamics remains largely unknown. This study aimed at characterizing BAV hemodynamics and quantifying the degree of wall-shear stress (WSS) abnormality on BAV leaflets. Fluid-structure interaction models validated with particle-image velocimetry were designed to predict the flow and leaflet dynamics in idealized TAV and BAV anatomies. Valvular function was quantified in terms of the effective orifice area. The regional leaflet WSS was characterized in terms of oscillatory shear index, temporal shear magnitude and temporal shear gradient. The predictions indicate the intrinsic degree of stenosis of the BAV anatomy, reveal drastic differences in shear stress magnitude and pulsatility on BAV and TAV leaflets and confirm the side- and site-specificity of the leaflet WSS. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, these results support the existence of a mechano-etiology of CAVD in the BAV.
NASA Astrophysics Data System (ADS)
Hatoum, Hoda; Dasi, Lakshmi Prasad
2017-11-01
Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.
Girdauskas, Evaldas; Rouman, Mina; Borger, Michael A; Kuntze, Thomas
2013-12-01
The aim of this study was to evaluate aortic media changes in bicuspid aortic valve (BAV) patients who underwent aortic valve replacement (AVR) and simultaneous replacement of the proximal aorta for BAV stenosis vs BAV insufficiency. Review of our institutional BAV database identified a subgroup of 79 consecutive BAV patients (mean age 52.3 ± 13 years, 81% men) with BAV stenosis or insufficiency and concomitant proximal aortic dilatation of ≥50 mm who underwent AVR and simultaneous replacement of proximal aorta from 1995 through 2005. All cases of BAV disease and concomitant ascending aortic dilatation of 40-50 mm underwent isolated AVR and therefore were excluded from this analysis. Proximal aortic media elastic fibre loss (EFL) was assessed (graded 0 to 3+) and compared between patients with BAV stenosis (Group I, n = 44) vs BAV insufficiency (Group II, n = 35). Follow-up (690 patient-years) was 100% complete and 9.1 ± 4.6 years long. Mean aortic media EFL was 1.3 ± 0.7 in Group I vs 2.5 ± 0.8 in Group II (P = 0.03). Moderate/severe EFL (i.e. defined as grade 2+/3+) was found in 13 patients (29%) in Group I vs 28 patients (80%) in Group II (P < 0.001). Logistic regression identified BAV insufficiency as the strongest predictor of moderate/severe EFL (OR 9.3; 95% CI 3.2-29.8, P < 0.001). Valve-related event-free survival was 64 ± 8% in Group I vs 93% ± 5% in Group II at 10 years postoperatively (P = 0.05). A total of 4 patients (5%, 3 from Group I and 1 from Group II) underwent redo aortic root surgery for prosthetic valve endocarditis during follow-up. Patients with BAV insufficiency and a proximal aorta of ≥50 mm have a significantly higher rate of moderate/severe EFL as compared to their counterparts with BAV stenosis.
Thoracic aortic aneurysm clinically pertinent controversies and uncertainties.
Elefteriades, John A; Farkas, Emily A
2010-03-02
This paper addresses clinical controversies and uncertainties regarding thoracic aortic aneurysm and its treatment. 1) Estimating true aortic size is confounded by obliquity, asymmetry, and noncorresponding sites: both echocardiography and computed tomography/magnetic resonance imaging are necessary for complete assessment. 2) Epidemiology of thoracic aortic aneurysm. There has been a bona fide increase in incidence of aortic aneurysm making aneurysm disease the 18th most common cause of death. 3) Aortic growth rate. Although a virulent disease, thoracic aortic aneurysm is an indolent process. The thoracic aorta grows slowly-0.1 cm/year. 4) Evidence-based intervention criteria. It is imperative to extirpate the thoracic aorta before rupture or dissection occurs; surgery at 5.0- to 5.5-cm diameter will prevent most adverse natural events. Symptomatic (painful) aneurysms must be resected regardless of size. 5) Development of nonsize criteria. Mechanical properties of the aorta deteriorate at the same 6 cm at which dissection occurs; elastic properties of the aorta may soon become useful intervention criteria. 6) Medical treatment of aortic aneurysm. Medical treatment is of unproven value, even beta-blockers and angiotensin-receptor blockers. 7) A genetic disease. Even non-Marfan aneurysms have a strong genetic basis. 8) Need for biomarkers. Virulent but silent, TAA cries out for a biomarker that can predict the onset of adverse events. Pathophysiologic understanding has led to identification of promising biomarkers, especially metalloproteinases. 9) Endovascular therapy for aneurysms. Endovascular therapy has burgeoned, despite the fact that the EVAR-2, DREAM, and INSTEAD trials showed no benefit at mid-term over medical or conventional surgical therapy. We must avoid "irrational exuberance." 10) Inciting events for acute aortic dissection. Recent evidence shows that dissections are preceded by a specific severe exertional or emotional event. 11) "Silver lining" of aortic disease. Proximal aortic root disease seems to protect against arteriosclerosis. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Faure, Elsa Madeleine; El Batti, Salma; Abou Rjeili, Marwan; Ben Abdallah, Iannis; Julia, Pierre; Alsac, Jean-Marc
2018-05-17
The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Inadvertent transarterial insertion of atrial and ventricular defibrillator leads.
Issa, Ziad F; Rumman, Syeda S; Mullin, James C
2009-01-01
Inadvertent placement of pacemaker and implantable cardioverter-defibrillator (ICD) leads in the left ventricle (LV) is a rare but well-recognized complication of device implantation [1]. We report a case of inadvertent transarterial implantation of dual-chamber ICD leads; the ventricular lead positioned in the LV and the atrial lead positioned in the aortic root. The tip of the atrial lead migrated across the aortic wall and captured the epicardial surface of the left atrium. The diagnosis was made 5 years after the implantation procedure with no apparent adverse events directly related to left heart lead placement.
CT Findings of Ruptured Intramural Hematoma of the Aorta Extending Along the Pulmonary Artery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sueyoshi, Eijun, E-mail: EijunSueyoshi@aol.com; Sakamoto, Ichiro; Uetani, Masataka
Mediastinal hematoma extending along the pulmonary artery is a rare complication of Stanford type A classic (double-barreled) aortic dissection. Rupture from the posterior aspect of the aortic root penetrates the shared adventitia of the aorta and pulmonary artery. From this location, hematoma can spread along the adventitial planes of the pulmonary arteries out into the lungs. We report a case of ruptured intramural hematoma of the aorta (IMH) extending along the pulmonary artery. To our knowledge, this finding in patients with IMH has not been reported in the literature.
AP-1 Oligodeoxynucleotides Reduce Aortic Elastolysis in a Murine Model of Marfan Syndrome.
Arif, Rawa; Zaradzki, Marcin; Remes, Anca; Seppelt, Philipp; Kunze, Reiner; Schröder, Hannes; Schwill, Simon; Ensminger, Stephan M; Robinson, Peter N; Karck, Matthias; Müller, Oliver J; Hecker, Markus; Wagner, Andreas H; Kallenbach, Klaus
2017-12-15
Marfan syndrome is characterized by high expression of matrix metalloproteinases (MMPs) in aortic smooth muscle cells (AoSMCs) associated with medial elastolysis and aortic root aneurysm. We aimed to reduce aortic elastolysis through decrease of MMP expression with decoy oligodeoxynucleotides (dODNs) neutralizing the transcription factor activating factor-1 (AP-1). AP-1 abundance in nuclear extracts as well as MMP-2 and MMP-9 expression were significantly increased in isolated mAoSMC of mgR/mgR Marfan mice compared to wild-type cells. Exposure to AP-1 neutralizing dODNs resulted in a significant reduction of basal and interleukin-1β-stimulated MMP expression and activity in mAoSMCs. Moreover, increased migration and formation of superoxide radical anions was substantially decreased in mAoSMCs by AP-1 dODN treatment. Aortic grafts from donor Marfan mice were treated with AP-1- dODN ex vivo and implanted as infrarenal aortic interposition grafts in mgR/mgR mice. Pretreatment of aortic grafts with AP-1 dODN led to reduced elastolysis, macrophage infiltration, and MMP activity. Permeability of the endothelial monolayer was increased for dODN in mgR/mgR aortae with observed loss of tight junction proteins ZO-1 and occludin, enabling dODN to reach the tunica media. Targeting AP-1 activity offers a new potential strategy to treat the vascular phenotype associated with Marfan syndrome. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Source-case investigation of Mycobacterium wolinskyi cardiac surgical site infection.
Dupont, C; Terru, D; Aguilhon, S; Frapier, J-M; Paquis, M-P; Morquin, D; Lamy, B; Godreuil, S; Parer, S; Lotthé, A; Jumas-Bilak, E; Romano-Bertrand, S
2016-07-01
The non-tuberculous mycobacteria (NTM) Mycobacterium wolinskyi caused bacteraemia and massive colonization of an aortic prosthesis in a patient 16 days after cardiac surgery, necessitating repeat surgery and targeted antimicrobial chemotherapy. The infection control team investigated the source and conditions of infection. Peri-operative management of the patient complied with recommendations. The environmental investigation showed that although M. wolinskyi was not recovered, diverse NTM species were present in water from point-of-use taps and heater-cooler units for extracorporeal circulation. This case and increasing evidence of emerging NTM infections in cardiac surgery led to the implementation of infection control procedures in cardiac surgery wards. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality
Claiborne, Thomas E; Slepian, Marvin J; Hossainy, Syed; Bluestein, Danny
2013-01-01
Present prosthetic heart valves, while hemodynamically effective, remain limited by progressive structural deterioration of tissue valves or the burden of chronic anticoagulation for mechanical valves. An idealized valve prosthesis would eliminate these limitations. Polymeric heart valves (PHVs), fabricated from advanced polymeric materials, offer the potential of durability and hemocompatibility. Unfortunately, the clinical realization of PHVs to date has been hampered by findings of in vivo calcification, degradation and thrombosis. Here, the authors review the evolution of PHVs, evaluate the state of the art of this technology and propose a pathway towards clinical reality. In particular, the authors discuss the development of a novel aortic PHV that may be deployed via transcatheter implantation, as well as its optimization via device thrombogenicity emulation. PMID:23249154
Albes, Johannes M
2017-12-01
Interrupted pledget-armed braided sutures are widely used for valve implantation. In a 74-year-old woman with aortic valve endocarditis and shallow annular abscess, annulus dehiscence resulted after resection. As resistance was too high for sufficient primary approximation, a snug fit of the valve by means of circumferential application of curbed tourniquets resembling Medusa's head after suture placement was achieved. Closest possible approximation of the upper and lower part of the annulus with the prosthesis prior to final fixation was thus possible, so that application of too much tension on a single suture could be avoided. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Aortic microcalcification is associated with elastin fragmentation in Marfan syndrome.
Wanga, Shaynah; Hibender, Stijntje; Ridwan, Yanto; van Roomen, Cindy; Vos, Mariska; van der Made, Ingeborg; van Vliet, Nicole; Franken, Romy; van Riel, Luigi Amjg; Groenink, Maarten; Zwinderman, Aeilko H; Mulder, Barbara Jm; de Vries, Carlie Jm; Essers, Jeroen; de Waard, Vivian
2017-11-01
Marfan syndrome (MFS) is a connective tissue disorder in which aortic rupture is the major cause of death. MFS patients with an aortic diameter below the advised limit for prophylactic surgery (<5 cm) may unexpectedly experience an aortic dissection or rupture, despite yearly monitoring. Hence, there is a clear need for improved prognostic markers to predict such aortic events. We hypothesize that elastin fragments play a causal role in aortic calcification in MFS, and that microcalcification serves as a marker for aortic disease severity. To address this hypothesis, we analysed MFS patient and mouse aortas. MFS patient aortic tissue showed enhanced microcalcification in areas with extensive elastic lamina fragmentation in the media. A causal relationship between medial injury and microcalcification was revealed by studies in vascular smooth muscle cells (SMCs); elastin peptides were shown to increase the activity of the calcification marker alkaline phosphatase (ALP) and reduce the expression of the calcification inhibitor matrix GLA protein in human SMCs. In murine Fbn1 C1039G/+ MFS aortic SMCs, Alpl mRNA and activity were upregulated as compared with wild-type SMCs. The elastin peptide-induced ALP activity was prevented by incubation with lactose or a neuraminidase inhibitor, which inhibit the elastin receptor complex, and a mitogen-activated protein kinase kinase-1/2 inhibitor, indicating downstream involvement of extracellular signal-regulated kinase-1/2 (ERK1/2) phosphorylation. Histological analyses in MFS mice revealed macrocalcification in the aortic root, whereas the ascending aorta contained microcalcification, as identified with the near-infrared fluorescent bisphosphonate probe OsteoSense-800. Significantly, microcalcification correlated strongly with aortic diameter, distensibility, elastin breaks, and phosphorylated ERK1/2. In conclusion, microcalcification co-localizes with aortic elastin degradation in MFS aortas of humans and mice, where elastin-derived peptides induce a calcification process in SMCs via the elastin receptor complex and ERK1/2 activation. We propose microcalcification as a novel imaging marker to monitor local elastin degradation and thus predict aortic events in MFS patients. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.
Armstrong, Anderson C.; Ricketts, Erin P.; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; RDCS; Sidney, Stephen; Lewis, Cora E.; Schreiner, Pamela J.; Shikany, James M.; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S.; Lima, João A. C.
2014-01-01
Introduction Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultra-sound, particularly in novel techniques such as Speckle Tracking (STE). We evaluate the echocardiography assessment performance in the CARDIA study Y25 examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and Reading Center (RC) accuracy. Methods The CARDIA Y25 examination had 3,475 echocardiograms performed in 4 US Field Centers and analyzed in a Reading Center, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (2- and 4-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intra-class correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. Results For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and 4-chamber and 58% in 2-chamber. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with Echo RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Conclusion Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. PMID:25382818
Armstrong, Anderson C; Ricketts, Erin P; Cox, Christopher; Adler, Paul; Arynchyn, Alexander; Liu, Kiang; Stengel, Ellen; Sidney, Stephen; Lewis, Cora E; Schreiner, Pamela J; Shikany, James M; Keck, Kimberly; Merlo, Jamie; Gidding, Samuel S; Lima, João A C
2015-08-01
Few large studies describe quality control procedures and reproducibility findings in cardiovascular ultrasound, particularly in novel techniques such as speckle tracking echocardiography (STE). We evaluate the echocardiography assessment performance in the Coronary Artery Risk Development in Young Adults (CARDIA) study Year 25 (Y25) examination (2010-2011) and report findings from a quality control and reproducibility program conducted to assess Field Center image acquisition and reading center (RC) accuracy. The CARDIA Y25 examination had 3475 echocardiograms performed in 4 US Field Centers and analyzed in a RC, assessing standard echocardiography (LA dimension, aortic root, LV mass, LV end-diastolic volume [LVEDV], ejection fraction [LVEF]), and STE (two- and four-chamber longitudinal, circumferential, and radial strains). Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman plots. For standard echocardiography reproducibility, LV mass and LVEDV consistently had CV above 10% and aortic root below 6%. Intra-sonographer aortic root and LV mass had the most robust values of ICC in standard echocardiography. For STE, the number of properly tracking segments was above 80% in short-axis and four-chamber and 58% in two-chamber views. Longitudinal strain parameters were the most robust and radial strain showed the highest variation. Comparing Field Centers with echocardiography RC STE readings, mean differences ranged from 0.4% to 4.1% and ICC from 0.37 to 0.66, with robust results for longitudinal strains. Echocardiography image acquisition and reading processes in the CARDIA study were highly reproducible, including robust results for STE analysis. Consistent quality control may increase the reliability of echocardiography measurements in large cohort studies. © 2014, Wiley Periodicals, Inc.
Kostogrys, Renata B; Franczyk-Zarow, Magdalena; Gasior-Glogowska, Marlena; Kus, Edyta; Jasztal, Agnieszka; Wrobel, Tomasz P; Baranska, Malgorzata; Czyzynska-Cichon, Izabela; Drahun, Anna; Manterys, Angelika; Chlopicki, Stefan
2017-02-01
Cholesterol-dependent and independent mechanisms were proposed to explain anti-atherosclerotic action of statins in humans. However, their effects in murine models of atherosclerosis have not been consistently demonstrated. Here, we studied the effects of pravastatin on atherosclerosis in ApoE/LDLR -/- mice fed a control and atherogenic diet. ApoE/LDLR -/- mice were fed a control (CHOW) or an atherogenic (Low Carbohydrate High Protein, LCHP) diet. Two doses of pravastatin (40mg/kg and 100mg/kg) were used. The anti-atherosclerotic effects of pravastatin in en face aorta, cross-sections of aortic roots and brachiocephalic artery (BCA) were analysed. The lipid profile was determined. Fourier Transform Infrared Spectroscopy followed by Fuzzy C-Means (FCM) clustering was used for the quantitative assessment of plaque composition. Treatment with pravastatin (100mg/kg) decreased total and LDL cholesterol only in the LCHP group, but displayed a pronounced anti-atherosclerotic effect in BCA and abdominal aorta. The anti-atherosclerotic effect of pravastatin (100mg/kg) in BCA was associated with significant alterations of the chemical plaque composition, including a fall in cholesterol and cholesterol esters contents independently on total cholesterol and LDL concentration in plasma. Pravastatin at high (100mg/kg), but not low dose displayed a pronounced anti-atherosclerotic effect in ApoE/LDLR -/- mice fed a CHOW or LCHP diet that was remarkable in BCA, visible in en face aorta, whereas it was not observed in aortic roots, suggesting that previous inconsistencies might have been due to the various sites of atherosclerotic plaque analysis. Copyright © 2016. Published by Elsevier Urban & Partner Sp. z o.o.
Sievers, Hans-Hinrich; Scharfschwerdt, Michael; Putman, Léon M
2015-08-01
The currently most frequently used technique for the arterial switch operation (ASO) in simple transposition of the great arteries (TGA) includes the transposition of the pulmonary artery anterior to the ascending aorta. This arterial arrangement is less anatomical, and although the initial results are excellent, some long-term data are indicating a certain risk of morbidity, encouraging the search for more physiological techniques. As a first step, we studied the feasibility of anatomical spiral anastomoses of the great vessels in vitro. A TGA model was constructed to simulate the different spatial positions of the great arteries followed by ASO with physiological spiral connections of the great arteries. It was possible to perform a physiological spiral connection of the great arteries without tension or torsion when the roots of the great vessels were arranged anterior-posterior and with up to 35° rotation of the aortic root to the right around the pulmonary root. With further rotation of the aorta, patch plasties were required for pulmonary artery elongation. The maximal width of the patch was 5 mm. In this TGA model, it was possible to perform tension- and torsion-free arterial anastomoses for ASO without artificial material, when the aortic root was positioned from 0° up to 35° to the right of the pulmonary root. Evaluation of coronary transfer is the next step. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Ramos, Antonio; García-Montero, Carlos; Moreno, Alfonso; Muñoz, Patricia; Ruiz-Morales, Josefa; Sánchez-Espín, Gemma; Porras, Carlos; Sousa, Dolores; Castelo, Laura; Del Carmen Fariñas, María; Gutiérrez, Francisco; Reguera, José María; Plata, Antonio; Bouza, Emilio; Antorrena, Isabel; de Alarcón, Arístides; Pericás, José Manuel; Gurguí, Mercedes; Rodríguez-Abella, Hugo; Ángel Goenaga, Miguel; Antonio Oteo, José; García-Pavía, Pablo
2016-12-01
Endocarditis in patients with ascending aortic prosthetic graft (AAPG) is a life-threatening complication. The purpose of this study was to examine the clinical presentation and prognosis of patients with AAPG endocarditis included in a large prospective infectious endocarditis multicentre study. From January 2008 to April 2015, 3200 consecutive patients with infectious endocarditis according to the modified Duke criteria, were prospectively included in the 'Spanish Collaboration on Endocarditis Registry (GAMES)' registry. Twenty-seven definite episodes of endocarditis (0.8%) occurred in patients with AAPG. During the study period, 27 cases of endocarditis were detected in patients with AAPG. The median age of patients was 61 years [interquartile range (IQR) 51-68 years] and 23 (85.2%) patients were male. The median time from AAPG surgery to the episode of AAPG infection was 24 months (IQR 6-108 months). The most frequently isolated micro-organisms were coagulase-negative staphylococci and S. aureus (11 patients, 40.7%). Four patients (14.8%) underwent medical treatment, whereas surgery was performed in 21 (77.7%). Two patients (7.4%) died before surgery could be performed. The median hospital stay prior to surgery was 7 days (IQR 4-21 days). Surgery consisted of replacing previous grafts with a composite aortic graft (10 cases) or aortic homograft (2 patients), and removal of a large vegetation attached to the valve of a composite tube (1 case). Nine patients had an infected aortic valve prosthesis without evidence of involvement of the AAPG. Isolated redo-aortic valve replacement was performed in 8 (88.9%) of these patients. Reinfection occurring during 1 year of follow-up was not detected in any patient. Two patients (7.4%) died while awaiting surgery and 6 did so after surgery (22.2%). A New York Heart Association (NYHA) Class IV was associated with mortality in patients undergoing surgery (P < 0.019). Most cases of endocarditis in patients with AAPG occur late after initial surgery. Mortality rate of patients with AAPG endocarditis who undergo surgery is acceptable. NYHA Class IV before surgery is associated with an increased postoperative mortality. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Kilic, Salih; Saracoglu, Erhan; Cekici, Yusuf
2018-03-01
The objective of this study was to investigate the prevalence of abdominal aortic aneurysm (AAA) in Turkish patients aged ≥ 65 years, and to demonstrate the applicability of echocardiography to AAA screening. Transthoracic echocardiography (TTE) was performed in all consecutive patients aged ≥ 65 years who were referred to cardiology clinics or were referred from other outpatient clinics. The abdominal aorta (AA) of each patient was scanned using the same probe, and the time spent was recorded. Demographic and clinic characteristics of the patients were recorded at the end of the echocardiography. Among 1948 patients (mean age 70.9 ± 6 years; 49.8% male), the AA was visualized in 96.3%. AAA was identified in 3.7% (69/1878) of the patients, of whom AAA was previously known in 20.3% (n = 14). The prevalence of unknown AAA was 2.93%. The average time needed to scan and measure the AA was 1 minute and 3 seconds (±23 seconds). Aortic root diameters were significantly higher in the patients with AAA than in those without AAA (34.7 ± 4.2 vs. 29.8 ± 4.7; p < 0.001). Age (per 1 year increase) [odds ratio (OR), 1.245; p < 0.001], male gender (OR, 5.382; p < 0.001), smoking (OR, 2.118; p = 0.037), and aortic root diameter (per 1 mm increase) (OR, 1.299; p < 0.001) were independent predictors of AAA. This study is important in that it showed a high prevalence of AAA in Turkish patients aged ≥ 65 years, and demonstrated that AAA can be visualized in the majority of patients in as little as 1 minute during TTE.
McElhinney, Doff B; Lacro, Ronald V; Gauvreau, Kimberlee; O'Brien, Cheryl M; Yaroglu Kazanci, Selcen; Vogel, Melanie; Emani, Sitaram; Brown, David W
2012-09-01
Dilation of the ascending aorta (AA) is common in patients with a bicuspid aortic valve. The natural history of the aortic root and AA and the risk factors for dilation have not been characterized in patients with congenital aortic stenosis (AS) treated with balloon valvuloplasty during childhood. The present study was performed to determine the prevalence of aortic dilation in patients with congenital AS before and up to 20 years after balloon valvuloplasty performed during childhood. In patients who underwent balloon valvuloplasty for AS at age ≤ 18 years from 1984 to 2005, the aortic diameter measurements before intervention and at 5-year intervals afterward were recorded and the Z scores calculated. Among 156 patients (median age 1.5 years at valvuloplasty), the AA Z scores were significantly larger than normal before intervention (median Z score 1.5) and at all follow-up points (all p <0.001). Using mixed modeling, with time as a categorical variable (before intervention, 5-year window, 10-year window, and so forth), the mean AA Z score was greater at all postvalvuloplasty points than before the intervention, with mean Z score increases of 1.20 at 5 years and 2.11 at 20 years (p <0.001). Moderate or greater aortic regurgitation early after valvuloplasty was associated with greater AA Z scores than mild or less aortic regurgitation, with a progressive difference over time. More significant residual AS after valvuloplasty was associated with lower AA Z scores over time. In conclusion, AA dilation is common in children with congenital AS and continues to progress over many years after balloon valvuloplasty. Copyright © 2012 Elsevier Inc. All rights reserved.
Vocal cord paralysis after aortic surgery.
DiLisio, Ralph P; Mazzeffi, Michael A; Bodian, Carol A; Fischer, Gregory W
2013-06-01
The purpose of this study was to investigate variables associated with vocal cord paralysis during complex aortic procedures. A retrospective review. A tertiary care center. Four hundred ninety-eight patients who underwent aortic surgery between 2002 and 2007. Two groups were studied. Group A patients had procedures only involving their aortic root and/or ascending aorta. Group B patients had procedures only involving their aortic arch and/or descending aorta. The incidence of vocal cord paralysis was higher (7.26% v 0.8%) in group B patients (p < 0.0001). Increasing the duration of cardiopulmonary bypass time was associated with an increased risk of vocal cord paralysis and death in both groups A and B (p = 0.0002 and 0.002, respectively). Additionally, within group B, descending aneurysms emerged as an independent risk factor associated with vocal cord paralysis (p = 0.03). Length of stay was statistically significantly longer among group A patients who suffered vocal cord paralysis (p = 0.017) and trended toward significance in group B patients who suffered vocal cord paralysis (p = 0.059). The association between tracheostomy and vocal cord paralysis among group A patients reached statistical significance (p = 0.007) and trended toward significance in group B patients (p = 0.057). Increasing duration of cardiopulmonary bypass time was associated with a higher risk of vocal cord paralysis in patients undergoing aortic surgery. Additionally, within group B patients, descending aortic aneurysm was an independent risk factor associated with vocal cord paralysis. Most importantly, vocal cord paralysis appeared to have an association between an increased length of stay and tracheostomy among a select group of patients undergoing aortic surgery. Copyright © 2013 Elsevier Inc. All rights reserved.
Possible extracardiac predictors of aortic dissection in Marfan syndrome
2014-01-01
Background According to previous studies, aortic diameter alone seems to be insufficient to predict the event of aortic dissection in Marfan syndrome (MFS). Determining the optimal schedule for preventive aortic root replacement (ARR) aortic growth rate is of importance, as well as family history, however, none of them appear to be decisive. Thus, the aim of this study was to search for potential predictors of aortic dissection in MFS. Methods A Marfan Biobank consisting of 79 MFS patients was established. Thirty-nine MFS patients who underwent ARR were assigned into three groups based on the indication for surgery (dissection, annuloaortic ectasia and prophylactic surgery). The prophylactic surgery group was excluded from the study. Transforming growth factor-β (TGF-β) serum levels were measured by ELISA, relative expression of c-Fos, matrix metalloproteinase 3 and 9 (MMP-3 and −9) were assessed by RT-PCR. Clinical parameters, including anthropometric variables - based on the original Ghent criteria were also analyzed. Results Among patients with aortic dissection, TGF-β serum level was elevated (43.78 ± 6.51 vs. 31.64 ± 4.99 ng/l, p < 0.0001), MMP-3 was up-regulated (Ln2α = 1.87, p = 0.062) and striae atrophicae were more common (92% vs. 41% p = 0.027) compared to the annuloaortic ectasia group. Conclusions We found three easily measurable parameters (striae atrophicae, TGF-β serum level, MMP-3) that may help to predict the risk of aortic dissection in MFS. Based on these findings a new classification of MFS, that is benign or malignant is also proposed, which could be taken into consideration in determining the timing of prophylactic ARR. PMID:24720641
Contemporary insights into the management of type A aortic dissection.
Tolis, George; Sundt, Thoralf M
2016-10-01
Acute Type A Dissection remains a surgical emergency with a relatively high operative mortality despite advances in cardiac surgical techniques and medical management over the past thirty years. In this presentation we will discuss the issues surrounding diagnosis, triage, surgical treatment and perioperative medical management as well as long term surveillance of patients suffering from Acute Type A Dissection and present the literature that supports our management strategies. Expert commentary: The ultimate goal of surgical intervention for patients with Type A Acute Aortic Dissection is an alive patient. A more complicated operation which addresses the root and arch and potentially reduces late complications should be approached with caution since it may increase the operative mortality of the procedure itself. With the recent evolution in endovascular techniques, there is hope that later complications can be reduced without increasing the risk of the primary operation. It remains to be seen whether the improved distal aortic remodeling afforded by a combined open/endovascular approach to Acute Type A Dissection will lead to decreased need for aortic reinterventions and overall long term complications of a residual descending thoracic chronic dissection.
Watanabe, Yoshinori
2015-01-01
Prosthetic vascular graft infection in the thoracic aortic area is a rare but serious complication. Adequate management of the complication is essential to increase the chance of success of open surgery. While surgical site infection is suggested as the root cause of the complication, it is also related to decreased host tolerance, especially as found in elderly patients. The handling of prosthetic vascular graft infection has been widely discussed to date. This paper mainly provides a summary of literature reports published within the past 5 years to discuss issues related to multidisciplinary treatment approaches, including surgical site infection, timing of onset, diagnostic methods, causative pathogens, auxiliary diagnostic methods, antibiotic treatment, anti-infective structures of vascular prostheses, surgical treatment, treatment strategy against infectious aortic aneurysms, future surgical treatment, postoperative systemic therapy, and antimicrobial stewardship. A thorough understanding of these issues will enable us to prevent prosthetic vascular graft infection in the thoracic aortic area as far as possible. In the event of its occurrence, the early introduction of appropriate treatment is expected to cure the disease without worsening of the underlying pathological condition. PMID:26356686
Dietel, Barbara; Muench, Rabea; Kuehn, Constanze; Kerek, Franz; Steinkasserer, Alexander; Achenbach, Stephan; Garlichs, Christoph D; Zinser, Elisabeth
2014-08-01
Inflammation accelerates both plaque progression and instability in the pathogenesis of atherosclerosis. The inhibition of dendritic cell (DC) maturation is a promising approach to suppress excessive inflammatory immune responses and has been shown to be protective in several autoimmune models. The aim of this study was to investigate the immune modulatory effects of the natural substance MCS-18, an inhibitor of DC maturation, regarding the progression of atherosclerosis in ApoE-deficient mice. ApoE-deficient mice were fed for twelve weeks with a Western-type diet (n = 32) or normal chow (control group; n = 16). Animals receiving high-fat diet were treated with MCS-18 (500 μg/kg body weight, n = 16) or saline (n = 16) twice a week. After 12 weeks, animals were transcardially perfused and sacrificed. The percentage of mature DCs (CD3(-)/CD19(-)/CD14(-)/NK1.1(-)/CD11c(+)/MHCII(+)/CD83(+)/CD86(+)) and T cell subpopulations (CD4(+)/CD25(+)/Foxp3(+), CD3/CD4/CD8) was analyzed in peripheral blood and in the spleen using flow cytometry. Plaque size was determined in the aortic root and the thoracoabdominal aorta using en-face staining. Immunohistochemical stainings served to detect inflammatory cells in the aortic root. Several cytokines and chemokines were determined in serum using multiplex assays. In splenic cells derived from saline-treated atherosclerotic mice an increased DC maturation, reflected by the upregulation of CD83 and CD86 expression, was observed. The enhanced expression of both maturation markers was absent in MCS-18 treated atherosclerotic mice. While the percentage of splenic Foxp3 expressing Treg was increased in animals receiving MCS-18 compared to saline-treated atherosclerotic mice, cytotoxic T cells were reduced in the spleen and in atherosclerotic lesions of the aortic root. Furthermore, proatherogenic cytokines (e.g. IL-6 and IFN-γ) and chemokines (e.g. MIP-1β) were decreased in serum of MCS-18-treated animals when compared to saline-treated atherosclerotic mice. Also plaque size in the aortic root and the thoracoabdominal aorta was significantly lower following administration of MCS-18. This study provides for the first time evidence that MCS-18 is able to prevent the onset of atherosclerosis in ApoE-deficient mice. The observed anti-atherogenic effect is associated with the suppression of DC maturation and an inhibited migration and proliferation of cytotoxic T cells. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Physiological rules for the heart, lungs and other pressure-based organs
Camilleri, Liberato; Manché, Alexander; Gatt, Ruben; Gauci, Marilyn; Camilleri-Podesta, Marie-Therese; Grima, Joseph N.; Chetcuti, Stanley
2017-01-01
Background The adherence of the heart to physical laws, such as Laplace’s Law, may act as a measure of the organ’s relative efficiency. Allometric relationships were investigated to assess the heart’s efficiency concerning end-diastolic and end-systolic volumes, cardiac pressurization energy, cardiac output and mass. Methods Data to generate allometric relationships was obtained using a literature search, identifying heart and lung data across different mammalian and bird species. Statistical analysis was carried out using ordinary least squares (OLS) estimation. Results Near isometric relationships exist between body mass and seven parameters indicating no “efficiency of size” with scaling of the heart, and size-matching of the heart to the lungs and whole body. Even though there was equal efficiency in pressurization energy generation, cardiac output was maximally efficient in small mammals <10 kg and birds; the human heart reached only 71% efficiency. This loss in cardiac efficiency with increasing body mass can be explained by the aortic cross-section that scales following the three-quarter allometry law, compared to end-systolic and end-diastolic volumes that scale isometrically. The heart is therefore throttled by a relatively small aorta at large body size. Conclusions Mammalian and avian hearts operate at similar efficiencies, demonstrating a high degree of symmorphosis, however cardiac output efficiency decreases in larger animals due to a relatively negative aortic cross-section allometry. This work has a myriad of potential applications including explaining cardiac dysfunction in athletes, patient-prosthesis mismatch in aortic valve replacement and why heavy exercise is associated with a worse prognosis than mild or moderate exercise. PMID:29268387
Santoro, Rosaria; Consolo, Filippo; Spiccia, Marco; Piola, Marco; Kassem, Samer; Prandi, Francesca; Vinci, Maria Cristina; Forti, Elisa; Polvani, Gianluca; Fiore, Gianfranco Beniamino; Soncini, Monica; Pesce, Maurizio
2016-02-01
Glutaraldehyde-fixed pericardium of animal origin is the elective material for the fabrication of bio-prosthetic valves for surgical replacement of insufficient/stenotic cardiac valves. However, the pericardial tissue employed to this aim undergoes severe calcification due to chronic inflammation resulting from a non-complete immunological compatibility of the animal-derived pericardial tissue resulting from failure to remove animal-derived xeno-antigens. In the mid/long-term, this leads to structural deterioration, mechanical failure, and prosthesis leaflets rupture, with consequent need for re-intervention. In the search for novel procedures to maximize biological compatibility of the pericardial tissue into immunocompetent background, we have recently devised a procedure to decellularize the human pericardium as an alternative to fixation with aldehydes. In the present contribution, we used this procedure to derive sheets of decellularized pig pericardium. The decellularized tissue was first tested for the presence of 1,3 α-galactose (αGal), one of the main xenoantigens involved in prosthetic valve rejection, as well as for mechanical tensile behavior and distensibility, and finally seeded with pig- and human-derived aortic valve interstitial cells. We demonstrate that the decellularization procedure removed the αGAL antigen, maintained the mechanical characteristics of the native pig pericardium, and ensured an efficient surface colonization of the tissue by animal- and human-derived aortic valve interstitial cells. This establishes, for the first time, the feasibility of fixative-free pericardial tissue seeding with valve competent cells for derivation of tissue engineered heart valve leaflets. © 2015 Wiley Periodicals, Inc.
Finotello, Alice; Morganti, Simone; Auricchio, Ferdinando
2017-09-01
In the last few years, several studies, each with different aim and modeling detail, have been proposed to investigate transcatheter aortic valve implantation (TAVI) with finite elements. The present work focuses on the patient-specific finite element modeling of the aortic valve complex. In particular, we aim at investigating how different modeling strategies in terms of material models/properties and discretization procedures can impact analysis results. Four different choices both for the mesh size (from 20 k elements to 200 k elements) and for the material model (from rigid to hyperelastic anisotropic) are considered. Different approaches for modeling calcifications are also taken into account. Post-operative CT data of the real implant are used as reference solution with the aim of outlining a trade-off between computational model complexity and reliability of the results. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Cardiovascular and Musculoskeletal Assessment of Elite US Volleyball Players.
Davis, Christopher K; Dyar, Dan A; Vargas, Lisa A; Grossfeld, Paul D
2015-11-01
The aim of this study was to characterize the cardiovascular and musculoskeletal systems of elite volleyball players, including aortic dimensions. Previous studies have shown that the upper limit of normal aortic sinus diameter for male and female athletes is 4 and 3.4 cm, respectively. Cross-sectional analysis. United States Olympic Volleyball Training Facility and Rady Children's Hospital San Diego. Seventy (37 male) members of the US national volleyball team. Athletes underwent evaluation that included medical and family histories, targeted physical examinations specifically focusing on abnormalities present in Marfan syndrome (MFS), and transthoracic echocardiograms. Cardiac chamber and great artery size, valve function, and coronary artery origins were assessed. Three male athletes (8%) had an aortic sinus diameter ≥4 cm, one of whom also had an ascending aorta >4 cm. Two female athletes (6%) had aortic sinus diameter ≥3.4 cm, and another had an ascending aorta of 3.4 cm. There were no other intracardiac or arterial abnormalities. Individual musculoskeletal characteristics of MFS were common among the athletes but not more frequent or numerous in those with aortic dilation. The prevalence of aortic root dilation in this population of athletes was higher than what has previously been reported in other similar populations. Further study is needed to determine whether these represent pathological changes or normal variations in tall athletes. This study adds to the existing knowledge base of athlete's heart, with specific attention to aortic dimensions in elite volleyball players. The data are relevant to similar athletes' medical care and to preparticipation cardiac screening in general.
Aortic dissection in patients with Marfan syndrome based on the IRAD data
de Beaufort, Hector W. L.; Korach, Amit; Di Eusanio, Marco; Gilon, Dan; Montgomery, Daniel G.; Evangelista, Arturo; Braverman, Alan C.; Chen, Edward P.; Isselbacher, Eric M.; Gleason, Thomas G.; De Vincentiis, Carlo; Sundt, Thoralf M.; Patel, Himanshu J.; Eagle, Kim A.
2017-01-01
Between January 1996 and May 2017, the International Registry on Acute Aortic Dissections has collected information on a total of 6,424 consecutive patients with acute aortic dissection, including 258 individuals with a diagnosis of Marfan syndrome. Patients with Marfan syndrome presented at a significantly younger age compared to patients without Marfan syndrome (38.2±13.2 vs. 63.0±14.0 years; P<0.001) and in general had fewer comorbidities, although they more frequently had a known aortic aneurysm and history of prior cardiac surgery. We noted significantly larger diameters of the aortic annulus and root in the Marfan syndrome cohort, but no larger diameters more distally. The in-hospital mortality in type A dissection was not significantly different in patients with or without Marfan syndrome, despite the differences in age and comorbidities and the lower incidence of aortic rupture in the Marfan syndrome cohort. In contrast, the in-hospital mortality of Marfan syndrome patients with type B dissection appears to be lower than that of patients without Marfan syndrome. The Marfan syndrome cohort that was treated with open surgery for type B dissection seemed to do especially well, with a 0% mortality rate (n=27). Follow-up data for type A and B dissections combined show an estimated five-year survival rate of 80.1% and an estimated reintervention rate of 55.3% in patients with Marfan syndrome. Such a high rate of reinterventions highlights the need for careful surveillance and treatment for patients with Marfan syndrome surviving the acute phase of aortic dissection. PMID:29270375
Aortic dissection in patients with Marfan syndrome based on the IRAD data.
de Beaufort, Hector W L; Trimarchi, Santi; Korach, Amit; Di Eusanio, Marco; Gilon, Dan; Montgomery, Daniel G; Evangelista, Arturo; Braverman, Alan C; Chen, Edward P; Isselbacher, Eric M; Gleason, Thomas G; De Vincentiis, Carlo; Sundt, Thoralf M; Patel, Himanshu J; Eagle, Kim A
2017-11-01
Between January 1996 and May 2017, the International Registry on Acute Aortic Dissections has collected information on a total of 6,424 consecutive patients with acute aortic dissection, including 258 individuals with a diagnosis of Marfan syndrome. Patients with Marfan syndrome presented at a significantly younger age compared to patients without Marfan syndrome (38.2±13.2 vs . 63.0±14.0 years; P<0.001) and in general had fewer comorbidities, although they more frequently had a known aortic aneurysm and history of prior cardiac surgery. We noted significantly larger diameters of the aortic annulus and root in the Marfan syndrome cohort, but no larger diameters more distally. The in-hospital mortality in type A dissection was not significantly different in patients with or without Marfan syndrome, despite the differences in age and comorbidities and the lower incidence of aortic rupture in the Marfan syndrome cohort. In contrast, the in-hospital mortality of Marfan syndrome patients with type B dissection appears to be lower than that of patients without Marfan syndrome. The Marfan syndrome cohort that was treated with open surgery for type B dissection seemed to do especially well, with a 0% mortality rate (n=27). Follow-up data for type A and B dissections combined show an estimated five-year survival rate of 80.1% and an estimated reintervention rate of 55.3% in patients with Marfan syndrome. Such a high rate of reinterventions highlights the need for careful surveillance and treatment for patients with Marfan syndrome surviving the acute phase of aortic dissection.
Dong, Pei-qing; Guan, Yu-long; He, Mei-ling; Yang, Jing; Wan, Cai-hong; Du, Shun-ping
2003-02-01
To assess retrospectively the effects of different protective methods on brain in ascending aortic aneurysm surgery. In 65 patients, aneurysm was dissected to the aortic arch or right arch. To protect brain, deep hypothermic circulatory arrest (DHCA) combined with retrograde cerebral perfusion (RCP) through the superior vena cava (n = 50) and simple DHCA (n = 15) were used during the procedure. Blood samples for lactic acid level from the jugular vein were compared in both groups at different phase, and perfusion blood distribution and oxygen content difference between the perfused and returned blood were measured in some RCP patients. The DHCA time was 35.9 +/- 18.8 min (10.0 - 63.0 min) and DHCA + RCP time was 45.5 +/- 17.2 min (16.0 - 81.0 min). The resuscitation time was 7.1 +/- 1.6 h (4.4 - 9.4 h) in DHCA patients and 5.4 +/- 2.2 h (2.0 - 9.0 h) in RCP patients. Operation death was 3/15 in the DHCA group and 1/50 in the RCP patients. Central nervous complication existed in 3/12 of DHCA patients and 1/49 of RCP patients (P < 0.01). The overall survival rate was 96% (RCP) vs 67% (DHCA), central nervous system dysfunction was 20% in DHCA vs 2% in RCP (P < 0.01). The blood lactic acid level increased significantly after reperfusion in DHCA than in RCP. The blood distribution measurement approximated to 20% of the perfused blood returned from arch vessels. Oxygen content between perfused and returned blood showed that oxygen uptake was adequate in the RCP group. The application of RCP could prolong the safety duration of circulation arrest. Cerebral perfusion may reep the brain cool and flush out particulate and air embolism. Open anastomosis of the aortic arch to the prosthesis can be safely performed. RCP is acceptable for brain protection in clinical practice.
Reuthebuch, Oliver; Inderbitzin, Devdas Thomas; Rüter, Florian; Jeger, Raban; Kaiser, Christoph; Buser, Peter; Fassl, Jens; Eckstein, Friedrich S
2014-01-01
We present the post-CE(Conformité Européenne)-mark single-center implantation experience and short-term outcome with the second-generation transapical JenaValve transcatheter aortic valve implantation system. Patients [N = 27; 9 women; mean (SD) age, 80.3 (5.5) years] were operated on between November 2011 and August 2012. Via a transapical approach, the valve was positioned, in some cases, repositioned, and finally implanted. All data were collected during the hospital stay. The implantation success rate was 100%; the mean (SD) operation time was 124.7 (43.2) minutes; and the size of the implanted prosthesis was 23 mm (n = 6), 25 mm (n = 14), and 27 mm (n = 7). The in-hospital major adverse cardiac and cerebrovascular events were as follows: intraoperative resuscitation with subsequent aortic rupture (n = 1), postoperative hemorrhage needing revision (n = 1), myocardial infarction (n = 1), atrioventricular block needing a definitive pacemaker (n = 1), new-onset renal failure needing hemodialysis (n = 1), and stroke (n = 1). The 30-day mortality was 11.1% (n = 3). The mean (SD) intensive care unit/total stay was 2.2 (1.7)/11.7 (7.9) days. Postoperative echocardiography [day 6.7 (4.8)] revealed residual paravalvular leakage of trace to grade 1 in 12 patients (44.5%) and no leakage in 15 patients, with a mean (SD) transvalvular pressure gradient of 11.6 (5.6) mm Hg with significant reduction by 36.0 (17.7) mm Hg (P = 0.0001, Wilcoxon signed rank test). This second-generation repositionable transcatheter aortic valve implantation device could safely and successfully be implanted with a fast learning curve, significant reduction in pressure gradients, overall clinical improvement at discharge, as well as an acceptable morbidity and mortality rate in this highest-risk patient cohort.
Incidence, predictors and clinical outcomes of residual stenosis after aortic valve-in-valve.
Bleiziffer, Sabine; Erlebach, Magdalena; Simonato, Matheus; Pibarot, Philippe; Webb, John; Capek, Lukas; Windecker, Stephan; George, Isaac; Sinning, Jan-Malte; Horlick, Eric; Napodano, Massimo; Holzhey, David M; Petursson, Petur; Cerillo, Alfredo; Bonaros, Nikolaos; Ferrari, Enrico; Cohen, Mauricio G; Baquero, Giselle; Jones, Tara L; Kalra, Ankur; Reardon, Michael J; Chhatriwalla, Adnan; Gama Ribeiro, Vasco; Alnasser, Sami; Van Mieghem, Nicolas M; Rustenbach, Christian Jörg; Schofer, Joachim; Garcia, Santiago; Zeus, Tobias; Champagnac, Didier; Bekeredjian, Raffi; Kornowski, Ran; Lange, Rüdiger; Dvir, Danny
2018-05-01
We aimed to analyse the incidence of prosthesis-patient mismatch (PPM) and elevated gradients after aortic valve in valve (ViV), and to evaluate predictors and associations with clinical outcomes of this adverse event. A total of 910 aortic ViV patients were investigated. Elevated residual gradients were defined as ≥20 mm Hg. PPM was identified based on the indexed effective orifice area (EOA), measured by echocardiography, and patient body mass index (BMI). Moderate and severe PPM (cases) were defined by European Association of Cardiovascular Imaging (EACVI) criteria and compared with patients without PPM (controls). Moderate or greater PPM was found in 61% of the patients, and severe in 24.6%. Elevated residual gradients were found in 27.9%. Independent risk factors for the occurrence of lower indexed EOA and therefore severe PPM were higher gradients of the failed bioprosthesis at baseline (unstandardised beta -0.023; 95% CI -0.032 to -0.014; P<0.001), a stented (vs a stentless) surgical bioprosthesis (unstandardised beta -0.11; 95% CI -0.161 to -0.071; P<0.001), higher BMI (unstandardised beta -0.01; 95% CI -0.013 to -0.007; P<0.001) and implantation of a SAPIEN/SAPIEN XT/SAPIEN 3 transcatheter device (unstandardised beta -0.064; 95% CI -0.095 to -0.032; P<0.001). Neither severe PPM nor elevated gradients had an association with VARC II-defined outcomes or 1-year survival (90.9% severe vs 91.5% moderate vs 89.3% none, P=0.44). Severe PPM and elevated gradients after aortic ViV are very common but were not associated with short-term survival and clinical outcomes. The long-term effect of poor post-ViV haemodynamics on clinical outcomes requires further evaluation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Review of numerical methods for simulation of the aortic root: Present and future directions
NASA Astrophysics Data System (ADS)
Mohammadi, Hossein; Cartier, Raymond; Mongrain, Rosaire
2016-05-01
Heart valvular disease is still one of the main causes of mortality and morbidity in develop countries. Numerical modeling has gained considerable attention in studying hemodynamic conditions associated with valve abnormalities. Simulating the large displacement of the valve in the course of the cardiac cycle needs a well-suited numerical method to capture the natural biomechanical phenomena which happens in the valve. The paper aims to review the principal progress of the numerical approaches for studying the hemodynamic of the aortic valve. In addition, the future directions of the current approaches as well as their potential clinical applications are discussed.
Tang, Y F; Han, L; Lu, F L; Song, Z G; Lang, X L; Zou, L J; Xu, Z Y
2016-07-01
To summarize the results and methods of left subclavian artery revascularization by stented trunk fenestration for acute Stanford type A aortic dissection. Clinical data of 67 patients (54 male and 13 female, mean age of (50±10) years) underwent surgical treatment of left subclavian artery fenestration for acute Stanford A aortic dissection in Department of Cardiothoracic Surgery, Changhai Hospital, Second Military Medical College between September 2008 and December 2014 were analyzed retrospectively. The origin of the left subclavian artery was in the true lumen and no dissection existed near the artery's starting. There were 18 cases of Marfan's syndrome. Preoperative echocardiography showed moderate to severe aortic regurgitation in 10 cases, and mitral regurgitation in 3 cases. Electrocardiogram showed myocardial ischemia in 5 cases. Three patients had acute impaired renal function. All the patients received total arch replacement combined with stented elephant trunk implantation. Left subclavian artery revascularization was performed by stented trunk fenestration as follows: firstly, stented elephant trunk was implanted to completely cover the left subclavian artery, then part of stented trunk's polyester lining was removed which is located at the origin of left subclavian artery. Aortic root procedures included aortic valve replacement in 2 cases, Bentall procedure in 21 cases and aortic valve sparing in 44 cases. Three patients received mitral valve repair and 6 patients received coronary artery bypass grafting. The cardiopulmonary bypass time, cross-clamp time, and circulatory arrest time were (179±32) minutes, (112±25) minutes, and (26±10) minutes, respectively. The in-hospital mortality was 7.5% (5/67): 2 patients died of multiple organ failure, 1 patient died of acute renal failure and another 2 patients died of severe infection shock. Two patients required reexploration for root bleeding. Transient neurology dysfunction developed in 6 patients. Six patients received tracheotomy and prolonged ventilation due to pulmonary infection. All patients discharged from the hospital were followed up for 1 to 5 years. During long-term follow-up, the survival rate was 100% and 89.8% at 1 and 5 years, respectively. CT angiography was performed once per year after discharged. The left subclavian artery perfusion was good. No dissection or anastomosis leakage was identified in any case. Stroke and left limb ischemia did not develope. For acute Stanford type A aortic dissection whose origin of the left subclavian artery is in the true lumen and no dissection existed near the artery's starting, the left subclavian artery revascularization by stented trunk fenestration technique during total arch replacement combined with stented elephant trunk implantation is reliable and effective.
Removable partial overdentures with natural root structure and osseointegrated fixtures.
Jackson, T R
1990-10-01
The development and refinement of osseointegration have had primary impetus in treatment of the totally edentulous patient. The same principles, however, may be applied to the partially edentulous patient. Osseointegrated fixtures used in conjunction with mechanical or magnetic attachments may be used to construct partial or full overdentures. This allows treatment with removable prosthodontics in many cases in which it is not practical to achieve anchorage for a fixed prosthesis.
Rönnerfalk, Mattias; Tamás, Éva
2015-07-01
The emerging new treatment options for aortic valve disease call for more sophisticated diagnostics. We aimed to describe the echocardiographic pathophysiology and characteristics of the purely regurgitant aortic valve in detail. Twenty-nine men, with chronic aortic regurgitation without concomitant heart disease referred for aortic valve intervention, underwent 2D transoesophageal echocardiographic (TEE) examination prior to surgery according to a previously published matrix. Measurements of the aortic valve apparatus in long and short axis view were made in systole and diastole and analysed off-line. The aortic valves were grouped as tricuspid (TAV) or bicuspid (BAV), and classified by regurgitation mechanism. Twenty-four examinations were eligible for analysis of which 13 presented TAV and 11 BAV. The regurgitation mechanism was classified as dilatation of the aorta in 6 cases, as prolapse in 11 cases and as poor cusp tissue quality or quantity in 7 cases. The ventriculo-aortic junction (VAJ) and valve opening were closely related (TAV r = 0.5, BAV r = 0.73) but no correlation was found between the VAJ and the maximal sinus diameter (maxSiD) or the sinotubular junction (STJ). However, the STJ and maxSiD were significantly related (TAV vs BAV: systole r = 0.9, r = 0.8; diastole r = 0.9, r = 0.7), forming an entity. The conjoined BAV cusps were shorter than the anterior cusps when closed (P = 0.002); the inter-commissural distances of the cusps in the BAV group were significantly different (P = 0.001 resp. 0.03) in both systole and diastole. The VAJ was independent of other aortic dimensions and should thereby be considered as a separate entity with influence on valve opening. The detailed 2D TEE measurements of this study add further important information to our knowledge about the function and echocardiographic anatomy of the pathological aortic valve and root either as a stand-alone examination or as a benchmark and complement to 3D echocardiography. This may have an impact on decisions regarding repairability of the native aortic valve. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Echocardiographic aortic valve calcification and outcomes in women and men with aortic stenosis
Thomassen, Henrik K; Cioffi, Giovanni; Gerdts, Eva; Einarsen, Eigir; Midtbø, Helga Bergljot; Mancusi, Costantino; Cramariuc, Dana
2017-01-01
Objective Sex differences in risk factors of aortic valve calcification (AVC) by echocardiography have not been reported from a large prospective study in aortic stenosis (AS). Methods AVC was assessed using a prognostically validated visual score and grouped into none/mild or moderate/severe AVC in 1725 men and women with asymptomatic AS in the Simvastatin Ezetimibe in Aortic Stenosis study. The severity of AS was assessed by the energy loss index (ELI) taking pressure recovery in the aortic root into account. Results More men than women had moderate/severe AVC at baseline despite less severe AS by ELI (p<0.01). Moderate/severe AVC at baseline was independently associated with lower aortic compliance and more severe AS in both sexes, and with increased high-sensitive C reactive protein (hs-CRP) only in men (all p<0.01). In Cox regression analyses, moderate/severe AVC at baseline was associated with a 2.5-fold (95% CI 1.64 to 3.80) higher hazard rate of major cardiovascular events in women, and a 2.2-fold higher hazard rate in men (95% CI 1.54 to 3.17) (both p<0.001), after adjustment for age, hypertension, study treatment, aortic compliance, left ventricular (LV) mass and systolic function, AS severity and hs-CRP. Moderate/severe AVC at baseline also predicted a 1.8-fold higher hazard rate of all-cause mortality in men (95% CI 1.04 to 3.06, p<0.05) independent of age, AS severity, LV mass and aortic compliance, but not in women. Conclusion In conclusion, AVC scored by echocardiography has sex-specific characteristics in AS. Moderate/severe AVC is associated with higher cardiovascular morbidity in both sexes, and with higher all-cause mortality in men. Trial registration number ClinicalTrials.gov identifier: NCT00092677 PMID:28698175
Echocardiographic aortic valve calcification and outcomes in women and men with aortic stenosis.
Thomassen, Henrik K; Cioffi, Giovanni; Gerdts, Eva; Einarsen, Eigir; Midtbø, Helga Bergljot; Mancusi, Costantino; Cramariuc, Dana
2017-10-01
Sex differences in risk factors of aortic valve calcification (AVC) by echocardiography have not been reported from a large prospective study in aortic stenosis (AS). AVC was assessed using a prognostically validated visual score and grouped into none/mild or moderate/severe AVC in 1725 men and women with asymptomatic AS in the Simvastatin Ezetimibe in Aortic Stenosis study. The severity of AS was assessed by the energy loss index (ELI) taking pressure recovery in the aortic root into account. More men than women had moderate/severe AVC at baseline despite less severe AS by ELI (p<0.01). Moderate/severe AVC at baseline was independently associated with lower aortic compliance and more severe AS in both sexes, and with increased high-sensitive C reactive protein (hs-CRP) only in men (all p<0.01). In Cox regression analyses, moderate/severe AVC at baseline was associated with a 2.5-fold (95% CI 1.64 to 3.80) higher hazard rate of major cardiovascular events in women, and a 2.2-fold higher hazard rate in men (95% CI 1.54 to 3.17) (both p<0.001), after adjustment for age, hypertension, study treatment, aortic compliance, left ventricular (LV) mass and systolic function, AS severity and hs-CRP. Moderate/severe AVC at baseline also predicted a 1.8-fold higher hazard rate of all-cause mortality in men (95% CI 1.04 to 3.06, p<0.05) independent of age, AS severity, LV mass and aortic compliance, but not in women. In conclusion, AVC scored by echocardiography has sex-specific characteristics in AS. Moderate/severe AVC is associated with higher cardiovascular morbidity in both sexes, and with higher all-cause mortality in men. ClinicalTrials.gov identifier: NCT00092677. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Quantification of motion of the thoracic aorta after ascending aortic repair of type-A dissection.
Suh, Ga-Young; Fleischmann, Dominik; Beygui, Ramin E; Cheng, Christopher P
2017-05-01
To quantify cardiac and respiratory deformations of the thoracic aorta after ascending aortic graft repair. Eight patients were scanned with cardiac-resolved computed tomography angiography during inspiratory/expiratory breath-holds. Aortic centerlines and lumen were extracted to compute the arclength, curvature, angulation, and cross-section shape. From systole to diastole, the angle of graft [Formula: see text] arch increased by 2.4[Formula: see text] ± 1.8[Formula: see text] (P < 0.01) and the angle of arch [Formula: see text] descending aorta decreased by 2.4[Formula: see text] ± 2.6[Formula: see text] (P < 0.05), while the effective diameter of the proximal arch decreased by 2.4 ± 1.9% (P < 0.01), a greater change than those of the graft or distal arch (P < 0.05). From inspiration to expiration, the angle of graft [Formula: see text] arch increased by 2.8[Formula: see text] ± 2.6[Formula: see text] (P < 0.02) with the peak curvature increase (P < 0.05). Shorter graft length was correlated with greater cardiac-induced graft [Formula: see text] arch angulation, and longer graft length was correlated with greater respiratory-induced arch [Formula: see text] descending aorta angulation (R [Formula: see text] 0.50). The thoracic aorta changed curvature and angulation with cardiac and respiratory influences, driven by aortic root and arch motion. The thoracic aortic geometry and deformation are correlated with the ascending aortic graft length.
2014-01-01
Background Bicuspid aortic valve (BAV) is the most frequent congenital heart disease with frequent involvement in thoracic aortic dilatation, aneurysm and dissection. Although BAV and Marfan syndrome (MFS) share some clinical features, and some MFS patients with BAV display mutations in FBN1, the gene encoding fibrillin-1, the genetic background of isolated BAV is poorly defined. Methods Ten consecutive BAV patients [8 men, age range 24–42 years] without MFS were clinically characterized. BAV phenotype and function, together with evaluation of aortic morphology, were comprehensively assessed by Doppler echocardiography. Direct sequencing of each FBN1 exon with flanking intron sequences was performed on eight patients. Results We detected three FBN1 mutations in two patients (aged 24 and 25 years) displaying aortic root aneurysm ≥50 mm and moderate aortic regurgitation. In particular, one patient had two mutations (p.Arg2726Trp and p.Arg636Gly) one of which has been previously associated with variable Marfanoid phenotypes. The other patient showed a pArg529Gln substitution reported to be associated with an incomplete MFS phenotype. Conclusions The present findings enlarge the clinical spectrum of isolated BAV to include patients with BAV without MFS who have involvement of FBN1 gene. These results underscore the importance of accurate phenotyping of BAV aortopathy and of clinical characterization of BAV patients, including investigation of systemic connective tissue manifestations and genetic testing. PMID:24564502
Moreno, Raúl; Calvo, Luis; Sánchez-Recalde, Angel; Galeote, Guillermo; Jiménez-Valero, Santiago; López, Teresa; Plaza, Ignacio; González-Davia, Rosa; Ramírez, Ulises; Mesa, Jose Maria; Moreno-Gomez, Isidro; López-Sendón, José-Luis
2015-11-01
A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.
Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
Dwyer, Harry A; Matthews, Peter B; Azadani, Ali; Jaussaud, Nicolas; Ge, Liang; Guy, T Sloane; Tseng, Elaine E
2009-08-01
Studied under clinical trials, transcatheter aortic valves (TAV) have demonstrated good short-term feasibility and results in high-risk surgical patients with severe aortic stenosis. However, their long-term safety and durability are unknown. The objective of this study is to evaluate hemodynamic changes within TAV created by bioprosthetic leaflet degeneration. Computational fluid dynamics (CFD) simulations were performed to evaluate the hemodynamics through TAV sclerosis (35% orifice reduction) and stenosis (78% orifice reduction). A three-dimensional surface mesh of the TAV within the aortic root was generated for each simulation. Leaflets were contained within an open, cylindrical body without attachment to the sinus commissures representing the stent. A continuous surface between the annulus and TAV excluded the geometry of the native calcified leaflets and prevented paravalvular leak. Unsteady control volume analysis throughout systole was used to calculate leaflet shear stress and total force on the TAV. Sclerosis increased total force on the TAV by 63% (0.602-0.98 N). Advancement of degeneration from sclerosis to stenosis was accompanied by an 86% increase in total force (1.82 N) but only a 32% increase in peak wall shear stress on the leaflets. Of the total force exerted on the TAV, 99% was in the direction of axial flow. Shear stresses on the TAV were greatest during peak systolic flow with stress concentrations on the tips of the leaflets. In the normal TAV, the aortic root geometry and physiologic flow dominate location and magnitude of shear stress. Following leaflet degeneration, the specific geometry of the stenosis dictates the profile of axial velocity leaving the TAV and shear stress on the leaflets. A dramatic increase in peak leaflet shear stress was observed (115 Pa stenosis vs. 87 Pa sclerosis and 29 Pa normal). CFD simulations in this study provide the first of its kind data quantifying hemodynamics within stenosed TAV. Stenosis leads to significant forces of TAV during systole; however, diastolic forces predominate even with significant stenosis. Substantial changes in peak shear stress occur with TAV degeneration. As the first implanted TAV begin to stenose, the authors recommend watchful examination for device failure.
Ross operation in children: late results.
Elkins, R C; Lane, M M; McCue, C
2001-11-01
Although the Ross operation has become the accepted aortic valve replacement in children, the long-term fate of the pulmonary autograft valve remains unknown. To assess mid-term and late results of autograft valve durability, patient survival and valve-related morbidity, a retrospective review of patients (age range: 3 days to 17 years) having a Ross operation between November 1986 and May 2001 were reviewed. Medical records and patient contacts with all but two of 167 current survivors of 178 consecutive patients having an aortic valve replacement as a Ross operation have been completed during the past two years. The most recent echocardiographic evaluation was reviewed for autograft valve and homograft valve function. Operative mortality was 4.5% (8/178), with three late deaths (two were non-valve-related) for an actuarial survival of 92+/-3% at 12 years. Actuarial freedom from autograft valve degeneration (reoperation or severe insufficiency of autograft valve or valve-related death) was 90+/-4% at 12 years. Autograft valve degeneration was not affected by technique of insertion (141 root replacement, 37 intra-aortic), aortic valve morphology (157 bicuspid or unicuspid, 26 tricuspid), or age at operation. Autograft valve degeneration was worse in patients with a primary lesion of aortic insufficiency than in those with aortic stenosis (p = 0.03). Autograft valve reoperation was required in 12 patients, with autograft valve replacement in seven. Actuarial freedom from autograft replacement was 93+/-3% at 12 years. Homograft valve replacement was required in seven patients, with actuarial freedom from replacement of 90+/-4% at 12 years. Eight additional patients have homograft valve obstruction (gradient > or =50 mmHg), and seven have severe pulmonary insufficiency. Survival and freedom from aortic valve replacement are excellent in children. Homograft valve late function remains a concern, and efforts to improve homograft durability should be encouraged.
Veldhoen, Simon; Behzadi, Cyrus; Derlin, Thorsten; Rybczinsky, Meike; von Kodolitsch, Yskert; Sheikhzadeh, Sara; Henes, Frank Oliver; Bley, Thorsten Alexander; Adam, Gerhard; Bannas, Peter
2015-03-01
To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients.
Stokke, Thomas M; Ruddox, Vidar; Sarvari, Sebastian I; Otterstad, Jan E; Aune, Erlend; Edvardsen, Thor
2014-11-01
Physical examination and auscultation can be challenging for medical students. The aim of this study was to investigate whether a brief session of group training in focused cardiac ultrasound (FCU) with a pocket-sized device would allow medical students to improve their ability to detect clinically relevant cardiac lesions at the bedside. Twenty-one medical students in their clinical curriculum completed 4 hours of FCU training in groups. The students examined patients referred for echocardiography with emphasis on auscultation, followed by FCU. Findings from physical examination and FCU were compared with those from standard echocardiography performed and analyzed by cardiologists. In total, 72 patients were included in the study, and 110 examinations were performed. With a stethoscope, sensitivity to detect clinically relevant (moderate or greater) valvular disease was 29% for mitral regurgitation, 33% for aortic regurgitation, and 67% for aortic stenosis. FCU improved sensitivity to detect mitral regurgitation (69%, P < .001). However, sensitivity to detect aortic regurgitation (43%) and aortic stenosis (70%) did not improve significantly. Specificity was ≥89% for all valvular diagnoses by both methods. For nonvalvular diagnoses, FCU's sensitivity to detect moderate or greater left ventricular dysfunction (90%) was excellent, detection of right ventricular dysfunction (79%) was good, while detection of dilated left atrium (53%), dilated right atrium (49%), pericardial effusion (40%), and dilated aortic root (25%) was less accurate. Specificity varied from 57% to 94%. After brief group training in FCU, medical students could detect mitral regurgitation significantly better compared with physical examination, whereas detection of aortic regurgitation and aortic stenosis did not improve. Left ventricular dysfunction was detected with high sensitivity. More extensive training is advised. Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Motomura, Noboru; Miyata, Hiroaki; Tsukihara, Hiroyuki; Takamoto, Shinichi
2008-09-30
The objective of this study was to collect integrated data from nationwide hospitals using a web-based national database system to build up our own risk model for the outcome from thoracic aortic surgery. The Japan Adult Cardiovascular Surgery Database was used; this involved approximately 180 hospitals throughout Japan through a web-based data entry system. Variables and definitions are almost identical to the STS National Database. After data cleanup, 4707 records were analyzed from 97 hospitals (between January 1, 2000, and December 31, 2005). Mean age was 66.5 years. Preoperatively, the incidence of chronic lung disease was 11%, renal failure was 9%, and rupture or malperfusion was 10%. The incidence of the location along the aorta requiring replacement surgery (including overlapping areas) was: aortic root, 10%; ascending aorta, 47%; aortic arch, 44%; distal arch, 21%; descending aorta, 27%; and thoracoabdominal aorta, 8%. Raw 30-day and 30-day operative mortality rates were 6.7% and 8.6%, respectively. Postoperative incidence of permanent stroke was 6.1%, and renal failure requiring dialysis was 6.7%. OR for 30-day operative mortality was as follows: emergency or salvage, 3.7; creatinine >3.0 mg/dL, 3.0; and unexpected coronary artery bypass graft, 2.6. As a performance metric of the risk model, C-index of 30-day and 30-day operative mortality was 0.79 and 0.78, respectively. This is the first report of risk stratification on thoracic aortic surgery using a nationwide surgical database. Although condition of these patients undergoing thoracic aortic surgery was much more serious than other procedures, the result of this series was excellent.
Prosthetic valve endocarditis due to Propionibacterium acnes.
van Valen, Richard; de Lind van Wijngaarden, Robert A F; Verkaik, Nelianne J; Mokhles, Mostafa M; Bogers, Ad J J C
2016-07-01
To study the characteristics of patients with Propionibacterium acnes prosthetic valve endocarditis (PVE) who required surgery. A single-centre retrospective cohort study was conducted during a 7-year period. Patients with definite infective P. acnes endocarditis, according to the modified Duke criteria, were included. An extended culture protocol was applied. Information on medical health status, surgery, antibiotic treatment and mortality was obtained. Thirteen patients fulfilled the criteria for P. acnes endocarditis (0.53% of 2466 patients with valve replacement in a 7-year period). All patients were male and had a previous valve replacement. The health status of patients was poor at diagnosis of P. acnes PVE. Most patients (11 of 13, 85%) were admitted with signs of heart failure due to a significant paravalvular leak; 2 of 13 (15%) patients presented with septic emboli. Twelve patients needed redo surgery, whereas one could be treated with antibiotic therapy only. The time between the index surgery and presentation with P. acnes PVE varied between 5 and 135 months (median 26.5 months). Replacement and reconstruction of the dysfunctional valve and affected anatomical structures was mainly performed with a mechanical valve (n = 5, 42%) or a (bio-) Bentall prosthesis (n = 6, 50%). Antibiotic therapy consisted of penicillin with or without rifampicin for 6 weeks after surgery. The mortality in this series was low (n = 1, 8%) and no recurrent endocarditis was found during a median follow-up of 38 months. Propionibacterium acnes PVE is a rare complication after valve surgery. Redo surgery is often required. Treatment of the dysfunctional prosthetic aortic valve most often consists of root replacement, in combination with antibiotic therapy. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Pasta, S; Gentile, G; Raffa, G M; Bellavia, D; Chiarello, G; Liotta, R; Luca, A; Scardulla, C; Pilato, M
2017-08-01
The development of ascending aortic dilatation in patients with bicuspid aortic valve (BAV) is highly variable, and this makes surgical decision strategies particularly challenging. The purpose of this study was to identify new predictors, other than the well established aortic size, that may help to stratify the risk of aortic dilatation in BAV patients. Using fluid-structure interaction analysis, both haemodynamic and structural parameters exerted on the ascending aortic wall of patients with either BAV (n = 21) or tricuspid aortic valve (TAV; n = 13) with comparable age and aortic diameter (42.7 ± 5.3 mm for BAV and 45.4 ± 10.0 mm for TAV) were compared. BAV phenotypes were stratified according to the leaflet fusion pattern and aortic shape. Systolic wall shear stress (WSS) of BAV patients was higher than TAV patients at the sinotubular junction (6.8 ± 3.3 N/m 2 for BAV and 3.9 ± 1.3 N/m 2 for TAV; p = .006) and mid-ascending aorta (9.8 ± 3.3 N/m 2 for BAV and 7.1 ± 2.3 N/m 2 for TAV; p = .040). A statistically significant difference in BAV versus TAV was also observed for the intramural stress along the ascending aorta (e.g., 2.54 × 10 5 ± 0.32 × 10 5 N/m 2 for BAV and 2.04 × 10 5 ± 0.34 × 10 5 N/m 2 for TAV; p < .001) and pressure index (0.329 ± 0.107 for BAV and 0.223 ± 0.139 for TAV; p = .030). Differences in the BAV phenotypes (i.e., BAV type 1 vs. BAV type 2) and aortopathy (i.e., isolated tubular vs. aortic root dilatations) were associated with asymmetric WSS distributions in the right anterior aortic wall and right posterior aortic wall, respectively. These findings suggest that valve mediated haemodynamic and structural parameters may be used to identify which regions of aortic wall are at greater stress and enable the development of a personalised approach for the diagnosis and management of aortic dilatation beyond traditional guidelines. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Ross operation: 16-year experience.
Elkins, Ronald C; Thompson, David M; Lane, Mary M; Elkins, C Craig; Peyton, Marvin D
2008-09-01
We performed a review of a consecutive series of 487 patients undergoing the Ross operation to identify surgical techniques and clinical parameters that affect outcome. We performed a prospective review of consecutive patients from August 1986 through June 2002 and follow-up through August 2004. Patient age was 2 days to 62 years (median, 24 years), and 197 patients were less than 18 years of age. The Ross operation was performed as a scalloped subcoronary implant in 26 patients, an inclusion cylinder in 54 patients, root replacement in 392 patients, and root-Konno procedure in 15 patients. Clinical follow-up in 96% and echocardiographic evaluation in 77% were performed within 2 years of closure. Actuarial survival was 82% +/- 6% at 16 years, and hospital mortality was 3.9%. Freedom from autograft failure (autograft reoperation and valve-related death) was 74% +/- 5%. Male sex and primary diagnosis of aortic insufficiency (no prior aortic stenosis) were significantly associated with autograft failure by means of multivariate analysis. Freedom from autograft valve replacement was 80% +/- 5%. Freedom from endocarditis was 95% +/- 2%. One late thromboembolic episode occurred. Freedom from allograft reoperation or reintervention was 82% +/- 4%. Freedom from all valve-related events was 63% +/- 6%. In children survival was 84% +/- 8%, and freedom from autograft valve failure was 83% +/- 6%. The Ross operation provides excellent survival in adults and children willing to accept a risk of reoperation. Male sex and a primary diagnosis of aortic insufficiency had a negative effect on late results.
Aortic root dilation in kidney transplant recipients.
Obremska, Marta; Boratyńska, Maria; Szymczak, Maciej; Zyśko, Dorota; Płonek, Tomasz; Goździk, Anna; Klinger, Marian
2018-05-30
INTRODUCTION Aortic root (AoR) dilation is associated with cardiac damage and higher cardiovascular risk. Cardiovascular disease is the most common cause of death in patients after kidney transplantation (KTx ). OBJECTIVES The aim of this study was to assess the prevalence of enlarged AoR diameter in KTx recipients. Patients with bicuspid aortic valve, significant valvular disease, or evidence of connective tissue disorder were excluded. PATIENTS AND METHODS A total of 87 KTx recipients were divided into 2 groups depending on immunosuppressive regimen: 41 patients receiving mammalian target of rapamycin inhibitors (mTORi) and 46 patients treated with calcineurin inhibitors (CNIs). In all patients, echocardiography was performed, laboratory and clinical markers of cardiovascular risk were assessed, and the AoR diameter was calculated. RESULTS There were no differences between groups in age, sex, body surface area, body mass index, frequency of diabetes, hypertension, dyslipidemia, time after replacement therapy, creatinine levels, and estimated glomerular filtration rate. In the CNI group, the observed and calculated AoR diameters were similar (P = 0.8). In the mTORi group, the observed AoR diameter was higher than the calculated one (P = 0.002). The concentric and eccentric left ventricular hypertrophy was similar in both groups (P = 0.12 and P = 0.69, respectively). In the stepwise regression analysis, the AoR diameter was associated with body surface area and mTORi treatment. CONCLUSIONS KTx recipients have a high prevalence of AoR dilation. Immunosuppressive regimen based on mTORi increases the incidence of AoR enlargement.
CANNULATION STRATEGY FOR AORTIC ARCH RECONSTRUCTION USING DEEP HYPOTHERMIC CIRCULATORY ARREST
de Zéicourt, Diane; Jung, Philsub; Horner, Marc; Pekkan, Kerem; Kanter, Kirk R.; Yoganathan, Ajit P.
2013-01-01
Background Aortic arch reconstruction in neonates is commonly performed using deep hypothermic circulatory arrest. However, concerns have arisen regarding potential adverse neurologic outcomes from this complex procedure, raising questions as to best arterial cannulation approach for cerebral perfusion and effective systemic hypothermia. In this study, we use computational fluid dynamics to investigate the impact of different cannulation strategies in neonates. Methods Using a realistic hypoplastic neonatal aorta template as the base geometry, four different cannulation options were investigated: 1) right innominate artery, 2) innominate root, 3) patent ductus arteriosus (PDA), or 4) both innominate root and PDA. Performance was evaluated based on the numerically predicted cerebral and systemic flow distributions compared with physiological perfusion under neonatal conditions. Results The four cannulation strategies were associated with different local hemodynamics, but this did not translate into any significant effect on the measured flow distributions. The largest difference only represented 0.8% of the cardiac output and was measured in the innominate artery, which received 23.2% of the cardiac output in Option 3 vs. 24% in Option 4. PA snaring benefited all systemic vessels uniformly. Conclusion Due to the very high vascular resistances in neonates, flow distribution to the different vascular beds was dictated by the downstream vascular resistances rather than the cannulation strategy, allowing the surgical team to choose their method of preference. However, patients with aortic coarctation warrant further investigation and will most likely benefit from a two cannulae approach (Option 4). PMID:22608717
Brown, Amanda L.; Zhu, Xuewei; Rong, Shunxing; Shewale, Swapnil; Seo, Jeongmin; Boudyguina, Elena; Gebre, Abraham K.; Alexander-Miller, Martha A.; Parks, John S.
2012-01-01
Objective Fish oil (FO), containing n-3 fatty acids (FAs), attenuates atherosclerosis. We hypothesized that n-3 FA-enriched oils are atheroprotective through alteration of monocyte subsets and their trafficking into atherosclerotic lesions. Methods and Results Low density lipoprotein receptor knockout (LDLr−/−) and apolipoprotein E−/− (apoE) mice were fed diets containing 10% (calories) as palm oil (PO) and 0.2% cholesterol, supplemented with an additional 10% PO, echium oil (EO; containing 18:4 n-3) or FO. Compared to PO-fed LDLr−/− mice, EO and FO significantly reduced plasma cholesterol, splenic Ly6Chi monocytosis by ~50%, atherosclerosis by 40–70%, monocyte trafficking into the aortic root by ~50%, and atherosclerotic lesion macrophage content by 30–44%. In contrast, atherosclerosis and monocyte trafficking into the artery wall was not altered by n-3 FAs in apoE−/− mice; however, Ly6Chi splenic monocytes positively correlated with aortic root intimal area across all diet groups. In apoE−/− mice, FO reduced the percentage of blood Ly6Chi monocytes, despite an average two-fold higher plasma cholesterol relative to PO. Conclusions The presence of splenic Ly6Chi monocytes parallels the appearance of atherosclerotic disease in both LDLr−/− and apoE−/− mice. Furthermore, n-3 FAs favorably alter monocyte subsets independently from effects on plasma cholesterol, and reduce monocyte recruitment into atherosclerotic lesions. PMID:22814747
Stanger, Olaf; Bleuel, Irina; Gisler, Fabian; Göber, Volkhard; Reineke, Sylvia; Gahl, Brigitta; Aymard, Thierry; Englberger, Lars; Carrel, Thierry; Tevaearai, Hendrik
2015-07-01
To report our institutional experience and long-term results with the Freedom Solo bovine pericardial stentless bioprosthesis (Sorin Group, Saluggia, Italy). Between January 2005 and November 2009, 149 patients (mean age, 73.6 ± 8.7 years; 68 [45.6%] female) underwent isolated (n = 75) or combined (n = 74) aortic valve replacement (AVR) using the Solo in our institution. Follow-up was 100% complete with an average follow-up time of 5.9 ± 2.6 years (maximum, 9.6 years) and a total of 885.3 patient years. Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n = 1] and 4.0% for combined procedures [n = 3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2 ± 23.0 mm Hg (48.6 ± 16.3 mm Hg) decreased to 15.6 ± 5.4 mm Hg (8.8 ± 3.0 mm Hg) after AVR, and remained low for up to 9 years. The postoperative effective orifice area was 1.6 ± 0.57 cm(2), 1.90 ± 0.45 cm(2), 2.12 ± 0.48 cm(2), and 2.20 ± 0.66 cm(2) for the valve sizes 21, 23, 25, and 27, respectively, with absence of severe prosthesis-patient mismatch and 0.7% (n = 1) experienced moderate prosthesis-patient mismatch. During follow-up, 26 patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation, and SVD at 9 years averaged 0.57 (range, 0.47-0.66), 0.82 (range, 0.69-0.90), and 0.70 (range, 0.57-0.79), respectively. The Freedom Solo stentless aortic valve is safe to implant and shows excellent early and midterm hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5-6 years and the need for explantation increased markedly, suggesting low durability. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Ius, Fabio; Fleissner, Felix; Pichlmaier, Maximilian; Karck, Matthias; Martens, Andreas; Haverich, Axel; Shrestha, Malakh
2013-11-01
Since August 2001, the frozen elephant trunk (FET) technique has been used at our institution to treat degenerative or dissecting aneurysms involving the aortic arch and descending aorta as a potential 'single-stage' procedure. The aim of this study was to review our FET experience and to present the 10-year results. Between August 2001 and January 2012, 131 patients underwent FET implant with three different prostheses: the custom-made Chavan-Haverich (n = 66), the Jotec E-vita (n = 30) and the Vascutek Thoraflex (n = 35) prostheses. Concomitant procedures included aortic valve-sparing operations (David, n = 17) and aortic root replacement (Bentall, n = 25). Patient records and the first postoperative and last available computer tomography (CT) were retrospectively reviewed. Incidence of rethoracotomy for bleeding, stroke, spinal cord injury, prolonged ventilatory support (>96 h) and acute renal failure requiring dialysis were 18, 11, 1, 41 and 16%, respectively. In-hospital mortality was 15%. The mean follow-up was 42 ± 37 (range 1-134 months). At 1, 5 and 10 years, survivals were 82 ± 3, 72 ± 5 and 58 ± 8%, respectively. Freedoms from distal aortic operation were 81 ± 4, 67 ± 5 and 43 ± 13%, respectively. Thirty-six patients underwent 40 distal aortic operations, either open surgical (n = 22, 55%) or endovascular (n = 18, 45%). Chronic aortic dissection was identified as an independent risk factor for distal aortic operation (odds ratio = 3.8; 95% confidence interval 1.5-9.3; P = 0.004). At last CT control, false-lumen thrombosis rates up to 93% were achieved around the stent graft. An FET concept adds to the armament of the surgeon in the treatment of complex and diverse aortic arch pathologies. The preoperative patient risk profile explains the postoperative morbidity and in-hospital mortality. The FET can potentially be still a 'one-stage' procedure in selected patients. However, the extension of FET to patients with extensive aortic aneurysms has led to an increase in second-stage procedures.
Benz, Dominik C; Gräni, Christoph; Mikulicic, Fran; Vontobel, Jan; Fuchs, Tobias A; Possner, Mathias; Clerc, Olivier F; Stehli, Julia; Gaemperli, Oliver; Pazhenkottil, Aju P; Buechel, Ronny R; Kaufmann, Philipp A
The clinical utility of a latest generation iterative reconstruction algorithm (adaptive statistical iterative reconstruction [ASiR-V]) has yet to be elucidated for coronary computed tomography angiography (CCTA). This study evaluates the impact of ASiR-V on signal, noise and image quality in CCTA. Sixty-five patients underwent clinically indicated CCTA on a 256-slice CT scanner using an ultralow-dose protocol. Data sets from each patient were reconstructed at 6 different levels of ASiR-V. Signal intensity was measured by placing a region of interest in the aortic root, LMA, and RCA. Similarly, noise was measured in the aortic root. Image quality was visually assessed by 2 readers. Median radiation dose was 0.49 mSv. Image noise decreased with increasing levels of ASiR-V resulting in a significant increase in signal-to-noise ratio in the RCA and LMA (P < 0.001). Correspondingly, image quality significantly increased with higher levels of ASiR-V (P < 0.001). ASiR-V yields substantial noise reduction and improved image quality enabling introduction of ultralow-dose CCTA.
Echocardiographic features of the normofunctional Labcor-Santiago pericardial bioprosthesis.
Gonzalez-Juanatey, J R; Garcia-Bengoechea, J B; Vega, M; Rubio, J; Sierra, J; Duran, D; Amaro, A; Gil, M
1994-09-01
Echocardiography was performed in 94 patients with a total of 99 normally functioning Labcor-Santiago bioprostheses, 62 in the aortic and 37 in the mitral position. The following variables were measured: peak and mean transvalvular velocities, peak and mean instantaneous pressure gradients as calculated from the modified Bernoulli equation, pressure half-time, cardiac index, stroke volume and effective orifice area (using continuity and Hatle equations). Regurgitation patterns were sought by transthoracic echocardiography (all valves) and, for selected mitral bioprostheses, by transesophageal echocardiography. Calculated mean aortic pressure gradient ranged from six to 10 mmHg and calculated effective aortic orifice area increased with ring diameter, with means of 1.27 cm2 for the 19 mm valve and 2.58 cm2 for the 27 mm valve. For mitral bioprostheses, mean pressure gradient ranged from 3.0 to 4.5 mmHg and calculated effective orifice area from 2.27 to 2.73 cm2. Only central regurgitation was observed. The Labcor-Santiago pericardial bioprostheses created little resistance to forward flow. In the small aortic root their hemodynamic performance was as good or better than that of other currently available devices. It is hoped that this new design will contribute increased in vivo mechanical durability.
Caraang, Chris; El-Bialy, Adel
2004-12-01
The effective management of aortic dissection relies heavily on a high index of suspicion followed by timely definitive diagnosis. Young adults without a history of blunt trauma who are not at risk for atherosclerotic disease may lower this suspicion. We present a 24-year-old patient with complaints of chest pain who presented in multiple urgent care clinics and emergency departments. With a normal chest radiograph, he was repeatedly discharged home on analgesics until a loud murmur was heard. An echocardiogram revealed a dilated aortic root with an intimal flap consistent with a type II dissection. After surgical aortic repair with a Bentall procedure, he was discharged with complete relief of symptoms. Histologic reports revealed cystic medial degeneration. Physical examinations did not demonstrate the phenotypic manifestations of Marfan syndrome. This case illustrates the importance of cardiac auscultation when assessing an individual with chest pain, even with a low likelihood for alteration in arterial structure, and the maintenance of a high index of clinical suspicion despite a normal chest radiograph. We consider this case to be of interest because of its rarity in a 24-year-old.
Marfan syndrome and cardiovascular complications: results of a family investigation.
Sarr, Simon Antoine; Djibrilla, Siddikatou; Aw, Fatou; Bodian, Malick; Babaka, Kana; Ngaidé, Aliou Alassane; Dioum, Momar; Ba, Serigne Abdou
2017-07-19
Cardiovascular complications in Marfan syndrome (MFS) make all its seriousness. Taking as a basis the Ghent criteria, we conducted a family screening from an index case. The objective was to describe the clinical characteristics of MFS anomalies and to detect cardiovascular complications in our patients. Six subjects were evaluated. Patients had to be in the same uterine siblings of the index case or be a descendant. The objective was to search for MFS based on the diagnostic criteria of Ghent and, subsequently, detecting cardiovascular damage. The average age was 24 years. The examination revealed three cases of sudden death in a context of chest pain. Five subjects had systemic involvement with a score ≥ 7 that allowed to the diagnosis of MFS. Two patients had simultaneously ectopia lentis and myopia. In terms of cardiovascular damage, there were three cases of dilatation of the aortic root, two cases of aortic dissection of Stanford's type A with severe aortic regurgitation in one case and moderate in the other. There were three patients with moderate mitral regurgitation with a case by valve prolapse. The family screening is crucial in Marfan syndrome. It revealed serious cardiovascular complications including sudden death and aortic dissection.
Krivoshei, A; Uuetoa, H; Min, M; Annus, P; Uuetoa, T; Lamp, J
2015-08-01
The paper presents analysis of the generic transfer function (TF) between Electrical Bioimpedance (EBI) measured non-invasively on the wrist and Central Aortic Pressure (CAP) invasively measured at the aortic root. Influence of the Heart Rate (HR) variations on the generic TF and on reconstructed CAP waveforms is investigated. The HR variation analysis is provided on a single patient data to exclude inter-patient influences at the current research stage. A new approach for the generic TF estimating from a data ensemble is presented as well. Moreover, an influence of the cardiac period beginning point selection is analyzed and empirically optimal solution for its selection is proposed.
Ruivo, Catarina; Guardado, Joana; Montenegro Sá, Fernando; Saraiva, Fátima; Antunes, Alexandre; Correia, Joana; Morais, João
2017-07-01
We report a clinical case of a 40-year-old male with surgically corrected congenital heart disease (CHD) 10 years earlier: closure of ostium primum, mitral annuloplasty, and aortic valve and root surgery. The patient was admitted with acute heart failure. Transesophageal echocardiography (TEE) revealed a dysmorphic and severely incompetent aortic valve, a partial tear of the mitral valve cleft repair and annuloplasty ring dehiscence. A true left ventricular-to-right atrial shunt confirmed a direct Gerbode defect. The authors aim to discuss the diagnostic challenge of adult CHD, namely the key role of TEE on septal defects and valve regurgitations description. © 2017, Wiley Periodicals, Inc.
Musa, Tarique Al; Plein, Sven; Greenwood, John P
2016-06-01
Degenerative aortic stenosis (AS) is the most common valvular disease in the western world with a prevalence expected to double within the next 50 years. International guidelines advocate the use of cardiovascular magnetic resonance (CMR) as an investigative tool, both to guide diagnosis and to direct optimal treatment. CMR is the reference standard for quantifying both left and right ventricular volumes and mass, which is essential to assess the impact of AS upon global cardiac function. Given the ability to image any structure in any plane, CMR offers many other diagnostic strengths including full visualisation of valvular morphology, direct planimetry of orifice area, the quantification of stenotic jets and in particular, accurate quantification of valvular regurgitation. In addition, CMR permits reliable and accurate measurements of the aortic root and arch which can be fundamental to appropriate patient management. There is a growing evidence base to indicate tissue characterisation using CMR provides prognostic information, both in asymptomatic AS patients and those undergoing intervention. Furthermore, a number of current clinical trials will likely raise the importance of CMR in routine patient management. This article will focus on the incremental value of CMR in the assessment of severe AS and the insights it offers following valve replacement.