Sample records for application psar volume

  1. Comparison of Adsorption/Desorption of Volatile Organic Compounds (VOCs) on Electrospun Nanofibers with Tenax TA for Potential Application in Sampling

    PubMed Central

    Chu, Lanling; Deng, Siwei; Zhao, Renshan; Deng, Jianjun; Kang, Xuejun

    2016-01-01

    The objective of this study was to compare the adsorption/desorption of target compounds on homemade electrospun nanofibers, polystyrene (PS) nanofibers, acrylic resin (AR) nanofibers and PS-AR composite nanofibers with Tenax TA. Ten volatile organic compounds (VOCs) were analyzed by preconcentration onto different sorbents followed by desorption (thermal and solvent orderly) and analysis by capillary gas chromatography. In comparison to Tenax TA, the electrospun nanofibers displayed a significant advantage in desorption efficiency and adsorption selectivity. Stability studies were conducted as a comparative experiment between PS-AR nanofibers and Tenax TA using toluene as the model compound. No stability problems were observed upon storage of toluene on both PS-AR nanofibers and Tenax TA over 60 hours period when maintained in an ultra-freezer (−80°C). The nanofibers provided slightly better stability for the adsorbed analytes than Tenax TA under other storage conditions. In addition, the nanofibers also provided slightly better precision than Tenax TA. The quantitative adsorption of PS-AR nanofibers exhibited a good linearity, as evidenced by the 0.988–0.999 range of regression coefficients (R). These results suggest that for VOCs sampling the electrospun nanofibers can be a potential ideal adsorbent. PMID:27776140

  2. Positron Annihilation Ratio Spectroscopy (PsARS) Applied to Positronium Formation Studies

    DTIC Science & Technology

    2010-03-01

    POSITRON ANNIHILATION RATIO SPECTROSCOPY (PsARS) APPLIED TO POSITRONIUM FORMATION STUDIES THESIS...AFIT/GNE/ENP/10-M07 POSITRON ANNIHILATION RATIO SPECTROSCOPY (PsARS) APPLIED TO POSITRONIUM FORMATION STUDIES ...lifetime studies in local electric field experiments. High local electric fields can polarize a positron -electron pair, which may result in an extended

  3. CO2-Binding-Organic-Liquids-Enhanced CO2 Capture using Polarity-Swing-Assisted Regeneration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jian; Kutnyakov, Igor; Koech, Phillip K.

    A new solvent-based CO2 capture process couples the unique attributes of non-aqueous, CO2-binding organic liquids (CO2BOLs) with the newly discovered polarity-swing-assisted regeneration (PSAR) process that is unique to switchable ionic liquids. Laboratory measurements with PSAR indicate the ability to achieve a regeneration effect at 75°C comparable to that at 120°C using thermal regeneration only. Initial measurements also indicate that the kinetic behavior of CO2 release is also improved with PSAR. Abstract cleared PNWD-SA-9743

  4. A Framework for Treatment Decision Making at Prostate Cancer Recurrence.

    PubMed

    Lange, Jane M; Trock, Bruce J; Gulati, Roman; Etzioni, Ruth

    2017-11-01

    Of the 50,000 men in the US who elect for radical prostatectomy for prostate cancer, 24% to 40% will have a prostate-specific antigen (PSA) recurrence (PSA-R) within 10 years. Deciding whether to administer salvage therapy (ST) at PSA-R presents challenges, as treatment reduces the risk of progression to clinical metastasis but incurs unnecessary side effects should the man die before metastasis. We have developed a new harm-benefit framework using a clinical cohort to inform shared decision making between patients and physicians at PSA-R. Records of 1,045 Johns Hopkins University Hospital patients diagnosed between 1984 and 2013 who had PSA-R following radical prostatectomy were analyzed using marginal structural models to estimate the baseline risk of metastasis and the effect of ST (radiation therapy with or without hormone therapy) while accounting for selection into ST on the basis of PSA growth. The estimated model predicts the harm-benefit tradeoffs of ST within patient subgroups. The benefit of ST is the absolute reduction in the risk of metastasis within 10 years; the harm is the frequency of cancers that would not have metastasized in the patient's lifetime in the absence of ST (overtreatment). The adjusted hazard ratio associated with ST was 0.41 (95% CI, 0.31 to 0.55). Providing ST to all men at PSA-R reduced the risk of metastasis from 43% to 23% but led to 31% of men being overtreated (harm/benefit = 31/(43-23) = 1.6). Providing ST to men with Gleason score >7 reduced the risk of metastasis from 67% to 39%, with 13% of men being overtreated (harm/benefit = 13/(67-39) = 0.5). A quantitative framework that evaluates primary harms and benefits of ST after PSA-R will facilitate informed decision making. Immediate ST may be more appropriate in patient subgroups at elevated risk of metastasis.

  5. System and process for polarity swing assisted regeneration of gas selective capture liquids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heldebrant, David J.; Tegrotenhuis, Ward E.; Freeman, Charles J.

    A polarity swing-assisted regeneration (PSAR) process is disclosed for improving the efficiency of releasing gases chemically bound to switchable ionic liquids. Regeneration of the SWIL involves addition of a quantity of non-polar organic compound as an anti-solvent to destabilize the SWIL, which aids in release of the chemically bound gas. The PSAR decreases gas loading of a SWIL at a given temperature and increases the rate of gas release compared to heating in the absence of anti-solvent.

  6. Bench-Scale Testing and Process Performance Projections of CO2 Capture by CO2–Binding Organic Liquids (CO2BOLs) With and Without Polarity-Swing-Assisted Regeneration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Feng; Heldebrant, David J.; Mathias, Paul M.

    This manuscript provides a detailed analysis of a continuous flow, bench scale study of the CO2BOL solvent platform with and without its Polarity Swing Assisted Regeneration (PSAR). This study encompassed four months of continuous flow testing of a candidate CO2BOL with a thermal regeneration and PSAR regeneration using decane antisolvent. In both regeneration schemes, steady state capture of >90 %CO2 was achieved using simulated flue gas at acceptable L/G ratios. Aspen Plus™ modeling was performed to assess process performance compared to previous equilibrium performance projections. This paper also includes net power projections, and comparisons to DOE’s Case 10 amine baseline.

  7. Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT.

    PubMed

    Stenner, Philip; Schmidt, Bernhard; Bruder, Herbert; Allmendinger, Thomas; Haberland, Ulrike; Flohr, Thomas; Kachelriess, Marc

    2009-12-01

    Cardiac CT achieves its high temporal resolution by lowering the scan range from 2pi to pi plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the pi range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2pi] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan pn(AF) by projectionwise averaging a set of neighboring partial scans pn(P) from the same perfusion examination (typically N approximately 30 phase-correlated partial scans distributed over 20 s and n = 1, ..., N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans pn(V) from the artificial full scan pn(AF). A standard reconstruction yields the corresponding images fn(P), fn(AF), and fn(V). Subtracting the virtual partial scan image fn(V) from the artificial full scan image fn(AF) yields an artifact image that can be used to correct the original partial scan image: fn(C) = fn(P) - fn(V) + fn(AF), where fn(C) is the corrected image. The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

  8. Manned space flight nuclear system safety. Volume 3: Reactor system preliminary nuclear safety analysis. Part 1: Reference Design Document (RDD)

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The Reference Design Document, of the Preliminary Safety Analysis Report (PSAR) - Reactor System provides the basic design and operations data used in the nuclear safety analysis of the Rector Power Module as applied to a Space Base program. A description of the power module systems, facilities, launch vehicle and mission operations, as defined in NASA Phase A Space Base studies is included. Each of two Zirconium Hydride Reactor Brayton power modules provides 50 kWe for the nominal 50 man Space Base. The INT-21 is the prime launch vehicle. Resupply to the 500 km orbit over the ten year mission is provided by the Space Shuttle. At the end of the power module lifetime (nominally five years), a reactor disposal system is deployed for boost into a 990 km high altitude (long decay time) earth orbit.

  9. APT Blanket System Loss-of-Coolant Accident (LOCA) Based on Initial Conceptual Design - Case 4: External Pressurizer Surge Line Break Near Inlet Header

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamm, L.L.

    1998-10-07

    This report is one of a series of reports documenting accident scenario simulations for the Accelerator Production of Tritium (APT) blanket heat removal systems. The simulations were performed in support of the Preliminary Safety Analysis Report (PSAR) for the APT.

  10. 2018 NDIA Precision Strike Annual Review (PSAR-18)

    DTIC Science & Technology

    2018-03-20

    Director for Space and Prompt Strike, OUSD for Acquisition and Sustainment (OUSD(A&S)) 1100 DARPA OPERATIONAL FIRES: Major Amber Walker, USA, Ph.D...Program Manager , Tactical Technology Office, Defense Advanced Research Projects Agency (DARPA) 1120 TURNING EXISTING TECHNOLOGIES AND WEAPONS INTO...SURPRISING NEW CAPABILITIES—FAST: Vincent Sabio—Program Manager , Advanced Technology Programs, Strategic Capabilities Office (SCO), OUSD for

  11. Manned space flight nuclear system safety. Volume 3: Reactor system preliminary nuclear safety analysis. Part 2: Accident Model Document (AMD)

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The Accident Model Document is one of three documents of the Preliminary Safety Analysis Report (PSAR) - Reactor System as applied to a Space Base Program. Potential terrestrial nuclear hazards involving the zirconium hydride reactor-Brayton power module are identified for all phases of the Space Base program. The accidents/events that give rise to the hazards are defined and abort sequence trees are developed to determine the sequence of events leading to the hazard and the associated probabilities of occurence. Source terms are calculated to determine the magnitude of the hazards. The above data is used in the mission accident analysis to determine the most probable and significant accidents/events in each mission phase. The only significant hazards during the prelaunch and launch ascent phases of the mission are those which arise form criticality accidents. Fission product inventories during this time period were found to be very low due to very limited low power acceptance testing.

  12. Properies of the microseism wave field in Australia from three component array data

    NASA Astrophysics Data System (ADS)

    Gal, Martin; Reading, Anya; Ellingsen, Simon; Koper, Keith; Burlacu, Relu; Tkalčić, Hrvoje

    2016-04-01

    In the last two decades, ambient noise studies in the range of 1-20 seconds have predominantly focused on the analysis of source regions for Rayleigh and P waves. The theoretical excitation of these phases is well understood for primary microseisms (direct coupling of gravity waves in sloping shallow bathymetry) and secondary microseisms (wave-wave interaction) and correlates well with observations. For Love waves, the excitation mechanism in the secondary microseism band is to date unknown. It has been shown, that LQ waves can exhibit larger amplitudes than Rg waves for certain frequencies. Therefore detailed analysis of the wave field are necessary to find indications on the generation mechanism. We analyse data from two spiral-shaped arrays located in Australia, the Pilbara Array (PSAR) in the North-West and an array in South Queensland (SQspa) in the East. The two arrays are different in aperture and allow for the study of primary and secondary microseisms with SQspa and higher secondary microseisms with PSAR. We use a deconvolution enhanced beamforming approach, which is based on the CLEAN algorithm. It allows the accurate detection of weaker sources and the estimation of power levels on each component or wave type. For PSAR we evaluate 1 year of data in the frequency range of 0.35-1 Hz and find fundamental and higher mode Rg and LQ waves. For the low end of the frequency range, we find the strongest fundamental mode Rg waves to originate from multiple direction, but confined to coastline reflectors, i.e. coastlines that are perpendicular to the main swell direction, while higher mode Rg waves are mainly generated in the Great Australian Bight. For higher frequencies, the source locations of Rg waves move toward the north coast, which is closest to the array and we see an increase in the Lg phase. The majority of fundamental LQ waves are generated at the west coast of Australia and we find some agreement between low frequency Rg and LQ source locations, which becomes uncorrelated with increasing frequency. For higher mode LQ waves the generation region is in the south-west, where Australia is exposed to direct swells from the Antarctic. In the case of Rg-to-LQ power ratio, we find a frequency and backazimuth dependence. Results from SQspa allow lower frequency arrivals around the primary and secondary microseism peak to be investigated.

  13. Preliminary hazards analysis -- vitrification process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coordes, D.; Ruggieri, M.; Russell, J.

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s constructionmore » and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.« less

  14. Safety Assessment for a Surface Repository in the Chernobyl Exclusion Zone - Methodology for Assessing Disposal under Intervention Conditions - 13476

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haverkamp, B.; Krone, J.; Shybetskyi, I.

    The Radioactive Waste Disposal Facility (RWDF) Buryakovka was constructed in 1986 as part of the intervention measures after the accident at Chernobyl NPP (ChNPP). Today, RWDF Buryakovka is still being operated but its maximum capacity is nearly reached. Plans for enlargement of the facility exist since more than 10 years but have not been implemented yet. In the framework of an European Commission Project DBE Technology GmbH prepared a safety analysis report of the facility in its current state (SAR) and a preliminary safety analysis report (PSAR) based on the planned enlargement. Due to its history RWDF Buryakovka does notmore » fully comply with today's best international practices and the latest Ukrainian regulations in this area. The most critical aspects are its inventory of long-lived radionuclides, and the non-existent multi-barrier waste confinement system. A significant part of the project was dedicated, therefore, to the development of a methodology for the safety assessment taking into consideration the facility's special situation and to reach an agreement with all stakeholders involved in the later review and approval procedure of the safety analysis reports. Main aspect of the agreed methodology was to analyze the safety, not strictly based on regulatory requirements but on the assessment of the actual situation of the facility including its location within the Exclusion Zone. For both safety analysis reports, SAR and PSAR, the assessment of the long-term safety led to results that were either within regulatory limits or within the limits allowing for a specific situational evaluation by the regulator. (authors)« less

  15. CO 2 Binding Organic Liquids Gas Capture with Polarity Swing Assisted Regeneration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heldebrant, David

    This report outlines the comprehensive bench-scale testing of the CO 2-binding organic liquids (CO 2BOLs) solvent platform and its unique Polarity Swing Assisted Regeneration (PSAR). This study outlines all efforts on a candidate CO 2BOL solvent molecule, including solvent synthesis, material characterization, preliminary toxicology studies, and measurement of all physical, thermodynamic and kinetic data, including bench-scale testing. Equilibrium and kinetic models and analysis were made using Aspen Plus™. Preliminary process configurations, a technoeconomic assessment and solvent performance projections for separating CO 2 from a subcritical coal-fired power plant are compared to the U.S. Department of Energy's Case 10 monoethanolamine baseline.

  16. Effect of O/W process parameters on Crataegus azarolus L nanocapsule properties.

    PubMed

    Esmaeili, Akbar; Rahnamoun, Soraya; Sharifnia, Fariba

    2013-05-29

    Nanocapsules have many applications in the drug, cosmetic, fragrance, and food industries. In this study, Crataegus azarolus L. nanocapsules were prepared by a modified emulsion diffusion technique. In this technique a shell was first made from the polyester triblock copolymer poly(ethylene glycol)-poly(butylene adipate)-poly(ethylene glycol) (PEG-PBA-PEG) and then olive oil was set as the core of the nanocapsule by a method known as the polymer deposition solvent evaporation method. Varying amounts of C. azarolus extract, polymer, and olive oil were mixed in acetone and then added to water on a shaker. Finally, the acetone was removed by vacuuming. The size of the prepared nanocapsules were measured with a particle size analysis report (PSAR) and identified by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and nuclear magnetic resonance (NMR). Our experiments showed that the size of the nanocapsules depends on the preparation conditions, i.e., the ratio of polymer to oil and concentrations of polymer and plant extract. A ratio of 1:0.25 polymer to oil was shown to be more suitable for the formation of smaller nanocapsules of C. azarolus.

  17. Effect of O/W process parameters on Crataegus azarolus L nanocapsule properties

    PubMed Central

    2013-01-01

    Background Nanocapsules have many applications in the drug, cosmetic, fragrance, and food industries. In this study, Crataegus azarolus L. nanocapsules were prepared by a modified emulsion diffusion technique. Methods In this technique a shell was first made from the polyester triblock copolymer poly(ethylene glycol)-poly(butylene adipate)-poly(ethylene glycol) (PEG-PBA-PEG) and then olive oil was set as the core of the nanocapsule by a method known as the polymer deposition solvent evaporation method. Varying amounts of C. azarolus extract, polymer, and olive oil were mixed in acetone and then added to water on a shaker. Finally, the acetone was removed by vacuuming. Results The size of the prepared nanocapsules were measured with a particle size analysis report (PSAR) and identified by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and nuclear magnetic resonance (NMR). Conclusions Our experiments showed that the size of the nanocapsules depends on the preparation conditions, i.e., the ratio of polymer to oil and concentrations of polymer and plant extract. A ratio of 1:0.25 polymer to oil was shown to be more suitable for the formation of smaller nanocapsules of C. azarolus. PMID:23718829

  18. Pathogenetic Influences of Human Herpesvirus 8 (HHV-8) in Prostate Cancer Progression

    DTIC Science & Technology

    2012-05-25

    expression of each GOI were calculated by raising 2 to the negative value ΔΔCt for each sample. Primer sequences used were: AR-F: 5’ ATG GTG AGC AGA... GTG CCC TAT C 3’ AR- R: 5’ ATG GTC CCT GGC AGT CTC CAA A 3’ PSA-F: CGC AAG TTC ACC CTC AGA AGG T 3’ PSA-R: 5’ GAC GTG ATA CCT TGA AGC ACA CC 3’ MSMB-F...TGG CGT TCC AGG GAC TCA T 3’ Zeb1-F: 5’ GGC ATA CAC CTA CTC AAC TAC GG 3’ Zeb1-R: 5’ TGG GCG GTG TAG AAT CAG AGT C 3’ Snail-F: 5’ TGC CCT CAA GAT

  19. CO2-Binding Organic Liquids Gas Capture with Polarity-Swing-Assisted Regeneration Full Technology Feasibility Study B1 - Solvent-based Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heldebrant, David J

    PNNL, Fluor Corporation and Queens University (Kingston, ON) successfully completed a three year comprehensive study of the CO2BOL water-lean solvent platform with Polarity Swing Assisted Regeneration (PSAR). This study encompassed solvent synthesis, characterization, environmental toxicology, physical, thermodynamic and kinetic property measurements, Aspen Plus™ modeling and bench-scale testing of a candidate CO2BOL solvent molecule. Key Program Findings The key program findings are summarized as follows: • PSAR favorably reduced stripper duties and reboiler temperatures with little/no impact to absorption column • >90% CO2 capture was achievable at reasonable liquid-gas ratios in the absorber • High rich solvent viscosities (up to 600more » cP) were successfully demonstrated in the bench-scale system. However, the projected impacts of high viscosity to capital cost and operational limits compromised the other levelized cost of electricity benefits. • Low thermal conductivity of organics significantly increased the required cross exchanger surface area, and potentially other heat exchange surfaces. • CO2BOL had low evaporative losses during bench-scale testing • There was no evidence of foaming during bench scale testing • Current CO2BOL formulation costs project to be $35/kg • Ecotoxicity (Water Daphnia) was comparable between CO2BOL and MEA (169.47 versus 103.63 mg/L) • Full dehydration of the flue gas was determined to not be economically feasible. However, modest refrigeration (13 MW for the 550 MW reference system) was determined to be potentially economically feasible, and still produce a water-lean condition for the CO2BOLs (5 wt% steady-state water loading). • CO2BOLs testing with 5 wt% water loading did not compromise anhydrous performance behavior, and showed actual enhancement of CO2 capture performance. • Mass transfer of CO2BOLs was not greatly impeded by viscosity • Facile separation of antisolvent from lean CO2BOL was demonstrated on the bench cart • No measurable solvent degradation was observed over 4 months of testing – even with 5 wt% water present« less

  20. A Multi-Mode Blade Damping Control using Shunted Piezoelectric Transducers with Active Feedback Structure

    NASA Technical Reports Server (NTRS)

    Choi, Benjamin; Morrison, Carlos; Min, James

    2009-01-01

    The Structural Dynamics and. Mechanics branch (RXS) is developing smart adaptive structures to improve fan blade damping at resonances using piezoelectric (PE) transducers. In this presentation, only one shunted PE transducer was used to demonstrate active control of multi-mode blade resonance damping on a titanium alloy (Ti-6A1-4V) flat plate model, regardless of bending, torsion, and 2-stripe modes. This work would have a significant impact on the conventional passive shunt damping world because the standard feedback control design tools can now be used to design and implement electric shunt for vibration control. In other words, the passive shunt circuit components using massive inductors and. resistors for multi-mode resonance control can be replaced with digital codes. Furthermore, this active approach with multi patches can simultaneously control several modes in the engine operating range. Dr. Benjamin Choi presented the analytical and experimental results from this work at the Propulsion-Safety and. Affordable Readiness (P-SAR) Conference in March, 2009.

  1. Evolution in performance assessment modeling as a result of regulatory review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rowat, J.H.; Dolinar, G.M.; Stephens, M.E.

    1995-12-31

    AECL is planning to build the IRUS (Intrusion Resistant Underground Structure) facility for near-surface disposal of LLRW. The PSAR (preliminary safety assessment report) was subject to an initial regulatory review during mid-1992. The regulatory authority provided comments on many aspects of the safety assessment documentation including a number of questions on specific PA (Performance Assessment) modelling assumptions. As a result of these comments as well as a separate detailed review of the IRUS disposal concept, changes were made to the conceptual and mathematical models. The original disposal concept included a non-sorbing vault backfill, with a strong reliance on the wasteformmore » as a barrier. This concept was altered to decrease reliance on the wasteform by replacing the original backfill with a sand/clinoptilolite mix, which is a better sorber of metal cations. This change lead to changes in the PA models which in turn altered the safety case for the facility. This, and other changes that impacted performance assessment modelling are the subject of this paper.« less

  2. An experimental result of estimating an application volume by machine learning techniques.

    PubMed

    Hasegawa, Tatsuhito; Koshino, Makoto; Kimura, Haruhiko

    2015-01-01

    In this study, we improved the usability of smartphones by automating a user's operations. We developed an intelligent system using machine learning techniques that periodically detects a user's context on a smartphone. We selected the Android operating system because it has the largest market share and highest flexibility of its development environment. In this paper, we describe an application that automatically adjusts application volume. Adjusting the volume can be easily forgotten because users need to push the volume buttons to alter the volume depending on the given situation. Therefore, we developed an application that automatically adjusts the volume based on learned user settings. Application volume can be set differently from ringtone volume on Android devices, and these volume settings are associated with each specific application including games. Our application records a user's location, the volume setting, the foreground application name and other such attributes as learning data, thereby estimating whether the volume should be adjusted using machine learning techniques via Weka.

  3. Upgrading of Sergiev Posad department of Moscow NPO Radon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debieve, Pierre; Delecaut, Gregory; Vanleeuw, Daniel

    Available in abstract form only. Full text of publication follows: BELGATOM and IRE Consortium has been awarded by the European Commission end of 2005 to conduct a project entitled 'Upgrading of Sergiev Posad Department of Moscow NPO Radon and the assessment of the radiological impact in the area nearby'. The main aims to achieve in the frame of this Europe-aid Project are: - Improvement of the performance and the safety level of the present radwaste management system, taking into account the additional waste expected from the Kurchatov Institute rehabilitation and from the forecast decommissioning of Research Reactors on the territorymore » of Moscow. - Basic design and assistance for the procurement of upgrading equipment related to: - radwaste sorting and pretreatment - replacement of the hydraulic system of the existing super-compactor - characterisation system for radwaste 'Support for preparing the PSAR and PEIAR for new licensing' Assessment of the radiological impact in an area of 50 km radius around Sergiev Posad Department. - The initial duration of this Project is 3 years, starting beginning of 2006. This paper describes the difficulties encountered to start and implement the Project and its status at the half of the planned time schedule. (authors)« less

  4. 40 CFR 89.210 - Maintenance of records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... limits (FEL); (3) Power rating for each configuration tested; (4) Projected applicable production/sales volume for the model year; and (5) Actual applicable production/sales volume for the model year. (c) Any... actual quarterly and cumulative applicable production/sales volume; (3) The values required to calculate...

  5. 78 FR 9281 - Regulation of Fuels and Fuel Additives: 2013 Renewable Fuel Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-07

    ...Under section 211(o) of the Clean Air Act, the Environmental Protection Agency is required to set the renewable fuel standards each November for the following year. In general the standards are designed to ensure that the applicable volumes of renewable fuel specified in the statute are used. However, the statute specifies that EPA is to project the volume of cellulosic biofuel production for the upcoming year and must base the cellulosic biofuel standard on that projected volume if it is less than the applicable volume set forth in the Act. EPA is today proposing a projected cellulosic biofuel volume for 2013 that is below the applicable volume specified in the Act. EPA is proposing that the applicable volumes of advanced biofuel and total renewable fuel would remain at the statutory levels for 2013. Finally, today's action also proposes annual percentage standards for cellulosic biofuel, biomass-based diesel, advanced biofuel, and renewable fuels that would apply to all gasoline and diesel produced or imported in year 2013.

  6. Varying termiticide application rate and volume affect initial soil penetration

    Treesearch

    Christopher Peterson

    2010-01-01

    The initial soil penetration of Premise 75 and Termidor SC, containing imidacloprid and fipronil, respectively, were tested in laboratory columns of five different soils. Three combinations of application concentration and volume were used: double the recommended active ingredient concentration at one half the recommended volume (DR), the full concentration and volume...

  7. Microcomputer Applications for Health Care Professionals. Volume II. Curriculum Improvement Project. Region II.

    ERIC Educational Resources Information Center

    Bruce, Lucy

    This volume is one of three in a self-paced computer literacy course that gives allied health students a firm base of knowledge concerning computer usage in the hospital environment. It also develops skill in several applications software packages. Volume II contains materials for three one-hour courses on word processing applications, spreadsheet…

  8. Comparison of dose volume parameters evaluated using three forward planning – optimization techniques in cervical cancer brachytherapy involving two applicators

    PubMed Central

    Basu-Roy, Somapriya; Kar, Sanjay Kumar; Das, Sounik; Lahiri, Annesha

    2017-01-01

    Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and methods We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times (‘no optimization’), ‘manual dwell weight/times’, and ‘graphical’. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D2cc) rectum and rectal point etc.; D2cc, minimum, maximum, median, and average dose to sigmoid colon; D2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced. PMID:29204164

  9. Effect of spray volume on the deposition, viability and infectivity of entomopathogenic nematodes in a foliar spray on vegetables.

    PubMed

    Brusselman, Eva; Beck, Bert; Pollet, Sabien; Temmerman, Femke; Spanoghe, Pieter; Moens, Maurice; Nuyttens, David

    2012-10-01

    Spray volume can influence the amount of free water on the leaf surface and subsequently the ability of entomopathogenic nematodes (EPNs) to move. In this study, an investigation was made of the effect of spray volume (548, 730 and 1095 L ha(-1) ) on the deposition, viability and infectivity of EPNs against Galleria mellonella on savoy cabbage, cauliflower and leek. Increasing spray volume decreased nematode deposition on 7.1 cm2 leek leaf discs at a 15° angle with the spray nozzle. Although the number of living nematodes observed on leek after 240 min of exposure was not significantly different between the low-volume application (548 L ha(-1) ) and the high-volume application (1095 L ha(-1) ), a greater infectivity was obtained in the latter application. The higher number of droplets deposited on the leek discs in the high-volume application may have stimulated nematode movement. No significant effect of spray volume was observed on the relative deposition of Steinernema carpocapsae on the bottom side of cauliflower and savoy cabbage leaf discs. In spite of the low S. carpocapsae deposition on the bottom side of the savoy cabbage discs, high infectivity was obtained against G. mellonella. Using the lowest spray volume on savoy cabbage, infectivity decreased with increasing exposure time, while infectivity was not affected by exposure time when a spray volume of 730 L ha(-1) or more was used. Spray volume is an important application parameter, as it affects nematode infectivity. Future research should investigate the effect of spray volume in the field and its influence on the effect of adjuvants. Copyright © 2012 Society of Chemical Industry.

  10. 30 CFR 203.71 - How does MMS allocate a field's suspension volume between my lease and other leases on my field?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... approve relief We will not change your authorized field's royalty suspension volume determined under § 203... application We will not change your field's royalty suspension volume The assigned lease(s) may share in any... field while we are evaluating your application We will change your field's minimum suspension volume...

  11. Magnus effect: An overview of its past and future practical applications, 1850-1985, volumes 1 and 2

    NASA Astrophysics Data System (ADS)

    Borg, J.

    The report is in two volumes and is intended to present the known data and past and future applications of Magnus effect devices. (Magnus effect devices are very high lift devices which can be used in applications where airfoils are currently used.) This first volume includes the history of Magnus effect devices, theory and principles, a significant patent review, practical marine applications, formulas and experimental data, comparisons of Magnus effect and other state-of-the-art devices, identification of further testing needed, and a proposed test program. Appendices include rudder research and a literature critique. The second volume is a collection of the drawings for 39 magnus effect patents plus a critique of each patent evaluating its potential, especially for marine applications.

  12. Applications of Tethers in Space: Workshop Proceedings, Volume 1

    NASA Technical Reports Server (NTRS)

    Baracat, W. A. (Compiler)

    1986-01-01

    The complete documentation of the workshop including all addresses, panel reports, charts, and summaries are presented. This volume presents all the reports on the fundamentals of applications of tethers in space. These applications include electrodynamic interactions, transportation, gravity utilization, constellations, technology and test, and science applications.

  13. 78 FR 69527 - Proposed Collection; Comment Request for Form 5307

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ... 5307, Application for Determination for Adopters of Master or Prototype or Volume Submitter Plans... . SUPPLEMENTARY INFORMATION: Title: Application for Determination for Adopters of Master or Prototype or Volume... purpose by adopters of master or prototype or volume submitter plans. Current Actions: There are no...

  14. Automation Applications in an Advanced Air Traffic Management System : Volume 5B. DELTA Simulation Model - Programmer's Guide.

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 5 describes the DELTA Simulation Model. It includes all documentation of the DELTA (Determine Effective Levels of Task Automation) computer simulation developed by TRW for use in the Automation Applications Study. Volume 5A includes a user's m...

  15. 75 FR 61243 - Proposed Collection; Comment Request for Form 5307

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-04

    ... 5307, Application for Determination for Adopters of Master or Prototype or Volume Submitter Plans... or Prototype or Volume Submitter Plans. OMB Number: 1545-0200. Form Number: 5307. Abstract: Employers... used as an application for this purpose by adopters of master or prototype or volume submitter plans...

  16. An Example Emphasizing Mass-Volume Relationships for Problem Solving in Soils

    ERIC Educational Resources Information Center

    Heitman, J. L.; Vepraskas, M. J.

    2009-01-01

    Mass-volume relationships are a useful tool emphasized for problem solving in many geo-science and engineering applications. These relationships also have useful applications in soil science. Developing soils students' ability to utilize mass-volume relationships through schematic diagrams of soil phases (i.e., air, water, and solid) can help to…

  17. Left ventricular pressure and volume data acquisition and analysis using LabVIEW.

    PubMed

    Cassidy, S C; Teitel, D F

    1997-03-01

    To automate analysis of left ventricular pressure-volume data, we used LabVIEW to create applications that digitize and display data recorded from conductance and manometric catheters. Applications separate data into cardiac cycles, calculate parallel conductance, and calculate indices of left ventricular function, including end-systolic elastance, preload-recruitable stroke work, stroke volume, ejection fraction, stroke work, maximum and minimum derivative of ventricular pressure, heart rate, indices of relaxation, peak filling rate, and ventricular chamber stiffness. Pressure-volume loops can be graphically displayed. These analyses are exported to a text-file. These applications have simplified and automated the process of evaluating ventricular function.

  18. Evaluation of Propiconazole Application Methods for Control of Oak Wilt in Texas Live Oaks

    Treesearch

    A. Dan Wilson; D.G. Lester

    1996-01-01

    Four fungicide application methods using the microencapsulated (blue) 14.3% EC formulation of propiconazole (Alamo), including a low-concentration high volume method, two high-concentration low volume microinjection methods, and a low-concentration intermediate volume soil drench method, were tested for effectiveness in controlling oak wilt in a mature natural stand of...

  19. Microcomputer Applications for Health Care Professionals. Volume I. Curriculum Improvement Project. Region II.

    ERIC Educational Resources Information Center

    Bruce, Lucy

    This volume is one of three in a self-paced computer literacy course that gives allied health students a firm base of knowledge concerning computer usage in the hospital environment. It also develops skill in several applications software packages. Volume I contains materials for a three-hour course. A student course syllabus provides this…

  20. 17 CFR 240.6a-1 - Application for registration as a national securities exchange or exemption from registration...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... as a national securities exchange or exemption from registration based on limited volume. 240.6a-1... national securities exchange or exemption from registration based on limited volume. (a) An application for registration as a national securities exchange, or for exemption from such registration based on limited volume...

  1. 17 CFR 240.6a-1 - Application for registration as a national securities exchange or exemption from registration...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... as a national securities exchange or exemption from registration based on limited volume. 240.6a-1... national securities exchange or exemption from registration based on limited volume. (a) An application for registration as a national securities exchange, or for exemption from such registration based on limited volume...

  2. A proposed application programming interface for a physical volume repository

    NASA Technical Reports Server (NTRS)

    Jones, Merritt; Williams, Joel; Wrenn, Richard

    1996-01-01

    The IEEE Storage System Standards Working Group (SSSWG) has developed the Reference Model for Open Storage Systems Interconnection, Mass Storage System Reference Model Version 5. This document, provides the framework for a series of standards for application and user interfaces to open storage systems. More recently, the SSSWG has been developing Application Programming Interfaces (APIs) for the individual components defined by the model. The API for the Physical Volume Repository is the most fully developed, but work is being done on APIs for the Physical Volume Library and for the Mover also. The SSSWG meets every other month, and meetings are open to all interested parties. The Physical Volume Repository (PVR) is responsible for managing the storage of removable media cartridges and for mounting and dismounting these cartridges onto drives. This document describes a model which defines a Physical Volume Repository, and gives a brief summary of the Application Programming Interface (API) which the IEEE Storage Systems Standards Working Group (SSSWG) is proposing as the standard interface for the PVR.

  3. Application of volume rendering technique (VRT) for musculoskeletal imaging.

    PubMed

    Darecki, Rafał

    2002-10-30

    A review of the applications of volume rendering technique in musculoskeletal three-dimensional imaging from CT data. General features, potential and indications for applying the method are presented.

  4. Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.

    PubMed

    Clasen, Stephan; Schmidt, Diethard; Boss, Andreas; Dietz, Klaus; Kröber, Stefan M; Claussen, Claus D; Pereira, Philippe L

    2006-03-01

    To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were placed in a triangular array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted, and the goodness of fit was assessed by using r(2). Coagulation volume, short-axis diameter, and ablation time were dependent on power output and applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter, 8.4 cm; ablation time, 193 min) was induced with a power output of 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, short-axis diameter, and ablation time were 66 cm(3), 4.5 cm, and 19 min, respectively; at 3 cm (100 W), 90 cm(3), 5.2 cm, and 22 min, respectively; at 4 cm (100 W), 132 cm(3), 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm(3), 4.2 cm, and 9 min, respectively; at 3 cm (125 W), 73 cm(3), 4.9 cm, and 12 min, respectively; and at 4 cm (125 W), 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 cm (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation, and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation. Copyright RSNA, 2006.

  5. Application Level Protocol Development for Library and Information Science Applications. Volume 1: Service Definition. Volume 2: Protocol Specification. Report No. TG.1.5; TG.50.

    ERIC Educational Resources Information Center

    Aagaard, James S.; And Others

    This two-volume document specifies a protocol that was developed using the Reference Model for Open Systems Interconnection (OSI), which provides a framework for communications within a heterogeneous network environment. The protocol implements the features necessary for bibliographic searching, record maintenance, and mail transfer between…

  6. Planning for Downtown Circulation Systems. Volume 3. Appendices.

    DOT National Transportation Integrated Search

    1983-10-01

    This volume contains worksheets for estimating circulator patronage, costs, revenues and travel impacts, detailed discussions of estimation and application procedures for the demand models developed, and a case study of the models' application using ...

  7. Market projections of cellulose nanomaterial-enabled products- Part 1: Applications

    Treesearch

    Jo Anne Shatkin; Theodore H. Wegner; E.M. (Ted) Bilek; John Cowie

    2014-01-01

    Nanocellulose provides a new materials platform for the sustainable production of high-performance nano-enabled products in an array of applications. In this paper, potential applications for cellulose nanomaterials are identified as the first step toward estimating market volume. The overall study, presented in two parts, estimates market volume on the basis of...

  8. Long-term safety assessment of trench-type surface repository at Chernobyl, Ukraine - computer model and comparison with results from simplified models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haverkamp, B.; Krone, J.; Shybetskyi, I.

    2013-07-01

    The Radioactive Waste Disposal Facility (RWDF) Buryakovka was constructed in 1986 as part of the intervention measures after the accident at Chernobyl NPP (ChNPP). Today, the surface repository for solid low and intermediate level waste (LILW) is still being operated but its maximum capacity is nearly reached. Long-existing plans for increasing the capacity of the facility shall be implemented in the framework of the European Commission INSC Programme (Instrument for Nuclear Safety Co-operation). Within the first phase of this project, DBE Technology GmbH prepared a safety analysis report of the facility in its current state (SAR) and a preliminary safetymore » analysis report (PSAR) for a future extended facility based on the planned enlargement. In addition to a detailed mathematical model, also simplified models have been developed to verify results of the former one and enhance confidence in the results. Comparison of the results show that - depending on the boundary conditions - simplifications like modeling the multi trench repository as one generic trench might have very limited influence on the overall results compared to the general uncertainties associated with respective long-term calculations. In addition to their value in regard to verification of more complex models which is important to increase confidence in the overall results, such simplified models can also offer the possibility to carry out time consuming calculations like probabilistic calculations or detailed sensitivity analysis in an economic manner. (authors)« less

  9. Manipulating biological agents and cells in micro-scale volumes for applications in medicine

    PubMed Central

    Tasoglu, Savas; Gurkan, Umut Atakan; Wang, ShuQi

    2013-01-01

    Recent technological advances provide new tools to manipulate cells and biological agents in micro/nano-liter volumes. With precise control over small volumes, the cell microenvironment and other biological agents can be bioengineered; interactions between cells and external stimuli can be monitored; and the fundamental mechanisms such as cancer metastasis and stem cell differentiation can be elucidated. Technological advances based on the principles of electrical, magnetic, chemical, optical, acoustic, and mechanical forces lead to novel applications in point-of-care diagnostics, regenerative medicine, in vitro drug testing, cryopreservation, and cell isolation/purification. In this review, we first focus on the underlying mechanisms of emerging examples for cell manipulation in small volumes targeting applications such as tissue engineering. Then, we illustrate how these mechanisms impact the aforementioned biomedical applications, discuss the associated challenges, and provide perspectives for further development. PMID:23575660

  10. In-Swath Spray Deposition Characteristics of a Low Drift Nozzle for Low Volume Aerial Application - Preliminary Results.

    USDA-ARS?s Scientific Manuscript database

    CP flat-fan nozzles with selectable tips were evaluated for droplet spectra and coverage using water sensitive papers placed in the spray swath. This study used low application volumes (1, 2, and 3 GPA) at a certain spray application height as measured precisely by laser mounted in the aircraft. No...

  11. A low-volume cavity ring-down spectrometer for sample-limited applications

    NASA Astrophysics Data System (ADS)

    Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.

    2014-08-01

    In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.

  12. Revised congressional budget request, FY 1982. Conservation and renewable energy program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-03-01

    Programs dealing with conservation and renewable energy are reprinted from the Revised Congressional Budget Request FY 1982. From Volume 7, Energy Conservation, information is presented on: buildings and community systems; industrial programs; transportation programs; state and local programs; inventor's program energy conversion technology; energy impact assistance; and residential/commercial retrofit. From Volume 2, Energy Supply Research and Development, information and data are presented on: solar building applications; solar industrial applications; solar power applications; solar information systems; SERI facility; solar international activities; alcohol fuels; geothermal; and hydropower. From Volume 6, Energy Production, Demonstration, and Distribution, information and data on solar energy production,more » demonstration, and distribution are presented. From Volume 3, Energy Supply and R and D Appropriation, information and data on electric energy systems and energy storage systems are included. From Volume 4, information and data are included on geothermal resources development fund. In Volume 5, Power Marketing Administrations, information and data are presented on estimates by appropriations, positions and staff years by appropriation, staffing distribution, and power marketing administrations. Recissions and deferrals for FY 1981 are given. (MCW)« less

  13. Department of Defense Acquisition of Vaccine Production. Volume 1

    DTIC Science & Technology

    2000-12-01

    and by Science Applications International Corporation (SAIC) under a contract with the Office of the Director, Defense Research and Engineering...development clinical trials, manufacturing, and development; requires application of state-of- testing the-art research capability to problem solving...trials, vaccine recommending usage manufacturing scale, and logistics bodies (e.g., AFEB, ACIP) License application Prepare and submit -100 volume

  14. Low volume undiluted Btk application against heavy gypsy moth population densities in southern Corsica

    Treesearch

    Robert A. Fusco; Jean-Claude Martin

    2003-01-01

    Low volume undiluted applications of Bacillus thuringiensis are common and efficacious against coniferous forest pests such as pine processionary moth and spruce budworm, but have not been common practice against deciduous forest pests due to coverage issues.

  15. Mental Health Manpower, Volume I: An Annotated Bibliography and Commentary, and Volume II: Recruitment, Training and Utilization - A Compilation of Articles, Surveys, and a Review of Applicable Literature.

    ERIC Educational Resources Information Center

    Klutch, Murray

    The study was designed to provide a base for mental health manpower planning. The first and principal section of Volume I is an annotated bibliography of applicable articles and books. An index lists items included in the bibliography according to subject and profession. A discussion of two conceptual approaches to alleviating the manpower…

  16. Extending the imaging volume for biometric iris recognition.

    PubMed

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  17. Field evaluation of a self-propelled sprayer and effects of the application rate on spray deposition and losses to the ground in greenhouse tomato crops.

    PubMed

    Sánchez-Hermosilla, Julián; Rincón, Víctor J; Páez, Francisco; Agüera, Francisco; Carvajal, Fernando

    2011-08-01

    In the greenhouses of south-eastern Spain, plant protection products are applied using mainly sprayers at high pressures and high volumes. This results in major losses on the ground and less than uniform spray deposition on the canopy. Recently, self-propelled vehicles equipped with vertical spray booms have appeared on the market. In this study, deposition on the canopy and the losses to the ground at different spray volumes have been compared, using a self-propelled vehicle with vertical spray booms versus a gun sprayer. Three different spray volumes have been tested with a boom sprayer, and two with a spray gun. The vehicle with the vertical spray boom gave similar depositions to those made with the gun, but at lower application volumes. Also, the distribution of the vertical spray boom was more uniform, with lower losses to the ground. The vertical spray booms used in tomato crops improve the application of plant protection products with respect to the spray gun, reducing the application volumes and the environmental risks of soil pollution. Copyright © 2011 Society of Chemical Industry.

  18. VOLUMNECT: measuring volumes with Kinect

    NASA Astrophysics Data System (ADS)

    Quintino Ferreira, Beatriz; Griné, Miguel; Gameiro, Duarte; Costeira, João. Paulo; Sousa Santos, Beatriz

    2014-03-01

    This article presents a solution to volume measurement object packing using 3D cameras (such as the Microsoft KinectTM). We target application scenarios, such as warehouses or distribution and logistics companies, where it is important to promptly compute package volumes, yet high accuracy is not pivotal. Our application auto- matically detects cuboid objects using the depth camera data and computes their volume and sorting it allowing space optimization. The proposed methodology applies to a point cloud simple computer vision and image processing methods, as connected components, morphological operations and Harris corner detector, producing encouraging results, namely an accuracy in volume measurement of 8mm. Aspects that can be further improved are identified; nevertheless, the current solution is already promising turning out to be cost effective for the envisaged scenarios.

  19. Annealing Reduces Free Volumes In Thermoplastics

    NASA Technical Reports Server (NTRS)

    Singh, Jag J.; St. Clair, Terry L.

    1988-01-01

    Investigation conducted to determine free volumes and water-absorption characteristics of two types of thermoplastic polymide as functions of annealing histories. Reductions reach asymptotic values after several annealing cycles. High-temperature thermoplastics excellent candidates for use in aerospace applications. Graphite-fiber composites containing thermoplastic matrices have wide applicability.

  20. 40 CFR 89.202 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emission credits among engine families within a given manufacturer's product line. Banking means the... credits” refer to emission credits based on the projected applicable production/sales volume of the engine... applicable production/sales volume as contained in the end-of-year reports submitted to EPA. Some or all of...

  1. Application site and mosquito age influences malathion- and permethrin-induced mortality in Culex quinquefasciatus

    USDA-ARS?s Scientific Manuscript database

    Concentrations of malathion and permethrin typical in droplets generated from ultra-low volume and low volume applications were evaluated for efficacy against multiple-aged Culex quinquefasciatus Say, using a topical bioassay. Although during mosquito control operations insecticide droplets will imp...

  2. Impact of application site on the efficacy of two topically-applied insecticides to Culex quinquefasciatus Say

    USDA-ARS?s Scientific Manuscript database

    Ultra-low volume and low volume insecticide treatments commonly used to control mosquito populations were evaluated for efficacy against Culex quinquefasciatus using a topical bioassay technique. Traditional topical bioassays focus pesticide application to the mesothoracic pleural area. Although, in...

  3. Impact of topical application site efficacy of permethrin and malathion on Culex quinquefasciatus

    USDA-ARS?s Scientific Manuscript database

    Concentrations of permethrin and malathion found in droplets generated from ultra-low volume and low volume sprays used to control adult mosquito populations were evaluated for efficacy against Culex quinquefasciatus Say using a topical application bioassay. Although insecticide droplets will imping...

  4. Quality of Life. Volume II: Application to Persons with Disabilities.

    ERIC Educational Resources Information Center

    Schalock, Robert L., Ed.; Siperstein, Gary N., Ed.

    This volume summarizes current policies and programmatic practices that are influencing the quality of life of persons with mental retardation and developmental disabilities. Part 1, "Service Delivery Application," contains: "Using Person-Centered Planning To Address Personal Quality of Life" (John Butterworth and others); "The Aftermath of…

  5. Impact of acetic acid concentration, application volume, and adjuvants on weed control efficacy

    USDA-ARS?s Scientific Manuscript database

    Vinegar has been identified as a potential organic herbicide, yet additional information is needed to determine the influence of acetic acid concentration, application volume, and adjuvants on weed control. Acetic acid is a contact herbicide, injuring and killing plants by first destroying the cell ...

  6. Vehicle-to-infrastructure (V2I) safety applications performance requirements, vol. 3, red light violation warning (RLVW).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the third of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume d...

  7. Vehicle-to-infrastructure (V2I) safety applications : performance requirements, vol. 7, stop sign gap assist (SSGA).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the seventh of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume...

  8. Vehicle-to-infrastructure (V2I) safety applications performance requirements, vol. 2, curve speed warning (CSW).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the second of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume ...

  9. Influence of liquid-volume and airflow rates on spray application quality and homogeneity in super-intensive olive tree canopies.

    PubMed

    Miranda-Fuentes, Antonio; Rodríguez-Lizana, Antonio; Gil, Emilio; Agüera-Vega, J; Gil-Ribes, Jesús A

    2015-12-15

    Olive is a key crop in Europe, especially in countries around the Mediterranean Basin. Optimising the parameters of a spray is essential for sustainable pesticide use, especially in high-input systems, such as the super-intensive hedgerow system. Parameters may be optimised by adjusting the applied volume and airflow rate of sprays, in addition to the liquid to air proportion and the relationship between air velocity and airflow rate. Two spray experiments using a commercial airblast sprayer were conducted in a super-intensive orchard to study how varying the liquid volume rate (testing volumes of 182, 619, and 1603 l ha(-1)) and volumetric airflow rate (with flow rates of 11.93, 8.90, and 6.15 m(3) s(-1)) influences the coverage parameters and the amount and distribution of deposits in different zones of the canopy.. Our results showed that an increase in the application volume raised the mean deposit and percentage coverage, but decreased the application efficiency, spray penetration, and deposit homogeneity. Furthermore, we found that the volumetric airflow rate had a lower influence on the studied parameters than the liquid volume; however, an increase in the airflow rate improved the application efficiency and homogeneity to a certain threshold, after which the spray quality decreased. This decrease was observed in the high-flow treatment. Our results demonstrate that intermediate liquid volume rates and volumetric airflow rates are required for the optimal spraying of pesticides on super-intensive olive crops, and would reduce current pollution levels. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Enhancing radiological volumes with symbolic anatomy using image fusion and collaborative virtual reality.

    PubMed

    Silverstein, Jonathan C; Dech, Fred; Kouchoukos, Philip L

    2004-01-01

    Radiological volumes are typically reviewed by surgeons using cross-sections and iso-surface reconstructions. Applications that combine collaborative stereo volume visualization with symbolic anatomic information and data fusions would expand surgeons' capabilities in interpretation of data and in planning treatment. Such an application has not been seen clinically. We are developing methods to systematically combine symbolic anatomy (term hierarchies and iso-surface atlases) with patient data using data fusion. We describe our progress toward integrating these methods into our collaborative virtual reality application. The fully combined application will be a feature-rich stereo collaborative volume visualization environment for use by surgeons in which DICOM datasets will self-report underlying anatomy with visual feedback. Using hierarchical navigation of SNOMED-CT anatomic terms integrated with our existing Tele-immersive DICOM-based volumetric rendering application, we will display polygonal representations of anatomic systems on the fly from menus that query a database. The methods and tools involved in this application development are SNOMED-CT, DICOM, VISIBLE HUMAN, volumetric fusion and C++ on a Tele-immersive platform. This application will allow us to identify structures and display polygonal representations from atlas data overlaid with the volume rendering. First, atlas data is automatically translated, rotated, and scaled to the patient data during loading using a public domain volumetric fusion algorithm. This generates a modified symbolic representation of the underlying canonical anatomy. Then, through the use of collision detection or intersection testing of various transparent polygonal representations, the polygonal structures are highlighted into the volumetric representation while the SNOMED names are displayed. Thus, structural names and polygonal models are associated with the visualized DICOM data. This novel juxtaposition of information promises to expand surgeons' abilities to interpret images and plan treatment.

  11. Impacts of Outer Continental Shelf (OCS) development on recreation and tourism. Volume 2. Final report and case studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The final report for the project is comprised of five volumes. The volume presents the study conclusions, summarizes the methodology used (more detail is found in Volume 3), discusses four case study applications of the model, and contains profiles of coastal communities in an Appendix.

  12. Snow and Ice Control Materials for Texas Roads; VOLUME 1: Literature and Best Practices Review; VOLUME 2: Field Trials and Laboratory Study

    DOT National Transportation Integrated Search

    2017-03-01

    This report provides findings from a four-year research study of snow and ice control materials for winter weather roadway maintenance applications in Texas. The report is presented in two volumes. Volume 1 is a literature review and best practices r...

  13. Value of Magnetic Resonance Imaging Without or With Applicator in Place for Target Definition in Cervix Cancer Brachytherapy.

    PubMed

    Pötter, Richard; Federico, Mario; Sturdza, Alina; Fotina, Irina; Hegazy, Neamat; Schmid, Maximilian; Kirisits, Christian; Nesvacil, Nicole

    2016-03-01

    To define, in the setting of cervical cancer, to what extent information from additional pretreatment magnetic resonance imaging (MRI) without the brachytherapy applicator improves conformity of CT-based high-risk clinical target volume (CTVHR) contours, compared with the MRI for various tumor stages (International Federation of Gynecology and Obstetrics [FIGO] stages I-IVA). The CTVHR was contoured in 39 patients with cervical cancer (FIGO stages I-IVA) (1) on CT images based on clinical information (CTVHR-CTClinical) alone; and (2) using an additional MRI before brachytherapy, without the applicator (CTVHR-CTpre-BT MRI). The CT contours were compared with reference contours on MRI with the applicator in place (CTVHR-MRIref). Width, height, thickness, volumes, and topography were analyzed. The CT-MRIref differences hardly varied in stage I tumors (n=8). In limited-volume stage IIB and IIIB tumors (n=19), CTVHR-CTpre-BT MRI-MRIref volume differences (2.6 cm(3) [IIB], 7.3 cm(3) [IIIB]) were superior to CTVHR-CTClinical-MRIref (11.8 cm(3) [IIB], 22.9 cm(3) [IIIB]), owing to significant improvement of height and width (P<.05). In advanced disease (n=12), improved agreement with MR volume, width, and height was achieved for CTVHR-CTpre-BT MRI. In 5 of 12 cases, MRIref contours were partly missed on CT. Pre-BT MRI helps to define CTVHR before BT implantation appropriately, if only CT images with the applicator in place are available for BT planning. Significant improvement is achievable in limited-volume stage IIB and IIIB tumors. In more advanced disease (extensive IIB to IVA), improvement of conformity is possible but may be associated with geographic misses. Limited impact on precision of CTVHR-CT is expected in stage IB tumors. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. PROCEEDINGS: EIGHTH SYMPOSIUM ON THE TRANSFER AND UTILIZATION OF PARTICULATE CONTROL TECHNOLOGY - VOLUME 2. BAGHOUSES AND PARTICULATE CONTROL FOR NEW APPLICATIONS

    EPA Science Inventory

    The two-volume proceedings describe the latest research and development efforts to improve particulate control devices, while treating traditional concerns of operational cost and compliance. Overall, particulate control remains a key issue in the cost and applicability of furnac...

  15. Integrated remote sensing and visualization (IRSV) system for transportation infrastructure operations and management, phase one, volume 3 : use of scanning LiDAR in structural evaluation of bridges.

    DOT National Transportation Integrated Search

    2009-12-01

    This volume introduces several applications of remote bridge inspection technologies studied in : this Integrated Remote Sensing and Visualization (IRSV) study using ground-based LiDAR : systems. In particular, the application of terrestrial LiDAR fo...

  16. Vehicle-to-infrastructure (V2I) safety applications performance requirements, vol. 5, spot weather information warning – reduced speed (SWIW-RS).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the fifth of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume d...

  17. Vehicle-to-infrastructure (V2I) safety applications performance requirements, vol. 6, spot weather information warning – diversion (SWIW-D).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the sixth of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume d...

  18. Vehicle-to-infrastructure (V2I) safety applications performance requirements, vol. 4, reduced speed zone warning with lane closure (RSZW/LC).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the fourth of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume ...

  19. 40 CFR 80.1622 - Approval for small refiner and small volume refinery status.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... appropriate data to correct the record when the company submits its application. (ii) Foreign small refiners... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Approval for small refiner and small... Approval for small refiner and small volume refinery status. (a) Applications for small refiner or small...

  20. The application of volume-outcome contouring in data warehousing.

    PubMed

    Studnicki, James; Berndt, Donald J; Luther, Stephen L; Fisher, John W

    2004-01-01

    Despite a compelling body of published research on the nature of provider volume and clinical outcomes, healthcare executives and policymakers have not managed to develop and implement systems that are useful in directing patients to higher volume providers via selective referral or avoidance. A specialized data warehouse application, utilizing hospital discharge data linked to physician biographical information, allows detailed analysis of physician and hospital volume and the resulting pattern (contour) of related outcomes such as mortality, complications, and medical errors. The approach utilizes a historical repository of hospital discharge data in which the outcomes of interest, important patient characteristics and risk factors used in severity-adjusting of the outcomes are derived from the coding structure of the data.

  1. Optimization of antitumor treatment conditions for transcutaneous CO2 application: An in vivo study.

    PubMed

    Ueha, Takeshi; Kawamoto, Teruya; Onishi, Yasuo; Harada, Risa; Minoda, Masaya; Toda, Mitsunori; Hara, Hitomi; Fukase, Naomasa; Kurosaka, Masahiro; Kuroda, Ryosuke; Akisue, Toshihiro; Sakai, Yoshitada

    2017-06-01

    Carbon dioxide (CO2) therapy can be applied to treat a variety of disorders. We previously found that transcutaneous application of CO2 with a hydrogel decreased the tumor volume of several types of tumors and induced apoptosis via the mitochondrial pathway. However, only one condition of treatment intensity has been tested. For widespread application in clinical antitumor therapy, the conditions must be optimized. In the present study, we investigated the relationship between the duration, frequency, and treatment interval of transcutaneous CO2 application and antitumor effects in murine xenograft models. Murine xenograft models of three types of human tumors (breast cancer, osteosarcoma, and malignant fibrous histiocytoma/undifferentiated pleomorphic sarcoma) were used to assess the antitumor effects of transcutaneous CO2 application of varying durations, frequencies, and treatment intervals. In all human tumor xenografts, apoptosis was significantly induced by CO2 treatment for ≥10 min, and a significant decrease in tumor volume was observed with CO2 treatments of >5 min. The effect on tumor volume was not dependent on the frequency of CO2 application, i.e., twice or five times per week. However, treatment using 3- and 4-day intervals was more effective at decreasing tumor volume than treatment using 2- and 5-day intervals. The optimal conditions of transcutaneous CO2 application to obtain the best antitumor effect in various tumors were as follows: greater than 10 min per application, twice per week, with 3- and 4-day intervals, and application to the site of the tumor. The results suggest that this novel transcutaneous CO2 application might be useful to treat primary tumors, while mitigating some side effects, and therefore could be safe for clinical trials.

  2. Combining transrectal ultrasound and CT for image-guided adaptive brachytherapy of cervical cancer: Proof of concept.

    PubMed

    Nesvacil, Nicole; Schmid, Maximilian P; Pötter, Richard; Kronreif, Gernot; Kirisits, Christian

    To investigate the feasibility of a treatment planning workflow for three-dimensional image-guided cervix cancer brachytherapy, combining volumetric transrectal ultrasound (TRUS) for target definition with CT for dose optimization to organs at risk (OARs), for settings with no access to MRI. A workflow for TRUS/CT-based volumetric treatment planning was developed, based on a customized system including ultrasound probe, stepper unit, and software for image volume acquisition. A full TRUS/CT-based workflow was simulated in a clinical case and compared with MR- or CT-only delineation. High-risk clinical target volume was delineated on TRUS, and OARs were delineated on CT. Manually defined tandem/ring applicator positions on TRUS and CT were used as a reference for rigid registration of the image volumes. Treatment plan optimization for TRUS target and CT organ volumes was performed and compared to MRI and CT target contours. TRUS/CT-based contouring, applicator reconstruction, image fusion, and treatment planning were feasible, and the full workflow could be successfully demonstrated. The TRUS/CT plan fulfilled all clinical planning aims. Dose-volume histogram evaluation of the TRUS/CT-optimized plan (high-risk clinical target volume D 90 , OARs D 2cm³ for) on different image modalities showed good agreement between dose values reported for TRUS/CT and MRI-only reference contours and large deviations for CT-only target parameters. A TRUS/CT-based workflow for full three-dimensional image-guided cervix brachytherapy treatment planning seems feasible and may be clinically comparable to MRI-based treatment planning. Further development to solve challenges with applicator definition in the TRUS volume is required before systematic applicability of this workflow. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Prototypic Development and Evaluation of a Medium Format Metric Camera

    NASA Astrophysics Data System (ADS)

    Hastedt, H.; Rofallski, R.; Luhmann, T.; Rosenbauer, R.; Ochsner, D.; Rieke-Zapp, D.

    2018-05-01

    Engineering applications require high-precision 3D measurement techniques for object sizes that vary between small volumes (2-3 m in each direction) and large volumes (around 20 x 20 x 1-10 m). The requested precision in object space (1σ RMS) is defined to be within 0.1-0.2 mm for large volumes and less than 0.01 mm for small volumes. In particular, focussing large volume applications the availability of a metric camera would have different advantages for several reasons: 1) high-quality optical components and stabilisations allow for a stable interior geometry of the camera itself, 2) a stable geometry leads to a stable interior orientation that enables for an a priori camera calibration, 3) a higher resulting precision can be expected. With this article the development and accuracy evaluation of a new metric camera, the ALPA 12 FPS add|metric will be presented. Its general accuracy potential is tested against calibrated lengths in a small volume test environment based on the German Guideline VDI/VDE 2634.1 (2002). Maximum length measurement errors of less than 0.025 mm are achieved with different scenarios having been tested. The accuracy potential for large volumes is estimated within a feasibility study on the application of photogrammetric measurements for the deformation estimation on a large wooden shipwreck in the German Maritime Museum. An accuracy of 0.2 mm-0.4 mm is reached for a length of 28 m (given by a distance from a lasertracker network measurement). All analyses have proven high stabilities of the interior orientation of the camera and indicate the applicability for a priori camera calibration for subsequent 3D measurements.

  4. A review of multifunctional structure technology for aerospace applications

    NASA Astrophysics Data System (ADS)

    Sairajan, K. K.; Aglietti, G. S.; Mani, K. M.

    2016-03-01

    The emerging field of multifunctional structure (MFS) technologies enables the design of systems with reduced mass and volume, thereby improving their overall efficiency. It requires developments in different engineering disciplines and their integration into a single system without degrading their individual performances. MFS is particularly suitable for aerospace applications where mass and volume are critical to the cost of the mission. This article reviews the current state of the art of multifunctional structure technologies relevant to aerospace applications.

  5. Variable volume combustor with a conical liner support

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Thomas Edward; McConnaughhay, Johnie Franklin; Keener, Chrisophter Paul

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a conical liner support supporting the liner.

  6. Determination of gas volume trapped in a closed fluid system

    NASA Technical Reports Server (NTRS)

    Hunter, W. F.; Jolley, J. E.

    1971-01-01

    Technique involves extracting known volume of fluid and measuring system before and after extraction, volume of entrapped gas is then computed. Formula derived from ideal gas laws is basis of this method. Technique is applicable to thermodynamic cycles and hydraulic systems.

  7. 76 FR 20721 - Notice of Permit Applications Received Under the Antarctic Conservation Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... Conservation Act AGENCY: National Science Foundation. ACTION: Notice of permit applications received under the... Diego. The volume of the air sacs and lungs are critical to the diving physiology of penguins in at... total body O 2 stores in various species. And second, the ratio of air sac to lung volume is a potential...

  8. 30 CFR 253.13 - How much OSFR must I demonstrate?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: COF worst case oil-spill discharge volume Applicable amount of OSFR Over 1,000 bbls but not more than... must demonstrate OSFR in accordance with the following table: COF worst case oil-spill discharge volume... applicable table in paragraph (b)(1) or (b)(2) for a facility with a potential worst case oil-spill discharge...

  9. Sensors, Volume 4, Thermal Sensors

    NASA Astrophysics Data System (ADS)

    Scholz, Jorg; Ricolfi, Teresio

    1996-12-01

    'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This volume describes the construction and applicational aspects of thermal sensors while presenting a rigorous treatment of the underlying physical principles. It provides a unique overview of the various categories of sensors as well as of specific groups, e.g. temperature sensors (resistance thermometers, thermocouples, and radiation thermometers), noise and acoustic thermometers, heat-flow and mass-flow sensors. Specific facettes of applications are presented by specialists from different fields including process control, automotive technology and cryogenics. This volume is an indispensable reference work and text book for both specialists and newcomers, researchers and developers.

  10. Integrating segmentation methods from the Insight Toolkit into a visualization application.

    PubMed

    Martin, Ken; Ibáñez, Luis; Avila, Lisa; Barré, Sébastien; Kaspersen, Jon H

    2005-12-01

    The Insight Toolkit (ITK) initiative from the National Library of Medicine has provided a suite of state-of-the-art segmentation and registration algorithms ideally suited to volume visualization and analysis. A volume visualization application that effectively utilizes these algorithms provides many benefits: it allows access to ITK functionality for non-programmers, it creates a vehicle for sharing and comparing segmentation techniques, and it serves as a visual debugger for algorithm developers. This paper describes the integration of image processing functionalities provided by the ITK into VolView, a visualization application for high performance volume rendering. A free version of this visualization application is publicly available and is available in the online version of this paper. The process for developing ITK plugins for VolView according to the publicly available API is described in detail, and an application of ITK VolView plugins to the segmentation of Abdominal Aortic Aneurysms (AAAs) is presented. The source code of the ITK plugins is also publicly available and it is included in the online version.

  11. Packaged peristaltic micropump for controlled drug delivery application

    NASA Astrophysics Data System (ADS)

    Vinayakumar, K. B.; Nadiger, Girish; R. Shetty, Vikas; Dinesh, N. S.; Nayak, M. M.; Rajanna, K.

    2017-01-01

    Micropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from μTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application. All the micropump components were fabricated using the conventional fabrication technique. The volume flow variation of the pump has been characterized for different viscous fluids. The change in volume flow due to change in back pressure has been presented in detail. The fail-safe mode operation of the pump has been tested and leak rate was measured (˜0.14% leak for an inlet pressure of 140 kPa) for different inlet pressures. The precision volume flow of the pump has been achieved by measuring the pinch cam position and load current. The accuracy in the volume flow has been measured after 300 rotations. Finally, the complete system has been integrated with the necessary electronics and an android application has been developed for the self-administration of bolus and basal delivery of insulin.

  12. Applications of Tethers in Space, Volume 2

    NASA Technical Reports Server (NTRS)

    Cron, A. C. (Compiler)

    1985-01-01

    Topics discussed include tethered satellites, tether deployment, satellite systems, science applications, electrodynamic interactions, transportation applications, artificial gravity, constellations, and technology and testing.

  13. Frequency Domain Computer Programs for Prediction and Analysis of Rail Vehicle Dynamics : Volume 1. Technical Report

    DOT National Transportation Integrated Search

    1975-12-01

    Frequency domain computer programs developed or acquired by TSC for the analysis of rail vehicle dynamics are described in two volumes. Volume I defines the general analytical capabilities required for computer programs applicable to single rail vehi...

  14. EPA RREL'S MOBILE VOLUME REDUCTION UNIT -- APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    The volume reduction unit (VRU) is a pilot-scale, mobile soil washing system designed to remove organic contaminants from the soil through particle size separation and solubilization. The VRU removes contaminants by suspending them in a wash solution and by reducing the volume of...

  15. 40 CFR 82.176 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of an otherwise unacceptable substitute. (3) Small volume use within SNAP sectors. Within the nine principal SNAP sectors, persons introducing a substitute whose expected volume of use amounts to less than.... Notification shall include the name of the substitute, the volume used in the test marketing, intended sector...

  16. 40 CFR 82.176 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of an otherwise unacceptable substitute. (3) Small volume use within SNAP sectors. Within the nine principal SNAP sectors, persons introducing a substitute whose expected volume of use amounts to less than.... Notification shall include the name of the substitute, the volume used in the test marketing, intended sector...

  17. Estimating habitat volume of living resources using three-dimensional circulation and biogeochemical models

    NASA Astrophysics Data System (ADS)

    Smith, Katharine A.; Schlag, Zachary; North, Elizabeth W.

    2018-07-01

    Coupled three-dimensional circulation and biogeochemical models predict changes in water properties that can be used to define fish habitat, including physiologically important parameters such as temperature, salinity, and dissolved oxygen. However, methods for calculating the volume of habitat defined by the intersection of multiple water properties are not well established for coupled three-dimensional models. The objectives of this research were to examine multiple methods for calculating habitat volume from three-dimensional model predictions, select the most robust approach, and provide an example application of the technique. Three methods were assessed: the "Step," "Ruled Surface", and "Pentahedron" methods, the latter of which was developed as part of this research. Results indicate that the analytical Pentahedron method is exact, computationally efficient, and preserves continuity in water properties between adjacent grid cells. As an example application, the Pentahedron method was implemented within the Habitat Volume Model (HabVol) using output from a circulation model with an Arakawa C-grid and physiological tolerances of juvenile striped bass (Morone saxatilis). This application demonstrates that the analytical Pentahedron method can be successfully applied to calculate habitat volume using output from coupled three-dimensional circulation and biogeochemical models, and it indicates that the Pentahedron method has wide application to aquatic and marine systems for which these models exist and physiological tolerances of organisms are known.

  18. Volume dependence of N-body bound states

    NASA Astrophysics Data System (ADS)

    König, Sebastian; Lee, Dean

    2018-04-01

    We derive the finite-volume correction to the binding energy of an N-particle quantum bound state in a cubic periodic volume. Our results are applicable to bound states with arbitrary composition and total angular momentum, and in any number of spatial dimensions. The only assumptions are that the interactions have finite range. The finite-volume correction is a sum of contributions from all possible breakup channels. In the case where the separation is into two bound clusters, our result gives the leading volume dependence up to exponentially small corrections. If the separation is into three or more clusters, there is a power-law factor that is beyond the scope of this work, however our result again determines the leading exponential dependence. We also present two independent methods that use finite-volume data to determine asymptotic normalization coefficients. The coefficients are useful to determine low-energy capture reactions into weakly bound states relevant for nuclear astrophysics. Using the techniques introduced here, one can even extract the infinite-volume energy limit using data from a single-volume calculation. The derived relations are tested using several exactly solvable systems and numerical examples. We anticipate immediate applications to lattice calculations of hadronic, nuclear, and cold atomic systems.

  19. Fundamentals of electric power conversion. Volume 2, Energy-efficient polyphase AC induction motors, final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umans, S.D.

    1992-12-01

    Its rugged nature and straightforward design make the induction motor the most commonly used type of electric motor. This motor ranges in size fro the fractional-horsepower, single-phase motors found in household appliances to polyphase motors rated at thousands of horsepower for industrial applications. Volume 1 of this report describes the function of induction motors, their characteristics, and induction motor testing. Volume 2 describes the characteristics of high-efficiency induction motors, with emphasis on the techniques used to obtain high efficiency. This two-volume report is written in nontechnical language and is intended for readers who require background from applications, marketing, motor planning,more » or managerial perspective.« less

  20. Fundamentals of electric power conversion. Volume 1, Operating characteristics and testing of AC induction motors, final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umans, S.D.

    1992-12-01

    Its rugged nature and straightforward design make the induction motor the most commonly used type of electric motor. This motor ranges in size from the fractional-horsepower, single-phase motors found in household appliances to polyphase motors rated at thousands of horsepower for industrial applications. Volume 1 of this report describes the function of induction motors, their characteristics, and induction motor testing. Volume 2 describes the characteristics of high-efficiency induction motors, with emphasis on the techniques used to obtain high efficiency. This two-volume report is written in nontechnical language and is intended for readers who require background from an applications, marketing, motormore » planning, or managerial perspective.« less

  1. Three-dimensional analysis of anisotropic spatially reinforced structures

    NASA Technical Reports Server (NTRS)

    Bogdanovich, Alexander E.

    1993-01-01

    The material-adaptive three-dimensional analysis of inhomogeneous structures based on the meso-volume concept and application of deficient spline functions for displacement approximations is proposed. The general methodology is demonstrated on the example of a brick-type mosaic parallelepiped arbitrarily composed of anisotropic meso-volumes. A partition of each meso-volume into sub-elements, application of deficient spline functions for a local approximation of displacements and, finally, the use of the variational principle allows one to obtain displacements, strains, and stresses at anypoint within the structural part. All of the necessary external and internal boundary conditions (including the conditions of continuity of transverse stresses at interfaces between adjacent meso-volumes) can be satisfied with requisite accuracy by increasing the density of the sub-element mesh. The application of the methodology to textile composite materials is described. Several numerical examples for woven and braided rectangular composite plates and stiffened panels under transverse bending are considered. Some typical effects of stress concentrations due to the material inhomogeneities are demonstrated.

  2. Compound refractive X-ray lens

    DOEpatents

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  3. Proceedings of the AMEDD (Army Medical Department) Clinical Psychology Short Course: Military Applications of Neuropsychology and Health Psychology Held in Presidio of San Francisco, California on 9-13 March 1987. Volume 1

    DTIC Science & Technology

    1987-03-01

    1 ,•i \\fLL c;R: MILITARY APPLICATIONS OF CLINICAL NEUROPSYCHOLOGY AND HEALTH PSYCHOLOGY 00 ;-"~~L’ -’L--, ’• - 9-13 March 1987 .4+; Volume I...Clinical Psychology Short Course: Military Applications of Neuropsychology and Health Psychology Held in Presido -of San Franciscoj, California on 9-ý13...tApproved for public releasoo, DTIC FORM LLr3 OPI: DTIC-TID PROCEEDINGS OF THE 1987 AMEDD CLINICAL PSYCHOLOGY SHORT COURSE MILITARY APPLICATIONS OF

  4. 3D ultrasound volume stitching using phase symmetry and harris corner detection for orthopaedic applications

    NASA Astrophysics Data System (ADS)

    Dalvi, Rupin; Hacihaliloglu, Ilker; Abugharbieh, Rafeef

    2010-03-01

    Stitching of volumes obtained from three dimensional (3D) ultrasound (US) scanners improves visualization of anatomy in many clinical applications. Fast but accurate volume registration remains the key challenge in this area.We propose a volume stitching method based on efficient registration of 3D US volumes obtained from a tracked US probe. Since the volumes, after adjusting for probe motion, are coarsely registered, we obtain salient correspondence points in the central slices of these volumes. This is done by first removing artifacts in the US slices using intensity invariant local phase image processing and then applying the Harris Corner detection algorithm. Fast sub-volume registration on a small neighborhood around the points then gives fast, accurate 3D registration parameters. The method has been tested on 3D US scans of phantom and real human radius and pelvis bones and a phantom human fetus. The method has also been compared to volumetric registration, as well as feature based registration using 3D-SIFT. Quantitative results show average post-registration error of 0.33mm which is comparable to volumetric registration accuracy (0.31mm) and much better than 3D-SIFT based registration which failed to register the volumes. The proposed method was also much faster than volumetric registration (~4.5 seconds versus 83 seconds).

  5. SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, T; Diak, A; Surucu, M

    Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions inmore » artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any geometric shifts after CT to MRI registration based on anatomical landmarks.« less

  6. Plexcitonics: Coupled and Plasmon-Exciton Systems with Tailorable Properties

    DTIC Science & Technology

    2013-11-14

    demonstrated efficient steam generation from aqueous nanoparticles solutions without heating the bulk volume of the liquid. Application in ethanol ...solutions without heating the bulk volume of the liquid. Applications in ethanol distillation and sanitation have been demonstrated. Key Accomplishments...nanoparticle surface. This state-selective population of adsorbate resonances could be exploited to prepare reactants in specific states on nanoparticle

  7. Evaluation of ultra low volume and thermal fog pesticide applications against Old World Phlebotomine sand fly vectors of Leishmania in Kenya

    USDA-ARS?s Scientific Manuscript database

    One component of the Department of Defense (DoD) pest management system is ultra-low volume (ULV) and/or thermal fog aerosol pesticide application. Despite widespread implementations of this and other components of the system, such as use of repellents and permethrin, US military operations in hot-a...

  8. Demonstrating the Gas Laws.

    ERIC Educational Resources Information Center

    Holko, David A.

    1982-01-01

    Presents a complete computer program demonstrating the relationship between volume/pressure for Boyle's Law, volume/temperature for Charles' Law, and volume/moles of gas for Avagadro's Law. The programing reinforces students' application of gas laws and equates a simulated moving piston to theoretical values derived using the ideal gas law.…

  9. Variable volume combustor

    DOEpatents

    Ostebee, Heath Michael; Ziminsky, Willy Steve; Johnson, Thomas Edward; Keener, Christopher Paul

    2017-01-17

    The present application provides a variable volume combustor for use with a gas turbine engine. The variable volume combustor may include a liner, a number of micro-mixer fuel nozzles positioned within the liner, and a linear actuator so as to maneuver the micro-mixer fuel nozzles axially along the liner.

  10. Application of Hydrogel in Reconstruction Surgery: Hydrogel/Fat Graft Complex Filler for Volume Reconstruction in Critical Sized Muscle Defects.

    PubMed

    Lui, Y F; Ip, W Y

    2016-01-01

    Autogenic fat graft usually suffers from degeneration and volume shrinkage in volume reconstruction applications. How to maintain graft viability and graft volume is an essential consideration in reconstruction therapies. In this presented investigation, a new fat graft transplantation method was developed aiming to improve long term graft viability and volume reconstruction effect by incorporation of hydrogel. The harvested fat graft is dissociated into small fragments and incorporated into a collagen based hydrogel to form a hydrogel/fat graft complex for volume reconstruction purpose. In vitro results indicate that the collagen based hydrogel can significantly improve the survivability of cells inside isolated graft. In a 6-month investigation on artificial created defect model, this hydrogel/fat graft complex filler has demonstrated the ability of promoting fat pad formation inside the targeted defect area. The newly generated fat pad can cover the whole defect and restore its original dimension in 6-month time point. Compared to simple fat transplantation, this hydrogel/fat graft complex system provides much improvement on long term volume restoration effect against degeneration and volume shrinkage. One notable effect is that there is continuous proliferation of adipose tissue throughout the 6-month period. In summary, the hydrogel/fat graft system presented in this investigation demonstrated a better and more significant effect on volume reconstruction in large sized volume defect than simple fat transplantation.

  11. Sensors, Volume 3, Part II, Chemical and Biochemical Sensors Part II

    NASA Astrophysics Data System (ADS)

    Göpel, Wolfgang; Jones, T. A.; Kleitz, Michel; Lundström, Ingemar; Seiyama, Tetsuro

    1997-06-01

    'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This is the second of two volumes focusing on chemical and biochemical sensors. It includes a detailed description of biosensors which often make use of transducer properties of the basic sensors and usually have additional biological components. This volume provides a unique overview of the applications, the possibilities and limitations of sensors in comparison with conventional instrumentation in analytical chemistry. Specific facettes of applications are presented by specialists from different fields including environmental, biotechnological, medical, or chemical process control. This book is an indispensable reference work for both specialits and newcomers, researchers and developers.

  12. 40 CFR 91.209 - Maintenance of records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., (3) Power rating for each configuration tested, (4) Projected sales volume for the model year, and (5) Actual sales volume for the model year for each FEL where FEL changes have been implemented during the... family, (2) The actual quarterly and cumulative applicable production/sales volume, (3) The values...

  13. Statistical Optics

    NASA Astrophysics Data System (ADS)

    Goodman, Joseph W.

    2000-07-01

    The Wiley Classics Library consists of selected books that have become recognized classics in their respective fields. With these new unabridged and inexpensive editions, Wiley hopes to extend the life of these important works by making them available to future generations of mathematicians and scientists. Currently available in the Series: T. W. Anderson The Statistical Analysis of Time Series T. S. Arthanari & Yadolah Dodge Mathematical Programming in Statistics Emil Artin Geometric Algebra Norman T. J. Bailey The Elements of Stochastic Processes with Applications to the Natural Sciences Robert G. Bartle The Elements of Integration and Lebesgue Measure George E. P. Box & Norman R. Draper Evolutionary Operation: A Statistical Method for Process Improvement George E. P. Box & George C. Tiao Bayesian Inference in Statistical Analysis R. W. Carter Finite Groups of Lie Type: Conjugacy Classes and Complex Characters R. W. Carter Simple Groups of Lie Type William G. Cochran & Gertrude M. Cox Experimental Designs, Second Edition Richard Courant Differential and Integral Calculus, Volume I RIchard Courant Differential and Integral Calculus, Volume II Richard Courant & D. Hilbert Methods of Mathematical Physics, Volume I Richard Courant & D. Hilbert Methods of Mathematical Physics, Volume II D. R. Cox Planning of Experiments Harold S. M. Coxeter Introduction to Geometry, Second Edition Charles W. Curtis & Irving Reiner Representation Theory of Finite Groups and Associative Algebras Charles W. Curtis & Irving Reiner Methods of Representation Theory with Applications to Finite Groups and Orders, Volume I Charles W. Curtis & Irving Reiner Methods of Representation Theory with Applications to Finite Groups and Orders, Volume II Cuthbert Daniel Fitting Equations to Data: Computer Analysis of Multifactor Data, Second Edition Bruno de Finetti Theory of Probability, Volume I Bruno de Finetti Theory of Probability, Volume 2 W. Edwards Deming Sample Design in Business Research

  14. Composite materials. Volume 3 - Engineering applications of composites. Volume 4 - Metallic matrix composites. Volume 8 - Structural design and analysis, Part 2

    NASA Technical Reports Server (NTRS)

    Noton, B. R. (Editor); Kreider, K. G.; Chamis, C. C.

    1974-01-01

    This volume discusses a vaety of applications of both low- and high-cost composite materials in a number of selected engineering fields. The text stresses the use of fiber-reinforced composites, along with interesting material systems used in the electrical and nuclear industries. As to technology transfer, a similarity is noted between many of the reasons responsible for the utilization of composites and those problems requiring urgent solution, such as mechanized fabrication processes and design for production. Features topics include road transportation, rail transportation, civil aircraft, space vehicles, builing industry, chemical plants, and appliances and equipment. The laminate orientation code devised by Air Force materials laboratory is included. Individual items are announced in this issue.

  15. Advanced vehicle systems assessment. Volume 2: Subsystems assessment

    NASA Technical Reports Server (NTRS)

    Hardy, K.

    1985-01-01

    Volume 2 (Subsystems Assessment) is part of a five-volume report entitled Advanced Vehicle Systems Assessment. Volume 2 presents the projected performance capabilities and cost characteristics of applicable subsystems, considering an additional decade of development. Subsystems of interest include energy storage and conversion devices as well as the necessary powertrain components and vehicle subsystems. Volume 2 also includes updated battery information based on the assessment of an independent battery review board (with the aid of subcontractor reports on advanced battery characteristics).

  16. Developing Successful Proposals in Women's Educational Equity, Volume I: The Guide = Desarrollo de propuestas exitosas relacionadas con la equidad educativa de la mujer, volumen I: La guia. Volume II: The Supplement. Volume III: The Swipe File. Volume IV: Workshop Training Manual.

    ERIC Educational Resources Information Center

    Matthews, Walter R.; And Others

    Four volumes present materials and a training workshop on proposal writing. The materials aim to give people the skills and resources with which to translate their ideas into fully developed grant proposals for projects related to educational equity for women. However, the information is applicable to most other funding procedures. The first…

  17. Free Volume Considerations in Thermoplastic and Thermosetting Resins

    NASA Technical Reports Server (NTRS)

    Landel, R. F.; Gupta, A.; Moacanin, J.; Hong, D.; Tsay, F. D.; Chen, S.; Chung, S.; Fedors, R. F.; Cigmecioglu, M.

    1984-01-01

    The direct measurement of physical aging and of the volume changes which go on during the course of this aging is discussed. Data on PMMA showing its physical aging as measured by its stress relaxation response and the accompanying volume changes are presented. An indication of how one can measure the free volume both directly from the volume change itself and relatively directly via a new technique is given. The application of this new technique (electron spin resonance spectroscopy) to other polymer systems is demonstrated.

  18. Are You Bleeding? Validation of a Machine-learning Algorithm for Determination of Blood Volume Status: Application to Remote Triage

    DTIC Science & Technology

    2014-01-09

    workloads were determined by matching heart rate responses from each LBNP level. Heart rate and stroke volume (SV) were measured via Finom- eter. ECG, heat...learning algorithm for the assessment of central blood volume via pulse pressure [a noninvasive surrogate of stroke volume (SV)]. These data...30 130 125 120 115 110 105 100 Actual - Finometer Predicted - Algorithm Fig. 3. Comparison of average stroke volume (SV) derived from the

  19. The importance of applicator design for intraluminal brachytherapy of rectal cancer.

    PubMed

    Hansen, Johnny Witterseh; Jakobsen, Anders

    2006-09-01

    An important aspect of designing an applicator for radiation treatment of rectal cancer is the ability to minimize dose to the mucosa and noninvolved parts of the rectum wall. For this reason we investigated a construction of a flexible multichannel applicator with several channels placed along the periphery of a cylinder and a construction of a rigid cylinder with a central channel and interchangeable shields. Calculations of the dose gradient, dose homogeneity in the tumor, and shielding ability were performed for the two applicators in question. Furthermore, the influence on dose distribution around a flexible multichannel applicator from an unintended off-axis positioning of the source inside a bent channel was investigated by film measurements on a single bent catheter. Calculations showed that a single-channel applicator with interchangeable shields yields a higher degree of shielding and has a better dose homogeneity in the tumor volume than that of a multi-channel applicator. A single-channel applicator with interchangeable shields was manufactured, and the influence of different size of shield angle on dose rate in front of and behind the shields was measured. While dose rate in front of the shield and shielding ability are closely independent of the size of the shield angle when measured 1 cm from the applicator surface, dose rate in more distant volumes will to some extent be influenced by shield angle due to volume scatter conditions.

  20. The importance of applicator design for intraluminal brachytherapy of rectal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Johnny Witterseh; Jakobsen, Anders; Department of Oncology, Hospital of Vejle, DK-7100 Vejle

    2006-09-15

    An important aspect of designing an applicator for radiation treatment of rectal cancer is the ability to minimize dose to the mucosa and noninvolved parts of the rectum wall. For this reason we investigated a construction of a flexible multichannel applicator with several channels placed along the periphery of a cylinder and a construction of a rigid cylinder with a central channel and interchangeable shields. Calculations of the dose gradient, dose homogeneity in the tumor, and shielding ability were performed for the two applicators in question. Furthermore, the influence on dose distribution around a flexible multichannel applicator from an unintendedmore » off-axis positioning of the source inside a bent channel was investigated by film measurements on a single bent catheter. Calculations showed that a single-channel applicator with interchangeable shields yields a higher degree of shielding and has a better dose homogeneity in the tumor volume than that of a multichannel applicator. A single-channel applicator with interchangeable shields was manufactured, and the influence of different size of shield angle on dose rate in front of and behind the shields was measured. While dose rate in front of the shield and shielding ability are closely independent of the size of the shield angle when measured 1 cm from the applicator surface, dose rate in more distant volumes will to some extent be influenced by shield angle due to volume scatter conditions.« less

  1. SU-E-T-611: Effective Treatment Volume of the Small Size IORT Applicators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krechetov, A.S.; ASK Physics, Mountain View, CA; Goer, D.A.

    2014-06-01

    Purpose Mobile electron linear accelerators are gaining more attention recently, providing a lower cost and simpler way to perform intraoperative treatment. However, the simplicity of the treatment process does not eliminate the need for proper attention to the technical aspects of the treatment. One of the potential pitfalls is incorrect selection of the appropriate applicator size to adequately cover the tumor bed to the prescription dose. When treating tumor beds in the pelvis, the largest applicator that fits into the pelvis is usually selected as there is concern about microscopic extension of the disease along the sidewalls of the pelvis.more » But when treating early stage breast tumors, there is a natural tendency to select an applicator as small as possible so as not to jeopardize cosmesis. Methods This investigation questions how much of the typical breast treatment volume gets adequate exposure and what is the correct strategy in selecting the proper applicator size. Actual data from isodose scans were analyzed. Results We found that typical treatment dose prescriptions can cover as much as 80% and as little as 20% of the nominal treatment volume depending on the applicator size and energy of the beam and whether the dose is prescribed to the 80 or 90% isodose level. Treatment volume is defined as a cylinder with diameter equal to applicator and height equal to the corresponding D80 or D90 depth. Conclusion If mobile linear accelerators are used, there can be significant amount of “cold volume” depending on the applicator size and this should be taken into account when selecting the applicator that is needed. Using too small of an applicator could result in significant under-dosing to the tissue at risk. Long-term clinical data demonstrates that selecting an adequate field size results in good ontological control as well as excellent cosmesis. Intraop Medical Corp was providing facilities and equipment for this research.« less

  2. Proceedings of a Workshop on Applications of Tethers in Space, Volume 2

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The panel conclusions for each of the following panels (science applications; electrodynamic interactions; transportation applications; artificial gravity; constellations; and technology and test) are given.

  3. Recent trends in National Institutes of Health funding for surgery: 2003 to 2013.

    PubMed

    Hu, Yinin; Edwards, Brandy L; Brooks, Kendall D; Newhook, Timothy E; Slingluff, Craig L

    2015-06-01

    The purpose of this study is to compare the compositions of federally funded surgical research between 2003 and 2013, and to assess differences in funding trends between surgery and other medical specialties. The National Institutes of Health (NIH) Research Portfolio Online Reporting Tool database was queried for grants within core surgical disciplines during 2003 and 2013. Funding was categorized by award type, methodology, and discipline. Application success rates for surgery and 5 nonsurgical departments were trended over time. Inflation-adjusted NIH funding for surgical research decreased 19% from $270 M in 2003 to $219 M in 2013, with a shift from R-awards to U-awards. Proportional funding to outcomes research almost tripled, while translational research diminished. Nonsurgical departments have increased NIH application volume over the last 10 years; however, surgery's application volume has been stagnant. To preserve surgery's role in innovative research, new efforts are needed to incentivize an increase in application volume. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Recent trends in National Institutes of Health Funding for Surgery: 2003 to 2013

    PubMed Central

    Hu, Yinin; Edwards, Brandy L.; Brooks, Kendall D.; Newhook, Timothy; Slingluff, Craig L.

    2015-01-01

    BACKGROUND The purpose of this study is to compare the compositions of federally-funded surgical research between 2003 and 2013, and to assess differences in funding trends between surgery and other medical specialties. DATA SOURCES The NIH RePORTER database was queried for grants within core surgical disciplines during 2003 and 2013. Funding was categorized by award type, methodology, and discipline. Application success rates for surgery and five non-surgical departments were trended over time. RESULTS Inflation-adjusted NIH funding for surgical research decreased 19% from $270M in 2003 to $219M in 2013, with a shift from R-awards to U-awards. Proportional funding to outcomes research almost tripled, while translational research diminished. Non-surgical departments have increased NIH application volume over the last 10 years; however, surgery’s application volume has been stagnant. CONCLUSIONS To preserve surgery’s role in innovative research, new efforts are needed to incentivize an increase in application volume. PMID:25929766

  5. Market projections of cellulose nanomaterial-enabled products-- Part 2: Volume estimates

    Treesearch

    John Cowie; E.M. (Ted) Bilek; Theodore H. Wegner; Jo Anne Shatkin

    2014-01-01

    Nanocellulose has enormous potential to provide an important materials platform in numerous product sectors. This study builds on previous work by the same authors in which likely high-volume, low-volume, and novel applications for cellulosic nanomaterials were identified. In particular, this study creates a transparent methodology and estimates the potential annual...

  6. Monitored Natural Attenuation of Inorganic Contaminants in Ground Water Volume 1 – Technical Basis for Assessment

    EPA Science Inventory

    This document represents the first volume of a set of three volumes that address the technical basis and requirements for assessing the potential applicability of MNA as part of a ground-water remedy for plumes with non-radionuclide and/or radionuclide inorganic contaminants. Vo...

  7. CO2 storage resources, reserves, and reserve growth: Toward a methodology for integrated assessment of the storage capacity of oil and gas reservoirs and saline formations

    USGS Publications Warehouse

    Burruss, Robert

    2009-01-01

    Geologically based methodologies to assess the possible volumes of subsurface CO2 storage must apply clear and uniform definitions of resource and reserve concepts to each assessment unit (AU). Application of the current state of knowledge of geologic, hydrologic, geochemical, and geophysical parameters (contingencies) that control storage volume and injectivity allows definition of the contingent resource (CR) of storage. The parameters known with the greatest certainty are based on observations on known traps (KTs) within the AU that produced oil, gas, and water. The aggregate volume of KTs within an AU defines the most conservation volume of contingent resource. Application of the concept of reserve growth to CR volume provides a logical path for subsequent reevaluation of the total resource as knowledge of CO2 storage processes increases during implementation of storage projects. Increased knowledge of storage performance over time will probably allow the volume of the contingent resource of storage to grow over time, although negative growth is possible.

  8. CO2 storage resources, reserves, and reserve growth: Toward a methodology for integrated assessment of the storage capacity of oil and gas reservoirs and saline formations

    USGS Publications Warehouse

    Burruss, R.C.

    2009-01-01

    Geologically based methodologies to assess the possible volumes of subsurface CO2 storage must apply clear and uniform definitions of resource and reserve concepts to each assessment unit (AU). Application of the current state of knowledge of geologic, hydrologic, geochemical, and geophysical parameters (contingencies) that control storage volume and injectivity allows definition of the contingent resource (CR) of storage. The parameters known with the greatest certainty are based on observations on known traps (KTs) within the AU that produced oil, gas, and water. The aggregate volume of KTs within an AU defines the most conservation volume of contingent resource. Application of the concept of reserve growth to CR volume provides a logical path for subsequent reevaluation of the total resource as knowledge of CO2 storage processes increases during implementation of storage projects. Increased knowledge of storage performance over time will probably allow the volume of the contingent resource of storage to grow over time, although negative growth is possible. ?? 2009 Elsevier Ltd. All rights reserved.

  9. Sensors, Volume 1, Fundamentals and General Aspects

    NASA Astrophysics Data System (ADS)

    Grandke, Thomas; Ko, Wen H.

    1996-12-01

    'Sensors' is the first self-contained series to deal with the whole area of sensors. It describes general aspects, technical and physical fundamentals, construction, function, applications and developments of the various types of sensors. This volume deals with the fundamentals and common principles of sensors and covers the wide areas of principles, technologies, signal processing, and applications. Contents include: Sensor Fundamentals, e.g. Sensor Parameters, Modeling, Design and Packaging; Basic Sensor Technologies, e.g. Thin and Thick Films, Integrated Magnetic Sensors, Optical Fibres and Intergrated Optics, Ceramics and Oxides; Sensor Interfaces, e.g. Signal Processing, Multisensor Signal Processing, Smart Sensors, Interface Systems; Sensor Applications, e.g. Automotive: On-board Sensors, Traffic Surveillance and Control, Home Appliances, Environmental Monitoring, etc. This volume is an indispensable reference work and text book for both specialits and newcomers, researchers and developers.

  10. Variations of comoving volume and their effects on the star formation rate density

    NASA Astrophysics Data System (ADS)

    Kim, Sungeun; Physics and Astronomy, Sejong University, Seoul, Korea (the Republic of).

    2018-01-01

    To build a comprehensive picture of star formation in the universe, we havedeveloped an application to calculate the comoving volume at a specific redshift and visualize the changes of spaceand time. The application is based on the star formation rates of about a few thousands of galaxies and their redshiftvalues. Three dimensional modeling of these galaxies using the redshift, comoving volume, and star formation ratesas input data allows calculation of the star formation rate density corresponding to the redshift. This work issupported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP)(no. 2017037333).

  11. Fundamentals of electric power conversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umans, S.D.

    1992-12-01

    Its rugged nature and straightforward design make the induction motor the most commonly used type of electric motor. This motor ranges in size from the fractional-horsepower, single-phase motors found in household appliances to polyphase motors rated at thousands of horsepower for industrial applications. Volume 1 of this report describes the function of induction motors, their characteristics, and induction motor testing. Volume 2 describes the characteristics of high-efficiency induction motors, with emphasis on the techniques used to obtain high efficiency. This two-volume report is written in nontechnical language and is intended for readers who require background from an applications, marketing, motormore » planning, or managerial perspective.« less

  12. Fundamentals of electric power conversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umans, S.D.

    1992-12-01

    Its rugged nature and straightforward design make the induction motor the most commonly used type of electric motor. This motor ranges in size fro the fractional-horsepower, single-phase motors found in household appliances to polyphase motors rated at thousands of horsepower for industrial applications. Volume 1 of this report describes the function of induction motors, their characteristics, and induction motor testing. Volume 2 describes the characteristics of high-efficiency induction motors, with emphasis on the techniques used to obtain high efficiency. This two-volume report is written in nontechnical language and is intended for readers who require background from applications, marketing, motor planning,more » or managerial perspective.« less

  13. Real-time volume rendering of digital medical images on an iOS device

    NASA Astrophysics Data System (ADS)

    Noon, Christian; Holub, Joseph; Winer, Eliot

    2013-03-01

    Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.

  14. Osmosis-Based Pressure Generation: Dynamics and Application

    PubMed Central

    Li, Suyi; Billeh, Yazan N.; Wang, K. W.; Mayer, Michael

    2014-01-01

    This paper describes osmotically-driven pressure generation in a membrane-bound compartment while taking into account volume expansion, solute dilution, surface area to volume ratio, membrane hydraulic permeability, and changes in osmotic gradient, bulk modulus, and degree of membrane fouling. The emphasis lies on the dynamics of pressure generation; these dynamics have not previously been described in detail. Experimental results are compared to and supported by numerical simulations, which we make accessible as an open source tool. This approach reveals unintuitive results about the quantitative dependence of the speed of pressure generation on the relevant and interdependent parameters that will be encountered in most osmotically-driven pressure generators. For instance, restricting the volume expansion of a compartment allows it to generate its first 5 kPa of pressure seven times faster than without a restraint. In addition, this dynamics study shows that plants are near-ideal osmotic pressure generators, as they are composed of many small compartments with large surface area to volume ratios and strong cell wall reinforcements. Finally, we demonstrate two applications of an osmosis-based pressure generator: actuation of a soft robot and continuous volume delivery over long periods of time. Both applications do not need an external power source but rather take advantage of the energy released upon watering the pressure generators. PMID:24614529

  15. Volume Holograms in Photopolymers: Comparison between Analytical and Rigorous Theories

    PubMed Central

    Gallego, Sergi; Neipp, Cristian; Estepa, Luis A.; Ortuño, Manuel; Márquez, Andrés; Francés, Jorge; Pascual, Inmaculada; Beléndez, Augusto

    2012-01-01

    There is no doubt that the concept of volume holography has led to an incredibly great amount of scientific research and technological applications. One of these applications is the use of volume holograms as optical memories, and in particular, the use of a photosensitive medium like a photopolymeric material to record information in all its volume. In this work we analyze the applicability of Kogelnik’s Coupled Wave theory to the study of volume holograms recorded in photopolymers. Some of the theoretical models in the literature describing the mechanism of hologram formation in photopolymer materials use Kogelnik’s theory to analyze the gratings recorded in photopolymeric materials. If Kogelnik’s theory cannot be applied is necessary to use a more general Coupled Wave theory (CW) or the Rigorous Coupled Wave theory (RCW). The RCW does not incorporate any approximation and thus, since it is rigorous, permits judging the accurateness of the approximations included in Kogelnik’s and CW theories. In this article, a comparison between the predictions of the three theories for phase transmission diffraction gratings is carried out. We have demonstrated the agreement in the prediction of CW and RCW and the validity of Kogelnik’s theory only for gratings with spatial frequencies higher than 500 lines/mm for the usual values of the refractive index modulations obtained in photopolymers.

  16. A simple method for the production of large volume 3D macroporous hydrogels for advanced biotechnological, medical and environmental applications

    NASA Astrophysics Data System (ADS)

    Savina, Irina N.; Ingavle, Ganesh C.; Cundy, Andrew B.; Mikhalovsky, Sergey V.

    2016-02-01

    The development of bulk, three-dimensional (3D), macroporous polymers with high permeability, large surface area and large volume is highly desirable for a range of applications in the biomedical, biotechnological and environmental areas. The experimental techniques currently used are limited to the production of small size and volume cryogel material. In this work we propose a novel, versatile, simple and reproducible method for the synthesis of large volume porous polymer hydrogels by cryogelation. By controlling the freezing process of the reagent/polymer solution, large-scale 3D macroporous gels with wide interconnected pores (up to 200 μm in diameter) and large accessible surface area have been synthesized. For the first time, macroporous gels (of up to 400 ml bulk volume) with controlled porous structure were manufactured, with potential for scale up to much larger gel dimensions. This method can be used for production of novel 3D multi-component macroporous composite materials with a uniform distribution of embedded particles. The proposed method provides better control of freezing conditions and thus overcomes existing drawbacks limiting production of large gel-based devices and matrices. The proposed method could serve as a new design concept for functional 3D macroporous gels and composites preparation for biomedical, biotechnological and environmental applications.

  17. Longevity of ultra-low-volume sprays of fipronil and malathion on cotton in Mexico

    Treesearch

    Joseph E. Mulrooney; K.A. Holmes; R.A. Shaw; D. Goli

    2003-01-01

    In 1996, fipronil and malathion residues were evaluated after four ultra-low-volume (ULV) spray applications in northeastern Tarnaulipas, Mexico. Sprays were applied at 0.88 L/ha. Fipronil was applied at 28 and 56 g A.I./ha and malathion at 840 g A.I./ha. Four applications were made beginning 23 May at four, five and six day intervals. Leaf surface residues of...

  18. Formal Methods Specification and Verification Guidebook for Software and Computer Systems. Volume 1; Planning and Technology Insertion

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Formal Methods Specification and Verification Guidebook for Software and Computer Systems describes a set of techniques called Formal Methods (FM), and outlines their use in the specification and verification of computer systems and software. Development of increasingly complex systems has created a need for improved specification and verification techniques. NASA's Safety and Mission Quality Office has supported the investigation of techniques such as FM, which are now an accepted method for enhancing the quality of aerospace applications. The guidebook provides information for managers and practitioners who are interested in integrating FM into an existing systems development process. Information includes technical and administrative considerations that must be addressed when establishing the use of FM on a specific project. The guidebook is intended to aid decision makers in the successful application of FM to the development of high-quality systems at reasonable cost. This is the first volume of a planned two-volume set. The current volume focuses on administrative and planning considerations for the successful application of FM.

  19. Developing a method for estimating AADT on all Louisiana roads.

    DOT National Transportation Integrated Search

    2015-07-01

    Traffic flow volumes present key information needed for making transportation engineering and planning decisions. : Accurate traffic volume count has many applications including: roadway planning, design, air quality compliance, travel : model valida...

  20. 46 CFR 195.30-1 - Application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...

  1. 46 CFR 195.30-1 - Application.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...

  2. 46 CFR 195.30-1 - Application.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...

  3. 46 CFR 195.30-1 - Application.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...

  4. 46 CFR 195.30-1 - Application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... is equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of...

  5. A multiresolution approach to iterative reconstruction algorithms in X-ray computed tomography.

    PubMed

    De Witte, Yoni; Vlassenbroeck, Jelle; Van Hoorebeke, Luc

    2010-09-01

    In computed tomography, the application of iterative reconstruction methods in practical situations is impeded by their high computational demands. Especially in high resolution X-ray computed tomography, where reconstruction volumes contain a high number of volume elements (several giga voxels), this computational burden prevents their actual breakthrough. Besides the large amount of calculations, iterative algorithms require the entire volume to be kept in memory during reconstruction, which quickly becomes cumbersome for large data sets. To overcome this obstacle, we present a novel multiresolution reconstruction, which greatly reduces the required amount of memory without significantly affecting the reconstructed image quality. It is shown that, combined with an efficient implementation on a graphical processing unit, the multiresolution approach enables the application of iterative algorithms in the reconstruction of large volumes at an acceptable speed using only limited resources.

  6. Dynamic modeling of photothermal interactions for laser-induced interstitial thermotherapy: parameter sensitivity analysis.

    PubMed

    Jiang, S C; Zhang, X X

    2005-12-01

    A two-dimensional model was developed to model the effects of dynamic changes in the physical properties on tissue temperature and damage to simulate laser-induced interstitial thermotherapy (LITT) treatment procedures with temperature monitoring. A modified Monte Carlo method was used to simulate photon transport in the tissue in the non-uniform optical property field with the finite volume method used to solve the Pennes bioheat equation to calculate the temperature distribution and the Arrhenius equation used to predict the thermal damage extent. The laser light transport and the heat transfer as well as the damage accumulation were calculated iteratively at each time step. The influences of different laser sources, different applicator sizes, and different irradiation modes on the final damage volume were analyzed to optimize the LITT treatment. The numerical results showed that damage volume was the smallest for the 1,064-nm laser, with much larger, similar damage volumes for the 980- and 850-nm lasers at normal blood perfusion rates. The damage volume was the largest for the 1,064-nm laser with significantly smaller, similar damage volumes for the 980- and 850-nm lasers with temporally interrupted blood perfusion. The numerical results also showed that the variations in applicator sizes, laser powers, heating durations and temperature monitoring ranges significantly affected the shapes and sizes of the thermal damage zones. The shapes and sizes of the thermal damage zones can be optimized by selecting different applicator sizes, laser powers, heating duration times, temperature monitoring ranges, etc.

  7. Multivariate regression model for partitioning tree volume of white oak into round-product classes

    Treesearch

    Daniel A. Yaussy; David L. Sonderman

    1984-01-01

    Describes the development of multivariate equations that predict the expected cubic volume of four round-product classes from independent variables composed of individual tree-quality characteristics. Although the model has limited application at this time, it does demonstrate the feasibility of partitioning total tree cubic volume into round-product classes based on...

  8. Volume, Conservation and Instruction: A Classroom Based Solomon Four Group Study of Conflict.

    ERIC Educational Resources Information Center

    Rowell, J. A.; Dawson, C. J.

    1981-01-01

    Summarizes a study to widen the applicability of Piagetian theory-based conflict methodology from individual situations to entire classes. A Solomon four group design was used to study effects of conflict instruction on students' (N=127) ability to conserve volume of noncompressible matter and to apply that knowledge to gas volume. (Author/JN)

  9. 33 CFR 154.1035 - Specific requirements for facilities that could reasonably be expected to cause significant and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... spill mitigation procedures. (i) This subsection must describe the volume(s) and oil groups that would... applicable, the worst case discharge from the non-transportation-related facility. This must be the same volume provided in the response plan for the non-transportation-related facility. (ii) This subsection...

  10. Disposable photonic integrated circuits for evanescent wave sensors by ultra-high volume roll-to-roll method.

    PubMed

    Aikio, Sanna; Hiltunen, Jussi; Hiitola-Keinänen, Johanna; Hiltunen, Marianne; Kontturi, Ville; Siitonen, Samuli; Puustinen, Jarkko; Karioja, Pentti

    2016-02-08

    Flexible photonic integrated circuit technology is an emerging field expanding the usage possibilities of photonics, particularly in sensor applications, by enabling the realization of conformable devices and introduction of new alternative production methods. Here, we demonstrate that disposable polymeric photonic integrated circuit devices can be produced in lengths of hundreds of meters by ultra-high volume roll-to-roll methods on a flexible carrier. Attenuation properties of hundreds of individual devices were measured confirming that waveguides with good and repeatable performance were fabricated. We also demonstrate the applicability of the devices for the evanescent wave sensing of ambient refractive index. The production of integrated photonic devices using ultra-high volume fabrication, in a similar manner as paper is produced, may inherently expand methods of manufacturing low-cost disposable photonic integrated circuits for a wide range of sensor applications.

  11. Feasibility of intra-acquisition motion correction for 4D DSA reconstruction for applications in the thorax and abdomen

    NASA Astrophysics Data System (ADS)

    Wagner, Martin; Laeseke, Paul; Harari, Colin; Schafer, Sebastian; Speidel, Michael; Mistretta, Charles

    2018-03-01

    The recently proposed 4D DSA technique enables reconstruction of time resolved 3D volumes from two C-arm CT acquisitions. This provides information on the blood flow in neurovascular applications and can be used for the diagnosis and treatment of vascular diseases. For applications in the thorax and abdomen, respiratory motion can prevent successful 4D DSA reconstruction and cause severe artifacts. The purpose of this work is to propose a novel technique for motion compensated 4D DSA reconstruction to enable applications in the thorax and abdomen. The approach uses deformable 2D registration to align the projection images of a non-contrast and a contrast enhanced scan. A subset of projection images is then selected, which are acquired in a similar respiratory state and an iterative simultaneous multiplicative algebraic reconstruction is applied to determine a 3D constraint volume. A 2D-3D registration step then aligns the remaining projection images with the 3D constraint volume. Finally, a constrained back-projection is performed to create a 3D volume for each projection image. A pig study has been performed, where 4D DSA acquisitions were performed with and without respiratory motion to evaluate the feasibility of the approach. The dice similarity coefficient between the reference 3D constraint volume and the motion compensated reconstruction was 51.12 % compared to 35.99 % without motion compensation. This technique could improve the workflow for procedures in interventional radiology, e.g. liver embolizations, where changes in blood flow have to be monitored carefully.

  12. 46 CFR 96.30-1 - Application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...

  13. 46 CFR 96.30-1 - Application.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...

  14. 46 CFR 96.30-1 - Application.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...

  15. 46 CFR 96.30-1 - Application.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...

  16. 46 CFR 96.30-1 - Application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than... equipped with any refrigeration unit using— (1) Ammonia to refrigerate any space with a volume of more than...

  17. Less and less-influence of volume on hand coverage and bactericidal efficacy in hand disinfection.

    PubMed

    Kampf, Günter; Ruselack, Sigunde; Eggerstedt, Sven; Nowak, Nicolas; Bashir, Muhammad

    2013-10-10

    Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Volumes < 2 mL yielded high rates of incomplete coverage (67%-87%) whereas volumes ≥ 2 mL gave lower rates (13%-53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755-10. Our data indicated that handrubs based on 70% ethanol (v/v) with a recommended volume of 1.1 mL per application do not ensure complete coverage of both hands and do not achieve current ASTM efficacy standards.

  18. Elasticity-based three dimensional ultrasound real-time volume rendering

    NASA Astrophysics Data System (ADS)

    Boctor, Emad M.; Matinfar, Mohammad; Ahmad, Omar; Rivaz, Hassan; Choti, Michael; Taylor, Russell H.

    2009-02-01

    Volumetric ultrasound imaging has not gained wide recognition, despite the availability of real-time 3D ultrasound scanners and the anticipated potential of 3D ultrasound imaging in diagnostic and interventional radiology. Their use, however, has been hindered by the lack of real-time visualization methods that are capable of producing high quality 3D rendering of the target/surface of interest. Volume rendering is a known visualization method, which can display clear surfaces out of the acquired volumetric data, and has an increasing number of applications utilizing CT and MRI data. The key element of any volume rendering pipeline is the ability to classify the target/surface of interest by setting an appropriate opacity function. Practical and successful real-time 3D ultrasound volume rendering can be achieved in Obstetrics and Angio applications where setting these opacity functions can be done rapidly, and reliably. Unfortunately, 3D ultrasound volume rendering of soft tissues is a challenging task due to the presence of significant amount of noise and speckle. Recently, several research groups have shown the feasibility of producing 3D elasticity volume from two consecutive 3D ultrasound scans. This report describes a novel volume rendering pipeline utilizing elasticity information. The basic idea is to compute B-mode voxel opacity from the rapidly calculated strain values, which can also be mixed with conventional gradient based opacity function. We have implemented the volume renderer using GPU unit, which gives an update rate of 40 volume/sec.

  19. Substantial Expansion of Detectable Size Range in Ionic Current Sensing through Pores by Using a Microfluidic Bridge Circuit.

    PubMed

    Yasaki, Hirotoshi; Yasui, Takao; Yanagida, Takeshi; Kaji, Noritada; Kanai, Masaki; Nagashima, Kazuki; Kawai, Tomoji; Baba, Yoshinobu

    2017-10-11

    Measuring ionic currents passing through nano- or micropores has shown great promise for the electrical discrimination of various biomolecules, cells, bacteria, and viruses. However, conventional measurements have shown there is an inherent limitation to the detectable particle volume (1% of the pore volume), which critically hinders applications to real mixtures of biomolecule samples with a wide size range of suspended particles. Here we propose a rational methodology that can detect samples with the detectable particle volume of 0.01% of the pore volume by measuring a transient current generated from the potential differences in a microfluidic bridge circuit. Our method substantially suppresses the background ionic current from the μA level to the pA level, which essentially lowers the detectable particle volume limit even for relatively large pore structures. Indeed, utilizing a microscale long pore structure (volume of 5.6 × 10 4 aL; height and width of 2.0 × 2.0 μm; length of 14 μm), we successfully detected various samples including polystyrene nanoparticles (volume: 4 aL), bacteria, cancer cells, and DNA molecules. Our method will expand the applicability of ionic current sensing systems for various mixed biomolecule samples with a wide size range, which have been difficult to measure by previously existing pore technologies.

  20. Energy-state formulation of lumped volume dynamic equations with application to a simplified free piston Stirling engine

    NASA Technical Reports Server (NTRS)

    Daniele, C. J.; Lorenzo, C. F.

    1979-01-01

    Lumped volume dynamic equations are derived using an energy state formulation. This technique requires that kinetic and potential energy state functions be written for the physical system being investigated. To account for losses in the system, a Rayleigh dissipation function is formed. Using these functions, a Lagrangian is formed and using Lagrange's equation, the equations of motion for the system are derived. The results of the application of this technique to a lumped volume are used to derive a model for the free piston Stirling engine. The model was simplified and programmed on an analog computer. Results are given comparing the model response with experimental data.

  1. Energy-state formulation of lumped volume dynamic equations with application to a simplified free piston Stirling engine

    NASA Technical Reports Server (NTRS)

    Daniele, C. J.; Lorenzo, C. F.

    1979-01-01

    Lumped volume dynamic equations are derived using an energy-state formulation. This technique requires that kinetic and potential energy state functions be written for the physical system being investigated. To account for losses in the system, a Rayleigh dissipation function is also formed. Using these functions, a Lagrangian is formed and using Lagrange's equation, the equations of motion for the system are derived. The results of the application of this technique to a lumped volume are used to derive a model for the free-piston Stirling engine. The model was simplified and programmed on an analog computer. Results are given comparing the model response with experimental data.

  2. Stratified Diffractive Optic Approach for Creating High Efficiency Gratings

    NASA Technical Reports Server (NTRS)

    Chambers, Diana M.; Nordin, Gregory P.

    1998-01-01

    Gratings with high efficiency in a single diffracted order can be realized with both volume holographic and diffractive optical elements. However, each method has limitations that restrict the applications in which they can be used. For example, high efficiency volume holographic gratings require an appropriate combination of thickness and permittivity modulation throughout the bulk of the material. Possible combinations of those two characteristics are limited by properties of currently available materials, thus restricting the range of applications for volume holographic gratings. Efficiency of a diffractive optic grating is dependent on its approximation of an ideal analog profile using discrete features. The size of constituent features and, consequently, the number that can be used within a required grating period restricts the applications in which diffractive optic gratings can be used. These limitations imply that there are applications which cannot be addressed by either technology. In this paper we propose to address a number of applications in this category with a new method of creating high efficiency gratings which we call stratified diffractive optic gratings. In this approach diffractive optic techniques are used to create an optical structure that emulates volume grating behavior. To illustrate the stratified diffractive optic grating concept we consider a specific application, a scanner for a space-based coherent wind lidar, with requirements that would be difficult to meet by either volume holographic or diffractive optic methods. The lidar instrument design specifies a transmissive scanner element with the input beam normally incident and the exiting beam deflected at a fixed angle from the optical axis. The element will be rotated about the optical axis to produce a conical scan pattern. The wavelength of the incident beam is 2.06 microns and the required deflection angle is 30 degrees, implying a grating period of approximately 4 microns. Creating a high efficiency volume grating with these parameters would require a grating thickness that cannot be attained with current photosensitive materials. For a diffractive optic grating, the number of binary steps necessary to produce high efficiency combined with the grating period requires feature sizes and alignment tolerances that are also unattainable with current techniques. Rotation of the grating and integration into a space-based lidar system impose the additional requirements that it be insensitive to polarization orientation, that its mass be minimized and that it be able to withstand launch and space environments.

  3. Right-Turn Traffic Volume Adjustments in Traffic Signal Warrant Analysis

    DOT National Transportation Integrated Search

    2015-01-01

    To accomplish this research, a comprehensive literature review of existing guidelines and findings based on national and local studies was conducted. Ultimately, guidelines for consistent application for adjusting right-turn traffic volumes were deve...

  4. A method of estimating cubic volume in felled trees

    Treesearch

    Frederick E. Hampf; C. Allen Bickford

    1959-01-01

    This paper describes a new method of computing the gross volume of felled trees or sections of trees. The method has many applications, but most are limited to forest research and management, especially in making surveys.

  5. Marine safety manual, volume 4 : technical

    DOT National Transportation Integrated Search

    2005-01-01

    A comprehensive manual which provides guidance on the application of Coast Guard regulations and explains the rationale behind their development is vital to the successful execution of the marine safety program. This volume is intended to serve that ...

  6. Estimating value and volume of ponderosa pine trees by equations.

    Treesearch

    Martin E. Plank

    1981-01-01

    Equations for estimating the selling value and tally volume for ponderosa pine lumber from the standing trees are described. Only five characteristics are required for the equations. Development and application of the system are described.

  7. Wayside Energy Storage Study : Volume 1. Summary.

    DOT National Transportation Integrated Search

    1979-02-01

    Volume I summarizes an in-depth application study which was conducted to determine the practicality and viability of using large wayside flywheels to recuperate braking energy from freight trains on long downgrades. The study examined the route struc...

  8. Methodology update for estimating volume to service flow ratio.

    DOT National Transportation Integrated Search

    2015-12-01

    Volume/service flow ratio (VSF) is calculated by the Highway Performance Monitoring System (HPMS) software as an indicator of peak hour congestion. It is an essential input to the Kentucky Transportation Cabinets (KYTC) key planning applications, ...

  9. Monitored Natural Attenuation of Inorganic Contaminants in Ground Water Volume 3 Assessment for Radionuclides IncludingTritium, Radon, Strontium, Technetium, Uranium, Iodine, Radium, Thorium, Cesium, and Plutonium-Americium

    EPA Science Inventory

    The current document represents the third volume of a set of three volumes that address the technical basis and requirements for assessing the potential applicability of MNA as part of a ground-water remedy for plumes with nonradionuclide and/or radionuclide inorganic contamina...

  10. Regional Differences in Brain Volume Predict the Acquisition of Skill in a Complex Real-Time Strategy Videogame

    ERIC Educational Resources Information Center

    Basak, Chandramallika; Voss, Michelle W.; Erickson, Kirk I.; Boot, Walter R.; Kramer, Arthur F.

    2011-01-01

    Previous studies have found that differences in brain volume among older adults predict performance in laboratory tasks of executive control, memory, and motor learning. In the present study we asked whether regional differences in brain volume as assessed by the application of a voxel-based morphometry technique on high resolution MRI would also…

  11. Monitored Attenuation of Inorganic Contaminants in Ground Water Volume 2 – Assessment for Non-Radionuclides Including Arsenic, Cadmium, Chromium, Copper, Lead, Nickel, Nitrate, Perchlorate, and Selenium

    EPA Science Inventory

    This document represents the second volume of a set of three volumes that address the technical basis and requirements for assessing the potential applicability of MNA as part of a ground-water remedy for plumes with non-radionuclide and/or radionuclide inorganic contaminants. V...

  12. Focus on Evaluation and Measurement. Proceedings of the National Research Symposium on Limited English Proficient Student Issues (Washington, D.C., September 1991). Volumes 1 and 2.

    ERIC Educational Resources Information Center

    1992

    This document is comprised of a two-volume conference proceedings. The first volume includes the following papers: "Application of Multiple Intelligences: Research in Alternative Assessment" (Joseph Walters) Discussants: Vera John-Steiner, Sue Teele; "Improving Bilingual Education Programs through Evaluation" (Alan L. Ginsburg); "Language Testing…

  13. Aids to navigation service force mix 2000 project. Volume 2 : development and application of an aids to navigation service force mix decision support system : aid assignments and vessel summary reports

    DOT National Transportation Integrated Search

    1992-06-01

    The Aids to Navigation (ATON) Service Force Mix (SFM) 2000 Project is documented in a Project Overview and three separately bound volumes. This is Volume II. The Project Overview describes the purpose, approach, analysis, and results of the ATON SFM ...

  14. Hydration and blood volume effects on human thermoregulation in the heat: Space applications

    NASA Technical Reports Server (NTRS)

    Sawka, Michael N.; Gonzalez, Richard R.; Pandolf, Kent B.

    1994-01-01

    Astronauts exposed to prolonged weightlessness will experience deconditioning, dehydration, and hypovolemia which all adversely affect thermoregulation. These thermoregulatory problems can be minimized by several countermeasures that manipulate body water and vascular volumes. USARIEM scientists have extensively studied dehydration effects and several possible countermeasures including hyperhydration, plasma and erythrocyte volume expansion. This paper reviews USARIEM research into these areas.

  15. Applications for carbon fibre recovered from composites

    NASA Astrophysics Data System (ADS)

    Pickering; Liu, Z.; Turner, TA; Wong, KH

    2016-07-01

    Commercial operations to recover carbon fibre from waste composites are now developing and as more recovered fibre becomes available new applications for recovered fibre are required. Opportunities to use recovered carbon fibre as a structural reinforcement are considered involving the use of wet lay processes to produce nonwoven mats. Mats with random in-plane fibre orientation can readily be produced using existing commercial processes. However, the fibre volume fraction, and hence the mechanical properties that can be achieved, result in composites with limited mechanical properties. Fibre volume fractions of 40% can be achieved with high moulding pressures of over 100 bar, however, moulding at these pressures results in substantial fibre breakage which reduces the mean fibre length and the properties of the composite manufactured. Nonwoven mats made from aligned, short carbon fibres can achieve higher fibre volume fractions with lower fibre breakage even at high moulding pressure. A process for aligning short fibres is described and a composite of over 60% fibre volume fraction has been manufactured at a pressures up to 100 bar with low fibre breakage. Further developments of the alignment process have been undertaken and a composite of 46% fibre volume fraction has been produced moulded at a pressure of 7 bar in an autoclave, exhibiting good mechanical properties that compete with higher grade materials. This demonstrates the potential for high value applications for recovered carbon fibre by fibre alignment.

  16. A simple method for the production of large volume 3D macroporous hydrogels for advanced biotechnological, medical and environmental applications

    PubMed Central

    Savina, Irina N.; Ingavle, Ganesh C.; Cundy, Andrew B.; Mikhalovsky, Sergey V.

    2016-01-01

    The development of bulk, three-dimensional (3D), macroporous polymers with high permeability, large surface area and large volume is highly desirable for a range of applications in the biomedical, biotechnological and environmental areas. The experimental techniques currently used are limited to the production of small size and volume cryogel material. In this work we propose a novel, versatile, simple and reproducible method for the synthesis of large volume porous polymer hydrogels by cryogelation. By controlling the freezing process of the reagent/polymer solution, large-scale 3D macroporous gels with wide interconnected pores (up to 200 μm in diameter) and large accessible surface area have been synthesized. For the first time, macroporous gels (of up to 400 ml bulk volume) with controlled porous structure were manufactured, with potential for scale up to much larger gel dimensions. This method can be used for production of novel 3D multi-component macroporous composite materials with a uniform distribution of embedded particles. The proposed method provides better control of freezing conditions and thus overcomes existing drawbacks limiting production of large gel-based devices and matrices. The proposed method could serve as a new design concept for functional 3D macroporous gels and composites preparation for biomedical, biotechnological and environmental applications. PMID:26883390

  17. Airborne chemistry: acoustic levitation in chemical analysis.

    PubMed

    Santesson, Sabina; Nilsson, Staffan

    2004-04-01

    This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape()and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications. The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL-2 microL volume range and additions to the levitated drop can be made in the pL-volume range. The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell-cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.

  18. Effects of pesticides aerial applications on rice quality

    USDA-ARS?s Scientific Manuscript database

    Aerial application of pesticides has become an important research topic in recent years. This research investigated the effects of two types of commercial pesticides on the rice quality under low volume aerial application. It could provide guidance for the pesticide application and choose the right ...

  19. Characterization of Large Volume CLYC Scintillators for Nuclear Security Applications

    NASA Astrophysics Data System (ADS)

    Soundara-Pandian, Lakshmi; Tower, J.; Hines, C.; O'Dougherty, P.; Glodo, J.; Shah, K.

    2017-07-01

    We report on our development of large volume Cs2LiYCl6 (CLYC) detectors for nuclear security applications. Three-inch diameter boules have been grown and 3-in right cylinders have been fabricated. Crystals containing either >95% 6Li or >99% 7Li have been grown for applications specific to thermal or fast neutron detection, respectively. We evaluated their gamma and neutron detection properties and the performance is as good as small size crystals. Gamma and neutron efficiencies were measured for large crystals and compared with smaller size crystals. With their excellent performance characteristics, and the ability to detect fast neutrons, CLYC detectors are excellent triple-mode scintillators for use in handheld and backpack instruments for nuclear security applications.

  20. Risk Assessment Guidance for Superfund (RAGS) Volume III: Part A

    EPA Pesticide Factsheets

    EPA's Risk Assessment Guidance for Superfund (RAGS) Volume 3A provides policies and guiding principles on the application of probabilistic risk assessment (PRA) methods to human health and ecological risk assessment in the EPA Superfund Program.

  1. Effect of water volume based on water absorption and mixing time on physical properties of tapioca starch – wheat composite bread

    NASA Astrophysics Data System (ADS)

    Prameswari, I. K.; Manuhara, G. J.; Amanto, B. S.; Atmaka, W.

    2018-05-01

    Tapioca starch application in bread processing change water absorption level by the dough, while sufficient mixing time makes the optimal water absorption. This research aims to determine the effect of variations in water volume and mixing time on physical properties of tapioca starch – wheat composite bread and the best method for the composite bread processing. This research used Complete Randomized Factorial Design (CRFD) with two factors: variations of water volume (111,8 ml, 117,4 ml, 123 ml) and mixing time (16 minutes, 17 minutes 36 seconds, 19 minutes 12 seconds). The result showed that water volume significantly affected on dough volume, bread volume and specific volume, baking expansion, and crust thickness. Mixing time significantly affected on dough volume and specific volume, bread volume and specific volume, baking expansion, bread height, and crust thickness. While the combination of water volume and mixing time significantly affected for all physical properties parameters except crust thickness.

  2. Theoretical design and evaluation of endoluminal ultrasound applicators for thermal therapy of pancreatic cancer under image guidance

    NASA Astrophysics Data System (ADS)

    Adams, Matthew; Scott, Serena; Salgaonkar, Vasant; Sommer, Graham; Diederich, Chris

    2017-03-01

    An image-guided endoluminal ultrasound applicator has been proposed for palliative and potential curative thermal therapy of pancreatic tumors. By considering a directional transducer array of planar, tubular, or curvilinear transducers, this design offers the potential for fast volumetric therapy and 3D spatial control over the energy deposition profile. Treatment of pancreatic tumor tissue would be performed in a minimally invasive fashion with the applicator positioned in the gastrointestinal (GI) lumen, and sparing of the luminal wall would be achieved with a water-cooled balloon surrounding the transducers. A theoretical evaluation of this design was performed by developing a 3D acoustic and bioheat transfer model, with temperature and thermal dose solutions obtained using a FEM solver (COMSOL Multiphysics). Parametric studies were performed on a generalized anatomical model of the pancreas, tumor, and adjacent luminal wall to determine preferred transducer configurations and frequencies for maximizing lesion volume and penetration while sparing the luminal wall. Patient-specific models of pancreatic tumors were generated from CT studies and used to assess the feasibility of performing thermal ablation or hyperthermia on small (˜2 cm diameter) pancreatic head tumors with an endoluminal applicator positioned within the duodenum. Simulation results indicate lower transducer operating frequencies (1-3 MHz) are necessary to mitigate damage to the luminal wall, and a tradeoff between penetration depth and lesion volume emerges as the degree of focusing increases. For patient-specific ablation modeling of tumors within 30 mm of the luminal wall, approximately 95% of the volume could be ablated within 15 min using a planar or lightly focused transducer configuration without duodenal damage. Over 90% of the volume could be elevated above 40°C at steady state for hyperthermia applications (e.g., radiation sensitization, drug delivery) using a tubular transducer. For tumors extending deeper into the pancreas (˜35 mm), strongly focused curvilinear transducers could ablate over 80% of the tumor volume within 15 min while minimizing damage to nearby sensitive structures.

  3. Challenges in Accommodating Volume Change of Si Anodes for Li-Ion Batteries

    PubMed Central

    Ko, Minseong; Chae, Sujong; Cho, Jaephil

    2015-01-01

    Si has been considered as a promising alternative anode for next-generation Li-ion batteries (LIBs) because of its high theoretical energy density, relatively low working potential, and abundance in nature. However, Si anodes exhibit rapid capacity decay and an increase in the internal resistance, which are caused by the large volume changes upon Li insertion and extraction. This unfortunately limits their practical applications. Therefore, managing the total volume change remains a critical challenge for effectively alleviating the mechanical fractures and instability of solid-electrolyte-interphase products. In this regard, we review the recent progress in volume-change-accommodating Si electrodes and investigate their ingenious structures with significant improvements in the battery performance, including size-controlled materials, patterned thin films, porous structures, shape-preserving shell designs, and graphene composites. These representative approaches potentially overcome the large morphologic changes in the volume of Si anodes by securing the strain relaxation and structural integrity in the entire electrode. Finally, we propose perspectives and future challenges to realize the practical application of Si anodes in LIB systems. PMID:27525208

  4. The effect of intraocular gas and fluid volumes on intraocular pressure.

    PubMed

    Simone, J N; Whitacre, M M

    1990-02-01

    Large increases in the intraocular pressure (IOP) of postoperative gas-containing eyes may require the removal of gas or fluid to reduce the IOP to the normal range. Application of the ideal gas law to Friedenwald's equation provides a mathematical model of the relationship between IOP, intraocular gas and fluid volumes, and the coefficient of scleral rigidity. This mathematic model shows that removal of a given volume of gas or fluid produces an identical decrease in IOP and that the more gas an eye contains, the greater the volume reduction necessary to reduce the pressure. Application of the model shows that the effective coefficient of scleral rigidity is low (mean K, 0.0021) in eyes with elevated IOP that have undergone vitrectomy and retinal cryopexy and very low (mean K, 0.0013) in eyes with elevated IOP that have undergone placement of a scleral buckle and band. By using the appropriate mean coefficient of rigidity, the volume of material to be aspirated to produce a given decrease in IOP can be predicted with clinically useful accuracy.

  5. Proceedings of a Workshop on the Applications of Tethers in Space, Volume 1

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Project overview; tether deployment; satellite system description; tether fundamentals; science applications; electrodynamic interactions; transportation; artificial gravity; and constellations; were described.

  6. Hierarchical Theoretical Methods for Understanding and Predicting Anisotropic Thermal Transport Release in Rocket Propellant Formulations

    DTIC Science & Technology

    2016-12-08

    mesoscopic models of interfaces and interphases, and microstructure-resolved representative volume element simulations. Atomic simulations were...title and subtitle with volume number and part number, if applicable. On classified documents, enter the title classification in parentheses. 5a...careful prediction of the pressure- volume -temperature equation of state, pressure- and temperature-dependent crystal and liquid thermal and transport

  7. Advances in threat assessment and their application to forest and rangeland management—Volume 1 and Volume 2.

    Treesearch

    John M. Pye; H. Michael Rauscher; Yasmeen Sands; Danny C. Lee; Jerome S. Beatty

    2010-01-01

    In July 2006, more than 170 researchers and managers from the United States, Canada, and Mexico convened in Boulder, Colorado, to discuss the state of the science in environmental threat assessment. This two-volume general technical report compiles peer-reviewed papers that were among those presented during the 3-day conference. Papers are organized by four broad...

  8. Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy

    NASA Astrophysics Data System (ADS)

    Flach, Barbara; Brehm, Marcus; Sawall, Stefan; Kachelrieß, Marc

    2014-12-01

    Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be applied. But research in temporal-correlated image reconstruction and dose reductions increases the number of cases where rawdata are available from only few projection angles. Here, deteriorated image quality leads to non-acceptable deformable volume-to-volume registration results. Therefore a registration approach is required that is robust against a decreasing number of projections defining the target position. We propose a deformable volume-to-rawdata (3D-2D) registration method that aims at finding a displacement vector field maximizing the alignment of a CT volume and the acquired rawdata based on the sum of squared differences in rawdata domain. The registration is constrained by a regularization term in accordance with a fluid-based diffusion. Both cost function components, the rawdata fidelity and the regularization term, are optimized in an alternating manner. The matching criterion is optimized by a conjugate gradient descent for nonlinear functions, while the regularization is realized by convolution of the vector fields with Gaussian kernels. We validate the proposed method and compare it to the demons algorithm, a well-known 3D-3D registration method. The comparison is done for a range of 4-60 target projections using datasets from low dose tomographic fluoroscopy as an application example. The results show a high correlation to the ground truth target position without introducing artifacts even in the case of very few projections. In particular the matching in the rawdata domain is improved compared to the 3D-3D registration for the investigated range. The proposed volume-to-rawdata registration increases the robustness regarding sparse rawdata and provides more stable results than volume-to-volume approaches. By applying the proposed registration approach to low dose tomographic fluoroscopy it is possible to improve the temporal resolution and thus to increase the robustness of low dose tomographic fluoroscopy.

  9. High internal free volume compositions for low-k dielectric and other applications

    NASA Technical Reports Server (NTRS)

    Bouffard, Jean (Inventor); Swager, Timothy M. (Inventor)

    2010-01-01

    The present invention provides materials, devices, and methods involving new heterocyclic, shape-persistent monomeric units with internal free volume. In some cases, materials the present invention may comprise monomers, oligomers, or polymers that incorporate a heterocyclic, shape-persistent iptycene. The present invention may provide materials having low dielectric constants and improved stability at high operating temperatures due to the electron-poor character of materials. In addition, compositions of the invention may be easily synthesized and readily modified to suit a particular application.

  10. The application of finite volume methods for modelling three-dimensional incompressible flow on an unstructured mesh

    NASA Astrophysics Data System (ADS)

    Lonsdale, R. D.; Webster, R.

    This paper demonstrates the application of a simple finite volume approach to a finite element mesh, combining the economy of the former with the geometrical flexibility of the latter. The procedure is used to model a three-dimensional flow on a mesh of linear eight-node brick (hexahedra). Simulations are performed for a wide range of flow problems, some in excess of 94,000 nodes. The resulting computer code ASTEC that incorporates these procedures is described.

  11. Transonic Symposium: Theory, Application, and Experiment, volume 1, part 2

    NASA Technical Reports Server (NTRS)

    Foughner, Jerome T., Jr. (Compiler)

    1989-01-01

    In order to assess the state of the art in transonic flow disciplines and to glimpse at future directions, NASA-Langley held a Transonic Symposium. Emphasis was placed on steady, three dimensional external, transonic flow and its simulation, both numerically and experimentally. The symposium included technical sessions on wind tunnel and flight experiments; computational fluid dynamic applications; inviscid methods and grid generation; viscous methods and boundary layer stability; and wind tunnel techniques and wall interference. This, being volume 1, is unclassified.

  12. Laser Setup for Volume Diffractive Optical Elements Recording in Photo-Thermo-Refractive Glass

    DTIC Science & Technology

    2016-04-14

    material and an optical glass . PTR glass is a Na2O-ZnO-Al2O3- SiO2 glass doped with silver (Ag), cerium (Ce), and fluorine (F). It is transparent from...SECURITY CLASSIFICATION OF: Recorded in photo-thermo-refractive (PTR) glass volume Bragg gratings (VBGs) have found great applications for...power laser applications, is restrained because of absence of available lasers emitting on PTR glass photosensitivity region (300-350 nm) with large

  13. Research and Advanced Development. Volume I - Supporting Research and Technology for the Office of Space Sciences and Applications, National Aeronautics and Space Administration Semiannual Review, 1 Jan. - 30 Jun. 1968.

    NASA Technical Reports Server (NTRS)

    1965-01-01

    This volume contains a review of all supporting research and technology in progress at the Jet Propulsion Laboratory during the period January 1 to June 30, 1965, under direction of the Office of Research and Advanced Development for the Office of Space Sciences and Applications. The work units are arranged in numerical sequence by NASA code in each subject section.

  14. NASA Non-Flow-Through PEM Fuel Cell System for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Araghi, Koorosh R.

    2011-01-01

    NASA is researching passive NFT Proton Exchange Membrane (PEM) fuel cell technologies for primary fuel cell power plants in air-independent applications. NFT fuel cell power systems have a higher power density than flow through systems due to both reduced parasitic loads and lower system mass and volume. Reactant storage still dominates system mass/volume considerations. NFT fuel cell stack testing has demonstrated equivalent short term performance to flow through stacks. More testing is required to evaluate long-term performance.

  15. Phytoremediation and innovative strategies for specialized remedial applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alleman, B.C.; Leeson, A.

    1999-10-01

    Phytoremediation is a site remediation strategy whose time seems to have come in the past few years, with field implementations taking place in a host of applications. From laboratory studies on plant uptake to full-scale phytoremediation treatment strategies, this volume covers the use of plants to treat contaminants such as hydrocarbons, metals, pesticides, perchlorate, and chlorinated solvents. In addition to the phytoremediation studies, this volume also covers specialized remediation approaches such as sequential anaerobic/aerobic in situ treatment, membrane bioreactors, and Fenton`s reagent oxidation.

  16. Update of vehicle sanction laws and their application : volume I and volume II.

    DOT National Transportation Integrated Search

    2008-09-01

    Because of the substantial number of driving while intoxicated (DWI) offenders driving illegally with suspended : licenses and the limited enforcement resources available to dealwith the problem, many States and the Federal government : have begun to...

  17. Automation Applications in an Advanced Air Traffic Management System : Volume 4A. Automation Requirements.

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 4 describes the automation requirements. A presentation of automation requirements is made for an advanced air traffic management system in terms of controller work force, computer resources, controller productivity, system manning, failure ef...

  18. Run-Off-Road Collision Avoidance Countermeasures Using IVHS Countermeasures, Task 1, Volume 2: Support Volume, Final Report

    DOT National Transportation Integrated Search

    1994-10-01

    THE RUN-OFF-ROAD COLLISION AVOIDANCE USING LVHS COUNTERMEASURES PROGRAM IS TO ADDRESS THE SINGLE VEHICLE CRASH PROBLEM THROUGH APPLICATION OF TECHNOLOGY TO PREVENT AND/OR REDUCE THE SEVERITY OF THESE CRASHES.

  19. Wayside Energy Storage Study : Volume 2. Detailed Description of Analysis.

    DOT National Transportation Integrated Search

    1979-02-01

    Volume II summarizes an in-depth application study which was conducted to determine the practicality and viability of using large wayside flywheels to recuperate braking energy from freight trains on long downgrades. The study examined the route stru...

  20. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 1. Summary.

    DOT National Transportation Integrated Search

    1977-11-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  1. Calibration of an electronic counter and pulse height analyzer for plotting erythrocyte volume spectra.

    DOT National Transportation Integrated Search

    1963-03-01

    A simple technique is presented for calibrating an electronic system used in the plotting of erythrocyte volume spectra. The calibration factors, once obtained, apparently remain applicable for some time. Precise estimates of calibration factors appe...

  2. Modern Chemical Technology, Volume 5.

    ERIC Educational Resources Information Center

    Pecsok, Robert L., Ed.; Chapman, Kenneth, Ed.

    This volume contains chapters 26-31 for the American Chemical Society (ACS) "Modern Chemical Technology" (ChemTeC) instructional material intended to prepare chemical technologists. Chapter 26 reviews oxidation and reduction, including applications in titrations with potassium permanganate and iodometry. Coordination compounds are…

  3. 9th Annual Systems Engineering Conference: Volume 4 Thursday

    DTIC Science & Technology

    2006-10-26

    Connectivity, Speed, Volume • Enterprise application integration • Workflow integration or multi-media • Federated search capability • Link analysis and...categorization, federated search & automated discovery of information — Collaborative tools to quickly share relevant information Built on commercial

  4. Engineering Data Compendium. Human Perception and Performance, Volume 1

    NASA Technical Reports Server (NTRS)

    Boff, Kenneth R. (Editor); Lincoln, Janet E. (Editor)

    1988-01-01

    The concept underlying the Engineering Data Compendium was the product an R and D program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design of military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by system designers. The present four volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is Volume 1, which contains sections on Visual Acquisition of Information, Auditory Acquisition of Information, and Acquisition of Information by Other Senses.

  5. An application specific integrated circuit based multi-anode microchannel array readout system

    NASA Technical Reports Server (NTRS)

    Smeins, Larry G.; Stechman, John M.; Cole, Edward H.

    1991-01-01

    Size reduction of two new multi-anode microchannel array (MAMA) readout systems is described. The systems are based on two analog and one digital application specific integrated circuits (ASICs). The new readout systems reduce volume over previous discrete designs by 80 percent while improving electrical performance on virtually every significant parameter. Emphasis is made on the packaging used to achieve the volume reduction. Surface mount technology (SMT) is combined with modular construction for the analog portion of the readout. SMT reliability concerns and the board area impact of MIL SPEC SMT components is addressed. Package selection for the analog ASIC is discussed. Future sytems will require even denser packaging and the volume reduction progression is shown.

  6. Engineering Data Compendium. Human Perception and Performance, Volume 2

    NASA Technical Reports Server (NTRS)

    Boff, Kenneth R. (Editor); Lincoln, Janet E. (Editor)

    1988-01-01

    The concept underlying the Engineering Data Compendium was the product of a Research and Development program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design of military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by system designers. The present volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is Volume 2, which contains sections on Information Storage and Retrieval, Spatial Awareness, Perceptual Organization, and Attention and Allocation of Resources.

  7. The application of capillary microsampling in GLP toxicology studies.

    PubMed

    Verhaeghe, Tom; Dillen, Lieve; Stieltjes, Hans; Zwart, Loeckie de; Feyen, Bianca; Diels, Luc; Vroman, Ann; Timmerman, Philip

    2017-04-01

    Capillary microsampling (CMS) to collect microplasma volumes is gradually replacing traditional, larger volume sampling from rats in GLP toxicology studies. About 32 µl of blood is collected with a capillary, processed to plasma and stored in a 10- or 4-µl capillary which is washed out further downstream in the laboratory. CMS has been standardized with respect to materials, assay validation experiments and application for sample analysis. The implementation of CMS has resulted in blood volume reductions in the rat from 300 to 32 µl per time point and the elimination of toxicokinetic satellite groups in the majority of the rat GLP toxicology studies. The technique has been successfully applied in 26 GLP studies for 12 different projects thus far.

  8. Characterization of volume holographic optical elements recorded in Bayfol HX photopolymer for solar photovoltaic applications.

    PubMed

    Marín-Sáez, Julia; Atencia, Jesús; Chemisana, Daniel; Collados, María-Victoria

    2016-03-21

    Volume Holographic Optical Elements (HOEs) present interesting characteristics for photovoltaic applications as they can select spectrum for concentrating the target bandwidth and avoiding non-desired wavelengths, which can cause the decrease of the performance on the cell, for instance by overheating it. Volume HOEs have been recorded on Bayfol HX photopolymer to test the suitability of this material for solar concentrating photovoltaic systems. The HOEs were recorded at 532 nm and provided a dynamic range, reaching close to 100% efficiency at 800 nm. The diffracted spectrum had a FWHM of 230 nm when illuminating at Bragg angle. These characteristics prove HOEs recorded on Bayfol HX photopolymer are suitable for concentrating solar light onto photovoltaic cells sensitive to that wavelength range.

  9. Engineering data compendium. Human perception and performance, volume 3

    NASA Technical Reports Server (NTRS)

    Boff, Kenneth R. (Editor); Lincoln, Janet E. (Editor)

    1988-01-01

    The concept underlying the Engineering Data Compendium was the product of a research and development program (Integrated Perceptual Information for Designers project) aimed at facilitating the application of basic research findings in human performance to the design of military crew systems. The principal objective was to develop a workable strategy for: (1) identifying and distilling information of potential value to system design from existing research literature, and (2) presenting this technical information in a way that would aid its accessibility, interpretability, and applicability by system designers. The present four volumes of the Engineering Data Compendium represent the first implementation of this strategy. This is Volume 3, containing sections on Human Language Processing, Operator Motion Control, Effects of Environmental Stressors, Display Interfaces, and Control Interfaces (Real/Virtual).

  10. Energy optimization of water and wastewater management for municipal and industrial applications conference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-08-01

    These proceedings document the presentations given at the Energy Optimization of Water and Wastewater Management for Municipal and Industrial Applications, Conference, sponsored by the Department of Energy (DOE). The conference was organized and coordinated by Argonne National Laboratory. The conference focused on energy use on conservation in water and wastewater. The General Session also reflects DOE's commitment to the support and development of waste and wastewater systems that are environmentally acceptable. The conference proceedings are divided into two volumes. Volume 1 contains the General Session and Sessions 1 to 5. Volume 2 covers Sessions 6 to 12. Separate abstracts aremore » prepared for each item within the scope of the Energy Data Base.« less

  11. Availability and temporal heterogeneity of water supply affect the vertical distribution and mortality of a belowground herbivore and consequently plant growth.

    PubMed

    Tsunoda, Tomonori; Kachi, Naoki; Suzuki, Jun-Ichirou

    2014-01-01

    We examined how the volume and temporal heterogeneity of water supply changed the vertical distribution and mortality of a belowground herbivore, and consequently affected plant biomass. Plantago lanceolata (Plantaginaceae) seedlings were grown at one per pot under different combinations of water volume (large or small volume) and heterogeneity (homogeneous water conditions, watered every day; heterogeneous conditions, watered every 4 days) in the presence or absence of a larva of the belowground herbivorous insect, Anomala cuprea (Coleoptera: Scarabaeidae). The larva was confined in different vertical distributions to top feeding zone (top treatment), middle feeding zone (middle treatment), or bottom feeding zone (bottom treatment); alternatively no larva was introduced (control treatment) or larval movement was not confined (free treatment). Three-way interaction between water volume, heterogeneity, and the herbivore significantly affected plant biomass. With a large water volume, plant biomass was lower in free treatment than in control treatment regardless of heterogeneity. Plant biomass in free treatment was as low as in top treatment. With a small water volume and in free treatment, plant biomass was low (similar to that under top treatment) under homogeneous water conditions but high under heterogeneous ones (similar to that under middle or bottom treatment). Therefore, there was little effect of belowground herbivory on plant growth under heterogeneous water conditions. In other watering regimes, herbivores would be distributed in the shallow soil and reduced root biomass. Herbivore mortality was high with homogeneous application of a large volume or heterogeneous application of a small water volume. Under the large water volume, plant biomass was high in pots in which the herbivore had died. Thus, the combinations of water volume and heterogeneity affected plant growth via the change of a belowground herbivore.

  12. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  13. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  14. 49 CFR 545.3 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE THEFT PREVENTION STANDARD PHASE-IN AND SMALL-VOLUME LINE REPORTING REQUIREMENTS § 545.3 Applicability. This subpart applies to manufacturers of motor vehicles. ...

  15. Feasibility of single-beat full-volume capture real-time three-dimensional echocardiography and auto-contouring algorithm for quantification of left ventricular volume: validation with cardiac magnetic resonance imaging.

    PubMed

    Chang, Sung-A; Lee, Sang-Chol; Kim, Eun-Young; Hahm, Seung-Hee; Jang, Shin Yi; Park, Sung-Ji; Choi, Jin-Oh; Park, Seung Woo; Choe, Yeon Hyeon; Oh, Jae K

    2011-08-01

    With recent developments in echocardiographic technology, a new system using real-time three-dimensional echocardiography (RT3DE) that allows single-beat acquisition of the entire volume of the left ventricle and incorporates algorithms for automated border detection has been introduced. Provided that these techniques are acceptably reliable, three-dimensional echocardiography may be much more useful for clinical practice. The aim of this study was to evaluate the feasibility and accuracy of left ventricular (LV) volume measurements by RT3DE using the single-beat full-volume capture technique. One hundred nine consecutive patients scheduled for cardiac magnetic resonance imaging and RT3DE using the single-beat full-volume capture technique on the same day were recruited. LV end-systolic volume, end-diastolic volume, and ejection fraction were measured using an auto-contouring algorithm from data acquired on RT3DE. The data were compared with the same measurements obtained using cardiac magnetic resonance imaging. Volume measurements on RT3DE with single-beat full-volume capture were feasible in 84% of patients. Both interobserver and intraobserver variability of three-dimensional measurements of end-systolic and end-diastolic volumes showed excellent agreement. Pearson's correlation analysis showed a close correlation of end-systolic and end-diastolic volumes between RT3DE and cardiac magnetic resonance imaging (r = 0.94 and r = 0.91, respectively, P < .0001 for both). Bland-Altman analysis showed reasonable limits of agreement. After application of the auto-contouring algorithm, the rate of successful auto-contouring (cases requiring minimal manual corrections) was <50%. RT3DE using single-beat full-volume capture is an easy and reliable technique to assess LV volume and systolic function in clinical practice. However, the image quality and low frame rate still limit its application for dilated left ventricles, and the automated volume analysis program needs more development to make it clinically efficacious. Copyright © 2011 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  16. Surfactants as blackbird stressing agents

    USGS Publications Warehouse

    Lefebvre, P.W.; Seubert, J.L.

    1970-01-01

    Applications of wetting-agent solutions produce mortality in birds. The exact cause of death is undetermined but it is believed that destruction of the insulating qualities of the plumage permits ambient cold temperatures and evaporation to lower the body temperature to a lethal level. The original concept of using these materials as bird-control tools was developed in 1958 at the Patuxent Wildlife Research Center, Bureau of Sport Fisheries and Wildlife Laurel, Maryland. Early field trials by personnel of the Division of Wildlife Services and the Denver Wildlife Research Center indicated that ground-application techniques had promise but limitations of the equipment precluded successful large-scale roost treatments. In 1966, Patuxent Center personnel began using tanker-type aircraft to evaluate high-volume aerial applications of wetting agents. The success of these tests led to the use of small aircraft to make low-volume, high-concentration aerial applications just prior to expected rainfall. Recent trials of the low-volume method show that, with some limitations, it is effective, inexpensive, and safe to the environment. Current research emphasizes the screening of new candidate materials for efficacy, biodegradability, and toxicity to plants and non-target animals, as well as basic investigations of the avian physiological mechanisms involved. Field trials to develop more effective application techniques will continue.

  17. Less and less–influence of volume on hand coverage and bactericidal efficacy in hand disinfection

    PubMed Central

    2013-01-01

    Background Some manufacturers recommend using 1.1 mL per application of alcohol-based handrubs for effective hand disinfection. However, whether this volume is sufficient to cover both hands, as recommended by the World Health Organization, and fulfills current efficacy standards is unknown. This study aimed to determine hand coverage for three handrubs (two gels based on 70% v/v and 85% w/w ethanol and a foam based on 70% v/v ethanol) applied at various volumes. Methods Products were tested at product volumes of 1.1 mL, 2 mL, 2.4 mL as well as 1 and 2 pump dispenser pushes; the foam product was tested in addition at foam volumes of 1.1 mL, 2 mL, and 2.4 mL. Products were supplemented with a fluorescent dye and 15 participants applied products using responsible application techniques without any specific steps but the aim of completely covering both hands. Coverage quality was determined under ultraviolet light by two blinded investigators. Efficacy of the three handrubs was determined according to ASTM E 1174-06 and ASTM E 2755-10. For each experiment, the hands of 12 participants were contaminated with Serratia marcescens and the products applied as recommended (1.1 mL for 70% v/v ethanol products; 2 mL for the 85% w/w ethanol product). Log10-reduction was calculated. Results Volumes < 2 mL yielded high rates of incomplete coverage (67%–87%) whereas volumes ≥ 2 mL gave lower rates (13%–53%). Differences in coverage were significant between the five volumes tested for all handrubs (p < 0.001; two-way ANOVA) but not between the three handrubs themselves (p = 0.796). Application of 1.1 mL of 70% v/v ethanol rubs reduced contamination by 1.85 log10 or 1.60 log10 (ASTM E 1174-06); this failed the US FDA efficacy requirement of at least 2 log10. Application of 2 mL of the 85% w/w ethanol rub reduced contamination by 2.06 log10 (ASTM E 1174-06), fulfilling the US FDA efficacy requirement. Similar results were obtained according to ASTM E 2755-10. Conclusions Our data indicated that handrubs based on 70% ethanol (v/v) with a recommended volume of 1.1 mL per application do not ensure complete coverage of both hands and do not achieve current ASTM efficacy standards. PMID:24112994

  18. GPU-based multi-volume ray casting within VTK for medical applications.

    PubMed

    Bozorgi, Mohammadmehdi; Lindseth, Frank

    2015-03-01

    Multi-volume visualization is important for displaying relevant information in multimodal or multitemporal medical imaging studies. The main objective with the current study was to develop an efficient GPU-based multi-volume ray caster (MVRC) and validate the proposed visualization system in the context of image-guided surgical navigation. Ray casting can produce high-quality 2D images from 3D volume data but the method is computationally demanding, especially when multiple volumes are involved, so a parallel GPU version has been implemented. In the proposed MVRC, imaginary rays are sent through the volumes (one ray for each pixel in the view), and at equal and short intervals along the rays, samples are collected from each volume. Samples from all the volumes are composited using front to back α-blending. Since all the rays can be processed simultaneously, the MVRC was implemented in parallel on the GPU to achieve acceptable interactive frame rates. The method is fully integrated within the visualization toolkit (VTK) pipeline with the ability to apply different operations (e.g., transformations, clipping, and cropping) on each volume separately. The implemented method is cross-platform (Windows, Linux and Mac OSX) and runs on different graphics card (NVidia and AMD). The speed of the MVRC was tested with one to five volumes of varying sizes: 128(3), 256(3), and 512(3). A Tesla C2070 GPU was used, and the output image size was 600 × 600 pixels. The original VTK single-volume ray caster and the MVRC were compared when rendering only one volume. The multi-volume rendering system achieved an interactive frame rate (> 15 fps) when rendering five small volumes (128 (3) voxels), four medium-sized volumes (256(3) voxels), and two large volumes (512(3) voxels). When rendering single volumes, the frame rate of the MVRC was comparable to the original VTK ray caster for small and medium-sized datasets but was approximately 3 frames per second slower for large datasets. The MVRC was successfully integrated in an existing surgical navigation system and was shown to be clinically useful during an ultrasound-guided neurosurgical tumor resection. A GPU-based MVRC for VTK is a useful tool in medical visualization. The proposed multi-volume GPU-based ray caster for VTK provided high-quality images at reasonable frame rates. The MVRC was effective when used in a neurosurgical navigation application.

  19. Collective phenomena in volume and surface barrier discharges

    NASA Astrophysics Data System (ADS)

    Kogelschatz, U.

    2010-11-01

    Barrier discharges are increasingly used as a cost-effective configuration to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without significant heating of the background gas. In most applications the barrier is made of dielectric material. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are devoted to biomedical applications and to plasma actuators for flow control. Sinusoidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or diffuse, laterally homogeneous discharges. The physical effects leading to collective phenomena in volume and surface barrier discharges are discussed in detail. Special attention is paid to self-organization of current filaments and pattern formation. Major similarities of the two types of barrier discharges are elaborated.

  20. Automation Applications in an Advanced Air Traffic Management System : Volume 4B. Automation Requirements (Concluded)

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 4 describes the automation requirements. A presentation of automation requirements is made for an advanced air traffic management system in terms of controller work for-e, computer resources, controller productivity, system manning, failure ef...

  1. Modeling of hot-mix asphalt compaction : a thermodynamics-based compressible viscoelastic model

    DOT National Transportation Integrated Search

    2010-12-01

    Compaction is the process of reducing the volume of hot-mix asphalt (HMA) by the application of external forces. As a result of compaction, the volume of air voids decreases, aggregate interlock increases, and interparticle friction increases. The qu...

  2. 40 CFR 440.143 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... which may be discharged from an open-cut mine plant site shall not exceed the volume of infiltration... site shall not exceed the volume of infiltration, drainage and mine drainage waters which is in excess...

  3. 40 CFR 440.143 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... which may be discharged from an open-cut mine plant site shall not exceed the volume of infiltration... site shall not exceed the volume of infiltration, drainage and mine drainage waters which is in excess...

  4. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 3. Sections 5 through 9.

    DOT National Transportation Integrated Search

    1977-11-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  5. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 2. Sections 1 through 4.

    DOT National Transportation Integrated Search

    1977-01-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  6. Volumetric measurement of tank volume

    NASA Technical Reports Server (NTRS)

    Walter, Richard T. (Inventor); Vanbuskirk, Paul D. (Inventor); Weber, William F. (Inventor); Froebel, Richard C. (Inventor)

    1991-01-01

    A method is disclosed for determining the volume of compressible gas in a system including incompressible substances in a zero-gravity environment consisting of measuring the change in pressure (delta P) for a known volume change rate (delta V/delta t) in the polytrophic region between isothermal and adiabatic conditions. The measurements are utilized in an idealized formula for determining the change in isothermal pressure (delta P sub iso) for the gas. From the isothermal pressure change (delta iso) the gas volume is obtained. The method is also applicable to determination of gas volume by utilizing work (W) in the compression process. In a passive system, the relationship of specific densities can be obtained.

  7. Volume Fraction Determination in Cast Superalloys and DS Eutectic Alloys by a New Practice for Manual Point Counting

    NASA Technical Reports Server (NTRS)

    Andrews, C. W.

    1976-01-01

    Volume fraction of a constituent or phase was estimated in six specimens of conventional and DS-eutectic superalloys, using ASTM E562-76, a new standard recommended practice for determining volume fraction by systematic manual point count. Volume fractions determined ranged from 0.086 to 0.36, and with one exception, the 95 percent relative confidence limits were approximately 10 percent of the determined volume fractions. Since the confidence-limit goal of 10 percent, which had been arbitrarily chosen previously, was achieved in all but one case, this application of the new practice was considered successful.

  8. A flexible and accurate digital volume correlation method applicable to high-resolution volumetric images

    NASA Astrophysics Data System (ADS)

    Pan, Bing; Wang, Bo

    2017-10-01

    Digital volume correlation (DVC) is a powerful technique for quantifying interior deformation within solid opaque materials and biological tissues. In the last two decades, great efforts have been made to improve the accuracy and efficiency of the DVC algorithm. However, there is still a lack of a flexible, robust and accurate version that can be efficiently implemented in personal computers with limited RAM. This paper proposes an advanced DVC method that can realize accurate full-field internal deformation measurement applicable to high-resolution volume images with up to billions of voxels. Specifically, a novel layer-wise reliability-guided displacement tracking strategy combined with dynamic data management is presented to guide the DVC computation from slice to slice. The displacements at specified calculation points in each layer are computed using the advanced 3D inverse-compositional Gauss-Newton algorithm with the complete initial guess of the deformation vector accurately predicted from the computed calculation points. Since only limited slices of interest in the reference and deformed volume images rather than the whole volume images are required, the DVC calculation can thus be efficiently implemented on personal computers. The flexibility, accuracy and efficiency of the presented DVC approach are demonstrated by analyzing computer-simulated and experimentally obtained high-resolution volume images.

  9. The reciprocal iso-inhibition volume concept: A procedure for the evaluation in effect-directed analysis with thin-layer chromatography - using the thin-layer chromatography-luminescent bacteria assay as an example.

    PubMed

    Schulz, Wolfgang; Weiss, Stefan C; Weber, Walter H; Winzenbacher, Rudi

    2017-10-13

    In effect-directed analysis (EDA) with high-performance thin-layer chromatography (HPTLC), the effect is often detected using images. Thus, an approach to create inhibition chromatograms from these images was developed using the example of the HPTLC- bioluminescence inhibition test. A comparison between the cuvette test and the HPTLC test shows that the test on the plate is significantly more sensitive. To describe the strength of the effect, the EC 50 value is determined from the dose-response relationship. However, the inhibiting compounds are generally unknown and thus their concentrations are also unknown. Therefore, instead of the concentration, the known application volumes are used. This enables the calculation of the application volume necessary to achieve 50% inhibition. Since the volume is inversely proportional to the concentration, the reciprocal value of the calculated volume is indicated and is referred to as the reciprocal iso-inhibition volume (RIV). Using this RIV-concept, it is now possible to compare inhibition bands within and between plates. The entire evaluation is described by the means of two samples from a contaminated site using the bioluminescence inhibition. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Dry Volume Fracturing Simulation of Shale Gas Reservoir

    NASA Astrophysics Data System (ADS)

    Xu, Guixi; Wang, Shuzhong; Luo, Xiangrong; Jing, Zefeng

    2017-11-01

    Application of CO2 dry fracturing technology to shale gas reservoir development in China has advantages of no water consumption, little reservoir damage and promoting CH4 desorption. This paper uses Meyer simulation to study complex fracture network extension and the distribution characteristics of shale gas reservoirs in the CO2 dry volume fracturing process. The simulation results prove the validity of the modified CO2 dry fracturing fluid used in shale volume fracturing and provides a theoretical basis for the following study on interval optimization of the shale reservoir dry volume fracturing.

  11. Finite-volume scheme for anisotropic diffusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Es, Bram van, E-mail: bramiozo@gmail.com; FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, The Netherlands"1; Koren, Barry

    In this paper, we apply a special finite-volume scheme, limited to smooth temperature distributions and Cartesian grids, to test the importance of connectivity of the finite volumes. The area of application is nuclear fusion plasma with field line aligned temperature gradients and extreme anisotropy. We apply the scheme to the anisotropic heat-conduction equation, and compare its results with those of existing finite-volume schemes for anisotropic diffusion. Also, we introduce a general model adaptation of the steady diffusion equation for extremely anisotropic diffusion problems with closed field lines.

  12. Large-Scale High-Resolution Cylinder Wake Measurements in a Wind Tunnel using Tomographic PIV with sCMOS Cameras

    NASA Astrophysics Data System (ADS)

    Michaelis, Dirk; Schroeder, Andreas

    2012-11-01

    Tomographic PIV has triggered vivid activity, reflected in a large number of publications, covering both: development of the technique and a wide range of fluid dynamic experiments. Maturing of tomo PIV allows the application in medium to large scale wind tunnels. Limiting factor for wind tunnel application is the small size of the measurement volume, being typically about of 50 × 50 × 15 mm3. Aim of this study is the optimization towards large measurement volumes and high spatial resolution performing cylinder wake measurements in a 1 meter wind tunnel. Main limiting factors for the volume size are the laser power and the camera sensitivity. So, a high power laser with 800 mJ per pulse is used together with low noise sCMOS cameras, mounted in forward scattering direction to gain intensity due to the Mie scattering characteristics. A mirror is used to bounce the light back, to have all cameras in forward scattering. Achievable particle density is growing with number of cameras, so eight cameras are used for a high spatial resolution. Optimizations lead to volume size of 230 × 200 × 52 mm3 = 2392 cm3, more than 60 times larger than previously. 281 × 323 × 68 vectors are calculated with spacing of 0.76 mm. The achieved measurement volume size and spatial resolution is regarded as a major step forward in the application of tomo PIV in wind tunnels. Supported by EU-project: no. 265695.

  13. Volume determination of irregularly-shaped quasi-spherical nanoparticles.

    PubMed

    Attota, Ravi Kiran; Liu, Eileen Cherry

    2016-11-01

    Nanoparticles (NPs) are widely used in diverse application areas, such as medicine, engineering, and cosmetics. The size (or volume) of NPs is one of the most important parameters for their successful application. It is relatively straightforward to determine the volume of regular NPs such as spheres and cubes from a one-dimensional or two-dimensional measurement. However, due to the three-dimensional nature of NPs, it is challenging to determine the proper physical size of many types of regularly and irregularly-shaped quasi-spherical NPs at high-throughput using a single tool. Here, we present a relatively simple method that determines a better volume estimate of NPs by combining measurements from their top-down projection areas and peak heights using two tools. The proposed method is significantly faster and more economical than the electron tomography method. We demonstrate the improved accuracy of the combined method over scanning electron microscopy (SEM) or atomic force microscopy (AFM) alone by using modeling, simulations, and measurements. This study also exposes the existence of inherent measurement biases for both SEM and AFM, which usually produce larger measured diameters with SEM than with AFM. However, in some cases SEM measured diameters appear to have less error compared to AFM measured diameters, especially for widely used IS-NPs such as of gold, and silver. The method provides a much needed, proper high-throughput volumetric measurement method useful for many applications. Graphical Abstract The combined method for volume determination of irregularly-shaped quasi-spherical nanoparticles.

  14. Investigation Of The Effects Of Reflow Profile Parameters On Lead-free Solder Bump Volumes And Joint Integrity

    NASA Astrophysics Data System (ADS)

    Amalu, E. H.; Lui, Y. T.; Ekere, N. N.; Bhatti, R. S.; Takyi, G.

    2011-01-01

    The electronics manufacturing industry was quick to adopt and use the Surface Mount Technology (SMT) assembly technique on realization of its huge potentials in achieving smaller, lighter and low cost product implementations. Increasing global customer demand for miniaturized electronic products is a key driver in the design, development and wide application of high-density area array package format. Electronic components and their associated solder joints have reduced in size as the miniaturization trend in packaging continues to be challenged by printing through very small stencil apertures required for fine pitch flip-chip applications. At very narrow aperture sizes, solder paste rheology becomes crucial for consistent paste withdrawal. The deposition of consistent volume of solder from pad-to-pad is fundamental to minimizing surface mount assembly defects. This study investigates the relationship between volume of solder paste deposit (VSPD) and the volume of solder bump formed (VSBF) after reflow, and the effect of reflow profile parameters on lead-free solder bump formation and the associated solder joint integrity. The study uses a fractional factorial design (FFD) of 24-1 Ramp-Soak-Spike reflow profile, with all main effects and two-way interactions estimable to determine the optimal factorial combination. The results from the study show that the percentage change in the VSPD depends on the combination of the process parameters and reliability issues could become critical as the size of solder joints soldered on the same board assembly vary greatly. Mathematical models describe the relationships among VSPD, VSBF and theoretical volume of solder paste. Some factors have main effects across the volumes and a number of interactions exist among them. These results would be useful for R&D personnel in designing and implementing newer applications with finer-pitch interconnect.

  15. Membranes with artificial free-volume for biofuel production

    PubMed Central

    Petzetakis, Nikos; Doherty, Cara M.; Thornton, Aaron W.; Chen, X. Chelsea; Cotanda, Pepa; Hill, Anita J.; Balsara, Nitash P.

    2015-01-01

    Free-volume of polymers governs transport of penetrants through polymeric films. Control over free-volume is thus important for the development of better membranes for a wide variety of applications such as gas separations, pharmaceutical purifications and energy storage. To date, methodologies used to create materials with different amounts of free-volume are based primarily on chemical synthesis of new polymers. Here we report a simple methodology for generating free-volume based on the self-assembly of polyethylene-b-polydimethylsiloxane-b-polyethylene triblock copolymers. We have used this method to fabricate a series of membranes with identical compositions but with different amounts of free-volume. We use the term artificial free-volume to refer to the additional free-volume created by self-assembly. The effect of artificial free-volume on selective transport through the membranes was tested using butanol/water and ethanol/water mixtures due to their importance in biofuel production. We found that the introduction of artificial free-volume improves both alcohol permeability and selectivity. PMID:26104672

  16. Membranes with artificial free-volume for biofuel production

    NASA Astrophysics Data System (ADS)

    Petzetakis, Nikos; Doherty, Cara M.; Thornton, Aaron W.; Chen, X. Chelsea; Cotanda, Pepa; Hill, Anita J.; Balsara, Nitash P.

    2015-06-01

    Free-volume of polymers governs transport of penetrants through polymeric films. Control over free-volume is thus important for the development of better membranes for a wide variety of applications such as gas separations, pharmaceutical purifications and energy storage. To date, methodologies used to create materials with different amounts of free-volume are based primarily on chemical synthesis of new polymers. Here we report a simple methodology for generating free-volume based on the self-assembly of polyethylene-b-polydimethylsiloxane-b-polyethylene triblock copolymers. We have used this method to fabricate a series of membranes with identical compositions but with different amounts of free-volume. We use the term artificial free-volume to refer to the additional free-volume created by self-assembly. The effect of artificial free-volume on selective transport through the membranes was tested using butanol/water and ethanol/water mixtures due to their importance in biofuel production. We found that the introduction of artificial free-volume improves both alcohol permeability and selectivity.

  17. Membranes with artificial free-volume for biofuel production

    DOE PAGES

    Petzetakis, Nikos; Doherty, Cara M.; Thornton, Aaron W.; ...

    2015-06-24

    Free-volume of polymers governs transport of penetrants through polymeric films. Control over free-volume is thus important for the development of better membranes for a wide variety of applications such as gas separations, pharmaceutical purifications and energy storage. To date, methodologies used to create materials with different amounts of free-volume are based primarily on chemical synthesis of new polymers. Here we report a simple methodology for generating free-volume based on the self-assembly of polyethylene-b-polydimethylsiloxane-b-polyethylene triblock copolymers. Here, we have used this method to fabricate a series of membranes with identical compositions but with different amounts of free-volume. We use the termmore » artificial free-volume to refer to the additional free-volume created by self-assembly. The effect of artificial free-volume on selective transport through the membranes was tested using butanol/water and ethanol/water mixtures due to their importance in biofuel production. Moreover, we found that the introduction of artificial free-volume improves both alcohol permeability and selectivity.« less

  18. Greenhouse Evaluation of Air-Assist Delivery Parameters for Mature Poinsettias

    USDA-ARS?s Scientific Manuscript database

    Understanding the performance characteristics of application equipment is important for helping make the most efficacious applications. While handguns making high volume applications are common in greenhouse production, it is difficult to achieve uniform distribution of product in a timely manner. ...

  19. Optimal application of the Contura multilumen balloon breast brachytherapy catheter vacuum port to deliver accelerated partial breast irradiation.

    PubMed

    Tokita, Kenneth M; Cuttino, Laurie W; Vicini, Frank A; Arthur, Douglas W; Todor, Dorin A; Julian, Thomas B; Lyden, Maureen R

    2011-01-01

    The impact of using the Contura multilumen balloon (MLB) (SenoRx, Inc., Irvine, CA) breast brachytherapy catheter's vacuum port in patients treated with accelerated partial breast irradiation (APBI) was analyzed. Data from 32 patients at two sites were reviewed. Variables analyzed included the seroma fluid (SF):air volume around the MLB before and after vacuum port use and on its ability to improve (1) the eligibility of patients for APBI and (2) dose coverage of the planning target volume for evaluation (PTV_EVAL) in eligible patients. The median SF/air volume before vacuum removal was 6.8 cc vs. 0.8 cc after vacuum removal (median reduction in SF/air volume was 90.5%). Before vacuum port use, the median SF/air volume expressed as percentage of the PTV_EVAL was 7.8% (range, 1.9-26.6) in all patients. After application of the vacuum, this was reduced to 1.2%. Before vacuum port use, 10 (31.3%) patients were not considered acceptable candidates for APBI because the SF/air volume:PTV_EVAL ratio (SF:PTV) was greater than 10% (range, 10.1-26.6%; median, 15.2%). After vacuum port use, the median SF:PTV ratio was 1.6% for a median reduction of 91.5%. In addition, the percentage of the prescribed dose covering greater than or equal to 90% of the PTV_EVAL proportionally increased a median of 8% (range, 3-10%) in eligible patients. Use of the Contura MLB vacuum port significantly improved the conformity of the target tissue to the balloon surface, leading to reproducible dose delivery and increased target volume coverage. In addition, application of the vacuum allowed the safe treatment of unacceptable patients with APBI. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Passive continuous positive airway pressure ventilation during cardiopulmonary resuscitation: a randomized cross-over manikin simulation study.

    PubMed

    Winkler, Bernd E; Muellenbach, Ralf M; Wurmb, Thomas; Struck, Manuel F; Roewer, Norbert; Kranke, Peter

    2017-02-01

    While controlled ventilation is most frequently used during cardiopulmonary resuscitation (CPR), the application of continuous positive airway pressure (CPAP) and passive ventilation of the lung synchronously with chest compressions and decompressions might represent a promising alternative approach. One benefit of CPAP during CPR is the reduction of peak airway pressures and therefore a potential enhancement in haemodynamics. We therefore evaluated the tidal volumes and airway pressures achieved during CPAP-CPR. During CPR with the LUCAS™ 2 compression device, a manikin model was passively ventilated at CPAP levels of 5, 10, 20 and 30 hPa with the Boussignac tracheal tube and the ventilators Evita ® V500, Medumat ® Transport, Oxylator ® EMX, Oxylog ® 2000, Oxylog ® 3000, Primus ® and Servo ® -i as well as the Wenoll ® diver rescue system. Tidal volumes and airway pressures during CPAP-CPR were recorded and analyzed. Tidal volumes during CPAP-CPR were higher than during compression-only CPR without positive airway pressure. The passively generated tidal volumes increased with increasing CPAP levels and were significantly influenced by the ventilators used. During ventilation at 20 hPa CPAP via a tracheal tube, the mean tidal volumes ranged from 125 ml (Medumat ® ) to 309 ml (Wenoll ® ) and the peak airway pressures from 23 hPa (Primus ® ) to 49 hPa (Oxylog ® 3000). Transport ventilators generated lower tidal volumes than intensive care ventilators or closed-circuit systems. Peak airway pressures during CPAP-CPR were lower than those during controlled ventilation CPR reported in literature. High peak airway pressures are known to limit the applicability of ventilation via facemask or via supraglottic airway devices and may adversely affect haemodynamics. Hence, the application of ventilators generating high tidal volumes with low peak airway pressures appears desirable during CPAP-CPR. The limited CPAP-CPR capabilities of transport ventilators in our study might be prerequisite for future developments of transport ventilators.

  1. Automation Applications in an Advanced Air Traffic Management System : Volume 5A. DELTA Simulation Model - User's Guide

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 4 describes the automation requirements. A presentation of automation requirements is made for an advanced air traffic management system in terms of controller work for-e, computer resources, controller productivity, system manning, failure ef...

  2. 40 CFR 721.537 - Organosilane ester.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the substance beyond the aggregate production volume limit, unless that person conducts this study on.... Scientific valid means that the study was conducted according to: (1) The test guidelines specified in... weeks prior to exceeding the applicable production volume limit. The final report shall contain the...

  3. Hybrid Vehicle Technology Constraints and Application Assessment Study : Volume 4. Sections 10, 11, and Appendix.

    DOT National Transportation Integrated Search

    1977-01-01

    This four-volume report presents analyses and assessments of both heat engine/battery- and heat engine/flywheel-powered hybrid vehicles to determine if they could contribute to near-term (1980-1990) reductions in transportation energy consumption und...

  4. 30 CFR 250.1203 - Gas measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... any changes to the previously-approved measurement and/or allocation procedures. Your application... and reflect the same degree of water saturation as in the gas volume. (8) When requested by the Regional Supervisor, submit copies of gas volume statements for each requested gas meter. Show whether gas...

  5. Exact solutions of a two parameter flux model and cryobiological applications.

    PubMed

    Benson, James D; Chicone, Carmen C; Critser, John K

    2005-06-01

    Solute-solvent transmembrane flux models are used throughout biological sciences with applications in plant biology, cryobiology (transplantation and transfusion medicine), as well as circulatory and kidney physiology. Using a standard two parameter differential equation model of solute and solvent transmembrane flux described by Jacobs [The simultaneous measurement of cell permeability to water and to dissolved substances, J. Cell. Comp. Physiol. 2 (1932) 427-444], we determine the functions that describe the intracellular water volume and moles of intracellular solute for every time t and every set of initial conditions. Here, we provide several novel biophysical applications of this theory to important biological problems. These include using this result to calculate the value of cell volume excursion maxima and minima along with the time at which they occur, a novel result that is of significant relevance to the addition and removal of permeating solutes during cryopreservation. We also present a methodology that produces extremely accurate sum of squares estimates when fitting data for cellular permeability parameter values. Finally, we show that this theory allows a significant increase in both accuracy and speed of finite element methods for multicellular volume simulations, which has critical clinical biophysical applications in cryosurgical approaches to cancer treatment.

  6. Hierarchically Porous Graphitic Carbon with Simultaneously High Surface Area and Colossal Pore Volume Engineered via Ice Templating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estevez, Luis; Prabhakaran, Venkateshkumar; Garcia, Adam L.

    Developing hierarchical porous carbon (HPC) materials with competing textural characteristics such as surface area and pore volume in one material is difficult to accomplish—particulalry for an atomically ordered (graphitic) carbon. Herein we describe a synthesis strategy to engineer tunable hierarchically porous carbon (HPC) materials across micro- meso- and macroporous length scales, allowing the fabrication of a graphitic HPC with both very high surface area (> 2500 m2/g) and pore volume (>10 cm3/g), the combination of which has not been seen previously. The mesopore volume alone for these materials is up to 7.91 cm3/g, the highest ever reported. The unique materialmore » was explored for use as a supercapaictor electrode and for oil adsorption; two applications that require textural properties that are typicaly exclusive to one another. This design scheme for HPCs can be utilized in broad applications, including electrochemical systems such as batteries and supercapacitors, sorbents, and catalyst supports.« less

  7. Preferred numbers and the distributions of trade sizes and trading volumes in the Chinese stock market

    NASA Astrophysics Data System (ADS)

    Mu, G.-H.; Chen, W.; Kertész, J.; Zhou, W.-X.

    2009-03-01

    The distributions of trade sizes and trading volumes are investigated based on the limit order book data of 22 liquid Chinese stocks listed on the Shenzhen Stock Exchange in the whole year 2003. We observe that the size distribution of trades for individualstocks exhibits jumps, which is caused by the number preference of traders when placing orders. We analyze the applicability of the “q-Gamma” function for fitting the distribution by the Cramér-von Mises criterion. The empirical PDFs of tradingvolumes at different timescales Δt ranging from 1 min to 240 min can be well modeled. The applicability of the q-Gamma functions for multiple trades is restricted to the transaction numbers Δn≤ 8. We find that all the PDFs have power-law tails for large volumes. Using careful estimation of the average tail exponents α of the distributions of trade sizes and trading volumes, we get α> 2, well outside the Lévy regime.

  8. Volumes of critical bubbles from the nucleation theorem

    NASA Astrophysics Data System (ADS)

    Wilemski, Gerald

    2006-09-01

    A corollary of the nucleation theorem due to Kashchiev [Nucleation: Basic Theory with Applications (Butterworth-Heinemann, Oxford, 2000)] allows the volume V* of a critical bubble to be determined from nucleation rate measurements. The original derivation was limited to one-component, ideal gas bubbles with a vapor density much smaller than that of the ambient liquid. Here, an exact result is found for multicomponent, nonideal gas bubbles. Provided a weak density inequality holds, this result reduces to Kashchiev's simple form which thus has a much broader range of applicability than originally expected. Limited applications to droplets are also mentioned, and the utility of the pT,x form of the nucleation theorem as a sum rule is noted.

  9. Sensors Applications, Volume 3, Sensors in Medicine and Health Care

    NASA Astrophysics Data System (ADS)

    Öberg, P. Åke; Togawa, Tatsuo; Spelman, Francis A.

    2004-08-01

    Taken as a whole, this series covers all major fields of application for commercial sensors, as well as their manufacturing techniques and major types. As such the series does not treat bulk sensors, but rather places strong emphasis on microsensors, microsystems and integrated electronic sensor packages. Each of the individual volumes is tailored to the needs and queries of readers from the relevant branch of industry. A review of applications for point-of-care diagnostics, their integration into portable systems and the comfortable, easy-to-use sensors that allow patients to monitor themselves at home. The book covers such advanced topics as minimal invasive surgery, implantable sensors and prostheses, as well as biocompatible sensing.

  10. Circuit compliance compensation in lung protective ventilation.

    PubMed

    Masselli, Grazia Maria Pia; Silvestri, Sergio; Sciuto, Salvatore Andrea; Cappa, Paolo

    2006-01-01

    Lung protective ventilation utilizes low tidal volumes to ventilate patients with severe lung pathologies. The compensation of breathing circuit effects, i.e. those induced by compressible volume of the circuit, results particularly critical in the calculation of the actual tidal volume delivered to patient's respiratory system which in turns is responsible of the level of permissive hypercapnia. The present work analyzes the applicability of the equation for circuit compressible volume compensation in the case of pressure and volume controlled lung protective ventilation. Experimental tests conducted in-vitro show that the actual tidal volume can be reliably estimated if the compliance of the breathing circuit is measured with the same parameters and ventilation technique that will be utilized in lung protective ventilation. Differences between volume and pressure controlled ventilation are also quantitatively assessed showing that pressure controlled ventilation allows a more reliable compensation of breathing circuit compressible volume.

  11. Chamber for the optical manipulation of microscopic particles

    DOEpatents

    Buican, Tudor N.; Upham, Bryan D.

    1992-01-01

    A particle control chamber enables experiments to be carried out on biological cells and the like using a laser system to trap and manipulate the particles. A manipulation chamber provides a plurality of inlet and outlet ports for the particles and for fluids used to control or to contact the particles. A central manipulation area is optically accessible by the laser and includes first enlarged volumes for containing a selected number of particles for experimentation. A number of first enlarged volumes are connected by flow channels through second enlarged volumes. The second enlarged volumes act as bubble valves for controlling the interconnections between the first enlarged volumes. Electrode surfaces may be applied above the first enlarged volumes to enable experimentation using the application of electric fields within the first enlarged volumes. A variety of chemical and environmental conditions may be established within individual first enlarged volumes to enable experimental conditions for small scale cellular interactions.

  12. Probability modeling of the number of positive cores in a prostate cancer biopsy session, with applications.

    PubMed

    Serfling, Robert; Ogola, Gerald

    2016-02-10

    Among men, prostate cancer (CaP) is the most common newly diagnosed cancer and the second leading cause of death from cancer. A major issue of very large scale is avoiding both over-treatment and under-treatment of CaP cases. The central challenge is deciding clinical significance or insignificance when the CaP biopsy results are positive but only marginally so. A related concern is deciding how to increase the number of biopsy cores for larger prostates. As a foundation for improved choice of number of cores and improved interpretation of biopsy results, we develop a probability model for the number of positive cores found in a biopsy, given the total number of cores, the volumes of the tumor nodules, and - very importantly - the prostate volume. Also, three applications are carried out: guidelines for the number of cores as a function of prostate volume, decision rules for insignificant versus significant CaP using number of positive cores, and, using prior distributions on total tumor size, Bayesian posterior probabilities for insignificant CaP and posterior median CaP. The model-based results have generality of application, take prostate volume into account, and provide attractive tradeoffs of specificity versus sensitivity. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Dielectric, thermal and mechanical properties of zirconium silicate reinforced high density polyethylene composites for antenna applications.

    PubMed

    Varghese, Jobin; Nair, Dinesh Raghavan; Mohanan, Pezholil; Sebastian, Mailadil Thomas

    2015-06-14

    A low cost and low dielectric loss zirconium silicate (ZrSiO4) reinforced HDPE (high-density polyethylene) composite has been developed for antenna applications. The 0-3 type composite is prepared by dispersing ZrSiO4 fillers for various volume fractions (0.1 to 0.5) in the HDPE matrix by the melt mixing process. The composite shows good microwave dielectric properties with a relative permittivity of 5.6 and a dielectric loss of 0.003 at 5 GHz at the maximum filler loading of 0.5 volume fraction. The composite exhibits low water absorption, excellent thermal and mechanical properties. It shows a water absorption of 0.03 wt%, a coefficient of thermal expansion of 70 ppm per °C and a room temperature thermal conductivity of 2.4 W mK(-1). The composite shows a tensile strength of 22 MPa and a microhardness of 13.9 kg mm(-2) for the filler loading of 0.5 volume fraction. The HDPE-ZrSiO4 composites show good dielectric, thermal and mechanical properties suitable for microwave soft substrate applications. A microstrip patch antenna is designed and fabricated using the HDPE-0.5 volume fraction ZrSiO4 substrate and the antenna parameters are investigated.

  14. 77 FR 29455 - Notice of Delays in Processing of Special Permits Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... 15080-N Alaska Airlines, Seattle, WA......... 1 06-30-2012 15393-N Savannah Acid Plant LLC, Savannah, GA... volume of special permit Applications. Meaning of Application Number Suffixes N--New application M--Modification request R--Renewal Request P--Party to Exemption Request Issued in Washington, DC, on May 1, 2012...

  15. Novel Liquid Sorbent C02 Removal System for Microgravity Applications

    NASA Technical Reports Server (NTRS)

    Rogers, Tanya; Westover, Shayne; Graf, John

    2017-01-01

    Removing Carbon Dioxide (CO2) from a spacecraft environment for deep space exploration requires a robust system that is low in weight, power, and volume. Current state-of-the-art microgravity compatible CO2 removal systems, such as the carbon dioxide removal assembly (CDRA), utilize solid sorbents that demand high power usage due to high desorption temperatures and a large volume to accommodate for their comparatively low capacity for CO2. Additionally, solid sorbent systems contain several mechanical components that significantly reduce reliability and contribute to a large overall mass. A liquid sorbent based system has been evaluated as an alternative is proposed to consume 65% less power, weight, and volume than solid based CO2 scrubbers. This paper presents the design of a liquid sorbent CO2 removal system for microgravity applications.

  16. Efficient transmission of compressed data for remote volume visualization.

    PubMed

    Krishnan, Karthik; Marcellin, Michael W; Bilgin, Ali; Nadar, Mariappan S

    2006-09-01

    One of the goals of telemedicine is to enable remote visualization and browsing of medical volumes. There is a need to employ scalable compression schemes and efficient client-server models to obtain interactivity and an enhanced viewing experience. First, we present a scheme that uses JPEG2000 and JPIP (JPEG2000 Interactive Protocol) to transmit data in a multi-resolution and progressive fashion. The server exploits the spatial locality offered by the wavelet transform and packet indexing information to transmit, in so far as possible, compressed volume data relevant to the clients query. Once the client identifies its volume of interest (VOI), the volume is refined progressively within the VOI from an initial lossy to a final lossless representation. Contextual background information can also be made available having quality fading away from the VOI. Second, we present a prioritization that enables the client to progressively visualize scene content from a compressed file. In our specific example, the client is able to make requests to progressively receive data corresponding to any tissue type. The server is now capable of reordering the same compressed data file on the fly to serve data packets prioritized as per the client's request. Lastly, we describe the effect of compression parameters on compression ratio, decoding times and interactivity. We also present suggestions for optimizing JPEG2000 for remote volume visualization and volume browsing applications. The resulting system is ideally suited for client-server applications with the server maintaining the compressed volume data, to be browsed by a client with a low bandwidth constraint.

  17. Proceedings of the National Conference on Energy Resource Management. Volume 2: Applications

    NASA Technical Reports Server (NTRS)

    Brumfield, J. O. (Editor); Schiffman, Y. M. (Editor)

    1982-01-01

    Subject areas related to the integration of remotely sensed data with geographic information systems for application in energy resource management are covered. The current trends and advances in the application of these systems to a number of energy concerns are addressed.

  18. Calculation Methods and Conversions for Pesticide Application.

    ERIC Educational Resources Information Center

    Cole, Herbert, Jr.

    This agriculture extension service publication from Pennsylvania State University consists of conversion tables and formulas for determining concentration and rate of application of pesticides. Contents include: (1) Area and volume conversions; (2) Important conversion formulae; (3) Conversions for rates of application; (4) Quantities of pesticide…

  19. Blockade of hyperpolarization-activated channels modifies the effect of beta-adrenoceptor stimulation.

    PubMed

    Zefirov, T L; Ziyatdinova, N I; Gainullin, A A; Zefirov, A L

    2002-05-01

    Experiments on rats showed that blockade of hyperpolarization-activated currents moderates tachycardia induced by beta-adrenoceptor agonist isoproterenol and potentiates the increase in stroke volume produced by this agonist. Electrical stimulation of the vagus nerve against the background of isoproterenol treatment augmented bradycardia and increased stroke volume. Blockade of hyperpolarization-activated currents followed by application of isoproterenol moderated vagus-induced bradycardia and had no effect on the dynamics of stroke volume.

  20. FAA Rotorcraft Research, Engineering, and Development Bibliography 1962-1989

    DTIC Science & Technology

    1990-05-01

    Albert G. Delucien) (NTIS: ADA 102 521) FAA/CT-88/10 Digital Systems Validation Handbook - Volume II (R.L. McDowall, Hardy P. Curd, Lloyd N. Popish... Digital Systems in Avionics and Flight Control Applications, Handbook - Volume I, (Ellis F. Hilt, Donald Eldredge, Jeff Webb, Charles Lucius, Michael S...Structure Statistics of Helicopter GPS Navigation with the Magnavox Z-Set (Robert D. Till) FAA/CT-82/115 Handbook - Volume I, Validation of Digital

  1. High Performing Colleges. The Malcolm Baldrige National Quality Award as a Framework for Improving Higher Education. Volume I: Theory and Concepts [and] Volume II: Case and Practice.

    ERIC Educational Resources Information Center

    Seymour, Daniel, Ed.; And Others

    This publication provides research-based discussion in 20 chapters of possible extension of the Malcolm Baldrige National Quality Award to honor high performing colleges. Chapters are organized into two volumes, the first exploring a broad range of issues from a scholarly point of view and the second emphasizing the practical application of a…

  2. First CLIPS Conference Proceedings, volume 1

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The first Conference of C Language Production Systems (CLIPS) hosted by the NASA-Lyndon B. Johnson Space Center in August 1990 is presented. Articles included engineering applications, intelligent tutors and training, intelligent software engineering, automated knowledge acquisition, network applications, verification and validation, enhancements to CLIPS, space shuttle quality control/diagnosis applications, space shuttle and real-time applications, and medical, biological, and agricultural applications.

  3. Coupled Structural, Thermal, Phase-Change and Electromagnetic Analysis for Superconductors. Volume 1

    NASA Technical Reports Server (NTRS)

    Felippa, C. A.; Farhat, C.; Park, K. C.; Militello, C.; Schuler, J. J.

    1996-01-01

    Described are the theoretical development and computer implementation of reliable and efficient methods for the analysis of coupled mechanical problems that involve the interaction of mechanical, thermal, phase-change and electromagnetic subproblems. The focus application has been the modeling of superconductivity and associated quantum-state phase-change phenomena. In support of this objective the work has addressed the following issues: (1) development of variational principles for finite elements, (2) finite element modeling of the electromagnetic problem, (3) coupling of thermal and mechanical effects, and (4) computer implementation and solution of the superconductivity transition problem. The main accomplishments have been: (1) the development of the theory of parametrized and gauged variational principles, (2) the application of those principled to the construction of electromagnetic, thermal and mechanical finite elements, and (3) the coupling of electromagnetic finite elements with thermal and superconducting effects, and (4) the first detailed finite element simulations of bulk superconductors, in particular the Meissner effect and the nature of the normal conducting boundary layer. The theoretical development is described in two volumes. This volume, Volume 1, describes mostly formulations for specific problems. Volume 2 describes generalization of those formulations.

  4. High-Speed Friction-Stir Welding To Enable Aluminum Tailor-Welded Blanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hovanski, Yuri; Upadhyay, Piyush; Carsley, John

    Current joining technologies for automotive aluminum alloys are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding has been traditionally applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translatemore » to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum welded components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability utilizing a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.« less

  5. A Second Law Based Unstructured Finite Volume Procedure for Generalized Flow Simulation

    NASA Technical Reports Server (NTRS)

    Majumdar, Alok

    1998-01-01

    An unstructured finite volume procedure has been developed for steady and transient thermo-fluid dynamic analysis of fluid systems and components. The procedure is applicable for a flow network consisting of pipes and various fittings where flow is assumed to be one dimensional. It can also be used to simulate flow in a component by modeling a multi-dimensional flow using the same numerical scheme. The flow domain is discretized into a number of interconnected control volumes located arbitrarily in space. The conservation equations for each control volume account for the transport of mass, momentum and entropy from the neighboring control volumes. In addition, they also include the sources of each conserved variable and time dependent terms. The source term of entropy equation contains entropy generation due to heat transfer and fluid friction. Thermodynamic properties are computed from the equation of state of a real fluid. The system of equations is solved by a hybrid numerical method which is a combination of simultaneous Newton-Raphson and successive substitution schemes. The paper also describes the application and verification of the procedure by comparing its predictions with the analytical and numerical solution of several benchmark problems.

  6. Enabling high speed friction stir welding of aluminum tailor welded blanks

    NASA Astrophysics Data System (ADS)

    Hovanski, Yuri

    Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding (FSW) has traditionally been applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translate to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum FSW components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability using a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.

  7. High-Speed Friction-Stir Welding to Enable Aluminum Tailor-Welded Blanks

    NASA Astrophysics Data System (ADS)

    Hovanski, Yuri; Upadhyay, Piyush; Carsley, John; Luzanski, Tom; Carlson, Blair; Eisenmenger, Mark; Soulami, Ayoub; Marshall, Dustin; Landino, Brandon; Hartfield-Wunsch, Susan

    2015-05-01

    Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and they have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high volumes. While friction-stir welding (FSW) has been traditionally applied at linear velocities less than 1 m/min, high-volume production applications demand the process be extended to higher velocities more amenable to cost-sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low-to-moderate welding velocities do not directly translate to high-speed linear FSW. Therefore, to facilitate production of high-volume aluminum FSW components, parameters were developed with a minimum welding velocity of 3 m/min. With an emphasis on weld quality, welded blanks were evaluated for postweld formability using a combination of numerical and experimental methods. An evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum TWBs, which provided validation of the numerical and experimental analysis of laboratory-scale tests.

  8. Obstacles using amorphous materials for volume applications

    NASA Astrophysics Data System (ADS)

    Kiessling, Albert; Reininger, Thomas

    2012-10-01

    This contribution is especially focussed on the attempt to use amorphous or nanocrystalline metals in position sensor applications and to describe the difficulties and obstacles encountered in coherence with the development of appropriate industrial high volume series products in conjunction with the related quality requirements. The main motivation to do these investigations was to beat the generally known sensors especially silicon based Hall-sensors as well as AMR- and GMR-sensors - well known from mobile phones and electronic storage devices like hard discs and others - in terms of cost-effectiveness and functionality.

  9. Micro-Computer Network Architecture for Range Instrumentation Applications - Volume 1

    DTIC Science & Technology

    1991-12-18

    AD-A247 836 MTI-R89-006-28 Micro-Computer Network Architecture for Range Instrumentation Applications Volume 1 Mitchell R. Belzer DTIC Yong M . Cho... M . Belzer, Y. Cho, J. Han 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) 15. PAGE COUNT Final Technical FROM 09SeDQ89...SpecialI I , 1 . . r l n l m s n u m mt l ~ i m I n : t l l l Contents page cover page ....................................................... 1 Report

  10. Fourth - generation languages. Volume 2. Representative 4GLs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, J.

    1986-01-01

    The chapters in Part II each describe one representative product marketed by a vendor other than IBM. (Volume III of this work covers IBM languages.) The chapters in Part II cover the following 4GLs: ADS/ONLINE, APPLICATION FACTORY, DATATRIEVE, FOCUS, IDEAL, INTELLECT, MANTIS, MIMER, NATURAL, NOMAD2, RAMIS II, SYSTEM W, and USE-IT. The Perspective section of Part II presents a general overview of the product and describes its role in the marketplace. The Tutorial section describes how a user employs the language in application development.

  11. Automation Applications in an Advanced Air Traffic Management System : Volume 3. Methodology for Man-Machine Task Allocation

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 3 describes the methodology for man-machine task allocation. It contains a description of man and machine performance capabilities and an explanation of the methodology employed to allocate tasks to human or automated resources. It also presen...

  12. Mathematics and Sports. Mathematical World. Volume 3.

    ERIC Educational Resources Information Center

    Sadovskii, L. E.; Sadovskii, A. L.

    This volume contains some examples of mathematical applications in sports. Sports discussed include tennis, figure skating, gymnastics, track and field, soccer, skiing, hockey, and swimming. Problems and situations are posed and answers with thorough explanations are provided. Chapters include: (1) Mathematics and Sports; (2) What Is Applied…

  13. PROCEEDINGS: EIGHTH SYMPOSIUM ON THE TRANSFER AND UTILIZATION OF PARTICULATE CONTROL TECHNOLOGY - VOLUME 1. ELECTROSTATIC PRECIPITATORS

    EPA Science Inventory

    The two-volume proceedings describe the latest research and development efforts to improve particulate control devices, while treating traditional concerns of operational cost and compliance. Overall, particulate control remains a key issue in the cost and applicability of furnac...

  14. Improved Design of Tunnel Supports : Volume 3 : Finite Element Analysis of the Peachtree Center Station in Atlanta

    DOT National Transportation Integrated Search

    1980-06-01

    Volume 3 contains the application of the three-dimensional (3-D) finite element program, Automatic Dynamic Incremental Nonlinear Analysis (ADINA), which was designed to replace the traditional 2-D plane strain analysis, to a specific location. The lo...

  15. Science Learning: Processes and Applications.

    ERIC Educational Resources Information Center

    Santa, Carol Minnick, Ed.; Alvermann, Donna E., Ed.

    Reflecting a collaboration in terms of content areas, levels, and audience, this volume represents the efforts of science teachers and reading teachers to understand and help one another fine tune their craft. Chapters in the volume include: (1) "Metacognition, Reading and Science Education" (Linda Baker); (2) "Science and Reading:…

  16. Locomotive cab design development. volume III: design application analysis - Interim report

    DOT National Transportation Integrated Search

    1976-10-01

    In Volume II of this service of reports on Locomotive Cab Design Development, changes were recommended in the layout and equipment content of locomotive cabs. This report studies the impact of these changes on the interface of the cab with the rest o...

  17. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    NASA Technical Reports Server (NTRS)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  18. A technique for fast and accurate measurement of hand volumes using Archimedes' principle.

    PubMed

    Hughes, S; Lau, J

    2008-03-01

    A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494 +/- 6 ml and 312 +/- 7 ml for the immersion method and 476 +/- 14 ml and 302 +/- 8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.

  19. Solar cell array design handbook, volume 1

    NASA Technical Reports Server (NTRS)

    Rauschenbach, H. S.

    1976-01-01

    Twelve chapters discuss the following: historical developments, the environment and its effects, solar cells, solar cell filters and covers, solar cell and other electrical interconnections, blocking and shunt diodes, substrates and deployment mechanisms, material properties, design synthesis and optimization, design analysis, procurement, production and cost aspects, evaluation and test, orbital performance, and illustrative design examples. A comprehensive index permits rapid locating of desired topics. The handbook consists of two volumes: Volume 1 is of an expository nature while Volume 2 contains detailed design data in an appendix-like fashion. Volume 2 includes solar cell performance data, applicable unit conversion factors and physical constants, and mechanical, electrical, thermal optical, magnetic, and outgassing material properties. Extensive references are provided.

  20. Applications of cold hibernated elastic memory (CHEM) structures

    NASA Technical Reports Server (NTRS)

    Sokolowski, W. M.; Hayashi, S.

    2003-01-01

    Experiments and analyses have confirmed the feasibility of an innovative, new class of very simple, reliable, low mass, low packaging volume, and low-cost self-deployable structures for space and commercial applications.

  1. Approaches to the design of low-cost HUD systems

    NASA Astrophysics Data System (ADS)

    Wisely, Paul L.; Bleha, Willaim P.

    2014-06-01

    Since their inception during the Second World War in the simple gyro reflector gun sights of combat aircraft such as the Supermarine Spitfire, HUDs have been developed to achieve ever greater capability and performance, initially in military applications but in the final quarter of the last century for civil applications. With increased performance and capability came increased complexity and an attendant steady increase in cost such that HUDs in civil applications are only to be found in some large passenger and high end business jets. The physical volume of current solutions also has a significant impact on where they may be fitted and this paper discusses techniques and approaches to reduce the volume and costs associated with HUD implementation thereby making the operational and safety benefits of HUD available to a broader range of applications in lower cost airframes.

  2. Pesticide deposition on coveralls during vineyard applications.

    PubMed

    Coffman, C W; Obendorf, S K; Derksen, R C

    1999-08-01

    Deposition of pesticide on the clothing of the applicator was studied in a commercial vineyard using two different application technologies. A typical air-assisted sprayer with centrifugal fans delivered a concentrated spray. A tunnel or hooded sprayer was used at two carrier rates-high volume, low concentration versus low volume, high concentration-to apply Dithane M-45, an agricultural fungicide, at 3,375 g/ha on a light to medium density canopy. Deposition of pesticide was on the coveralls worn by the operator for all applications with a deposition range of 0.43 to 0.63 ng/cm2. The deposition on the clothing was higher for the air-assist sprayer than for the hooded sprayer. However, reducing the volume of water in the non-air assist hooded sprayer offered no advantage in terms of decreasing operator exposure. While the deposition of pesticide on the coveralls of the applicator was fairly uniformly distributed on the garment surface, the neck, shoulder, and upper right arm of our right-handed operator had the highest amount of pesticide deposit and the lower left quadrant of the garment had the lowest deposition. Results of this study indicate that vineyard applicator exposure can be reduced by use of the hooded non-air assisted sprayer and that extra protection is needed in the region of the neck, shoulder, and arm, and attention to the habits of the tractor driver is required.http://link.springer-ny. com/link/service/journals/00244/bibs/37n2p273.html

  3. Long life, low cost, rechargeable AgZn battery for non-military applications

    NASA Astrophysics Data System (ADS)

    Brown, Curtis C.

    1996-03-01

    Of the rechargeable (secondary) battery systems with mature technology, the silver oxide-zinc system (AgZn) safely offers the highest power and energy (watts and watt hours) per unit of volume and mass. As a result they have long been used for aerospace and defense applications where they have also proven their high reliability. In the past, the expense associated with the cost of silver and the resulting low production volume have limited their commercial application. However, the relative low cost of silver now make this system feasible in many applications where high energy and reliability are required. One area of commercial potential is power for a new generation of sophisticated, portable medical equipment. AgZn batteries have recently proven ``enabling technology'' for power critical, advanced medical devices. By extending the cycle calendar life to the system (offers both improved performance and lower operating cost), a combination is achieved which may enable a wide range of future electrical devices. Other areas where AgZn batteries have been used in nonmilitary applications to provide power to aid in the development of commercial equipment have been: (a) Electrically powered vehicles; (b) Remote sensing in nuclear facilities; (c) Special effects equipment for movies; (d) Remote sensing in petroleum pipe lines; (e) Portable computers; (f) Fly by wire systems for commercial aircraft; and (g) Robotics. However none of these applications have progressed to the level where the volume required will significantly lower cost.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pötter, Richard; Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna; Federico, Mario

    Purpose: To define, in the setting of cervical cancer, to what extent information from additional pretreatment magnetic resonance imaging (MRI) without the brachytherapy applicator improves conformity of CT-based high-risk clinical target volume (CTV{sub HR}) contours, compared with the MRI for various tumor stages (International Federation of Gynecology and Obstetrics [FIGO] stages I-IVA). Methods and Materials: The CTV{sub HR} was contoured in 39 patients with cervical cancer (FIGO stages I-IVA) (1) on CT images based on clinical information (CTV{sub HR}-CT{sub Clinical}) alone; and (2) using an additional MRI before brachytherapy, without the applicator (CTV{sub HR}-CT{sub pre-BT} {sub MRI}). The CT contours were compared withmore » reference contours on MRI with the applicator in place (CTV{sub HR}-MRI{sub ref}). Width, height, thickness, volumes, and topography were analyzed. Results: The CT-MRI{sub ref} differences hardly varied in stage I tumors (n=8). In limited-volume stage IIB and IIIB tumors (n=19), CTV{sub HR}-CT{sub pre-BT} {sub MRI}–MRI{sub ref} volume differences (2.6 cm{sup 3} [IIB], 7.3 cm{sup 3} [IIIB]) were superior to CTV{sub HR}-CT{sub Clinical}–MRI{sub ref} (11.8 cm{sup 3} [IIB], 22.9 cm{sup 3} [IIIB]), owing to significant improvement of height and width (P<.05). In advanced disease (n=12), improved agreement with MR volume, width, and height was achieved for CTV{sub HR}-CT{sub pre-BT} {sub MRI}. In 5 of 12 cases, MRI{sub ref} contours were partly missed on CT. Conclusions: Pre-BT MRI helps to define CTV{sub HR} before BT implantation appropriately, if only CT images with the applicator in place are available for BT planning. Significant improvement is achievable in limited-volume stage IIB and IIIB tumors. In more advanced disease (extensive IIB to IVA), improvement of conformity is possible but may be associated with geographic misses. Limited impact on precision of CTV{sub HR}-CT is expected in stage IB tumors.« less

  5. Logistics of Oil Spill Dispersant Application. Volume II. Application Techniques, Stockpiling, Dispersant Selection Strategies

    DOT National Transportation Integrated Search

    1982-11-01

    The use of chemicals for oil spill dispersal, while not presently widespread in the U.S., would have implications for the U.S. Coast Guard's Marine Environmental Protection program. This report explores the logistics of oil disperant application by t...

  6. 2012 Application Trends Survey. Early Release Edition

    ERIC Educational Resources Information Center

    Estrada, Rebecca; Bruggeman, Paula

    2012-01-01

    The 2012 Application Trends Survey conducted by the Graduate Management Admission Council[R] (GMAC[R]) is the industry source for comprehensive statistics and timely insights into the demand for graduate management education worldwide. Since 2000, this survey of admission professionals has provided information on application volume trends,…

  7. 78 FR 5437 - Combined Notice of Filings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-25

    ...: Docket Numbers: RP13-451-000. Applicants: Gulf Crossing Pipeline Company LLC. Description: IT Discount....m. ET 1/29/13. Docket Numbers: RP13-452-000. Applicants: Gulf South Pipeline Company, LP...: RP13-458-000. Applicants: Trailblazer Pipeline Company LLC. Description: Cancel 5th Revised Volume to...

  8. Vehicle-to-infrastructure (V2I) safety applications : performance requirements, vol. 1, introduction and common requirements.

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the first of a seven volume report that describes performance requirements for connected vehicle vehicle-to-infrastructure (V2I) Safety Applications developed for the U.S. Department of Transportation (U.S. DOT). The applications add...

  9. Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

    NASA Technical Reports Server (NTRS)

    Devismes, Damien; Cohen, Barbara; Miller, J.-S.; Gillot, P.-Y.; Lefevre, J.-C.; Boukari, C.

    2014-01-01

    These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed.

  10. Practical Nursing, Volume I. Health Occupations Education.

    ERIC Educational Resources Information Center

    Rogers, Helen W.; And Others

    This curriculum guide provides teachers with up-to-date information and skill-related applications needed by the practical nurse. The volume contains three sections and 24 instructional units: Personal Vocational Relationships (6 units), Nutrition (3 units), and Basic Nursing Principles and Applied Skills (15 units covering such topics as…

  11. Surrogate Plant Data Base : Volume 1. Introduction, Appendix A : The Development of Surrogate Plant Data ; Appendix B : Application of the Surrogate .

    DOT National Transportation Integrated Search

    1983-03-01

    This four volume report consists of a data base describing "surrogate" automobile and truck manufacturing plants developed as part of a methodology for evaluating capital investment requirements in new manufacturing facilities to build new fleets of ...

  12. New Trends in Mathematics Teaching, Volume III.

    ERIC Educational Resources Information Center

    United Nations Educational, Scientific, and Cultural Organization, Paris (France).

    Each of the ten chapters in this volume is intended to present an objective analysis of the trends of some important subtopic in mathematics education and each includes a bibliography for fuller study. The chapters cover primary school mathematics, algebra, geometry, probability and statistics, analysis, logic, applications of mathematics, methods…

  13. Planning and Troubleshooting Guide.

    ERIC Educational Resources Information Center

    1994

    This reference guide serves as an index for an 11-volume series of handbooks that offer guidelines to school administrators on the application and implementation of Total Quality Management (TQM) principles to education--Total Quality Education (TQE). The topics are listed in alphabetical order to show the corresponding volume and page number(s).…

  14. Air Pollution. Part A: Analysis.

    ERIC Educational Resources Information Center

    Ledbetter, Joe O.

    Two facets of the engineering control of air pollution (the analysis of possible problems and the application of effective controls) are covered in this two-volume text. Part A covers Analysis, and Part B, Prevention and Control. (This review is concerned with Part A only.) This volume deals with the terminology, methodology, and symptomatology…

  15. Annual Review of Applied Linguistics, Volume 5, 1984.

    ERIC Educational Resources Information Center

    Kaplan, Robert B., Ed.

    This volume of the annual review includes introductory remarks by G. Richard Tucker and these papers: "Current Issues in Bilingualism: An Update of Directions in Research" (Braj B. Kachru); "Psycholinguistics: Application. The Writing System as a Native Language for the Deaf" (Danny D. Steinberg); "Sociolinguistics: Theory" (Monica Heller);…

  16. TELESCAN. Volume 4, Issues 1-10, September 1984-June 1985.

    ERIC Educational Resources Information Center

    TELESCAN, 1985

    1985-01-01

    A digest about how higher education can use new telecommunications technologies, especially to reach students in off-campus settings, is presented. Ten issues of volume 4 of the newsletter "TELESCAN" include information on legislation and trends in the applications of technology-based instruction in postsecondary education. Also included are…

  17. Automation Applications in an Advance Air Traffic Management System : Volume IIB : Functional Analysis of Air Traffic Management (Cont'd)

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 2 contains the analysis and description of air traffic management activities at three levels of detail - functions, subfunctions, and tasks. A total of 265 tasks are identified and described, and the flow of information inputs and outputs amon...

  18. Twentieth Annual Conference on Manual Control, Volume 2

    NASA Technical Reports Server (NTRS)

    Hart, S. G. (Compiler); Hartzell, E. J. (Compiler)

    1984-01-01

    Volume II contains thirty two complete manuscripts and five abstracts. The topics covered include the application of event-related brain potential analysis to operational problems, the subjective evaluation of workload, mental models, training, crew interaction analysis, multiple task performance, and the measurement of workload and performance in simulation.

  19. 75 FR 47296 - Combined Notice of Filings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-05

    ... Tariff, Fourth Revised Volume 1A, to be effective 8/1/10. Filed Date: 07/28/2010. Accession Number..., Fifth Revised Volume 1 to be effective 9/1/10. Filed Date: 07/28/2010. Accession Number: 20100728-0208...-1007-000. Applicants: Rockies Express Pipeline LLC. Description: Rockies Express Pipeline LLC submits...

  20. Unified Technical Concepts. Application Modules Volume II.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    Unified Technical Concepts (UTC) is a modular system for teaching applied physics in two-year postsecondary technician programs. This UTC laboratory textbook, the second of two volumes, consists of 45 learning modules dealing with basic concepts of physics. Addressed in the individual chapters of the guide are the following topics: force…

  1. Automated Applications in an Advanced Air Traffic Management System : Volume 2B. Functional Analysis of Air Traffic Management (Cont'd.)

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 2 contains the analysis and description of air traffic management activities at three levels of detail - functions, subfunctions, and tasks. A total of 265 tasks are identified and described, and the flow of information inputs and outputs amon...

  2. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the applicability provisions of § 86.1801. Eligible small volume manufacturers or small volume test... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points... the highest mileage point run during mileage accumulation (e.g. the full useful life mileage...

  3. Behavioral Science Elementary Teacher Education Program. Final Report. Volume II.

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing.

    Volume II separately details two model components: Scholarly Modes of Knowledge, in which problem-solving techniques and the applicability of subject content to teaching are emphasized, and Professional Use of Knowledge, in which the student translates what he knows about various disciplines and human learning into instructional strategies. Each…

  4. Automation Applications in an Advanced Air Traffic Management System : Volume 2A. Functional Analysis of Air Traffic Management.

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 2 contains the analysis and description of air traffic management activities at three levels of detail - functions, subfunctions, and tasks. A total of 265 tasks are identified and described, and the flow of information inputs and outputs amon...

  5. Automation Applications in an Advanced Air Traffic Management System : Volume 2C. Functional Analysis of Air Traffic Management (Cont.'d)

    DOT National Transportation Integrated Search

    1974-08-01

    Volume 2 contains the analysis and description of air traffic management activities at three levels of detail - functions, subfunctions, and tasks. A total of 265 tasks are identified and described, and the flow of information inputs and outputs amon...

  6. Wet Scrubber System Study. Volume II. Final Report and Bibliography.

    ERIC Educational Resources Information Center

    Calvert, Seymour; And Others

    This report is the second volume of a two-part study on wet scrubber systems. The study was undertaken to achieve the following objectives: (1) evaluate current engineering technology, (2) evaluate existing scrubber systems, (3) investigate present usage problems, (4) determine potential new applications, and (5) develop specific research…

  7. Formal Methods Specification and Analysis Guidebook for the Verification of Software and Computer Systems. Volume 2; A Practitioner's Companion

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This guidebook, the second of a two-volume series, is intended to facilitate the transfer of formal methods to the avionics and aerospace community. The 1st volume concentrates on administrative and planning issues [NASA-95a], and the second volume focuses on the technical issues involved in applying formal methods to avionics and aerospace software systems. Hereafter, the term "guidebook" refers exclusively to the second volume of the series. The title of this second volume, A Practitioner's Companion, conveys its intent. The guidebook is written primarily for the nonexpert and requires little or no prior experience with formal methods techniques and tools. However, it does attempt to distill some of the more subtle ingredients in the productive application of formal methods. To the extent that it succeeds, those conversant with formal methods will also nd the guidebook useful. The discussion is illustrated through the development of a realistic example, relevant fragments of which appear in each chapter. The guidebook focuses primarily on the use of formal methods for analysis of requirements and high-level design, the stages at which formal methods have been most productively applied. Although much of the discussion applies to low-level design and implementation, the guidebook does not discuss issues involved in the later life cycle application of formal methods.

  8. Application of Remote Sensing to the Chesapeake Bay Region. Volume 2: Proceedings

    NASA Technical Reports Server (NTRS)

    Chen, W. T. (Editor); Freas, G. W., Jr. (Editor); Hickman, G. D. (Editor); Pemberton, D. A. (Editor); Wilkerson, T. D. (Editor); Adler, I. (Editor); Laurie, V. J. (Editor)

    1978-01-01

    A conference was held on the application of remote sensing to the Chesapeake Bay region. Copies of the papers, resource contributions, panel discussions, and reports of the working groups are presented.

  9. The area-time-integral technique to estimate convective rain volumes over areas applied to satellite data - A preliminary investigation

    NASA Technical Reports Server (NTRS)

    Doneaud, Andre A.; Miller, James R., Jr.; Johnson, L. Ronald; Vonder Haar, Thomas H.; Laybe, Patrick

    1987-01-01

    The use of the area-time-integral (ATI) technique, based only on satellite data, to estimate convective rain volume over a moving target is examined. The technique is based on the correlation between the radar echo area coverage integrated over the lifetime of the storm and the radar estimated rain volume. The processing of the GOES and radar data collected in 1981 is described. The radar and satellite parameters for six convective clusters from storm events occurring on June 12 and July 2, 1981 are analyzed and compared in terms of time steps and cluster lifetimes. Rain volume is calculated by first using the regression analysis to generate the regression equation used to obtain the ATI; the ATI versus rain volume relation is then employed to compute rain volume. The data reveal that the ATI technique using satellite data is applicable to the calculation of rain volume.

  10. Data catalog series for space science and applications flight missions. Volume 4B: Descriptions of data sets from meteorological and terrestrial applications spacecraft and investigations

    NASA Technical Reports Server (NTRS)

    Ng, Carolyn; Stonesifer, G. Richard

    1989-01-01

    The main purpose of the data catalog series is to provide descriptive references to data generated by space science flight missions. The data sets described include all of the actual holdings of the Space Science Data Center (NSSDC), all data sets for which direct contact information is available, and some data collections held and serviced by foreign investigators, NASA and other U.S. government agencies. This volume contains narrative descriptions of data sets from meteorological and terrestrial applications spacecraft and investigations. The following spacecraft series are included: Mariner, Pioneer, Pioneer Venus, Venera, Viking, Voyager, and Helios. Separate indexes to the planetary and interplanetary missions are also provided.

  11. Data catalog series for space science and applications flight missions. Volume 4A: Descriptions of meteorological and terrestrial applications spacecraft and investigations

    NASA Technical Reports Server (NTRS)

    Ng, C. Y. (Editor); Sheu, Y. T. P. (Editor)

    1985-01-01

    The National Space Science Data Center (NSSDC) provides data from and information about space science and applications flight investigations in support of additional studies beyond those performed as the principal part of any flight mission. The Earth-orbiting spacecraft for investigations of the earth and its atmosphere is discussed. Geodetic tracking data are included in this category. The principal subject areas presented are meteorology and earth resources survey, and the spacecraft selection is made according to those subjects. All experiments on board the spacecraft are described. No attempt is made to reference investigations that are related to the above disciplines, but that are described in other volumes of this series.

  12. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    PubMed

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P < 0.001 and r = 0.94, P < 0.001). The preoperative and postoperative split estimated glomerular filtration rate of the operated kidney showed a moderate correlation with split renal function (r = 0.39, P = 0.004 and r = 0.49, P < 0.001). The correlation between reductions in split renal function and split renal volume of the operated kidney (r = 0.87, P < 0.001) was stronger than that between split renal function and percent reduction in split estimated glomerular filtration rate (r = 0.64, P < 0.001). The split renal volume calculated using computed tomography-based renal volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  13. Utilizing off-the-shelf parts for the next generation of space exploration

    NASA Technical Reports Server (NTRS)

    Stosic, D. K.; Hatch, W. A.; Lux, J. P.; McMaster, R. L.

    2001-01-01

    Unscreened commercial, off-the-shelf (COTS) parts, in space applications are especially encouraging when the possibility of capitalizing on the extensive development for high-volume consumer applications is considered. Other applications for MMIC parts in space could possibly open new doors in the future.

  14. 19 CFR 191.193 - Application procedure for compliance program.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... participation in the drawback compliance program. This includes any person, corporation or business entity that... part). The detail required in the application shall take into account the size and nature of the applicant's drawback program, the type of drawback claims filed, and the dollar value and volume of claims...

  15. OSTA commonality analysis, volume 2

    NASA Technical Reports Server (NTRS)

    Stolarik, E. G.

    1981-01-01

    The 13 OSTA disciplines are examined and the applications being performed under each discipline and the parameter requirements associated with the various applications are identified. It contains a variety of printouts from the commonality database built using DRS on the Vax. It also shows commonality of parameter requirements by discipline and by application.

  16. Methodology for 2012 Application Trends Survey

    ERIC Educational Resources Information Center

    Graduate Management Admission Council, 2012

    2012-01-01

    From early June to late July 2012, the Graduate Management Admission Council[R] (GMAC[R]) conducted the "Application Trends Survey", its annual survey of business school admission professionals worldwide to assess how application volume at MBA and other graduate management programs compared with that from the same period in 2011. This…

  17. Application Trends Survey. 2014 Survey Report

    ERIC Educational Resources Information Center

    Worthington, Rebecca; Bruggeman, Paula

    2014-01-01

    Now in its 15th year, the Graduate Management Admission Council's assessment of application volume trends for graduate management programs offers timely insights into demographic shifts and other factors defining the candidate pools for the 2014 application cycle. Responses collected in the 2014 survey represent a record-breaking total of 748 MBA,…

  18. The future of automation for high-volume wafer fabrication and ASIC manufacturing

    NASA Astrophysics Data System (ADS)

    Hughes, Randall A.; Shott, John D.

    1986-12-01

    A framework is given to analyze the future trends in semiconductor manufacturing automation systems, focusing specifically on the needs of ASIC (application-specific integrated circuit) or custom integrated circuit manufacturing. Advances in technologies such as gate arrays and standard cells now make it significantly easier to obtain system cost and performance advantages by integrating nonstandard functions on silicon. ASICs are attractive to U.S. manufacturers because they place a premium on sophisticated design tools, familiarity with customer needs and applications, and fast turn-around fabrication. These are areas where U.S. manufacturers believe they have an advantage and, consequently, will not suffer from the severe price/manufacturing competition encountered in conventional high-volume semiconductor products. Previously, automation was often considered viable only for high-volume manufacturing, but automation becomes a necessity in the new ASIC environment.

  19. Earth Observations Division version of the Laboratory for Applications of Remote Sensing System (EOD-LARSYS) user guide for the IBM 370/148. Volume 2: User reference manual

    NASA Technical Reports Server (NTRS)

    Aucoin, P. J.; Stewart, J.; Mckay, M. F. (Principal Investigator)

    1980-01-01

    This document presents instructions for analysts who use the EOD-LARSYS as programmed on the Purdue University IBM 370/148 (recently replaced by the IBM 3031) computer. It presents sample applications, control cards, and error messages for all processors in the system and gives detailed descriptions of the mathematical procedures and information needed to execute the system and obtain the desired output. EOD-LARSYS is the JSC version of an integrated batch system for analysis of multispectral scanner imagery data. The data included is designed for use with the as built documentation (volume 3) and the program listings (volume 4). The system is operational from remote terminals at Johnson Space Center under the virtual machine/conversational monitor system environment.

  20. Zinc-blende to rocksalt transition in SiC in a laser-heated diamond-anvil cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daviau, Kierstin; Lee, Kanani K. M.

    2017-04-18

    We explore the stability of the ambient pressure zinc-blende polymorph (B3) structure of silicon carbide (SiC) at high pressures and temperatures where it transforms to the rocksalt (B1) structure. We find that the transition occurs ~40 GPa lower than previously measured when heated to moderately high temperatures. A lower transition pressure is consistent with the transition pressures predicted in numerous ab initio computations. We find a large volume decrease across the transition of ~17%, with the volume drop increasing at higher formation pressures, suggesting this transition is volume driven yielding a nearly pressure-independent Clapeyron slope. Such a dramatic density increasemore » occurring at pressure is important to consider in applications where SiC is exposed to extreme conditions, such as in industrial applications or planetary interiors.« less

  1. Tracking of the micro-structural changes of levonorgestrel-releasing intrauterine system by positron annihilation lifetime spectroscopy.

    PubMed

    Patai, Kálmán; Szente, Virág; Süvegh, Károly; Zelkó, Romána

    2010-12-01

    The morphology and the micro-structural changes of levonorgestrel-releasing intrauterine systems (IUSs) were studied in relation to the duration of their application. The morphology of the removed IUSs was examined without pre-treatment by scanning electron microscopy. The micro-structural changes of the different layers of IUSs were tracked by positron annihilation lifetime spectroscopy. Besides the previously found incrustation formation, the free volume of the hormone containing reservoir was remarkably increased after 3 years of application, thus increasing the real volume of the core of the systems. Although the free volume of the membrane encasing the core was not significantly changed in the course of the application, as a result of the core expansion, microcracks could be formed on the membrane surface. Along these cracks, deposits of different compositions can be formed, causing inflammatory complications and influencing the drug release of IUSs. Stability tests in combination with micro-structural screening of such IUSs could be required during their development phase to avoid the undesired side effects. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  2. Rapid jetting status inspection and accurate droplet volume measurement for a piezo drop-on-demand inkjet print head using a scanning mirror for display applications

    NASA Astrophysics Data System (ADS)

    Shin, Dong-Youn; Kim, Minsung

    2017-02-01

    Despite the inherent fabrication simplicity of piezo drop-on-demand inkjet printing, the non-uniform deposition of colourants or electroluminescent organic materials leads to faulty display products, and hence, the importance of rapid jetting status inspection and accurate droplet volume measurement increases from a process perspective. In this work, various jetting status inspections and droplet volume measurement methods are reviewed by discussing their advantages and disadvantages, and then, the opportunities for the developed prototype with a scanning mirror are explored. This work demonstrates that jetting status inspection of 384 fictitious droplets can be performed within 17 s with maximum and minimum measurement accuracies of 0.2 ± 0.5 μ m for the fictitious droplets of 50 μ m in diameter and -1.2 ± 0.3 μ m for the fictitious droplets of 30 μ m in diameter, respectively. In addition to the new design of an inkjet monitoring instrument with a scanning mirror, two novel methods to accurately measure the droplet volume by amplifying a minute droplet volume difference and then converting to other physical properties are suggested and the droplet volume difference of ±0.3% is demonstrated to be discernible using numerical simulations, even with the low measurement accuracy of 1 μ m . When the fact is considered that the conventional vision-based method with a CCD camera requires the optical measurement accuracy less than 25 nm to measure the volume of an in-flight droplet in the nominal diameter of 50 μ m at the same volume measurement accuracy, the suggested method with the developed prototype offers a whole new opportunity to inkjet printing for display applications.

  3. Rapid jetting status inspection and accurate droplet volume measurement for a piezo drop-on-demand inkjet print head using a scanning mirror for display applications.

    PubMed

    Shin, Dong-Youn; Kim, Minsung

    2017-02-01

    Despite the inherent fabrication simplicity of piezo drop-on-demand inkjet printing, the non-uniform deposition of colourants or electroluminescent organic materials leads to faulty display products, and hence, the importance of rapid jetting status inspection and accurate droplet volume measurement increases from a process perspective. In this work, various jetting status inspections and droplet volume measurement methods are reviewed by discussing their advantages and disadvantages, and then, the opportunities for the developed prototype with a scanning mirror are explored. This work demonstrates that jetting status inspection of 384 fictitious droplets can be performed within 17 s with maximum and minimum measurement accuracies of 0.2 ± 0.5 μm for the fictitious droplets of 50 μm in diameter and -1.2 ± 0.3 μm for the fictitious droplets of 30 μm in diameter, respectively. In addition to the new design of an inkjet monitoring instrument with a scanning mirror, two novel methods to accurately measure the droplet volume by amplifying a minute droplet volume difference and then converting to other physical properties are suggested and the droplet volume difference of ±0.3% is demonstrated to be discernible using numerical simulations, even with the low measurement accuracy of 1 μm. When the fact is considered that the conventional vision-based method with a CCD camera requires the optical measurement accuracy less than 25 nm to measure the volume of an in-flight droplet in the nominal diameter of 50 μm at the same volume measurement accuracy, the suggested method with the developed prototype offers a whole new opportunity to inkjet printing for display applications.

  4. Specific storage volumes: A useful tool for CO2 storage capacity assessment

    USGS Publications Warehouse

    Brennan, S.T.; Burruss, R.C.

    2006-01-01

    Subsurface geologic strata have the potential to store billions of tons of anthropogenic CO2; therefore, geologic carbon sequestration can be an effective mitigation tool used to slow the rate at which levels of atmospheric CO2 are increasing. Oil and gas reservoirs, coal beds, and saline reservoirs can be used for CO2 storage; however, it is difficult to assess and compare the relative storage capacities of these different settings. Typically, CO2 emissions are reported in units of mass, which are not directly applicable to comparing the CO2 storage capacities of the various storage targets. However, if the emission values are recalculated to volumes per unit mass (specific volume) then the volumes of geologic reservoirs necessary to store CO2 emissions from large point sources can be estimated. The factors necessary to convert the mass of CO2 emissions to geologic storage volume (referred to here as Specific Storage Volume or 'SSV') can be reported in units of cubic meters, cubic feet, and petroleum barrels. The SSVs can be used to estimate the reservoir volume needed to store CO2 produced over the lifetime of an individual point source, and to identify CO2 storage targets of sufficient size to meet the demand from that given point source. These storage volumes also can then be projected onto the land surface to outline a representative "footprint," which marks the areal extent of storage. This footprint can be compared with the terrestrial carbon sequestration capacity of the same land area. The overall utility of this application is that the total storage capacity of any given parcel of land (from surface to basement) can be determined, and may assist in making land management decisions. ?? Springer Science+Business Media, LLC 2006.

  5. Multi-atlas pancreas segmentation: Atlas selection based on vessel structure.

    PubMed

    Karasawa, Ken'ichi; Oda, Masahiro; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Chu, Chengwen; Zheng, Guoyan; Rueckert, Daniel; Mori, Kensaku

    2017-07-01

    Automated organ segmentation from medical images is an indispensable component for clinical applications such as computer-aided diagnosis (CAD) and computer-assisted surgery (CAS). We utilize a multi-atlas segmentation scheme, which has recently been used in different approaches in the literature to achieve more accurate and robust segmentation of anatomical structures in computed tomography (CT) volume data. Among abdominal organs, the pancreas has large inter-patient variability in its position, size and shape. Moreover, the CT intensity of the pancreas closely resembles adjacent tissues, rendering its segmentation a challenging task. Due to this, conventional intensity-based atlas selection for pancreas segmentation often fails to select atlases that are similar in pancreas position and shape to those of the unlabeled target volume. In this paper, we propose a new atlas selection strategy based on vessel structure around the pancreatic tissue and demonstrate its application to a multi-atlas pancreas segmentation. Our method utilizes vessel structure around the pancreas to select atlases with high pancreatic resemblance to the unlabeled volume. Also, we investigate two types of applications of the vessel structure information to the atlas selection. Our segmentations were evaluated on 150 abdominal contrast-enhanced CT volumes. The experimental results showed that our approach can segment the pancreas with an average Jaccard index of 66.3% and an average Dice overlap coefficient of 78.5%. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Adapting PC104Plus for Space

    NASA Technical Reports Server (NTRS)

    Abbott, Larry; Cox, Gary; Nguyen, Hai

    2000-01-01

    This article addresses the issues associated with adapting the commercial PC104Plus standard and its associated architecture to the requirements of space applications. In general, space applications exhibit extreme constraints on power, weight, and volume. EMI and EMC are also issues of significant concern. Additionally, space applications have to survive high radiation environment. Finally, NASA is always concerned about achieving cost effective solutions that are compatible with safety and launch constraints. Weight and volume constraints are directly related to high launch cost. Power on the other hand is not only related to the high launch costs, but are related to the problem of dissipating the resulting heat once in space. The article addresses why PC104Plus is an appropriate solution for the weight and volume issues. The article also addresses what NASA did electrically to reduce power consumption and mechanically dissipate the associated heat in a microgravity and vacuum environment, and how these solutions allow NASA to integrate various sizes of ruggedized custom PC104 boards with COTS, PC104 complaint boards for space applications. In addition to the mechanical changes to deal with thermal dissipation NASA also made changes to minimize EMI. Finally, radiation issues are addressed as well as the architectural and testing solutions and the implications for use of COTS PC104Plus boards.

  7. Main Trend Extraction Based on Irregular Sampling Estimation and Its Application in Storage Volume of Internet Data Center

    PubMed Central

    Dou, Chao

    2016-01-01

    The storage volume of internet data center is one of the classical time series. It is very valuable to predict the storage volume of a data center for the business value. However, the storage volume series from a data center is always “dirty,” which contains the noise, missing data, and outliers, so it is necessary to extract the main trend of storage volume series for the future prediction processing. In this paper, we propose an irregular sampling estimation method to extract the main trend of the time series, in which the Kalman filter is used to remove the “dirty” data; then the cubic spline interpolation and average method are used to reconstruct the main trend. The developed method is applied in the storage volume series of internet data center. The experiment results show that the developed method can estimate the main trend of storage volume series accurately and make great contribution to predict the future volume value. 
 PMID:28090205

  8. Main Trend Extraction Based on Irregular Sampling Estimation and Its Application in Storage Volume of Internet Data Center.

    PubMed

    Miao, Beibei; Dou, Chao; Jin, Xuebo

    2016-01-01

    The storage volume of internet data center is one of the classical time series. It is very valuable to predict the storage volume of a data center for the business value. However, the storage volume series from a data center is always "dirty," which contains the noise, missing data, and outliers, so it is necessary to extract the main trend of storage volume series for the future prediction processing. In this paper, we propose an irregular sampling estimation method to extract the main trend of the time series, in which the Kalman filter is used to remove the "dirty" data; then the cubic spline interpolation and average method are used to reconstruct the main trend. The developed method is applied in the storage volume series of internet data center. The experiment results show that the developed method can estimate the main trend of storage volume series accurately and make great contribution to predict the future volume value. 
 .

  9. Durability of geosynthetics for highway applications

    DOT National Transportation Integrated Search

    2001-01-01

    The research results described in this TechBrief are from four volumes on the subject of durability of geosynthetics for highway applications. Various aspects of geosynthetic durability were addressed in order to develop procedures that could be used...

  10. HEUS-RS applications study, volume 2

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The final report of a High Energy Upper Stage Restartable Solid (HEUS-RS) Applications Study is presented. The material deals with launch program cost comparisons associated with meeting NASA mission model requirements with several different launch vehicle approaches.

  11. Durability of geosynthetics for highway applications : Tech brief.

    DOT National Transportation Integrated Search

    2000-01-01

    The research results described herein are included in four volumes on the : subject of Durability of Geosynthetics for Highway Applications. Various : aspects of geosynthetic durability were addressed in order to develop : procedures that could be us...

  12. Validation of Student and Parent Reported Data on the Basic Grant Application Form: Corrections Analysis Study. Final Report, Volume 4.

    ERIC Educational Resources Information Center

    Vogel, Ronald J.

    A study was conducted in 1976 of applicants who submitted corrections or amendments to their Student Eligibility Reports (SERs) for the Basic Educational Opportunity Grant (BEOG) Program. The objective was to review the applications corrections process and to determine factors linked to applicants' use of correction procedures. Attention was…

  13. An Application of Cartesian-Grid and Volume-of-Fluid Methods to Numerical Ship Hydrodynamics

    DTIC Science & Technology

    2007-10-01

    water-particle ve- locity is discontinuous across the air-water interface, and where CiEA is the Levi - Civita function. rj is the moment the vertical...methods and volume-of- immersed- body and volume-of-fluid (VOF) methods. fluid methods is used to simulate breaking waves around The governing equations are...of a ship hull is used as input to automat- body -fitted grids. The sole geometric input into NFA ically generate an immersed-boundary representation of

  14. The Environment for Application Software Integration and Execution (EASIE) version 1.0. Volume 1: Executive overview

    NASA Technical Reports Server (NTRS)

    Rowell, Lawrence F.; Davis, John S.

    1989-01-01

    The Environment for Application Software Integration and Execution (EASIE) provides a methodology and a set of software utility programs to ease the task of coordinating engineering design and analysis codes. EASIE was designed to meet the needs of conceptual design engineers that face the task of integrating many stand-alone engineering analysis programs. Using EASIE, programs are integrated through a relational database management system. Volume 1, Executive Overview, gives an overview of the functions provided by EASIE and describes their use. Three operational design systems based upon the EASIE software are briefly described.

  15. Dual use application of killer app FHE products for Mil/Aero

    NASA Astrophysics Data System (ADS)

    Hackler, R. Douglas

    2016-05-01

    The flexible electronics industry has adopted flexible hybrid electronic (FHE) systems as a go to market strategy. High volume products are emerging for body worn bio patches, conformal structural appliques and smart labels. These products were principally developed for volume consumer and industrial market solutions but are directly applicable to advanced defense systems. This article highlights the state of the art for bio patch, conformal and smart FHE products and identifies their dual use capability for defense systems. A discussion of the manufacturing base for FHE products is presented and current experimental prototype results and performance are shared.

  16. Rotary-wing aerodynamics. Volume 2: Performance prediction of helicopters

    NASA Technical Reports Server (NTRS)

    Keys, C. N.; Stephniewski, W. Z. (Editor)

    1979-01-01

    Application of theories, as well as, special methods of procedures applicable to performance prediction are illustrated first, on an example of the conventional helicopter and then, winged and tandem configurations. Performance prediction of conventional helicopters in hover and vertical ascent are investigated. Various approaches to performance prediction in forward translation are presented. Performance problems are discussed only this time, a wing is added to the baseline configuration, and both aircraft are compared with respect to their performance. This comparison is extended to a tandem. Appendices on methods for estimating performance guarantees and growth of aircraft concludes this volume.

  17. Unified Technical Concepts. Application Modules Volume I.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    Unified Technical Concepts (UTC) is a modular system for teaching applied physics in two-year postsecondary technician programs. This UTC laboratory textbook, the first of two volumes, consists of 56 learning modules dealing with basic concepts of physics. Addressed in the individual chapters of the guide are the following topics: force, work,…

  18. 40 CFR 86.1829-01 - Durability and emission testing requirements; waivers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... under the provisions of § 86.1828-10(c) and (g). (4) Electric vehicles and fuel cell vehicles. For electric vehicles and fuel cell vehicles, manufacturers may provide a statement in the application for..., including, but not limited to, canister type, canister volume, canister working capacity, fuel tank volume...

  19. 40 CFR 80.104 - Recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and the Virgin Islands, as applicable. (xiv) In the case of butane blended into conventional gasoline under § 80.82, documentation of: (A) The volume of the butane added; (B) The volume of the gasoline prior to and subsequent to the butane blending; (C) The purity and properties of the butane under § 80...

  20. 40 CFR 80.104 - Recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., and the Virgin Islands, as applicable. (xiv) In the case of butane blended into conventional gasoline under § 80.82, documentation of: (A) The volume of the butane added; (B) The volume of the gasoline prior to and subsequent to the butane blending; (C) The purity and properties of the butane under § 80...

  1. Health Information System Simulation. Curriculum Improvement Project. Region II.

    ERIC Educational Resources Information Center

    Anderson, Beth H.; Lacobie, Kevin

    This volume is one of three in a self-paced computer literacy course that gives allied health students a firm base of knowledge concerning computer usage in the hospital environment. It also develops skill in several applications software packages. This volume contains five self-paced modules that allow students to interact with a health…

  2. Development of Techniques and Data for Evaluating Ride Quality, Volume III : Guidelines for Development of Ride-Quality Models and Their Applications

    DOT National Transportation Integrated Search

    1978-02-01

    Ride-quality models for city buses and intercity trains are presented and discussed in terms of their ability to predict passenger comfort and ride acceptability. The report, the last of three volumes, contains procedural guidelines to be employed by...

  3. Student Financial Aid Handbook, 2001-2002. Volume 1: Student Eligibility.

    ERIC Educational Resources Information Center

    Department of Education, Washington, DC. Student Financial Assistance.

    This volume discusses the eligibility requirements for student and parent borrowers from federal financial aid programs. It reviews the factors an aid administrator must consider when reviewing a student's application for a loan and outlines the administrator's responsibilities in checking to make sure that recipients qualify for their aid awards.…

  4. Aids to navigation service force mix 2000 project. Volume 1 : development and application of an aids to navigation service force mix decision support system

    DOT National Transportation Integrated Search

    1992-07-01

    The Aids to Navigation (ATON) Service Force Mix (SFM) 2000 Project is documented in a Project Overview and three separately bound volumes. This is the Project Overview. The Project Overview describes the purpose, approach, analysis, and results of th...

  5. Preliminary design of a solar central receiver for a site-specific repowering application (Saguaro Power Plant). Volume III. Specifications. Final report, October 1982-September 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weber, E.R.

    1983-09-01

    This volume on specifications for the Saguaro Power Plant includes the following: subsystem interface definition document; solar collector subsystem specification; receiver specification; thermal energy storage specification; solar steam generator specification; and master control system specification.

  6. EVALUATION OF THE REAL-TIME AIR-QUALITY MODEL USING THE RAPS (REGIONAL AIR POLLUTION STUDY) DATA BASE. VOLUME 1. OVERVIEW

    EPA Science Inventory

    The theory and programming of statistical tests for evaluating the Real-Time Air-Quality Model (RAM) using the Regional Air Pollution Study (RAPS) data base are fully documented in four report volumes. Moreover, the tests are generally applicable to other model evaluation problem...

  7. Journal of the Society for Accelerative Learning and Teaching; Volume 12, Number 1-4.

    ERIC Educational Resources Information Center

    Schuster, Don, Ed.

    1987-01-01

    The basic focus on this journal, which publishes a wide variety of articles on suggestive and accelerative learning, is Suggestopedia theory, research, and application. Articles in the volume presented here include: "The Effects of Superlearning on Retention/Hypermnesia of Rare English Words in College Students" (Lynn D. Anderson);…

  8. First CLIPS Conference Proceedings, volume 2

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The topics of volume 2 of First CLIPS Conference are associated with following applications: quality control; intelligent data bases and networks; Space Station Freedom; Space Shuttle and satellite; user interface; artificial neural systems and fuzzy logic; parallel and distributed processing; enchancements to CLIPS; aerospace; simulation and defense; advisory systems and tutors; and intelligent control.

  9. Lead free Bi0.5Na0.5TiO3 (BNT) and polyvinylidene fluoride (PVDF) based nanocomposite for energy storage applications

    NASA Astrophysics Data System (ADS)

    Pradhan, Lagen Kumar; Pandey, Rabichandra; Kumar, Sunil; Kar, Manoranjan

    2018-05-01

    Novel ceramic-polymer nanocomposites have great potential for electrical energy storage applications due to its high energy storage density. In the present work, BNT and PVDF based flexible polymer nanocomposites (BNT-PVDF) with different volume fraction (ϕ = 0, 5, 10, 15) were fabricated by solution casting method. Enhancement in beta phase of PVDF polymer matrix with the volume fraction (ϕ = 5, 10, 15) of BNT has been confirmed by X-ray diffraction (XRD) technique as well as Fourier transform infrared (FTIR) spectroscopy analysis. The enhancement of β phase increases as compared to (α) phases with volume fraction (ϕ) of nanofiller (BNT) in the matrix (PVDF) due to internal stress at the interface as well as structural modification of PVDF matrix. BNT-PVDF nanocomposites (with ϕ=10) showed a high dielectric constant (ɛr ≈ 78) relative to pure PVDF (ɛr ≈ 10) at 100 Hz. In addition to this, it exhibits relaxor type ferroelectric behavior with energy storage efficiency up to 77% for the volume fraction (ϕ) of 10.

  10. Functional Requirements for Onboard Management of Space Shuttle Consumables. Volume 2

    NASA Technical Reports Server (NTRS)

    Graf, P. J.; Herwig, H. A.; Neel, L. W.

    1973-01-01

    This report documents the results of the study "Functional Requirements for Onboard Management of Space Shuttle Consumables." The study was conducted for the Mission Planning and Analysis Division of the NASA Lyndon B. Johnson Space Center, Houston, Texas, between 3 July 1972 and 16 November 1973. The overall study program objective was two-fold. The first objective was to define a generalized consumable management concept which is applicable to advanced spacecraft. The second objective was to develop a specific consumables management concept for the Space Shuttle vehicle and to generate the functional requirements for the onboard portion of that concept. Consumables management is the process of controlling or influencing the usage of expendable materials involved in vehicle subsystem operation. The report consists of two volumes. Volume I presents a description of the study activities related to general approaches for developing consumable management, concepts for advanced spacecraft applications, and functional requirements for a Shuttle consumables management concept. Volume II presents a detailed description of the onboard consumables management concept proposed for use on the Space Shuttle.

  11. Coupled Structural, Thermal, Phase-change and Electromagnetic Analysis for Superconductors, Volume 2

    NASA Technical Reports Server (NTRS)

    Felippa, C. A.; Farhat, C.; Park, K. C.; Militello, C.; Schuler, J. J.

    1996-01-01

    Described are the theoretical development and computer implementation of reliable and efficient methods for the analysis of coupled mechanical problems that involve the interaction of mechanical, thermal, phase-change and electromag subproblems. The focus application has been the modeling of superconductivity and associated quantum-state phase change phenomena. In support of this objective the work has addressed the following issues: (1) development of variational principles for finite elements, (2) finite element modeling of the electromagnetic problem, (3) coupling of thermel and mechanical effects, and (4) computer implementation and solution of the superconductivity transition problem. The main accomplishments have been: (1) the development of the theory of parametrized and gauged variational principles, (2) the application of those principled to the construction of electromagnetic, thermal and mechanical finite elements, and (3) the coupling of electromagnetic finite elements with thermal and superconducting effects, and (4) the first detailed finite element simulations of bulk superconductors, in particular the Meissner effect and the nature of the normal conducting boundary layer. The theoretical development is described in two volumes. Volume 1 describes mostly formulation specific problems. Volume 2 describes generalization of those formulations.

  12. Sexual dimorphism of canine volume: a pilot study.

    PubMed

    De Angelis, Danilo; Gibelli, Daniele; Gaudio, Daniel; Cipriani Noce, Filippo; Guercini, Nicola; Varvara, Giuseppe; Sguazza, Emanuela; Sforza, Chiarella; Cattaneo, Cristina

    2015-05-01

    Sex assessment is a crucial part of the biological profile in forensic and archaeological context, but it can be hardly performed in cases of commingled and charred human remains where DNA tests often are not applicable. With time literature have analyzed the sexual dimorphism of teeth (and especially canines), but very few articles take into consideration the teeth volume, although with time several technologies have been introduced in order to assess 3D volume (CT-scan, laser scanner, etc.). This study aims at assessing the sexual dimorphism of dental and pulp chamber volumes of a sample of canines. Cone beam computed tomography analyses were performed by 87 patients (41 males and 46 females, aged between 15 and 83 years) for clinical purposes, and were acquired in order to measure canine volumes. Results show that the dental volume amounted to 0.745 cm(3) (SD 0.126 cm(3)) in males, 0.551 cm(3) (SD 0.130 cm(3)) with a statistically significant difference (p<0.01). A diagnostic threshold of 0.619 cm(3) was stated, which provides a percentage of correct answer of 80.5% in the chosen sample. The novel method was then applied with success to 7 archaeological: where in all the cases the results were concordant with those provided by the assessment of the cranium and pelvis. The study adds a contribution to the wide analysis of dental sexual dimorphism confirming the statistically significant differences of volume between males and females and providing a method for the diagnosis of sex applicable to forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Application of artificial neural networks for the prediction of volume fraction using spectra of gamma rays backscattered by three-phase flows

    NASA Astrophysics Data System (ADS)

    Gholipour Peyvandi, R.; Islami Rad, S. Z.

    2017-12-01

    The determination of the volume fraction percentage of the different phases flowing in vessels using transmission gamma rays is a conventional method in petroleum and oil industries. In some cases, with access only to the one side of the vessels, attention was drawn toward backscattered gamma rays as a desirable choice. In this research, the volume fraction percentage was measured precisely in water-gasoil-air three-phase flows by using the backscatter gamma ray technique andthe multilayer perceptron (MLP) neural network. The volume fraction determination in three-phase flows requires two gamma radioactive sources or a dual-energy source (with different energies) while in this study, we used just a 137Cs source (with the single energy) and a NaI detector to analyze backscattered gamma rays. The experimental set-up provides the required data for training and testing the network. Using the presented method, the volume fraction was predicted with a mean relative error percentage less than 6.47%. Also, the root mean square error was calculated as 1.60. The presented set-up is applicable in some industries with limited access. Also, using this technique, the cost, radiation safety and shielding requirements are minimized toward the other proposed methods.

  14. Simple method for the generation of multiple homogeneous field volumes inside the bore of superconducting magnets.

    PubMed

    Chou, Ching-Yu; Ferrage, Fabien; Aubert, Guy; Sakellariou, Dimitris

    2015-07-17

    Standard Magnetic Resonance magnets produce a single homogeneous field volume, where the analysis is performed. Nonetheless, several modern applications could benefit from the generation of multiple homogeneous field volumes along the axis and inside the bore of the magnet. In this communication, we propose a straightforward method using a combination of ring structures of permanent magnets in order to cancel the gradient of the stray field in a series of distinct volumes. These concepts were demonstrated numerically on an experimentally measured magnetic field profile. We discuss advantages and limitations of our method and present the key steps required for an experimental validation.

  15. Modern Technology in Foreign Language Education: Applications and Projects. The ACTFL Foreign Language Education Series.

    ERIC Educational Resources Information Center

    Smith, Wm. Flint, Ed.

    This book, the second of two volumes devoted to instructional media in second language instruction, focuses on specific applications of advanced technology in the classroom. The first part, "Applications," contains seven chapters. They are: "The Language Laboratory in the Computer Age" (S. E. K. Otto); "Television…

  16. Development of a theoretical framework for analyzing cerebrospinal fluid dynamics

    PubMed Central

    Cohen, Benjamin; Voorhees, Abram; Vedel, Søren; Wei, Timothy

    2009-01-01

    Background To date hydrocephalus researchers acknowledge the need for rigorous but utilitarian fluid mechanics understanding and methodologies in studying normal and hydrocephalic intracranial dynamics. Pressure volume models and electric circuit analogs introduced pressure into volume conservation; but control volume analysis enforces independent conditions on pressure and volume. Previously, utilization of clinical measurements has been limited to understanding of the relative amplitude and timing of flow, volume and pressure waveforms; qualitative approaches without a clear framework for meaningful quantitative comparison. Methods Control volume analysis is presented to introduce the reader to the theoretical background of this foundational fluid mechanics technique for application to general control volumes. This approach is able to directly incorporate the diverse measurements obtained by clinicians to better elucidate intracranial dynamics and progression to disorder. Results Several examples of meaningful intracranial control volumes and the particular measurement sets needed for the analysis are discussed. Conclusion Control volume analysis provides a framework to guide the type and location of measurements and also a way to interpret the resulting data within a fundamental fluid physics analysis. PMID:19772652

  17. Analysis of volumetric response of pituitary adenomas receiving adjuvant CyberKnife stereotactic radiosurgery with the application of an exponential fitting model.

    PubMed

    Yu, Yi-Lin; Yang, Yun-Ju; Lin, Chin; Hsieh, Chih-Chuan; Li, Chiao-Zhu; Feng, Shao-Wei; Tang, Chi-Tun; Chung, Tzu-Tsao; Ma, Hsin-I; Chen, Yuan-Hao; Ju, Da-Tong; Hueng, Dueng-Yuan

    2017-01-01

    Tumor control rates of pituitary adenomas (PAs) receiving adjuvant CyberKnife stereotactic radiosurgery (CK SRS) are high. However, there is currently no uniform way to estimate the time course of the disease. The aim of this study was to analyze the volumetric responses of PAs after CK SRS and investigate the application of an exponential decay model in calculating an accurate time course and estimation of the eventual outcome.A retrospective review of 34 patients with PAs who received adjuvant CK SRS between 2006 and 2013 was performed. Tumor volume was calculated using the planimetric method. The percent change in tumor volume and tumor volume rate of change were compared at median 4-, 10-, 20-, and 36-month intervals. Tumor responses were classified as: progression for >15% volume increase, regression for ≤15% decrease, and stabilization for ±15% of the baseline volume at the time of last follow-up. For each patient, the volumetric change versus time was fitted with an exponential model.The overall tumor control rate was 94.1% in the 36-month (range 18-87 months) follow-up period (mean volume change of -43.3%). Volume regression (mean decrease of -50.5%) was demonstrated in 27 (79%) patients, tumor stabilization (mean change of -3.7%) in 5 (15%) patients, and tumor progression (mean increase of 28.1%) in 2 (6%) patients (P = 0.001). Tumors that eventually regressed or stabilized had a temporary volume increase of 1.07% and 41.5% at 4 months after CK SRS, respectively (P = 0.017). The tumor volume estimated using the exponential fitting equation demonstrated high positive correlation with the actual volume calculated by magnetic resonance imaging (MRI) as tested by Pearson correlation coefficient (0.9).Transient progression of PAs post-CK SRS was seen in 62.5% of the patients receiving CK SRS, and it was not predictive of eventual volume regression or progression. A three-point exponential model is of potential predictive value according to relative distribution. An exponential decay model can be used to calculate the time course of tumors that are ultimately controlled.

  18. Tire bales in highway applications : feasibility and properties evaluation

    DOT National Transportation Integrated Search

    2005-03-01

    There are growing interests in the utilization of recycled tire bales for civil engineering applications, triggered partly by the significant volumes of tires that could be disposed of in transportation projects. However, evaluation of tire bale prop...

  19. NASA Historical Data Book. Volume 6; NASA Space Applications, Aeronautics and Space Research and Technology, Tracking and Data Acquisition/Support Operations, Commercial Programs and

    NASA Technical Reports Server (NTRS)

    Rumerman, Judy A.

    2000-01-01

    This sixth volume of the NASA Historical Data Book is a continuation of those earlier efforts. This fundamental reference tool presents information, much of it statistical, documenting the development of several critical areas of NASA responsibility for the period between 1979 and 1988. This volume includes detailed information on the space applications effort, the development and operation of aeronautics and space research and technology programs, tracking and data acquisition/space operations, commercial programs, facilities and installations, personnel, and finances and procurement during this era. Special thanks are owed to the student research assistants who gathered and input much of the tabular material-a particularly tedious undertaking. There are numerous people at NASA associated with historical study, technical information, and the mechanics of publishing who helped in myriad ways in the preparation of this historical data book.

  20. Application of parallel distributed Lagrange multiplier technique to simulate coupled Fluid-Granular flows in pipes with varying Cross-Sectional area

    DOE PAGES

    Kanarska, Yuliya; Walton, Otis

    2015-11-30

    Fluid-granular flows are common phenomena in nature and industry. Here, an efficient computational technique based on the distributed Lagrange multiplier method is utilized to simulate complex fluid-granular flows. Each particle is explicitly resolved on an Eulerian grid as a separate domain, using solid volume fractions. The fluid equations are solved through the entire computational domain, however, Lagrange multiplier constrains are applied inside the particle domain such that the fluid within any volume associated with a solid particle moves as an incompressible rigid body. The particle–particle interactions are implemented using explicit force-displacement interactions for frictional inelastic particles similar to the DEMmore » method with some modifications using the volume of an overlapping region as an input to the contact forces. Here, a parallel implementation of the method is based on the SAMRAI (Structured Adaptive Mesh Refinement Application Infrastructure) library.« less

  1. Development and application of CATIA-GDML geometry builder

    NASA Astrophysics Data System (ADS)

    Belogurov, S.; Berchun, Yu; Chernogorov, A.; Malzacher, P.; Ovcharenko, E.; Schetinin, V.

    2014-06-01

    Due to conceptual difference between geometry descriptions in Computer-Aided Design (CAD) systems and particle transport Monte Carlo (MC) codes direct conversion of detector geometry in either direction is not feasible. The paper presents an update on functionality and application practice of the CATIA-GDML geometry builder first introduced at CHEP2010. This set of CATIAv5 tools has been developed for building a MC optimized GEANT4/ROOT compatible geometry based on the existing CAD model. The model can be exported via Geometry Description Markup Language (GDML). The builder allows also import and visualization of GEANT4/ROOT geometries in CATIA. The structure of a GDML file, including replicated volumes, volume assemblies and variables, is mapped into a part specification tree. A dedicated file template, a wide range of primitives, tools for measurement and implicit calculation of parameters, different types of multiple volume instantiation, mirroring, positioning and quality check have been implemented. Several use cases are discussed.

  2. Application of Control Volume Analysis to Cerebrospinal Fluid Dynamics

    NASA Astrophysics Data System (ADS)

    Wei, Timothy; Cohen, Benjamin; Anor, Tomer; Madsen, Joseph

    2011-11-01

    Hydrocephalus is among the most common birth defects and may not be prevented nor cured. Afflicted individuals face serious issues, which at present are too complicated and not well enough understood to treat via systematic therapies. This talk outlines the framework and application of a control volume methodology to clinical Phase Contrast MRI data. Specifically, integral control volume analysis utilizes a fundamental, fluid dynamics methodology to quantify intracranial dynamics within a precise, direct, and physically meaningful framework. A chronically shunted, hydrocephalic patient in need of a revision procedure was used as an in vivo case study. Magnetic resonance velocity measurements within the patient's aqueduct were obtained in four biomedical state and were analyzed using the methods presented in this dissertation. Pressure force estimates were obtained, showing distinct differences in amplitude, phase, and waveform shape for different intracranial states within the same individual. Thoughts on the physiological and diagnostic research and development implications/opportunities will be presented.

  3. Implicit theory manipulations affecting efficacy of a smartphone application aiding speech therapy for Parkinson's patients.

    PubMed

    Nolan, Peter; Hoskins, Sherria; Johnson, Julia; Powell, Vaughan; Chaudhuri, K Ray; Eglin, Roger

    2012-01-01

    A Smartphone speech-therapy application (STA) is being developed, intended for people with Parkinson's disease (PD) with reduced implicit volume cues. The STA offers visual volume feedback, addressing diminished auditory cues. Users are typically older adults, less familiar with new technology. Domain-specific implicit theories (ITs) have been shown to result in mastery or helpless behaviors. Studies manipulating participants' implicit theories of 'technology' (Study One), and 'ability to affect one's voice' (Study Two), were coordinated with iterative STA test-stages, using patients with PD with prior speech-therapist referrals. Across studies, findings suggest it is possible to manipulate patients' ITs related to engaging with a Smartphone STA. This potentially impacts initial application approach and overall effort using a technology-based therapy.

  4. Large-volume injection of sample diluents not miscible with the mobile phase as an alternative approach in sample preparation for bioanalysis: an application for fenspiride bioequivalence.

    PubMed

    Medvedovici, Andrei; Udrescu, Stefan; Albu, Florin; Tache, Florentin; David, Victor

    2011-09-01

    Liquid-liquid extraction of target compounds from biological matrices followed by the injection of a large volume from the organic layer into the chromatographic column operated under reversed-phase (RP) conditions would successfully combine the selectivity and the straightforward character of the procedure in order to enhance sensitivity, compared with the usual approach of involving solvent evaporation and residue re-dissolution. Large-volume injection of samples in diluents that are not miscible with the mobile phase was recently introduced in chromatographic practice. The risk of random errors produced during the manipulation of samples is also substantially reduced. A bioanalytical method designed for the bioequivalence of fenspiride containing pharmaceutical formulations was based on a sample preparation procedure involving extraction of the target analyte and the internal standard (trimetazidine) from alkalinized plasma samples in 1-octanol. A volume of 75 µl from the octanol layer was directly injected on a Zorbax SB C18 Rapid Resolution, 50 mm length × 4.6 mm internal diameter × 1.8 µm particle size column, with the RP separation being carried out under gradient elution conditions. Detection was made through positive ESI and MS/MS. Aspects related to method development and validation are discussed. The bioanalytical method was successfully applied to assess bioequivalence of a modified release pharmaceutical formulation containing 80 mg fenspiride hydrochloride during two different studies carried out as single-dose administration under fasting and fed conditions (four arms), and multiple doses administration, respectively. The quality attributes assigned to the bioanalytical method, as resulting from its application to the bioequivalence studies, are highlighted and fully demonstrate that sample preparation based on large-volume injection of immiscible diluents has an increased potential for application in bioanalysis.

  5. Diversity in general surgery: a period of progress.

    PubMed

    Andriole, Dorothy A; Klingensmith, Mary E; Schechtman, Kenneth B

    2005-01-01

    Although 1996 to 2002 was a period of declining interest in general surgery (GS) among U.S. medical students (USS), most categorical general surgery (C-GS) training positions offered in the National Residency Matching Program (NRMP) continued to fill. We measured the impact of the decreasing U.S. student applicant volume on C-GS match outcomes and GS resident workforce composition over this time period. Match outcomes were analyzed for 7 applicant categories. Subsequent GS resident workforce compositions were analyzed for proportions of U.S. allopathic medical school graduates (USG), osteopathic medical graduates (OMG), Canadian MG (CMG), foreign MG (FMG), female physicians, and African-American physicians. Mantel-Haenzel chi-square tests measured trends in match percentages, C-GS positions filled, and GS workforce composition. All p-values are 2-sided. Increasing match percentages for USS applicants (p < 0.0001) and USG (p = 0.001), with a decreasing percentage of C-GS positions filled by these applicants (p < 0.0001), were from declining applicant volumes. Increasing match percentage for non-U.S. allopathic medical applicants reflected increases in both applicant volumes and matched applicants, with an increasing percentage of C-GS positions filled by these applicants (p < 0.0001). The subsequent resident workforce included increasing proportions of FMGs and OMGs (each p < 0.001); proportions of USG MDs and CMGs decreased (p < 0.0001 and p < 0.02, respectively). Concurrently, there were increasing numbers and proportions of female physicians (p < 0.0001) and African-American physicians (p < 0.0001) in the general surgery resident workforce. Declining interest among U.S. students in GS has resulted in a workforce comprised of residents from a broad range of educational backgrounds, but also it has provided an opportunity for progress toward achievement of a GS resident physician workforce more equitably representative of the racial and gender composition of our society at large.

  6. Techniques for simulating flood hydrographs and estimating flood volumes for ungaged basins in east and west Tennessee

    USGS Publications Warehouse

    Gamble, C.R.

    1989-01-01

    A dimensionless hydrograph developed for a variety of basin conditions in Georgia was tested for its applicability to streams in East and West Tennessee by comparing it to a similar dimensionless hydrograph developed for streams in East and West Tennessee. Hydrographs of observed discharge at 83 streams in East Tennessee and 38 in West Tennessee were used in the study. Statistical analyses were performed by comparing simulated (or computed) hydrographs, derived by application of the Georgia dimensionless hydrograph, and dimensionless hydrographs developed from Tennessee data, with the observed hydrographs at 50 and 75% of their peak-flow widths. Results of the tests indicate that the Georgia dimensionless hydrography is virtually the same as the one developed for streams in East Tennessee, but that it is different from the dimensionless hydrograph developed for streams in West Tennessee. Because of the extensive testing of the Georgia dimensionless hydrograph, it was determined to be applicable for East Tennessee, whereas the dimensionless hydrograph developed from data on streams in West Tennessee was determined to be applicable in West Tennessee. As part of the dimensionless hydrograph development, an average lagtime in hours for each study basin, and the volume in inches of flood runoff for each flood event were computed. By use of multiple-regression analysis, equations were developed that relate basin lagtime to drainage area size, basin length, and percent impervious area. Similarly, flood volumes were related to drainage area size, peak discharge, and basin lagtime. These equations, along with the appropriate dimensionless hydrograph, can be used to estimate a typical (average) flood hydrograph and volume for recurrence-intervals up to 100 years at any ungaged site draining less than 50 sq mi in East and West Tennessee. (USGS)

  7. Assessing the Clinical Role of Genetic Markers of Early-Onset Prostate Cancer Among High-Risk Men Enrolled in Prostate Cancer Early Detection

    PubMed Central

    Hughes, Lucinda; Zhu, Fang; Ross, Eric; Gross, Laura; Uzzo, Robert G.; Chen, David Y. T.; Viterbo, Rosalia; Rebbeck, Timothy R.; Giri, Veda N.

    2011-01-01

    Background Men with familial prostate cancer (PCA) and African American men are at risk for developing PCA at younger ages. Genetic markers predicting early-onset PCA may provide clinically useful information to guide screening strategies for high-risk men. We evaluated clinical information from six polymorphisms associated with early-onset PCA in a longitudinal cohort of high-risk men enrolled in PCA early detection with significant African American participation. Methods Eligibility criteria include ages 35–69 with a family history of PCA or African American race. Participants undergo screening and biopsy per study criteria. Six markers associated with early-onset PCA (rs2171492 (7q32), rs6983561 (8q24), rs10993994 (10q11), rs4430796 (17q12), rs1799950 (17q21), and rs266849 (19q13)) were genotyped. Cox models were used to evaluate time to PCA diagnosis and PSA prediction for PCA by genotype. Harrell’s concordance index was used to evaluate predictive accuracy for PCA by PSA and genetic markers. Results 460 participants with complete data and ≥1 follow-up visit were included. 56% were African American. Among African American men, rs6983561 genotype was significantly associated with earlier time to PCA diagnosis (p=0.005) and influenced prediction for PCA by the PSA (p<0.001). When combined with PSA, rs6983561 improved predictive accuracy for PCA compared to PSA alone among African American men (PSA= 0.57 vs. PSA+rs6983561=0.75, p=0.03). Conclusions Early-onset marker rs6983561 adds potentially useful clinical information for African American men undergoing PCA risk assessment. Further study is warranted to validate these findings. Impact Genetic markers of early-onset PCA have potential to refine and personalize PCA early detection for high-risk men. PMID:22144497

  8. Proceedings of the 1993 Conference on Intelligent Computer-Aided Training and Virtual Environment Technology

    NASA Technical Reports Server (NTRS)

    Hyde, Patricia R.; Loftin, R. Bowen

    1993-01-01

    The volume 2 proceedings from the 1993 Conference on Intelligent Computer-Aided Training and Virtual Environment Technology are presented. Topics discussed include intelligent computer assisted training (ICAT) systems architectures, ICAT educational and medical applications, virtual environment (VE) training and assessment, human factors engineering and VE, ICAT theory and natural language processing, ICAT military applications, VE engineering applications, ICAT knowledge acquisition processes and applications, and ICAT aerospace applications.

  9. New municipal solid waste processing technology reduces volume and provides beneficial reuse applications for soil improvement and dust control

    USDA-ARS?s Scientific Manuscript database

    A garbage-processing technology has been developed that shreds, sterilizes, and separates inorganic and organic components of municipal solid waste. The technology not only greatly reduces waste volume, but the non-composted byproduct of this process, Fluff®, has the potential to be utilized as a s...

  10. Influence of Lumber Volume Maximization in Sawing Hardwood Sawlogs

    Treesearch

    Philip H. Steele; Francis G. Wagner; Lalit Kumar; Philip A. Araman

    1993-01-01

    The Best Opening Face (BOF) technology for volume maximization during sawing has been rapidly adopted by softwood sawmills. Application of this technology in hardwood sawmills has been limited because of their emphasis on sawing for the highest possible grade of lumber. The reason for this emphasis is that there is a relatively large difference in price between the...

  11. 40 CFR 80.1507 - What are the defenses for acts prohibited under this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Requirements for Gasoline-Ethanol Blends § 80.1507 What are the defenses for acts prohibited under this subpart... applicable maximum and/or minimum volume percent of ethanol. (2) That on each occasion when gasoline is found... checks to reconcile volumes of ethanol in inventory and regular checks of equipment for proper ethanol...

  12. 40 CFR 80.1507 - What are the defenses for acts prohibited under this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Requirements for Gasoline-Ethanol Blends § 80.1507 What are the defenses for acts prohibited under this subpart... applicable maximum and/or minimum volume percent of ethanol. (2) That on each occasion when gasoline is found... checks to reconcile volumes of ethanol in inventory and regular checks of equipment for proper ethanol...

  13. 40 CFR 80.1507 - What are the defenses for acts prohibited under this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Requirements for Gasoline-Ethanol Blends § 80.1507 What are the defenses for acts prohibited under this subpart... applicable maximum and/or minimum volume percent of ethanol. (2) That on each occasion when gasoline is found... checks to reconcile volumes of ethanol in inventory and regular checks of equipment for proper ethanol...

  14. Engineering Drawing Practices - Volume I of II: Aerospace and Ground Support Equipment

    NASA Technical Reports Server (NTRS)

    Schwindt, Paul A.

    2015-01-01

    This manual establishes the essential requirements and reference documents for the preparation and revision of digital product definition data sets prepared for or by NASA at KSC. This volume is only applicable to KSC in-house programs/projects. These requirements do not apply to the preparation of illustrations, artwork, or figures in technical publications.

  15. The Entrepreneurial Domains of American Higher Education. ASHE Higher Education Report, Volume 34, Number 5

    ERIC Educational Resources Information Center

    Mars, Matthew M.; Metcalf, Amy Scott

    2009-01-01

    This volume draws on a diverse set of literatures to represent the various ways in which entrepreneurship is understood in and applied to higher education. It provides a platform for debate for those considering applications of entrepreneurial principles to academic research and practices. Using academic entrepreneurship in the United States as…

  16. Specific gravity and other properties of wood and bark for 156 tree species found in North America

    Treesearch

    Patrick D. Miles

    2009-01-01

    This paper reports information for the estimation of biomass for 156 tree species found in North America for use in national forest inventory applications. We present specific gravities based on average green volume as well as 12 percent moisture content volume for calculation of oven-dry biomass....

  17. Improve forest inventory with access data-measure transport distance and cost to market.

    Treesearch

    Dennis P. Bradley

    1972-01-01

    Describes a method for relating forest inventory volumes to transport distances and costs. The process, originally developed in Sweden, includes a computer program that can be used to summarize volumes by transport costs per cord to specified delivery point. The method has many potential applications in all aspects of resource analysis.

  18. 30 CFR 260.114 - How does MMS assign and monitor royalty suspension volumes for eligible leases?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... have specified the water depth category for each eligible lease in the final Notice of OCS Lease Sale... OCS Lease Sale Package is available on the MMS Web site. Our determination of water depth for each... royalty suspension volume applicable to each water depth. The following table shows the royalty suspension...

  19. 40 CFR 89.207 - Credit calculation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) × (Volume) × (AvgPR) × (UL) × (Adjustment) × (10−6) (ii) For determining credit usage for all engine...) × (Volume) × (AvgPR) × (UL) × (10−6) Where: Std = the applicable Tier 1 NOX nonroad engine emission standard... for end-of-year compliance determination. AvgPR = the average power rating of all of the...

  20. Outside-bark form class volume tables for some southern Appalachian species

    Treesearch

    Jesse H. Buell

    1942-01-01

    Board-foot volume tables applicable to restricted localities are in continual demand. Pulic foresters need local tables for use on lands under their supervision or for helping farmers and other owners of small woodlands to prepae forest management plans. Privatr foresteres need tables which wil give dependable results in a wide variety of stands.

  1. 29 CFR 779.322 - Second requirement for qualifying as a “retail or service establishment.”

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... concept is applicable then the second requirement for qualifying as a “retail or service establishment” within that term's statutory definition is that 75 percent of the establishment's annual dollar volume... 75 percent of annual dollar volume be from sales of goods or services “not for resale” (§ 779.329...

  2. Field evaluation of indoor thermal fog and ultra-low volume applications for control of Aedes aegypti, in Thailand

    USDA-ARS?s Scientific Manuscript database

    Efficacies of a hand-held thermal fogger (PatriotTM) and hand-held Ultra-low volume (ULV) sprayer (TwisterTM) with combinations of two different adulticides and an insect growth regulator (pyriproxyfen) were field assessed and compared for their impact on reducing dengue vector populations in Thaila...

  3. Youth Advocacy Training Resource. Volume IV. A Review of Theory and Applications for the Education of Troubled Youth.

    ERIC Educational Resources Information Center

    Evaluation Technologies, Inc., Arlington, VA.

    This volume serves as a source of information about the relationship of Teacher Corps Youth Advocacy Project activities to the field of secondary school reform for troubled youth. This document presents major theories about educating troubled youth, theoretically-based programs, and research and evaluation on their effectiveness. Theories are…

  4. Vision '90: The Maricopa Community Colleges Journal of Teaching and Learning, Volume 2, Numbers 1-2, 1990.

    ERIC Educational Resources Information Center

    Malena, Richard F., Ed.

    1990-01-01

    Designed to provide a forum for faculty and staff in the Maricopa Community College District to exchange information about effective teaching methods for practical application and intellectual stimulation, this journal publishes articles on teaching, learning, and classroom research activities. The two issues in this volume contain the following…

  5. 78 FR 49411 - Denial of Petitions for Reconsideration of Regulation of Fuels and Fuel Additives: 2013 Biomass...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ...-AR55 Denial of Petitions for Reconsideration of Regulation of Fuels and Fuel Additives: 2013 Biomass... Fuel Additives: 2013 Biomass-Based Diesel Renewable Fuel Volume. DATES: EPA's denials of the petitions... requires that EPA determine the applicable volume of biomass-based diesel to be used in setting annual...

  6. NASA Propulsion Engineering Research Center, Volume 2

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This is the second volume in the 1994 annual report for the NASA Propulsion Engineering Research Center's Sixth Annual Symposium. This conference covered: (1) Combustors and Nozzles; (2) Turbomachinery Aero- and Hydro-dynamics; (3) On-board Propulsion systems; (4) Advanced Propulsion Applications; (5) Vaporization and Combustion; (6) Heat Transfer and Fluid Mechanics; and (7) Atomization and Sprays.

  7. Federal Student Aid Handbook, 2006-2007. Volume 1: Student Eligibility

    ERIC Educational Resources Information Center

    US Department of Education, 2006

    2006-01-01

    There are many factors to be considered when reviewing a student's application for aid from the FSA programs, such as whether the student is a U.S. citizen or permanent resident, whether the student is making satisfactory academic progress, and whether the student has a defaulted FSA loan. This volume of the Federal Student Aid Handbook discusses…

  8. EVALUATION OF THE REAL-TIME AIR-QUALITY MODEL USING THE RAPS (REGIONAL AIR POLLUTION STUDY) DATA BASE. VOLUME 3. PROGRAM USER'S GUIDE

    EPA Science Inventory

    The theory and programming of statistical tests for evaluating the Real-Time Air-Quality Model (RAM) using the Regional Air Pollution Study (RAPS) data base are fully documented in four volumes. Moreover, the tests are generally applicable to other model evaluation problems. Volu...

  9. EVALUATION OF THE REAL-TIME AIR-QUALITY MODEL USING THE RAPS (REGIONAL AIR POLLUTION STUDY) DATA BASE. VOLUME 4. EVALUATION GUIDE

    EPA Science Inventory

    The theory and programming of statistical tests for evaluating the Real-Time Air-Quality Model (RAM) using the Regional Air Pollution Study (RAPS) data base are fully documented in four volumes. Moreover, the tests are generally applicable to other model evaluation problems. Volu...

  10. 30 CFR 553.14 - How do I determine the worst case oil-spill discharge volume?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 2 2012-07-01 2012-07-01 false How do I determine the worst case oil-spill... THE INTERIOR OFFSHORE OIL SPILL FINANCIAL RESPONSIBILITY FOR OFFSHORE FACILITIES Applicability and Amount of OSFR § 553.14 How do I determine the worst case oil-spill discharge volume? (a) To calculate...

  11. 30 CFR 553.14 - How do I determine the worst case oil-spill discharge volume?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 2 2013-07-01 2013-07-01 false How do I determine the worst case oil-spill... THE INTERIOR OFFSHORE OIL SPILL FINANCIAL RESPONSIBILITY FOR OFFSHORE FACILITIES Applicability and Amount of OSFR § 553.14 How do I determine the worst case oil-spill discharge volume? (a) To calculate...

  12. 30 CFR 553.14 - How do I determine the worst case oil-spill discharge volume?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 2 2014-07-01 2014-07-01 false How do I determine the worst case oil-spill... THE INTERIOR OFFSHORE OIL SPILL FINANCIAL RESPONSIBILITY FOR OFFSHORE FACILITIES Applicability and Amount of OSFR § 553.14 How do I determine the worst case oil-spill discharge volume? (a) To calculate...

  13. A fault-tolerant multiprocessor architecture for aircraft, volume 1. [autopilot configuration

    NASA Technical Reports Server (NTRS)

    Smith, T. B.; Hopkins, A. L.; Taylor, W.; Ausrotas, R. A.; Lala, J. H.; Hanley, L. D.; Martin, J. H.

    1978-01-01

    A fault-tolerant multiprocessor architecture is reported. This architecture, together with a comprehensive information system architecture, has important potential for future aircraft applications. A preliminary definition and assessment of a suitable multiprocessor architecture for such applications is developed.

  14. Connection between encounter volume and diffusivity in geophysical flows

    NASA Astrophysics Data System (ADS)

    Rypina, Irina I.; Smith, Stefan G. Llewellyn; Pratt, Larry J.

    2018-04-01

    Trajectory encounter volume - the volume of fluid that passes close to a reference fluid parcel over some time interval - has been recently introduced as a measure of mixing potential of a flow. Diffusivity is the most commonly used characteristic of turbulent diffusion. We derive the analytical relationship between the encounter volume and diffusivity under the assumption of an isotropic random walk, i.e., diffusive motion, in one and two dimensions. We apply the derived formulas to produce maps of encounter volume and the corresponding diffusivity in the Gulf Stream region of the North Atlantic based on satellite altimetry, and discuss the mixing properties of Gulf Stream rings. Advantages offered by the derived formula for estimating diffusivity from oceanographic data are discussed, as well as applications to other disciplines.

  15. Liquid volume monitoring based on ultrasonic sensor and Arduino microcontroller

    NASA Astrophysics Data System (ADS)

    Husni, M.; Siahaan, D. O.; Ciptaningtyas, H. T.; Studiawan, H.; Aliarham, Y. P.

    2016-04-01

    Incident of oil leakage and theft in oil tank often happens. To prevent it, the liquid volume insides the tank needs to be monitored continuously. Aim of the study is to calculate the liquid volume inside oil tank on any road condition and send the volume data and location data to the user. This research use some ultrasonic sensors (to monitor the fluid height), Bluetooth modules (to sent data from the sensors to the Arduino microcontroller), Arduino Microcontroller (to calculate the liquid volume), and also GPS/GPRS/GSM Shield module (to get location of vehicle and sent the data to the Server). The experimental results show that the accuracy rate of monitoring liquid volume inside tanker while the vehicle is in the flat road is 99.33% and the one while the vehicle is in the road with elevation angle is 84%. Thus, this system can be used to monitor the tanker position and the liquid volume in any road position continuously via web application to prevent illegal theft.

  16. A numerical study of the phase behaviors of drug particle/star triblock copolymer mixtures in dilute solutions for drug carrier application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Shanhui; Tong, Chaohui; Zhu, Yuejin, E-mail: zhuyuejin@nbu.edu.cn

    The complex microstructures of drug particle/ABA star triblock copolymer in dilute solutions have been investigated by a theoretical approach which combines the self-consistent field theory and the hybrid particle-field theory. Simulation results reveal that, when the volume fraction of drug particles is smaller than the saturation concentration, the drug particle encapsulation efficiency is 100%, and micelle loading capacity increases with increasing particle volume fraction. When the volume fraction of drug particles is equal to the saturation concentration, the micelles attain the biggest size, and micelle loading capacity reaches a maximum value which is independent of the copolymer volume fraction. Whenmore » the volume fraction of drug particles is more than the saturation concentration, drug particle encapsulation efficiency decreases with increasing volume fraction of drug particles. Furthermore, it is found that the saturation concentration scales linearly with the copolymer volume fraction. The above simulation results are in good agreement with experimental results.« less

  17. Effects of solution volume on hydrogen production by pulsed spark discharge in ethanol solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xin, Y. B.; Sun, B., E-mail: sunb88@dlmu.edu.cn; Zhu, X. M.

    2016-07-15

    Hydrogen production from ethanol solution (ethanol/water) by pulsed spark discharge was optimized by varying the volume of ethanol solution (liquid volume). Hydrogen yield was initially increased and then decreased with the increase in solution volume, which achieved 1.5 l/min with a solution volume of 500 ml. The characteristics of pulsed spark discharge were studied in this work; the results showed that the intensity of peak current, the rate of current rise, and energy efficiency of hydrogen production can be changed by varying the volume of ethanol solution. Meanwhile, the mechanism analysis of hydrogen production was accomplished by monitoring the process of hydrogenmore » production and the state of free radicals. The analysis showed that decreasing the retention time of gas production and properly increasing the volume of ethanol solution can enhance the hydrogen yield. Through this research, a high-yield and large-scale method of hydrogen production can be achieved, which is more suitable for industrial application.« less

  18. Syntheses of the current model applications for managing water and needs for experimental data and model improvements to enhance these applications

    USDA-ARS?s Scientific Manuscript database

    This volume of the Advances in Agricultural Systems Modeling series presents 14 different case studies of model applications to help make the best use of limited water in agriculture. These examples show that models have tremendous potential and value in enhancing site-specific water management for ...

  19. Satellite provided customer premise services: A forecast of potential domestic demand through the year 2000. Volume 3: Appendices

    NASA Technical Reports Server (NTRS)

    Kratochvil, D.; Bowyer, J.; Bhushan, C.; Steinnagel, K.; Kaushal, D.; Al-Kinani, G.

    1983-01-01

    Voice applications, data applications, video applications, impacted baseline forecasts, market distribution, potential CPS (customers premises services) user classes, net long haul forecasts, CPS cost analysis, overall satellite forecast, CPS satellite market, Ka-band CPS satellite forecast, nationwide traffic distribution model, and intra-urban topology are discussed.

  20. Satellite provided customer premise services: A forecast of potential domestic demand through the year 2000. Volume 3: Appendices

    NASA Astrophysics Data System (ADS)

    Kratochvil, D.; Bowyer, J.; Bhushan, C.; Steinnagel, K.; Kaushal, D.; Al-Kinani, G.

    1983-08-01

    Voice applications, data applications, video applications, impacted baseline forecasts, market distribution, potential CPS (customers premises services) user classes, net long haul forecasts, CPS cost analysis, overall satellite forecast, CPS satellite market, Ka-band CPS satellite forecast, nationwide traffic distribution model, and intra-urban topology are discussed.

  1. 120 Hz pulse tube cryocooler for fast cooldown to 50 K

    NASA Astrophysics Data System (ADS)

    Vanapalli, Srinivas; Lewis, Michael; Gan, Zhihua; Radebaugh, Ray

    2007-02-01

    A pulse tube cryocooler operating at 120Hz with 3.5MPa average pressure achieved a no-load temperature of about 49.9K and a cooldown time to 80K of 5.5min. The net refrigeration power at 80K was 3.35W with an efficiency of 19.7% of Carnot when referred to input pressure-volume (PV or acoustic) power. Such low temperatures have not been previously achieved for operating frequencies above 100Hz. The high frequency operation leads to reduced cryocooler volume for a given refrigeration power, which is important to many applications and can enable development of microcryocoolers for microelectromechanical system applications.

  2. Optical designs for MWIR and four quadrant detectors by using beam steering methods in missile applications

    NASA Astrophysics Data System (ADS)

    Sakarya, Doǧan Uǧur

    2017-10-01

    Beam steering optical arrangement needs less volume envelope for same field of regard than other gimbal approaches. Both for imaging and four quadrant missile applications, volume is critical parameter limiting system performance. Therefore, a conceptual design of beam steering method has been focused on both imaging and four quadrant missiles. In this study; four different optical designs have been made by using both beam steering and regular method for mid-wave infra-red imaging and four quadrant systems. Optical designs performances have been illustrated in simulation results. By using manufactured Risley prisms, some experimental results are conducted to compare simulations results.

  3. Measuring impedance in congestive heart failure: Current options and clinical applications

    PubMed Central

    Tang, W. H. Wilson; Tong, Wilson

    2011-01-01

    Measurement of impedance is becoming increasingly available in the clinical setting as a tool for assessing hemodynamics and volume status in patients with heart failure. The 2 major categories of impedance assessment are the band electrode method and the implanted device lead method. The exact sources of the impedance signal are complex and can be influenced by physiologic effects such as blood volume, fluid, and positioning. This article provides a critical review of our current understanding and promises of impedance measurements, the techniques that have evolved, as well as the evidence and limitations regarding their clinical applications in the setting of heart failure management. PMID:19249408

  4. Hydrogen Storage for Aircraft Applications Overview

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Kohout, Lisa (Technical Monitor)

    2002-01-01

    Advances in fuel cell technology have brought about their consideration as sources of power for aircraft. This power can be utilized to run aircraft systems or even provide propulsion power. One of the key obstacles to utilizing fuel cells on aircraft is the storage of hydrogen. An overview of the potential methods of hydrogen storage was compiled. This overview identifies various methods of hydrogen storage and points out their advantages and disadvantages relative to aircraft applications. Minimizing weight and volume are the key aspects to storing hydrogen within an aircraft. An analysis was performed to show how changes in certain parameters of a given storage system affect its mass and volume.

  5. A scenario and forecast model for Gulf of Mexico hypoxic area and volume

    USGS Publications Warehouse

    Scavia, Donald; Evans, Mary Anne; Obenour, Daniel R.

    2013-01-01

    For almost three decades, the relative size of the hypoxic region on the Louisiana-Texas continental shelf has drawn scientific and policy attention. During that time, both simple and complex models have been used to explore hypoxia dynamics and to provide management guidance relating the size of the hypoxic zone to key drivers. Throughout much of that development, analyses had to accommodate an apparent change in hypoxic sensitivity to loads and often cull observations due to anomalous meteorological conditions. Here, we describe an adaptation of our earlier, simple biophysical model, calibrated to revised hypoxic area estimates and new hypoxic volume estimates through Bayesian estimation. This application eliminates the need to cull observations and provides revised hypoxic extent estimates with uncertainties, corresponding to different nutrient loading reduction scenarios. We compare guidance from this model application, suggesting an approximately 62% nutrient loading reduction is required to reduce Gulf hypoxia to the Action Plan goal of 5,000 km2, to that of previous applications. In addition, we describe for the first time, the corresponding response of hypoxic volume. We also analyze model results to test for increasing system sensitivity to hypoxia formation, but find no strong evidence of such change.

  6. Animal health pharmaceutical industry.

    PubMed

    Carnevale, Richard A; Shryock, Thomas R

    2006-02-24

    The animal health pharmaceutical industry has proactively reported on the volumes of member company antimicrobial active ingredients sold in the U.S. At the individual company level, reporting of finished product distribution data to the FDA is a regulatory requirement, with applications to surveillance and pharmacovigilance. An accounting of product manufactured is done for purposes of good business practices, as well as marketing analyses. Additional applications of antimicrobial usage data might include use in risk assessments, such as for the FDA's Center for Veterinary Medicine Guidance for Industry #152 for the evaluation of the microbiological safety of antimicrobials intended for use in food animals. Compilation of national usage data will be a complex undertaking, hindered by issues such as confidentiality, auditing, field use practice variations, population dynamics (e.g. disease incidence, market conditions for poultry and livestock production), and generic usage. The amounts or volumes in pounds should be considered relative to the large number of animals under husbandry in the United States. Large volumes might seem impressive unless put into proper context. Until such time as a clearly defined application of national usage data is agreed, it is recommended that local usage programs will provide more useful information to perpetuate prudent antimicrobial use in animals.

  7. Application of Medical Magnetic Resonance Imaging for Particle Concentration Measurement

    NASA Astrophysics Data System (ADS)

    Borup, Daniel; Elkins, Christopher; Eaton, John

    2014-11-01

    Particle transport and deposition in internal flows is important in a range of applications such as dust aggregation in turbine engines and aerosolized medicine deposition in human airways. Unlike optical techniques, Magnetic Resonance Imaging (MRI) is well suited for complex applications in which optical access is not possible. Here we present efforts to measure 3D particle concentration distribution using MRI. Glass particles dispersed in water flow reduce MRI signal from a spin-echo or gradient-echo scanning sequence by decreasing spin density and dephasing the spins present in the fluid. A preliminary experiment was conducted with a particle streak injected at the centerline of a turbulent round pipe flow with a U bend. Measurements confirmed that signal strength was related to particle concentration and showed the effects of gravitational settling and turbulent dispersion. Next, measurements of samples in a mixing chamber were taken. Particle volume fraction was varied and sensitivity to particle/fluid velocity was investigated. These results give a relationship between MRI signal, particle volume fraction, MRI sequence echo time, and spin relaxation parameters that can be used to measure local particle volume fraction in other turbulent flows of interest.

  8. High Productivity DRIE solutions for 3D-SiP and MEMS Volume Manufacturing

    NASA Astrophysics Data System (ADS)

    Puech, M.; Thevenoud, JM; Launay, N.; Arnal, N.; Godinat, P.; Andrieu, B.; Gruffat, JM

    2006-04-01

    Emerging 3D-SiP technologies and high volume MEMS applications require high productivity mass production DRIE systems. The Alcatel DRIE product range has recently been optimised to reach the highest process and hardware production performances. A study based on sub-micron high aspect ratio structures encountered in the most stringent 3D-SiP has been carried out. The optimization of the Bosch process parameters has resulted in ultra high silicon etch rates, with unrivalled uniformity and repeatability leading to excellent process. In parallel, most recent hardware and proprietary design optimization including vacuum pumping lines, process chamber, wafer chucks, pressure control system, gas delivery are discussed. These improvements have been monitored in a mass production environment for a mobile phone application. Field data analysis shows a significant reduction of cost of ownership thanks to increased throughput and much lower running costs. These benefits are now available for all 3D-SiP and high volume MEMS applications. The typical etched patterns include tapered trenches for CMOS imagers, through silicon via holes for die stacking, well controlled profile angle for 3D high precision inertial sensors, and large exposed area features for inkjet printer heads and Silicon microphones.

  9. Recovery Act: Oxy-Combustion Techology Development for Industrial-Scale Boiler Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levasseur, Armand

    2014-04-30

    Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: • Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs. • Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale testsmore » at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF). • Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools. • Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems. • Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost. • Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project completion date was April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxyprocess variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. The results from the 15 MWth testing in the BSF and complimentary bench-scale testing are addressed in this volume (Volume II) of the final report. The results of the modeling efforts (Volume III) and the oxy boiler design efforts (Volume IV) are reported in separate volumes.« less

  10. NASA Strategic Roadmap Committees Final Roadmaps. Volumes 1 and 2

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Volume 1 contains NASA strategic roadmaps for the following Advanced Planning and Integration Office (APIO) committees: Earth Science and Applications from Space; Sun - Solar System Connection. Volume 2 contains NASA strategic roadmaps for the following APIO committees: Robotic and Human Exploration of Mars; Solar System Exploration; Search for Earth-like Planets; Universe Exploration, as well as membership rosters and charters for all APIO committees, including those above and the following: Exploration Transportation System; Nuclear Systems; Robotic and Human Lunar Exploration; Aeronautical Technologies; Space Shuttle; International Space Station; Education.

  11. Modified Technique For Chemisorption Measurements

    NASA Technical Reports Server (NTRS)

    Schryer, David R.; Brown, Kenneth G.; Schryer, Jacqueline

    1989-01-01

    In measurements of chemisorption of CO on Pt/SnO2 catalyst observed that if small numbers of relatively large volumes of adsorbate gas are passed through sample, very little removal of CO detected. In these cases little or no CO has been chemisorbed on Pt/SnO2. Technique of using large number of small volumes of adsorbate gas to measure chemisorption applicable to many gas/material combinations other than CO on Pt/SnO2. Volume used chosen so that at least 10 percent of adsorbate gas removed during each exposure.

  12. Simple method for the generation of multiple homogeneous field volumes inside the bore of superconducting magnets

    PubMed Central

    Chou, Ching-Yu; Ferrage, Fabien; Aubert, Guy; Sakellariou, Dimitris

    2015-01-01

    Standard Magnetic Resonance magnets produce a single homogeneous field volume, where the analysis is performed. Nonetheless, several modern applications could benefit from the generation of multiple homogeneous field volumes along the axis and inside the bore of the magnet. In this communication, we propose a straightforward method using a combination of ring structures of permanent magnets in order to cancel the gradient of the stray field in a series of distinct volumes. These concepts were demonstrated numerically on an experimentally measured magnetic field profile. We discuss advantages and limitations of our method and present the key steps required for an experimental validation. PMID:26182891

  13. Phospholipid component volumes: determination and application to bilayer structure calculations.

    PubMed

    Armen, R S; Uitto, O D; Feller, S E

    1998-08-01

    We present a new method for the determination of bilayer structure based on a combination of computational studies and laboratory experiments. From molecular dynamics simulations, the volumes of submolecular fragments of saturated and unsaturated phosphatidylcholines in the liquid crystalline state have been extracted with a precision not available experimentally. Constancy of component volumes, both among different lipids and as a function of membrane position for a given lipid, have been examined. The component volumes were then incorporated into the liquid crystallographic method described by Wiener and White (1992. Biophys. J. 61:434-447, and references therein) for determining the structure of a fluid-phase dioleoylphosphatidylcholine bilayer from x-ray and neutron diffraction experiments.

  14. Phospholipid component volumes: determination and application to bilayer structure calculations.

    PubMed Central

    Armen, R S; Uitto, O D; Feller, S E

    1998-01-01

    We present a new method for the determination of bilayer structure based on a combination of computational studies and laboratory experiments. From molecular dynamics simulations, the volumes of submolecular fragments of saturated and unsaturated phosphatidylcholines in the liquid crystalline state have been extracted with a precision not available experimentally. Constancy of component volumes, both among different lipids and as a function of membrane position for a given lipid, have been examined. The component volumes were then incorporated into the liquid crystallographic method described by Wiener and White (1992. Biophys. J. 61:434-447, and references therein) for determining the structure of a fluid-phase dioleoylphosphatidylcholine bilayer from x-ray and neutron diffraction experiments. PMID:9675175

  15. Application of single-shot spiral scanning for volume localization.

    PubMed

    Ra, J B; Rim, C Y; Cho, Z H

    1991-02-01

    A new technique using a spiral scan single-shot RF pulse for localized volume selection has been developed and its experimental results are presented. This technique employs an additional radial-gradient coil in conjunction with the oscillating gradients for the spiral scan to localize the 3D volume. The short selection time in this technique minimizes both signal contamination from unwanted regions and signal attenuation due to T2 decay. We provide both the theoretical background of the technique and the experimental results obtained from a phantom as well as a human volunteer. The proposed method appears simple and accurate in localizing a volume which would be used as either fast imaging or localized spectroscopy.

  16. Review of Random Phase Encoding in Volume Holographic Storage

    PubMed Central

    Su, Wei-Chia; Sun, Ching-Cherng

    2012-01-01

    Random phase encoding is a unique technique for volume hologram which can be applied to various applications such as holographic multiplexing storage, image encryption, and optical sensing. In this review article, we first review and discuss diffraction selectivity of random phase encoding in volume holograms, which is the most important parameter related to multiplexing capacity of volume holographic storage. We then review an image encryption system based on random phase encoding. The alignment of phase key for decryption of the encoded image stored in holographic memory is analyzed and discussed. In the latter part of the review, an all-optical sensing system implemented by random phase encoding and holographic interconnection is presented.

  17. Microfluidic impact printer with interchangeable cartridges for versatile non-contact multiplexed micropatterning

    PubMed Central

    Ding, Yuzhe; Huang, Eric; Lam, Kit S.; Pan, Tingrui

    2015-01-01

    Biopatterning has been increasingly used for well-defined cellular microenvironment, patterned surface topology, and guided biological cues; however, it meets additional challenges on biocompatibility, temperature and chemical sensitivity and limited reagent volume. In this paper, we target at combining the desired features from the non-contact inkjet printing and the dot-matrix impact printing to establish a versatile multiplexed micropatterning platform, referred to as Microfluidic Impact Printer (MI-Printer), for emerging biomedical applications. Using this platform, we can achieve the distinct features of no cross-contamination, minute volume manipulation with minimal dead volume, high-throughput and biocompatible printing process, multiplexed patterning with automatic alignment, printing availability for complex medium (cell suspension or colloidal solutions), interchangeable/disposable microfluidic cartridge design with out-of-cleanroom microfabrication, simple printing system assembly and configuration, all highly desirable towards biological applications. Specifically, the printing resolution of the MI-printer platform has been experimentally characterized and theoretically analyzed. Printed droplets with 80µm in diameter have been repeatedly obtained. Furthermore, two unique features of MI-printer platform, multiplexed printing and self-alignment printing, have been successfully experimentally demonstrated (less than 10µm misalignment). In addition, combinatorial patterning and biological patterning, which utilizes the multiplexed and self-alignment printing nature of the MI-printer, have been devised to demonstrate the applicability of this robust printing technique for emerging biomedical applications. PMID:23525299

  18. Applications of aerospace technology to petroleum exploration. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Jaffe, L. D.

    1976-01-01

    Participants in the investigation of problem areas in oil exploration are listed and the data acquisition methods used to determine categories to be studied are described. Specific aerospace techniques applicable to the tasks identified are explained and their costs evaluated.

  19. Stratal Control Volumes and Stratal Control Trajectories: A New Method to Constrain, Understand and Reconcile Results from Stratigraphic Outcrop Analysis, Subsurface Analysis and Analogue and Numerical Modelling

    NASA Astrophysics Data System (ADS)

    Burgess, P. M.; Steel, R. J.

    2016-12-01

    Decoding a history of Earth's surface dynamics from strata requires robust quantitative understanding of supply and accommodation controls. The concept of stratigraphic solution sets has proven useful in this decoding, but application and development of this approach has so far been surprisingly limited. Stratal control volumes, areas and trajectories are new approaches defined here, building on previous ideas about stratigraphic solution sets, to help analyse and understand the sedimentary record of Earth surface dynamics. They may have particular application reconciling results from outcrop and subsurface analysis with results from analogue and numerical experiments. Stratal control volumes are sets of points in a three-dimensional volume, with axes of subsidence, sediment supply and eustatic rates of change, populated with probabilities derived from analysis of subsidence, supply and eustasy timeseries (Figure 1). These empirical probabilities indicate the likelihood of occurrence of any particular combination of control rates defined by any point in the volume. The stratal control volume can then by analysed to determine which parts of the volume represent relative sea-level fall and rise, where in the volume particular stacking patterns will occur, and how probable those stacking patterns are. For outcrop and subsurface analysis, using a stratal control area with eustasy and subsidence combined on a relative sea-level axis allows similar analysis, and may be preferable. A stratal control trajectory is a history of supply and accommodation creation rates, interpreted from outcrop or subsurface data, or observed in analogue and numerical experiments, and plotted as a series of linked points forming a trajectory through the stratal control volume (Figure 1) or area. Three examples are presented, one from outcrop and two theoretical. Much work remains to be done to build a properly representative database of stratal controls, but careful comparison of stratal control volume and trajectories constructed from outcrop analysis, subsurface analysis and experimental models may help the convergence, reconciliation and future evolution of these different approaches.

  20. Integrated Power/Attitude Control System (IPACS) study. Volume 1: Feasibility studies. [application of flywheels for power storage and generation

    NASA Technical Reports Server (NTRS)

    Notti, J. E.; Cormack, A., III; Schmill, W. C.

    1974-01-01

    An Integrated Power/Attitude Control System (IPACS) concept consisting of an array of spinning flywheels, with or without gimbals, capable of performing the dual function of power storage and generation, as well as attitude control has been investigated. This system provides attitude control through momentum storage, and replaces the storage batteries onboard the spacecraft. The results of the investigation are presented in two volumes. The trade-off studies performed to establish the feasibility, cost effectiveness, required level of development, and boundaries of application of IPACS to a wide variety of spacecraft are discussed. The conceptual designs for a free-flying research application module (RAM), and for a tracking and data relay satellite (TDRS) are presented. Results from dynamic analyses and simulations of the IPACS conceptual designs are included.

  1. Photopolymerizable nanocomposite photonic materials and their holographic applications in light and neutron optics

    PubMed Central

    Tomita, Yasuo; Hata, Eiji; Momose, Keisuke; Takayama, Shingo; Liu, Xiangming; Chikama, Katsumi; Klepp, Jürgen; Pruner, Christian; Fally, Martin

    2016-01-01

    We present an overview of recent investigations of photopolymerizable nanocomposite photonic materials in which, thanks to their high degree of material selectivity, recorded volume gratings possess high refractive index modulation amplitude and high mechanical/thermal stability at the same time, providing versatile applications in light and neutron optics. We discuss the mechanism of grating formation in holographically exposed nanocomposite materials, based on a model of the photopolymerization-driven mutual diffusion of monomer and nanoparticles. Experimental inspection of the recorded grating’s morphology by various physicochemical and optical methods is described. We then outline the holographic recording properties of volume gratings recorded in photopolymerizable nanocomposite materials consisting of inorganic/organic nanoparticles and monomers having various photopolymerization mechanisms. Finally, we show two examples of our holographic applications, holographic digital data storage and slow-neutron beam control. PMID:27594769

  2. COMO: a numerical model for predicting furnace performance in axisymmetric geometries. Volume 1. Technical summary. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fiveland, W.A.; Oberjohn, W.J.; Cornelius, D.K.

    1985-12-01

    This report summarizes the work conducted during a 30-month contract with the United States Department of Energy (DOE) Pittsburgh Energy Technology Center (PETC). The general objective is to develop and verify a computer code capable of modeling the major aspects of pulverized coal combustion. Achieving this objective will lead to design methods applicable to industrial and utility furnaces. The combustion model (COMO) is based mainly on an existing Babcock and Wilcox (B and W) computer program. The model consists of a number of relatively independent modules that represent the major processes involved in pulverized coal combustion: flow, heterogeneous and homogeneousmore » chemical reaction, and heat transfer. As models are improved or as new ones are developed, this modular structure allows portions of the COMO model to be updated with minimal impact on the remainder of the program. The report consists of two volumes. This volume (Volume 1) contains a technical summary of the COMO model, results of predictions for gas phase combustion, pulverized coal combustion, and a detailed description of the COMO model. Volume 2 is the Users Guide for COMO and contains detailed instructions for preparing the input data and a description of the program output. Several example cases have been included to aid the user in usage of the computer program for pulverized coal applications. 66 refs., 41 figs., 21 tabs.« less

  3. Self-evolving atomistic kinetic Monte Carlo simulations of defects in materials

    DOE PAGES

    Xu, Haixuan; Beland, Laurent K.; Stoller, Roger E.; ...

    2015-01-29

    The recent development of on-the-fly atomistic kinetic Monte Carlo methods has led to an increased amount attention on the methods and their corresponding capabilities and applications. In this review, the framework and current status of Self-Evolving Atomistic Kinetic Monte Carlo (SEAKMC) are discussed. SEAKMC particularly focuses on defect interaction and evolution with atomistic details without assuming potential defect migration/interaction mechanisms and energies. The strength and limitation of using an active volume, the key concept introduced in SEAKMC, are discussed. Potential criteria for characterizing an active volume are discussed and the influence of active volume size on saddle point energies ismore » illustrated. A procedure starting with a small active volume followed by larger active volumes was found to possess higher efficiency. Applications of SEAKMC, ranging from point defect diffusion, to complex interstitial cluster evolution, to helium interaction with tungsten surfaces, are summarized. A comparison of SEAKMC with molecular dynamics and conventional object kinetic Monte Carlo is demonstrated. Overall, SEAKMC is found to be complimentary to conventional molecular dynamics, especially when the harmonic approximation of transition state theory is accurate. However it is capable of reaching longer time scales than molecular dynamics and it can be used to systematically increase the accuracy of other methods such as object kinetic Monte Carlo. Furthermore, the challenges and potential development directions are also outlined.« less

  4. A method to combine target volume data from 3D and 4D planned thoracic radiotherapy patient cohorts for machine learning applications.

    PubMed

    Johnson, Corinne; Price, Gareth; Khalifa, Jonathan; Faivre-Finn, Corinne; Dekker, Andre; Moore, Christopher; van Herk, Marcel

    2018-02-01

    The gross tumour volume (GTV) is predictive of clinical outcome and consequently features in many machine-learned models. 4D-planning, however, has prompted substitution of the GTV with the internal gross target volume (iGTV). We present and validate a method to synthesise GTV data from the iGTV, allowing the combination of 3D and 4D planned patient cohorts for modelling. Expert delineations in 40 non-small cell lung cancer patients were used to develop linear fit and erosion methods to synthesise the GTV volume and shape. Quality was assessed using Dice Similarity Coefficients (DSC) and closest point measurements; by calculating dosimetric features; and by assessing the quality of random forest models built on patient populations with and without synthetic GTVs. Volume estimates were within the magnitudes of inter-observer delineation variability. Shape comparisons produced mean DSCs of 0.8817 and 0.8584 for upper and lower lobe cases, respectively. A model trained on combined true and synthetic data performed significantly better than models trained on GTV alone, or combined GTV and iGTV data. Accurate synthesis of GTV size from the iGTV permits the combination of lung cancer patient cohorts, facilitating machine learning applications in thoracic radiotherapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Estimating the carbon in coarse woody debris with perpendicular distance sampling. Chapter 6

    Treesearch

    Harry T. Valentine; Jeffrey H. Gove; Mark J. Ducey; Timothy G. Gregoire; Michael S. Williams

    2008-01-01

    Perpendicular distance sampling (PDS) is a design for sampling the population of pieces of coarse woody debris (logs) in a forested tract. In application, logs are selected at sample points with probability proportional to volume. Consequently, aggregate log volume per unit land area can be estimated from tallies of logs at sample points. In this chapter we provide...

  6. RESULTS FROM EPA FUNDED RESEARCH PROGRAMS ON THE IMPORTANCE OF PURGE VOLUME, SAMPLE VOLUME, SAMPLE FLOW RATE AND TEMPORAL VARIATIONS ON SOIL GAS CONCENTRATIONS

    EPA Science Inventory

    Two research studies funded and overseen by EPA have been conducted since October 2006 on soil gas sampling methods and variations in shallow soil gas concentrations with the purpose of improving our understanding of soil gas methods and data for vapor intrusion applications. Al...

  7. Impact Study on Driving by Special Populations. Final Report. Volume II: A Guide for the Evaluation of Handicapped Drivers.

    ERIC Educational Resources Information Center

    Brainin, Paul A.; And Others

    The second of a two-volume report on motor vehicle driving by handicapped persons presents an approach to the evaluation of drivers with 20 specific )edical problems. The guide provides information on symptoms, treatment, guidelines for determining risk levels (risk increasing and risk moderating factors), questions for the applicant, and…

  8. Exploring Young Children's Understanding about the Concept of Volume through Engineering Design in a STEM Activity: A Case Study

    ERIC Educational Resources Information Center

    Park, Do-Yong; Park, Mi-Hwa; Bates, Alan B.

    2018-01-01

    This case study explores young children's understanding and application of the concept of volume through the practices of engineering design in a STEM activity. STEM stands for science, technology, engineering, and mathematics. However, engineering stands out as a challenging area to implement. In addition, most early engineering education…

  9. Simulating double-peak hydrographs from single storms over mixed-use watersheds

    Treesearch

    Yang Yang; Theodore A. Endreny; David J. Nowak

    2015-01-01

    Two-peak hydrographs after a single rain event are observed in watersheds and storms with distinct volumes contributing as fast and slow runoff. The authors developed a hydrograph model able to quantify these separate runoff volumes to help in estimation of runoff processes and residence times used by watershed managers. The model uses parallel application of two...

  10. Educational Technology Project, Volume One. The Development of Materials for the Training of Science Education Personnel in Educational Technology. Final Report.

    ERIC Educational Resources Information Center

    Ziener, George H.; And Others

    The planning, production, validation, and revision of learning materials designed for use in institutes for science supervisors is described in this first of five volumes. Four sets of packages, ("Role of the Science Supervisor,""Introduction to Educational Technology,""An Application of Educational Technology," and "Management Kits,") each using…

  11. NRC/AMRMC Resident Research Associateship Program

    DTIC Science & Technology

    2016-04-27

    published in refereed journals 0 Patent applications 2 International presentations 52 Domestic presentations 6 Awards After ending their tenure...laboratory. 9) PUBLICATIONS AND PAPERS RESULTING FROM NRC ASSOCIATESHIP RESEARCH Provide complete citations: author(s), title, full name of journal , volume...ASSOCIATESHIP RESEARCH Provide complete citations: author(s), title, full name of journal , volume number, page number(s), and year of publication. a

  12. NRC/AMRMC Resident Research Associateship Program

    DTIC Science & Technology

    2016-04-01

    tenure. 28 Articles published in refereed journals 0 Patent applications 2 International presentations 52 Domestic presentations 6 Awards After... RESEARCH Provide complete citations: author(s), title, full name of journal , volume number, page number(s), and year of publication. a) Publications in peer...PUBLICATIONS AND PAPERS RESULTING FROM NRC ASSOCIATESHIP RESEARCH Provide complete citations: author(s), title, full name of journal , volume number, page

  13. 30 CFR 253.14 - How do I determine the worst case oil-spill discharge volume?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false How do I determine the worst case oil-spill... ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL SPILL FINANCIAL RESPONSIBILITY FOR OFFSHORE FACILITIES Applicability and Amount of OSFR § 253.14 How do I determine the worst case oil-spill discharge volume? (a) To...

  14. 30 CFR 253.14 - How do I determine the worst case oil-spill discharge volume?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I determine the worst case oil-spill... INTERIOR OFFSHORE OIL SPILL FINANCIAL RESPONSIBILITY FOR OFFSHORE FACILITIES Applicability and Amount of OSFR § 253.14 How do I determine the worst case oil-spill discharge volume? (a) To calculate the amount...

  15. Application of a Model for Quenching and Partitioning in Hot Stamping of High-Strength Steel

    NASA Astrophysics Data System (ADS)

    Zhu, Bin; Liu, Zhuang; Wang, Yanan; Rolfe, Bernard; Wang, Liang; Zhang, Yisheng

    2018-04-01

    Application of quenching and partitioning process in hot stamping has proven to be an effective method to improve the plasticity of advanced high-strength steels (AHSSs). In this study, the hot stamping and partitioning process of advanced high-strength steel 30CrMnSi2Nb is investigated with a hot stamping mold. Given the specific partitioning time and temperature, the influence of quenching temperature on the volume fraction of microstructure evolution and mechanical properties of the above steel are studied in detail. In addition, a model for quenching and partitioning process is applied to predict the carbon diffusion and interface migration during partitioning, which determines the retained austenite volume fraction and final properties of the part. The predicted trends of the retained austenite volume fraction agree with the experimental results. In both cases, the volume fraction of retained austenite increases first and then decreases with the increasing quenching temperature. The optimal quenching temperature is approximately 290 °C for 30CrMnSi2Nb with the partition conditions of 425 °C and 20 seconds. It is suggested that the model can be used to help determine the process parameters to obtain retained austenite as much as possible.

  16. Remote excitation fluorescence correlation spectroscopy using silver nanowires

    NASA Astrophysics Data System (ADS)

    Su, Liang; Yuan, Haifeng; Lu, Gang; Hofkens, Johan; Roeffaers, Maarten; Uji-i, Hiroshi

    2014-11-01

    Fluorescence correlation spectroscopy (FCS), a powerful tool to resolve local properties, dynamical process of molecules, rotational and translational diffusion motions, relies on the fluctuations of florescence observables in the observation volume. In the case of rare transition events or small dynamical fluctuations, FCS requires few molecules or even single molecules in the observation volume at a time to minimize the background signals. Metal nanoparticle which possess unique localized surface plasmon resonance (LSPR) have been used to reduce the observation volume down to sub-diffraction limited scale while maintain at high analyst concentration up to tens of micromolar. Nevertheless, the applications of functionalized nanoparticles in living cell are limited due to the continuous diffusion after cell uptake, which makes it difficult to target the region of interests in the cell. In this work, we demonstrate the use of silver nanowires for remote excitation FCS on fluorescent molecules in solution. By using propagation surface plasmon polaritons (SPPs) which supported by the silver nanowire to excite the fluorescence, both illumination and observation volume can be reduced simultaneously. In such a way, less perturbation is induced to the target region, and this will broaden the application scope of silver nanowire as tip in single cell endoscopy.

  17. Application of State Quantization-Based Methods in HEP Particle Transport Simulation

    NASA Astrophysics Data System (ADS)

    Santi, Lucio; Ponieman, Nicolás; Jun, Soon Yung; Genser, Krzysztof; Elvira, Daniel; Castro, Rodrigo

    2017-10-01

    Simulation of particle-matter interactions in complex geometries is one of the main tasks in high energy physics (HEP) research. An essential aspect of it is an accurate and efficient particle transportation in a non-uniform magnetic field, which includes the handling of volume crossings within a predefined 3D geometry. Quantized State Systems (QSS) is a family of numerical methods that provides attractive features for particle transportation processes, such as dense output (sequences of polynomial segments changing only according to accuracy-driven discrete events) and lightweight detection and handling of volume crossings (based on simple root-finding of polynomial functions). In this work we present a proof-of-concept performance comparison between a QSS-based standalone numerical solver and an application based on the Geant4 simulation toolkit, with its default Runge-Kutta based adaptive step method. In a case study with a charged particle circulating in a vacuum (with interactions with matter turned off), in a uniform magnetic field, and crossing up to 200 volume boundaries twice per turn, simulation results showed speedups of up to 6 times in favor of QSS while it being 10 times slower in the case with zero volume boundaries.

  18. Computer Assisted Rehabilitation Service Delivery.

    ERIC Educational Resources Information Center

    West Virginia Rehabilitation Research and Training Center, Dunbar.

    This volume consisting of state of the art reviews, suggestions and guidelines for practitioners, and program descriptions deals with the current and potential applications of computers in the delivery of services for vocational rehabilitation (VR). Discussed first are current applications of computer technology in rehabilitative service delivery.…

  19. Applications of Tethers in Space, Volume 1

    NASA Technical Reports Server (NTRS)

    Cron, A. C. (Compiler)

    1985-01-01

    The tethered satellite system is described including tether fundamentals. Applications of very long tethers in space to a broad spectrum of future space missions are explored. Topics covered include: science, transportation, constellations, artificial gravity, technology and test, and electrodynamic interactions. Recommendations to NASA are included.

  20. Ultra-low altitude and low spraying technology research with UAV in paddy

    USDA-ARS?s Scientific Manuscript database

    Aerial application has characteristics of low-volume, small droplet, and possibility of drift. To control rice planthopper, leaf roller and blast, the research aimed at screening agrichemicals and determining the feasibility of using high concentration of conventional dosage for aerial application....

  1. Projection display market trends

    NASA Astrophysics Data System (ADS)

    Mentley, David E.

    1997-05-01

    The projection display industry is now a multi-billion dollar market comprising an expanding variety of technologies and applications. Growth is being driven by a combination of high volume consumer products and high value business demand. After many years of marginal, but steady performance improvements, essentially all types of projectors have crossed the threshold of acceptability and are now facing accelerated continuing growth. Overall worldwide unit sales of all types of projection displays for all applications will nearly double from 1.6 million units in 1996 to 2.8 million units in 2002. By value at the end user price, the global projector market will grow modestly from 6.3 billion dollars in 1996 to 7.7 billion dollars in 2002. Consumer television will represent the largest share of unit consumption over this time period; in 1996, this application represents 72 percent of the total unit volume. The second major application category for projection displays is the business or presentation projector, representing only 14 percent of the unit shipment total in 1996, but 50 percent of the value.

  2. Effectiveness of indoor ultra-low volume application of Aqua Reslin® Super during an emergency.

    PubMed

    Ordóñez González, José Genaro; Thirion, Jaime; García Orozco, Abel; Rodríguez, Américo D

    2011-06-01

    Indoor ultra-low volume (ULV) applications of Aqua Reslin Super (Permethrin + s-bioallethrin) were carried out using portable Solo Port 423 sprayers in an urban area of Reforma, Chiapas, Mexico. Sprayers were calibrated to discharge a flow rate of 110 ml/min with a dose range of approximately 0.55 to 0.792 mg Al/m3 space. Entomological evaluation, based on 3 cages per house, each containing 15 sugar-fed, 2-4-day-old Aedes aegypti females and placed in hidden locations in 4 randomly selected houses for 15 min, showed 98.8% to 100% mortality. After the spraying, ovitrap data showed no mosquito adults present 4 days after the applications, and only 1 ovitrap out of 60 positive 8 days after the intervention. This evaluation suggests that indoor ULV application can be useful during emergencies after disasters, during dengue outbreaks, or to prevent mosquito population outbreaks before rainy seasons and, therefore, the onset of dengue transmission in Mexican dengue transmission risk areas.

  3. Electrical Capacitance Volume Tomography: Design and Applications

    PubMed Central

    Wang, Fei; Marashdeh, Qussai; Fan, Liang-Shih; Warsito, Warsito

    2010-01-01

    This article reports recent advances and progress in the field of electrical capacitance volume tomography (ECVT). ECVT, developed from the two-dimensional electrical capacitance tomography (ECT), is a promising non-intrusive imaging technology that can provide real-time three-dimensional images of the sensing domain. Images are reconstructed from capacitance measurements acquired by electrodes placed on the outside boundary of the testing vessel. In this article, a review of progress on capacitance sensor design and applications to multi-phase flows is presented. The sensor shape, electrode configuration, and the number of electrodes that comprise three key elements of three-dimensional capacitance sensors are illustrated. The article also highlights applications of ECVT sensors on vessels of various sizes from 1 to 60 inches with complex geometries. Case studies are used to show the capability and validity of ECVT. The studies provide qualitative and quantitative real-time three-dimensional information of the measuring domain under study. Advantages of ECVT render it a favorable tool to be utilized for industrial applications and fundamental multi-phase flow research. PMID:22294905

  4. Analysis and forecast of railway coal transportation volume based on BP neural network combined forecasting model

    NASA Astrophysics Data System (ADS)

    Xu, Yongbin; Xie, Haihong; Wu, Liuyi

    2018-05-01

    The share of coal transportation in the total railway freight volume is about 50%. As is widely acknowledged, coal industry is vulnerable to the economic situation and national policies. Coal transportation volume fluctuates significantly under the new economic normal. Grasp the overall development trend of railway coal transportation market, have important reference and guidance significance to the railway and coal industry decision-making. By analyzing the economic indicators and policy implications, this paper expounds the trend of the coal transportation volume, and further combines the economic indicators with the high correlation with the coal transportation volume with the traditional traffic prediction model to establish a combined forecasting model based on the back propagation neural network. The error of the prediction results is tested, which proves that the method has higher accuracy and has practical application.

  5. High definition in vivo retinal volumetric video rate OCT at 0.6 Giga-voxels per second

    NASA Astrophysics Data System (ADS)

    Kolb, Jan Philip; Klein, Thomas; Wieser, Wolfgang; Draxinger, Wolfgang; Huber, Robert

    2015-07-01

    We present full volumetric high speed OCT imaging of the retina with multiple settings varying in volume size and volume rate. The volume size ranges from 255x255 A-scans to 160x40 A-scans with 450 samples per depth scan with volume rates varying between 20.8 V/s for the largest volumes to 195.2 V/s for the smallest. The system is based on a 1060nm Fourier domain mode locked (FDML) laser with 1.6MHz line rate. Scanning along the fast axis is performed with a 2.7 kHz or 4.3 kHz resonant scanner operated in bidirectional scanning mode, while a standard galvo scanner is used for the slow axis. The performance is analyzed with respect to various potential applications, like intraoperative OCT.

  6. Improvement of the Correlative AFM and ToF-SIMS Approach Using an Empirical Sputter Model for 3D Chemical Characterization.

    PubMed

    Terlier, T; Lee, J; Lee, K; Lee, Y

    2018-02-06

    Technological progress has spurred the development of increasingly sophisticated analytical devices. The full characterization of structures in terms of sample volume and composition is now highly complex. Here, a highly improved solution for 3D characterization of samples, based on an advanced method for 3D data correction, is proposed. Traditionally, secondary ion mass spectrometry (SIMS) provides the chemical distribution of sample surfaces. Combining successive sputtering with 2D surface projections enables a 3D volume rendering to be generated. However, surface topography can distort the volume rendering by necessitating the projection of a nonflat surface onto a planar image. Moreover, the sputtering is highly dependent on the probed material. Local variation of composition affects the sputter yield and the beam-induced roughness, which in turn alters the 3D render. To circumvent these drawbacks, the correlation of atomic force microscopy (AFM) with SIMS has been proposed in previous studies as a solution for the 3D chemical characterization. To extend the applicability of this approach, we have developed a methodology using AFM-time-of-flight (ToF)-SIMS combined with an empirical sputter model, "dynamic-model-based volume correction", to universally correct 3D structures. First, the simulation of 3D structures highlighted the great advantages of this new approach compared with classical methods. Then, we explored the applicability of this new correction to two types of samples, a patterned metallic multilayer and a diblock copolymer film presenting surface asperities. In both cases, the dynamic-model-based volume correction produced an accurate 3D reconstruction of the sample volume and composition. The combination of AFM-SIMS with the dynamic-model-based volume correction improves the understanding of the surface characteristics. Beyond the useful 3D chemical information provided by dynamic-model-based volume correction, the approach permits us to enhance the correlation of chemical information from spectroscopic techniques with the physical properties obtained by AFM.

  7. Defense AT and L. Volume 42, Number 1

    DTIC Science & Technology

    2013-02-01

    Agnish The U.S. Army late last year began equipping brigade combat teams with its first package of radios, satellite systems, software applications...Army’s first package of radios, satellite systems, software applications, smartphone-like devices, and other network components that provide integrated... satellite communications, intelligence, mission command applications, and the integration of C4ISR equip- ment onto various vehicle platforms. This

  8. Instrumentation for Applied Physics and Industrial Applications

    NASA Astrophysics Data System (ADS)

    Hillemanns, H.; Le Goff, J.-M.

    This document is part of Part 2 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Section '7.3 Instrumentation for Applied Physics and Industrial Applications' of Chapter '7 Applications of Detectors in Technology; Medicine and Other Fields' with the content:

  9. Phosphorus transfer in runoff following application of fertilizer, manure, and sewage sludge.

    PubMed

    Withers, P J; Clay, S D; Breeze, V G

    2001-01-01

    Phosphorus (P) transfer in surface runoff from field plots receiving either no P, triplesuperphoshate (TSP), liquid cattle manure (LCS), liquid anaerobically digested sludge (LDS), or dewatered sludge cake (DSC) was compared over a 2-yr period. Dissolved inorganic P concentrations in runoff increased from 0.1 to 0.2 mg L(-1) on control and sludge-treated plots to 3.8 and 6.5 mg L(-1) following application of LCS and TSP, respectively, to a cereal crop in spring. When incorporated into the soil in autumn, runoff dissolved P concentrations were typically < 0.5 mg L(-1) across all plots, and particulate P remained the dominant P form. When surface-applied in autumn to a consolidated seedbed, direct loss of LCS and LDS increased both runoff volume and P transfers, but release of dissolved P occurred only from LCS. The largest P concentrations (>70 mg L(-1)) were recorded following TSP application without any increase in runoff volume, while application of bulky DSC significantly reduced total P transfers by 70% compared with the control due to a reduced runoff volume. Treatment effects in each monitoring period were most pronounced in the first runoff event. Differences in the release of P from the different P sources were related to the amounts of P extracted by either water or sodium bicarbonate in the order TSP > LCS > LDS > DSC. The results suggest there is a lower risk of P transfer in land runoff following application of sludge compared with other agricultural P amendments at similar P rates.

  10. An International Survey of Industrial Applications of Formal Methods. Volume 2. Case Studies

    DTIC Science & Technology

    1993-09-30

    impact of the product on IBM revenues. 4. Error rates were claimed to be below industrial average and errors were minimal to fix. Formal methods, as...critical applications. These include: 3 I I International Survey of Industrial Applications 41 i) "Software failures, particularly under first use, seem...project to add improved modelling capability. I U International Survey of Industrial Applications 93 I Design and Implementation These products are being

  11. Validation of Student and Parent Report Data on the Basic Grant Application Form. Final Report. Volume II, Estimated Income: CRT Look-Up Study, Individual Case Follow-Up Study, IRS Sample Study.

    ERIC Educational Resources Information Center

    Novalis, Carol

    The use of estimated income to analyze financial need of applicants to the Basic Educational Opportunity Grant (BEOG) program was investigated. Attention was focused on: how well applicants estimate their income; reasons for errors in estimation, and whether applicants supplying income tax returns supply true versions. For 1,547 eligible BEOG…

  12. Analysis of volumetric response of pituitary adenomas receiving adjuvant CyberKnife stereotactic radiosurgery with the application of an exponential fitting model

    PubMed Central

    Yu, Yi-Lin; Yang, Yun-Ju; Lin, Chin; Hsieh, Chih-Chuan; Li, Chiao-Zhu; Feng, Shao-Wei; Tang, Chi-Tun; Chung, Tzu-Tsao; Ma, Hsin-I; Chen, Yuan-Hao; Ju, Da-Tong; Hueng, Dueng-Yuan

    2017-01-01

    Abstract Tumor control rates of pituitary adenomas (PAs) receiving adjuvant CyberKnife stereotactic radiosurgery (CK SRS) are high. However, there is currently no uniform way to estimate the time course of the disease. The aim of this study was to analyze the volumetric responses of PAs after CK SRS and investigate the application of an exponential decay model in calculating an accurate time course and estimation of the eventual outcome. A retrospective review of 34 patients with PAs who received adjuvant CK SRS between 2006 and 2013 was performed. Tumor volume was calculated using the planimetric method. The percent change in tumor volume and tumor volume rate of change were compared at median 4-, 10-, 20-, and 36-month intervals. Tumor responses were classified as: progression for >15% volume increase, regression for ≤15% decrease, and stabilization for ±15% of the baseline volume at the time of last follow-up. For each patient, the volumetric change versus time was fitted with an exponential model. The overall tumor control rate was 94.1% in the 36-month (range 18–87 months) follow-up period (mean volume change of −43.3%). Volume regression (mean decrease of −50.5%) was demonstrated in 27 (79%) patients, tumor stabilization (mean change of −3.7%) in 5 (15%) patients, and tumor progression (mean increase of 28.1%) in 2 (6%) patients (P = 0.001). Tumors that eventually regressed or stabilized had a temporary volume increase of 1.07% and 41.5% at 4 months after CK SRS, respectively (P = 0.017). The tumor volume estimated using the exponential fitting equation demonstrated high positive correlation with the actual volume calculated by magnetic resonance imaging (MRI) as tested by Pearson correlation coefficient (0.9). Transient progression of PAs post-CK SRS was seen in 62.5% of the patients receiving CK SRS, and it was not predictive of eventual volume regression or progression. A three-point exponential model is of potential predictive value according to relative distribution. An exponential decay model can be used to calculate the time course of tumors that are ultimately controlled. PMID:28121913

  13. Fifth Annual Workshop on Space Operations Applications and Research (SOAR 1991), volume 2

    NASA Technical Reports Server (NTRS)

    Krishen, Kumar (Editor)

    1992-01-01

    Papers given at the Space Operations and Applications Symposium, host by the NASA Johnson Space Center on July 9-11, 1991 are given. The technical areas covered included intelligent systems, automation and robotics, human factors and life sciences, and environmental interactions.

  14. Logistics of Oil Spill Dispersant Application. Volume I. Logistics-Related Properties of Oil Spill Dispersants.

    DOT National Transportation Integrated Search

    1982-11-01

    The use of chemicals for oil spill dispersal, while not presently widespread in the U.S., would have implications for the U.S. Coast Guard's Marine Environmental Protection program. This report explores the logistics of oil disperant application by t...

  15. CICS Region Virtualization for Cost Effective Application Development

    ERIC Educational Resources Information Center

    Khan, Kamal Waris

    2012-01-01

    Mainframe is used for hosting large commercial databases, transaction servers and applications that require a greater degree of reliability, scalability and security. Customer Information Control System (CICS) is a mainframe software framework for implementing transaction services. It is designed for rapid, high-volume online processing. In order…

  16. 46 CFR 197.501 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... GENERAL PROVISIONS Benzene § 197.501 Applicability. (a) Except for vessels satisfying paragraph (b) of... barges, that are carrying benzene or benzene containing liquids in bulk as cargo. (b) This subpart does not apply to vessels that are carrying only liquid cargoes containing less than 0.5% benzene by volume...

  17. 46 CFR 197.501 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... GENERAL PROVISIONS Benzene § 197.501 Applicability. (a) Except for vessels satisfying paragraph (b) of... barges, that are carrying benzene or benzene containing liquids in bulk as cargo. (b) This subpart does not apply to vessels that are carrying only liquid cargoes containing less than 0.5% benzene by volume...

  18. 46 CFR 197.501 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GENERAL PROVISIONS Benzene § 197.501 Applicability. (a) Except for vessels satisfying paragraph (b) of... barges, that are carrying benzene or benzene containing liquids in bulk as cargo. (b) This subpart does not apply to vessels that are carrying only liquid cargoes containing less than 0.5% benzene by volume...

  19. 46 CFR 197.501 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GENERAL PROVISIONS Benzene § 197.501 Applicability. (a) Except for vessels satisfying paragraph (b) of... barges, that are carrying benzene or benzene containing liquids in bulk as cargo. (b) This subpart does not apply to vessels that are carrying only liquid cargoes containing less than 0.5% benzene by volume...

  20. 46 CFR 197.501 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... GENERAL PROVISIONS Benzene § 197.501 Applicability. (a) Except for vessels satisfying paragraph (b) of... barges, that are carrying benzene or benzene containing liquids in bulk as cargo. (b) This subpart does not apply to vessels that are carrying only liquid cargoes containing less than 0.5% benzene by volume...

  1. 40 CFR 94.203 - Application for certification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 94.203 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... § 94.109(d) for Category 3 engines. Small-volume manufacturers may omit measurement and reporting of... application of the engine (e.g., used to propel planing vessels, use to propel vessels with variable-pitch...

  2. The View Finder: International Perspectives on Special Education Technology. Volume 3.

    ERIC Educational Resources Information Center

    Edyburn, Dave L.; And Others

    The four articles in this monograph present issues in the application of technology to special education from an international perspective. In the first chapter, "Augmentative and Alternative Communication Systems--Computer Applications for Individuals with Disabilities: An International Perspective," Richard Cardinali and George McMurdo…

  3. Latest medical applications of polypropylene.

    PubMed

    Van Lierde, Stijn

    2004-06-01

    PP volumes for use in medical applications increase every year for some obvious reasons. The polymer can be processed by practically all techniques and sterilisation and transparency processes, and its properties are continuously improved. Furthermore, it can replace many other materials, and is attractive from a cost and versatility perspective.

  4. 40 CFR 57.203 - Contents of the application.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... application shall also contain the following information: (1) A process flow diagram of the smelter, including current process and instrumentation diagrams for all processes or equipment which may emit or affect the... equipment (flow rates, temperature, volumes, compositions, and variations over time); and a list of all...

  5. 40 CFR 57.203 - Contents of the application.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... application shall also contain the following information: (1) A process flow diagram of the smelter, including current process and instrumentation diagrams for all processes or equipment which may emit or affect the... equipment (flow rates, temperature, volumes, compositions, and variations over time); and a list of all...

  6. 40 CFR 57.203 - Contents of the application.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... application shall also contain the following information: (1) A process flow diagram of the smelter, including current process and instrumentation diagrams for all processes or equipment which may emit or affect the... equipment (flow rates, temperature, volumes, compositions, and variations over time); and a list of all...

  7. 40 CFR 57.203 - Contents of the application.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... application shall also contain the following information: (1) A process flow diagram of the smelter, including current process and instrumentation diagrams for all processes or equipment which may emit or affect the... equipment (flow rates, temperature, volumes, compositions, and variations over time); and a list of all...

  8. Development of a low-volume sprayer for an unmanned autonomous helicopter

    USDA-ARS?s Scientific Manuscript database

    An UAV (Unmanned Aerial Vehicle) can fly over much smaller areas with much lower flight altitudes than conventional, piloted airplanes. In agriculture, UAVs have been mainly developed and used for chemical application and remote sensing. Application of fertilizers and chemicals is frequently needed ...

  9. Continuation of the compendium of applications technology satellite and communications technology satellite user experiments 1967-1977, volume 2. [bibliography

    NASA Technical Reports Server (NTRS)

    Engler, N. A.; Nash, J. F.; Strange, J. D.

    1978-01-01

    Approximately 453 reports, papers, and articles catalogued into an information retrieval system, covering communications experiments and demonstrations conducted, utilizing the Communications Technology Satellite and the Applications Technology Satellites 1, 3, 5, and 6 are listed.

  10. Boundary Element Method in a Self-Gravitating Elastic Half-Space and Its Application to Deformation Induced by Magma Chambers

    NASA Astrophysics Data System (ADS)

    Fang, M.; Hager, B. H.

    2014-12-01

    In geophysical applications the boundary element method (BEM) often carries the essential physics in addition to being an efficient numerical scheme. For use of the BEM in a self-gravitating uniform half-space, we made extra effort and succeeded in deriving the fundamental solution analytically in closed-form. A problem that goes deep into the heart of the classic BEM is encountered when we try to apply the new fundamental solution in BEM for deformation field induced by a magma chamber or a fluid-filled reservoir. The central issue of the BEM is the singular integral arising from determination of the boundary values. A widely employed technique is to rescale the singular boundary point into a small finite volume and then shrink it to extract the limits. This operation boils down to the calculation of the so-called C-matrix. Authors in the past take the liberty of either adding or subtracting a small volume. By subtracting a small volume, the C-matrix is (1/2)I on a smooth surface, where I is the identity matrix; by adding a small volume, we arrive at the same C-matrix in the form of I - (1/2)I. This evenness is a result of the spherical symmetry of Kelvin's fundamental solution employed. When the spherical symmetry is broken by gravity, the C-matrix is polarized. And we face the choice between right and wrong, for adding and subtracting a small volume yield different C-matrices. Close examination reveals that both derivations, addition and subtraction of a small volume, are ad hoc. To resolve the issue we revisit the Somigliana identity with a new derivation and careful step-by-step anatomy. The result proves that even though both adding and subtracting a small volume appear to twist the original boundary, only addition essentially modifies the original boundary and consequently modifies the physics of the original problem in a subtle way. The correct procedure is subtraction. We complete a new BEM theory by introducing in full analytical form what we call the singular stress tensor for the fundamental solution. We partition the stress tensor of the fundamental solution into a singular part and a regular part. In this way all singular integrals systematically shift into the easy singular stress tensor. Applications of this new BEM to deformation and gravitational perturbation induced by magma chambers of finite volume will be presented.

  11. Materials characterization of free volume and void properties by two-dimensional positron annihilation lifetime spectroscopy

    NASA Astrophysics Data System (ADS)

    Chen, Hongmin; Van Horn, J. David; Jean, Y. C.; Hung, Wei-Song; Lee, Kueir-Rarn

    2013-04-01

    Positron annihilation lifetime spectroscopy (PALS) has been widely used to determine the free volume and void properties in polymeric materials. Recently, a two dimensional positron annihilation lifetime spectroscopy (2DPALS) system has been developed for membrane applications. The system measures the coincident signals between the lifetime and the energy which could separate the 2γ and 3γ annihilations and improve the accuracy in the determination of the free volume and void properties. When 2D-PALS is used in coupling with a variable mono-energy slow positron beam, it could be applied to a variety of material characterization. Results of free volumes and voids properties in a multi-layer polymer membrane characterized using 2D-PALS are presented.

  12. Mars power system concept definition study. Volume 1: Study results

    NASA Technical Reports Server (NTRS)

    Littman, Franklin D.

    1994-01-01

    A preliminary top level study was completed to define power system concepts applicable to Mars surface applications. This effort included definition of power system requirements and selection of power systems with the potential for high commonality. These power systems included dynamic isotope, Proton Exchange Membrane (PEM) regenerative fuel cell, sodium sulfur battery, photovoltaic, and reactor concepts. Design influencing factors were identified. Characterization studies were then done for each concept to determine system performance, size/volume, and mass. Operations studies were done to determine emplacement/deployment maintenance/servicing, and startup/shutdown requirements. Technology development roadmaps were written for each candidate power system (included in Volume 2). Example power system architectures were defined and compared on a mass basis. The dynamic isotope power system and nuclear reactor power system architectures had significantly lower total masses than the photovoltaic system architectures. Integrated development and deployment time phasing plans were completed for an example DIPS and reactor architecture option to determine the development strategies required to meet the mission scenario requirements.

  13. Protein-surface interactions on stimuli-responsive polymeric biomaterials.

    PubMed

    Cross, Michael C; Toomey, Ryan G; Gallant, Nathan D

    2016-03-04

    Responsive surfaces: a review of the dependence of protein adsorption on the reversible volume phase transition in stimuli-responsive polymers. Specifically addressed are a widely studied subset: thermoresponsive polymers. Findings are also generalizable to other materials which undergo a similarly reversible volume phase transition. As of 2015, over 100,000 articles have been published on stimuli-responsive polymers and many more on protein-biomaterial interactions. Significantly, fewer than 100 of these have focused specifically on protein interactions with stimuli-responsive polymers. These report a clear trend of increased protein adsorption in the collapsed state compared to the swollen state. This control over protein interactions makes stimuli-responsive polymers highly useful in biomedical applications such as wound repair scaffolds, on-demand drug delivery, and antifouling surfaces. Outstanding questions are whether the protein adsorption is reversible with the volume phase transition and whether there is a time-dependence. A clear understanding of protein interactions with stimuli-responsive polymers will advance theoretical models, experimental results, and biomedical applications.

  14. AOIPS 3 User's guide. Volume 1: Overview and software utilization

    NASA Technical Reports Server (NTRS)

    Schotz, S. S.; Negri, A. J.; Robinson, W.

    1989-01-01

    This is Volume I of the Atmospheric and Oceanographic Information Processing System (AOIPS) User's Guide. AOIPS 3 is the version of the AOIPS software as of April 1989. The AOIPS software was developed jointly by the Goddard Space Flight Center and General Sciences Corporation. Volume 1 is intended to provide the user with an overall guide to the AOIPS system. It introduces the user to AOIPS system concepts, explains how programs are related and the necessary order of program execution, and provides brief descriptions derived from on-line help for every AOIPS program. It is intended to serve as a reference for information such as: program function, inmput/output variable descriptions, program limitations, etc. AOIPS is an interactive meteorological processing system with capabilities to ingest and analyze the many types of meteorological data. AOIPS includes several applications in areas of relevance to meteorological research. AOIPS is partitioned into four applications components: satellite data analysis, radar data analysis, aircraft data analysis, and utilities.

  15. LOGO Teaching Sequences on Numbers and Functions and Equations. Teacher's Text and Problems.

    ERIC Educational Resources Information Center

    Grant, Richard; And Others

    The teacher's texts for two teaching sequences in the LOGO mathematics course are presented in this second volume of a four-volume report. The material presented here is designed to be a broad overview of the application of LOGO to the topics of numbers and functions. A variety of alternative paths and approaches are presented; in each case the…

  16. Use of small volume cups in XRF analysis of treated wood retention

    Treesearch

    Rene Stelzer; Adam Taylor; Patricia Lebow

    2017-01-01

    Efforts are underway in the United States to improve the conformance of commercially-treated wood with the applicable retention standards. As part of an effort to devise a practical method for on-site assessment of within-charge retention variation, we investigated whether small-volume x-ray fluorescence (XRF) sample cups could be used with treated wood. A range of cup...

  17. Volume, Mass, And Nutrients Of Down Woody Debris Following Initial Shortleaf Pine-Bluestem Grass Restoration Activities In The Ouachita Mountains Of Arkansas

    Treesearch

    Jessica C. Seifert; Hal O. Liechty; Martin A. Spetich; Daniel A. Marion

    2004-01-01

    Abstract - The Ouachita National Forest is restoring pine-mixed hardwood forests to a shortleaf pine-bluestem grass ecosystem through harvesting, midstory control, and the application of prescribed fire. Mean mass and volume of downed woody debris (DWD) in plots following initial harvesting and midstory-control were respectively 335 percent and 253...

  18. Weightless Environment Training Facility (WETF) materials coating evaluation, volume 2

    NASA Technical Reports Server (NTRS)

    1995-01-01

    This volume consists of Appendices A and B to the report on the Weightless Environment Training Facility Materials Coating Evaluation project. The project selected 10 coating systems to be evaluated in six separate exposure environments, and subject to three tests for physical properties. Appendix A holds the coating system, surface preparation, and application data. Appendix B holds the coating material infrared spectra.

  19. Long-term growth response of Douglas-fir to ammonium nitrate fertilizer.

    Treesearch

    Richard E. Miller; Robert F. Tarrant

    1983-01-01

    The effect of a single application of ammonium nitrate fertilizer on diameter, height, and volume growth of a Site IV plantation of Pseudotsuga menziesii was measured repeatedly during a 15-year period. Fertilizer dosages of 157, 314, and 471 kg N/ha increased gross volume growth during the 15-year period by an average of 5 I, 88, and 111 percent,...

  20. Predictive Flow Control to Minimize Convective Time Delays

    DTIC Science & Technology

    2013-08-19

    simulation. The CFO solver used is Cobalt, an unstructured finite-volume code developed for the solution of the compress- ible Navier-Stokes...cell-centered fin ite volume approach applicable to arbitrary cell topologies (e.g, hexahedra, prisms, tetrahedra). The spatial operator uses a Riemann ... solver , least squares gradient calculations using QR factorizati on to provide second order accuracy in space. A point implicit method using

  1. New PDLC materials obtained from dispersion of LC under microgravity

    NASA Astrophysics Data System (ADS)

    Matos, M. R.; Leitao, J. C.; Andre, R. M.; Zambujal, R.; Carmelo Rosa, Carla; Simeao Carvalho, P.; Podgorski, Thomas

    Aknowledgements: This project has been supported by ESA-Education, the University of Porto, IFIMUP and INESC-Porto. Bibliography: [1] F Bloisi and L Vicari. Optical Applications of Liquid Crystals, chapter 4: Polymer-dispersed liquid crystals. Institute of Physics Publishing, 2003. [2] J. William Doane. Liquid Crystals Applications and Uses, volume 1, chapter 14: Polymer Dispersed Liquid Crystal Displays, pages 361-391. World Scientific, 1990. [3] K. Parbhakar, J. M. Jin, H. M. Nguyen, and L. H. Dao. Effect of microgravity on the distribution of liquid-crystal droplets dispersed in a polymer matrix. CHEMISTRY OF MA-TERIALS, 8(??):1210-1216, Jun 1996. [4] Paul S. Drzaic. Liquid Crystal Dispersions, volume 1. World Scientific, 1995.

  2. Proceedings of the American Power Conference. Volume 58-I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McBride, A.E.

    1996-10-01

    This is volume 58-I of the proceedings of the American Power Conference, 1996, Technology for Competition and Globalization. The topics of the papers include power plant DC issues; cost of environmental compliance; advanced coal systems -- environmental performance; technology for competition in dispersed generation; superconductivity technologies for electric utility applications; power generation trends and challenges in China; aging in nuclear power plants; innovative and competitive repowering options; structural examinations, modifications and repairs; electric load forecasting; distribution planning; EMF effects; fuzzy logic and neural networks for power plant applications; electrokinetic decontamination of soils; integrated gasification combined cycle; advances in fusion; coolingmore » towers; relays; plant controls; flue gas desulfurization; waste product utilization; and improved technologies.« less

  3. The Implementation of Cumulative Learning Theory in Calculating Triangular Prism and Tube Volumes

    NASA Astrophysics Data System (ADS)

    Muklis, M.; Abidin, C.; Pamungkas, M. D.; Masriyah

    2018-01-01

    This study aims at describing the application of cumulative learning theory in calculating the volume of a triangular prism and a tube as well as revealing the students’ responses toward the learning. The research method used was descriptive qualitative with elementary school students as the subjects of the research. Data obtained through observation, field notes, questionnaire, tests, and interviews. The results from the application of cumulative learning theory obtained positive students’ responses in following the learning and students’ learning outcomes was dominantly above the average. This showed that cumulative learning could be used as a reference to be implemented in learning, so as to improve the students’ achievement.

  4. Development of Electrochemical Supercapacitors for EMA Applications

    NASA Technical Reports Server (NTRS)

    Kosek, John A.; Dunning, Thomas; LaConti, Anthony B.

    1996-01-01

    A limitation of the typical electrochemical capacitor is the maximum available power and energy density, and an improvement in capacitance per unit weight and volume is needed. A solid-ionomer electrochemical capacitor having a unit cell capacitance greater than 2 F/sq cm and a repeating element thickness of 6 mils has been developed. This capacitor could provide high-current pulses for electromechanical actuation (EMA). Primary project objectives were to develop high-capacitance particulates, to increase capacitor gravimetric and volumetric energy densities above baseline and to fabricate a 10-V capacitor with a repeating element thickness of 6 mils or less. Specific EMA applications were identified and capacitor weight and volume projections made.

  5. Directionally solidified iron-base eutectic alloys

    NASA Technical Reports Server (NTRS)

    Tewari, S. N.

    1976-01-01

    Pseudobinary eutectic alloys with nominal compositions of Fe-25Ta-22Ni-10Cr and Fe-15.5Nb-14.5Ni-6.0Cr were directionally solidified at 0.5 centimeter per hour. Their microstructure consisted of the fcc, iron solid-solution, matrix phase reinforced by about 41-volume-percent, hcp, faceted Fe2Ta fibers and 41-volume-percent, hcp, Fe2Nb lamellae for the tantalum- and niobium-containing alloys, respectively. The microstructural stability under thermal cycling and the temperature dependence of tensile properties were investigated. These alloys showed low elevated-temperature strength and were not considered suitable for application in aircraft-gas-turbine blades although they may have applicability as vane materials.

  6. Light clusters in nuclear matter: Excluded volume versus quantum many-body approaches

    NASA Astrophysics Data System (ADS)

    Hempel, Matthias; Schaffner-Bielich, Jürgen; Typel, Stefan; Röpke, Gerd

    2011-11-01

    The formation of clusters in nuclear matter is investigated, which occurs, e.g., in low-energy heavy-ion collisions or core-collapse supernovae. In astrophysical applications, the excluded volume concept is commonly used for the description of light clusters. Here we compare a phenomenological excluded volume approach to two quantum many-body models, the quantum statistical model and the generalized relativistic mean-field model. All three models contain bound states of nuclei with mass number A≤4. It is explored to which extent the complex medium effects can be mimicked by the simpler excluded volume model, regarding the chemical composition and thermodynamic variables. Furthermore, the role of heavy nuclei and excited states is investigated by use of the excluded volume model. At temperatures of a few MeV the excluded volume model gives a poor description of the medium effects on the light clusters, but there the composition is actually dominated by heavy nuclei. At larger temperatures there is a rather good agreement, whereas some smaller differences and model dependencies remain.

  7. Pressure-volume characteristics of dielectric elastomer diaphragms

    NASA Astrophysics Data System (ADS)

    Tews, Alyson M.; Pope, Kimberly L.; Snyder, Alan J.

    2003-07-01

    With the ultimate goal of constructing diaphragm-type pumps, we have measured pressure-volume characteristics of single-layer dielectric elastomers diaphragms. Circular dielectric elastomer diaphragms were prepared by biaxial stretching of 3M VHB 4905 polyacrylate, or spin casting and modest or no biaxial stretching of silicone rubber films, followed by mounting to a sealed chamber having a 3.8 cm diameter opening. Pressure-volume characteristics were measured at voltages that provided field strengths up to 80 MV/m in un-deformed VHB films and 50-75 MV/m in silicone films. The most highly pre-strained VHB diaphragms were found to have linear pressure-volume characteristics whose slopes (diaphragm compliance) depended sensitively upon applied field at higher field strengths. Compliance of unstretched silicone diaphragms was nearly independent of field strength at the fields tested, but pressure-volume characteristics shifted markedly. For both kinds of dielectric elastomers, pressure-volume work loops of significant size can be obtained for certain operating pressures. Each type of diaphragm may have advantages in certain applications.

  8. VOFTools - A software package of calculation tools for volume of fluid methods using general convex grids

    NASA Astrophysics Data System (ADS)

    López, J.; Hernández, J.; Gómez, P.; Faura, F.

    2018-02-01

    The VOFTools library includes efficient analytical and geometrical routines for (1) area/volume computation, (2) truncation operations that typically arise in VOF (volume of fluid) methods, (3) area/volume conservation enforcement (VCE) in PLIC (piecewise linear interface calculation) reconstruction and(4) computation of the distance from a given point to the reconstructed interface. The computation of a polyhedron volume uses an efficient formula based on a quadrilateral decomposition and a 2D projection of each polyhedron face. The analytical VCE method is based on coupling an interpolation procedure to bracket the solution with an improved final calculation step based on the above volume computation formula. Although the library was originally created to help develop highly accurate advection and reconstruction schemes in the context of VOF methods, it may have more general applications. To assess the performance of the supplied routines, different tests, which are provided in FORTRAN and C, were implemented for several 2D and 3D geometries.

  9. Data catalog series for space science and applications flight missions. Volume 6: Master index volume

    NASA Technical Reports Server (NTRS)

    Horowitz, Richard; Ross, Patricia A.; King, Joseph H.

    1989-01-01

    The main purpose of the data catalog series is to provide descriptive references to data generated by space science flight missions. The data sets described include all of the actual holdings of the Space Science Data Center (NSSDC), all data sets for which direct contact information is available, and some data collections held and serviced by foreign investigators, NASA, and other U.S. government agencies. This volume contains the Master Index. The following spacecraft are included: Mariner, Pioneer, Pioneer Venus, Venera, Viking, Voyager, and Helios. Separate indexes to the planetary and interplanetary missions are also provided.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez-Sprinberg, G; Piriz, G

    Purpose: To optimize the dose in bladder and rectum and show the different shapes of the isodose volumes in Co60-HDR brachytherapy, considering different utero and vaginal sources dwell ratio times (TU:TV). Methods: Besides Ir192-HDR, new Co60-HDR sources are being incorporated. We considered different TU:TV times and computed the dosis in bladder, rectum and at the reference points of the Manchester system. Also, we calculated the isodose volume and shape in each case. We used a EZAG-BEBIG Co0.A86 model with TPS HDRplus3.0.4. and LCT42-7, LCT42-2(R,L) applicators. A reference dose RA= 1.00 Gy was given to the A-right point. We considered themore » TU:TV dwell time ratios 1:0.25, 1:0.33, 1:0.5, 1:1, 1:2, 1:3, and 1:4. Given TU:TV, the stop time at each dwell position is fixed for each applicator. Results: Increasing TU:TV systematically results in a decreasing of the dose in bladder and rectum, e.g. 9% and 27% reduction were found in 1:0.25 with respect to 1:1, while 12% and 34% increase were found in 1:4 with respect to 1:1. Also, the isodose volume parameters height (h), width (w), thickness (t) and volume (hwt) increased from the 1:0.25 case to the 1:4 value: hwt is 25% lower and 31% higher than the 1:1 reference volume in these cases. Also w decreased for higher TU:TV and may compromise the tumoral volume coverage, decreasing 17% in the 1:0.25 case compared to the 1:1 case. The shape of the isodose volume was obtained for the different TU:TV considered. Conclusion: We obtained the shape of isodose volumes for different TU:TV values in gynecological Co60-HDR. We studied the dose reduction in bladder and rectum for different TU:TV ratios. The volume parameters and hwt are strongly dependent on this ratio. This information is useful for a quantitative check of the TPS and as a starting point towards optimization.« less

  11. A modified ATI technique for nowcasting convective rain volumes over areas. [area-time integrals

    NASA Technical Reports Server (NTRS)

    Makarau, Amos; Johnson, L. Ronald; Doneaud, Andre A.

    1988-01-01

    This paper explores the applicability of the area-time-integral (ATI) technique for the estimation of the growth portion only of a convective storm (while the rain volume is computed using the entire life history of the event) and for nowcasting the total rain volume of a convective system at the stage of its maximum development. For these purposes, the ATIs were computed from the digital radar data (for 1981-1982) from the North Dakota Cloud Modification Project, using the maximum echo area (ATIA) no less than 25 dBz, the maximum reflectivity, and the maximum echo height as the end of the growth portion of the convective event. Linear regression analysis demonstrated that correlations between total rain volume or the maximum rain volume versus ATIA were the strongest. The uncertainties obtained were comparable to the uncertainties which typically occur in rain volume estimates obtained from radar data employing Z-R conversion followed by space and time integration. This demonstrates that the total rain volume of a storm can be nowcasted at its maximum stage of development.

  12. Free volume of mixed cation borosilicate glass sealants elucidated by positron annihilation lifetime spectroscopy and its correlation with glass properties

    NASA Astrophysics Data System (ADS)

    Ojha, Prasanta K.; Rath, Sangram K.; Sharma, Sandeep K.; Sudarshan, Kathi; Pujari, Pradeep K.; Chongdar, Tapas K.; Gokhale, Nitin M.

    2015-01-01

    The role of La+3/Sr+2 ratios, which is varied from 0.08 to 5.09, on density, molar volume, packing fraction, free volume, thermal and electrical properties in strontium lanthanum aluminoborosilicate based glass sealants intended for solid oxide fuel cell (SOFC) applications is evaluated. The studies reveal expansion of the glass network evident from increasing molar volume and decreasing packing fraction of glasses with progressive La+3 substitutions. The molecular origin of these macroscopic structural features can be accounted for by the free volume parameters measured from positron annihilation lifetime spectroscopy (PALS). The La+3 induced expanded glass networks show increased number of subnanoscopic voids with larger sizes, as revealed from the ortho-positronium (o-Ps) lifetime and its intensity. A remarkably direct correspondence between the molar volume and fractional free volume trend is established with progressive La2O3 substitution in the glasses. The effect of these structural changes on the glass transition temperature, softening temperature, coefficient of thermal expansion, thermal stability as well as electrical conductivity has been studied.

  13. Architectural and Behavioral Systems Design Methodology and Analysis for Optimal Habitation in a Volume-Limited Spacecraft for Long Duration Flights

    NASA Technical Reports Server (NTRS)

    Kennedy, Kriss J.; Lewis, Ruthan; Toups, Larry; Howard, Robert; Whitmire, Alexandra; Smitherman, David; Howe, Scott

    2016-01-01

    As our human spaceflight missions change as we reach towards Mars, the risk of an adverse behavioral outcome increases, and requirements for crew health, safety, and performance, and the internal architecture, will need to change to accommodate unprecedented mission demands. Evidence shows that architectural arrangement and habitability elements impact behavior. Net habitable volume is the volume available to the crew after accounting for elements that decrease the functional volume of the spacecraft. Determination of minimum acceptable net habitable volume and associated architectural design elements, as mission duration and environment varies, is key to enabling, maintaining, andor enhancing human performance and psychological and behavioral health. Current NASA efforts to derive minimum acceptable net habitable volumes and study the interaction of covariates and stressors, such as sensory stimulation, communication, autonomy, and privacy, and application to internal architecture design layouts, attributes, and use of advanced accommodations will be presented. Furthermore, implications of crew adaptation to available volume as they transfer from Earth accommodations, to deep space travel, to planetary surface habitats, and return, will be discussed.

  14. METCAN simulation of candidate metal matrix composites for high temperature applications

    NASA Technical Reports Server (NTRS)

    Lee, Ho-Jun

    1990-01-01

    The METCAN (Metal Matrix Composite Analyzer) computer code is used to simulate the nonlinear behavior of select metal matrix composites in order to assess their potential for high temperature structural applications. Material properties for seven composites are generated at a fiber volume ratio of 0.33 for two bonding conditions (a perfect bond and a weak interphase case) at various temperatures. A comparison of the two bonding conditions studied shows a general reduction in value of all properties (except CTE) for the weak interphase case from the perfect bond case. However, in the weak interphase case, the residual stresses that develop are considerably less than those that form in the perfect bond case. Results of the computational simulation indicate that among the metal matrix composites examined, SiC/NiAl is the best candidate for high temperature applications at the given fiber volume ratio.

  15. Composite separators and redox flow batteries based on porous separators

    DOEpatents

    Li, Bin; Wei, Xiaoliang; Luo, Qingtao; Nie, Zimin; Wang, Wei; Sprenkle, Vincent L.

    2016-01-12

    Composite separators having a porous structure and including acid-stable, hydrophilic, inorganic particles enmeshed in a substantially fully fluorinated polyolefin matrix can be utilized in a number of applications. The inorganic particles can provide hydrophilic characteristics. The pores of the separator result in good selectivity and electrical conductivity. The fluorinated polymeric backbone can result in high chemical stability. Accordingly, one application of the composite separators is in redox flow batteries as low cost membranes. In such applications, the composite separator can also enable additional property-enhancing features compared to ion-exchange membranes. For example, simple capacity control can be achieved through hydraulic pressure by balancing the volumes of electrolyte on each side of the separator. While a porous separator can also allow for volume and pressure regulation, in RFBs that utilize corrosive and/or oxidizing compounds, the composite separators described herein are preferable for their robustness in the presence of such compounds.

  16. Development of Thin Solar Cells for Space Applications at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Dickman, John E.; Hepp, Aloysius; Banger, Kulbinder K.; Harris, Jerry D.; Jin, Michael H.

    2003-01-01

    NASA GRC Thin Film Solar Cell program is developing solar cell technologies for space applications which address two critical metrics: higher specific power (power per unit mass) and lower launch stowed volume. To be considered for space applications, an array using thin film solar cells must offer significantly higher specific power while reducing stowed volume compared to the present technologies being flown on space missions, namely crystalline solar cells. The NASA GRC program is developing single-source precursors and the requisite deposition hardware to grow high-efficiency, thin-film solar cells on polymer substrates at low deposition temperatures. Using low deposition temperatures enables the thin film solar cells to be grown on a variety of polymer substrates, many of which would not survive the high temperature processing currently used to fabricate thin film solar cells. The talk will present the latest results of this research program.

  17. Evaluation of the efficacy of lambda-cyhalothrin applied as ultra-low volume and thermal fog for emergency control of Aedes aegypti in Honduras.

    PubMed

    Perich, M J; Sherman, C; Burge, R; Gill, E; Quintana, M; Wirtz, R A

    2001-12-01

    An extended-duration formulation of lambda-cyhalothrin (Demand CS) applied as either an ultra-low volume (ULV) or thermal fog spray from a new handheld sprayer (Terrier) against Aedes aegypti was evaluated in Honduras. Spray applications were made at the front door for 1 min or to each room for 15 sec, both for the ULV and thermal fog applications to houses in separate blocks for each treatment. The efficacy and duration of effectiveness of the spray was determined from sentinel caged mosquito mortality and collection of mosquitoes within houses with a backpack power aspirator. Sentinel caged mosquito mortality in both open and sequestered locations was 97-100% for all spray treatments, with control mortality less than 2%. Both ULV applications (front door and each room) provided 4 wk of significant control (P < 0.01) based on adult Ae. aegypti house collections.

  18. Flexible holey graphene paper electrodes with enhanced rate capability for energy storage applications.

    PubMed

    Zhao, Xin; Hayner, Cary M; Kung, Mayfair C; Kung, Harold H

    2011-11-22

    The unique combination of high surface area, high electrical conductivity and robust mechanical integrity has attracted great interest in the use of graphene sheets for future electronics applications. Their potential applications for high-power energy storage devices, however, are restricted by the accessible volume, which may be only a fraction of the physical volume, a consequence of the compact geometry of the stack and the ion mobility. Here we demonstrated that remarkably enhanced power delivery can be realized in graphene papers for the use in Li-ion batteries by controlled generation of in-plane porosity via a mechanical cavitation-chemical oxidation approach. These flexible, holey graphene papers, created via facile microscopic engineering, possess abundant ion binding sites, enhanced ion diffusion kinetics, and excellent high-rate lithium-ion storage capabilities, and are suitable for high-performance energy storage devices. © 2011 American Chemical Society

  19. Ground Operations Aerospace Language (GOAL). Volume 5: Application Studies

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The Ground Operations Aerospace Language (GOAL) was designed to be used by test oriented personnel to write procedures which would be executed in a test environment. A series of discussions between NASA LV-CAP personnel and IBM resulted in some peripheral tasks which would aid in evaluating the applicability of the language in this environment, and provide enhancement for future applications. The results of these tasks are contained within this volume. The GOAL vocabulary provides a high degree of readability and retainability. To achieve these benefits, however, the procedure writer utilizes words and phrases of considerable length. Brief form study was undertaken to determine a means of relieving this burden. The study resulted in a version of GOAL which enables the writer to develop a dialect suitable to his needs and satisfy the syntax equations. The output of the compiler would continue to provide readability by printing out the standard GOAL language. This task is described.

  20. Proceedings of the Eleventh International Symposium on Remote Sensing of Environment, volume 2. [application and processing of remotely sensed data

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Application and processing of remotely sensed data are discussed. Areas of application include: pollution monitoring, water quality, land use, marine resources, ocean surface properties, and agriculture. Image processing and scene analysis are described along with automated photointerpretation and classification techniques. Data from infrared and multispectral band scanners onboard LANDSAT satellites are emphasized.

Top